E5-110-TRAPS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
|
|
OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
DisplayString, ifIndex
|
|
FROM RFC1213-MIB
|
|
iesChassisId,iesSlotId
|
|
FROM E5-110-IESCOMMON-MIB
|
|
e5x110
|
|
FROM E5-110-MIB;
|
|
|
|
trap OBJECT IDENTIFIER ::= { e5x110 12 }
|
|
|
|
----------------------------------------
|
|
-- trap
|
|
----------------------------------------
|
|
|
|
object OBJECT IDENTIFIER ::= { trap 1 }
|
|
equipment OBJECT IDENTIFIER ::= { trap 3 }
|
|
systrap OBJECT IDENTIFIER ::= { trap 4 }
|
|
interface OBJECT IDENTIFIER ::= { trap 8 }
|
|
e5Alarm OBJECT IDENTIFIER ::= { trap 9 }
|
|
--------------------
|
|
-- object
|
|
--------------------
|
|
|
|
eqptAlarmInputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of alarm input."
|
|
::= { object 2 }
|
|
|
|
eqptAlarmInputName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Name of alarm input."
|
|
::= { object 8 }
|
|
|
|
sysMacAntiSpoofOrig OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Original port of Mac-AntiSpoofing."
|
|
::= { object 9 }
|
|
|
|
sysMacAntiSpoofNew OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The New port of Mac-AntiSpoofing."
|
|
::= { object 10 }
|
|
|
|
sysMacAntiSpoofMAC OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MAC of Mac-AntiSpoofing."
|
|
::= { object 11 }
|
|
|
|
sysAlarmOrigSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical(1),
|
|
major(2),
|
|
minor(3),
|
|
info(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The original severity of alarm."
|
|
::= { object 12 }
|
|
|
|
sysAlarmNewSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical(1),
|
|
major(2),
|
|
minor(3),
|
|
info(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The new severity of alarm."
|
|
::= { object 13 }
|
|
|
|
sysAlarmConfId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The changed severity of alarm condition ID.
|
|
5000:adslLine_up
|
|
5001:adslLine_down
|
|
5002:adslPerf_lol_thresh
|
|
5003:adslPerf_lof_thresh
|
|
5004:adslPerf_los_thresh
|
|
5005:adslPerf_lop_thresh
|
|
5006:adslPerf_es_thresh
|
|
5007:adslPerf_ses_thresh
|
|
5008:adslPerf_uas_thresh
|
|
5009:adslAtuc_loftrap
|
|
5010:adslAtuc_lostrap
|
|
5011:adslAtur_loftrap
|
|
5012:adslAtur_lostrap
|
|
5013:adslAtur_lprtrap
|
|
5014:ad_dhcp_rt_full
|
|
5015:ad_dhcp_dm_conflict
|
|
5016:ad_dhcp_entry_full
|
|
5017:ad_dhcp_ip_dup
|
|
5018:ad_dhcp_mac_dup
|
|
10000:eqptVol_err
|
|
10001:eqptEqpttemp_err
|
|
10002:eqptFan_err
|
|
10003:eqptHw_rtc_fail
|
|
10004:eqptHw_mon_fail
|
|
10005:eqptCold_start
|
|
10006:eqptWarm_start
|
|
10007:eqptAlm_input
|
|
10008:eqptI2c_err
|
|
10009:eqptAlm_input2
|
|
10010:eqptAlm_input3
|
|
15000:sysReboot
|
|
15001:sysAco
|
|
15002:sysAlm_clear
|
|
15003:sysLogin_fail
|
|
15004:sysAnti_spoofing
|
|
15005:sysAlm_svrty_change
|
|
20000:enetUp
|
|
20001:enetDown
|
|
"
|
|
::= { object 14 }
|
|
|
|
-- intfCfmCcmErrorCause OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- noDefect(1),
|
|
-- rdiReceived(2),
|
|
-- macDownReceivedFromDownMEP(3),
|
|
-- lostConnectionToRemoteMEP(4),
|
|
-- configurationError(5),
|
|
-- maintenanceDomainCrossConnect(6)
|
|
-- }
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- ""
|
|
-- ::= { object 55 }
|
|
|
|
--------------------
|
|
-- equipment
|
|
--------------------
|
|
|
|
eqptHWMonitorFailure NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hardware monitor diagnosis is failed."
