-- CISCO-ENTITY-SENSOR-MIB
|
|
--
|
|
-- November 1997, Cliff L. Sojourner
|
|
--
|
|
-- Copyright (c) 1998-2003-2006, 2013, 2015 by cisco Systems Inc.
|
|
-- All rights reserved.
|
|
-- *****************************************************************
|
|
|
|
CISCO-ENTITY-SENSOR-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
Integer32
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP,
|
|
NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION,
|
|
TimeStamp,
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
entPhysicalIndex
|
|
FROM ENTITY-MIB
|
|
EntPhysicalIndexOrZero
|
|
FROM CISCO-TC
|
|
ciscoMgmt
|
|
FROM CISCO-SMI;
|
|
|
|
|
|
ciscoEntitySensorMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201501150000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
"Postal: Cisco Systems, Inc.
|
|
170 West Tasman Drive
|
|
San Jose, CA 95134-1706
|
|
USA
|
|
|
|
Tel: +1 408 526 4000
|
|
|
|
E-mail: cs-snmp@cisco.com"
|
|
DESCRIPTION
|
|
"The CISCO-ENTITY-SENSOR-MIB is used to monitor
|
|
the values of sensors in the Entity-MIB (RFC 2037)
|
|
entPhysicalTable."
|
|
REVISION "201501150000Z"
|
|
DESCRIPTION
|
|
"Corrected the definition of entSensorPrecision."
|
|
REVISION "201309210000Z"
|
|
DESCRIPTION
|
|
"Added entSensorThresholdRecoveryNotification to
|
|
entitySensorMIBNotifications.
|
|
Added entSensorThresholdSeverity as a varbind
|
|
object to entSensorThresholdNotification.
|
|
Added entitySensorNotificationGroup
|
|
and deprecated
|
|
entitySensorThresholdNotificationGroup.
|
|
Added entSensorThresholdNotification and
|
|
entSensorThresholdRecoveryNotification to
|
|
entitySensorNotificationGroup.
|
|
Added entitySensorMIBComplianceV05 and
|
|
deprecated entitySensorMIBComplianceV04."
|
|
REVISION "200711120000Z"
|
|
DESCRIPTION
|
|
"Added entitySensorNotifCtrlGlobalGroup."
|
|
REVISION "200601010000Z"
|
|
DESCRIPTION
|
|
"Add new object entSensorMeasuredEntity to
|
|
entSensorValueTable."
|
|
REVISION "200509080000Z"
|
|
DESCRIPTION
|
|
"Change the module descriptor name from entitySensorMIB
|
|
to ciscoEntitySensorMIB since ENTITY-SENSOR-MIB also
|
|
uses the same name and there is a conflict."
|
|
REVISION "200301070000Z"
|
|
DESCRIPTION
|
|
"[1] Add dBm(14) in SensorDataType."
|
|
REVISION "200210160000Z"
|
|
DESCRIPTION
|
|
"[1] Add critical(30) in CSensorThresholdSeverity.
|
|
[2] Change to MAX-ACCESS read-write for 3 objects.
|
|
[3] Add entitySensorMIBComplianceV02."
|
|
REVISION "200006200000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { ciscoMgmt 91 }
|
|
|
|
|
|
entitySensorMIBObjects OBJECT IDENTIFIER
|
|
::= { ciscoEntitySensorMIB 1 }
|
|
|
|
entitySensorMIBNotificationPrefix OBJECT IDENTIFIER
|
|
::= { ciscoEntitySensorMIB 2 }
|
|
|
|
entitySensorMIBConformance OBJECT IDENTIFIER
|
|
::= { ciscoEntitySensorMIB 3 }
|
|
|
|
|
|
-- textual conventions
|
|
|
|
SensorDataType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor measurement data types. valid values are:
|
|
other(1): a measure other than those listed below
|
|
unknown(2): unknown measurement, or
|
|
arbitrary, relative numbers
|
|
voltsAC(3): electric potential
|
|
voltsDC(4): electric potential
|
|
amperes(5): electric current
|
|
watts(6): power
|
|
hertz(7): frequency
|
|
celsius(8): temperature
|
|
percentRH(9): percent relative humidity
|
|
rpm(10): shaft revolutions per minute
|
|
cmm(11),: cubic meters per minute (airflow)
|
|
truthvalue(12): value takes { true(1), false(2) }
|
|
specialEnum(13): value takes user defined enumerated values
|
|
dBm(14): dB relative to 1mW of power"
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
unknown(2),
|
|
voltsAC(3),
|
|
voltsDC(4),
|
|
amperes(5),
|
|
watts(6),
|
|
hertz(7),
|
|
celsius(8),
|
|
percentRH(9),
|
|
rpm(10),
|
|
cmm(11),
|
|
truthvalue(12),
|
|
specialEnum(13),
|
|
dBm(14)
|
|
}
|
|
|
|
SensorDataScale ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"International System of Units (SI) prefixes."
