mibs/MIBS/brocade/FOUNDRY-SN-AGENT-MIB
2023-12-05 12:25:34 +01:00

6456 lines
174 KiB
Plaintext

FOUNDRY-SN-AGENT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,TimeTicks, IpAddress, Counter32, Gauge32,Unsigned32,Integer32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus, TruthValue, TimeStamp
FROM SNMPv2-TC
InterfaceIndex
FROM IF-MIB
InetAddressType, InetAddress
FROM INET-ADDRESS-MIB -- [RFC 4001]
CounterBasedGauge64
FROM HCNUM-TC
snChassis, snAgentSys, snStack
FROM FOUNDRY-SN-ROOT-MIB;
snAgent MODULE-IDENTITY
LAST-UPDATED "201112220000Z" -- 22 December 2011
ORGANIZATION "Brocade Communications Systems, Inc."
CONTACT-INFO
"Technical Support Center
130 Holger Way,
San Jose, CA 95134
Email: ipsupport@brocade.com
Phone: 1-800-752-8061
URL: www.brocade.com"
DESCRIPTION
"Copyright 1996-2010 Brocade Communications Systems, Inc.
All rights reserved.
This Brocade Communications Systems SNMP Management Information Base Specification
embodies Brocade Communications Systems' confidential and proprietary
intellectual property. Brocade Communications Systems retains all
title and ownership in the Specification, including any revisions.
This Specification is supplied AS IS, and Brocade Communications Systems makes
no warranty, either express or implied, as to the use,
operation, condition, or performance of the specification, and any unintended
consequence it may on the user environment."
REVISION "201112220000Z" -- 22 December 2011
DESCRIPTION
"Major Changes in NI 5.3: Added MIBs for Simplified Upgrade,
Fixes for status for 100G module in blocked slot,
SNMP support for MR2 module
Description Updates."
REVISION "201006020000Z" -- 04 June 2010
DESCRIPTION
"Changed the ORGANIZATION, CONTACT-INFO and DESCRIPTION fields."
REVISION "200909300000Z" -- September 30, 2009
DESCRIPTION
"convert from SMIv1 to SMIv2"
::= { iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 1991 4}
-- textual conventions
MacAddress ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"
This data type is used to model media addresses. For many
types of media, this will be in a binary representation.
For example, an ethernet address would be represented as
a string of 6 octets.
"
SYNTAX OCTET STRING (SIZE(6))
DisplayString ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used to model textual information taken
from the NVT ASCII character set. By convention, objects
with this syntax are declared as having
SIZE (0..255)"
SYNTAX OCTET STRING
BrcdImageType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Image types supported by XMR/MLX and CES/CER"
SYNTAX INTEGER {
unknown(1),
managementModuleBoot(2),
managementModuleMonitor(3),
managementModuleApplication(4),
interfaceModuleBoot(5),
interfaceModuleMonitor(6),
interfaceModuleApplication(7),
mgmtAndIntfModuleCombinedApp(8),
fpgaMBridge(9),
fpgaMBridge32(10),
fpgaSBridge(11),
fpgaHBridge(12),
fpgaBundled(13),
fpgaPbifOc(14),
fpgaStatsOc(15),
fpgaXppOc(16),
fpgaPbifMrj(17),
fpgaStatsMrj(18),
fpgaXppMrj(19),
fpgaPbifSp2(20),
fpgaXgmacSp2(21),
fpgaXppSp2(22),
fpgaPbif8x10(23),
fpgaXpp8x10(24),
fpgaXpp2x100(25),
fpgaPbifMetro(26)
}
-- Groups
snChasGen OBJECT IDENTIFIER ::= { snChassis 1 }
snChasPwr OBJECT IDENTIFIER ::= { snChassis 2 }
snChasFan OBJECT IDENTIFIER ::= { snChassis 3 }
snChasUnit OBJECT IDENTIFIER ::= { snChassis 4 }
-- SECTION 2: MIB Objects
-- General Chassis Information
snChasType OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The chassis type represents the type
of Foundry product being managed. "
::= { snChasGen 1 }
snChasSerNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of the chassis. If the
serial number is unknown or unavailable then
the value should be a zero length string."
::= { snChasGen 2 }
-- Power Supply Status
snChasPwrSupplyStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object is being deprecated, please use snChasPwrSupplyTable instead.
A bit array that contains the value of the
Chassis Power Supplies. This is a packed bit string;
the 2 power supplies status are encoded into 4 bits
(a nibble).
There are multiple power supplies per chassis in this release.
The following shows the meaning of each bit:
(bit 0 is the least significant bit).
bit position meaning
------------ -------
20-31 reserved
19 Power Supply 8 DC (0=bad, 1=good).
18 Power Supply 7 DC (0=bad, 1=good).
17 Power Supply 8 present status (0=present, 1=not-present).
16 Power Supply 7 present status (0=present, 1=not-present).
15 Power Supply 6 DC (0=bad, 1=good).
14 Power Supply 5 DC (0=bad, 1=good).
13 Power Supply 6 present status (0=present, 1=not-present).
12 Power Supply 5 present status (0=present, 1=not-present).
11 Power Supply 4 DC (0=bad, 1=good).
10 Power Supply 3 DC (0=bad, 1=good).
9 Power Supply 4 present status (0=present, 1=not-present).
8 Power Supply 3 present status (0=present, 1=not-present).
4-7 reserved
3 Power Supply 2 DC (0=bad, 1=good).
2 Power Supply 1 DC (0=bad, 1=good).
1 Power Supply 2 present status (0=present, 1=not-present).
0 Power Supply 1 present status (0=present, 1=not-present)."
::= { snChasGen 3 }
-- Fan Status
snChasFanStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object is being deprecated, please use snChasFanTable instead.
A bit array that contains the value of the
fan status. This is a packed bit string. The
status of each fan is encoded into one bit.
bit value meaning
--------- -------
0 fan failure.
1 fan good.
There are two fans per VLAN Switch chassis in this release.
The following shows the meaning of each bit:
(bit 0 is the least significant bit).
bit position meaning
------------ -------
6-31 reserved
5 fan6 status
4 fan5 status
3 fan4 status
2 fan3 status
1 fan2 status
0 fan1 status"
::= { snChasGen 4 }
snChasMainBrdDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main board description string. (It is obsoleted for Chassis Product)"
::= { snChasGen 5 }
snChasMainPortTotal OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of ports for the main board. (It is obsoleted for Chassis Product)"
::= { snChasGen 6 }
snChasExpBrdDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The expansion board description string. Expansion
board are those boards attaching on the main board.
(It is obsoleted for Chassis Product)"
::= { snChasGen 7 }
snChasExpPortTotal OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of ports for the expansion board.
(It is obsoleted for Chassis Product)"
::= { snChasGen 8 }
snChasStatusLeds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel status LEDs. This is a bit-map;
each LED is encoded into 1 bit for each switch
port. The maximum number of ports in one chassis
is 24 that means 24 Ports Status LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
-------- ---------
0 off (Link off)
1 on (Link on)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
--------"
::= { snChasGen 9 }
snChasTrafficLeds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel traffic LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch
port. The maximum number of ports in one chassis
is 24 that means 24 Ports Traffic LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
-------- ---------
0 off (no traffic)
1 on (traffic)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
--------"
::= { snChasGen 10 }
snChasMediaLeds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch port.
The maximum number of ports in one chassis is 24
that means 24 Ports Media LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
--------- -------
0 half duplex
1 full duplex
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
---------"
::= { snChasGen 11 }
snChasEnablePwrSupplyTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate power supply failure traps."
DEFVAL { enabled }
::= { snChasGen 12 }
snChasMainBrdId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main board identifier, which can uniquely identify a board
type. It is an encoded octet string with the following meaning:
octet 0 - octet string format version, which identifies the
format of this string.
If format version octet has the value 1, the octets after the
version octet have the following meaning:
octet 1 - product type, FIWG=0x57, FIBB=0x42, FIMLS=0x4D
NI=0x4E, TI=0x54, TIRT=0x52
octet 2 - board type, POWERPC=1, ALPHA=2
The length of the octet string is 27.
If format version octet has the value 2, the octets after the
version octet have the following meaning:
octet 1 - product type:
BI_WG 0x57
BI_BB 0x42
BI_NI 0x4E
NI_M4 0x4D
BI_SLB 0x53
octet 2 - module type:
MASTER_FIBER_8G 0x0
MASTER_FIBER_4G 0x1
MASTER_COPPER_16 0x2
SLAVE_FIBER_4G 0x3
FI_MASTER_FIBER_2G 0x4
FI_MASTER_FIBER_4G 0x5
MASTER_COPPER_8G 0x6
FI_MASTER_FIBER_8G 0x7
SLAVE_FIBER_8G 0x8
MASTER_COPPER_12_2 0x9
SLAVE_COPPER_24 0xA
FI_SLAVE_COPPER_24 0xB
SLAVE_100FX_8 0xD
SLAVE_100FX_16 0xC
SLAVE_COPPER_8G 0xE
SLAVE_COPPER_16_2 0xF
STACK_FIBER_8G 0x10
STACK_COPPER_8G 0x11
MASTER_FIBER_2G 0x12
SLAVE_100FX_24 0x13
MASTER_FIBER_0G 0x14
POS_622M 0x15
POS_155M 0x16
SLAVE_FIBER_2G 0x17
SLAVE_COPPER_2G 0x18
FI_SLAVE_FIBER_2G 0x19
FI_SLAVE_FIBER_4G 0x1A
FI_SLAVE_FIBER_8G 0x1B
FI_SLAVE_COPPER_8G 0x1C
FI_MASTER_COPPER_8G 0x1D
POS_155M2P 0x1E
FI_MASTER_COPPER_4G 0x1F
FI_MASTER_COPPER_2G 0x20
MASTER_COPPER_4G 0x21
MASTER_COPPER_2G 0x22
MASTER_M4_8G 0x23
MASTER_M4_4G 0x24
MASTER_M4_2G 0x25
MASTER_M4_0G 0x26
MASTER_M5_0G 0x27
POS_2488M 0x28
SLAVE_M5_0G 0x29
POS_N2488M 0x2A
STACK_IPC_48_2 0x2B
SLAVE_NPA_FIBER_4G 0x2C
ATM_2PORT 0x2D
ATM_4PORT 0x2E
SLAVE_FIBER_10G 0x2F
STACK_FES_48_2 0x30
STACK_FES_24_2 0x31
STACK_FES_96_4 0x32
STACK_FES_12G 0x33
STACK_FESX_24G 0x34
STACK_FESX_24_2_G 0x35
STACK_FESX_24_1_G 0x36
STACK_FESX_48G 0x37
STACK_FESX_48_2_G 0x38
STACK_FESX_48_1_G 0x39
SUPERX_FI_MGMT 0x40
SUPERX_FI_2P10G 0x41
SUPERX_FI_24GC 0x42
SUPERX_FI_24GF 0x43
SUPERX_FI_2P10G_WAN 0x44
SUPERX_FI_MGMT_II 0x4a
SLAVE_JC_48E 0xC3
SLAVE_JC_48T 0xC4
MASTER_JC_M4_8G 0xC5
SLAVE_JC_8G 0xC6
SLAVE_JC_B16GF 0xC8
MASTER_JC_B2404 0xC9
SLAVE_JC_B16GC 0xCA
The length of the octet string is 28.
Both format version 1 and 2:
octet 3 - processor type, PVR_M603=3, PVR_M604=4, PVR_M603E=6,
PVR_M603EV=7, PVR_M750=8, PVR_M604E=9, PVR_M8245=81
octet 4 to
octet 5 - processor speed in MHz
octet 6 - MAC type:
MAC_NONE=0
MAC_SEEQ_10_100=1,
MAC_DEC_10_100=2,
MAC_3COM_10_100=3,
MAC_X10GMAC_10000=4,
MAC_SEEQ_1000=5,
MAC_GMAC_1000=6,
MAC_VLSI_1000=7
octet 7 - PHY type, PHY_NONE=0, PHY_QSI=1, PHY_BROADCOM=2,
PHY_ICS=3, PHY_NATIONAL=4, PHY_LEVEL1=6,
PHY_BROADCOM_10_100=7, PHY_LEVEL24=8,
PHY_BROADCOM_10000=9 (for 10G),
PHY_3COM_10_100=9 (for others)
octet 8 - port type, COPPER=0, FIBER=1
octet 9 - fiber port type, NONFIBER=0, SX_FIBER=1,
LX_FIBER=2, LHX_FIBER=3, LX_SX_FIBER=4,
LHB_FIBER=5
octet 10 to
octet 13 - DRAM size in KBytes
octet 14 to
octet 17 - boot flash size in KBytes
octet 18 to
octet 21 - code flash size in KBytes
octet 22 to
octet 27 - serial number.
Format version 1 only:
octet 28 - chassis backplane type.
chassis4000 = 0x00
chassis8000 = 0x02
chassis15000 = 0x01
chassisFISX = 0x04
Turbo8 = 0x07 (stack2)
FastIron2 = 0x06 (stack1)"
::= { snChasGen 13 }
snChasExpBrdId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The expansion board identifier. Expansion board are those
boards attaching on the main board. It is an encoded octet
string with the following meaning:
octet 0 - octet string format version, which identifies
the format of this string.
If format version octet has the value 1, the octets after
the version octet have the following meaning:
octet 1 - expansion board type, HUNDRED_MEG_1PORT=1,
HUNDRED_MEG_2PORT=2, HUNDRED_MEG_1PORT_COPPER=3,
HUNDRED_MEG_2PORT_COPPER=4, HUNDRED_MEG_2PORT_LX=5,
GIGA_1PORT=8, GIGA_2PORT=9
octet 2 - fiber port type, NONFIBER=0, SX_FIBER=1,
LX_FIBER=2, LHX_FIBER=3, LX_SX_FIBER=4
(It is obsoleted for Chassis Product)"
::= { snChasGen 14 }
snChasSpeedLeds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch port.
The maximum number of ports in one chassis is 24
that means 24 Ports Speed LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
--------- -------
0 10 MBit
1 100 MBit
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
---------"
::= { snChasGen 15 }
snChasEnableFanTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate fan failure traps."
DEFVAL { enabled }
::= { snChasGen 16 }
snChasIdNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An administratively-assigned chassis identity number,
used by inventory control."
::= { snChasGen 17 }
snChasActualTemperature OBJECT-TYPE
SYNTAX INTEGER (-110..250)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature of the chassis. Each unit is 0.5 degrees Celcius.
Only management module built with temperature sensor hardware
is applicable. For those non-applicable management module, it
returns no-such-name."
::= { snChasGen 18 }
snChasWarningTemperature OBJECT-TYPE
SYNTAX INTEGER (0..250)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actual temperature higher than this threshold value will trigger
the switch to send a temperature warning trap. Each unit is 0.5
degrees Celcius. Only management module built with temperature
sensor hardware is applicable. For those non-applicable management
module, it returns no-such-name."
::= { snChasGen 19 }
snChasShutdownTemperature OBJECT-TYPE
SYNTAX INTEGER (0..250)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Actual temperature higher than this threshold value will shutdown
a partial of the switch hardware to cool down the system. Each unit
is 0.5 degrees Celcius. Only management module built with temperature
sensor hardware is applicable. For those non-applicable management
module, it returns no-such-name."
::= { snChasGen 20 }
snChasEnableTempWarnTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate temperature warning traps."
DEFVAL { enabled }
::= { snChasGen 21 }
-- Flash Card
snChasFlashCard OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
flash card status. This is a packed bit string. The
status of each flash card is encoded into one bit.
bit value meaning
--------- -------
0 flash card absent.
1 flash card present.
There are up to two flash cards in this release.
This object is valid if M4 management module is present.
The following shows the meaning of each bit:
(bit 0 is the least significant bit).
bit position meaning
------------ -------
2-31 reserved
1 flash card 2 status
0 flash card 1 status"
::= { snChasGen 22 }
snChasFlashCardLeds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
flash card LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each flash card.
bit value meaning
-------- ---------
0 off
1 on
"
::= { snChasGen 23 }
snChasNumSlots OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of slots of the chassis."
::= { snChasGen 24 }
snChasArchitectureType OBJECT-TYPE
SYNTAX INTEGER {
stackable(1), -- old stackable
bigIron(2),
terathon(3), -- MG-8, NI-40G, IMR
fifthGen(4) -- XMR, MLX, RX
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Architecture type."
::= { snChasGen 25 }
snChasProductType OBJECT-TYPE
SYNTAX INTEGER {
invalid(0),
mg8(1),
ni40G(2),
imr(3),
biRx800(4),
niXmr16000(5),
biRx400(6),
niXmr8000(7),
biRx200(8),
niXmr4000(9),
niMlx16(10),
niMlx8(11),
niMlx4(12),
niMlx32(13),
niXmr32000(14),
biRx32(15),
niCES2000Series(16),
niCER2000Series(17),
brMlxE4(18),
brMlxE8(19),
brMlxE16(20),
brMlxE32(21),
biNI2(50),
biBB(66),
biM4(77),
biNI(78),
biSLB(83),
biWG(87)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Product type."
::= { snChasGen 26 }
snChasSystemMode OBJECT-TYPE
SYNTAX INTEGER {
xmr(1),
mlx(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System Mode. This object is only applicable to XMR/MLX/MLXe products.
For example, if snChasProductType is niMlx4/niMlx8/niMlx16/niMlx32 then the
this object returns mlx(2). If snChasProductType is niXmr4000/niXmr8000
niXmr160000/niXmr32000 this object returns xmr(1). If snChasProductType
is brMlxE4/brMlxE8/brMlxE16/brMlxE32 this object
returns either xmr(1) or mlx(2) depending on the mode of the system.
This object is not supported for the other products."
::= { snChasGen 27 }
snChasFactoryPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Factory Part number assigned by the manufacturer."
::= { snChasGen 28 }
snChasFactorySerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Factory serial number assigned by the manufacturer."
::= { snChasGen 29 }
-- Power Supply Table
snChasPwrSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnChasPwrSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of each power supply information. Only installed
power supply appears in a table row."
::= { snChasPwr 1 }
snChasPwrSupplyEntry OBJECT-TYPE
SYNTAX SnChasPwrSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the power supply table."
INDEX { snChasPwrSupplyIndex }
::= { snChasPwrSupplyTable 1 }
SnChasPwrSupplyEntry ::= SEQUENCE {
snChasPwrSupplyIndex
Integer32,
snChasPwrSupplyDescription
DisplayString,
snChasPwrSupplyOperStatus
INTEGER
}
snChasPwrSupplyIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to power supply table."
