mibs/MIBS/bintec/BIANCA-BRICK-MIB
2023-12-05 12:25:34 +01:00

3019 lines
90 KiB
Plaintext

-- This file is corresponding to Release 10.2.3.100 from 2018/07/18 00:00:00
-- (C)opyright 1991-2017 bintec elmeg GmbH, All Rights Reserved
-- $Revision: 1.56.1.2 $
BIANCA-BRICK-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, Unsigned32, Counter32, Gauge32, Counter64,
IpAddress, TimeTicks, mib-2, enterprises
FROM SNMPv2-SMI
DisplayString, TimeStamp, TruthValue
FROM SNMPv2-TC
bintec, bibo, sys, Date, HexValue
FROM BINTEC-MIB
TRAP-TYPE
FROM RFC-1215
sysDescr, sysName
FROM SNMPv2-MIB
;
biboMIB MODULE-IDENTITY
LAST-UPDATED "201703240000Z"
ORGANIZATION
"bintec elmeg GmbH"
CONTACT-INFO
"EMail: info@bintec-elmeg.com
Web: www.bintec-elmeg.com
"
DESCRIPTION
"MIB module for vendor specific box definitions.
Note: bibo stands for BinTec box stemming from the times where
the company was still called BinTec."
REVISION "201004280000Z"
DESCRIPTION
"First version conforming to SMIv2."
::= { bintec 250 }
-- This MIB module uses the extended OBJECT-TYPE macro as
-- defined in [14];
-- MIB-II (same prefix as MIB-I)
admin OBJECT IDENTIFIER
::= { bibo 1 }
-- Some variables for administration of the BIANCA/BRICK
-- biboAdmTrapCommunity OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..255))
-- MAX-ACCESS read-write
-- STATUS mandatory
-- - BINTEC NOTRAP
-- DESCRIPTION
-- "Community name for sending traps."
-- DEFVAL { "snmp-Trap" }
-- ::= { admin 4 }
--
-- biboAdmSnmpVersion OBJECT-TYPE
-- SYNTAX INTEGER { version1(1),
-- version1-compat(2),
-- version1p1(3),
-- version1p1-compat(4),
-- version1p1-auto(5)
-- }
-- MAX-ACCESS read-write
-- STATUS mandatory
--
-- DESCRIPTION
-- "SNMP Version.
-- version1 : SNMP version V1
-- version1_compat : SNMP version V1 compatibility mode
-- without the appending private OID
-- part (.i). This is for some SNMP managers
-- that cannot handle this extension.
-- In this mode rows with identical
-- index variable content cannot be read
-- correctly.
-- p1 (patch1) : getnext returns the lexicographical next
-- OID (ever!)
-- version1p1_auto : use version1p1_compat if possible
-- use version1p1 if nessesary
--
-- Usually the OIDs have the format:
-- .1.3.6.x.x .y.y .i
--
-- .1.3.6.x.x: is the constant part of the OID of the
-- variable specified in MIB-source
-- .y.y : is the specific part of the OID to identify
-- exactly a row.
-- It is the content of all index variables.
-- .i : is a consecutively incremented index number,
-- to distinguish rows with identical index variables
-- "
-- DEFVAL { version1p1-auto }
-- ::= { admin 5 }
--
-- biboAdmSnmpPort OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
--
-- DESCRIPTION
-- "SNMP listen port."
-- DEFVAL { 161 }
-- ::= { admin 6 }
--
-- biboAdmSnmpTrapPort OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- - BINTEC NOTRAP
-- DESCRIPTION
-- "SNMP trap port."
-- DEFVAL { 162 }
-- ::= { admin 7 }
biboAdmIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Local IP address. If this object is set, it's value will be
used as the source address for all IP packets that are sent.
Otherwise, the IP address used will be retrieved from the
ipRouteTable, for the interface the IP packet is to be
transmitted over."
::= { admin 8 }
-- biboAdmTrapBrdCast OBJECT-TYPE
-- SYNTAX INTEGER { on(1), off(2) }
-- MAX-ACCESS read-write
-- STATUS current
-- - BINTEC NOTRAP
-- DESCRIPTION
-- "Enable/disable trap broadcasting."
-- DEFVAL { off }
-- ::= { admin 9 }
biboAdmTrapHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF BiboAdmTrapHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The biboAdmTrapHostTable defines where traps are sent
(i.e., which hosts). If the table is empty traps are
broadcasted.
Creating entries: Entries are added by assigning an IP
address value to the biboAdmTrapHostAddr field.
Deleting entries: Entries can be removed by assigning
ing the respective biboAdmTrapHostStatus field to
'delete'."
::= { admin 10 }
biboAdmTrapHostEntry OBJECT-TYPE
SYNTAX BiboAdmTrapHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { biboAdmTrapHostAddr }
::= { biboAdmTrapHostTable 1 }
BiboAdmTrapHostEntry ::= SEQUENCE {
biboAdmTrapHostAddr IpAddress,
biboAdmTrapHostStatus INTEGER
}
biboAdmTrapHostAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ip-Address where traps are sent."
::= { biboAdmTrapHostEntry 1 }
biboAdmTrapHostStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
delete(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Status is always valid, and set to delete only to discard
the whole entry."
DEFVAL { valid }
::= { biboAdmTrapHostEntry 2 }
biboAdmSyslogMaxEntries OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum Number of syslog messages stored in memory."
DEFVAL { 20 }
::= { admin 11 }
biboAdmSyslogTable OBJECT-TYPE
SYNTAX SEQUENCE OF BiboAdmSyslogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The biboAdmSyslogTable keeps track of syslog messages
received. The size of the table (number of entries), is
limited by the value of biboAdmSyslogMaxEntries. The
columns specify attributes for each message generated. As
this information only reports events on the system, all
fields are read-only.
Creating entries: Entries can only be created by the
system and are made each time a syslog message is
generated.
Deleting entries: Entries are removed by the system
once the size limit (biboAdmSyslogMaxEntries) is reached."
::= { admin 12 }
biboAdmLogHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF BiboAdmLogHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The biboAdmLogHostTable lists hosts which are to
receive syslog messages. This table also defines which
types and levels of messages to send.
Creating entries: Entries are created by setting a IP address
to biboAdmLogHostAddr.
Deleting entries: Entries are removed by setting the
appropriate biboAdmLogHostLevel field to 'delete'."
::= { admin 13 }
biboAdmLogHostEntry OBJECT-TYPE
SYNTAX BiboAdmLogHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { biboAdmLogHostAddr }
::= { biboAdmLogHostTable 1 }
BiboAdmLogHostEntry ::= SEQUENCE {
biboAdmLogHostAddr IpAddress,
biboAdmLogHostLevel INTEGER,
biboAdmLogHostFacility INTEGER,
biboAdmLogHostType INTEGER,
biboAdmLogHostTimestamp INTEGER,
biboAdmLogHostMethod INTEGER
}
biboAdmLogHostAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ip-Address where syslog messages are sent. If the
facility is set to memory or console, this field is
not used."
::= { biboAdmLogHostEntry 1 }
biboAdmLogHostLevel OBJECT-TYPE
SYNTAX INTEGER {
emerg(1),
alert(2),
crit(3),
err(4),
warning(5),
notice(6),
info(7),
debug(8),
delete(9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priorities lower or equal this level are sent to loghost.
The delete priority is used to discard the whole entry."
DEFVAL { info }
::= { biboAdmLogHostEntry 2 }
biboAdmLogHostFacility OBJECT-TYPE
SYNTAX INTEGER {
local0(1),
local1(2),
local2(3),
local3(4),
local4(5),
local5(6),
local6(7),
local7(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The facility used for the syslog messages being generated."
DEFVAL { local0 }
::= { biboAdmLogHostEntry 4 }
biboAdmLogHostType OBJECT-TYPE
SYNTAX INTEGER {
system(1),
acct(2),
all(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The subject of the messages that are to be generated. system
means all subjects except accounting, all means all subjects."
DEFVAL { all }
::= { biboAdmLogHostEntry 5 }
biboAdmLogHostTimestamp OBJECT-TYPE
SYNTAX INTEGER {
none(1),
time(2),
all(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object describes the format of the timestamp.
none(1) = no timestamp,
time(2) = only time is printed,
all(3) = date and time is printed."
