-- CISCO-CAT6K-CROSSBAR-MIB.my
|
|
--
|
|
-- Mar 2001, Padma Pullela
|
|
-- Nov. 2002, Padma Pullela/Lilian Jiang
|
|
-- March 2003, Padma Pullela
|
|
-- June 2004, Padma Pullela
|
|
--
|
|
-- Copyright (c) 2001-2009, 2012-2013 by cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
-- *****************************************************************
|
|
|
|
CISCO-CAT6K-CROSSBAR-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Counter32,
|
|
Unsigned32,
|
|
Gauge32,
|
|
NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP,
|
|
NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION,
|
|
TruthValue,
|
|
DisplayString,
|
|
DateAndTime,
|
|
TimeStamp
|
|
FROM SNMPv2-TC
|
|
entPhysicalName,
|
|
entPhysicalVendorType,
|
|
entPhysicalIndex,
|
|
entPhysicalDescr
|
|
FROM ENTITY-MIB
|
|
Percent
|
|
FROM CISCO-QOS-PIB-MIB
|
|
ciscoMgmt
|
|
FROM CISCO-SMI;
|
|
|
|
|
|
ciscoCat6kCrossbarMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201309160000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
"Cisco Systems
|
|
Customer Service
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
Tel: +1 800 553-NETS
|
|
|
|
E-mail: cs-cat6000@cisco.com"
|
|
DESCRIPTION
|
|
"The Catalyst 6000 Crossbar MIB provides instrumentation for
|
|
configuration and operation of the crossbar switching fabric
|
|
module, and additional functionalities for switching bus
|
|
and internal bus, etc."
|
|
REVISION "201309160000Z"
|
|
DESCRIPTION
|
|
"Added two new enumerations 'pfc4xxl' and 'pfc4lite'
|
|
in cc6kxbarSysCapPfcOperMode."
|
|
REVISION "201205310000Z"
|
|
DESCRIPTION
|
|
"Added following OBJECT-GROUP
|
|
- cc6kxbarStatisticsLbusDropGroup
|
|
Added new compliance
|
|
- cc6kxbarMIBComplianceVer8.
|
|
Updated the description for
|
|
- cc6kxbarStatisticsPeakTmInUtil
|
|
- cc6kxbarStatisticsPeakTmOutUtil."
|
|
REVISION "200902150000Z"
|
|
DESCRIPTION
|
|
"Added cc6kxbarErrRcvryPersLinkResGroup and
|
|
cc6kxbarErrRcvryChResyncGroup,
|
|
cc6kxbarTMSwBusUtilGroup,
|
|
cc6kxbarTMSwBusUtilNotifControlGroup,
|
|
cc6kxbarTMSwBusUtilNotifObjectGroup,
|
|
cc6kxbarTMSwBusUtilNotifGroup,
|
|
cc6kxbarTMChUtilGroup,
|
|
cc6kxbarTMChUtilNotifControlGroup,
|
|
cc6kxbarTMChUtilNotifObjectGroup,
|
|
cc6kxbarTMChUtilNotifGroup.
|
|
|
|
Added two new enumerations 'pfc4' and 'pfc4xl'
|
|
in cc6kxbarSysCapPfcOperMode.
|
|
|
|
Added DISPLAY-HINT in TEXTUAL-CONVENTION
|
|
of ModuleSlotNumber and FabricChannelNumber."
|
|
REVISION "200712180000Z"
|
|
DESCRIPTION
|
|
"Added cc6kxbarSysCapPfcOperModeGroup,
|
|
cc6kxbarSysCapSwitchResGroup, cc6kxbarChannelUtilGroup1,
|
|
cc6kxbarSwBusGroup1, cc6kxbarErrorGroup,
|
|
cc6kxbarErrRcvryThresholdGroup and
|
|
cc6kxbarErrRcvrySwitchoverGroup."
|
|
REVISION "200612190000Z"
|
|
DESCRIPTION
|
|
"Added cc6kxbarDcefOnlyModeAllowedGroup,
|
|
cc6kxbarForceBusModeGroup,
|
|
cc6kxbarFlowCtrlNotifCtrlGroup,
|
|
cc6kxbarFlowCtrlBusThreshGroup,
|
|
cc6kxbarFlowCtrlBusThrNotifGroup
|
|
and cc6kxbarBusOnlyModeOperGroup."
|
|
REVISION "200411190000Z"
|
|
DESCRIPTION
|
|
"Added cc6kxbarIntBusCRCErrGroup."
|
|
REVISION "200408110000Z"
|
|
DESCRIPTION
|
|
"Added cc6kxbarIntBusNotifControlGroup and
|
|
cc6kxbarIntBusCRCErrNotifGroup."
|
|
REVISION "200406110000Z"
|
|
DESCRIPTION
|
|
"Added cc6kxbarTruncatedModeOper Object and changed the
|
|
description of cc6kxbarTruncatedModeAllowed and
|
|
cc6kxbarMinFabricPresent."
|
|
REVISION "200309290000Z"
|
|
DESCRIPTION
|
|
"Changed the description of cc6kxbarTruncatedModeAllowed and
|
|
cc6kxbarMinFabricPresent. Removed default value for
|
|
cc6kxbarTruncatedModeAllowed."
|
|
REVISION "200304020000Z"
|
|
DESCRIPTION
|
|
"Changed the SYNTAX and description of cc6kxbarMinFabricPresent
|
|
and description of cc6kxbarTruncatedModeAllowed."
|
|
REVISION "200212050000Z"
|
|
DESCRIPTION
|
|
"Added cc6kxbarModuleChannelSpeed, cc6kxbarSwBusSwitchingStatus,
|
|
cc6kxbarSwBusFailureDuration, cc6kxbarSwBusNotifEnable
|
|
objects and cc6kxbarSwBusStallNotif notification."
|
|
REVISION "200106250000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { ciscoMgmt 217 }
|
|
|
|
|
|
ciscoCat6kXbarMIBObjects OBJECT IDENTIFIER
|
|
::= { ciscoCat6kCrossbarMIB 1 }
|
|
|
|
cc6kxbarConfiguration OBJECT IDENTIFIER
|
|
::= { ciscoCat6kXbarMIBObjects 1 }
|
|
|
|
cc6kxbarStatus OBJECT IDENTIFIER
|
|
::= { ciscoCat6kXbarMIBObjects 2 }
|
|
|
|
cc6kxbarStatistics OBJECT IDENTIFIER
|
|
::= { ciscoCat6kXbarMIBObjects 3 }
|
|
|
|
cc6kxbarSwBusObjects OBJECT IDENTIFIER
|
|
::= { ciscoCat6kXbarMIBObjects 4 }
|
|
|
|
cc6kxbarIntBusObjects OBJECT IDENTIFIER
|
|
::= { ciscoCat6kXbarMIBObjects 5 }
|
|
|
|
cc6kxbarFlowCtrlObjects OBJECT IDENTIFIER
|
|
::= { ciscoCat6kXbarMIBObjects 6 }
|
|
|
|
cc6kxbarSystemCapacityObjects OBJECT IDENTIFIER
|
|
::= { ciscoCat6kXbarMIBObjects 7 }
|
|
|
|
cc6kxbarErrorRecoveryObjects OBJECT IDENTIFIER
|
|
::= { ciscoCat6kXbarMIBObjects 8 }
|
|
|
|
cc6kxbarTrafficMonitorObjects OBJECT IDENTIFIER
|
|
::= { ciscoCat6kXbarMIBObjects 9 }
|
|
|
|
cc6kxbarTrafficMonitorSwBusObjects OBJECT IDENTIFIER
|
|
::= { cc6kxbarTrafficMonitorObjects 1 }
|
|
|
|
cc6kxbarTrafficMonitorChObjects OBJECT IDENTIFIER
|
|
::= { cc6kxbarTrafficMonitorObjects 2 }
|
|
|
|
|
|
-- Textual Conventions
|
|
|
|
ModuleSlotNumber ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot number of the module."
|
|
SYNTAX Unsigned32
|
|
|
|
FabricChannelNumber ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fabric channel number."
|
|
SYNTAX Unsigned32
|
|
|
|
ChannelStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the Channel."
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
syncError(2),
|
|
heartbeatError(3),
|
|
crcError(4),
|
|
bufferError(5),
|
|
timeoutError(6),
|
|
unused(7)
|
|
}
|
|
|
|
-- Configuration objects
|
|
|
|
cc6kxbarFallbackMode OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cc6kxbarFallbackMode controls system fallback to bus-mode
|
|
after loss of switching fabric module.
|
|
'true' - When the last fabric card is removed
|
|
system will adjust the supervisor and
|
|
line cards switching mode automatically without
|
|
resetting the system. With this feature enabled,
|
|
the switch might lose traffic while it's
|
|
changing the switching mode.
|
|
'false' - All the ports in the system will be
|
|
disabled when the last fabric card is removed."
|
|
DEFVAL { true }
|
|
::= { cc6kxbarConfiguration 1 }
|
|
|
|
cc6kxbarBusOnlyModeAllowed OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether bus mode is administratively enabled on
|
|
the device or not."
|
|
::= { cc6kxbarConfiguration 2 }
|
|
|
|
cc6kxbarTruncatedModeAllowed OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether truncated mode is
|
|
administratively enabled on the device or not."
|
|
::= { cc6kxbarConfiguration 3 }
|
|
|
|
cc6kxbarMinFabricPresent OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the minimum number
|
|
of switching fabric capable modules to be present in the
|
|
system, for any switching fabric capable module to be in
|
|
'crossbarmode' indicated by cc6kxbarModuleModeSwitchingMode,
|
|
when cc6kxbarTruncatedModeOper is 'false'."
|
|
::= { cc6kxbarConfiguration 4 }
|
|
|
|
cc6kxbarLcdBannerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cc6kxbarLcdBannerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cc6kxbarLcdBannerTable configures the Lcd banner of the
|
|
fabric module."
|
|
::= { cc6kxbarConfiguration 5 }
|
|
|
|
cc6kxbarLcdBannerEntry OBJECT-TYPE
|
|
SYNTAX Cc6kxbarLcdBannerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in cc6kxbarLcdBannerTable.
|
|
Entries are created by the agent based on the
|
|
size of the lcd banner."
|
|
INDEX { cc6kxbarLcdBannerIndex }
|
|
::= { cc6kxbarLcdBannerTable 1 }
|
|
|
|
Cc6kxbarLcdBannerEntry ::= SEQUENCE {
|
|
cc6kxbarLcdBannerIndex Unsigned32,
|
|
cc6kxbarLcdBannerBanner DisplayString,
|
|
cc6kxbarLcdBannerMaxSize Unsigned32
|
|
}
|
|
|
|
cc6kxbarLcdBannerIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Object which specifies a unique entry in the
|
|
table."
|
|
::= { cc6kxbarLcdBannerEntry 1 }
|
|
|
|
cc6kxbarLcdBannerBanner OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Message that would be displayed on the fabric card LCD.