::= { snChasPwrSupplyEntry 1 }
snChasPwrSupplyDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power supply description string."
::= { snChasPwrSupplyEntry 2 }
snChasPwrSupplyOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
normal(2),
failure(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power supply operation status."
::= { snChasPwrSupplyEntry 3 }
-- Stacking Power Supply Table
snChasPwrSupply2Table OBJECT-TYPE
SYNTAX SEQUENCE OF SnChasPwrSupply2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of each power supply information for each unit. Only installed
power supply appears in a table row."
::= { snChasPwr 2 }
snChasPwrSupply2Entry OBJECT-TYPE
SYNTAX SnChasPwrSupply2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the power supply table."
INDEX { snChasPwrSupply2Unit, snChasPwrSupply2Index }
::= { snChasPwrSupply2Table 1 }
SnChasPwrSupply2Entry ::= SEQUENCE {
snChasPwrSupply2Unit
Integer32,
snChasPwrSupply2Index
Integer32 ,
snChasPwrSupply2Description
DisplayString,
snChasPwrSupply2OperStatus
INTEGER
}
snChasPwrSupply2Unit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to power supply table."
::= { snChasPwrSupply2Entry 1 }
snChasPwrSupply2Index OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to power supply table."
::= { snChasPwrSupply2Entry 2}
snChasPwrSupply2Description OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power supply description string."
::= { snChasPwrSupply2Entry 3 }
snChasPwrSupply2OperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
normal(2),
failure(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power supply operation status."
::= { snChasPwrSupply2Entry 4 }
-- Fan Table
snChasFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnChasFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of each fan information. Only installed
fan appears in a table row."
::= { snChasFan 1 }
snChasFanEntry OBJECT-TYPE
SYNTAX SnChasFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the fan table."
INDEX { snChasFanIndex }
::= { snChasFanTable 1 }
SnChasFanEntry ::= SEQUENCE {
snChasFanIndex
Integer32,
snChasFanDescription
DisplayString,
snChasFanOperStatus
INTEGER
}
snChasFanIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to fan table."
::= { snChasFanEntry 1 }
snChasFanDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fan description string."
::= { snChasFanEntry 2 }
snChasFanOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
normal(2),
failure(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fan operation status."
::= { snChasFanEntry 3 }
-- Stacking Fan Table
snChasFan2Table OBJECT-TYPE
SYNTAX SEQUENCE OF SnChasFan2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of each fan information for each unit. Only installed
fan appears in a table row."
::= { snChasFan 2 }
snChasFan2Entry OBJECT-TYPE
SYNTAX SnChasFan2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the fan table."
INDEX { snChasFan2Unit, snChasFan2Index }
::= { snChasFan2Table 1 }
SnChasFan2Entry ::= SEQUENCE {
snChasFan2Unit
Integer32,
snChasFan2Index
Integer32,
snChasFan2Description
DisplayString,
snChasFan2OperStatus
INTEGER
}
snChasFan2Unit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to fan table."
::= { snChasFan2Entry 1 }
snChasFan2Index OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to fan table."
::= { snChasFan2Entry 2 }
snChasFan2Description OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fan description string."
::= { snChasFan2Entry 3 }
snChasFan2OperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
normal(2),
failure(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fan operation status."
::= { snChasFan2Entry 4 }
-- Stacking Chassis unit Information
snChasUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnChasUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of chassis information for each unit. Only active
chassis appears in a table row."
::= { snChasUnit 1 }
snChasUnitEntry OBJECT-TYPE
SYNTAX SnChasUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the chassis table."
INDEX { snChasUnitIndex }
::= { snChasUnitTable 1 }
SnChasUnitEntry ::= SEQUENCE {
snChasUnitIndex
Integer32,
snChasUnitSerNum
DisplayString,
snChasUnitNumSlots
Integer32,
snChasUnitActualTemperature
INTEGER,
snChasUnitWarningTemperature
INTEGER,
snChasUnitShutdownTemperature
INTEGER,
snChasUnitPartNum
DisplayString
}
snChasUnitIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to chassis table."
::= { snChasUnitEntry 1 }
snChasUnitSerNum OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of the chassis for each unit. If the
serial number is unknown or unavailable then
the value should be a zero length string."
::= { snChasUnitEntry 2 }
snChasUnitNumSlots OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of slots of the chassis for each unit."
::= { snChasUnitEntry 3 }
snChasUnitActualTemperature OBJECT-TYPE
SYNTAX INTEGER (-110..250)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature of the chassis. Each unit is 0.5 degrees Celcius.
Only management module built with temperature sensor hardware
is applicable. For those non-applicable management module, it
returns no-such-name."
::= { snChasUnitEntry 4 }
snChasUnitWarningTemperature OBJECT-TYPE
SYNTAX INTEGER (0..250)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual temperature higher than this threshold value will trigger
the switch to send a temperature warning trap. Each unit is 0.5
degrees Celcius. Only management module built with temperature
sensor hardware is applicable. For those non-applicable management
module, it returns no-such-name."
::= { snChasUnitEntry 5 }
snChasUnitShutdownTemperature OBJECT-TYPE
SYNTAX INTEGER (0..250)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual temperature higher than this threshold value will shutdown
a partial of the switch hardware to cool down the system. Each unit
is 0.5 degrees Celcius. Only management module built with temperature
sensor hardware is applicable. For those non-applicable management
module, it returns no-such-name."
::= { snChasUnitEntry 6 }
snChasUnitPartNum OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part number of the chassis for each unit. If the
part number is unknown or unavailable then
the value should be a zero length string."
::= { snChasUnitEntry 7 }
-- Agent Groups
snAgentGbl OBJECT IDENTIFIER ::= { snAgentSys 1 }
snAgentBrd OBJECT IDENTIFIER ::= { snAgentSys 2 }
snAgentTrp OBJECT IDENTIFIER ::= { snAgentSys 3 }
snAgentBoot OBJECT IDENTIFIER ::= { snAgentSys 4 }
snAgCfgEos OBJECT IDENTIFIER ::= { snAgentSys 5 }
snAgentLog OBJECT IDENTIFIER ::= { snAgentSys 6 }
snAgentSysParaConfig OBJECT IDENTIFIER ::= { snAgentSys 7 }
snAgentConfigModule OBJECT IDENTIFIER ::= { snAgentSys 8 }
snAgentUser OBJECT IDENTIFIER ::= { snAgentSys 9 }
snAgentRedundant OBJECT IDENTIFIER ::= { snAgentSys 10 }
snAgentCpu OBJECT IDENTIFIER ::= { snAgentSys 11 }
snAgentHw OBJECT IDENTIFIER ::= { snAgentSys 12 }
snAgentTemp OBJECT IDENTIFIER ::= { snAgentSys 13 }
snAgentPoe OBJECT IDENTIFIER ::= { snAgentSys 14 }
snAgentLicense OBJECT IDENTIFIER ::= { snAgentSys 15 }
brcdSw OBJECT IDENTIFIER ::= { snAgentSys 16 }
brcdSwPackageGroup OBJECT IDENTIFIER ::= { brcdSw 1 }
brcdSwPackageUpgrade OBJECT IDENTIFIER ::= { brcdSwPackageGroup 1 }
brcdSwIntfModAutoUpgrade OBJECT IDENTIFIER ::= { brcdSwPackageGroup 2 }
-- SECTION 2: MIB Objects
-- Agent's Global Group
snAgReload OBJECT-TYPE
SYNTAX INTEGER {
other(1),
running(2),
reset(3),
busy(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action object to reboot the agent.
The following values can only be read:
other(1).....agent in unknown or other state
running(2)...agent running
busy(4).......reload not allowed at this time, flash is busy
The following value can be written:
reset(3).....do a hard reset
The agent will return a
response before the action occurs."
::= { snAgentGbl 1 }
snAgEraseNVRAM OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
error(2),
erase(3),
erasing(4),
busy(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action object to erase NVRAM of the agent.
The following values can only be read:
normal(1)
error(2)... operation failed or bad flash
erasing(4)...agent is erasing NVRAM flash
busy(5).......operation not allowed at this time, flash is busy
The following value can be written:
erase(3).....do erase
The agent will return a response even before the erase is done.
And the read value will be erasing until erase is done.
And the erase request will be rejected until error or normal."
::= { snAgentGbl 2 }
snAgWriteNVRAM OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
error(2),
write(3),
writing(4),
busy(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action object to save all configuration info to
NVRAM of the agent.
The following values can only be read:
normal(1)
error(2)... operation failed or bad flash
writing(4)...agent is writing NVRAM flash
busy(5).......operation not allowed at this time, flash is busy
The following value can be written:
write(3).....do write
The agent will return a response even before the write is done.
And the read value will be writing until write is done.
And the write request will be rejected until error or normal."
::= { snAgentGbl 3 }
snAgConfigFromNVRAM OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
error(2),
config(3),
configing(4),
busy(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is no more supported by FastIron and NetIron agents and
should not be used.
Action object to config the switch from NVRAM of the agent.
The following values can only be read:
normal(1)
error(2)... operation failed or bad flash
configing(4)...configing from NVRAM flash is in process.
busy(5).......operation not allowed at this time, flash is busy
The following value can be written:
config(3).....do config
The agent will return a response after config is done."
::= { snAgentGbl 4 }
-- image and config file down/up load
-- snAgTftpServerIp object is deprecated, and added following 2 new objects.
-- 1. "snAgTftpServerAddrType" represents Ipv4 and Ipv6 address types
-- 2. "snAgTftpServerAddr" reprasents Ipv4 and Ipv6 addresses
snAgTftpServerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The tftp server address, this will be used for both download/upload
image file and config file."
::= { snAgentGbl 5 }
snAgImgFname OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the image file including path currently associated
with the system. When the object is not used, the value is a
zero length string."
::= { snAgentGbl 6 }
snAgImgLoad OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
flashPrepareReadFailure(2),
flashReadError(3),
flashPrepareWriteFailure(4),
flashWriteError(5),
tftpTimeoutError(6),
tftpOutOfBufferSpace(7),
tftpBusy(8),
tftpRemoteOtherErrors(9),
tftpRemoteNoFile(10),
tftpRemoteBadAccess(11),
tftpRemoteDiskFull(12),
tftpRemoteBadOperation(13),
tftpRemoteBadId(14),
tftpRemoteFileExists(15),
tftpRemoteNoUser(16),
operationError(17),
loading(18),
uploadMPPrimary(19),
downloadMPPrimary(20),
uploadMPSecondary(21),
downloadMPSecondary(22),
tftpWrongFileType(23),
downloadSPPrimary(24),
downloadSPSecondary(25),
uploadMPBootROM(26),
downloadMPBootROM(27),
uploadMPBootTFTP(28),
downloadMPBootTFTP(29),
uploadMPMonitor(30),
downloadMPMonitor(31),
downloadSPBootROM(32)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action object to down/up load a new image
to the agent. The following values:
Error values: from normal(1) to operationError(17) and tftpWrongFileType(23).
loading(18) .. operation is in process.
The following values are used for set :
uploadMPPrimary(19)..upload the Primary image from MP flash to tftp server.
downloadMPPrimary(20)..download the Primary image from tftp server to MP flash.
uploadMPSecondary(21)..upload the Secondary image from MP flash to tftp server.
downloadMPSecondary(22)..download the Secondary image from tftp server to MP flash.
downloadSPPrimary(24)..download the Primary image from tftp server to SP flash.
downloadSPSecondary(25)..download the Secondary image from tftp server to SP flash.
uploadMPBootROM(26)..upload the Boot from flash image from MP flash to tftp server.
downloadMPBootROM(27)..download the Boot from flash image from tftp server to MP flash.
uploadMPBootTFTP(28)..upload the Boot from TFTP image from MP flash to tftp server.
downloadMPBootTFTP(29)..download the Boot from TFTP image from tftp server to MP flash.
uploadMPMonitor(30)..upload the Monitor image from MP flash to tftp server.
downloadMPMonitor(31)..download the Monitor image from tftp server to MP flash.
downloadSPBootROM(32)..download the Boot image from tftp server to SP flash.
MP is the management processor, SP is the switch processor.
The image filename is defined in
snAgImgFname. The tftp server address is defined in snAgTftpServerIp.
Atomic set of snAgImgLoad, snAgImgFname and
snAgTftpServerIp is required to allow down/up load to happen.
And the write request will be rejected during loading until error
or normal."
::= { snAgentGbl 7 }
snAgCfgFname OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the config file(s) including path currently associated
with the system. Some agents in special
situations may support a value which contains
multiple file names instead of a single file
name. Multiple names are specified as a list
of file names separated by semicolons (;).
When the object is not used, the value is a
zero length string."
::= { snAgentGbl 8 }
snAgCfgLoad OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
flashPrepareReadFailure(2),
flashReadError(3),
flashPrepareWriteFailure(4),
flashWriteError(5),
tftpTimeoutError(6),
tftpOutOfBufferSpace(7),
tftpBusy(8),
tftpRemoteOtherErrors(9),
tftpRemoteNoFile(10),
tftpRemoteBadAccess(11),
tftpRemoteDiskFull(12),
tftpRemoteBadOperation(13),
tftpRemoteBadId(14),
tftpRemoteFileExists(15),
tftpRemoteNoUser(16),
operationError(17),
loading(18),
uploadFromFlashToServer(20),
downloadToFlashFromServer(21),
uploadFromDramToServer(22),
downloadToDramFromServer(23),
uploadFromFlashToNMS(24),
downloadToFlashFromNMS(25),
uploadFromDramToNMS(26),
downloadToDramFromNMS(27),
operationDoneWithNMS(28),
tftpWrongFileType(29),
downloadToDramFromServerOverwrite(30)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action object to down/up load a config image
to the agent. The following values can be
read :
Error values: from normal(1) to operationError(17) and tftpWrongFileType(29).
loading(18) .. operation is in process.
The following value can be used to set:
uploadFromFlashToServer(20)..upload the config from flash
to tftp server.
downloadToFlashFromServer(21)..download the config to flash
from tftp server.
uploadFromDramToServer(22)..upload the config from DRAM
to tftp server.
downloadToDramFromServer(23)..download the config to DRAM
from tftp server.
downloadToDramFromServerOverwrite(30)..download the config to DRAM
from tftp server, clear the running-config,
and overwrite with the new config.
The following value can be used to set:
uploadFromFlashToNMS(24)..upload the config from flash to NMS.
downloadToFlashFromNMS(25)..download the config to flash from NMS.
uploadFromDramToNMS(26)..upload the config from DRAM to NMS.
downloadToDramFromNMS(27)..download the config to DRAM from NMS.
The config filename is defined in
snAgCfgFname. The tftp server address is defined in snAgTftpServerIp.
Atomic set of snAgCfgLoad, snAgCfgFname and snAgTftpServerIp is
required to allow down/up load to happen. And the write request
will be rejected during loading until error or normal.
For those NMS commands from (24) to (27), The snAgCfgEosTable MIB must
be sent along in one PDU. A seperate write memory cli or set
snAgWriteNVRAM is required to save the config to NVRAM."
::= { snAgentGbl 9 }
-- default gateway ip address
snAgDefGwayIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default gateway (router) address."
::= { snAgentGbl 10 }
-- image version
snAgImgVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the running software in the form
'major.minor.maintenance[letters]'."
::= { snAgentGbl 11 }
snAgFlashImgVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the software image saved in local
storage such as flash memory in the form
'major.minor.maintenance[letters]'. If not
known or not available, then the value is
a zero length string."
::= { snAgentGbl 12 }
snAgGblIfIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interface ip address."
::= { snAgentGbl 13 }
snAgGblIfIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interface ip address mask."
::= { snAgentGbl 14 }
snAgGblPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..97))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System Security Access Password and this is only
allowed to use for setting but not for reading.
An SNMP-Get will get an null string.
By default, this object needs to be in the same PDU while
doing Set operation some critical SNMP objects.
If command 'no snmp-server pw-check' is configured on
the device, then this object is not needed in the PDU.
The value of this object depends on the authentication
method configured for SNMP.
If there's no AAA authentication configuration for SNMP,
this object will have the enable superuser password.
If the AAA authentication for SNMP is configured and has
leading method as enable or line, this object will have
the corresponding enable or line password.
If the switch has AAA authentication for SNMP operation,
and the method specified is one of local, TACACS+, or RADIUS,
this object will have format '<username> <password>'
(note one space character in between).
The max size allows concatenation of max 48 octets of
username and 48 octets of password, with one blank character"
::= { snAgentGbl 15 }
snAgTrpRcvrCurEntry OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current total entries of the Trap
Receiver Table are created."
::= { snAgentGbl 16 }
snAgGblDataRetrieveMode OBJECT-TYPE
SYNTAX INTEGER {
nextbootCfg(0),
operationalData(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"By default, this mode is set to nextbootCfg(0).
The VLAN Table and Port-STP Table data will be retrieved
according to this mode.
nextbootCfg(0).........the nextboot configuration data are retrieved
operationalData(1)..........the current running data are retrieved"
::= { snAgentGbl 19 }
snAgSystemLog OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system log object to indicate whether any Network
Management Station(NMS) has login. The first byte
of the octet string is the value decribed below and
followed by 4 bytes of secret code.
login(1)..... a value for a NMS to login.
heartbeat(2)... a value for the login NMS periodically to
checkin; Otherwise, the Agent will automatically
set this object to logout(3) after a timeout
period.
logout(3).... a value for a NMS to logout.
changePassword(4).... a value for the login NMS to change
password, only if snAgGblPasswordChangeMode
was configured to 'anyMgmtEntity'.
changeReadOnlyCommunity(5).... a value for the login NMS
to change the read-only community string,
only if snAgGblPasswordChangeMode was
configured to 'anyMgmtEntity'.
changeReadWriteCommunity(6).... a value for the login NMS
to change the read-write community string,
only if snAgGblPasswordChangeMode was
configured to 'anyMgmtEntity'."
::= { snAgentGbl 20 }
snAgGblEnableColdStartTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate cold start traps."
DEFVAL { enabled }
::= { snAgentGbl 21 }
snAgGblEnableLinkUpTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate link up traps."
DEFVAL { enabled }
::= { snAgentGbl 22 }
snAgGblEnableLinkDownTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate link down traps."
