2897 lines
146 KiB
Plaintext
2897 lines
146 KiB
Plaintext
-- File Name : SPC200.txt
|
||
|
||
-- Date : Wed Aug 23 14:03:00 CEST 2006
|
||
-- Author : Gilles Marceau
|
||
|
||
-- Date : Tue Jul 06 18:48:54 CEST 2004
|
||
-- Author : Luc Capanaccia
|
||
|
||
-- Date : Tue Jul 22 12:00:00 CEST 2004
|
||
-- Reviewed by : Gilles Dupont
|
||
|
||
-- Date : Mon Sep 13 12:00:00 CEST 2004
|
||
-- Reviewed by : Gilles Dupont
|
||
|
||
-- Date : Mon Sep 21 12:00:00 CEST 2004
|
||
-- Reviewed by : Gilles Dupont
|
||
|
||
-- Date : Tue Nov 16 12:30:00 CEST 2004
|
||
-- Reviewed by : Luc Capanaccia
|
||
|
||
-- Date : Fri Dec 17 12:30:00 CEST 2004
|
||
-- Reviewed by : Luc Capanaccia
|
||
|
||
-- Date : Thu Sep 15 14:00:00 CEST 2005
|
||
-- Reviewed by : Philippe Rimauro (Tag PR01)
|
||
|
||
-- Date : Thu Feb 08 14:03:00 CEST 2007
|
||
-- Author : Gilles Marceau
|
||
|
||
SPC200 DEFINITIONS ::= BEGIN
|
||
IMPORTS
|
||
RowStatus, TruthValue, MacAddress, DisplayString, TEXTUAL-CONVENTION
|
||
FROM SNMPv2-TC
|
||
AGENT-CAPABILITIES, OBJECT-GROUP, MODULE-COMPLIANCE
|
||
FROM SNMPv2-CONF
|
||
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32,
|
||
Counter32, IpAddress, Unsigned32, Gauge32
|
||
FROM SNMPv2-SMI
|
||
interfaces, ifIndex
|
||
FROM IF-MIB
|
||
spidcom
|
||
FROM SPIDCOM-MIB;
|
||
|
||
spc200MIB MODULE-IDENTITY
|
||
|
||
LAST-UPDATED "200412171230Z" -- December 17, 2004
|
||
|
||
ORGANIZATION "Organization"
|
||
CONTACT-INFO "Contact-info"
|
||
DESCRIPTION "Description"
|
||
|
||
REVISION "200412171230Z"
|
||
DESCRIPTION "Add software upgrade features"
|
||
|
||
REVISION "200411161230Z"
|
||
DESCRIPTION "Add adapt level table , commit and reset command"
|
||
|
||
REVISION "200409211200Z"
|
||
DESCRIPTION "Add quick access to channel modulation and pilots"
|
||
|
||
REVISION "200409131200Z"
|
||
DESCRIPTION "Add quick access to notches"
|
||
|
||
REVISION "200407221200Z"
|
||
DESCRIPTION "Corrected compilation errors"
|
||
|
||
REVISION "200407011757Z"
|
||
DESCRIPTION "Initial revision"
|
||
|
||
::= { spidcom 1 }
|
||
|
||
-- TEXTUAL-CONVENTIONS --
|
||
ModulationValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Modulation amplitude used by a group of carriers."
|
||
SYNTAX INTEGER { none ( 1 ) ,
|
||
bpsk ( 2 ) ,
|
||
qpsk ( 3 ) ,
|
||
qam16 ( 4 ) ,
|
||
qam64 ( 5 ) ,
|
||
qam256 ( 6 ) }
|
||
|
||
CarrierValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A group is composed of 8 carriers."
|
||
SYNTAX Integer32 ( 1 .. 8 )
|
||
|
||
PilotValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The pilot carrier wave can be chosen between
|
||
the carrier 1 up to carrier 128 inside a band carrier range."
|
||
SYNTAX Integer32 ( 1 .. 128 )
|
||
|
||
BandValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A channel is composed of 7 bands."
|
||
SYNTAX Integer32 ( 1 .. 7 )
|
||
|
||
PlcChannelType ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The different type of plc channels:
|
||
rx for the current reception channel,
|
||
rx last for the last reception channel,
|
||
tx for the current transmission channel."
|
||
SYNTAX INTEGER { rx ( 1 ) ,
|
||
rxLast ( 2 ) ,
|
||
tx ( 3 ) }
|
||
|
||
EstimationMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type of Channel estimation process. Two are available:
|
||
- automatic, the equipment negociates the best configuration
|
||
with the remote equipment,
|
||
- manual, the operator defines the configuration."
|
||
SYNTAX INTEGER { automatic ( 1 ) ,
|
||
manual ( 2 ) }
|
||
|
||
GroupValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A band is composed of 16 groups."
|
||
SYNTAX Integer32 ( 1 .. 16 )
|
||
|
||
ResultValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Result value of input vectors."
|
||
SYNTAX INTEGER { success ( 1 ) ,
|
||
fail ( 2 ) }
|
||
|
||
AdaptValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The adapt level integer value."
|
||
SYNTAX Integer32 ( 0 .. 8191 )
|
||
|
||
ChannelBandwidthValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The channel bandwidth integer value."
|
||
SYNTAX Integer32 --PR01
|
||
|
||
SoftwareIndex ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The software index."
|
||
SYNTAX Integer32 ( 1 .. 10 )
|
||
|
||
SoftwareActionResultValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Result value of software action process."
|
||
SYNTAX INTEGER { success ( 0 ) ,
|
||
on-going ( 1 ) ,
|
||
fileNotExist ( 2 ) ,
|
||
flashExhausted ( 3 ),
|
||
flashCorrupted ( 4 ),
|
||
notEnoughMemory ( 5 ),
|
||
invalidParameter ( 6 ),
|
||
genericError ( 7 ) }
|
||
|
||
SoftwareActionType ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Type of software management action."
|
||
SYNTAX INTEGER { switch ( 1 ) ,
|
||
remove ( 2 ) }
|
||
|
||
--PR01 BEGIN
|
||
PlcModeType ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Type of software management action."
|
||
SYNTAX INTEGER { ad-hoc ( 0 ) ,
|
||
slave ( 1 ) ,
|
||
master ( 2 ) }
|
||
--PR01 END
|
||
|
||
-- PLC data
|
||
|
||
plc OBJECT IDENTIFIER
|
||
::= { spc200MIB 1 }
|
||
|
||
-- statistic data
|
||
|
||
stats OBJECT IDENTIFIER
|
||
::= { plc 1 }
|
||
--PR01 BEGIN
|
||
-- protocol OBJECT IDENTIFIER
|
||
-- ::= { stats 1 }
|
||
|
||
-- ip OBJECT IDENTIFIER
|
||
-- ::= { protocol 1 }
|
||
|
||
-- mac OBJECT IDENTIFIER
|
||
-- ::= { protocol 2 }
|
||
|
||
-- plcp OBJECT IDENTIFIER
|
||
-- ::= { protocol 3 }
|
||
|
||
-- ipStatsTable OBJECT-TYPE
|
||
-- SYNTAX SEQUENCE OF IpStatsEntry
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION "This table gathers all statistic data specific to
|
||
-- SPC200 chip relative to IP protocol. The data is
|
||
-- relative to the underlying interface that is under
|
||
-- the IP protocol layer. So the table index is
|
||
-- the ifIndex of such an interface."
|
||
-- ::= { ip 1 }
|
||
|
||
-- ipStatsEntry OBJECT-TYPE
|
||
-- SYNTAX IpStatsEntry
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION "This row contains IP statistic data specific to
|
||
-- SPC200 chip. The data is relevant for the interface
|
||
-- under the IP protocol layer."
|
||
-- INDEX { ifIndex }
|
||
-- ::= { ipStatsTable 1 }
|
||
|
||
-- IpStatsEntry ::= SEQUENCE {
|
||
-- ipInPkts Counter32,
|
||
-- ipInErrorPkts Counter32,
|
||
-- ipOutPkts Counter32,
|
||
-- ipOutErrorPkts Counter32,
|
||
-- ipInBridgedPkts Counter32
|
||
-- }
|
||
|
||
|
||
-- ipInPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of IP packets received by the interface
|
||
-- associated with this entry"
|
||
-- ::= { ipStatsEntry 1 }
|
||
|
||
|
||
-- ipInErrorPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of inbound IP packets that contained
|
||
-- errors preventing them from being deliverable to a
|
||
-- higher -layer protocol on the interface associated
|
||
-- with this entry."
|
||
-- ::= { ipStatsEntry 2 }
|
||
|
||
|
||
-- ipOutPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of outbound IP packets transmitted
|
||
-- out the interface associated with this entry"
|
||
-- ::= { ipStatsEntry 3 }
|
||
|
||
|
||
-- ipOutErrorPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of outbound IP packets that could not be
|
||
-- transmitted because of errors."
|
||
-- ::= { ipStatsEntry 4 }
|
||
|
||
|
||
-- ipInBridgedPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of IP packets bridged from the interface,
|
||
-- associated with this entry, and another one"
|
||
-- ::= { ipStatsEntry 5 }
|
||
|
||
-- ipInPackets OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of IP packets received
|
||
-- by the SPC200 CHIP"
|
||
-- ::= { ip 2 }
|
||
|
||
-- ipInErrorPackets OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of inbound IP packets that
|
||
-- contained errors preventing them from being delivered."
|
||
-- ::= { ip 3 }
|
||
|
||
-- ipOutPackets OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of outbound IP packets transmitted
|
||
-- out the interfaces"
|
||
-- ::= { ip 4 }
|
||
|
||
-- ipOutErrorPackets OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of outbound IP packets that could
|
||
-- not be transmitted because of errors."