|
|
SYNTAX INTEGER {
|
|
yocto(1), -- 10^-24
|
|
zepto(2), -- 10^-21
|
|
atto(3), -- 10^-18
|
|
femto(4), -- 10^-15
|
|
pico(5), -- 10^-12
|
|
nano(6), -- 10^-9
|
|
micro(7), -- 10^-6
|
|
milli(8), -- 10^-3
|
|
units(9), -- 10^0
|
|
kilo(10), -- 10^3
|
|
mega(11), -- 10^6
|
|
giga(12), -- 10^9
|
|
tera(13), -- 10^12
|
|
exa(14), -- 10^15
|
|
peta(15), -- 10^18
|
|
zetta(16), -- 10^21
|
|
yotta(17) -- 10^24
|
|
}
|
|
|
|
SensorPrecision ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When in the range 1 to 9, SensorPrecision is the number
|
|
of decimal places in the fractional part of
|
|
a SensorValue fixed-point number. When in the range -8 to
|
|
-1, SensorPrecision is the number of accurate digits in
|
|
a SensorValue fixed-point number.
|
|
|
|
SensorPrecision is 0 for non-fixed-point numbers.
|
|
|
|
Agent implementors must choose a value for SensorPrecision
|
|
so that the precision and accuracy of a SensorValue is
|
|
correctly indicated.
|
|
|
|
For example, a temperature sensor that can measure 0o to
|
|
100o C in 0.1o increments, +/- 0.05o, would have a
|
|
SensorPrecision of 1, a SensorDataScale of units(0), and a
|
|
SensorValue ranging from 0 to 1000.
|
|
The SensorValue would be interpreted as (degrees C * 10).
|
|
|
|
If that temperature sensor's precision were 0.1o but its
|
|
accuracy were only +/- 0.5o, then the SensorPrecision would
|
|
be 0. The SensorValue would be interpreted as degrees C.
|
|
|
|
Another example: a fan rotation speed sensor that measures RPM
|
|
from 0 to 10,000 in 100 RPM increments, with an accuracy of
|
|
+50/-37 RPM, would have a SensorPrecision of -2, a
|
|
SensorDataScale of units(9), and a SensorValue ranging from 0
|
|
to 10000. The 10s and 1s digits of SensorValue would always
|
|
be 0."
|
|
SYNTAX INTEGER (-8..9)
|
|
|
|
SensorValue ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For sensors that measure voltsAC, voltsDC,
|
|
amperes, watts, hertz, celsius, cmm
|
|
this item is a fixed point number ranging from
|
|
-999,999,999 to +999,999,999. Use the value
|
|
-1000000000 to indicate underflow. Use the value
|
|
+1000000000 to indicate overflow. Use SensorPrecision
|
|
to indicate how many fractional digits the SensorValue
|
|
has.
|
|
|
|
|
|
For sensors that measure percentRH, this item
|
|
is a number ranging from 0 to 100.
|
|
|
|
For sensors that measure rpm, this item
|
|
can take only nonnegative values, 0..999999999.
|
|
|
|
For sensors of type truthvalue, this item
|
|
can take only two values: true(1), false(2).
|
|
|
|
For sensors of type specialEnum, this item
|
|
can take any value in the range (-1000000000..1000000000),
|
|
but the meaning of each value is specific to the
|
|
sensor.
