-- CISCO-OPTICAL-MONITOR-MIB.my
|
|
--
|
|
-- May 2002, Sonal Maheshwari, Mickey Spiegel
|
|
--
|
|
-- Copyright (c) 2002,-2007 by Cisco Systems, Inc.
|
|
--
|
|
-- All rights reserved.
|
|
-- ****************************************************************
|
|
|
|
CISCO-OPTICAL-MONITOR-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Integer32,
|
|
Unsigned32,
|
|
MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE,
|
|
OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,
|
|
NOTIFICATION-GROUP,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION,
|
|
TimeStamp
|
|
FROM SNMPv2-TC
|
|
ifIndex
|
|
FROM IF-MIB
|
|
ciscoMgmt
|
|
FROM CISCO-SMI;
|
|
|
|
|
|
ciscoOpticalMonitorMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200701020000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
"Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
|
|
Tel: +1 800 553-NETS
|
|
|
|
E-mail: cs-dwdm@cisco.com"
|
|
DESCRIPTION
|
|
"This MIB module defines objects to monitor optical
|
|
characteristics and set corresponding thresholds on the
|
|
optical interfaces in a network element.
|
|
"
|
|
REVISION "200701020000Z"
|
|
DESCRIPTION
|
|
"Add cOpticalMonIfTimeGroup,
|
|
cOpticalMIBEnableConfigGroup,
|
|
cOpticalMIBIntervalConfigGroup,
|
|
cOpticalMonThreshSourceGroup."
|
|
REVISION "200205100000Z"
|
|
DESCRIPTION
|
|
"The initial revision of this MIB."
|
|
::= { ciscoMgmt 264 }
|
|
|
|
|
|
-- Textual Conventions
|
|
|
|
OpticalParameterType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value indicates the optical parameter that is
|
|
being monitored. Valid values are -
|
|
|
|
power (1) : Optical Power (AC + DC) in 1/10ths of dBm
|
|
acPower (2) : Optical AC Power in 1/10ths of dBm
|
|
ambientTemp (3) : Ambient Temperature in 1/10ths of degrees
|
|
centigrade
|
|
laserTemp (4) : Laser Temperature in 1/10ths of degrees
|
|
centigrade
|
|
biasCurrent (5) : Laser bias current in 100s of microamperes
|
|
peltierCurrent (6) : Laser peltier current in milliamperes
|
|
xcvrVoltage (7) : Transceiver voltage in millivolts
|
|
"
|
|
SYNTAX INTEGER {
|
|
power(1),
|
|
acPower(2),
|
|
ambientTemp(3),
|
|
laserTemp(4),
|
|
biasCurrent(5),
|
|
peltierCurrent(6),
|
|
xcvrVoltage(7)
|
|
}
|
|
|
|
OpticalParameterValue ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the optical parameter that is being monitored.
|
|
|
|
The range of values varies depending on the type of optical
|
|
parameter being monitored, as identified by a corresponding
|
|
object with syntax OpticalParameterType.
|
|
|
|
When the optical parameter being monitored is 'power' or
|
|
'acPower', the supported range is from -400 to 250, in
|
|
1/10ths of dBm.
|
|
Example: A value of -300 represents a power level of -30.0 dBm.
|
|
|
|
When the optical parameter being monitored is 'laserTemp' or
|
|
'ambientTemp', the supported range is from -500 to 850, in
|
|
1/10ths of degrees centigrade.
|
|
Example: A value of 235 represents a temperature reading of
|
|
23.5 degrees C.
|
|
|
|
When the optical parameter being monitored is 'biasCurrent',
|
|
the supported range is from 0 to 10000, in 100s of
|
|
microamperes.
|
|
Example: A value of 500 represents a bias current reading of
|
|
50,000 microamperes.
|
|
|
|
When the optical parameter being monitored is 'peltierCurrent',
|
|
the supported range is from -10000 to 10000, in milliamperes.
|
|
|
|
When the optical parameter being monitored is 'xcvrVoltage',
|
|
the supported range is from 0 to 10000, in millivolts.
|
|
|
|
The distinguished value of '-1000000' indicates that the object
|
|
has not yet been initialized or does not apply.
|
|
"
|
|
SYNTAX Integer32 (-1000000..1000000 )
|
|
|
|
OpticalIfDirection ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value indicates the direction being monitored at
|
|
the optical interface.