|
||
-- ::= { ip 5 }
|
||
|
||
-- ipBridgedPackets OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of IP packets bridged"
|
||
-- ::= { ip 6 }
|
||
|
||
-- macStatsTable OBJECT-TYPE
|
||
-- SYNTAX SEQUENCE OF MacStatsEntry
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION "This table gathers all SPC200 chip specific packet
|
||
-- statistics relative to MAC layer.
|
||
-- The data is relative to the underlying interface
|
||
-- that is under the MAC layer. So the table index is
|
||
-- the ifIndex of such an interface."
|
||
-- ::= { mac 1 }
|
||
|
||
-- macStatsEntry OBJECT-TYPE
|
||
-- SYNTAX MacStatsEntry
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION "This row contains MAC statistic data specific
|
||
-- to SPC200 chip. The data is relevant for the interface
|
||
-- under the MAC layer."
|
||
-- INDEX { ifIndex }
|
||
-- ::= { macStatsTable 1 }
|
||
--
|
||
-- MacStatsEntry ::= SEQUENCE {
|
||
-- macInPkts Counter32,
|
||
-- macInErrorPkts Counter32,
|
||
-- macOutPackets Counter32,
|
||
-- macOutErrorPkts Counter32
|
||
-- }
|
||
|
||
|
||
-- macInPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of MAC packets received by the interface
|
||
-- associated with this entry"
|
||
-- ::= { macStatsEntry 1 }
|
||
--
|
||
--
|
||
-- macInErrorPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of inbound MAC packets that contained
|
||
-- errors preventing them from being deliverable to
|
||
-- a higher -layer protocol on the interface
|
||
-- associated with this entry."
|
||
-- ::= { macStatsEntry 2 }
|
||
|
||
|
||
-- macOutPackets OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of outbound MAC packets transmitted
|
||
-- out the interface associated with this entry"
|
||
-- ::= { macStatsEntry 3 }
|
||
|
||
|
||
-- macOutErrorPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of outbound MAC packets that could not be
|
||
-- transmitted because of errors."
|
||
-- ::= { macStatsEntry 4 }
|
||
|
||
-- plcpStatsTable OBJECT-TYPE
|
||
-- SYNTAX SEQUENCE OF PlcpStatsEntry
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION "This table gathers all SPC200 chip specific packet
|
||
-- statistics relative to PLCP protocol.
|
||
-- The data is relative to the underlying interface that
|
||
-- is under the PLCP protocol layer. So the table index
|
||
-- is the ifIndex of such an interface."
|
||
-- ::= { plcp 1 }
|
||
|
||
-- plcpStatsEntry OBJECT-TYPE
|
||
-- SYNTAX PlcpStatsEntry
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION "This row contains PLCP statistic data specific
|
||
-- to SPC200 chip. The data is relevant for the interface
|
||
-- under the PLCP layer."
|
||
-- INDEX { ifIndex }
|
||
-- ::= { plcpStatsTable 1 }
|
||
|
||
-- PlcpStatsEntry ::= SEQUENCE {
|
||
-- plcpInPkts Counter32,
|
||
-- plcpInErrorPkts Counter32,
|
||
-- plcpOutPkts Counter32,
|
||
-- plcpOutErrorPkts Counter32
|
||
-- }
|
||
|
||
|
||
-- plcpInPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of PLCP packets received by the interface
|
||
-- associated with this entry"
|
||
-- ::= { plcpStatsEntry 1 }
|
||
|
||
|
||
-- plcpInErrorPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of inbound PLCP packets that contained
|
||
-- errors preventing them from being deliverable to a
|
||
-- higher -layer protocol on the interface associated
|
||
-- with this entry."
|
||
-- ::= { plcpStatsEntry 2 }
|
||
|
||
|
||
-- plcpOutPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The total number of outbound PLCP packets transmitted
|
||
-- out the interface associated with this entry"
|
||
-- ::= { plcpStatsEntry 3 }
|
||
|
||
|
||
-- plcpOutErrorPkts OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The number of outbound PLCP packets that could not be
|
||
-- transmitted because of errors."
|
||
-- ::= { plcpStatsEntry 4 }
|
||
--PR01 END
|
||
|
||
|
||
portStatsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PortStatsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table gathers all statistic data specific
|
||
to SPC200 chip relative to plc connection."
|
||
::= { stats 2 }
|
||
|
||
portStatsEntry OBJECT-TYPE
|
||
SYNTAX PortStatsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains statistic data specific to
|
||
SPC200 chip relative to a connection."
|
||
INDEX { plcBasePortIndex,
|
||
portStatsBandIndex,
|
||
portStatsGroupIndex,
|
||
portStatsCarrierIndex }
|
||
::= { portStatsTable 1 }
|
||
|
||
PortStatsEntry ::= SEQUENCE {
|
||
portStatsBandIndex BandValue,
|
||
portStatsGroupIndex GroupValue,
|
||
portStatsCarrierIndex CarrierValue,
|
||
portStatsSignal Counter32,
|
||
portStatsNoise Counter32
|
||
-- portStatsBer Counter32
|
||
}
|
||
|
||
|
||
portStatsBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the signal,
|
||
noise, ber data are collected."
|
||
::= { portStatsEntry 1 }
|
||
|
||
|
||
portStatsGroupIndex OBJECT-TYPE
|
||
SYNTAX GroupValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The group number on which the signal,
|
||
noise, ber data are collected"
|
||
::= { portStatsEntry 2 }
|
||
|
||
|
||
portStatsCarrierIndex OBJECT-TYPE
|
||
SYNTAX CarrierValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The group number on which the signal,
|
||
noise, ber data are collected"
|
||
::= { portStatsEntry 3 }
|
||
|
||
|
||
portStatsSignal OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The DB value of the signal associated
|
||
with the carrier wave entry."
|
||
::= { portStatsEntry 4 }
|
||
|
||
|
||
portStatsNoise OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The DB value of the noise associated
|
||
with the carrier wave entry."
|
||
::= { portStatsEntry 5 }
|
||
--PR01 BEGIN
|
||
-- portStatsBer OBJECT-TYPE
|
||
-- SYNTAX Counter32
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The BER value * 100 associated
|
||
-- with the carrier wave entry."
|
||
-- ::= { portStatsEntry 6 }
|
||
--PR01 END
|
||
|
||
portStats2Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PortStats2Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table gathers all statistic data specific to
|
||
SPC200 chip relative to plc channels. This table has
|
||
the same information as the portChannelStatsTable
|
||
but in a more compact way. This table has been added
|
||
to deal with possible slow performances."
|
||
::= { stats 3 }
|
||
|
||
portStats2Entry OBJECT-TYPE
|
||
SYNTAX PortStats2Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains statistic data specific to
|
||
SPC200 chip relative to a connection."
|
||
INDEX { plcBasePortIndex,
|
||
plcModBandIndex }
|
||
::= { portStats2Table 1 }
|
||
|
||
PortStats2Entry ::= SEQUENCE {
|
||
portStats2Signal OCTET STRING,
|
||
portStats2Noise OCTET STRING,
|
||
|
||
|
||
--PR01 BEGIN
|
||
-- portStats2Ber OCTET STRING,
|
||
portStats2AvgBandAtt Counter32,
|
||
portStats2AvgBandSNR Counter32
|
||
--PR01 END
|
||
}
|
||
|
||
|
||
portStats2Signal OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The values of the signal for all the carrier waves.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is coded on two bytes.
|
||
There is one value for each 128 carriers of the
|
||
considered band."
|
||
::= { portStats2Entry 1 }
|
||
|
||
|
||
portStats2Noise OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The values of the noise for all the carrier waves.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is coded on two bytes.
|
||
There is one value for each 128 carriers of the
|
||
considered band."
|
||
::= { portStats2Entry 2 }
|
||
|
||
-- portStats2Ber OBJECT-TYPE
|
||
-- SYNTAX OCTET STRING
|
||
-- MAX-ACCESS read-only
|
||
-- STATUS current
|
||
-- DESCRIPTION "The values of the signal for all the carrier waves.
|
||
-- The expected format is VALUE VALUE VALUE ... VALUE.
|
||
-- Each value is coded on two bytes.
|
||
-- There is one value for each 128 carriers of the
|
||
-- considered band.
|
||
-- The VALUE represents the BER value * 10000."
|
||
-- ::= { portStats2Entry 3 }
|
||
|
||
--PR01 BEGIN
|
||
portStats2AvgBandAtt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Average attenuation per band (dB)."
|
||
::= { portStats2Entry 3 }
|
||
|
||
|
||
portStats2AvgBandSNR OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Average SNR per band (dB)."
|
||
::= { portStats2Entry 4 }
|
||
--PR01 END
|
||
--PR01 BEGIN
|
||
portStats3Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PortStats3Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table gathers all statistic data specific to
|
||
SPC200 chip relative to plc channels. This table has
|
||
the same information as the portChannelStatsTable
|
||
but in a more compact way. This table has been added
|
||
to deal with possible slow performances."
|
||
::= { stats 4 }
|
||
|
||
portStats3Entry OBJECT-TYPE
|
||
SYNTAX PortStats3Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains statistic data specific to
|
||
SPC200 chip relative to a connection."
|
||
INDEX { plcBasePortIndex }
|
||
::= { portStats3Table 1 }
|
||
|
||
PortStats3Entry ::= SEQUENCE {
|
||
portStats3AvgAtt Counter32,
|
||
portStats3AvgSNR Counter32
|
||
}
|
||
|
||
portStats3AvgAtt OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Average attenuation on the link (dB)."