|
|
The size of cc6kxbarLcdBannerBanner should be less than
|
|
or equal to the cc6kxbarLcdBannerMaxSize value."
|
|
::= { cc6kxbarLcdBannerEntry 2 }
|
|
|
|
cc6kxbarLcdBannerMaxSize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum size of the associated cc6kxbarLcdBannerBanner
|
|
object."
|
|
::= { cc6kxbarLcdBannerEntry 3 }
|
|
|
|
|
|
|
|
cc6kxbarTruncatedModeOper OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the truncated mode is
|
|
operationally enabled on the device or not.
|
|
'true' - With the fabric module present in the system,
|
|
cc6kxbarModuleModeSwitchingMode will be
|
|
'crossbarmode' for all the fabric capable
|
|
modules.
|
|
'false'- With the cc6kxbarMinFabricPresent fabric capable
|
|
modules and the fabric module present in the system,
|
|
cc6kxbarModuleModeSwitchingMode
|
|
will be 'crossbarmode' for fabric capable modules."
|
|
::= { cc6kxbarConfiguration 6 }
|
|
|
|
cc6kxbarDcefOnlyModeAllowed OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the dcef mode is enabled on the standby
|
|
supervisor or not.
|
|
'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true'
|
|
makes the cc6kxbarModuleModeSwitchingMode of
|
|
all the active modules to 'dcefmode'.
|
|
With the active fabric module present in the system,
|
|
with the switch being in stateful switchover mode,
|
|
with all the cards that has no distributed Cisco
|
|
Express forwarding switching support being
|
|
powered down and on some platforms with standby
|
|
supervisor ports being shutdown, changing
|
|
cc6kxbarDcefOnlyModeAllowed to 'true' will make the
|
|
standby supervisor module reloaded and booted up
|
|
as distributed forwarding module.
|
|
'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false'
|
|
makes the cc6kxbarModuleModeSwitchingMode of the
|
|
standby supervisor module to the default value.
|
|
Changing cc6kxbarDcefOnlyModeAllowed to 'false'
|
|
will make the standby supervisor reloaded and booted
|
|
up with the default cc6kxbarModuleModeSwitchingMode."
|
|
::= { cc6kxbarConfiguration 7 }
|
|
|
|
cc6kxbarForceBusMode OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether some affected modules are forced to be in
|
|
'busmode' or not.
|
|
'true' - Setting cc6kxbarForceBusMode to 'true' makes the
|
|
cc6kxbarModuleModeSwitchingMode of all
|
|
the affected modules to 'busmode'. Changing the
|
|
cc6kxbarForceBusMode to 'true' will make all the
|
|
affected modules reloaded and booted up as
|
|
non fabric capable modules.
|
|
'false'- Setting cc6kxbarForceBusMode to 'false' makes the
|
|
cc6kxbarModuleModeSwitchingMode of all the affected
|
|
modules to the default value. Changing
|
|
cc6kxbarForceBusMode to 'false' will make all the
|
|
affected modules reloaded and booted up with the
|
|
default cc6kxbarModuleModeSwitchingMode."
|
|
::= { cc6kxbarConfiguration 8 }
|
|
|
|
cc6kxbarBusOnlyModeOper OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the bus mode is operationally enabled on the
|
|
device or not.
|
|
|
|
'true' - Modules are allowed to run in 'busmode'.
|
|
'false' - None of the modules are allowed to run in 'busmode'
|
|
i.e., All the non-fabric capable modules will
|
|
be powered off. Absence of fabric module results
|
|
in all the fabric capable modules being powered
|
|
off."
|
|
::= { cc6kxbarConfiguration 9 }
|
|
|
|
-- Status objects
|
|
|
|
cc6kxbarFabricActiveSlot OBJECT-TYPE
|
|
SYNTAX ModuleSlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cc6kxbarFabricActiveSlot indicates the slot number of the
|
|
active switching fabric module. A value of zero indicates
|
|
that the active switching fabric module is either powered
|
|
down or not present in the chassis."
|
|
::= { cc6kxbarStatus 1 }
|
|
|
|
cc6kxbarFabricBackupSlot OBJECT-TYPE
|
|
SYNTAX ModuleSlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cc6kxbarFabricBackupSlot indicates the slot number of the
|
|
backup switching fabric module. A value of zero indicates
|
|
that the backup switching fabric module is either powered
|
|
down or not present in the chassis."
|
|
::= { cc6kxbarStatus 2 }
|
|
|
|
cc6kxbarModuleModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cc6kxbarModuleModeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cc6kxbarModuleModeTable indicates the switching mode of each
|
|
module in the system."
|
|
::= { cc6kxbarStatus 3 }
|
|
|
|
cc6kxbarModuleModeEntry OBJECT-TYPE
|
|
SYNTAX Cc6kxbarModuleModeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in cc6kxbarModuleModeTable. The agent creates
|
|
an entry when a non switching fabric module
|
|
is inserted in the chassis.
|
|
The agent destroys an entry when a non switching fabric
|
|
module is power down or reset or removed from the chassis."
|
|
INDEX { cc6kxbarModuleModeModule }
|
|
::= { cc6kxbarModuleModeTable 1 }
|
|
|
|
Cc6kxbarModuleModeEntry ::= SEQUENCE {
|
|
cc6kxbarModuleModeModule ModuleSlotNumber,
|
|
cc6kxbarModuleModeSwitchingMode INTEGER
|
|
}
|
|
|
|
cc6kxbarModuleModeModule OBJECT-TYPE
|
|
SYNTAX ModuleSlotNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The module slot number."
|
|
::= { cc6kxbarModuleModeEntry 1 }
|
|
|
|
cc6kxbarModuleModeSwitchingMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
busmode(1),
|
|
crossbarmode(2),
|
|
dcefmode(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cc6kxbarModuleModeSwitchingMode indicates switching mode
|
|
of the cc6kxbarModuleModeModule.
|
|
'busmode' - Modules in this mode don't use fabric.
|
|
Backplane is used for both lookup and data
|
|
forwarding.
|
|
'crossbarmode' - Modules in this mode use backplane
|
|
for forwarding decision and fabric for data
|
|
forwarding
|
|
'dcefmode' - Modules in this mode use fabric for data
|
|
forwarding and local forwarding is enabled."
|
|
::= { cc6kxbarModuleModeEntry 2 }
|
|
|
|
|
|
|
|
cc6kxbarModuleChannelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cc6kxbarModuleChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cc6kxbarModuleChannelTable shows the operational status
|
|
of fabric channels. This table will be instantiated only when
|
|
cc6kxbarFabricActiveSlot has a valid value other than zero."
|
|
::= { cc6kxbarStatus 4 }
|
|
|
|
cc6kxbarModuleChannelEntry OBJECT-TYPE
|
|
SYNTAX Cc6kxbarModuleChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in cc6kxbarModuleChannelTable."
|
|
INDEX {
|
|
cc6kxbarModuleChannelModule,
|
|
cc6kxbarModuleChannelChannel
|
|
}
|
|
::= { cc6kxbarModuleChannelTable 1 }
|
|
|
|
Cc6kxbarModuleChannelEntry ::= SEQUENCE {
|
|
cc6kxbarModuleChannelModule ModuleSlotNumber,
|
|
cc6kxbarModuleChannelChannel FabricChannelNumber,
|
|
cc6kxbarModuleChannelModStatus ChannelStatus,
|
|
cc6kxbarModuleChannelFabStatus ChannelStatus,
|
|
cc6kxbarModuleChannelSpeed Gauge32
|
|
}
|
|
|
|
cc6kxbarModuleChannelModule OBJECT-TYPE
|
|
SYNTAX ModuleSlotNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The module slot number."
|
|
::= { cc6kxbarModuleChannelEntry 1 }
|
|
|
|
cc6kxbarModuleChannelChannel OBJECT-TYPE
|
|
SYNTAX FabricChannelNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fabric channel number of the cc6kxbarModuleChannelModule."
|
|
::= { cc6kxbarModuleChannelEntry 2 }
|
|
|
|
cc6kxbarModuleChannelModStatus OBJECT-TYPE
|
|
SYNTAX ChannelStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the fabric channel at the
|
|
cc6kxbarModuleChannelModule."
|
|
::= { cc6kxbarModuleChannelEntry 3 }
|
|
|
|
cc6kxbarModuleChannelFabStatus OBJECT-TYPE
|
|
SYNTAX ChannelStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the fabric channel at the
|
|
cc6kxbarFabricActiveSlot."
|
|
::= { cc6kxbarModuleChannelEntry 4 }
|
|
|
|
cc6kxbarModuleChannelSpeed OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The speed in mega bits per second of the
|
|
cc6kxbarModuleChannelChannel for cc6kxbarModuleChannelModule."
|
|
::= { cc6kxbarModuleChannelEntry 5 }
|
|
|
|
|
|
-- Statistics Objects
|
|
|
|
cc6kxbarStatisticsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cc6kxbarStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cc6kxbarStatisticsTable gives the
|
|
fabric channel counters and utilization
|
|
information. This table will be instantiated when
|
|
cc6kxbarFabricActiveSlot has a valid value other than
|
|
zero."
|
|
::= { cc6kxbarStatistics 1 }
|
|
|
|
cc6kxbarStatisticsEntry OBJECT-TYPE
|
|
SYNTAX Cc6kxbarStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in cc6kxbarStatisticsTable."
|
|
INDEX {
|
|
cc6kxbarStatisticsModule,
|
|
cc6kxbarStatisticsChannel
|
|
}
|
|
::= { cc6kxbarStatisticsTable 1 }
|
|
|
|
Cc6kxbarStatisticsEntry ::= SEQUENCE {
|
|
cc6kxbarStatisticsModule ModuleSlotNumber,
|
|
cc6kxbarStatisticsChannel FabricChannelNumber,
|
|
cc6kxbarStatisticsInErrors Counter32,
|
|
cc6kxbarStatisticsOutErrors Counter32,
|
|
cc6kxbarStatisticsOutDropped Counter32,
|
|
cc6kxbarStatisticsInUtil Percent,
|
|
cc6kxbarStatisticsOutUtil Percent,
|
|
cc6kxbarStatisticsPeakInUtil Percent,
|
|
cc6kxbarStatisticsPeakTmInUtil DateAndTime,
|
|
cc6kxbarStatisticsPeakOutUtil Percent,
|
|
cc6kxbarStatisticsPeakTmOutUtil DateAndTime,
|
|
cc6kxbarStatisticsLbusDrops Counter32
|
|
}
|
|
|
|
cc6kxbarStatisticsModule OBJECT-TYPE
|
|
SYNTAX ModuleSlotNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The module slot number."
|
|
::= { cc6kxbarStatisticsEntry 1 }
|
|
|
|
cc6kxbarStatisticsChannel OBJECT-TYPE
|
|
SYNTAX FabricChannelNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fabric channel number associated with the
|
|
cc6kxbarStatisticsModule."