|
|
"
|
|
SYNTAX INTEGER {
|
|
receive(1),
|
|
transmit(2),
|
|
notApplicable(3)
|
|
}
|
|
|
|
OpticalIfMonLocation ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value applies when there are multiple points
|
|
at which optical characteristics can be measured, in the
|
|
given direction, at an interface. It indicates whether the
|
|
optical characteristics are measured before or after
|
|
adjustment (e.g. optical amplification or attenuation).
|
|
|
|
The codepoint 'notApplicable' should be used if no
|
|
amplifier/attenuator exists at an interface.
|
|
"
|
|
SYNTAX INTEGER {
|
|
beforeAdjustment(1),
|
|
afterAdjustment(2),
|
|
notApplicable(3)
|
|
}
|
|
|
|
OpticalAlarmStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bitmap that indicates the current status of thresholds
|
|
on an interface. The bit is set to 1 if the threshold is
|
|
currently being exceeded on the interface and will be set to 0
|
|
otherwise.
|
|
|
|
(MSB) (LSB)
|
|
7 6 5 4 3 2 1 0
|
|
+----------------------+
|
|
| |
|
|
+----------------------+
|
|
| | | |
|
|
| | | +-- High alarm threshold
|
|
| | +----- High warning threshold
|
|
| +-------- Low alarm threshold
|
|
+----------- Low warning threshold
|
|
|
|
To minimize the probability of prematurely reacting to
|
|
momentary signal variations, a soak time may be incorporated
|
|
into the status indications in the following manner.
|
|
The indication is set when the threshold violation persists
|
|
for a period of time that exceeds the set soak interval.
|
|
The indication is cleared when no threshold violation occurs
|
|
for a period of time which exceeds the clear soak interval.
|
|
In GR-2918-CORE, the recommended set soak interval is 2.5
|
|
seconds (plus/minus 0.5 seconds), and the recommended clear
|
|
soak interval is 10 seconds (plus/minus 0.5 seconds).
|
|
"
|
|
|
|
REFERENCE
|
|
"Telcordia Technologies Generic Requirements
|
|
GR-2918-CORE, Issue 4, December 1999, Section 8.11"
|
|
SYNTAX OCTET STRING (SIZE (1))
|
|
|
|
OpticalAlarmSeverity ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of a trouble condition. A smaller enumerated
|
|
integer value indicates that the condition is more severe.
|
|
|
|
The severities are defined as follows:
|
|
|
|
'critical' An alarm used to indicate a severe,
|
|
service-affecting condition has occurred and that
|
|
immediate corrective action is imperative,
|
|
regardless of the time of day or day of the week.
|
|
|
|
'major' An alarm used for hardware or software conditions
|
|
that indicate a serious disruption of service or
|
|
malfunctioning or failure of important hardware.
|
|
These troubles require the immediate attention and
|
|
response of a technician to restore or maintain
|
|
system capability. The urgency is less than in
|
|
critical situations because of a lesser immediate
|
|
or impending effect on service or system
|
|
performance.
|
|
|
|
'minor' An alarm used for troubles that do not have a
|
|
serious effect on service to customers or for
|
|
troubles in hardware that are not essential to
|
|
the operation of the system.
|
|
|
|
'notAlarmed' An event used for troubles that do not require
|
|
action, for troubles that are reported as a
|
|
result of manually initiated diagnostics, or for
|
|
transient events such as crossing warning
|
|
thresholds. This event can also be used to
|
|
raise attention to a condition that could
|
|
possibly be an impending problem.
|
|
|
|
'notReported' An event used for troubles similar to those
|
|
described under 'notAlarmed', and that
|
|
do not cause notifications to be generated. The
|
|
information for these events is retrievable from
|
|
the network element.
|
|
|
|
'cleared' This value indicates that a previously
|
|
occuring alarm condition has been cleared, or
|
|
that no trouble condition is present.
|
|
|
|
"
|
|
|
|
REFERENCE
|
|
"Telcordia Technologies Generic Requirements
|
|
GR-474-CORE, Issue 1, December 1997, Section 2.2"
|
|
SYNTAX INTEGER {
|
|
critical(1),
|
|
major(2),
|
|
minor(3),
|
|
notAlarmed(4),
|
|
notReported(5),
|
|
cleared(6)
|
|
}
|
|
|
|
OpticalAlarmSeverityOrZero ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value of either '0' or a valid optical alarm severity."
|
|
SYNTAX INTEGER (0..6)
|
|
|
|
OpticalPMPeriod ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value indicates the time period over which performance
|
|
monitoring data has been collected."
