mibs/MIBS/cisco/CERENT-454-MIB
2023-12-05 12:25:34 +01:00

24420 lines
707 KiB
Plaintext

-- **************************************************************
-- Cerent-454-MIB module
--
-- This module contains the objects and events for the
-- Cisco ONS 15454
-- Copyright (c) 1998-1999 by Cerent Corporation, Inc.
-- Copyright (c) 2000-2002, 2004-2005 by Cisco Systems, Inc.
-- All rights reserved.
--
-- **************************************************************
CERENT-454-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
OBJECT-IDENTITY,
NOTIFICATION-TYPE,
Integer32,
Unsigned32,
Counter32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString,
TruthValue,
TimeStamp
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
cerentProducts,
cerentModules
FROM CERENT-GLOBAL-REGISTRY
CerentNotificationClass,
CerentAlarmSeverity,
CerentAlarmStatus,
CerentAlarmServiceAffecting,
CerentMonitorType,
CerentLocation,
CerentPeriod,
CerentPortNumber
FROM CERENT-TC;
cerent454MibModule MODULE-IDENTITY
LAST-UPDATED "0410010000Z" -- 2004/Oct/01
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
" support@Cisco.com
Postal: Cisco Systems
1450 N. McDowell Blvd.
Petaluma, CA 94954
USA
Tel: +1-877-323-7368"
DESCRIPTION
"This module provides the definitions for
objects for managing Cisco OTBU ONS 15454."
REVISION "0410010000Z" -- 2004/Oct/01
DESCRIPTION
"This file can be used with R5.0 release."
::= { cerentModules 20 }
cerent454Mib OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The is the node under which all Cisco ONS 15454
specific mib object are located."
::= { cerentProducts 10 }
cerent454Conformance OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This node is created compliance. Has
objects as required by the RFCs"
::= { cerent454Mib 10 }
-- ********************************************************
cerentCommonObjects OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The objects here are expected to be
used by all Cisco OTBU Products.
These will be mixed with specific
objects of the product-specific branch."
::= { cerent454Mib 100 }
--
cerentCommonEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This branch is similar to cerentCommonObjects,
except that this will have only events"
::= { cerent454Mib 200 }
-- ********************************************************
cerent454Groups OBJECT-IDENTITY
STATUS current
DESCRIPTION
""
::= { cerent454Conformance 10 }
cerent454Compliance OBJECT-IDENTITY
STATUS current
DESCRIPTION
""
::= { cerent454Conformance 20 }
-- **************************************************************
-- Cisco ONS 15454 specific textual conventions
-- **************************************************************
Cerent454AlarmType ::= TEXTUAL-CONVENTION
-- DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"This TC is used by the NMS to map the alarm type
received by the trap and and display the string
shown in LHS."
SYNTAX INTEGER {
alarmUnknown ( 1 ),
alarmCutoffIsInManualMode ( 10 ),
failureDetectedExternalToTheNE ( 20 ),
externalError ( 30 ),
excessiveSwitching ( 40 ),
sdccTerminationFailure ( 50 ),
incomingFailureCondition ( 60 ),
alarmIndicationSignal ( 70 ),
alarmIndicationSignalLine ( 80 ),
alarmIndicationSignalPath ( 90 ),
alarmIndicationSignalVT ( 100 ),
apsChannelFailure ( 110 ),
channelByteFailureAPS ( 120 ),
channelProtectionSwitchingChannelMatchFailureAPS ( 130 ),
channelAutomaticProtectionSwitchModeMismatchAPS ( 140 ),
farEndProtectionLineFailure ( 150 ),
inconsistentAPSCode ( 160 ),
improperAPSCode ( 170 ),
nodeIdMismatch ( 180 ),
channelDefaultKAPS ( 190 ),
connectionLoss ( 200 ),
bipolarViolation ( 210 ),
carrierLossOnTheLAN ( 220 ),
concatenationErrorSTS ( 230 ),
excessCollisionsOnTheLAN ( 240 ),
facilityFailure ( 250 ),
farEndAIS ( 260 ),
farEndMultipleDS1LOSDetectedOnDS3 ( 270 ),
farEndDS1EqptFailNonServiceAffecting ( 280 ),
farEndDS1EqptFailServiceAffecting ( 290 ),
farEndSingleDS1LOS ( 300 ),
farEndDS3EqptFailNonServiceAffecting ( 310 ),
farEndDS3EqptFailServiceAffecting ( 320 ),
farEndCommonEquipmentFailureNonServiceAffecting ( 330 ),
farEndIDLE ( 340 ),
farEndLOS ( 350 ),
farEndLOF ( 360 ),
farEndBlockError ( 370 ),
ds3IdleCondition ( 380 ),
lossOfFrame ( 390 ),
lossOfPointer ( 400 ),
lossOfPointerPath ( 410 ),
lossOfPointerVT ( 420 ),
lossOfSignal ( 430 ),
outOfFrame ( 440 ),
pathSelectorFailure ( 450 ),
remoteAlarmIndication ( 460 ),
remoteFailureIndication ( 470 ),
remoteFailureIndicationLine ( 480 ),
remoteFailureIndicationPath ( 490 ),
remoteFailureIndicationVT ( 500 ),
signalDegrade ( 510 ),
severelyErroredFrame ( 520 ),
signalFailure ( 530 ),
signalLabelMismatchFailure ( 540 ),
payloadDefectIndication ( 550 ),
payloadDefectIndicationPath ( 560 ),
payloadLabelMismatchPath ( 570 ),
signalLabelMismatchFailurePayloadLabelMismatchVT ( 580 ),
unequippedPath ( 590 ),
signalLabelMismatchFailureUnequippedVT ( 600 ),
lossOfSynchronization ( 610 ),
outOfSynchronization ( 620 ),
primarySynchronizationReferenceFailure ( 630 ),
secondarySynchronizationReferenceFailure ( 640 ),
thirdSynchronizationReferenceFailure ( 650 ),
fourthSynchronizationReferenceFailure ( 660 ),
fifthSynchronizationReferenceFailure ( 670 ),
sixthSynchronizationReferenceFailure ( 680 ),
failedToReceiveSynchronizationStatusMessage ( 690 ),
synchronizationStatusMessagesAreDisabledOnThisInterface ( 700 ),
stratum1PrimaryReferenceSourceTraceable ( 710 ),
synchronizedTraceabilityUnknown ( 720 ),
stratum2Traceable ( 730 ),
transitNodeClockTraceable ( 740 ),
stratum3ETraceable ( 750 ),
stratum3Traceable ( 760 ),
sonetMinimumClockTraceable ( 770 ),
stratum4Traceable ( 780 ),
doNotUseForSynchronization ( 790 ),
reservedForNetworkSynchronizationUse ( 800 ),
outgoingFailureCondition ( 810 ),
remoteDefectIndicationLine ( 820 ),
remoteDefectIndicationPath ( 830 ),
freeRunningSynchronizationMode ( 840 ),
holdoverSynchronizationMode ( 850 ),
fastStartSynchronizationMode ( 860 ),
internalFault ( 870 ),
internalError ( 880 ),
internalMessageError ( 890 ),
mismatchOfEquipmentAndAttributes ( 900 ),
watchdogTimerTimeout ( 910 ),
softwareFaultOrFailure ( 920 ),
softwareFaultDataIntegrityFault ( 930 ),
programFailure ( 940 ),
controlEquipmentFailure ( 950 ),
primaryNonVolatileBackupMemoryFailure ( 960 ),
secondaryNonVolatileBackupMemoryFailure ( 970 ),
controlBusFailure ( 980 ),
controlBus1Failure ( 990 ),
controlBus2Failure ( 1000 ),
tccAToShelfSlot1DROP1CommunicationFailure ( 1010 ),
tccAToShelfSlot2DROP2CommunicationFailure ( 1020 ),
tccAToShelfSlot3DROP3CommunicationFailure ( 1030 ),
tccAToShelfSlot4DROP4CommunicationFailure ( 1040 ),
tccAToShelfSlot5TRUNK1CommunicationFailure ( 1050 ),
tccAToShelfSlot6TRUNK2CommunicationFailure ( 1060 ),
tccAToShelfSlot7TCCACommunicationFailure ( 1070 ),
tccAToShelfSlot8XCONACommunicationFailure ( 1080 ),
tccAToShelfSlot9AICCommunicationFailure ( 1090 ),
tccAToShelfSlot10XCONBCommunicationFailure ( 1100 ),
tccAToShelfSlot11TCCBCommunicationFailure ( 1110 ),
tccAToShelfSlot12TRUNK3CommunicationFailure ( 1120 ),
tccAToShelfSlot13TRUNK4CommunicationFailure ( 1130 ),
tccAToShelfSlot14DROP5CommunicationFailure ( 1140 ),
tccAToShelfSlot15DROP6CommunicationFailure ( 1150 ),
tccAToShelfSlot16DROP7CommunicationFailure ( 1160 ),
tccAToShelfSlot17DROP8CommunicationFailure ( 1170 ),
tccAToDCCAProcessorCommunicationFailure ( 1180 ),
tccBToShelfSlot1DROP1CommunicationFailure ( 1190 ),
tccBToShelfSlot2DROP2CommunicationFailure ( 1200 ),
tccBToShelfSlot3DROP3CommunicationFailure ( 1210 ),
tccBToShelfSlot4DROP4CommunicationFailure ( 1220 ),
tccBToShelfSlot5TRUNK1CommunicationFailure ( 1230 ),
tccBToShelfSlot6TRUNK2CommunicationFailure ( 1240 ),
tccBToShelfSlot7TCCACommunicationFailure ( 1250 ),
tccBToShelfSlot8XCONACommunicationFailure ( 1260 ),
tccBToShelfSlot9AICCommunicationFailure ( 1270 ),
tccBToShelfSlot10XCONBCommunicationFailure ( 1280 ),
tccBToShelfSlot11TCCBCommunicationFailure ( 1290 ),
tccBToShelfSlot12TRUNK3CommunicationFailure ( 1300 ),
tccBToShelfSlot13TRUNK4CommunicationFailure ( 1310 ),
tccBToShelfSlot14DROP5CommunicationFailure ( 1320 ),
tccBToShelfSlot15DROP6CommunicationFailure ( 1330 ),
tccBToShelfSlot16DROP7CommunicationFailure ( 1340 ),
tccBToShelfSlot17DROP8CommunicationFailure ( 1350 ),
tccBToDCCBProcessorCommunicationFailure ( 1360 ),
controlEquipmentControlCommunicationsEquipmentFailure ( 1370 ),
controlProcessorFailure ( 1380 ),
workingMemoryFailure ( 1390 ),
interconnectionEquipmentFailure ( 1400 ),
payloadBusFailureToIOSlot1XCONSlot8 ( 1410 ),
payloadBusFailureToIOSlot2XCONSlot8 ( 1420 ),
payloadBusFailureToIOSlot3XCONSlot8 ( 1430 ),
payloadBusFailureToIOSlot4XCONSlot8 ( 1440 ),
payloadBusFailureToIOSlot5XCONSlot8 ( 1450 ),
payloadBusFailureToIOSlot6XCONSlot8 ( 1460 ),
payloadBusFailureToIOSlot12XCONSlot8 ( 1470 ),
payloadBusFailureToIOSlot13XCONSlot8 ( 1480 ),
payloadBusFailureToIOSlot14XCONSlot8 ( 1490 ),
payloadBusFailureToIOSlot15XCONSlot8 ( 1500 ),
payloadBusFailureToIOSlot16XCONSlot8 ( 1510 ),
payloadBusFailureToIOSlot17XCONSlot8 ( 1520 ),
payloadBusFailureToIOSlot1XCONSlot10 ( 1530 ),
payloadBusFailureToIOSlot2XCONSlot10 ( 1540 ),
payloadBusFailureToIOSlot3XCONSlot10 ( 1550 ),
payloadBusFailureToIOSlot4XCONSlot10 ( 1560 ),
payloadBusFailureToIOSlot5XCONSlot10 ( 1570 ),
payloadBusFailureToIOSlot6XCONSlot10 ( 1580 ),
payloadBusFailureToIOSlot12XCONSlot10 ( 1590 ),
payloadBusFailureToIOSlot13XCONSlot10 ( 1600 ),
payloadBusFailureToIOSlot14XCONSlot10 ( 1610 ),
payloadBusFailureToIOSlot15XCONSlot10 ( 1620 ),
payloadBusFailureToIOSlot16XCONSlot10 ( 1630 ),
payloadBusFailureToIOSlot17XCONSlot10 ( 1640 ),
timeSlotInterchangeEquipmentFailure ( 1650 ),
equipmentFailure ( 1660 ),
highTemperature ( 1670 ),
invalidMACAddress ( 1680 ),
boardFailure ( 1690 ),
diagnosticFailure ( 1700 ),
mediumAccessControlFailure ( 1710 ),
facilityTerminationEquipmentFailure ( 1720 ),
automaticLaserShutoffDueToHighTemperature ( 1730 ),
failureToReleaseFromProtection ( 1740 ),
receiverFailure ( 1750 ),
transmitFailure ( 1760 ),
facilityTerminationEquipmentReceiverMissing ( 1770 ),
facilityTerminationEquipmentTransmitterMissing ( 1780 ),
failureToSwitchToProtection ( 1790 ),
failureToSwitchToProtectionRing ( 1800 ),
failureToSwitchToProtectionSpan ( 1810 ),
failureToSwitchToProtectionPath ( 1820 ),
fanFailure ( 1830 ),
equipmentUnitPlugIn ( 1840 ),
nePowerFailureAtConnector ( 1850 ),
fuseAlarm ( 1860 ),
synchronizationUnitFailure ( 1870 ),
synchronizationSwitchingEquipmentFailure ( 1880 ),
equipmentUnitUnplugged ( 1890 ),
loopback ( 1900 ),
ds1LoopbackDueToFEACCommand ( 1910 ),
loopbackCommandSentToFarEndDS1 ( 1920 ),
ds3LoopbackDueToFEACCommand ( 1930 ),
ds3LoopbackCommandSentToFarEnd ( 1940 ),
ds2LoopbackDueToFarEndCommand ( 1950 ),
ds2LoopbackCommandSentToFarEnd ( 1960 ),
facilityLoopback ( 1970 ),
networkLoopback ( 1980 ),
terminalLoopback ( 1990 ),
manuallyCausedAbnormalCondition ( 2000 ),
ethernetBridgeIsNewRootOfSpanningTree ( 2010 ),
ethernetBridgeTopologyChange ( 2020 ),
normalCondition ( 2030 ),
embeddedOperationsChannelFailureLinkDown ( 2040 ),
peerStateMismatch ( 2050 ),
proceduralError ( 2060 ),
improperRemoval ( 2070 ),
duplicateNodeID ( 2080 ),
blsrOutOfSync ( 2090 ),
blsrMultiNodeTableUpdateCompleted ( 2100 ),
protectionUnitNotAvailable ( 2110 ),
performanceMonitorThresholdCrossingAlert ( 2120 ),
protectionSwitch ( 2130 ),
recoveryOrServiceProtectionActionHasBeenInitiated ( 2140 ),
automaticSystemReset ( 2150 ),
automaticUPSRSwitchCausedByAIS ( 2160 ),
automaticUPSRSwitchCausedByLOP ( 2170 ),
automaticUPSRSwitchCausedByUNEQ ( 2180 ),
automaticUPSRSwitchCausedByPDI ( 2190 ),
automaticUPSRSwitchCausedBySFBER ( 2200 ),
automaticUPSRSwitchCausedBySDBER ( 2210 ),
coldRestart ( 2220 ),
forcedSwitchBackToWorking ( 2230 ),
forcedSwitchBackToWorkingRing ( 2240 ),
forcedSwitchBackToWorkingSpan ( 2250 ),
forcedSwitchToProtection ( 2260 ),
forcedSwitchToProtectionRing ( 2270 ),
forcedSwitchToProtectionSpan ( 2280 ),
workingFacilityOrEquipmentForcedToSwitchToProtectionPath ( 2290 ),
initializationInitiated ( 2300 ),
lockoutOfProtection ( 2310 ),
lockoutOfProtectionRing ( 2320 ),
lockoutOfProtectionSpan ( 2330 ),
lockoutOfProtectionPath ( 2340 ),
lockoutOfWorking ( 2350 ),
lockoutOfWorkingRing ( 2360 ),
lockoutOfWorkingSpan ( 2370 ),
manualSystemReset ( 2380 ),
manualSwitchToInternalClock ( 2390 ),
manualSwitchToPrimaryReference ( 2400 ),
manualSwitchToSecondReference ( 2410 ),
manualSwitchToThirdReference ( 2420 ),
manualSwitchToFourthReference ( 2430 ),
manualSwitchToFifthReference ( 2440 ),
manualSwitchToSixthReference ( 2450 ),
manualSwitchBackToWorking ( 2460 ),
manualSwitchBackToWorkingRing ( 2470 ),
manualSwitchBackToWorkingSpan ( 2480 ),
manualSwitchToProtection ( 2490 ),
manualSwitchToProtectionRing ( 2500 ),
manualSwitchToProtectionSpan ( 2510 ),
manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath ( 2520 ),
powerfailRestart ( 2530 ),
ringIsSquelchingTraffic ( 2540 ),
softwareDownloadInProgress ( 2550 ),
switchToInternalClock ( 2560 ),
switchToPrimaryReference ( 2570 ),
switchToSecondReference ( 2580 ),
switchToThirdReference ( 2590 ),
switchToFourthReference ( 2600 ),
switchToFifthReference ( 2610 ),
switchToSixthReference ( 2620 ),
systemReboot ( 2630 ),
switchedBackToWorking ( 2640 ),
switchedToProtection ( 2650 ),
warmRestart ( 2660 ),
ringIsInWaitToRestoreState ( 2670 ),
manualSwitchRequest ( 2680 ),
forcedSwitchRequest ( 2690 ),
lockoutSwitchRequest ( 2700 ),
rmonHistoriesAndAlarmsResetReboot ( 2710 ),
rmonThresholdCrossingAlarm ( 2720 ),
alarmsSuppressedByUserCommand ( 2730 ),
alarmsSuppressedForMaintenance ( 2740 ),
switchingMatrixModuleFailure ( 2750 ),
lanConnectionPolarityReversed ( 2760 ),
autonomousPMReportMessageInhibited ( 2780 ),
ioSlotToXCONCommunicationFailure ( 2790 ),
-- Intentional gap
stsPathTraceIdentifierMismatch ( 2800 ),
nePowerFailureAtConnectorA ( 2810 ),
nePowerFailureAtConnectorB ( 2820 ),
freeMemoryOnCardVeryLow ( 2830 ),
freeMemoryOnCardNearZero ( 2840 ),
exerciseRequestOnRing ( 2850 ),
exerciseRequestOnSpan ( 2860 ),
squelchingPath ( 2870 ),
extraTrafficPreempted ( 2880 ),
farEndLockoutOfWorkingRing ( 2890 ),
farEndLockoutOfWorkingSpan ( 2900 ),
farEndLockoutOfProtectionRing ( 2910 ),
farEndLockoutOfProtectionAllSpans ( 2920 ),
farEndWorkingFacilityForcedToSwitchToProtectionRing ( 2930 ),
farEndWorkingFacilityForcedToSwitchToProtectionSpan ( 2940 ),
farEndManualSwitchOfWorkingFacilityToProtectionRing ( 2950 ),
farEndManualSwitchOfWorkingFacilityToProtectionSpan ( 2960 ),
farEndExercisingRing ( 2970 ),
farEndExercisingSpan ( 2980 ),
farEndBERThresholdPassedForSignalFailureRing ( 2990 ),
farEndBERThresholdPassedForSignalFailureSpan ( 3000 ),
farEndBERThresholdPassedForSignalDegradeRing ( 3010 ),
farEndBERThresholdPassedForSignalDegradeSpan ( 3020 ),
apsChannelFarEndProtectionLineSignalDegrade ( 3030 ),
ringSwitchIsActiveOnTheEastSide ( 3040 ),
ringSwitchIsActiveOnTheWestSide ( 3050 ),
spanSwitchIsActiveOnTheEastSide ( 3060 ),
spanSwitchIsActiveOnTheWestSide ( 3070 ),
uniDirectionalFullPassThroughIsActive ( 3080 ),
biDirectionalFullPassThroughIsActive ( 3090 ),
kBytesPassThroughIsActive ( 3100 ),
ringIsSegmented ( 3110 ),
ringTopologyIsUnderConstruction ( 3120 ),
lockoutOfProtectionAllSpans ( 3130 ),
farEndOfFiberIsProvisionedWithDifferentRingID ( 3140 ),
bothEndsOfFiberProvisionedAsEastOrBothAsWest ( 3150 ),
securityInvalidLoginUsernameSeeAuditTrail ( 3160 ),
autonomousMessagesInhibited ( 3170 ),
trafficStormOnLANLANTemporarilyDisabled ( 3180 ),
reptdbchgMessagesInhibited ( 3190 ),
securityUserIDHasExpired ( 3200 ),
partialFanFailure ( 3210 ),
forcedSwitchRequestOnRing ( 3220 ),
forcedSwitchRequestOnSpan ( 3230 ),
lockoutSwitchRequestOnRing ( 3240 ),
lockoutSwitchRequestOnSpan ( 3250 ),
manualSwitchRequestOnRing ( 3260 ),
manualSwitchRequestOnSpan ( 3270 ),
communicationFailurePeerToPeerSlotControlBusA ( 3280 ),
communicationFailurePeerToPeerSlotControlBusB ( 3290 ),
controllerAToShelfSlotCommunicationFailure ( 3300 ),
controllerBToShelfSlotCommunicationFailure ( 3310 ),
interconnectionEquipmentFailureWorkingPayloadBus ( 3320 ),
interconnectionEquipmentFailureProtectPayloadBus ( 3330 ),
inhibitSwitchToProtectRequestOnEquipment ( 3340 ),
inhibitSwitchToWorkingRequestOnEquipment ( 3350 ),
berThresholdExceededForSignalDegradeLine ( 3360 ),
berThresholdExceededForSignalDegradePath ( 3370 ),
berThresholdExceededForSignalFailureLine ( 3380 ),
berThresholdExceededForSignalFailurePath ( 3390 ),
exercisingRingSuccessfully ( 3400 ),
exercisingSpanSuccessfully ( 3410 ),
spanIsInWaitToRestoreState ( 3420 ),
exerciseRequestOnRingFailed ( 3430 ),
exerciseRequestOnSpanFailed ( 3440 ),
farEndLockoutOfProtectionSpan ( 3450 ),
manufacturingDataMemoryEEPROMFailure ( 3460 ),
replaceableEquipmentOrUnitIsMissing ( 3470 ),
softwareDownloadFailed ( 3480 ),
extraTrafficPCADropped ( 3490 ),
etherTxOversubscribed ( 3500 ),
etherRxOverSubscribed ( 3510 ),
etherTxExcessFlowCtrl ( 3520 ),
etherRxExcessFlowCtrl ( 3530 ),
transportLayerFailure ( 3540 ),
etherTxUnderrun ( 3550 ),
synchronizationReferenceFrequencyOutOfBounds ( 3560 ),
ntpOrSntpHostFailure ( 3570 ),
peerCardNotResponding ( 3580 ),
alarmsAndEventsSuppressedForThisObject ( 3590 ),
ds3FrameFormatMismatch ( 3600 ),
waitToRestore ( 3610 ),
extremeHighVoltBatteryA ( 3620 ),
extremeLowVoltBatteryA ( 3630 ),
extremeHighVoltBatteryB ( 3640 ),
extremeLowVoltBatteryB ( 3650 ),
iosConfigCopyFailed ( 3660 ),
iosConfigCopyInProgress ( 3670 ),
