4246 lines
153 KiB
Plaintext
4246 lines
153 KiB
Plaintext
CAMBIUM-PTP800-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
IpAddress, enterprises
|
||
FROM RFC1155-SMI
|
||
OBJECT-TYPE
|
||
FROM RFC-1212
|
||
DisplayString
|
||
FROM RFC1213-MIB
|
||
TRAP-TYPE
|
||
FROM RFC-1215
|
||
InetAddress, InetAddressType
|
||
FROM INET-ADDRESS-MIB;
|
||
|
||
-- Define the Cambium PTP object identifier
|
||
cambium OBJECT IDENTIFIER ::= { enterprises 17713 }
|
||
|
||
-- Groups in cambium
|
||
ptp OBJECT IDENTIFIER ::= { cambium 1 }
|
||
ptmp OBJECT IDENTIFIER ::= { cambium 2 }
|
||
ptp800 OBJECT IDENTIFIER ::= { cambium 8 }
|
||
|
||
-- Groups in ptp800
|
||
bridge OBJECT IDENTIFIER ::= { ptp800 4 }
|
||
configuration OBJECT IDENTIFIER ::= { ptp800 5 }
|
||
ethernet OBJECT IDENTIFIER ::= { ptp800 6 }
|
||
licence OBJECT IDENTIFIER ::= { ptp800 8 }
|
||
management OBJECT IDENTIFIER ::= { ptp800 9 }
|
||
phyControl OBJECT IDENTIFIER ::= { ptp800 10 }
|
||
phyStatus OBJECT IDENTIFIER ::= { ptp800 12 }
|
||
alarms OBJECT IDENTIFIER ::= { ptp800 13 }
|
||
smtp OBJECT IDENTIFIER ::= { ptp800 15 }
|
||
snmpControl OBJECT IDENTIFIER ::= { ptp800 16 }
|
||
sntp OBJECT IDENTIFIER ::= { ptp800 17 }
|
||
reset OBJECT IDENTIFIER ::= { ptp800 18 }
|
||
versions OBJECT IDENTIFIER ::= { ptp800 19 }
|
||
pubStats OBJECT IDENTIFIER ::= { ptp800 20 }
|
||
encryption OBJECT IDENTIFIER ::= { ptp800 22 }
|
||
rfu OBJECT IDENTIFIER ::= { ptp800 23 }
|
||
radioLicense OBJECT IDENTIFIER ::= { ptp800 24 }
|
||
protectionConfig OBJECT IDENTIFIER ::= { ptp800 25 }
|
||
protectionStatus OBJECT IDENTIFIER ::= { ptp800 26 }
|
||
protectionStats OBJECT IDENTIFIER ::= { ptp800 27 }
|
||
aAAControl OBJECT IDENTIFIER ::= { ptp800 29 }
|
||
syslogControl OBJECT IDENTIFIER ::= { ptp800 28 }
|
||
supplementary OBJECT IDENTIFIER ::= { ptp800 96 }
|
||
ptpTraps OBJECT IDENTIFIER ::= { ptp800 99 }
|
||
ptpTrapPrefix OBJECT IDENTIFIER ::= { ptpTraps 0 }
|
||
|
||
|
||
EthernetPriorityTableEntry ::=
|
||
SEQUENCE { ethernetPriorityQueueMapping INTEGER
|
||
, ethernetPriorityTableIndex INTEGER
|
||
}
|
||
|
||
ethernetPriorityTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF EthernetPriorityTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
" A priority queue mapping table. This is a list of packet queues indexed by Ethernet priority."
|
||
::= { ethernet 15 }
|
||
|
||
ethernetPriorityTableEntry OBJECT-TYPE
|
||
SYNTAX EthernetPriorityTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Table EthernetPriorityTable"
|
||
INDEX { ethernetPriorityTableIndex }
|
||
::= { ethernetPriorityTable 1 }
|
||
|
||
L2CPPriorityTableEntry ::=
|
||
SEQUENCE { l2CPPriorityQueueMapping INTEGER
|
||
, l2CPPriorityTableIndex INTEGER
|
||
}
|
||
|
||
l2CPPriorityTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF L2CPPriorityTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
" A priority queue mapping table. This is a list of packet queues associated with the different layer 2 control protocol frameworks."
|
||
::= { ethernet 32 }
|
||
|
||
l2CPPriorityTableEntry OBJECT-TYPE
|
||
SYNTAX L2CPPriorityTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Table L2CPPriorityTable"
|
||
INDEX { l2CPPriorityTableIndex }
|
||
::= { l2CPPriorityTable 1 }
|
||
|
||
IPDSCPPriorityTableEntry ::=
|
||
SEQUENCE { iPDSCPPriorityQueueMapping INTEGER
|
||
, iPDSCPPriorityTableIndex INTEGER
|
||
}
|
||
|
||
iPDSCPPriorityTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF IPDSCPPriorityTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
" A priority queue mapping table. This is a list of packet queues indexed by L3 IP DSCP priority."
|
||
::= { ethernet 38 }
|
||
|
||
iPDSCPPriorityTableEntry OBJECT-TYPE
|
||
SYNTAX IPDSCPPriorityTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Table IPDSCPPriorityTable"
|
||
INDEX { iPDSCPPriorityTableIndex }
|
||
::= { iPDSCPPriorityTable 1 }
|
||
|
||
MPLSTCPriorityTableEntry ::=
|
||
SEQUENCE { mPLSTCPriorityQueueMapping INTEGER
|
||
, mPLSTCPriorityTableIndex INTEGER
|
||
}
|
||
|
||
mPLSTCPriorityTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF MPLSTCPriorityTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
" A priority queue mapping table. This is a list of priority queues indexed by MPLS TC priority."
|
||
::= { ethernet 40 }
|
||
|
||
mPLSTCPriorityTableEntry OBJECT-TYPE
|
||
SYNTAX MPLSTCPriorityTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Table MPLSTCPriorityTable"
|
||
INDEX { mPLSTCPriorityTableIndex }
|
||
::= { mPLSTCPriorityTable 1 }
|
||
|
||
SNMPTrapTableEntry ::=
|
||
SEQUENCE { sNMPTrapTableIndex INTEGER
|
||
, sNMPTrapIPAddress IpAddress
|
||
, sNMPTrapPortNumber INTEGER
|
||
, sNMPTrapInternetAddressType INTEGER
|
||
, sNMPTrapInternetAddress InetAddress
|
||
, sNMPTrapReceiverEnabled INTEGER
|
||
}
|
||
|
||
sNMPTrapTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SNMPTrapTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
" SNMP trap configuration table."
|
||
::= { snmpControl 10 }
|
||
|
||
sNMPTrapTableEntry OBJECT-TYPE
|
||
SYNTAX SNMPTrapTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Table SNMPTrapTable"
|
||
INDEX { sNMPTrapTableIndex }
|
||
::= { sNMPTrapTable 1 }
|
||
|
||
SNTPServerTableEntry ::=
|
||
SEQUENCE { sNTPServerTableIndex INTEGER
|
||
, sNTPServerIPAddress IpAddress
|
||
, sNTPServerPortNumber INTEGER
|
||
, sNTPServerResponse DisplayString
|
||
, sNTPServerInternetAddressType INTEGER
|
||
, sNTPServerInternetAddress InetAddress
|
||
}
|
||
|
||
sNTPServerTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SNTPServerTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
""
|
||
::= { sntp 15 }
|
||
|
||
sNTPServerTableEntry OBJECT-TYPE
|
||
SYNTAX SNTPServerTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Table SNTPServerTable"
|
||
INDEX { sNTPServerTableIndex }
|
||
::= { sNTPServerTable 1 }
|
||
|
||
UserTableEntry ::=
|
||
SEQUENCE { userTableIndex INTEGER
|
||
, userName OCTET STRING
|
||
, userRole INTEGER
|
||
, userEnabled INTEGER
|
||
, userPassword OCTET STRING
|
||
}
|
||
|
||
userTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF UserTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
" The User Table Control group contains objects specifically for user account management."
|
||
::= { aAAControl 2 }
|
||
|
||
userTableEntry OBJECT-TYPE
|
||
SYNTAX UserTableEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Table UserTable"
|
||
INDEX { userTableIndex }
|
||
::= { userTable 1 }
|
||
|
||
-- Bridge group attribute definitions
|
||
--
|
||
localPacketFiltering OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Controls the filtering of Ethernet frames that have been
|
||
sourced from the CMU management agent. When Local Packet
|
||
Filtering is disabled, such frames are transmitted at the
|
||
Wireless Interface and either the Management Port for
|
||
Out-of-Band operation or the Data Port for In-Band
|
||
operation. This is regardless of whether the port has
|
||
been learned for the destination address. When Local
|
||
Packet Filtering is enabled, such frames are only
|
||
transmitted at the port which has been learned for the
|
||
destination address"
|
||
::= { bridge 1 }
|
||
|
||
-- Configuration group attribute definitions
|
||
--
|
||
iPv4Address OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Internet protocol (IPv4) address. This address is used
|
||
by the family of Internet protocols to uniquely identify
|
||
the unit on a network."
|
||
::= { configuration 1 }
|
||
|
||
subnetMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A subnet allows the flow of network traffic between
|
||
hosts to be segregated based on a network configuration.
|
||
By organizing hosts into logical groups, subnetting can
|
||
improve network security and performance"
|
||
::= { configuration 2 }
|
||
|
||
gatewayIPAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The IPv4 address of a device on the current network that
|
||
acts as an IPv4 network gateway. A gateway acts as an
|
||
entrance / exit to packets from / to other networks."
|
||
::= { configuration 3 }
|
||
|
||
maximumTransmitPower OBJECT-TYPE
|
||
SYNTAX INTEGER (-1000..370)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Maximum transmit power the wireless unit is permitted to
|
||
use when establishing and maintaining the wireless link,
|
||
expressed in tenths of a dBm. Note that when an IRFU is
|
||
connected rather than an ODU, the transmit power refers
|
||
to the power at the transceiver output and not the IRFU
|
||
antenna port. See the User Guide for more details"
|
||
::= { configuration 6 }
|
||
|
||
antennaGain OBJECT-TYPE
|
||
SYNTAX INTEGER (0..610)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Antenna Gain. Expressed in 10ths of dBi."
|
||
::= { configuration 7 }
|
||
|
||
rFFeederLoss OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Insertion loss of the microwave connection between the
|
||
RFU and the antenna. The feeder loss should be 0 dB for
|
||
the standard 1 + 0 direct mount configuration. Expressed
|
||
in 10ths of dB."
|
||
::= { configuration 8 }
|
||
|
||
remoteIPAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP Address of the peer wireless unit"
|
||
::= { configuration 12 }
|
||
|
||
remoteMACAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(6))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"MAC Address of the peer wireless unit"
|
||
::= { configuration 13 }
|
||
|
||
enableTransmission OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
enabled(0),
|
||
muted(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Permits the transmitter to radiate. Once the unit is
|
||
installed and configured, use this to enable the
|
||
transmitter"
|
||
::= { configuration 14 }
|
||
|
||
aTPCEnable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Enables Automatic Transmitter Power Control (ATPC).
|
||
NOTE: Use of ATPC is mandatory in some regions. When ATPC
|
||
is enabled, the transmit power is dynamically adjusted to
|
||
optimize link performance. The transmit power will always
|
||
be adjusted within the constraints set by Maximum
|
||
Transmit Power. When ATPC is disabled, the transmit power
|
||
will be fixed at the level set by Maximum Transmit Power.
|
||
When adaptive modulation is enabled, this setting can
|
||
limit the capacity of the system by capping the
|
||
modulation to a mode which is consistent with the
|
||
configured Maximum Transmit Power."
|
||
::= { configuration 15 }
|
||
|
||
iFCableLength OBJECT-TYPE
|
||
SYNTAX INTEGER (0..19000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IF Cable Length in cm - please refer to the user manual
|
||
for more information on the recommended cable type."
|
||
::= { configuration 16 }
|
||
|
||
linkName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name of the PTP link allocated by the System
|
||
Administrator. Used to establish a connection with the
|
||
correct PTP wireless unit at the other end of the link.
|
||
NOTE: The link name MUST be the same at both ends of the
|
||
PTP link."
|
||
::= { configuration 17 }
|
||
|
||
siteName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..63))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This field is allocated by the system administrator and
|
||
contains a description of the site name together with any
|
||
additional notes"
|
||
::= { configuration 18 }
|
||
|
||
diverseAntennaGain OBJECT-TYPE
|
||
SYNTAX INTEGER (0..610)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Diverse Antenna Receive Gain. Expressed in 10ths of
|
||
dBi."
|
||
::= { configuration 19 }
|
||
|
||
diverseRfFeederLoss OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Insertion loss of the microwave connection between the
|
||
RFU and the diverse antenna. Expressed in 10ths of dB."
|
||
::= { configuration 20 }
|
||
|
||
iPv6Address OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..39))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Internet protocol (IPv6) address. This address is used
|
||
by the family of Internet protocols to uniquely identify
|
||
the unit on a network."
|
||
::= { configuration 21 }
|
||
|
||
iPVersion OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ipv4(0),
|
||
ipv6(1),
|
||
dual-ipv4-and-ipv6(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP protocol selection. Choice of IPv4, IPv6 or Dual."
|
||
::= { configuration 22 }
|
||
|
||
iPv6AutoConfiguredLinkLocalAddress OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..39))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The auto configured link local IPv6 address"
|
||
::= { configuration 23 }
|
||
|
||
iPv6PrefixLength OBJECT-TYPE
|
||
SYNTAX INTEGER (0..128)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IPv6 prefix length"
|
||
::= { configuration 24 }
|
||
|
||
iPv6GatewayAddress OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..39))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The IPv6 address of a device on the current network that
|
||
is currently acting as an IPv6 network gateway. A gateway
|
||
acts as an entrance / exit to packets from / to other
|
||
networks."