DEFVAL { none }
::= { biboAdmLogHostEntry 6 }
biboAdmLogHostMethod OBJECT-TYPE
SYNTAX INTEGER {
udp(1),
tcp(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object provides protocol for sending syslog messages:
udp(1) = udp
tcp(2) = tcp
"
DEFVAL { udp }
::= { biboAdmLogHostEntry 7 }
-- Configuration
biboAdmConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF BiboAdmConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The biboAdmConfigTable is used for assigning
parameters for managing configuration files.
Creating entries: Entries are added to this table by
assigning a value to the biboAdmConfigCmd object. (i.e., The
intermediate result of executing, cmd=save, creates an
entry to this table.).
Deleting entries: Entries can only be removed by the
system and is done only after the requested action has
been performed (i.e. Once the cmd=save action is
complete.)."
::= { admin 14 }
biboAdmConfigEntry OBJECT-TYPE
SYNTAX BiboAdmConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { biboAdmConfigCmd }
::= { biboAdmConfigTable 1 }
BiboAdmConfigEntry ::= SEQUENCE {
biboAdmConfigCmd INTEGER,
biboAdmConfigObject OBJECT IDENTIFIER,
biboAdmConfigPath DisplayString,
biboAdmConfigPathNew DisplayString,
biboAdmConfigHost IpAddress,
biboAdmConfigState INTEGER,
biboAdmConfigFile DisplayString,
biboAdmConfigTimeout INTEGER,
biboAdmConfigHostUrl DisplayString,
biboAdmConfigCertIndex INTEGER
}
biboAdmConfigDirTable OBJECT-TYPE
SYNTAX SEQUENCE OF BiboAdmConfigDirEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration directory table. This table contains
all available configuration files in flash memory."
::= { admin 15 }
biboAdmConfigDirEntry OBJECT-TYPE
SYNTAX BiboAdmConfigDirEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { biboAdmConfigDirName }
::= { biboAdmConfigDirTable 1 }
BiboAdmConfigDirEntry ::= SEQUENCE {
biboAdmConfigDirName DisplayString,
biboAdmConfigDirCount INTEGER,
biboAdmConfigDirContent DisplayString,
biboAdmConfigDirSaveDate DisplayString
}
biboAdmConfigCmd OBJECT-TYPE
SYNTAX INTEGER {
save(1),
load(2),
put(3),
get(4),
state(5),
delete(6),
move(7),
copy(8),
reboot(9),
reorg(10),
unload(11),
put-all(12),
get-all(13),
load-keep-certs(14),
load-from-default(15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Command for configuration handling. Possible values are :
save(1) = save configuration (to FLASH)
load(2) = load configuration (from FLASH)
put(3) = write configuration (via TFTP)
get(4) = read configuration (via TFTP)
state(5) = write complete configuration (via TFTP)
delete(6) = delete configuration (within FLASH)
move(7) = move configuration (within FLASH)
copy(8) = copy configuration (within FLASH)
reboot(9) = reboot the system
reorg(10) = reorganizes the flash
unload(11) = remove loaded configuration (from RAM)
put_all(12) = write configuration (via TFTP),
include not accessible variables
get_all(13) = read configuration (via TFTP),
including not accessible variables
load_keep_certs(14) = load configuration (from FLASH),
do not overwrite already loaded certificates
load-from-default(15) = load default configuration (from GENFILES)"
DEFVAL { save }
::= { biboAdmConfigEntry 1 }
biboAdmConfigObject OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Table object id (OID) to save/load. If this field is
set, only this table is saved/loaded. Otherwise all tables
are saved/loaded."
::= { biboAdmConfigEntry 2 }
biboAdmConfigPath OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"NAme of the configuration file in flash memory to save/load."
::= { biboAdmConfigEntry 3 }
biboAdmConfigPathNew OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"New name of configuration file in flash memory to move/copy"
::= { biboAdmConfigEntry 4 }
biboAdmConfigHost OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TFTP host's IP address to send/receive the file to/from.
The configuration is transfered directly from flash
memory (biboAdmConfigPath) to TFTP-file (biboAdmConfigFile)."
::= { biboAdmConfigEntry 5 }
biboAdmConfigState OBJECT-TYPE
SYNTAX INTEGER { todo(1), running(2), done(3), error(4),
delayed(5), stopped(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of this command (i.e., biboAdmConfigCmd).
todo(1) : the command will start soon
running(2) : the command is currently executing
done(3) : the command has successfully completed
error(4) : the command has failed (see biboAdmSyslogTable)
delayed(5) : the command is delayed due to given Timeout
stopped(6) : the command has stopped (Timeout set to -1)
"
DEFVAL { todo }
::= { biboAdmConfigEntry 6 }
biboAdmConfigFile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TFTP filename to read/write from/to the specified host.
The configuration file received is stored in flash memory
specified by biboAdmConfigPath.
The actual configuration is not changed."
::= { biboAdmConfigEntry 7 }
biboAdmConfigTimeout OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set this value (default 0) to delay a new command for this
amount of seconds.
The value is counting down to show the remaining time
(State=delayed).
To stop a scheduled but delayed command set this value
to -1.
timeout = 0 cmd executed immediately (default)
timeout > 0 cmd executed in timeout seconds (counting down)
timeout < 0 cmd execution stopped (deleted)
"
DEFVAL { 0 }
::= { biboAdmConfigEntry 8 }
biboAdmConfigHostUrl OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a host URL specifying the location to
retrieve or store the configuration file.
The last filename part must be missing and is given
in biboAdmConfigFile.
If this object is given biboAdmConfigHost is ignored.
format:
http://server/path/
tftp://server/path/
xmodem:[1k][@9600]
"
::= { biboAdmConfigEntry 9 }
biboAdmConfigCertIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The index of the certificate to use (from the certTable).
Only used for biboAdmConfigCmd = get / get-all and for
use with biboAdmConfigHostUrl, of course.
If set to 0, no client certificate is used.
Default value is 0."
DEFVAL { 0 }
::= { biboAdmConfigEntry 10 }
---
---
---
biboAdmConfigDirName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the configuration file in flash memory."
::= { biboAdmConfigDirEntry 1 }
biboAdmConfigDirCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of tables saved in the file."
::= { biboAdmConfigDirEntry 2 }
biboAdmConfigDirContent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of directory's contents (e.g., <all> or a
series of table numbers)."
::= { biboAdmConfigDirEntry 3 }
biboAdmConfigDirSaveDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Date when configuration was saved. It reflects value of
variable biboExtAdmConfigSaveDate which gets set when the
configuration is saved to flash.
This also means: if a configuration doesn't contain this
variable no date is available."
::= { biboAdmConfigDirEntry 4 }
-- Board Table
biboAdmBoardTable OBJECT-TYPE
SYNTAX SEQUENCE OF BiboAdmBoardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The biboAdmBoardTable lists information about the
installed communications modules. This table is updated
after every system boot up.
Creating entries: Entries are created by the system
upon detecting the installed hardware.
Deleting entries: Entries are removed by the system
as a result of removed hardware."
::= { admin 17 }
biboAdmBoardEntry OBJECT-TYPE
SYNTAX BiboAdmBoardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { biboABrdSlot, biboABrdUnit }
::= { biboAdmBoardTable 1 }
BiboAdmBoardEntry ::=
SEQUENCE {
biboABrdSlot INTEGER,
biboABrdType DisplayString,
biboABrdHWRelease DisplayString,
biboABrdFWRelease DisplayString,
biboABrdPartNo DisplayString,
biboABrdConnector INTEGER,
biboABrdUnit INTEGER,
biboABrdSerialNo DisplayString,
biboABrdCategory INTEGER
}
biboABrdSlot OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot, or location of this module."
::= { biboAdmBoardEntry 1 }
biboABrdType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of this module."
::= { biboAdmBoardEntry 2 }
biboABrdHWRelease OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hardware release of this module."
::= { biboAdmBoardEntry 3 }
biboABrdFWRelease OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The firmware release of this module."