|
|
::= { cc6kxbarStatisticsEntry 2 }
|
|
|
|
cc6kxbarStatisticsInErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of error packets received on
|
|
cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule
|
|
since this entry was last initialized."
|
|
::= { cc6kxbarStatisticsEntry 3 }
|
|
|
|
cc6kxbarStatisticsOutErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of error packets transmitted on
|
|
cc6kxbarStatisticsModule through the
|
|
cc6kxbarStatisticsChannel since this entry was
|
|
last initialized."
|
|
::= { cc6kxbarStatisticsEntry 4 }
|
|
|
|
cc6kxbarStatisticsOutDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of dropped packets transmitted on the
|
|
cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule
|
|
since this entry was last initialized."
|
|
::= { cc6kxbarStatisticsEntry 5 }
|
|
|
|
cc6kxbarStatisticsInUtil OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input utilization of the cc6kxbarStatisticsChannel for
|
|
cc6kxbarStatisticsModule."
|
|
::= { cc6kxbarStatisticsEntry 6 }
|
|
|
|
cc6kxbarStatisticsOutUtil OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Output utilization of the cc6kxbarStatisticsChannel for
|
|
cc6kxbarStatisticsModule."
|
|
::= { cc6kxbarStatisticsEntry 7 }
|
|
|
|
cc6kxbarStatisticsPeakInUtil OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the peak value of cc6kxbarStatisticsInUtil of the
|
|
cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule."
|
|
::= { cc6kxbarStatisticsEntry 8 }
|
|
|
|
cc6kxbarStatisticsPeakTmInUtil OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the time of most recent change in the corresponding
|
|
instance value of cc6kxbarStatisticsPeakInUtil.
|
|
|
|
This object contains value 0x0000010100000000 when the
|
|
corresponding instance value of cc6kxbarStatisticsPeakInUtil
|
|
is '0'."
|
|
::= { cc6kxbarStatisticsEntry 9 }
|
|
|
|
cc6kxbarStatisticsPeakOutUtil OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the peak value of cc6kxbarStatisticsOutUtil of the
|
|
cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule."
|
|
::= { cc6kxbarStatisticsEntry 10 }
|
|
|
|
cc6kxbarStatisticsPeakTmOutUtil OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the time of most recent change in the corresponding
|
|
instance value of cc6kxbarStatisticsPeakOutUtil.
|
|
|
|
This object contains value 0x0000010100000000 when the
|
|
corresponding instance value of cc6kxbarStatisticsPeakOutUtil
|
|
is '0'."
|
|
::= { cc6kxbarStatisticsEntry 11 }
|
|
|
|
cc6kxbarStatisticsLbusDrops OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the number of packets that have been
|
|
deterministically dropped due to the threshold on the local
|
|
bus FIFO, errors and exception conditions."
|
|
::= { cc6kxbarStatisticsEntry 12 }
|
|
|
|
|
|
|
|
cc6kxbarErrorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cc6kxbarErrorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cc6kxbarErrorTable provides the fabric channel error
|
|
information. This table will be instantiated only when
|
|
cc6kxbarFabricActiveSlot has a valid value other than zero."
|
|
::= { cc6kxbarStatistics 2 }
|
|
|
|
cc6kxbarErrorEntry OBJECT-TYPE
|
|
SYNTAX Cc6kxbarErrorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in cc6kxbarErrorTable for a specific fabric channel
|
|
on a specific module."
|
|
INDEX {
|
|
cc6kxbarErrorModule,
|
|
cc6kxbarErrorChannel
|
|
}
|
|
::= { cc6kxbarErrorTable 1 }
|
|
|
|
Cc6kxbarErrorEntry ::= SEQUENCE {
|
|
cc6kxbarErrorModule ModuleSlotNumber,
|
|
cc6kxbarErrorChannel FabricChannelNumber,
|
|
cc6kxbarErrorModuleCrc Gauge32,
|
|
cc6kxbarErrorModuleHbeat Gauge32,
|
|
cc6kxbarErrorModuleSync Gauge32,
|
|
cc6kxbarErrorModuleDDRSync Gauge32,
|
|
cc6kxbarErrorChannelSync Gauge32,
|
|
cc6kxbarErrorChannelBuffer Gauge32,
|
|
cc6kxbarErrorChannelTimeout Gauge32
|
|
}
|
|
|
|
cc6kxbarErrorModule OBJECT-TYPE
|
|
SYNTAX ModuleSlotNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The module slot number."
|
|
::= { cc6kxbarErrorEntry 1 }
|
|
|
|
cc6kxbarErrorChannel OBJECT-TYPE
|
|
SYNTAX FabricChannelNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fabric channel number associated with the
|
|
cc6kxbarErrorModule."
|
|
::= { cc6kxbarErrorEntry 2 }
|
|
|
|
cc6kxbarErrorModuleCrc OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the total number of CRC error packets for the
|
|
cc6kxbarErrorChannel of the cc6kxbarErrorModule."
|
|
::= { cc6kxbarErrorEntry 3 }
|
|
|
|
cc6kxbarErrorModuleHbeat OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the total number of heartbeat misses detected
|
|
for the cc6kxbarErrorChannel of the cc6kxbarErrorModule."
|
|
::= { cc6kxbarErrorEntry 4 }
|
|
|
|
cc6kxbarErrorModuleSync OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the total number of times cc6kxbarErrorModule could
|
|
not sync to the active switching fabric module."
|
|
::= { cc6kxbarErrorEntry 5 }
|
|
|
|
cc6kxbarErrorModuleDDRSync OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the total number of DDR(Double Data Rate) channel
|
|
sync errors for the cc6kxbarErrorChannel of the
|
|
cc6kxbarErrorModule."
|
|
::= { cc6kxbarErrorEntry 6 }
|
|
|
|
cc6kxbarErrorChannelSync OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the total number of sync errors received at
|
|
cc6kxbarErrorChannel."
|
|
::= { cc6kxbarErrorEntry 7 }
|
|
|
|
cc6kxbarErrorChannelBuffer OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the total number of times the memory buffer for
|
|
cc6kxbarErrorChannel of the cc6kxbarErrorModule is full."
|
|
::= { cc6kxbarErrorEntry 8 }
|
|
|
|
cc6kxbarErrorChannelTimeout OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the total number of timeouts for input from
|
|
the cc6kxbarErrorChannel of the cc6kxbarErrorModule."
|
|
::= { cc6kxbarErrorEntry 9 }
|
|
|
|
|
|
|
|
-- Switching Bus Objects
|
|
|
|
cc6kxbarSwBusSwitchingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
stalled(2),
|
|
isolated(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current switching status of the
|
|
switching bus on the system.
|
|
|
|
normal -- the switching bus is under normal
|
|
packet switching operation.
|
|
|
|
stalled -- the switching bus has stopped packet
|
|
switching but is still attached to
|
|
the system, i.e., the switching bus
|
|
is stalled.
|
|
|
|
isolated -- the switching bus has stopped packet
|
|
switching and is detached from
|
|
the system, i.e., the switching bus
|
|
is isolated.
|
|
|
|
The object is only instantiated on systems which
|
|
support switching bus switching detection feature."
|
|
::= { cc6kxbarSwBusObjects 1 }
|
|
|
|
cc6kxbarSwBusFailureDuration OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the failure duration of the switching
|
|
bus since the switching bus has transitioned
|
|
out of the normal(1) state as monitored by
|
|
cc6kxbarSwBusSwitchingStatus. If the object
|
|
value of cc6kxbarSwBusSwitchingStatus is
|
|
normal(1), then the object value of
|
|
cc6kxbarSwBusFailureDuration should be zero.
|
|
|
|
The object is only instantiated on systems which
|
|
support switching bus switching detection feature."
|
|
::= { cc6kxbarSwBusObjects 2 }
|
|
|
|
cc6kxbarSwBusNotifEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether or not the notification
|
|
cc6kxbarSwBusStatusChangeNotif should be generated
|
|
when there is change in the switching status of the
|
|
switching bus as monitored by
|
|
cc6kxbarSwBusSwitchingStatus.
|
|
|
|
The object is only instantiated on systems which
|
|
support switching bus switching detection feature."
|
|
::= { cc6kxbarSwBusObjects 3 }
|
|
|
|
cc6kxbarSwBusUtilization OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the percentage of bandwidth utilization
|
|
of the switching bus."
|
|
::= { cc6kxbarSwBusObjects 4 }
|
|
|
|
cc6kxbarSwBusPeakUtilization OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the peak percentage value of bandwidth
|
|
utilization of the switching bus since the system
|
|
started."
|
|
::= { cc6kxbarSwBusObjects 5 }
|
|
|
|
cc6kxbarSwBusPeakTimeUtil OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the time at which the peak percentage value
|
|
of bandwidth utilization of the switching bus value
|
|
occurred."
|
|
::= { cc6kxbarSwBusObjects 6 }
|
|
|
|
-- Internal Bus Objects
|
|
|
|
cc6kxbarIntBusNotifEnable OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
intBusCRCErrExcd(0),
|
|
intBusCRCErrRcvrd(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the generation of a specified
|
|
notification for internal bus is enabled or not.
|
|
If a bit corresponding to a notification is set to
|
|
1, then that notification can be generated.
|
|
|
|
intBusCRCErrExcd -- the cc6kxbarIntBusCRCErrExcdNotif
|
|
notification.
|
|
|
|
intBusCRCErrRcvrd -- the cc6kxbarIntBusCRCErrRcvrdNotif
|
|
notification."
|
|
::= { cc6kxbarIntBusObjects 1 }
|
|
|
|
cc6kxbarIntBusCRCErrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cc6kxbarIntBusCRCErrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing internal bus CRC error information
|
|
on a list of physical entities (such as modules)."
|
|
::= { cc6kxbarIntBusObjects 2 }
|
|
|
|
cc6kxbarIntBusCRCErrEntry OBJECT-TYPE
|
|
SYNTAX Cc6kxbarIntBusCRCErrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing internal bus CRC error information
|
|
on a physical entity (such as a module)."
|
|
INDEX { entPhysicalIndex }
|
|
::= { cc6kxbarIntBusCRCErrTable 1 }
|
|
|
|
Cc6kxbarIntBusCRCErrEntry ::= SEQUENCE {
|
|
cc6kxbarIntBusCRCErrExcdStatus TruthValue,
|
|
cc6kxbarIntBusCRCErrExcdCount Unsigned32
|
|
}
|
|
|
|
cc6kxbarIntBusCRCErrExcdStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the internal bus CRC error
|
|
on a physical entity is currently exceeding the fatal
|
|
threshold or not."
|
|
::= { cc6kxbarIntBusCRCErrEntry 1 }
|
|
|
|
cc6kxbarIntBusCRCErrExcdCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of times the internal bus CRC
|
|
error on a physical entity has exceeded the fatal
|
|
threshold."
