BTI8xx-SYSTEM-MIB
|
|
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
IpAddress,
|
|
Unsigned32,
|
|
Integer32,
|
|
Gauge32,
|
|
TimeTicks,
|
|
Counter32 FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
DisplayString,
|
|
MacAddress,
|
|
TruthValue,
|
|
DateAndTime,
|
|
RowStatus FROM SNMPv2-TC -- [RFC2579]
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP FROM SNMPv2-CONF
|
|
InterfaceIndex,
|
|
ifIndex FROM IF-MIB -- [RFC2863]
|
|
PerfCurrentCount,
|
|
PerfIntervalCount,
|
|
PerfTotalCount FROM PerfHist-TC-MIB -- [RFC3593]
|
|
mainSystem FROM BTI8xx-TC-MIB;
|
|
|
|
systemConfig MODULE-IDENTITY
|
|
|
|
LAST-UPDATED "201511301200Z" -- Monday, Nov 30, 12:00:00 KST 2015
|
|
ORGANIZATION "Actus Networks Ltd."
|
|
CONTACT-INFO "
|
|
Support: +82-2-26535666
|
|
R&D: +82-2-26535666
|
|
Fax: +82-2-26534662
|
|
Email: ymkim@actusnetworks.com
|
|
"
|
|
|
|
DESCRIPTION "This is a top-level MIB for Actus whose purpose is to lay out
|
|
the top-level objects in the OID hierarchy from which
|
|
BTI8xx MIB OIDs descend."
|
|
|
|
REVISION "201511301200Z" -- Monday, Nov 30, 12:00:00 KST 2015
|
|
DESCRIPTION "
|
|
*1. Change the Syntax(for silvercreek tool).
|
|
1.1. Change the syntax range. (1..32) -> (0..32)
|
|
ftpUserName
|
|
ftpUserPasswd
|
|
"
|
|
|
|
REVISION "201511201200Z" -- Friday, Nov 20, 12:00:00 KST 2015
|
|
DESCRIPTION "
|
|
*1. Change the MAX-ACCESS(for silvercreek tool).
|
|
'not-accessible' -> 'read-only'
|
|
-imageInfoIndex
|
|
|
|
*2. Change the Syntax(for silver creek tool).
|
|
2.1. DisplayString -> OCTET STRING
|
|
systemName
|
|
systemHWVersion
|
|
systemSWVersion
|
|
systemSWDateAndTime
|
|
systemProductName
|
|
ftpUserName
|
|
ftpUserPasswd
|
|
cfgFileName
|
|
upgradeImageSWFileName
|
|
upgradeImageSWDateAndTime
|
|
imageInfoVersion
|
|
imageInfoCreated
|
|
timezone
|
|
systemTime
|
|
|
|
2.2. Delete the syntax value range
|
|
lastSaveTime
|
|
|
|
*3. MIB code sorting.
|
|
"
|
|
REVISION "201509071300Z" -- Monday, Sep 07, 13:00:00 KST 2015
|
|
DESCRIPTION "
|
|
*1. Change the description attribute of 'miscellaneous'
|
|
timezone
|
|
- MET/IST/ACT/CNT : +30 minutes
|
|
- EAT : description
|
|
tempLowThreshold
|
|
"
|
|
|
|
REVISION "201410291200Z" -- Wednesday, Oct 29, 12:00:00 KST 2014
|
|
DESCRIPTION "
|
|
*1. Change the sytax size
|
|
DisplayString(SIZE(0..256)) -> DisplayString(SIZE(0..255))
|
|
"
|
|
|
|
REVISION "201408111200Z" -- Monday, Aug 11, 12:00:00 KST 2014
|
|
DESCRIPTION "
|
|
*1. This value option is changed.
|
|
upgradeImageSW
|
|
- upgradeByFtp(1) -> updateImageFile(1)
|
|
- upgradeByTftp(2)-> upgradeImage(2)
|
|
*2. Unused value
|
|
upgradeImageSWLocation
|
|
"
|
|
|
|
REVISION "201407151200Z" -- Tuesday, Jul 15, 12:00:00 KST 2014
|
|
DESCRIPTION "
|
|
*1. Delete the bridgeConfig
|
|
"
|
|
|
|
REVISION "201406181200Z" -- Wednesday, Jun 18, 12:00:00 KST 2014
|
|
DESCRIPTION "
|
|
*1. This value range is changed the 60 to 35791.