|
||
::= { portStats3Entry 1 }
|
||
|
||
portStats3AvgSNR OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Average SNR on the link (dB)."
|
||
::= { portStats3Entry 2 }
|
||
|
||
bootstats OBJECT-IDENTITY
|
||
STATUS current
|
||
DESCRIPTION "boot statistics"
|
||
::= { stats 5 }
|
||
|
||
bootstatsBoot OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Boot"
|
||
::= { bootstats 1 }
|
||
|
||
bootstatsManualReset OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Manual reset"
|
||
::= { bootstats 2 }
|
||
|
||
bootstatsFailureReset OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Failure reset"
|
||
::= { bootstats 3 }
|
||
|
||
--PR01 END
|
||
|
||
-- configuration data
|
||
plcObjects OBJECT IDENTIFIER
|
||
::= { plc 2 }
|
||
|
||
plcMode OBJECT-TYPE -- PR01
|
||
SYNTAX PlcModeType --PR01
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Plc Mode"
|
||
::= { plcObjects 1 }
|
||
|
||
plcTopo OBJECT IDENTIFIER
|
||
::= { plcObjects 2 }
|
||
|
||
plcNodeConfiguration OBJECT IDENTIFIER
|
||
::= { plcObjects 3 }
|
||
|
||
--PR01 BEGIN
|
||
plcSNAnalyser OBJECT IDENTIFIER
|
||
::= { plcObjects 4 }
|
||
|
||
plcSNAnalyserEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { true ( 1 ) ,
|
||
false ( 2 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "true if the modem should turn to spectrum analyser mode.
|
||
In this mode the modem enters a receive only mode,
|
||
and captures periodic samples of the signal on the powerline.
|
||
The spectrum analyser mode shall be disabled for normal
|
||
powerline modem operation."
|
||
::= { plcSNAnalyser 1 }
|
||
|
||
plcSNAnalyserTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcSNAnalyserEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table gathers all statistic data specific to
|
||
SPC200 chip relative to plc analyser."
|
||
::= { plcSNAnalyser 2 }
|
||
|
||
plcSNAnalyserEntry OBJECT-TYPE
|
||
SYNTAX PlcSNAnalyserEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains statistic data specific to
|
||
SPC200 chip relative to a band."
|
||
INDEX { plcModBandIndex }
|
||
::= { plcSNAnalyserTable 1 }
|
||
|
||
PlcSNAnalyserEntry ::= SEQUENCE {
|
||
plcSNAnalyserMinSignal OCTET STRING,
|
||
plcSNAnalyserMaxSignal OCTET STRING,
|
||
plcSNAnalyserAvgSignal OCTET STRING,
|
||
plcSNAnalyserLastSignal OCTET STRING,
|
||
plcSNAnalyserFFTDiv Counter32
|
||
}
|
||
|
||
plcSNAnalyserMinSignal OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Minimum signal measured over several samples for the
|
||
associated carrier wave entry. The value is expressed
|
||
in Glomer<65> which can be converted in dBm/Hz using the
|
||
following formula: dBm/Hz = 19*log10(Glomer<65>) - 113"
|
||
::= { plcSNAnalyserEntry 1 }
|
||
|
||
|
||
plcSNAnalyserMaxSignal OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Maximum signal measured on several samples for the
|
||
associated carrier wave entry. The value is expressed
|
||
in Glomer<65> which can be converted in dBm/Hz using the
|
||
following formula: dBm/Hz = 19*log10(Glomer<65>) - 113"
|
||
::= { plcSNAnalyserEntry 2 }
|
||
|
||
|
||
plcSNAnalyserAvgSignal OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Average signal measured on several samples for the
|
||
associated carrier wave entry. The value is expressed
|
||
in Glomer<65> which can be converted in dBm/Hz using the
|
||
following formula: dBm/Hz = 19*log10(Glomer<65>) - 113"
|
||
::= { plcSNAnalyserEntry 3 }
|
||
|
||
plcSNAnalyserLastSignal OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Signal measured for last sample on the associated
|
||
carrier wave entry. The value is expressed
|
||
in Glomer<65> which can be converted in dBm/Hz using the
|
||
following formula: dBm/Hz = 19*log10(Glomer<65>) - 113"
|
||
::= { plcSNAnalyserEntry 4 }
|
||
|
||
plcSNAnalyserFFTDiv OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "FFT division factor on the associated band."
|
||
::= { plcSNAnalyserEntry 5 }
|
||
|
||
plcSNAnalyserAGC OBJECT-TYPE
|
||
SYNTAX Integer32 ( 0..255 )
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Gain factor in dB, as used by the
|
||
Automatic Gain Control last sample"
|
||
::= { plcSNAnalyser 3 }
|
||
|
||
|
||
plcAGCAnalyser OBJECT IDENTIFIER
|
||
::= { plcObjects 5 }
|
||
|
||
plcAGCAnalyserEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { true ( 1 ) ,
|
||
false ( 2 ) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION " "
|
||
::= { plcAGCAnalyser 1 }
|
||
|
||
plcAGCAnalyserSamplesPart1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION " "
|
||
::= { plcAGCAnalyser 2 }
|
||
|
||
plcAGCAnalyserSamplesPart2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION " "
|
||
::= { plcAGCAnalyser 3 }
|
||
--PR01 END
|
||
|
||
plcTopoChanges OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The total number of topology changes detected
|
||
by this plc bridge since the management entity
|
||
was last reset or initialized. Such changes
|
||
concerns only
|
||
- the plcBasePortTable rows
|
||
- the plcBasePortTable columns
|
||
except for plcBasePortChannelEstimation"
|
||
::= { plcTopo 1 }
|
||
|
||
plcBasePortTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcBasePortEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains the list of plc remote connection"
|
||
::= { plcTopo 2 }
|
||
|
||
plcBasePortEntry OBJECT-TYPE
|
||
SYNTAX PlcBasePortEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains plc remote connection information"
|
||
INDEX { plcBasePortIndex }
|
||
::= { plcBasePortTable 1 }
|
||
|
||
PlcBasePortEntry ::= SEQUENCE {
|
||
plcBasePortIndex MacAddress,
|
||
plcBasePortAddress MacAddress,
|
||
plcBasePortChannelEstimation EstimationMode,
|
||
plcBasePortAttenuation Counter32 }
|
||
|
||
|
||
plcBasePortIndex OBJECT-TYPE
|
||
SYNTAX MacAddress
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The MAC address of the MAC layer above
|
||
the plc interface of the remote PLC equipment."
|
||
::= { plcBasePortEntry 1 }
|
||
|
||
|
||
plcBasePortAddress OBJECT-TYPE
|
||
SYNTAX MacAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The MAC address of the MAC layer above
|
||
the plc interface of the remote PLC equipment."
|
||
::= { plcBasePortEntry 2 }
|
||
|
||
|
||
plcBasePortChannelEstimation OBJECT-TYPE
|
||
SYNTAX EstimationMode
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Enable or disable the automatic channel
|
||
estimation processus."
|
||
::= { plcBasePortEntry 3 }
|
||
|
||
plcBasePortAttenuation OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Link attenuation (dB)."
|
||
::= { plcBasePortEntry 4 }
|
||
|
||
|
||
plcChannelModulationStringTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcChannelModulationStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains string values for a quick access to
|
||
the modulation amplitude configurations of all active
|
||
channels."
|
||
::= { plcTopo 3 }
|
||
|
||
|
||
plcChannelModulationStringEntry OBJECT-TYPE
|
||
SYNTAX PlcChannelModulationStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains string values for a quick access to
|
||
the modulation amplitude configuration
|
||
of each active channel of the remote
|
||
connection referenced by plcBasePortIndex."
|
||
INDEX { plcBasePortIndex }
|
||
::= { plcChannelModulationStringTable 1 }
|
||
|
||
|
||
PlcChannelModulationStringEntry ::= SEQUENCE {
|
||
plcRxChannelModulation OCTET STRING,
|
||
plcRxLastChannelModulation OCTET STRING,
|
||
plcTxChannelModulation OCTET STRING }
|
||
|
||
|
||
plcRxChannelModulation OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude values for the Rx channel of
|
||
a given remote connection entry.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is an octet representing two modulation values.
|
||
Each modulation is coded on 4 bits.
|
||
There are ( 16 groups * 7 bands ) / 2 = 66 values."
|
||
::= { plcChannelModulationStringEntry 1 }
|
||
|
||
|
||
plcRxLastChannelModulation OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude values for the Rx Last channel of
|
||
a given remote connection entry.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is an octet representing two modulation values.
|
||
Each modulation is coded on 4 bits representing ModulationValue - 1.
|
||
There are ( 16 groups * 7 bands ) / 2 = 66 values."
|
||
::= { plcChannelModulationStringEntry 2 }
|
||
|
||
plcTxChannelModulation OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude values for the Tx channel of
|
||
a given remote connection entry.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is an octet representing two modulation values.
|
||
Each modulation is coded on 4 bits.
|
||
There are ( 16 groups * 7 bands ) / 2 = 66 values."
|
||
::= { plcChannelModulationStringEntry 3 }
|
||
|
||
|
||
plcChannelModulationTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcChannelModulationEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains the modulation amplitude
|
||
configuration of all active channels."
|
||
::= { plcTopo 4 }
|
||
|
||
|
||
plcChannelModulationEntry OBJECT-TYPE
|
||
SYNTAX PlcChannelModulationEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains modulation amplitude configuration
|
||
of the channel, referenced by the plcPortChannelIndex,
|
||
of the remote connection referenced by
|
||
plcBasePortIndex."