|
||
::= { configuration 25 }
|
||
|
||
remoteInternetAddressType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(0),
|
||
ipv4(1),
|
||
ipv6(2),
|
||
ipv4z(3),
|
||
ipv6z(4),
|
||
unknown-6(5),
|
||
unknown-7(6),
|
||
unknown-8(7),
|
||
unknown-9(8),
|
||
unknown-10(9),
|
||
unknown-11(10),
|
||
unknown-12(11),
|
||
unknown-13(12),
|
||
unknown-14(13),
|
||
unknown-15(14),
|
||
unknown-16(15),
|
||
dns(16)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of Internet address specified by the associated
|
||
remoteInternetAddressType."
|
||
::= { configuration 26 }
|
||
|
||
remoteInternetAddress OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"INET address used to identify the peer wireless unit"
|
||
::= { configuration 27 }
|
||
|
||
-- Ethernet group attribute definitions
|
||
--
|
||
dataPortCopperAutoNegotiation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This controls whether the configuration of the copper
|
||
data Ethernet interface is automatically negotiated or
|
||
forced. WARNING: ONLY USE FORCED AS A LAST RESORT. To
|
||
operate an Ethernet link at a fixed speed, leave auto
|
||
negotiation enabled and limit the Auto Neg Advertisement
|
||
to the desired speed. Only force Ethernet configuration
|
||
as a last resort if constrained auto negotiation fails.
|
||
NB: Auto-MDI/MDIX is disabled when Forced is set, and the
|
||
unit defaults to MDIX, so the correct straight through or
|
||
crossover cable will be required to establish a
|
||
connection. NB: both ends of an Ethernet link must be
|
||
configured identically, as Forced and auto negotiation
|
||
are NOT compatible. A mixed configuration will cause a
|
||
duplex mismatch"
|
||
::= { ethernet 1 }
|
||
|
||
dataPortCopperAutoNegAdvertisement OBJECT-TYPE
|
||
SYNTAX BITS {
|
||
neg-100-mbps-full-duplex(6),
|
||
neg-1000-mbps-full-duplex(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This sets the different configurations of the copper
|
||
data Ethernet interface that will be advertised during
|
||
auto negotiation. WARNING: Duplex mismatch may result if
|
||
both ends of the Ethernet link do not have the same
|
||
settings. Do not use auto negotiation together with a
|
||
fixed setting at the Ethernet link partner (other end of
|
||
the link). WARNING: Make sure that you select option(s)
|
||
that you know your connected equipment can cater for!"
|
||
::= { ethernet 2 }
|
||
|
||
dataPortStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
down(0),
|
||
copper-link-up(1),
|
||
fiber-link-up(2),
|
||
fiber-y-inactive(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Current status of the data Ethernet link. NB: a change
|
||
of state may generate an SNMP trap and/or SMTP email
|
||
alert"
|
||
::= { ethernet 4 }
|
||
|
||
dataPortSpeedAndDuplex OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
speed1000mbpsfullduplex(0),
|
||
speed100mbpsfullduplex(1),
|
||
unknown(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The current speed and duplex of the data Ethernet link"
|
||
::= { ethernet 5 }
|
||
|
||
dataPortWirelessDownAlert OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When enabled, this causes the data Ethernet link to be
|
||
dropped briefly when the wireless link drops. This is so
|
||
that spanning tree algorithms can quickly detect that
|
||
there is a problem"
|
||
::= { ethernet 6 }
|
||
|
||
useVLANForManagementInterfaces OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no-vlan-tagging(0),
|
||
ieee-8021q-tagged-c-tag-type-8100(1),
|
||
ieee-8021ad-tagged-s-tag-or-b-tag-type-88a8(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This controls whether the management interfaces
|
||
(WWW/SNMP/SMTP/SNTP) use VLAN tags or not"
|
||
::= { ethernet 7 }
|
||
|
||
vLANManagementPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..7)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This VLAN Priority (0-7) will be included in packets
|
||
generated by the management interfaces"
|
||
::= { ethernet 8 }
|
||
|
||
vLANManagementVIDValidation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"If enabled, the management interfaces will only respond
|
||
to Ethernet packets tagged with the configured VLAN
|
||
Management VID, otherwise packets with any VID will be
|
||
accepted"
|
||
::= { ethernet 9 }
|
||
|
||
vLANManagementVID OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4094)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This VLAN VID (0-4094) will be included in packets
|
||
generated by the management interfaces"
|
||
::= { ethernet 11 }
|
||
|
||
ethernetPriorityTableNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (9)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Number of entries in the ethernetPriorityTable."
|
||
::= { ethernet 14 }
|
||
|
||
managementPortAutoNegotiation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This controls whether the configuration of the
|
||
out-of-band management Ethernet interface is
|
||
automatically negotiated or forced. WARNING: ONLY USE
|
||
FORCED AS A LAST RESORT. To operate an Ethernet link at a
|
||
fixed speed, leave auto negotiation enabled and limit the
|
||
Auto Neg Advertisement to the desired speed. Only force
|
||
Ethernet configuration as a last resort if constrained
|
||
auto negotiation fails. NB: Auto-MDI/MDIX is disabled
|
||
when Forced is set, and the unit defaults to MDIX, so the
|
||
correct straight through or crossover cable will be
|
||
required to establish a connection. NB: both ends of an
|
||
Ethernet link must be configured identically, as Forced
|
||
and auto negotiation are NOT compatible. A mixed
|
||
configuration will cause a duplex mismatch"
|
||
::= { ethernet 16 }
|
||
|
||
managementPortAutoNegAdvertisement OBJECT-TYPE
|
||
SYNTAX BITS {
|
||
neg-10-mbps-full-duplex(6),
|
||
neg-100-mbps-full-duplex(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This sets the different configurations of the
|
||
out-of-band management Ethernet interface that will be
|
||
advertised during auto negotiation. WARNING: Duplex
|
||
mismatch may result if both ends of the Ethernet link do
|
||
not have the same settings. Do not use auto negotiation
|
||
together with a fixed setting at the Ethernet link
|
||
partner (other end of the link). WARNING: Make sure that
|
||
you select option(s) that you know your connected
|
||
equipment can cater for!"
|
||
::= { ethernet 17 }
|
||
|
||
managementPortStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
down(0),
|
||
copper-link-up(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Current status of the out-of-band management Ethernet
|
||
link"
|
||
::= { ethernet 18 }
|
||
|
||
managementPortSpeedAndDuplex OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
speed100mbpsfullduplex(1),
|
||
speed10mbpsfullduplex(2),
|
||
unknown(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The current speed and duplex of the out-of-band
|
||
management Ethernet link"
|
||
::= { ethernet 19 }
|
||
|
||
managementPortWirelessDownAlert OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When enabled, this causes the out-of-band management
|
||
Ethernet link to be dropped briefly when the wireless
|
||
link drops. This is so that spanning tree algorithms can
|
||
quickly detect that there is a problem"
|
||
::= { ethernet 20 }
|
||
|
||
managementMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
out-of-band-local(0),
|
||
out-of-band(1),
|
||
in-band(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Management mode: Out-of-band management. End-to-end
|
||
out-of-band mode in which the management agent can be
|
||
reached from the management port at the local CMU, and
|
||
(assuming that the wireless link is established) the
|
||
management port at the remote CMU. Out-of-band local
|
||
management. (default) Similar to the standard out-of-band
|
||
mode, except that management frames are not forwarded
|
||
over the wireless link. In-band management. The
|
||
management agent can be reached from the data port at the
|
||
local CMU, and (assuming that the wireless link is
|
||
established) the data port at the remote CMU. In this
|
||
mode, the management port is disabled."
|
||
::= { ethernet 22 }
|
||
|
||
managementCommittedInformationRate OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
kbps-200(0),
|
||
kbps-300(1),
|
||
kbps-400(2),
|
||
kbps-500(3),
|
||
kbps-600(4),
|
||
kbps-700(5),
|
||
kbps-800(6),
|
||
kbps-900(7),
|
||
kbps-1000(8),
|
||
kbps-1100(9),
|
||
kbps-1200(10),
|
||
kbps-1300(11),
|
||
kbps-1400(12),
|
||
kbps-1500(13),
|
||
kbps-1600(14),
|
||
kbps-1700(15),
|
||
kbps-1800(16),
|
||
kbps-1900(17),
|
||
kbps-2000(18)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The Management Network Committed Information Rate (CIR).
|
||
The Management Network guarantees this capacity will be
|
||
available for management traffic"
|
||
::= { ethernet 23 }
|
||
|
||
dataPortPauseFrames OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
tunnel(0),
|
||
discard(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Controls whether the bridge tunnels or discards Layer 2
|
||
PAUSE frames arriving at the data Ethernet port. Such
|
||
frames are identified by the destination MAC Address
|
||
being equal to 01-80-C2-00-00-01"
|
||
::= { ethernet 24 }
|
||
|
||
transmitCapacityLimit OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Transmit capacity is limited by the lower of: 1) the
|
||
capacity limit specified by the installed License Key. 2)
|
||
the Ethernet speed negotiated at the other end of the
|
||
wireless link. Value expressed in 10ths of Mbps. 0
|
||
indicates unlimited"
|
||
::= { ethernet 26 }
|
||
|
||
transmitCapacityLimitDetail OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
limited-due-to-absence-of-license-key(0),
|
||
running-at-the-capacity-limit(1),
|
||
running-at-unlimited-capacity(2),
|
||
restricted-due-to-remote-ethernet-speed(3),
|
||
limited-due-to-development-override(4),
|
||
unlimited-due-to-development-override(5),
|
||
unlimited-capacity-trial-period(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A brief description of the reason (if any) for the limit
|
||
being applied to the transmit capacity"
|
||
::= { ethernet 27 }
|
||
|
||
dataPortEthernetMediaTypeToUse OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
auto-with-fiber-preference(0),
|
||
force-copper(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The physical media type to use on the data Ethernet port
|
||
"
|
||
::= { ethernet 28 }
|
||
|
||
dataPortCopperForcedConfiguration OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
force-100-mbps-full-duplex(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This forces the configuration of the copper data
|
||
Ethernet interface rather than using auto negotiation.
|
||
THE CONFIGURATION SHOULD ONLY BE FORCED IF YOU ARE HAVING
|
||
PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST ENSURE THAT
|
||
YOU CONFIGURE BOTH THIS UNIT AND THE Ethernet PORT TO
|
||
WHICH IT IS CONNECTED IDENTICALLY! WARNING: Duplex
|
||
mismatch may result if both ends of the Ethernet link do
|
||
not have the same settings. Do not use auto negotiation
|
||
together with a fixed setting at the Ethernet link
|
||
partner (other end of the link)"
|
||
::= { ethernet 29 }
|
||
|
||
managementPortForcedConfiguration OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
force-100-mbps-full-duplex(0),
|
||
force-10-mbps-full-duplex(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This forces the configuration of the out-of-band
|
||
management Ethernet interface rather than using auto
|
||
negotiation. THE CONFIGURATION SHOULD ONLY BE FORCED IF
|
||
YOU ARE HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU
|
||
MUST ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE
|
||
Ethernet PORT TO WHICH IT IS CONNECTED IDENTICALLY!
|
||
WARNING: Duplex mismatch may result if both ends of the
|
||
Ethernet link do not have the same settings. Do not use
|
||
auto negotiation together with a fixed setting at the
|
||
Ethernet link partner (other end of the link)"
|
||
::= { ethernet 30 }
|
||
|
||
l2CPPriorityTableNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (5)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Number of entries in the l2CPPriorityTable."
|
||
::= { ethernet 31 }
|
||
|
||
unknownNetworkPriorityQueueMapping OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
q0(0),
|
||
q1(1),
|
||
q2(2),
|
||
q3(3),
|
||
q4(4),
|
||
q5(5),
|
||
q6(6),
|
||
q7(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Configures the classification of unknown network
|
||
protocols to an egress queue at the wireless port.
|
||
Unknown means something other than IP and MPLS"
|
||
::= { ethernet 33 }
|
||
|
||
dSCPManagementPriority OBJECT-TYPE
|
||
SYNTAX INTEGER (0..63)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This Differentiated Services Code Point value will be
|
||
inserted in the IP Header of all IP Datagrams transmitted
|
||
by the management interfaces"
|
||
::= { ethernet 34 }
|
||
|
||
qOSPriorityScheme OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ethernet(0),
|
||
ipmpls(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Selects classification based on fields in the Ethernet
|
||
header (Layer 2) or in the Network header (Layer 3). The
|
||
unit recognises two network layer protocols: IP and MPLS"
|
||
::= { ethernet 35 }
|
||
|
||
iPDSCPPriorityTableNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (64)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Number of entries in the iPDSCPPriorityTable."
|
||
::= { ethernet 37 }
|
||
|
||
mPLSTCPriorityTableNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (8)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Number of entries in the mPLSTCPriorityTable."
|
||
::= { ethernet 39 }
|
||
|
||
-- EthernetPriorityTable group attribute definitions
|
||
--
|
||
ethernetPriorityQueueMapping OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
q0(0),
|
||
q1(1),
|
||
q2(2),
|
||
q3(3),
|
||
q4(4),
|
||
q5(5),
|
||
q6(6),
|
||
q7(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Configures the classification of this Ethernet priority
|
||
(also known as IEEE 802.1p value) to an egress queue at
|
||
the wireless port."
|
||
::= { ethernetPriorityTableEntry 1 }
|
||
|
||
ethernetPriorityTableIndex OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
p0(1),
|
||
p1(2),
|
||
p2(3),
|
||
p3(4),
|
||
p4(5),
|
||
p5(6),
|
||
p6(7),
|
||
p7(8),
|
||
untagged(9)
|
||
}
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Ethernet priority flag, used to index values in the
|
||
ethernetPriorityTable."