iosConfigCopySuccess ( 3680 ),
-- 3660 through 3700 reserverd for R3.3.x releases
signalingUnableToSetupCircuit ( 3710 ),
errorInStartupConfig ( 3712 ),
noStartupConfig ( 3714 ),
needToSaveRunningConfig ( 3716 ),
invalidAlarm ( 3718 ),
rsvpHelloFSMToNeighborDown ( 3720 ),
securityInvalidLoginUsername ( 3722 ),
databaseBackupFailed ( 3724 ),
databaseRestoreFailed ( 3726 ),
lmpHelloFSMToControlChannelDown ( 3730 ),
lmpNeighborDiscoveryHasFailed ( 3740 ),
unauthorizedIncomingSignalingRequest ( 3750 ),
auditLog80PercentFull ( 3760 ),
moduleCommunicationFailure ( 3762 ),
auditLog100PercentFullOldestRecordsWillBeLost ( 3764 ),
standbyDatabaseOutOfSync ( 3766 ),
redundantPowerCapabilityLost ( 3768 ),
forcedSwitchToPrimaryReference ( 3770 ),
forcedSwitchToSecondReference ( 3780 ),
forcedSwitchToThirdReference ( 3790 ),
forcedSwitchToInternalClock ( 3800 ),
industrialHighTemperature ( 3805 ),
timSectionTraceIdentifierMismatchFailure ( 4000 ),
aisMultiplexSectionAlarmIndicationSignal ( 4010 ),
rdiMultiplexSectionRemoteDefectOrAlarmIndication ( 4020 ),
timHighOrderTraceIdentifierMismatchFailure ( 4030 ),
aisAdministrationUnitAlarmIndicationSignal ( 4040 ),
lopAdministrationUnitLossOfPointer ( 4050 ),
slmfUnequippedHighOrderPathUnequipped ( 4060 ),
slmfPLMHighOrderPathLabelMismatch ( 4070 ),
rdiHighOrderRemoteDefectOrAlarmIndication ( 4080 ),
lopTributaryUnitLossOfPointer ( 4090 ),
aisTributaryUnitAlarmIndicationSignal ( 4100 ),
slmfUnequippedLowOrderPathUnequipped ( 4110 ),
slmfPLMLowOrderPathLabelMismatch ( 4120 ),
timLowOrderTraceIdentifierMismatchFailure ( 4130 ),
rfiLowOrderRemoteFailureOrAlarmIndication ( 4140 ),
g811PrimaryReferenceClockTraceable ( 4150 ),
g812TransitNodeClockTraceable ( 4160 ),
g812LocalNodeClockTraceable ( 4170 ),
g813SynchronousEquipmentTimingSourceTraceable ( 4180 ),
e1LoopbackDueToFEACCommand ( 4190 ),
e1LoopbackCommandSentToFarEnd ( 4200 ),
e3LoopbackDueToFEACCommand ( 4210 ),
farEndMultipleE1LOSDetectedOnE3 ( 4220 ),
farEndE1EqptFailNonServiceAffecting ( 4230 ),
farEndE1EqptFailServiceAffecting ( 4240 ),
farEndSingleE1LOS ( 4250 ),
farEndE3EqptFailServiceAffecting ( 4260 ),
e3LoopbackCommandSentToFarEnd ( 4270 ),
farEndE3EqptFailNonServiceAffecting ( 4280 ),
lowVoltBatteryA ( 4290 ),
highVoltBatteryA ( 4300 ),
lowVoltBatteryB ( 4310 ),
highVoltBatteryB ( 4320 ),
msspRingOutOfSync ( 4330 ),
msspMultiNodeTableUpdateCompleted ( 4340 ),
automaticSNCPSwitchCausedByAIS ( 4350 ),
automaticSNCPSwitchCausedByLOP ( 4360 ),
automaticSNCPSwitchCausedByUNEQ ( 4370 ),
automaticSNCPSwitchCausedByPDI ( 4380 ),
automaticSNCPSwitchCausedBySFBER ( 4390 ),
automaticSNCPSwitchCausedBySDBER ( 4400 ),
stmConcatenationError ( 4410 ),
e3IdleCondition ( 4420 ),
channelMSSPInconsistentAPSCode ( 4430 ),
channelMSSPImproperAPSCodeAPS ( 4440 ),
channelMSSPNodeIdMismatchAPS ( 4450 ),
channelMSSPDefaultKAPS ( 4460 ),
channelMSSPConnectionLossAPS ( 4470 ),
minimumClockTraceableSDH ( 4480 ),
lineIsInWaitToRestoreStateSDH ( 4490 ),
berThresholdExceededForSignalDegradeHighOrder ( 4500 ),
berThresholdExceededForSignalFailureHighOrder ( 4510 ),
berThresholdExceededForSignalDegradeLowOrder ( 4520 ),
berThresholdExceededForSignalFailureLowOrder ( 4530 ),
failureToSwitchToProtectionHighOrderPath ( 4540 ),
failureToSwitchToProtectionLowOrderPath ( 4550 ),
lofAdministrationUnitLossOfMultiFrame ( 4560 ),
sdhSpanIsInWaitToRestoreState ( 4570 ),
a8b10bOutOfSync ( 4755 ),
odukPMAlarmIndicationSignal ( 4760 ),
otukAlarmIndicationSignal ( 4765 ),
otukSMBackwardDefectIndication ( 4770 ),
fecUncorrectedWord ( 4780 ),
gccTerminationFailure ( 4785 ),
otukIncomingAlignmentError ( 4790 ),
odukLockedDefectPM ( 4795 ),
lossOfMultiFrame ( 4800 ),
odukOpenConnectionIndication ( 4805 ),
payloadTypeIdentifierMismatch ( 4810 ),
odukTrailTraceIdentifierMismatch ( 4815 ),
otukTrailTraceIdentifierMismatch ( 4820 ),
equipmentHighLaserBias ( 4825 ),
equipmentHighLaserTemp ( 4830 ),
equipmentHighLaserPeltier ( 4835 ),
facilityHighRxPower ( 4840 ),
equipmentHighTxPower ( 4845 ),
equipmentHighTransceiverVoltage ( 4850 ),
equipmentLowLaserBias ( 4855 ),
equipmentLowLaserTemp ( 4860 ),
equipmentLowLaserPeltier ( 4865 ),
facilityLowRxPower ( 4870 ),
equipmentLowTxPower ( 4875 ),
equipmentLowTransceiverVoltage ( 4880 ),
equipmentRxLocked ( 4885 ),
equipmentSquelched ( 4890 ),
equipmentTxLocked ( 4895 ),
otukSignalFailure ( 4900 ),
odukSignalFailure ( 4905 ),
otukSignalDegrade ( 4910 ),
odukSignalDegrade ( 4915 ),
pluggablePortMissing ( 4920 ),
pluggablePortRateMismatch ( 4925 ),
pluggablePortSecurityCodeMismatch ( 4930 ),
tciNotSelected ( 4935 ),
tci1ClockFailure ( 4940 ),
odukPMBackwardDefectIndication ( 4945 ),
odukTCM1BackwardDefectIndication ( 4950 ),
odukTCM2BackwardDefectIndication ( 4955 ),
equipmentHighRxTemperature ( 4960 ),
equipmentLowRxTemperature ( 4965 ),
tci2ClockFailure ( 4970 ),
equipmentWavelengthMismatch ( 4975 ),
dspCommunicationFailure ( 4980 ),
dspFailure ( 4985 ),
laserApproachingEndOfLife ( 5000 ),
crossconnectLoopback ( 5010 ),
adminLogoutOfUser ( 5020 ),
userLockedOut ( 5030 ),
adminLockoutOfUser ( 5040 ),
adminLockoutClear ( 5050 ),
invalidLoginUsername ( 5060 ),
securityInvalidLoginPassword ( 5070 ),
securityInvalidLoginLockedOut ( 5080 ),
securityInvalidLoginAlreadyLoggedOn ( 5090 ),
loginOfUser ( 5100 ),
automaticLogoutOfIdleUser ( 5110 ),
logoutOfUser ( 5120 ),
enhancedRemoteFailureIndicationPathServer ( 5200 ),
enhancedRemoteFailureIndicationPathConnectivity ( 5210 ),
enhancedRemoteFailureIndicationPathPayload ( 5220 ),
firewallHasBeenDisabled ( 5230 ),
securityIntrusionDetPwd ( 5240 ),
securityIntrusionDetUser ( 5250 ),
connectionEquipmentMismatch ( 5260 ),
disableInactiveUser ( 5270 ),
disableInactiveClear ( 5280 ),
batteryFailure ( 5290 ),
extremeHighVolt ( 5300 ),
extremeLowVolt ( 5310 ),
highVolt ( 5320 ),
lowVolt ( 5330 ),
suspendUser ( 5340 ),
suspendUserClear ( 5350 ),
lineDccTerminationFailure ( 5360 ),
multiplexSectionDccTerminationFailure ( 5370 ),
gigaBitEthernetOutOfSync ( 5380 ),
sequenceMismatch ( 5390 ),
lossOfAlignment ( 5400 ),
outOfUseByAdministrativeCommand ( 5410 ),
outOfUseTransportFailure ( 5420 ),
vcatGroupDown ( 5430 ),
vcatGroupDegraded ( 5440 ),
vcatGroupIncomplete ( 5450 ),
alarmIndicationSignalInTX ( 5460 ),
remoteAlarmIndicationInTX ( 5470 ),
kByteAPSChannelFailure ( 5480 ),
apsInvalidMode ( 5490 ),
ipAddressAlreadyInUseWithinTheSameDccArea ( 5500 ),
nodeNameInUseWithinTheSameDccArea ( 5510 ),
rearPanelEthernetLinkRemoved ( 5520 ),
manualSwitchToProtectResultedInNoTrafficSwitch ( 5530 ),
manualSwitchBackToWorkingResultedInNoTrafficSwitch ( 5540 ),
forcedSwitchToProtectResultedInNoTrafficSwitch ( 5550 ),
forcedSwitchBackToWorkingResultedInNoTrafficSwitch ( 5560 ),
duplicateSerialNumberDetectedOnAPluggableEntity ( 5570 ),
lossOfSignalForOpticalChannel ( 5600 ),
encapsulationMismatchPath ( 5610 ),
encapsulationMismatchVT ( 5620 ),
encapsulationMismatchHighOrderPath ( 5630 ),
encapsulationMismatchLowOrderPath ( 5640 ),
gfpUserPayloadMismatch ( 5650 ),
gfpFibreChannelDistanceExtensionMismatch ( 5660 ),
gfpFibreChannelDistanceExtensionBufferStarvation ( 5670 ),
gfpFibreChannelDistanceExtensionCreditStarvation ( 5680 ),
automaticWdmAnsFinished ( 5690 ),
gfpClientSignalFailDetected ( 5700 ),
gfpLossOfFrameDelineation ( 5710 ),
gfpExtensionHeaderMismatch ( 5730 ),
incomingOverheadSignalAbsent ( 5740 ),
opticalSafetyRemoteInterlockOn ( 5750 ),
automaticPowerControlCorrectionSkipped ( 5770 ),
apcCannotSetValueDueToRangeLimits ( 5780 ),
lcasVcgMemberTxSideInAddState ( 5790 ),
farEndManualSwitchBackToWorkingSpan ( 5800 ),
farEndForcedSwitchBackToWorkingSpan ( 5810 ),
universalTransponderModuleHardwareFailure ( 5820 ),
universalTransponderModuleCommunicationFailure ( 5830 ),
pluginModuleRangeSettingsMismatch ( 5840 ),
lcasVcgMemberTxSideInDnuState ( 5850 ),
lcasControlWordCrcCheckFailure ( 5860 ),
lcasVcgMemberRxSideInFailState ( 5870 ),
signalLossOnDataInterface ( 5880 ),
synchronizationLossOnDataInterface ( 5890 ),
portFAIL ( 5900 ),
unreachablePortTargetPower ( 5910 ),
portAddPowerDegradeLow ( 5920 ),
portAddPowerDegradeHigh ( 5930 ),
portAddPowerFailLow ( 5940 ),
portAddPowerFailHigh ( 5950 ),
automaticPowerControlTerminatedOnManualRequest ( 6000 ),
oduk1AlarmIndicationSignal ( 6010 ),
oduk2AlarmIndicationSignal ( 6020 ),
oduk3AlarmIndicationSignal ( 6030 ),
oduk4AlarmIndicationSignal ( 6040 ),
temperatureReadingMismatchBetweenSCCards ( 6050 ),
voltageReadingMismatchBetweenSCCards ( 6060 ),
alarmsSuppressedonOutOfGroupVcatMember ( 6070 ),
blsrSoftwareVersionMismatch ( 6080 ),
optimized1Plus1ApsPrimaryFacility ( 6090 ),
optimized1Plus1ApsPrimarySectionMismatch ( 6100 ),
optimized1Plus1ApsInvalidPrimarySection ( 6110 ),
compositeClockHighLineVoltage ( 6120 ),
berThresholdExceededForSignalDegradeVt ( 6130 ),
berThresholdExceededForSignalFailureVt ( 6140 ),
spanLengthOutOfRange ( 6150 ),
idleSignalCondition ( 6170 ),
idleSignalConditionInTx ( 6180 ),
vtPathTraceIdentifierMismatch ( 6190 ),
lossOfFrameInTX ( 6200 ),
provisioningMismatch ( 6210 ),
sectionTraceIdentifierMismatch ( 6220 ),
regeneratorSectionTraceIdentifierMismatch ( 6230 ),
switchingMatrixModuleFailureWorking ( 6240 ),
switchingMatrixModuleFailureProtect ( 6250 ),
slotCommunicationDisabled ( 6260 ),
sessionTimeLimitExpired ( 6270 ),
userPasswordChangeRequired ( 6280 ),
isisAdjacencyFailure ( 6290 ),
msspSoftwareVersionMismatch ( 6300 ),
remoteAuthenticationFailSeeAuditLog ( 6310 ),
ringIsSquelchingStsTraffic ( 6330 ),
ringIsSquelchingVtTraffic ( 6340 ),
archiveOfAuditLogFailed ( 6350 ),
rprWrapped ( 6360 ),
shelfCommunicationFailure ( 6370 ),
duplicatedShelfIdentifier ( 6380 ),
softwareMismatch ( 6390 ),
lmpFailure ( 6400 ),
opticalTerminationIncomplete ( 6410 ),
forwardDefectIndication ( 6420 ),
payloadMissingIndication ( 6430 ),
spanMeasurementCannotBePerformed ( 6440 ),
ringIsSquelchingHighOrderTraffic ( 6450 ),
ringIsSquelchingLowOrderTraffic ( 6460 ),
badPacketCountExceedsThreshold ( 6470 ),
linkLayerKeepAliveFailure ( 6480 ),
autonegotiationRemoteFailureIndication ( 6490 ),
trailSignalFail ( 6500 ),
ds1LoopbackCommandSentToFarEnd ( 6510 ),
multiplexSectionSignalDegraded ( 6520 ),
multiplexSectionExcessiveErrors ( 6530 ),
highOrderPathSignalDegraded ( 6540 ),
highOrderPathExcessiveErrors ( 6550 ),
lowOrderPathSignalDegraded ( 6560 ),
lowOrderPathExcessiveErrors ( 6570 ),
regeneratorSectionDccTerminationFailure ( 6580 ),
networkMemoryPoolLow ( 6590 ),
ospfRoutingTableOverflow ( 6600 ),
autoLaserShutdownDisabled ( 6610 ),
rprProtectionIsActive ( 6630 ),
maxRPRStationNumberExceeded ( 6640 ),
rprProtectionConfigurationMismatched ( 6650 ),
reservedBandwidthLinkRateExceededOnRinglet0 ( 6660 ),
reservedBandwidthLinkRateExceededOnRinglet1 ( 6670 ),
rprInterfaceInPassThroughMode ( 6680 ),
rprPeerNodeIsMissing ( 6690 ),
rprRiFailure ( 6700 ),
rprSignalFailure ( 6710 ),
rprSignalDegrade ( 6720 ),
interlinkFailure ( 6730 ),
apcWrongGain ( 6740 ),
rprSpanMismatch ( 6750 ),
efmRemoteFaultIndicationCriticalEvent ( 6760 ),
efmRemoteFaultIndicationDyingGasp ( 6770 ),
efmRemoteFaultIndicationLinkFault ( 6780 ),
efmLinkMonitoringErroredSymbolPeriodEvent ( 6790 ),
efmLinkMonitoringErroredFrameEvent ( 6800 ),
efmLinkMonitoringErroredFramePeriodEvent ( 6810 ),
efmLinkMonitoringErroredFrameSecondsSummary ( 6820 ),
efmRemoteLoopbackRequestFailed ( 6830 ),
fastAutomaticProtectionSwitching ( 6840 ),
fastAutomaticProtectionSwitchingConfigMismatch ( 6850 ),
lcasSinkGroupError ( 6860 ),
lcasVcgMemberRxSideInDnuState ( 6870 ),
fcDistanceExtFuncNotEstablished ( 6880 ),
nonCiscoPPMInserted ( 6890 ),
unqualifiedPPMInserted ( 6900 ),
ftaMismatch ( 6910 ),
cardPortsUnableToProvideProtection ( 6920 ),
lmpSignalDegrade ( 6930 ),
lmpSignalFailure ( 6940 ),
lmpUnallocatedDataLink ( 6950 ),
frontPortLinkLoss ( 6960 ),
bertEnbl ( 6970 ),
bertSyncFail ( 6975 ),
workQueueFull ( 6980 ),
equipmentPowerFailureAtConnectorA ( 7000 ),
equipmentPowerFailureAtConnectorB ( 7005 ),
equipmentPowerFailureAtReturnConnectorA ( 7010 ),
equipmentPowerFailureAtReturnConnectorB ( 7015 ),
bridgeAndRollHasOccurred ( 7055 ),
bridgeAndRollIsPendingAValidSignal ( 7060 ),
clockBusFailureTscA ( 7160 ),
clockBusFailureTscB ( 7165 ),
ospfHelloFail ( 7185 ),
openIOSlots ( 7200 ),
lossOfClockFromMateShelfController ( 7210 ),
virtualLanAlarmIndiacationSignal ( 7225 ),
dcuLossFailure ( 7230 ),
ochncMaintenance ( 7235 ),
ramanLaserShutdown ( 7240 ),
losOfRamanSignal ( 7245 ),
mcastMacTableFull ( 7250 ),
multicastMacAddressAliasing ( 7255 ),
ramanPwrProtOn ( 7260 ),
cppPeerNotResponding ( 7265 ),
voaControlLoopDisableDueToExcessiveCounterPropagationLight ( 7275 ),
wizardIsRunning ( 7280 ),
ramanGainNotReached ( 7285 ),
pprForwardDefectIndication ( 7295 ),
pprBackwardDefectIndication ( 7300 ),
pprCoordinatedMaintenance ( 7305 ),
pprTriggerThresholdBerExceeded ( 7310 ),
localFault ( 7315 ),
remoteFault ( 7320 ),
efmRemoteLoopbackConfigured ( 7325 ),
efmPeerMissing ( 7330 ),
eqptDegrade ( 7335 ),
excessiveBackPropagation ( 7340 ),
remoteMaintenanceEndPointIsDown ( 7345 ),
crossConnectedCFMService ( 7350 ),
cfmLoop ( 7355 ),
cfmConfigurationError ( 7360 ),
outOfChannelGroupBundle ( 7365 ),
repNeighborAdjacencyFailure ( 7370 ),
repLinkFlapping ( 7375 ),
faultInREPSegment ( 7380 ),
primaryREPEdgePortElected ( 7385 ),
secondaryREPEdgePortElected ( 7390 ),
stcnREPGenerated ( 7395 ),
vlbREPActivated ( 7400 ),
vlbREPTriggerSoakingDelayActive ( 7405 ),
wanSyncloss ( 7410 ),
laserShutdownDueToWavelengthDrift ( 7415 ),
manualLaserRestart ( 7420 ),
laserShutdownDueToNonCiscoPPMInserted ( 7425 ),
ethernetOSCTerminationFailure ( 7430 ),
softwareSignatureVerificationFailed ( 7445 ),
protectVolumeSoftwareSignatureVerificationFailed ( 7450 ),
activeVolumeSoftwareSignatureVerificationFailed ( 7455 ),
peerPortClientSignalFailDetected (7460),
channelShutdownDueToWavelengthDrift ( 7465 ),
usbWriteFailure ( 7475 ),
usbSyncInProgress ( 7480 ),
autoSensingUnableToDetectValidPayload (7485),
payloadAutoSensingInProgress (7490),
gfpClientSignalFailDetectedDueToSigloss (7495),
gfpClientSignalFailDetectedDueToSyncloss (7500),
pmdDegrade (7510),
standbyTccNEClockIsInternalClock ( 7515 ),
chromaticDispersionValue ( 7520 ),
packetTransportServiceFailed ( 7525 ),
satellitePanelDiscoveryFailure ( 7530 ),
satellitePanelActiveLinkFailure ( 7535 ),
satellitePanelCommunicationFailure ( 7540 ),
satellitePanelImproperConfiguration ( 7545 ),
satellitePanelFanMismatchOfEquipmentAndAttributes ( 7550 ),
satellitePanelFanFailure ( 7555 ),
satellitePanelPartialFanFailure ( 7560 ),
satellitePanelFANManufacturingDataMemoryEEPROMFailure ( 7565 ),
satellitePanelFANUnitIsMissing ( 7570 ),
satellitePanelIndustrialHighTemperature ( 7575 ),
satellitePanelHighTemperature ( 7580 ),
satellitePanelBatteryFailureA ( 7585 ),
plannedSwitchOver ( 7590 ),
protectionCardConfigurationMismatch ( 7595 ),
routerProcessorSwitchOver ( 7600 ),
runningLowOnResources ( 7605 ),
noMoreResourcesAreAvailable ( 7610 ),
esmcFailure ( 7615 ),
licenseWillExpireWithin24Hours ( 7620 ),
licenseWillExpireAnytimeAfter1DayButBefore14Days ( 7625 ),
licenseIsExpired ( 7630 ),
licenseCountViolation ( 7635 ),
temporaryLicenseIsInUse ( 7640 ),
evaluationLicenseIsInUse ( 7645 ),
licenseIsMissing ( 7650 ),
pseudowireDown ( 7655 ),
workingPseudowireControlPlaneDown ( 7660 ),
protectPseudowireControlPlaneDown ( 7665 ),
workingPseudowireConnectivityCheckDown ( 7670 ),
protectPseudowireConnectivityCheckDown ( 7675 ),
pseudowireTrafficSwitchedToProtection ( 7680 ),
workingPseudowireLocalAcTxPortFault ( 7685 ),
protectPseudowireLocalAcTxPortFault ( 7690 ),
workingPseudowireLocalAcRxPortFault ( 7695 ),
protectPseudowireLocalAcRxPortFault ( 7700 ),
workingPseudowireRemoteAcTxPortFault ( 7705 ),
protectPseudowireRemoteAcTxPortFault ( 7710 ),
workingPseudowireRemoteAcRxPortFault ( 7715 ),
protectPseudowireRemoteAcRxPortFault ( 7720 ),
slaThresholdCrossAlert ( 7725 ),
protectLocalPseudowireNotForwarding ( 7730 ),
workingPseudowireNotForwarding ( 7735 ),
protectPseudowireNotForwarding ( 7740 ),
tpTunnelDown ( 7745 ),
workingLabelSwitchedPathDown ( 7750 ),
protectLabelSwitchedPathDown ( 7755 ),
workingLabelSwitchedPathAlarmIndicationSignal ( 7760 ),
protectLabelSwitchedPathAlarmIndicationSignal ( 7765 ),
workingLabelSwitchedPathRemoteDefectIndication ( 7770 ),
protectLabelSwitchedPathRemoteDefectIndication ( 7775 ),
bidirectionalForwardDetectionDown ( 7780 ),
tpTrafficSwitchedFromWorkingToProtection ( 7785 ),
workingTpLockout ( 7790 ),
protectTpLockout ( 7795 ),
ethernetFlowPointFailed ( 7800 ),
teTunnelDown ( 7805 ),
macSystemLimitReached ( 7810 ),
macBridgeDomainLimitReached ( 7815 ),
autoSensingDisabled ( 7820 ),
smBackwardIncomingAlignmentError ( 7825 ),
resourceAllocationFailed ( 7830 ),
lossOfDFBSignal ( 7835 ),
workingLabelSwitchedPathLinkDownIndication ( 7840 ),
protectLabelSwitchedPathLinkDownIndication ( 7845 ),
workingLabelSwitchedPathLockReport ( 7850 ),
protectLabelSwitchedPathLockReport ( 7855 ),
satellitePanelBatteryFailureB ( 7860 ),
highBitErrorRate (7865),
backPanelFacilityLoopback (7870),
backPanelTerminalLoopback (7875),
trunkPayloadTypeMismatch (7880),
invalidMuxponderConfiguration (7885),
coolingProfileMismatch (7890),
trunkOduAlarmIndicationSignal (7895),
companionCardMissing (7900),
controlPlaneUnverifiedClearedAlarmsPresent (7905),
powerConsumptionLimitHasCrossed (7910),
masterKeyExchangeFailed (7915),