|
|
|
|
For sensors of type other and unknown,
|
|
this item can take any value in the range
|
|
(-1000000000..1000000000), but the meaning of the values
|
|
are specific to the sensor.
|
|
|
|
Use Entity-MIB entPhysicalTable.entPhysicalVendorType
|
|
to learn about the sensor type."
|
|
SYNTAX INTEGER (-1000000000..1000000000)
|
|
|
|
SensorStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the operational status of the sensor.
|
|
|
|
ok(1) means the agent can read the sensor
|
|
value.
|
|
|
|
unavailable(2) means that the agent presently
|
|
can not report the sensor value.
|
|
|
|
nonoperational(3) means that the agent believes
|
|
the sensor is broken. The sensor could have a
|
|
hard failure (disconnected wire), or a soft failure
|
|
such as out-of-range, jittery, or wildly fluctuating
|
|
readings."
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
unavailable(2),
|
|
nonoperational(3)
|
|
}
|
|
|
|
SensorValueUpdateRate ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the interval in seconds between updates to the
|
|
sensor's value.
|
|
|
|
The value zero indicates:
|
|
- the sensor value is updated on demand (when polled by the
|
|
agent for a get-request),
|
|
- or when the sensor value changes (event-driven),
|
|
- or the agent does not know the rate"
|
|
SYNTAX INTEGER (0..999999999)
|
|
|
|
SensorThresholdSeverity ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor threshold severity. Valid values are:
|
|
|
|
other(1) : a severity other than those listed below.
|
|
minor(10) : Minor Problem threshold.
|
|
major(20) : Major Problem threshold.
|
|
critical(30): Critical problem threshold. A system might shut
|
|
down the sensor associated FRU automatically if
|
|
the sensor value reach the critical problem
|
|
threshold."
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
minor(10),
|
|
major(20),
|
|
critical(30)
|
|
}
|
|
|
|
SensorThresholdRelation ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor threshold relational operator types. valid values are:
|
|
|
|
lessThan(1): if the sensor value is less than
|
|
the threshold value
|
|
lessOrEqual(2): if the sensor value is less than or equal to
|
|
the threshold value
|
|
greaterThan(3): if the sensor value is greater than
|
|
the threshold value
|
|
greaterOrEqual(4): if the sensor value is greater than or equal
|
|
to the threshold value
|
|
equalTo(5): if the sensor value is equal to
|
|
the threshold value
|
|
notEqualTo(6): if the sensor value is not equal to
|
|
the threshold value"
|
|
SYNTAX INTEGER {
|
|
lessThan(1),
|
|
lessOrEqual(2),
|
|
greaterThan(3),
|
|
greaterOrEqual(4),
|
|
equalTo(5),
|
|
notEqualTo(6)
|
|
}
|
|
-- MIB variables
|
|
|
|
entSensorValues OBJECT IDENTIFIER
|
|
::= { entitySensorMIBObjects 1 }
|
|
|
|
entSensorThresholds OBJECT IDENTIFIER
|
|
::= { entitySensorMIBObjects 2 }
|
|
|
|
entSensorGlobalObjects OBJECT IDENTIFIER
|
|
::= { entitySensorMIBObjects 3 }
|
|
|
|
-- entSensorValueTable
|
|
|
|
entSensorValueTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EntSensorValueEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table lists the type, scale, and present value
|
|
of a sensor listed in the Entity-MIB entPhysicalTable."
|
|
::= { entSensorValues 1 }
|
|
|
|
entSensorValueEntry OBJECT-TYPE
|
|
SYNTAX EntSensorValueEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entSensorValueTable entry describes the
|
|
present reading of a sensor, the measurement units
|
|
and scale, and sensor operational status."
|
|
INDEX { entPhysicalIndex }
|
|
::= { entSensorValueTable 1 }
|
|
|
|
EntSensorValueEntry ::= SEQUENCE {
|
|
entSensorType SensorDataType,
|
|
entSensorScale SensorDataScale,
|
|
entSensorPrecision SensorPrecision,
|
|
entSensorValue SensorValue,
|
|
entSensorStatus SensorStatus,
|
|
entSensorValueTimeStamp TimeStamp,
|
|
entSensorValueUpdateRate SensorValueUpdateRate,
|
|
entSensorMeasuredEntity EntPhysicalIndexOrZero
|
|
}
|
|
|
|
entSensorType OBJECT-TYPE
|
|
SYNTAX SensorDataType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the type of data
|
|
reported by the entSensorValue.