|
|
autoLogoutTime
|
|
*2. Update the timezone description
|
|
"
|
|
|
|
REVISION "201312271200Z" -- Monday, Dec 30, 12:00:00 KST 2013
|
|
DESCRIPTION "Initial version of MIB."
|
|
|
|
::= { mainSystem 1 }
|
|
|
|
-- ==============================================================
|
|
-- privateManagement:configManagement:mainSystem:systemConfig ==
|
|
-- ==============================================================
|
|
systemManagement OBJECT IDENTIFIER ::= { systemConfig 1 }
|
|
accessInfo OBJECT IDENTIFIER ::= { systemConfig 2 }
|
|
consoleInformation OBJECT IDENTIFIER ::= { systemConfig 3 }
|
|
|
|
|
|
-- ===============================================================================
|
|
-- privateManagement:configManagement:mainSystem:systemConfig:systemManagement ==
|
|
-- ===============================================================================
|
|
systemInfo OBJECT IDENTIFIER ::= { systemManagement 1 }
|
|
configAndImageMgmt OBJECT IDENTIFIER ::= { systemManagement 2 }
|
|
miscellaneous OBJECT IDENTIFIER ::= { systemManagement 3 }
|
|
--bridgeConfig OBJECT IDENTIFIER ::= { systemManagement 4 }
|
|
mgmtVlanConfig OBJECT IDENTIFIER ::= { systemManagement 5 }
|
|
--ztpConfig OBJECT IDENTIFIER ::= { systemManagement 6 }
|
|
|
|
|
|
-- ==========================================================================================
|
|
-- privateManagement:configManagement:mainSystem:systemConfig:systemManagement:systemInfo ==
|
|
-- ==========================================================================================
|
|
systemName OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The System Name (Network Element Name)"
|
|
::= { systemInfo 1 }
|
|
|
|
autoLogoutTime OBJECT-TYPE
|
|
SYNTAX Integer32 (0..35791)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The auto-logout timer in minute of console/telnet/web based managment.
|
|
0 means auto logout is disabled. 0~35791 are applicable."
|
|
::= { systemInfo 2 }
|
|
|
|
systemUpTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"On site time- time after the last power up
|
|
Second resolution (also year)
|
|
Format: YY-DDD-HH-MM-SS (Year, Day, HR, Minute,Second)"
|
|
::= { systemInfo 3 }
|
|
|
|
systemHWVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"H/W Version of Main System"
|
|
::= { systemInfo 4 }
|
|
|
|
systemSWVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"S/W Version of Main System"
|
|
::= { systemInfo 5 }
|
|
|
|
systemSWDateAndTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..30))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"S/W Date and Time of Main System(ex. Apr 8 2010 14:00:01)"
|
|
::= { systemInfo 6 }
|
|
|
|
systemTemperature OBJECT-TYPE
|
|
SYNTAX Integer32(0..1000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System Temperature of Main System(Celsius)"
|
|
::= { systemInfo 7 }
|
|
|
|
systemProductName OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE (0..40))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The System Product Name"
|
|
::= { systemInfo 8 }
|
|
|
|
-- ===========================================================================================
|
|
-- pManagement:configManagement:mainSystem:systemConfig:systemManagement:configAndImageMgmt ==
|
|
-- ===========================================================================================
|
|
serverConfig OBJECT IDENTIFIER ::= { configAndImageMgmt 1 }
|
|
configMgmt OBJECT IDENTIFIER ::= { configAndImageMgmt 2 }
|
|
imageMgmt OBJECT IDENTIFIER ::= { configAndImageMgmt 3 }
|
|
|
|
-- ========================================================================================================
|
|
-- pManagement:configManagement:mainSystem:systemConfig:systemManagement:configAndImageMgmt:serverConfig ==
|
|
-- ========================================================================================================
|
|
serverIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ftp or Tftp Server Ip Address"
|
|
::= { serverConfig 1 }
|
|
|
|
ftpUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FtpUserName"
|
|
::= { serverConfig 2 }
|
|
|
|
ftpUserPasswd OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FtpUserPasswd"
|
|
::= { serverConfig 3 }
|
|
|
|
serverInterfaceType OBJECT-TYPE
|
|
SYNTAX INTEGER { oob(0), inBand(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Server type
|
|
oob : Management Interface
|
|
inBand : In-band Interface"
|
|
::= { serverConfig 4 }
|
|
|
|
|
|
-- ======================================================================================================
|
|
-- pManagement:configManagement:mainSystem:systemConfig:systemManagement:configAndImageMgmt:configMgmt ==
|
|
-- ======================================================================================================
|
|
cfgFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object is ConfigFile BackUp Name."