::= { biboAdmBoardEntry 4 }
biboABrdPartNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part number of this module."
::= { biboAdmBoardEntry 5 }
biboABrdConnector OBJECT-TYPE
SYNTAX INTEGER { auto(1), rj45(2), bnc(3), subd15(4),
rj45-10mbit-hdup(5), rj45-10mbit-fdup(6),
rj45-100mbit-hdup(7), rj45-100mbit-fdup(8) }
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The type of connector used for this module. For
modules with more than one connector this value can be
changed/switched by setting this object. For example,
the CM-BNCTP module supports both twisted pair
(RJ45) and 10Base2 (BNC) connectors. If this object is set
to 'AUTO' then the BRICK will automatically detect
which connector type is being used."
::= { biboAdmBoardEntry 6 }
biboABrdUnit OBJECT-TYPE
SYNTAX INTEGER (0..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The logical unit number of this interface."
DEFVAL { 0 }
::= { biboAdmBoardEntry 7 }
biboABrdSerialNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of this module."
::= { biboAdmBoardEntry 8 }
biboABrdCategory OBJECT-TYPE
SYNTAX INTEGER {
system-board(1),
ethernet(2),
isdn-bri(3),
isdn-pmx(4),
pots(5),
dsl(6),
wlan(7),
tty(8),
dsp(9),
usb(10),
crypt(11),
mobile(12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board category. It can be one of the following:
system-board(1),
ethernet(2),
isdn-bri(3),
isdn-pmx(4),
pots(5),
dsl(6),
wlan(7),
tty(8),
dsp(9),
usb(10),
crypt(11),
mobile(12)
It advices users of which MIB table to look at when searching
for additional configuration informations."
::= { biboAdmBoardEntry 9 }
-- user defined traps
biboAdmUsrTrapTable OBJECT-TYPE
SYNTAX SEQUENCE OF BiboAdmUsrTrapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The biboAdmUsrTrapTable lists user-defined objects that
are used to create traps. These traps are sent locally, but
can also be sent to remote hosts using the
biboAdmTrapHostTable.
Creating entries: Entries are created by assigning the
biboATrpObj object a valid object identifier.
Deleting entries: Entries are removed by setting the
entry's biboATrpStatus object to 'delete'."
::= { admin 18 }
biboAdmUsrTrapEntry OBJECT-TYPE
SYNTAX BiboAdmUsrTrapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { biboATrpObj }
::= { biboAdmUsrTrapTable 1 }
BiboAdmUsrTrapEntry ::=
SEQUENCE {
biboATrpObj OBJECT IDENTIFIER,
biboATrpStatus INTEGER
}
biboATrpObj OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object identifier of an object to use. Each time this
object's value changes, a trap is created and sent. Either a
single leaf (single variable) or a table (of objects) can be
specified."
::= { biboAdmUsrTrapEntry 1 }
biboATrpStatus OBJECT-TYPE
SYNTAX INTEGER { valid(1), delete(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this entry. Upon creation of a new entry,
this object's value is set to 'valid'."
DEFVAL { valid }
::= { biboAdmUsrTrapEntry 2 }
biboAdmDomainName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Domain name."
DEFVAL { "" }
::= { admin 19 }
biboAdmNameServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of name server."
::= { admin 20 }
biboAdmNameServ2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of second name server."
::= { admin 21 }
biboAdmBridgeEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled (2) }
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Sets bridging to enable / disable status."
DEFVAL { enabled }
::= { admin 22 }
biboAdmCapiTcpPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TCP port for remote CAPI demon."
DEFVAL { 2662 }
::= { admin 23 }
biboAdmTraceTcpPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TCP port for trace demon."
DEFVAL { 7000 }
::= { admin 24 }
biboAdmRipUdpPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"UDP port for RIP. Setting this object
to zero disables RIP."
DEFVAL { 520 }
::= { admin 25 }
biboAdmSWVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the software release version. It's either identical to
biboAdmSWVersionOS or biboAdmSWVersionOEM."
::= { admin 26 }
biboAdmTimeServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address of the time server."
::= { admin 27 }
biboAdmTimeOffset OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the time offset from GMT in seconds.
If the set value is in the range from -24 to 24,
it means hours, and is automatically converted
to seconds."
DEFVAL { 0 }
::= { admin 28 }
biboAdmConsoleSyslog OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies whether to direct syslog messages to the
console."
DEFVAL { disable }
::= { admin 29 }
biboAdmSyslogTableLevel OBJECT-TYPE
SYNTAX INTEGER {
emerg(1),
alert(2),
crit(3),
err(4),
warning(5),
notice(6),
info(7),
debug(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies which message levels to post to the
biboAdmSyslogTable and the console, if applicable."
DEFVAL { info }
::= { admin 30 }
biboAdmSystemId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the system Identification String."
::= { admin 31 }
biboAdmLicInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF BiboAdmLicInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains an entry for each feature, that
can be activated by a license. The licenses have to
be entered in the biboAdmLicenseTable. This tabl
indicates the current state of the different licenses."
::= { admin 32 }
biboAdmLicInfoEntry OBJECT-TYPE
SYNTAX BiboAdmLicInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { biboAdmLicInfoType, biboAdmLicInfoStatus }
::= { biboAdmLicInfoTable 1 }
BiboAdmLicInfoEntry ::=
SEQUENCE {
biboAdmLicInfoType INTEGER,
biboAdmLicInfoStatus INTEGER,
biboAdmLicInfoId DisplayString,
biboAdmLicInfoSlot INTEGER,
biboAdmLicInfoMaxLic Counter32,
biboAdmLicInfoInUse Counter32,
biboAdmLicInfoHwSerial DisplayString,
biboAdmLicInfoUnit INTEGER,
biboAdmLicInfoLimit Counter32,
biboAdmLicInfoFree Counter32
}
biboAdmLicInfoType OBJECT-TYPE
SYNTAX INTEGER {
ip(1), capi(2), bridge(3), x25(4), ipx(5), stac(6),
frame-relay(7), tapi(8), ospf(9), extended-lan(10),
tunneling(11), taf(12), extended-wan(13), leased-line(14),
lcr(15),
app-power-phone(17), app-operator-desk(18),
app-voice-mail-server(19), app-accounting-tool(20),
app-intelligent-voice(21), app-6(22),
e25(29),
ipsec(33), ipseccb-ipxfer(34), bgp(35),
uefs(36), siplan(37), siptrunk(38), pim(39),
call-by-call(40), fax(41), sipout(42), brrp(43),
wlan-controller(44), terminal-option(45),
data-encr-accel(46), voice-mail-system(47), pptp(48),
ethernet(128), bri(129), g703(130), pri(131),
modem(132), g7032pri(133), slots(134), e3(135),
serial(136), shdsl(137), vdsl(138)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The licenseable feature."
::= { biboAdmLicInfoEntry 1 }
biboAdmLicInfoStatus OBJECT-TYPE
SYNTAX INTEGER {
builtin(1), valid-license(2), invalid-license(3), no-license(4),
erase-internal(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the license."
::= { biboAdmLicInfoEntry 2 }
biboAdmLicInfoId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The complete serial id string of the special license."
::= { biboAdmLicInfoEntry 3 }
biboAdmLicInfoSlot OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In case of a hardware license corresponding to a dedicated
module serial number, it is the slot number of the module."
::= { biboAdmLicInfoEntry 4 }
biboAdmLicInfoMaxLic OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of allowed chunks."
::= { biboAdmLicInfoEntry 5 }
biboAdmLicInfoInUse OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of chunks in use."
::= { biboAdmLicInfoEntry 6 }
biboAdmLicInfoHwSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The complete serial id string of the special license."
::= { biboAdmLicInfoEntry 7 }
biboAdmLicInfoUnit OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In case of a hardware license corresponding to a dedicated
module serial number, it is the unit number of the module."
::= { biboAdmLicInfoEntry 8 }
biboAdmLicInfoLimit OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of licenseable chunks."
::= { biboAdmLicInfoEntry 9 }
biboAdmLicInfoFree OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of free default licences."
::= { biboAdmLicInfoEntry 10 }
biboAdmBootpRelayServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the destination IP address to
which BOOTP/DHCP request are forwarded by the
BIANCA/BRICK BOOTP relay agent.