unitHighTemperature (7930),
overTemperatureUnitProtected (7935),
seqMismatchCount (7945),
keyProgramOnAlteraFpgaFailed (7960),
duplicateNodeControllerDetected (7970),
restorationInProg (7975),
ramanPumpsCalibrationProcedureIsRunning (7980),
ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes (7985),
odukTCM1AlarmIndicationSignal ( 13100 ),
odukTCM2AlarmIndicationSignal ( 13105 ),
odukLockedDefectTCM1 ( 13110 ),
odukLockedDefectTCM2 ( 13115 ),
otukLossOfFrame ( 13120 ),
odukOpenConnectionIndicationTCM1 ( 13125 ),
odukOpenConnectionIndicationTCM2 ( 13130 ),
odukTrailTraceIdentifierMismatchTCM1 ( 13135 ),
odukTrailTraceIdentifierMismatchTCM2 ( 13140 ),
odukSignalFailureTCM1 ( 13145 ),
odukSignalFailureTCM2 ( 13150 ),
odukSignalDegradeTCM1 ( 13155 ),
odukSignalDegradeTCM2 ( 13160 ),
lossOfChannel ( 13165 ),
fecMismatch ( 13170 ),
timSectionMonitorTraceIdentifierMismatchFailure ( 13175 ),
automaticLaserShutdown ( 13180 ),
shutterInsertionLossVariationDegradeLow ( 13200 ),
opticalChannelDeactivationFailure ( 13205 ),
shutterInsertionLossVariationDegradeHigh ( 13210 ),
networkTopologyIncomplete ( 13215 ),
pluginModuleCommunicationFailure ( 13220 ),
opticalNetworkTypeMismatch ( 13225 ),
opticalPowerDegradeLow ( 13230 ),
automaticPowerControlFailure ( 13235 ),
opticalPowerDegradeHigh ( 13240 ),
automaticPowerControlDisabled ( 13245 ),
opticalPowerFailureLow ( 13250 ),
ringIdMismatch ( 13255 ),
opticalPowerFailureHigh ( 13260 ),
lossOfContinuity ( 13270 ),
variableOpticalAttenuatorDegradeLow ( 13280 ),
variableOpticalAttenuatorDegradeHigh ( 13290 ),
variableOpticalAttenuatorFailureLow ( 13300 ),
variableOpticalAttenuatorFailureHigh ( 13310 ),
laserBiasDegrade ( 13320 ),
laserBiasFailure ( 13330 ),
laserTemperatureDegrade ( 13340 ),
opticalAmplifierGainDegradeLow ( 13350 ),
opticalAmplifierGainDegradeHigh ( 13360 ),
opticalAmplifierGainFailureLow ( 13370 ),
opticalAmplifierGainFailureHigh ( 13380 ),
opticalChannelConnectionFailure ( 13390 ),
opticalChannelIncomplete ( 13395 ),
opticalChannelActivationFailure ( 13400 ),
laserAutoPowerReduction ( 13410 ),
caseTemperatureDegrade ( 13420 ),
fiberTemperatureDegrade ( 13430 ),
shutterOpen ( 13440 ),
awgTemperatureDegrade ( 13450 ),
awgTemperatureFailure ( 13460 ),
awgOverTemperature ( 13470 ),
opticalAmplifierInitialization ( 13480 ),
awgWarmUp ( 13490 ),
incSigloss ( 13510 ),
incSyncloss ( 13515 ),
incGfpOutOfFrame ( 13520 ),
incGfpSigLoss ( 13525 ),
incGfpSyncLoss ( 13530 )
}
-- Cerent454ObjectType ::= TEXTUAL-CONVENTION
-- DISPLAY-HINT "d"
-- STATUS current
-- DESCRIPTION
-- "Very similar to the alarm type TC, except this is
-- used for object type display"
-- SYNTAX INTEGER {
-- objectNone ( 1 ),
-- objectEntity ( 10 ),
-- objectInterface ( 20 ),
-- objectOspf ( 30 ),
-- objectProtectionGroup ( 40 ),
-- objectSdccTerm ( 50 ),
-- objectSync ( 60 ),
-- objectSecurity ( 70 ),
-- objectTopologyElement ( 80 ),
-- objectSystem ( 90 ),
-- objectStsConnection ( 100 ),
-- objectVtConnection ( 110 ),
-- objectSonetPool ( 120 ),
-- objectEtherBridge ( 130 ),
-- objectSpanningTree ( 140 ),
-- objectVlan ( 150 ),
-- objectCircuit ( 160 )
-- }
Cerent454EntityClass ::= TEXTUAL-CONVENTION
-- DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"This is the TC used to find out to which cerent454EntityClass
an alarm belongs to."
SYNTAX INTEGER {
unknownEntity ( 1 ),
ne ( 10 ),
backplane ( 30 ),
eqpt ( 50 ),
port ( 60 ),
ocn ( 70 ),
stmn ( 71 ),
aip ( 80 ),
fanTray ( 90 ),
crs ( 100 ),
ds3 ( 110 ),
almExpPanel ( 120 ),
almIfExtnsn ( 130 ),
stsMon ( 140 ),
vcMonHp ( 141 ),
dwdmClient ( 150 ),
stsTerm ( 160 ),
vcTermHp ( 161 ),
dwdmTrunk ( 170 ),
dwdmOptics ( 180 ),
psSts ( 190 ),
rsms ( 200 ),
xcSts ( 210 ),
bits ( 220 ),
dwdmFec ( 230 ),
neSynchRef ( 240 ),
dwdm8b10b ( 250 ),
extSynchRef ( 260 ),
dwdmOtn ( 270 ),
envAlrm ( 280 ),
envCtrl ( 290 ),
neRing ( 360 ),
ds1 ( 390 ),
vtMon ( 410 ),
vcMonLp ( 411 ),
vtTerm ( 420 ),
vcTermLP ( 421 ),
fUdc ( 430 ),
msUdc ( 440 ),
spareSdcc ( 450 ),
ucpCircuit ( 480 ),
ucpIpcc ( 490 ),
ucpNeighbor ( 500 ),
ec1 ( 510 ),
ps ( 520 ),
psVt ( 530 ),
e100t ( 540 ),
e1000t ( 550 ),
etherBridge ( 560 ),
e1 ( 600 ),
e3 ( 630 ),
e4 ( 640 ),
stm1E ( 650 ),
ds3i ( 660 ),
g1000 ( 670 ),
ml100t ( 680 ),
ml1000 ( 690 ),
dwdmSfp ( 700 ),
dwdmScl ( 710 ),
dwdmTcm1 ( 720 ),
dwdmTcm2 ( 730 ),
dwdmOcn ( 740 ),
dwdmSm ( 750 ),
dwdmPm ( 760 ),
dwdmTcm ( 770 ),
pwr ( 780 ),
stsTermVcat ( 790 ),
vtTermVcat ( 800 ),
vcatGroup ( 810 ),
fcmr ( 820 ),
entOptics ( 830 ),
ce100t ( 840 ),
ppm ( 850 ),
twor ( 860 ),
isc ( 870 ),
escon ( 880 ),
bic ( 890 ),
gfp ( 900 ),
gige ( 910 ),
pos ( 920 ),
cap ( 930 ),
dwdmData ( 940 ),
logFac ( 950 ),
ge ( 960 ),
fc ( 970 ),
ec1p1 ( 980 ),
mlFx ( 990 ),
ochTerm ( 1000 ),
shelf ( 1010 ),
ce1000 ( 1020 ),
cemr ( 1030 ),
lmp ( 1040 ),
lmpControlChannel ( 1050 ),
lmpTeLink ( 1060 ),
lmpDataLink ( 1070 ),
rpr ( 1080 ),
ether ( 1090 ),
mlmr ( 1100 ),
otu ( 1110 ),
aots ( 3200 ),
ots ( 3210 ),
oms ( 3220 ),
och ( 3230 ),
osc ( 3240 ),
ochnc ( 3250 ),
ib ( 3260 ),
chgrp ( 3270 ),
hdlc ( 3280 ),
msISC ( 3290 ),
ecu ( 3300 ),
lcdFlash ( 3310 ),
usb ( 3320 ),
fe ( 3330 ),
odu0 ( 3350 ),
odu1 ( 3360 )
}
-- **************************************************************
cerent454Objects OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The cerent454 specific objects themselves"
::= { cerent454Mib 20 }
-- **************************************************************
-- All Cisco OTBU generic objects definitions
-- These will be available for all Cisco OTBU products. Hence
-- they are defined once under generic category.
cerent454CommonObjectsGroup OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The group to combine all the Cisco OTBU common
objects"
::= { cerentCommonObjects 10 }
cerent454EnableNotification OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates whether the system produces
notifications. A value=FALSE will prevent notifications
from being sent by this system."
DEFVAL { true }
::= { cerent454CommonObjectsGroup 10 }
cerent454NodeTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates current local time as reflected by
the Cisco OTBU equipment. The format this scalar is
YYYYMMDDhhmmss{S/D}. E.g.,
20011103133453D means 1:34:53 PM PDT on 03/Nov/2001
19990614095436S means 9:54:36 AM PST on 14/Jun/1999.
If the last octet is S then the time is standard time.
Otherwise it is D to indicate it is daylight saving
time, if applicable"
::= { cerent454CommonObjectsGroup 20 }
cerent454SentNotifications OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of v1+v2 notifications sent out
by the agent. Resets to zero after
cold/warm start."
::= { cerent454CommonObjectsGroup 30 }
cerent454LastChangeTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time
a conceptual row is created or deleted
in cerent454AlarmTable "
::= { cerent454CommonObjectsGroup 40 }
cerent454MultishelfEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates whether the system is configured
in multi-shelf mode or single-shelf mode."
DEFVAL { false }
::= { cerent454CommonObjectsGroup 50 }
-- **************************************************************
--
cerent454GeneralGroup OBJECT-IDENTITY
STATUS current
DESCRIPTION
""
::= { cerent454Objects 20 }
cerent454SoftwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the version of software that is
used in Cisco ONS 15454. E.g., 2.2.03"
::= { cerent454GeneralGroup 10 }
cerent454AlarmGroup OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The group that will represent all the
alarm info in the Cisco ONS 15454 node"
::= { cerent454Objects 30 }
cerent454AlarmCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of active alarms in Cisco ONS 15454.
This equals the total number of rows in
cerent454AlarmTable at any time."
::= { cerent454AlarmGroup 10 }
cerent454AlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cerent454AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table has all currently raised conditions
for the network node. A Condition is a fault or
status detected by hardware or software."
::= { cerent454AlarmGroup 20 }
cerent454AlarmEntry OBJECT-TYPE
SYNTAX Cerent454AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for cerent454AlarmTable"
INDEX { cerent454AlarmIndex, cerent454AlarmType }
::= { cerent454AlarmTable 1 }
Cerent454AlarmEntry ::= SEQUENCE {
cerent454AlarmIndex Integer32,
cerent454AlarmObjectType Cerent454EntityClass,
cerent454AlarmSlotNumber Integer32,
cerent454AlarmPortNumber CerentPortNumber,
cerent454AlarmLineNumber Integer32,
cerent454AlarmObjectIndex Integer32,
cerent454AlarmType Cerent454AlarmType,
cerent454AlarmState CerentNotificationClass,
cerent454AlarmTimeStamp TimeStamp,
cerent454AlarmObjectName DisplayString,
cerent454AlarmAdditionalInfo DisplayString,
cerent454AlarmSeverity CerentAlarmSeverity,
cerent454AlarmStatus CerentAlarmStatus,
cerent454AlarmServiceAffecting CerentAlarmServiceAffecting
}
cerent454AlarmIndex OBJECT-TYPE
SYNTAX Integer32 ( 1..2147483647 ) -- all +ve values
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies each entry in alarm table.
May not start with one and there may be some
missing numbers."
::= { cerent454AlarmEntry 10 }
cerent454AlarmObjectType OBJECT-TYPE
SYNTAX Cerent454EntityClass
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This will indicate what is the type
of the entity which raised this alarm.
( E.g., DS3, etherBridge, VT-TERM, etc )
The NMS is expected to use this value
to decide which table to poll for
further info about the alarm"
::= { cerent454AlarmEntry 20 }
cerent454AlarmSlotNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This will indicate what is the slot
of the object which raised this alarm.
If not relevant to the alarm, will be
zero."
::= { cerent454AlarmEntry 30 }
cerent454AlarmPortNumber OBJECT-TYPE
SYNTAX CerentPortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This will indicate what is the port
of the object which raised this alarm."
::= { cerent454AlarmEntry 40 }
cerent454AlarmLineNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This will indicate what is the port
of the object which raised this alarm.
If not relevant to the alarm, will be
zero."
::= { cerent454AlarmEntry 50 }
cerent454AlarmObjectIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Every alarm is raised by an object and
this object is an entry in a specific
table. This is the index of the object
in that table E.g., if the alarm is interface
related, this index is the index of the
interface in the interface table."
::= { cerent454AlarmEntry 60 }
cerent454AlarmType OBJECT-TYPE
SYNTAX Cerent454AlarmType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates what the exact nature of the
alarm. See the Cerent454AlarmType TC
for mapping details "
::= {cerent454AlarmEntry 70 }
cerent454AlarmState OBJECT-TYPE
SYNTAX CerentNotificationClass
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies alarm severity and service
affecting status ( SA/NSA ). Only
{minor|major|critical}+{NA|NSA} alarms and
standing conditions will be represented here.
However, this mib object is included in each
trap dispatched and in the trap this object
can contain all the possible values of
CerentNotificationClass type."
::= { cerent454AlarmEntry 80 }
cerent454AlarmTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this entry was
created. This is accurate only upto a second."
::= { cerent454AlarmEntry 90 }
cerent454AlarmObjectName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TL1-style user-visible name which uniquely
identifies an object in the system"
::= { cerent454AlarmEntry 100 }
cerent454AlarmAdditionalInfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Additional information for the alarm object.
In the current version of the MIB, this object
contains the following information :-
a) Provisioned description for alarms of type
'failureDetectedExternalToTheNE'.
This object would be a null string if no
additional information is specified."
::= { cerent454AlarmEntry 110 }
cerent454AlarmSeverity OBJECT-TYPE
SYNTAX CerentAlarmSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies severity of the alarm
being sent out."
::= { cerent454AlarmEntry 120 }
cerent454AlarmStatus OBJECT-TYPE
SYNTAX CerentAlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents if the alarm is currently raised
or cleared."
::= { cerent454AlarmEntry 130 }
cerent454AlarmServiceAffecting OBJECT-TYPE
SYNTAX CerentAlarmServiceAffecting
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether the alarm that is being
sent out is Service Affecting (SA) or Non-
Service Affecting (NSA)."
::= { cerent454AlarmEntry 140 }
cerent454ReportedAlarmCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of alarms currently reported against Cisco
ONS 15454. This equals the number of rows in
cerent454ReportedAlarmTable."
::= { cerent454AlarmGroup 30 }
cerent454ReportedAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cerent454ReportedAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table has the list of alarms currently
reported for the Cisco ONS node. It does not
include any cleared alarms. The alarms in this
table are in compliance with Telcordia GR-253.
This means that if a network problem causes two
alarms, such a as loss of frame(LOF) and loss of
signal(LOS), only LOS alarm will be in this table
because it supersedes and replaces the LOF."
::= { cerent454AlarmGroup 40 }
cerent454ReportedAlarmEntry OBJECT-TYPE
SYNTAX Cerent454ReportedAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for cerent454ReportedAlarmTable"
INDEX { cerent454ReportedAlarmIndex, cerent454ReportedAlarmType }
::= { cerent454ReportedAlarmTable 1 }
Cerent454ReportedAlarmEntry ::= SEQUENCE {
cerent454ReportedAlarmIndex Integer32,
cerent454ReportedAlarmObjectType Cerent454EntityClass,
cerent454ReportedAlarmSlotNumber Integer32,
cerent454ReportedAlarmPortNumber CerentPortNumber,
cerent454ReportedAlarmObjectIndex Integer32,
cerent454ReportedAlarmType Cerent454AlarmType,
cerent454ReportedAlarmTimeStamp TimeStamp,
cerent454ReportedAlarmObjectName DisplayString,
cerent454ReportedAlarmAdditionalInfo DisplayString,
cerent454ReportedAlarmSeverity CerentAlarmSeverity,
cerent454ReportedAlarmStatus CerentAlarmStatus,
cerent454ReportedAlarmServiceAffecting CerentAlarmServiceAffecting
}
cerent454ReportedAlarmIndex OBJECT-TYPE
SYNTAX Integer32 ( 1..2147483647 ) -- all +ve values
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies each entry in ReportedAlarm table.
May not start with one and there may be some
missing numbers."
::= { cerent454ReportedAlarmEntry 10 }
cerent454ReportedAlarmObjectType OBJECT-TYPE
SYNTAX Cerent454EntityClass
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This will indicate the type
of the entity which raised this alarm.
( E.g., DS3, etherBridge, VT-TERM, etc )
The NMS is expected to use this value
to decide which table to poll for
further info about the alarm"
::= { cerent454ReportedAlarmEntry 20 }
cerent454ReportedAlarmSlotNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This will indicate what is the slot
of the object which raised this alarm.
If not relevant to the alarm, will be
zero."
::= { cerent454ReportedAlarmEntry 30 }
cerent454ReportedAlarmPortNumber OBJECT-TYPE
SYNTAX CerentPortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This will indicate what is the port
of the object which raised this alarm."
::= { cerent454ReportedAlarmEntry 40 }
cerent454ReportedAlarmObjectIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Every alarm is raised by an object and
this object is an entry in a specific
table. This is the index of the object
in that table E.g., if the alarm is interface
related, this is the index of the
interface in the interface table."
::= { cerent454ReportedAlarmEntry 50 }
cerent454ReportedAlarmType OBJECT-TYPE
SYNTAX Cerent454AlarmType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the exact nature of the
alarm."
::= {cerent454ReportedAlarmEntry 60 }
cerent454ReportedAlarmTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this entry was
created. This is accurate only upto a second."
::= { cerent454ReportedAlarmEntry 70 }
cerent454ReportedAlarmObjectName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TL1-style user-visible name which uniquely
identifies an object in the system"
::= { cerent454ReportedAlarmEntry 80 }
cerent454ReportedAlarmAdditionalInfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Additional information for the alarm object.
In the current version of the MIB, this object
contains the following information :-
a) Provisioned description for alarms of type
'failureDetectedExternalToTheNE'.
This object would be a null string if no
additional information is specified."
::= { cerent454ReportedAlarmEntry 90 }
cerent454ReportedAlarmSeverity OBJECT-TYPE
SYNTAX CerentAlarmSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies severity of the alarm."
::= { cerent454ReportedAlarmEntry 100 }
cerent454ReportedAlarmStatus OBJECT-TYPE
SYNTAX CerentAlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents if the alarm is currently raised
or cleared."
::= { cerent454ReportedAlarmEntry 110 }
cerent454ReportedAlarmServiceAffecting OBJECT-TYPE
SYNTAX CerentAlarmServiceAffecting
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether the alarm that is being
sent out is Service Affecting (SA) or Non-
Service Affecting (NSA)."