|
||
INDEX { plcBasePortIndex,
|
||
plcPortChannelIndex,
|
||
plcModBandIndex }
|
||
::= { plcChannelModulationTable 1 }
|
||
|
||
PlcChannelModulationEntry ::= SEQUENCE {
|
||
plcModBandIndex BandValue,
|
||
plcModGroup1 ModulationValue,
|
||
plcModGroup2 ModulationValue,
|
||
plcModGroup3 ModulationValue,
|
||
plcModGroup4 ModulationValue,
|
||
plcModGroup5 ModulationValue,
|
||
plcModGroup6 ModulationValue,
|
||
plcModGroup7 ModulationValue,
|
||
plcModGroup8 ModulationValue,
|
||
plcModGroup9 ModulationValue,
|
||
plcModGroup10 ModulationValue,
|
||
plcModGroup11 ModulationValue,
|
||
plcModGroup12 ModulationValue,
|
||
plcModGroup13 ModulationValue,
|
||
plcModGroup14 ModulationValue,
|
||
plcModGroup15 ModulationValue,
|
||
plcModGroup16 ModulationValue
|
||
}
|
||
|
||
|
||
plcModBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number of which the modulations are defined"
|
||
::= { plcChannelModulationEntry 1 }
|
||
|
||
|
||
plcModGroup1 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the first group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 2 }
|
||
|
||
|
||
plcModGroup2 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the second group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 3 }
|
||
|
||
|
||
plcModGroup3 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the third group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 4 }
|
||
|
||
|
||
plcModGroup4 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the fourth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 5 }
|
||
|
||
|
||
plcModGroup5 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the fifth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 6 }
|
||
|
||
|
||
plcModGroup6 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the sixth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 7 }
|
||
|
||
|
||
plcModGroup7 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the seventh group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 8 }
|
||
|
||
|
||
plcModGroup8 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the eighth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 9 }
|
||
|
||
|
||
plcModGroup9 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the nineth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 10 }
|
||
|
||
|
||
plcModGroup10 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the tenth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 11 }
|
||
|
||
|
||
plcModGroup11 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the eleventh group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 12 }
|
||
|
||
|
||
plcModGroup12 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the twelveth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 13 }
|
||
|
||
|
||
plcModGroup13 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the thirteenth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 14 }
|
||
|
||
|
||
plcModGroup14 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the fourteenth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 15 }
|
||
|
||
|
||
plcModGroup15 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the fifteenth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 16 }
|
||
|
||
|
||
plcModGroup16 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The modulation amplitude of the sixteenth group
|
||
of the band entry of the channel entry
|
||
for a given remote connection entry."
|
||
::= { plcChannelModulationEntry 17 }
|
||
|
||
|
||
plcChannelModulationInput OBJECT IDENTIFIER
|
||
::= { plcTopo 5 }
|
||
|
||
plcModulationInputAddr OBJECT-TYPE
|
||
SYNTAX MacAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The MAC address of the MAC layer above
|
||
the plc interface of the remote
|
||
PLC equipment for which the modulation
|
||
value changes are requested."
|
||
::= { plcChannelModulationInput 1 }
|
||
|
||
plcModulationInputChannel OBJECT-TYPE
|
||
SYNTAX PlcChannelType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The channel type of the remote PLC equipment
|
||
for which the modulation value changes
|
||
are requested."
|
||
::= { plcChannelModulationInput 2 }
|
||
|
||
plcModulationInputBand OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The band number of which the modulation value
|
||
changes are requested."
|
||
::= { plcChannelModulationInput 3 }
|
||
|
||
plcInputModulationGroup1 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
first group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 4 }
|
||
|
||
plcInputModulationGroup2 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
second group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 5 }
|
||
|
||
plcInputModulationGroup3 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
third group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 6 }
|
||
|
||
plcInputModulationGroup4 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
fourth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 7 }
|
||
|
||
plcInputModulationGroup5 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
fifth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 8 }
|
||
|
||
plcInputModulationGroup6 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
sixth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 9 }
|
||
|
||
plcInputModulationGroup7 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
seventh group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 10 }
|
||
|
||
plcInputModulationGroup8 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
eighth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 11 }
|
||
|
||
plcInputModulationGroup9 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
nineth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 12 }
|
||
|
||
plcInputModulationGroup10 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
tenth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 13 }
|
||
|
||
plcInputModulationGroup11 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
eleventh group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 14 }
|
||
|
||
plcInputModulationGroup12 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
twelveth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 15 }
|
||
|
||
plcInputModulationGroup13 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
thirteenth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 16 }
|
||
|
||
plcInputModulationGroup14 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
fourteenth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 17 }
|
||
|
||
plcInputModulationGroup15 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
fifteenth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 18 }
|
||
|
||
plcInputModulationGroup16 OBJECT-TYPE
|
||
SYNTAX ModulationValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The new requested modulation amplitude of the
|
||
sixteenth group of the considered band and
|
||
channel input values."
|
||
::= { plcChannelModulationInput 19 }
|
||
|
||
|
||
plcModulationInputProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request a modification of all the modulations
|
||
associated to a band and a channel of a remote
|
||
PLC equipment."
|
||
::= { plcChannelModulationInput 20 }
|
||
|
||
plcModulationInputResult OBJECT-TYPE
|
||
SYNTAX ResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested modulation value changes."
|
||
::= { plcChannelModulationInput 21 }
|
||
|
||
plcPortChannelTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcPortChannelEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains the list of plc channels"
|
||
::= { plcTopo 6 }
|
||
|
||
plcPortChannelEntry OBJECT-TYPE
|
||
SYNTAX PlcPortChannelEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains plc channel information"
|
||
INDEX { plcBasePortIndex, plcPortChannelIndex }
|
||
::= { plcPortChannelTable 1 }
|
||
|
||
PlcPortChannelEntry ::= SEQUENCE {
|
||
plcPortChannelIndex Unsigned32,
|
||
plcPortChannelType PlcChannelType,
|
||
plcPortChannelGain Integer32,
|
||
plcPortChannelBandwidth ChannelBandwidthValue,
|
||
plcPortChannelMaxBandwidth ChannelBandwidthValue,
|
||
plcPortChannelSynchronizationBand BandValue
|
||
}
|
||
|
||
|
||
plcPortChannelIndex OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The channel number belongs to the remote connection
|
||
with plc equipment associated with the
|
||
plcBasePortIndex value.
|
||
Only three channels are expected.
|
||
Index 1 for RX channel
|
||
Index 2 for RXLast channel
|
||
index 3 for TX channel"
|
||
::= { plcPortChannelEntry 1 }
|
||
|
||
|
||
plcPortChannelType OBJECT-TYPE
|
||
SYNTAX PlcChannelType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The channel type."
|
||
::= { plcPortChannelEntry 2 }
|
||
|
||
|
||
plcPortChannelGain OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The gain associated with the channel."
|
||
::= { plcPortChannelEntry 3 }
|
||
|
||
plcPortChannelBandwidth OBJECT-TYPE
|
||
SYNTAX ChannelBandwidthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The bandwidth of the channel in Kbit/s."
|
||
::= { plcPortChannelEntry 4 }
|
||
|
||
--PR01 BEGIN
|
||
plcPortChannelMaxBandwidth OBJECT-TYPE
|
||
SYNTAX ChannelBandwidthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The maximum bandwidth of the channel in Kbit/s."
|
||
::= { plcPortChannelEntry 5 }
|
||
--PR01 END
|
||
|
||
plcPortChannelSynchronizationBand OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The synchronization band used for this channel."
|
||
::= { plcPortChannelEntry 6 }
|
||
|
||
plcChannelPilotStringTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcChannelPilotStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains the string values representing
|
||
of pilot values of all active channels."
|
||
::= { plcTopo 7 }
|
||
|
||
|
||
plcChannelPilotStringEntry OBJECT-TYPE
|
||
SYNTAX PlcChannelPilotStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains a quick access for pilot values ,
|
||
of the remote connection referenced by
|
||
plcBasePortIndex."
|
||
INDEX { plcBasePortIndex }
|
||
::= { plcChannelPilotStringTable 1 }
|
||
|
||
|
||
PlcChannelPilotStringEntry ::= SEQUENCE {
|
||
plcRxChannelPilots OCTET STRING,
|
||
plcRxLastChannelPilots OCTET STRING,
|
||
plcTxChannelPilots OCTET STRING}
|
||
|
||
|
||
plcRxChannelPilots OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave numbers which support
|
||
the pilot waves for the Rx Channel.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is a pair of octets representing the pilot
|
||
values. There is one pair (pilot1 pilot2) for each
|
||
of the 7 bands."
|
||
::= { plcChannelPilotStringEntry 1 }
|
||
|
||
|
||
plcRxLastChannelPilots OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave numbers which support
|
||
the pilot waves for the Rx Last Channel.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is a pair of octets representing the pilot
|
||
values. There is one pair (pilot1 pilot2) for each
|
||
of the 7 bands."
|
||
::= { plcChannelPilotStringEntry 2 }
|
||
|
||
|
||
plcTxChannelPilots OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave numbers which support
|
||
the pilot waves for the Tx Channel.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is a pair of octets representing the pilot
|
||
values. There is one pair (pilot1 pilot2) for each
|
||
of the 7 bands."
|
||
::= { plcChannelPilotStringEntry 3 }
|
||
|
||
|
||
plcChannelPilotsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcChannelPilotsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This tabel contains pilots configuration
|
||
for each plc channel."