If this entry is empty no BOOTP forwarding is done."
::= { admin 33 }
biboAdmRadiusServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the IP address of the RADIUS
server (remote dial in user service). If set to 0.0.0.0
RADIUS services are generally disabled (default).
The corresponding Radius password is configured in the
biboAdmRadiusSecret variable."
::= { admin 34 }
biboAdmLocalPPPIdent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the local ID string used for PPP authentication
(PAP/CHAP). In pre4.3 versions the sysName has been used
as the local ID string. This is, for increased ease and
transparency of system configuration, no longer true."
DEFVAL { "" }
::= { admin 35 }
biboAdmHttpTcpPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TCP port for the HTTP server. Default port is 80, 0 disables
the HTTP server."
DEFVAL { 80 }
::= { admin 36 }
biboAdmTapiTcpPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TCP port for remote TAPI demon."
DEFVAL { 2663 }
::= { admin 37 }
biboAdmTimeProtocol OBJECT-TYPE
SYNTAX INTEGER {
none(1),
time-udp(2),
time-tcp(3),
time-sntp(4),
isdn(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field specifies from which source the bricks internal
clock is synchronised:
none(1) = no time synchronisation
time-udp(2) = UDP/TIME (RFC 868), from biboAdmTimeServer
time-tcp(3) = TCP/TIME (RFC 868), from biboAdmTimeServer
time-sntp(4) = SNTP (RFC 1769), from biboAdmTimeServer
isdn(5) = examines ISDN time, from controller stack 0"
DEFVAL { time-udp }
::= { admin 38 }
biboAdmTimeUpdate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the interval for timeserver requests (in seconds).
If the set value is in the range from -24 to 24,
it means hours, and is automatically converted
to seconds.
If the time comes from ISDN, the time is updated
with the next call after this interval."
DEFVAL { 24 }
::= { admin 39 }
biboAdmWINS1 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the WINS server (NetBIOS Name Server)."
::= { admin 40 }
biboAdmWINS2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the alternate WINS server."
::= { admin 41 }
admin-2 OBJECT IDENTIFIER
::= { bibo 22 }
-- Card Table
biboAdmCardTable OBJECT-TYPE
SYNTAX SEQUENCE OF BiboAdmCardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The biboAdmCardTable lists installed cards."
::= { admin 42 }
biboAdmCardEntry OBJECT-TYPE
SYNTAX BiboAdmCardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { biboACrdSlot }
::= { biboAdmCardTable 1 }
BiboAdmCardEntry ::=
SEQUENCE {
biboACrdSlot INTEGER,
biboACrdType DisplayString,
biboACrdState INTEGER,
biboACrdCpldVersion DisplayString,
biboACrdFpgaVersion DisplayString,
biboACrdTemp INTEGER,
biboACrdTempAlarmThreshold INTEGER,
biboACrdTempAlarmTrap INTEGER,
biboACrdAdmin INTEGER,
biboACrdTempAlarmThresholdCriticalLow INTEGER
}
biboACrdSlot OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot, or location of this card."
::= { biboAdmCardEntry 1 }
biboACrdType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of this card."
::= { biboAdmCardEntry 2 }
biboACrdState OBJECT-TYPE
SYNTAX INTEGER { down(1), running(2), fail(3), stopped(4),
stopping(5), starting (6) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the card."
DEFVAL { down }
::= { biboAdmCardEntry 3 }
biboACrdCpldVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Version of onboard CPLD."
::= { biboAdmCardEntry 4 }
biboACrdFpgaVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Version of loaded FPGA firmware."
::= { biboAdmCardEntry 5 }
biboACrdTemp OBJECT-TYPE
SYNTAX INTEGER (0..250)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable shows the actual card temperature
in the unit Celsius."
::= { biboAdmCardEntry 6 }
biboACrdTempAlarmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..250)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Card temperature threshold."
::= { biboAdmCardEntry 7 }
biboACrdTempAlarmTrap OBJECT-TYPE
SYNTAX INTEGER { normal(1), critical(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the card temperature raises above the threshold,
a trap is generated every 60 seconds."
::= { biboAdmCardEntry 8 }
biboACrdAdmin OBJECT-TYPE
SYNTAX INTEGER { up(1), down(2), reconfig(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative manipulation of card state."
::= { biboAdmCardEntry 9 }
biboACrdTempAlarmThresholdCriticalLow OBJECT-TYPE
SYNTAX INTEGER (0..250)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Lower Card temperature threshold to return state from critical
to normal. Mustn't exceed biboACrdTempAlarmThreshold!
When temperature reaches biboACrdTempAlarmThreshold state
changes to critical. This state persists until temperature
falls below biboACrdTempAlarmThreshUncriticalLow where state
changes back to normal."
::= { biboAdmCardEntry 10 }
biboAdmTraps OBJECT IDENTIFIER ::= { admin 43 }
biboAdmTrapACrdTempCritical TRAP-TYPE
ENTERPRISE biboAdmTraps
VARIABLES {
sysDescr,
sysName,
biboACrdSlot,
biboACrdType,
biboACrdState,
biboACrdTemp,
biboACrdTempAlarmThreshold
}
DESCRIPTION "This trap signifies that the Card temperature raises
above the critical alarm-threshold"
::= 1
biboAdmTrapACrdTempOk TRAP-TYPE
ENTERPRISE biboAdmTraps
VARIABLES {
sysDescr,
sysName,
biboACrdSlot,
biboACrdType,
biboACrdState,
biboACrdTemp,
biboACrdTempAlarmThreshold
}
DESCRIPTION "A normal Card temperature has been restored."
::= 2
biboAdmTrapACrdDown TRAP-TYPE
ENTERPRISE biboAdmTraps
VARIABLES {
sysDescr,
sysName,
biboACrdSlot,
biboACrdType,
biboACrdState,
biboACrdTemp
}
DESCRIPTION "This trap signifies that the specified Card is down"
::= 3
biboAdmTrapACrdRunning TRAP-TYPE
ENTERPRISE biboAdmTraps
VARIABLES {
sysDescr,
sysName,
biboACrdSlot,
biboACrdType,
biboACrdState,
biboACrdTemp
}
DESCRIPTION "This trap signifies that the specified Card
is up/running"
::= 4
biboAdmTrapACrdFailed TRAP-TYPE
ENTERPRISE biboAdmTraps
VARIABLES {
sysDescr,
sysName,
biboACrdSlot,
biboACrdType,
biboACrdState,
biboACrdTemp
}
DESCRIPTION "This trap signifies that the specified Card
has failed"
::= 5
biboAdmTrapACrdStopped TRAP-TYPE
ENTERPRISE biboAdmTraps
VARIABLES {
sysDescr,
sysName,
biboACrdSlot,
biboACrdType,
biboACrdState,
biboACrdTemp
}
DESCRIPTION "This trap signifies that the specified Card
is stopped"
::= 6
-- biboAdmSnmpLinkTrapEvent OBJECT-TYPE
-- SYNTAX INTEGER { none(1),
-- any(2),
-- up(3),
-- down(4)
-- }
-- MAX-ACCESS read-write
-- STATUS current
--
-- DESCRIPTION
-- "Defines the ifOperStatus transition(s) of an ifTable object
-- that generates a SNMP linkUp/linkDown trap:
--
-- none : disable linkUp/linkDown trap generation.
--
-- any : enable bintec like trap generation.
-- - entering the up state generates a up trap
-- - any other state change generates a down trap
--
-- up : enable rfc1157 like trap generation.
-- - entering the up state generates a up trap
-- - leaving the up state generates a down trap
--
-- down : enable rfc2233 like trap generation.
-- - leaving the down state generates a up trap
-- - entering the down state generates a down trap
--
-- Seven parameters are sent in each linkUp/linkDown trap pdu:
-- 1. ifEntry.ifIndex (mandatory for linkUp/Down traps)
-- 2. ifEntry.ifDescr
-- 3. ifEntry.ifType
-- 4. ifEntry.ifAdminStatus
-- 5. ifEntry.ifOperStatus
-- 6. system.Description
-- 7. system.Name"
-- DEFVAL { up }
-- ::= { admin 44 }
biboAdmExtendedBanner OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is an additional banner message which is displayed
after the standard welcome message at boot time.