|
||
::= { ethernetPriorityTableEntry 2 }
|
||
|
||
-- L2CPPriorityTable group attribute definitions
|
||
--
|
||
l2CPPriorityQueueMapping OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
q0(0),
|
||
q1(1),
|
||
q2(2),
|
||
q3(3),
|
||
q4(4),
|
||
q5(5),
|
||
q6(6),
|
||
q7(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Configures the classification of this layer two control
|
||
protocol (L2CP) to an egress queue at the wireless port"
|
||
::= { l2CPPriorityTableEntry 1 }
|
||
|
||
l2CPPriorityTableIndex OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
bridge(1),
|
||
garpmrp(2),
|
||
cfm(3),
|
||
r-aps(4),
|
||
eaps(5)
|
||
}
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"layer 2 control protocol, used to index values in the
|
||
l2CPPriorityTable."
|
||
::= { l2CPPriorityTableEntry 2 }
|
||
|
||
-- IPDSCPPriorityTable group attribute definitions
|
||
--
|
||
iPDSCPPriorityQueueMapping OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
q0(0),
|
||
q1(1),
|
||
q2(2),
|
||
q3(3),
|
||
q4(4),
|
||
q5(5),
|
||
q6(6),
|
||
q7(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Configures the classification of this IP differentiated
|
||
services code point (DSCP) value to an egress queue at
|
||
the wireless port"
|
||
::= { iPDSCPPriorityTableEntry 1 }
|
||
|
||
iPDSCPPriorityTableIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..64)
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP DSCP priority flag, used to index values in the
|
||
iPDSCPPriorityTable"
|
||
::= { iPDSCPPriorityTableEntry 2 }
|
||
|
||
-- MPLSTCPriorityTable group attribute definitions
|
||
--
|
||
mPLSTCPriorityQueueMapping OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
q0(0),
|
||
q1(1),
|
||
q2(2),
|
||
q3(3),
|
||
q4(4),
|
||
q5(5),
|
||
q6(6),
|
||
q7(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Configures the classification of this MPLS traffic class
|
||
(the field formerly known as EXP) to an egress queue at
|
||
the wireless port"
|
||
::= { mPLSTCPriorityTableEntry 1 }
|
||
|
||
mPLSTCPriorityTableIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8)
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"MPLS TC priority flag, used to index values in the
|
||
mPLSTCPriorityTable"
|
||
::= { mPLSTCPriorityTableEntry 2 }
|
||
|
||
-- Licence group attribute definitions
|
||
--
|
||
productVariant OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ptp-xx400-full(0),
|
||
ptp-xx400-deprecated-1(1),
|
||
ptp-xx400-deprecated-2(2),
|
||
ptp-xx400-lite(3),
|
||
spare-1(4),
|
||
ptp-xx300(5),
|
||
spare-2(6),
|
||
spare-3(7),
|
||
ptp-xx500-full-deprecated(8),
|
||
ptp-xx500-lite-deprecated(9),
|
||
ptp-xx500(10),
|
||
ptp-xx600-lite(11),
|
||
ptp-xx600-full(12),
|
||
spare-5(13),
|
||
spare-6(14),
|
||
ptp-800(15)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The product variant"
|
||
::= { licence 2 }
|
||
|
||
productName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Name of the product variant"
|
||
::= { licence 3 }
|
||
|
||
ethernetFiberSupport OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Ethernet fiber support availability on this wireless
|
||
unit"
|
||
::= { licence 4 }
|
||
|
||
transmitCapacity OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
rate-10-mbps(0),
|
||
rate-20-mbps(1),
|
||
rate-30-mbps(2),
|
||
rate-40-mbps(3),
|
||
rate-50-mbps(4),
|
||
rate-100-mbps(5),
|
||
rate-150-mbps(6),
|
||
rate-200-mbps(7),
|
||
rate-300-mbps(8),
|
||
rate-unlimited(9)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Maximum capacity the wireless link may provide in the
|
||
transmit direction. This is restricted by the License
|
||
Key."
|
||
::= { licence 10 }
|
||
|
||
encryptionAlgorithmsAvail OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
none(0),
|
||
aes-rijndael(1),
|
||
aes-256-bit-rijndael(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The Encryption Algorithm(s) available to the wireless
|
||
link. N.B. The same Encryption Algorithm must be
|
||
configured at BOTH ends of the link for it to function
|
||
correctly"
|
||
::= { licence 11 }
|
||
|
||
securityLevel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..2)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The maximum configurable security level"
|
||
::= { licence 12 }
|
||
|
||
-- Management group attribute definitions
|
||
--
|
||
linkNameMismatch OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
link-name-mismatch(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Signaling was received with the wrong Link Name. Either
|
||
the Link Name is configured differently at each end of
|
||
the wireless link, or this unit is aligned to the wrong
|
||
link partner. NB: A change of value during operation may
|
||
generate an SNMP trap and/or SMTP email alert"
|
||
::= { management 3 }
|
||
|
||
alignmentMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
normal(0),
|
||
aligning(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Indicates if the unit is undergoing alignment. NB: a
|
||
change of state during operation may generate an SNMP
|
||
trap and/or SMTP email alert"
|
||
::= { management 4 }
|
||
|
||
tFTPServerIPAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP address of the TFTP Server from which the TFTP
|
||
Software Upgrade File Name will be retrieved"
|
||
::= { management 5 }
|
||
|
||
tFTPServerPortNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The port number of the TFTP Server from which the TFTP
|
||
Software Upgrade File Name will be retrieved"
|
||
::= { management 6 }
|
||
|
||
tFTPSoftwareUpgradeFileName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..127))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Filename of the Software Upgrade to be loaded from the
|
||
TFTP Server"
|
||
::= { management 7 }
|
||
|
||
tFTPStartSoftwareUpgrade OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Write '1' to this attribute to start the TFTP software
|
||
upgrade process. The attribute will be reset to 0 when
|
||
the upgrade process has finished"
|
||
::= { management 8 }
|
||
|
||
tFTPSoftwareUpgradeStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
idle(0),
|
||
upload-in-progress(1),
|
||
upload-successful-programming-flash(2),
|
||
upgrade-successful-reboot-to-run-the-new-software-image(3),
|
||
upgrade-failed(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The current status of the TFTP Software upgrade process"
|
||
::= { management 9 }
|
||
|
||
tFTPSoftwareUpgradeStatusText OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..127))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Descriptive text describing the status of the TFTP
|
||
Software upgrade process, including any error details"
|
||
::= { management 10 }
|
||
|
||
tFTPSoftwareUpgradeStatusAdditionalText OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..127))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Any additional text describing the status of the TFTP
|
||
Software upgrade process, including any error details"
|
||
::= { management 11 }
|
||
|
||
hTTPAccessEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(0),
|
||
yes(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This controls whether or not HTTP access is enabled,
|
||
i.e. if this is disabled (0) then the unit will not
|
||
respond to any requests on the HTTP port. Remote
|
||
management via HTTPS is not affected by this setting. Any
|
||
change in this setting will not take effect until the
|
||
unit has been rebooted. (Factory default = Enabled)"
|
||
::= { management 12 }
|
||
|
||
telnetAccessEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(0),
|
||
yes(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This controls whether or not Telnet access is enabled,
|
||
i.e. if this is disabled (0) then the unit will not
|
||
respond to any requests on the TELNET port. Any change in
|
||
this setting will not take effect until the unit has been
|
||
rebooted. (Factory default = Disabled)"
|
||
::= { management 13 }
|
||
|
||
hTTPPortNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This controls the port number for HTTP access. A value
|
||
of zero will use the default port number. Any change in
|
||
this setting will not take effect until the unit has been
|
||
rebooted. (Factory default = 80)"
|
||
::= { management 14 }
|
||
|
||
hTTPSPortNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This controls the port number for HTTPS access. A value
|
||
of zero will use the default port number. Availability of
|
||
HTTPS is controlled via the Licence Key. Any change in
|
||
this setting will not take effect until the unit has been
|
||
rebooted. (Factory default = 443)"
|
||
::= { management 15 }
|
||
|
||
telnetPortNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This controls the port number for TELNET access. A value
|
||
of zero will use the default port number. Any change in
|
||
this setting will not take effect until the unit has been
|
||
rebooted. (Factory default = 23)"
|
||
::= { management 16 }
|
||
|
||
hTTPSAccessEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(0),
|
||
yes(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This controls whether or not HTTPS access is enabled,
|
||
i.e. if this is disabled (0) then the unit will not
|
||
respond to any requests on the configured HTTPS Port
|
||
Number. Remote management via HTTP is not affected by
|
||
this setting. Any change in this setting will not take
|
||
effect until the unit has been rebooted. (Factory default
|
||
= Enabled)"
|
||
::= { management 17 }
|
||
|
||
tFTPServerInternetAddressType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(0),
|
||
ipv4(1),
|
||
ipv6(2),
|
||
ipv4z(3),
|
||
ipv6z(4),
|
||
unknown-6(5),
|
||
unknown-7(6),
|
||
unknown-8(7),
|
||
unknown-9(8),
|
||
unknown-10(9),
|
||
unknown-11(10),
|
||
unknown-12(11),
|
||
unknown-13(12),
|
||
unknown-14(13),
|
||
unknown-15(14),
|
||
unknown-16(15),
|
||
dns(16)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of Internet address specified by the associated
|
||
tFTPServerInternetAddress."
|
||
::= { management 18 }
|
||
|
||
tFTPServerInternetAddress OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"INET address of the TFTP Server from which the TFTP
|
||
Software Upgrade File Name will be retrieved"
|
||
::= { management 19 }
|
||
|
||
-- PhyControl group attribute definitions
|
||
--
|
||
remoteMaximumTransmitPower OBJECT-TYPE
|
||
SYNTAX INTEGER (-1000..370)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Maximum transmit power the remote wireless unit is
|
||
permitted to use when establishing and maintaining the
|
||
wireless link, expressed in tenths of a dBm. Note that
|
||
when an IRFU is connected rather than an ODU, the
|
||
transmit power refers to the power at the transceiver
|
||
output and not the IRFU antenna port. See the User Guide
|
||
for more details"
|
||
::= { phyControl 4 }
|
||
|
||
minModulation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
mod-qpsk(0),
|
||
mod-8psk(1),
|
||
mod-16qam(2),
|
||
mod-32qam(3),
|
||
mod-64qam(4),
|
||
mod-128qam(5),
|
||
mod-256qam(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When adaptive modulation is enabled, PTP 800 will adapt
|
||
the modulation mode between a minimum and maximum
|
||
modulation mode. Depending on the region, minimum and
|
||
maximum modulation modes will be either derived from the
|
||
radio license, e.g. FCC and Industry Canada, or will be
|
||
user adjustable, e.g. ETSI.In general, a modulation mode
|
||
is defined by two aspects, a modulation and a code rate.
|
||
This integer attribute identifies the modulation aspect
|
||
of the minimum modulation mode. For example, if the
|
||
minimum modulation mode is 16QAM 0.91, this attribute
|
||
will be set to a value of 2 which identifies a modulation
|
||
of 16QAM."
|
||
::= { phyControl 6 }
|
||
|
||
minCodeRate OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When adaptive modulation is enabled, PTP 800 will adapt
|
||
the modulation mode between a minimum and maximum
|
||
modulation mode. Depending on the region, minimum and
|
||
maximum modulation modes will be either derived from the
|
||
radio license, e.g. FCC and Industry Canada, or will be
|
||
user adjustable, e.g. ETSI. In general, a modulation mode
|
||
is defined by two aspects, a modulation and a code rate.
|
||
This attribute is equal to 100 times the code rate aspect
|
||
of the minimum modulation mode. For example, if the
|
||
minimum modulation mode is 16QAM 0.91, this attribute
|
||
will be set to a value of 91."
|
||
::= { phyControl 7 }
|
||
|
||
maxModulation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
mod-qpsk(0),
|
||
mod-8psk(1),
|
||
mod-16qam(2),
|
||
mod-32qam(3),
|
||
mod-64qam(4),
|
||
mod-128qam(5),
|
||
mod-256qam(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When adaptive modulation is enabled, PTP 800 will adapt
|
||
the modulation mode between a minimum and maximum
|
||
modulation mode. Depending on the region, minimum and
|
||
maximum modulation modes will be either derived from the
|
||
radio license, e.g. FCC and Industry Canada, or will be
|
||
user adjustable, e.g. ETSI. In general, a modulation mode
|
||
is defined by two aspects, a modulation and a code rate.
|
||
This integer attribute identifies the modulation aspect
|
||
of the maximum modulation mode. For example, if the
|
||
maximum modulation mode is 256QAM 0.91, this attribute
|
||
will be set to a value of 6 which identifies a modulation
|
||
of 256QAM."
|
||
::= { phyControl 8 }
|
||
|
||
maxCodeRate OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When adaptive modulation is enabled, PTP 800 will adapt
|
||
the modulation mode between a minimum and maximum
|
||
modulation mode. Depending on the region, minimum and
|
||
maximum modulation modes will be either derived from the
|
||
radio license, e.g. FCC and Industry Canada, or will be
|
||
user adjustable, e.g. ETSI. In general, a modulation mode
|
||
is defined by two aspects, a modulation and a code rate.
|
||
This attribute is equal to 100 times the code rate aspect
|
||
of the maximum modulation mode. For example, if the
|
||
maximum modulation mode is 256QAM 0.91, this attribute
|
||
will be set to a value of 91."
|
||
::= { phyControl 9 }
|
||
|
||
-- PhyStatus group attribute definitions
|
||
--
|
||
receivePower OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This is the receive power measured by the RFU. When an
|
||
IRFU transceiver is connected rather than an ODU, the
|
||
Receive Power refers to the power at the input to the
|
||
transceiver and not the IRFU antenna port. Expressed in
|
||
tenths of a dBm."
|
||
::= { phyStatus 1 }
|
||
|
||
vectorError OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Vector Error is a measure of received signal quality.
|
||
The value is generally in the range from -6 dB to -38 dB,
|
||
a more negative number indicating a higher quality
|
||
signal. Expressed in tenths of a dB."
|
||
::= { phyStatus 2 }
|
||
|
||
transmitPower OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This is the transmit power of the RFU. When an IRFU
|
||
transceiver is connected rather than an ODU, the Transmit
|
||
Power refers to the power at the transceiver output and
|
||
not the IRFU antenna port. Expressed in tenths of a dBm."
