mibs/MIBS/calix/E5-121-MIB
2023-12-05 12:25:34 +01:00

11343 lines
298 KiB
Plaintext

-- $Log: E5-121-MIB.mib $
-- Revision 1.80 2011/04/28 03:38:15 Alex.Shih
-- Revision 1.79 2011/03/10 09:37:49 swee
-- Remove supported in R5.x or later version info
-- Revision 1.78 2011/02/09 00:25:01 Alex.Shih
-- Revision 1.78 2011/02/09 00:09:51 Alex.Shih
-- Revision 1.77 2011/01/27 09:24:12 Alex.Shih
-- Revision 1.76 2011/01/26 12:10:03 ChunTing
-- Revision 1.75 2011/01/24 06:03:10 Alex.Shih
-- Revision 1.74 2011/01/07 07:32:04 cylien
-- fix compile error of mibble
-- Revision 1.73 2010/11/15 11:01:02 Alex.Shih
-- Revision 1.72 2010/11/12 02:58:58 cylien
-- Revision 1.71 2010/11/03 11:01:11 john
-- Revision 1.70 2010/11/03 02:23:04 cylien
-- Revision 1.69 2010/10/26 01:35:50 DavidGong
-- Revision 1.68 2010/10/25 10:08:15 Alex.Shih
-- Revision 1.67 2010/10/14 08:58:33 cylien
-- Revision 1.66 2010/09/30 08:17:58 Alex.Shih
-- Revision 1.65 2010/09/30 03:46:25 cylien
-- Revision 1.64 2010/09/29 02:29:28 cylien
-- Revision 1.63 2010/09/28 01:01:46 DavidGong
-- Revision 1.62 2010/09/23 07:59:18 cylien
-- Revision 1.61 2010/09/16 10:34:50 DavidGong
-- Revision 1.60 2010/09/08 07:02:21 Alex.Shih
-- Revision 1.59 2010/09/08 03:48:05 Alex.Shih
-- Revision 1.58 2010/08/27 09:03:48 John
-- Revision 1.57 2010/08/27 05:42:43 Alex.Shih
-- Revision 1.56 2010/08/13 11:48:09 cylien
-- Revision 1.55 2010/08/10 07:48:11 Alex.Shih
-- Revision 1.54 2010/07/19 05:36:01 John
-- Revision 1.53 2010/07/17 05:54:19 Alex.Shih
-- Revision 1.51 2010/07/09 11:03:19 John
-- Revision 1.50 2010/07/01 11:38:22 davidgong
-- Revision 1.49 2010/07/01 11:12:03 davidgong
-- Revision 1.48 2010/06/30 06:56:34 Alex.Shih
-- Revision 1.47 2010/06/29 07:58:06 Ives
-- Revision 1.46 2010/06/29 06:46:04 Alex.Shih
-- Revision 1.45 2010/06/29 06:00:49 Alex.Shih
-- Revision 1.44 2010/06/29 01:01:55 Alex.Shih
-- Revision 1.43 2010/06/28 17:05:05 John
-- Revision 1.41 2010/06/24 08:02:47 maverick
-- Revision 1.40 2010/06/24 07:47:34 davidgong
-- Revision 1.39 2010/06/24 05:28:16 davidgong
-- Revision 1.38 2010/06/15 14:28:37 maverick
-- Revision 1.37 2010/06/10 08:04:27 cylien
-- Revision 1.36 2010/06/10 02:49:55 cylien
-- Revision 1.35 2010/06/08 03:55:22 cylien
-- Revision 1.34 2010/06/07 00:55:31 davidgong
-- Revision 1.33 2010/06/04 11:56:58 Alex_Chang
-- Revision 1.32 2010/06/03 12:07:29 JeFF
-- Revision 1.31 2010/06/02 01:21:38 Alex.Shih
-- Revision 1.30 2010/05/21 03:57:38 maverick
-- Revision 1.29 2010/04/23 10:46:34 maverick
-- Revision 1.28 2009/11/26 13:06:58 maverick
-- add comment to obsoleted mib entries, mibble checked
-- Revision 1.27 2009/09/15 05:51:32 maverick
-- Revision 1.26 2009/09/15 02:48:22 maverick
-- Revision 1.25 2009/09/01 01:32:36 maverick
-- Revision 1.24 2009/07/27 08:16:56 niceguy
-- Revision 1.23 2009/07/21 10:52:52 maverick
-- Revision 1.21 2009/07/10 10:39:44 maverick
-- Revision 1.20 2009/06/26 11:01:57 John
-- Revision 1.19 2009/06/25 08:18:54 maverick
-- Revision 1.18 2009/06/25 02:47:26 niceguy
-- Revision 1.17 2009/06/10 02:26:39 John
-- Revision 1.16 2009/06/09 06:59:07 maverick
-- Revision 1.15 2009/05/27 09:19:31 niceguy
-- Revision 1.14 2009/05/25 08:53:38 maverick
-- Revision 1.13 2009/05/21 12:28:28 maverick
-- Revision 1.12 2009/05/21 08:14:42 lbr
-- Revision 1.11 2009/05/21 04:05:21 John
-- Revision 1.10 2009/05/20 13:04:21 maverick
-- Revision 1.9 2009/05/20 00:59:19 maverick
-- Revision 1.8 2009/04/30 10:10:31 niceguy
-- Revision 1.7 2009/04/29 05:51:22 niceguy
-- Revision 1.6 2009/04/21 02:58:22 niceguy
-- Revision 1.5 2009/03/06 12:32:03 maverick
-- Revision 1.4 2008/11/14 12:17:47 niceguy
-- Revision 1.3 2008/11/12 08:19:35 kenny
-- Revision 1.2 2008/09/26 10:45:37 niceguy
-- Revision 1.1 2008/09/18 01:50:27 niceguy
-- Initial revision
-- Revision 1.5 2008/08/21 10:55:19 kenny
-- Revision 1.4 2008/08/15 10:29:16 maverick
-- Revision 1.3 2008/08/05 06:35:53 maverick
-- Revision 1.2 2008/08/04 12:47:34 maverick
-- Revision 1.1 2008/07/11 09:36:15 maverick
-- Initial revision
-- Revision 1.7 2008/06/27 16:08:09 maverick
-- Revision 1.6 2008/06/23 08:54:10 kenny
-- Revision 1.5 2008/06/10 13:53:03 maverick
-- Revision 1.4 2008/05/30 14:12:22 maverick
-- Revision 1.3 2008/05/20 02:55:59 maverick
-- Revision 1.2 2008/05/13 02:03:13 maverick
-- Revision 1.6 2008/03/07 07:56:43 kenny
-- Revision 1.5 2007/12/14 10:00:11 niceguy
-- Revision 1.4 2007/12/14 02:42:41 niceguy
-- Revision 1.3 2007/12/06 02:03:04 kenny
-- Revision 1.2 2007/12/03 01:54:35 niceguy
-- Revision 1.1 2007/12/03 01:45:30 niceguy
-- Initial revision
-- Initial revision
E5-121-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises
FROM RFC1155-SMI
OBJECT-TYPE, Counter32, Gauge32, Unsigned32, Counter64, IpAddress, TimeTicks, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, PhysAddress, ifIndex
FROM RFC1213-MIB
RowStatus, TEXTUAL-CONVENTION
FROM SNMPv2-TC
VlanIndex, PortList, dot1qVlanIndex
FROM Q-BRIDGE-MIB
dot1dTrafficClass
FROM P-BRIDGE-MIB
MacAddress, Timeout, BridgeId, dot1dBasePort
FROM BRIDGE-MIB
dot1agCfmMdIndex, dot1agCfmMaIndex, dot1agCfmMepIdentifier
FROM IEEE8021-CFMD8-MIB;
calixNetworks OBJECT IDENTIFIER ::= { enterprises 6321 }
calixRegistrations OBJECT IDENTIFIER ::= { calixNetworks 1 }
calixProducts OBJECT IDENTIFIER ::= { calixRegistrations 2 }
e5x100 OBJECT IDENTIFIER ::= { calixProducts 3 }
e5x121 OBJECT IDENTIFIER ::= { e5x100 4 }
alarmconf OBJECT IDENTIFIER ::= { e5x121 2 }
diagnostic OBJECT IDENTIFIER ::= { e5x121 4 }
multicast OBJECT IDENTIFIER ::= { e5x121 7 }
port OBJECT IDENTIFIER ::= { e5x121 8 }
profile OBJECT IDENTIFIER ::= { e5x121 9 }
switch OBJECT IDENTIFIER ::= { e5x121 10 }
sys OBJECT IDENTIFIER ::= { e5x121 11 }
trap OBJECT IDENTIFIER ::= { e5x121 12 }
statistics OBJECT IDENTIFIER ::= { e5x121 13 }
clear OBJECT IDENTIFIER ::= { e5x121 14 }
-- 15 reserved for cluster
voip OBJECT IDENTIFIER ::= { e5x121 16 }
aesSeriesCommon OBJECT IDENTIFIER ::= { e5x121 97 } -- obsoleted since R2.0 by maverick
iesSeriesCommon OBJECT IDENTIFIER ::= { e5x121 98 }
accessSwitchCommonATM OBJECT IDENTIFIER ::= { e5x121 99 }
----------------------------------------
-- alarmconf
----------------------------------------
alarmOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manager sets the corresponding bit value to 1 to start the operation
and the agent clears the object to zero when the operation is successfully completed.
The various bit positions are:
BIT 1: clear
BIT 2: cutoff"
::= { alarmconf 1 }
-- Alarm Conf Table
alarmConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes alarm configuration."
::= { alarmconf 2 }
alarmConfEntry OBJECT-TYPE
SYNTAX AlarmConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in alarmConfTable."
INDEX { alarmConfId }
::= { alarmConfTable 1 }
AlarmConfEntry ::=
SEQUENCE {
alarmConfId INTEGER,
alarmConfFacility INTEGER,
alarmConfTarget INTEGER,
alarmConfSeverity INTEGER,
alarmConfClearable INTEGER
}
alarmConfId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
5000:vdslLine_up
5001:vdslLine_down
5002:vdsl_tca_lol
5003:vdsl_tca_lof
5004:vdsl_tca_los
5005:vdsl_tca_lop
5006:vdsl_tca_es
5007:vdsl_tca_ses
5008:vdsl_tca_uas
5009:xd_xtuc_loftrap
5010:xd_xtuc_lostrap
5011:xd_xtur_loftrap
5012:xd_xtur_lostrap
5013:xd_xtur_lprtrap
5014:ad_dhcp_rt_full
5015:ad_dhcp_dm_conflict
5016:ad_dhcp_entry_full
5017:ad_dhcp_ip_dup
5018:ad_dhcp_mac_dup
10000:eqptVol_err
10001:eqptEqpttemp_err
10002:eqptFan_err
10003:eqptHw_rtc_fail
10004:eqptHw_mon_fail
10005:eqptCold_start
10006:eqptWarm_start
10007:eqptAlm_input
10008:voip_battery_fail
10009:voip_clock_fail
10010:voip_ringer_fault
10011:eqptAlm_input2
10012:eqptAlm_input3
15000:sysReboot
15001:sysAco
15002:sysAlm_clear
15003:sysLogin_fail
15004:sysAnti_spoofing
15005:sysAlm_svrty_change
15006:sysHost_terminate
20000:enetUp
20001:enetDown
25000:voip_temp_error
25001:voip_dc_power_fail
25002:voip_ac_power_fail
25003:voip_ring_timer_fail
25004:voip_ring_rsrce_fail
25006:voip_dhcp_clt_fail
25007:voip_call_setup_failed
25008:voip_call_threshold_violate
30000:cfmError
"
::= { alarmConfEntry 1 }
alarmConfFacility OBJECT-TYPE
SYNTAX INTEGER {
local1(1),
local2(2),
local3(3),
local4(4),
local5(5),
local6(6),
local7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm facility."
::= { alarmConfEntry 2 }
alarmConfTarget OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination which alarms are reported to. Set the bit to 1 to enable the target.
BIT 1: snmp trap
BIT 2: syslog"
::= { alarmConfEntry 3 }
alarmConfSeverity OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
major(2),
minor(3),
info(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm severity"
::= { alarmConfEntry 4 }
alarmConfClearable OBJECT-TYPE
SYNTAX INTEGER {
clearable(1),
unclearable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the object to one indicates that the alarm is to be cleared when user submits alarm clear."
::= { alarmConfEntry 5 }
-- Alarm Current Table
alarmCurrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmCurrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes current alarm information."
::= { alarmconf 3 }
alarmCurrEntry OBJECT-TYPE
SYNTAX AlarmCurrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in alarmCurrTable."
INDEX { alarmCurrIndex }
::= { alarmCurrTable 1 }
AlarmCurrEntry ::=
SEQUENCE {
alarmCurrIndex INTEGER,
alarmCurrOccurTime TimeTicks,
alarmCurrTrapOid OBJECT IDENTIFIER,
alarmCurrParam1 INTEGER,
alarmCurrParam2 INTEGER,
alarmCurrParam3 INTEGER,
alarmCurrParam4 INTEGER,
alarmCurrParam5 INTEGER,
alarmCurrParam6 INTEGER,
alarmCurrParam7 INTEGER,
alarmCurrParam8 INTEGER,
alarmCurrTimeDescr DisplayString,
alarmCurrSeverity INTEGER,
alarmCurrDescr DisplayString
}
alarmCurrIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the alarm."
::= { alarmCurrEntry 1 }
alarmCurrOccurTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm occurence time (in hundredths of a second) since the system was last re-initialized."
::= { alarmCurrEntry 2 }
alarmCurrTrapOid OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Trap OID of the alarm."
::= { alarmCurrEntry 3 }
alarmCurrParam1 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 1st parameter of the alarm."
::= { alarmCurrEntry 4 }
alarmCurrParam2 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 2nd parameter of the alarm."
::= { alarmCurrEntry 5 }
alarmCurrParam3 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 3rd parameter of the alarm."
::= { alarmCurrEntry 6 }
alarmCurrParam4 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 4th parameter of the alarm."
::= { alarmCurrEntry 7 }
alarmCurrParam5 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 5th parameter of the alarm."
::= { alarmCurrEntry 8 }
alarmCurrParam6 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 6th parameter of the alarm."
::= { alarmCurrEntry 9 }
alarmCurrParam7 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 7th parameter of the alarm."
::= { alarmCurrEntry 10 }
alarmCurrParam8 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 8th parameter of the alarm."
::= { alarmCurrEntry 11 }
alarmCurrTimeDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The string representation of occurence time (YYYY/MM/DD HH:MM:SS)."
::= { alarmCurrEntry 12 }
alarmCurrSeverity OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
major(2),
minor(3),
info(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm."
::= { alarmCurrEntry 13 }
alarmCurrDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of the alarm."
::= { alarmCurrEntry 14 }
-- Alarm Severity Port Table
alarmSeverityPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmSeverityPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes the configuration of alarm reporting severity threshold for each port."
::= { alarmconf 4 }
alarmSeverityPortEntry OBJECT-TYPE
SYNTAX AlarmSeverityPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in alarmSeverityPortTable."
INDEX { ifIndex }
::= { alarmSeverityPortTable 1 }
AlarmSeverityPortEntry ::=
SEQUENCE {
severityThresh INTEGER
}
severityThresh OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
major(2),
minor(3),
info(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum alarm severity that is reported."
::= { alarmSeverityPortEntry 1 }
----------------------------------------
-- diagnostic
----------------------------------------
selt OBJECT IDENTIFIER ::= { diagnostic 3 }
ldm OBJECT IDENTIFIER ::= { diagnostic 4 }
mlt OBJECT IDENTIFIER ::= { diagnostic 5 }
--------------------
-- selt
--------------------
seltTarget OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IfIndex of the port which would be performed single end loopback test."
::= { selt 1 }
seltOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manager sets the object to 1 to start the selt
and the agent clears the object to zero when selt is successfully completed."
::= { selt 2 }
seltStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status description of the selt result."
::= { selt 3 }
seltCableType OBJECT-TYPE
SYNTAX INTEGER {
awg24(1),
awg26(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cable type that selt result indicates."
::= { selt 4 }
seltLoopEstimateLengthFt OBJECT-TYPE
SYNTAX INTEGER
UNITS "feet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The estimated loop length that selt result indicates."
::= { selt 5 }
seltLoopEstimateLengthMeter OBJECT-TYPE
SYNTAX INTEGER
UNITS "meter"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The estimated loop length that selt result indicates."
::= { selt 6 }
--------------------
-- ldm
--------------------
ldmTarget OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IfIndex of the port which would be performed ldm test."
::= { ldm 1 }
ldmOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manager sets the object to 1 to start the ldm test
and the agent clears the object to zero when ldm test is successfully completed."
::= { ldm 2 }
ldmStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status description of ldm test result."
::= { ldm 3 }
ldmXtucLoopAttenuation OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop Attenuation."
::= { ldm 4 }
ldmXtucSignalAttenuation OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal Attenuation."
::= { ldm 5 }
ldmXtucSignalMargin OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal Margin."
::= { ldm 6 }
ldmXtucAggregateTxPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual Aggregate Transmit Power."
::= { ldm 7 }
ldmXtucAttainableBitRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bits per second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attainable Bit Rate."
::= { ldm 8 }
ldmXturLoopAttenuation OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loop Attenuation."
::= { ldm 9 }
ldmXturSignalAttenuation OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal Attenuation."
::= { ldm 10 }
ldmXturSignalMargin OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal Margin."
::= { ldm 11 }
ldmXturAggregateTxPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual Aggregate Transmit Power."
::= { ldm 12 }
ldmXturAttainableBitRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bits per second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attainable Bit Rate."
::= { ldm 13 }
ldmXtucNumOfSubcarriersPerPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of subcarriers per port for ATU-C."
::= { ldm 14 }
ldmXturNumOfSubcarriersPerPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of subcarriers per port for ATU-R."
::= { ldm 15 }
ldmXtucHlinScale OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Scale of Hlin."
::= { ldm 16 }
ldmXtucHlinReal1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides real part of Hlin for the first 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 17 }
ldmXtucHlinReal2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides real part of Hlin for the last 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 18 }
ldmXtucHlinImage1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides image part of Hlin for the first 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 19 }
ldmXtucHlinImage2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides image part of Hlin for the last 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 20 }
ldmXtucHlog1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Hlog for the first 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 21 }
ldmXtucHlog2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Hlog for the last 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 22 }
ldmXtucQln1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides QLN for the first 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 23 }
ldmXtucQln2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides QLN for the last 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 24 }
ldmXtucSnr1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides SNR for the first 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 25 }
ldmXtucSnr2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides SNR for the last 256 subcarriers.
Each subcarrier takes two octets to store the value."
::= { ldm 26 }
ldmXturHlinScale OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Scale of Hlin."
::= { ldm 27 }
ldmXturHlinReal OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Real part of Hlin. Each subcarrier takes two octets to store the value."
::= { ldm 28 }
ldmXturHlinImage OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Image part of Hlin. Each subcarrier takes two octets to store the value."
::= { ldm 29 }
ldmXturHlog OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hlog of subcarrier. Each subcarrier takes two octets to store the value."
::= { ldm 30 }
ldmXturQln OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"QLN of subcarrier. Each subcarrier takes two octets to store the value."
::= { ldm 31 }
ldmXturSnr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNR of subcarrier. Each subcarrier takes two octets to store the value."
::= { ldm 32 }
ldmXtucHlogGroupFactor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Hlog group factor of ATU-C."
::= { ldm 33 }
ldmXtucQlnGroupFactor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Qln group factor of ATU-C."
::= { ldm 34 }
ldmXtucSnrGroupFactor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Snr group factor of ATU-C."
::= { ldm 35 }
ldmXturHlogGroupFactor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Hlog group factor of ATU-R."
::= { ldm 36 }
ldmXturQlnGroupFactor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Qln group factor of ATU-R."
::= { ldm 37 }
ldmXturSnrGroupFactor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Snr group factor of ATU-R."
::= { ldm 38 }
--------------------
-- mlt
--------------------
mltTarget OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IfIndex of the port which would be performed Metallic Link Test."
::= { mlt 1 }
mltOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manager sets the object to 1 to start the mlt
and the agent clears the object to zero when mlt is successfully completed."
::= { mlt 2 }
mltOption OBJECT-TYPE
SYNTAX INTEGER {
all(1),
vac(2),
vdc(3),
rload(4),
riso(5),
cap(6),
ren(7),
ring(8),
metering(9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"all : test all items
vac: test AC voltage
vdc: test DC voltage
rload: test load resistance
riso: test isolation resistance
cap: test capacitor
ren: test REN value
ring: test ring voltage
metering: test metering voltage"
::= { mlt 3 }
mltForce OBJECT-TYPE
SYNTAX INTEGER {
force(1),
notForce(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Force test even the port is in use."
::= { mlt 4 }
mltResult OBJECT IDENTIFIER ::= { mlt 5 }
mltVacTip OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 rms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 1 }
mltVacRing OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 rms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 2 }
mltVacDiff OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 rms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 3 }
mltVdcTip OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 volt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 4 }
mltVdcRing OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 volt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 5 }
mltVdcDiff OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 volt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 6 }
mltRLoop OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 7 }
mltRtg OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 8 }
mltRrg OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 9 }
mltRtr OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 ohm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 10 }
mltCtg OBJECT-TYPE
SYNTAX INTEGER
UNITS "10^-9 F"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 11 }
mltCrg OBJECT-TYPE
SYNTAX INTEGER
UNITS "10^-9 F"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 12 }
mltCtr OBJECT-TYPE
SYNTAX INTEGER
UNITS "10^-9 F"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 13 }
mltRen OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 ren"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 14 }
mltVRing OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 rms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 15 }
mltVMetering OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1 vpeak"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 16 }
mltDialToneDetected OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 17 }
mltDetectedDtmfCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 18 }
mltDialToneDelay OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.001 sec"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { mltResult 19 }
-- mlt relay table
mltRelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF MltRelayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Perform specified MLT relay function, or turn off
MLT relay function in specified subscriber."
::= { mlt 6 }
mltRelayEntry OBJECT-TYPE
SYNTAX MltRelayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of mltRelayTable."
INDEX { ifIndex }
::= { mltRelayTable 1 }
MltRelayEntry ::=
SEQUENCE {
mltRelaySet INTEGER
}
mltRelaySet OBJECT-TYPE
SYNTAX INTEGER {
in(1),
out(2),
both(3),
off(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"By default, relay function is turned off."
::= { mltRelayEntry 1 }
----------------------------------------
-- multicast
----------------------------------------
-- Obsoleted in calix MRD20 since Revision 1.20 at 2009/06/25 by niceguy
-- Object mcastBandwidth, igmpCount below is kept for R1.x below. Not used for R2.x and above.
mcastBandwidth OBJECT IDENTIFIER ::= { multicast 4 }
igmpCount OBJECT IDENTIFIER ::= { multicast 5 }
mvlan OBJECT IDENTIFIER ::= { multicast 6 }
queryVid OBJECT IDENTIFIER ::= { multicast 7 }
igmpTimer OBJECT IDENTIFIER ::= { multicast 11 }
auditQuery OBJECT IDENTIFIER ::= { multicast 12 }
igmpProfile OBJECT IDENTIFIER ::= { multicast 13 }
igmpEnable OBJECT-TYPE
SYNTAX INTEGER {
enableProxy(1),
enableSnooping(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable IGMP protocol."
::= { multicast 1 }
igmpVersion OBJECT-TYPE
SYNTAX INTEGER {
v2(1),
v3(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting IGMP version."
::= { multicast 9 }
igmpLeaveMode OBJECT-TYPE
SYNTAX INTEGER {
immediateLeave(1),
lastMemberQuery(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure IGMP leave message handling mode."
::= { multicast 10 }
--------------------
-- bandwidth
--------------------
-- removed in calix MRD20
-- To support multiple version of E5-1xx (Currently R1.x and R2.x), we keep all those useful entries in the MIB
mcastDefaultBandwidth OBJECT-TYPE
SYNTAX INTEGER (1..100000)
UNITS "Kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default bandwidth requirement for a multicast channel."
::= { mcastBandwidth 1 }
maxNumOfMcastBw OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of row entries that user can create in mcastBwTable."
::= { mcastBandwidth 2 }
-- mcastBwTable
mcastBwTable OBJECT-TYPE
SYNTAX SEQUENCE OF McastBwEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines bandwidth budget for a range of multicast IP channels."
::= { mcastBandwidth 3 }
mcastBwEntry OBJECT-TYPE
SYNTAX McastBwEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of mcastBwTable."
INDEX { mcastBwIndex, mcastBwStartIp, mcastBwEndIp }
::= { mcastBwTable 1 }
McastBwEntry ::=
SEQUENCE {
mcastBwIndex INTEGER,
mcastBwStartIp IpAddress,
mcastBwEndIp IpAddress,
mcastBwBandwidth INTEGER,
mcastBwRowStatus RowStatus
}
mcastBwIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index which specify the entry."
::= { mcastBwEntry 1 }
mcastBwStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The start multicast IP of the bandwidth control range."
::= { mcastBwEntry 2 }
mcastBwEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The end multicast IP of the bandwidth control range."
::= { mcastBwEntry 3 }
mcastBwBandwidth OBJECT-TYPE
SYNTAX INTEGER
UNITS "Kbps"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The bandwidth budget for the multicast IP channels."
::= { mcastBwEntry 4 }
mcastBwRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of the entry."
::= { mcastBwEntry 5 }
-- mcastBwPortTable
mcastBwPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF McastBwPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table specify the multicast bandwidth control of the port."
::= { mcastBandwidth 4 }
mcastBwPortEntry OBJECT-TYPE
SYNTAX McastBwPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of mcastBwPortTable."