This message is typically used to display info regarding
a special configuration of the router."
DEFVAL { "" }
::= { admin 45 }
biboAdmBootpRelayServ2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the second destination IP address
to which BOOTP/DHCP request are forwarded by the
BIANCA/BRICK BOOTP relay agent.
If this entry is empty no BOOTP forwarding is done."
::= { admin 47 }
biboAdmTimedBootPolicy OBJECT-TYPE
SYNTAX INTEGER {
normal(1), -- same behaviour as in normal operation
aggressive(2), -- send more frequent retries for 10 minutes
endless(3) -- same as aggressive, do not stop at all
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the frequency with which the timed
requests the time (using the specified time protocol)
after system startup until the first reply is received.
Possible values:
normal(1): -- 5 retries after 1, 2, 4, 8, 16 minutes
aggressive(2): -- retry 10 minutes with 1, 2, 4, 8, 10, 10, ...
seconds of timeout
endless(3): -- same as aggressive except there is no time
limit."
DEFVAL { endless }
::= { admin 48 }
biboAdmAcctlogFormat OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the format of accounting messages sent by
the syslog protocol. The format can consist of any order
of random strings, backslash escaped sequences like '\t','\n', etc.
or the following format tags:
Tag Meaning
%d Date the session opened; in DD.MM.YY format.
%t Time the session opened: in HH:MM:SS format
%a session age in seconds
%c protocol type
%i source IP address
%r source port
%f source interface index
%I destination IP address
%R destination port
%F destination interface index
%p outgoing packets
%o outgoing octets
%P incoming packets
%O incoming octets
%s message sequence counter
%% '%'
The format for accounting messages is per default:
'INET: %d %t %a %c %i:%r/%f -> %I:%R/%F %p %o %P %O [%s]'
"
DEFVAL { "INET: %d %t %a %c %i:%r/%f -> %I:%R/%F %p %o %P %O [%s]" }
::= { admin 49 }
biboAdmAcctlogMaxEntries OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum Number of accounting messages stored in memory."
DEFVAL { 20 }
::= { admin 50 }
biboAdmAcctlogTable OBJECT-TYPE
SYNTAX SEQUENCE OF BiboAdmAcctlogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The biboAdmAcctlogTable keeps track of accounting messages
received. The columns specify attributes for each message generated. As
this information only reports events on the system, all
fields are read-only.
Creating entries: Entries can only be created by the
system and are made each time a message for accounting is
generated.
Deleting entries: Entries are removed by the system
the messages are sent to the loghost."
::= { admin 51 }
biboAdmAcctlogEntry OBJECT-TYPE
SYNTAX BiboAdmAcctlogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { biboAdmAcctlogLevel }
::= { biboAdmAcctlogTable 1 }
BiboAdmAcctlogEntry ::=
SEQUENCE {
biboAdmAcctlogTimeStamp Date,
biboAdmAcctlogLevel INTEGER,
biboAdmAcctlogMessage DisplayString,
biboAdmAcctlogSubject INTEGER
}
biboAdmAcctlogTimeStamp OBJECT-TYPE
SYNTAX Date
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time message was generated."
::= { biboAdmAcctlogEntry 1 }
biboAdmAcctlogLevel OBJECT-TYPE
SYNTAX INTEGER {
emerg(1),
alert(2),
crit(3),
err(4),
warning(5),
notice(6),
info(7),
debug(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Level of acct message."
DEFVAL { info }
::= { biboAdmAcctlogEntry 2 }
biboAdmAcctlogMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The text of the acct message."
::= { biboAdmAcctlogEntry 4 }
biboAdmAcctlogSubject OBJECT-TYPE
SYNTAX INTEGER {
acct(1),
isdn(2),
inet(3),
x25(4),
ipx(5),
capi(6),
ppp(7),
bridge(8),
config(9),
snmp(10),
x21(11),
token(12),
ether(13),
radius(14),
tapi(15),
ospf(16),
fr(17),
modem(18),
rip(19),
atm(20),
pabx(21),
ipsec(22),
tty(23),
bgp(24),
tacacs(25),
brrp(26),
mps(27),
voip(28),
tr069(29),
wlan(30),
usb(31),
http(32),
inet6(33),
wlc(34),
ldap(35),
osp(36),
wtp(37),
tremp(38),
presence(39)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Subject of the acct message."
DEFVAL { acct }
::= { biboAdmAcctlogEntry 5 }
biboAdmSyslogEntry OBJECT-TYPE
SYNTAX BiboAdmSyslogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { biboAdmSyslogTimeStamp, biboAdmSyslogLevel }
::= { biboAdmSyslogTable 1 }
BiboAdmSyslogEntry ::=
SEQUENCE {
biboAdmSyslogTimeStamp Date,
biboAdmSyslogLevel INTEGER,
biboAdmSyslogMessage DisplayString,
biboAdmSyslogSubject INTEGER
}
biboAdmSyslogTimeStamp OBJECT-TYPE
SYNTAX Date
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time message was generated."
::= { biboAdmSyslogEntry 1 }
biboAdmSyslogLevel OBJECT-TYPE
SYNTAX INTEGER {
emerg(1),
alert(2),
crit(3),
err(4),
warning(5),
notice(6),
info(7),
debug(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Level of syslog message."
DEFVAL { emerg }
::= { biboAdmSyslogEntry 2 }
biboAdmSyslogMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The text of the syslog message."
::= { biboAdmSyslogEntry 4 }
biboAdmSyslogSubject OBJECT-TYPE
SYNTAX INTEGER {
acct(1),
isdn(2),
inet(3),
x25(4),
ipx(5),
capi(6),
ppp(7),
bridge(8),
config(9),
snmp(10),
x21(11),
token(12),
ether(13),
radius(14),
tapi(15),
ospf(16),
fr(17),
modem(18),
rip(19),
atm(20),
pabx(21),
ipsec(22),
tty(23),
bgp(24),
tacacs(25),
brrp(26),
mps(27),
voip(28),
tr069(29),
wlan(30),
usb(31),
http(32),
inet6(33),
wlc(34),
ldap(35),
osp(36),
wtp(37),
tremp(38),
presence(39)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Subject of the syslog message."
DEFVAL { acct }
::= { biboAdmSyslogEntry 5 }
biboAdmTimeSource OBJECT-TYPE
SYNTAX INTEGER {
none(1), -- time has not been initialized yet
rtc(2), -- time has been initialized by real time clock
manual(3), -- time has been set manually
isdn(4), -- time has been set by ISDN
server(5), -- time has been received from a time server
gps(6) -- time has been received from GPS
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source of the current system time."
DEFVAL { none }
::= { admin 52 }
biboAdmIsdnTimeUpdate OBJECT-TYPE
SYNTAX INTEGER {
enabled(1), -- time retrieval over ISDN is enabled
disabled(2), -- time retrieval over ISDN is disabled
convert(3) -- convert setting in TimeProtocol
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies whether a time value which has been
retrieved via ISDN should be used to set the system time.
Note that the time retrieved via ISDN is ignored if the system
time has been set by a time server previously."
DEFVAL { convert }
::= { admin 53 }
biboAdmSyslogTcpRetries OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum number of attempts to connect a syslog server over TCP."
DEFVAL { 3 }
::= { admin 55 }
biboAdmSWVersionOS OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the OS software release version as it was always found
in biboAdmSWVersion."
::= { admin 56 }
biboAdmSWVersionOEM OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the OEM software release version.
Either there's a separate OEM version defined or this is
identical to biboAdmSWVersionOS."
::= { admin 57 }
biboAdmStartMode OBJECT-TYPE
SYNTAX INTEGER { normal(1), service(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If service procedure is activated, mode is set to service,
otherwise mode is set to normal."
::= { admin 58 }
extadmin OBJECT IDENTIFIER
::= { admin-2 1 }
biboExtAdmMonAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the host machine running the Activity
Monitor program. This program displays the information
about the current state of all interfaces.