|
|
::= { cc6kxbarIntBusCRCErrEntry 2 }
|
|
|
|
|
|
|
|
-- Flow Control Objects
|
|
|
|
cc6kxbarFlowCtrlNotifEnable OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
busThreshExcd(0)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether the generation of a specified
|
|
notification for flow control feature is enabled or
|
|
not. If a bit corresponding to a notification is set
|
|
to one, then that notification can be generated.
|
|
|
|
busThreshExcd -- the cc6kxbarFlowCtrlBusThrExcdNotif
|
|
notification."
|
|
::= { cc6kxbarFlowCtrlObjects 1 }
|
|
|
|
cc6kxbarFlowCtrlBusFIFOThrMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2),
|
|
auto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the mode configuration of the system bus
|
|
flow control FIFO threshold.
|
|
|
|
off -- the flow control FIFO threshold is set to the
|
|
original value defined by the system.
|
|
|
|
on -- the flow control FIFO threshold is set to the
|
|
lower value defined by the system.
|
|
|
|
auto -- the system starts monitoring the system bus
|
|
flow control FIFO threshold and will change the
|
|
flow control FIFO threshold from the original
|
|
value to the lower value when the system detects
|
|
the first occurrence of the threshold exceeding
|
|
on a physical entity (such as a module) over
|
|
the system allowed limit."
|
|
::= { cc6kxbarFlowCtrlObjects 2 }
|
|
|
|
cc6kxbarFlowCtrlBusFIFOThrValue OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
original(1),
|
|
lower(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current value of the system bus flow
|
|
control FIFO threshold, whether it is the original
|
|
value or the lower value."
|
|
::= { cc6kxbarFlowCtrlObjects 3 }
|
|
|
|
cc6kxbarFlowCtrlBusFIFOTransTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the value of sysUpTime at the time
|
|
that the system bus flow control FIFO threshold
|
|
is transitioned to lower value when the object value
|
|
of cc6kxbarFlowCtrlBusFIFOThrValue is 'lower'. This
|
|
object will take on the value of zero when the object
|
|
value of cc6kxbarFlowCtrlBusFIFOThrValue is
|
|
'original'."
|
|
::= { cc6kxbarFlowCtrlObjects 4 }
|
|
|
|
-- System Capacity Objects
|
|
|
|
cc6kxbarSysCapPfcOperMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
pfc3a(2),
|
|
pfc3b(3),
|
|
pfc3bxl(4),
|
|
pfc3cst1(5),
|
|
pfc3cxlst1(6),
|
|
pfc3c(7),
|
|
pfc3cxl(8),
|
|
pfc4(9),
|
|
pfc4xl(10),
|
|
pfc4xxl(11),
|
|
pfc4lite(12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the operating mode of the policy feature
|
|
card (PFC).
|
|
|
|
unknown -- unknown.
|
|
|
|
pfc3a -- Policy feature card 3A.
|
|
|
|
pfc3b -- Policy feature card 3B.
|
|
|
|
pfc3bxl -- Policy feature card 3B XL.
|
|
|
|
pfc3cst1 -- Policy feature card 3C ST1.
|
|
|
|
pfc3cxlst1 -- Policy feature card 3C XL ST1.
|
|
|
|
pfc3c -- Policy feature card 3C.
|
|
|
|
pfc3cxl -- Policy feature card 3C XL.
|
|
|
|
pfc4 -- Policy feature card 4.
|
|
|
|
pfc4xl -- Policy feature card 4 XL.
|
|
|
|
pfc4xxl -- Policy feature card 4 XXL.
|
|
|
|
pfc4lite -- Policy feature card 4 Lite."
|
|
::= { cc6kxbarSystemCapacityObjects 1 }
|
|
|
|
cc6kxbarSysCapSwitchResTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cc6kxbarSysCapSwitchResEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A cc6kxbarSysCapSwitchResTable entry lists
|
|
the capacity information of the switching
|
|
resources for ENTITY-MIB entPhysicalTable entries
|
|
of manageable components with type entPhysicalClass
|
|
module(9)."
|
|
::= { cc6kxbarSystemCapacityObjects 2 }
|
|
|
|
cc6kxbarSysCapSwitchResEntry OBJECT-TYPE
|
|
SYNTAX Cc6kxbarSysCapSwitchResEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A cc6kxbarSysCapSwitchResEntry entry lists
|
|
the capacity information of the switching
|
|
resources for ENTITY-MIB entPhysicalTable entries
|
|
of manageable components with type entPhysicalClass
|
|
module(9).
|
|
|
|
Entries are created by the agent at the system power-up
|
|
or module insertion.
|
|
|
|
Entries are deleted by the agent upon module removal."
|
|
INDEX { entPhysicalIndex }
|
|
::= { cc6kxbarSysCapSwitchResTable 1 }
|
|
|
|
Cc6kxbarSysCapSwitchResEntry ::= SEQUENCE {
|
|
cc6kxbarSysCapSwitchResSeries INTEGER,
|
|
cc6kxbarSysCapSwitchResCefMode INTEGER
|
|
}
|
|
|
|
cc6kxbarSysCapSwitchResSeries OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
supervisor(2),
|
|
classic(3),
|
|
fabric(4),
|
|
dcef720(5),
|
|
cef720(6),
|
|
dcef256(7),
|
|
cef256(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the module series for traffic forwarding options.
|
|
|
|
unknown -- unknown.
|
|
|
|
supervisor -- supervisor module.
|
|
|
|
classic -- classic module.
|
|
|
|
fabric -- fabric module.
|
|
|
|
dcef720 -- dCEF720 module.
|
|
|
|
cef720 -- CEF720 module.
|
|
|
|
dcef256 -- dCEF256 module.
|
|
|
|
cef256 -- CEF256 module."
|
|
::= { cc6kxbarSysCapSwitchResEntry 1 }
|
|
|
|
cc6kxbarSysCapSwitchResCefMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
dcef(2),
|
|
cef(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the Cisco Express Forwarding (CEF) mode of
|
|
the module.
|
|
|
|
notApplicable -- not applicable for this module.
|
|
|
|
dcef -- distributed CEF.
|
|
|
|
cef -- CEF."
|
|
::= { cc6kxbarSysCapSwitchResEntry 2 }
|
|
|
|
|
|
|
|
-- Fabric Error Recovery Objects
|
|
|
|
cc6kxbarErrRcvryThreshLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the threshold on fabric link errors occurring
|
|
in a channel for the fabric error recovery feature."
|
|
::= { cc6kxbarErrorRecoveryObjects 1 }
|
|
|
|
cc6kxbarErrRcvryThreshPersLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the threshold on persistent fabric link errors
|
|
occurring in a channel for the fabric error recovery feature."
|
|
::= { cc6kxbarErrorRecoveryObjects 2 }
|
|
|
|
cc6kxbarErrRcvrySwitchoverEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether the switchover to the standby fabric module
|
|
is enabled or not on the detection of excessive fabric link
|
|
errors occurring in a channel for the fabric error recovery
|
|
feature."
|
|
::= { cc6kxbarErrorRecoveryObjects 3 }
|
|
|
|
cc6kxbarErrRcvryPersLinkResync OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether the system will resync the channel or not
|
|
on the detection of excessive persistent fabric link errors
|
|
in a channel for the fabric error recovery feature."
|
|
::= { cc6kxbarErrorRecoveryObjects 4 }
|
|
|
|
cc6kxbarErrRcvryChResyncCount OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the consecutive number of times of
|
|
channel resync within the time interval as specified
|
|
by cc6kxbarErrRcvryChResyncInterval, over which
|
|
the channel resync is considered as failure
|
|
for the fabric error recovery feature."
|
|
::= { cc6kxbarErrorRecoveryObjects 5 }
|
|
|
|
cc6kxbarErrRcvryChResyncInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the time interval for the consecutive
|
|
counting of channel resync for the fabric error
|
|
recovery feature."
|
|
::= { cc6kxbarErrorRecoveryObjects 6 }
|
|
|
|
-- Traffic Monitor Objects
|
|
|
|
cc6kxbarTMSwBusUtilEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether the traffic monitor feature is
|
|
enabled on the switching bus or not."
|
|
::= { cc6kxbarTrafficMonitorSwBusObjects 1 }
|
|
|
|
cc6kxbarTMSwBusUtilInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the interval at the end of which
|
|
the switching bus traffic utilization is compared
|
|
against cc6kxbarTMSwBusUtilThreshold."
|
|
::= { cc6kxbarTrafficMonitorSwBusObjects 2 }
|
|
|
|
cc6kxbarTMSwBusUtilThreshold OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the threshold of the switching bus
|
|
traffic utilization."
|
|
::= { cc6kxbarTrafficMonitorSwBusObjects 3 }
|
|
|
|
cc6kxbarTMSwBusUtilLogCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of times the following
|
|
events are logged for the switching bus:
|
|
|
|
1. the switching bus traffic utilization has
|
|
risen above the configured threshold (as
|
|
specified by cc6kxbarTMSwBusUtilThreshold),
|
|
or has kept staying above the configured
|
|
threshold at a logging interval (as specified
|
|
by cc6kxbarTMSwBusUtilLogInterval).
|
|
|
|
2. the switching bus traffic utilization
|
|
has fallen below the configured threshold."
|
|
::= { cc6kxbarTrafficMonitorSwBusObjects 4 }
|
|
|
|
cc6kxbarTMSwBusUtilLastLogTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the last logging time of the
|
|
events as counted in cc6kxbarTMSwBusUtilLogCount.
|
|
|
|
This object will contain 0-1-1,00:00:00.0 when
|
|
the value of cc6kxbarTMSwBusUtilLogCount is zero."
|
|
::= { cc6kxbarTrafficMonitorSwBusObjects 5 }
|
|
|
|
cc6kxbarTMSwBusUtilLogInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the logging interval if the switching
|
|
bus traffic utilization keeps staying above the
|
|
cc6kxbarTMSwBusUtilThreshold."
|
|
::= { cc6kxbarTrafficMonitorSwBusObjects 6 }
|
|
|
|
cc6kxbarTMSwBusUtilUtilization OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The switching bus traffic utilization included
|
|
in the notification currently being sent."
|
|
::= { cc6kxbarTrafficMonitorSwBusObjects 7 }
|
|
|
|
cc6kxbarTMSwBusUtilNotifEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether the generation of
|
|
c6kxbarTMSwBusUtilAboveNotif and
|
|
c6kxbarTMSwBusUtilBelowNotif notifications
|
|
is enabled or not.
|
|
|
|
When this object is 'true', the generation of
|
|
cc6kxbarTMSwBusUtilAboveNotif and
|
|
c6kxbarTMSwBusUtilBelowNotif notifications is
|
|
enabled. When this object is 'false', the
|
|
generation of cc6kxbarTMSwBusUtilAboveNotif and
|
|
c6kxbarTMSwBusUtilBelowNotif notifications
|
|
is disabled."