DEFVAL { enabled }
::= { snAgentGbl 23 }
snAgGblPasswordChangeMode OBJECT-TYPE
SYNTAX INTEGER {
anyMgmtEntity(1),
consoleAndTelnet(2),
consoleOnly(3),
telnetOnly(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specify which management entity is allowed to change
the password. 'anyMgmtEntity' management entities are
SNMP management station, console command line interface,
and telnet command line interface. For security reason,
this object can only be modified by console command line
interface or telnet command line interface. The default
value is 'consoleAndTelnet', of which both console and
telnet command line interfaces are allowed to change
the password."
::= { snAgentGbl 24 }
snAgGblReadOnlyCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP read community string and this is only allowed
to use for setting but not for reading. An SNMP-Get
will get an zero length string.
Set operation on this object is allowed only if command
'password-change any' is configured on the target device."
::= { snAgentGbl 25 }
snAgGblReadWriteCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNMP read-write community string and this is only
allowed to use for setting but not for reading. An
SNMP-Get will get an zero length string.
Set operation on this object is allowed only if command
'password-change any' is configured on the target device."
::= { snAgentGbl 26 }
snAgGblCurrentSecurityLevel OBJECT-TYPE
SYNTAX INTEGER (0..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represnts the current log-in security level.
Each level of security requires a password to permit
user for different system configurations."
::= { snAgentGbl 27 }
snAgGblSecurityLevelSet OBJECT-TYPE
SYNTAX INTEGER (0..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This shows which the security level password to be set."
::= { snAgentGbl 28 }
snAgGblLevelPasswordsMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This shows the bitmap of level passwords which successfully assigned to the system."
::= { snAgentGbl 29 }
snAgGblQueueOverflow OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"false - The device queues are not overflow.
true - The device queues are overflow."
::= { snAgentGbl 30 }
snAgGblBufferShortage OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"false - The device buffers are adequate.
true - The device buffers are in shortage."
::= { snAgentGbl 31 }
snAgGblDmaFailure OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"false - The device DMAs are in good condition.
true - One of the DMAs in the device fails."
::= { snAgentGbl 32 }
snAgGblResourceLowWarning OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"false - No, the device does not have resource-low-warning.
true - Yes, the device does have resource-low-warning."
::= { snAgentGbl 33 }
snAgGblExcessiveErrorWarning OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"false - No, the device does not have any excessive collision, FCS errors, alignment warning etc.
true - Yes, the device does have."
::= { snAgentGbl 34 }
snAgGblCpuUtilData OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statistics collection of utilization of the CPU in the device.
In NetIron and FastIron platforms, reading this object resets all the counters.
Therefore, a user need not set snAgGblUtilCollect."
::= { snAgentGbl 35 }
snAgGblCpuUtilCollect OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"enable(1) - The beginning of statistics collection of utilization of the CPU in the device.
disable(0) - The end of statistics collection of utilization of the CPU in the device.
This object is deprecated. User need not set this object. User can read snAgGblCpuUtilData to reset all the counters. "
::= { snAgentGbl 36 }
snAgGblTelnetTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Telnet session idling timeout value. Each value unit is one minute.
FastIron and NetIron platforms support value upto 240 minutes.
On these platforms, value 0 means telnet sessions do not timeout."
::= { snAgentGbl 37 }
snAgGblEnableWebMgmt OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable web management."
DEFVAL { enabled }
::= { snAgentGbl 38 }
snAgGblSecurityLevelBinding OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represnts the binding of a given password to which
security level. A value of 255 indicates an invalid
binding."
::= { snAgentGbl 39 }
snAgGblEnableSLB OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enable/disable Server Load Balancing."
::= { snAgentGbl 40 }
snAgSoftwareFeature OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit string representing the software feature of the running
switch/router image. These features were conditional compiled
to different product images. For each bit, exist feature has
a value of 1, but non-exist feature has a value of 0.
octet 0, bit 0 - RMON
octet 0, bit 1 - ipx switching
octet 0, bit 2 - server load balancing
octet 0, bit 3 - layer 3 filter in switch
octet 0, bit 4 - ipx routing
octet 0, bit 5 - appletalk routing
octet 0, bit 6 - ip multicast routing
octet 0, bit 7 - local access control
octet 1, bit 0 - BGP routing
octet 1, bit 1 - loopback interface
octet 1, bit 2 - BigIron multi-management module
octet 1, bit 3 - BigIron SYSIF II
octet 1, bit 4 - BigIron POS support
octet 1, bit 5 - appletalk cable vlan
octet 1, bit 6 - 64 subnet
octet 1, bit 7 - multi-slot trunk
octet 2, bit 0 - TACACS
octet 2, bit 1 - Gigabit Ethernet port auto-negotiation mode
octet 2, bit 2 - FSRP
octet 2, bit 3 - Exodus requested OSPF enhancement
octet 2, bit 4 - OSPF NSSA
octet 2, bit 5 - POS
octet 2, bit 6 - QOS
octet 2, bit 7 - Single Span
octet 3, bit 0 - Fast Span
octet 3, bit 1 - Base L3
octet 3, bit 2 - static log buffer
octet 3, bit 3 - L2 POS
octet 3, bit 4 - BI15K
octet 3, bit 5 - L2 ATM
octet 3, bit 6 - ATM
octet 3, bit 7 - NETFLOW
octet 4, bit 0 - SFLOW
octet 4, bit 1 - GVRP
octet 4, bit 2 - GARP
octet 4, bit 3 - dynamic trunk
octet 4, bit 4 - IGC 8G
octet 4, bit 5 - rate limit
octet 4, bit 6 - IPC rate limit
octet 4, bit 7 - MPLS
octet 5, bit 0 - ISIS
octet 5, bit 1 - link aggregation
octet 5, bit 2 - port dual mode
octet 5, bit 3 - private vlan
octet 5, bit 4 - MBGP
octet 5, bit 5 - ipv6 protocol vlan
octet 5, bit 6 - X10G
octet 5, bit 7 - fastiron edge switch/router (gridiron)
octet 6, bit 0 - FDP
octet 6, bit 1 - port tag type
octet 6, bit 2 - wireless capable
octet 6, bit 3 - snSwPortVlanId object has changed from read-only to read-write
octet 6, bit 4 - LLDP
Bit 0 is the least significant bit of an octet, and
bit 7 is the most significant bit of an octet."
::= { snAgentGbl 41 }
snAgGblEnableModuleInsertedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the SNMP agent process is permitted to
generate hardware module inserted to chassis traps."
DEFVAL { enabled }
::= { snAgentGbl 42 }
snAgGblEnableModuleRemovedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the SNMP agent process is permitted to
generate hardware module removed from chassis traps."
DEFVAL { enabled }
::= { snAgentGbl 43 }
snAgGblTrapMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A generic trap message string."
::= { snAgentGbl 44 }
snAgGblEnableTelnetServer OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable telnet server in device."
DEFVAL { enabled }
::= { snAgentGbl 45 }
snAgGblTelnetPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Telnet Access Password and this is only
useful for write operation. A read operation
get a null string.
Set operation on this object is allowed only if command
'password-change any' is configured on the target device.
Another configuration affecting this is
'no snmp-server pw-check'. If its configured on the device,
there's no need to pass another varbind snAgGblPassword.
By default, 'snmp-server pw-check' is true, and thus needs
to have snAgGblPassword along with this object.
in the same Set PDU."
::= { snAgentGbl 46 }
snAgBuildDate OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date of the built software."
::= { snAgentGbl 47 }
snAgBuildtime OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time of the built software."
::= { snAgentGbl 48 }
snAgBuildVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The image label of the built software"
::= { snAgentGbl 49 }
snAgGblCpuUtil1SecAvg OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statistics collection of 1 second CPU utilization."
::= { snAgentGbl 50 }
snAgGblCpuUtil5SecAvg OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statistics collection of 5 second CPU utilization."
::= { snAgentGbl 51 }
snAgGblCpuUtil1MinAvg OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statistics collection of 1 minute CPU utilization."
::= { snAgentGbl 52 }
snAgGblDynMemUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The system dynamic memory utilization, in unit of percentage.
Deprecated: Refer to snAgSystemDRAMUtil.
For NI platforms, refer to snAgentBrdMemoryUtil100thPercent"
::= { snAgentGbl 53 }
snAgGblDynMemTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total amount of system dynamic memory, in number of bytes.
Deprecated: Refer to snAgSystemDRAMTotal.
For NI platforms, refer to snAgentBrdMemoryTotal"
::= { snAgentGbl 54 }
snAgGblDynMemFree OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The free amount of system dynamic memory, in number of bytes.
Deprecated: Refer to snAgSystemDRAMFree.
For NI platforms, refer to snAgentBrdMemoryAvailable"
::= { snAgentGbl 55 }
snAgImgLoadSPModuleType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
vm1(2),
pos12(3),
pos48(4),
atm(5),
gignpa(6),
lp(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The switch processor module type of which that receives
the downloaded image."
::= { snAgentGbl 56 }
snAgImgLoadSPModuleNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The slot numner of a switch processor module that receives
the downloaded image. Setting value 0 applies to all SP
modules."
::= { snAgentGbl 57 }
snAgTrapHoldTime OBJECT-TYPE
SYNTAX INTEGER (1..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in seconds for which traps will be witheld
during system initialization."
::= { snAgentGbl 58 }
snAgSFlowSourceInterface OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Use the ifIndex value here to specify the
source interface to be used for sFlow packets.
The interface should have IP address configured
on it. Value of 0 indicates that source interface
has not been configured for sFlow. Port 65534
is used to specify a null port."
::= { snAgentGbl 59 }
snAgGblTelnetLoginTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Telnet session login timeout value in minutes.
FastIron and NetIron platforms support value upto 10 minutes, and default of 1 minute."
::= { snAgentGbl 60 }
snAgGblBannerExec OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"EXEC process creation banner. Insert newlines using '\n' within the string."
::= { snAgentGbl 61 }
snAgGblBannerIncoming OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Incoming terminal line banner. Insert newlines using '\n' within the string."
::= { snAgentGbl 62 }
snAgGblBannerMotd OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Message-of-the-day banner. Insert newlines using '\n' within the string."
::= { snAgentGbl 63 }
snAgWebMgmtServerTcpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TCP port number of web management interface."
::= { snAgentGbl 64 }
-- image and config file down/up load
snAgTftpServerAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TFTP server IP address Type. Supported address types are ipv4(1) and ipv6(2)"
DEFVAL { ipv4 }
::= { snAgentGbl 65 }
snAgTftpServerAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TFTP server IP address."
::= { snAgentGbl 66 }
snAgGblDeleteFirstBeforeDownload OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to true deletes the existing target file on the
Management module flash. This object can be set to true only
when the snAgImgLoad is set to downloadMPPrimary(20),
downloadMPSecondary(22), downloadSPPrimary(24),
downloadSPSecondary(25) or downloadMPMonitor(31) in the same
SNMP set request PDU.
This object is reset to false after successful or unsuccessful
download of specified file to flash.
Reading this object returns false(2)."
::= { snAgentGbl 67 }
-- Agent Board Table
snAgentBrdTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentBrdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of each physical board information."
::= { snAgentBrd 1 }
snAgentBrdEntry OBJECT-TYPE
SYNTAX SnAgentBrdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the Agent Board table."
INDEX { snAgentBrdIndex }
::= { snAgentBrdTable 1 }
SnAgentBrdEntry ::= SEQUENCE {
snAgentBrdIndex
Integer32,
snAgentBrdMainBrdDescription
DisplayString,
snAgentBrdMainBrdId
OCTET STRING,
snAgentBrdMainPortTotal
Integer32,
snAgentBrdExpBrdDescription
DisplayString,
snAgentBrdExpBrdId
OCTET STRING,
snAgentBrdExpPortTotal
INTEGER,
snAgentBrdStatusLeds
Integer32,
snAgentBrdTrafficLeds
Integer32,
snAgentBrdMediaLeds
Integer32,
snAgentBrdSpeedLeds
Integer32,
snAgentBrdModuleStatus
INTEGER,
snAgentBrdRedundantStatus
INTEGER,
snAgentBrdAlarmLeds
Integer32,
snAgentBrdTxTrafficLeds
Integer32,
snAgentBrdRxTrafficLeds
Integer32,
snAgentBrdStatusLedString
OCTET STRING,
snAgentBrdTrafficLedString
OCTET STRING,
snAgentBrdMediaLedString
OCTET STRING,
snAgentBrdSpeedLedString
OCTET STRING,
snAgentBrdAlarmLedString
OCTET STRING,
snAgentBrdTxTrafficLedString
OCTET STRING,
snAgentBrdRxTrafficLedString
OCTET STRING,
snAgentBrdMemoryTotal
CounterBasedGauge64,
snAgentBrdMemoryAvailable
CounterBasedGauge64,
snAgentBrdSerialNumber
DisplayString,
snAgentBrdPartNumber
DisplayString,
snAgentBrdMemoryUtil100thPercent
Unsigned32
}
snAgentBrdIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to the Agent Interface Table."
::= { snAgentBrdEntry 1 }
snAgentBrdMainBrdDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main board description string."
::= { snAgentBrdEntry 2 }
snAgentBrdMainBrdId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main board identifier, which can uniquely identify a board
type. It is an encoded octet string with the following meaning:
octet 0 - octet string format version, which identifies the
format of this string.
If format version octet has the value 2, the octets after the
version octet have the following meaning:
octet 1 - product type:
BI_WG 0x57
BI_BB 0x42
BI_NI 0x4E
BI_NI2 0x32
NI_M4 0x4D
BI_SLB 0x53
octet 2 - module type:
MASTER_FIBER_8G 0x0
MASTER_FIBER_4G 0x1
MASTER_COPPER_16 0x2
SLAVE_FIBER_4G 0x3
FI_MASTER_FIBER_2G 0x4
FI_MASTER_FIBER_4G 0x5
MASTER_COPPER_8G 0x6
FI_MASTER_FIBER_8G 0x7
SLAVE_FIBER_8G 0x8
MASTER_COPPER_12_2 0x9
SLAVE_COPPER_24 0xA
FI_SLAVE_COPPER_24 0xB
SLAVE_100FX_8 0xD
SLAVE_100FX_16 0xC
SLAVE_COPPER_8G 0xE
SLAVE_COPPER_16_2 0xF
STACK_FIBER_8G 0x10
STACK_COPPER_8G 0x11
MASTER_FIBER_2G 0x12
SLAVE_100FX_24 0x13
MASTER_FIBER_0G 0x14
POS_622M 0x15
POS_155M 0x16
SLAVE_FIBER_2G 0x17
SLAVE_COPPER_2G 0x18
FI_SLAVE_FIBER_2G 0x19
FI_SLAVE_FIBER_4G 0x1A
FI_SLAVE_FIBER_8G 0x1B
FI_SLAVE_COPPER_8G 0x1C
FI_MASTER_COPPER_8G 0x1D
POS_155M2P 0x1E
FI_MASTER_COPPER_4G 0x1F
FI_MASTER_COPPER_2G 0x20
MASTER_COPPER_4G 0x21
MASTER_COPPER_2G 0x22
MASTER_M4_8G 0x23
MASTER_M4_4G 0x24
MASTER_M4_2G 0x25
MASTER_M4_0G 0x26
MASTER_M5_0G 0x27
POS_2488M 0x28
SLAVE_M5_0G 0x29
POS_N2488M 0x2A
STACK_IPC_48_2 0x2B
SLAVE_NPA_FIBER_4G 0x2C
ATM_2PORT 0x2D
ATM_4PORT 0x2E
SLAVE_FIBER_10G 0x2F
STACK_FES_48_2 0x30
STACK_FES_24_2 0x31
STACK_FES_96_4 0x32
STACK_FES_12G 0x33
STACK_FESX_24G 0x34
STACK_FESX_24_2_G 0x35
STACK_FESX_24_1_G 0x36
STACK_FESX_48G 0x37
STACK_FESX_48_2_G 0x38
STACK_FESX_48_1_G 0x39
SUPERX_FI_MGMT 0x40
SUPERX_FI_2P10G 0x41
SUPERX_FI_24GC 0x42
SUPERX_FI_24GF 0x43
SUPERX_FI_2P10G_WAN 0x44
SUPERX_FI_MGMT_II 0x4a
SLAVE_JC_48E 0xC3
SLAVE_JC_48T 0xC4
MASTER_JC_M4_8G 0xC5
SLAVE_JC_8G 0xC6
SLAVE_JC_B16GF 0xC8
MASTER_JC_B2404 0xC9
SLAVE_JC_B16GC 0xCA
SLAVE_JC_B24FX 0xCE
octet 3 - processor type, PVR_M603=3, PVR_M604=4, PVR_M603E=6,
PVR_M603EV=7, PVR_M750=8, PVR_M604E=9, PVR_M8245=81
octet 4 to
octet 5 - processor speed in MHz
octet 6 - MAC type:
MAC_NONE=0
MAC_SEEQ_10_100=1,
MAC_DEC_10_100=2,
MAC_3COM_10_100=3,
MAC_X10GMAC_10000=4,
MAC_SEEQ_1000=5,
MAC_GMAC_1000=6,
MAC_VLSI_1000=7
octet 7 - PHY type, PHY_NONE=0, PHY_QSI=1, PHY_BROADCOM=2,
PHY_ICS=3, PHY_NATIONAL=4, PHY_LEVEL1=6,
PHY_BROADCOM_10_100=7, PHY_LEVEL24=8,
PHY_BROADCOM_10000=9 (for 10G),
PHY_3COM_10_100=9 (for others)
octet 8 - port type, COPPER=0, FIBER=1
octet 9 - fiber port type, NONFIBER=0, SX_FIBER=1,
LX_FIBER=2, LHX_FIBER=3, LX_SX_FIBER=4,
LHB_FIBER=5
octet 10 to
octet 13 - DRAM size in KBytes
octet 14 to
octet 17 - boot flash size in KBytes
octet 18 to
octet 21 - code flash size in KBytes
octet 22 to
octet 27 - serial number.
octet 28 - chassis backplane type.
chassis4000 = 0x00
chassis8000 = 0x02
chassis15000 = 0x01
chassisFISX = 0x04
Turbo8 = 0x07 (stack2)
FastIron2 = 0x06 (stack1)"
::= { snAgentBrdEntry 3 }
snAgentBrdMainPortTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of ports for the main board."
::= { snAgentBrdEntry 4 }
snAgentBrdExpBrdDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The expansion board description string. Expansion
board are those boards attaching on the main board."