Periodically UDP packets are send to this IP address,
to refresh the data automatically on the target host.
The value 255.255.255.255 represents the broadcast address
of the first LAN interface (e.g. 10.255.255.255), so
more than one Activity Monitor on different hosts can
receive the data."
DEFVAL { 'ffffffff'H }
::= { extadmin 1 }
biboExtAdmMonPort OBJECT-TYPE
SYNTAX INTEGER (0 .. 65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"UDP port for the Activity Monitor protocol."
DEFVAL { 2107 }
::= { extadmin 2 }
biboExtAdmMonType OBJECT-TYPE
SYNTAX INTEGER {
off(1), physical(2), physical-virt(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter configures the content of the Activity Monitor
packets, or disables it:
off : Activity Monitor disabled
physical : send only physical interfaces information
physical-virt: send physical and virtual interface
information."
DEFVAL { off }
::= { extadmin 3 }
biboExtAdmMonUpdate OBJECT-TYPE
SYNTAX INTEGER (0 .. 60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the time interval for the Activity Monitor
for sending packets (in seconds) to the specified IP address.
The value of 0 disables sending Activity Monitor packets."
DEFVAL { 5 }
::= { extadmin 4 }
biboExtAdmProcRouted OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"enabled: The routed process is running.
RIP and/or OSPF are available (subject to licenses).
This is the default behavior of the system.
Hints:
RIP may be enabled/disabled by 'biboAdmRipUdpPort'
OSPF may be enabled/disabled by 'ospfAdminStat'
RIP may be if-specific ena/disabled by 'ipExtIfRip*'
OSPF may be if-specific ena/disabled by 'ipExtIfOspf'
... but a running routed process consumes CPU-Time
to keep in sync with interface/routing tables - even
if RIP and OSPF are disabled (global or if-specific).
disabled: The routed process is stopped.
RIP and/or OSPF are unavailable.
Hints:
A stopped routed process consumes no CPU-Time.
Set ipExtAdmProcRouted to 'disabled' is recommended
if both protocols (RIP and OSPF) not used in the
specific router environment.
"
DEFVAL { enabled }
::= { extadmin 5 }
biboExtAdmProcWatchDog OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"enabled: The watchd process is running.
up/down transitions on interfaces delivered by
various protocols like ping/ifOperStatus/VRRP
are processed by parsing a task table and slave
interfaces are switched up/down according to the
task definition.
disabled: The watchd process is stopped."
DEFVAL { disabled }
::= { extadmin 7 }
biboExtAdmProcSSHd OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"enabled: The sshd process is running.
disabled: The sshd process is stopped."
DEFVAL { enabled }
::= { extadmin 8 }
biboExtAdmScheduleInterval OBJECT-TYPE
SYNTAX INTEGER (0 .. 65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the time interval in seconds for the Schedule
daemon watching any events (recommended value: 300).
The value 0 disables the scheduler.
Referring table: scheduleTable"
DEFVAL { 0 }
::= { extadmin 9 }
biboExtAdmUpdatePath OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default URL for automatic SW updates, e.g. http://server/path/
This setting is IGNORED if chkUpdSrvAdminOperURL is not empty.
Otherwise, related chkUpdSrv entry is allocated for it.
If URL does NOT end with '/' then it is considered being
complete and copied to related chkUpdSrvDownloadLink.
Otherwise, following parts are appended automatically.
'<sysname>[-<mode>]/<sysname>[-<mode>]-s_current'"
DEFVAL { "http://system-update.eu/" }
::= { extadmin 10 }
biboExtAdmBackRtVerify OBJECT-TYPE
SYNTAX INTEGER { always(1), interface-dependent(2), never(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object activates an additional check for incoming
packets. If set to always (1), incoming packets are only
accepted if return packets sent back to their source IP
address would be sent over the same interface. This prevents
packets being passed from untrusted interfaces to this
interface. If set to interface-dependent (2), this check
will be performed only if enabled for the associated ingress
interface (see ipExtIfBackRtVerify). If set to never (2),
this check will be never performed, regardless wether enabled
or not for the associated interface."
DEFVAL { interface-dependent }
::= { extadmin 11 }
biboExtAdmRerouteViaDefault OBJECT-TYPE
SYNTAX INTEGER { disabled(1), enabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the behaviour of the routing algorithm
when a network route exists for routing a packet, but is
temporarily unusable because the status of the associated
interface prevents transmission. In such a case, the routing
algorithm tries to select an alternate route to allow the
packet to reach its destination. If set to disabled (1),
default routes are discarded during the search for a suitable
alternate route. If set to enabled (2), a default route may
be selected for rerouting provided it is the most appropriate
route available."
DEFVAL { disabled }
::= { extadmin 12 }
biboExtAdmGUILanguage OBJECT-TYPE
SYNTAX DisplayString (SIZE(3))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the language used within the graphical
user interface (currently new web based interface only).
Valid abbreviations (in principle) are defined in ISO 639-2."
DEFVAL { "eng" }
::= { extadmin 13 }
biboExtAdmIpLogging OBJECT-TYPE
SYNTAX BITS { nat(0), tcppr(1), dns(2), ips(3), acl(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This bitfield enables logging of dedicated subsystems
within the INET subject:
nat : NAT
tcppr : TCP processing (MSS clamping, ...)
dns : DNS
ips : IP session management
acl : Local Services Access Control
."
DEFVAL { { nat, tcppr, dns, ips, acl } }
::= { extadmin 14 }
biboExtAdmRadiusNasId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An administratively-assigned NAS identifier for this managed
node. If configured this variable is used for each RADIUS
request in order to set the associated NAS-IDENTIFIER RADIUS
attribute value."
::= { extadmin 15 }
biboExtAdmConfigSaveDate OBJECT-TYPE
SYNTAX Date
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp when configuration gets/got saved (system local
time)."
DEFVAL { 0 }
::= { extadmin 17 }
biboExtAdmSnmpShellPrompt OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines prompt of application SNMP shell.
A set of escape sequences is defined with escape character
being a backslash '\':
- 'e': gets replaced by escape character (0x1b)
- 'h': gets replaced by system name (i.e. host)
- 'T': can be used for MIB context replacements ...
%n -> current MIB table name
%# -> current MIB table number
%g -> current MIB group number
A longer string can be put within parentheses '(' ')'
causing the whole string to be left out if no context
is available instead of only the MIB variables.
Examples, assuming context MIB table 'system':
String Yields
------------------------+------------------------
\T%n | 'system'
\T( MIB{%n/#%#/g:%g\)}) | ' MIB{system/#1/g:1}'
- 'l': gets replaced by log name (i.e. user, normally admin)
- 'd': can be used for date/time replacements with '%'
escaped replacements ...
%C -> century
%d -> day of month (01..31)
%D -> date in format 'MM/DD/YY'
%F -> date in format YYYY-MM-DD
%H -> hour (00..23)
%I -> hour (01..12)
%j -> day of year (1..366)
%k -> hour ( 0..23)
%l -> hour ( 1..12)
%m -> month (01..12)
%M -> minute (00..59)
%p -> AM/PM
%P -> am/pm
%R -> 24 hour time in format HH:MM
%s -> seconds sincs 1970-01-01 00:00:00 UTC
%S -> seconds (00..59)
%T -> 24 hour time in format HH:MM:SS
%u -> day of week (1..7)
%w -> day of week (0..6)
%y -> year (last two digits, 00..99)
%Y -> year
A longer string can be put within parentheses '(' ')'
to save repetitions of leading '\d' for every
replacement.
- 'u': gets replaced by system's uptime in format
[D ]HH:MM:SS
Default value is '\h:\t(%n)> '."
DEFVAL { "\h:\T(%n)> " }
::= { extadmin 18 }
biboExtAdmMinArpLifeTime OBJECT-TYPE
SYNTAX INTEGER (0 .. 86400)
UNITS "s"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the minimum lifetime (in seconds)
of ipNetToMediaTable entries."
DEFVAL { 0 }
::= { extadmin 19 }
biboExtAdmInitialGUIView OBJECT-TYPE
SYNTAX INTEGER { full-access(1), user(2), initial-operation(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the initial GUI behavior for admin login
for boxes with supports of 'GUI Views' and 'Initial Operation View' in GUI.
full-access: show the complete admin navigation.
user: show the user view
initial-operation: show the initial operation view.