::= { cerent454ReportedAlarmEntry 120 }
-- All Cisco ONS 15454 Threshold definitions.
cerent454ThresholdGroup OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The group that will represent all the
threshold info in the Cisco ONS 15454 node"
::= { cerent454Objects 40 }
cerent454ThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cerent454ThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table holds all the defined
Thresholds.
This table is currently unimplemented."
::= { cerent454ThresholdGroup 10 }
cerent454ThresholdEntry OBJECT-TYPE
SYNTAX Cerent454ThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for cerent454ThresholdTable"
INDEX { cerent454ThresholdIndex }
::= { cerent454ThresholdTable 1 }
Cerent454ThresholdEntry ::= SEQUENCE {
cerent454ThresholdIndex Integer32,
cerent454ThresholdMonitorType CerentMonitorType,
cerent454ThresholdLocation CerentLocation,
cerent454ThresholdPeriod CerentPeriod,
cerent454ThresholdSetValue Integer32,
cerent454ThresholdCurrentValue Integer32,
cerent454ThresholdDetectType INTEGER
}
cerent454ThresholdIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647) -- Same as IfIndex from IF-MIB
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies each entry in Threshold table.
May not start with one and there will be some
missing numbers."
::= { cerent454ThresholdEntry 10 }
cerent454ThresholdMonitorType OBJECT-TYPE
SYNTAX CerentMonitorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the type of metric monitored."
::= { cerent454ThresholdEntry 20 }
cerent454ThresholdLocation OBJECT-TYPE
SYNTAX CerentLocation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates if it near or far end"
::= { cerent454ThresholdEntry 30 }
cerent454ThresholdPeriod OBJECT-TYPE
SYNTAX CerentPeriod
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sampling interval period is indicated here"
::= { cerent454ThresholdEntry 40 }
cerent454ThresholdSetValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object will be threshold that was
provisioned by the NMS"
::= { cerent454ThresholdEntry 50 }
-- TEXTUAL CONVENTION
-- Description
-- The value of the optical parameter that is being monitored.
--
-- The range of values varies depending on the type of optical
-- parameter being monitored, as identified by a corresponding
-- object with syntax OpticalParameterType.
--
-- when the optical parameter being monitored is 'power' or
-- 'acpower', the supported range is from -1000 to 1000, in
-- 1/10ths of dBm.
-- Example: Actual power of -40 dbm is represented as -400.
-- Actual power level of +30 dBm is represented as 300.
--
-- When the optical parameter being monitored is 'laserTemp' or
-- 'apdTemp', the supported range is from -10000 to 30000, in
-- 1/100ths of degrees centigrade.
-- Example: A value of 2355 represents a temperature reading of
-- 23.55 degrees C.
--
-- When the optical parameter being monitored is 'biasCurrent',
-- the supported range is from 0 to 1000, in 1/10ths of
-- percentage (%).
-- Example: A value of 500 represents a bias current threshold
-- of 50.0 %.
--
-- When the optical parameter being monitored is 'peltierCurrent',
-- the supported range is from 0 to 10000, in milliamperes.
--
-- When the optical parameter being monitored is 'xcvrVoltage',
-- the supported range is from 0 to 100000, in 1/10ths of
-- millivolts.
cerent454ThresholdCurrentValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current value of the counter which
measures the metric. This column will never be
implemented as the value of this object is already
accessible through IETF MIBs."
::= { cerent454ThresholdEntry 60 }
-- TEXTUAL CONVENTION
-- Description
-- The value of the optical parameter that is being monitored.
--
-- The range of values varies depending on the type of optical
-- parameter being monitored, as identified by a corresponding
-- object with syntax OpticalParameterType.
--
-- when the optical parameter being monitored is 'power' or
-- 'acpower', the supported range is from -1000 to 1000, in
-- 1/10ths of dBm.
-- Example: Actual power of -40 dbm is represented as -400.
-- Actual power level of +30 dBm is represented as 300.
--
-- When the optical parameter being monitored is 'laserTemp' or
-- 'apdTemp', the supported range is from -10000 to 30000, in
-- 1/100ths of degrees centigrade.
-- Example: A value of 2355 represents a temperature reading of
-- 23.55 degrees C.
--
-- When the optical parameter being monitored is 'biasCurrent',
-- the supported range is from 0 to 1000, in 1/10ths of
-- percentage (%).
-- Example: A value of 500 represents a bias current threshold
-- of 50.0 %.
--
-- When the optical parameter being monitored is 'peltierCurrent',
-- the supported range is from 0 to 10000, in milliamperes.
--
-- When the optical parameter being monitored is 'xcvrVoltage',
-- the supported range is from 0 to 100000, in 1/10ths of
-- millivolts.
cerent454ThresholdDetectType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
none(10),
mon(20),
term(30)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object will be the detect type for the
threshold."
::= { cerent454ThresholdEntry 70 }
-- All Cisco ONS 15454 Notifications definitions.
cerent454Events OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Place holder for all notifications of Cisco ONS 15454"
::= { cerent454Mib 30 }
cerent454V2Events OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The sub-identifier has to be zero, as part
of the interoperability agreement between
SNMPv1 and SNMPv2 worlds."
::= { cerent454Events 0 }
-- ---------------------------------------------
-- All the Cisco ONS 15454 notifications definitions
-- ---------------------------------------------
-- object and event groups
alarmUnknown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "alarm unknown"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1 }
alarmCutoffIsInManualMode
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "alarm cutoff is in manual mode"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 10 }
failureDetectedExternalToTheNE
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmAdditionalInfo,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "failure detected External to the NE"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 20 }
externalError
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "external error"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 30 }
excessiveSwitching
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "excessive switching"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 40 }
sdccTerminationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "SDCC Termination failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 50 }
incomingFailureCondition
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "incoming failure condition"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 60 }
alarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "alarm indication signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 70 }
alarmIndicationSignalLine
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "alarm indication signal LINE"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 80 }
alarmIndicationSignalPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "alarm indication signal Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 90 }
alarmIndicationSignalVT
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "alarm indication signal VT"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 100 }
apsChannelFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"APS Channel Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 110 }
channelByteFailureAPS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "channel Byte failure APS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 120 }
channelProtectionSwitchingChannelMatchFailureAPS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "channel Protection Switching Channel Match failure APS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 130 }
channelAutomaticProtectionSwitchModeMismatchAPS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "channel Automatic Protection Switch Mode Mismatch APS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 140 }
farEndProtectionLineFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Far End Protection Line Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 150 }
inconsistentAPSCode
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Inconsistent APS code"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 160 }
improperAPSCode
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Improper APS code"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 170 }
nodeIdMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Node Id Mismatch APS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 180 }
channelDefaultKAPS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "channel Default K APS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 190 }
connectionLoss
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Connection loss APS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 200 }
bipolarViolation
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "bipolar Violation"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 210 }
carrierLossOnTheLAN
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "carrier Loss on the LAN"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 220 }
concatenationErrorSTS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "concatenation error STS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 230 }
excessCollisionsOnTheLAN
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "excess collisions on the LAN"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 240 }
facilityFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Facility Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 250 }
farEndAIS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end AIS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 260 }
farEndMultipleDS1LOSDetectedOnDS3
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end Multiple DS1 LOS detected on DS3"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 270 }
farEndDS1EqptFailNonServiceAffecting
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end DS1 eqpt fail non service affecting"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 280 }
farEndDS1EqptFailServiceAffecting
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end DS1 Eqpt fail service affecting"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 290 }
farEndSingleDS1LOS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end Single DS1 LOS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 300 }
farEndDS3EqptFailNonServiceAffecting
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end DS3 Eqpt failure non service affecting"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 310 }
farEndDS3EqptFailServiceAffecting
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end DS3 Eqpt failure service affecting"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 320 }
farEndCommonEquipmentFailureNonServiceAffecting
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end common Eqpt failure non service affecting"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 330 }
farEndIDLE
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end IDLE"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 340 }
farEndLOS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end LOS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 350 }
farEndLOF
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end LOF"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 360 }
farEndBlockError
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far End Block Error"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 370 }
ds3IdleCondition
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "idle Condition DS3"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 380 }
lossOfFrame
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "loss of Frame"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 390 }
lossOfPointer
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "loss of Pointer"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 400 }
lossOfPointerPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "loss of Pointer Path "
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 410 }
lossOfPointerVT
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "loss of Pointer VT"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 420 }
lossOfSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "loss of Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 430 }
outOfFrame
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "out of Frame"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 440 }
pathSelectorFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Path Selector Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 450 }
remoteAlarmIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "remote Alarm Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 460 }
remoteFailureIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "remote Failure Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 470 }
remoteFailureIndicationLine
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "remote Failure Indication LINE"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 480 }
remoteFailureIndicationPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "remote Failure Indication Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 490 }
remoteFailureIndicationVT
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "remote Failure Indication VT"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 500 }
signalDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "facility has passed BER Threshold for Signal Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 510 }
severelyErroredFrame
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "severely Errored Frame"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 520 }
signalFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "facility has passed BER threshold for Signal Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 530 }
signalLabelMismatchFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "signal Label Mismatch Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 540 }
payloadDefectIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Payload Defect Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 550 }
payloadDefectIndicationPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Payload Defect Indication - Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 560 }
payloadLabelMismatchPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Payload Label Mismatch - Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 570 }
signalLabelMismatchFailurePayloadLabelMismatchVT
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "signal Label Mismatch Failure Payload Label Mismatch VT"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 580 }
unequippedPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Unequipped - Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 590 }
signalLabelMismatchFailureUnequippedVT
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "signal Label Mismatch Failure Unequipped VT"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 600 }
lossOfSynchronization
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Loss of Synchronization"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 610 }
outOfSynchronization
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Out of Synchronization"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 620 }
primarySynchronizationReferenceFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Primary Synchronization Reference Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 630 }
secondarySynchronizationReferenceFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Secondary Synchronization Reference Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 640 }
thirdSynchronizationReferenceFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Third Synchronization Reference Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 650 }
fourthSynchronizationReferenceFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Fourth Synchronization Reference Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 660 }
fifthSynchronizationReferenceFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Fifth Synchronization Reference Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 670 }
sixthSynchronizationReferenceFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Sixth Synchronization Reference Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 680 }
failedToReceiveSynchronizationStatusMessage
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "failed to receive Synchronization Status Message"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 690 }
synchronizationStatusMessagesAreDisabledOnThisInterface
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "synchronization Status Messages are disabled on this
interface"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 700 }
stratum1PrimaryReferenceSourceTraceable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Stratum1 Primary Reference Source Traceable"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 710 }
synchronizedTraceabilityUnknown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "synchronized Traceability Unknown"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 720 }
stratum2Traceable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "stratum 2 Traceable "
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 730 }
transitNodeClockTraceable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "transit Node clock Traceable"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 740 }
stratum3ETraceable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "stratum 3E Traceable"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 750 }
stratum3Traceable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "stratum 3 Traceable"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 760 }
sonetMinimumClockTraceable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "SONET Minimum Clock Traceable"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 770 }
stratum4Traceable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "stratum 4 Traceable"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 780 }
doNotUseForSynchronization
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "do not Use for Synchronization"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 790 }
reservedForNetworkSynchronizationUse
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "reserved for Network Synchronization Use"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 800 }
outgoingFailureCondition
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "outgoing failure condition"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 810 }
remoteDefectIndicationLine
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "remote Defect Indication LINE"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 820 }
remoteDefectIndicationPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "remote Defect Indication Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 830 }
freeRunningSynchronizationMode
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "free Running Synchronization mode"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 840 }
holdoverSynchronizationMode
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "holdover synchronization mode"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 850 }
fastStartSynchronizationMode
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "fast Start synchronization mode"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 860 }
internalFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Internal Fault"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 870 }
internalError
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Internal Error"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 880 }
internalMessageError
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "internal Message Error"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 890 }
mismatchOfEquipmentAndAttributes
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "mismatch of Equipment and Attributes"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 900 }
watchdogTimerTimeout
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "watchdog Timer Timeout"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 910 }
softwareFaultOrFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "software Fault or failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 920 }
softwareFaultDataIntegrityFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "software Fault - Data integrity fault :
The newly added provisioning or hardware has
caused the database to grow beyond its limit.
That is, the newly added object(s) in the system
has(have) enough memory to exist onboard but
too large to be saved in the database."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 930 }
programFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "program failure "
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 940 }
controlEquipmentFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "control Equipment failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 950 }
primaryNonVolatileBackupMemoryFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Primary Non-Volatile Backup Memory Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 960 }
secondaryNonVolatileBackupMemoryFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Secondary Non-Volatile Backup Memory Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 970 }
controlBusFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Control Bus Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 980 }
controlBus1Failure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Control Bus 1 Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 990 }
controlBus2Failure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Control Bus 2 Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1000 }
tccAToShelfSlot1DROP1CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 1 (DROP 1) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1010 }
tccAToShelfSlot2DROP2CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 2 (DROP 2) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1020 }
tccAToShelfSlot3DROP3CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 3 (DROP 3) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1030 }
tccAToShelfSlot4DROP4CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 4 (DROP 4) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1040 }
tccAToShelfSlot5TRUNK1CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 5 (TRUNK 1) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1050 }
tccAToShelfSlot6TRUNK2CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 6 (TRUNK 2) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1060 }
tccAToShelfSlot7TCCACommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 7 (TCC A) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1070 }
tccAToShelfSlot8XCONACommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 8 (XCON A) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1080 }
tccAToShelfSlot9AICCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 9 (AIC) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1090 }
tccAToShelfSlot10XCONBCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 10 (XCON B) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1100 }
tccAToShelfSlot11TCCBCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 11 (TCC B) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1110 }
tccAToShelfSlot12TRUNK3CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 12 (TRUNK 3) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1120 }
tccAToShelfSlot13TRUNK4CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 13 (TRUNK 4) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1130 }
tccAToShelfSlot14DROP5CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 14 (DROP 5) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1140 }
tccAToShelfSlot15DROP6CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 15 (DROP 6) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1150 }
tccAToShelfSlot16DROP7CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 16 (DROP 7) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1160 }
tccAToShelfSlot17DROP8CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC A To Shelf Slot 17 (DROP 8) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1170 }
tccAToDCCAProcessorCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "communication failure TCC A to DCC A processor"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1180 }
tccBToShelfSlot1DROP1CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 1 (DROP 1) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1190 }
tccBToShelfSlot2DROP2CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 2 (DROP 2) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1200 }
tccBToShelfSlot3DROP3CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 3 (DROP 3) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1210 }
tccBToShelfSlot4DROP4CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 4 (DROP 4) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1220 }
tccBToShelfSlot5TRUNK1CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 5 (TRUNK 1) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1230 }
tccBToShelfSlot6TRUNK2CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 6 (TRUNK 2) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1240 }
tccBToShelfSlot7TCCACommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 7 (TCC A) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1250 }
tccBToShelfSlot8XCONACommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 8 (XCON A) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1260 }
tccBToShelfSlot9AICCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 9 (AIC) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1270 }
tccBToShelfSlot10XCONBCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 10 (XCON B) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1280 }
tccBToShelfSlot11TCCBCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 11 (TCC B) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1290 }
tccBToShelfSlot12TRUNK3CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 12 (TRUNK 3) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1300 }
tccBToShelfSlot13TRUNK4CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 13 (TRUNK 4) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1310 }
tccBToShelfSlot14DROP5CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 14 (DROP 5) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1320 }
tccBToShelfSlot15DROP6CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 15 (DROP 6) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1330 }
tccBToShelfSlot16DROP7CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 16 (DROP 7) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1340 }
tccBToShelfSlot17DROP8CommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To Shelf Slot 17 (DROP 8) Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1350 }
tccBToDCCBProcessorCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TCC B To DCC B Processor Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1360 }
controlEquipmentControlCommunicationsEquipmentFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "control Equipment Control Communications equipment failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1370 }
controlProcessorFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Control Processor Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1380 }
workingMemoryFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Working Memory Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1390 }
interconnectionEquipmentFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "interconnection Equipment failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1400 }
payloadBusFailureToIOSlot1XCONSlot8
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 1 (XCON Slot 8)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1410 }
payloadBusFailureToIOSlot2XCONSlot8
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 2 (XCON Slot 8)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1420 }
payloadBusFailureToIOSlot3XCONSlot8
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 3 (XCON Slot 8)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1430 }
payloadBusFailureToIOSlot4XCONSlot8
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 4 (XCON Slot 8)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1440 }
payloadBusFailureToIOSlot5XCONSlot8
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 5 (XCON Slot 8)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1450 }
payloadBusFailureToIOSlot6XCONSlot8
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 6 (XCON Slot 8)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1460 }
payloadBusFailureToIOSlot12XCONSlot8
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 12 (XCON Slot 8)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1470 }
payloadBusFailureToIOSlot13XCONSlot8
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 13 (XCON Slot 8)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1480 }
payloadBusFailureToIOSlot14XCONSlot8
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 14 (XCON Slot 8)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1490 }
payloadBusFailureToIOSlot15XCONSlot8
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 15 (XCON Slot 8)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1500 }
payloadBusFailureToIOSlot16XCONSlot8
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 16 (XCON Slot 8)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1510 }
payloadBusFailureToIOSlot17XCONSlot8
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 17 (XCON Slot 8)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1520 }
payloadBusFailureToIOSlot1XCONSlot10
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 1 (XCON Slot 10)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1530 }
payloadBusFailureToIOSlot2XCONSlot10
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 2 (XCON Slot 10)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1540 }
payloadBusFailureToIOSlot3XCONSlot10
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 3 (XCON Slot 10)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1550 }
payloadBusFailureToIOSlot4XCONSlot10
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 4 (XCON Slot 10)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1560 }
payloadBusFailureToIOSlot5XCONSlot10
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 5 (XCON Slot 10)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1570 }
payloadBusFailureToIOSlot6XCONSlot10
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 6 (XCON Slot 10)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1580 }
payloadBusFailureToIOSlot12XCONSlot10
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 12 (XCON Slot 10)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1590 }
payloadBusFailureToIOSlot13XCONSlot10
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 13 (XCON Slot 10)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1600 }
payloadBusFailureToIOSlot14XCONSlot10
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 14 (XCON Slot 10)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1610 }
payloadBusFailureToIOSlot15XCONSlot10
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 15 (XCON Slot 10)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1620 }
payloadBusFailureToIOSlot16XCONSlot10
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 16 (XCON Slot 10)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1630 }
payloadBusFailureToIOSlot17XCONSlot10
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Payload Bus Failure To IO Slot 17 (XCON Slot 10)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1640 }
timeSlotInterchangeEquipmentFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Time Slot Interchange Equipment Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1650 }
equipmentFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "equipment failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1660 }
highTemperature
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "High Temperature"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1670 }
invalidMACAddress
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Invalid MAC Address"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1680 }
boardFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Board Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1690 }
diagnosticFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "equipment failure Diagnostics Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1700 }
mediumAccessControlFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Medium Access Control Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1710 }
facilityTerminationEquipmentFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "facility Termination equipment failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1720 }
automaticLaserShutoffDueToHighTemperature
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Automatic Laser Shutoff Due To High Temperature"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1730 }
failureToReleaseFromProtection
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "failure To Release from protection"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1740 }
receiverFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Receiver Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1750 }
transmitFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Transmit Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1760 }
facilityTerminationEquipmentReceiverMissing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "facility Termination equipment Receiver missing"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1770 }
facilityTerminationEquipmentTransmitterMissing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "facility Termination equipment Transmitter missing"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1780 }
failureToSwitchToProtection
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "failure To Switch to protection"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1790 }
failureToSwitchToProtectionRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "failure To Switch to protection Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1800 }
failureToSwitchToProtectionSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "failure To Switch to protection Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1810 }
failureToSwitchToProtectionPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "failure to Switch to protection Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1820 }
fanFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Fan Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1830 }
equipmentUnitPlugIn
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "equipment unit plug in"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1840 }
nePowerFailureAtConnector
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "NE Power Failure At Connector"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1850 }
fuseAlarm
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Fuse Alarm"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1860 }
synchronizationUnitFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "synchronization unit failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1870 }
synchronizationSwitchingEquipmentFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "synchronization switching Equipment failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1880 }
equipmentUnitUnplugged
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Equipment Unit Un-plugged"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1890 }
loopback
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "loop back"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1900 }
ds1LoopbackDueToFEACCommand
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"DS1 Loopback Due To FEAC Command"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1910 }
loopbackCommandSentToFarEndDS1
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "loopback Command sent to Far End DS1"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1920 }
ds3LoopbackDueToFEACCommand
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "loopback due to FEAC command DS3"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1930 }