|
|
::= { configMgmt 1 }
|
|
|
|
cfgFileControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (0),
|
|
backUpByFtp (1),
|
|
restoreByFtp (2),
|
|
backupByTftp (3),
|
|
restoreByTftp (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object is Control Config File
|
|
BackUp: Configfile backup and upload to server.
|
|
Restore : Configfile download and restore."
|
|
::= { configMgmt 2 }
|
|
|
|
cfgFileStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (0),
|
|
backupSuccess (1),
|
|
restoreSuccess (2),
|
|
inProgress (3),
|
|
fileNotFound (4),
|
|
connnectionFail (5),
|
|
logInFail (6),
|
|
diskFull (7),
|
|
otherError (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the state of configfile backup and download."
|
|
::= { configMgmt 3 }
|
|
|
|
upgradeImageSWFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Upgrade Image FileName wiht the remote path.
|
|
the remote path is different from window-based ftp-server and linux-based ftp-server.
|
|
Window-based ftp-server : folder classification is '\'. (\image\bti800_main.img)
|
|
Linux-based ftp-server : folder classification is '/'. (/image/bti800_main.img)
|
|
"
|
|
::= { imageMgmt 1 }
|
|
|
|
-- upgradeImageSWLocation OBJECT-TYPE
|
|
-- SYNTAX INTEGER{ primary(0), secondary(1) }
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "The date and time when upgradeImageSWStatus happen. "
|
|
-- DEFVAL { primary }
|
|
-- ::= { imageMgmt 2 }
|
|
|
|
upgradeImageSW OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (0),
|
|
updateImageFile (1),
|
|
upgradeImage (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object provides the operator the ability to upgrade the image to a file.
|
|
The initial value would be none(0).
|
|
Before starting update image, upgradeImageSWFilenName and ftpConfig or tftpConfig value should be set.
|
|
|
|
updateImageFile(1) : Download the image file(by FTP server).
|
|
upgradeImage(2) : Upgrade image file.
|
|
|
|
This operation need long period, so Please checked the upgradeImageSWStatus.
|
|
Reboot should be executed to finish upgrade procedure when load upgrade will be passed.
|
|
"
|
|
::= { imageMgmt 3 }
|
|
|
|
upgradeImageSWStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (0),
|
|
success (1),
|
|
inProgress (2),
|
|
diskIsFull (3),
|
|
fileSizeError (4),
|
|
fileOpenError (5),
|
|
fileCRCError (6),
|
|
flashEraseError(7),
|
|
flashWriteError(8),
|
|
unknownError (9),
|
|
upgradeDeliveryInProgress(101),
|
|
upgradeDeliveryFailed (102),
|
|
upgradeDeliverySuccess (103),
|
|
upgradeCheckInProgress (104),
|
|
upgradeCheckFailed (105),
|
|
upgradeCheckSuccess (106),
|
|
upgradeLoadInProgress (107),
|
|
upgradeLoadFailed (108),
|
|
upgradeLoadSuccess1stDone(109),
|
|
upgradeInvokeInProgress (110),
|
|
upgradeInvokeFailed (111),
|
|
upgradeInvokeSuccess2ndDone (112),
|
|
upgradeCommitInProgress (113),
|
|
upgradeCommitFailed (114),
|
|
upgradeImagelatestVersion(115)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The current status of the upgrade operation.
|
|
- fileSizeError : image file is not matched image bank
|
|
|
|
The initial value should be none(0) and also it should be none
|
|
when get the imageFpga file success from the server.
|
|
|
|
The valus inProgress(2) is returned while upgradeImage.
|
|
The valus diskIsFull(3) is returned when file System is full and imageSW file is not written.
|
|
The valus fileSizeError(4) is returned when expected file size is not match with downloaded file.
|
|
The valus fileOpenError(5) is returned when there is a problem on downloaded file.
|
|
The valus fileCRCError(6) is returned whne there is a checksum error on downloaded file.