|
|
SYNTAX INTEGER {
|
|
fifteenMin(1),
|
|
twentyFourHour(2)
|
|
}
|
|
-- MIB Object Definitions
|
|
cOpticalMonitorMIBObjects OBJECT IDENTIFIER
|
|
::= { ciscoOpticalMonitorMIB 1 }
|
|
|
|
-- groups in this MIB module
|
|
cOpticalMonGroup OBJECT IDENTIFIER
|
|
::= { cOpticalMonitorMIBObjects 1 }
|
|
|
|
cOpticalPMGroup OBJECT IDENTIFIER
|
|
::= { cOpticalMonitorMIBObjects 2 }
|
|
|
|
-- cOpticalMonTable
|
|
|
|
cOpticalMonTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF COpticalMonEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides objects to monitor optical
|
|
parameters in a network element. It also provides
|
|
objects for setting high and low threshold levels, with
|
|
configurable severities, on these monitored parameters."
|
|
::= { cOpticalMonGroup 1 }
|
|
|
|
cOpticalMonEntry OBJECT-TYPE
|
|
SYNTAX COpticalMonEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the cOpticalMonTable provides objects to
|
|
monitor an optical parameter and set threshold levels
|
|
on that parameter, at an optical interface.
|
|
|
|
Note that the set of monitored optical parameters may vary
|
|
based on interface type, direction, and monitoring location.
|
|
|
|
Examples of interfaces that can have an entry in this table
|
|
include optical transceivers, interfaces before and after
|
|
optical amplifiers, and interfaces before and after optical
|
|
attenuators."
|
|
INDEX {
|
|
ifIndex,
|
|
cOpticalMonDirection,
|
|
cOpticalMonLocation,
|
|
cOpticalMonParameterType
|
|
}
|
|
::= { cOpticalMonTable 1 }
|
|
|
|
COpticalMonEntry ::= SEQUENCE {
|
|
cOpticalMonDirection OpticalIfDirection,
|
|
cOpticalMonLocation OpticalIfMonLocation,
|
|
cOpticalMonParameterType OpticalParameterType,
|
|
cOpticalParameterValue OpticalParameterValue,
|
|
cOpticalParamHighAlarmThresh OpticalParameterValue,
|
|
cOpticalParamHighAlarmSev OpticalAlarmSeverity,
|
|
cOpticalParamHighWarningThresh OpticalParameterValue,
|
|
cOpticalParamHighWarningSev OpticalAlarmSeverity,
|
|
cOpticalParamLowAlarmThresh OpticalParameterValue,
|
|
cOpticalParamLowAlarmSev OpticalAlarmSeverity,
|
|
cOpticalParamLowWarningThresh OpticalParameterValue,
|
|
cOpticalParamLowWarningSev OpticalAlarmSeverity,
|
|
cOpticalParamAlarmStatus OpticalAlarmStatus,
|
|
cOpticalParamAlarmCurMaxThresh OpticalParameterValue,
|
|
cOpticalParamAlarmCurMaxSev OpticalAlarmSeverity,
|
|
cOpticalParamAlarmLastChange TimeStamp,
|
|
cOpticalMon15MinValidIntervals Unsigned32,
|
|
cOpticalMon24HrValidIntervals Unsigned32,
|
|
cOpticalParamThreshSource BITS
|
|
}
|
|
|
|
cOpticalMonDirection OBJECT-TYPE
|
|
SYNTAX OpticalIfDirection
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the direction monitored for the
|
|
optical interface, in this entry."
|
|
::= { cOpticalMonEntry 1 }
|
|
|
|
cOpticalMonLocation OBJECT-TYPE
|
|
SYNTAX OpticalIfMonLocation
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the optical characteristics are
|
|
measured before or after adjustment (e.g. optical amplification
|
|
or attenuation), at this interface."
|
|
::= { cOpticalMonEntry 2 }
|
|
|
|
cOpticalMonParameterType OBJECT-TYPE
|
|
SYNTAX OpticalParameterType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the optical parameter that is being
|
|
monitored in this entry."
|
|
::= { cOpticalMonEntry 3 }
|
|
|
|
cOpticalParameterValue OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the value measured for the particular
|
|
optical parameter specified by the cOpticalMonParameterType
|
|
object."
|
|
::= { cOpticalMonEntry 4 }
|
|
|
|
cOpticalParamHighAlarmThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set a high alarm threshold on the
|
|
optical parameter being monitored.