::= { snAgentBrdEntry 5 }
snAgentBrdExpBrdId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The expansion board identifier. Expansion board are those
boards attaching on the main board. It is an encoded octet
string with the following meaning:
octet 0 - octet string format version, which identifies
the format of this string.
If format version octet has the value 1, the octets after
the version octet have the following meaning:
octet 1 - expansion board type, HUNDRED_MEG_1PORT=1,
HUNDRED_MEG_2PORT=2, HUNDRED_MEG_1PORT_COPPER=3,
HUNDRED_MEG_2PORT_COPPER=4, HUNDRED_MEG_2PORT_LX=5,
GIGA_1PORT=8, GIGA_2PORT=9
octet 2 - fiber port type, NONFIBER=0, SX_FIBER=1,
LX_FIBER=2, LHX_FIBER=3, LX_SX_FIBER=4, LHB_FIBER=5"
::= { snAgentBrdEntry 6 }
snAgentBrdExpPortTotal OBJECT-TYPE
SYNTAX INTEGER (0..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of ports for the expansion board."
::= { snAgentBrdEntry 7 }
snAgentBrdStatusLeds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"A bit array that contains the value of the
front panel status LEDs. This is a bit-map;
each LED is encoded into 1 bit for each switch
port. The maximum number of ports in one chassis
is 32 that means 32 Ports Status LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
-------- ---------
0 off (Link off)
1 on (Link on)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
(It was obsoleted after release 07100, replaced by snAgentBrdStatusLedString)"
::= { snAgentBrdEntry 8 }
snAgentBrdTrafficLeds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"A bit array that contains the value of the
front panel traffic LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch
port. The maximum number of ports in one chassis
is 24 that means 24 Ports Traffic LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
-------- ---------
0 off (no traffic)
1 on (traffic)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
(It was obsoleted after release 07100, replaced by snAgentBrdTrafficLedString)"
::= { snAgentBrdEntry 9 }
snAgentBrdMediaLeds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch port.
The maximum number of ports in one chassis is 24
that means 24 Ports Media LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
--------- -------
0 half duplex
1 full duplex
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
(It was obsoleted after release 07100, replaced by snAgentBrdMediaLedString)"
::= { snAgentBrdEntry 10 }
snAgentBrdSpeedLeds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch port.
The maximum number of ports in one chassis is 24
that means 24 Ports Speed LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
--------- -------
0 10 MBit
1 100 MBit
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
(It was obsoleted after release 07100, replaced by snAgentBrdSpeedLedString)"
::= { snAgentBrdEntry 11 }
snAgentBrdModuleStatus OBJECT-TYPE
SYNTAX INTEGER {
moduleEmpty(0),
moduleGoingDown(2),
moduleRejected(3),
moduleBad(4),
moduleConfigured(8),
moduleComingUp(9),
moduleRunning(10),
moduleBlocked(11)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"By default, this mode is set to notActivated(0).
moduleEmpty(0) ......... The slot of the chassis is empty.
moduleGoingDown(2) ..... The module is going down.
moduleRejected(3) ...... The module is being rejected due to wrong configuration.
moduleBad(4) ........... The module Hardware is bad.
moduleConfigured(8) ...... The module is configured (stacking)
moduleComingUp(9) ...... The module is in power-up cycle.
moduleRunning(10) ....... The module is running.
moduleBlocked(11) ....... The module is blocked, for full height card."
::= { snAgentBrdEntry 12 }
snAgentBrdRedundantStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
active(2),
standby(3),
crashed(4),
comingUp(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The redundant status of a module. Non-management module always
returns other(1). Management module returns the rest of the
states."
::= { snAgentBrdEntry 13 }
snAgentBrdAlarmLeds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs (for POS Module Only). This is a packed bit string;
each LED is encoded into 1 bit for each switch port.
The maximum number of ports in one chassis is 24
that means 24 Ports Speed LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
--------- -------
0 no alarm
1 alarm
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
(It was obsoleted after release 07100, replaced by snAgentBrdAlarmLedString)"
::= { snAgentBrdEntry 14 }
snAgentBrdTxTrafficLeds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"A bit array that contains the value of the
front panel transmit traffic LEDs (for POS Module Only). This is a packed bit string;
each LED is encoded into 1 bit for each switch
port. The maximum number of ports in one chassis
is 24 that means 24 Ports Transmit Traffic LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
-------- ---------
0 off (no transmit traffic)
1 on (transmit traffic)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
(It was obsoleted after release 07100, replaced by snAgentBrdTxTrafficLedString)"
::= { snAgentBrdEntry 15 }
snAgentBrdRxTrafficLeds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"A bit array that contains the value of the
front panel receive traffic LEDs (for POS Module Only). This is a packed bit string;
each LED is encoded into 1 bit for each switch
port. The maximum number of ports in one chassis
is 24 that means 24 Ports Receive Traffic LEDs. The expansion port
number always begins from the last main port number.
The following shows the meaning of each bit for each
switch port:
bit value meaning
-------- ---------
0 off (no receive traffic)
1 on (receive traffic)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
(It was obsoleted after release 07100, replaced by snAgentBrdRxTrafficLedString)"
::= { snAgentBrdEntry 16 }
snAgentBrdStatusLedString OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel status LEDs. This is a bit-map;
each LED is encoded into 1 bit for each switch
port. The following shows the meaning of each
bit for each switch port:
bit value meaning
-------- ---------
0 off (Link off)
1 on (Link on)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
--------"
::= { snAgentBrdEntry 17 }
snAgentBrdTrafficLedString OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel traffic LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch
port. The following shows the meaning of each
bit for each switch port:
bit value meaning
-------- ---------
0 off (no traffic)
1 on (traffic)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
--------"
::= { snAgentBrdEntry 18 }
snAgentBrdMediaLedString OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch port.
The following shows the meaning of each bit for each
switch port:
bit value meaning
--------- -------
0 half duplex
1 full duplex
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
---------"
::= { snAgentBrdEntry 19 }
snAgentBrdSpeedLedString OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs. This is a packed bit string;
each LED is encoded into 1 bit for each switch port.
The following shows the meaning of each bit for each
switch port:
bit value meaning
--------- -------
0 10 MBit
1 100 MBit
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
---------"
::= { snAgentBrdEntry 20 }
snAgentBrdAlarmLedString OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel media LEDs (for POS Module Only).
This is a packed bit string; each LED is encoded
into 1 bit for each switch port. The following
shows the meaning of each bit for each switch port:
bit value meaning
--------- -------
0 no alarm
1 alarm
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
---------"
::= { snAgentBrdEntry 21 }
snAgentBrdTxTrafficLedString OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel transmit traffic LEDs (for POS Module Only).
This is a packed bit string; each LED is encoded into
1 bit for each switch port. The following shows the
meaning of each bit for each switch port:
bit value meaning
-------- ---------
0 off (no transmit traffic)
1 on (transmit traffic)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
--------"
::= { snAgentBrdEntry 22 }
snAgentBrdRxTrafficLedString OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit array that contains the value of the
front panel receive traffic LEDs (for POS Module Only).
This is a packed bit string; each LED is encoded into
1 bit for each switch port. The following shows the
meaning of each bit for each switch port:
bit value meaning
-------- ---------
0 off (no receive traffic)
1 on (receive traffic)
The bitmap of LEDs are as following:
(Port1) (Port4) (Port8)
Bit (Bit0) (Bit3) (Bit7)
Byte 1: LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
Byte 2: LED9 LED10 LED11 LED12 LED13 LED14 LED15 LED16
Byte 3: LED17 LED18 LED19 LED20 LED21 LED22 LED23 LED24
--------"
::= { snAgentBrdEntry 23 }
snAgentBrdMemoryTotal OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total memory in bytes within this module."
::= { snAgentBrdEntry 24 }
snAgentBrdMemoryAvailable OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total memory in bytes available for use within this module."
::= { snAgentBrdEntry 25 }
snAgentBrdSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Board Serial number. Zero length string indicates that
module serial number has not been programmed within
EEPROM or the module does not support serial number within EEPROM."
::= { snAgentBrdEntry 26 }
snAgentBrdPartNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Board Part number. Zero length string indicates that
module part number has not been programmed within
EEPROM or the module does not support part number within EEPROM."
::= { snAgentBrdEntry 27 }
snAgentBrdMemoryUtil100thPercent OBJECT-TYPE
SYNTAX Unsigned32 (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Dynamic memory utilization within this module in units
of one-hundredth of a percent. "
::= { snAgentBrdEntry 28 }
-- Agent Stacking Board Table
snAgentBrd2Table OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentBrd2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of each physical board information for each unit."
::= { snAgentBrd 2 }
snAgentBrd2Entry OBJECT-TYPE
SYNTAX SnAgentBrd2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the Agent Board table."
INDEX { snAgentBrd2Unit, snAgentBrd2Slot }
::= { snAgentBrd2Table 1 }
SnAgentBrd2Entry ::= SEQUENCE {
snAgentBrd2Unit
Integer32,
snAgentBrd2Slot
Integer32,
snAgentBrd2MainBrdDescription
DisplayString,
snAgentBrd2MainBrdId
OCTET STRING,
snAgentBrd2MainPortTotal
Integer32,
snAgentBrd2ModuleStatus
INTEGER,
snAgentBrd2RedundantStatus
INTEGER
}
snAgentBrd2Unit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to the Agent module Table."
::= { snAgentBrd2Entry 1 }
snAgentBrd2Slot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to the Agent module Table."
::= { snAgentBrd2Entry 2 }
snAgentBrd2MainBrdDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main board description string."
::= { snAgentBrd2Entry 3}
snAgentBrd2MainBrdId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main board identifier, which can uniquely identify a board
type. It is an encoded octet string with the following meaning:
octet 0 - octet string format version, which identifies the
format of this string.
If format version octet has the value 2, the octets after the
version octet have the following meaning:
octet 1 - product type:
BI_WG 0x57
BI_BB 0x42
BI_NI 0x4E
BI_NI2 0x32
NI_M4 0x4D
BI_SLB 0x53
octet 2 - module type:
MASTER_FIBER_8G 0x0
MASTER_FIBER_4G 0x1
MASTER_COPPER_16 0x2
SLAVE_FIBER_4G 0x3
FI_MASTER_FIBER_2G 0x4
FI_MASTER_FIBER_4G 0x5
MASTER_COPPER_8G 0x6
FI_MASTER_FIBER_8G 0x7
SLAVE_FIBER_8G 0x8
MASTER_COPPER_12_2 0x9
SLAVE_COPPER_24 0xA
FI_SLAVE_COPPER_24 0xB
SLAVE_100FX_8 0xD
SLAVE_100FX_16 0xC
SLAVE_COPPER_8G 0xE
SLAVE_COPPER_16_2 0xF
STACK_FIBER_8G 0x10
STACK_COPPER_8G 0x11
MASTER_FIBER_2G 0x12
SLAVE_100FX_24 0x13
MASTER_FIBER_0G 0x14
POS_622M 0x15
POS_155M 0x16
SLAVE_FIBER_2G 0x17
SLAVE_COPPER_2G 0x18
FI_SLAVE_FIBER_2G 0x19
FI_SLAVE_FIBER_4G 0x1A
FI_SLAVE_FIBER_8G 0x1B
FI_SLAVE_COPPER_8G 0x1C
FI_MASTER_COPPER_8G 0x1D
POS_155M2P 0x1E
FI_MASTER_COPPER_4G 0x1F
FI_MASTER_COPPER_2G 0x20
MASTER_COPPER_4G 0x21
MASTER_COPPER_2G 0x22
MASTER_M4_8G 0x23
MASTER_M4_4G 0x24
MASTER_M4_2G 0x25
MASTER_M4_0G 0x26
MASTER_M5_0G 0x27
POS_2488M 0x28
SLAVE_M5_0G 0x29
POS_N2488M 0x2A
STACK_IPC_48_2 0x2B
SLAVE_NPA_FIBER_4G 0x2C
ATM_2PORT 0x2D
ATM_4PORT 0x2E
SLAVE_FIBER_10G 0x2F
STACK_FES_48_2 0x30
STACK_FES_24_2 0x31
STACK_FES_96_4 0x32
STACK_FES_12G 0x33
STACK_FESX_24G 0x34
STACK_FESX_24_2_G 0x35
STACK_FESX_24_1_G 0x36
STACK_FESX_48G 0x37
STACK_FESX_48_2_G 0x38
STACK_FESX_48_1_G 0x39
SUPERX_FI_MGMT 0x40
SUPERX_FI_2P10G 0x41
SUPERX_FI_24GC 0x42
SUPERX_FI_24GF 0x43
SUPERX_FI_2P10G_WAN 0x44
SUPERX_FI_MGMT_II 0x4a
SLAVE_JC_48E 0xC3
SLAVE_JC_48T 0xC4
MASTER_JC_M4_8G 0xC5
SLAVE_JC_8G 0xC6
SLAVE_JC_B16GF 0xC8
MASTER_JC_B2404 0xC9
SLAVE_JC_B16GC 0xCA
octet 3 - processor type, PVR_M603=3, PVR_M604=4, PVR_M603E=6,
PVR_M603EV=7, PVR_M750=8, PVR_M604E=9, PVR_M8245=81
octet 4 to
octet 5 - processor speed in MHz
octet 6 - MAC type:
MAC_NONE=0
MAC_SEEQ_10_100=1,
MAC_DEC_10_100=2,
MAC_3COM_10_100=3,
MAC_X10GMAC_10000=4,
MAC_SEEQ_1000=5,
MAC_GMAC_1000=6,
MAC_VLSI_1000=7
octet 7 - PHY type, PHY_NONE=0, PHY_QSI=1, PHY_BROADCOM=2,
PHY_ICS=3, PHY_NATIONAL=4, PHY_LEVEL1=6,
PHY_BROADCOM_10_100=7, PHY_LEVEL24=8,
PHY_BROADCOM_10000=9 (for 10G),
PHY_3COM_10_100=9 (for others)
octet 8 - port type, COPPER=0, FIBER=1
octet 9 - fiber port type, NONFIBER=0, SX_FIBER=1,
LX_FIBER=2, LHX_FIBER=3, LX_SX_FIBER=4,
LHB_FIBER=5
octet 10 to
octet 13 - DRAM size in KBytes
octet 14 to
octet 17 - boot flash size in KBytes
octet 18 to
octet 21 - code flash size in KBytes
octet 22 to
octet 27 - serial number.
octet 28 - chassis backplane type.
chassis4000 = 0x00
chassis8000 = 0x02
chassis15000 = 0x01
chassisFISX = 0x04
Turbo8 = 0x07 (stack2)
FastIron2 = 0x06 (stack1)"
::= { snAgentBrd2Entry 4 }
snAgentBrd2MainPortTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of ports for the main board."
::= { snAgentBrd2Entry 5 }
snAgentBrd2ModuleStatus OBJECT-TYPE
SYNTAX INTEGER {
moduleEmpty(0),
moduleGoingDown(2),
moduleRejected(3),
moduleBad(4),
moduleConfigured(8),
moduleComingUp(9),
moduleRunning(10),
moduleBlocked(11)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"By default, this mode is set to notActivated(0).
moduleEmpty(0) ......... The slot of the chassis is empty.
moduleGoingDown(2) ..... The module is going down.
moduleRejected(3) ...... The module is being rejected due to wrong configuration.
moduleBad(4) ........... The module Hardware is bad.
moduleConfigured(8) ...... The module is configured (stacking)
moduleComingUp(9) ...... The module is in power-up cycle.
moduleRunning(10) ....... The module is running.
moduleBlocked(11) ....... The module is blocked, for full height card."
::= { snAgentBrd2Entry 6 }
snAgentBrd2RedundantStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
active(2),
standby(3),
crashed(4),
comingUp(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The redundant status of a module. Non-management module always
returns other(1). Management module returns the rest of the
states."
::= { snAgentBrd2Entry 7}
-- Trap Receiver Table
-- Trap Receiver Table
-- snAgTrpRcvrTable is deprecated, replaced by fdryTrapReceiverTable.
-- The new table "fdryTrapReceiverTable" combines Ipv4 and Ipv6 configuration of
-- trap Receiver/managers which to send traps.
snAgTrpRcvrTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgTrpRcvrEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A table of managers which to send traps."
::= { snAgentTrp 1 }
snAgTrpRcvrEntry OBJECT-TYPE
SYNTAX SnAgTrpRcvrEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A row in the trap receiver table.
The column snAgTrpRcvrStatus is used to create
and delete rows in the table. Creation requires
a SET PDU with objects snAgTrpRcvrIndex,
snAgTrpRcvrIpAddr, snAgTrpRcvrComm and
snAgTrpRcvrStatus."
INDEX { snAgTrpRcvrIndex }
::= { snAgTrpRcvrTable 1 }
SnAgTrpRcvrEntry ::= SEQUENCE {
snAgTrpRcvrIndex
Integer32,
snAgTrpRcvrIpAddr
IpAddress,
snAgTrpRcvrCommunityOrSecurityName
OCTET STRING,
snAgTrpRcvrStatus
INTEGER,
snAgTrpRcvrUDPPort
INTEGER,
snAgTrpRcvrSecurityModel
INTEGER,
snAgTrpRcvrSecurityLevel
INTEGER
}
snAgTrpRcvrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The index to the Trap Receiver Table."
::= { snAgTrpRcvrEntry 1 }
snAgTrpRcvrIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The ip address for
SNMP manager that is to receive the trap."
::= { snAgTrpRcvrEntry 2 }
snAgTrpRcvrCommunityOrSecurityName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Community string to use. In case of USM (SNMPv3) security model,
this object is used to provide the security name."
::= { snAgTrpRcvrEntry 3 }
snAgTrpRcvrStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4),
ignore(5)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object is used to create and
delete rows in the table and control
if they are used. The values
that can be written are:
ignore(5)...don't use this entry to
send traps to at this time
delete(3)...deletes the row
create(4)...creates a new row
If the row exists, then a SET with
value of create(5) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
other(1)....some other case
valid(2)....the row exists and is valid
ignore(5)...don't use this entry to
send traps to at this time"
::= { snAgTrpRcvrEntry 4 }
snAgTrpRcvrUDPPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"UDP port number of the trap receiver."
DEFVAL { 162 }
::= { snAgTrpRcvrEntry 5 }
snAgTrpRcvrSecurityModel OBJECT-TYPE
SYNTAX INTEGER {
v1(1),
v2c(2),
usm(3)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Version of trap format to be used."