|
|
The valus flashEraseError(7) is returned when there is a problem on erasing flash.
|
|
The valus flashWriteError(8) is returned when there is a problem on writing flash.
|
|
The valus unknownError(9) is returned when there is a problem with others.
|
|
|
|
For imageSW upgrade/backup, it follows below procedures.
|
|
1) The value UpgradeLoadSuccess1stDone(109) is returned when
|
|
the upgradeImage command executed successfully.
|
|
2) The value UpgradeInvokeSuccess2ndDone(112) is returned when
|
|
reboot after upgradeImage success.
|
|
3) The value success(1) is returned when
|
|
the backupImage command executed successfully.
|
|
|
|
For others, it is for retrieving the status of upgrade processing.
|
|
upgradeDeliveryInProgress(101)
|
|
upgradeDeliveryFailed (102)
|
|
upgradeDeliverySuccess (103)
|
|
Delivery stage is that imageSW file is downloaded.
|
|
upgradeCheckInProgress (104)
|
|
upgradeCheckFailed (105)
|
|
upgradeCheckSuccess (106)
|
|
Check stage is that the downloaded file is checked for healthy.
|
|
upgradeLoadInProgress (107)
|
|
upgradeLoadFailed (108)
|
|
Load stage is that the downloaded imageSW is written on the primary bank.
|
|
upgradeInvokeInProgress (110)
|
|
upgradeInvokeFailed (111)
|
|
Invoke stage can be issued only when upgrade state is Load passed. The product is restarted from primary bank
|
|
with new load. If the primary bank load is corrupted, the product should start running from secondary bank.
|
|
upgradeCommitInProgress (113)
|
|
upgradeCommitFailed (114)
|
|
Commit stage is that it can be executed only after Invoke Upgrade stage when it is successfully completed
|
|
the image is copied from the primary to the secondary bank and only when the system started from primary bank.
|
|
The upgradeXXXX return codes are only for imageSW.
|
|
"
|
|
::= { imageMgmt 4 }
|
|
|
|
upgradeImageSWDateAndTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time when upgradeImageSWStatus happen. "
|
|
::= { imageMgmt 5 }
|
|
|
|
imageInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ImageInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ImageInformation Table. It includes the information of the Primary bank and the Secondary bank "
|
|
::= { imageMgmt 10 }
|
|
|
|
imageInfoEntry OBJECT-TYPE
|
|
SYNTAX ImageInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ImageInfoTable Entry."
|
|
INDEX { imageInfoIndex }
|
|
::= { imageInfoTable 1 }
|
|
|
|
ImageInfoEntry ::=
|
|
SEQUENCE {
|
|
imageInfoIndex INTEGER,
|
|
imageInfoVersion OCTET STRING,
|
|
imageInfoCreated OCTET STRING,
|
|
imageInfoSize Integer32,
|
|
imageInfoCurrent INTEGER
|
|
}
|
|
|
|
imageInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER{ primary(1), secondary(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the Image."
|
|
::= { imageInfoEntry 1 }
|
|
|
|
imageInfoVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0.. 32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Version of the Image."
|
|
::= { imageInfoEntry 2 }
|
|
|
|
imageInfoCreated OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0.. 128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Created of the Image."
|
|
::= { imageInfoEntry 3 }
|
|
|
|
imageInfoSize OBJECT-TYPE
|
|
SYNTAX Integer32(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Size of the Image.(bytes)"
|
|
::= { imageInfoEntry 4 }
|
|
|
|
imageInfoCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER{ none(0), active(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Show Current Image"
|
|
::= { imageInfoEntry 5 }
|
|
|
|
|
|
-- ======================================================================================
|
|
-- pManagement:configManagement:mainSystem:systemConfig:systemManagement:miscellaneous ==
|
|
-- ======================================================================================
|
|
reboot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (0),
|
|
reboot(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing this object as other than none will make the software reboot.
|
|
reboot means slot1, slot2 and Main reboot simultaneously.
|
|
This process takes a few minutes."
|
|
::= { miscellaneous 1 }
|
|
|
|
save OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
save(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing this object other than none will save the current running configuration to the non-volatile memory of main"
|
|
::= { miscellaneous 2 }
|
|
|
|
lastSaveTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is shows the last save time of base system"
|
|
::= { miscellaneous 3 }
|
|
|
|
timezone OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timezone configuration of the device. The examples are kst, KST, cnt etc.