|
|
|
|
This variable is set by the agent at start-up
|
|
and the value does not change during operation."
|
|
::= { entSensorValueEntry 1 }
|
|
|
|
entSensorScale OBJECT-TYPE
|
|
SYNTAX SensorDataScale
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the exponent to apply
|
|
to sensor values reported by entSensorValue.
|
|
|
|
This variable is set by the agent at start-up
|
|
and the value does not change during operation."
|
|
::= { entSensorValueEntry 2 }
|
|
|
|
entSensorPrecision OBJECT-TYPE
|
|
SYNTAX SensorPrecision
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the number of decimal
|
|
places of precision in fixed-point
|
|
sensor values reported by entSensorValue.
|
|
|
|
This variable is set to 0 when entSensorType
|
|
is not a fixed-point type: e.g.'percentRH(9)',
|
|
'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.
|
|
|
|
This variable is set by the agent at start-up
|
|
and the value does not change during operation."
|
|
::= { entSensorValueEntry 3 }
|
|
|
|
entSensorValue OBJECT-TYPE
|
|
SYNTAX SensorValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable reports the most recent measurement seen
|
|
by the sensor.
|
|
|
|
To correctly display or interpret this variable's value,
|
|
you must also know entSensorType, entSensorScale, and
|
|
entSensorPrecision.
|
|
|
|
However, you can compare entSensorValue with the threshold
|
|
values given in entSensorThresholdTable without any semantic
|
|
knowledge."
|
|
::= { entSensorValueEntry 4 }
|
|
|
|
entSensorStatus OBJECT-TYPE
|
|
SYNTAX SensorStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the present operational status
|
|
of the sensor."
|
|
::= { entSensorValueEntry 5 }
|
|
|
|
entSensorValueTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the age of the value reported by
|
|
entSensorValue"
|
|
::= { entSensorValueEntry 6 }
|
|
|
|
entSensorValueUpdateRate OBJECT-TYPE
|
|
SYNTAX SensorValueUpdateRate
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the rate that the agent
|
|
updates entSensorValue."
|
|
::= { entSensorValueEntry 7 }
|
|
|
|
entSensorMeasuredEntity OBJECT-TYPE
|
|
SYNTAX EntPhysicalIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the physical entity for which the
|
|
sensor is taking measurements. For example, for a sensor
|
|
measuring the voltage output of a power-supply, this object
|
|
would be the entPhysicalIndex of that power-supply; for a sensor
|
|
measuring the temperature inside one chassis of a multi-chassis
|
|
system, this object would be the enPhysicalIndex of that
|
|
chassis.
|
|
|
|
This object has a value of zero when the physical entity
|
|
for which the sensor is taking measurements can not be
|
|
represented by any one row in the entPhysicalTable, or that
|
|
there is no such physical entity."
|
|
::= { entSensorValueEntry 8 }
|
|
|
|
|
|
-- entSensorThresholdTable
|
|
|
|
entSensorThresholdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EntSensorThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table lists the threshold severity, relation, and
|
|
comparison value, for a sensor listed in the Entity-MIB
|
|
entPhysicalTable."
|
|
::= { entSensorThresholds 1 }
|
|
|
|
entSensorThresholdEntry OBJECT-TYPE
|
|
SYNTAX EntSensorThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entSensorThresholdTable entry describes the
|
|
thresholds for a sensor: the threshold severity,
|
|
the threshold value, the relation, and the
|
|
evaluation of the threshold.
|
|
|
|
Only entities of type sensor(8) are listed in this table.
|
|
Only pre-configured thresholds are listed in this table.
|
|
|
|
Users can create sensor-value monitoring instruments
|
|
in different ways, such as RMON alarms, Expression-MIB, etc.