|
|
::= { cc6kxbarTrafficMonitorSwBusObjects 8 }
|
|
|
|
cc6kxbarTMChUtilTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cc6kxbarTMChUtilEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cc6kxbarTrafficMntrChUtilTable provides the
|
|
information on the traffic utilization of each
|
|
fabric channel associated with each module slot
|
|
for a given traffic direction in the chassis."
|
|
::= { cc6kxbarTrafficMonitorChObjects 1 }
|
|
|
|
cc6kxbarTMChUtilEntry OBJECT-TYPE
|
|
SYNTAX Cc6kxbarTMChUtilEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in cc6kxbarTMChUtilTable. Each traffic
|
|
direction for each fabric channel associated with
|
|
each module slot in the chassis will have an
|
|
entry in this table."
|
|
INDEX {
|
|
cc6kxbarTMChUtilModule,
|
|
cc6kxbarTMChUtilChannel,
|
|
cc6kxbarTMChUtilDirection
|
|
}
|
|
::= { cc6kxbarTMChUtilTable 1 }
|
|
|
|
Cc6kxbarTMChUtilEntry ::= SEQUENCE {
|
|
cc6kxbarTMChUtilModule ModuleSlotNumber,
|
|
cc6kxbarTMChUtilChannel FabricChannelNumber,
|
|
cc6kxbarTMChUtilDirection INTEGER,
|
|
cc6kxbarTMChUtilEnable TruthValue,
|
|
cc6kxbarTMChUtilInterval Unsigned32,
|
|
cc6kxbarTMChUtilThreshold Percent,
|
|
cc6kxbarTMChUtilLogCount Counter32,
|
|
cc6kxbarTMChUtilLastLogTime DateAndTime
|
|
}
|
|
|
|
cc6kxbarTMChUtilModule OBJECT-TYPE
|
|
SYNTAX ModuleSlotNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the module slot number in the chassis."
|
|
::= { cc6kxbarTMChUtilEntry 1 }
|
|
|
|
cc6kxbarTMChUtilChannel OBJECT-TYPE
|
|
SYNTAX FabricChannelNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the fabric channel number associated with
|
|
the corresponding cc6kxbarTMChUtilModule."
|
|
::= { cc6kxbarTMChUtilEntry 2 }
|
|
|
|
cc6kxbarTMChUtilDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ingress(1),
|
|
egress(2)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the direction of traffic to be monitored."
|
|
::= { cc6kxbarTMChUtilEntry 3 }
|
|
|
|
cc6kxbarTMChUtilEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether the traffic monitor feature is
|
|
enabled on a fabric channel for a given traffic
|
|
direction or not."
|
|
::= { cc6kxbarTMChUtilEntry 4 }
|
|
|
|
cc6kxbarTMChUtilInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the interval at the end of which the
|
|
traffic utilization on a fabric channel for a
|
|
given traffic direction is compared against
|
|
its corresponding cc6kxbarTMChUtilThreshold."
|
|
::= { cc6kxbarTMChUtilEntry 5 }
|
|
|
|
cc6kxbarTMChUtilThreshold OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the threshold of the traffic utilization
|
|
on a fabric channel for a given traffic direction."
|
|
::= { cc6kxbarTMChUtilEntry 6 }
|
|
|
|
cc6kxbarTMChUtilLogCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of times the following
|
|
events are logged on a fabric channel
|
|
for a given direction.
|
|
|
|
1. the traffic utilization on a fabric channel
|
|
for a given traffic direction has risen above its
|
|
corresponding configured threshold (as specified
|
|
by cc6kxbarTMChUtilThreshold), or has kept
|
|
staying above the configured threshold at a
|
|
logging interval (as specified by
|
|
cc6kxbarTMChUtilLogInterval).
|
|
|
|
2. the traffic utilization on a fabric channel
|
|
for a given traffic direction has fallen below
|
|
its corresponding configured threshold."
|
|
::= { cc6kxbarTMChUtilEntry 7 }
|
|
|
|
cc6kxbarTMChUtilLastLogTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the last logging time of the
|
|
events as counted in the corresponding
|
|
cc6kxbarTMChUtilLogCount on a fabric channel
|
|
for a given traffic direction.
|
|
|
|
This object will contain 0-1-1,00:00:00.0 when
|
|
the corresponding cc6kxbarTMChUtilLogCount is zero."
|
|
::= { cc6kxbarTMChUtilEntry 8 }
|
|
|
|
|
|
|
|
cc6kxbarTMChUtilLogInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the logging interval if the traffic
|
|
utilization for a fabric channel on a given
|
|
traffic direction keeps staying above its
|
|
corresponding cc6kxbarTMChUtilThreshold."
|
|
::= { cc6kxbarTrafficMonitorChObjects 2 }
|
|
|
|
cc6kxbarTMChUtilUtilization OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The traffic utilization on a fabric channel
|
|
for a given traffic direction included in the
|
|
notification currently being sent."
|
|
::= { cc6kxbarTrafficMonitorChObjects 3 }
|
|
|
|
cc6kxbarTMChUtilNotifEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether the generation of
|
|
cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif
|
|
notifications is enabled or not.
|
|
|
|
When this object is 'true', the generation of
|
|
cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif
|
|
notifications is enabled. When this object is 'false',
|
|
the generation of cc6kxbarTMChUtilAboveNotif and
|
|
cc6kxbarTMChUtilBelowNotif notifications is disabled."
|
|
::= { cc6kxbarTrafficMonitorChObjects 4 }
|
|
-- Notifications
|
|
|
|
ciscoCat6kXbarMIBNotifs OBJECT IDENTIFIER
|
|
::= { ciscoCat6kCrossbarMIB 0 }
|
|
|
|
|
|
cc6kxbarSwBusStatusChangeNotif NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cc6kxbarSwBusSwitchingStatus,
|
|
cc6kxbarSwBusFailureDuration
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A cc6kxbarSwBusStatusChangeNotif notification
|
|
is sent by the device when there is change
|
|
in switching status of the switching bus as
|
|
monitored by cc6kxbarSwBusSwitchingStatus."
|
|
::= { ciscoCat6kXbarMIBNotifs 1 }
|
|
|
|
cc6kxbarIntBusCRCErrExcdNotif NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
entPhysicalName,
|
|
entPhysicalVendorType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A cc6kxbarIntBusCRCThreshExcdNotif notification
|
|
is sent by the system when the system has
|
|
detected that the internal bus CRC error on
|
|
a physical entity (such as a module) as specified
|
|
by entPhysicalName has exceeded the fatal threshold."
|
|
::= { ciscoCat6kXbarMIBNotifs 2 }
|
|
|
|
cc6kxbarIntBusCRCErrRcvrdNotif NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
entPhysicalName,
|
|
entPhysicalVendorType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A cc6kxbarIntBusCRCErrRcvrdNotif notification
|
|
is sent by the system when the system has
|
|
recovered as the internal bus CRC error on
|
|
a physical entity (such as a module) as
|
|
specified by entPhysicalName has fallen below
|
|
the normal threshold."
|
|
::= { ciscoCat6kXbarMIBNotifs 3 }
|
|
|
|
cc6kxbarFlowCtrlBusThrExcdNotif NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
entPhysicalName,
|
|
entPhysicalVendorType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A cc6kxbarFlowCtrlBusThrExcdNotif notification
|
|
is sent by the system when the system detects the
|
|
first occurrence of the system bus flow control FIFO
|
|
threshold exceeding on a physical entity
|
|
(such as a module) over the system allowed limit
|
|
when the object value of
|
|
cc6kxbarFlowCtrlBusFIFOThrMode is 'auto'."
|
|
::= { ciscoCat6kXbarMIBNotifs 4 }
|
|
|
|
cc6kxbarTMSwBusUtilAboveNotif NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cc6kxbarTMSwBusUtilUtilization,
|
|
cc6kxbarTMSwBusUtilThreshold,
|
|
cc6kxbarTMSwBusUtilInterval,
|
|
entPhysicalDescr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when the switching bus
|
|
traffic utilization has risen above the configured
|
|
threshold (as specified by
|
|
cc6kxbarTMSwBusUtilThreshold), or has kept staying
|
|
above the configured threshold at a logging interval
|
|
(as specified by cc6kxbarTMSwBusUtilLogInterval).
|
|
The varbind entPhysicalDescr specifies the physical
|
|
entity (such as chassis) for which the
|
|
cc6kxbarTMSwBusUtilAboveNotif is sent."
|
|
::= { ciscoCat6kXbarMIBNotifs 5 }
|
|
|
|
cc6kxbarTMSwBusUtilBelowNotif NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cc6kxbarTMSwBusUtilUtilization,
|
|
cc6kxbarTMSwBusUtilThreshold,
|
|
cc6kxbarTMSwBusUtilInterval,
|
|
entPhysicalDescr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when the switching bus
|
|
traffic utilization has fallen below the configured
|
|
threshold (as specified by
|
|
cc6kxbarTMSwBusUtilThreshold). The varbind
|
|
entPhysicalDescr specifies the physical entity
|
|
(such as chassis) for which the
|
|
cc6kxbarTMSwBusUtilBelowNotif is sent."
|
|
::= { ciscoCat6kXbarMIBNotifs 6 }
|
|
|
|
cc6kxbarTMChUtilAboveNotif NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cc6kxbarTMChUtilUtilization,
|
|
cc6kxbarTMChUtilThreshold,
|
|
cc6kxbarTMChUtilInterval,
|
|
entPhysicalDescr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when the traffic
|
|
utilization on a fabric channel for a given
|
|
traffic direction has risen above its
|
|
corresponding configured threshold (as
|
|
specified by cc6kxbarTMChUtilThreshold), or has
|
|
kept staying above the configured threshold at a
|
|
logging interval (as specified by
|
|
cc6kxbarTMChUtilLogInterval). The varbind
|
|
entPhysicalDescr specifies the physical entity
|
|
(such as chassis) for which the
|
|
cc6kxbarTMChUtilAboveNotif is sent."
|
|
::= { ciscoCat6kXbarMIBNotifs 7 }
|
|
|
|
cc6kxbarTMChUtilBelowNotif NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cc6kxbarTMChUtilUtilization,
|
|
cc6kxbarTMChUtilThreshold,
|
|
cc6kxbarTMChUtilInterval,
|
|
entPhysicalDescr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when the traffic
|
|
utilization on a fabric channel for a given
|
|
traffic direction has fallen below its
|
|
corresponding configured threshold (as
|
|
specified by cc6kxbarTMChUtilThreshold). The
|
|
varbind entPhysicalDescr specifies the
|
|
physical entity (such as chassis) for which
|
|
the cc6kxbarTMChUtilBelowNotif is sent."