If initial operation is not supported fall back to user view,
if user view is not supported fall back to full access."
DEFVAL { initial-operation }
::= { extadmin 21 }
-- Time Server Table
timeServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF TimeServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the list of time servers."
::= { admin 54 }
timeServerEntry OBJECT-TYPE
SYNTAX TimeServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object contains a time server entry."
INDEX {
timeSrvPriority
}
::= { timeServerTable 1 }
TimeServerEntry ::=
SEQUENCE {
timeSrvPriority INTEGER,
timeSrvProtocol INTEGER,
timeSrvAddress DisplayString
}
timeSrvPriority OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The priority of the time server.
The time servers are queried in the order of ascending priority
value, i.e. 0 first, 1 second ... ."
::= { timeServerEntry 1 }
timeSrvProtocol OBJECT-TYPE
SYNTAX INTEGER {
delete(1), -- delete this entry
time-udp (2), -- time protocol over udp
time-tcp (3), -- time protocol over tcp
sntp (4), -- sntp protocol
disabled (5) -- disabled
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The protocol used for the time server."
DEFVAL { sntp }
::= { timeServerEntry 2 }
timeSrvAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Address or DNS name of the time server. If a DNS name
is specified here, it is resolved on demand."
::= { timeServerEntry 3 }
-- End Time Server Table
biboAdmNTPServer OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2),
clientdepend(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field controls the NTP server. If it is set to
disabled(1) client requests will be ignored. Setting it
to enabled(2) on every client request a server answer
is transmitted. In clientdepend(3) mode only a answer to
a client request is sent if an external reference exists."
DEFVAL { disabled }
::= { admin 59 }
biboAdmTimeZone OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the currently set timezone. The corresponding
timezone must exist in timeZoneTable."
::= { admin 60 }
timeZoneTable OBJECT-TYPE
SYNTAX SEQUENCE OF TimeZoneEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the list of availabe timezones."
::= { admin 61 }
timeZoneEntry OBJECT-TYPE
SYNTAX TimeZoneEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object contains a time zone entry."
INDEX {
timeZoneIndex
}
::= { timeZoneTable 1 }
TimeZoneEntry ::=
SEQUENCE {
timeZoneIndex INTEGER,
timeZoneName DisplayString,
timeZoneAlias DisplayString,
timeZoneOffset INTEGER
}
timeZoneIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index in Timezone Table."
::= { timeZoneEntry 1 }
timeZoneName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Name of a Timezone."
::= { timeZoneEntry 2 }
timeZoneAlias OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The abbreviation of a timezone."
::= { timeZoneEntry 3 }
timeZoneOffset OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timezone offset from UTC in seconds. Note that this contains
no information about daylight saving for this timezone"
::= { timeZoneEntry 4 }
ntpServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF NtpServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of DHCP-client-learned NTP-servers, relevant only if
related administrative table timeServer is empty."
::= { admin 64 }
ntpServerEntry OBJECT-TYPE
SYNTAX NtpServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object contains a time server entry."
INDEX { ntpServerPriority }
::= { ntpServerTable 1 }
NtpServerEntry ::=
SEQUENCE {
ntpServerPriority INTEGER,
ntpServerAddress DisplayString
}
ntpServerPriority OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Priority of NTP-server. Lower value means 'preferred'."
::= { ntpServerEntry 1 }
ntpServerAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP-address or FQDN of NTP-server."
::= { ntpServerEntry 2 }
sysStat OBJECT IDENTIFIER
::= { sys 500 }
sysStatBootConfig OBJECT-TYPE
SYNTAX INTEGER {
none(1), -- no config at all
bootfac(2), -- factory boot config
default(3), -- default config
boot(4) -- boot config from flash
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"After system boot this variable shows which configuration
was loaded:
none: no configuration whatsoever
bootfac: factory boot configuration
default: default configuration as provided by image
boot: configuration found in flash."
DEFVAL { none }
::= { sysStat 1 }
sysStatFunctionState OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable contains the current function state, which is
toggeled by pressing the function button on the device."
::= { sysStat 2 }
-- next variable is intentionally saved to indicate operation mode
-- a configuration was saved with
sysStatOperationMode OBJECT-TYPE
SYNTAX INTEGER { plain(0), mgw(1), pbx(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable defines the operation mode of the device
concerning telephony functionality.
If any voice functionality is integrated it can be either
mgw(1) for Media GateWay functionality of pbx(2) for a
full-fledged telephone system.
For systems w/o voice functionality the variable has value
plain(0)."
::= { sysStat 3 }
sysStatConfigConvert OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable handles the Configuration Conversion from
pbx to mgw (later may be mgw to pbx)
For systems w/o voice functionality the variable has value
plain(0)."
DEFVAL{ idle }
::= { sysStat 4 }
sysStatConfigConvertState OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
progress(2),
done(3),
failed(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable handles the Configuration Conversion state
idle - No conversion in progress
progress - conversion in progress
done - conversion done
failed - conversion not possible
The value is set to progress during tne coversion progress.
On errer e.g configuration parameters already exists the
State is set to failed otherwise the State is set to idle
on success."
DEFVAL{ idle }
::= { sysStat 5 }
-- Trace buffers
traceBuffers OBJECT IDENTIFIER ::= { admin 65 }
-- administrative section
trcBufAdmin OBJECT IDENTIFIER ::= { traceBuffers 1 }
trcBufTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrcBufEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the list trace buffers."
::= { trcBufAdmin 1 }
trcBufEntry OBJECT-TYPE
SYNTAX TrcBufEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object contains a trace buffer entry."
INDEX {
trcBufIndex
}
::= { trcBufTable 1 }
TrcBufEntry ::=
SEQUENCE {
trcBufIndex INTEGER,
trcBufDevice DisplayString,
trcBufMode INTEGER,
trcBufDataMode INTEGER,
trcBufSize INTEGER,
trcBufDataSize INTEGER,
trcBufDate INTEGER,
trcBufDescr DisplayString,
trcBufID Unsigned32,
trcBufOperation INTEGER
}
trcBufIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique Index of the trace buffer"
::= { trcBufEntry 1 }
trcBufDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The device representing this trace buffer"
::= { trcBufEntry 2 }
trcBufMode OBJECT-TYPE
SYNTAX INTEGER { single-shot(1), continuous(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates operation mode of trace buffer:
single-shot: just fill buffer up to maximum size
continuous: ring buffer mode
In single-shot mode every write attempt that would exceed
buffer limits, causes the buffer to get closed for writing
and the write attempt to fail (as any further attempts will).
In continuous mode the buffer is filled up to the maximum size,
and overwrite older data as new data gets written.
Variable is meaningless as long as variable trcBufOperation
is set to unused."
::= { trcBufEntry 3 }
trcBufDataMode OBJECT-TYPE
SYNTAX INTEGER {
bytestream(1),
message(2),
message-per-session(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates how trace buffer treats data written to it:
In bytestream mode no structure is imposed on written data,
buffer will get completely filled up if enough data is written.
Data overwrite is done byte-by-byte.
Mode message keeps the data structure in messages as passed
down to the trace buffer and allows for reading them back in
same portions as written.
Mode message-per-session treats any data written to trace
buffer between opening and closing it as one message.
Variable is meaningless as long as variable trcBufOperation
is set to unused.
NOTE: modes message and message-per-session only reflect the
last state; it depends on the application(s) writing to the
trace buffer in which mode it is used, so this variable can
toggle between these two states over time."
::= { trcBufEntry 4 }
trcBufSize OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum size of the trace buffer"
::= { trcBufEntry 5 }
trcBufDataSize OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current data size of the trace buffer"
::= { trcBufEntry 6 }
trcBufDate OBJECT-TYPE
SYNTAX Date
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time and date of the buffer creation"
::= { trcBufEntry 7 }
trcBufDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optional descriptive information of the buffer's purpose."
DEFVAL { "" }
::= { trcBufEntry 8 }
trcBufID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optional identificator for the buffer."