DEFVAL { 1 }
::= { snAgTrpRcvrEntry 6 }
snAgTrpRcvrSecurityLevel OBJECT-TYPE
SYNTAX INTEGER {
noAuth(1),
auth(2),
authPriv(3)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Used for USM (SNMPv3) security model to specify the level of security.
The security name is provided by snAgTrpRcvrCommunityOrSecurityName."
DEFVAL { 1 }
::= { snAgTrpRcvrEntry 7 }
-- Boot Sequence Table
snAgBootSeqTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgBootSeqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of image load sequnce instructions to the boot code.
Boot code will start from instruction of the first valid entry
to load the image. If failed, it will use the second valid
entry and so on, until a succesful load has completed. Each
entry must have an unique instruction, duplicate instructions
will be rejected."
::= { snAgentBoot 1 }
snAgBootSeqEntry OBJECT-TYPE
SYNTAX SnAgBootSeqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the boot sequence table."
INDEX { snAgBootSeqIndex }
::= { snAgBootSeqTable 1 }
SnAgBootSeqEntry ::= SEQUENCE {
snAgBootSeqIndex
INTEGER,
snAgBootSeqInstruction
INTEGER,
snAgBootSeqIpAddr
IpAddress,
snAgBootSeqFilename
DisplayString,
snAgBootSeqRowStatus
INTEGER
}
snAgBootSeqIndex OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to the boot sequence table."
::= { snAgBootSeqEntry 1 }
snAgBootSeqInstruction OBJECT-TYPE
SYNTAX INTEGER {
fromPrimaryFlash(1),
fromSecondaryFlash(2),
fromTftpServer(3),
fromBootpServer(4),
fromPcmciaCard1(5),
fromPcmciaCard2(6) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The instruction for the boot code."
::= { snAgBootSeqEntry 2 }
snAgBootSeqIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ip address of the TFTP server if snAgBootSeqInstruction
was set to 'fromTftpServer'; otherwise, this object is not
used in any other boot instruction."
::= { snAgBootSeqEntry 3 }
snAgBootSeqFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The image filename on the TFTP server if snAgBootSeqInstruction
was set to 'fromTftpServer'; otherwise, this object is not
used in any other boot instruction."
::= { snAgBootSeqEntry 4 }
snAgBootSeqRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To create or delete a boot sequence table entry."
::= { snAgBootSeqEntry 5 }
-- SP Boot Sequence Table
snAgSpBootSeqTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgSpBootSeqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of image load sequnce instructions to the boot code for
the slave (line) modules. Boot code will start from instruction of
the first valid entry to load the image. If failed, it will use
the second valid entry and so on, until a succesful load has
completed. Each entry must have an unique instruction, duplicate
instructions will be rejected."
::= { snAgentBoot 2 }
snAgSpBootSeqEntry OBJECT-TYPE
SYNTAX SnAgSpBootSeqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the slave module boot sequence table."
INDEX { snAgSpBootSeqSpNumber, snAgSpBootSeqIndex }
::= { snAgSpBootSeqTable 1 }
SnAgSpBootSeqEntry ::= SEQUENCE {
snAgSpBootSeqSpNumber
INTEGER,
snAgSpBootSeqIndex
Integer32,
snAgSpBootSeqInstruction
INTEGER,
snAgSpBootSeqIpAddr
IpAddress,
snAgSpBootSeqFilename
DisplayString,
snAgSpBootSeqRowStatus
INTEGER
}
snAgSpBootSeqSpNumber OBJECT-TYPE
SYNTAX INTEGER (0..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The slot numner of a slave/witch processor module for which
this boot sequence applies. Setting value 0 applies to all SP
modules. Index 0 is valid only for setting to simplify the set
operation for all the modules."
::= { snAgSpBootSeqEntry 1 }
snAgSpBootSeqIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index to the boot sequence table."
::= { snAgSpBootSeqEntry 2 }
snAgSpBootSeqInstruction OBJECT-TYPE
SYNTAX INTEGER {
fromSpPrimaryFlash(1),
fromSpSecondaryFlash(2),
fromMpPrimaryFlash(3),
fromMpSecondaryFlash(4),
fromPcmciaCard1(5),
fromPcmciaCard2(6),
fromTftpServer(7),
interactively(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The instruction for the boot code."
::= { snAgSpBootSeqEntry 3 }
snAgSpBootSeqIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ip address of the TFTP server if snAgBootSeqInstruction
was set to 'fromTftpServer'; otherwise, this object is not
used in any other boot instruction."
::= { snAgSpBootSeqEntry 4 }
snAgSpBootSeqFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The image filename on the TFTP server if snAgBootSeqInstruction
was set to 'fromTftpServer'; otherwise, this object is not
used in any other boot instruction."
::= { snAgSpBootSeqEntry 5 }
snAgSpBootSeqRowStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
delete(2),
create(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To create or delete a boot sequence table entry."
::= { snAgSpBootSeqEntry 6 }
--- Encoded Octet Strings for the Configuration File Transfer
snAgCfgEosTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgCfgEosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table represents the fragmented Configuration File data packet
with checksum include in each rows of this table. A SNMP-SET
represents configuration file download, and a SNMP-GET represents
configuration file upload. This action is only if the SNMP-SET of
snAgCfgLoad command is sent along with this table consecutively. The
applicable snAgCfgLoad command value is as followings:
uploadFromFlashToNMS(23),
downloadToFlashFromNMS(24),
uploadFromDramToNMS(25),
downloadToDramFromNMS(26)."
::= { snAgCfgEos 1 }
snAgCfgEosEntry OBJECT-TYPE
SYNTAX SnAgCfgEosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An EOS row in the table of encoded octet strings for table
snAgCfgEosTable. "
INDEX { snAgCfgEosIndex }
::= { snAgCfgEosTable 1 }
SnAgCfgEosEntry ::=
SEQUENCE {
snAgCfgEosIndex
Integer32,
snAgCfgEosPacket
OCTET STRING,
snAgCfgEosChkSum
Integer32
}
snAgCfgEosIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Each VLAN EOS Buffer Identifier have a multiple
VLAN table entries."
::= { snAgCfgEosEntry 1 }
snAgCfgEosPacket OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..1000))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An encoded octet string. On reads it contains an integral
number of configuration file data packets. The size
of each encoded octet string is less than or equal to 1400
bytes."
::= { snAgCfgEosEntry 2 }
snAgCfgEosChkSum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A checksum of each configuration file data packet."
::= { snAgCfgEosEntry 3 }
-- Stackable Management Group
snStackGen OBJECT IDENTIFIER ::= { snStack 1 }
snStackSecSwitchInfo OBJECT IDENTIFIER ::= { snStack 2 }
-- MIB Objects
-- General Stackable Management Information
snStackPriSwitchMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Stackable Management Primary Switch mode
either enabled or disabled and the default is
disabled mode.
enabled(1)...........primary switch enabled
disabled(0)..........primary switch disabled"
::= { snStackGen 1 }
snStackMaxSecSwitch OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Maximum Secondary Switches are allowed in the
Stackable Management Group."
::= { snStackGen 2 }
snStackTotalSecSwitch OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Total Secondary Switches currently connected to the
Stackable Management Group."
::= { snStackGen 3 }
snStackSyncAllSecSwitch OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
invalid(1),
device(2),
global(3),
local(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Synchronize all the secondary switches in the
Stackable Management Group with the following commands.
device(2)...........device related parameters.
global(3)...........global parameters.
local(4)............local parameters.
The return result of the above commands are either
normal(0)...........normal condition.
invalid(1)...........invalid result."
::= { snStackGen 4 }
snStackSmSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Slot 0 is the Master slot and Slot 1-8 are slaves.
All the slot-based MIB data can be retrieved with respect to
this slot index such as snChassis global MIB. "
::= { snStackGen 5 }
snStackFmpSetProcess OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
pending(1),
failure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"normal(0) - The set process is either in an idle state or FMP-SET-SUCCESS state.
pending(1) - The pending process is waiting for the result of an FMP-SET.
failure(2) - The failure result of an FMP-SET."
::= { snStackGen 6 }
-- Stackable Management Secondary Switch Information Table
snStackSecSwitchTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnStackSecSwitchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"If snSwGroupOperMode is configured as basic mode
which is VLAN by Port, Layer2 switching,
then this table is valid. Each VLAN switch port
could have a number of VLAN IDs."
::= { snStackSecSwitchInfo 1 }
snStackSecSwitchEntry OBJECT-TYPE
SYNTAX SnStackSecSwitchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Stackable Management Secondary Switch
Information table."
INDEX {
snStackSecSwitchIndex
}
::= { snStackSecSwitchTable 1 }
SnStackSecSwitchEntry ::= SEQUENCE {
snStackSecSwitchIndex
INTEGER,
snStackSecSwitchSlotId
INTEGER,
snStackSecSwitchPortCnts
INTEGER,
snStackSecSwitchEnabled
INTEGER,
snStackSecSwitchAck
INTEGER,
snStackSecSwitchMacAddr
MacAddress,
snStackSecSwitchSyncCmd
INTEGER,
snStackSecSwitchIpAddr
IpAddress,
snStackSecSwitchSubnetMask
IpAddress,
snStackSecSwitchCfgCmd
INTEGER
}
snStackSecSwitchIndex OBJECT-TYPE
SYNTAX INTEGER (1..26)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The secondary switch index must not be greater than the snStackMaxSecSwitch."
::= { snStackSecSwitchEntry 1 }
snStackSecSwitchSlotId OBJECT-TYPE
SYNTAX INTEGER (1..26)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The secondary switch slot ID must be set before the Configuration
command sent from the primary switch to the secondary switch
either manually or automatically - snStackSecSwitchCfgCmd."
::= { snStackSecSwitchEntry 2 }
snStackSecSwitchPortCnts OBJECT-TYPE
SYNTAX INTEGER (1..26)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ports in this secondary switch."
::= { snStackSecSwitchEntry 3 }
snStackSecSwitchEnabled OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The secondary switch has been selected to Stackable Management Group."
::= { snStackSecSwitchEntry 4 }
snStackSecSwitchAck OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The secondary switch has sent reponse to the primary switch."
::= { snStackSecSwitchEntry 5 }
snStackSecSwitchMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The secondary switch physical address. The physical address
represents a MAC Station."
::= { snStackSecSwitchEntry 6 }
snStackSecSwitchSyncCmd OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
invalid(1),
device(2),
global(3),
local(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Synchronize the secondary switches in the
Stackable Management Group with the following commands.
device(2)...........device related parameters.
global(3)...........global parameters.
local(4)............local parameters.
The return result of the above commands are either
normal(0)...........normal condition.
invalid(1)...........invalid result."
::= { snStackSecSwitchEntry 7 }
snStackSecSwitchIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The secondary switch IP Address and is used for
manual-command of snStackSecSwitchCfgCmd."
::= { snStackSecSwitchEntry 8 }
snStackSecSwitchSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The secondary switch IP Subnet Mask and is used for
manual-command of snStackSecSwitchCfgCmd."
::= { snStackSecSwitchEntry 9 }
snStackSecSwitchCfgCmd OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
invalid(1),
auto(2),
manual(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"snStackSecSwitchSlotId must be set before the Configuration
command sent from the primary switch to the secondary switch
either manually or automatically.
auto(2)...........auto-configuration command sent.
manual(3).........manual-configuration command sent.
if manual-mode is used, snStackSecSwitchIpAddr
and snStackSecSwitchSubnetMask must be
first set before this command is sent.
The return result of the above commands are either
normal(0)...........normal condition.
invalid(1)..........invalid result."
::= { snStackSecSwitchEntry 10 }
-- System Logging Group
snAgSysLogGbl OBJECT IDENTIFIER ::= { snAgentLog 1 }
snAgSysLogGblEnable OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable system logging."
DEFVAL { enabled }
::= { snAgSysLogGbl 1 }
snAgSysLogGblBufferSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of dynamic system logging entries."
DEFVAL { 50 }
::= { snAgSysLogGbl 2 }
snAgSysLogGblClear OBJECT-TYPE
SYNTAX INTEGER { normal(0), clearAll(1), clearDynamic(2), clearStatic(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear dynamic and/or static system logging buffers."
::= { snAgSysLogGbl 3 }
snAgSysLogGblCriticalLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Filter events going to the logging buffer. This is a packed
bit string object of which each bit has the following meaning:
(bit 0 is the least significant bit).
bit position meaning
------------ -------
8-31 reserved
7 Warning (warning conditions)
6 Notification (normal but significant conditions)
5 Informational (informational messages)
4 Error (error conditions)
3 Emergency (system is unusable)
2 Debugging (debugging messages)
1 Critical (critical conditions)
0 Alert (immediate action needed)
Setting a critical level bit to 1 makes the logging buffer
accept the corresponding event. Resetting a critical level
bit to 0 makes the logging buffer reject the corresponding
event."
DEFVAL { 255 }
::= { snAgSysLogGbl 4 }
snAgSysLogGblLoggedCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number events logged in the system logging buffer."
::= { snAgSysLogGbl 5 }
snAgSysLogGblDroppedCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of events dropped."
::= { snAgSysLogGbl 6 }
snAgSysLogGblFlushedCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that the system logging buffer was cleared."
::= { snAgSysLogGbl 7 }
snAgSysLogGblOverrunCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that the system logging buffer was wrapped
around."
::= { snAgSysLogGbl 8 }
snAgSysLogGblServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"IP address of syslog server."
::= { snAgSysLogGbl 9 }
snAgSysLogGblFacility OBJECT-TYPE
SYNTAX INTEGER {
kern(1),
user(2),
mail(3),
daemon(4),
auth(5),
syslog(6),
lpr(7),
news(8),
uucp(9),
sys9(10),
sys10(11),
sys11(12),
sys12(13),
sys13(14),
sys14(15),
cron(16),
local0(17),
local1(18),
local2(19),
local3(20),
local4(21),
local5(22),
local6(23),
local7(24)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Facility code."
DEFVAL { user }
::= { snAgSysLogGbl 10 }
snAgSysLogGblPersistenceEnable OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable system logging persistence."
DEFVAL { enabled }
::= { snAgSysLogGbl 11 }
-- Dynamic System Logging Buffer Table
snAgSysLogBufferTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgSysLogBufferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Dynamic system logging buffer table."
::= { snAgentLog 2 }
snAgSysLogBufferEntry OBJECT-TYPE
SYNTAX SnAgSysLogBufferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the dynamic system logging buffer table."
INDEX { snAgSysLogBufferIndex }
::= { snAgSysLogBufferTable 1 }
SnAgSysLogBufferEntry ::= SEQUENCE {
snAgSysLogBufferIndex
Integer32,
snAgSysLogBufferTimeStamp
TimeTicks,
snAgSysLogBufferCriticalLevel
INTEGER,
snAgSysLogBufferMessage
DisplayString,
snAgSysLogBufferCalTimeStamp
DisplayString
}
snAgSysLogBufferIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to the dynamic system logging buffer table."
::= { snAgSysLogBufferEntry 1 }
snAgSysLogBufferTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A time stamp when the event is logged."
::= { snAgSysLogBufferEntry 2 }
snAgSysLogBufferCriticalLevel OBJECT-TYPE
SYNTAX INTEGER {
other(1),
alert(2),
critical(3),
debugging(4),
emergency(5),
error(6),
informational(7),
notification(8),
warning(9) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The critical level of this event."
::= { snAgSysLogBufferEntry 3 }
snAgSysLogBufferMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system logging message."
::= { snAgSysLogBufferEntry 4 }
snAgSysLogBufferCalTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A time stamp when the event is logged. This object returns
a NULL terminated time stamp string if the system calendar
time was set. It returns a zero length string if the system
calendar time was not set."
::= { snAgSysLogBufferEntry 5 }
-- Static System Logging Buffer Table
snAgStaticSysLogBufferTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgStaticSysLogBufferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Static system logging buffer table."
::= { snAgentLog 3 }
snAgStaticSysLogBufferEntry OBJECT-TYPE
SYNTAX SnAgStaticSysLogBufferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the static system logging buffer table."
INDEX { snAgStaticSysLogBufferIndex }
::= { snAgStaticSysLogBufferTable 1 }
SnAgStaticSysLogBufferEntry ::= SEQUENCE {
snAgStaticSysLogBufferIndex
INTEGER,
snAgStaticSysLogBufferTimeStamp
TimeTicks,
snAgStaticSysLogBufferCriticalLevel
INTEGER,
snAgStaticSysLogBufferMessage
DisplayString,
snAgStaticSysLogBufferCalTimeStamp
DisplayString
}
snAgStaticSysLogBufferIndex OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to the static system logging buffer table."
::= { snAgStaticSysLogBufferEntry 1 }
snAgStaticSysLogBufferTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A time stamp when the event is logged."
::= { snAgStaticSysLogBufferEntry 2 }
snAgStaticSysLogBufferCriticalLevel OBJECT-TYPE
SYNTAX INTEGER {
other(1),
alert(2),
critical(3),
debugging(4),
emergency(5),
error(6),
informational(7),
notification(8),
warning(9) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The critical level of this event."
::= { snAgStaticSysLogBufferEntry 3 }
snAgStaticSysLogBufferMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system logging message."
::= { snAgStaticSysLogBufferEntry 4 }
snAgStaticSysLogBufferCalTimeStamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A time stamp when the event is logged. This object returns
a NULL terminated time stamp string if the system calendar
time was set. It returns a zero length string if the system
calendar time was not set."
::= { snAgStaticSysLogBufferEntry 5 }
-- SysLog Server Table
snAgSysLogServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgSysLogServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"System Log Server table."
::= { snAgentLog 4 }
snAgSysLogServerEntry OBJECT-TYPE
SYNTAX SnAgSysLogServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the SysLog Server table."
INDEX {snAgSysLogServerIP, snAgSysLogServerUDPPort}
::= { snAgSysLogServerTable 1 }
SnAgSysLogServerEntry ::= SEQUENCE {
snAgSysLogServerIP
IpAddress,
snAgSysLogServerUDPPort
INTEGER,
snAgSysLogServerRowStatus
INTEGER
}
snAgSysLogServerIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP address of syslog server."
::= { snAgSysLogServerEntry 1 }
snAgSysLogServerUDPPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"UDP port number of syslog server."