|
||
::= { phyStatus 3 }
|
||
|
||
linkLoss OBJECT-TYPE
|
||
SYNTAX INTEGER (-500..1800)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Link Loss is a measurement of the loss in signal level
|
||
as the radio wave propagates between the antennas
|
||
installed at each end of the link. The Link Loss is only
|
||
accurate if the Antenna Gain and RF Feeder Loss have been
|
||
configured correctly at both ends of the link. Expressed
|
||
in tenths of a dB."
|
||
::= { phyStatus 5 }
|
||
|
||
receiveModulation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
mod-qpsk(0),
|
||
mod-8psk(1),
|
||
mod-16qam(2),
|
||
mod-32qam(3),
|
||
mod-64qam(4),
|
||
mod-128qam(5),
|
||
mod-256qam(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Current active receive modulation"
|
||
::= { phyStatus 8 }
|
||
|
||
transmitModulation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
mod-qpsk(0),
|
||
mod-8psk(1),
|
||
mod-16qam(2),
|
||
mod-32qam(3),
|
||
mod-64qam(4),
|
||
mod-128qam(5),
|
||
mod-256qam(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Current active transmit modulation"
|
||
::= { phyStatus 9 }
|
||
|
||
receiveCodeRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Indicates the code rate applied to the signal being
|
||
received at the wireless interface. The reported value is
|
||
the code rate multiplied by 100."
|
||
::= { phyStatus 16 }
|
||
|
||
transmitCodeRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Indicates the code rate applied to the signal
|
||
transmitted at the wireless interface. The reported value
|
||
is the code rate multiplied by 100."
|
||
::= { phyStatus 17 }
|
||
|
||
-- Alarms group attribute definitions
|
||
--
|
||
unitOutOfCalibration OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
calibrated(0),
|
||
partial-calibration(1),
|
||
invalid-calibration(2),
|
||
bandwidth-variant-unsupported-pas-shutdown(3),
|
||
out-of-calibration-pas-shutdown(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The unit is out of calibration"
|
||
::= { alarms 1 }
|
||
|
||
encryptionEnabledMismatch OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
encryption-enabled-mismatch(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Encryption has been enabled on one end of the wireless
|
||
link but not the other"
|
||
::= { alarms 3 }
|
||
|
||
dataPortDisabledWarning OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
disabled-by-snmp-ifadminstatus(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The SNMP ifAdminStatus of the data Ethernet interface
|
||
has disabled Ethernet traffic"
|
||
::= { alarms 7 }
|
||
|
||
dataPortFiberStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
installed-fiber-not-licensed(1),
|
||
no-fiber-link-established-but-los-not-detected(2),
|
||
no-fiber-link-established-and-los-detected(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"If the fiber interface on the data Ethernet port is not
|
||
OK, there are three possible causes: 1) the fiber
|
||
interface has been installed but disabled, 2) the
|
||
interface could not be established even though no LOS was
|
||
detected (i.e. an optical carrier was detected, which
|
||
could be due to a broken TX fiber, or because the
|
||
interface is disabled at the other end of the fiber
|
||
link), or 3) the interface could not be established and
|
||
LOS is detected (i.e. no optical carrier is detected).
|
||
NB: a change of status may generate an SNMP trap and/or
|
||
SMTP email alert"
|
||
::= { alarms 8 }
|
||
|
||
dataPortConfigurationMismatch OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no-error(0),
|
||
mismatch-detected(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The detection of Ethernet fragments (runt packets) on
|
||
the data Ethernet port when the link is in full duplex is
|
||
an indication of an auto-negotiation or forced
|
||
configuration mismatch"
|
||
::= { alarms 9 }
|
||
|
||
softwareVersionRemoteCompatibility OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
mismatch(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Indicates a mismatch of software versions at the two
|
||
ends of the wireless link"
|
||
::= { alarms 10 }
|
||
|
||
managementPortDisabledWarning OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
disabled-by-snmp-ifadminstatus(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The SNMP ifAdminStatus of the out-of-band management
|
||
Ethernet interface has disabled Ethernet traffic"
|
||
::= { alarms 12 }
|
||
|
||
rFUStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
fault(1),
|
||
unknown-3(2),
|
||
in-reset(3),
|
||
download-in-progress(4),
|
||
incompatible-firmware-version(5),
|
||
incompatible-device(6),
|
||
ifi-card-attached(7),
|
||
no-response(8),
|
||
power-supply-fault(9),
|
||
power-supply-disabled(10),
|
||
switching-memory-banks(11)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Current status of the RFU. A state of 'ok' indicates
|
||
that the RFU is fully operational, although may not be
|
||
transmitting."
|
||
::= { alarms 16 }
|
||
|
||
managementPortConfigurationMismatch OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no-error(0),
|
||
mismatch-detected(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The detection of Ethernet fragments (runt packets) on
|
||
the out-of-band management Ethernet port when the link is
|
||
in full duplex is an indication of an auto-negotiation or
|
||
forced configuration mismatch"
|
||
::= { alarms 17 }
|
||
|
||
secureModeAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
secure-mode-is-active(0),
|
||
secure-mode-is-not-configured(1),
|
||
secure-mode-is-configured-but-not-active(2),
|
||
secure-mode-is-not-supported(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The secure mode (e.g. FIPS, UC-APL) state of the unit.
|
||
The secure mode is not configured(1) state indicates that
|
||
the unit is capable of secure mode operation, and one or
|
||
more of the following security materials has not been
|
||
configured: Key Of Keys, Private Key, Public Certificate,
|
||
DRNG Entropy Status, Wireless Encryption Key. The secure
|
||
mode mode is configured but not active(2) state indicates
|
||
that the unit is capable of secure mode operation, and
|
||
the security material has been configured, but the
|
||
configuration of interfaces is not consistent with secure
|
||
mode operation. The secure mode is not supported(3) state
|
||
indicates that the unit is not capable of secure mode
|
||
operation. The secure mode capability requires
|
||
appropriate hardware compatibility, license key and
|
||
software image."
|
||
::= { alarms 18 }
|
||
|
||
rFUPlatformCompatibility OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
mismatch(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This indicates when the RFU currently connected to the
|
||
CMU does not match the RFU Platform which was installed.
|
||
Either re-run the Installation Wizard or connect the
|
||
correct RFU"
|
||
::= { alarms 19 }
|
||
|
||
rFUProtectionCompatibility OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
mismatch(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This indicates when the IRFU branching unit
|
||
configuration is not compatible with the protection
|
||
configuration or if the left hand transceiver has been
|
||
configured as Secondary or the right hand transceiver has
|
||
been configured as Primary"
|
||
::= { alarms 20 }
|
||
|
||
-- Smtp group attribute definitions
|
||
--
|
||
sMTPEmailAlert OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Simple Mail Transfer Protocol is used to send equipment
|
||
alerts via email to a specified email address. This
|
||
utility can only be configured by the system
|
||
administrator"
|
||
::= { smtp 1 }
|
||
|
||
sMTPServerIPAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IP address of the SMTP server"
|
||
::= { smtp 2 }
|
||
|
||
sMTPServerPortNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Port number of the SMTP server"
|
||
::= { smtp 3 }
|
||
|
||
sMTPSourceEmailAddress OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..63))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The 'from' email address used when constructing the
|
||
automatically generated e-mail message"
|
||
::= { smtp 4 }
|
||
|
||
sMTPDestinationEmailAddress OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..63))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The 'to' email address used when constructing the
|
||
automatically generated e-mail message"
|
||
::= { smtp 5 }
|
||
|
||
sMTPEnabledMessages OBJECT-TYPE
|
||
SYNTAX BITS {
|
||
protection-state(3),
|
||
enabled-diagnostic-alarms(4),
|
||
management-port-up-down(5),
|
||
data-port-up-down(6),
|
||
wireless-link-up-down(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This controls which SMTP messages the unit will send"
|
||
::= { smtp 6 }
|
||
|
||
sMTPServerInternetAddressType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(0),
|
||
ipv4(1),
|
||
ipv6(2),
|
||
ipv4z(3),
|
||
ipv6z(4),
|
||
unknown-6(5),
|
||
unknown-7(6),
|
||
unknown-8(7),
|
||
unknown-9(8),
|
||
unknown-10(9),
|
||
unknown-11(10),
|
||
unknown-12(11),
|
||
unknown-13(12),
|
||
unknown-14(13),
|
||
unknown-15(14),
|
||
unknown-16(15),
|
||
dns(16)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of Internet address specified by the associated
|
||
sMTPServerInternetAddress."
|
||
::= { smtp 7 }
|
||
|
||
sMTPServerInternetAddress OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Internet address of the SMTP server"
|
||
::= { smtp 8 }
|
||
|
||
-- SnmpControl group attribute definitions
|
||
--
|
||
sNMPPortNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The IP port number used to access the SNMP MIB (i.e.
|
||
Gets and Sets). NB: A system reboot is required to
|
||
activate changes to this attribute"
|
||
::= { snmpControl 1 }
|
||
|
||
sNMPCommunityString OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..63))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The SNMP community string. NB: A system reboot is
|
||
required to activate changes to this attribute"
|
||
::= { snmpControl 2 }
|
||
|
||
sNMPTrapVersion OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
v1(0),
|
||
v2c(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The SNMP protocol version to use for SNMP Traps."
|
||
::= { snmpControl 5 }
|
||
|
||
sNMPEnabledTraps OBJECT-TYPE
|
||
SYNTAX BITS {
|
||
protection-state(1),
|
||
authentication-failure(2),
|
||
enabled-diagnostic-alarms(3),
|
||
management-port-up-down(4),
|
||
data-port-up-down(5),
|
||
wireless-link-up-down(6),
|
||
cold-start(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This controls which SNMP Traps the unit will send"
|
||
::= { snmpControl 6 }
|
||
|
||
enabledDiagnosticAlarms OBJECT-TYPE
|
||
SYNTAX BITS {
|
||
data-port-configuration-mismatch(0),
|
||
unknown-7(1),
|
||
wireless-link-status(2),
|
||
sntp-sync(3),
|
||
encryption-enabled-mismatch(4),
|
||
unit-out-of-calibration(5),
|
||
link-name-mismatch(6),
|
||
alignment-mode(7),
|
||
syslog-disabled-warning(8),
|
||
management-port-status(9),
|
||
data-port-status(10),
|
||
rfu-status(11),
|
||
management-port-disabled-warning(12),
|
||
management-port-configuration-mismatch(13),
|
||
data-port-fiber-status(14),
|
||
data-port-disabled-warning(15),
|
||
software-version-mismatch(18),
|
||
syslog-client-disabled-warning(19),
|
||
rfu-power-button-pressed(20),
|
||
secure-mode(21),
|
||
syslog-local-wrapped(22),
|
||
syslog-local-nearly-full(23)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Controls which individual diagnostic alarms are
|
||
enabled."
|
||
::= { snmpControl 7 }
|
||
|
||
enabledDiagnosticProtectionAlarms OBJECT-TYPE
|
||
SYNTAX BITS {
|
||
end-wireless-receive-signal-status(0),
|
||
protection-interface-status(1),
|
||
management-port-ethernet-speed-status(2),
|
||
data-port-ethernet-speed-status(3),
|
||
licensed-transmit-capacity-status(4),
|
||
wireless-receive-signal-status(5),
|
||
protection-configuration-status(6),
|
||
protection-availability-status(7),
|
||
rx-diversity-availability-status(13),
|
||
rx-diversity-configuration-status(14),
|
||
rx-diversity-data-port-status(15)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Controls which individual diagnostic protection alarms
|
||
are enabled."
|
||
::= { snmpControl 8 }
|
||
|
||
sNMPTrapTableNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (2)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Number of entries in the sNMPTrapTable."
|
||
::= { snmpControl 9 }
|
||
|
||
-- SNMPTrapTable group attribute definitions
|
||
--
|
||
sNMPTrapTableIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2)
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"SNMP trap value, used to index the SNMPTrapTable."
|
||
::= { sNMPTrapTableEntry 1 }
|
||
|
||
sNMPTrapIPAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The IP address to which all SNMP Traps are sent. NB: A
|
||
system reboot is required to activate changes to this
|
||
attribute."
|
||
::= { sNMPTrapTableEntry 2 }
|
||
|
||
sNMPTrapPortNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Destination port for SNMP Traps (default=162). NB: A
|
||
system reboot is required to activate changes to this
|
||
attribute."
|
||
::= { sNMPTrapTableEntry 3 }
|
||
|
||
sNMPTrapInternetAddressType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(0),
|
||
ipv4(1),
|
||
ipv6(2),
|
||
ipv4z(3),
|
||
ipv6z(4),
|
||
unknown-6(5),
|
||
unknown-7(6),
|
||
unknown-8(7),
|
||
unknown-9(8),
|
||
unknown-10(9),
|
||
unknown-11(10),
|
||
unknown-12(11),
|
||
unknown-13(12),
|
||
unknown-14(13),
|
||
unknown-15(14),
|
||
unknown-16(15),
|
||
dns(16)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of Internet address specified by the associated
|
||
sNMPTrapInternetAddress."
|
||
::= { sNMPTrapTableEntry 4 }
|
||
|
||
sNMPTrapInternetAddress OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The Internet address to which all SNMP Traps are sent."
|
||
::= { sNMPTrapTableEntry 5 }
|
||
|
||
sNMPTrapReceiverEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A value of 0 disables the sending of SNMP trap to
|
||
corresponding receiver. A value of 1 enables the sending
|
||
of SNMP trap to corresponding receiver."