DEFVAL { "" }
::= { trcBufEntry 9 }
trcBufOperation OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
idle(2),
read(3),
write(4),
read-write(5),
closed(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the trace buffer:
unused: Device is free to be used
idle : Device is parameterized but not open
read : Device is open for reading
write: Device is open for writing
read-write: Device is open for reading and writing
full: No more writing to buffer possible
Value read-write would normally refer to two processes.
Value full indicates that no more data can be written to
buffer; it will remain unchanged until it gets deleted."
DEFVAL { unused }
::= { trcBufEntry 10 }
trcBufOper OBJECT IDENTIFIER ::= { traceBuffers 2 }
trcBufStatNBufs OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of trace buffers supported by running firmware."
::= { trcBufOper 1 }
trcBufStat OBJECT IDENTIFIER ::= { traceBuffers 3 }
trcBufStatNUnused OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of trace buffers currently available to store data."
::= { trcBufStat 1 }
trcBufStatNOpen OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of trace buffers currently available for appending
data."
::= { trcBufStat 2 }
trcBufStatNFull OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of trace buffers currently available for reading data
only (i.e. in state 'full')."
::= { trcBufStat 3 }
-- End Trace Buffers
-- Begin automatic update check sechedule
chkUpdSrv OBJECT IDENTIFIER ::= { extadmin 22 }
chkUpdSrvAdmin OBJECT IDENTIFIER
::= { chkUpdSrv 1 }
chkUpdSrvAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
ondemand(2),
periodic(3),
checknow(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tells when to fetch/process the XML-file-contents pointed at
by chkUpdSrvAdminOperURL (if not empty string).
disabled: Clear chkUpdSrvAdminOperURL and supress further
fetch-attempts.
ondemand: Fetch at system-start and at every change of
chkUpdSrvAdminOperURL (unless empty string).
periodic: In addition to 'ondemand', fetch also periodically
with specified chkUpdSrvAdminInterval.
checknow: Fetch now and switch-back AdminStatus to previous
value (i.e. to disabled, ondemand, periodic).
"
DEFVAL { periodic }
::= { chkUpdSrvAdmin 1 }
chkUpdSrvAdminInterval OBJECT-TYPE
SYNTAX INTEGER (1..8191)
UNITS "h"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Period in hours for checking for available updates.
Default value is once a week (7 * 24 = 168 hours).
Ignored if chkUpdSrvAdminStatus is NOT periodic.
"
DEFVAL { 168 }
::= { chkUpdSrvAdmin 2 }
chkUpdSrvAdminURL OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets location of the XML description file, UNLESS value is set
already at compile-time (see chkUpdSrvAdminOperURL).
"
::= { chkUpdSrvAdmin 3 }
chkUpdSrvAdminOperURL OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows location of the XML description file, coming from either
chkUpdSrvAdminURL or fixed compile-time-URL, or forced to empty
string if chkUpdSrvAdminStatus is disabled.
If resulting string is empty then chkUpdSrvTable is filled for
biboExtAdmUpdatePath instead, unless also empty.
"
::= { chkUpdSrvAdmin 4 }
chkUpdSrvAdminDefaultDigestType OBJECT-TYPE
SYNTAX INTEGER {
crc32(1),
sha256(2),
signature(3),
none(16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default digest-checking-method (if not specified in XML-file)
"
DEFVAL {sha256 }
::= { chkUpdSrvAdmin 5 }
chkUpdSrvAdminOperStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
idle(2),
checking(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current activity and state.
"
DEFVAL { idle }
::= { chkUpdSrvAdmin 6 }
chkUpdSrvAdminLastSuccessfulCheckTime OBJECT-TYPE
SYNTAX Date
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If not 0, tells when chkUpdSrvTable was last updated
successfully for contents coming from either
chkUpdSrvAdminOperURL or biboExtAdmUpdatePath.
Is reset to 0 whenever chkUpdSrvAdminOperURL changes.
"
::= { chkUpdSrvAdmin 7 }
chkUpdSrvAdminLastFailedCheckTime OBJECT-TYPE
SYNTAX Date
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If not 0, tells time of last unsuccessful update-attempt.
If bigger than chkUpdSrvAdminLastSuccessfulCheckTime then
retries are scheduled (see chkUpdSrvAdminLastFailedTries).
Is reset to 0 whenever chkUpdSrvAdminOperURL changes.
"
::= { chkUpdSrvAdmin 8 }
chkUpdSrvAdminLastFailedCheckInfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display-status of last unsuccessful update-attempt.
(Not updated for successful checks.)
Is flushed to empty whenever chkUpdSrvAdminOperURL changes.
"
DEFVAL { "" }
::= { chkUpdSrvAdmin 9 }
chkUpdSrvAdminActiveProductClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Currently active product-class.
"
::= { chkUpdSrvAdmin 10 }
chkUpdSrvAdminAlternativeProductClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alternative product-class (empty if unknown).
"
::= { chkUpdSrvAdmin 11 }
chkUpdSrvAdminLastFailedTries OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If not 0, tells that retries are scheduled for latest failed
update-check, and how many tries have been done yet (see also
chkUpdSrvAdminLastFailedCheckTime for related timestamp).
Is reset to 0 whenever update-check succeeds or restarts (e.g.
due to changed chkUpdSrvAdminOperURL).
"
::= { chkUpdSrvAdmin 12 }
chkUpdSrvTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChkUpdSrvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of available update-files. When update-command is called
with dummy-URL 'http:', it looks for a matching default-entry
in this table to get a proper chkUpdSrvDownloadLink.
"
::= { chkUpdSrv 2 }
chkUpdSrvEntry OBJECT-TYPE
SYNTAX ChkUpdSrvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Detailed info per listed update-file.
"
INDEX {
chkUpdSrvIndex
}
::= { chkUpdSrvTable 1 }
ChkUpdSrvEntry ::=
SEQUENCE {
chkUpdSrvIndex INTEGER,
chkUpdSrvProductClass DisplayString,
chkUpdSrvFileType INTEGER,
chkUpdSrvFileDescr DisplayString,
chkUpdSrvFileVersion DisplayString,
chkUpdSrvFileDigestType INTEGER,
chkUpdSrvFileDigestValue DisplayString,
chkUpdSrvDownloadLink DisplayString,
chkUpdSrvRelNoteLink DisplayString,
chkUpdSrvFileUpdatable INTEGER
}
chkUpdSrvIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identification of the entry.
"
::= { chkUpdSrvEntry 1 }
chkUpdSrvProductClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Product-class for file.
"
::= { chkUpdSrvEntry 2 }
chkUpdSrvFileType OBJECT-TYPE
SYNTAX INTEGER {
blup(1),
boss(2),
logic(3),
bootmon(4),
adsl(5),
vdsl(6),
gphy(7),
systelarchive(20),
voicemailarchive(21),
guixlation(30),
thirdparty(50)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of file.
"
DEFVAL { blup }
::= { chkUpdSrvEntry 3 }
chkUpdSrvFileDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Additional file-description,
used for language and third party files.
"
::= { chkUpdSrvEntry 4 }
chkUpdSrvFileVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Version of file (empty if unknown).
"
::= { chkUpdSrvEntry 5 }
chkUpdSrvFileDigestType OBJECT-TYPE
SYNTAX INTEGER {
crc32(1),
sha256(2),
signature(3),
none(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Method to be used for digest-checking
"
DEFVAL {sha256 }
::= { chkUpdSrvEntry 6 }
chkUpdSrvFileDigestValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hash/signature for this file, depending on digest-type.
"
::= { chkUpdSrvEntry 7 }
chkUpdSrvDownloadLink OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"URL for downloading this file.
"
::= { chkUpdSrvEntry 8 }
chkUpdSrvRelNoteLink OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"URL for downloading release-notes (if any) for this file.
"
DEFVAL { "" }
::= { chkUpdSrvEntry 9 }
chkUpdSrvFileUpdatable OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tells if system can be updated with this file.
false: Update will not work or have no effect
true: Update will have effect
unknown: No info available (e.g. unknown file-version)
"
DEFVAL { unknown }
::= { chkUpdSrvEntry 10 }
END -- of BIANCA-BRICK definitions