INDEX { ifIndex }
::= { mcastBwPortTable 1 }
McastBwPortEntry ::=
SEQUENCE {
mcastBwPortEnable INTEGER,
mcastBwPortBandwidth INTEGER
}
mcastBwPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable multicast bandwidth control for a port."
::= { mcastBwPortEntry 1 }
mcastBwPortBandwidth OBJECT-TYPE
SYNTAX INTEGER
UNITS "Kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set bandwidth threshold for a port."
::= { mcastBwPortEntry 2 }
--------------------
-- igmpCount
--------------------
-- removed in calix MRD20
-- To support multiple version of E5-1xx (Currently R1.x and R2.x), we keep all those useful entries in the MIB
igmpCountPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpCountPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table specify the IGMP count limiting of the port."
::= { igmpCount 1 }
igmpCountPortEntry OBJECT-TYPE
SYNTAX IgmpCountPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of igmpCountPortTable."
INDEX { ifIndex }
::= { igmpCountPortTable 1 }
IgmpCountPortEntry ::=
SEQUENCE {
igmpCountPortEnable INTEGER,
igmpCountPortLimit INTEGER
}
igmpCountPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable IGMP count limiting for a port."
::= { igmpCountPortEntry 1 }
igmpCountPortLimit OBJECT-TYPE
SYNTAX INTEGER (0..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum allowed IGMP report count for a port."
::= { igmpCountPortEntry 2 }
--------------------
-- mvlan
--------------------
maxNumOfMvlan OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of row entries that user can create in mvlanTable."
::= { mvlan 1 }
-- mvlanTable
mvlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF MvlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing static configuration information for
each multicast VLAN configured into the device."
::= { mvlan 2 }
mvlanEntry OBJECT-TYPE
SYNTAX MvlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of mvlanTable."
INDEX { mvlanIndex }
::= { mvlanTable 1 }
MvlanEntry ::=
SEQUENCE {
mvlanIndex VlanIndex,
mvlanName DisplayString,
mvlanEgressPorts PortList,
mvlanUntaggedPorts PortList,
mvlanRowStatus RowStatus
}
mvlanIndex OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN-ID refering to this VLAN."
::= { mvlanEntry 1 }
mvlanName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An administratively assigned string, which may be used to identify the VLAN."
::= { mvlanEntry 2 }
mvlanEgressPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of ports which are permanently assigned to the
egress list for this multicast VLAN."
::= { mvlanEntry 3 }
mvlanUntaggedPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of ports which should transmit egress packets
for this multicast VLAN as untagged."
::= { mvlanEntry 4 }
mvlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the status of this entry."
::= { mvlanEntry 5 }
-- mvlanTranslateTable
mvlanTranslateTable OBJECT-TYPE
SYNTAX SEQUENCE OF MvlanTranslateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains multicast to VLAN translation."
::= { mvlan 3 }
mvlanTranslateEntry OBJECT-TYPE
SYNTAX MvlanTranslateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of mvlanTranslateTable."
INDEX { dot1qVlanIndex, mvlanTranslateIndex }
::= { mvlanTranslateTable 1 }
MvlanTranslateEntry ::=
SEQUENCE {
mvlanTranslateIndex INTEGER,
mvlanTranslateStartIp IpAddress,
mvlanTranslateEndIp IpAddress
}
mvlanTranslateIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index which specif the entry."
::= { mvlanTranslateEntry 1 }
mvlanTranslateStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The start IP of the multicast VLAN translation."
::= { mvlanTranslateEntry 2 }
mvlanTranslateEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The end IP of the multicast VLAN translation."
::= { mvlanTranslateEntry 3 }
--------------------
-- queryVid
--------------------
maxNumOfQryVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of row entries that user can create in qryVidConfTable."
::= { queryVid 1 }
-- qryVidConfTable
qryVidConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QryVidConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines statically set VLANs used for response IGMP report."
::= { queryVid 2 }
qryVidConfEntry OBJECT-TYPE
SYNTAX QryVidConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in qryVidConfTable."
INDEX { qryVid }
::= { qryVidConfTable 1 }
QryVidConfEntry ::=
SEQUENCE {
qryVid INTEGER,
qryVidRowStatus RowStatus
}
qryVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN ID."
::= { qryVidConfEntry 1 }
qryVidRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the status of this entry."
::= { qryVidConfEntry 2 }
-- qryVidStatusTable
qryVidStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF QryVidStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows statically set or dynamically learned VLANs used for response IGMP report."
::= { queryVid 3 }
qryVidStatusEntry OBJECT-TYPE
SYNTAX QryVidStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in qryVidStatusTable."
INDEX { qryVid }
::= { qryVidStatusTable 1 }
QryVidStatusEntry ::=
SEQUENCE {
qryVidType INTEGER
}
qryVidType OBJECT-TYPE
SYNTAX INTEGER {
static(1),
dynamic(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN type."
::= { qryVidStatusEntry 1 }
--------------------
-- igmpTimer
--------------------
igmpQryInterval OBJECT-TYPE
SYNTAX INTEGER (10..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IGMP query interval, 10~1000 in seconds."
::= { igmpTimer 1 }
igmpRobust OBJECT-TYPE
SYNTAX INTEGER (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IGMP query Robustness, 1~5."
::= { igmpTimer 2 }
igmpQryRespInterval OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IGMP query response interval, 1~100 in 100 milliseconds."
::= { igmpTimer 3 }
igmpLastMemQryInterval OBJECT-TYPE
SYNTAX INTEGER (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IGMP Last Member Query interval, 1~5 in 100 milliseconds."
::= { igmpTimer 4 }
igmpLastMemQryRobust OBJECT-TYPE
SYNTAX INTEGER (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set Last Member Query Robustness, 1~5."
::= { igmpTimer 5 }
--------------------
-- auditQuery
--------------------
auditQryEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable IGMP audit query."
::= { auditQuery 1 }
auditQryInterval OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IGMP Audit Query Interval, 1~4 in 100 milliseconds."
::= { auditQuery 2 }
auditQryRobust OBJECT-TYPE
SYNTAX INTEGER (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IGMP Audit Query Robustness, 1~5."
::= { auditQuery 3 }
--------------------
-- igmpProfile
--------------------
maxNumberOfIgmpProfiles OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of IGMP profiles in the system."
::= { igmpProfile 1 }
igmpProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains IGMP Profiles."
::= { igmpProfile 2 }
igmpProfileEntry OBJECT-TYPE
SYNTAX IgmpProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of IGMP Profile table."
INDEX {IMPLIED igmpProfileName }
::= { igmpProfileTable 1 }
IgmpProfileEntry ::=
SEQUENCE {
igmpProfileName DisplayString,
igmpProfileEnable INTEGER,
igmpProfileMaxGroup INTEGER,
igmpProfileRowStatus RowStatus
}
igmpProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IGMP Profile name."
::= { igmpProfileEntry 1 }
igmpProfileEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable IGMP Profile."
::= { igmpProfileEntry 2 }
igmpProfileMaxGroup OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set maximum allowed multicast group, 1~64."
::= { igmpProfileEntry 3 }
igmpProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of the IGMP Profile entry."
::= { igmpProfileEntry 4 }
igmpFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains IGMP Filters."
::= { igmpProfile 3 }
igmpFilterEntry OBJECT-TYPE
SYNTAX IgmpFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of IGMP Filter table."
INDEX { igmpProfileName, igmpFilterIndex }
::= { igmpFilterTable 1 }
IgmpFilterEntry ::=
SEQUENCE {
igmpFilterIndex INTEGER,
igmpFilterStartIp IpAddress,
igmpFilterEndIp IpAddress
}
igmpFilterIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index which specifies the filter rule."
::= { igmpFilterEntry 1 }
igmpFilterStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The start IP of the filter rule."
::= { igmpFilterEntry 2 }
igmpFilterEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The end IP of the filter rule."
::= { igmpFilterEntry 3 }
igmpProfilePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpProfilePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table specifies the IGMP Profile of the port."
::= { igmpProfile 4 }
igmpProfilePortEntry OBJECT-TYPE
SYNTAX IgmpProfilePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in igmpProfilePortTable."
INDEX { ifIndex }
::= { igmpProfilePortTable 1 }
IgmpProfilePortEntry ::=
SEQUENCE {
igmpProfilePortProfile OCTET STRING
}
igmpProfilePortProfile OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IGMP Profile of the port."
::= { igmpProfilePortEntry 1 }
----------------------------------------
-- port
----------------------------------------
-- Since we define it latter, mark the definition here
-- subrPortTable OBJECT IDENTIFIER ::= { port 1 }
-- adslPort OBJECT IDENTIFIER ::= { port 2 }
vdslPort OBJECT IDENTIFIER ::= { port 3 }
pvc OBJECT IDENTIFIER ::= { port 4 }
-- ppvc OBJECT IDENTIFIER ::= { port 5 }
rpvc OBJECT IDENTIFIER ::= { port 8 }
-- Since we define it latter, mark the definition here
-- dsBcastDisableTable OBJECT IDENTIFIER ::= { port 9 }
paepvc OBJECT IDENTIFIER ::= { port 10 }
tlspvc OBJECT IDENTIFIER ::= { port 11 }
-- ipbpvc OBJECT IDENTIFIER ::= { port 12 }
dtpvc OBJECT IDENTIFIER ::= { port 13 }
voipPort OBJECT IDENTIFIER ::= { port 14 }
snrMgn OBJECT IDENTIFIER ::= { port 15 }
dslRate OBJECT IDENTIFIER ::= { port 16 }
-- G.bond start from 51
gbond OBJECT IDENTIFIER ::= { port 51 }
-- Subscriber Port Table
subrPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF SubrPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes subscriber attributes for the port."
::= { port 1 }
subrPortEntry OBJECT-TYPE
SYNTAX SubrPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in subrPortTable."
INDEX { ifIndex }
::= { subrPortTable 1 }
SubrPortEntry ::=
SEQUENCE {
subrPortName DisplayString,
subrPortTel DisplayString
}
subrPortName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the subscriber."
::= { subrPortEntry 1 }
subrPortTel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Telephone number of the subscriber."
::= { subrPortEntry 2 }
--------------------
-- vdslPort
--------------------
-- VDSL Line Table
vdslLineConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslLineConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes common attributes describing the VDSL line.
This table is supported by R2.00 and later versions."
::= { vdslPort 1 }
vdslLineConfEntry OBJECT-TYPE
SYNTAX VdslLineConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslLineConfTable."
INDEX { ifIndex }
::= { vdslLineConfTable 1 }
VdslLineConfEntry ::=
SEQUENCE {
vdslLineConfUpbo INTEGER,
vdslLineConfVdslProfile INTEGER,
-- vdslLineConfFrequencyPlan INTEGER,
vdslLineConfRfiBand INTEGER,
vdslLineConfIpqosProfile DisplayString,
vdslLineConfVturInp INTEGER,
vdslLineConfVtucInp INTEGER,
vdslLineConfOptionMask INTEGER,
vdslLineConfUpboForceLength INTEGER,
vdslLineConfPsdShape INTEGER,
vdslLineConfDpbo INTEGER,
vdslLineConfDpboParamEsel INTEGER,
vdslLineConfDpboParamEscma INTEGER,
vdslLineConfDpboParamEscmb INTEGER,
vdslLineConfDpboParamEscmc INTEGER,
vdslLineConfDpboParamMus INTEGER,
vdslLineConfDpboParamFmin INTEGER,
vdslLineConfDpboParamFmax INTEGER,
vdslLineConfDpboParamPsdId INTEGER
-- vdslLineConfPMask INTEGER
}
vdslLineConfUpbo OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable upstream power backoff control."
::= { vdslLineConfEntry 1 }
vdslLineConfVdslProfile OBJECT-TYPE
SYNTAX INTEGER {
vdsl8a(1),
vdsl8b(2),
vdsl8c(3),
vdsl8d(4),
vdsl12a(5),
vdsl12b(6),
vdsl17a(7),
auto(8),
adsl2plus(9),
vdsl2(10),
gdmt(11),
glite(12),
adsl2(13),
t1413(14),
vdsl2adsl2(15),
vdsl2gdmt(16),
vdsl2glite(17),
vdsl2t1413(18)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set VDSL profile."
::= { vdslLineConfEntry 2 }
-- vdslLineConfFrequencyPlan OBJECT-TYPE
-- SYNTAX INTEGER {
-- plan997(1),
-- plan998(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Set VDSL frequency plan."
-- ::= { vdslLineConfEntry 3 }
vdslLineConfRfiBand OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
ansi(2),
etsi(3),
custom(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set VDSL customized RFI configuration.
disable: not apply RFI notch to port
ansi: use pre-defined ANSI RFI notch
etsi: use pre-defined ETSI notch
custom: user needs to define customized RFI notch band through vdslRfiCustomTable"
::= { vdslLineConfEntry 4 }
vdslLineConfIpqosProfile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { vdslLineConfEntry 5 }
vdslLineConfVturInp OBJECT-TYPE
SYNTAX INTEGER (0..160)
UNITS "0.1 DTM symbol"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VTUR minimum INP value"
::= { vdslLineConfEntry 6 }
vdslLineConfVtucInp OBJECT-TYPE
SYNTAX INTEGER (0..160)
UNITS "0.1 DTM symbol"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VTUC mimimum INT value"
::= { vdslLineConfEntry 7 }
vdslLineConfOptionMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Bit1: disable Trellis coding in ADSL mode
Bit2: disable Reed-Solomon coding for ADSL
Bit3: disable upstream bitswaps
Bit4: disable downstream bitwaps
Bit5: disable upstream 1-bit constellation support
Bit6: disable the transmit windowing in ADSL2+ mode
Bit7: disable S=0.5 support in G.dmt
Bit8: reserved
Bit9: enable nitro
Bit10: enable ADSL2 Annex L
Bit11: enable ADSL2+ Annex M
Bit12: enable US PTM optimization
Bit13: enable DS PTM optimization
Bit14: enable US PHYR
Bit15: enable DS PHYR"
::= { vdslLineConfEntry 8 }
vdslLineConfUpboForceLength OBJECT-TYPE
SYNTAX INTEGER (-5..1270)
UNITS "0.1dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"-1 means max(kl0_CO,kl0_CPE).
-2 means min(kl0_CO,kl0_CPE).
-3 means kl0_CO.
-4 means kl0_CPE.
-5 means kl0_CPE + delta as calculated from.
"
::= { vdslLineConfEntry 9 }
vdslLineConfPsdShape OBJECT-TYPE
SYNTAX INTEGER {
vdsl2aNus0(1),
vdsl2aEu32(2),
vdsl2aEu36(3),
vdsl2aEu40(4),
vdsl2aEu44(5),
vdsl2aEu48(6),
vdsl2aEu52(7),
vdsl2aEu56(8),
vdsl2aEu60(9),
vdsl2aEu64(10),
vdsl2aEu128(11),
vdsl1fttexAnsiM1(12),
vdsl1fttexAnsiM2(13),
vdsl1fttcabAnsiM1(14),
vdsl1fttcabAnsiM2(15),
vdsl1fttexAnsiM1E(16),
vdsl1fttexAnsiM2E(17),
vdslFttcabAnsiM1E(18),
vdslFttcabAnsiM2E(19),
vdsl2aCt(20),
vdsl2b8x1(21),
vdsl2b8x2(22),
vdsl2b8x3(23),
vdsl2b8x4(24),
vdsl2b8x5(25),
vdsl2b8x6(26),
vdsl2b8x7(27),
vdsl2b8x8(28),
vdsl2b8x9(29),
vdsl2b8x10(30),
vdsl2b8x11(31),
vdsl2b8x12(32),
vdsl2b8x13(33),
vdsl2b8x14(34),
vdsl2b8x15(35),
vdsl2b8x16(36),
vdsl2b7x1(37),
vdsl2b7x2(38),
vdsl2b7x3(39),
vdsl2b7x4(40),
vdsl2b7x5(41),
vdsl2b7x6(42),
vdsl2b7x7(43),
vdsl2b7x8(44),
vdsl2b7x9(45),
vdsl2b7x10(46),
vdsl2btAnfp(47),
vdsl2c138b(48),
vdsl2c276b(49),
vdsl2c138co(50),
vdsl2c276co(51),
vdsl2cTcmisdn(52),
vdsl1QAMCompatible(53)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PSD mask type"
::= { vdslLineConfEntry 10 }
vdslLineConfDpbo OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DPBO"
::= { vdslLineConfEntry 11 }
vdslLineConfDpboParamEsel OBJECT-TYPE
SYNTAX INTEGER (0..511)
UNITS "0.5dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO ESEL parameter"
::= { vdslLineConfEntry 12 }
vdslLineConfDpboParamEscma OBJECT-TYPE
SYNTAX INTEGER (0..640)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO ESCMA parameter -1~1.5 in step of 1/256."
::= { vdslLineConfEntry 13 }
vdslLineConfDpboParamEscmb OBJECT-TYPE
SYNTAX INTEGER (0..640)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO ESCMB parameter -1~1.5 in step of 1/256."
::= { vdslLineConfEntry 14 }
vdslLineConfDpboParamEscmc OBJECT-TYPE
SYNTAX INTEGER (0..640)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO ESCMC parameter -1~1.5 in step of 1/256."
::= { vdslLineConfEntry 15 }
vdslLineConfDpboParamMus OBJECT-TYPE
SYNTAX INTEGER (0..255)
UNITS "-0.5 dBm/Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO MUS parameter."
::= { vdslLineConfEntry 16 }
vdslLineConfDpboParamFmin OBJECT-TYPE
SYNTAX INTEGER (0..2048)
UNITS "4.3125kHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO FMIN parameter"
::= { vdslLineConfEntry 17 }
vdslLineConfDpboParamFmax OBJECT-TYPE
SYNTAX INTEGER (32..6956)
UNITS "4.3125kHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DPBO FMAX parameter"
::= { vdslLineConfEntry 18 }
vdslLineConfDpboParamPsdId OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
psdCo(1),
psdFlat(2),
psdCabAnsi(3),
psdCabEtsi(4),
psdExchEtsi(5),
psdExchAnsi(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Valid range for setting is 1~6."
::= { vdslLineConfEntry 19 }
-- vdslLineConfPMask OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "
-- Bit1: G.DMT (G.992.1)
-- Bit2: G.LITE (G.992.2)
-- Bit3: ADSL2 (G.992.3)
-- Bit5: ADSL2+ (G.992.5)
-- Bit6: ANSI T1.413
-- Bit8: G.993.2 VDSL profile 8a
-- Bit9: G.993.2 VDSL profile 8b
-- Bit10: G.993.2 VDSL profile 8c
-- Bit11: G.993.2 VDSL profile 8d
-- Bit12: G.993.2 VDSL profile 12a
-- Bit13: G.993.2 VDSL profile 12b
-- Bit14: G.993.2 VDSL profile 17a"
-- ::= { vdslLineConfEntry 20 }
vdslVlan OBJECT IDENTIFIER ::= { vdslPort 2 }
-- vdslPortConfTable
vdslPortConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslPortConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes common attributes describing the VDSL port.
This table is supported by R2.00 and later versions."
::= { vdslVlan 1 }
vdslPortConfEntry OBJECT-TYPE
SYNTAX VdslPortConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslPortConfTable."
INDEX { ifIndex }
::= { vdslPortConfTable 1 }
VdslPortConfEntry ::=
SEQUENCE {
-- vdslPortConfPvid VlanIndex,
-- vdslPortConfPriority INTEGER,
-- vdslPortConfAcceptableFrameType INTEGER,
vdslPortConfTlsEnable INTEGER,
vdslPortConfTlsVid VlanIndex,
vdslPortConfTlsPriority INTEGER,
vdslPortConfDtEnable INTEGER,
vdslPortConfDtSVid VlanIndex,
vdslPortConfDtSPriority INTEGER,
vdslPortConfDtCVid VlanIndex,
vdslPortConfDtCPriority INTEGER
}
-- vdslPortConfPvid OBJECT-TYPE
-- SYNTAX VlanIndex
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The PVID, the VLAN ID assigned to untagged frames or
-- Priority-Tagged frames received on this port."
-- ::= { vdslPortConfEntry 1 }
--
-- vdslPortConfPriority OBJECT-TYPE
-- SYNTAX INTEGER (0..7)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The default ingress User Priority for this port."
-- ::= { vdslPortConfEntry 2 }
--
-- vdslPortConfAcceptableFrameType OBJECT-TYPE
-- SYNTAX INTEGER {
-- admitAll(1),
-- admitOnlyVlanTagged(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "When this is admitOnlyVlanTagged(2) the device will
-- discard untagged frames or Priority-Tagged frames
-- received on this port. When admitAll(1), untagged
-- frames or Priority-Tagged frames received on this port
-- will be accepted and assigned to the PVID for this port"
-- ::= { vdslPortConfEntry 3 }
vdslPortConfTlsEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable the transparent LAN service."
::= { vdslPortConfEntry 4 }
vdslPortConfTlsVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The transparent LAN service s-tag VID."
::= { vdslPortConfEntry 5 }
vdslPortConfTlsPriority OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The transparent LAN service s-tag priority."
::= { vdslPortConfEntry 6 }
vdslPortConfDtEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable the Double Tagging service."
::= { vdslPortConfEntry 7 }
vdslPortConfDtSVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Double Tagging service s-tag VID."
::= { vdslPortConfEntry 8 }
vdslPortConfDtSPriority OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Double Tagging service s-tag priority."
::= { vdslPortConfEntry 9 }
vdslPortConfDtCVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Double Tagging service c-tag VID."
::= { vdslPortConfEntry 10 }
vdslPortConfDtCPriority OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Double Tagging service c-tag priority."
::= { vdslPortConfEntry 11 }
-- vdslPortVlanTranslateTable
vdslPortVlanTranslateTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslPortVlanTranslateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains VLAN translation."
::= { vdslVlan 2 }
vdslPortVlanTranslateEntry OBJECT-TYPE
SYNTAX VdslPortVlanTranslateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslPortVlanTranslateTable."
INDEX { ifIndex , vdslPortVlanTranslateVpi , vdslPortVlanTranslateVci , vdslPortVlanTranslateCvid }
::= { vdslPortVlanTranslateTable 1 }
VdslPortVlanTranslateEntry ::=
SEQUENCE {
vdslPortVlanTranslateVpi INTEGER,
vdslPortVlanTranslateVci INTEGER,
vdslPortVlanTranslateCxvid VlanIndex,
vdslPortVlanTranslateCvid VlanIndex,
vdslPortVlanTranslateSvid VlanIndex,
vdslPortVlanTranslateDsonly INTEGER,
vdslPortVlanTranslateRowStatus RowStatus
}
vdslPortVlanTranslateVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the vtt."
::= { vdslPortVlanTranslateEntry 1 }
vdslPortVlanTranslateVci OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the vtt."
::= { vdslPortVlanTranslateEntry 2 }
vdslPortVlanTranslateCxvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CXVID of the vtt."
::= { vdslPortVlanTranslateEntry 3 }
vdslPortVlanTranslateCvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CVID of the vtt."
::= { vdslPortVlanTranslateEntry 4 }
vdslPortVlanTranslateSvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SVID of the vtt."
::= { vdslPortVlanTranslateEntry 5 }
vdslPortVlanTranslateDsonly OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Donwstream direction only of the vtt."
::= { vdslPortVlanTranslateEntry 6 }
vdslPortVlanTranslateRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { vdslPortVlanTranslateEntry 7 }
-- vdslPortVlanTable
-- vdslPortVlanTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF VdslPortVlanEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes common attributes describing the VDSL port.
-- This table is supported by R2.00 and later versions."
-- ::= { vdslVlan 2 }
--
-- vdslPortVlanEntry OBJECT-TYPE
-- SYNTAX VdslPortVlanEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry in vdslPortVlanTable."
-- INDEX { ifIndex, dot1qVlanIndex }
-- ::= { vdslPortVlanTable 1 }
--
-- VdslPortVlanEntry ::=
-- SEQUENCE {
-- vdslPortVlanReg INTEGER,
-- vdslPortVlanTag INTEGER,
-- vdslPortVlanRowStatus RowStatus
-- }
--
-- vdslPortVlanReg OBJECT-TYPE
-- SYNTAX INTEGER {
-- egress(1),
-- forbidden(2)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The port is egress or forbidden for this VLAN."
-- ::= { vdslPortVlanEntry 1 }
--
-- vdslPortVlanTag OBJECT-TYPE
-- SYNTAX INTEGER {
-- tag(1),
-- untag(2)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The port should transmit egress packets for this VLAN as tagged or untagged."
-- ::= { vdslPortVlanEntry 2 }
--
-- vdslPortVlanRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "This object is used to create a new row or delete an existing row in this table."
-- ::= { vdslPortVlanEntry 3 }
-- vdslVlanStaticTable
-- vdslVlanStaticTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF VdslVlanStaticEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "A table containing static configuration information for
-- each VLAN configured into the device by (local or
-- network) management. All entries are permanent and will
-- be restored after the device is reset.
-- This table is supported by R2.00 and later versions."
-- ::= { vdslVlan 3 }
--
-- vdslVlanStaticEntry OBJECT-TYPE
-- SYNTAX VdslVlanStaticEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry in vdslVlanStaticTable."
-- INDEX { dot1qVlanIndex }
-- ::= { vdslVlanStaticTable 1 }
--
-- VdslVlanStaticEntry ::=
-- SEQUENCE {
-- vdslVlanStaticEgressPorts PortList,
-- vdslVlanStaticUntaggedPorts PortList,
-- vdslVlanStaticRowStatus RowStatus
-- }
--
-- vdslVlanStaticEgressPorts OBJECT-TYPE
-- SYNTAX PortList
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The set of ports which are permanently assigned to the
-- egress list for this VLAN by management."
-- ::= { vdslVlanStaticEntry 1 }
--
-- vdslVlanStaticUntaggedPorts OBJECT-TYPE
-- SYNTAX PortList
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "The set of ports which should transmit egress packets for this VLAN as untagged."