|
||
::= { plcTopo 8 }
|
||
|
||
|
||
plcChannelPilotsEntry OBJECT-TYPE
|
||
SYNTAX PlcChannelPilotsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains the pilots 1 and 2 configuration
|
||
for a channel defined by the
|
||
couple (plcBasePortIndex, plcPortChannelIndex)"
|
||
INDEX { plcBasePortIndex,
|
||
plcPortChannelIndex,
|
||
plcChannelPilotBandIndex }
|
||
::= { plcChannelPilotsTable 1 }
|
||
|
||
PlcChannelPilotsEntry ::= SEQUENCE {
|
||
plcChannelPilotBandIndex BandValue,
|
||
plcChannelPilot1 PilotValue,
|
||
plcChannePilot2 PilotValue
|
||
}
|
||
|
||
|
||
plcChannelPilotBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the pilots are defined."
|
||
::= { plcChannelPilotsEntry 1 }
|
||
|
||
|
||
plcChannelPilot1 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave number which supports
|
||
the first pilot wave for the channel
|
||
associated with this entry."
|
||
::= { plcChannelPilotsEntry 2 }
|
||
|
||
|
||
plcChannePilot2 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave number which supports
|
||
the second pilot wave for the channel
|
||
associated with this entry."
|
||
::= { plcChannelPilotsEntry 3 }
|
||
|
||
|
||
plcChannelPilotsInput OBJECT IDENTIFIER
|
||
::= { plcTopo 9 }
|
||
|
||
plcPilotsInputAddr OBJECT-TYPE
|
||
SYNTAX MacAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The MAC address of the MAC layer above
|
||
the plc interface of the remote
|
||
PLC equipment for which the pilot
|
||
value changes are requested."
|
||
::= { plcChannelPilotsInput 1 }
|
||
|
||
plcPilotsInputChannel OBJECT-TYPE
|
||
SYNTAX PlcChannelType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The channel type of the remote PLC equipment
|
||
for which the pilot value changes
|
||
are requested."
|
||
::= { plcChannelPilotsInput 2 }
|
||
|
||
plcPilotsInputBand OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The band number of which the pilots value
|
||
changes are requested."
|
||
::= { plcChannelPilotsInput 3 }
|
||
|
||
|
||
plcInputChannelPilot1 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave number which supports
|
||
the first pilot wave for the considered band and
|
||
channel input values."
|
||
::= { plcChannelPilotsInput 4 }
|
||
|
||
plcInputChannelPilot2 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The carrier wave number which supports
|
||
the second pilot wave for the considered band and
|
||
channel input values."
|
||
::= { plcChannelPilotsInput 5 }
|
||
|
||
plcPilotsInputProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request a modification of the first and second pilot
|
||
associated to a band and a channel of a remote
|
||
PLC equipment."
|
||
::= { plcChannelPilotsInput 6 }
|
||
|
||
plcPilotsInputResult OBJECT-TYPE
|
||
SYNTAX ResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested pilot values changes."
|
||
::= { plcChannelPilotsInput 7 }
|
||
|
||
plcNodeNotches OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The values of the notches for all the node bands.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is an octet representing the 8 notches of
|
||
each group. There is one value for each 7 * 16 bands."
|
||
::= { plcNodeConfiguration 1 }
|
||
|
||
plcNodeNotchesTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcNodeNotchesEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains Notches configuration
|
||
for the SPC200 chip."
|
||
::= { plcNodeConfiguration 2 }
|
||
|
||
plcNodeNotchesEntry OBJECT-TYPE
|
||
SYNTAX PlcNodeNotchesEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains Notches configuration for a group.
|
||
The group is defined by the couple
|
||
(plcNodeNotchesGroupIndex, plcNodeNotchesBandIndex)."
|
||
INDEX { plcNodeNotchesBandIndex, plcNodeNotchesGroupIndex }
|
||
::= { plcNodeNotchesTable 1 }
|
||
|
||
PlcNodeNotchesEntry ::= SEQUENCE {
|
||
plcNodeNotchesBandIndex BandValue,
|
||
plcNodeNotchesGroupIndex GroupValue,
|
||
plcNodeNotchesCarrier1 TruthValue,
|
||
plcNodeNotchesCarrier2 TruthValue,
|
||
plcNodeNotchesCarrier3 TruthValue,
|
||
plcNodeNotchesCarrier4 TruthValue,
|
||
plcNodeNotchesCarrier5 TruthValue,
|
||
plcNodeNotchesCarrier6 TruthValue,
|
||
plcNodeNotchesCarrier7 TruthValue,
|
||
plcNodeNotchesCarrier8 TruthValue
|
||
}
|
||
|
||
|
||
plcNodeNotchesBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the notches are defined."
|
||
::= { plcNodeNotchesEntry 1 }
|
||
|
||
|
||
plcNodeNotchesGroupIndex OBJECT-TYPE
|
||
SYNTAX GroupValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The group number on which the notches are defined."
|
||
::= { plcNodeNotchesEntry 2 }
|
||
|
||
|
||
plcNodeNotchesCarrier1 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the first carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 3 }
|
||
|
||
|
||
plcNodeNotchesCarrier2 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the second carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 4 }
|
||
|
||
|
||
plcNodeNotchesCarrier3 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the third carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 5 }
|
||
|
||
|
||
plcNodeNotchesCarrier4 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the fourth carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 6 }
|
||
|
||
|
||
plcNodeNotchesCarrier5 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the fifth carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 7 }
|
||
|
||
|
||
plcNodeNotchesCarrier6 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the sixth carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 8 }
|
||
|
||
|
||
plcNodeNotchesCarrier7 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the seventh carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 9 }
|
||
|
||
|
||
plcNodeNotchesCarrier8 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Tell if the eighth carrier of the group entry
|
||
of the band entry is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesEntry 10 }
|
||
|
||
plcNodeNotchesInput OBJECT IDENTIFIER
|
||
::= { plcNodeConfiguration 3 }
|
||
|
||
plcNodeNotchesInputBand OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the notches value
|
||
changes are requested."
|
||
::= { plcNodeNotchesInput 1 }
|
||
|
||
|
||
plcNodeNotchesInputGroup OBJECT-TYPE
|
||
SYNTAX GroupValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The group number on which the notches value
|
||
changes are requested."
|
||
::= { plcNodeNotchesInput 2 }
|
||
|
||
plcNodeNotchesInputCarrier1 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The first carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 3 }
|
||
|
||
plcNodeNotchesInputCarrier2 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The second carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 4 }
|
||
|
||
plcNodeNotchesInputCarrier3 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The third carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 5 }
|
||
|
||
plcNodeNotchesInputCarrier4 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The fourth carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 6 }
|
||
|
||
plcNodeNotchesInputCarrier5 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The eighth carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 7 }
|
||
|
||
plcNodeNotchesInputCarrier6 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The eighth carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 8 }
|
||
|
||
plcNodeNotchesInputCarrier7 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The seventh carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 9 }
|
||
|
||
plcNodeNotchesInputCarrier8 OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The eighth carrier of the considered group and
|
||
band is a notch carrier.
|
||
The true value means the current carrier is a notch."
|
||
::= { plcNodeNotchesInput 10 }
|
||
|
||
plcNodeNotchesInputProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request a modification of the carrier notches
|
||
associated to the considered group and
|
||
band."
|
||
::= { plcNodeNotchesInput 11 }
|
||
|
||
plcNodeNotchesInputResult OBJECT-TYPE
|
||
SYNTAX ResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested node carrier notches value changes."
|
||
::= { plcNodeNotchesInput 12 }
|
||
|
||
|
||
plcNodePilots OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The values of the pilot for all the node bands.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is a pair of octets representing the pilot
|
||
values. There is one pair (pilot1 pilot2) for each
|
||
of the 7 bands."
|
||
::= { plcNodeConfiguration 4 }
|
||
|
||
plcNodePilotsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcNodePilotsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains pilot values
|
||
used by default on all channels."
|
||
::= { plcNodeConfiguration 5 }
|
||
|
||
plcNodePilotsEntry OBJECT-TYPE
|
||
SYNTAX PlcNodePilotsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains pilot values
|
||
used by default on a band.
|
||
The band is defined by the index
|
||
plcNodePilotsBandIndex."
|
||
INDEX { plcNodePilotsBandIndex }
|
||
::= { plcNodePilotsTable 1 }
|
||
|
||
PlcNodePilotsEntry ::= SEQUENCE {
|
||
plcNodePilotsBandIndex BandValue,
|
||
plcNodePilot1 PilotValue,
|
||
plcNodePilot2 PilotValue
|
||
}
|
||
|
||
|
||
plcNodePilotsBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the pilot values are defined."
|
||
::= { plcNodePilotsEntry 1 }
|
||
|
||
|
||
plcNodePilot1 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The default carrier wave number
|
||
which supports the first pilot wave."
|
||
::= { plcNodePilotsEntry 2 }
|
||
|
||
|
||
plcNodePilot2 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The default carrier wave number
|
||
which supports the second pilot wave."
|
||
::= { plcNodePilotsEntry 3 }
|
||
|
||
|
||
plcNodePilotsInput OBJECT IDENTIFIER
|
||
::= { plcNodeConfiguration 6 }
|
||
|
||
plcNodePilotsInputBand OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the pilot values
|
||
changes are requested."
|
||
::= { plcNodePilotsInput 1 }
|
||
|
||
|
||
plcInputNodePilot1 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The default carrier wave number
|
||
which supports the first pilot wave of
|
||
the considered band."
|
||
::= { plcNodePilotsInput 2 }
|
||
|
||
plcInputNodePilot2 OBJECT-TYPE
|
||
SYNTAX PilotValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The default carrier wave number
|
||
which supports the second pilot wave of
|
||
the considered band."
|
||
::= { plcNodePilotsInput 3 }
|
||
|
||
|
||
plcNodePilotsInputProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request a modification of the pilot values
|
||
associated to the considered band."