|
|
|
|
An alarm condition will be raised if the value given by
|
|
cOpticalParameterValue goes from below the value configured in
|
|
this object to above the value configured in this object, or if
|
|
the initial value of cOpticalParameterValue exceeds the value
|
|
configured in this object. For network elements that
|
|
incorporate a soak time in the status indications, this alarm
|
|
will be indicated in the cOpticalParamAlarmStatus object only
|
|
after it persists for a period of time that equals the set soak
|
|
interval.
|
|
|
|
The severity level of the alarm is specified by the
|
|
cOpticalParamHighAlarmSev object.
|
|
|
|
When the cOpticalMonParameterType object is set to 'power'
|
|
for the receive direction at a transceiver, this object
|
|
specifies the receiver saturation level."
|
|
::= { cOpticalMonEntry 5 }
|
|
|
|
cOpticalParamHighAlarmSev OBJECT-TYPE
|
|
SYNTAX OpticalAlarmSeverity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to specify a severity level associated
|
|
with the high alarm threshold given by the
|
|
cOpticalParamHighAlarmThresh object. The values 'notAlarmed',
|
|
'notReported', and 'cleared' do not apply.
|
|
|
|
The severity level configured in this object must be higher
|
|
than the level configured in the cOpticalParamHighWarningSev
|
|
object."
|
|
::= { cOpticalMonEntry 6 }
|
|
|
|
cOpticalParamHighWarningThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set a high warning threshold on
|
|
the optical parameter being monitored.
|
|
|
|
A threshold crossing condition will be indicated if the value
|
|
given by cOpticalParameterValue goes from below the value
|
|
configured in this object to above the value configured in this
|
|
object, or if the initial value of cOpticalParameterValue
|
|
exceeds the value configured in this object. For network
|
|
elements that incorporate a soak time in the status
|
|
indications, this threshold violation will be indicated in the
|
|
cOpticalParamAlarmStatus object only after it persists for
|
|
a period of time that equals the set soak interval.
|
|
|
|
This threshold crossing may or may not be alarmed or
|
|
reported, based on the severity level specified by the
|
|
cOpticalParamHighWarningSev object."
|
|
::= { cOpticalMonEntry 7 }
|
|
|
|
cOpticalParamHighWarningSev OBJECT-TYPE
|
|
SYNTAX OpticalAlarmSeverity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to specify a severity level associated
|
|
with the high warning threshold given by the
|
|
cOpticalParamHighWarningThresh object. The values 'critical',
|
|
'major', and 'cleared' do not apply.
|
|
|
|
The severity level configured in this object must be lower
|
|
than the level configured in the cOpticalParamHighAlarmSev
|
|
object.
|
|
|
|
If this object is set to 'notReported', no notifications will
|
|
be generated when this threshold is exceeded, irrespective
|
|
of the value configured in the cOpticalNotifyEnable object."
|
|
::= { cOpticalMonEntry 8 }
|
|
|
|
cOpticalParamLowAlarmThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set a low alarm threshold on the
|
|
optical parameter being monitored.
|
|
|
|
An alarm condition will be raised if the value given by
|
|
cOpticalParameterValue goes from above the value configured in
|
|
this object to below the value configured in this object, or if
|
|
the initial value of cOpticalParameterValue is lower than the
|
|
value configured in this object. For network elements that
|
|
incorporate a soak time in the status indications, this alarm
|
|
will be indicated in the cOpticalParamAlarmStatus object only
|
|
after it persists for a period of time that equals the set soak
|
|
interval.
|
|
|
|
The severity level of this alarm is specified by the
|
|
cOpticalParamLowAlarmSev object.
|
|
|
|
When the cOpticalMonParameterType object is set to 'power'
|
|
for the receive direction and when the interface supports
|
|
alarms based on loss of light, this object specifies the
|
|
optical power threshold for declaring loss of light. Also,
|
|
when optical amplifiers are present in the network, in the
|
|
receive direction, this value may need to be configured,
|
|
since the noise floor may be higher than the minimum
|
|
sensitivity of the receiver."
|
|
::= { cOpticalMonEntry 9 }
|
|
|
|
cOpticalParamLowAlarmSev OBJECT-TYPE
|
|
SYNTAX OpticalAlarmSeverity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to specify a severity level associated
|
|
with the low alarm threshold given by the
|
|
cOpticalParamLowAlarmThresh object. The values 'notAlarmed',
|
|
'notReported', and 'cleared' do not apply.
|
|
|
|
The severity level configured in this object must be higher
|
|
than the level configured in the cOpticalParamLowWarningSev
|
|
object."