-- ::= { vdslVlanStaticEntry 2 }
--
-- vdslVlanStaticRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "This object indicates the status of this entry."
-- ::= { vdslVlanStaticEntry 3 }
-- vdslPortPvlanTable
vdslPortPvlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslPortPvlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Protocol VLAN configuration table."
::= { vdslVlan 4 }
vdslPortPvlanEntry OBJECT-TYPE
SYNTAX VdslPortPvlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslPortPvlanTable."
INDEX { ifIndex, vdslPortPvlanEtype }
::= { vdslPortPvlanTable 1 }
VdslPortPvlanEntry ::=
SEQUENCE {
vdslPortPvlanEtype Unsigned32,
vdslPortPvlanVid VlanIndex,
vdslPortPvlanPriority INTEGER,
vdslPortPvlanRowStatus RowStatus
}
vdslPortPvlanEtype OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"0~0xffff."
::= { vdslPortPvlanEntry 1 }
vdslPortPvlanVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { vdslPortPvlanEntry 2 }
vdslPortPvlanPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { vdslPortPvlanEntry 3 }
vdslPortPvlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { vdslPortPvlanEntry 4 }
-- VDSL RFI Custom Table
vdslRfiCustomTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslRfiCustomEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes VDSL customized RFI configuration.
This table is supported by R2.00 and later versions."
::= { vdslPort 3 }
vdslRfiCustomEntry OBJECT-TYPE
SYNTAX VdslRfiCustomEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslRfiCustomTable."
INDEX { vdslRfiCustomIndex }
::= { vdslRfiCustomTable 1 }
VdslRfiCustomEntry ::=
SEQUENCE {
vdslRfiCustomIndex INTEGER,
vdslRfiCustomStartFreq INTEGER,
vdslRfiCustomEndFreq INTEGER,
vdslRfiCustomEnable INTEGER
}
vdslRfiCustomIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the table."
::= { vdslRfiCustomEntry 1 }
vdslRfiCustomStartFreq OBJECT-TYPE
SYNTAX INTEGER
UNITS "KHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The start value of the customized frequency range."
::= { vdslRfiCustomEntry 2 }
vdslRfiCustomEndFreq OBJECT-TYPE
SYNTAX INTEGER
UNITS "KHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The end value of the customized frequency range."
::= { vdslRfiCustomEntry 3 }
vdslRfiCustomEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable the customized frequency range setting."
::= { vdslRfiCustomEntry 4 }
-- vdslLineConfUpboParamTable
vdslLineConfUpboParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslLineConfUpboParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes VDSL UPBO configuration."
::= { vdslPort 4 }
vdslLineConfUpboParamEntry OBJECT-TYPE
SYNTAX VdslLineConfUpboParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslLineConfUpboParamTable."
INDEX { ifIndex,vdslLineConfUpboParamBand }
::= { vdslLineConfUpboParamTable 1 }
VdslLineConfUpboParamEntry ::=
SEQUENCE {
vdslLineConfUpboParamBand INTEGER,
vdslLineConfUpboParamA INTEGER,
vdslLineConfUpboParamB INTEGER
}
vdslLineConfUpboParamBand OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the table."
::= { vdslLineConfUpboParamEntry 1 }
vdslLineConfUpboParamA OBJECT-TYPE
SYNTAX INTEGER (4000..8095)
UNITS "0.01 dBm/Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { vdslLineConfUpboParamEntry 2 }
vdslLineConfUpboParamB OBJECT-TYPE
SYNTAX INTEGER (0..4095)
UNITS "0.01 dBm/Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { vdslLineConfUpboParamEntry 3 }
-- vdslLineConfDpboTable
vdslLineConfDpboTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslLineConfDpboEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes VDSL DPBO configuration."
::= { vdslPort 5 }
vdslLineConfDpboEntry OBJECT-TYPE
SYNTAX VdslLineConfDpboEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in vdslLineConfDpboTable."
INDEX { ifIndex, vdslLineConfDpboIndex }
::= { vdslLineConfDpboTable 1 }
VdslLineConfDpboEntry ::=
SEQUENCE {
vdslLineConfDpboIndex INTEGER,
vdslLineConfDpboTone INTEGER,
vdslLineConfDpboPsd INTEGER
}
vdslLineConfDpboIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the table."
::= { vdslLineConfDpboEntry 1 }
vdslLineConfDpboTone OBJECT-TYPE
SYNTAX INTEGER (1..512)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { vdslLineConfDpboEntry 2 }
vdslLineConfDpboPsd OBJECT-TYPE
SYNTAX INTEGER (0..255)
UNITS "-0.5dBm/Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { vdslLineConfDpboEntry 3 }
--------------------
-- pvc
--------------------
maxNumOfPvcs OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of PVCs which could be created on a port."
::= { pvc 1 }
-- PVC Table
pvcTable OBJECT-TYPE
SYNTAX SEQUENCE OF PvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes PVC configuration."
::= { pvc 2 }
pvcEntry OBJECT-TYPE
SYNTAX PvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in pvcTable."
INDEX { ifIndex, pvcVpi, pvcVci, pvcPvid }
::= { pvcTable 1 }
PvcEntry ::=
SEQUENCE {
-- Common --
pvcVpi INTEGER,
pvcVci INTEGER,
pvcPvid VlanIndex,
pvcPriority INTEGER,
pvcProfile DisplayString,
pvcAuto INTEGER,
-- Only for pvc --
pvcEncap INTEGER,
-- Only for paepvc --
pvcAcName DisplayString,
pvcServiceName DisplayString,
pvcHelloTime INTEGER,
-- Other --
pvcRowStatus RowStatus
}
-- Common --
pvcVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the pvc."
::= { pvcEntry 1 }
pvcVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the pvc."
::= { pvcEntry 2 }
pvcPvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default VID of the pvc."
::= { pvcEntry 3 }
pvcPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"802.1p default priority of the pvc."
::= { pvcEntry 5 }
pvcProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row in the ipqosProfileTable.
"
::= { pvcEntry 6 }
pvcAuto OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/disable auto detection for PPPoE/PPPoA encapsulation."
::= { pvcEntry 14 }
-- Only for PVC --
pvcEncap OBJECT-TYPE
SYNTAX INTEGER {
llc(1),
vc(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encapsulation of the pvc."
::= { pvcEntry 7 }
-- Other --
pvcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { pvcEntry 8 }
-- Only for PAEPVC --
pvcAcName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Access concentrator name for paepvc."
::= { pvcEntry 11 }
pvcServiceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Service name for paepvc."
::= { pvcEntry 12 }
pvcHelloTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The system will close the PVC if there are not any LCP echo messages passed through during the LCP hello time."
::= { pvcEntry 13 }
-- PVC state --
pvcStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF PvcStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table show current PVC status."
::= { pvc 3 }
pvcStateEntry OBJECT-TYPE
SYNTAX PvcStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in pvcStateTable."
INDEX { ifIndex, pvcStateVpi, pvcStateVci, pvcStatePvid }
::= { pvcStateTable 1 }
PvcStateEntry ::=
SEQUENCE {
pvcStateVpi INTEGER,
pvcStateVci INTEGER,
pvcStatePvid VlanIndex,
pvcStatePriority INTEGER,
--pvcStateCvid VlanIndex,
--pvcStateCPriority INTEGER,
--pvcStateMode DisplayString,
pvcStateChannelType DisplayString,
pvcStateEncap DisplayString
}
pvcStateVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the pvc."
::= { pvcStateEntry 1 }
pvcStateVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the pvc."
::= { pvcStateEntry 2 }
pvcStatePvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default VID of the pvc."
::= { pvcStateEntry 3 }
pvcStatePriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"802.1p default priority of the pvc."
::= { pvcStateEntry 4 }
--pvcStateCvid OBJECT-TYPE
--SYNTAX VlanIndex
--MAX-ACCESS read-only
--STATUS current
--DESCRIPTION
--"Default C-VID for paepvc."
--::= { pvcStateEntry 5 }
--pvcStateCPriority OBJECT-TYPE
--SYNTAX INTEGER (0..7)
--MAX-ACCESS read-only
--STATUS current
--DESCRIPTION
--"802.1p default C-priority for paepvc."
--::= { pvcStateEntry 6 }
--pvcStateMode OBJECT-TYPE
--SYNTAX DisplayString (SIZE (1..31))
--MAX-ACCESS read-only
--STATUS current
--DESCRIPTION
--"The value of this object identifies the link mode at runntime."
--::= { pvcStateEntry 7 }
pvcStateChannelType OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the channel type at runtime."
::= { pvcStateEntry 8 }
pvcStateEncap OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the channel encapsulation at runtime."
::= { pvcStateEntry 9 }
-------------------------------
-- 2684 routed mode pvc (rpvc)
-------------------------------
-- Routed Gateway Table
rpvcGatewayTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpvcGatewayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Routed Gateway configuration."
::= { rpvc 1 }
rpvcGatewayEntry OBJECT-TYPE
SYNTAX RpvcGatewayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in Routed Gateway table."
INDEX { rpvcGatewayIp }
::= { rpvcGatewayTable 1 }
RpvcGatewayEntry ::=
SEQUENCE {
rpvcGatewayIp IpAddress,
rpvcGatewayVlanId VlanIndex,
rpvcGatewayRowStatus RowStatus,
rpvcGatewayPriority INTEGER
}
rpvcGatewayIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP of RPVC gateway."
::= { rpvcGatewayEntry 1 }
rpvcGatewayVlanId OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Vlan id send to this RPVC gateway."
::= { rpvcGatewayEntry 2 }
rpvcGatewayRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { rpvcGatewayEntry 3 }
rpvcGatewayPriority OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"802.1p p bit send to this RPVC gateway."
::= { rpvcGatewayEntry 4 }
-- Routed PVC Table
rpvcTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes RPVC configuration."
::= { rpvc 2 }
rpvcEntry OBJECT-TYPE
SYNTAX RpvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in rpvcTable."
INDEX { ifIndex, rpvcVpi, rpvcVci, rpvcIp, rpvcNetmask }
::= { rpvcTable 1 }
RpvcEntry ::=
SEQUENCE {
rpvcVpi INTEGER,
rpvcVci INTEGER,
rpvcEncap INTEGER,
rpvcProfile DisplayString,
rpvcIp IpAddress,
rpvcNetmask IpAddress,
rpvcGatewayIpAddress IpAddress,
rpvcRowStatus RowStatus
}
rpvcVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the rpvc."
::= { rpvcEntry 1 }
rpvcVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the rpvc."
::= { rpvcEntry 2 }
rpvcEncap OBJECT-TYPE
SYNTAX INTEGER {
llc(1),
vc(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encapsulation of the rpvc."
::= { rpvcEntry 3 }
rpvcProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ipqos profile of the rpvc."
::= { rpvcEntry 4 }
rpvcIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP of the rpvc."
::= { rpvcEntry 5 }
rpvcNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP mask of the rpvc IP."
::= { rpvcEntry 6 }
rpvcGatewayIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The gateway IP of rpvc."
::= { rpvcEntry 7 }
rpvcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { rpvcEntry 8 }
-- Routed PVC Routed Domain Table
rpvcRouteDomainTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpvcRouteDomainEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes RPVC route domain configuration."
::= { rpvc 3 }
rpvcRouteDomainEntry OBJECT-TYPE
SYNTAX RpvcRouteDomainEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in rpvcRouteDomainTable."
INDEX { ifIndex, rpvcRouteDomainVpi, rpvcRouteDomainVci, rpvcRouteDomainIp, rpvcRouteDomainNetmask }
::= { rpvcRouteDomainTable 1 }
RpvcRouteDomainEntry ::=
SEQUENCE {
rpvcRouteDomainVpi INTEGER,
rpvcRouteDomainVci INTEGER,
rpvcRouteDomainIp IpAddress,
rpvcRouteDomainNetmask IpAddress,
rpvcRouteDomainRowStatus RowStatus
}
rpvcRouteDomainVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the rpvc."
::= { rpvcRouteDomainEntry 1 }
rpvcRouteDomainVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the rpvc."
::= { rpvcRouteDomainEntry 2 }
rpvcRouteDomainIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The route domain IP."
::= { rpvcRouteDomainEntry 3 }
rpvcRouteDomainNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP mask of the route domain IP."
::= { rpvcRouteDomainEntry 4 }
rpvcRouteDomainRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { rpvcRouteDomainEntry 5 }
rpvcArpAgingTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set RPVC ARP proxy aging time 10..10000 seconds,
0 to disable againg."
::= { rpvc 4 }
rpvcArpFlush OBJECT-TYPE
SYNTAX INTEGER {
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flush the RPVC ARP proxy table."
::= { rpvc 5 }
--------------------
-- dsBcastDisableTable
--------------------
dsBcastDisableTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsBcastDisableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Down Stream Bcast configuration."
::= { port 9 }
dsBcastDisableEntry OBJECT-TYPE
SYNTAX DsBcastDisableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in Down Stream Bcast table."
INDEX { ifIndex, dsBcastDisableVlanId }
::= { dsBcastDisableTable 1 }
DsBcastDisableEntry ::=
SEQUENCE {
dsBcastDisableVlanId INTEGER,
dsBcastDisableRowStatus RowStatus
}
dsBcastDisableVlanId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"downstream broadcast disabled vid."
::= { dsBcastDisableEntry 1 }
dsBcastDisableRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { dsBcastDisableEntry 2 }
--------------------
-- paepvc
--------------------
-- PPPoAoE PVC Table
paepvcTable OBJECT-TYPE
SYNTAX SEQUENCE OF PaepvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes PPPoAoE PVC configuration."
::= { paepvc 1 }
paepvcEntry OBJECT-TYPE
SYNTAX PaepvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of paepvcTable."
INDEX { ifIndex, paepvcVpi, paepvcVci, paepvcPvid }
::= { paepvcTable 1 }
PaepvcEntry ::=
SEQUENCE {
paepvcVpi INTEGER,
paepvcVci INTEGER,
paepvcPvid VlanIndex,
paepvcEncap INTEGER,
paepvcPriority INTEGER,
paepvcProfile DisplayString,
paepvcAcName DisplayString,
paepvcServiceName DisplayString,
paepvcHelloTime INTEGER,
paepvcRowStatus RowStatus,
paepvcCvid VlanIndex,
paepvcCPriority INTEGER
}
paepvcVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the pvc."
::= { paepvcEntry 1 }
paepvcVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the pvc."
::= { paepvcEntry 2 }
paepvcPvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default VID of the pvc."
::= { paepvcEntry 3 }
paepvcEncap OBJECT-TYPE
SYNTAX INTEGER {
llc(1),
vc(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encapsulation of the paepvc."
::= { paepvcEntry 4 }
paepvcPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"802.1p default priority of the pvc."
::= { paepvcEntry 5 }
paepvcProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row in the ipqosProfileTable."
::= { paepvcEntry 6 }
paepvcAcName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Access concentrator name."
::= { paepvcEntry 7 }
paepvcServiceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Service name."
::= { paepvcEntry 8 }
paepvcHelloTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The system will close the PVC if there are not any LCP echo messages passed through
during the LCP hello time."
::= { paepvcEntry 9 }
paepvcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { paepvcEntry 10 }
paepvcCvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Default C-VID of the pvc."
::= { paepvcEntry 12 }
paepvcCPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"802.1p default C-priority of the pvc."
::= { paepvcEntry 13 }
--------------------
-- tlspvc
--------------------
-- TLS PVC Table
tlspvcTable OBJECT-TYPE
SYNTAX SEQUENCE OF TlspvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Transparent LAN Service (TLS) PVC configuration."
::= { tlspvc 1 }
tlspvcEntry OBJECT-TYPE
SYNTAX TlspvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of tlspvcTable."
INDEX { ifIndex, tlspvcVpi, tlspvcVci, tlspvcSvid }
::= { tlspvcTable 1 }
TlspvcEntry ::=
SEQUENCE {
tlspvcVpi INTEGER,
tlspvcVci INTEGER,
tlspvcSvid VlanIndex,
tlspvcEncap INTEGER,
tlspvcSpriority INTEGER,
tlspvcProfile DisplayString,
tlspvcRowStatus RowStatus
}
tlspvcVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the pvc."
::= { tlspvcEntry 1 }
tlspvcVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the pvc."
::= { tlspvcEntry 2 }
tlspvcSvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"s-tag VLAN ID of the pvc."
::= { tlspvcEntry 3 }
tlspvcEncap OBJECT-TYPE
SYNTAX INTEGER {
llc(1),
vc(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encapsulation of the tlspvc."
::= { tlspvcEntry 4 }
tlspvcSpriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"s-tag priority of the pvc."
::= { tlspvcEntry 5 }
tlspvcProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row in the ipqosProfileTable."
::= { tlspvcEntry 6 }
tlspvcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { tlspvcEntry 7 }
--------------------
-- dtpvc
--------------------
-- DT PVC Table
dtpvcTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtpvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Double Tagging (DT) PVC configuration."
::= { dtpvc 1 }
dtpvcEntry OBJECT-TYPE
SYNTAX DtpvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dtpvcTable."
INDEX { ifIndex, dtpvcVpi, dtpvcVci, dtpvcSvid }
::= { dtpvcTable 1 }
DtpvcEntry ::=
SEQUENCE {
-- Common --
dtpvcVpi INTEGER,
dtpvcVci INTEGER,
dtpvcSvid VlanIndex,
dtpvcSpriority INTEGER,
dtpvcCvid VlanIndex,
dtpvcCpriority INTEGER,
dtpvcEncap INTEGER,
dtpvcProfile DisplayString,
dtpvcRowStatus RowStatus,
dtpvcAuto INTEGER,
-- Only for dtpvc --
dtpvcSuperChannel INTEGER,
-- Only for paepvc --
dtpvcAcName DisplayString,
dtpvcServiceName DisplayString,
dtpvcHelloTime INTEGER
}
-- Common --
dtpvcVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the pvc."
::= { dtpvcEntry 1 }
dtpvcVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the pvc."
::= { dtpvcEntry 2 }
dtpvcSvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"s-tag VLAN ID of the pvc."
::= { dtpvcEntry 3 }
dtpvcSpriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"s-tag priority of the pvc."
::= { dtpvcEntry 4 }
dtpvcCvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"c-tag VLAN ID of the pvc."
::= { dtpvcEntry 5 }
dtpvcCpriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"c-tag priority of the pvc."
::= { dtpvcEntry 6 }
dtpvcEncap OBJECT-TYPE
SYNTAX INTEGER {
llc(1),
vc(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encapsulation of the dtpvc."
::= { dtpvcEntry 7 }
dtpvcProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row in the ipqosProfileTable."
::= { dtpvcEntry 8 }
dtpvcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in this table."
::= { dtpvcEntry 9 }
dtpvcAuto OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/disable auto detection for PPPoE/PPPoA encapsulation."
::= { dtpvcEntry 14 }
-- Only for DTPVC --
dtpvcSuperChannel OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specified the configured DTPVC is a super channel."
::= { dtpvcEntry 10 }
-- Only for PAEPVC --
dtpvcAcName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Access concentrator name for paepvc."
::= { dtpvcEntry 11 }
dtpvcServiceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Service name for paepvc."
::= { dtpvcEntry 12 }
dtpvcHelloTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The system will close the PVC if there are not any LCP echo messages passed through during the LCP hello time."
::= { dtpvcEntry 13 }
-- DTPVC state --
dtpvcStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtpvcStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table show current DTPVC status."
::= { dtpvc 2 }
dtpvcStateEntry OBJECT-TYPE
SYNTAX DtpvcStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in dtpvcStateTable."
INDEX { ifIndex, dtpvcStateVpi, dtpvcStateVci, dtpvcStateSvid }
::= { dtpvcStateTable 1 }
DtpvcStateEntry ::=
SEQUENCE {
dtpvcStateVpi INTEGER,
dtpvcStateVci INTEGER,
dtpvcStateSvid VlanIndex,
dtpvcStateSPriority INTEGER,
dtpvcStateCvid VlanIndex,
dtpvcStateCPriority INTEGER,
--dtpvcStateMode DisplayString,
dtpvcStateChannelType DisplayString,
dtpvcStateEncap DisplayString
}
dtpvcStateVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI of the dtpvc."
::= { dtpvcStateEntry 1 }
dtpvcStateVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI of the dtpvc."
::= { dtpvcStateEntry 2 }
dtpvcStateSvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default S-VID of the dtpvc."
::= { dtpvcStateEntry 3 }
dtpvcStateSPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"S-priority of the dtpvc."
::= { dtpvcStateEntry 4 }
dtpvcStateCvid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default C-VID of the dtpvc."
::= { dtpvcStateEntry 5 }
dtpvcStateCPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"C-priority of the dtpvc."
::= { dtpvcStateEntry 6 }
--dtpvcStateMode OBJECT-TYPE
--SYNTAX DisplayString (SIZE (1..31))
--MAX-ACCESS read-only
--STATUS current
--DESCRIPTION
--"The value of this object identifies the link mode at runntime."
--::= { dtpvcStateEntry 7 }
dtpvcStateChannelType OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the channel type at runtime."
::= { dtpvcStateEntry 8 }
dtpvcStateEncap OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the channel encapsulation at runtime."
::= { dtpvcStateEntry 9 }
--------------------
-- voipPort
--------------------
-- voipSipLineConfTable
voipSipLineConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipSipLineConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes common attributes describing the VoIP line."
::= { voipPort 1 }
voipSipLineConfEntry OBJECT-TYPE
SYNTAX VoipSipLineConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in voipSipLineConfTable."
INDEX { ifIndex }
::= { voipSipLineConfTable 1 }
VoipSipLineConfEntry ::=
SEQUENCE {
voipSipLineConfSipProfile OCTET STRING,
voipSipLineConfSipCallSvcProfile OCTET STRING,
voipSipLineConfDspProfile OCTET STRING
}
voipSipLineConfSipProfile OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SIP profile name."
::= { voipSipLineConfEntry 1 }
voipSipLineConfSipCallSvcProfile OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SIP call service profile name."
::= { voipSipLineConfEntry 2 }
voipSipLineConfDspProfile OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DSP profile name."
::= { voipSipLineConfEntry 3 }
--------------------
-- voipPortOperation
--------------------
portOperations OBJECT IDENTIFIER ::= { voipPort 2 }
voipPortTarget OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The managed object is used for identify the target on which
the port configuration should be performed. The target is encoded as:
Byte 1: 0, Reserved(chaises)
Byte 2~3: 0,0 Reserved(slot)
Byte 4: 0, Reserved
Byte 5~11:Each octet specifies a set of eight ports, with the first
octet specifying ports 1 through 8, etc."
::= { portOperations 1 }
voipPortOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The managed object is for VoIP configuration. When the EMS
wants to issue the desired operation, the EMS shall send SNMP-SET message to set
the corresponding bit value to be 1. The various bit positions are:
BIT 1: enable port
BIT 2: disable port"
::= { portOperations 2 }
--------------------
-- voipPortTelTable
--------------------
voipPortTelTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipPortTelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes VoIP tel for the port."
::= { voipPort 3 }
voipPortTelEntry OBJECT-TYPE
SYNTAX VoipPortTelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in voipPortTelTable."
INDEX { ifIndex }
::= { voipPortTelTable 1 }
VoipPortTelEntry ::=
SEQUENCE {
voipPortTel DisplayString
}
voipPortTel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VoIP's telephone number of the specified port."
::= { voipPortTelEntry 1 }
--------------------
-- voipH248PortOperation
--------------------
-- voipH248LineConfTable
voipH248LineConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipH248LineConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes common attributes describing the VoIP line."
::= { voipPort 4 }
voipH248LineConfEntry OBJECT-TYPE
SYNTAX VoipH248LineConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in voipH248LineConfTable."
INDEX { ifIndex }
::= { voipH248LineConfTable 1 }
VoipH248LineConfEntry ::=
SEQUENCE {
voipH248LineConfMgName OCTET STRING,
voipH248LineConfDspProfile OCTET STRING,
voipH248LineConfVBDProfile OCTET STRING
}
voipH248LineConfMgName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MG name."
::= { voipH248LineConfEntry 1 }
voipH248LineConfDspProfile OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DSP profile name."
::= { voipH248LineConfEntry 2 }
voipH248LineConfVBDProfile OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DSP profile name for Voice Band Data (FAX or Modem) mode."
::= { voipH248LineConfEntry 3 }
--------------------
-- voipPortH248Termination
--------------------
-- voipPortH248TerminationTable
voipPortH248TerminationTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipPortH248TerminationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Termination name."
::= { voipPort 5 }
voipPortH248TerminationEntry OBJECT-TYPE
SYNTAX VoipPortH248TerminationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in voipPortH248TerminationTable."
INDEX { ifIndex }
::= { voipPortH248TerminationTable 1 }
VoipPortH248TerminationEntry ::=
SEQUENCE {
voipPortH248TermName OCTET STRING
}
voipPortH248TermName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Termination name of MG."
::= { voipPortH248TerminationEntry 1 }
--------------------
-- voipPortGain
--------------------
-- voipPortGainTable
voipPortGainTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipPortGainEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Port Gain."
::= { voipPort 6 }
voipPortGainEntry OBJECT-TYPE
SYNTAX VoipPortGainEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in voipPortGainTable."
INDEX { ifIndex }
::= { voipPortGainTable 1 }
VoipPortGainEntry ::=
SEQUENCE {
voipPortTXGain INTEGER,
voipPortRXGain INTEGER
}
voipPortTXGain OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TX Gain of the port, -200~200 in unit of 0.1dB."
::= { voipPortGainEntry 1 }
voipPortRXGain OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RX Gain of the port, -200~200 in unit of 0.1dB."
::= { voipPortGainEntry 2 }
--------------------
-- voipPortSeizureMode
--------------------
-- voipPortSeizureModeTable
voipPortSeizureModeTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipPortSeizureModeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes Port Seizure Mode."