::= { snAgSysLogServerEntry 2 }
snAgSysLogServerRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to create and
delete row in the table and control
if they are used. The values
that can be written are:
delete(3)...deletes the row
create(4)...creates a new row
If the row exists, then a SET with
value of create(4) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
other(1)....some other case
valid(2)....the row exists and is valid"
::= { snAgSysLogServerEntry 3 }
-- Agent System Parameters Configuration Table
snAgentSysParaConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentSysParaConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Agent of each board."
::= { snAgentSysParaConfig 1 }
snAgentSysParaConfigEntry OBJECT-TYPE
SYNTAX SnAgentSysParaConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the Agent System Parameters Configuation table."
INDEX { snAgentSysParaConfigIndex }
::= { snAgentSysParaConfigTable 1 }
SnAgentSysParaConfigEntry ::= SEQUENCE {
snAgentSysParaConfigIndex
Integer32,
snAgentSysParaConfigDescription
DisplayString,
snAgentSysParaConfigMin
Integer32,
snAgentSysParaConfigMax
Integer32,
snAgentSysParaConfigDefault
Integer32,
snAgentSysParaConfigCurrent
Integer32
}
snAgentSysParaConfigIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to the Agent System Parameters Configuation Table."
::= { snAgentSysParaConfigEntry 1 }
snAgentSysParaConfigDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main board description string."
::= { snAgentSysParaConfigEntry 2 }
snAgentSysParaConfigMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum value of this Agent System Parameter."
::= { snAgentSysParaConfigEntry 3 }
snAgentSysParaConfigMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum value of this Agent System Parameter."
::= { snAgentSysParaConfigEntry 4 }
snAgentSysParaConfigDefault OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The default value of this Agent System Parameter."
::= { snAgentSysParaConfigEntry 5 }
snAgentSysParaConfigCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current configurated value of this Agent System Parameter."
::= { snAgentSysParaConfigEntry 6 }
-- Agent Configured Module Table
snAgentConfigModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentConfigModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of each configured module information."
::= { snAgentConfigModule 1 }
snAgentConfigModuleEntry OBJECT-TYPE
SYNTAX SnAgentConfigModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the Agent Configured Module table."
INDEX { snAgentConfigModuleIndex }
::= { snAgentConfigModuleTable 1 }
SnAgentConfigModuleEntry ::= SEQUENCE {
snAgentConfigModuleIndex
Integer32,
snAgentConfigModuleType
INTEGER,
snAgentConfigModuleRowStatus
INTEGER,
snAgentConfigModuleDescription
DisplayString,
snAgentConfigModuleOperStatus
DisplayString,
snAgentConfigModuleSerialNumber
DisplayString,
snAgentConfigModuleNumberOfPorts
Integer32,
snAgentConfigModuleMgmtModuleType
INTEGER,
snAgentConfigModuleNumberOfCpus
Integer32
}
snAgentConfigModuleIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to the Agent Configured Module Table."
::= { snAgentConfigModuleEntry 1 }
snAgentConfigModuleType OBJECT-TYPE
SYNTAX INTEGER {
bi8PortGigManagementModule(0),
bi4PortGigManagementModule(1),
bi16PortCopperManagementModule(2),
bi4PortGigModule(3),
fi2PortGigManagementModule(4),
fi4PortGigManagementModule(5),
bi8PortGigCopperManagementModule(6),
fi8PortGigManagementModule(7),
bi8PortGigModule(8),
bi12PortGigCopper2PortGigFiberManagement(9),
bi24PortCopperModule(10),
fi24PortCopperModule(11),
bi16Port100FXModule(12),
bi8Port100FXModule(13),
bi8PortGigCopperModule(14),
bi12PortGigCopper2PortGigFiber(15),
bi2PortGigManagementModule(18),
bi24Port100FXModule(19),
bi0PortManagementModule(20),
pos622MbsModule(21),
pos155MbsModule(22),
bi2PortGigModule(23),
bi2PortGigCopperModule(24),
fi2PortGigModule(25),
fi4PortGigModule(26),
fi8PortGigModule(27),
fi8PortGigCopperModule(28),
fi8PortGigCopperManagementModule(29),
pos155Mbs2PModule(30),
fi4PortGigCopperManagementModule(31),
fi2PortGigCopperManagementModule(32),
bi4PortGigCopperManagementModule(33),
bi2PortGigCopperManagementModule(34),
bi8PortGigM4ManagementModule(35),
bi4PortGigM4ManagementModule(36),
bi2PortGigM4ManagementModule(37),
bi0PortGigM4ManagementModule(38),
bi0PortWSMManagementModule(39),
biPos2Port2488MbsModule(40),
bi0PortWSMModule(41),
niPos2Port2488MbsModule(42),
ni4802(43),
bi4PortGigNPAModule(44),
biAtm2Port155MbsModule(45),
biAtm4Port155MbsModule(46),
bi1Port10GigModule(47),
fes4802Module(48),
fes2402Module(49),
fes9604Module(50),
fes12GigCopperAndGigFiberModule(51),
fesx24GigModule(52),
fesx24Gig2TenGigModule(53),
fesx24Gig1TenGigModule(54),
fesx48GigModule(55),
fesx48Gig2TenGigModule(56),
fesx48Gig1TenGigModule(57),
bi40PortGigCopperHVModule(58), --unused
bi60PortGigCopperHVModule(59), --unused
bi8Port10GigModule(60), --unused
bi10PortGigHVModule(61), --unused
bi20PortGigHVModule(62), --unused
bi24PortGigModule(63), --unused
bi24PortGigCopperModule(64), --unused
bi48PortGigCopperModule(65), --unused
bi24PortGigFiberModule(66), --unused
ni4Port10GigSPModule(75), --unused
ni40PortGigSPModule(76), --unused
ni40PortGigCopperSPModule(77), --unused
ni2Port10GigSPModule(78), --unused
ni10PortGigSPModule(79), --unused
ni20PortGigSPModule(80), --unused
xmr4Port10GigSPModule(81), --unused
xmr20PortGigSPModule(82), --unused
xmr2Port10GigSPModule(83), --unused
xmr20PortGigCopperSPModule(84), --unused
xmr20PortGigFXSPModule(85), --unused
niImrMrManagementModule(86), --unused
niXmrMrManagementModule(87), --unused
xer4Port10GigSPModule(88), --unused
xer2Port10GigSPModule(89), --unused
xer20PortGigCopperSPModule(90), --unused
xer20PortGigFXSPModule(91), --unused
mlx4Port10GigSPModule(92), --unused
mlx2Port10GigSPModule(93), --unused
mlx20PortGigCopperSPModule(94), --unused
mlx20PortGigFXSPModule(95), --unused
mlx48PortGigMrj21SPModule(103), --unused
fesx24GigFiberGigCopperModule(112),
fesx24GigFiber2TenGigModule(113),
fesx24GigFiber1TenGigModule(114),
-- Modules for FGS/FLS family
fgs24PortManagementModule(144),
fgs48PortManagementModule(145),
fgsXfp2Port10gModule(152),
fgsCx42Port10gModule(153),
fgsXfp1Cx41Port10gModule(154),
fgsXpf1Port10gModule(155),
fls24PortCopperBaseModule(160),
fls48PortCopperBaseModule(161),
flsXfp1Port10gModule(168),
flsCx41Port10gModule(169),
--Modules for FCX family
fcx624SBaseModule(176),
fcx648SBaseModule(177),
fcx624SPoeBaseModule(180),
fcx648SPoeBaseModule(181),
fcxXfp2Port10gModule(184),
fcxCx42Port16gModule(185),
fcx624SFBaseModule(192),
biFiJc48ePort100fxIpcModule(195),
biFiJc48tPort100fxIpcModule(196),
biFiJc8PortGigM4ManagementModule(197),
biFiJc8PortGigIgcModule(198),
biFiJc16PortGigIgcModule(200),
biJc24PortCopperIpc4GigIgcModule(201),
biJc16PortGigCopperIgcModule(202),
biFiJc24Port100fxIpcModule(206),
bi2Port10GigModule(207),
biJc48tPortRJ21OmpModule(208),
biJc48ePortRJ45OmpModule(209),
biJc24PortIpcRJ45PoeModule(212),
biJc2PortGigIgcM4ManagementModule(214),
--Modules for MG-8, RX, XMR, MLX
fdryBi4Port10GigModule(1048), --
fdryBi40PortGigModule(1049), --
fdryBi1Port100FXManagementModule(1050),
fdryBi2Port10GigModule(1051), --
fdryBi40PortGigCopperModule(1052), --
fdryBi60PortGigCopperModule(1053), --
fdryBi4Port10GigHVModule(1054), --
fdryBi2Port10GigHVModule(1055), --
fdryBi8Port10GigHVModule(1056), --
fdryBi40PortGigHVModule(1057), --
fdryBi40PortGigCopperHVModule(1058), --
fdryBi60PortGigCopperHVModule(1059), --
fdryBi8Port10GigModule(1060), --
fdryBi10PortGigHVModule(1061), --
fdryBi20PortGigHVModule(1062), --
fdryBi24PortGigModule(1063), --
fdryBi24PortGigCopperModule(1064), --
fdryBi48PortGigCopperModule(1065),
fdryBi24PortGigFiberModule(1066),
fdryBi16Port10GigModule(1067),
fdryNi4Port10GigSPModule(1075),
fdryNi40PortGigSPModule(1076),
fdryNi40PortGigCopperSPModule(1077),
fdryNi2Port10GigSPModule(1078),
fdryNi10PortGigSPModule(1079),
fdryNi20PortGigSPModule(1080),
fdryXmr4Port10GigSPModule(1081), --
fdryXmr20PortGigSPModule(1082), --
fdryXmr2Port10GigSPModule(1083), --
fdryXmr20PortGigCopperSPModule(1084), --
fdryXmr20PortGigFXSPModule(1085), --
fdryNiImrMrManagementModule(1086),
fdryNiXmrMrManagementModule(1087),
fdryMlx4Port10GigSPModule(1088), --
fdryMlx2Port10GigSPModule(1089), --
fdryMlx20PortGigCopperSPModule(1090), --
fdryMlx20PortGigFXSPModule(1091), --
brMlx4Port10GigXModule(1093),
brMlx24PortGigCopperXModule(1094),
brMlx24PortGigSfpXModule(1095),
niCes24PortFiberModule(1096),
niCes24PortCopperModule(1097),
niCes2Port10GigModule(1098),
niCes48PortFiberModule(1099),
niCes48PortCopperModule(1100),
niCes48PortFiberWith2Port10GModule(1101),
niCes48PortCopperWith2Port10GModule(1102),
fdryMlx48PortGigMrj21SPModule(1103), --
fdryXmr2PortOC192SPModule(1104), --
fdryXmr1PortOC192SPModule(1105), --
fdryXmr8PortOC48SPModule(1106), --
fdryXmr4PortOC48SPModule(1107), --
fdryXmr2PortOC48SPModule(1108), --
fdryNiMlxMrManagementModule(1109),--
niMlx8Port10GigMModule (1110),
niMlx8Port10GigDModule (1111),
brMlx8Port10GigXModule (1112),
brMlx2Port100GigXModule (1113),
brcdMlxMr2ManagementModule(1114), -- for (BR-MLX-MR2-M board)
brcdXmrMr2ManagementModule(1115), -- for (BR-MLX-MR2-X board)
brcdMlx32Mr2ManagementModule(1116), -- for (BR-MLX32-MR2-M board)
brcdXmr32Mr2ManagementModule(1117), -- for (BR-MLX32-MR2-X board)
brcdNiXmr32MrManagementModule(1118),
brcdNiMlx32MrManagementModule(1119),
--Modules for FastIron Superx, SXR8, SXR16, V4 and V6 Modules
fdryFiV4Sx12ComboPortManagementModule(2064),
fdryFiV4Sx2Port10gModule(2065),
fdryFiV4Sx24PortGigCopperModule(2066),
fdryFiV4Sx24PortGigFiberModule(2067),
fdryFiV4Sx2Port10gLanWanModule(2068),
fdryFiV4Sx24Port100m1gFiberModule(2069),
fdryFiV4Sx12ComboPortManagement2Module(2074),
fdryFiV4Sx210gPortManagementModule(2080),
fdryFiSx0PortManagementModule(2081),
fdryFiV4Sx4g4fPortManagementModule(2083),
fdryFiV6Sx12ComboPortManagementModule(2096),
fdryFiV6Sx24PortGigCopperModule(2098),
fdryFiV6Sx2Port10gModule(2100),
fdryFiV6Sx24Port100m1gFiberModule(2101),
fdryFiV6Sx210gPortManagementModule(2102),
fdryFiV6Sx48PortGigCopperPoeModule(2103),
fdryFiV6Sx4g4fPortManagementModule(2104),
fdryFiV6Sx12ComboPortManagement2Module(2105),
fdryFiV6Sx48PortGigCopperModule(2106),
-- Modules for FWS family
fdryFws24PortCopperBaseModule(2224),
fdryFws48PortCopperBaseModule(2225),
fdryFws24GPortCopperBaseModule(2226),
fdryFws48GPortCopperBaseModule(2227),
--Modules for FCX family
fdryFcx624BaseModule(2208),
fdryFcx648BaseModule(2209),
fdryFcxSfpPlus4Port10gModule(2220),
--Modules for ICX6610 family
fdryIcx6610624BaseModule(2240),
fdryIcx6610648BaseModule(2241),
fdryIcx6610624PoeBaseModule(2244),
fdryIcx6610648PoeBaseModule(2245),
fdryIcx6610624FBaseModule(2246),
fdryIcx6610DualMode8PortModule(2248),
fdryIcx6610Qsfp10Port160gModule(2249),
--Modules for ICX6430 family
fdryIcx6430624BaseModule(2016),
fdryIcx6430648BaseModule(2017),
fdryIcx6430624PoeBaseModule(2020),
fdryIcx6430648PoeBaseModule(2021),
fdryIcx6430sfp4Port4gModule(2024),
--Modules for ICX6450 family
fdryIcx6450624BaseModule(2032),
fdryIcx6450648BaseModule(2033),
fdryIcx6450624PoeBaseModule(2036),
fdryIcx6450648PoeBaseModule(2037),
fdryIcx6450sfp4Port40gModule(2040)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Configured Module Type."
::= { snAgentConfigModuleEntry 2 }
snAgentConfigModuleRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To create or delete a configured module table entry."
::= { snAgentConfigModuleEntry 3 }
snAgentConfigModuleDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the configured module."
::= { snAgentConfigModuleEntry 4 }
snAgentConfigModuleOperStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module operational status. Zero length string indicates
that physical module has not been inserted to the chassis."
::= { snAgentConfigModuleEntry 5 }
snAgentConfigModuleSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module serial number. Zero length string indicates that
module serial number EEPROM has not been programmed or
the module does not support serial number EEPROM."
::= { snAgentConfigModuleEntry 6 }
snAgentConfigModuleNumberOfPorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ports of module."
::= { snAgentConfigModuleEntry 7 }
snAgentConfigModuleMgmtModuleType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
nonManagementModule(2),
unknownManagementModule(3),
m1ManagementModule(4),
m2ManagementModule(5),
m3ManagementModule(6),
m4ManagementModule(7),
m5ManagementModule(8),
jetcoreStackManagementModule(9),
muchoManagementModule(10),
rottWeilerManagementModule(11),
fesXStackManagementModule(12),
fgsStackManagementModule(13),
niCesManagementModule(14),
fastIronSuperXManagementModule(15),
fastIronSXRManagementModule(16),
fastIronV6SuperXManagementModule(17),
fastIronV6SXRManagementModule(18)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Management module type."
::= { snAgentConfigModuleEntry 8 }
snAgentConfigModuleNumberOfCpus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of module CPUs."
::= { snAgentConfigModuleEntry 9 }
-- Agent System Parameters stacking Configuration Table
snAgentConfigModule2Table OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentConfigModule2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of each configured stacking module information."
::= { snAgentConfigModule 2 }
snAgentConfigModule2Entry OBJECT-TYPE
SYNTAX SnAgentConfigModule2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the Agent Configured Stacking Module table."
INDEX { snAgentConfigModule2Unit,
snAgentConfigModule2Slot
}
::= { snAgentConfigModule2Table 1 }
SnAgentConfigModule2Entry ::= SEQUENCE {
snAgentConfigModule2Unit
Integer32,
snAgentConfigModule2Slot
Integer32,
snAgentConfigModule2Type
INTEGER,
snAgentConfigModule2RowStatus
INTEGER,
snAgentConfigModule2Description
DisplayString,
snAgentConfigModule2OperStatus
DisplayString,
snAgentConfigModule2SerialNumber
DisplayString,
snAgentConfigModule2NumberOfPorts
Integer32,
snAgentConfigModule2MgmtModuleType
INTEGER,
snAgentConfigModule2NumberOfCpus
Integer32
}
snAgentConfigModule2Unit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to the Agent Configured Module Table."
::= { snAgentConfigModule2Entry 1 }
snAgentConfigModule2Slot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index to the Agent Configured Module Table."