|
|
::= { cOpticalMonEntry 10 }
|
|
|
|
cOpticalParamLowWarningThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set a low warning threshold on
|
|
the optical parameter being monitored.
|
|
|
|
A threshold crossing condition will be indicated if the value
|
|
given by cOpticalParameterValue goes from above the value
|
|
configured in this object to below the value configured in this
|
|
object, or if the initial value of cOpticalParameterValue
|
|
object is lower than the value configured in this object. For
|
|
network elements that incorporate a soak time in the status
|
|
indications, this threshold violation will be indicated in the
|
|
cOpticalParamAlarmStatus object only after it persists for
|
|
a period of time that equals the set soak interval.
|
|
|
|
This threshold crossing may or may not be alarmed or
|
|
reported, based on the severity level specified by the
|
|
cOpticalParamLowWarningSev object."
|
|
::= { cOpticalMonEntry 11 }
|
|
|
|
cOpticalParamLowWarningSev OBJECT-TYPE
|
|
SYNTAX OpticalAlarmSeverity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to specify a severity level associated
|
|
with the low warning threshold given by the
|
|
cOpticalParamLowWarningThresh object. The values 'critical',
|
|
'major', and 'cleared' do not apply.
|
|
|
|
The severity level configured in this object must be lower
|
|
than the level configured in the cOpticalParamLowAlarmSev
|
|
object.
|
|
|
|
If this object is set to 'notReported', no notifications will
|
|
be generated when this threshold is exceeded, irrespective
|
|
of the value configured in the cOpticalNotifyEnable object."
|
|
::= { cOpticalMonEntry 12 }
|
|
|
|
cOpticalParamAlarmStatus OBJECT-TYPE
|
|
SYNTAX OpticalAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to indicate the current status of
|
|
the thresholds for the monitored optical parameter
|
|
on the interface.
|
|
|
|
If a threshold is currently being exceeded on the
|
|
interface, the corresponding bit in this object will be set
|
|
to 1. Otherwise, the bit will be set to 0."
|
|
::= { cOpticalMonEntry 13 }
|
|
|
|
cOpticalParamAlarmCurMaxThresh OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the threshold value of the highest
|
|
severity threshold that is currently being exceeded
|
|
on the interface, for the optical parameter.
|
|
If no threshold value is currently being
|
|
exceeded, then the value '-1000000' is returned."
|
|
::= { cOpticalMonEntry 14 }
|
|
|
|
cOpticalParamAlarmCurMaxSev OBJECT-TYPE
|
|
SYNTAX OpticalAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the maximum severity of any thresholds
|
|
that are currently being exceeded on the interface, for the
|
|
optical parameter."
|
|
::= { cOpticalMonEntry 15 }
|
|
|
|
cOpticalParamAlarmLastChange OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the value of sysUpTime at the last time
|
|
a threshold related to a particular optical parameter was
|
|
exceeded or cleared on the interface."
|
|
::= { cOpticalMonEntry 16 }
|
|
|
|
cOpticalMon15MinValidIntervals OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..96 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the number of previous 15 minute
|
|
intervals for which valid performance monitoring data
|
|
has been stored on the interface.
|
|
|
|
The value of this object will be n (where n is the maximum
|
|
number of 15 minute intervals supported at this interface),
|
|
unless the measurement was (re-)started within the last
|
|
(nx15) minutes, in which case the value will be the
|
|
number of previous 15 minute intervals for which the agent
|
|
has some data."
|
|
::= { cOpticalMonEntry 17 }
|
|
|
|
cOpticalMon24HrValidIntervals OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the number of previous 24 hour
|
|
intervals for which valid performance monitoring data
|
|
has been stored on the interface.
|
|
|
|
The value of this object will be 0 if the measurement
|
|
was (re-)started within the last 24 hours, or 1 otherwise."
|
|
::= { cOpticalMonEntry 18 }
|
|
|
|
cOpticalParamThreshSource OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
highAlarmDefThresh(0),
|
|
highWarnDefThresh(1),
|
|
lowAlarmDefThresh(2),
|
|
lowWarnDefThresh(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if the current value of a particular
|
|
threshold in this entry is user configured value or it is
|
|
a system default value. It also allows user to specify
|
|
the list of thresholds for this entry which should
|
|
be restored to their system default values.
|
|
|
|
The bit 'highAlarmThresh' corresponds to the object
|
|
cOpticalParamHighAlarmThresh.
|
|
|
|
The bit 'highWarnThresh' corresponds to the object
|
|
cOpticalParamHighWarningThresh.