|
||
::= { sNMPTrapTableEntry 6 }
|
||
|
||
-- Sntp group attribute definitions
|
||
--
|
||
sNTPState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"SNTP control state"
|
||
::= { sntp 1 }
|
||
|
||
sNTPPollInterval OBJECT-TYPE
|
||
SYNTAX INTEGER (60..43200)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The SNTP server polling interval"
|
||
::= { sntp 4 }
|
||
|
||
sNTPSync OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no-sync(0),
|
||
in-sync(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"If SNTP Sync fails then check the server settings in the
|
||
Remote Management page, or disable SNTP. NB: a change of
|
||
state may generate an SNMP trap and/or SMTP email alert"
|
||
::= { sntp 5 }
|
||
|
||
sNTPLastSync OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Last SNTP sync time"
|
||
::= { sntp 6 }
|
||
|
||
systemClock OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"System clock presented as local time"
|
||
::= { sntp 7 }
|
||
|
||
timeZone OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
gmt-minus-1200(0),
|
||
gmt-minus-1130(1),
|
||
gmt-minus-1100(2),
|
||
gmt-minus-1030(3),
|
||
gmt-minus-1000(4),
|
||
gmt-minus-0930(5),
|
||
gmt-minus-0900(6),
|
||
gmt-minus-0830(7),
|
||
gmt-minus-0800(8),
|
||
gmt-minus-0730(9),
|
||
gmt-minus-0700(10),
|
||
gmt-minus-0630(11),
|
||
gmt-minus-0600(12),
|
||
gmt-minus-0530(13),
|
||
gmt-minus-0500(14),
|
||
gmt-minus-0430(15),
|
||
gmt-minus-0400(16),
|
||
gmt-minus-0330(17),
|
||
gmt-minus-0300(18),
|
||
gmt-minus-0230(19),
|
||
gmt-minus-0200(20),
|
||
gmt-minus-0130(21),
|
||
gmt-minus-0100(22),
|
||
gmt-minus-0030(23),
|
||
gmt-zero(24),
|
||
gmt-plus-0030(25),
|
||
gmt-plus-0100(26),
|
||
gmt-plus-0130(27),
|
||
gmt-plus-0200(28),
|
||
gmt-plus-0230(29),
|
||
gmt-plus-0300(30),
|
||
gmt-plus-0330(31),
|
||
gmt-plus-0400(32),
|
||
gmt-plus-0430(33),
|
||
gmt-plus-0500(34),
|
||
gmt-plus-0530(35),
|
||
gmt-plus-0600(36),
|
||
gmt-plus-0630(37),
|
||
gmt-plus-0700(38),
|
||
gmt-plus-0730(39),
|
||
gmt-plus-0800(40),
|
||
gmt-plus-0830(41),
|
||
gmt-plus-0900(42),
|
||
gmt-plus-0930(43),
|
||
gmt-plus-1000(44),
|
||
gmt-plus-1030(45),
|
||
gmt-plus-1100(46),
|
||
gmt-plus-1130(47),
|
||
gmt-plus-1200(48),
|
||
gmt-plus-1230(49),
|
||
gmt-plus-1300(50)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Time zone offsets from Greenwich Mean Time (GMT)"
|
||
::= { sntp 8 }
|
||
|
||
daylightSaving OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Daylight Saving Time"
|
||
::= { sntp 9 }
|
||
|
||
sNTPPrimaryServer OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
server-1(0),
|
||
server-2(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Specifies the primary SNTP server, determining the order
|
||
in which the servers are tried."
|
||
::= { sntp 10 }
|
||
|
||
sNTPPrimaryServerDeadTime OBJECT-TYPE
|
||
SYNTAX INTEGER (0..86400)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Time (in seconds) to wait before retrying communications
|
||
with an unresponsive primary SNTP server. Setting the
|
||
value to 0 disables the timer."
|
||
::= { sntp 11 }
|
||
|
||
sNTPServerRetries OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Number of times the PTP will retry after an SNTP server
|
||
fails to respond."
|
||
::= { sntp 12 }
|
||
|
||
sNTPServerTimeout OBJECT-TYPE
|
||
SYNTAX INTEGER (1..15)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Time (in seconds) the PTP will wait for a response from
|
||
an SNTP server."
|
||
::= { sntp 13 }
|
||
|
||
sNTPServerTableNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (2)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Number of entries in the SNTPServerTable."
|
||
::= { sntp 14 }
|
||
|
||
-- SNTPServerTable group attribute definitions
|
||
--
|
||
sNTPServerTableIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2)
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Index range for the SNTPServerTable."
|
||
::= { sNTPServerTableEntry 1 }
|
||
|
||
sNTPServerIPAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The IP address of a valid SNTP server"
|
||
::= { sNTPServerTableEntry 2 }
|
||
|
||
sNTPServerPortNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The IP port number of the SNTP server. Defaults to port
|
||
123."
|
||
::= { sNTPServerTableEntry 3 }
|
||
|
||
sNTPServerResponse OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..127))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The most recent response received from the SNTP server,
|
||
if used"
|
||
::= { sNTPServerTableEntry 4 }
|
||
|
||
sNTPServerInternetAddressType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(0),
|
||
ipv4(1),
|
||
ipv6(2),
|
||
ipv4z(3),
|
||
ipv6z(4),
|
||
unknown-6(5),
|
||
unknown-7(6),
|
||
unknown-8(7),
|
||
unknown-9(8),
|
||
unknown-10(9),
|
||
unknown-11(10),
|
||
unknown-12(11),
|
||
unknown-13(12),
|
||
unknown-14(13),
|
||
unknown-15(14),
|
||
unknown-16(15),
|
||
dns(16)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of Internet address specified by the associated
|
||
sNTPServerInternetAddress."
|
||
::= { sNTPServerTableEntry 5 }
|
||
|
||
sNTPServerInternetAddress OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The Internet address of a valid SNTP server"
|
||
::= { sNTPServerTableEntry 6 }
|
||
|
||
-- Reset group attribute definitions
|
||
--
|
||
systemReset OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
running(0),
|
||
console-reboot(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Setting this attribute to '1' will cause a system
|
||
reboot. NB: a system reboot will apply any pending new
|
||
settings held in memory"
|
||
::= { reset 1 }
|
||
|
||
-- Versions group attribute definitions
|
||
--
|
||
softwareVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Current software version"
|
||
::= { versions 1 }
|
||
|
||
hardwareVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Hardware platform version"
|
||
::= { versions 2 }
|
||
|
||
secondarySoftwareVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Secondary software version, used when the primary
|
||
software image is invalid or erased"
|
||
::= { versions 3 }
|
||
|
||
bootVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Boot code software version"
|
||
::= { versions 4 }
|
||
|
||
-- PubStats group attribute definitions
|
||
--
|
||
receiveDataRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Data rate received by the wireless interface. Expressed
|
||
in kbps, rounded down to nearest 100 kbps."
|
||
::= { pubStats 1 }
|
||
|
||
transmitDataRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Data rate transmitted from the wireless interface.
|
||
Expressed in kbps, rounded down to nearest 100 kbps."
|
||
::= { pubStats 2 }
|
||
|
||
aggregateDataRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Total data rate across the wireless interface summed
|
||
over both link directions. Expressed in kbps, rounded
|
||
down to nearest 100 kbps."
|
||
::= { pubStats 3 }
|
||
|
||
wirelessLinkAvailability OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1000000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The percentage of time that the unit has been able to
|
||
successfully demodulate the signal transmitted from the
|
||
remote end of the link. Calculated since the last reset
|
||
of the system counters. The reported value is the
|
||
percentage multiplied by 10000."
|
||
::= { pubStats 4 }
|
||
|
||
wirelessLinkStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
up(0),
|
||
registering(1),
|
||
searching(2),
|
||
acquiring(3),
|
||
radar-cac(4),
|
||
initialising(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Current status of the wireless link"
|
||
::= { pubStats 5 }
|
||
|
||
-- Encryption group attribute definitions
|
||
--
|
||
encryptionAlgorithm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
none(0),
|
||
aes-rijndael(1),
|
||
aes-256-bit-rijndael(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The Encryption Algorithm used by the wireless link. NB:
|
||
A system reboot is required to activate changes to this
|
||
attribute. NB: The same Encryption Algorithm must be
|
||
configured at BOTH ends of the link for it to function
|
||
correctly"
|
||
::= { encryption 1 }
|
||
|
||
-- Rfu group attribute definitions
|
||
--
|
||
rFURfBand OBJECT-TYPE
|
||
SYNTAX INTEGER (4000..70000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU RF band in MHz"
|
||
::= { rfu 1 }
|
||
|
||
rFUTxBandAboveRx OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(0),
|
||
yes(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Yes means RFU transmitter frequency band is above
|
||
receiver frequency band"
|
||
::= { rfu 2 }
|
||
|
||
rFUFreqSpacing OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1560000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Tx-Rx frequency spacing in kHz"
|
||
::= { rfu 3 }
|
||
|
||
rFUTxPowerMin OBJECT-TYPE
|
||
SYNTAX INTEGER (-100..100)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Minimum transmitter power level, in 10ths of dBm"
|
||
::= { rfu 4 }
|
||
|
||
rFUTxPowerMax OBJECT-TYPE
|
||
SYNTAX INTEGER (160..370)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Maximum transmitter power level, in 10ths of dBm"
|
||
::= { rfu 5 }
|
||
|
||
rFURxFreqMin OBJECT-TYPE
|
||
SYNTAX INTEGER (5725000..70000000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Minimum receiver frequency in kHz"
|
||
::= { rfu 6 }
|
||
|
||
rFURxFreqMax OBJECT-TYPE
|
||
SYNTAX INTEGER (5725000..70000000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Maximum receiver frequency in kHz"
|
||
::= { rfu 7 }
|
||
|
||
rFUTxFreqMin OBJECT-TYPE
|
||
SYNTAX INTEGER (5725000..70000000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Minimum transmitter frequency in kHz"
|
||
::= { rfu 8 }
|
||
|
||
rFUTxFreqMax OBJECT-TYPE
|
||
SYNTAX INTEGER (5725000..70000000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Maximum transmitter frequency in kHz"
|
||
::= { rfu 9 }
|
||
|
||
rFUSerial OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..11))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU serial number"
|
||
::= { rfu 10 }
|
||
|
||
rFUActiveFirmwareBank OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU active firmware bank number"
|
||
::= { rfu 11 }
|
||
|
||
rFUVersionBank1 OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..11))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU firmware version number (nnn/ddMMYY) in bank 1"
|
||
::= { rfu 12 }
|
||
|
||
rFUVersionBank2 OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..11))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU firmware version number (nnn/ddMMYY) in bank 2"
|
||
::= { rfu 13 }
|
||
|
||
rFUType OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..79))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU type as: RFU platform, frequency band, Tx-Rx
|
||
frequency spacing, Hi/Lo band and transmit frequency
|
||
range"
|
||
::= { rfu 14 }
|
||
|
||
rFURxRFSynthLockAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
out-of-lock(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU RF receiver out of lock alarm"
|
||
::= { rfu 15 }
|
||
|
||
rFUTxRFSynthLockAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
out-of-lock(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU RF transmitter out of lock alarm"
|
||
::= { rfu 16 }
|
||
|
||
rFUTxPowerAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
tx-output-failed(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU transmitter output failed alarm"
|
||
::= { rfu 17 }
|
||
|
||
rFUCommonIFSynthLockAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
out-of-lock(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm indicating when the common IF RFU synthesizer is
|
||
out of lock"
|
||
::= { rfu 18 }
|
||
|
||
rFUPowerAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
power-failed(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU general power alarm"
|
||
::= { rfu 19 }
|
||
|
||
rFULockoutAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
locked-out(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU locked pending unlock code alarm"
|
||
::= { rfu 20 }
|
||
|
||
rFUCableAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
if-cable-voltage-out-of-range(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU cable detector voltage out of range alarm"
|
||
::= { rfu 21 }
|
||
|
||
rFUCableAttenuationAdjustAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
if-cable-attenuator-adjusting(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU cable attenuator not yet adjusted alarm"
|
||
::= { rfu 22 }
|
||
|
||
rFUTxPowerDegradedAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
degraded(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Indicates when the current transmit power is more than 3
|
||
dB below or more than 3 dB above the correct transmit
|
||
power."
|
||
::= { rfu 23 }
|
||
|
||
rFURpsAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
rps-alarm-active(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU radio protection switch (RPS) alarm"
|
||
::= { rfu 24 }
|
||
|
||
rFUTxMuteStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
transmitting(0),
|
||
muted-by-user(1),
|
||
muted-due-to-configuration-error(2),
|
||
muted-due-to-rfu-fault(3),
|
||
muted-due-to-rfu-configuring(4),
|
||
muted-due-to-rfu-incompatible-with-cmu(5),
|
||
muted-due-to-inactive(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Indicates whether the RFU is transmitting or muted. If
|
||
it is muted, it will also indicate the reason."