ds3LoopbackCommandSentToFarEnd
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"DS3 Loopback Command Sent To Far End"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1940 }
ds2LoopbackDueToFarEndCommand
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"DS2 Loopback Due To Far End Command"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1950 }
ds2LoopbackCommandSentToFarEnd
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"DS2 Loopback Command Sent To Far End"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1960 }
facilityLoopback
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Facility Loopback"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1970 }
networkLoopback
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Network Loopback"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1980 }
terminalLoopback
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Terminal Loopback"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 1990 }
manuallyCausedAbnormalCondition
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "manually caused abnormal condition"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2000 }
ethernetBridgeIsNewRootOfSpanningTree
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Ethernet Bridge Is New Root Of Spanning Tree"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2010 }
ethernetBridgeTopologyChange
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Ethernet Bridge Topology Change"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2020 }
normalCondition
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "normal condition"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2030 }
embeddedOperationsChannelFailureLinkDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "embedded Operations Channel failure link down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2040 }
peerStateMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "peer state mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2050 }
proceduralError
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "procedural Error"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2060 }
improperRemoval
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Improper Removal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2070 }
duplicateNodeID
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Duplicate Node ID"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2080 }
blsrOutOfSync
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "BLSR out of sync"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2090 }
blsrMultiNodeTableUpdateCompleted
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"BLSR Multi-Node Table Update Completed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2100 }
protectionUnitNotAvailable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "protection unit not available"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2110 }
performanceMonitorThresholdCrossingAlert
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454ThresholdMonitorType,
cerent454ThresholdLocation,
cerent454ThresholdPeriod,
cerent454ThresholdSetValue,
cerent454ThresholdCurrentValue,
cerent454ThresholdDetectType,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "performance Monitor Threshold Crossing Alert"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2120 }
protectionSwitch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Protection Switch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2130 }
recoveryOrServiceProtectionActionHasBeenInitiated
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "recovery or service protection action has been initiated"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2140 }
automaticSystemReset
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "automatic system Reset"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2150 }
automaticUPSRSwitchCausedByAIS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "automatic UPSR switch caused by AIS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2160 }
automaticUPSRSwitchCausedByLOP
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "automatic UPSR switch caused by Lop"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2170 }
automaticUPSRSwitchCausedByUNEQ
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Automatic UPSR Switch Caused By UNEQ"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2180 }
automaticUPSRSwitchCausedByPDI
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "automatic UPSR switch caused by PDI"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2190 }
automaticUPSRSwitchCausedBySFBER
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Automatic UPSR Switch Caused By SFBER"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2200 }
automaticUPSRSwitchCausedBySDBER
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Automatic UPSR Switch Caused By SDBER"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2210 }
coldRestart
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "cold Restart"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2220 }
forcedSwitchBackToWorking
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Forced Switch Back To Working"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2230 }
forcedSwitchBackToWorkingRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Forced Switch Back To Working - Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2240 }
forcedSwitchBackToWorkingSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Forced Switch Back To Working - Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2250 }
forcedSwitchToProtection
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Forced Switch To Protection"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2260 }
forcedSwitchToProtectionRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Forced Switch To Protection - Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2270 }
forcedSwitchToProtectionSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Forced Switch To Protection - Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2280 }
workingFacilityOrEquipmentForcedToSwitchToProtectionPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Working Facility or Equipment Forced To Switch To Protection - Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2290 }
initializationInitiated
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "initialization initiated"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2300 }
lockoutOfProtection
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "lockout of Protection"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2310 }
lockoutOfProtectionRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "lockout of Protection Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2320 }
lockoutOfProtectionSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "lockout of Protection Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2330 }
lockoutOfProtectionPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "lockout of Protection Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2340 }
lockoutOfWorking
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "lockout of working"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2350 }
lockoutOfWorkingRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "lockout of working Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2360 }
lockoutOfWorkingSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "lockout of working Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2370 }
manualSystemReset
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "manual system Reset"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2380 }
manualSwitchToInternalClock
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Manual Switch to Internal Clock"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2390 }
manualSwitchToPrimaryReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Manual Switch To Primary Reference"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2400 }
manualSwitchToSecondReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Manual Switch To Second Reference"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2410 }
manualSwitchToThirdReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Manual Switch To Third reference"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2420 }
manualSwitchToFourthReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Manual Switch To Fourth reference"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2430 }
manualSwitchToFifthReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Manual Switch To Fifth reference"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2440 }
manualSwitchToSixthReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Manual Switch To Sixth reference"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2450 }
manualSwitchBackToWorking
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Manual Switch Back To Working"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2460 }
manualSwitchBackToWorkingRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Manual Switch Back To Working - Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2470 }
manualSwitchBackToWorkingSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Manual Switch Back To Working - Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2480 }
manualSwitchToProtection
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Manual Switch To Protection"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2490 }
manualSwitchToProtectionRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Manual Switch To Protection - Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2500 }
manualSwitchToProtectionSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Manual Switch To Protection - Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2510 }
manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Manual Switch Of Working Facility or Equipment To Protection - Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2520 }
powerfailRestart
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Powerfail Restart"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2530 }
ringIsSquelchingTraffic
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ring is squelching traffic"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2540 }
softwareDownloadInProgress
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "software download in progress"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2550 }
switchToInternalClock
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Switch To Internal clock"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2560 }
switchToPrimaryReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Switch To Primary refernce"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2570 }
switchToSecondReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Switch To Second Reference"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2580 }
switchToThirdReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Switch To Third refernce"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2590 }
switchToFourthReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Switch To Fourth refernce"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2600 }
switchToFifthReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Switch To Fifth refernce"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2610 }
switchToSixthReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Switch To Sixth refernce"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2620 }
systemReboot
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "system reboot"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2630 }
switchedBackToWorking
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Switched Back To Working"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2640 }
switchedToProtection
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Switched To Protection"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2650 }
warmRestart
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "warm Restart"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2660 }
ringIsInWaitToRestoreState
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Ring is in Wait To Restore state"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2670 }
manualSwitchRequest
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Manual Switch Request"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2680 }
forcedSwitchRequest
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Forced Switch Request"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2690 }
lockoutSwitchRequest
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Lockout Switch Request"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2700 }
rmonHistoriesAndAlarmsResetReboot
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"RMON Histories And Alarms Reset Reboot"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2710 }
rmonThresholdCrossingAlarm
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Crossing of Falling/Rising Threshold detected"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2720 }
alarmsSuppressedByUserCommand
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Alarms Suppressed By User Command"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2730 }
alarmsSuppressedForMaintenance
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Alarms Suppressed For Maintenance"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2740 }
switchingMatrixModuleFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Switching Matrix Module Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2750 }
lanConnectionPolarityReversed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Lan Connection Polarity Reversed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2760 }
autonomousPMReportMessageInhibited
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Autonomous PM Report Message Inhibited"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2780 }
ioSlotToXCONCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "IO Slot To XCON Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2790 }
stsPathTraceIdentifierMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "STS Path Trace Identifier Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2800 }
nePowerFailureAtConnectorA
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"NE Power Failure At Connector A"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2810 }
nePowerFailureAtConnectorB
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"NE Power Failure At Connector B"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2820 }
freeMemoryOnCardVeryLow
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Free memory on the card is very low"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2830 }
freeMemoryOnCardNearZero
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Free memory on the card is near zero"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2840 }
exerciseRequestOnRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Exercise Request on Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2850 }
exerciseRequestOnSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Exercise Request on Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2860 }
squelchingPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Squelching Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2870 }
extraTrafficPreempted
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Extra Traffic Preempted."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2880 }
farEndLockoutOfWorkingRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Far End Lockout of working - Ring."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2890 }
farEndLockoutOfWorkingSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Far End Lockout of working - Span."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2900 }
farEndLockoutOfProtectionRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Far End Lockout of Protection - Ring."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2910 }
farEndLockoutOfProtectionAllSpans
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Far End Lockout of Protection - All Spans."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2920 }
farEndWorkingFacilityForcedToSwitchToProtectionRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Far End Working Facility Forced To Switch To Protection - Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2930 }
farEndWorkingFacilityForcedToSwitchToProtectionSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Far End Working Facility Forced To Switch To Protection - Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2940 }
farEndManualSwitchOfWorkingFacilityToProtectionRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Far End Manual Switch Of Working Facility To Protection - Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2950 }
farEndManualSwitchOfWorkingFacilityToProtectionSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Far End Manual Switch Of Working Facility To Protection - Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2960 }
farEndExercisingRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Far End Exercising Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2970 }
farEndExercisingSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Far End Exercising Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2980 }
farEndBERThresholdPassedForSignalFailureRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Far End BER threshold passed for Signal Failure - Ring."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 2990 }
farEndBERThresholdPassedForSignalFailureSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Far End BER threshold passed for Signal Failure - Span."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3000 }
farEndBERThresholdPassedForSignalDegradeRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Far End BER threshold passed for Signal Degrade - Ring."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3010 }
farEndBERThresholdPassedForSignalDegradeSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Far End BER threshold passed for Signal Degrade - Span."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3020 }
apsChannelFarEndProtectionLineSignalDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"APS Channel - Far End Protection Line Signal Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3030 }
ringSwitchIsActiveOnTheEastSide
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Ring Switch is active on the East Side."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3040 }
ringSwitchIsActiveOnTheWestSide
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Ring Switch is active on the West Side."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3050 }
spanSwitchIsActiveOnTheEastSide
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Span Switch is active on the East Side."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3060 }
spanSwitchIsActiveOnTheWestSide
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Span Switch is active on the West Side."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3070 }
uniDirectionalFullPassThroughIsActive
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Uni-directional Full Pass Through is active."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3080 }
biDirectionalFullPassThroughIsActive
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Bi-directional Full Pass Through is active."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3090 }
kBytesPassThroughIsActive
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"K Bytes Pass Through Is Active"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3100 }
ringIsSegmented
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Ring is Segmented."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3110 }
ringTopologyIsUnderConstruction
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Ring Topology is under construction."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3120 }
lockoutOfProtectionAllSpans
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Lockout of Protection - All Spans."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3130 }
farEndOfFiberIsProvisionedWithDifferentRingID
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Far end of fiber is provisioned with different ring ID"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3140 }
bothEndsOfFiberProvisionedAsEastOrBothAsWest
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Both ends of fiber provisioned as East, or both as West"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3150 }
securityInvalidLoginUsernameSeeAuditTrail
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS deprecated
DESCRIPTION "Security: invalid login (see Audit Trail)"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3160 }
autonomousMessagesInhibited
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Autonomous messages inhibited"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3170 }
trafficStormOnLANLANTemporarilyDisabled
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Traffic Storm On LAN. LAN Temporarily Disabled"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3180 }
reptdbchgMessagesInhibited
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"REPT^DBCHG Messages Inhibited"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3190 }
securityUserIDHasExpired
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Security: User ID Has Expired"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3200 }
partialFanFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Partial Fan Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3210 }
forcedSwitchRequestOnRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Forced Switch Request On Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3220 }
forcedSwitchRequestOnSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Forced Switch Request On Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3230 }
lockoutSwitchRequestOnRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Lockout switch request on Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3240 }
lockoutSwitchRequestOnSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Lockout switch request on Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3250 }
manualSwitchRequestOnRing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Manual switch request on Ring"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3260 }
manualSwitchRequestOnSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Manual switch request on Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3270 }
communicationFailurePeerToPeerSlotControlBusA
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Peer to Peer Slot communication failure - Control Bus A"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3280 }
communicationFailurePeerToPeerSlotControlBusB
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Peer to Peer Slot communication failure - Control Bus B"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3290 }
controllerAToShelfSlotCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Controller A to shelf slot communication failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3300 }
controllerBToShelfSlotCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Controller B to shelf slot communication failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3310 }
interconnectionEquipmentFailureWorkingPayloadBus
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Interconnection Equipment Failure - Working Payload Bus"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3320 }
interconnectionEquipmentFailureProtectPayloadBus
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Interconnection Equipment Failure - Protect Payload Bus"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3330 }
inhibitSwitchToProtectRequestOnEquipment
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Inhibit Switch to Protect Request on equipment"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3340 }
inhibitSwitchToWorkingRequestOnEquipment
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Inhibit Switch to Working Request on equipment"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3350 }
berThresholdExceededForSignalDegradeLine
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "BER Threshold exceeded for Signal Degrade - Line"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3360 }
berThresholdExceededForSignalDegradePath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "BER Threshold exceeded for Signal Degrade - Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3370 }
berThresholdExceededForSignalFailureLine
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "BER Threshold Exceeded For Signal Failure - Line"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3380 }
berThresholdExceededForSignalFailurePath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "BER Threshold Exceeded For Signal Failure - Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3390 }
exercisingRingSuccessfully
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Exercising Ring Successfully"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3400}
exercisingSpanSuccessfully
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Exercising Span Successfully"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3410}
spanIsInWaitToRestoreState
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Span is in Wait To Restore state"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3420 }
exerciseRequestOnRingFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Exercise Request on Ring Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3430 }
exerciseRequestOnSpanFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Exercise Request on Span Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3440 }
farEndLockoutOfProtectionSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Far End Lockout Of Protection - Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3450 }
manufacturingDataMemoryEEPROMFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Manufacturing Data Memory (EEPROM) Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3460 }
replaceableEquipmentOrUnitIsMissing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Replaceable Equipment/Unit is Missing"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3470 }
softwareDownloadFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Software Download Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3480 }
extraTrafficPCADropped
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Extra Traffic (PCA) Dropped"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3490 }
etherTxOversubscribed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Ether tx oversubscribed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3500 }
etherRxOverSubscribed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Ether rx over subscribed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3510 }
etherTxExcessFlowCtrl
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Ether tx excess flow ctrl"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3520 }
etherRxExcessFlowCtrl
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Ether rx excess flow ctrl"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3530 }
transportLayerFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "transport layer failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3540 }
etherTxUnderrun
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Ether tx underrun"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3550 }
synchronizationReferenceFrequencyOutOfBounds
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Synchronization reference frequency out of bounds."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3560 }
ntpOrSntpHostFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "NTP/SNTP Host Failure."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3570 }
peerCardNotResponding
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Peer Card Not Responding"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3580 }
alarmsAndEventsSuppressedForThisObject
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Alarms and events suppressed for this object"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3590 }
ds3FrameFormatMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "DS3 Frame Format Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3600 }
waitToRestore
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Wait To Restore"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3610 }
extremeHighVoltBatteryA
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Extreme High Volt Battery A"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3620 }
extremeLowVoltBatteryA
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Extreme Low Volt Battery A"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3630 }
extremeHighVoltBatteryB
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Extreme High Volt Battery B"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3640 }
extremeLowVoltBatteryB
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Extreme Low Volt Battery B"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3650 }
iosConfigCopyFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "IOS config copy failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3660 }
iosConfigCopyInProgress
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "IOS config copy in progress"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3670 }
iosConfigCopySuccess
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "IOS Config Copy Success"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3680 }
-- Begin: UCP traps
signalingUnableToSetupCircuit
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Signaling Unable to setup circuit"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3710 }
errorInStartupConfig
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Error in Startup Config"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3712 }
noStartupConfig
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "No Startup Config"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3714 }
needToSaveRunningConfig
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Need to Save Running Config"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3716 }
invalidAlarm
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Invalid Alarm"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3718 }
rsvpHelloFSMToNeighborDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"RSVP Hello FSM to Neighbor down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3720 }
securityInvalidLoginUsername
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Security: Invalid Login - Username - See Audit Log"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3722 }
databaseBackupFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Database Backup Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3724 }
databaseRestoreFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Database Restore Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3726 }
lmpHelloFSMToControlChannelDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"LMP Hello FSM to Control Channel down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3730 }
lmpNeighborDiscoveryHasFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"LMP Neighbor Discovery has failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3740 }
unauthorizedIncomingSignalingRequest
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Unauthorized incoming signaling request"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3750 }
auditLog80PercentFull
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Audit Log 80 Percent Full"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3760 }
moduleCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Module Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3762 }
auditLog100PercentFullOldestRecordsWillBeLost
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Audit Log 100 Percent Full - Oldest records will be lost"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3764 }
standbyDatabaseOutOfSync
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Standby Database Out of Sync"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3766 }
redundantPowerCapabilityLost
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Redundant Power Capability Lost"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3768 }
-- End: UCP traps
forcedSwitchToPrimaryReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Forced Switch To Primary Reference"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3770 }
forcedSwitchToSecondReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Forced Switch To Second Reference"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3780 }
forcedSwitchToThirdReference
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Forced Switch To Third Reference"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3790 }
forcedSwitchToInternalClock
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Forced Switch To Internal Clock"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3800 }
industrialHighTemperature
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Industrial High Temperature"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 3805 }
-- Begin: SDH Traps
timSectionTraceIdentifierMismatchFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "TIM Section - Trace Identifier Mismatch Failure."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4000 }
aisMultiplexSectionAlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"AIS - Multiplex Section - Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4010 }
rdiMultiplexSectionRemoteDefectOrAlarmIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"RDI - Multiplex Section - Remote Defect/Alarm Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4020 }
timHighOrderTraceIdentifierMismatchFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TIM High Order - Trace Identifier Mismatch Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4030 }
aisAdministrationUnitAlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"AIS - Administration Unit - Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4040 }
lopAdministrationUnitLossOfPointer
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"LOP - Administration Unit - Loss of Pointer"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4050 }
slmfUnequippedHighOrderPathUnequipped
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"SLMF - Unequipped High Order - Path Unequipped"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4060 }
slmfPLMHighOrderPathLabelMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"SLMF - PLM High Order - Path Label Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4070 }
rdiHighOrderRemoteDefectOrAlarmIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"RDI - High Order - Remote Defect/Alarm Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4080 }
lopTributaryUnitLossOfPointer
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"LOP - Tributary Unit - Loss of Pointer"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4090 }
aisTributaryUnitAlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"AIS - Tributary Unit - Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4100 }
slmfUnequippedLowOrderPathUnequipped
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"SLMF - Unequipped Low Order - Path Unequipped"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4110 }
slmfPLMLowOrderPathLabelMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"SLMF - PLM Low Order - Path Label Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4120 }
timLowOrderTraceIdentifierMismatchFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"TIM Low Order - Trace Identifier Mismatch Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4130 }
rfiLowOrderRemoteFailureOrAlarmIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"RFI - Low Order - Remote Failure/Alarm Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4140 }
g811PrimaryReferenceClockTraceable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "G811 - Primary Reference Clock traceable."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4150 }
g812TransitNodeClockTraceable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "G812 - Transit Node Clock traceable."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4160 }
g812LocalNodeClockTraceable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "G812 - Local Node Clock traceable."