|
|
::= { equipment 1 }
|
|
|
|
--------------------
|
|
-- systrap
|
|
--------------------
|
|
|
|
sysMacAntiSpoofing NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
sysMacAntiSpoofOrig,
|
|
sysMacAntiSpoofNew,
|
|
sysMacAntiSpoofMAC
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC Anti-spoofing."
|
|
::= { systrap 1 }
|
|
|
|
sysAlarmCutoffEnable NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm cutoff is activated."
|
|
::= { systrap 2 }
|
|
|
|
sysAlarmClearEnable NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm clear is activated."
|
|
::= { systrap 3 }
|
|
|
|
sysLoginFailure NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User login is failed."
|
|
::= { systrap 4 }
|
|
|
|
sysAlarmSvrtyChange NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm severity is changed."
|
|
::= { systrap 5 }
|
|
|
|
--------------------
|
|
-- interface
|
|
--------------------
|
|
|
|
-- cfmCcmError NOTIFICATION-TYPE
|
|
-- OBJECTS {
|
|
-- dot1agCfmMdMdLevel,
|
|
-- dot1agCfmVlanPrimaryVid,
|
|
-- dot1agCfmMepIdentifier,
|
|
-- intfCfmCcmErrorCause
|
|
-- }
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- ""
|
|
-- ::= { interface 1 }
|
|
|
|
--------------------
|
|
-- e5Alarm
|
|
--------------------
|
|
|
|
e5AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF E5AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table holds all the active alarms"
|
|
::= { e5Alarm 1 }
|
|
|
|
|
|
e5AlarmNotify NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
e5AlarmObjectClass,
|
|
e5AlarmObjectInstance1,
|
|
e5AlarmObjectInstance2,
|
|
e5AlarmObjectInstance3,
|
|
e5AlarmObjectInstance4,
|
|
e5AlarmType,
|
|
e5AlarmSeverity,
|
|
e5AlarmTimeStamp,
|
|
e5AlarmServiceAffecting,
|
|
e5AlarmText,
|
|
e5AlarmTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"E5 device alarm notification."
|
|
::= { e5Alarm 2 }
|
|
|
|
|
|
e5AlarmEntry OBJECT-TYPE
|
|
SYNTAX E5AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "List of attributes regarding alarm table"
|
|
INDEX { e5AlarmObjectClass, e5AlarmObjectInstance1, e5AlarmObjectInstance2,
|
|
e5AlarmObjectInstance3, e5AlarmObjectInstance4,
|
|
e5AlarmObjectInstance5, e5AlarmObjectInstance6,
|
|
e5AlarmObjectInstance7, e5AlarmObjectInstance8, e5AlarmType }
|
|
::= { e5AlarmTable 1 }
|
|
|
|
E5AlarmEntry ::= SEQUENCE {
|
|
e5AlarmObjectClass INTEGER,
|
|
e5AlarmObjectInstance1 INTEGER,
|
|
e5AlarmObjectInstance2 INTEGER,
|
|
e5AlarmObjectInstance3 INTEGER,
|
|
e5AlarmObjectInstance4 INTEGER,
|
|
e5AlarmObjectInstance5 INTEGER,
|
|
e5AlarmObjectInstance6 INTEGER,
|
|
e5AlarmObjectInstance7 INTEGER,
|
|
e5AlarmObjectInstance8 INTEGER,
|
|
e5AlarmType INTEGER,
|
|
e5AlarmSeverity INTEGER,
|
|
e5AlarmTimeStamp OCTET STRING,
|
|
e5AlarmServiceAffecting INTEGER,
|
|
e5AlarmLocationInfo INTEGER,
|
|
e5AlarmText OCTET STRING,
|
|
e5AlarmTime INTEGER,
|
|
e5AlarmCliObject OCTET STRING,
|
|
e5AlarmSecObjectClass INTEGER,
|
|
e5AlarmSecObjectInstance1 INTEGER,
|
|
e5AlarmSecObjectInstance2 INTEGER,
|
|
e5AlarmSecObjectInstance3 INTEGER,
|
|
e5AlarmSecObjectInstance4 INTEGER,
|
|
e5AlarmSecObjectInstance5 INTEGER,
|
|
e5AlarmSecObjectInstance6 INTEGER,
|
|
e5AlarmSecObjectInstance7 INTEGER,
|
|
e5AlarmSecObjectInstance8 INTEGER
|
|
}
|
|
|
|
e5AlarmObjectClass OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dsl(1),
|
|
eqpt(2),
|
|
sys(3),
|
|
enet(4),
|
|
vop(5),
|
|
intf(6),
|
|
unknown(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Object Class for an alarm"
|
|
::= { e5AlarmEntry 1 }
|
|
|
|
e5AlarmObjectInstance1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Object instance for an alarm, level 1"
|
|
::= { e5AlarmEntry 2 }
|
|
|
|
e5AlarmObjectInstance2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Object instance for an alarm, level 2"