|
||
::= { plcNodePilotsInput 4 }
|
||
|
||
plcNodePilotsInputResult OBJECT-TYPE
|
||
SYNTAX ResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested node pilot values changes."
|
||
::= { plcNodePilotsInput 5 }
|
||
|
||
plcNodeAdaptsStringTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcNodeAdaptsStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains string values for a
|
||
quick access to the adapt configurations
|
||
of all the carriers."
|
||
::= { plcNodeConfiguration 7 }
|
||
|
||
|
||
plcNodeAdaptsStringEntry OBJECT-TYPE
|
||
SYNTAX PlcNodeAdaptsStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains string values for a quick access to
|
||
the adapt configuration
|
||
of each carrier of a band."
|
||
INDEX { plcBasePortIndex , plcNodeAdaptsStringBandIndex }
|
||
::= { plcNodeAdaptsStringTable 1 }
|
||
|
||
PlcNodeAdaptsStringEntry ::= SEQUENCE {
|
||
plcNodeAdaptsStringBandIndex BandValue,
|
||
plcNodeAdaptsStringBand OCTET STRING }
|
||
|
||
plcNodeAdaptsStringBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the adapt values are defined."
|
||
::= { plcNodeAdaptsStringEntry 1 }
|
||
|
||
plcNodeAdaptsStringBand OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt values of the 128 carriers of a band.
|
||
The expected format is VALUE VALUE VALUE ... VALUE.
|
||
Each value is two octets representing one adapt carrier
|
||
level.
|
||
There are ( 16 groups * 8 carriers) = 128 values."
|
||
::= { plcNodeAdaptsStringEntry 2 }
|
||
|
||
plcNodeAdaptsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcNodeAdaptsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains adapt level configuration
|
||
for each carrier of the node."
|
||
::= { plcNodeConfiguration 8 }
|
||
|
||
plcNodeAdaptsEntry OBJECT-TYPE
|
||
SYNTAX PlcNodeAdaptsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains adapt level values
|
||
for a group of carriers.
|
||
The group is defined by the couple
|
||
(plcNodeAdaptsBandIndex,plcNodeAdaptsGroupIndex)."
|
||
INDEX { plcNodeAdaptsBandIndex,plcNodeAdaptsGroupIndex }
|
||
::= { plcNodeAdaptsTable 1 }
|
||
|
||
PlcNodeAdaptsEntry ::= SEQUENCE {
|
||
plcNodeAdaptsBandIndex BandValue,
|
||
plcNodeAdaptsGroupIndex GroupValue,
|
||
plcNodeAdaptsCarrier1 AdaptValue,
|
||
plcNodeAdaptsCarrier2 AdaptValue,
|
||
plcNodeAdaptsCarrier3 AdaptValue,
|
||
plcNodeAdaptsCarrier4 AdaptValue,
|
||
plcNodeAdaptsCarrier5 AdaptValue,
|
||
plcNodeAdaptsCarrier6 AdaptValue,
|
||
plcNodeAdaptsCarrier7 AdaptValue,
|
||
plcNodeAdaptsCarrier8 AdaptValue
|
||
}
|
||
|
||
|
||
plcNodeAdaptsBandIndex OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the adapt values are defined."
|
||
::= { plcNodeAdaptsEntry 1 }
|
||
|
||
plcNodeAdaptsGroupIndex OBJECT-TYPE
|
||
SYNTAX GroupValue
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The group number on which the adapt values are defined."
|
||
::= { plcNodeAdaptsEntry 2 }
|
||
|
||
plcNodeAdaptsCarrier1 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the first carrier of the group."
|
||
::= { plcNodeAdaptsEntry 3 }
|
||
|
||
plcNodeAdaptsCarrier2 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the second carrier of the group."
|
||
::= { plcNodeAdaptsEntry 4 }
|
||
|
||
plcNodeAdaptsCarrier3 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the third carrier of the group."
|
||
::= { plcNodeAdaptsEntry 5 }
|
||
|
||
plcNodeAdaptsCarrier4 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the fourth carrier of the group."
|
||
::= { plcNodeAdaptsEntry 6 }
|
||
|
||
plcNodeAdaptsCarrier5 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the fifth carrier of the group."
|
||
::= { plcNodeAdaptsEntry 7 }
|
||
|
||
plcNodeAdaptsCarrier6 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the sixth carrier of the group."
|
||
::= { plcNodeAdaptsEntry 8 }
|
||
|
||
plcNodeAdaptsCarrier7 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the seventh carrier of the group."
|
||
::= { plcNodeAdaptsEntry 9 }
|
||
|
||
plcNodeAdaptsCarrier8 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the eighth carrier of the group."
|
||
::= { plcNodeAdaptsEntry 10 }
|
||
|
||
plcNodeAdaptsInput OBJECT IDENTIFIER
|
||
::= { plcNodeConfiguration 9 }
|
||
|
||
plcNodeAdaptsInputBand OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The band number on which the adapt level value
|
||
changes are requested."
|
||
::= { plcNodeAdaptsInput 1 }
|
||
|
||
|
||
plcNodeAdaptsInputGroup OBJECT-TYPE
|
||
SYNTAX GroupValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The group number on which the adapt level value
|
||
changes are requested."
|
||
::= { plcNodeAdaptsInput 2 }
|
||
|
||
plcNodeAdaptsInputCarrier1 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the first carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 3 }
|
||
|
||
plcNodeAdaptsInputCarrier2 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the second carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 4 }
|
||
|
||
plcNodeAdaptsInputCarrier3 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the third carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 5 }
|
||
|
||
plcNodeAdaptsInputCarrier4 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the fourth carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 6 }
|
||
|
||
plcNodeAdaptsInputCarrier5 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the fifth carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 7 }
|
||
|
||
plcNodeAdaptsInputCarrier6 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the sixth carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 8 }
|
||
|
||
plcNodeAdaptsInputCarrier7 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the seventh carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 9 }
|
||
|
||
plcNodeAdaptsInputCarrier8 OBJECT-TYPE
|
||
SYNTAX AdaptValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The adapt level of the eighth carrier of the
|
||
considered group of the chosen band."
|
||
::= { plcNodeAdaptsInput 10 }
|
||
|
||
plcNodeAdaptsInputProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request a modification of the carrier
|
||
adapt level associated to the considered group and
|
||
band."
|
||
::= { plcNodeAdaptsInput 11 }
|
||
|
||
plcNodeAdaptsInputResult OBJECT-TYPE
|
||
SYNTAX ResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested node adapt level
|
||
value changes."
|
||
::= { plcNodeAdaptsInput 12 }
|
||
|
||
plcNodeNetConfigTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PlcNodeNetConfigEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains ip and mac
|
||
addresses of the node."
|
||
::= { plcNodeConfiguration 10 }
|
||
|
||
plcNodeNetConfigEntry OBJECT-TYPE
|
||
SYNTAX PlcNodeNetConfigEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains ip and mac address
|
||
used by an interface."
|
||
INDEX { ifIndex }
|
||
::= { plcNodeNetConfigTable 1 }
|
||
|
||
PlcNodeNetConfigEntry ::= SEQUENCE {
|
||
plcNodeIpAddr IpAddress,
|
||
plcNodeNetMask IpAddress,
|
||
plcNodeMacAddr MacAddress,
|
||
plcNodeGateway IpAddress
|
||
}
|
||
|
||
|
||
plcNodeIpAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The IP address of the IP layer above the interface."
|
||
::= { plcNodeNetConfigEntry 1 }
|
||
|
||
|
||
plcNodeNetMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The IP Subnet mask of the IP layer above the interface."
|
||
::= { plcNodeNetConfigEntry 2 }
|
||
|
||
|
||
plcNodeMacAddr OBJECT-TYPE
|
||
SYNTAX MacAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The MAC address of the MAC layer above the interface."
|
||
::= { plcNodeNetConfigEntry 3 }
|
||
|
||
plcNodeGateway OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The Gateway address of the IP layer above the interface."
|
||
::= { plcNodeNetConfigEntry 4 }
|
||
|
||
plcNodeActions OBJECT IDENTIFIER
|
||
::= { plcNodeConfiguration 11 }
|
||
|
||
plcNodeActionsCommit OBJECT IDENTIFIER
|
||
::= { plcNodeActions 1 }
|
||
|
||
plcNodeActionsCommitProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request the commit of the configuration
|
||
changes into the flash memory"
|
||
::= { plcNodeActionsCommit 1 }
|
||
|
||
plcNodeActionsCommitResult OBJECT-TYPE
|
||
SYNTAX ResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested flash commit operation."
|
||
::= { plcNodeActionsCommit 2 }
|
||
|
||
plcNodeActionsReset OBJECT IDENTIFIER
|
||
::= { plcNodeActions 2 }
|
||
|
||
plcNodeActionsResetProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request the reset of the node.
|
||
This operation will terminate the communication
|
||
between the manager and the node"
|
||
::= { plcNodeActionsReset 1 }
|
||
|
||
plcNodeActionsCarrier OBJECT IDENTIFIER
|
||
::= { plcNodeActions 3 }
|
||
|
||
plcNodeActionsCarrierFlatProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request the equipment to flat the signal"
|
||
::= { plcNodeActionsCarrier 1 }
|
||
|
||
|
||
plcBssId OBJECT IDENTIFIER
|
||
::= { plcObjects 6 }
|
||
|
||
plcMasterBssId OBJECT-TYPE
|
||
SYNTAX INTEGER(0..99)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The value of the master Bss Id"
|
||
::= { plcBssId 1 }
|
||
|
||
plcSlaveBssId OBJECT-TYPE
|
||
SYNTAX INTEGER(0..99)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The value of the slave Bss Id"
|
||
::= { plcBssId 2 }
|
||
|
||
plcSpy OBJECT IDENTIFIER
|
||
::= { plcObjects 7 }
|
||
|
||
plcSpyIsDynamic OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to set the spy dynamic mode"
|
||
::= { plcSpy 1 }
|
||
|
||
plcStaticSpySynchBandNb OBJECT-TYPE
|
||
SYNTAX BandValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The synchronization band number used for static spy mode"
|
||
::= { plcSpy 2 }
|
||
|
||
|
||
-- software upload
|
||
softwareMgnt OBJECT IDENTIFIER
|
||
::= { plc 3 }
|
||
|
||
-- current version
|
||
currentSoftwareVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The name of the current software release."