|
||
::= { rfu 25 }
|
||
|
||
rFUFanAssemblyAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
partial-fan-failure(1),
|
||
total-fan-failure(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This indicates when the IRFU transceiver fan assembly
|
||
has failed. The assembly consists of two fans and if one
|
||
fan fails, the this will report partial failure. If both
|
||
fans fail, this will report total failure"
|
||
::= { rfu 26 }
|
||
|
||
rFUHighTemperatureAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
high-temperature(1),
|
||
very-high-temperature(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Indicates when the temperature of the IRFU transceiver
|
||
has risen above either of two thresholds. If the
|
||
temperature exceeds the High Temperature threshold, the
|
||
transmit power may reduce. If the temperature exceeds the
|
||
Very High Temperature threshold, the transceiver will
|
||
mute the transmitter"
|
||
::= { rfu 27 }
|
||
|
||
rFURFSwitchAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
fault(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This indicates that an RF switch is not present when it
|
||
should be or that on the most recent attempt to make this
|
||
unit active, the IRFU RF Switch was not able to switch to
|
||
the correct position"
|
||
::= { rfu 28 }
|
||
|
||
rFURxIFSynthLockAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
out-of-lock(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU IF receiver out of lock alarm"
|
||
::= { rfu 29 }
|
||
|
||
rFUTxIFSynthLockAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
out-of-lock(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"RFU IF transmitter out of lock alarm"
|
||
::= { rfu 30 }
|
||
|
||
rFUPowerButtonPressed OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
irfu-power-button-was-pressed(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"IRFU power button have been pressed, IFRU has powered
|
||
down unexpectedly"
|
||
::= { rfu 31 }
|
||
|
||
rFUConnectedPlatform OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(0),
|
||
odu-a(1),
|
||
odu-b(2),
|
||
irfu-hp(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of RFU platform currently connected to the CMU"
|
||
::= { rfu 32 }
|
||
|
||
rFUCommonRFSynthLockAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
out-of-lock(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Alarm indicating when the common RFU RF synthesizer is
|
||
out of lock"
|
||
::= { rfu 33 }
|
||
|
||
rFUBranchingConfiguration OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
rfu-1plus0(0),
|
||
rfu-1plus0-mhsb-ready-equal(1),
|
||
rfu-1plus0-mhsb-ready-unequal(2),
|
||
rfu-1plus1-mhsb-equal(3),
|
||
rfu-1plus1-mhsb-unequal(4),
|
||
rfu-1plus1-tx-mhsb--rx-sd(5),
|
||
rfu-2plus0(6)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When an IRFU is being installed, the configuration of
|
||
the IRFU branching unit must be configured. Please see
|
||
the User Guide for further details"
|
||
::= { rfu 34 }
|
||
|
||
rFUTransceiverLocation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
left-trx-a(0),
|
||
right-trx-b(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When a 2+0 IRFU is being installed, the user must
|
||
configure which of the two IRFU transceivers the CMU is
|
||
controlling in order to ensure correct operation"
|
||
::= { rfu 35 }
|
||
|
||
rFURfSwitchCableAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
fault(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The RF switch in the IRFU is indicating an invalid
|
||
switch position. The most likely cause is a fault or a
|
||
disconnection of the cable which connects the transceiver
|
||
to the RF switch"
|
||
::= { rfu 36 }
|
||
|
||
rFUReceiveBranchingUnitLoss OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The receive loss in the IRFU branching unit, expressed
|
||
in tenths of a dB. The branching unit is a component of
|
||
the IRFU which is situated between the IRFU transceiver
|
||
and IRFU antenna port. It provides the necessary
|
||
filtering, isolation and coupling."
|
||
::= { rfu 37 }
|
||
|
||
rFUTransmitBranchingUnitLoss OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The transmit loss in the IRFU branching unit, expressed
|
||
in tenths of a dB. The branching unit is a component of
|
||
the IRFU which is situated between the IRFU transceiver
|
||
and IRFU antenna port. It provides the necessary
|
||
filtering, isolation and coupling."
|
||
::= { rfu 38 }
|
||
|
||
-- RadioLicense group attribute definitions
|
||
--
|
||
radioLicenseIdentifier OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Radio license identifier"
|
||
::= { radioLicense 1 }
|
||
|
||
radioLicenseBand OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
band-lower-6-ghz(0),
|
||
band-7-ghz(1),
|
||
band-8-ghz(2),
|
||
band-11-ghz(3),
|
||
band-13-ghz(4),
|
||
band-15-ghz(5),
|
||
band-18-ghz(6),
|
||
band-23-ghz(7),
|
||
band-26-ghz(8),
|
||
band-32-ghz(9),
|
||
band-38-ghz(10),
|
||
band-upper-6-ghz(11),
|
||
band-28-ghz(12),
|
||
band-42-ghz(13),
|
||
band-unsupported(14)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Radio license band"
|
||
::= { radioLicense 2 }
|
||
|
||
radioLicenseRegion OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
etsi(0),
|
||
fcc(1),
|
||
canada(2),
|
||
brazil(3),
|
||
ntia(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Radio license region"
|
||
::= { radioLicense 3 }
|
||
|
||
radioLicenseTxFreq OBJECT-TYPE
|
||
SYNTAX INTEGER (5925000..70000000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Radio license transmit frequency in kHz"
|
||
::= { radioLicense 4 }
|
||
|
||
radioLicenseRxFreq OBJECT-TYPE
|
||
SYNTAX INTEGER (5925000..70000000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Radio license receive frequency in kHz"
|
||
::= { radioLicense 5 }
|
||
|
||
radioLicenseBandwidth OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
bw-7-mhz(0),
|
||
bw-10-mhz(1),
|
||
bw-1375-mhz(2),
|
||
bw-14-mhz(3),
|
||
bw-20-mhz(4),
|
||
bw-275-mhz(5),
|
||
bw-28-mhz(6),
|
||
bw-30-mhz(7),
|
||
bw-40-mhz(8),
|
||
bw-50-mhz(9),
|
||
bw-55-mhz(10),
|
||
bw-56-mhz(11),
|
||
bw-80-mhz(12),
|
||
bw-25-mhz(13),
|
||
bw-60-mhz(14)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Radio license bandwidth"
|
||
::= { radioLicense 6 }
|
||
|
||
radioLicenseMaxEIRP OBJECT-TYPE
|
||
SYNTAX INTEGER (-300..1000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Maximum Effective Isotropic Radiated Power (EIRP)
|
||
permitted by the license. Expressed in 10ths of dBm"
|
||
::= { radioLicense 7 }
|
||
|
||
radioLicenseModulation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
mod-qpsk(0),
|
||
mod-8psk(1),
|
||
mod-16qam(2),
|
||
mod-32qam(3),
|
||
mod-64qam(4),
|
||
mod-128qam(5),
|
||
mod-256qam(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Radio license modulation"
|
||
::= { radioLicense 8 }
|
||
|
||
radioLicenseCodeRate OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Radio license code rate, multiplied by 100 to give two
|
||
decimal places of precision"
|
||
::= { radioLicense 9 }
|
||
|
||
radioLicenseIncompatibleAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
radio-license-incompatible-with-rfu(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Indicates if the radio license is incompatible with the
|
||
attached RFU. Re-run Installation to correct the issue"
|
||
::= { radioLicense 10 }
|
||
|
||
radioLicenseMinModulation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
mod-qpsk(0),
|
||
mod-8psk(1),
|
||
mod-16qam(2),
|
||
mod-32qam(3),
|
||
mod-64qam(4),
|
||
mod-128qam(5),
|
||
mod-256qam(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Certain licensing authorities, for example FCC and
|
||
Industry Canada, require adaptive modulation to be bound
|
||
by a minimum and maximum modulation mode as defined by
|
||
the radio license. This attribute is only of significance
|
||
in such regions and when adaptive modulation is enabled.
|
||
For other regions, for example ETSI, minimum and maximum
|
||
modulation mode are directly adjustable by the user and
|
||
are not defined by the radio license. In general, a
|
||
modulation mode is defined by two aspects, a modulation
|
||
and a code rate. This integer attribute identifies the
|
||
modulation aspect of the RadioLicenseMinModMode attribute
|
||
required by the radio license. For example, if
|
||
RadioLicenseMinModMode is configured for 16QAM 0.79, this
|
||
attribute will be set to a value of 2 which identifies a
|
||
modulation of 16QAM."
|
||
::= { radioLicense 11 }
|
||
|
||
radioLicenseMinCodeRate OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Certain licensing authorities, for example FCC and
|
||
Industry Canada, require adaptive modulation to be bound
|
||
by a minimum and maximum modulation mode as defined by
|
||
the radio license. This attribute is only of significance
|
||
in such regions and when adaptive modulation is enabled.
|
||
For other regions, for example ETSI, minimum and maximum
|
||
modulation mode are directly adjustable by the user and
|
||
are not defined by the radio license. In general, a
|
||
modulation mode is defined by two aspects, a modulation
|
||
and a code rate. This attribute is equal to 100 times the
|
||
code rate aspect of the RadioLicenseMinModMode attribute
|
||
required by the radio license. For example, if
|
||
RadioLicenseMinModMode is configured for QPSK 0.80, this
|
||
attribute will read 80."
|
||
::= { radioLicense 12 }
|
||
|
||
radioLicenseMaxModulation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
mod-qpsk(0),
|
||
mod-8psk(1),
|
||
mod-16qam(2),
|
||
mod-32qam(3),
|
||
mod-64qam(4),
|
||
mod-128qam(5),
|
||
mod-256qam(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Certain licensing authorities, for example FCC and
|
||
Industry Canada, require adaptive modulation to be bound
|
||
by a minimum and maximum modulation mode as defined by
|
||
the radio license. This attribute is only of significance
|
||
in such regions and when adaptive modulation is enabled.
|
||
For other regions, for example ETSI, minimum and maximum
|
||
modulation mode are directly adjustable by the user and
|
||
are not defined by the radio license. In general, a
|
||
modulation mode is defined by two aspects, a modulation
|
||
and a code rate. This integer attribute identifies the
|
||
modulation aspect of the RadioLicenseMaxModMode attribute
|
||
required by the radio license. For example, if
|
||
RadioLicenseMaxModMode is configured for 256QAM 0.91,
|
||
this attribute will be set to a value of 6 which
|
||
identifies a modulation of 256QAM."
|
||
::= { radioLicense 13 }
|
||
|
||
radioLicenseMaxCodeRate OBJECT-TYPE
|
||
SYNTAX INTEGER (0..100)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Certain licensing authorities, for example FCC and
|
||
Industry Canada, require adaptive modulation to be bound
|
||
by a minimum and maximum modulation mode as defined by
|
||
the radio license. This attribute is only of significance
|
||
in such regions and when adaptive modulation is enabled.
|
||
For other regions, for example ETSI, minimum and maximum
|
||
modulation mode are directly adjustable by the user and
|
||
are not defined by the radio license. In general, a
|
||
modulation mode is defined by two aspects, a modulation
|
||
and a code rate. This attribute is equal to 100 times the
|
||
code rate aspect of the RadioLicenseMaxModMode attribute
|
||
required by the radio license. For example, if
|
||
RadioLicenseMaxModMode is configured for 256QAM 0.91,
|
||
this attribute will read 91."
|
||
::= { radioLicense 14 }
|
||
|
||
-- ProtectionConfig group attribute definitions
|
||
--
|
||
protection OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
hot-standby-1plus1(1),
|
||
hot-standby-1plus1-with-rx-diversity(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"PTP 800 supports a 1+1 Hot Standby configuration where
|
||
the wireless link is protected against hardware failure.
|
||
This requires the installation of redundant equipment at
|
||
each end of the wireless link including a secondary CMU
|
||
and RFU. At a given end of the wireless link, only one
|
||
CMU / RFU is Active at any one time, the neighbor CMU /
|
||
RFU being Inactive. When a fault is detected on the
|
||
Active CMU / RFU, the Active role will automatically
|
||
switch to the Inactive CMU / RFU. To enable functionality
|
||
associated with this feature, this attribute must be
|
||
configured for a setting of 1+1."
|
||
::= { protectionConfig 1 }
|
||
|
||
faultProtectionSwitching OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, protection switching
|
||
on detection of a fault can be enabled/disabled using
|
||
this attribute."
|
||
::= { protectionConfig 2 }
|
||
|
||
primarySecondaryMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
primary(0),
|
||
secondary(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"At a given end of a 1+1 Hot Standby configuration, one
|
||
CMU must be configured as Primary, the other CMU as
|
||
Secondary. When a Protected Link initialises with no
|
||
faults, the CMUs configured as Primary will become the
|
||
Active CMUs, that is, the Primary CMUs are the preferred
|
||
CMUs. When RFUs are connected to the antenna via an
|
||
Asymmetric Coupler, the RFU which is connected to the
|
||
Primary CMU should be connected to the Main path of the
|
||
coupler. This is the path with the lowest loss."
|
||
::= { protectionConfig 3 }
|
||
|
||
numberOfAntennas OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
one(0),
|
||
two(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This must be configured to match the number of antennas
|
||
installed at this end of the link."
|
||
::= { protectionConfig 4 }
|
||
|
||
primaryRecovery OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"At a given end of a 1+1 Hot Standby configuration, the
|
||
CMU configured as Primary is the preferred unit to take
|
||
the Active role. If the Primary Recovery attribute is set
|
||
to Enabled at a given end, a protection switch back to
|
||
the preferred Primary CMU / RFU will occur autonomously
|
||
if it has stayed free of faults for a configurable period
|
||
of time determined by the Primary Recovery Period."
|
||
::= { protectionConfig 5 }
|
||
|
||
primaryRecoveryPeriod OBJECT-TYPE
|
||
SYNTAX INTEGER (0..2880)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"At a given end of a 1+1 Hot Standby configuration, the
|
||
CMU configured as Primary is the preferred unit to take
|
||
the Active role. If the Primary Recovery attribute is set
|
||
to Enabled at a given end, a protection switch back to
|
||
the preferred Primary CMU / RFU will occur autonomously
|
||
if it has stayed free of faults for a configurable period
|
||
of time determined by the Primary Recovery Period."
|
||
::= { protectionConfig 6 }
|
||
|
||
requestedProtectionState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
inactive(0),
|
||
active(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, only one CMU / RFU
|
||
at a given end of the link is Active at any one time, the
|
||
neighbor CMU / RFU being Inactive. Use the Requested
|
||
Protection State attribute to request whether this CMU /
|
||
RFU should be in the Active or Inactive state."
|
||
::= { protectionConfig 7 }
|
||
|
||
antennaReceiveLevelDeltaThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..30)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"At a given end of a 1+1 Hot Standby configuration, a CMU
|
||
will raise an alarm to the management system when the
|
||
measured receive level adjusted by antenna gain and
|
||
feeder loss is less than that of its neighbor by more
|
||
than the Antenna Receive Level Delta Threshold."
|
||
::= { protectionConfig 8 }
|
||
|
||
antennaReceiveLevelMeasurementWindow OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2880)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"At a given end of a 1+1 Hot Standby configuration, a CMU
|
||
will raise an alarm to the management system when the
|
||
measured receive level adjusted by antenna gain and
|
||
feeder loss is less than that of its neighbor by more
|
||
than the Antenna Receive Level Delta Threshold. The
|
||
measurements are averaged over the most recent Antenna
|
||
Receive Level Measurement Window."