::= { voipPort 7 }
voipPortSeizureModeEntry OBJECT-TYPE
SYNTAX VoipPortSeizureModeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in voipPortSeizureModeTable."
INDEX { ifIndex }
::= { voipPortSeizureModeTable 1 }
VoipPortSeizureModeEntry ::=
SEQUENCE {
voipPortSeizureMode INTEGER
}
voipPortSeizureMode OBJECT-TYPE
SYNTAX INTEGER {
loopstart(1),
groundstart(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Seizure Mode."
::= { voipPortSeizureModeEntry 1 }
--------------------
-- voipPortSipAuth
--------------------
-- voipPortSipAuthTable
voipPortSipAuthTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipPortSipAuthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes VoIP port SIP authentication related configuration."
::= { voipPort 8 }
voipPortSipAuthEntry OBJECT-TYPE
SYNTAX VoipPortSipAuthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in voipPortSipAuthTable."
INDEX { ifIndex }
::= { voipPortSipAuthTable 1 }
VoipPortSipAuthEntry ::=
SEQUENCE {
voipPortSipAuthMode INTEGER,
voipPortSipAuthUsername OCTET STRING,
voipPortSipAuthPasswdOn INTEGER,
voipPortSipAuthPasswd OCTET STRING
}
voipPortSipAuthMode OBJECT-TYPE
SYNTAX INTEGER {
profile(1),
line(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Authentication mode for VoIP port SIP registration."
::= { voipPortSipAuthEntry 1 }
voipPortSipAuthUsername OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VoIP port SIP registration username."
::= { voipPortSipAuthEntry 2 }
voipPortSipAuthPasswdOn OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Password is necessary or not for VoIP port SIP registration."
::= { voipPortSipAuthEntry 3 }
voipPortSipAuthPasswd OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VoIP port SIP registration password."
::= { voipPortSipAuthEntry 4 }
--------------------
-- voipPortSipCallsvc
--------------------
-- voipPortSipCallsvcTable
voipPortSipCallsvcTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipPortSipCallsvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes VoIp port SIP call service related configuration."
::= { voipPort 9 }
voipPortSipCallsvcEntry OBJECT-TYPE
SYNTAX VoipPortSipCallsvcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in voipPortSipCallsvcTable."
INDEX { ifIndex }
::= { voipPortSipCallsvcTable 1 }
VoipPortSipCallsvcEntry ::=
SEQUENCE {
voipPortSipCallsvcMode INTEGER,
voipPortSipCallsvcStateMask INTEGER,
voipPortSipCallsvcCPCOn INTEGER,
voipPortSipCallsvcCPCTimeout INTEGER
}
voipPortSipCallsvcMode OBJECT-TYPE
SYNTAX INTEGER {
profile(1),
line(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VoIP port SIP call service mode."
::= { voipPortSipCallsvcEntry 1 }
voipPortSipCallsvcStateMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bit 1 callforward : call forward(Not supported)
Bit 2 callhold : call hold
Bit 3 callwait : call waiting
Bit 4 callreturn : call return(Not supported)
Bit 5 calltransfer : call transfer
Bit 6 clip : caller line identification presentation (Caller ID)
Bit 7 clir : caller line identification restriction
Bit 8 dnd : do not disturb
Bit 9 conference : native 3-way conference"
::= { voipPortSipCallsvcEntry 2 }
voipPortSipCallsvcCPCOn OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Perform calling party control, or turn off."
::= { voipPortSipCallsvcEntry 3 }
voipPortSipCallsvcCPCTimeout OBJECT-TYPE
SYNTAX INTEGER (5..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VoIP port SIP delay hang up time of called party in seconds."
::= { voipPortSipCallsvcEntry 4 }
--------------------
-- snrMgn
--------------------
-- snrMgnTable
snrMgnTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnrMarginEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the per port SNR Margin configuration."
::= { snrMgn 1 }
snrMgnEntry OBJECT-TYPE
SYNTAX SnrMarginEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of snrMgnTable."
INDEX { ifIndex }
::= { snrMgnTable 1 }
SnrMarginEntry ::=
SEQUENCE {
snrMgnMode INTEGER,
snrMgnUcTarget INTEGER,
snrMgnUcMax INTEGER,
snrMgnUcMin INTEGER,
snrMgnUcDownshift INTEGER,
snrMgnUcUpshift INTEGER,
snrMgnUrTarget INTEGER,
snrMgnUrMax INTEGER,
snrMgnUrMin INTEGER,
snrMgnUrDownshift INTEGER,
snrMgnUrUpshift INTEGER
}
snrMgnMode OBJECT-TYPE
SYNTAX INTEGER {
profile(0),
line(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure DSL SNR margin configuration mode of the specified ports.
Profile: the SNR margin configuration comes from DSL profile.
Line: the SNR margin configuration comes from line configuration."
::= { snrMgnEntry 1 }
snrMgnUcTarget OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Target Signal/Noise Margin.
This is the Noise Margin the modem must achieve
with a BER of 10-7 or better to successfully complete
initialization."
::= { snrMgnEntry 2 }
snrMgnUcMax OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Maximum acceptable Signal/Noise Margin.
If the Noise Margin is above this the modem should
attempt to reduce its power output to optimize its
operation."
::= { snrMgnEntry 3 }
snrMgnUcMin OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Minimum acceptable Signal/Noise Margin.
If the noise margin falls below this level, the modem
should attempt to increase its power output. If that
is not possible the modem will attempt to
re-initialize or shut down."
::= { snrMgnEntry 4 }
snrMgnUcDownshift OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Signal/Noise Margin for rate downshift.
If the noise margin falls below this level, the modem
should attempt to decrease its transmit rate. In
the case that RADSL mode is not present,
the value will be `0'."
::= { snrMgnEntry 5 }
snrMgnUcUpshift OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Signal/Noise Margin for rate upshift.
If the noise margin rises above this level, the modem
should attempt to increase its transmit rate. In
the case that RADSL is not present, the value will
be `0'."
::= { snrMgnEntry 6 }
snrMgnUrTarget OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Target Signal/Noise Margin.
This is the Noise Margin the modem must achieve
with a BER of 10-7 or better to successfully complete
initialization."
::= { snrMgnEntry 7 }
snrMgnUrMax OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Maximum acceptable Signal/Noise Margin.
If the Noise Margin is above this the modem should
attempt to reduce its power output to optimize its
operation."
::= { snrMgnEntry 8 }
snrMgnUrMin OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Minimum acceptable Signal/Noise Margin.
If the noise margin falls below this level, the modem
should attempt to increase its power output. If that
is not possible the modem will attempt to
re-initialize or shut down."
::= { snrMgnEntry 9 }
snrMgnUrDownshift OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Signal/Noise Margin for rate downshift.
If the noise margin falls below this level, the modem
should attempt to decrease its transmit rate.
In the case that RADSL mode is not present,
the value will be `0'."
::= { snrMgnEntry 10 }
snrMgnUrUpshift OBJECT-TYPE
SYNTAX INTEGER (0..310)
UNITS "tenth dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Signal/Noise Margin for rate upshift.
If the noise margin rises above this level, the modem
should attempt to increase its transmit rate.
In the case that RADSL is not present,
the value will be `0'."
::= { snrMgnEntry 11 }
--------------------
-- dsl rate
--------------------
-- dslRateTable
dslRateTable OBJECT-TYPE
SYNTAX SEQUENCE OF DslRateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the per port DSL Rate configuration."
::= { dslRate 1 }
dslRateEntry OBJECT-TYPE
SYNTAX DslRateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dslRateTable."
INDEX { ifIndex }
::= { dslRateTable 1 }
DslRateEntry ::=
SEQUENCE {
dslRateMode INTEGER,
dslRateLatencyMode INTEGER,
dslRateXtucMaxInterleaveDelay INTEGER,
dslRateXtucMaxTxRate Unsigned32,
dslRateXtucMinTxRate Unsigned32,
dslRateXturMaxInterleaveDelay INTEGER,
dslRateXturMaxTxRate Unsigned32,
dslRateXturMinTxRate Unsigned32
}
dslRateMode OBJECT-TYPE
SYNTAX INTEGER {
profile(0),
line(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure DSL Rate configuration mode of the specified ports.
Profile: the DSL Rate configuration comes from DSL profile.
Line: the DSL Rate configuration comes from line configuration."
::= { dslRateEntry 1 }
dslRateLatencyMode OBJECT-TYPE
SYNTAX INTEGER {
interleave(1),
fast(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The latency mode is fast or interleave"
::= { dslRateEntry 2 }
dslRateXtucMaxInterleaveDelay OBJECT-TYPE
SYNTAX INTEGER (0..255)
UNITS "milli-seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured maximum Interleave Delay for this channel.
Interleave delay applies only to the interleave channel
and defines the mapping (relative spacing) between
subsequent input bytes at the interleaver input and
their placement in the bit stream at the interleaver
output. Larger numbers provide greater separation
between consecutive input bytes in the output bit
stream allowing for improved impulse noise immunity
at the expense of payload latency."
::= { dslRateEntry 3 }
dslRateXtucMaxTxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Maximum Transmit rate for `Fast' or `Interleave' channels,
in bps."
::= { dslRateEntry 4 }
dslRateXtucMinTxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Minimum Transmit rate for `Fast' or `Interleave' channels,
in bps"
::= { dslRateEntry 5 }
dslRateXturMaxInterleaveDelay OBJECT-TYPE
SYNTAX INTEGER (0..255)
UNITS "milli-seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured maximum Interleave Delay for this channel.
Interleave delay applies only to the interleave channel
and defines the mapping (relative spacing) between
subsequent input bytes at the interleaver input and
their placement in the bit stream at the interleaver
output. Larger numbers provide greater separation
between consecutive input bytes in the output bit
stream allowing for improved impulse noise immunity
at the expense of payload latency"
::= { dslRateEntry 6 }
dslRateXturMaxTxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Target Signal/Noise Margin.
This is the Noise Margin the modem must achieve
with a BER of 10-7 or better to successfully complete
initialization."
::= { dslRateEntry 7 }
dslRateXturMinTxRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured Maximum Transmit rate for `Fast' or `Interleave' channels,
in bps."
::= { dslRateEntry 8 }
--------------------
-- gbond
--------------------
-- gbondTable
gbondGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF GbondGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the G.Bond configuration information for
each bonding group of the device."
::= { gbond 1 }
gbondGroupEntry OBJECT-TYPE
SYNTAX GbondGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of gbondTable."
INDEX { gbondGroupName }
::= { gbondGroupTable 1 }
GbondGroupEntry ::=
SEQUENCE {
gbondGroupName OCTET STRING,
gbondGroupPorts OCTET STRING,
-- gbondGroupSid INTEGER,
gbondGroupUpRate Unsigned32,
gbondGroupDownRate Unsigned32,
gbondGroupRowStatus RowStatus
}
gbondGroupName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An administratively assigned string, which may be used to identify bonding group."
::= { gbondGroupEntry 1 }
gbondGroupPorts OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of ports which are currently assigned to the
bonding group of specified group name.
Byte 1: Reserved(chassis)
Byte 2~3: Reserved(slot)
Byte 4: Reserved
Byte 5~11:each octet specifies a set of eight ports, with the first
octet specifying ports 1 through 8, etc."
::= { gbondGroupEntry 2 }
-- gbondGroupSid OBJECT-TYPE
-- SYNTAX INTEGER {
-- sid8(1),
-- sid12(2)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "This object indicates the sequence index mode of the bonding group."
-- ::= { gbondGroupEntry 3 }
gbondGroupUpRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UP stream rate."
::= { gbondGroupEntry 4 }
gbondGroupDownRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DOWN stream rate."
::= { gbondGroupEntry 5 }
gbondGroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the status of this entry."
::= { gbondGroupEntry 6 }
----------------------------------------
-- profile
----------------------------------------
sraShiftMarginProfile OBJECT IDENTIFIER ::= { profile 1 }
voipProfile OBJECT IDENTIFIER ::= { profile 7 }
ipqosProfile OBJECT IDENTIFIER ::= { profile 8 }
--------------------
-- sraShiftMarginProfile
--------------------
-- sraShiftMarginProfile
sraShiftMarginProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF SraShiftMarginProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes sra shift margin related configuration."
::= { sraShiftMarginProfile 1 }
sraShiftMarginProfileEntry OBJECT-TYPE
SYNTAX SraShiftMarginProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in ipqosProfileTable."
INDEX { sraShiftMarginProfileName }
::= { sraShiftMarginProfileTable 1 }
SraShiftMarginProfileEntry ::=
SEQUENCE {
sraShiftMarginProfileName DisplayString,
xtucConfDownshiftSnrMgn INTEGER,
xtucConfUpshiftSnrMgn INTEGER,
xtucConfDownshiftTime INTEGER,
xtucConfUpshiftTime INTEGER,
xturConfDownshiftSnrMgn INTEGER,
xturConfUpshiftSnrMgn INTEGER,
xturConfDownshiftTime INTEGER,
xturConfUpshiftTime INTEGER,
sraShiftMarginProfileStatus RowStatus
}
sraShiftMarginProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies a row in this table."
::= { sraShiftMarginProfileEntry 1 }
xtucConfDownshiftSnrMgn OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the downstream SRA Down Shift Margin in units of 0.25 dB, for a range of 0 to 31.75 dB. in unit of 1 db."
::= { sraShiftMarginProfileEntry 2 }
xtucConfUpshiftSnrMgn OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the downstream SRA UP Shift Margin in units of 0.25 dB, for a range of 0 to 31.75 dB. in unit of 1 db."
::= { sraShiftMarginProfileEntry 3 }
xtucConfDownshiftTime OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the downstream SRA Down Shift time in units of 1 sec , for a range of 0 to 16383 sec. in unit of 1 sec."
::= { sraShiftMarginProfileEntry 4 }
xtucConfUpshiftTime OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the downstream SRA UP Shift time in units of 1 sec , for a range of 0 to 16383 sec. in unit of 1 sec."
::= { sraShiftMarginProfileEntry 5 }
xturConfDownshiftSnrMgn OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the upstream SRA Down Shift Margin in units of 0.25 dB, for a range of 0 to 31.75 dB. in unit of 1 db."
::= { sraShiftMarginProfileEntry 6 }
xturConfUpshiftSnrMgn OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the upstream SRA UP Shift Margin in units of 0.25 dB, for a range of 0 to 31.75 dB. in unit of 1 db."
::= { sraShiftMarginProfileEntry 7 }
xturConfDownshiftTime OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the upstream SRA Down Shift time in units of 1 sec , for a range of 0 to 16383 sec. in unit of 1 sec."
::= { sraShiftMarginProfileEntry 8 }
xturConfUpshiftTime OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the upstream SRA UP Shift time in units of 1 sec , for a range of 0 to 16383 sec. in unit of 1 sec."
::= { sraShiftMarginProfileEntry 9 }
sraShiftMarginProfileStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or modify or delete an existing row in this table."
::= { sraShiftMarginProfileEntry 10 }
--------------------
-- voipProfile
--------------------
sipProfile OBJECT IDENTIFIER ::= { voipProfile 1 }
-- sip profile
maxNumOfSipProfiles OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of SIP profiles supported by the system."
::= { sipProfile 1 }
sipProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF SipProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes SIP protocol related configuration."
::= { sipProfile 2 }
sipProfileEntry OBJECT-TYPE
SYNTAX SipProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in sipProfileTable."
INDEX { IMPLIED sipProfileName }
::= { sipProfileTable 1 }
SipProfileEntry ::=
SEQUENCE {
sipProfileName DisplayString,
sipProfileSipSvr OCTET STRING,
sipProfileRegSvr OCTET STRING,
sipProfileProxySvr OCTET STRING,
sipProfileSipPort INTEGER,
sipProfileRegSvrPort INTEGER,
sipProfileProxySvrPort INTEGER,
sipProfileUriType INTEGER,
sipProfilePbit INTEGER,
sipProfileDscp INTEGER,
sipProfileKeepAlive INTEGER,
sipProfileSe INTEGER,
sipProfilePrack INTEGER,
sipProfileRowStatus RowStatus,
sipProfileRegExpire INTEGER
}
sipProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used by the SIP profile table in order to identify a row of this table."
::= { sipProfileEntry 1 }
sipProfileSipSvr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP used for SIP registration or SIP domain name."
::= { sipProfileEntry 2 }
sipProfileRegSvr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Registration server IP or registration server domain name."
::= { sipProfileEntry 3 }
sipProfileProxySvr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Proxy server IP or proxy server doamin name."
::= { sipProfileEntry 4 }
sipProfileSipPort OBJECT-TYPE
SYNTAX INTEGER (1025..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"SIP UA port number."
::= { sipProfileEntry 5 }
sipProfileRegSvrPort OBJECT-TYPE
SYNTAX INTEGER (1025..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Registration server port number."
::= { sipProfileEntry 6 }
sipProfileProxySvrPort OBJECT-TYPE
SYNTAX INTEGER (1025..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Proxy server port number."
::= { sipProfileEntry 7 }
sipProfileUriType OBJECT-TYPE
SYNTAX INTEGER {
useSipUri(1),
useTelUri(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { sipProfileEntry 8 }
sipProfilePbit OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"802.1p bit for SIP and RTP packet."
::= { sipProfileEntry 9 }
sipProfileDscp OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"DSCP for SIP and RTP packet."
::= { sipProfileEntry 10 }
sipProfileKeepAlive OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { sipProfileEntry 11 }
sipProfileSe OBJECT-TYPE
SYNTAX INTEGER (90..65535)
UNITS "second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Session expiration time in seconds."
::= { sipProfileEntry 12 }
sipProfilePrack OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { sipProfileEntry 13 }
sipProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in the table."
::= { sipProfileEntry 14 }
sipProfileRegExpire OBJECT-TYPE
SYNTAX INTEGER (120..2073600)
UNITS "second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Registration expiration time in seconds."
::= { sipProfileEntry 15 }
-- sip call service profile
maxNumOfSipCallSvcProfiles OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of SIP call service profiles supported by the system."
::= { sipProfile 3 }
sipCallSvcProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF SipCallSvcProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes SIP call service related configuration."
::= { sipProfile 4 }
sipCallSvcProfileEntry OBJECT-TYPE
SYNTAX SipCallSvcProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in sipCallSvcProfileTable."
INDEX { IMPLIED sipCallSvcProfileName }
::= { sipCallSvcProfileTable 1 }
SipCallSvcProfileEntry ::=
SEQUENCE {
sipCallSvcProfileName DisplayString,
sipCallSvcProfilePasswdOn INTEGER,
sipCallSvcProfilePasswd OCTET STRING,
sipCallSvcProfileNumberPlanOn INTEGER,
sipCallSvcProfileNumberPlanCc OCTET STRING,
sipCallSvcProfileNumberPlanNdc OCTET STRING,
sipCallSvcProfileNumberPlanTable OCTET STRING,
sipCallSvcProfileStateMask INTEGER,
sipCallSvcProfileDtmf INTEGER,
sipCallSvcProfileFax INTEGER,
sipCallSvcProfileRowStatus RowStatus,
sipCallSvcProfileFlashType INTEGER,
sipCallSvcProfileFlashInfo OCTET STRING,
sipCallSvcProfileSoftSwitchType INTEGER,
sipCallSvcProfileCPCOn INTEGER,
sipCallSvcProfileCPCTimeout INTEGER
}
sipCallSvcProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used by the SIP call service profile table in order to identify a row of this table."
::= { sipCallSvcProfileEntry 1 }
sipCallSvcProfilePasswdOn OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Password is necessary or not for SIP registration."
::= { sipCallSvcProfileEntry 2 }
sipCallSvcProfilePasswd OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"SIP registration password."
::= { sipCallSvcProfileEntry 3 }
sipCallSvcProfileNumberPlanOn OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { sipCallSvcProfileEntry 4 }
sipCallSvcProfileNumberPlanCc OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Country code, only digit 0..9 are allowed."
::= { sipCallSvcProfileEntry 5 }
sipCallSvcProfileNumberPlanNdc OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"National destination code, only digit 0..9 are allowed."
::= { sipCallSvcProfileEntry 6 }
sipCallSvcProfileNumberPlanTable OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Numbering plan table name."
::= { sipCallSvcProfileEntry 7 }
sipCallSvcProfileStateMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Bit 1 callforward : call forward(Not supported)
Bit 2 callhold : call hold
Bit 3 callwait : call waiting
Bit 4 callreturn : call return(Not supported)
Bit 5 calltransfer : call transfer
Bit 6 clip : caller line identification presentation (Caller ID)
Bit 7 clir : caller line identification restriction
Bit 8 dnd : do not disturb
Bit 9 conference : native 3-way conference"
::= { sipCallSvcProfileEntry 8 }
sipCallSvcProfileDtmf OBJECT-TYPE
SYNTAX INTEGER {
bypass(1),
rfc2833(2),
rfc2833like(3),
sipinfo(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"dtmf bypass : bypass DTMF tone
dtmf rfc2833 : DTMF tone relay according to RFC2833
dtmf rfc2833like : DTMF tone relay by SIP INFO message, but RFC2833 payload
dtmf sipinfo : DTMF tone relay by SIP INFO message"
::= { sipCallSvcProfileEntry 9 }
sipCallSvcProfileFax OBJECT-TYPE
SYNTAX INTEGER {
g711(1),
t38(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"fax g711 : FAX service pass through by ITU-T G.711
fax t38 : FAX service by ITU-T T.38"
::= { sipCallSvcProfileEntry 10 }
sipCallSvcProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in the table."
::= { sipCallSvcProfileEntry 11 }
sipCallSvcProfileFlashType OBJECT-TYPE
SYNTAX INTEGER {
invite(1),
rfc2833(2),
rfc2833like(3),
sipinfo1(4),
sipinfo2(5),
sipinfo3(6),
sipinfo4(7),
sipinfo5(8),
sipinfo6(9),
bypass(10)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"flash invite : will send SIP INVITE message while press flash button.
flash bypass : flash event will be handled by current switch type specified in sipCallSvcProfileSwitchType.
flash rfc2833 : flash event will send by RTP event (16) defined in RFC 2833.
flash rfc2833like : flash event will send by SIP INFO message but RTP payload.
flash sipinfo-1 : flash event will be sent by SIP INFO signal=16 message.
flash sipinfo-2 : flash event will be sent by SIP INFO signal=hf message.
flash sipinfo-3 : flash event will be sent by SIP INFO signal=hook-flash message.
flash sipinfo-4 : flash event will be sent by SIP INFO plain text 'FLASH' message.
flash sipinfo-5 : flash event will be sent by multiple SIP INFO signal messages and content of signal messages come from sipCallSvcProfileFlashInfo.
flash sipinfo-6 : flash event will be sent by SIP INFO and payload is specified in sipCallSvcProfileFlashInfo."
::= { sipCallSvcProfileEntry 12 }
sipCallSvcProfileFlashInfo OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Strings carried in SIP INFO when specified in sipCallSvcProfileFlashType is sipinfo-5 and sipinfo-6."
::= { sipCallSvcProfileEntry 13 }
sipCallSvcProfileSoftSwitchType OBJECT-TYPE
SYNTAX INTEGER {
metaswitch(1),
nortel(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Softswitch type is configured to specify softswitch-dependent behavior,
currently only flash event is softswitch-dependent and should follow the softswitch type setting.
When configured the flash event to 'bypass', E5 will follow the softswitch type setting to
report hook flash event."
::= { sipCallSvcProfileEntry 14 }
sipCallSvcProfileCPCOn OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Perform calling party control, or turn off."
::= { sipCallSvcProfileEntry 15 }
sipCallSvcProfileCPCTimeout OBJECT-TYPE
SYNTAX INTEGER (5..60)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Delay hang up time of called party in seconds."
::= { sipCallSvcProfileEntry 16 }
-- dsp profile
maxNumOfDspProfiles OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of DSP profiles supported by the system."
::= { voipProfile 2 }
dspProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF DspProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes DSP related configuration."
::= { voipProfile 3 }
dspProfileEntry OBJECT-TYPE
SYNTAX DspProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in dspProfileTable."
INDEX { IMPLIED dspProfileName }
::= { dspProfileTable 1 }
DspProfileEntry ::=
SEQUENCE {
dspProfileName DisplayString,
dspProfileCodec OCTET STRING,
dspProfilePlayBufferMinDelay INTEGER,
dspProfilePlayBufferMaxDelay INTEGER,
dspProfileEchoTail INTEGER,
dspProfileRowStatus RowStatus,
dspProfileG711Vpi INTEGER,
dspProfileG723Vpi INTEGER,
dspProfileG726Vpi INTEGER,
dspProfileG729Vpi INTEGER
}
dspProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used by the DSP profile table in order to identify a row of this table."
::= { dspProfileEntry 1 }
dspProfileCodec OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"0x01: g711a
0x02: g711mu
0x03: g723
0x04: g726-16
0x05: g726-24
0x06: g726-32
0x07: g726-40
0x08: g729ab
the value of dspProfileCodec is OCTET STRING, there are 8 Octets, each octect is
specified as 0x01, 0x03, 0x02, 0x07,0x00, 0x00, 0x00, 0x00 (to specify different
CODE in priority) specify as: g711a, g723, g711mu, g726-40
"
::= { dspProfileEntry 2 }
dspProfilePlayBufferMinDelay OBJECT-TYPE
SYNTAX INTEGER (10..500)
UNITS "millisecond"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Play buffer minimum delay in milliseconds.
It should be less than or equal to dspProfilePlayBufferMaxDelay."
::= { dspProfileEntry 3 }
dspProfilePlayBufferMaxDelay OBJECT-TYPE
SYNTAX INTEGER (10..500)
UNITS "millisecond"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Play buffer maximum delay in milliseconds.
It should be greater than or equal to dspProfilePlayBufferMinDelay."