|
||
::= { softwareMgnt 1 }
|
||
|
||
currentSoftwareBoardVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The name of the current software board release."
|
||
::= { softwareMgnt 2 }
|
||
|
||
currentSoftwareAFEVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The name of the current software Analog Front End release."
|
||
::= { softwareMgnt 3 }
|
||
|
||
-- table of software
|
||
softwareTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SoftwareEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This table contains the current and reserve
|
||
softwares of the node."
|
||
::= { softwareMgnt 4 }
|
||
|
||
softwareEntry OBJECT-TYPE
|
||
SYNTAX SoftwareEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "This row contains software information."
|
||
INDEX { softwareIndex }
|
||
::= { softwareTable 1 }
|
||
|
||
SoftwareEntry ::= SEQUENCE {
|
||
softwareIndex SoftwareIndex,
|
||
softwareVersion DisplayString
|
||
}
|
||
|
||
softwareIndex OBJECT-TYPE
|
||
SYNTAX SoftwareIndex
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The index number of the software."
|
||
::= { softwareEntry 1 }
|
||
|
||
softwareVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The name of the software release."
|
||
::= { softwareEntry 2 }
|
||
|
||
-- upload software action
|
||
softwareUpload OBJECT IDENTIFIER
|
||
::= { softwareMgnt 5 }
|
||
|
||
softwareUploadTFTPServerIP OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The IP address of the TFTP serveur"
|
||
::= { softwareUpload 1 }
|
||
|
||
|
||
softwareUploadLogin OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The user login on the TFTP server"
|
||
::= { softwareUpload 2 }
|
||
|
||
softwareUploadPassword OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The user password on the TFTP server.
|
||
Warning: This field is displayed using 6 * characters"
|
||
::= { softwareUpload 3 }
|
||
|
||
softwareUploadFileName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The software file name to upload"
|
||
::= { softwareUpload 4 }
|
||
|
||
softwareUploadProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request the uploading to start"
|
||
::= { softwareUpload 5 }
|
||
|
||
softwareUploadResult OBJECT-TYPE
|
||
SYNTAX SoftwareActionResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested uploading"
|
||
::= { softwareUpload 6 }
|
||
|
||
softwareUploadTFTPServerPort OBJECT-TYPE -- PR01
|
||
SYNTAX Integer32 ( 0..65535 )
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The service port of the TFTP server"
|
||
::= { softwareUpload 7 }
|
||
|
||
|
||
-- software action
|
||
softwareAction OBJECT IDENTIFIER
|
||
::= { softwareMgnt 6 }
|
||
|
||
softwareActionIndex OBJECT-TYPE
|
||
SYNTAX SoftwareIndex
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The index of the reserve software"
|
||
::= { softwareAction 1 }
|
||
|
||
softwareActionType OBJECT-TYPE
|
||
SYNTAX SoftwareActionType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Type of the software action software:
|
||
switch, remove "
|
||
::= { softwareAction 2 }
|
||
|
||
softwareActionProceed OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True to request the switch between the current
|
||
and the reserver software to start"
|
||
::= { softwareAction 3 }
|
||
|
||
softwareActionResult OBJECT-TYPE
|
||
SYNTAX SoftwareActionResultValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Result value of the requested action"
|
||
::= { softwareAction 4 }
|
||
|
||
|
||
-- compliance
|
||
plcConformance OBJECT IDENTIFIER
|
||
::= { plc 4 }
|
||
|
||
plcCompliances OBJECT IDENTIFIER
|
||
::= { plcConformance 1 }
|
||
|
||
plcGroups OBJECT IDENTIFIER
|
||
::= { plcConformance 2 }
|
||
|
||
plcCompliance MODULE-COMPLIANCE
|
||
STATUS current
|
||
DESCRIPTION "The compliance statement for SPC200 chip."
|
||
|
||
MODULE
|
||
MANDATORY-GROUPS { nodeGroup, topologyGroup }
|
||
GROUP statisticGroup
|
||
DESCRIPTION "This group is mandatory for
|
||
channel performances analysis"
|
||
::= { plcCompliances 1 }
|
||
|
||
nodeGroup OBJECT-GROUP
|
||
OBJECTS { plcNodeNotches, plcMode,
|
||
plcNodeNotchesCarrier1, plcNodeNotchesCarrier2,
|
||
plcNodeNotchesCarrier3, plcNodeNotchesCarrier4,
|
||
plcNodeNotchesCarrier5, plcNodeNotchesCarrier6,
|
||
plcNodeNotchesCarrier7, plcNodeNotchesCarrier8,
|
||
plcNodePilots, plcNodePilot1, plcNodePilot2,
|
||
plcNodeAdaptsStringBand, plcNodeAdaptsCarrier1,
|
||
plcNodeAdaptsCarrier2, plcNodeAdaptsCarrier3,
|
||
plcNodeAdaptsCarrier4, plcNodeAdaptsCarrier5,
|
||
plcNodeAdaptsCarrier6, plcNodeAdaptsCarrier7,
|
||
plcNodeAdaptsCarrier8,
|
||
plcNodeIpAddr, plcNodeNetMask, plcNodeMacAddr,
|
||
plcNodeGateway, plcMasterBssId, plcSlaveBssId,
|
||
plcSpyIsDynamic, plcStaticSpySynchBandNb }
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects providing
|
||
node configuration information."
|
||
::= { plcGroups 1 }
|
||
|
||
inputNodeGroup OBJECT-GROUP
|
||
OBJECTS { plcNodeNotchesInputBand, plcNodeNotchesInputGroup,
|
||
plcNodeNotchesInputCarrier1, plcNodeNotchesInputCarrier2,
|
||
plcNodeNotchesInputCarrier3, plcNodeNotchesInputCarrier4,
|
||
plcNodeNotchesInputCarrier5, plcNodeNotchesInputCarrier6,
|
||
plcNodeNotchesInputCarrier7, plcNodeNotchesInputCarrier8,
|
||
plcNodeNotchesInputProceed, plcNodeNotchesInputResult,
|
||
plcNodePilotsInputBand,
|
||
plcInputNodePilot1, plcInputNodePilot2,
|
||
plcNodePilotsInputProceed,plcNodePilotsInputResult,
|
||
plcNodeAdaptsInputBand, plcNodeAdaptsInputGroup,
|
||
plcNodeAdaptsInputCarrier1, plcNodeAdaptsInputCarrier2,
|
||
plcNodeAdaptsInputCarrier3, plcNodeAdaptsInputCarrier4,
|
||
plcNodeAdaptsInputCarrier5, plcNodeAdaptsInputCarrier6,
|
||
plcNodeAdaptsInputCarrier7, plcNodeAdaptsInputCarrier8,
|
||
plcNodeAdaptsInputProceed, plcNodeAdaptsInputResult,
|
||
plcNodeActionsCommitProceed, plcNodeActionsCommitResult,
|
||
plcNodeActionsResetProceed, plcNodeActionsCarrierFlatProceed}
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects used to request
|
||
node configuration information changes."
|
||
::= { plcGroups 2 }
|
||
|
||
topologyGroup OBJECT-GROUP
|
||
OBJECTS { plcBasePortAddress, plcBasePortChannelEstimation,
|
||
plcBasePortAttenuation ,
|
||
plcChannePilot2, plcChannelPilot1,
|
||
plcRxChannelPilots,
|
||
plcRxLastChannelPilots,
|
||
plcTxChannelPilots,
|
||
plcRxChannelModulation,
|
||
plcRxLastChannelModulation,
|
||
plcTxChannelModulation,
|
||
plcModGroup1, plcModGroup10, plcModGroup11,
|
||
plcModGroup12, plcModGroup13, plcModGroup14,
|
||
plcModGroup15, plcModGroup16, plcModGroup2,
|
||
plcModGroup3, plcModGroup4, plcModGroup5,
|
||
plcModGroup6, plcModGroup7, plcModGroup8,
|
||
plcModGroup9,
|
||
plcPortChannelGain,
|
||
plcPortChannelBandwidth,
|
||
plcPortChannelMaxBandwidth,
|
||
plcPortChannelSynchronizationBand,
|
||
plcPortChannelType, plcTopoChanges }
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects providing
|
||
topology configuration."
|
||
::= { plcGroups 3 }
|
||
|
||
inputTopologyGroup OBJECT-GROUP
|
||
OBJECTS { plcModulationInputAddr, plcModulationInputChannel, plcModulationInputBand,
|
||
plcInputModulationGroup1, plcInputModulationGroup2,
|
||
plcInputModulationGroup3, plcInputModulationGroup4,
|
||
plcInputModulationGroup5, plcInputModulationGroup6,
|
||
plcInputModulationGroup7, plcInputModulationGroup8,
|
||
plcInputModulationGroup9, plcInputModulationGroup10,
|
||
plcInputModulationGroup11, plcInputModulationGroup12,
|
||
plcInputModulationGroup13, plcInputModulationGroup14,
|
||
plcInputModulationGroup15, plcInputModulationGroup16,
|
||
plcModulationInputProceed, plcModulationInputResult,
|
||
plcPilotsInputAddr, plcPilotsInputChannel, plcPilotsInputBand,
|
||
plcInputChannelPilot1, plcInputChannelPilot2,
|
||
plcPilotsInputProceed, plcPilotsInputResult }
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects used to request
|
||
topology configuration changes."