|
|
::= { ciscoCat6kXbarMIBNotifs 8 }
|
|
-- Conformance and Compliance
|
|
|
|
cc6kxbarMIBConformance OBJECT IDENTIFIER
|
|
::= { ciscoCat6kCrossbarMIB 3 }
|
|
|
|
cc6kxbarMIBCompliances OBJECT IDENTIFIER
|
|
::= { cc6kxbarMIBConformance 1 }
|
|
|
|
cc6kxbarMIBGroups OBJECT IDENTIFIER
|
|
::= { cc6kxbarMIBConformance 2 }
|
|
|
|
|
|
-- Conformance
|
|
|
|
cc6kxbarMIBCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for
|
|
the CISCO-CAT6K-CROSSBAR-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cc6kxbarModuleStatusGroup,
|
|
cc6kxbarChannelStatusGroup,
|
|
cc6kxbarChannelStatisticsGroup
|
|
}
|
|
|
|
GROUP cc6kxbarFallbackGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fallback mode feature."
|
|
|
|
GROUP cc6kxbarBusOnlyAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support busonly mode feature."
|
|
::= { cc6kxbarMIBCompliances 2 }
|
|
|
|
cc6kxbarMIBComplianceVer1 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for
|
|
the CISCO-CAT6K-CROSSBAR-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cc6kxbarModuleStatusGroupVer1,
|
|
cc6kxbarChannelStatusGroup,
|
|
cc6kxbarChannelStatisticsGroupVer1
|
|
}
|
|
|
|
GROUP cc6kxbarFallbackGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fallback mode feature."
|
|
|
|
GROUP cc6kxbarBusOnlyAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support bus only mode feature."
|
|
|
|
GROUP cc6kxbarLcdBannerGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support lcd banner feature."
|
|
|
|
GROUP cc6kxbarChannelUtilGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support Input and Output traffic utilization on the
|
|
fabric channel."
|
|
|
|
GROUP cc6kxbarChannelSpeedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fabric channel speed feature."
|
|
|
|
GROUP cc6kxbarSwBusGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection feature."
|
|
|
|
GROUP cc6kxbarSwBusNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection notification
|
|
feature."
|
|
::= { cc6kxbarMIBCompliances 3 }
|
|
|
|
cc6kxbarMIBComplianceVer2 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for
|
|
the CISCO-CAT6K-CROSSBAR-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cc6kxbarModuleStatusGroupVer1,
|
|
cc6kxbarChannelStatusGroup,
|
|
cc6kxbarChannelStatisticsGroupVer1
|
|
}
|
|
|
|
GROUP cc6kxbarFallbackGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fallback mode feature."
|
|
|
|
GROUP cc6kxbarBusOnlyAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support bus only mode feature."
|
|
|
|
GROUP cc6kxbarLcdBannerGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support lcd banner feature."
|
|
|
|
GROUP cc6kxbarChannelUtilGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support Input and Output traffic utilization on the
|
|
fabric channel."
|
|
|
|
GROUP cc6kxbarChannelSpeedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fabric channel speed feature."
|
|
|
|
GROUP cc6kxbarSwBusGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection feature."
|
|
|
|
GROUP cc6kxbarSwBusNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection notification
|
|
feature."
|
|
|
|
GROUP cc6kxbarTruncatedOperGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
operational truncated mode."
|
|
::= { cc6kxbarMIBCompliances 4 }
|
|
|
|
cc6kxbarMIBComplianceVer3 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for
|
|
the CISCO-CAT6K-CROSSBAR-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cc6kxbarModuleStatusGroupVer1,
|
|
cc6kxbarChannelStatusGroup,
|
|
cc6kxbarChannelStatisticsGroupVer1
|
|
}
|
|
|
|
GROUP cc6kxbarFallbackGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fallback mode feature."
|
|
|
|
GROUP cc6kxbarBusOnlyAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support bus only mode feature."
|
|
|
|
GROUP cc6kxbarLcdBannerGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support lcd banner feature."
|
|
|
|
GROUP cc6kxbarChannelUtilGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support Input and Output traffic utilization on the
|
|
fabric channel."
|
|
|
|
GROUP cc6kxbarChannelSpeedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fabric channel speed feature."
|
|
|
|
GROUP cc6kxbarSwBusGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection feature."
|
|
|
|
GROUP cc6kxbarSwBusNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection notification
|
|
feature."
|
|
|
|
GROUP cc6kxbarTruncatedOperGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
operational truncated mode."
|
|
|
|
GROUP cc6kxbarIntBusNotifControlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus notifications."
|
|
|
|
GROUP cc6kxbarIntBusCRCErrNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus CRC error notifications."
|
|
::= { cc6kxbarMIBCompliances 5 }
|
|
|
|
cc6kxbarMIBComplianceVer4 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for
|
|
the CISCO-CAT6K-CROSSBAR-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cc6kxbarModuleStatusGroupVer1,
|
|
cc6kxbarChannelStatusGroup,
|
|
cc6kxbarChannelStatisticsGroupVer1
|
|
}
|
|
|
|
GROUP cc6kxbarFallbackGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fallback mode feature."
|
|
|
|
GROUP cc6kxbarBusOnlyAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support bus only mode feature."
|
|
|
|
GROUP cc6kxbarLcdBannerGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support lcd banner feature."
|
|
|
|
GROUP cc6kxbarChannelUtilGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support Input and Output traffic utilization on the
|
|
fabric channel."
|
|
|
|
GROUP cc6kxbarChannelSpeedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fabric channel speed feature."
|
|
|
|
GROUP cc6kxbarSwBusGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection feature."
|
|
|
|
GROUP cc6kxbarSwBusNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection notification
|
|
feature."
|
|
|
|
GROUP cc6kxbarTruncatedOperGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
operational truncated mode."
|
|
|
|
GROUP cc6kxbarIntBusNotifControlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus notifications."
|
|
|
|
GROUP cc6kxbarIntBusCRCErrNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus CRC error notifications."
|
|
|
|
GROUP cc6kxbarIntBusCRCErrGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus CRC error status."
|
|
::= { cc6kxbarMIBCompliances 6 }
|
|
|
|
cc6kxbarMIBComplianceVer5 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for
|
|
the CISCO-CAT6K-CROSSBAR-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cc6kxbarModuleStatusGroupVer1,
|
|
cc6kxbarChannelStatusGroup,
|
|
cc6kxbarChannelStatisticsGroupVer1
|
|
}
|
|
|
|
GROUP cc6kxbarFallbackGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fallback mode feature."
|
|
|
|
GROUP cc6kxbarBusOnlyAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support bus only mode feature."
|
|
|
|
GROUP cc6kxbarLcdBannerGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support lcd banner feature."
|
|
|
|
GROUP cc6kxbarChannelUtilGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support Input and Output traffic utilization on the
|
|
fabric channel."
|
|
|
|
GROUP cc6kxbarChannelSpeedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fabric channel speed feature."
|
|
|
|
GROUP cc6kxbarSwBusGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection feature."
|
|
|
|
GROUP cc6kxbarSwBusNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection notification
|
|
feature."
|
|
|
|
GROUP cc6kxbarTruncatedOperGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
operational truncated mode."
|
|
|
|
GROUP cc6kxbarIntBusNotifControlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus notifications."
|
|
|
|
GROUP cc6kxbarIntBusCRCErrNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus CRC error notifications."
|
|
|
|
GROUP cc6kxbarIntBusCRCErrGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus CRC error status."
|
|
|
|
GROUP cc6kxbarDcefOnlyModeAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
dcef only mode feature."
|
|
|
|
GROUP cc6kxbarForceBusModeGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
force bus mode feature."
|
|
|
|
GROUP cc6kxbarFlowCtrlNotifCtrlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
the system flow control notification control."
|
|
|
|
GROUP cc6kxbarFlowCtrlBusThreshGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
the system bus flow control FIFO threshold configuration."
|
|
|
|
GROUP cc6kxbarFlowCtrlBusThrNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
the system bus flow control FIFO threshold exceeding
|
|
notification."
|
|
|
|
GROUP cc6kxbarBusOnlyModeOperGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
operational bus mode."
|
|
::= { cc6kxbarMIBCompliances 7 }
|
|
|
|
cc6kxbarMIBComplianceVer6 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for
|
|
the CISCO-CAT6K-CROSSBAR-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cc6kxbarModuleStatusGroupVer1,
|
|
cc6kxbarChannelStatusGroup,
|
|
cc6kxbarChannelStatisticsGroupVer1
|
|
}
|
|
|
|
GROUP cc6kxbarFallbackGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fallback mode feature."
|
|
|
|
GROUP cc6kxbarBusOnlyAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support bus only mode feature."
|
|
|
|
GROUP cc6kxbarLcdBannerGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support lcd banner feature."
|
|
|
|
GROUP cc6kxbarChannelUtilGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support Input and Output traffic utilization on the
|
|
fabric channel."
|
|
|
|
GROUP cc6kxbarChannelSpeedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fabric channel speed feature."
|
|
|
|
GROUP cc6kxbarSwBusGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection feature."
|
|
|
|
GROUP cc6kxbarSwBusNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection notification
|
|
feature."
|
|
|
|
GROUP cc6kxbarTruncatedOperGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
operational truncated mode."
|
|
|
|
GROUP cc6kxbarIntBusNotifControlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus notifications."
|
|
|
|
GROUP cc6kxbarIntBusCRCErrNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus CRC error notifications."
|
|
|
|
GROUP cc6kxbarIntBusCRCErrGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus CRC error status."
|
|
|
|
GROUP cc6kxbarDcefOnlyModeAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
dcef only mode feature."
|
|
|
|
GROUP cc6kxbarForceBusModeGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
force bus mode feature."
|
|
|
|
GROUP cc6kxbarFlowCtrlNotifCtrlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
the system flow control notification control."
|
|
|
|
GROUP cc6kxbarFlowCtrlBusThreshGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
the system bus flow control FIFO threshold configuration."
|
|
|
|
GROUP cc6kxbarFlowCtrlBusThrNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
the system bus flow control FIFO threshold exceeding
|
|
notification."
|
|
|
|
GROUP cc6kxbarBusOnlyModeOperGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
operational bus mode."
|
|
|
|
GROUP cc6kxbarSysCapPfcOperModeGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which
|
|
support the system information of PFC operational mode."
|
|
|
|
GROUP cc6kxbarSysCapSwitchResGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which
|
|
support the capacity information of switching
|
|
resources in the system."
|
|
|
|
GROUP cc6kxbarChannelUtilGroup1
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support peak input and output traffic utilization on the
|
|
fabric channel."
|
|
|
|
GROUP cc6kxbarSwBusGroup1
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus utilization."
|
|
|
|
GROUP cc6kxbarErrorGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support error statistics on the fabric channel."
|
|
|
|
GROUP cc6kxbarErrRcvryThresholdGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration of thresholds on fabric link errors
|
|
for the fabric error recovery feature."
|
|
|
|
GROUP cc6kxbarErrRcvrySwitchoverGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration of fabric switchover on excessive fabric
|
|
link errors for the fabric error recovery feature."