::= { dspProfileEntry 4 }
dspProfileEchoTail OBJECT-TYPE
SYNTAX INTEGER {
echotail8(1),
echotail16(2),
echotail32(3),
echotail128(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Echo cancellation echo tail period in milliseconds."
::= { dspProfileEntry 5 }
dspProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in the table."
::= { dspProfileEntry 6 }
dspProfileG711Vpi OBJECT-TYPE
SYNTAX INTEGER {
g711x10ms(1),
g711x20ms(2),
g711x30ms(3),
g711x40ms(4)
}
UNITS "millisecond"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Voice Packetization Interval(VPI) of codec G.711 in milliseconds.
The values are 10, 20, 30, 40"
::= { dspProfileEntry 7 }
dspProfileG723Vpi OBJECT-TYPE
SYNTAX INTEGER {
g723x30ms(1),
g723x60ms(2)
}
UNITS "millisecond"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Voice Packetization Interval(VPI) of G.723 codec in milliseconds.
The values are 30,60"
::= { dspProfileEntry 8 }
dspProfileG726Vpi OBJECT-TYPE
SYNTAX INTEGER {
g726x10ms(1),
g726x20ms(2),
g726x30ms(3),
g726x40ms(4)
}
UNITS "millisecond"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Voice Packetization Interval(VPI) of G.726 codec in milliseconds.
The values are 10, 20, 30, 40"
::= { dspProfileEntry 9 }
dspProfileG729Vpi OBJECT-TYPE
SYNTAX INTEGER {
g729x10ms(1),
g729x20ms(2),
g729x30ms(3),
g729x40ms(4),
g729x50ms(5),
g729x60ms(6)
}
UNITS "millisecond"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Voice Packetization Interval(VPI) of G.729 codec in milliseconds.
The values are 10, 20, 30, 40, 50, 60"
::= { dspProfileEntry 10 }
--h248 profile
h248Profile OBJECT IDENTIFIER ::= { voipProfile 4 }
maxNumOfH248Profiles OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of H248 profiles supported by the system."
::= { h248Profile 1 }
h248ProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF H248ProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes H248 profile related configuration."
::= { h248Profile 2 }
h248ProfileEntry OBJECT-TYPE
SYNTAX H248ProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in h248ProfileTable."
INDEX { IMPLIED h248ProfileName }
::= { h248ProfileTable 1 }
H248ProfileEntry ::=
SEQUENCE {
h248ProfileName DisplayString,
h248ProfileMgcSvr OCTET STRING,
h248ProfileMgcPort INTEGER,
h248ProfileMgc2On INTEGER,
h248ProfileMgc2Svr OCTET STRING,
h248ProfileMgc2Port INTEGER,
h248ProfileTransport INTEGER,
h248ProfileEncode INTEGER,
h248ProfilePbit INTEGER,
h248ProfileDscp INTEGER,
h248ProfileRowStatus RowStatus,
h248ProfileVbd INTEGER,
-- h248ProfileIt INTEGER,
h248ProfileEphemeralPrefix OCTET STRING,
h248ProfileSoftswitch INTEGER,
h248ProfileForceVer INTEGER,
h248ProfileStartRTPPort INTEGER,
h248ProfileEndRTPPort INTEGER,
h248ProfileEphemeralStartNumber OCTET STRING,
h248ProfileEphemeralSuffixLength INTEGER,
h248ProfilePhysicalPrefix OCTET STRING,
h248ProfilePhysicalStartNumber OCTET STRING,
h248ProfilePhysicalSuffixLength INTEGER,
h248ProfileRfc2833Mode INTEGER,
h248ProfileRfc2833ModePayloadType INTEGER
}
h248ProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used by the H248 profile table in order to identify a row of this table."
::= { h248ProfileEntry 1 }
h248ProfileMgcSvr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"MGC IP or MGC doamin name."
::= { h248ProfileEntry 2 }
h248ProfileMgcPort OBJECT-TYPE
SYNTAX INTEGER (1025..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"MGC port number."
::= { h248ProfileEntry 3 }
h248ProfileMgc2On OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Secondary MGC on/off."
::= { h248ProfileEntry 4 }
h248ProfileMgc2Svr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Secondary MGC IP or MGC doamin name. h248ProfileMgc2On needs to turn on if user want to set Secondary MGC IP or domain name."
::= { h248ProfileEntry 5 }
h248ProfileMgc2Port OBJECT-TYPE
SYNTAX INTEGER (1025..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Secondary MGC port number. h248ProfileMgc2On needs to turn on if user want to set Secondary MGC port number."
::= { h248ProfileEntry 6 }
h248ProfileTransport OBJECT-TYPE
SYNTAX INTEGER {
udp(1),
tcp(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Transport procotol used by the H.248 protocol stack."
::= { h248ProfileEntry 7 }
h248ProfileEncode OBJECT-TYPE
SYNTAX INTEGER {
longtext(1),
shorttext(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encoding type used by the H.248 protocol stack"
::= { h248ProfileEntry 8 }
h248ProfilePbit OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"802.1p bit for H.248 packet."
::= { h248ProfileEntry 9 }
h248ProfileDscp OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"DSCP for H.248 packet."
::= { h248ProfileEntry 10 }
h248ProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in the table."
::= { h248ProfileEntry 11 }
h248ProfileVbd OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VBD mode support on/off"
::= { h248ProfileEntry 12 }
-- remove since 3.0.2, ives 2009/12/24
-- h248ProfileIt OBJECT-TYPE
-- SYNTAX INTEGER (0..65535)
-- UNITS "10ms"
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Inactivity timer"
-- ::= { h248ProfileEntry 13 }
h248ProfileEphemeralPrefix OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Ephemeral Termination Prefix"
::= { h248ProfileEntry 14 }
h248ProfileSoftswitch OBJECT-TYPE
SYNTAX INTEGER {
metaswitch(1),
nortelCs1500(2),
nortelCs2000(3)
-- zxss10-ss(2) not support in calix
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Softswitch type"
::= { h248ProfileEntry 15 }
h248ProfileForceVer OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Force using H.248 version 1"
::= { h248ProfileEntry 16 }
h248ProfileStartRTPPort OBJECT-TYPE
SYNTAX INTEGER (4000..64000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Start of RTP port number."
::= { h248ProfileEntry 17 }
h248ProfileEndRTPPort OBJECT-TYPE
SYNTAX INTEGER (5000..65000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"End of RTP port number."
::= { h248ProfileEntry 18 }
h248ProfileEphemeralStartNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Ephemeral termination suffix start number, up to 15 digits."
::= { h248ProfileEntry 19 }
h248ProfileEphemeralSuffixLength OBJECT-TYPE
SYNTAX INTEGER (0..15)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Ephemeral termination suffix number length , padding zero at the front if not long enough."
::= { h248ProfileEntry 20 }
h248ProfilePhysicalPrefix OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Physical Termination Prefix."
::= { h248ProfileEntry 21 }
h248ProfilePhysicalStartNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Physical termination suffix start number, up to 15 digits."
::= { h248ProfileEntry 22 }
h248ProfilePhysicalSuffixLength OBJECT-TYPE
SYNTAX INTEGER (0..15)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Physical termination suffix number length , padding zero at the front if not long enough."
::= { h248ProfileEntry 23 }
h248ProfileRfc2833Mode OBJECT-TYPE
SYNTAX INTEGER {
On(1),
Off(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RFC2833 mode support."
::= { h248ProfileEntry 24 }
h248ProfileRfc2833ModePayloadType OBJECT-TYPE
SYNTAX INTEGER (96..127)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Payload type of RFC2833 mode."
::= { h248ProfileEntry 25 }
--------------------
-- ipqosProfile
--------------------
-- ipqosProfileTable
maxNumOfIpqosProfiles OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of IPQOS profiles supported by the system."
::= { ipqosProfile 1 }
ipqosProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpqosProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes IPQOS related configuration."
::= { ipqosProfile 2 }
ipqosProfileEntry OBJECT-TYPE
SYNTAX IpqosProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in ipqosProfileTable."
INDEX { ipqosProfileName , ipqosProfileNumOfQueue }
::= { ipqosProfileTable 1 }
IpqosProfileEntry ::=
SEQUENCE {
ipqosProfileName DisplayString,
ipqosProfileNumOfQueue INTEGER,
ipqosProfileRowStatus RowStatus
}
ipqosProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used by the IPQOS profile table in order to identify a row of this table."
::= { ipqosProfileEntry 1 }
ipqosProfileNumOfQueue OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of IPQOS queues."
::= { ipqosProfileEntry 2 }
ipqosProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or delete an existing row in the table."
::= { ipqosProfileEntry 3 }
-- ipqosProfileQueueTable
ipqosProfileQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpqosProfileQueueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes IPQOS queue related configuration."
::= { ipqosProfile 3 }
ipqosProfileQueueEntry OBJECT-TYPE
SYNTAX IpqosProfileQueueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in ipqosProfileQueueTable."
INDEX { ipqosProfileName , ipqosProfileQueueIndex }
::= { ipqosProfileQueueTable 1 }
IpqosProfileQueueEntry ::=
SEQUENCE {
ipqosProfileQueueIndex INTEGER,
ipqosProfileQueuePIR INTEGER,
ipqosProfileQueueCIR INTEGER,
ipqosProfileQueuePBS INTEGER,
ipqosProfileQueueCBS INTEGER,
ipqosProfileQueueLevel INTEGER,
ipqosProfileQueueWeight INTEGER
}
ipqosProfileQueueIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IPQOS queue index."
::= { ipqosProfileQueueEntry 1 }
ipqosProfileQueuePIR OBJECT-TYPE
SYNTAX INTEGER (512..131072)
UNITS "Kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Peak rate.(multiple of 256)"
::= { ipqosProfileQueueEntry 2 }
ipqosProfileQueueCIR OBJECT-TYPE
SYNTAX INTEGER (256..65536)
UNITS "Kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Commited rate.(multiple of 256)"
::= { ipqosProfileQueueEntry 3 }
ipqosProfileQueuePBS OBJECT-TYPE
SYNTAX INTEGER (3072..65536)
UNITS "byte"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Peak burst size.(mutiple of 256)"
::= { ipqosProfileQueueEntry 4 }
ipqosProfileQueueCBS OBJECT-TYPE
SYNTAX INTEGER (3072..65536)
UNITS "byts"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Commited burst size.(mutiple of 256)"
::= { ipqosProfileQueueEntry 5 }
ipqosProfileQueueLevel OBJECT-TYPE
SYNTAX INTEGER (0..7)
UNITS "byts"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Queue level."
::= { ipqosProfileQueueEntry 6 }
ipqosProfileQueueWeight OBJECT-TYPE
SYNTAX INTEGER (1..127)
UNITS "byts"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Queue weight."
::= { ipqosProfileQueueEntry 7 }
----------------------------------------
-- switch
----------------------------------------
dot3ad OBJECT IDENTIFIER ::= { switch 6 }
dscp OBJECT IDENTIFIER ::= { switch 10 }
vlanIsolation OBJECT IDENTIFIER ::= { switch 12 }
enetMtu OBJECT IDENTIFIER ::= { switch 13 }
tpid OBJECT IDENTIFIER ::= { switch 14 }
cfm OBJECT IDENTIFIER ::= { switch 15 }
-- Standalone IP DSLAM puts all ACL features in 'switch', from OID 51
dhcp OBJECT IDENTIFIER ::= { switch 51 }
macfilter OBJECT IDENTIFIER ::= { switch 53 }
dhcpSnoop OBJECT IDENTIFIER ::= { switch 55 }
acl OBJECT IDENTIFIER ::= { switch 56 }
pppoeAgent OBJECT IDENTIFIER ::= { switch 57 }
n1mac OBJECT IDENTIFIER ::= { switch 58 }
macff OBJECT IDENTIFIER ::= { switch 60 }
--------------------
-- dot3ad
--------------------
dot3adTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot3adEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains 802.3ad configuration."
::= { dot3ad 1 }
dot3adEntry OBJECT-TYPE
SYNTAX Dot3adEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { dot3adGroupId }
::= { dot3adTable 1 }
Dot3adEntry ::=
SEQUENCE {
dot3adGroupId INTEGER,
dot3adEnable INTEGER
}
dot3adGroupId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Group ID 1 for the subtending group and 2 for the uplink group."
::= { dot3adEntry 1 }
dot3adEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
enableWithLacp(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable 802.3ad function."
::= { dot3adEntry 2 }
lacpPriority OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LACP system priority."
::= { dot3ad 2 }
lacpTimeout OBJECT-TYPE
SYNTAX INTEGER {
shorttimeout(1),
longtimeout(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time interval to exchange LACP packets in order to check that the peer port
in the trunk group is still up."
::= { dot3ad 3 }
portTrunkingTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortTrunkingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains current status of port trunking."
::= { dot3ad 4 }
portTrunkingEntry OBJECT-TYPE
SYNTAX PortTrunkingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { portTrunkingGroupId }
::= { portTrunkingTable 1 }
PortTrunkingEntry ::=
SEQUENCE {
portTrunkingGroupId INTEGER,
portTrunkingStatus INTEGER,
portTrunkingPortList PortList
}
portTrunkingGroupId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Group ID 1 for the subtending group and 2 for the uplink group."
::= { portTrunkingEntry 1 }
portTrunkingStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port trunking status."
::= { portTrunkingEntry 2 }
portTrunkingPortList OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port list which actually joins the trunking group."
::= { portTrunkingEntry 3 }
--------------------
-- dscp
--------------------
dscpMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF DscpMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains DSCP mapping configuration for the adsl ports."
::= { dscp 1 }
dscpMappingEntry OBJECT-TYPE
SYNTAX DscpMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dscpMappingTable."
INDEX { dscpSrcCodePoint }
::= { dscpMappingTable 1 }
DscpMappingEntry ::=
SEQUENCE {
dscpSrcCodePoint INTEGER,
-- dscpMapCodePoint INTEGER,
dscpMapPriority INTEGER
}
dscpSrcCodePoint OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DSCP source code point used for mapping."
::= { dscpMappingEntry 1 }
-- dscpMapCodePoint OBJECT-TYPE
-- SYNTAX INTEGER (0..63)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The mapping code point that will replace the source code point in the incoming packet."
-- ::= { dscpMappingEntry 2 }
dscpMapPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mapping p bits that will replace the source p bits in the incoming packet."
::= { dscpMappingEntry 3 }
--- pfchen
dscpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DscpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains DSCP mapping configuration for the adsl ports."
::= { dscp 2 }
dscpPortEntry OBJECT-TYPE
SYNTAX DscpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dscpPortTable."
INDEX { ifIndex }
::= { dscpPortTable 1 }
DscpPortEntry ::=
SEQUENCE {
dscpStatusEnable INTEGER
}
dscpStatusEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DSCP port status."
::= { dscpPortEntry 1 }
--------------------
-- Vlan Isolation
--------------------
vlanIsolationTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanIsolationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table contains configuration of isolated VLAN."
::= { vlanIsolation 1 }
vlanIsolationEntry OBJECT-TYPE
SYNTAX VlanIsolationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of vlanIsolationTable."
INDEX { dot1qVlanIndex }
::= { vlanIsolationTable 1 }
VlanIsolationEntry ::=
SEQUENCE {
vlanIsolationRowStatus INTEGER
}
vlanIsolationRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status of the table used to create/delete an entry."
::= { vlanIsolationEntry 1 }
--------------------
-- enet MTU
--------------------
enetMtuEntry OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the MTU size for layer 2 frame, size from 1526 to 1532, default value is 1526."
::= { enetMtu 1 }
--------------------
-- TPID (Tag Protocol Identifier)
--------------------
tpidEntry OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets TPID(Tag Protocol Identifier) of tagged frame, 0~FFFF."
::= { tpid 1 }
--------------------
-- CFM
--------------------
-- cfmLoopbackPortTable
cfmLoopbackPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfmLoopbackPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains CFM information."
::= { cfm 1 }
cfmLoopbackPortEntry OBJECT-TYPE
SYNTAX CfmLoopbackPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in cfmLoopbackPortTable."
INDEX { ifIndex }
::= { cfmLoopbackPortTable 1 }
CfmLoopbackPortEntry ::= SEQUENCE {
cfmLoopbackPortState INTEGER
}
cfmLoopbackPortState OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CFM loopback enable/disable on the port."
::= { cfmLoopbackPortEntry 1 }
-- cfmMIPTable
cfmMIPTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfmMIPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { cfm 2 }
cfmMIPEntry OBJECT-TYPE
SYNTAX CfmMIPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in cfmMIPTable."
INDEX { dot1agCfmMdIndex, cfmPort }
::= { cfmMIPTable 1 }
CfmMIPEntry ::=
SEQUENCE {
cfmPort INTEGER,
cfmMIPRowStatus RowStatus,
cfmMIPMacAddr PhysAddress
}
-- cfmLevel OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { cfmMIPEntry 1 }
--
-- cfmVlanID OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { cfmMIPEntry 2 }
cfmPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { cfmMIPEntry 3 }
cfmMIPRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { cfmMIPEntry 4 }
cfmMIPMacAddr OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CFM MIP mac address"
::= { cfmMIPEntry 5 }
cfmActionEnableStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CFM Action enable status for the CO device"
::= { cfm 3 }
cfmMode OBJECT-TYPE
SYNTAX INTEGER {
mode802Dot1Ag(1),
modeYDot1731(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CFM follow standard mode"
::= { cfm 4 }
cfmLbmTimeout OBJECT-TYPE
SYNTAX INTEGER (100..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CFM LBM timeout, 100-86400 ms"
::= { cfm 5 }
cfmLbmDataTlvLength OBJECT-TYPE
SYNTAX INTEGER (0..1400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CFM LBM data tlv length, 0-1400 bytes"
::= { cfm 6 }
-- cfmLbrTable
cfmLbrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfmLbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains CFM LBR results."
::= { cfm 7 }
cfmLbrEntry OBJECT-TYPE
SYNTAX CfmLbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in cfmLbrTable."
INDEX { dot1agCfmMdIndex, dot1agCfmMaIndex, dot1agCfmMepIdentifier, cfmLbmIndex, cfmLbrIndex}
::= { cfmLbrTable 1 }
CfmLbrEntry ::= SEQUENCE {
cfmLbmIndex INTEGER,
cfmLbrIndex INTEGER,
cfmLbrSrcMac PhysAddress,
cfmLbrStatus INTEGER,
cfmLbrRtt INTEGER
}
cfmLbmIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CFM lbm index."
::= { cfmLbrEntry 1 }
cfmLbrIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CFM lbr index."
::= { cfmLbrEntry 2 }
cfmLbrSrcMac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CFM lbr source address."
::= { cfmLbrEntry 3 }
cfmLbrStatus OBJECT-TYPE
SYNTAX INTEGER {
ready(1),
notready(2),
xmit(3),
success(4),
timeout(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CFM lbr status."
::= { cfmLbrEntry 4 }
cfmLbrRtt OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CFM lbr rtt in ms."
::= { cfmLbrEntry 5 }
--------------------
-- DHCP Relay
--------------------
dhcpRelay82Table OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpRelay82Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains DHCP Relay configuration."
::= { dhcp 2 }
dhcpRelay82Entry OBJECT-TYPE
SYNTAX DhcpRelay82Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of DHCP Relay table."
INDEX { dot1qVlanIndex }
::= { dhcpRelay82Table 1 }
DhcpRelay82Entry ::=
SEQUENCE {
dhcpRelay82PrimaryServer IpAddress,
dhcpRelay82SecondaryServer IpAddress,
dhcpRelay82ActiveServer INTEGER,
dhcpRelay82Enable INTEGER,
dhcpRelay82Info DisplayString,
dhcpRelay82RelayMode INTEGER,
dhcpRelay82Suboption2Enable INTEGER,
dhcpRelay82Suboption2Info DisplayString,
dhcpRelay82EntryEnable INTEGER,
dhcpRelay82EntryOptionMode INTEGER,
dhcpRelay82VlanIp IpAddress,
dhcpRelay82VlanMask INTEGER,
dhcpRelay82VlanGateway IpAddress,
dhcpRelay82ThirdServer IpAddress,
dhcpRelay82FourthServer IpAddress,
dhcpRelay82FifthServer IpAddress,
dhcpRelay82ServerVid INTEGER
}
dhcpRelay82PrimaryServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the DHCP Relay primary server."
::= { dhcpRelay82Entry 1 }
dhcpRelay82SecondaryServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the DHCP Relay secondary server."
::= { dhcpRelay82Entry 2 }
dhcpRelay82ActiveServer OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2),
third(3),
fourth(4),
fifth(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current active DHCP Relay server."
::= { dhcpRelay82Entry 3 }
dhcpRelay82Enable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/disable DHCP relay and Option82 function."
::= { dhcpRelay82Entry 4 }
dhcpRelay82Info OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..23))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User specific Option82 information."
::= { dhcpRelay82Entry 5 }
dhcpRelay82RelayMode OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
all(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"DHCP relay mode."
::= { dhcpRelay82Entry 6 }
dhcpRelay82Suboption2Enable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/disable Option 82 sub-option 2."
::= { dhcpRelay82Entry 8 }
dhcpRelay82Suboption2Info OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User specified information for Option 82 sub-option 2."
::= { dhcpRelay82Entry 9 }
dhcpRelay82EntryEnable OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
all(2),
disable(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/disable DHCP Relay"
::= { dhcpRelay82Entry 10 }
dhcpRelay82EntryOptionMode OBJECT-TYPE
SYNTAX INTEGER {
private(1),
tr101(2),
customer-remote-id(3),
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Option82 format."
::= { dhcpRelay82Entry 11 }
dhcpRelay82VlanIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the DHCP Relay interface for this VLAN."
::= { dhcpRelay82Entry 12 }
dhcpRelay82VlanMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The network mask of the DHCP Relay interface for this VLAN."
::= { dhcpRelay82Entry 13 }
dhcpRelay82VlanGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gateway of the DHCP Relay interface for this VLAN."
::= { dhcpRelay82Entry 14 }
dhcpRelay82ThirdServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the DHCP Relay third server."
::= { dhcpRelay82Entry 15 }
dhcpRelay82FourthServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the DHCP Relay fourth server."
::= { dhcpRelay82Entry 16 }
dhcpRelay82FifthServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the DHCP Relay fifth server."
::= { dhcpRelay82Entry 17 }
dhcpRelay82ServerVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VID of the DHCP Relay server for this VLAN."
::= { dhcpRelay82Entry 18 }
-- dhcpRelayTest
dhcpRelayTest OBJECT IDENTIFIER ::= { dhcp 8 }
dhcpRelayTestVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the VID of the test server."
::= { dhcpRelayTest 1 }
dhcpRelayTestIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the IP of the test server."
::= { dhcpRelayTest 2 }
dhcpRelayTestOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the object to 1 to test DHCP server."
::= { dhcpRelayTest 3 }
dhcpRelayTestStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display testing server status."
::= { dhcpRelayTest 4 }
-- dhcpRelayArp
dhcpRelayArp OBJECT IDENTIFIER ::= { dhcp 9 }
dhcpRelayArpShowTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpRelayArpShowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table displays DHCP ARP."
::= { dhcpRelayArp 1 }
dhcpRelayArpShowEntry OBJECT-TYPE
SYNTAX DhcpRelayArpShowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dhcpRelayArpShowTable."
INDEX { dhcpRelayArpShowVid, dhcpRelayArpShowIp }
::= { dhcpRelayArpShowTable 1 }
DhcpRelayArpShowEntry ::=
SEQUENCE {
dhcpRelayArpShowVid INTEGER,
dhcpRelayArpShowIp IpAddress,
dhcpRelayArpShowMac PhysAddress
}
dhcpRelayArpShowVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display the VID of the DHCP ARP entry."
::= { dhcpRelayArpShowEntry 1 }
dhcpRelayArpShowIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display the IP of the DHCP ARP entry."
::= { dhcpRelayArpShowEntry 2 }
dhcpRelayArpShowMac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display the MAC of the DHCP ARP entry."
::= { dhcpRelayArpShowEntry 3 }
dhcpRelayArpFlushOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the object to 1 to start flushing."
::= { dhcpRelayArp 2 }
--------------------
-- MAC Filter
--------------------
-- MAC Filter Port Table
macFilterPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFilterPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes the status of mac filtering for each port."
::= { macfilter 1 }
macFilterPortEntry OBJECT-TYPE
SYNTAX MacFilterPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in macFilterPortTable."
INDEX { ifIndex }
::= { macFilterPortTable 1 }
MacFilterPortEntry ::=
SEQUENCE {
macFilterPortEnable INTEGER,
macFilterPortMacCount INTEGER,
macFilterPortFilterMode INTEGER
}
macFilterPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enableMacFilter(1),
enableMacCount(2),
-- enableOuiFilter(3),
disable(4),
enableMacFilterAndMacCount(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable MAC filtering for the port."
::= { macFilterPortEntry 1 }
macFilterPortMacCount OBJECT-TYPE
SYNTAX INTEGER (1..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The total number of MAC addresses allowed for the port."
::= { macFilterPortEntry 2 }
macFilterPortFilterMode OBJECT-TYPE
SYNTAX INTEGER {
accept(1),
deny(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mac filter mode (accept or deny) for the port."
::= { macFilterPortEntry 3 }
maxNumOfMacFiltersInSystem OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of mac filters supported in the system."
::= { macfilter 2 }
maxNumOfMacFiltersPerPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of mac filters supported per port."
::= { macfilter 3 }
currNumOfMacFiltersInSystem OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of mac filters in the system."
::= { macfilter 4 }
-- MAC Table
macFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains the mac filter addresses."
::= { macfilter 5 }
macFilterEntry OBJECT-TYPE
SYNTAX MacFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of macFilterTable."