|
|
|
|
The bit 'lowAlarmThresh' corresponds to the object
|
|
cOpticalParamLowAlarmThresh.
|
|
|
|
The bit 'lowWarnThresh' corresponds to the object
|
|
cOpticalParamLowWarningThresh.
|
|
|
|
A value of 0 for a bit indicates that corresponding
|
|
object has system default value of threshold.
|
|
|
|
A value of 1 for a bit indicates that corresponding
|
|
object has user configured threshold value.
|
|
|
|
A user may only change value of each of the bits to zero.
|
|
|
|
Setting a bit to 0 will reset the corresponding
|
|
threshold to its default value.
|
|
|
|
System will change a bit from 0 to 1 when its corresponding
|
|
threshold is changed by user from its default to any
|
|
other value."
|
|
::= { cOpticalMonEntry 19 }
|
|
|
|
|
|
|
|
-- Notification related objects
|
|
cOpticalNotifyEnable OBJECT-TYPE
|
|
SYNTAX OpticalAlarmSeverityOrZero
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the minimum severity threshold governing
|
|
the generation of cOpticalMonParameterStatus notifications.
|
|
|
|
For example, if the value of this object is
|
|
set to 'major', then the agent generates these notifications
|
|
if and only if the severity of the alarm being indicated is
|
|
'major' or 'critical'.
|
|
|
|
The values of 'notReported', and 'cleared' do not apply.
|
|
The value of '0' disables the generation of notifications."
|
|
DEFVAL { 0 }
|
|
::= { cOpticalMonGroup 2 }
|
|
|
|
-- Scalar object(s) for optical monitoring configuration.
|
|
cOpticalMonEnable OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
all(0)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the types of transceivers for which
|
|
optical monitoring is enabled.
|
|
|
|
A value of 1 for the bit 'all', specifies that optical
|
|
monitoring functionality is enabled for all the types of
|
|
transceivers which are supported by system and have
|
|
optical monitoring capability."
|
|
::= { cOpticalMonGroup 3 }
|
|
|
|
cOpticalMonPollInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the interval in minutes after which
|
|
optical transceiver data will be polled by system
|
|
repeatedly and updated in cOpticalMonTable when one or
|
|
more bits in cOpticalMonEnable is set."
|
|
::= { cOpticalMonGroup 4 }
|
|
-- cOpticalMonTransceiverTable
|
|
|
|
cOpticalMonIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF COpticalMonIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the list of optical interfaces
|
|
populated in cOpticalMonTable."
|
|
::= { cOpticalMonGroup 5 }
|
|
|
|
cOpticalMonIfEntry OBJECT-TYPE
|
|
SYNTAX COpticalMonIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing the information for a particular optical interface."
|
|
INDEX { ifIndex }
|
|
::= { cOpticalMonIfTable 1 }
|
|
|
|
COpticalMonIfEntry ::= SEQUENCE {
|
|
cOpticalMonIfTimeInSlot Unsigned32
|
|
}
|
|
|
|
cOpticalMonIfTimeInSlot OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates when this optical transceiver was detected by the
|
|
system."
|
|
::= { cOpticalMonIfEntry 1 }
|
|
|
|
|
|
-- cOpticalPMCurrent Table
|
|
|
|
cOpticalPMCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF COpticalPMCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains performance monitoring data for the
|
|
various optical parameters, collected over the current 15
|
|
minute or the current 24 hour interval."
|
|
::= { cOpticalPMGroup 1 }
|
|
|
|
cOpticalPMCurrentEntry OBJECT-TYPE
|
|
SYNTAX COpticalPMCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the cOpticalPMCurrentTable. It contains
|
|
performance monitoring data for a monitored optical
|
|
parameter at an interface, collected over the current 15
|
|
minute or the current 24 hour interval.
|
|
|
|
Note that the set of monitored optical parameters may vary
|
|
based on interface type, direction, and monitoring location.
|
|
|
|
Examples of interfaces that can have an entry in this table
|
|
include optical transceivers, interfaces before and after
|
|
optical amplifiers, and interfaces before and after optical
|
|
attenuators."