|
||
::= { plcGroups 4 }
|
||
|
||
statisticGroup OBJECT-GROUP
|
||
OBJECTS { --PR01 BEGIN
|
||
-- ipBridgedPackets, ipInBridgedPkts,
|
||
-- ipInErrorPackets, ipInErrorPkts, ipInPackets,
|
||
-- ipInPkts, ipOutErrorPackets, ipOutErrorPkts,
|
||
-- ipOutPackets, ipOutPkts, macInErrorPkts,
|
||
-- macInPkts, macOutErrorPkts, macOutPackets,
|
||
-- plcpInErrorPkts, plcpInPkts, plcpOutErrorPkts,
|
||
-- plcpOutPkts,
|
||
--PR01 END
|
||
portStats2AvgBandAtt, portStats2AvgBandSNR, --PR01
|
||
-- portStats2Ber,
|
||
portStats2Noise, portStats2Signal,
|
||
-- portStatsBer,
|
||
portStatsNoise, portStatsSignal,
|
||
portStats3AvgAtt, portStats3AvgSNR ,
|
||
bootstatsBoot, bootstatsManualReset, bootstatsFailureReset
|
||
} --PR01
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects providing
|
||
statistic data on node and plc link performances."
|
||
::= { plcGroups 5 }
|
||
|
||
softwareGroup OBJECT-GROUP
|
||
OBJECTS { currentSoftwareVersion, currentSoftwareBoardVersion,
|
||
currentSoftwareAFEVersion, softwareVersion,
|
||
softwareUploadTFTPServerIP, softwareUploadLogin,
|
||
softwareUploadPassword, softwareUploadFileName,
|
||
softwareUploadProceed, softwareUploadResult,
|
||
softwareUploadTFTPServerPort, --PR01
|
||
softwareActionIndex, softwareActionType,
|
||
softwareActionProceed, softwareActionResult }
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects providing
|
||
software management"
|
||
::= { plcGroups 6 }
|
||
|
||
--PR01 BEGIN
|
||
analyserGroup OBJECT-GROUP
|
||
OBJECTS { plcSNAnalyserAGC, plcSNAnalyserEnable,
|
||
plcSNAnalyserMinSignal, plcSNAnalyserMaxSignal,
|
||
plcSNAnalyserAvgSignal, plcSNAnalyserLastSignal,
|
||
plcSNAnalyserFFTDiv,
|
||
plcAGCAnalyserEnable,
|
||
plcAGCAnalyserSamplesPart1, plcAGCAnalyserSamplesPart2 }
|
||
STATUS current
|
||
DESCRIPTION "A collection of objects providing
|
||
spectrum analyser data"
|
||
::= { plcGroups 7 }
|
||
--PR01 END
|
||
|
||
agentCapabilities AGENT-CAPABILITIES
|
||
PRODUCT-RELEASE "Product-Release"
|
||
STATUS current
|
||
DESCRIPTION "The SPC200 chip SNMP agent capabilities"
|
||
|
||
SUPPORTS SPC200
|
||
INCLUDES { nodeGroup, inputNodeGroup,
|
||
topologyGroup, inputTopologyGroup,
|
||
statisticGroup, softwareGroup,
|
||
analyserGroup } --PR01
|
||
|
||
--OK SUPPORTS IF-MIB
|
||
--OK INCLUDES { ifGeneralInformationGroup, ifHCPacketGroup }
|
||
--OK VARIATION ifAdminStatus
|
||
--OK ACCESS read-only
|
||
--OK DESCRIPTION "Forbid the update of the administrative status"
|
||
--OK VARIATION ifLinkUpDownTrapEnable
|
||
--OK ACCESS not-implemented
|
||
--OK DESCRIPTION "No trap supported"
|
||
--KO VARIATION ifAlias
|
||
--KO ACCESS not-implemented
|
||
--KO DESCRIPTION "The non volatile alias name
|
||
--KO cannot be saved on the SPC200 chip"
|
||
--KO VARIATION ifMtu
|
||
--KO ACCESS not-implemented
|
||
--KO DESCRIPTION "Information not available on SPC200 chip"
|
||
|
||
SUPPORTS MAU-MIB
|
||
INCLUDES { mauIfGrpBasic }
|
||
VARIATION ifMauIndex
|
||
DESCRIPTION "Only one MAU. So the value is always 1"
|
||
VARIATION ifMauMediaAvailable
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ifMauMediaAvailableStateExits
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ifMauJabberState
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ifMauJabberingStateEnters
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
|
||
SUPPORTS IP-MIB
|
||
INCLUDES { ipGroup }
|
||
VARIATION ipForwarding
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipDefaultTTL
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipInHdrErrors
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipInAddrErrors
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipForwDatagrams
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipInUnknownProtos
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipInDiscards
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipInDelivers
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipOutDiscards
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipOutNoRoutes
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipReasmTimeout
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipReasmReqds
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipReasmOKs
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipReasmFails
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipFragOKs
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipFragFails
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipFragCreates
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipAdEntBcastAddr
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipAdEntReasmMaxSize
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
VARIATION ipRoutingDiscards
|
||
ACCESS not-implemented
|
||
DESCRIPTION "Information not available on SPC200 chip"
|
||
|
||
SUPPORTS SNMPv2-MIB
|
||
INCLUDES { systemGroup }
|
||
|
||
--OK SUPPORTS BRIDGE-MIB
|
||
--OK INCLUDES { dot1dBase }
|
||
--KO VARIATION dot1dBasePortDelayExceededDiscards
|
||
--KO ACCESS not-implemented
|
||
--KO DESCRIPTION "Information not available on SPC200 chip"
|
||
--KO VARIATION dot1dBasePortMtuExceededDiscards
|
||
--KO ACCESS not-implemented
|
||
--KO DESCRIPTION "Information not available on SPC200 chip"
|
||
|
||
::= { plcConformance 3 }
|
||
|
||
|
||
-- ifTableExt data
|
||
|
||
--ifTableExt OBJECT-TYPE
|
||
-- SYNTAX SEQUENCE OF IfEntryExt
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION
|
||
-- "A list of interface entries. The number of entries is
|
||
-- given by the value of ifNumber. This Table is an Ext of the
|
||
-- standard ifTable located in the IF-MIB."
|
||
-- ::= { spc200MIB 2 }
|
||
|
||
|
||
--ifEntryExt OBJECT-TYPE
|
||
-- SYNTAX IfEntryExt
|
||
-- MAX-ACCESS not-accessible
|
||
-- STATUS current
|
||
-- DESCRIPTION
|
||
-- "An entry containing management information applicable to a
|
||
-- particular interface. These entries are indexed using the ifIndex
|
||
-- of the standard IF-MIB."
|
||
-- INDEX { ifIndex }
|
||
-- ::= { ifTableExt 1 }
|
||
|
||
|
||
--IfEntryExt ::= SEQUENCE {
|
||
-- ifDefaultSpeed Gauge32,
|
||
-- ifSpeedAutoNegAdminStatus INTEGER }
|
||
|
||
|
||
--ifDefaultSpeed OBJECT-TYPE
|
||
-- SYNTAX Gauge32
|
||
-- MAX-ACCESS read-write
|
||
-- STATUS current
|
||
-- DESCRIPTION
|
||
-- "This field is used to set the speed for a given interface.
|
||
-- It contains a default value which will be copied into ifSpeed if
|
||
-- the ifSpeedAutoNegAdminStatus is disabled"
|
||
-- ::= { ifEntryExt 1 }
|
||
|
||
|
||
--ifSpeedAutoNegAdminStatus OBJECT-TYPE
|
||
-- SYNTAX INTEGER {
|
||
-- enabled(1),
|
||
-- disabled(2) }
|
||
-- MAX-ACCESS read-write
|
||
-- STATUS current
|
||
-- DESCRIPTION
|
||
-- "This field is used to enable/disable the speed auto negotiation
|
||
-- process for a given interface. If the status is disabled, the user
|
||
-- can set the speed by setting ifDefaultSpeed.
|
||
-- When the speed auto negotiation status is enabled, the hardware
|
||
-- select a speed and set it in ifSpeed. When the speed auto negotiation
|
||
-- status is disabled, the content of ifDefaultSpeed is copied into
|
||
-- ifSpeed."
|
||
-- ::= { ifEntryExt 2 }
|
||
|
||
|
||
--ifGroupExt OBJECT-GROUP
|
||
-- OBJECTS {
|
||
-- ifDefaultSpeed,
|
||
-- ifSpeedAutoNegAdminStatus }
|
||
-- STATUS current
|
||
-- DESCRIPTION
|
||
-- "The fields needed by the SPiDCOM functionalities"
|
||
|
||
-- ::= { ifTableExt 2 }
|
||
|
||
|
||
-- ipExt data , for DHCP mode
|
||
|
||
ipExt OBJECT-IDENTITY
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Extended ip needed for SPiDCOM functionalities"
|
||
::= { spc200MIB 4 }
|
||
|
||
ipDynamic OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "True if Ip address is set dynamically"
|
||
::= { ipExt 1 }
|
||
|
||
ipExtGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
ipDynamic
|
||
}
|
||
STATUS current
|
||
DESCRIPTION "The fields needed by the SPiDCOM functionalities"
|
||
::= { ipExt 2 }
|
||
|
||
END
|