INDEX { ifIndex, macFilterAddr }
::= { macFilterTable 1 }
MacFilterEntry ::=
SEQUENCE {
macFilterAddr PhysAddress,
macFilterRowStatus RowStatus
}
macFilterAddr OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mac address which can pass through or be rejected from the port."
::= { macFilterEntry 1 }
macFilterRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of the entry."
::= { macFilterEntry 2 }
-- Batch Set for MAC Filter
macfilterBatchSet OBJECT IDENTIFIER ::= { macfilter 6 }
macfilterTarget OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This managed object is used for identify the target on which
the port configuration should be performed. The target is encoded as:
Byte 1: 0, Reserved(chassis)
Byte 2~3: 0, Reserved(slot)
Byte 4: 0, reserved
Byte 5~11:each octet specifies a set of eight ports, with the first
octet specifying ports 1 through 8, etc."
::= { macfilterBatchSet 1 }
macfilterOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The corresponding bit is set to 1 to start the operation.
The various bit positions are:
BIT 1: enable mac filter
BIT 2: enable mac count filter
BIT 3: disable mac filter
BIT 4: set mac count
BIT 5: disable mac count filter."
::= { macfilterBatchSet 2 }
macFilterMacCountForBatchSet OBJECT-TYPE
SYNTAX INTEGER (1..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The total number of MAC addresses allowed for a port."
::= { macfilterBatchSet 3 }
-- OUI Filter Table
ouiFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF OuiFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains the OUI filter addresses."
::= { macfilter 7 }
ouiFilterEntry OBJECT-TYPE
SYNTAX OuiFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of ouiFilterTable."
INDEX { ifIndex, ouiFilterAddr }
::= { ouiFilterTable 1 }
OuiFilterEntry ::=
SEQUENCE {
ouiFilterAddr OCTET STRING,
ouiFilterRowStatus RowStatus
}
ouiFilterAddr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first three bytes of the mac address which can pass through or be rejected from the port."
::= { ouiFilterEntry 1 }
ouiFilterRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of the entry."
::= { ouiFilterEntry 2 }
maxNumOfOuiFiltersPerPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of OUI filters supported per port."
::= { macfilter 8 }
ouiFilterPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF OuiFilterPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes the status of oui filtering for each port."
::= { macfilter 9 }
ouiFilterPortEntry OBJECT-TYPE
SYNTAX OuiFilterPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in macFilterPortTable."
INDEX { ifIndex }
::= { ouiFilterPortTable 1 }
OuiFilterPortEntry ::=
SEQUENCE {
ouiFilterPortEnable INTEGER,
ouiFilterPortFilterMode INTEGER
}
ouiFilterPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enableOuiFilter(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable oui filtering for the port."
::= { ouiFilterPortEntry 1 }
ouiFilterPortFilterMode OBJECT-TYPE
SYNTAX INTEGER {
accept(1),
deny(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The oui filter mode (accept or deny) for the port."
::= { ouiFilterPortEntry 2 }
--------------------
-- DHCP Snoop
--------------------
-- dhcpSnoopPortTable
dhcpSnoopPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpSnoopPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes DHCP snooping enable/disable for each port."
::= { dhcpSnoop 1 }
dhcpSnoopPortEntry OBJECT-TYPE
SYNTAX DhcpSnoopPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dhcpSnoopPortTable."
INDEX { ifIndex }
::= { dhcpSnoopPortTable 1 }
DhcpSnoopPortEntry ::=
SEQUENCE {
dhcpSnoopEnable INTEGER,
dhcpSnoopMaxcnt INTEGER,
dhcpSnoopSmacverifyEnable INTEGER
}
dhcpSnoopEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable DHCP snooping for a port."
::= { dhcpSnoopPortEntry 1 }
dhcpSnoopMaxcnt OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the max entries of the DHCP ARP table."
::= { dhcpSnoopPortEntry 2 }
dhcpSnoopSmacverifyEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable DHCP source MAC verify for a port."
::= { dhcpSnoopPortEntry 3 }
-- dhcpSnoopOperation
dhcpSnoopTarget OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This managed object is used for identify the target on which
the operation should be performed. The target is encoded as:
Byte 1: the octet specifies a set of eight chassis, chassis 0 through 7
Byte 2~3: each octet specifies a set of eight slots, with the
first octet specifying slots 1 through 8 and the second
octet specifying slots 9 through 16.
Byte 4: reserved
Byte 5~11:each octet specifies a set of eight ports, with the first
octet specifying ports 1 through 8, etc."
::= { dhcpSnoop 2 }
dhcpSnoopOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The corresponding bit is set to 1 to start the operation.
The various bit positions are:
BIT 1: DHCP snooping table flush."
::= { dhcpSnoop 3 }
-- dhcpStaticTable
dhcpStaticTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpStaticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines DHCP static IP addresses."
::= { dhcpSnoop 4 }
dhcpStaticEntry OBJECT-TYPE
SYNTAX DhcpStaticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dhcpStaticTable."
INDEX { ifIndex, dhcpStaticIpAddr }
::= { dhcpStaticTable 1 }
DhcpStaticEntry ::=
SEQUENCE {
dhcpStaticIpAddr IpAddress,
dhcpStaticRowStatus RowStatus
}
dhcpStaticIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address which can pass through the port."
::= { dhcpStaticEntry 1 }
dhcpStaticRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status of the table entry."
::= { dhcpStaticEntry 2 }
maxNumOfDhcpStaticIp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of DHCP static IP addresses which can be created for a port."
::= { dhcpSnoop 5 }
dhcpSnoopMaxcntMode OBJECT-TYPE
SYNTAX INTEGER {
replace(1),
drop(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When DHCP snooping table is full, new DHCP lease will replace first one in option 0 or will be dropped in option 1."
::= { dhcpSnoop 6 }
--------------------
-- ACL Rule
--------------------
-- aclSetTable
aclSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF AclSetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"aclsetTable."
::= { acl 1 }
aclSetEntry OBJECT-TYPE
SYNTAX AclSetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of aclSetTable."
INDEX { ifIndex, aclSetVpi, aclSetVci, aclSetProfileName }
::= { aclSetTable 1 }
AclSetEntry ::=
SEQUENCE {
aclSetVpi INTEGER,
aclSetVci INTEGER,
aclSetProfileName DisplayString,
aclSetRowStatus RowStatus
}
aclSetVpi OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VPI value"
::= { aclSetEntry 1 }
aclSetVci OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VCI value"
::= { aclSetEntry 2 }
aclSetProfileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ACL Profile name"
::= { aclSetEntry 3 }
aclSetRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RowStatus of aclSetEntry"
::= { aclSetEntry 4 }
-- aclProfileTable
aclProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF AclProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"aclProfileTable."
::= { acl 2 }
aclProfileEntry OBJECT-TYPE
SYNTAX AclProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of aclProfileTable."
INDEX { aclProfileRuleName }
::= { aclProfileTable 1 }
AclProfileEntry ::=
SEQUENCE {
aclProfileRuleName DisplayString,
aclProfileRuleNumber INTEGER,
aclProfileActionNumber INTEGER,
aclProfileRuleParamMask INTEGER,
aclProfileRuleEtype INTEGER,
aclProfileRuleVid INTEGER,
aclProfileRuleSmac PhysAddress,
aclProfileRuleDmac PhysAddress,
aclProfileRulePriority INTEGER,
aclProfileRuleProtocol INTEGER,
-- aclProfileRuleSrcIP IpAddress,
-- aclProfileRuleSrcIPMask INTEGER,
-- aclProfileRuleDestIP IpAddress,
-- aclProfileRuleDestIPMask INTEGER,
-- aclProfileRuleStartTos INTEGER,
-- aclProfileRuleEndTos INTEGER,
-- aclProfileRuleSrcStartPort INTEGER,
-- aclProfileRuleSrcEndPort INTEGER,
-- aclProfileRuleDestStartPort INTEGER,
-- aclProfileRuleDestEndPort INTEGER,
aclProfileActionRate INTEGER,
aclProfileActionrvlan INTEGER,
aclProfileActionrpri INTEGER,
aclProfileRowStatus RowStatus,
aclProfileRuleSip IpAddress,
aclProfileRuleDip IpAddress,
aclProfileRuleSport INTEGER,
aclProfileRuleDport INTEGER
}
aclProfileRuleName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Profile rule name"
::= { aclProfileEntry 1 }
aclProfileRuleNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The managed object is for acl profile rule configuration.
etype <etype> vlan <vid> (1),
etype <etype> smac <mac> (2),
etype <etype> dmac <mac> (3),
vlan <vid> smac <mac> (4),
vlan <vid> dmac <mac> (5),
smac <mac> dmac <mac> (6),
vlan <vid> priority <priority> (7),
etype <etype> (8),
vlan <vid> (9),
smac <mac> (10),
dmac <mac> (11),
priority <priority> (12),
protocol <protocol> (13),
vlan <vid> sip <ip> (14),
vlan <vid> dip <ip> (15),
vlan <vid> sport tcp|udp <port> (16),
vlan <vid> dport tcp|udp <port> (17) "
::= { aclProfileEntry 2 }
aclProfileActionNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile action number.
Bit 1: rate
Bit 2: rvlan
Bit 3: rpri
Bit 4: deny
Bit 1, Bit 2 & Bit 3 can multiple selection."
::= { aclProfileEntry 3 }
aclProfileRuleParamMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule parameter mask.
BIT 1: srcip <ip>/<mask>
BIT 2: dstip <ip>/<mask>
BIT 3: tos <stos> <etos>
BIT 4: srcport <sport> <eport>
BIT 5: dstport <sport> <eport>"
::= { aclProfileEntry 4 }
aclProfileRuleEtype OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule etype"
::= { aclProfileEntry 5 }
aclProfileRuleVid OBJECT-TYPE
SYNTAX INTEGER (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule vid"
::= { aclProfileEntry 6 }
aclProfileRuleSmac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule source MAC"
::= { aclProfileEntry 7 }
aclProfileRuleDmac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule destination MAC"
::= { aclProfileEntry 8 }
aclProfileRulePriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule priority"
::= { aclProfileEntry 9 }
aclProfileRuleProtocol OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile rule protocol.
icmp(1),igmp(2),ip(4),tcp(6),
udp(17),gre(47),ospf(89),
other ptype"
::= { aclProfileEntry 10 }
-- aclProfileRuleSrcIP OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule source IP"
-- ::= { aclProfileEntry 11 }
--
-- aclProfileRuleSrcIPMask OBJECT-TYPE
-- SYNTAX INTEGER (0..32)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The subnet mask of source IP mask"
-- ::= { aclProfileEntry 12 }
--
-- aclProfileRuleDestIP OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule source IP"
-- ::= { aclProfileEntry 13 }
--
-- aclProfileRuleDestIPMask OBJECT-TYPE
-- SYNTAX INTEGER (0..32)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "The subnet mask of dest IP mask"
-- ::= { aclProfileEntry 14 }
--
-- aclProfileRuleStartTos OBJECT-TYPE
-- SYNTAX INTEGER (0..255)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule start type of service"
-- ::= { aclProfileEntry 15 }
--
-- aclProfileRuleEndTos OBJECT-TYPE
-- SYNTAX INTEGER (0..255)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule end type of service"
-- ::= { aclProfileEntry 16 }
--
-- aclProfileRuleSrcStartPort OBJECT-TYPE
-- SYNTAX INTEGER (0..65535)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule source start port"
-- ::= { aclProfileEntry 17 }
--
-- aclProfileRuleSrcEndPort OBJECT-TYPE
-- SYNTAX INTEGER (0..65535)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule source end port"
-- ::= { aclProfileEntry 18 }
--
-- aclProfileRuleDestStartPort OBJECT-TYPE
-- SYNTAX INTEGER (0..65535)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule destination start port"
-- ::= { aclProfileEntry 19 }
--
-- aclProfileRuleDestEndPort OBJECT-TYPE
-- SYNTAX INTEGER (0..65535)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Profile rule destination end port"
-- ::= { aclProfileEntry 20 }
aclProfileActionRate OBJECT-TYPE
SYNTAX INTEGER (32..65472)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile action to replace to this rate"
::= { aclProfileEntry 21 }
aclProfileActionrvlan OBJECT-TYPE
SYNTAX INTEGER (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile action to replace to this vlan"
::= { aclProfileEntry 22 }
aclProfileActionrpri OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile action to replace to this priority"
::= { aclProfileEntry 23 }
aclProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The row status of the entry."
::= { aclProfileEntry 24 }
aclProfileRuleSip OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source IP."
::= { aclProfileEntry 25 }
aclProfileRuleDip OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination IP."
::= { aclProfileEntry 26 }
aclProfileRuleSport OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source port."
::= { aclProfileEntry 27 }
aclProfileRuleDport OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Destination port."
::= { aclProfileEntry 28 }
--------------------
-- PPPoE Agent
--------------------
-- pppoeAgentTable
pppoeAgentTable OBJECT-TYPE
SYNTAX SEQUENCE OF PppoeAgentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains PPPoE intermediate agent configuration."
::= { pppoeAgent 1 }
pppoeAgentEntry OBJECT-TYPE
SYNTAX PppoeAgentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of pppoeAgentTable."
INDEX { dot1qVlanIndex }
::= { pppoeAgentTable 1 }
PppoeAgentEntry ::=
SEQUENCE {
pppoeAgentEnable INTEGER,
pppoeAgentInfo DisplayString,
pppoeAgentRowStatus RowStatus,
pppoeAgentOptionMode INTEGER
}
pppoeAgentEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable/disable PppoE intermediate agent function."
::= { pppoeAgentEntry 1 }
pppoeAgentInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..23))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User specific Option82 information."
::= { pppoeAgentEntry 2 }
pppoeAgentRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status of the table entry."
::= { pppoeAgentEntry 3 }
pppoeAgentOptionMode OBJECT-TYPE
SYNTAX INTEGER {
private(1),
tr101(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Option82 format."
::= { pppoeAgentEntry 4 }
maxNumOfPppoeAgentConf OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of rows that can be created in pppoeAgentTable."
::= { pppoeAgent 2 }
--------------------
-- n1mac
--------------------
n1macReplaceMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This MAC address will be used to replace client's MAC address."
::= { n1mac 1 }
n1macPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF N1macPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains N to 1 MAC configuration for DSL ports."
::= { n1mac 2 }
n1macPortEntry OBJECT-TYPE
SYNTAX N1macPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of n1macPortTable."
INDEX { ifIndex }
::= { n1macPortTable 1 }
N1macPortEntry ::=
SEQUENCE {
n1macStatusEnable INTEGER
}
n1macStatusEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port status of n1mac function."
::= { n1macPortEntry 1 }
----------------------------------------
-- macff
----------------------------------------
macFfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains MAC Force Forwarding configuration."
::= { macff 1 }
macFfEntry OBJECT-TYPE
SYNTAX MacFfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfTable."
INDEX { macFfIndex }
::= { macFfTable 1 }
MacFfEntry ::=
SEQUENCE {
macFfIndex INTEGER,
macFfVid INTEGER,
macFfArIP IpAddress,
-- macFfArMask INTEGER,
macFfSrcIP IpAddress,
macFfSrcMask INTEGER,
macFfRowStatus RowStatus
}
macFfIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the MACFF."
::= { macFfEntry 1 }
macFfVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VLAN-ID refering to this AR/AS."
::= { macFfEntry 2 }
macFfArIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP of this AR/AS"
::= { macFfEntry 3 }
macFfSrcIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source IP address of the MACFF."
::= { macFfEntry 4 }
macFfSrcMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The subnet mask of source IP mask."
::= { macFfEntry 5 }
macFfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status of the MacFfEntry entry."
::= { macFfEntry 6 }
macFfArpFlush OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the object to 1 to flush mac table."
::= { macff 3 }
maxNumOfMacFfVlanInSystem OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of macff Vlans supported in the system."
::= { macff 4 }
macFfVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains MAC Force Forwarding Vlan configuration."
::= { macff 5 }
macFfVlanEntry OBJECT-TYPE
SYNTAX MacFfVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfVlanTable."
INDEX { dot1qVlanIndex }
::= { macFfVlanTable 1 }
MacFfVlanEntry ::=
SEQUENCE {
macFfVlanRowstatus INTEGER
-- macFfVlanUnknownUnicast INTEGER removed since R3.1
}
macFfVlanRowstatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status of the table used to create/delete an entry."
::= { macFfVlanEntry 1 }
-- removed since R3.1
-- macFfVlanUnknownUnicast OBJECT-TYPE
-- SYNTAX INTEGER {
-- flood(1),
-- drop(2)
-- }
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "Setting downstream unknown uni-cast packet on macff vlan to flooding or dropping."
-- ::= { macFfVlanEntry 2 }
macFfStaticIPTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfStaticIPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" "
::= { macff 6 }
macFfStaticIPEntry OBJECT-TYPE
SYNTAX MacFfStaticIPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfTable."
INDEX { macFfStaticIPPort, macFfStaticIPVid, macFfstaticIP , macFfStaticIPMask}
::= { macFfStaticIPTable 1 }
MacFfStaticIPEntry ::=
SEQUENCE {
macFfStaticIPPort INTEGER,
macFfStaticIPVid INTEGER,
macFfstaticIP IpAddress,
macFfStaticIPMask INTEGER,
macFfStaticIPRowStatus RowStatus
}
macFfStaticIPPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The port number, 1 ~ 48."
::= { macFfStaticIPEntry 1 }
macFfStaticIPVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN ID of the IP range, 1 ~ 4094, the vid should be enable the MACFF function first."
::= { macFfStaticIPEntry 2 }
macFfstaticIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The specified IP range."
::= { macFfStaticIPEntry 3 }
macFfStaticIPMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mask_bits is 24 .. 32."
::= { macFfStaticIPEntry 4 }
macFfStaticIPRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status used to configure the table entry."
::= { macFfStaticIPEntry 5 }
-- Server Mac --
macFfServerMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfServerMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" "
::= { macff 7 }
macFfServerMacEntry OBJECT-TYPE
SYNTAX MacFfServerMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfTable."
INDEX { macFfServerMacVid, macFfServerMacAddr}
::= { macFfServerMacTable 1 }
MacFfServerMacEntry ::=
SEQUENCE {
macFfServerMacVid INTEGER,
macFfServerMacAddr PhysAddress,
macFfServerMacRowStatus RowStatus
}
macFfServerMacVid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN ID of the IP range, 1 ~ 4094, the vid should be enable the MACFF function first."
::= { macFfServerMacEntry 1 }
macFfServerMacAddr OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mac address."
::= { macFfServerMacEntry 2 }
macFfServerMacRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status used to configure the table entry."
::= { macFfServerMacEntry 3 }
----------------------------------------
-- sys
----------------------------------------
timeSetup OBJECT IDENTIFIER ::= { sys 4 }
accessCtrl OBJECT IDENTIFIER ::= { sys 5 }
extAlarm OBJECT IDENTIFIER ::= { sys 8 }
user OBJECT IDENTIFIER ::= { sys 9 }
usbCastCtrl OBJECT IDENTIFIER ::= { sys 10}
dsQos OBJECT IDENTIFIER ::= { sys 11}
stdioTimeout OBJECT-TYPE
SYNTAX INTEGER (0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the CLI/TELNET/WEB Session timeout, 0, or 1~300 minutes, 0 => disable."
::= { sys 12 }
isConfigChanged OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If system configuration has been changed."
::= { sys 13 }
fwUpgrade OBJECT IDENTIFIER ::= {sys 14}
delayedReboot OBJECT IDENTIFIER ::= {sys 15}
--------------------
-- Time Setup
--------------------
-- dayLightSaving
dayLightSaving OBJECT IDENTIFIER ::= { timeSetup 7 }
dayLightSavingAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSaving 1 }
dayLightSavingStartTime OBJECT IDENTIFIER ::= { dayLightSaving 2 }
dayLightSavingStartMonth OBJECT-TYPE
SYNTAX INTEGER {
Jan(1),
Feb(2),
Mar(3),
Apr(4),
May(5),
Jun(6),
Jul(7),
Aug(8),
Sep(9),
Oct(10),
Nov(11),
Dec(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSavingStartTime 1 }
dayLightSavingStartWeek OBJECT-TYPE
SYNTAX INTEGER {
First(1),
Second(2),
Third(3),
Fourth(4),
Last(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSavingStartTime 2 }
dayLightSavingStartWday OBJECT-TYPE
SYNTAX INTEGER {
Sun(1),
Mon(2),
Tus(3),
Wed(4),
Thu(5),
Fri(6),
Sat(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSavingStartTime 3 }
dayLightSavingStartHour OBJECT-TYPE
SYNTAX INTEGER {
"0:00"(0),
"1:00"(1),
"2:00"(2),
"3:00"(3),
"4:00"(4),
"5:00"(5),
"6:00"(6),
"7:00"(7),
"8:00"(8),
"9:00"(9),
"10:00"(10),
"11:00"(11),
"12:00"(12),
"13:00"(13),
"14:00"(14),
"15:00"(15),
"16:00"(16),
"17:00"(17),
"18:00"(18),
"19:00"(19),
"20:00"(20),
"21:00"(21),
"22:00"(22),
"23:00"(23),
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"1: 01:00,
2: 02:00
3: 03:00
4: 04:00
5: 05:00
6: 06:00
7: 07:00
8: 08:00
9: 09:00
10: 10:00
11: 11:00
12: 12:00
13: 13:00
14: 14:00
15: 15:00
16: 16:00
17: 17:00
18: 18:00
19: 19:00
20: 20:00
21: 21:00
22: 22:00
23: 23:00"
::= { dayLightSavingStartTime 4 }
dayLightSavingEndTime OBJECT IDENTIFIER ::= { dayLightSaving 3 }
dayLightSavingEndMonth OBJECT-TYPE
SYNTAX INTEGER {
Jan(1),
Feb(2),
Mar(3),
Apr(4),
May(5),
Jun(6),
Jul(7),
Aug(8),
Sep(9),
Oct(10),
Nov(11),
Dec(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSavingEndTime 1 }
dayLightSavingEndWeek OBJECT-TYPE
SYNTAX INTEGER {
First(1),
Second(2),
Third(3),
Fourth(4),
Last(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSavingEndTime 2 }
dayLightSavingEndWday OBJECT-TYPE
SYNTAX INTEGER {
Sun(1),
Mon(2),
Tus(3),
Wed(4),
Thu(5),
Fri(6),
Sat(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { dayLightSavingEndTime 3 }
dayLightSavingEndHour OBJECT-TYPE
SYNTAX INTEGER {
"0:00"(0),
"1:00"(1),
"2:00"(2),
"3:00"(3),
"4:00"(4),
"5:00"(5),
"6:00"(6),
"7:00"(7),
"8:00"(8),
"9:00"(9),
"10:00"(10),
"11:00"(11),
"12:00"(12),
"13:00"(13),
"14:00"(14),
"15:00"(15),
"16:00"(16),
"17:00"(17),
"18:00"(18),
"19:00"(19),
"20:00"(20),
"21:00"(21),
"22:00"(22),
"23:00"(23),
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"1: 01:00,
2: 02:00
3: 03:00
4: 04:00
5: 05:00
6: 06:00
7: 07:00
8: 08:00
9: 09:00
10: 10:00
11: 11:00
12: 12:00
13: 13:00
14: 14:00
15: 15:00
16: 16:00
17: 17:00
18: 18:00
19: 19:00
20: 20:00
21: 21:00
22: 22:00
23: 23:00"
::= { dayLightSavingEndTime 4 }
--------------------
-- Access Control
--------------------
-- Secured Client Table
securedClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF SecuredClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about secured clients."
::= { accessCtrl 2 }
securedClientEntry OBJECT-TYPE
SYNTAX SecuredClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of secured client entry."
INDEX { securedClientIndex }
::= { securedClientTable 1 }
SecuredClientEntry ::=
SEQUENCE {
securedClientIndex INTEGER,
securedClientStartIp IpAddress,
securedClientEndIp IpAddress,
securedClientService INTEGER,
securedClientEnable INTEGER
}
securedClientIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the entry."
::= { securedClientEntry 1 }
securedClientStartIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The starting IP address of the secured client set."
::= { securedClientEntry 2 }
securedClientEndIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ending IP address of the secured client set."
::= { securedClientEntry 3 }
securedClientService OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Each bit corresponds to a service. The bit is set to 1 if the
service is enabled, and set to 0 if the service is disabled.
The various bit positions are:
BIT 1: telnet
BIT 2: ftp
BIT 3: web
BIT 4: icmp
BIT 5: not support
BIT 6: snmp."
::= { securedClientEntry 4 }
securedClientEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable the entry."
::= { securedClientEntry 5 }
--------------------
-- extAlarm
--------------------
extAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains external alarm information."
::= { extAlarm 1 }
extAlarmEntry OBJECT-TYPE
SYNTAX ExtAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of external alarm table."
INDEX { extAlarmIndex }
::= { extAlarmTable 1 }
ExtAlarmEntry ::=
SEQUENCE {
extAlarmIndex INTEGER,
extAlarmName OCTET STRING,
extAlarmStatus OCTET STRING,
extAlarmTriggeredMode INTEGER
}
extAlarmIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the entry."
::= { extAlarmEntry 1 }
extAlarmName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The external alarm name."
::= { extAlarmEntry 2 }
extAlarmStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Dispaly 'Normal' or 'Alarm' string"
::= { extAlarmEntry 3 }
extAlarmTriggeredMode OBJECT-TYPE
SYNTAX INTEGER {
closeAlarm(1),
openAlarm(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The external alarm triggered mode."
::= { extAlarmEntry 4 }
--------------------
-- User Management
--------------------
userAuthMode OBJECT-TYPE
SYNTAX INTEGER {
local(1),
radius(2),
localThenRadius(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User authentication procsssing mode."
::= { user 1 }
userAuthServerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the authentication server."
::= { user 2 }
userAuthServerPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port of the authentication server."