|
|
act - ACT. Australia Central Time(GMT+9:30)
|
|
aet - AET. Australia Eastern Time(GMT+10:00)
|
|
agt - AGT. Argentina Standard Time(GMT-3:00)
|
|
art - ART. (Arabic) Egypt Standard Time(GMT+2:00)
|
|
ast - AST. Alaska Standard Time(GMT-9:00)
|
|
bet - BET. Brazil Eastern Time(GMT-3:00)
|
|
bst - BST. Bangladesh Standard Time(GMT+6:00)
|
|
cat - CAT. Central African Time(GMT-1:00)
|
|
cnt - CNT. Canada Newfoundland Time(GMT-3:30)
|
|
cst - CST. Central Standard Time(GMT-6:00)
|
|
ctt - CTT. China Taiwan Time(GMT+8:00)
|
|
eat - EAT. Eastern African Time(GMT+3:00)
|
|
ect - ECT. European Central Time(GMT+1:00)
|
|
edt - EDT. Eastern Daylight Time(GMT-4:00)
|
|
eet - EET. Eastern European Tim(GMT+2:00)
|
|
est - EST. Eastern Standard Time(GMT-5:00)
|
|
gmt - GMT. Greenwich Mean Time
|
|
hst - HST. Hawaii Standard Time(GMT-10:00)
|
|
iet - IET. Indiana Eastern Standard Time(GMT-5:00)
|
|
ist - IST. India Standard Time(GMT+5:30)
|
|
jst - JST. Japan Standard Time(GMT+9:00)
|
|
kst - KST. Korea Standard Time(GMT+9:00)
|
|
met - MET. Middle East Time(GMT+3:30)
|
|
mit - MIT. Midway Islands Time(GMT-11:00)
|
|
mst - MST. Mountain Standard Time(GMT-7:00)
|
|
net - NET. Near East Time(GMT+4:00)
|
|
nst - NST. New Zealand Standard Time(GMT+12:00)
|
|
plt - PLT. Pakistan Lahore Time(GMT+5:00)
|
|
pnt - PNT. Phoenix Standard Time(GMT-7:00)
|
|
prt - PRT. Puerto Rico and US Virgin Islands Time(GMT-4:00)
|
|
pst - PST. Pacific Standard Time(GMT-8:00)
|
|
sst - SST. Solomon Standard Time(GMT+11:00)
|
|
utc - UTC. Universal Coordinated Time
|
|
vst - VST. Vietnam Standard Time(GMT+7:00)
|
|
"
|
|
::= { miscellaneous 4 }
|
|
|
|
systemTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"system Current Time
|
|
- Time Format : Nov 15 20:53:40 2009"
|
|
::= { miscellaneous 5 }
|
|
|
|
lastCommand OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..512))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Save the last command line and time."
|
|
::= { miscellaneous 6 }
|
|
|
|
fanCtrlStartTemp OBJECT-TYPE
|
|
SYNTAX Integer32(0..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan Start Temperature : between 0 and 100"
|
|
::= { miscellaneous 7 }
|
|
|
|
fanCtrlStopTemp OBJECT-TYPE
|
|
SYNTAX Integer32(-30..30)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan Stop Temperature : between -30 and 30"
|
|
::= { miscellaneous 8 }
|
|
|
|
fanRpmConfig OBJECT-TYPE
|
|
SYNTAX Integer32(5000..20000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan Rpm : between 5000 and 20000"
|
|
::= { miscellaneous 9 }
|
|
|
|
fanLowTolerance OBJECT-TYPE
|
|
SYNTAX Integer32(10..80)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan Low Under Flow Tolerance : between 10% to 80%"
|
|
::= { miscellaneous 10 }
|
|
|
|
fanLowToleranceValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan Low Under Flow Tolerance RPM"
|
|
::= { miscellaneous 11 }
|
|
|
|
fanHighTolerance OBJECT-TYPE
|
|
SYNTAX Integer32(10..80)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan High Over Flow Tolerance : between 10% to 80%"
|
|
::= { miscellaneous 12 }
|
|
|
|
fanHighToleranceValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan HighOver Flow Tolerance RPM"
|
|
::= { miscellaneous 13 }
|
|
|
|
tempHighThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(0..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High temperature threshold(0 to 100)"
|
|
::= { miscellaneous 14 }
|
|
|
|
tempLowThreshold OBJECT-TYPE
|
|
SYNTAX Integer32(-30..-1)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low temperature threshold(-1 to -30)"
|
|
::= { miscellaneous 15 }
|
|
|
|
|
|
-- =====================================================================================
|
|
-- pManagement:configManagement:mainSystem:systemConfig:systemManagement:bridgeConfig ==
|
|
-- =====================================================================================
|
|
-- bridgeMode OBJECT-TYPE
|
|
-- SYNTAX INTEGER{ customer(1), provider(2), providerBackbone(3)}
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- ""