|
|
|
|
Entries are created by the agent at system startup and
|
|
FRU insertion. Entries are deleted by the agent at
|
|
FRU removal."
|
|
INDEX {
|
|
entPhysicalIndex,
|
|
entSensorThresholdIndex
|
|
}
|
|
::= { entSensorThresholdTable 1 }
|
|
|
|
EntSensorThresholdEntry ::= SEQUENCE {
|
|
entSensorThresholdIndex Integer32,
|
|
entSensorThresholdSeverity SensorThresholdSeverity,
|
|
entSensorThresholdRelation SensorThresholdRelation,
|
|
entSensorThresholdValue SensorValue,
|
|
entSensorThresholdEvaluation TruthValue,
|
|
entSensorThresholdNotificationEnable TruthValue
|
|
}
|
|
|
|
entSensorThresholdIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..99999999)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely identifies an entry
|
|
in the entSensorThresholdTable. This index
|
|
permits the same sensor to have several
|
|
different thresholds."
|
|
::= { entSensorThresholdEntry 1 }
|
|
|
|
entSensorThresholdSeverity OBJECT-TYPE
|
|
SYNTAX SensorThresholdSeverity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the severity of this threshold."
|
|
::= { entSensorThresholdEntry 2 }
|
|
|
|
entSensorThresholdRelation OBJECT-TYPE
|
|
SYNTAX SensorThresholdRelation
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the relation between sensor value
|
|
(entSensorValue) and threshold value (entSensorThresholdValue),
|
|
required to trigger the alarm. when evaluating the relation,
|
|
entSensorValue is on the left of entSensorThresholdRelation,
|
|
entSensorThresholdValue is on the right.
|
|
|
|
in pseudo-code, the evaluation-alarm mechanism is:
|
|
|
|
...
|
|
if (entSensorStatus == ok) then
|
|
if (evaluate(entSensorValue, entSensorThresholdRelation,
|
|
entSensorThresholdValue))
|
|
then
|
|
if (entSensorThresholdNotificationEnable == true))
|
|
then
|
|
raise_alarm(sensor's entPhysicalIndex);
|
|
endif
|
|
endif
|
|
endif
|
|
..."
|
|
::= { entSensorThresholdEntry 3 }
|
|
|
|
entSensorThresholdValue OBJECT-TYPE
|
|
SYNTAX SensorValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the value of the threshold.
|
|
|
|
To correctly display or interpret this variable's value,
|
|
you must also know entSensorType, entSensorScale, and
|
|
entSensorPrecision.
|
|
|
|
However, you can directly compare entSensorValue
|
|
with the threshold values given in entSensorThresholdTable
|
|
without any semantic knowledge."
|
|
::= { entSensorThresholdEntry 4 }
|
|
|
|
entSensorThresholdEvaluation OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the result of the most
|
|
recent evaluation of the threshold. If the threshold
|
|
condition is true, entSensorThresholdEvaluation
|
|
is true(1). If the threshold condition is false,
|
|
entSensorThresholdEvaluation is false(2).
|
|
|
|
Thresholds are evaluated at the rate indicated by
|
|
entSensorValueUpdateRate."
|
|
::= { entSensorThresholdEntry 5 }
|
|
|
|
entSensorThresholdNotificationEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable controls generation of
|
|
entSensorThresholdNotification for this threshold.
|
|
|
|
When this variable is 'true', generation of
|
|
entSensorThresholdNotification is enabled for this
|
|
threshold. When this variable is 'false',
|
|
generation of entSensorThresholdNotification is
|
|
disabled for this threshold."
|
|
::= { entSensorThresholdEntry 6 }
|
|
|
|
|
|
|
|
-- Entity Sensor Global Objects
|
|
|
|
entSensorThreshNotifGlobalEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable enables the generation of
|
|
entSensorThresholdNotification globally
|
|
on the device. If this object value is
|
|
'false', then no entSensorThresholdNotification
|
|
will be generated on this device. If this object
|
|
value is 'true', then whether a
|
|
entSensorThresholdNotification for a threshold will
|
|
be generated or not depends on the instance value of
|
|
entSensorThresholdNotificationEnable for that
|
|
threshold."