|
||
::= { protectionConfig 9 }
|
||
|
||
fiberY OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"One or both ends of a 1+1 Hot Standby system can be
|
||
connected to the network using an 'Optical-Y Splitter Kit
|
||
per end'. This end configuration provides a single fiber
|
||
interface to the network. Any end which is connected to
|
||
the network using this method must have the Fiber Y
|
||
attribute set to Enabled. Please note: CMUs must be
|
||
loaded with boot code version 03-00 or later and recovery
|
||
version 04-00 or later for Fiber Y to work correctly."
|
||
::= { protectionConfig 12 }
|
||
|
||
rxDiversityVlanTpid OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ieee-8021q-tagged-c-tag-type-8100(0),
|
||
ieee-8021ad-tagged-s-tag-or-b-tag-type-88a8(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When Receive Diversity is enabled, the Inactive CMU
|
||
sends Rx Diversity Ethernet Frames to the Active CMU.
|
||
These Ethernet Frames must be VLAN tagged and this
|
||
attribute controls whether the frames are tagged using
|
||
the TPID defined by 802.1Q or the TPID defined by
|
||
802.1ad."
|
||
::= { protectionConfig 14 }
|
||
|
||
rxDiversityVid OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4094)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When Receive Diversity is enabled, the Inactive CMU
|
||
sends Rx Diversity Ethernet Frames to the Active CMU.
|
||
These Ethernet Frames must be VLAN tagged and this
|
||
attribute controls the VLAN Identifier"
|
||
::= { protectionConfig 15 }
|
||
|
||
-- ProtectionStatus group attribute definitions
|
||
--
|
||
protectionAvailabilityStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
not-protected(1),
|
||
not-protecting(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Protection
|
||
Availability Status attribute indicates whether the
|
||
Active unit is currently being protected by the Inactive
|
||
unit. If it isn't being protected, the Active unit will
|
||
report Not Protected and the Inactive unit will report
|
||
Not Protecting."
|
||
::= { protectionStatus 2 }
|
||
|
||
protectionConfigurationStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
configuration-not-protecting(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, this attribute will
|
||
indicate whether the configuration will support
|
||
protection."
|
||
::= { protectionStatus 3 }
|
||
|
||
protectionState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
inactive(0),
|
||
active(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, only one CMU / RFU
|
||
at a given end of the link is Active at any one time, the
|
||
neighbor CMU / RFU being Inactive. The Protection State
|
||
attribute indicates whether a CMU / RFU is in the Active
|
||
or Inactive state."
|
||
::= { protectionStatus 4 }
|
||
|
||
activeUnit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
primary(0),
|
||
secondary(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"At a given end of a 1+1 Hot Standby configuration, one
|
||
CMU must be configured as Primary, the other CMU as
|
||
Secondary. When a Protected Link initialises with no
|
||
faults, the CMU configured as Primary will become the
|
||
Active CMU, that is, the Primary CMU is the preferred
|
||
CMUs. The Active Unit attribute indicates whether the
|
||
active unit is configured as Primary or Secondary."
|
||
::= { protectionStatus 5 }
|
||
|
||
protectionSwitchCause OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no-previous-protection-switch(0),
|
||
neighbor-cmu-connected-but-not-responding(1),
|
||
rfu-not-responding(2),
|
||
rfu-rx-rf-synth-out-of-lock(3),
|
||
rfu-tx-rf-synth-out-of-lock(4),
|
||
rfu-common-rf-synth-out-of-lock(5),
|
||
rfu-cable-failure(6),
|
||
rfu-cable-attenuator-adjustment-failure(7),
|
||
rfu-tx-power-degraded(8),
|
||
data-port-down(9),
|
||
management-port-down(10),
|
||
wireless-receive-signal-not-detected(11),
|
||
byte-error-ratio-over-threshold(12),
|
||
code-word-error-ratio-over-threshold(13),
|
||
cmu-rebooting(14),
|
||
configuration-not-protecting(15),
|
||
wireless-receive-signal-not-detected-at-remote-end(16),
|
||
byte-error-ratio-over-threshold-at-remote-end(17),
|
||
code-word-error-ratio-over-threshold-at-remote-end(18),
|
||
multiple-receive-failure-at-remote-end(19),
|
||
primary-recovery(20),
|
||
managed-protection-switch(21),
|
||
rfu-rx-if-synth-out-of-lock(22),
|
||
rfu-tx-if-synth-out-of-lock(23),
|
||
rfu-common-if-synth-out-of-lock(24),
|
||
rfu-very-high-temperature(25)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Protection
|
||
Switch Cause attribute reports the reason for the last
|
||
protection switch."
|
||
::= { protectionStatus 6 }
|
||
|
||
endId OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..79))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the End Id contains
|
||
the IP address of neighboring CMUs starting with the
|
||
highest IP address and with a space separating the
|
||
addresses. It is a single identifier of neighboring
|
||
CMUs."
|
||
::= { protectionStatus 7 }
|
||
|
||
neighborIPAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Neighbor IP
|
||
Address identifies the IP Address of the neighbor CMU
|
||
connected via the Protection Interface."
|
||
::= { protectionStatus 8 }
|
||
|
||
neighborMACAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(6))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Neighbor MAC
|
||
Address identifies the MAC Address of the neighbor CMU
|
||
connected via the Protection Interface."
|
||
::= { protectionStatus 9 }
|
||
|
||
wirelessReceiveSignalStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
not-detected(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The Wireless Receive Signal Status indicates if the
|
||
receiver is able to demodulate the transmit signal from
|
||
the remote end of the link. If it cannot demodulate the
|
||
signal, a protection switch may occur in a system
|
||
configured for 1+1 Hot Standby."
|
||
::= { protectionStatus 10 }
|
||
|
||
licensedTransmitCapacityStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
less-than-neighbor(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Licensed
|
||
Transmit Capacity Status attribute indicates when the
|
||
Licensed Transmit Capacity is below that of its
|
||
neighbor."
|
||
::= { protectionStatus 14 }
|
||
|
||
dataPortEthernetSpeedStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
less-than-neighbor(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Data Port
|
||
Ethernet Speed Status attribute indicates if the Ethernet
|
||
Speed of the Data Port is below that of its neighbor."
|
||
::= { protectionStatus 15 }
|
||
|
||
managementPortEthernetSpeedStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
less-than-neighbor(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Management Port
|
||
Ethernet Speed Status attribute indicates if the Ethernet
|
||
Speed of the Management Port is below that of its
|
||
neighbor."
|
||
::= { protectionStatus 16 }
|
||
|
||
protectionInterfaceStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
neighbor-not-responding(1),
|
||
neighbor-not-connected(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, information is
|
||
shared between neighbor CMUs over the Protection
|
||
Interface. The Protection Interface Status attribute
|
||
reports whether the neighbor CMU is successfully
|
||
responding, physically disconnected or whether it is
|
||
physically connected but not responding, e.g. powered
|
||
down."
|
||
::= { protectionStatus 17 }
|
||
|
||
remotePrimaryIPAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Remote Primary
|
||
IP Address reports the IP address of the CMU which is
|
||
configured as Primary at the remote end of the wireless
|
||
link."
|
||
::= { protectionStatus 18 }
|
||
|
||
remoteSecondaryIPAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Remote Secondary
|
||
IP Address reports the IP address of the CMU which is
|
||
configured as Secondary at the remote end of the wireless
|
||
link."
|
||
::= { protectionStatus 19 }
|
||
|
||
remotePrimaryMACAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(6))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Remote Primary
|
||
MAC Address reports the MAC address of the CMU which is
|
||
configured as Primary at the remote end of the wireless
|
||
link."
|
||
::= { protectionStatus 20 }
|
||
|
||
remoteSecondaryMACAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(6))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Remote Secondary
|
||
MAC Address reports the MAC address of the CMU which is
|
||
configured as Secondary at the remote end of the wireless
|
||
link."
|
||
::= { protectionStatus 21 }
|
||
|
||
remotePrimarySecondaryMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
primary(0),
|
||
secondary(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, this attribute
|
||
identifies whether the Active Unit at the remote end of
|
||
the link is configured as Primary or Secondary."
|
||
::= { protectionStatus 22 }
|
||
|
||
transmitterStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
muted(0),
|
||
transmitting(1),
|
||
inactive(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Indicates whether the RFU is transmitting or muted. In a
|
||
1+1 Hot Standby configuration, it will also indicate if
|
||
the RFU is Inactive and therefore ready to transmit."
|
||
::= { protectionStatus 23 }
|
||
|
||
endWirelessReceiveSignalStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
not-detected(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The End Wireless Receive Signal Status indicates if the
|
||
end of a link is unable to demodulate the signal
|
||
transmitted from the remote end of the link. When
|
||
Protection is set to 1+1 Hot Standby, this attribute will
|
||
indicate Not Detected if the Active CMU is unable to
|
||
demodulate the wireless signal. When Receive Diversity is
|
||
enabled, this attribute will indicate Not Detected if
|
||
both the Active and Inactive CMUs are unable to
|
||
demodulate the wireless signal."
|
||
::= { protectionStatus 26 }
|
||
|
||
rxDiversityDataPortStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
not-protecting(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"When Receive Diversity is enabled, the Inactive CMU
|
||
sends Rx Diversity Ethernet Frames to the Active CMU.
|
||
Before sending these frames, the Data Port MUST be
|
||
negotiated at 1000 Mbps. This attribute indicates if this
|
||
is not the case"
|
||
::= { protectionStatus 27 }
|
||
|
||
rxDiversityAvailabilityStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
not-protected(1),
|
||
not-protecting(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The Rx Diversity Availability Status attribute will
|
||
indicate when Receive Diversity is not operating
|
||
correctly, either due to a fault or due to an incorrect
|
||
configuration"
|
||
::= { protectionStatus 28 }
|
||
|
||
rxDiversityConfigurationStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
configuration-not-protecting(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"For Receive Diversity to operate correctly, certain
|
||
attributes must be configured correctly on both neighbor
|
||
CMUs. The Rx Diversity Configuration Status attribute
|
||
will indicate when this is not the case"
|
||
::= { protectionStatus 29 }
|
||
|
||
rxDiversityNeighborCompatibility OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
mismatch(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"For Receive Diversity to operate correctly, both
|
||
neighbor CMUs must both be configured with the Protection
|
||
attribute set to <20>1+1 Hot Standby with Rx Diversity<74>.
|
||
The Rx Diversity Neighbor Compatibility attribute
|
||
indicates when the neighbor CMU is configured to a
|
||
different setting"
|
||
::= { protectionStatus 30 }
|
||
|
||
rxDiversityVlanTpidNeighborCompatibility OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
mismatch(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"For Receive Diversity to operate correctly, both
|
||
neighbor CMUs must be configured with the same value of
|
||
Rx Diversity VLAN TPID. The Rx Diversity VLAN TPID
|
||
Neighbor Compatibility attribute indicates when this is
|
||
not the case"
|
||
::= { protectionStatus 31 }
|
||
|
||
rxDiversityVidNeighborCompatibility OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ok(0),
|
||
mismatch(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"For Receive Diversity to operate correctly, both
|
||
neighbor CMUs must be configured with the same value of
|
||
Rx Diversity VID. The Rx Diversity VID Neighbor
|
||
Compatibility attribute indicates when this is not the
|
||
case"
|
||
::= { protectionStatus 32 }
|
||
|
||
neighborInternetAddressType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(0),
|
||
ipv4(1),
|
||
ipv6(2),
|
||
ipv4z(3),
|
||
ipv6z(4),
|
||
unknown-6(5),
|
||
unknown-7(6),
|
||
unknown-8(7),
|
||
unknown-9(8),
|
||
unknown-10(9),
|
||
unknown-11(10),
|
||
unknown-12(11),
|
||
unknown-13(12),
|
||
unknown-14(13),
|
||
unknown-15(14),
|
||
unknown-16(15),
|
||
dns(16)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of Internet address specified by the associated
|
||
neighborInternetAddress."
|
||
::= { protectionStatus 33 }
|
||
|
||
neighborInternetAddress OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Neighbor
|
||
Internet Address identifies the INET Address of the
|
||
neighbor CMU connected via the Protection Interface."
|
||
::= { protectionStatus 34 }
|
||
|
||
remotePrimaryInternetAddressType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(0),
|
||
ipv4(1),
|
||
ipv6(2),
|
||
ipv4z(3),
|
||
ipv6z(4),
|
||
unknown-6(5),
|
||
unknown-7(6),
|
||
unknown-8(7),
|
||
unknown-9(8),
|
||
unknown-10(9),
|
||
unknown-11(10),
|
||
unknown-12(11),
|
||
unknown-13(12),
|
||
unknown-14(13),
|
||
unknown-15(14),
|
||
unknown-16(15),
|
||
dns(16)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of Internet address specified by the associated
|
||
remoteSecondaryInternetAddress."
|
||
::= { protectionStatus 35 }
|
||
|
||
remotePrimaryInternetAddress OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Remote Primary
|
||
Internet Address reports the INET address of the CMU
|
||
which is configured as Primary at the remote end of the
|
||
wireless link."
|
||
::= { protectionStatus 36 }
|
||
|
||
remoteSecondaryInternetAddressType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(0),
|
||
ipv4(1),
|
||
ipv6(2),
|
||
ipv4z(3),
|
||
ipv6z(4),
|
||
unknown-6(5),
|
||
unknown-7(6),
|
||
unknown-8(7),
|
||
unknown-9(8),
|
||
unknown-10(9),
|
||
unknown-11(10),
|
||
unknown-12(11),
|
||
unknown-13(12),
|
||
unknown-14(13),
|
||
unknown-15(14),
|
||
unknown-16(15),
|
||
dns(16)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of Internet address specified by the associated
|
||
remoteSecondaryInternetAddress."
|
||
::= { protectionStatus 37 }
|
||
|
||
remoteSecondaryInternetAddress OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Remote Secondary
|
||
Internet Address reports the INET address of the CMU
|
||
which is configured as Secondary at the remote end of the
|
||
wireless link."