|
|
-- ::= { bridgeConfig 1 }
|
|
|
|
-- bridgeageingTime OBJECT-TYPE
|
|
-- SYNTAX Integer32(10..1000000)
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- ""
|
|
-- ::= { bridgeConfig 2 }
|
|
|
|
-- ========================================================================================
|
|
-- pManagement:configManagement:mainSystem:systemConfig:systemManagement:mgmtVlanConfig ==
|
|
-- ========================================================================================
|
|
mgmtOuterVlan OBJECT-TYPE
|
|
SYNTAX Integer32(1..4094)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" "
|
|
::= { mgmtVlanConfig 1 }
|
|
|
|
mgmtOuterVlanPriority OBJECT-TYPE
|
|
SYNTAX Integer32(0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" "
|
|
::= { mgmtVlanConfig 2 }
|
|
|
|
mgmtInnerVlan OBJECT-TYPE
|
|
SYNTAX Integer32(0..4094)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"0 is untagged"
|
|
::= { mgmtVlanConfig 3 }
|
|
|
|
mgmtInnerVlanPriority OBJECT-TYPE
|
|
SYNTAX Integer32(0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" "
|
|
::= { mgmtVlanConfig 4 }
|
|
|
|
|
|
-- ==================================================================
|
|
-- pManagement:configManagement:mainSystem:systemConfig:accessInfo ==
|
|
-- ==================================================================
|
|
pInbandIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ip Adddress of inband Primary management ETH port"
|
|
::= { accessInfo 1 }
|
|
|
|
pInbandNetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NetMask of inband Primary management ETH port"
|
|
::= { accessInfo 2 }
|
|
|
|
pInbandNetworkAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network address of Inband Primary management ETH port"
|
|
::= { accessInfo 3 }
|
|
|
|
pInbandMACAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC address of inband Primary management ETH port"
|
|
::= { accessInfo 4 }
|
|
|
|
pOOBIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of OOB(Out of Band) ETH port"
|
|
::= { accessInfo 5 }
|
|
|
|
pOOBNetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NetMask of OOB(Out of band) ETH port"
|
|
::= { accessInfo 6 }
|
|
|
|
pOOBNetworkAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network address of OOB(Out of band) ETH port"
|
|
::= { accessInfo 7 }
|
|
|
|
pOOBMACAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC address of OOB(Out of band) port"
|
|
::= { accessInfo 8 }
|
|
|
|
pDefaultGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default Gateway - 0.0.0.0 : disable"
|
|
::= { accessInfo 9 }
|
|
|
|
|
|
-- ==========================================================================
|
|
-- pManagement:configManagement:mainSystem:systemConfig:consoleInformation ==
|
|
-- ==========================================================================
|
|
consoleBaudRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bps9600 (1),
|
|
bps19200 (2),
|
|
bps38400 (3),
|
|
bps57600 (4),
|
|
bps115200 (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The baud rate of the console port."
|
|
::= { consoleInformation 1 }
|
|
|
|
consoleCharSize OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sevenBits(7),
|
|
eightBits(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The character size of the console port."
|
|
::= { consoleInformation 2 }
|
|
|
|
consoleParityBits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noParity (1),
|
|
evenParity(2),
|
|
oddParity (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The parity bits of the console port."
|
|
::= { consoleInformation 3 }
|
|
|
|
consoleStopBits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
one (1),
|
|
two (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The stop bits of the console port."
|
|
::= { consoleInformation 4 }
|
|
|
|
consoleFlowControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
hardware (2),
|
|
xonXoff (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow control of the console port."
|
|
::= { consoleInformation 5 }
|
|
|
|
|
|
END
|