|
|
::= { entSensorGlobalObjects 1 }
|
|
-- notifications
|
|
|
|
entitySensorMIBNotifications OBJECT IDENTIFIER
|
|
::= { entitySensorMIBNotificationPrefix 0 }
|
|
|
|
|
|
entSensorThresholdNotification NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
entSensorThresholdValue,
|
|
entSensorValue,
|
|
entSensorThresholdSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notification is generated when
|
|
the sensor value entSensorValue crosses
|
|
the threshold value entSensorThresholdValue and
|
|
the value of entSensorThreshNotifGlobalEnable is true.
|
|
|
|
entSensorThresholdSeverity indicates the severity
|
|
of this threshold.
|
|
|
|
The agent implementation guarantees prompt, timely
|
|
evaluation of threshold and generation of this
|
|
notification."
|
|
::= { entitySensorMIBNotifications 1 }
|
|
|
|
entSensorThresholdRecoveryNotification NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
entSensorValue,
|
|
entSensorThresholdSeverity,
|
|
entSensorThresholdValue
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is generated
|
|
as a recovery notification when
|
|
the sensor value entSensorValue goes below
|
|
the threshold value entSensorThresholdValue
|
|
once it has generated entSensorThresholdNotification.
|
|
The value of entSensorThreshNotifGlobalEnable needs
|
|
to be true.
|
|
|
|
entSensorThresholdSeverity indicates the severity
|
|
of this threshold.
|
|
|
|
The agent implementation guarantees prompt, timely
|
|
evaluation of threshold and generation of this
|
|
notification."
|
|
::= { entitySensorMIBNotifications 2 }
|
|
-- conformance information
|
|
|
|
entitySensorMIBCompliances OBJECT IDENTIFIER
|
|
::= { entitySensorMIBConformance 1 }
|
|
|
|
entitySensorMIBGroups OBJECT IDENTIFIER
|
|
::= { entitySensorMIBConformance 2 }
|
|
|
|
|
|
-- compliance statements
|
|
|
|
entitySensorMIBComplianceV01 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An Entity-MIB implementation that lists
|
|
sensors in its entPhysicalTable must implement
|
|
this group."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
entitySensorValueGroup,
|
|
entitySensorThresholdGroup,
|
|
entitySensorThresholdNotificationGroup
|
|
}
|
|
::= { entitySensorMIBCompliances 1 }
|
|
|
|
entitySensorMIBComplianceV02 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An Entity-MIB implementation that lists
|
|
sensors in its entPhysicalTable must implement
|
|
this group."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { entitySensorThresholdGroup }
|
|
|
|
GROUP entitySensorValueGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for the systems which don't
|
|
support IETF version of ENTITY-SENSOR-MIB."
|
|
|
|
GROUP entitySensorThresholdNotificationGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for the systems which support
|
|
entitySensorValueGroup group."
|
|
|
|
OBJECT entSensorThresholdSeverity
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT entSensorThresholdRelation
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT entSensorThresholdValue
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
::= { entitySensorMIBCompliances 2 }
|
|
|
|
entitySensorMIBComplianceV03 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An Entity-MIB implementation that lists
|
|
sensors in its entPhysicalTable must implement
|
|
this group."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { entitySensorThresholdGroup }
|
|
|
|
GROUP entitySensorValueGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for the systems which don't
|
|
support IETF version of ENTITY-SENSOR-MIB."
|
|
|
|
GROUP entitySensorThresholdNotificationGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for the systems which support
|
|
entitySensorValueGroup group."
|
|
|
|
GROUP entitySensorValueGroupSup1
|
|
DESCRIPTION
|
|
"This group is mandatory for the systems which support
|
|
the correlation between sensor and its measured
|
|
physical entity."
|
|
|
|
OBJECT entSensorThresholdSeverity
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT entSensorThresholdRelation
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT entSensorThresholdValue
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
::= { entitySensorMIBCompliances 3 }
|
|
|
|
entitySensorMIBComplianceV04 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An Entity-MIB implementation that lists
|
|
sensors in its entPhysicalTable must implement
|
|
this group."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { entitySensorThresholdGroup }
|
|
|
|
GROUP entitySensorValueGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for the systems which don't
|
|
support IETF version of ENTITY-SENSOR-MIB."