::= { snAgentConfigModule2Entry 2 }
snAgentConfigModule2Type OBJECT-TYPE
SYNTAX INTEGER {
bi8PortGigManagementModule(0),
bi4PortGigManagementModule(1),
bi16PortCopperManagementModule(2),
bi4PortGigModule(3),
fi2PortGigManagementModule(4),
fi4PortGigManagementModule(5),
bi8PortGigCopperManagementModule(6),
fi8PortGigManagementModule(7),
bi8PortGigModule(8),
bi12PortGigCopper2PortGigFiberManagement(9),
bi24PortCopperModule(10),
fi24PortCopperModule(11),
bi16Port100FXModule(12),
bi8Port100FXModule(13),
bi8PortGigCopperModule(14),
bi12PortGigCopper2PortGigFiber(15),
bi2PortGigManagementModule(18),
bi24Port100FXModule(19),
bi0PortManagementModule(20),
pos622MbsModule(21),
pos155MbsModule(22),
bi2PortGigModule(23),
bi2PortGigCopperModule(24),
fi2PortGigModule(25),
fi4PortGigModule(26),
fi8PortGigModule(27),
fi8PortGigCopperModule(28),
fi8PortGigCopperManagementModule(29),
pos155Mbs2PModule(30),
fi4PortGigCopperManagementModule(31),
fi2PortGigCopperManagementModule(32),
bi4PortGigCopperManagementModule(33),
bi2PortGigCopperManagementModule(34),
bi8PortGigM4ManagementModule(35),
bi4PortGigM4ManagementModule(36),
bi2PortGigM4ManagementModule(37),
bi0PortGigM4ManagementModule(38),
bi0PortWSMManagementModule(39),
biPos2Port2488MbsModule(40),
bi0PortWSMModule(41),
niPos2Port2488MbsModule(42),
ni4802(43),
bi4PortGigNPAModule(44),
biAtm2Port155MbsModule(45),
biAtm4Port155MbsModule(46),
bi1Port10GigModule(47),
fes4802Module(48),
fes2402Module(49),
fes9604Module(50),
fes12GigCopperAndGigFiberModule(51),
fesx24GigModule(52),
fesx24Gig2TenGigModule(53),
fesx24Gig1TenGigModule(54),
fesx48GigModule(55),
fesx48Gig2TenGigModule(56),
fesx48Gig1TenGigModule(57),
superx12ComboPortManagementModule(64),
superx2PortTenGigModule(65),
superx24PortGigCopperModule(66),
superx24PortGigFiberModule(67),
superx2PortTenGigLanWanModule(68),
superx24Port100tx1PortGigFiberModule(69),
superx12ComboPortManagement2Module(74),
superxR2PortTenGigManagementModule(80),
superxRManagementModule(81),
fesx24GigFiberGigCopperModule(112),
fesx24GigFiber2TenGigModule(113),
fesx24GigFiber1TenGigModule(114),
fgs24PortManagementModule(144),
fgs48PortManagementModule(145),
fgsXfp2Port10gModule(152),
fgsCx42Port10gModule(153),
fgsXfp1Cx41Port10gModule(154),
fgsXpf1Port10gModule(155),
fls24PortCopperBaseModule(160),
fls48PortCopperBaseModule(161),
flsXfp1Port10gModule(168),
flsCx41Port10gModule(169),
fcx624SBaseModule(176),
fcx648SBaseModule(177),
fcx624SPoeBaseModule(180),
fcx648SPoeBaseModule(181),
fcxXfp2Port10gModule(184),
fcxCx42Port16gModule(185),
fcx624SFBaseModule(192),
biFiJc48ePort100fxIpcModule(195),
biFiJc48tPort100fxIpcModule(196),
biFiJc8PortGigM4ManagementModule(197),
biFiJc8PortGigIgcModule(198),
biFiJc16PortGigIgcModule(200),
biJc24PortCopperIpc4GigIgcModule(201),
biJc16PortGigCopperIgcModule(202),
biFiJc24Port100fxIpcModule(206),
bi2Port10GigModule(207),
biJc48tPortRJ21OmpModule(208),
biJc48ePortRJ45OmpModule(209),
biJc24PortIpcRJ45PoeModule(212),
biJc2PortGigIgcM4ManagementModule(214),
-- Modules for FWS family
fdryFws24PortCopperBaseModule(2224),
fdryFws48PortCopperBaseModule(2225),
fdryFws24GPortCopperBaseModule(2226),
fdryFws48GPortCopperBaseModule(2227),
--Modules for FCX family
fdryFcx624BaseModule(2208),
fdryFcx648BaseModule(2209),
fdryFcxSfpPlus4Port10gModule(2220),
--Modules for ICX6610 family
fdryIcx6610624BaseModule(2240),
fdryIcx6610648BaseModule(2241),
fdryIcx6610624PoeBaseModule(2244),
fdryIcx6610648PoeBaseModule(2245),
fdryIcx6610624FBaseModule(2246),
fdryIcx6610DualMode8PortModule(2248),
fdryIcx6610Qsfp10Port160gModule(2249),
--Modules for ICX6430 family
fdryIcx6430624BaseModule(2016),
fdryIcx6430648BaseModule(2017),
fdryIcx6430624PoeBaseModule(2020),
fdryIcx6430648PoeBaseModule(2021),
fdryIcx6430sfp4Port4gModule(2024),
--Modules for ICX6450 family
fdryIcx6450624BaseModule(2032),
fdryIcx6450648BaseModule(2033),
fdryIcx6450624PoeBaseModule(2036),
fdryIcx6450648PoeBaseModule(2037),
fdryIcx6450sfp4Port40gModule(2040)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Configured Module Type."
::= { snAgentConfigModule2Entry 3 }
snAgentConfigModule2RowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To create or delete a configured module table entry."
::= { snAgentConfigModule2Entry 4 }
snAgentConfigModule2Description OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the configured module."
::= { snAgentConfigModule2Entry 5 }
snAgentConfigModule2OperStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module operational status. Zero length string indicates
that physical module has not been inserted to the chassis."
::= { snAgentConfigModule2Entry 6 }
snAgentConfigModule2SerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module serial number. Zero length string indicates that
module serial number EEPROM has not been programmed or
the module does not support serial number EEPROM."
::= { snAgentConfigModule2Entry 7 }
snAgentConfigModule2NumberOfPorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ports of module."
::= { snAgentConfigModule2Entry 8 }
snAgentConfigModule2MgmtModuleType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
nonManagementModule(2),
unknownManagementModule(3),
m1ManagementModule(4),
m2ManagementModule(5),
m3ManagementModule(6),
m4ManagementModule(7),
m5ManagementModule(8),
jetcoreStackManagementModule(9),
muchoManagementModule(10),
rottWeilerManagementModule(11),
fesXStackManagementModule(12),
fgsStackManagementModule(13) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Management module type."
::= { snAgentConfigModule2Entry 9 }
snAgentConfigModule2NumberOfCpus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of module CPUs."
::= { snAgentConfigModule2Entry 10 }
-- Agent User Access Group
snAgentUserGbl OBJECT IDENTIFIER ::= { snAgentUser 1 }
snAgentUserMaxAccnt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of user account entries can be configured."
::= { snAgentUserGbl 1 }
-- Agent User Account Table
snAgentUserAccntTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentUserAccntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of user account information."
::= { snAgentUser 2 }
snAgentUserAccntEntry OBJECT-TYPE
SYNTAX SnAgentUserAccntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the Agent User table."
INDEX { snAgentUserAccntName }
::= { snAgentUserAccntTable 1 }
SnAgentUserAccntEntry ::= SEQUENCE {
snAgentUserAccntName
DisplayString,
snAgentUserAccntPassword
DisplayString,
snAgentUserAccntEncryptCode
Integer32,
snAgentUserAccntPrivilege
Integer32,
snAgentUserAccntRowStatus
INTEGER
}
snAgentUserAccntName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user name."
::= { snAgentUserAccntEntry 1 }
snAgentUserAccntPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The user password."
::= { snAgentUserAccntEntry 2 }
snAgentUserAccntEncryptCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The password encryption method code."
::= { snAgentUserAccntEntry 3 }
snAgentUserAccntPrivilege OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The user privilege."
::= { snAgentUserAccntEntry 4 }
snAgentUserAccntRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4),
modify(5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To create or delete a user account table entry."
::= { snAgentUserAccntEntry 5 }
-- Agent Redundant Group
snAgentRedunGbl OBJECT IDENTIFIER ::= { snAgentRedundant 1 }
snAgentRedunActiveMgmtMod OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Slot number of the active management module. Setting
this object does not take effect immediately. Saving
configuration data to flash storage and reboot the
system are required to take effect. Setting a value of 0
requests the system to auto-select an active management
module after power up."
DEFVAL { 0 }
::= { snAgentRedunGbl 1 }
snAgentRedunSyncConfig OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency of the backup management module copying the
configuration data from the active management module.
Each unit is 1 second. Setting a value 0 will disable
the synchronization copy. Setting a negative value will
initiate the synchronization copy once immediately."
::= { snAgentRedunGbl 2 }
snAgentRedunBkupCopyBootCode OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If enabled(1), the backup management module copies the boot code
from the active management module to its boot code flash storage
after power up, and whenever the active management module's boot
code is updated. The backup management module does not copy if
both boot codes were identical."
DEFVAL { disabled }
::= { snAgentRedunGbl 3 }
snAgentEnableMgmtModRedunStateChangeTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the SNMP agent process is permitted to
generate management module redundancy state change traps."
DEFVAL { enabled }
::= { snAgentRedunGbl 4 }
snAgentRedunBkupBootLoad OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
operationError(17),
downloadBackup(20)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action object to down load a new boot code from boot flash storage
of the active management module to the backup management module.
The following are returned values from get operation:
normal(1)............no operation
operationError(17)...error codes
The following are input values from set operation:
downloadBackup(20)...download the boot code from the active
management module to the backup management
module
Any set operation is rejected during loading until error
or normal state is reached."
::= { snAgentRedunGbl 5 }
snAgentRedunSwitchOver OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To force a switch-over from standby to active state
if the backup management module exists in a chassis."
::= { snAgentRedunGbl 6 }
-- System CPU Utilization Table.
snAgentCpuUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentCpuUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to list utilization for all CPUs in the device."
::= { snAgentCpu 1 }
snAgentCpuUtilEntry OBJECT-TYPE
SYNTAX SnAgentCpuUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the CPU utilization table."
INDEX {
snAgentCpuUtilSlotNum,
snAgentCpuUtilCpuId,
snAgentCpuUtilInterval
}
::= { snAgentCpuUtilTable 1 }
SnAgentCpuUtilEntry ::= SEQUENCE {
snAgentCpuUtilSlotNum
Integer32,
snAgentCpuUtilCpuId
Integer32,
snAgentCpuUtilInterval
Integer32,
snAgentCpuUtilValue
Gauge32,
snAgentCpuUtilPercent
Gauge32,
snAgentCpuUtil100thPercent
Gauge32
}
snAgentCpuUtilSlotNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot number of module which contains the cpu."
::= { snAgentCpuUtilEntry 1 }
snAgentCpuUtilCpuId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The id of cpu. For non-VM1/WSM management module, there is one CPU.
For VM1/WSM there's one management CPU and three slave CPUs.
The management CPU could be turned off. For POS and ATM
there's no management CPU but two slave CPUs.
Id for management cpu is 1. Value of 2 or greater are for slave CPUs. "
::= { snAgentCpuUtilEntry 2 }
snAgentCpuUtilInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value, in seconds, for this utilization. For both management and slave CPU, we display
utilization for 1 sec, 5 sec, 60 sec and 300 sec interval."
::= { snAgentCpuUtilEntry 3 }
snAgentCpuUtilValue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The statistical CPU utilization in units of one-hundredth
of a percent. This value is deprecated. Users are recommended
to use snAgentCpuUtilPercent or snAgentCpuUtil100thPercent
instead."
::= { snAgentCpuUtilEntry 4 }
snAgentCpuUtilPercent OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statistical CPU utilization in units of a percent."
::= { snAgentCpuUtilEntry 5 }
snAgentCpuUtil100thPercent OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statistical CPU utilization in units of one-hundredth
of a percent."
::= { snAgentCpuUtilEntry 6 }
-- System Process Utilization Table.
snCpuProcessTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnCpuProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to list utilization and runtime for all CPU processes in the device."
::= { snAgentCpu 2 }
snCpuProcessEntry OBJECT-TYPE
SYNTAX SnCpuProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the CPU process table."
INDEX {
snCpuProcessName
}
::= { snCpuProcessTable 1 }
SnCpuProcessEntry ::= SEQUENCE {
snCpuProcessName
DisplayString,
snCpuProcess5SecUtil
Gauge32,
snCpuProcess1MinUtil
Gauge32,
snCpuProcess5MinUtil
Gauge32,
snCpuProcess15MinUtil
Gauge32,
snCpuProcessRuntime
Counter32
}
snCpuProcessName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The process name."
::= { snCpuProcessEntry 1 }
snCpuProcess5SecUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statistics collection of last 5 second process utilization."
::= { snCpuProcessEntry 2 }
snCpuProcess1MinUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statistics collection of last 1 minute process utilization."
::= { snCpuProcessEntry 3 }
snCpuProcess5MinUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statistics collection of last 5 minute process utilization."
::= { snCpuProcessEntry 4 }
snCpuProcess15MinUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statistics collection of last 15 minute process utilization."
::= { snCpuProcessEntry 5 }
snCpuProcessRuntime OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Process runtime in milliseconds."
::= { snCpuProcessEntry 6 }
-- Hardware ICBM (Integrated Central Buffer Manager) Counter Table.
snAgentHwICBMCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentHwICBMCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to list the ICBM counter values.
This table is not supported on 10G module."
::= { snAgentHw 1 }
snAgentHwICBMCounterEntry OBJECT-TYPE
SYNTAX SnAgentHwICBMCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row representing ICBM counter values for that slot."
INDEX {
snAgentHwICBMCounterSlot,
snAgentHwICBMCounterDMA
}
::= { snAgentHwICBMCounterTable 1 }
SnAgentHwICBMCounterEntry ::= SEQUENCE {
snAgentHwICBMCounterSlot
Unsigned32,
snAgentHwICBMCounterDMA
Unsigned32,
snAgentHwICBMCounterFreeDepth
Gauge32,
snAgentHwICBMCounterWriteDrop
Counter32,
snAgentHwICBMCounterWriteInput
Counter32,
snAgentHwICBMCounterWriteOutput
Counter32,
snAgentHwICBMCounterReadInput
Counter32,
snAgentHwICBMCounterReadOutput
Counter32
}
snAgentHwICBMCounterSlot OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number where ICBM resides."
::= { snAgentHwICBMCounterEntry 1 }
snAgentHwICBMCounterDMA OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DMA Id within a slot where ICBM resides. Valid only for Jetcore modules.
For non-Jetcore modules, this index is ignored by the agent. In this case, value
0 will be returned by the agent."
::= { snAgentHwICBMCounterEntry 2 }
snAgentHwICBMCounterFreeDepth OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current depth of the free queue for this ICBM."
::= { snAgentHwICBMCounterEntry 3 }
snAgentHwICBMCounterWriteDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Write sequencer drop count for this ICBM."
::= { snAgentHwICBMCounterEntry 4 }
snAgentHwICBMCounterWriteInput OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Write sequencer input counter for this ICBM."
::= { snAgentHwICBMCounterEntry 5 }
snAgentHwICBMCounterWriteOutput OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Write sequencer output counter for this ICBM."
::= { snAgentHwICBMCounterEntry 6 }
snAgentHwICBMCounterReadInput OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Read sequencer input counter for this ICBM."
::= { snAgentHwICBMCounterEntry 7 }
snAgentHwICBMCounterReadOutput OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Read sequencer output counter for this ICBM."
::= { snAgentHwICBMCounterEntry 8 }
-- IP CAM Statistics Table.
snCAMIpStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnCAMIpStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to list the IP CAM statistics.
"
::= { snAgentHw 2 }
snCAMIpStatEntry OBJECT-TYPE
SYNTAX SnCAMIpStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row representing IP CAM statistics for a given interface and level."
INDEX {
snCAMIpStatIfIndex,
snCAMIpStatLevel
}
::= { snCAMIpStatTable 1 }
SnCAMIpStatEntry ::= SEQUENCE {
snCAMIpStatIfIndex Unsigned32,
snCAMIpStatLevel Unsigned32,
snCAMIpStatFreeEntries Unsigned32,
snCAMIpStatTotalEntries Unsigned32
}
snCAMIpStatIfIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ifIndex value of the local interface."
::= { snCAMIpStatEntry 1 }
snCAMIpStatLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Level of CAM entry for that interface."
::= { snCAMIpStatEntry 2 }
snCAMIpStatFreeEntries OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Free entries in the IP CAM for that interface and level."
::= { snCAMIpStatEntry 3 }
snCAMIpStatTotalEntries OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total entries in the IP CAM for that interface and level."
::= { snCAMIpStatEntry 4 }
-- CAM Statistics Table.
snCAMStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnCAMStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to list the CAM statistics.
"
::= { snAgentHw 3 }
snCAMStatEntry OBJECT-TYPE
SYNTAX SnCAMStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row representing CAM statistics for a given DMA Id number."
INDEX {
snCamStatDMAIdNumber
}
::= { snCAMStatTable 1 }
SnCAMStatEntry ::= SEQUENCE {
snCamStatDMAIdNumber Unsigned32,
snCamStatDMAMasterNumber Unsigned32,
snCamStatFreePool0Entries Unsigned32,
snCamStatFreePool1Entries Unsigned32,
snCamStatFreePool2Entries Unsigned32,
snCamStatFreePool3Entries Unsigned32,
snCamStatFreeL2Entries Unsigned32,
snCamStatFreeL2LowestSection Unsigned32,
snCamStatHostLookupCount Counter32,
snCamStatRouteLookupCount Counter32,
snCamStatLevel1 Unsigned32,
snCamStatLevel2 Unsigned32,
snCamStatLevel3 Unsigned32,
snCamStatMacFailCount Counter32,
snCamStatIPRouteFailCount Counter32,
snCamStatIPSessionFailCount Counter32,
snCamStatIPMCastFailCount Counter32,
snCamStatL2SessionFailCount Counter32,
snCamStatAddMACCount Counter32,
snCamStatAddVLANCount Counter32,
snCamStatAddIPHostCount Counter32,
snCamStatAddIPRouteCount Counter32,
snCamStatAddIPSessionCount Counter32,
snCamStatAddIPMCastCount Counter32,
snCamStatAddL2SessionCount Counter32,
snCamStatAddIPXCount Counter32,
snCamStatDeleteDMACamCount Counter32
}
snCamStatDMAIdNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DMA Id number."
::= { snCAMStatEntry 1 }
snCamStatDMAMasterNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DMA Master for that DMA Id."
::= { snCAMStatEntry 2 }
snCamStatFreePool0Entries OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM free pool0 entries."
::= { snCAMStatEntry 3 }
snCamStatFreePool1Entries OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM free pool1 entries."
::= { snCAMStatEntry 4 }
snCamStatFreePool2Entries OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM free pool2 entries."
::= { snCAMStatEntry 5 }
snCamStatFreePool3Entries OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM free pool3 entries."
::= { snCAMStatEntry 6 }
snCamStatFreeL2Entries OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM Free L2 entries."
::= { snCAMStatEntry 7 }
snCamStatFreeL2LowestSection OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM Free L2 lowest section entries."
::= { snCAMStatEntry 8 }
snCamStatHostLookupCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM host lookup count for router."
::= { snCAMStatEntry 9 }
snCamStatRouteLookupCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM route lookup count for router."
::= { snCAMStatEntry 10 }
snCamStatLevel1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM stat level1 entries for router."