|
|
INDEX {
|
|
cOpticalPMCurrentPeriod,
|
|
ifIndex,
|
|
cOpticalPMCurrentDirection,
|
|
cOpticalPMCurrentLocation,
|
|
cOpticalPMCurrentParamType
|
|
}
|
|
::= { cOpticalPMCurrentTable 1 }
|
|
|
|
COpticalPMCurrentEntry ::= SEQUENCE {
|
|
cOpticalPMCurrentPeriod OpticalPMPeriod,
|
|
cOpticalPMCurrentDirection OpticalIfDirection,
|
|
cOpticalPMCurrentLocation OpticalIfMonLocation,
|
|
cOpticalPMCurrentParamType OpticalParameterType,
|
|
cOpticalPMCurrentMaxParam OpticalParameterValue,
|
|
cOpticalPMCurrentMinParam OpticalParameterValue,
|
|
cOpticalPMCurrentMeanParam OpticalParameterValue,
|
|
cOpticalPMCurrentUnavailSecs Integer32
|
|
}
|
|
|
|
cOpticalPMCurrentPeriod OBJECT-TYPE
|
|
SYNTAX OpticalPMPeriod
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the optical parameter values
|
|
given in this entry are collected over the current 15 minute or
|
|
the current 24 hour interval."
|
|
::= { cOpticalPMCurrentEntry 1 }
|
|
|
|
cOpticalPMCurrentDirection OBJECT-TYPE
|
|
SYNTAX OpticalIfDirection
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the direction monitored for the optical
|
|
interface, in this entry."
|
|
::= { cOpticalPMCurrentEntry 2 }
|
|
|
|
cOpticalPMCurrentLocation OBJECT-TYPE
|
|
SYNTAX OpticalIfMonLocation
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the optical characteristics are
|
|
measured before or after adjustment (e.g. optical amplification
|
|
or attenuation), at this interface."
|
|
::= { cOpticalPMCurrentEntry 3 }
|
|
|
|
cOpticalPMCurrentParamType OBJECT-TYPE
|
|
SYNTAX OpticalParameterType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the optical parameter that is being
|
|
monitored, in this entry."
|
|
::= { cOpticalPMCurrentEntry 4 }
|
|
|
|
cOpticalPMCurrentMaxParam OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the maximum value measured for the monitored
|
|
optical parameter, in the current 15 minute or the current
|
|
24 hour interval."
|
|
::= { cOpticalPMCurrentEntry 5 }
|
|
|
|
cOpticalPMCurrentMinParam OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the minimum value measured for the monitored
|
|
optical parameter, in the current 15 minute or the current
|
|
24 hour interval."
|
|
::= { cOpticalPMCurrentEntry 6 }
|
|
|
|
cOpticalPMCurrentMeanParam OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the average value of the monitored
|
|
optical parameter, in the current 15 minute or the current
|
|
24 hour interval."
|
|
::= { cOpticalPMCurrentEntry 7 }
|
|
|
|
cOpticalPMCurrentUnavailSecs OBJECT-TYPE
|
|
SYNTAX Integer32 (0..86400 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to indicate the number of seconds,
|
|
in the current 15 minute or the current 24 hour interval, for
|
|
which the optical performance data is not accounted for.
|
|
|
|
In the receive direction, the performance data could be
|
|
unavailable during these periods for multiple reasons
|
|
like the interface being administratively down or if there
|
|
is a Loss of Light alarm on the interface. In the transmit
|
|
direction, performance data could be unavailable when
|
|
the laser is shutdown."
|
|
::= { cOpticalPMCurrentEntry 8 }
|
|
|
|
|
|
-- cOpticalPMInterval Table
|
|
|
|
cOpticalPMIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF COpticalPMIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table stores performance monitoring data for the
|
|
various optical parameters, collected over previous
|
|
intervals.
|
|
|
|
This table can have entries for one complete 24 hour
|
|
interval and up to 96 complete 15 minute
|
|
intervals. A system is required to store at least
|
|
4 completed 15 minute intervals. The number of valid
|
|
15 minute intervals in this table is indicated by the
|
|
cOpticalMon15MinValidIntervals object and the number of
|
|
valid 24 hour intervals is indicated by the
|
|
cOpticalMon24HrValidIntervals object."
|
|
::= { cOpticalPMGroup 2 }
|
|
|
|
cOpticalPMIntervalEntry OBJECT-TYPE
|
|
SYNTAX COpticalPMIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the cOpticalPMIntervalTable. It contains
|
|
performance monitoring data for an optical parameter,
|
|
collected over a previous interval.
|
|
|
|
Note that the set of monitored optical parameters may vary
|
|
based on interface type, direction, and monitoring location.
|
|
|
|
Examples of interfaces that can have an entry in this table
|
|
include optical transceivers, interfaces before and after
|
|
optical amplifiers, and interfaces before and after optical
|
|
attenuators."