::= { user 3 }
userAuthServerSecret OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The secret between the authentication server and the NE for authentication process."
::= { user 4 }
-- userTable
userTable OBJECT-TYPE
SYNTAX SEQUENCE OF UserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains user information."
::= { user 5 }
userEntry OBJECT-TYPE
SYNTAX UserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of userTable."
INDEX { userName }
::= { userTable 1 }
UserEntry ::=
SEQUENCE {
userName DisplayString,
userPassword DisplayString,
userPriviledge INTEGER,
userRowStatus RowStatus
}
userName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user name."
::= { userEntry 1 }
userPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The user password."
::= { userEntry 2 }
userPriviledge OBJECT-TYPE
SYNTAX INTEGER {
high(1),
middle(2),
low(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The user priviledge to decide what operation the user can and cannot do."
::= { userEntry 3 }
userRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status used to create or delete a user."
::= { userEntry 4 }
userAuthDefaultPriviledge OBJECT-TYPE
SYNTAX INTEGER {
high(1),
middle(2),
low(3),
deny(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The user default priviledge to be assigned when radius authentication succeds
but no user priviledge information(radius service-type) is provided."
::= { user 6 }
--------------------
-- Upstream Broadcast
--------------------
usBcastCtrlEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable upstream broadcast control."
::= { usbCastCtrl 1 }
usBcastCtrlRate OBJECT-TYPE
SYNTAX INTEGER
UNITS "Kbps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { usbCastCtrl 2 }
--------------------
-- Downstream QoS
--------------------
dsQosEnableMode OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
vlan(2),
dscp(3),
ippre(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable internal overriding mode to VLAN, DSCP or IP Precedence, or disable the overriding mode."
::= { dsQos 1 }
dsQosDefaultPri OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the internal default p.bit after overiding. All values not configured in the
overriding table are assigned to the default p.bit"
::= { dsQos 2 }
dsQoSOverridingTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsQoSOverridingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes downstream QoS overriding information."
::= { dsQos 3 }
dsQoSOverridingEntry OBJECT-TYPE
SYNTAX DsQoSOverridingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in dsQoSOverridingTable."
INDEX { dsQosPriority }
::= { dsQoSOverridingTable 1 }
DsQoSOverridingEntry ::=
SEQUENCE {
dsQosPriority INTEGER,
dsQosValueList DisplayString
}
dsQosPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internal P.bit after overriding."
::= { dsQoSOverridingEntry 1 }
dsQosValueList OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID, DSCP, or IP Precedence based on the internal overriding mode configured.
VLAN ID 1 ~ 4094, DSCP 0 ~ 63, IP Precedence 0 ~ 7. value_list example: <1>, <1,3>, <1,5,6~10>."
::= { dsQoSOverridingEntry 2 }
--------------------
-- fwUpgrade
--------------------
fwUpgradeVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure the target firmware version that will be upgraded."
::= { fwUpgrade 1 }
fwUpgradeCheck OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable firmware upgrade version checking feature."
::= { fwUpgrade 2 }
fwUpgradeStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display current firmware upgrade status."
::= { fwUpgrade 3 }
--------------------
-- delayedReboot
--------------------
delayedRebootTimer OBJECT-TYPE
SYNTAX INTEGER
UNITS "sec"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"5~1800 secs, 0: reboot immediately."
::= { delayedReboot 1 }
delayedRebootRemainingTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "sec"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display the remaining time of scheduled reboot."
::= { delayedReboot 2 }
delayedRebootCancel OBJECT-TYPE
SYNTAX INTEGER {
cancel(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"cancel the scheduled reboot."
::= { delayedReboot 3 }
----------------------------------------
-- statistics
----------------------------------------
dhcpStats OBJECT IDENTIFIER ::= { statistics 11 }
paepvcStats OBJECT IDENTIFIER ::= { statistics 12 }
macStats OBJECT IDENTIFIER ::= { statistics 13 }
-- ipbpvcStats OBJECT IDENTIFIER ::= { statistics 14 }
n1macStats OBJECT IDENTIFIER ::= { statistics 15 }
enetStats OBJECT IDENTIFIER ::= { statistics 16 }
vdslStats OBJECT IDENTIFIER ::= { statistics 17 }
voipStats OBJECT IDENTIFIER ::= { statistics 18 }
macffStats OBJECT IDENTIFIER ::= { statistics 19 }
adslStats OBJECT IDENTIFIER ::= { statistics 20 }
--------------------
-- IGMP
--------------------
igmpQueryCntTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP query messages received."
::= { statistics 1 }
igmpReportCntTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP report messages received."
::= { statistics 2 }
igmpLeaveCntTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP leave messages received."
::= { statistics 3 }
igmpNumOfActiveGroups OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP learned groups."
::= { statistics 4 }
-- igmpGroupTable
igmpGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes igmp group information."
::= { statistics 5 }
igmpGroupEntry OBJECT-TYPE
SYNTAX IgmpGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in igmpGroupTable."
INDEX { igmpGroupIp }
::= { igmpGroupTable 1 }
IgmpGroupEntry ::=
SEQUENCE {
igmpGroupIp IpAddress,
igmpGroupvid INTEGER,
igmpGroupnumberOfMembers INTEGER,
igmpGroupMemberPorts PortList
}
igmpGroupIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"igmp group IP"
::= { igmpGroupEntry 1 }
igmpGroupvid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"vlan id"
::= { igmpGroupEntry 2 }
igmpGroupnumberOfMembers OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"number Of Members"
::= { igmpGroupEntry 3 }
igmpGroupMemberPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Group Member Ports"
::= { igmpGroupEntry 4 }
-- igmpGroupPortTable
igmpGroupPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpGroupPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes igmp Group port information."
::= { statistics 6 }
igmpGroupPortEntry OBJECT-TYPE
SYNTAX IgmpGroupPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in igmpGroupPortTable."
INDEX { ifIndex , igmpGroupPortIp , igmpGroupPortvid}
::= { igmpGroupPortTable 1 }
IgmpGroupPortEntry ::=
SEQUENCE {
igmpGroupPortIp IpAddress,
igmpGroupPortvid INTEGER
}
igmpGroupPortIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Igmp Group IP"
::= { igmpGroupPortEntry 1 }
igmpGroupPortvid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Igmp Group vid"
::= { igmpGroupPortEntry 2 }
-- igmpGroupV2Table
igmpGroupV2Table OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpGroupV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that displays IGMP learned group member information."
::= { statistics 7 }
igmpGroupV2Entry OBJECT-TYPE
SYNTAX IgmpGroupV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of igmpGroupV2Table."
INDEX { igmpGroupV2Vid, igmpGroupV2Ip }
::= { igmpGroupV2Table 1 }
IgmpGroupV2Entry ::=
SEQUENCE {
igmpGroupV2Vid VlanIndex,
igmpGroupV2Ip IpAddress,
igmpGroupV2NumOfMembers INTEGER,
igmpGroupV2MemberPorts PortList
}
igmpGroupV2Vid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IGMP group VLAN ID."
::= { igmpGroupV2Entry 1 }
igmpGroupV2Ip OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The multicast IP address."
::= { igmpGroupV2Entry 2 }
igmpGroupV2NumOfMembers OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of member ports in the group."
::= { igmpGroupV2Entry 3 }
igmpGroupV2MemberPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The member port list of the group."
::= { igmpGroupV2Entry 4 }
-- igmpGroupPortV2Table
igmpGroupPortV2Table OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpGroupPortV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that displays IGMP joined groups in this port."
::= { statistics 8 }
igmpGroupPortV2Entry OBJECT-TYPE
SYNTAX IgmpGroupPortV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of igmpGroupPortV2Table."
INDEX { ifIndex, igmpGroupPortV2Vid, igmpGroupPortV2Ip, igmpGroupPortV2SourceIp }
::= { igmpGroupPortV2Table 1 }
IgmpGroupPortV2Entry ::=
SEQUENCE {
igmpGroupPortV2Vid VlanIndex,
igmpGroupPortV2Ip IpAddress,
igmpGroupPortV2SourceIp IpAddress
}
igmpGroupPortV2Vid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IGMP group VLAN ID."
::= { igmpGroupPortV2Entry 1 }
igmpGroupPortV2Ip OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The multicast IP address."
::= { igmpGroupPortV2Entry 2 }
igmpGroupPortV2SourceIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source IP address that joins the IGMP group."
::= { igmpGroupPortV2Entry 3 }
-- igmpPortCtrlPduTable
igmpPortCtrlPduTable OBJECT-TYPE
SYNTAX SEQUENCE OF IgmpPortCtrlPduEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that displays IGMP related counter values in this port."
::= { statistics 9 }
igmpPortCtrlPduEntry OBJECT-TYPE
SYNTAX IgmpPortCtrlPduEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of igmpPortCtrlPduTable."
INDEX { ifIndex }
::= { igmpPortCtrlPduTable 1 }
IgmpPortCtrlPduEntry ::=
SEQUENCE {
igmpPortCtrlPduQueryCnt Counter32,
igmpPortCtrlPduReportCnt Counter32,
igmpPortCtrlPduLeaveCnt Counter32,
igmpPortNumOfActiveGroups INTEGER,
igmpPortCtrlAuditLeaveCnt Counter32
}
igmpPortCtrlPduQueryCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP query messages received in this port."
::= { igmpPortCtrlPduEntry 1 }
igmpPortCtrlPduReportCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP report messages received in this port."
::= { igmpPortCtrlPduEntry 2 }
igmpPortCtrlPduLeaveCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IGMP leave messages received in this port."
::= { igmpPortCtrlPduEntry 3 }
igmpPortNumOfActiveGroups OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of active IGMP groups in this port."
::= { igmpPortCtrlPduEntry 4 }
igmpPortCtrlAuditLeaveCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of groups left by audit query."
::= { igmpPortCtrlPduEntry 5 }
--------------------
-- vdslStats
--------------------
-- vdslLineStatsTable
vdslLineStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF VdslLineStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table displays VDSL line statistics."
::= { vdslStats 2 }
vdslLineStatsEntry OBJECT-TYPE
SYNTAX VdslLineStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of vdslLineStatsTable."
INDEX { ifIndex }
::= { vdslLineStatsTable 1 }
VdslLineStatsEntry ::=
SEQUENCE {
vdslLineStatsVtucBits1 OCTET STRING,
vdslLineStatsVtucBits2 OCTET STRING,
vdslLineStatsVtucBits3 OCTET STRING,
vdslLineStatsVtucBits4 OCTET STRING,
vdslLineStatsVturBits1 OCTET STRING,
vdslLineStatsVturBits2 OCTET STRING,
vdslLineStatsVturBits3 OCTET STRING,
vdslLineStatsVturBits4 OCTET STRING,
vdslLineStatsVtucGain1 OCTET STRING,
vdslLineStatsVtucGain2 OCTET STRING,
vdslLineStatsVtucGain3 OCTET STRING,
vdslLineStatsVtucGain4 OCTET STRING,
vdslLineStatsVtucGain5 OCTET STRING,
vdslLineStatsVtucGain6 OCTET STRING,
vdslLineStatsVtucGain7 OCTET STRING,
vdslLineStatsVtucGain8 OCTET STRING,
vdslLineStatsVturGain1 OCTET STRING,
vdslLineStatsVturGain2 OCTET STRING,
vdslLineStatsVturGain3 OCTET STRING,
vdslLineStatsVturGain4 OCTET STRING,
vdslLineStatsVturGain5 OCTET STRING,
vdslLineStatsVturGain6 OCTET STRING,
vdslLineStatsVturGain7 OCTET STRING,
vdslLineStatsVturGain8 OCTET STRING,
vdslLineStatsVtucHlog OCTET STRING,
vdslLineStatsVturHlog OCTET STRING,
vdslLineStatsVtucQln OCTET STRING,
vdslLineStatsVturQln OCTET STRING,
vdslLineStatsVtucSnr OCTET STRING,
vdslLineStatsVturSnr OCTET STRING,
vdslLineStatsVtucTssi OCTET STRING,
vdslLineStatsVturTssi OCTET STRING,
vdslLineStatsProtocol INTEGER
}
vdslLineStatsVtucBits1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-C 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 1 }
vdslLineStatsVtucBits2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-C 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 2 }
vdslLineStatsVtucBits3 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-C 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 3 }
vdslLineStatsVtucBits4 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-C 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 4 }
vdslLineStatsVturBits1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-R 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 5 }
vdslLineStatsVturBits2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-R 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 6 }
vdslLineStatsVturBits3 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-R 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 7 }
vdslLineStatsVturBits4 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Bits for the VTU-R 1024 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 15."
::= { vdslLineStatsEntry 8 }
vdslLineStatsVtucGain1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 9 }
vdslLineStatsVtucGain2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 10 }
vdslLineStatsVtucGain3 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 11 }
vdslLineStatsVtucGain4 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 12 }
vdslLineStatsVtucGain5 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 13 }
vdslLineStatsVtucGain6 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 14 }
vdslLineStatsVtucGain7 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 15 }
vdslLineStatsVtucGain8 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 16 }
vdslLineStatsVturGain1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 17 }
vdslLineStatsVturGain2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 18 }
vdslLineStatsVturGain3 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 19 }
vdslLineStatsVturGain4 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 20 }
vdslLineStatsVturGain5 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 21 }
vdslLineStatsVturGain6 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 22 }
vdslLineStatsVturGain7 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 23 }
vdslLineStatsVturGain8 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Gain for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The value is in the range 0 to 4093. Each value in this array is 16 bits wide.
The gain value is represented as a multiple of 1/512 on linear scale."
::= { vdslLineStatsEntry 24 }
vdslLineStatsVtucHlog OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Hlog for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The real Hlog(f) value is represented as (6-m(i)/10), with m(i) in the range 0 to 1022.
A special value m=1023 indicates that no measurement could be done for the
sub-carrier group becauseit is out of the passband or that the attenuation
is out of range to be represented. Each value in this array is 16 bits wide."
::= { vdslLineStatsEntry 25 }
vdslLineStatsVturHlog OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Hlog for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The real Hlog(f) value is represented as (6-m(i)/10), with m(i) in the range 0 to 1022.
A special value m=1023 indicates that no measurement could be done for the
sub-carrier group because it is out of the passband or that the attenuation
is out ofrange to be represented. Each value in this array is 16 bits wide."
::= { vdslLineStatsEntry 26 }
vdslLineStatsVtucQln OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Qln for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
The QLN(f) is represented as ( -23-n(i)/2), with n(i) in the range 0 to 254.
A special value n(i)=255 indicates that no measurement could be done for the
sub-carrier group. Each value in this array is 8 bits wide."
::= { vdslLineStatsEntry 27 }
vdslLineStatsVturQln OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Qln for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
The QLN(f) is represented as ( -23-n(i)/2), with n(i) in the range 0 to 254.
A special value n(i)=255 indicates that no measurement could be done for the
sub-carrier group. Each value in this array is 8 bits wide."
::= { vdslLineStatsEntry 28 }
vdslLineStatsVtucSnr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Snr for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
Octet i is set to a value in the range 0 to 254 (-32 + vdslLineStatsVtucSnr (i)/2) in dB
(i.e., -32 to 95dB). Each value in this array is 8 bits wide."
::= { vdslLineStatsEntry 29 }
vdslLineStatsVturSnr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Snr for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
Octet i is set to a value in the range 0 to 254 (-32 + vdslLineStatsVturSnr (i)/2) in dB
(i.e., -32 to 95dB). Each value in this array is 8 bits wide."
::= { vdslLineStatsEntry 30 }
vdslLineStatsVtucTssi OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Tssi for the VTU-C 512 subcarriers.
Each subcarrier takes two octets to store the value.
Each value in this array is 16 bits wide.
The tssi value is represented as a multiple of 1/32768 on linear scale."
::= { vdslLineStatsEntry 31 }
vdslLineStatsVturTssi OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object provides Tssi for the VTU-R 512 subcarriers.
Each subcarrier takes two octets to store the value.
Each value in this array is 16 bits wide.
The tssi value is represented as a multiple of 1/32768 on linear scale."
::= { vdslLineStatsEntry 32 }
vdslLineStatsProtocol OBJECT-TYPE
SYNTAX INTEGER {
none(1),
vdsl8a(2),
vdsl8b(3),
vdsl8c(4),
vdsl8d(5),
vdsl12a(6),
vdsl12b(7),
vdsl17a(8),
gdmt(9),
glite(10),
adsl2(11),
adsl2plus(12),
t1413(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual line protocol."
::= { vdslLineStatsEntry 33 }
--------------------
-- DHCP
--------------------
-- dhcpSnoopIpTable
dhcpSnoopIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpSnoopIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows the IP addresses and netmasks offered by the DHCP server."
::= { dhcpStats 1 }
dhcpSnoopIpEntry OBJECT-TYPE
SYNTAX DhcpSnoopIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dhcpSnoopIpTable."
INDEX { ifIndex, dhcpSnoopIp }
::= { dhcpSnoopIpTable 1 }
DhcpSnoopIpEntry ::=
SEQUENCE {
dhcpSnoopIp IpAddress,
dhcpSnoopMac PhysAddress,
dhcpSnoopVid VlanIndex,
dhcpSnoopMask INTEGER,
dhcpSnoopGateway IpAddress,
dhcpSnoopRouteMap OCTET STRING
}
dhcpSnoopIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The snooped IP address."
::= { dhcpSnoopIpEntry 1 }
dhcpSnoopMac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The snooped MAC address."
::= { dhcpSnoopIpEntry 2 }
dhcpSnoopVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The snooped VLAN ID."
::= { dhcpSnoopIpEntry 3 }
dhcpSnoopMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The snooped IP mask"
::= { dhcpSnoopIpEntry 4 }
dhcpSnoopGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The snooped Gateway."
::= { dhcpSnoopIpEntry 5 }
dhcpSnoopRouteMap OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The refrence bit map of the dhcp route"
::= { dhcpSnoopIpEntry 6 }
-- dhcpSnoopCounterTable
dhcpSnoopCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpSnoopCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows the DHCP statistics."
::= { dhcpStats 2 }
dhcpSnoopCounterEntry OBJECT-TYPE
SYNTAX DhcpSnoopCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dhcpSnoopCounterTable."
INDEX { ifIndex }
::= { dhcpSnoopCounterTable 1 }
DhcpSnoopCounterEntry ::=
SEQUENCE {
dhcpDiscovery Counter64,
dhcpOffer Counter64,
dhcpRequest Counter64,
dhcpAck Counter64,
dhcpAckBySnoopFull Counter64
}
dhcpDiscovery OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of received DHCP server discovery packets."
::= { dhcpSnoopCounterEntry 1 }
dhcpOffer OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of received DHCP server offer packets."
::= { dhcpSnoopCounterEntry 2 }
dhcpRequest OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of received DHCP IP request packets."
::= { dhcpSnoopCounterEntry 3 }
dhcpAck OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of received DHCP IP acknowledge packets."
::= { dhcpSnoopCounterEntry 4 }
dhcpAckBySnoopFull OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of received DHCP IP acknowledge packets that replace the oldest snooping
entry in snooping table due to table full."
::= { dhcpSnoopCounterEntry 5 }
dhcpRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF DhcpRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains dhcp route information."
::= { dhcpStats 3 }
dhcpRouteEntry OBJECT-TYPE
SYNTAX DhcpRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of dhcpRouteTable."
INDEX { dhcpRouteIndex }
::= { dhcpRouteTable 1 }
DhcpRouteEntry ::=
SEQUENCE {
dhcpRouteIndex INTEGER,
dhcpRouteVid VlanIndex,
dhcpRouteIP IpAddress,
dhcpRouteMask INTEGER,
dhcpRouteGwIP IpAddress
}
dhcpRouteIndex OBJECT-TYPE
SYNTAX INTEGER (1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { dhcpRouteEntry 1 }
dhcpRouteVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN-ID refering to this dhcp route."
::= { dhcpRouteEntry 2 }
dhcpRouteIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP of this dhcp route"
::= { dhcpRouteEntry 3 }
dhcpRouteMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The subnet mask of source IP mask."
::= { dhcpRouteEntry 4 }
dhcpRouteGwIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The gateway IP address."
::= { dhcpRouteEntry 5 }
--------------------
-- PAE PVC
--------------------
-- paepvcSessionTable
paepvcSessionTable OBJECT-TYPE
SYNTAX SEQUENCE OF PaepvcSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows the paepvc session statistics."
::= { paepvcStats 1 }
paepvcSessionEntry OBJECT-TYPE
SYNTAX PaepvcSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of paepvcSessionTable."
INDEX { ifIndex , paepvcSessionVpi, paepvcSessionVci }
::= { paepvcSessionTable 1 }
PaepvcSessionEntry ::=
SEQUENCE {
paepvcSessionVpi INTEGER,
paepvcSessionVci INTEGER,
paepvcSessionState INTEGER,
paepvcSessionId INTEGER,
paepvcSessionUptime Unsigned32,
paepvcSessionacname DisplayString,
paepvcSessionsrvcname DisplayString
}
paepvcSessionVpi OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC VPI."
::= { paepvcSessionEntry 1 }
paepvcSessionVci OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC VCI."
::= { paepvcSessionEntry 2 }
paepvcSessionState OBJECT-TYPE
SYNTAX INTEGER {
down(1),
pppoe(2),
ppp(3),
up(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC status."
::= { paepvcSessionEntry 3 }
paepvcSessionId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC session ID."
::= { paepvcSessionEntry 4 }
paepvcSessionUptime OBJECT-TYPE
SYNTAX Unsigned32
UNITS "second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC session uptime."
::= { paepvcSessionEntry 5 }
paepvcSessionacname OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Access concentrator name."
::= { paepvcSessionEntry 6 }
paepvcSessionsrvcname OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Service name."
::= { paepvcSessionEntry 7 }
-- paepvcCountTable
paepvcCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF PaepvcCountEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows the paepvc counters."
::= { paepvcStats 2 }
paepvcCountEntry OBJECT-TYPE
SYNTAX PaepvcCountEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of paepvcCountTable."
INDEX { ifIndex , paepvcCountVpi, paepvcCountVci }
::= { paepvcCountTable 1 }
PaepvcCountEntry ::=
SEQUENCE {
paepvcCountVpi INTEGER,
paepvcCountVci INTEGER,
paepvcCountPppLcpCfgReqRx Unsigned32,
paepvcCountPppLcpEchoReqRx Unsigned32,
paepvcCountPppLcpEchoReplyRx Unsigned32,
paepvcCountPadiTx Unsigned32,
paepvcCountPadoRx Unsigned32,
paepvcCountPadrTx Unsigned32,
paepvcCountPadsRx Unsigned32,
paepvcCountPadtTx Unsigned32,
paepvcCountPadtRx Unsigned32,
paepvcCountSrvcnameErrRx Unsigned32,
paepvcCountAcSystemErrRx Unsigned32,
paepvcCountGenericErrTx Unsigned32,
paepvcCountGenericErrRx Unsigned32
}
paepvcCountVpi OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC VPI."
::= { paepvcCountEntry 1 }
paepvcCountVci OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PAEPVC VCI."
::= { paepvcCountEntry 2 }
paepvcCountPppLcpCfgReqRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ppp lcp config-request received."
::= { paepvcCountEntry 3 }
paepvcCountPppLcpEchoReqRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ppp lcp echo-request received."
::= { paepvcCountEntry 4 }
paepvcCountPppLcpEchoReplyRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ppp lcp echo-reply received."
::= { paepvcCountEntry 5 }
paepvcCountPadiTx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe padi transfered"
::= { paepvcCountEntry 6 }
paepvcCountPadoRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe pado received"
::= { paepvcCountEntry 7 }
paepvcCountPadrTx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe padr transfered"
::= { paepvcCountEntry 8 }
paepvcCountPadsRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe pads received"
::= { paepvcCountEntry 9 }
paepvcCountPadtTx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe padt transfered"
::= { paepvcCountEntry 10 }
paepvcCountPadtRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe padt received"
::= { paepvcCountEntry 11 }
paepvcCountSrvcnameErrRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe service name error received"
::= { paepvcCountEntry 12 }
paepvcCountAcSystemErrRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe access concentrator name error received"
::= { paepvcCountEntry 13 }
paepvcCountGenericErrTx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe generic error transfered"
::= { paepvcCountEntry 14 }
paepvcCountGenericErrRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of pppoe generic error received"
::= { paepvcCountEntry 15 }
--------------------
-- MAC
--------------------
macDisplayTarget OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This managed object is a filter used for identify the target from which
the MAC addresses are learned in macTable. The target could be:
99: all ports in the system
98: all subscriber ports
97: all Ethernet ports
IfIndex is used for identifying subscriber ports and Ethernet Ports(e.g. 1 ~ 50)."
::= { macStats 1 }
-- macTable
macTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about unicast
entries for which the bridge has forwarding and/or
filtering information. This information is used
by the transparent bridging function in
determining how to propagate a received frame."
::= { macStats 2 }
macEntry OBJECT-TYPE
SYNTAX MacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macTable."
INDEX { dot1qVlanIndex, macAddress }
::= { macTable 1 }
MacEntry ::=
SEQUENCE {
macAddress MacAddress,
macPort INTEGER,
macStatus INTEGER,
macVid VlanIndex
}
macAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unicast MAC address for which the bridge has
forwarding and/or filtering information."
::= { macEntry 1 }
macPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port from which the mac address has been learned."
::= { macEntry 2 }
macStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
learned(3),
self(4),
mgmt(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this entry."
::= { macEntry 3 }
macVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vlan id of this entry."
::= { macEntry 4 }
------------------------------
-- n1macStats
------------------------------
n1macTable OBJECT-TYPE
SYNTAX SEQUENCE OF N1macEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about N to 1
MAC translation, including connection type,
session id/IP and MAC address."
::= { n1macStats 1 }
n1macEntry OBJECT-TYPE
SYNTAX N1macEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of n1macTable."