::= { snCAMStatEntry 11 }
snCamStatLevel2 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM stat level2 entries for router."
::= { snCAMStatEntry 12 }
snCamStatLevel3 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM stat level3 entries for router."
::= { snCAMStatEntry 13 }
snCamStatMacFailCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM MAC fail count."
::= { snCAMStatEntry 14 }
snCamStatIPRouteFailCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM IP route fail count."
::= { snCAMStatEntry 15 }
snCamStatIPSessionFailCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM IP session fail count."
::= { snCAMStatEntry 16 }
snCamStatIPMCastFailCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM IP multicast fail count."
::= { snCAMStatEntry 17 }
snCamStatL2SessionFailCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM L2 session fail count."
::= { snCAMStatEntry 18 }
snCamStatAddMACCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM add MAC count."
::= { snCAMStatEntry 19 }
snCamStatAddVLANCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM add VLAN count."
::= { snCAMStatEntry 20 }
snCamStatAddIPHostCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM add IP host count."
::= { snCAMStatEntry 21 }
snCamStatAddIPRouteCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM add IP route count."
::= { snCAMStatEntry 22 }
snCamStatAddIPSessionCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM add IP session count."
::= { snCAMStatEntry 23 }
snCamStatAddIPMCastCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM add IP multicast count."
::= { snCAMStatEntry 24 }
snCamStatAddL2SessionCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM add L2 session count."
::= { snCAMStatEntry 25 }
snCamStatAddIPXCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM add IPX count."
::= { snCAMStatEntry 26 }
snCamStatDeleteDMACamCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM delete DMA CAM count."
::= { snCAMStatEntry 27 }
-- System DRAM info Group.
snAgSystemDRAM OBJECT IDENTIFIER ::= { snAgentHw 4 }
snAgSystemDRAMUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system dynamic memory utilization, in unit of percentage."
::= { snAgSystemDRAM 1 }
snAgSystemDRAMTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total amount of system dynamic memory, in number of bytes."
::= { snAgSystemDRAM 2 }
snAgSystemDRAMFree OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The free amount of system dynamic memory, in number of bytes."
::= { snAgSystemDRAM 3 }
snAgSystemDRAMForBGP OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The free amount of system dynamic memory used by BGP, in number of bytes."
::= { snAgSystemDRAM 4 }
snAgSystemDRAMForOSPF OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The free amount of system dynamic memory used by OSPF, in number of bytes."
::= { snAgSystemDRAM 5 }
-- System Debug Group. You would see output of "de" command here.
snAgSystemDebug OBJECT IDENTIFIER ::= { snAgentHw 5 }
snAgSystemDebugTotalIn OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total incoming packet count. Sum of Buffer Manager and CPU read count."
::= { snAgSystemDebug 1 }
snAgSystemDebugTotalOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total outgoing packet count."
::= { snAgSystemDebug 2 }
snAgSystemDebugCpuQueueRead OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CPU Queue read count."
::= { snAgSystemDebug 3 }
snAgSystemDebugDRAMBuffer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DRAM buffer count."
::= { snAgSystemDebug 4 }
snAgSystemDebugBMBuffer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BM buffer count."
::= { snAgSystemDebug 5 }
snAgSystemDebugBMFreeBuffer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BM free buffer count."
::= { snAgSystemDebug 6 }
snAgSystemDebugBMFreeBufferMgmt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BM free buffer management count."
::= { snAgSystemDebug 7 }
snAgSystemDebugIpcGigLock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IPC GIG lock count."
::= { snAgSystemDebug 8 }
snAgSystemDebugDRAMGetError OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DRAM get error count."
::= { snAgSystemDebug 9 }
snAgSystemDebugDRAMToBMCopyFail OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DRAM to Buffer Manager copy fail count."
::= { snAgSystemDebug 10 }
-- System Temperature Table.
snAgentTempTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentTempEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to list temperatures of all the modules in the device. This
table is applicable to only those modules with temperature sensors."
::= { snAgentTemp 1 }
snAgentTempEntry OBJECT-TYPE
SYNTAX SnAgentTempEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the module temperature table."
INDEX { snAgentTempSlotNum, snAgentTempSensorId }
::= { snAgentTempTable 1 }
SnAgentTempEntry ::= SEQUENCE {
snAgentTempSlotNum
Integer32,
snAgentTempSensorId
Integer32,
snAgentTempSensorDescr
DisplayString,
snAgentTempValue
INTEGER
}
snAgentTempSlotNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The slot number of module which contains the temperature sensor
represented by this row."
::= { snAgentTempEntry 1 }
snAgentTempSensorId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The temperature sensor identifier of Slave module whose temperature is
represented by this row, for management module: sensor#1 - Intake Side Temperature
sensor# 2 - Exhaust Side Temperature."
::= { snAgentTempEntry 2 }
snAgentTempSensorDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the temperature sensor in a human readable form. This
is the same as snAgentTempSensorId, which is numeric and used to
traverse the temperature sensor table. The description provides
the meaning and purpose of this senor."
::= { snAgentTempEntry 3 }
snAgentTempValue OBJECT-TYPE
SYNTAX INTEGER (-110..250)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature of the the sensor represented by this row. Each unit
is 0.5 degrees Celcius."
::= { snAgentTempEntry 4 }
-- System Temperature Threshold Table.
snAgentTempThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentTempThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to list temperature threshold levels for 4 speeds of fan settings.
Depending on the temperature level, the fans run at diffrent speeds of RPM.
There are 4 levels of temperature settings for 4 fan speeds (low, medium,
medium-high, high). This table is applicable to only those modules with
temperature sensors. For each row, there are 2 temperature threshold values.
The high value, if reached causes the fan to run at next high level speed
and when it reduces the below the low value, the fan runs at next low spped."
::= { snAgentTemp 2 }
snAgentTempThresholdEntry OBJECT-TYPE
SYNTAX SnAgentTempThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the module temperature threshold table."
INDEX { snAgentTempThresholdModule, snAgentTempThresholdLevel }
::= { snAgentTempThresholdTable 1 }
SnAgentTempThresholdEntry ::= SEQUENCE {
snAgentTempThresholdModule
INTEGER,
snAgentTempThresholdLevel
INTEGER,
snAgentTempThresholdHighValue
INTEGER,
snAgentTempThresholdLowValue
INTEGER
}
snAgentTempThresholdModule OBJECT-TYPE
SYNTAX INTEGER {
mgmtModule(1), -- management module
slaveModule(2), -- slave/line module
switchFabricModule(3) -- switch fabric module
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The module in the system for which threshold levels represented by this
row are applicable."
::= { snAgentTempThresholdEntry 1 }
snAgentTempThresholdLevel OBJECT-TYPE
SYNTAX INTEGER {
low(1),
medium(2),
mediumHhigh(3),
high(4)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The temperature threshold level of the module for which threshold levels
represented by this row are applicable."
::= { snAgentTempThresholdEntry 2 }
snAgentTempThresholdHighValue OBJECT-TYPE
SYNTAX INTEGER (-110..250)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The high value for the temperature threshold, above which the fans would
need to operate at the next higher speed. If it reaches more than the
high threshold value for 'high' level, the module will be shutdown."
::= { snAgentTempThresholdEntry 3 }
snAgentTempThresholdLowValue OBJECT-TYPE
SYNTAX INTEGER (-110..250)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The low value for the temperature threshold, below which the fans would
need to operate at the next lower speed. This value is not applicable for
the 'low' level, as there is no more lower speeds than that."
::= { snAgentTempThresholdEntry 4 }
-- System Stacking Temperature Table.
snAgentTemp2Table OBJECT-TYPE
SYNTAX SEQUENCE OF SnAgentTemp2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to list temperatures of the modules in the device for each unit. This
table is applicable to only those modules with temperature sensors."
::= { snAgentTemp 3 }
snAgentTemp2Entry OBJECT-TYPE
SYNTAX SnAgentTemp2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the module temperature table."
INDEX { snAgentTemp2UnitNum, snAgentTemp2SlotNum, snAgentTemp2SensorId }
::= { snAgentTemp2Table 1 }
SnAgentTemp2Entry ::= SEQUENCE {
snAgentTemp2UnitNum
Integer32,
snAgentTemp2SlotNum
Integer32,
snAgentTemp2SensorId
Integer32,
snAgentTemp2SensorDescr
DisplayString,
snAgentTemp2Value
INTEGER
}
snAgentTemp2UnitNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The unit number of module which contains the temperature sensor
represented by this row."
::= { snAgentTemp2Entry 1 }
snAgentTemp2SlotNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The slot number of module which contains the temperature sensor
represented by this row."
::= { snAgentTemp2Entry 2 }
snAgentTemp2SensorId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The temperature sensor identifier of Slave module whose temperature is
represented by this row, for FastIron management module: sensor#1 - Intake Side Temperature
sensor# 2 - Exhaust Side Temperature."
::= { snAgentTemp2Entry 3 }
snAgentTemp2SensorDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the temperature sensor in a human readable form. This
is the same as snAgentTempSensorId, which is numeric and used to
traverse the temperature sensor table. The description provides
the meaning and purpose of this senor."
::= { snAgentTemp2Entry 4 }
snAgentTemp2Value OBJECT-TYPE
SYNTAX INTEGER (-110..250)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature of the sensor represented by this row. Each unit
is 0.5 degrees Celsius."
::= { snAgentTemp2Entry 5 }
fdryLicenseTable OBJECT-TYPE
SYNTAX SEQUENCE OF FdryLicenseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of licenses maintained by license sub-system."
::= { snAgentLicense 1 }
fdryLicenseEntry OBJECT-TYPE
SYNTAX FdryLicenseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in a license table."
INDEX {fdryLicensePackageName, fdryLicenseLid, IMPLIED fdryLicenseHash}
::= { fdryLicenseTable 1 }
FdryLicenseEntry ::= SEQUENCE {
fdryLicensePackageName
DisplayString,
fdryLicenseLid
DisplayString,
fdryLicenseHash
DisplayString,
fdryLicenseType
INTEGER,
fdryLicensePrecedence
Unsigned32,
fdryLicenseTrialDays
Unsigned32,
fdryLicenseTrialTimeElapsed
Unsigned32,
fdryLicenseTrialTimeLeft
Unsigned32,
fdryLicenseTrialState
INTEGER,
fdryLicenseVendorInfo
DisplayString,
fdryLicenseSlot
Integer32
}
fdryLicensePackageName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..24))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Name of the package, whose license information, this entry displays."
::= { fdryLicenseEntry 1 }
fdryLicenseLid OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..11))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"License Id (LID) of the chassis or the line module for which, this entry
displays license information."
::= { fdryLicenseEntry 2 }
fdryLicenseHash OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..17))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique hash for identifying a license entry in the system. This helps
traverse through the entries with same package name and LID."
::= { fdryLicenseEntry 3 }
fdryLicenseType OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
trial(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the license, which can be either normal or trial."
::= { fdryLicenseEntry 4 }
fdryLicensePrecedence OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the priority of a particular trial license among those having
the same package and LID. This is primarily used for determining which
license to use, when there are many trial and normal licenses with same
package name and LID."
::= { fdryLicenseEntry 5 }
fdryLicenseTrialDays OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of trial days for the license, if it's a trial license.
Otherwise, the value has no meaning for normal licenses and read
as 0 on Get operation."
::= { fdryLicenseEntry 6 }
fdryLicenseTrialTimeElapsed OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of trial hours for the license, if it's a trial license.
Otherwise, the value has no meaning for normal licenses and read
as 0 on Get operation."
::= { fdryLicenseEntry 7 }
fdryLicenseTrialTimeLeft OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of hours left for the trial license. This is derived
from the total number of hours and the cumulative number of hours
used. For a normal license, this is 0."
::= { fdryLicenseEntry 8 }
fdryLicenseTrialState OBJECT-TYPE
SYNTAX INTEGER {
invalid(1),
unused(2),
active(3),
expired(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates the state of the trial license. Invalid means the
license is not valid for this box, unused means the license is
never used, avtive means it has been used at least once and expired
means it has expired and can't be used any more."
::= { fdryLicenseEntry 9 }
fdryLicenseVendorInfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the Brocade specific package data which is an octet string.
This contains encoded information of license specific information
such as package bit mask, number of ports, etc."
::= { fdryLicenseEntry 10 }
fdryLicenseSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates the slot number of the module, the license belongs to.
There is a one to one mapping between LID and slot number, as each
module has unique LID and can be present only in one slot."
::= { fdryLicenseEntry 11 }
fdryLicensedFeatureInfo OBJECT-TYPE
SYNTAX BITS {
ospf(0),
isis(1),
bgp(2),
mpls(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The features or packages enabled/licensed on the system."
::= { snAgentLicense 2 }
brcdSwPackageFname OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the release package file or manifest file (including path)
currently associated with the system.
When the object is not used, the value is a zero length string."
::= { brcdSwPackageUpgrade 1 }
brcdSwPackageLoad OBJECT-TYPE
SYNTAX INTEGER {
none(1),
tftpToPrimary(2),
tftpToSecondary(3),
tftpToMgmtModulePrimaryIntfModuleSecondary(4),
tftpToMgmtModuleSecondaryIntfModulePrimary(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action object to upgrade the system using a release package.
none(1) is the value after the system comes up and should not be used for set-request.
The following values will download the release package from a TFTP server and upgrade the system :
tftpToPrimary(2) installs both MP and LP application images to primary code.
tftpToSecondary(3) installs both MP and LP application images to secondary code.
tftpToMgmtModulePrimaryIntfModuleSecondary (4) installs MP application image to primary code and the LP
application images to secondary code.
tftpToMgmtModuleSecondaryIntfModulePrimary (5) installs MP application image to secondary code and the LP
application images to primary code."
::= { brcdSwPackageUpgrade 2 }
brcdSwPackageLoadStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
started(2),
internalError(3),
manifestFileDownloadError(4),
manifestFileValidationError(5),
downloadingManagementModuleBoot (6),
downloadingManagementModuleMonitor (7),
downloadingManagementModuleApplication (8),
downloadingInterfaceModuleBoot (9),
downloadingInterfaceModuleMonitor (10),
downloadingInterfaceModuleApplication (11),
downloadingInterfaceModuleFpga (12),
downloadingFpgaMBridge (13),
downloadingFpgaSBridge (14),
downloadingFpgaHBridge (15),
upgradingManagementModuleBoot (16),
upgradingManagementModuleMonitor (17),
upgradingManagementModuleApplication (18),
upgradingInterfaceModuleBoot (19),
upgradingInterfaceModuleMonitor (20),
upgradingInterfaceModuleApplication (21),
upgradingInterfaceModuleFpga (22),
upgradingFpgaMBridge (23),
upgradingFpgaSBridge (24),
upgradingFpgaHBridge (25)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the progress of the upgrade operation.
<TBD: more description> "
::= { brcdSwPackageUpgrade 3 }
brcdSwPackageUpgradeAllImages OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To specify an all-image upgrade.
If set to true(1), the upgrade sequence will include the MP and
LP BOOT images, and MP FPGA images (MBRIDGE/MBRIDGE32 and
SBRIDGE/HSBRIDGE). For CES/CER the upgrade sequence
includes the boot image.
Default is false(2) which will upgrade only the MP and LP Monitor
images, MP and LP Application images, and LP Bundled FPGA. For
CES/CER, only the monitor, application, and FPGA images will be upgraded.
For a read operation, this will always return false(2)."
DEFVAL { false }
::= { brcdSwPackageUpgrade 4 }
brcdSwPackageUpgradeResultTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrcdSwPackageUpgradeResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the summary of the upgrade operation."
::= { brcdSwPackageUpgrade 5 }
brcdSwPackageUpgradeResultEntry OBJECT-TYPE
SYNTAX BrcdSwPackageUpgradeResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"<TBD>"
INDEX { brcdSwPackageUpgradeResultIndex }
::= { brcdSwPackageUpgradeResultTable 1 }
BrcdSwPackageUpgradeResultEntry::= SEQUENCE {
brcdSwPackageUpgradeResultIndex
Unsigned32,
brcdSwPackageUpgradeResultImageType
BrcdImageType,
brcdSwPackageUpgradeResultStatus
INTEGER,
brcdSwPackageUpgradeResultTimeStamp
TimeStamp,
brcdSwPackageUpgradeResultDescription
DisplayString
}
brcdSwPackageUpgradeResultIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The sequential index, or upgrade step."
::= { brcdSwPackageUpgradeResultEntry 1 }
brcdSwPackageUpgradeResultImageType OBJECT-TYPE
SYNTAX BrcdImageType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The associated image type for this step of upgrade process."
::= { brcdSwPackageUpgradeResultEntry 2 }
brcdSwPackageUpgradeResultStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
downloadFailed(2),
installFailed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The upgrade status for this particular image upgrade."
::= { brcdSwPackageUpgradeResultEntry 3 }
brcdSwPackageUpgradeResultTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The timestamp when this upgrade step was performed."
::= { brcdSwPackageUpgradeResultEntry 4 }
brcdSwPackageUpgradeResultDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Summary description for this particular image upgrade.
This is empty when brcdSwPackageLoadResultStatus is 'ok'."
::= { brcdSwPackageUpgradeResultEntry 5 }
brcdSwIntfModAutoUpgradeMode OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
disabled(2),
tftp(3),
slot1(4),
slot2(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the mode of LP Auto-upgrade.
<TBD: more description> "
::= { brcdSwIntfModAutoUpgrade 1 }
brcdSwIntfModAutoUpgradeTftpAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TFTP server IP address Type. Supported address types are ipv4(1) and ipv6(2).
<TBD: more description>"
::= { brcdSwIntfModAutoUpgrade 2 }
brcdSwIntfModAutoUpgradeTftpAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TFTP server IP address. <TBD: more description>"
::= { brcdSwIntfModAutoUpgrade 3 }
brcdSwIntfModAutoUpgradeSrcPath OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the path to the topmost directory of the release
package relative to the root directory.
If the source is a TFTP server, the root is the TFTP root.
If the source is slot1 or slot2, the root is top-level directory '/'"
::= { brcdSwIntfModAutoUpgrade 4 }
brcdSwIntfModAutoUpgradeAllImages OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to specify an all-image upgrade. If set to true(1),
the upgrade sequence will include the LP BOOT image.
Default is false(2), which will upgrade only the LP FPGA images.
For a read operation, this will return the configured value."
DEFVAL { false }
::= { brcdSwIntfModAutoUpgrade 5 }
END