|
|
|
|
GROUP entitySensorThresholdNotificationGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for the systems which support
|
|
entitySensorValueGroup group."
|
|
|
|
GROUP entitySensorValueGroupSup1
|
|
DESCRIPTION
|
|
"This group is mandatory for the systems which support
|
|
the correlation between sensor and its measured
|
|
physical entity."
|
|
|
|
GROUP entitySensorNotifCtrlGlobalGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for the platforms which support
|
|
global notification control on
|
|
entSensorThresholdNotification."
|
|
|
|
OBJECT entSensorThresholdSeverity
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT entSensorThresholdRelation
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT entSensorThresholdValue
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
::= { entitySensorMIBCompliances 4 }
|
|
|
|
entitySensorMIBComplianceV05 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An Entity-MIB implementation that lists
|
|
sensors in its entPhysicalTable must implement
|
|
this group."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { entitySensorThresholdGroup }
|
|
|
|
GROUP entitySensorValueGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for the systems
|
|
which don't support IETF version of
|
|
ENTITY-SENSOR-MIB."
|
|
|
|
GROUP entitySensorValueGroupSup1
|
|
DESCRIPTION
|
|
"This group is mandatory for the systems
|
|
which don't support IETF version of
|
|
ENTITY-SENSOR-MIB."
|
|
|
|
GROUP entitySensorNotifCtrlGlobalGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for the systems
|
|
which don't support IETF version of
|
|
ENTITY-SENSOR-MIB."
|
|
|
|
GROUP entitySensorNotificationGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for the systems
|
|
which don't support IETF version of
|
|
ENTITY-SENSOR-MIB."
|
|
|
|
OBJECT entSensorThresholdSeverity
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT entSensorThresholdRelation
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT entSensorThresholdValue
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
::= { entitySensorMIBCompliances 5 }
|
|
|
|
-- units of conformance
|
|
|
|
entitySensorValueGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
entSensorType,
|
|
entSensorScale,
|
|
entSensorPrecision,
|
|
entSensorValue,
|
|
entSensorStatus,
|
|
entSensorValueTimeStamp,
|
|
entSensorValueUpdateRate
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects which are used
|
|
to describe and monitor values of Entity-MIB
|
|
entPhysicalTable entries of sensors."
|
|
::= { entitySensorMIBGroups 1 }
|
|
|
|
entitySensorThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
entSensorThresholdSeverity,
|
|
entSensorThresholdRelation,
|
|
entSensorThresholdValue,
|
|
entSensorThresholdEvaluation,
|
|
entSensorThresholdNotificationEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects which are used
|
|
to describe and monitor thresholds for
|
|
sensors."
|
|
::= { entitySensorMIBGroups 2 }
|
|
|
|
entitySensorThresholdNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { entSensorThresholdNotification }
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The collection of notifications used for
|
|
monitoring sensor threshold activity.
|
|
entitySensorThresholdNotificationGroup
|
|
object is superseded by
|
|
entitySensorNotificationGroup."
|
|
::= { entitySensorMIBGroups 3 }
|
|
|
|
entitySensorValueGroupSup1 OBJECT-GROUP
|
|
OBJECTS { entSensorMeasuredEntity }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects which are used to describe and track
|
|
the measured entities of ENTITY-MIB entPhysicalTable."
|
|
::= { entitySensorMIBGroups 4 }
|
|
|
|
entitySensorNotifCtrlGlobalGroup OBJECT-GROUP
|
|
OBJECTS { entSensorThreshNotifGlobalEnable }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects which provide the global
|
|
notification control on entSensorThresholdNotification."
|
|
::= { entitySensorMIBGroups 5 }
|
|
|
|
entitySensorNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
entSensorThresholdNotification,
|
|
entSensorThresholdRecoveryNotification
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of notifications used for
|
|
monitoring sensor threshold activity."
|
|
::= { entitySensorMIBGroups 6 }
|
|
|
|
END
|
|
|
|
|
|
|