|
||
::= { protectionStatus 38 }
|
||
|
||
-- ProtectionStats group attribute definitions
|
||
--
|
||
activeAvailableTime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The Active Available Time reports the time which the
|
||
Wireless Link Status has been Up whilst the CMU/RFU has
|
||
been in the Active role of a 1+1 Hot Standby
|
||
configuration. The reported time is since the last
|
||
statistics reset."
|
||
::= { protectionStats 5 }
|
||
|
||
activeCounterMeasurementPeriod OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"For a 1+1 Hot Standby link, the elapsed time that the
|
||
Protection State of the unit has been in the active state
|
||
since the last reset of the system counters."
|
||
::= { protectionStats 6 }
|
||
|
||
activeWirelessLinkAvailability OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1000000)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"For a 1+1 Hot Standby link, the percentage of time that
|
||
the unit has been able to successfully demodulate the
|
||
signal transmitted from the remote end of the link whilst
|
||
the Protecion State of the unit has been active. This
|
||
attribute is not updated whilst the Protection State is
|
||
inactive. Calculated since the last reset of the system
|
||
counters. The reported value is the percentage multiplied
|
||
by 10000"
|
||
::= { protectionStats 7 }
|
||
|
||
-- AAAControl group attribute definitions
|
||
--
|
||
userTableNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Number of entries in the userTable"
|
||
::= { aAAControl 1 }
|
||
|
||
-- UserTable group attribute definitions
|
||
--
|
||
userTableIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..10)
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"used to index values in the userTable."
|
||
::= { userTableEntry 1 }
|
||
|
||
userName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"User name which must be entered, along with the
|
||
appropriate password, in order to gain access to the
|
||
system."
|
||
::= { userTableEntry 2 }
|
||
|
||
userRole OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
read-only(0),
|
||
system-administrator(1),
|
||
security-officer(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Role of the selected user. A Security Officer has access
|
||
to and can modify all settings. A System Administrator
|
||
has access to and can modify all non-security settings. A
|
||
Read Only user can view settings, but cannot make any
|
||
changes."
|
||
::= { userTableEntry 3 }
|
||
|
||
userEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Enable / Disable the selected user"
|
||
::= { userTableEntry 4 }
|
||
|
||
userPassword OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"User password, which must be entered in order to gain
|
||
access to the system."
|
||
::= { userTableEntry 5 }
|
||
|
||
-- SyslogControl group attribute definitions
|
||
--
|
||
syslogClient OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Enable or disable the syslog client"
|
||
::= { syslogControl 1 }
|
||
|
||
syslogState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The syslog service has been enabled or disabled"
|
||
::= { syslogControl 2 }
|
||
|
||
-- Supplementary group attribute definitions
|
||
--
|
||
longitude OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..19))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The longitude of the unit, measured in decimal degrees.
|
||
This object is set by the SNMP manager and has no
|
||
internal function."
|
||
::= { supplementary 1 }
|
||
|
||
latitude OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE(0..19))
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The latitude of the unit, measured in decimal degrees.
|
||
This object is set by the SNMP manager and has no
|
||
internal function."
|
||
::= { supplementary 2 }
|
||
|
||
altitude OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The altitude of the unit, measured in metres. This
|
||
object is set by the SNMP manager and has no internal
|
||
function."
|
||
::= { supplementary 3 }
|
||
|
||
-- Enterprise TRAP definitions
|
||
--
|
||
|
||
dataPortStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { dataPortStatus }
|
||
DESCRIPTION
|
||
"Current status of the data Ethernet link. NB: a change
|
||
of state may generate an SNMP trap and/or SMTP email
|
||
alert"
|
||
::= 3
|
||
|
||
linkNameMismatchTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { linkNameMismatch }
|
||
DESCRIPTION
|
||
"Signaling was received with the wrong Link Name. Either
|
||
the Link Name is configured differently at each end of
|
||
the wireless link, or this unit is aligned to the wrong
|
||
link partner. NB: A change of value during operation may
|
||
generate an SNMP trap and/or SMTP email alert"
|
||
::= 9
|
||
|
||
alignmentModeTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { alignmentMode }
|
||
DESCRIPTION
|
||
"Indicates if the unit is undergoing alignment. NB: a
|
||
change of state during operation may generate an SNMP
|
||
trap and/or SMTP email alert"
|
||
::= 10
|
||
|
||
unitOutOfCalibrationTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { unitOutOfCalibration }
|
||
DESCRIPTION
|
||
"The unit is out of calibration"
|
||
::= 11
|
||
|
||
encryptionEnabledMismatchTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { encryptionEnabledMismatch }
|
||
DESCRIPTION
|
||
"Encryption has been enabled on one end of the wireless
|
||
link but not the other"
|
||
::= 13
|
||
|
||
dataPortDisabledWarningTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { dataPortDisabledWarning }
|
||
DESCRIPTION
|
||
"The SNMP ifAdminStatus of the data Ethernet interface
|
||
has disabled Ethernet traffic"
|
||
::= 17
|
||
|
||
dataPortFiberStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { dataPortFiberStatus }
|
||
DESCRIPTION
|
||
"If the fiber interface on the data Ethernet port is not
|
||
OK, there are three possible causes: 1) the fiber
|
||
interface has been installed but disabled, 2) the
|
||
interface could not be established even though no LOS was
|
||
detected (i.e. an optical carrier was detected, which
|
||
could be due to a broken TX fiber, or because the
|
||
interface is disabled at the other end of the fiber
|
||
link), or 3) the interface could not be established and
|
||
LOS is detected (i.e. no optical carrier is detected).
|
||
NB: a change of status may generate an SNMP trap and/or
|
||
SMTP email alert"
|
||
::= 18
|
||
|
||
dataPortConfigurationMismatchTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { dataPortConfigurationMismatch }
|
||
DESCRIPTION
|
||
"The detection of Ethernet fragments (runt packets) on
|
||
the data Ethernet port when the link is in full duplex is
|
||
an indication of an auto-negotiation or forced
|
||
configuration mismatch"
|
||
::= 19
|
||
|
||
softwareVersionRemoteCompatibilityTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { softwareVersionRemoteCompatibility }
|
||
DESCRIPTION
|
||
"Indicates a mismatch of software versions at the two
|
||
ends of the wireless link"
|
||
::= 20
|
||
|
||
sNTPSyncTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { sNTPSync }
|
||
DESCRIPTION
|
||
"If SNTP Sync fails then check the server settings in the
|
||
Remote Management page, or disable SNTP. NB: a change of
|
||
state may generate an SNMP trap and/or SMTP email alert"
|
||
::= 21
|
||
|
||
managementPortStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { managementPortStatus }
|
||
DESCRIPTION
|
||
"Current status of the out-of-band management Ethernet
|
||
link"
|
||
::= 23
|
||
|
||
managementPortDisabledWarningTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { managementPortDisabledWarning }
|
||
DESCRIPTION
|
||
"The SNMP ifAdminStatus of the out-of-band management
|
||
Ethernet interface has disabled Ethernet traffic"
|
||
::= 24
|
||
|
||
rFUStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { rFUStatus }
|
||
DESCRIPTION
|
||
"Current status of the RFU. A state of 'ok' indicates
|
||
that the RFU is fully operational, although may not be
|
||
transmitting."
|
||
::= 27
|
||
|
||
managementPortConfigurationMismatchTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { managementPortConfigurationMismatch }
|
||
DESCRIPTION
|
||
"The detection of Ethernet fragments (runt packets) on
|
||
the out-of-band management Ethernet port when the link is
|
||
in full duplex is an indication of an auto-negotiation or
|
||
forced configuration mismatch"
|
||
::= 28
|
||
|
||
wirelessLinkStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { wirelessLinkStatus }
|
||
DESCRIPTION
|
||
"Current status of the wireless link"
|
||
::= 29
|
||
|
||
protectionAvailabilityStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { protectionAvailabilityStatus }
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Protection
|
||
Availability Status attribute indicates whether the
|
||
Active unit is currently being protected by the Inactive
|
||
unit. If it isn't being protected, the Active unit will
|
||
report Not Protected and the Inactive unit will report
|
||
Not Protecting."
|
||
::= 31
|
||
|
||
protectionConfigurationStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { protectionConfigurationStatus }
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, this attribute will
|
||
indicate whether the configuration will support
|
||
protection."
|
||
::= 32
|
||
|
||
protectionStateTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { protectionState }
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, only one CMU / RFU
|
||
at a given end of the link is Active at any one time, the
|
||
neighbor CMU / RFU being Inactive. The Protection State
|
||
attribute indicates whether a CMU / RFU is in the Active
|
||
or Inactive state."
|
||
::= 33
|
||
|
||
wirelessReceiveSignalStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { wirelessReceiveSignalStatus }
|
||
DESCRIPTION
|
||
"The Wireless Receive Signal Status indicates if the
|
||
receiver is able to demodulate the transmit signal from
|
||
the remote end of the link. If it cannot demodulate the
|
||
signal, a protection switch may occur in a system
|
||
configured for 1+1 Hot Standby."
|
||
::= 34
|
||
|
||
licensedTransmitCapacityStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { licensedTransmitCapacityStatus }
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Licensed
|
||
Transmit Capacity Status attribute indicates when the
|
||
Licensed Transmit Capacity is below that of its
|
||
neighbor."
|
||
::= 36
|
||
|
||
dataPortEthernetSpeedStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { dataPortEthernetSpeedStatus }
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Data Port
|
||
Ethernet Speed Status attribute indicates if the Ethernet
|
||
Speed of the Data Port is below that of its neighbor."
|
||
::= 37
|
||
|
||
managementPortEthernetSpeedStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { managementPortEthernetSpeedStatus }
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, the Management Port
|
||
Ethernet Speed Status attribute indicates if the Ethernet
|
||
Speed of the Management Port is below that of its
|
||
neighbor."
|
||
::= 38
|
||
|
||
protectionInterfaceStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { protectionInterfaceStatus }
|
||
DESCRIPTION
|
||
"In a 1+1 Hot Standby configuration, information is
|
||
shared between neighbor CMUs over the Protection
|
||
Interface. The Protection Interface Status attribute
|
||
reports whether the neighbor CMU is successfully
|
||
responding, physically disconnected or whether it is
|
||
physically connected but not responding, e.g. powered
|
||
down."
|
||
::= 39
|
||
|
||
syslogStateTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { syslogState }
|
||
DESCRIPTION
|
||
"The syslog service has been enabled or disabled"
|
||
::= 40
|
||
|
||
syslogLocalNearlyFullTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
DESCRIPTION "The syslog local log is nearly full (90%)"
|
||
::= 41
|
||
|
||
syslogLocalWrappedTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
DESCRIPTION "The syslog local log has wrapped"
|
||
::= 42
|
||
|
||
secureModeAlarmTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { secureModeAlarm }
|
||
DESCRIPTION
|
||
"The secure mode (e.g. FIPS, UC-APL) state of the unit.
|
||
The secure mode is not configured(1) state indicates that
|
||
the unit is capable of secure mode operation, and one or
|
||
more of the following security materials has not been
|
||
configured: Key Of Keys, Private Key, Public Certificate,
|
||
DRNG Entropy Status, Wireless Encryption Key. The secure
|
||
mode mode is configured but not active(2) state indicates
|
||
that the unit is capable of secure mode operation, and
|
||
the security material has been configured, but the
|
||
configuration of interfaces is not consistent with secure
|
||
mode operation. The secure mode is not supported(3) state
|
||
indicates that the unit is not capable of secure mode
|
||
operation. The secure mode capability requires
|
||
appropriate hardware compatibility, license key and
|
||
software image."
|
||
::= 43
|
||
|
||
endWirelessReceiveSignalStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { endWirelessReceiveSignalStatus }
|
||
DESCRIPTION
|
||
"The End Wireless Receive Signal Status indicates if the
|
||
end of a link is unable to demodulate the signal
|
||
transmitted from the remote end of the link. When
|
||
Protection is set to 1+1 Hot Standby, this attribute will
|
||
indicate Not Detected if the Active CMU is unable to
|
||
demodulate the wireless signal. When Receive Diversity is
|
||
enabled, this attribute will indicate Not Detected if
|
||
both the Active and Inactive CMUs are unable to
|
||
demodulate the wireless signal."
|
||
::= 44
|
||
|
||
rxDiversityDataPortStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { rxDiversityDataPortStatus }
|
||
DESCRIPTION
|
||
"When Receive Diversity is enabled, the Inactive CMU
|
||
sends Rx Diversity Ethernet Frames to the Active CMU.
|
||
Before sending these frames, the Data Port MUST be
|
||
negotiated at 1000 Mbps. This attribute indicates if this
|
||
is not the case"
|
||
::= 45
|
||
|
||
rxDiversityAvailabilityStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { rxDiversityAvailabilityStatus }
|
||
DESCRIPTION
|
||
"The Rx Diversity Availability Status attribute will
|
||
indicate when Receive Diversity is not operating
|
||
correctly, either due to a fault or due to an incorrect
|
||
configuration"
|
||
::= 46
|
||
|
||
rxDiversityConfigurationStatusTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { rxDiversityConfigurationStatus }
|
||
DESCRIPTION
|
||
"For Receive Diversity to operate correctly, certain
|
||
attributes must be configured correctly on both neighbor
|
||
CMUs. The Rx Diversity Configuration Status attribute
|
||
will indicate when this is not the case"
|
||
::= 47
|
||
|
||
rFUPowerButtonPressedTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { rFUPowerButtonPressed }
|
||
DESCRIPTION
|
||
"IRFU power button have been pressed, IFRU has powered
|
||
down unexpectedly"
|
||
::= 48
|
||
|
||
syslogClientTrap TRAP-TYPE
|
||
ENTERPRISE ptpTraps
|
||
VARIABLES { syslogClient }
|
||
DESCRIPTION
|
||
"Enable or disable the syslog client"
|
||
::= 49
|
||
|
||
END
|