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4170 }
g813SynchronousEquipmentTimingSourceTraceable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"G813 - Synchronous Equipment Timing Source traceable"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4180 }
e1LoopbackDueToFEACCommand
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"E1 loopback due to FEAC command"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4190 }
e1LoopbackCommandSentToFarEnd
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"E1 loopback command sent to Far End"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4200 }
e3LoopbackDueToFEACCommand
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"E3 loopback due to FEAC command"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4210 }
farEndMultipleE1LOSDetectedOnE3
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end Multiple E1 LOS detected on E3"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4220 }
farEndE1EqptFailNonServiceAffecting
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end E1 eqpt fail non service affecting"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4230 }
farEndE1EqptFailServiceAffecting
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end E1 eqpt fail service affecting"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4240 }
farEndSingleE1LOS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end Single E1 LOS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4250 }
farEndE3EqptFailServiceAffecting
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end E3 eqpt fail service affecting"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4260 }
e3LoopbackCommandSentToFarEnd
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"E3 loopback command sent to far end"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4270 }
farEndE3EqptFailNonServiceAffecting
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "far end E3 eqpt fail non service affecting"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4280 }
lowVoltBatteryA
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Low Volt - Battery A"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4290 }
highVoltBatteryA
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "High Volt - Battery A"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4300 }
lowVoltBatteryB
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Low Volt - Battery B"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4310 }
highVoltBatteryB
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "High Volt - Battery B"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4320 }
msspRingOutOfSync
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "MS-SP ring out of sync"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4330 }
msspMultiNodeTableUpdateCompleted
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"MSSP Multi-Node Table Update Completed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4340 }
automaticSNCPSwitchCausedByAIS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "automatic SNCP switch caused by AIS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4350 }
automaticSNCPSwitchCausedByLOP
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "automatic SNCP switch caused by Lop"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4360 }
automaticSNCPSwitchCausedByUNEQ
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Automatic SNCP Switch caused by UNEQ"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4370 }
automaticSNCPSwitchCausedByPDI
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "automatic SNCP switch caused by PDI"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4380 }
automaticSNCPSwitchCausedBySFBER
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Automatic SNCP Switch caused by SFBER"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4390 }
automaticSNCPSwitchCausedBySDBER
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Automatic SNCP Switch caused by SDBER"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4400 }
stmConcatenationError
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"STM Concatenation error"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4410 }
e3IdleCondition
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"E3 Idle Condition"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4420 }
channelMSSPInconsistentAPSCode
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "channel MSSP inconsistent APS code"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4430 }
channelMSSPImproperAPSCodeAPS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "channel MSSP Improper APS code APS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4440 }
channelMSSPNodeIdMismatchAPS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "channel MSSP Node Id Mismatch APS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4450 }
channelMSSPDefaultKAPS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "channel MSSP Default K APS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4460 }
channelMSSPConnectionLossAPS
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "channel MSSP Connection loss APS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4470 }
minimumClockTraceableSDH
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "SDH Minimum clock Traceable"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4480 }
lineIsInWaitToRestoreStateSDH
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "SDH line is in Wait To Restore state "
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4490 }
berThresholdExceededForSignalDegradeHighOrder
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"BER Threshold Exceeded For Signal Degrade - High Order"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4500 }
berThresholdExceededForSignalFailureHighOrder
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"BER Threshold Exceeded For Signal Failure - High Order"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4510 }
berThresholdExceededForSignalDegradeLowOrder
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"BER Threshold Exceeded For Signal Degrade - Low Order"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4520 }
berThresholdExceededForSignalFailureLowOrder
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"BER Threshold Exceeded For Signal Failure - Low Order"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4530 }
failureToSwitchToProtectionHighOrderPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Failure To Switch To Protection - High Order Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4540 }
failureToSwitchToProtectionLowOrderPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Failure To Switch To Protection - Low Order Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4550 }
lofAdministrationUnitLossOfMultiFrame
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"LOF - Administration Unit - Loss of Multi Frame"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4560 }
sdhSpanIsInWaitToRestoreState
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "SDH span is in Wait To Restore state"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4570 }
-- End: SDH Traps
a8b10bOutOfSync
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "8B10B Out of Sync"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4755 }
odukPMAlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"ODUk: PM Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4760 }
otukAlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "OTUk: Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4765 }
otukSMBackwardDefectIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "OTUk: Backward Defect Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4770 }
odukBackwardDefectIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk: Backward Defect Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4775 }
fecUncorrectedWord
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "FEC Uncorrected Word"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4780 }
gccTerminationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "GCC Termination Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4785 }
otukIncomingAlignmentError
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "OTUk: Incoming Alignment Error"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4790 }
odukLockedDefectPM
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"ODUk: Locked Defect - PM"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4795 }
lossOfMultiFrame
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Loss of Multi-Frame"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4800 }
odukOpenConnectionIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk: Open Connection Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4805 }
payloadTypeIdentifierMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Payload Type Identifier Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4810 }
odukTrailTraceIdentifierMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk: Trail Trace Identifier Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4815 }
otukTrailTraceIdentifierMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "OTUk: Trail Trace Identifier Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4820 }
equipmentHighLaserBias
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment High Laser Bias"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4825 }
equipmentHighLaserTemp
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment High Laser Temp"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4830 }
equipmentHighLaserPeltier
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment High Laser Peltier"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4835 }
facilityHighRxPower
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Facility High Rx power"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4840 }
equipmentHighTxPower
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment High Tx power"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4845 }
equipmentHighTransceiverVoltage
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment High Transceiver voltage"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4850 }
equipmentLowLaserBias
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment Low Laser Bias"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4855 }
equipmentLowLaserTemp
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment Low Laser Temp"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4860 }
equipmentLowLaserPeltier
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment Low Laser Peltier "
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4865 }
facilityLowRxPower
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Facility Low Rx power"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4870 }
equipmentLowTxPower
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment Low Tx power"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4875 }
equipmentLowTransceiverVoltage
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment Low Transceiver voltage"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4880 }
equipmentRxLocked
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment Rx Locked"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4885 }
equipmentSquelched
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment Squelched"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4890 }
equipmentTxLocked
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment Tx Locked"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4895 }
otukSignalFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "OTUK Signal Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4900 }
odukSignalFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUK Signal Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4905 }
otukSignalDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "OTUK Signal Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4910 }
odukSignalDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUK Signal Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4915 }
pluggablePortMissing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Pluggable Port missing"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4920 }
pluggablePortRateMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Pluggable Port rate mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4925 }
pluggablePortSecurityCodeMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Pluggable Port security code mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4930 }
tciNotSelected
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Tci not selected"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4935 }
tci1ClockFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Tci 1 Clock Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4940 }
odukPMBackwardDefectIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk: PM Backward Defect Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4945 }
odukTCM1BackwardDefectIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk: TCM1 Backward Defect Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4950 }
odukTCM2BackwardDefectIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk: TCM2 Backward Defect Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4955 }
equipmentHighRxTemperature
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment High Rx temperature"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4960 }
equipmentLowRxTemperature
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment Low Rx temperature"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4965 }
tci2ClockFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Tci 2 Clock Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4970 }
equipmentWavelengthMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment Wavelength Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4975 }
dspCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "DSP Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4980 }
dspFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "DSP Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 4985 }
laserApproachingEndOfLife
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Laser Approaching End of Life"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5000 }
crossconnectLoopback
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Cross-connect Loopback"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5010 }
adminLogoutOfUser
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Admin Logout of User"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5020 }
userLockedOut
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "User Locked Out"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5030 }
adminLockoutOfUser
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Admin Lockout of User"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5040 }
adminLockoutClear
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Admin Lockout Clear"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5050 }
invalidLoginUsername
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Invalid Login: Username"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5060 }
securityInvalidLoginPassword
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Security: Invalid Login - Password - See Audit Log"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5070 }
securityInvalidLoginLockedOut
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Security: Invalid Login - Locked Out - See Audit Log"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5080 }
securityInvalidLoginAlreadyLoggedOn
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Security: Invalid Login - Already Logged On - See Audit Log"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5090 }
loginOfUser
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Login of User"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5100 }
automaticLogoutOfIdleUser
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Automatic Logout of IdleUser"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5110 }
logoutOfUser
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Logout of User"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5120 }
enhancedRemoteFailureIndicationPathServer
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Enhanced Remote Failure Indication - Path - Server"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5200 }
enhancedRemoteFailureIndicationPathConnectivity
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Enhanced Remote Failure Indication - Path - Connectivity"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5210 }
enhancedRemoteFailureIndicationPathPayload
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Enhanced Remote Failure Indication - Path - Payload"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5220 }
firewallHasBeenDisabled
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Firewall Has Been Disabled"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5230 }
securityIntrusionDetPwd
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Security Intrusion Attempt Detected - See Audit Log"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5240 }
securityIntrusionDetUser
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Security Intrusion Attempt Detected - See Audit Log"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5250 }
connectionEquipmentMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Connection Equipment Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5260 }
disableInactiveUser
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Disable Inactive User"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5270 }
disableInactiveClear
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Disable Inactive Clear"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5280 }
batteryFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Battery Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5290 }
extremeHighVolt
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Extreme High Volt"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5300 }
extremeLowVolt
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Extreme Low Volt"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5310 }
highVolt
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "High Volt"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5320 }
lowVolt
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Low Volt"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5330 }
suspendUser
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Suspend User"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5340 }
suspendUserClear
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Suspend User Clear"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5350 }
lineDccTerminationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Line DCC Termination Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5360 }
multiplexSectionDccTerminationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Multiplex Section DCC Termination Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5370 }
gigaBitEthernetOutOfSync
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"GigaBit Ethernet Out of Sync"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5380 }
sequenceMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Sequence Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5390 }
lossOfAlignment
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Loss of Alignment"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5400 }
outOfUseByAdministrativeCommand
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Out of Use - Administrative Command"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5410 }
outOfUseTransportFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Out of Use - Transport Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5420 }
vcatGroupDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "VCAT Group Down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5430 }
vcatGroupDegraded
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "VCAT Group Degraded"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5440 }
vcatGroupIncomplete
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "VCAT Group Incomplete"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5450 }
alarmIndicationSignalInTX
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Alarm Indication Signal in TX"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5460 }
remoteAlarmIndicationInTX
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Remote Alarm Indication in TX"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5470 }
kByteAPSChannelFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Kbyte Channel Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5480 }
apsInvalidMode
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "APS Invalid Mode"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5490 }
ipAddressAlreadyInUseWithinTheSameDccArea
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"IP Address A1ready In Use Within The Same DCC Area"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5500 }
nodeNameInUseWithinTheSameDccArea
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Node name already in use within the same DCC Area"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5510 }
rearPanelEthernetLinkRemoved
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Rear Panel Ethernet Link Removed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5520 }
manualSwitchToProtectResultedInNoTrafficSwitch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Manual Switch To Protect Resulted in No Traffic Switch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5530 }
manualSwitchBackToWorkingResultedInNoTrafficSwitch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Manual Switch Back To Working Resulted in No Traffic Switch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5540 }
forcedSwitchToProtectResultedInNoTrafficSwitch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Forced Switch To Protection Resulted in No Traffic Switch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5550 }
forcedSwitchBackToWorkingResultedInNoTrafficSwitch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Forced Switch Back To Working Resulted in No Traffic Switch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5560 }
duplicateSerialNumberDetectedOnAPluggableEntity
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Duplicate Serial number detected on a pluggable entity"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5570 }
lossOfSignalForOpticalChannel
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Incoming Payload Signal Absent"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5600 }
encapsulationMismatchPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Encapsulation Mismatch Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5610 }
encapsulationMismatchVT
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Encapsulation Mismatch - VT"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5620 }
encapsulationMismatchHighOrderPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Encapsulation Mismatch High Order - Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5630 }
encapsulationMismatchLowOrderPath
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Encapsulation Mismatch Low Order - Path"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5640 }
gfpUserPayloadMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "GFP User Payload Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5650 }
gfpFibreChannelDistanceExtensionMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "GFP Fibre Channel Distance Extension Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5660 }
gfpFibreChannelDistanceExtensionBufferStarvation
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "GFP Fibre Channel Distance Extension Buffer Starvation"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5670 }
gfpFibreChannelDistanceExtensionCreditStarvation
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Fibre Channel Distance Extension Credit Starvation"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5680 }
automaticWdmAnsFinished
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Automatic WDM ANS Finished"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5690 }
gfpClientSignalFailDetected
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "GFP Client Signal Fail Detected"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5700 }
gfpLossOfFrameDelineation
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "GFP Loss of Frame Delineation"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5710 }
gfpExtensionHeaderMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "GFP Extension Header Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5730 }
incomingOverheadSignalAbsent
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Incoming Overhead Signal Absent"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5740 }
opticalSafetyRemoteInterlockOn
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Safety Remote Interlock On"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5750 }
automaticPowerControlCorrectionSkipped
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Automatic Power Control Correction Skipped"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5770 }
apcCannotSetValueDueToRangeLimits
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "APC cannot set value due to range limits"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5780 }
lcasVcgMemberTxSideInAddState
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"LCAS VCG Member Tx Side In ADD State"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5790 }
farEndManualSwitchBackToWorkingSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Far End Manual Switch Back to Working - Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5800 }
farEndForcedSwitchBackToWorkingSpan
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Far End Forced Switch Back to Working - Span"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5810 }
universalTransponderModuleHardwareFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Universal Transponder Module Hardware Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5820 }
universalTransponderModuleCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Universal Transponder Module Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5830 }
pluginModuleRangeSettingsMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Plug-in Module Range Settings Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5840 }
lcasVcgMemberTxSideInDnuState
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"LCAS VCG Member Tx Side In DNU State"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5850 }
lcasControlWordCrcCheckFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"LCAS Control Word CRC Check Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5860 }
lcasVcgMemberRxSideInFailState
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"LCAS VCG Member Rx Side In FAIL State"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5870 }
signalLossOnDataInterface
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Signal Loss on Data Interface"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5880 }
synchronizationLossOnDataInterface
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Synchronization Loss on Data Interface"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5890 }
portFAIL
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "PORT FAIL"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5900 }
unreachablePortTargetPower
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Unreachable port target power"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5910 }
portAddPowerDegradeLow
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Port Add Power Degrade Low"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5920 }
portAddPowerDegradeHigh
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Port Add Power Degrade High"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5930 }
portAddPowerFailLow
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Port Add Power Fail Low"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5940 }
portAddPowerFailHigh
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Port Add Power Fail High"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 5950 }
automaticPowerControlTerminatedOnManualRequest
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Automatic Power Control Terminated on Manual request"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6000 }
oduk1AlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk-1: Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6010 }
oduk2AlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk-2: Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6020 }
oduk3AlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk-3: Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6030 }
oduk4AlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk-4: Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6040 }
temperatureReadingMismatchBetweenSCCards
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Temperature Reading Mismatch Between SC Cards"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6050 }
voltageReadingMismatchBetweenSCCards
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Voltage Reading Mismatch Between SC Cards"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6060 }
alarmsSuppressedonOutOfGroupVcatMember
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Alarms Suppressed on Out-Of-Group VCAT Member"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6070 }
blsrSoftwareVersionMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "BLSR Software Version Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6080 }
optimized1Plus1ApsPrimaryFacility
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Optimized 1+1 APS Primary Facility"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6090 }
optimized1Plus1ApsPrimarySectionMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Optimized 1+1 APS Primary Section Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6100 }
optimized1Plus1ApsInvalidPrimarySection
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Optimized 1+1 APS Invalid Primary Section"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6110 }
compositeClockHighLineVoltage
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Composite Clock High Line Voltage"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6120 }
berThresholdExceededForSignalDegradeVt
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"BER Threshold Exceeded For Signal Degrade - VT"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6130 }
berThresholdExceededForSignalFailureVt
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"BER Threshold Exceeded For Signal Failure - VT"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6140 }
spanLengthOutOfRange
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Span Length Out of Range"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6150 }
idleSignalCondition
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Idle Signal Condition"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6170 }
idleSignalConditionInTx
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Idle Signal Condition in TX"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6180 }
vtPathTraceIdentifierMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "VT Path Trace Identifier Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6190 }
lossOfFrameInTX
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Loss of Frame in TX"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6200 }
provisioningMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Provisioning Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6210 }
sectionTraceIdentifierMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Section Trace Identifier Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6220 }
regeneratorSectionTraceIdentifierMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Regenerator Section Trace Identifier Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6230 }
switchingMatrixModuleFailureWorking
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Switching Matrix Module Failure - Working"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6240 }
switchingMatrixModuleFailureProtect
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Switching Matrix Module Failure - Protect"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6250 }
slotCommunicationDisabled
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Slot Communication Disabled"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6260 }
sessionTimeLimitExpired
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Session Time Limit Expired"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6270 }
userPasswordChangeRequired
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "User Password Change Required"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6280 }
isisAdjacencyFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ISIS Adjacency Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6290 }
msspSoftwareVersionMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "MSSP Software Version Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6300 }
remoteAuthenticationFailSeeAuditLog
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Remote Authentication Fail - See Audit Log"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6310 }
ringIsSquelchingStsTraffic
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Ring Is Squelching STS Traffic"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6330 }
ringIsSquelchingVtTraffic
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Ring Is Squelching VT Traffic"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6340 }
archiveOfAuditLogFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Archival of Audit Log Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6350 }
rprWrapped
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "RPR Wrapped"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6360 }
shelfCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Shelf Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6370 }
duplicatedShelfIdentifier
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Duplicated Shelf Identifier"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6380 }
softwareMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Software Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6390 }
lmpFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "LMP Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6400 }
opticalTerminationIncomplete
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Termination Incomplete"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6410 }
forwardDefectIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Forward Defect Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6420 }
payloadMissingIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Payload Missing Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6430 }
spanMeasurementCannotBePerformed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Span loss not checked"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6440 }
ringIsSquelchingHighOrderTraffic
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Ring Is Squelching High Order Traffic"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6450 }
ringIsSquelchingLowOrderTraffic
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Ring Is Squelching Low Order Traffic"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6460 }
badPacketCountExceedsThreshold
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Bad Packet Count Exceeds Threshold"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6470 }
linkLayerKeepAliveFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Link Layer Keep-Alive Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6480 }
autonegotiationRemoteFailureIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Auto-Negotiation Remote Failure Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6490 }
trailSignalFail
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Trail Signal Fail"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6500 }
ds1LoopbackCommandSentToFarEnd
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "DS1 Loopback Command Sent To Far End"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6510 }
multiplexSectionSignalDegraded
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Multiplex Section - Signal Degraded"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6520 }
multiplexSectionExcessiveErrors
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Multiplex Section - Excessive Errors"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6530 }
highOrderPathSignalDegraded
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "High Order Path - Signal Degraded"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6540 }
highOrderPathExcessiveErrors
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "High Order Path - Excessive Errors"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6550 }
lowOrderPathSignalDegraded
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Low Order Path - Signal Degraded"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6560 }
lowOrderPathExcessiveErrors
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Low Order Path - Excessive Errors"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6570 }
regeneratorSectionDccTerminationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Regenerator Section - DCC Termination Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6580 }
networkMemoryPoolLow
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Network Memory Pool Low"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6590 }
ospfRoutingTableOverflow
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "OSPF Routing Table Overflow"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6600 }
autoLaserShutdownDisabled
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Auto Laser Shutdown Disabled"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6610 }
rprProtectionIsActive
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "RPR Protection Is Active"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6630 }
maxRPRStationNumberExceeded
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Max RPR Station Number Exceeded"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6640 }
rprProtectionConfigurationMismatched
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "RPR Protection Configuration Mismatched"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6650 }
reservedBandwidthLinkRateExceededOnRinglet0
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Reserved Bandwidth Link Rate Exceeded On Ringlet0"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6660 }
reservedBandwidthLinkRateExceededOnRinglet1
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Reserved Bandwidth Link Rate Exceeded On Ringlet1"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6670 }
rprInterfaceInPassThroughMode
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "RPR Interface In Pass Through Mode"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6680 }
rprPeerNodeIsMissing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "RPR Peer Node is Missing"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6690 }
rprRiFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"RPR RI Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6700 }
rprSignalFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "RPR Signal Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6710 }
rprSignalDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "RPR Signal Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6720 }
interlinkFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ADM Peer Cards Interlink Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6730 }
apcWrongGain
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "APC Wrong Gain Set Point"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6740 }
rprSpanMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "RPR Span Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6750 }
efmRemoteFaultIndicationCriticalEvent
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "EFM Remote Fault Inidication- Critical Event"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6760 }
efmRemoteFaultIndicationDyingGasp
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "EFM Remote Fault Inidication- Dying Gasp"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6770 }
efmRemoteFaultIndicationLinkFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "EFM Remote Fault Inidication- Link Fault"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6780 }
efmLinkMonitoringErroredSymbolPeriodEvent
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "EFM Link Monitoring- Errored Symbol Period Event"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6790 }
efmLinkMonitoringErroredFrameEvent
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "EFM Link Monitoring- Errored Frame Event"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6800 }
efmLinkMonitoringErroredFramePeriodEvent
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "EFM Link Monitoring- Errored Frame Period Event"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6810 }
efmLinkMonitoringErroredFrameSecondsSummary
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "EFM Link Monitoring- Errored Frame Seconds Summary"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6820 }
efmRemoteLoopbackRequestFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "EFM Remote Loopback Request Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6830 }
fastAutomaticProtectionSwitching
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Fast Automatic Protection Switching"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6840 }
fastAutomaticProtectionSwitchingConfigMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Fast Automatic Protection Switching Config Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6850 }
lcasSinkGroupError
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "LCAS Sink Group Error"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6860 }
lcasVcgMemberRxSideInDnuState
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "LCAS VCG Member Rx Side In DNU State"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6870 }
fcDistanceExtFuncNotEstablished
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION " Fibre Channel Distance Extension Function Not Established"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6880 }
nonCiscoPPMInserted
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Non Cisco PPM Inserted"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6890 }
unqualifiedPPMInserted
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Unqualified PPM Inserted"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6900 }
ftaMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "FanTray Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6910 }
cardPortsUnableToProvideProtection
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Card/Ports Unable To Provide Protection"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6920 }
lmpSignalDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "LMP Signal Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6930 }
lmpSignalFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "LMP Signal Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6940 }
lmpUnallocatedDataLink
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "LMP Unallocated Data Link"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6950 }
frontPortLinkLoss
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "TCC Front Port Link Loss"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6960 }
bertEnbl
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "BERT Enabled "
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6970 }
bertSyncFail
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "BERT Synchronization Status Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6975 }
workQueueFull
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Work Queue Full"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 6980 }
equipmentPowerFailureAtConnectorA
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment power failure at connector A"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7000 }
equipmentPowerFailureAtConnectorB
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment power failure at connector B"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7005 }
equipmentPowerFailureAtReturnConnectorA
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment power failure at return connector A"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7010 }
equipmentPowerFailureAtReturnConnectorB
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment power failure at return connector B"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7015 }
bridgeAndRollHasOccurred
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Bridge and Roll Has Occurred"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7055 }
bridgeAndRollIsPendingAValidSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Bridge and Roll is Pending a Valid Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7060 }
clockBusFailureTscA
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Clock Bus Failure - Shelf Controller A"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7160 }
clockBusFailureTscB
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Clock Bus Failure - Shelf Controller B"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7165 }
ospfHelloFail
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "OSPF Hello Fail"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7185 }
openIOSlots
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Open IO Slots"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7200 }
lossOfClockFromMateShelfController
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Loss of Clock from Mate Shelf Controller"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7210 }
virtualLanAlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Virtual Lan AIS"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7225 }
dcuLossFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "DCU Loss Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7230 }
ochncMaintenance
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "OCHNC Maintenance"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7235 }
ramanLaserShutdown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Raman Laser Shutdown"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7240 }
losOfRamanSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Loss Of Raman Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7245 }
mcastMacTableFull
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Multicast Mac Address Table Full"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7250 }
multicastMacAddressAliasing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Multicast Mac Address Aliasing"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7255 }
ramanPwrProtOn
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Raman Power Protection On"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7260 }
cppPeerNotResponding
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "CPP Peer Not Responding"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7265 }
voaControlLoopDisableDueToExcessiveCounterPropagationLight
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "VOA Control Loop Disable Due To Excessive Counter-Propagation Light"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7275 }
wizardIsRunning
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Wizard Is Running"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7280 }
ramanGainNotReached
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Raman Span Not Tuned"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7285 }
pprForwardDefectIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "pprForwardDefectIndication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7295 }
pprBackwardDefectIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "pprBackwardDefectIndication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7300 }
pprCoordinatedMaintenance
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "pprCoordinatedMaintenance"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7305 }
pprTriggerThresholdBERExceeded
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "pprTriggerThresholdBERExceeded"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7310 }
localFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Local Fault"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7315 }
remoteFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Remote Fault"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7320 }
efmRemoteLoopbackConfigured
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "EFM Port In Remote Loopback"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7325 }
efmPeerMissing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "EFM Link To Peer Missing"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7330 }
eqptDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Equipment Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7335 }
excessiveBackPropagation
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Excessive Back Propagation"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7340 }
remoteMaintenanceEndPointIsDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "CFM Remote Maintenance End Point Is Down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7345 }
crossConnectedCFMService
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Cross Connected CFM Service"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7350 }
cfmLoop
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "CFM Loop"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7355 }
cfmConfigurationError
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "CFM Configuration Error"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7360 }
outOfChannelGroupBundle
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Out Of Channel Group Bundle"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7365 }
repNeighborAdjacencyFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "REP Neighbor Adjacency Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7370 }
repLinkFlapping
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "REP Link Flapping"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7375 }
faultInREPSegment
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Fault In REP Segment"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7380 }
primaryREPEdgePortElected
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Primary REP Edge Port Elected"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7385 }
secondaryREPEdgePortElected
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Secondary REP Edge Port Elected"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7390 }
stcnREPGenerated
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "STCN REP Generated"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7395 }
vlbREPActivated
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "VLB REP Activated"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7400 }
vlbREPTriggerSoakingDelayActive
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "VLB REP Trigger Soaking Delay Active"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7405 }
wanSyncloss
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Ethernet Syncloss On WAN Port"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7410 }
laserShutdownDueToWavelengthDrift
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "laser Shutdown Due To Wavelength Drift"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7415 }
manualLaserRestart
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "manual Laser Restart"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7420 }
laserShutdownDueToNonCiscoPPMInserted
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "laserShutdownDueToNonCiscoPPMInserted"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7425 }
ethernetOSCTerminationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Ethernet OSC Termination Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7430 }
softwareSignatureVerificationFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "software Signature Verification Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7445 }
protectVolumeSoftwareSignatureVerificationFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Volume Software Signature Verification"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7450 }
activeVolumeSoftwareSignatureVerificationFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Active Software Signature Verification Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7455 }
peerPortClientSignalFailDetected
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Peer Port Client Signal Fail Detected"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7460 }
channelShutdownDueToWavelengthDrift
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Channel Shutdown Due to Wavelength Drift"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7465 }
usbWriteFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "USB Write Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7475 }
usbSyncInProgress
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "USB Sync in Progress"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7480 }
autoSensingUnableToDetectValidPayload
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Auto-Sensing Unable To Detect Valid Payload"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7485 }
payloadAutoSensingInProgress
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Payload Auto-Sensing In Progress"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7490 }
gfpClientSignalFailDetectedDueToSigloss
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "GFP Client Signal Fail Detected Due To Sigloss"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7495 }
gfpClientSignalFailDetectedDueToSyncloss
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "GFP Client Signal Fail Detected Due To Syncloss"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7500 }
pmdDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "PMD Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7510 }
standbyTccNEClockIsInternalClock
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Standby Tcc NE Clock Is Internal Clock"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7515 }
chromaticDispersionValue
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "chromatic Dispersion Value"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7520 }
packetTransportServiceFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Packet Transport Service Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7525 }
satellitePanelDiscoveryFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Satellite Panel Discovery Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7530 }
satellitePanelActiveLinkFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Satellite Panel Active Link Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7535 }
satellitePanelCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Satellite Panel Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7540 }
satellitePanelImproperConfiguration
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Satellite Panel Improper Configuration"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7545 }
satellitePanelFanMismatchOfEquipmentAndAttributes
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Satellite Panel Fan Mismatch Of Equipment And Attributes"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7550 }
satellitePanelFanFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Satellite Panel Fan Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7555 }
satellitePanelPartialFanFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Satellite Panel Partial Fan Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7560 }
satellitePanelFANManufacturingDataMemoryEEPROMFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Satellite Panel FAN Manufacturing Data Memory (EEPROM) Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7565 }
satellitePanelFANUnitIsMissing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Satellite Panel FAN Unit Is Missing"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7570 }
satellitePanelIndustrialHighTemperature
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Satellite Panel Industrial High Temperature"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7575 }
satellitePanelHighTemperature
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Satellite Panel High Temperature"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7580 }
satellitePanelBatteryFailureA
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Satellite Panel Battery Failure A"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7585 }
plannedSwitchOver
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Planned Switch Over"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7590 }
protectionCardConfigurationMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "protection CardConfiguration Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7595 }
routerProcessorSwitchOver
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Router Processor Switch Over"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7600 }
runningLowOnResources
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Running Low On Resources"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7605 }
noMoreResourcesAreAvailable
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "No More Resources Are Available"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7610 }
esmcFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ESMC Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7615 }
licenseWillExpireWithin24Hours
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "License Will Expire Within 24 Hours"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7620 }
licenseWillExpireAnytimeAfter1DayButBefore14Days
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "license Will Expire Anytime After 1Day But Before 14Days"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7625 }
licenseIsExpired
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "license Is Expired"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7630 }
licenseCountViolation
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "license Count Violation"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7635 }
temporaryLicenseIsInUse
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Temporary License Is In Use"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7640 }
evaluationLicenseIsInUse
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Evaluation License Is In Use"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7645 }
licenseIsMissing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "License Is Missing"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7650 }
pseudowireDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Pseudowire Down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7655 }
workingPseudowireControlPlaneDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Working Pseudowire Control Plane Down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7660 }
protectPseudowireControlPlaneDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Pseudowire Control Plane Down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7665 }
workingPseudowireConnectivityCheckDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Working Pseudowire Connectivity Check Down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7670 }
protectPseudowireConnectivityCheckDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Pseudowire Connectivity Check Down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7675 }
pseudowireTrafficSwitchedToProtection
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Pseudowire Traffic Switched To Pretection"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7680 }
workingPseudowireLocalAcTxPortFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Working Pseudowire Local AcTx Port Fault"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7685 }
protectPseudowireLocalAcTxPortFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Pseudowire Local AcTx Port Fault"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7690 }
workingPseudowireLocalAcRxPortFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Working Pseudowire Local AcRx Port Fault"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7695 }
protectPseudowireLocalAcRxPortFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Pseudowire Local AcRx Port Fault"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7700 }
workingPseudowireRemoteAcTxPortFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Working Pseudowire Remote AcTx Port Fault"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7705 }
protectPseudowireRemoteAcTxPortFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Pseudowire Remote AcTx Port Fault"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7710 }
workingPseudowireRemoteAcRxPortFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "working Pseudowire Remote AcRx Port Fault"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7715 }
protectPseudowireRemoteAcRxPortFault
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Pseudowire Remote AcRx Port Fault"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7720 }
slaThresholdCrossAlert
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "SLA Threshold Cross Alert"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7725 }
protectLocalPseudowireNotForwarding
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Local Pseudowire Not Forwarding"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7730 }
workingPseudowireNotForwarding
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Working Remote Pseudowire Not Forwarding"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7735 }
protectPseudowireNotForwarding
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Remote Pseudowire Not Forwarding"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7740 }
tpTunnelDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Tp Tunnel Down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7745 }
workingLabelSwitchedPathDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Working Label Switched Path Down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7750 }
protectLabelSwitchedPathDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Label Switched Path Down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7755 }
workingLabelSwitchedPathAlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Working Label Switched Path Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7760 }
protectLabelSwitchedPathAlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Label Switched Path Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7765 }
workingLabelSwitchedPathRemoteDefectIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Working Label Switched Path Remote Defect Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7770 }
protectLabelSwitchedPathRemoteDefectIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Label Switched Path Remote Defect Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7775 }
bidirectionalForwardDetectionDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Bidirectional Forward Detection Down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7780 }
tpTrafficSwitchedFromWorkingToProtection
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Tp Traffic Switched From Working To Protection"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7785 }
workingTpLockout
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "working Tp Lockout"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7790 }
protectTpLockout
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "protect Tp Lockout"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7795 }
ethernetFlowPointFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Ethernet Flow Point Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7800 }
teTunnelDown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "TE Tunnel Down"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7805 }
macSystemLimitReached
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "MAC System Limit Reached"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7810 }
macBridgeDomainLimitReached
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "MAC Bridge Domain Limit Reached"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7815 }
autoSensingDisabled
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Auto Sense Disabled"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7820 }
smBackwardIncomingAlignmentError
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "SM Backward Incoming Alignment Error"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7825 }
resourceAllocationFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Resource Allocation Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7830 }
lossOfDFBSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "loss Of DFB Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7835 }
workingLabelSwitchedPathLinkDownIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Working Label Switched Path Link Down Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7840 }
protectLabelSwitchedPathLinkDownIndication
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Label Switched Path Link Down Indication"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7845 }
workingLabelSwitchedPathLockReport
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Working Label Switched Path Lock Report"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7850 }
protectLabelSwitchedPathLockReport
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Protect Label Switched Path Lock Report"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7855 }
satellitePanelBatteryFailureB
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "satellite Panel Battery FailureB"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7860 }
highBitErrorRate
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "High Bit Error Rate"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7865 }
backPanelFacilityLoopback
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Back Panel Facility Loopback"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7870 }
backPanelTerminalLoopback
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Back Panel Terminal Loopback"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7875 }
trunkPayloadTypeMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Payload Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7880 }
invalidMuxponderConfiguration
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Invalid Muxponder Configuration"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7885 }
coolingProfileMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Cooling Profile Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7890 }
trunkOduAlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Trunk ODU: Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7895 }
companionCardMissing
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Companion Card Missing"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7900 }
controlPlaneUnverifiedClearedAlarmsPresent
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Control Plane Unverified Cleared Alarms Present"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7905 }
powerConsumptionLimitHasCrossed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Power Consumption Limit Has Crossed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7910 }
masterKeyExchangeFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Master Key Exchange Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7915 }
unitHighTemperature
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Unit High Temperature"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7930 }
overTemperatureUnitProtected
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Over Temperature Unit Protected"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7935 }
seqMismatchCount
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Sequence Mismatch Count"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7945 }
keyProgramOnAlteraFpgaFailed
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Key Program On Altera FPGA Failed"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7960 }
duplicateNodeControllerDetected
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Duplicate Node Controller Detected"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7970 }
restorationInProg
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Restoration in Progress"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7975 }
ramanPumpsCalibrationProcedureIsRunning
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Raman Calibration Running"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7980 }
ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Raman Calibration Pending"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 7985 }
odukTCM1AlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"ODUk: TCM1 Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13100 }
odukTCM2AlarmIndicationSignal
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"ODUk: TCM2 Alarm Indication Signal"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13105 }
odukLockedDefectTCM1
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk Locked Defect - TCM1"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13110 }
odukLockedDefectTCM2
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk Locked Defect - TCM2"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13115 }