|
|
::= { e5AlarmEntry 3 }
|
|
|
|
e5AlarmObjectInstance3 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Object instance for an alarm, level 3"
|
|
::= { e5AlarmEntry 4 }
|
|
|
|
e5AlarmObjectInstance4 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Object instance for an alarm, level 4"
|
|
::= { e5AlarmEntry 5 }
|
|
|
|
e5AlarmObjectInstance5 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Object instance for an alarm, level 5"
|
|
::= { e5AlarmEntry 6 }
|
|
|
|
e5AlarmObjectInstance6 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Object instance for an alarm, level 6"
|
|
::= { e5AlarmEntry 7 }
|
|
|
|
e5AlarmObjectInstance7 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Object instance for an alarm, level 7"
|
|
::= { e5AlarmEntry 8 }
|
|
|
|
e5AlarmObjectInstance8 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Object instance for an alarm, level 8"
|
|
::= { e5AlarmEntry 9 }
|
|
|
|
e5AlarmType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Unique type for an alarm"
|
|
::= { e5AlarmEntry 10 }
|
|
|
|
e5AlarmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
clear(0),
|
|
critical(1),
|
|
major(2),
|
|
minor(3),
|
|
warning(4),
|
|
unknown(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Severity of the alarm"
|
|
::= { e5AlarmEntry 11 }
|
|
|
|
e5AlarmTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..50))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Timestamp indicating the set/clear time of the alarm"
|
|
::= { e5AlarmEntry 12 }
|
|
|
|
e5AlarmServiceAffecting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes(1),
|
|
no(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicated the nature of the alarm i.e. service
|
|
affecting or not"
|
|
::= { e5AlarmEntry 13 }
|
|
|
|
e5AlarmLocationInfo OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nearEnd(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { e5AlarmEntry 14 }
|
|
|
|
e5AlarmText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Alarm description"
|
|
::= { e5AlarmEntry 15 }
|
|
|
|
e5AlarmTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "UTC time"
|
|
::= { e5AlarmEntry 16 }
|
|
|
|
e5AlarmCliObject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The short CLI name for the object class and instance"
|
|
::= { e5AlarmEntry 17 }
|
|
|
|
e5AlarmSecObjectClass OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Secondary Object Class for an alarm"
|
|
::= { e5AlarmEntry 18 }
|
|
|
|
e5AlarmSecObjectInstance1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Secondary object instance for an alarm, level 1"
|
|
::= { e5AlarmEntry 19 }
|
|
|
|
e5AlarmSecObjectInstance2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Secondary object instance for an alarm, level 2"
|
|
::= { e5AlarmEntry 20 }
|
|
|
|
e5AlarmSecObjectInstance3 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Secondary object instance for an alarm, level 3"
|
|
::= { e5AlarmEntry 21 }
|
|
|
|
e5AlarmSecObjectInstance4 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Secondary object instance for an alarm, level 4"
|
|
::= { e5AlarmEntry 22 }
|
|
|
|
e5AlarmSecObjectInstance5 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Secondary object instance for an alarm, level 5"
|
|
::= { e5AlarmEntry 23 }
|
|
|
|
e5AlarmSecObjectInstance6 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Secondary object instance for an alarm, level 6"
|
|
::= { e5AlarmEntry 24 }
|
|
|
|
e5AlarmSecObjectInstance7 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Secondary object instance for an alarm, level 7"
|
|
::= { e5AlarmEntry 25 }
|
|
|
|
e5AlarmSecObjectInstance8 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Secondary object instance for an alarm, level 8"
|
|
::= { e5AlarmEntry 26 }
|
|
|
|
END |