|
|
::= { cc6kxbarMIBCompliances 8 }
|
|
|
|
cc6kxbarMIBComplianceVer7 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for
|
|
the CISCO-CAT6K-CROSSBAR-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cc6kxbarModuleStatusGroupVer1,
|
|
cc6kxbarChannelStatusGroup,
|
|
cc6kxbarChannelStatisticsGroupVer1
|
|
}
|
|
|
|
GROUP cc6kxbarFallbackGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fallback mode feature."
|
|
|
|
GROUP cc6kxbarBusOnlyAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support bus only mode feature."
|
|
|
|
GROUP cc6kxbarLcdBannerGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support lcd banner feature."
|
|
|
|
GROUP cc6kxbarChannelUtilGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support Input and Output traffic utilization on the
|
|
fabric channel."
|
|
|
|
GROUP cc6kxbarChannelSpeedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fabric channel speed feature."
|
|
|
|
GROUP cc6kxbarSwBusGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection feature."
|
|
|
|
GROUP cc6kxbarSwBusNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection notification
|
|
feature."
|
|
|
|
GROUP cc6kxbarTruncatedOperGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
operational truncated mode."
|
|
|
|
GROUP cc6kxbarIntBusNotifControlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus notifications."
|
|
|
|
GROUP cc6kxbarIntBusCRCErrNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus CRC error notifications."
|
|
|
|
GROUP cc6kxbarIntBusCRCErrGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus CRC error status."
|
|
|
|
GROUP cc6kxbarDcefOnlyModeAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
dcef only mode feature."
|
|
|
|
GROUP cc6kxbarForceBusModeGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
force bus mode feature."
|
|
|
|
GROUP cc6kxbarFlowCtrlNotifCtrlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
the system flow control notification control."
|
|
|
|
GROUP cc6kxbarFlowCtrlBusThreshGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
the system bus flow control FIFO threshold configuration."
|
|
|
|
GROUP cc6kxbarFlowCtrlBusThrNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
the system bus flow control FIFO threshold exceeding
|
|
notification."
|
|
|
|
GROUP cc6kxbarBusOnlyModeOperGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
operational bus mode."
|
|
|
|
GROUP cc6kxbarSysCapPfcOperModeGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which
|
|
support the system information of PFC operational mode."
|
|
|
|
GROUP cc6kxbarSysCapSwitchResGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which
|
|
support the capacity information of switching
|
|
resources in the system."
|
|
|
|
GROUP cc6kxbarChannelUtilGroup1
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support peak input and output traffic utilization on the
|
|
fabric channel."
|
|
|
|
GROUP cc6kxbarSwBusGroup1
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus utilization."
|
|
|
|
GROUP cc6kxbarErrorGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support error statistics on the fabric channel."
|
|
|
|
GROUP cc6kxbarErrRcvryThresholdGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration of thresholds on fabric link errors
|
|
for the fabric error recovery feature."
|
|
|
|
GROUP cc6kxbarErrRcvrySwitchoverGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration of fabric switchover on excessive fabric
|
|
link errors for the fabric error recovery feature."
|
|
|
|
GROUP cc6kxbarErrRcvryPersLinkResGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration of channel resync on excessive
|
|
persistent fabric link errors for the fabric error
|
|
recovery feature."
|
|
|
|
GROUP cc6kxbarErrRcvryChResyncGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration of channel resync threshold for the
|
|
fabric error recovery feature."
|
|
|
|
GROUP cc6kxbarTMSwBusUtilGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration for traffic monitor feature on the
|
|
switching bus."
|
|
|
|
GROUP cc6kxbarTMSwBusUtilNotifControlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the notification control for traffic monitor
|
|
notifications on the switching bus."
|
|
|
|
GROUP cc6kxbarTMSwBusUtilNotifObjectGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which support
|
|
traffic monitor notifications on the switching bus."
|
|
|
|
GROUP cc6kxbarTMSwBusUtilNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which support
|
|
traffic monitor notifications on the switching bus."
|
|
|
|
GROUP cc6kxbarTMChUtilGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration for traffic monitor feature on
|
|
fabric channels."
|
|
|
|
GROUP cc6kxbarTMChUtilNotifControlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the notification control for traffic monitor
|
|
notifications on fabric channels."
|
|
|
|
GROUP cc6kxbarTMChUtilNotifObjectGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which support
|
|
traffic monitor notifications on fabric channels."
|
|
|
|
GROUP cc6kxbarTMChUtilNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which support
|
|
traffic monitor notifications on fabric channels."
|
|
::= { cc6kxbarMIBCompliances 9 }
|
|
|
|
cc6kxbarMIBComplianceVer8 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for
|
|
the CISCO-CAT6K-CROSSBAR-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
cc6kxbarModuleStatusGroupVer1,
|
|
cc6kxbarChannelStatusGroup,
|
|
cc6kxbarChannelStatisticsGroupVer1
|
|
}
|
|
|
|
GROUP cc6kxbarFallbackGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fallback mode feature."
|
|
|
|
GROUP cc6kxbarBusOnlyAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support bus only mode feature."
|
|
|
|
GROUP cc6kxbarLcdBannerGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support lcd banner feature."
|
|
|
|
GROUP cc6kxbarChannelUtilGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support Input and Output traffic utilization on the
|
|
fabric channel."
|
|
|
|
GROUP cc6kxbarChannelSpeedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support fabric channel speed feature."
|
|
|
|
GROUP cc6kxbarSwBusGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection feature."
|
|
|
|
GROUP cc6kxbarSwBusNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus switching detection notification
|
|
feature."
|
|
|
|
GROUP cc6kxbarTruncatedOperGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
operational truncated mode."
|
|
|
|
GROUP cc6kxbarIntBusNotifControlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus notifications."
|
|
|
|
GROUP cc6kxbarIntBusCRCErrNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus CRC error notifications."
|
|
|
|
GROUP cc6kxbarIntBusCRCErrGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
internal bus CRC error status."
|
|
|
|
GROUP cc6kxbarDcefOnlyModeAllowedGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
dcef only mode feature."
|
|
|
|
GROUP cc6kxbarForceBusModeGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
force bus mode feature."
|
|
|
|
GROUP cc6kxbarFlowCtrlNotifCtrlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
the system flow control notification control."
|
|
|
|
GROUP cc6kxbarFlowCtrlBusThreshGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
the system bus flow control FIFO threshold configuration."
|
|
|
|
GROUP cc6kxbarFlowCtrlBusThrNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
the system bus flow control FIFO threshold exceeding
|
|
notification."
|
|
|
|
GROUP cc6kxbarBusOnlyModeOperGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
operational bus mode."
|
|
|
|
GROUP cc6kxbarSysCapPfcOperModeGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which
|
|
support the system information of PFC operational mode."
|
|
|
|
GROUP cc6kxbarSysCapSwitchResGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which
|
|
support the capacity information of switching
|
|
resources in the system."
|
|
|
|
GROUP cc6kxbarChannelUtilGroup1
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support peak input and output traffic utilization on the
|
|
fabric channel."
|
|
|
|
GROUP cc6kxbarSwBusGroup1
|
|
DESCRIPTION
|
|
"This group is mandatory only for platforms which support
|
|
switching bus utilization."
|
|
|
|
GROUP cc6kxbarErrorGroup
|
|
DESCRIPTION
|
|
"This group is mandatory only for those platforms which
|
|
support error statistics on the fabric channel."
|
|
|
|
GROUP cc6kxbarErrRcvryThresholdGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration of thresholds on fabric link errors
|
|
for the fabric error recovery feature."
|
|
|
|
GROUP cc6kxbarErrRcvrySwitchoverGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration of fabric switchover on excessive fabric
|
|
link errors for the fabric error recovery feature."
|
|
|
|
GROUP cc6kxbarErrRcvryPersLinkResGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration of channel resync on excessive
|
|
persistent fabric link errors for the fabric error
|
|
recovery feature."
|
|
|
|
GROUP cc6kxbarErrRcvryChResyncGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration of channel resync threshold for the
|
|
fabric error recovery feature."
|
|
|
|
GROUP cc6kxbarTMSwBusUtilGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration for traffic monitor feature on the
|
|
switching bus."
|
|
|
|
GROUP cc6kxbarTMSwBusUtilNotifControlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the notification control for traffic monitor
|
|
notifications on the switching bus."
|
|
|
|
GROUP cc6kxbarTMSwBusUtilNotifObjectGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which support
|
|
traffic monitor notifications on the switching bus."
|
|
|
|
GROUP cc6kxbarTMSwBusUtilNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which support
|
|
traffic monitor notifications on the switching bus."
|
|
|
|
GROUP cc6kxbarTMChUtilGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the configuration for traffic monitor feature on
|
|
fabric channels."
|
|
|
|
GROUP cc6kxbarTMChUtilNotifControlGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which provide
|
|
the notification control for traffic monitor
|
|
notifications on fabric channels."
|
|
|
|
GROUP cc6kxbarTMChUtilNotifObjectGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which support
|
|
traffic monitor notifications on fabric channels."
|
|
|
|
GROUP cc6kxbarTMChUtilNotifGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which support
|
|
traffic monitor notifications on fabric channels."
|
|
|
|
GROUP cc6kxbarStatisticsLbusDropGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for platforms which support
|
|
local bus packet drop statistics on fabric channels."
|
|
::= { cc6kxbarMIBCompliances 10 }
|
|
|
|
-- Units of Conformance
|
|
|
|
cc6kxbarModuleStatusGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarLcdBannerMaxSize,
|
|
cc6kxbarLcdBannerBanner,
|
|
cc6kxbarTruncatedModeAllowed,
|
|
cc6kxbarMinFabricPresent,
|
|
cc6kxbarFabricActiveSlot,
|
|
cc6kxbarFabricBackupSlot,
|
|
cc6kxbarModuleModeSwitchingMode
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects providing
|
|
configuration and operation of the crossbar
|
|
switching fabric module and switching capable
|
|
module.
|
|
cc6kxbarModuleStatusGroup object is superseded by cc6kxbarModuleStatusGroupVer1."
|
|
::= { cc6kxbarMIBGroups 1 }
|
|
|
|
cc6kxbarChannelStatusGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarModuleChannelModStatus,
|
|
cc6kxbarModuleChannelFabStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing
|
|
status and configuration of the fabric channel."
|
|
::= { cc6kxbarMIBGroups 2 }
|
|
|
|
cc6kxbarChannelStatisticsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarStatisticsInErrors,
|
|
cc6kxbarStatisticsOutErrors,
|
|
cc6kxbarStatisticsOutDropped,
|
|
cc6kxbarStatisticsInUtil,
|
|
cc6kxbarStatisticsOutUtil
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects providing statistics for
|
|
the fabric channel.
|
|
cc6kxbarChannelStatisticsGroup object is superseded by cc6kxbarChannelStatisticsGroupVer1."
|
|
::= { cc6kxbarMIBGroups 3 }
|
|
|
|
cc6kxbarFallbackGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarFallbackMode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls system fallback to bus-mode
|
|
after loss of switching fabric module."