INDEX { ifIndex, n1macProtoVal}
::= { n1macTable 1 }
N1macEntry ::=
SEQUENCE {
n1macProtoVal Unsigned32,
n1macProtoType INTEGER,
n1macMacAddr MacAddress
}
n1macProtoVal OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protocol value of specified connection. If the connection
is pppoe/pppoaoe, the value stands for session id; if the
connection is ipoe/ipoaoe, the value means IP address."
::= { n1macEntry 1 }
n1macProtoType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ipoe(2),
ipoaoe(3),
pppoe(4),
pppoaoe(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Protocol type of the connection which the MAC is translated."
::= { n1macEntry 2 }
n1macMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The translated MAC address."
::= { n1macEntry 3 }
------------------------------
-- enetStats
------------------------------
enetPrimaryPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" IfIndex is used for identifying the Primary Ethernet Port when dot3ad is disabled."
::= { enetStats 1 }
enetSfpInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnetSfpInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes sfp info of enet port."
::= { enetStats 2 }
enetSfpInfoEntry OBJECT-TYPE
SYNTAX EnetSfpInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in enetSfpInfoTable."
INDEX {ifIndex}
::= { enetSfpInfoTable 1 }
EnetSfpInfoEntry ::=
SEQUENCE {
enetSfpInfoTxpower INTEGER,
enetSfpInfoRxpower INTEGER,
enetSfpInfoTemperature INTEGER,
enetSfpInfoTxBias INTEGER,
enetSfpInfoVoltage INTEGER
}
enetSfpInfoTxpower OBJECT-TYPE
SYNTAX INTEGER (1..65535)
UNITS "10^-4 mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured Tx Output Power."
::= { enetSfpInfoEntry 1 }
enetSfpInfoRxpower OBJECT-TYPE
SYNTAX INTEGER (1..65535)
UNITS "10^-4 C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured Rx Output Power."
::= { enetSfpInfoEntry 2 }
enetSfpInfoTemperature OBJECT-TYPE
SYNTAX INTEGER (-1280000..1280000)
UNITS "10^-4 C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured temperature."
::= { enetSfpInfoEntry 3 }
enetSfpInfoTxBias OBJECT-TYPE
SYNTAX INTEGER (0..131000)
UNITS "10^-3 mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured tx bias."
::= { enetSfpInfoEntry 4 }
enetSfpInfoVoltage OBJECT-TYPE
SYNTAX INTEGER (0..65000)
UNITS "0.1mV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured voltage."
::= { enetSfpInfoEntry 5 }
----------------------------------------
-- macFfStats
----------------------------------------
macFfStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains MAC Force Forwarding static configuration and dynamic information."
::= { macffStats 1 }
macFfStatsEntry OBJECT-TYPE
SYNTAX MacFfStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfStatsTable."
INDEX { macFfStatsIndex }
::= { macFfStatsTable 1 }
MacFfStatsEntry ::=
SEQUENCE {
macFfStatsIndex INTEGER,
macFfStatsVid VlanIndex,
macFfStatsArIP IpAddress,
macFfStatsSrcIP IpAddress,
macFfStatsSrcMask INTEGER
}
macFfStatsIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the MACFF."
::= { macFfStatsEntry 1 }
macFfStatsVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN-ID refering to this AR/AS."
::= { macFfStatsEntry 2 }
macFfStatsArIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP of this AR/AS"
::= { macFfStatsEntry 3 }
macFfStatsSrcIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source IP address of the MACFF."
::= { macFfStatsEntry 4 }
macFfStatsSrcMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The subnet mask of source IP mask."
::= { macFfStatsEntry 5 }
macFfArpTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfArpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains MAC Force Forwarding ARP information."
::= { macffStats 2 }
macFfArpEntry OBJECT-TYPE
SYNTAX MacFfArpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfArpTable."
INDEX { macFfArpVid, macFfArpIP}
::= { macFfArpTable 1 }
MacFfArpEntry ::=
SEQUENCE {
macFfArpVid VlanIndex,
macFfArpIP IpAddress,
macFfArpPort INTEGER,
macFfArpMac PhysAddress
}
macFfArpVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN-ID refering to this AR/AS."
::= { macFfArpEntry 1 }
macFfArpIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP of this AR/AS."
::= { macFfArpEntry 2 }
macFfArpPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port of this AR/AS."
::= { macFfArpEntry 3 }
macFfArpMac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the AR or AS."
::= { macFfArpEntry 4 }
macFfArpCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF MacFfArpCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains MAC Force Forwarding ARP counter information."
::= { macffStats 3 }
macFfArpCounterEntry OBJECT-TYPE
SYNTAX MacFfArpCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of macFfArpCounterTable."
INDEX { ifIndex }
::= { macFfArpCounterTable 1 }
MacFfArpCounterEntry ::=
SEQUENCE {
macFfArpCounterRequestTX Counter32,
macFfArpCounterRequestRX Counter32,
macFfArpCounterRequestRXDrop Counter32,
macFfArpCounterReplyTX Counter32,
macFfArpCounterReplyRX Counter32,
macFfArpCounterReplyRXDrop Counter32
}
macFfArpCounterRequestTX OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ARP Request TX counter."
::= { macFfArpCounterEntry 1 }
macFfArpCounterRequestRX OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ARP Request RX counter."
::= { macFfArpCounterEntry 2 }
macFfArpCounterRequestRXDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ARP Request RX drop counter."
::= { macFfArpCounterEntry 3 }
macFfArpCounterReplyTX OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ARP Reply TX counter."
::= { macFfArpCounterEntry 4 }
macFfArpCounterReplyRX OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ARP Reply RX counter."
::= { macFfArpCounterEntry 5 }
macFfArpCounterReplyRXDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ARP Reply RX drop counter."
::= { macFfArpCounterEntry 6 }
------------------------------
-- adslStats
------------------------------
adslPortUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdslPortUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes adsl port utilization."
::= { adslStats 1 }
adslPortUtilEntry OBJECT-TYPE
SYNTAX AdslPortUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in adslPortUtilEntry."
INDEX {ifIndex}
::= { adslPortUtilTable 1 }
AdslPortUtilEntry ::=
SEQUENCE {
adslPortUtilTx INTEGER,
adslPortUtilRx INTEGER,
adslStatsXturInp DisplayString,
adslStatsXtucInp DisplayString
}
adslPortUtilTx OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measure adsl port's tx utilization."
::= { adslPortUtilEntry 1 }
adslPortUtilRx OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measure adsl port's rx utilization."
::= { adslPortUtilEntry 2 }
adslStatsXturInp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"XTUR minimum INP value."
::= { adslPortUtilEntry 3 }
adslStatsXtucInp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"XTUC minimum INP valu."
::= { adslPortUtilEntry 4 }
----------------------------------------
-- clear
----------------------------------------
counterClearTarget OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This managed object is used for identify the target on which
the counter would be cleared. The target is encoded as:
Byte 1: reserved
Byte 2~3: reserved
Byte 4: reserved
Byte 5~11:each octet specifies a set of eight ports, with the first
octet specifying ports 1 through 8, etc."
::= { clear 1 }
counterClearOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The corresponding bit is set to 1 to start the operation.
The various bit positions are:
BIT 1: clear interface counters
BIT 2: clear pvc packet counters
BIT 3: not support
BIT 4: not support
BIT 5: clear DHCP counters
BIT 6: clear IGMP counters
BIT 7: clear IGMP port counters
BIT 8: not support
BIT 9: clear current lineperf
BIT 10: clear current 15 minute lineperf
BIT 11: clear current 1 day lineperf"
::= { clear 2 }
counterClearVpi OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VPI of the pvc whose counters would be cleared."
::= { clear 3 }
counterClearVci OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VCI of the pvc whose counters would be cleared."
::= { clear 4 }
--------------------
-- VoIP
--------------------
-- voipLineStatusTable
voipLineStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipLineStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table displays VoIP line status."
::= { voipStats 1 }
voipLineStatusEntry OBJECT-TYPE
SYNTAX VoipLineStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of voipLineStatusTable."
INDEX { ifIndex }
::= { voipLineStatusTable 1 }
VoipLineStatusEntry ::=
SEQUENCE {
voipLineStatusPhoneStatus INTEGER,
voipLineStatusServiceStatus INTEGER
}
voipLineStatusPhoneStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
onHook(2),
offHook(3),
ringing(4),
powerCutDown(5),
testing(6),
fault(7),
bad(8),
uninitialized(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Phone status of the line."
::= { voipLineStatusEntry 1 }
voipLineStatusServiceStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
outOfService(2),
idle(3),
waitingForDialing(4),
dialingOut(5),
ringing(6),
conversationCaller(7),
conversationCallee(8),
faxModemCaller(9),
faxModemCallee(10),
waitingForOnHook(11),
dialingTimeout(12),
alertingOffHook(13),
powerCutDown(14)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Service status of the line."
::= { voipLineStatusEntry 2 }
-- voipLineInfoTable
voipLineInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipLineInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table displays VoIP line information."
::= { voipStats 2 }
voipLineInfoEntry OBJECT-TYPE
SYNTAX VoipLineInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of voipLineInfoTable."
INDEX { ifIndex }
::= { voipLineInfoTable 1 }
VoipLineInfoEntry ::=
SEQUENCE {
voipLineInfoSipLocalUri OCTET STRING,
voipLineInfoSipRemoteUri OCTET STRING,
voipLineInfoRtpTxCodecType OCTET STRING,
voipLineInfoRtpRxCodecType OCTET STRING,
voipLineInfoRtpTxPt INTEGER,
voipLineInfoRtpRxPt INTEGER,
voipLineInfoRtpLocalIp IpAddress,
voipLineInfoRtpRemoteIp IpAddress,
voipLineInfoRtpLocalPort INTEGER,
voipLineInfoRtpRemotePort INTEGER,
voipLineInfoSipLocalUri2 OCTET STRING,
voipLineInfoSipRemoteUri2 OCTET STRING,
voipLineInfoRtpTxCodecType2 OCTET STRING,
voipLineInfoRtpRxCodecType2 OCTET STRING,
voipLineInfoRtpTxPt2 INTEGER,
voipLineInfoRtpRxPt2 INTEGER,
voipLineInfoRtpLocalIp2 IpAddress,
voipLineInfoRtpRemoteIp2 IpAddress,
voipLineInfoRtpLocalPort2 INTEGER,
voipLineInfoRtpRemotePort2 INTEGER
}
voipLineInfoSipLocalUri OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 1 }
voipLineInfoSipRemoteUri OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 2 }
voipLineInfoRtpTxCodecType OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 3 }
voipLineInfoRtpRxCodecType OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 4 }
voipLineInfoRtpTxPt OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 5 }
voipLineInfoRtpRxPt OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 6 }
voipLineInfoRtpLocalIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 7 }
voipLineInfoRtpRemoteIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 8 }
voipLineInfoRtpLocalPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 9 }
voipLineInfoRtpRemotePort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 10 }
voipLineInfoSipLocalUri2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 11 }
voipLineInfoSipRemoteUri2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 12 }
voipLineInfoRtpTxCodecType2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 13 }
voipLineInfoRtpRxCodecType2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 14 }
voipLineInfoRtpTxPt2 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 15 }
voipLineInfoRtpRxPt2 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 16 }
voipLineInfoRtpLocalIp2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 17 }
voipLineInfoRtpRemoteIp2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 18 }
voipLineInfoRtpLocalPort2 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 19 }
voipLineInfoRtpRemotePort2 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipLineInfoEntry 20 }
-- voipH248Status
voipH248Status OBJECT IDENTIFIER ::= { voipStats 3 }
voipH248StatusMgName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MG name."
::= { voipH248Status 1 }
voipH248StatusMgStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
registering(2),
registered(3),
unregistering(4),
unregistered(5),
disconnected(6),
disabledByMGC(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mg connection status."
::= { voipH248Status 2 }
-- voipActiveCallStat
voipActiveCallStat OBJECT IDENTIFIER ::= { voipStats 4 }
voipActiveCallStatCurrentActiveCalls OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of current active calls."
::= { voipActiveCallStat 1 }
voipActiveCallStatFailAttempts OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Failed attempts to setup active call."
::= { voipActiveCallStat 2 }
voipActiveCallStatClear OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manager sets the corresponding bit value to 1 to start the operation
and the agent clears the object to zero when the operation is successfully completed.
The various bit positions is:
BIT 1: Clear failed attempts to setup active call."
::= { voipActiveCallStat 3 }
-- voipH248StatusTable
--voipH248StatusTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF VoipH248StatusEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The table displays MG status."
-- ::= { voipStats 3 }
--
--voipH248StatusEntry OBJECT-TYPE
-- SYNTAX VoipH248StatusEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry of voipH248StatusTable."
-- INDEX { VoipH248StatusMgName }
-- ::= { voipH248StatusTable 1 }
--
-- VoipH248StatusEntry ::=
-- SEQUENCE {
-- VoipH248StatusMgName OCTET STRING,
-- VoipH248StatusMgStatus INTEGER
-- }
--
--VoipH248StatusMgName OBJECT-TYPE
-- SYNTAX OCTET STRING
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "MG name."
-- ::= { voipH248StatusEntry 1 }
--
--VoipH248StatusMgStatus OBJECT-TYPE
-- SYNTAX INTEGER {
-- disabled(1),
-- registering(2),
-- registered(3),
-- unregistering(4),
-- unregistered(5),
-- disconnected(6),
-- disabled(7)
-- }
--MAX-ACCESS read-only
--STATUS current
--DESCRIPTION
-- "Mg connection status."
--::= { voipH248StatusEntry 2 }
----------------------------------------
-- voip
----------------------------------------
voipArp OBJECT IDENTIFIER ::= { voip 1 }
voipSip OBJECT IDENTIFIER ::= { voip 2 }
voipIp OBJECT IDENTIFIER ::= { voip 3 }
voipDns OBJECT IDENTIFIER ::= { voip 4 }
voipH248 OBJECT IDENTIFIER ::= { voip 10 }
voipRing OBJECT IDENTIFIER ::= { voip 11 }
voipActiveCall OBJECT IDENTIFIER ::= { voip 13 }
-- voipArpFlushOperation
voipArpFlushOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the object to 1 to start flushing."
::= { voipArp 1 }
-- voipArpShowTable
voipArpShowTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipArpShowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Display ARP entries learnt in specified slot."
::= { voipArp 2 }
voipArpShowEntry OBJECT-TYPE
SYNTAX VoipArpShowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of voipArpShowTable."
INDEX { voipArpShowIp }
::= { voipArpShowTable 1 }
VoipArpShowEntry ::=
SEQUENCE {
voipArpShowIp IpAddress,
voipArpShowMac PhysAddress
}
voipArpShowIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipArpShowEntry 1 }
voipArpShowMac OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipArpShowEntry 2 }
-- voipNumberPlanTable
maxNumOfVoipNumberPlan OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of VoIP number plan supported by the system."
::= { voipSip 1 }
voipNumberPlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipNumberPlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configure numbering plan entry of specified index in specified payphone charging table."
::= { voipSip 2 }
voipNumberPlanEntry OBJECT-TYPE
SYNTAX VoipNumberPlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of voipNumberPlanTable."
INDEX { voipNumberPlanName, voipNumberPlanIndex }
::= { voipNumberPlanTable 1 }
VoipNumberPlanEntry ::=
SEQUENCE {
voipNumberPlanName DisplayString,
voipNumberPlanIndex INTEGER,
voipNumberPlanPattern OCTET STRING,
voipNumberPlanRule OCTET STRING,
voipNumberPlanRowStatus RowStatus
}
voipNumberPlanName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Numbering plan table name."
::= { voipNumberPlanEntry 1 }
voipNumberPlanIndex OBJECT-TYPE
SYNTAX INTEGER (1..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipNumberPlanEntry 2 }
voipNumberPlanPattern OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Allowed characters are 0~9, *, T, S, P, x, ., |
and range format characters that include '~', ','
and parenthesis '(', ')', brackets '[', ']', braces '{', '}'
and at most one parenthesis pair are allowed,
Examples: '002(*)', '0(*)', and '(*)'.
'*' represents one or more digit characters
'x' represents any digit character
'T' timeout send of dial string, can only appear at the end of pattern
'S' star phone key (*) match character in dial plan
'P' pound key (#) match character in dial plan
'.' represents zero or more repetitions of character or range
that precedes it, can't use the dot character '.' in brackets
'|' used to separate multiple number plan patterns
[n~m,k] match a range of digits n~m or a specified digit k,
'[' and ']' must pair and nest brackets is illegal
'~' and ',' are allowed showing in brackets only
'~' connected characters must be digit
{n} match n digits"
::= { voipNumberPlanEntry 3 }
voipNumberPlanRule OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Allowed characters are 0~9, and
'\c' stand for country code,
'\d' stand for national destination code,
'\1' stand for matched string enclosed by the parenthesis pair,
'\n' stand for no local disconnect
'\p' stand for partial pattern
'\t' stand for confirmation tone play
'\tr' stand for recall dial tone play
'deny' stand for the pattern specified is not allowed.
Examples: '\1', '\c\1', and '\c\d\1'."
::= { voipNumberPlanEntry 4 }
voipNumberPlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new entry or delete an existing entry in this table."
::= { voipNumberPlanEntry 5 }
voipNumberPlanDftTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipNumberPlanDftEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configure the action rule after inter-digit timeout in specified entry of numbering plan table."
::= { voipSip 3 }
voipNumberPlanDftEntry OBJECT-TYPE
SYNTAX VoipNumberPlanDftEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of voipNumberDftPlanTable."
INDEX { voipNumberPlanName }
::= { voipNumberPlanDftTable 1 }
VoipNumberPlanDftEntry ::=
SEQUENCE {
voipNumberPlanDftRule OCTET STRING
}
voipNumberPlanDftRule OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Allowed characters are 0~9, and
'\c' stand for country code,
'\d' stand for national destination code,
'\1' stand for matched string enclosed by the parenthesis pair,
'\n' stand for no local disconnect
'\p' stand for partial pattern
'\t' stand for confirmation tone play
'deny' stand for the pattern specified is not allowed.
Examples: '\1', '\c\1', and '\c\d\1'."
::= { voipNumberPlanDftEntry 1 }
digitSetup OBJECT IDENTIFIER ::= { voipSip 4 }
timeoutSetup OBJECT IDENTIFIER ::= {digitSetup 1}
initialTimeout OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"First digit must be dialed before this timeout, 1 ~ 20 seconds."
::= { timeoutSetup 1 }
interDigitTimeout OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If no pattern string is fully matched, the inter-digit timeout will
trigger device to send out current dialed digits, 1 ~ 20 seconds."
::= { timeoutSetup 2 }
digitPauseTimeout OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If a pattern string is end with the T pattern, the pattern string
will not be matched until the timeout happens, 1 ~ 20 seconds."
::= { timeoutSetup 3 }
matchingTimeout OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If a pattern string is fully matched, and there are other pattern
strings partially matched, the pattern string will be sent out if
the timeout happens, 1 ~ 20 seconds."
::= { timeoutSetup 4 }
-- voipIp
voipIpSetIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VoIP's IP address."
::= { voipIp 1 }
voipIpSetVid OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VoIP's VLAN ID."
::= { voipIp 2 }
voipIpSetMask OBJECT-TYPE
SYNTAX INTEGER (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VoIP's network mask."
::= { voipIp 3 }
voipIpSetDhcpClientEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable VoIP's DHCP Client."
::= { voipIp 4 }
voipIpGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP of default VoIP gateway."
::= { voipIp 5 }
-- voipDns
voipDnsIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address."
::= { voipDns 1 }
-- voipRouteTable
maxNumOfVoipRoute OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of VoIP routing entries."
::= { voip 7 }
voipRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { voip 8 }
voipRouteEntry OBJECT-TYPE
SYNTAX VoipRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of voipRouteTable."
INDEX { voipRouteIp, voipRouteGateway, voipRouteMask }
::= { voipRouteTable 1 }
VoipRouteEntry ::=
SEQUENCE {
voipRouteIp IpAddress,
voipRouteGateway IpAddress,
voipRouteMask INTEGER,
voipRouteMetric INTEGER,
voipRouteRowStatus RowStatus
}
voipRouteIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP address."
::= { voipRouteEntry 1 }
voipRouteGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gateway IP."
::= { voipRouteEntry 2 }
voipRouteMask OBJECT-TYPE
SYNTAX INTEGER (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Network mask."
::= { voipRouteEntry 3 }
voipRouteMetric OBJECT-TYPE
SYNTAX INTEGER (1..15)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Metric number of the route."
::= { voipRouteEntry 4 }
voipRouteRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new entry or delete an existing entry in this table."
::= { voipRouteEntry 5 }
-- voipCountryCode
voipCountryCode OBJECT-TYPE
SYNTAX INTEGER {
usa(1)
-- taiwan(2),
-- austria(3),
-- belgium(4),
-- denmark(5),
-- finland(6),
-- netherland(7),
-- norway(8),
-- spain(9),
-- sweden(10),
-- switzerland(11),
-- uk(12),
-- germany(13),
-- australia(14),
-- ireland(15),
-- czech(16),
-- italy(17),
-- japan(18),
-- new_zealand(19),
-- russia(20),
-- china(21),
-- vietnam(22),
-- brazil(23)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure country (information) for VoIP services."
::= { voip 9 }
-- voipH248
maxNumOfVoipH248MgConf OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of virtual media gateway supported by the system."
::= { voipH248 1 }
voipH248MgConf OBJECT IDENTIFIER ::= { voipH248 2 }
voipH248MgName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MG name."
::= { voipH248MgConf 1 }
voipH248MgEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable MG."
::= { voipH248MgConf 2 }
voipH248MgH248Profile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"H248 profile name used by MG."
::= { voipH248MgConf 3 }
voipH248MgPort OBJECT-TYPE
SYNTAX INTEGER (1025..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port number used by MG."
::= { voipH248MgConf 4 }
voipBootRegDelay OBJECT-TYPE
SYNTAX INTEGER (0..30)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Registration delay in seconds."
::= { voip 12}
-- voipRingTable
voipRingTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { voipRing 1 }
voipRingEntry OBJECT-TYPE
SYNTAX VoipRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of voipRouteTable."
INDEX { voipRingIndex }
::= { voipRingTable 1 }
VoipRingEntry ::=
SEQUENCE {
voipRingIndex INTEGER,
voipRingName DisplayString,
voipRingOn1 INTEGER,
voipRingOff1 INTEGER,
voipRingOn2 INTEGER,
voipRingOff2 INTEGER,
voipRingOn3 INTEGER,
voipRingOff3 INTEGER
}
voipRingIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { voipRingEntry 1 }
voipRingName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Ring identifier used in SIP Alert-Info header field"
::= { voipRingEntry 2 }
voipRingOn1 OBJECT-TYPE
SYNTAX INTEGER (100..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"first on time in milliseconds"
::= { voipRingEntry 3 }
voipRingOff1 OBJECT-TYPE
SYNTAX INTEGER (100..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"first off time in milliseconds"
::= { voipRingEntry 4 }
voipRingOn2 OBJECT-TYPE
SYNTAX INTEGER (100..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"second on time in milliseconds"
::= { voipRingEntry 5 }
voipRingOff2 OBJECT-TYPE
SYNTAX INTEGER (100..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"second off time in milliseconds"
::= { voipRingEntry 6 }
voipRingOn3 OBJECT-TYPE
SYNTAX INTEGER (100..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"third on time in milliseconds"
::= { voipRingEntry 7 }
voipRingOff3 OBJECT-TYPE
SYNTAX INTEGER (100..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"third off time in milliseconds"
::= { voipRingEntry 8 }
voipRingSetDefault OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the index to default value."
::= { voipRing 2 }
-- voipActiveCall
voipActiveCallMaxActiveCalls OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure maximum number of concurrent active calls, 0~96."
::= { voipActiveCall 1 }
voipActiveCallThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold to report or clear alarm, 50~100."
::= { voipActiveCall 2 }
-- voipMode
voipMode OBJECT-TYPE
SYNTAX INTEGER {
sip(1),
csip(2),
h248(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure the Mode for VoIP Service."
::= { voip 100 }
-- voipH248MgConfTable
--voipH248MgConfTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF VoipH248MgConfEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table includes H248 MG related configuration."
-- ::= { voipH248 1 }
--
--voipH248MgConfEntry OBJECT-TYPE
-- SYNTAX VoipH248MgConfEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "An entry of voipH248MgConfTable."
-- INDEX { voipH248MgName }
-- ::= { voipH248MgConfTable 1 }
--
--VoipH248MgConfEntry ::=
-- SEQUENCE {
-- voipH248MgName DisplayString,
-- voipH248MgEnable INTEGER,
-- voipH248MgH248Profile DisplayString,
-- voipH248MgPort INTEGER,
-- voipH248MgRowStatus RowStatus
-- }
--
--voipH248MgName OBJECT-TYPE
-- SYNTAX DisplayString
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "MG name."
-- ::= { voipH248MgConfEntry 1 }
--
--voipH248MgEnable OBJECT-TYPE
-- SYNTAX INTEGER {
-- enable(1),
-- disable(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Enable/disable MG."
-- ::= { voipH248MgConfEntry 2 }
--
--voipH248MgH248Profile OBJECT-TYPE
-- SYNTAX DisplayString
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "H248 profile name used by MG."
-- ::= { voipH248MgConfEntry 3 }
--
--voipH248MgPort OBJECT-TYPE
-- SYNTAX INTEGER (1025..65535)
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Port number used by MG."
-- ::= { voipH248MgConfEntry 4 }
--
--voipH248MgRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- MAX-ACCESS read-create
-- STATUS current
-- DESCRIPTION
-- "This object is used to create a new entry or delete an existing entry in this table."
-- ::= { voipH248MgConfEntry 5 }
END