otukLossOfFrame
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "OTUk: Loss Of Frame"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13120 }
odukOpenConnectionIndicationTCM1
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk Open Connection Indication TCM1"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13125 }
odukOpenConnectionIndicationTCM2
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk Open Connection Indication TCM2"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13130 }
odukTrailTraceIdentifierMismatchTCM1
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk Trail Trace Identifier Mismatch TCM1"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13135 }
odukTrailTraceIdentifierMismatchTCM2
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk Trail Trace Identifier Mismatch TCM2"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13140 }
odukSignalFailureTCM1
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk Signal Failure - TCM1"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13145 }
odukSignalFailureTCM2
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk Signal Failure - TCM2"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13150 }
odukSignalDegradeTCM1
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk Signal Degrade - TCM1"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13155 }
odukSignalDegradeTCM2
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "ODUk Signal Degrade - TCM2"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13160 }
lossOfChannel
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Loss of Channel"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13165 }
fecMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "FEC Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13170 }
timSectionMonitorTraceIdentifierMismatchFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "TIM Section Monitor - Trace Identifier Mismatch Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13175 }
automaticLaserShutdown
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Automatic Laser Shutdown"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13180 }
shutterInsertionLossVariationDegradeLow
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Shutter Insertion Loss Variation Degrade Low"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13200 }
opticalChannelDeactivationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Channel de-activation failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13205 }
shutterInsertionLossVariationDegradeHigh
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Shutter Insertion Loss Variation Degrade High"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13210 }
networkTopologyIncomplete
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Network Topology Incomplete"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13215 }
pluginModuleCommunicationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Plug-in Module Communication Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13220 }
opticalNetworkTypeMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Network Type Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13225 }
opticalPowerDegradeLow
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Optical Power Degrade Low"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13230 }
automaticPowerControlFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Automatic Power Control Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13235 }
opticalPowerDegradeHigh
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Power Degrade High"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13240 }
automaticPowerControlDisabled
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Automatic Power Control Disabled"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13245 }
opticalPowerFailureLow
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Power Failure Low"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13250 }
ringIdMismatch
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Ring Id Mismatch"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13255 }
opticalPowerFailureHigh
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Power Failure High"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13260 }
lossOfContinuity
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Loss Of Continuity"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13270 }
variableOpticalAttenuatorDegradeLow
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Variable Optical Attenuator Degrade Low"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13280 }
variableOpticalAttenuatorDegradeHigh
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Variable Optical Attenuator Degrade High"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13290 }
variableOpticalAttenuatorFailureLow
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Variable Optical Attenuator Failure Low"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13300 }
variableOpticalAttenuatorFailureHigh
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Variable Optical Attenuator Failure High"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13310 }
laserBiasDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Laser Bias Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13320 }
laserBiasFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "aser Bias Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13330 }
laserTemperatureDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Laser Temperature Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13340 }
opticalAmplifierGainDegradeLow
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Amplifier Gain Degrade Low"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13350 }
opticalAmplifierGainDegradeHigh
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Amplifier Gain Degrade High"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13360 }
opticalAmplifierGainFailureLow
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Amplifier Gain Failure Low"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13370 }
opticalAmplifierGainFailureHigh
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Amplifier Gain Failure High"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13380 }
opticalChannelConnectionFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Channel connection failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13390 }
opticalChannelIncomplete
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Channel Incomplete"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13395 }
opticalChannelActivationFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Channel activation failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13400 }
laserAutoPowerReduction
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Laser Auto Power Reduction"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13410 }
caseTemperatureDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Case Temperature Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13420 }
fiberTemperatureDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Fiber Temperature Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13430 }
shutterOpen
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Shutter Open"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13440 }
awgTemperatureDegrade
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "AWG Temperature Degrade"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13450 }
awgTemperatureFailure
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "AWG Temperature Failure"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13460 }
awgOverTemperature
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "AWG Over-Temperature"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13470 }
opticalAmplifierInitialization
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "Optical Amplifier Initialization"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13480 }
awgWarmUp
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION "AWG Warm Up"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13490 }
incSigloss
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Incoming Signal Loss on Fibre Channel Interface"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13510 }
incSyncloss
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Incoming Synchronization Loss on Fibre Channel Interface"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13515 }
incGfpOutOfFrame
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Out Of Frame Detected by GFP Receiver"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13520 }
incGfpSigLoss
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Client Signal Loss Frames Detected by GFP Receiver"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13525 }
incGfpSyncLoss
NOTIFICATION-TYPE
OBJECTS {
cerent454NodeTime,
cerent454AlarmState,
cerent454AlarmObjectType,
cerent454AlarmObjectIndex,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmObjectName,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting
}
STATUS current
DESCRIPTION
"Client Sychronization Loss Frames Detected by GFP Receiver"
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
--#GENERIC 6
--#SOURCE_ID "A"
--#TIMEINDEX 0
::= { cerent454V2Events 13530 }
node454Group OBJECT-GROUP
OBJECTS {
cerent454SoftwareVersion }
STATUS current
DESCRIPTION
"The group for node related objects"
::= { cerent454Groups 10 }
alarm454Group OBJECT-GROUP
OBJECTS {
cerent454AlarmCount,
cerent454AlarmObjectIndex,
cerent454AlarmObjectType,
cerent454AlarmSlotNumber,
cerent454AlarmPortNumber,
cerent454AlarmLineNumber,
cerent454AlarmType,
cerent454AlarmState,
cerent454AlarmSeverity,
cerent454AlarmStatus,
cerent454AlarmServiceAffecting,
cerent454AlarmTimeStamp,
cerent454AlarmObjectName,
cerent454AlarmAdditionalInfo
}
STATUS current
DESCRIPTION
"The group for node related objects"
::= { cerent454Groups 20 }
event454Group NOTIFICATION-GROUP
NOTIFICATIONS {
alarmUnknown,
alarmCutoffIsInManualMode,
failureDetectedExternalToTheNE,
externalError,
excessiveSwitching,
sdccTerminationFailure,
incomingFailureCondition,
alarmIndicationSignal,
alarmIndicationSignalLine,
alarmIndicationSignalPath,
alarmIndicationSignalVT,
apsChannelFailure,
channelByteFailureAPS,
channelProtectionSwitchingChannelMatchFailureAPS,
channelAutomaticProtectionSwitchModeMismatchAPS,
farEndProtectionLineFailure,
inconsistentAPSCode,
improperAPSCode,
nodeIdMismatch,
channelDefaultKAPS,
connectionLoss,
bipolarViolation,
carrierLossOnTheLAN,
concatenationErrorSTS,
excessCollisionsOnTheLAN,
facilityFailure,
farEndAIS,
farEndMultipleDS1LOSDetectedOnDS3,
farEndDS1EqptFailNonServiceAffecting,
farEndDS1EqptFailServiceAffecting,
farEndSingleDS1LOS,
farEndDS3EqptFailNonServiceAffecting,
farEndDS3EqptFailServiceAffecting,
farEndCommonEquipmentFailureNonServiceAffecting,
farEndIDLE,
farEndLOS,
farEndLOF,
farEndBlockError,
ds3IdleCondition,
lossOfFrame,
lossOfPointer,
lossOfPointerPath,
lossOfPointerVT,
lossOfSignal,
outOfFrame,
pathSelectorFailure,
remoteAlarmIndication,
remoteFailureIndication,
remoteFailureIndicationLine,
remoteFailureIndicationPath,
remoteFailureIndicationVT,
signalDegrade,
severelyErroredFrame,
signalFailure,
signalLabelMismatchFailure,
payloadDefectIndication,
payloadDefectIndicationPath,
payloadLabelMismatchPath,
signalLabelMismatchFailurePayloadLabelMismatchVT,
unequippedPath,
signalLabelMismatchFailureUnequippedVT,
lossOfSynchronization,
outOfSynchronization,
primarySynchronizationReferenceFailure,
secondarySynchronizationReferenceFailure,
thirdSynchronizationReferenceFailure,
fourthSynchronizationReferenceFailure,
fifthSynchronizationReferenceFailure,
sixthSynchronizationReferenceFailure,
failedToReceiveSynchronizationStatusMessage,
synchronizationStatusMessagesAreDisabledOnThisInterface,
stratum1PrimaryReferenceSourceTraceable,
synchronizedTraceabilityUnknown,
stratum2Traceable,
transitNodeClockTraceable,
stratum3ETraceable,
stratum3Traceable,
sonetMinimumClockTraceable,
stratum4Traceable,
doNotUseForSynchronization,
reservedForNetworkSynchronizationUse,
outgoingFailureCondition,
remoteDefectIndicationLine,
remoteDefectIndicationPath,
freeRunningSynchronizationMode,
holdoverSynchronizationMode,
fastStartSynchronizationMode,
internalFault,
internalError,
internalMessageError,
mismatchOfEquipmentAndAttributes,
watchdogTimerTimeout,
softwareFaultOrFailure,
softwareFaultDataIntegrityFault,
programFailure,
controlEquipmentFailure,
primaryNonVolatileBackupMemoryFailure,
secondaryNonVolatileBackupMemoryFailure,
controlBusFailure,
controlBus1Failure,
controlBus2Failure,
tccAToShelfSlot1DROP1CommunicationFailure,
tccAToShelfSlot2DROP2CommunicationFailure,
tccAToShelfSlot3DROP3CommunicationFailure,
tccAToShelfSlot4DROP4CommunicationFailure,
tccAToShelfSlot5TRUNK1CommunicationFailure,
tccAToShelfSlot6TRUNK2CommunicationFailure,
tccAToShelfSlot7TCCACommunicationFailure,
tccAToShelfSlot8XCONACommunicationFailure,
tccAToShelfSlot9AICCommunicationFailure,
tccAToShelfSlot10XCONBCommunicationFailure,
tccAToShelfSlot11TCCBCommunicationFailure,
tccAToShelfSlot12TRUNK3CommunicationFailure,
tccAToShelfSlot13TRUNK4CommunicationFailure,
tccAToShelfSlot14DROP5CommunicationFailure,
tccAToShelfSlot15DROP6CommunicationFailure,
tccAToShelfSlot16DROP7CommunicationFailure,
tccAToShelfSlot17DROP8CommunicationFailure,
tccAToDCCAProcessorCommunicationFailure,
tccBToShelfSlot1DROP1CommunicationFailure,
tccBToShelfSlot2DROP2CommunicationFailure,
tccBToShelfSlot3DROP3CommunicationFailure,
tccBToShelfSlot4DROP4CommunicationFailure,
tccBToShelfSlot5TRUNK1CommunicationFailure,
tccBToShelfSlot6TRUNK2CommunicationFailure,
tccBToShelfSlot7TCCACommunicationFailure,
tccBToShelfSlot8XCONACommunicationFailure,
tccBToShelfSlot9AICCommunicationFailure,
tccBToShelfSlot10XCONBCommunicationFailure,
tccBToShelfSlot11TCCBCommunicationFailure,
tccBToShelfSlot12TRUNK3CommunicationFailure,
tccBToShelfSlot13TRUNK4CommunicationFailure,
tccBToShelfSlot14DROP5CommunicationFailure,
tccBToShelfSlot15DROP6CommunicationFailure,
tccBToShelfSlot16DROP7CommunicationFailure,
tccBToShelfSlot17DROP8CommunicationFailure,
tccBToDCCBProcessorCommunicationFailure,
controlEquipmentControlCommunicationsEquipmentFailure,
controlProcessorFailure,
workingMemoryFailure,
interconnectionEquipmentFailure,
payloadBusFailureToIOSlot1XCONSlot8,
payloadBusFailureToIOSlot2XCONSlot8,
payloadBusFailureToIOSlot3XCONSlot8,
payloadBusFailureToIOSlot4XCONSlot8,
payloadBusFailureToIOSlot5XCONSlot8,
payloadBusFailureToIOSlot6XCONSlot8,
payloadBusFailureToIOSlot12XCONSlot8,
payloadBusFailureToIOSlot13XCONSlot8,
payloadBusFailureToIOSlot14XCONSlot8,
payloadBusFailureToIOSlot15XCONSlot8,
payloadBusFailureToIOSlot16XCONSlot8,
payloadBusFailureToIOSlot17XCONSlot8,
payloadBusFailureToIOSlot1XCONSlot10,
payloadBusFailureToIOSlot2XCONSlot10,
payloadBusFailureToIOSlot3XCONSlot10,
payloadBusFailureToIOSlot4XCONSlot10,
payloadBusFailureToIOSlot5XCONSlot10,
payloadBusFailureToIOSlot6XCONSlot10,
payloadBusFailureToIOSlot12XCONSlot10,
payloadBusFailureToIOSlot13XCONSlot10,
payloadBusFailureToIOSlot14XCONSlot10,
payloadBusFailureToIOSlot15XCONSlot10,
payloadBusFailureToIOSlot16XCONSlot10,
payloadBusFailureToIOSlot17XCONSlot10,
timeSlotInterchangeEquipmentFailure,
equipmentFailure,
highTemperature,
invalidMACAddress,
boardFailure,
diagnosticFailure,
mediumAccessControlFailure,
facilityTerminationEquipmentFailure,
automaticLaserShutoffDueToHighTemperature,
failureToReleaseFromProtection,
receiverFailure,
transmitFailure,
facilityTerminationEquipmentReceiverMissing,
facilityTerminationEquipmentTransmitterMissing,
failureToSwitchToProtection,
failureToSwitchToProtectionRing,
failureToSwitchToProtectionSpan,
failureToSwitchToProtectionPath,
fanFailure,
equipmentUnitPlugIn,
nePowerFailureAtConnector,
fuseAlarm,
synchronizationUnitFailure,
synchronizationSwitchingEquipmentFailure,
equipmentUnitUnplugged,
loopback,
ds1LoopbackDueToFEACCommand,
loopbackCommandSentToFarEndDS1,
ds3LoopbackDueToFEACCommand,
ds3LoopbackCommandSentToFarEnd,
ds2LoopbackDueToFarEndCommand,
ds2LoopbackCommandSentToFarEnd,
facilityLoopback,
networkLoopback,
terminalLoopback,
manuallyCausedAbnormalCondition,
ethernetBridgeIsNewRootOfSpanningTree,
ethernetBridgeTopologyChange,
normalCondition,
embeddedOperationsChannelFailureLinkDown,
peerStateMismatch,
proceduralError,
improperRemoval,
duplicateNodeID,
blsrOutOfSync,
blsrMultiNodeTableUpdateCompleted,
protectionUnitNotAvailable,
performanceMonitorThresholdCrossingAlert,
protectionSwitch,
recoveryOrServiceProtectionActionHasBeenInitiated,
automaticSystemReset,
automaticUPSRSwitchCausedByAIS,
automaticUPSRSwitchCausedByLOP,
automaticUPSRSwitchCausedByUNEQ,
automaticUPSRSwitchCausedByPDI,
automaticUPSRSwitchCausedBySFBER,
automaticUPSRSwitchCausedBySDBER,
coldRestart,
forcedSwitchBackToWorking,
forcedSwitchBackToWorkingRing,
forcedSwitchBackToWorkingSpan,
forcedSwitchToProtection,
forcedSwitchToProtectionRing,
forcedSwitchToProtectionSpan,
workingFacilityOrEquipmentForcedToSwitchToProtectionPath,
initializationInitiated,
lockoutOfProtection,
lockoutOfProtectionRing,
lockoutOfProtectionSpan,
lockoutOfProtectionPath,
lockoutOfWorking,
lockoutOfWorkingRing,
lockoutOfWorkingSpan,
manualSystemReset,
manualSwitchToInternalClock,
manualSwitchToPrimaryReference,
manualSwitchToSecondReference,
manualSwitchToThirdReference,
manualSwitchToFourthReference,
manualSwitchToFifthReference,
manualSwitchToSixthReference,
manualSwitchBackToWorking,
manualSwitchBackToWorkingRing,
manualSwitchBackToWorkingSpan,
manualSwitchToProtection,
manualSwitchToProtectionRing,
manualSwitchToProtectionSpan,
manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath,
powerfailRestart,
ringIsSquelchingTraffic,
softwareDownloadInProgress,
switchToInternalClock,
switchToPrimaryReference,
switchToSecondReference,
switchToThirdReference,
switchToFourthReference,
switchToFifthReference,
switchToSixthReference,
systemReboot,
switchedBackToWorking,
switchedToProtection,
warmRestart,
ringIsInWaitToRestoreState,
manualSwitchRequest,
forcedSwitchRequest,
lockoutSwitchRequest,
rmonHistoriesAndAlarmsResetReboot,
rmonThresholdCrossingAlarm,
alarmsSuppressedByUserCommand,
alarmsSuppressedForMaintenance,
switchingMatrixModuleFailure,
lanConnectionPolarityReversed,
autonomousPMReportMessageInhibited,
ioSlotToXCONCommunicationFailure,
stsPathTraceIdentifierMismatch,
nePowerFailureAtConnectorA,
nePowerFailureAtConnectorB,
freeMemoryOnCardVeryLow,
freeMemoryOnCardNearZero,
exerciseRequestOnRing,
exerciseRequestOnSpan,
squelchingPath,
extraTrafficPreempted,
farEndLockoutOfWorkingRing,
farEndLockoutOfWorkingSpan,
farEndLockoutOfProtectionRing,
farEndLockoutOfProtectionAllSpans,
farEndWorkingFacilityForcedToSwitchToProtectionRing,
farEndWorkingFacilityForcedToSwitchToProtectionSpan,
farEndManualSwitchOfWorkingFacilityToProtectionRing,
farEndManualSwitchOfWorkingFacilityToProtectionSpan,
farEndExercisingRing,
farEndExercisingSpan,
farEndBERThresholdPassedForSignalFailureRing,
farEndBERThresholdPassedForSignalFailureSpan,
farEndBERThresholdPassedForSignalDegradeRing,
farEndBERThresholdPassedForSignalDegradeSpan,
apsChannelFarEndProtectionLineSignalDegrade,
ringSwitchIsActiveOnTheEastSide,
ringSwitchIsActiveOnTheWestSide,
spanSwitchIsActiveOnTheEastSide,
spanSwitchIsActiveOnTheWestSide,
uniDirectionalFullPassThroughIsActive,
biDirectionalFullPassThroughIsActive,
kBytesPassThroughIsActive,
ringIsSegmented,
ringTopologyIsUnderConstruction,
lockoutOfProtectionAllSpans,
farEndOfFiberIsProvisionedWithDifferentRingID,
bothEndsOfFiberProvisionedAsEastOrBothAsWest,
autonomousMessagesInhibited,
trafficStormOnLANLANTemporarilyDisabled,
reptdbchgMessagesInhibited,
securityUserIDHasExpired,
partialFanFailure,
forcedSwitchRequestOnRing,
forcedSwitchRequestOnSpan,
lockoutSwitchRequestOnRing,
lockoutSwitchRequestOnSpan,
manualSwitchRequestOnRing,
manualSwitchRequestOnSpan,
communicationFailurePeerToPeerSlotControlBusA,
communicationFailurePeerToPeerSlotControlBusB,
controllerAToShelfSlotCommunicationFailure,
controllerBToShelfSlotCommunicationFailure,
interconnectionEquipmentFailureWorkingPayloadBus,
interconnectionEquipmentFailureProtectPayloadBus,
inhibitSwitchToProtectRequestOnEquipment,
inhibitSwitchToWorkingRequestOnEquipment,
exercisingRingSuccessfully,
exercisingSpanSuccessfully,
spanIsInWaitToRestoreState,
exerciseRequestOnRingFailed,
exerciseRequestOnSpanFailed,
farEndLockoutOfProtectionSpan,
manufacturingDataMemoryEEPROMFailure,
replaceableEquipmentOrUnitIsMissing,
softwareDownloadFailed,
extraTrafficPCADropped,
etherTxOversubscribed,
etherRxOverSubscribed,
etherTxExcessFlowCtrl,
etherRxExcessFlowCtrl,
transportLayerFailure,
etherTxUnderrun,
synchronizationReferenceFrequencyOutOfBounds,
ntpOrSntpHostFailure,
peerCardNotResponding,
alarmsAndEventsSuppressedForThisObject,
ds3FrameFormatMismatch,
timSectionTraceIdentifierMismatchFailure,
aisMultiplexSectionAlarmIndicationSignal,
rdiMultiplexSectionRemoteDefectOrAlarmIndication,
timHighOrderTraceIdentifierMismatchFailure,
aisAdministrationUnitAlarmIndicationSignal,
lopAdministrationUnitLossOfPointer,
slmfUnequippedHighOrderPathUnequipped,
slmfPLMHighOrderPathLabelMismatch,
rdiHighOrderRemoteDefectOrAlarmIndication,
lopTributaryUnitLossOfPointer,
aisTributaryUnitAlarmIndicationSignal,
slmfUnequippedLowOrderPathUnequipped,
slmfPLMLowOrderPathLabelMismatch,
timLowOrderTraceIdentifierMismatchFailure,
rfiLowOrderRemoteFailureOrAlarmIndication,
g811PrimaryReferenceClockTraceable,
g812TransitNodeClockTraceable,
g812LocalNodeClockTraceable,
g813SynchronousEquipmentTimingSourceTraceable,
e1LoopbackDueToFEACCommand,
e1LoopbackCommandSentToFarEnd,
e3LoopbackDueToFEACCommand,
farEndMultipleE1LOSDetectedOnE3,
farEndE1EqptFailNonServiceAffecting,
farEndE1EqptFailServiceAffecting,
farEndSingleE1LOS,
farEndE3EqptFailServiceAffecting,
e3LoopbackCommandSentToFarEnd,
farEndE3EqptFailNonServiceAffecting,
lowVoltBatteryA,
highVoltBatteryA,
lowVoltBatteryB,
highVoltBatteryB,
msspRingOutOfSync,
msspMultiNodeTableUpdateCompleted,
automaticSNCPSwitchCausedByAIS,
automaticSNCPSwitchCausedByLOP,
automaticSNCPSwitchCausedByUNEQ,
automaticSNCPSwitchCausedByPDI,
automaticSNCPSwitchCausedBySFBER,
automaticSNCPSwitchCausedBySDBER,
stmConcatenationError,
e3IdleCondition,
channelMSSPInconsistentAPSCode,
channelMSSPImproperAPSCodeAPS,
channelMSSPNodeIdMismatchAPS,
channelMSSPDefaultKAPS,
channelMSSPConnectionLossAPS,
minimumClockTraceableSDH,
lineIsInWaitToRestoreStateSDH,
berThresholdExceededForSignalDegradeHighOrder,
berThresholdExceededForSignalFailureHighOrder,
berThresholdExceededForSignalDegradeLowOrder,
berThresholdExceededForSignalFailureLowOrder,
failureToSwitchToProtectionHighOrderPath,
failureToSwitchToProtectionLowOrderPath,
a8b10bOutOfSync,
odukPMAlarmIndicationSignal,
otukAlarmIndicationSignal,
otukSMBackwardDefectIndication,
odukBackwardDefectIndication,
fecUncorrectedWord,
gccTerminationFailure,
otukIncomingAlignmentError,
odukLockedDefectPM,
lossOfMultiFrame,
odukOpenConnectionIndication,
payloadTypeIdentifierMismatch,
odukTrailTraceIdentifierMismatch,
otukTrailTraceIdentifierMismatch,
equipmentHighLaserBias,
equipmentHighLaserTemp,
equipmentHighLaserPeltier,
facilityHighRxPower,
equipmentHighTxPower,
equipmentHighTransceiverVoltage,
equipmentLowLaserBias,
equipmentLowLaserTemp,
equipmentLowLaserPeltier,
facilityLowRxPower,
equipmentLowTxPower,
equipmentLowTransceiverVoltage,
equipmentRxLocked,
equipmentSquelched,
equipmentTxLocked,
otukSignalFailure,
odukSignalFailure,
otukSignalDegrade,
odukSignalDegrade,
pluggablePortMissing,
pluggablePortRateMismatch,
pluggablePortSecurityCodeMismatch,
tciNotSelected,
tci1ClockFailure,
odukPMBackwardDefectIndication,
odukTCM1BackwardDefectIndication,
odukTCM2BackwardDefectIndication,
equipmentHighRxTemperature,
equipmentLowRxTemperature,
tci2ClockFailure,
equipmentWavelengthMismatch,
dspCommunicationFailure,
dspFailure,
laserApproachingEndOfLife,
crossconnectLoopback,
adminLogoutOfUser,
userLockedOut,
adminLockoutOfUser,
adminLockoutClear,
invalidLoginUsername,
securityInvalidLoginPassword,
securityInvalidLoginLockedOut,
securityInvalidLoginAlreadyLoggedOn,
loginOfUser,
automaticLogoutOfIdleUser,
logoutOfUser,
firewallHasBeenDisabled,
connectionEquipmentMismatch,
disableInactiveUser,
disableInactiveClear,
batteryFailure,
extremeHighVolt,
extremeLowVolt,
highVolt,
lowVolt,
suspendUser,
suspendUserClear,
lineDccTerminationFailure,
multiplexSectionDccTerminationFailure,
gigaBitEthernetOutOfSync,
sequenceMismatch,
lossOfAlignment,
outOfUseByAdministrativeCommand,
outOfUseTransportFailure,
vcatGroupDown,
vcatGroupDegraded,
vcatGroupIncomplete,
alarmIndicationSignalInTX,
remoteAlarmIndicationInTX,
kByteAPSChannelFailure,
apsInvalidMode,
ipAddressAlreadyInUseWithinTheSameDccArea,
nodeNameInUseWithinTheSameDccArea,
rearPanelEthernetLinkRemoved,
manualSwitchToProtectResultedInNoTrafficSwitch,
manualSwitchBackToWorkingResultedInNoTrafficSwitch,
forcedSwitchToProtectResultedInNoTrafficSwitch,
forcedSwitchBackToWorkingResultedInNoTrafficSwitch,
duplicateSerialNumberDetectedOnAPluggableEntity,
lossOfSignalForOpticalChannel,
encapsulationMismatchPath,
encapsulationMismatchVT,
encapsulationMismatchHighOrderPath,
encapsulationMismatchLowOrderPath,
gfpUserPayloadMismatch,
gfpFibreChannelDistanceExtensionMismatch,
gfpFibreChannelDistanceExtensionBufferStarvation,
gfpFibreChannelDistanceExtensionCreditStarvation,
gfpClientSignalFailDetected,
gfpLossOfFrameDelineation,
gfpExtensionHeaderMismatch,
lcasVcgMemberTxSideInAddState,
lcasVcgMemberTxSideInDnuState,
lcasControlWordCrcCheckFailure,
lcasVcgMemberRxSideInFailState,
signalLossOnDataInterface,
synchronizationLossOnDataInterface,
portFAIL,
unreachablePortTargetPower,
portAddPowerDegradeLow,
portAddPowerDegradeHigh,
portAddPowerFailLow,
portAddPowerFailHigh,
automaticWdmAnsFinished,
incomingOverheadSignalAbsent,
opticalSafetyRemoteInterlockOn,
automaticPowerControlCorrectionSkipped,
apcCannotSetValueDueToRangeLimits,
farEndManualSwitchBackToWorkingSpan,
farEndForcedSwitchBackToWorkingSpan,
universalTransponderModuleHardwareFailure,
universalTransponderModuleCommunicationFailure,
pluginModuleRangeSettingsMismatch,
automaticPowerControlTerminatedOnManualRequest,
oduk1AlarmIndicationSignal,
oduk2AlarmIndicationSignal,
oduk3AlarmIndicationSignal,
oduk4AlarmIndicationSignal,
temperatureReadingMismatchBetweenSCCards,
voltageReadingMismatchBetweenSCCards,
alarmsSuppressedonOutOfGroupVcatMember,
blsrSoftwareVersionMismatch,
optimized1Plus1ApsPrimaryFacility,
optimized1Plus1ApsPrimarySectionMismatch,
optimized1Plus1ApsInvalidPrimarySection,
compositeClockHighLineVoltage,
berThresholdExceededForSignalDegradeVt,
berThresholdExceededForSignalFailureVt,
spanLengthOutOfRange,
idleSignalCondition,
idleSignalConditionInTx,
vtPathTraceIdentifierMismatch,
lossOfFrameInTX,
provisioningMismatch,
sectionTraceIdentifierMismatch,
regeneratorSectionTraceIdentifierMismatch,
switchingMatrixModuleFailureWorking,
switchingMatrixModuleFailureProtect,
slotCommunicationDisabled,
sessionTimeLimitExpired,
userPasswordChangeRequired,
isisAdjacencyFailure,
msspSoftwareVersionMismatch,
remoteAuthenticationFailSeeAuditLog,
ringIsSquelchingStsTraffic,
ringIsSquelchingVtTraffic,
archiveOfAuditLogFailed,
rprWrapped,
shelfCommunicationFailure,
duplicatedShelfIdentifier,
softwareMismatch,
lmpFailure,
opticalTerminationIncomplete,
forwardDefectIndication,
payloadMissingIndication,
spanMeasurementCannotBePerformed,
ringIsSquelchingHighOrderTraffic,
ringIsSquelchingLowOrderTraffic,
badPacketCountExceedsThreshold,
linkLayerKeepAliveFailure,
autonegotiationRemoteFailureIndication,
trailSignalFail,
ds1LoopbackCommandSentToFarEnd,
multiplexSectionSignalDegraded,
multiplexSectionExcessiveErrors,
highOrderPathSignalDegraded,
highOrderPathExcessiveErrors,
lowOrderPathSignalDegraded,
lowOrderPathExcessiveErrors,
regeneratorSectionDccTerminationFailure,
networkMemoryPoolLow,
ospfRoutingTableOverflow,
autoLaserShutdownDisabled,
rprProtectionIsActive,
maxRPRStationNumberExceeded,
rprProtectionConfigurationMismatched,
reservedBandwidthLinkRateExceededOnRinglet0,
reservedBandwidthLinkRateExceededOnRinglet1,
rprInterfaceInPassThroughMode,
rprPeerNodeIsMissing,
rprRiFailure,
rprSignalFailure,
rprSignalDegrade,
interlinkFailure,
apcWrongGain,
rprSpanMismatch,
efmRemoteFaultIndicationCriticalEvent,
efmRemoteFaultIndicationDyingGasp,
efmRemoteFaultIndicationLinkFault,
efmLinkMonitoringErroredSymbolPeriodEvent,
efmLinkMonitoringErroredFrameEvent,
efmLinkMonitoringErroredFramePeriodEvent,
efmLinkMonitoringErroredFrameSecondsSummary,
efmRemoteLoopbackRequestFailed,
fastAutomaticProtectionSwitching,
fastAutomaticProtectionSwitchingConfigMismatch,
lcasSinkGroupError,
lcasVcgMemberRxSideInDnuState,
fcDistanceExtFuncNotEstablished,
nonCiscoPPMInserted,
unqualifiedPPMInserted,
ftaMismatch,
cardPortsUnableToProvideProtection,
lmpSignalDegrade,
lmpSignalFailure,
lmpUnallocatedDataLink,
frontPortLinkLoss,
bertEnbl,
bertSyncFail,
workQueueFull,
equipmentPowerFailureAtConnectorA,
equipmentPowerFailureAtConnectorB,
equipmentPowerFailureAtReturnConnectorA,
equipmentPowerFailureAtReturnConnectorB,
ospfHelloFail,
openIOSlots,
lossOfClockFromMateShelfController,
virtualLanAlarmIndicationSignal,
dcuLossFailure,
ochncMaintenance,
ramanLaserShutdown,
losOfRamanSignal,
mcastMacTableFull,
multicastMacAddressAliasing,
ramanPwrProtOn,
cppPeerNotResponding,
voaControlLoopDisableDueToExcessiveCounterPropagationLight,
wizardIsRunning,
ramanGainNotReached,
localFault,
remoteFault,
efmRemoteLoopbackConfigured,
efmPeerMissing,
eqptDegrade,
excessiveBackPropagation,
remoteMaintenanceEndPointIsDown,
crossConnectedCFMService,
cfmLoop,
cfmConfigurationError,
outOfChannelGroupBundle,
repNeighborAdjacencyFailure,
repLinkFlapping,
faultInREPSegment,
primaryREPEdgePortElected,
secondaryREPEdgePortElected,
stcnREPGenerated,
vlbREPActivated,
vlbREPTriggerSoakingDelayActive,
pprForwardDefectIndication,
pprBackwardDefectIndication,
pprCoordinatedMaintenance,
pprTriggerThresholdBERExceeded,
wanSyncloss,
laserShutdownDueToWavelengthDrift,
manualLaserRestart,
laserShutdownDueToNonCiscoPPMInserted,
ethernetOSCTerminationFailure,
enhancedRemoteFailureIndicationPathServer,
enhancedRemoteFailureIndicationPathConnectivity,
enhancedRemoteFailureIndicationPathPayload,
securityIntrusionDetPwd,
securityIntrusionDetUser,
backPanelFacilityLoopback,
backPanelTerminalLoopback,
trunkPayloadTypeMismatch,
invalidMuxponderConfiguration,
coolingProfileMismatch,
trunkOduAlarmIndicationSignal,
companionCardMissing,
masterKeyExchangeFailed,
powerConsumptionLimitHasCrossed,
controlPlaneUnverifiedClearedAlarmsPresent,
unitHighTemperature,
overTemperatureUnitProtected,
seqMismatchCount,
keyProgramOnAlteraFpgaFailed,
duplicateNodeControllerDetected,
restorationInProg,
ramanPumpsCalibrationProcedureIsRunning,
ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes,
odukTCM1AlarmIndicationSignal,
odukTCM2AlarmIndicationSignal,
odukLockedDefectTCM1,
odukLockedDefectTCM2,
otukLossOfFrame,
odukOpenConnectionIndicationTCM1,
odukOpenConnectionIndicationTCM2,
odukTrailTraceIdentifierMismatchTCM1,
odukTrailTraceIdentifierMismatchTCM2,
odukSignalFailureTCM1,
odukSignalFailureTCM2,
odukSignalDegradeTCM1,
odukSignalDegradeTCM2,
lossOfChannel,
fecMismatch,
timSectionMonitorTraceIdentifierMismatchFailure,
automaticLaserShutdown,
shutterInsertionLossVariationDegradeLow,
opticalChannelDeactivationFailure,
shutterInsertionLossVariationDegradeHigh,
networkTopologyIncomplete,
pluginModuleCommunicationFailure,
opticalNetworkTypeMismatch,
forcedSwitchToPrimaryReference,
forcedSwitchToSecondReference,
forcedSwitchToThirdReference,
forcedSwitchToInternalClock,
industrialHighTemperature,
opticalPowerDegradeLow,
automaticPowerControlFailure,
opticalPowerDegradeHigh,
automaticPowerControlDisabled,
opticalPowerFailureLow,
ringIdMismatch,
opticalPowerFailureHigh,
lossOfContinuity,
variableOpticalAttenuatorDegradeLow,
variableOpticalAttenuatorDegradeHigh,
variableOpticalAttenuatorFailureLow,
variableOpticalAttenuatorFailureHigh,
laserBiasDegrade,
laserBiasFailure,
laserTemperatureDegrade,
opticalAmplifierGainDegradeLow,
opticalAmplifierGainDegradeHigh,
opticalAmplifierGainFailureLow,
opticalAmplifierGainFailureHigh,
opticalChannelConnectionFailure,
opticalChannelIncomplete,
opticalChannelActivationFailure,
laserAutoPowerReduction,
caseTemperatureDegrade,
fiberTemperatureDegrade,
shutterOpen,
awgTemperatureDegrade,
awgTemperatureFailure,
awgOverTemperature,
opticalAmplifierInitialization,
awgWarmUp,
incSigloss,
incSyncloss,
incGfpOutOfFrame,
incGfpSigLoss,
incGfpSyncLoss,
bridgeAndRollHasOccurred,
bridgeAndRollIsPendingAValidSignal,
clockBusFailureTscA,
clockBusFailureTscB,
waitToRestore,
extremeHighVoltBatteryA,
extremeLowVoltBatteryA,
extremeHighVoltBatteryB,
extremeLowVoltBatteryB,
iosConfigCopyFailed,
iosConfigCopyInProgress,
iosConfigCopySuccess,
signalingUnableToSetupCircuit,
errorInStartupConfig,
noStartupConfig,
needToSaveRunningConfig,
invalidAlarm,
rsvpHelloFSMToNeighborDown,
securityInvalidLoginUsername,
databaseBackupFailed,
databaseRestoreFailed,
lmpHelloFSMToControlChannelDown,
lmpNeighborDiscoveryHasFailed,
auditLog80PercentFull,
moduleCommunicationFailure,
auditLog100PercentFullOldestRecordsWillBeLost,
standbyDatabaseOutOfSync,
redundantPowerCapabilityLost,
lofAdministrationUnitLossOfMultiFrame,
sdhSpanIsInWaitToRestoreState,
berThresholdExceededForSignalDegradeLine,
berThresholdExceededForSignalDegradePath,
berThresholdExceededForSignalFailureLine,
berThresholdExceededForSignalFailurePath,
unauthorizedIncomingSignalingRequest
}
STATUS current
DESCRIPTION
"The notifications for Cisco ONS 15454"
::= { cerent454Groups 30 }
-- This definition of group will move to a cerentCommon modules
-- eventually.
cerent454CommonGroup OBJECT-GROUP
OBJECTS {
-- cerentNotificationCategory,
cerent454EnableNotification,
cerent454NodeTime,
cerent454SentNotifications,
cerent454LastChangeTime,
cerent454MultishelfEnabled
}
STATUS current
DESCRIPTION
"The objects for storing all the current alarms"
::= { cerent454Groups 40 }
-- This group covers for threshold display and TCA trap
cerentThresholdGroup OBJECT-GROUP
OBJECTS {
cerent454ThresholdMonitorType,
cerent454ThresholdLocation,
cerent454ThresholdPeriod,
cerent454ThresholdSetValue,
cerent454ThresholdCurrentValue,
cerent454ThresholdDetectType
}
STATUS current
DESCRIPTION
"The objects for storing all the current alarms"
::= { cerent454Groups 50 }
event454DeprecatedGroup NOTIFICATION-GROUP
NOTIFICATIONS {
securityInvalidLoginUsernameSeeAuditTrail
}
STATUS deprecated
DESCRIPTION
"The notifications for Cisco ONS 15454 that have been deprecated"
::= { cerent454Groups 60 }
reportedAlarm454Group OBJECT-GROUP
OBJECTS {
cerent454ReportedAlarmCount,
cerent454ReportedAlarmObjectType,
cerent454ReportedAlarmSlotNumber,
cerent454ReportedAlarmPortNumber,
cerent454ReportedAlarmObjectIndex,
cerent454ReportedAlarmType,
cerent454ReportedAlarmTimeStamp,
cerent454ReportedAlarmObjectName,
cerent454ReportedAlarmAdditionalInfo,
cerent454ReportedAlarmSeverity,
cerent454ReportedAlarmStatus,
cerent454ReportedAlarmServiceAffecting
}
STATUS current
DESCRIPTION
"The group for reported alarm objects"
::= { cerent454Groups 80 }
-- the compliance specification for agent developers
cerent454BasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The basic implementation requirements for Cisco ONS 15454 MIB"
MODULE
MANDATORY-GROUPS {
node454Group,
event454Group
}
::= { cerent454Compliance 10 }