|
|
::= { cc6kxbarMIBGroups 4 }
|
|
|
|
cc6kxbarBusOnlyAllowedGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarBusOnlyModeAllowed }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the value of
|
|
cc6kxbarModuleModeSwitchingMode of each module."
|
|
::= { cc6kxbarMIBGroups 5 }
|
|
|
|
cc6kxbarModuleStatusGroupVer1 OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarTruncatedModeAllowed,
|
|
cc6kxbarMinFabricPresent,
|
|
cc6kxbarFabricActiveSlot,
|
|
cc6kxbarFabricBackupSlot,
|
|
cc6kxbarModuleModeSwitchingMode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing
|
|
configuration and operation of the crossbar
|
|
switching fabric module and switching capable
|
|
module."
|
|
::= { cc6kxbarMIBGroups 6 }
|
|
|
|
cc6kxbarChannelStatisticsGroupVer1 OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarStatisticsInErrors,
|
|
cc6kxbarStatisticsOutErrors,
|
|
cc6kxbarStatisticsOutDropped
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing statistics for
|
|
the fabric channel."
|
|
::= { cc6kxbarMIBGroups 7 }
|
|
|
|
cc6kxbarLcdBannerGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarLcdBannerMaxSize,
|
|
cc6kxbarLcdBannerBanner
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing configuration of
|
|
the lcd Banner of the fabric module."
|
|
::= { cc6kxbarMIBGroups 8 }
|
|
|
|
cc6kxbarChannelUtilGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarStatisticsInUtil,
|
|
cc6kxbarStatisticsOutUtil
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These object determines Input and Output Utilization of the
|
|
fabric channel."
|
|
::= { cc6kxbarMIBGroups 9 }
|
|
|
|
cc6kxbarChannelSpeedGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarModuleChannelSpeed }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the
|
|
speed of the fabric channel."
|
|
::= { cc6kxbarMIBGroups 10 }
|
|
|
|
cc6kxbarSwBusGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarSwBusSwitchingStatus,
|
|
cc6kxbarSwBusFailureDuration,
|
|
cc6kxbarSwBusNotifEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects for the switching bus switching
|
|
detection feature."
|
|
::= { cc6kxbarMIBGroups 11 }
|
|
|
|
cc6kxbarSwBusNotifGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { cc6kxbarSwBusStatusChangeNotif }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of notifications for the switching
|
|
bus switching detection feature."
|
|
::= { cc6kxbarMIBGroups 12 }
|
|
|
|
cc6kxbarTruncatedOperGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarTruncatedModeOper }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the
|
|
operational truncated mode."
|
|
::= { cc6kxbarMIBGroups 13 }
|
|
|
|
cc6kxbarIntBusNotifControlGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarIntBusNotifEnable }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects to control the notification
|
|
generation for internal bus."
|
|
::= { cc6kxbarMIBGroups 14 }
|
|
|
|
cc6kxbarIntBusCRCErrNotifGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
cc6kxbarIntBusCRCErrExcdNotif,
|
|
cc6kxbarIntBusCRCErrRcvrdNotif
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of notifications for the
|
|
internal bus CRC error."
|
|
::= { cc6kxbarMIBGroups 15 }
|
|
|
|
cc6kxbarIntBusCRCErrGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarIntBusCRCErrExcdStatus,
|
|
cc6kxbarIntBusCRCErrExcdCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects to indicate the internal bus
|
|
CRC error information on a physical entity."
|
|
::= { cc6kxbarMIBGroups 16 }
|
|
|
|
cc6kxbarDcefOnlyModeAllowedGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarDcefOnlyModeAllowed }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the configuration
|
|
and information about the dcef only mode feature."
|
|
::= { cc6kxbarMIBGroups 17 }
|
|
|
|
cc6kxbarForceBusModeGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarForceBusMode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the configuration
|
|
and information about the force bus mode feature."
|
|
::= { cc6kxbarMIBGroups 18 }
|
|
|
|
cc6kxbarFlowCtrlNotifCtrlGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarFlowCtrlNotifEnable }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects to control the notification
|
|
generation for the system flow control feature."
|
|
::= { cc6kxbarMIBGroups 19 }
|
|
|
|
cc6kxbarFlowCtrlBusThreshGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarFlowCtrlBusFIFOThrMode,
|
|
cc6kxbarFlowCtrlBusFIFOThrValue,
|
|
cc6kxbarFlowCtrlBusFIFOTransTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing configuration
|
|
information about the system bus flow control FIFO
|
|
threshold."
|
|
::= { cc6kxbarMIBGroups 20 }
|
|
|
|
cc6kxbarFlowCtrlBusThrNotifGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { cc6kxbarFlowCtrlBusThrExcdNotif }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of notifications for the system bus
|
|
flow control FIFO threshold exceeding."
|
|
::= { cc6kxbarMIBGroups 21 }
|
|
|
|
cc6kxbarBusOnlyModeOperGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarBusOnlyModeOper }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the
|
|
operational bus mode."
|
|
::= { cc6kxbarMIBGroups 22 }
|
|
|
|
cc6kxbarSysCapPfcOperModeGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarSysCapPfcOperMode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the system
|
|
information of PFC operational mode."
|
|
::= { cc6kxbarMIBGroups 23 }
|
|
|
|
cc6kxbarSysCapSwitchResGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarSysCapSwitchResSeries,
|
|
cc6kxbarSysCapSwitchResCefMode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the capacity
|
|
information of switching resources in the system."
|
|
::= { cc6kxbarMIBGroups 24 }
|
|
|
|
cc6kxbarChannelUtilGroup1 OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarStatisticsPeakInUtil,
|
|
cc6kxbarStatisticsPeakTmInUtil,
|
|
cc6kxbarStatisticsPeakOutUtil,
|
|
cc6kxbarStatisticsPeakTmOutUtil
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the information about peak
|
|
input and output utilization of a specific fabric channel on
|
|
a specific module."
|
|
::= { cc6kxbarMIBGroups 25 }
|
|
|
|
cc6kxbarSwBusGroup1 OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarSwBusUtilization,
|
|
cc6kxbarSwBusPeakUtilization,
|
|
cc6kxbarSwBusPeakTimeUtil
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the information about
|
|
switching bus utilization."
|
|
::= { cc6kxbarMIBGroups 26 }
|
|
|
|
cc6kxbarErrorGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarErrorModuleCrc,
|
|
cc6kxbarErrorModuleHbeat,
|
|
cc6kxbarErrorModuleSync,
|
|
cc6kxbarErrorModuleDDRSync,
|
|
cc6kxbarErrorChannelSync,
|
|
cc6kxbarErrorChannelBuffer,
|
|
cc6kxbarErrorChannelTimeout
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing error statistics for
|
|
a specific fabric channel on a specific module."
|
|
::= { cc6kxbarMIBGroups 27 }
|
|
|
|
cc6kxbarErrRcvryThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarErrRcvryThreshLink,
|
|
cc6kxbarErrRcvryThreshPersLink
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the configuration
|
|
of thresholds on fabric link errors for the fabric
|
|
error recovery feature."
|
|
::= { cc6kxbarMIBGroups 28 }
|
|
|
|
cc6kxbarErrRcvrySwitchoverGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarErrRcvrySwitchoverEnable }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the configuration
|
|
of fabric switchover on excessive fabric link errors
|
|
for the fabric error recovery feature."
|
|
::= { cc6kxbarMIBGroups 29 }
|
|
|
|
cc6kxbarErrRcvryPersLinkResGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarErrRcvryPersLinkResync }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the configuration
|
|
of channel resync on excessive persistent fabric link
|
|
errors for the fabric error recovery feature."
|
|
::= { cc6kxbarMIBGroups 30 }
|
|
|
|
cc6kxbarErrRcvryChResyncGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarErrRcvryChResyncCount,
|
|
cc6kxbarErrRcvryChResyncInterval
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the configuration
|
|
for channel resync threshold for the fabric error
|
|
recovery feature."
|
|
::= { cc6kxbarMIBGroups 31 }
|
|
|
|
cc6kxbarTMSwBusUtilGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarTMSwBusUtilEnable,
|
|
cc6kxbarTMSwBusUtilInterval,
|
|
cc6kxbarTMSwBusUtilThreshold,
|
|
cc6kxbarTMSwBusUtilLogCount,
|
|
cc6kxbarTMSwBusUtilLastLogTime,
|
|
cc6kxbarTMSwBusUtilLogInterval
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing configuration
|
|
information for traffic monitor feature on
|
|
the switching bus."
|
|
::= { cc6kxbarMIBGroups 32 }
|
|
|
|
cc6kxbarTMSwBusUtilNotifControlGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarTMSwBusUtilNotifEnable }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects to control the traffic monitor
|
|
notification generation on the switching bus."
|
|
::= { cc6kxbarMIBGroups 33 }
|
|
|
|
cc6kxbarTMSwBusUtilNotifObjectGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarTMSwBusUtilUtilization }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects included in the traffic monitor
|
|
notifications on the switching bus."
|
|
::= { cc6kxbarMIBGroups 34 }
|
|
|
|
cc6kxbarTMSwBusUtilNotifGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
cc6kxbarTMSwBusUtilAboveNotif,
|
|
cc6kxbarTMSwBusUtilBelowNotif
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of traffic monitor notifications on the
|
|
switching bus."
|
|
::= { cc6kxbarMIBGroups 35 }
|
|
|
|
cc6kxbarTMChUtilGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cc6kxbarTMChUtilEnable,
|
|
cc6kxbarTMChUtilInterval,
|
|
cc6kxbarTMChUtilThreshold,
|
|
cc6kxbarTMChUtilLogCount,
|
|
cc6kxbarTMChUtilLastLogTime,
|
|
cc6kxbarTMChUtilLogInterval
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the configuration
|
|
information for traffic monitor feature on fabric
|
|
channels."
|
|
::= { cc6kxbarMIBGroups 36 }
|
|
|
|
cc6kxbarTMChUtilNotifControlGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarTMChUtilNotifEnable }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects to control the traffic monitor
|
|
notification generation on fabric channels."
|
|
::= { cc6kxbarMIBGroups 37 }
|
|
|
|
cc6kxbarTMChUtilNotifObjectGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarTMChUtilUtilization }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects included in the traffic monitor
|
|
notifications on fabric channels."
|
|
::= { cc6kxbarMIBGroups 38 }
|
|
|
|
cc6kxbarTMChUtilNotifGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
cc6kxbarTMChUtilAboveNotif,
|
|
cc6kxbarTMChUtilBelowNotif
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of traffic monitor notifications on
|
|
fabric channels."
|
|
::= { cc6kxbarMIBGroups 39 }
|
|
|
|
cc6kxbarStatisticsLbusDropGroup OBJECT-GROUP
|
|
OBJECTS { cc6kxbarStatisticsLbusDrops }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information for
|
|
local bus drop packets statistics."
|
|
::= { cc6kxbarMIBGroups 40 }
|
|
|
|
END
|
|
|
|
|
|
|