|
|
INDEX {
|
|
cOpticalPMIntervalPeriod,
|
|
cOpticalPMIntervalNumber,
|
|
ifIndex,
|
|
cOpticalPMIntervalDirection,
|
|
cOpticalPMIntervalLocation,
|
|
cOpticalPMIntervalParamType
|
|
}
|
|
::= { cOpticalPMIntervalTable 1 }
|
|
|
|
COpticalPMIntervalEntry ::= SEQUENCE {
|
|
cOpticalPMIntervalPeriod OpticalPMPeriod,
|
|
cOpticalPMIntervalNumber Integer32,
|
|
cOpticalPMIntervalDirection OpticalIfDirection,
|
|
cOpticalPMIntervalLocation OpticalIfMonLocation,
|
|
cOpticalPMIntervalParamType OpticalParameterType,
|
|
cOpticalPMIntervalMaxParam OpticalParameterValue,
|
|
cOpticalPMIntervalMinParam OpticalParameterValue,
|
|
cOpticalPMIntervalMeanParam OpticalParameterValue,
|
|
cOpticalPMIntervalUnavailSecs Integer32
|
|
}
|
|
|
|
cOpticalPMIntervalPeriod OBJECT-TYPE
|
|
SYNTAX OpticalPMPeriod
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the optical parameter values,
|
|
given in this entry, are collected over a period of 15 minutes
|
|
or 24 hours."
|
|
::= { cOpticalPMIntervalEntry 1 }
|
|
|
|
cOpticalPMIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, which identifies the
|
|
interval for which the set of optical parameter values is
|
|
available. The interval identified by 1 is the most recently
|
|
completed 15 minute or 24 hour interval, and the interval
|
|
identified by N is the interval immediately preceding the one
|
|
identified by N-1."
|
|
::= { cOpticalPMIntervalEntry 2 }
|
|
|
|
cOpticalPMIntervalDirection OBJECT-TYPE
|
|
SYNTAX OpticalIfDirection
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the direction monitored for the optical
|
|
interface, in this entry."
|
|
::= { cOpticalPMIntervalEntry 3 }
|
|
|
|
cOpticalPMIntervalLocation OBJECT-TYPE
|
|
SYNTAX OpticalIfMonLocation
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the optical characteristics
|
|
are measured before or after adjustment (e.g.
|
|
optical amplification or attenuation), at this interface."
|
|
::= { cOpticalPMIntervalEntry 4 }
|
|
|
|
cOpticalPMIntervalParamType OBJECT-TYPE
|
|
SYNTAX OpticalParameterType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the optical parameter that is being
|
|
monitored, in this entry."
|
|
::= { cOpticalPMIntervalEntry 5 }
|
|
|
|
cOpticalPMIntervalMaxParam OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the maximum value measured for the optical
|
|
parameter, in a particular 15 minute or 24 hour interval."
|
|
::= { cOpticalPMIntervalEntry 6 }
|
|
|
|
cOpticalPMIntervalMinParam OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the minimum value measured for the optical
|
|
parameter, in a particular 15 minute or 24 hour interval."
|
|
::= { cOpticalPMIntervalEntry 7 }
|
|
|
|
cOpticalPMIntervalMeanParam OBJECT-TYPE
|
|
SYNTAX OpticalParameterValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object gives the average value of the measured optical
|
|
parameter, in a particular 15 minute or 24 hour interval."
|
|
::= { cOpticalPMIntervalEntry 8 }
|
|
|
|
cOpticalPMIntervalUnavailSecs OBJECT-TYPE
|
|
SYNTAX Integer32 (0..86400 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to indicate the number of seconds,
|
|
in the particular 15 minute or 24 hour interval, for which the
|
|
optical performance data is not accounted for.
|
|
|
|
In the receive direction, the performance data could be
|
|
unavailable during these periods for multiple reasons
|
|
like the interface being administratively down or if there
|
|
is a Loss of Light alarm on the interface. In the transmit
|
|
direction, performance data could be unavailable when
|
|
the laser is shutdown."
|
|
::= { cOpticalPMIntervalEntry 9 }
|
|
|
|
|
|
-- Notifications
|
|
cOpticalMonitorMIBNotifications OBJECT IDENTIFIER
|
|
::= { ciscoOpticalMonitorMIB 2 }
|
|
|
|
cOpticalMonNotificationPrefix OBJECT IDENTIFIER
|
|
::= { cOpticalMonitorMIBNotifications 0 }
|
|
|
|
|
|
|
|
cOpticalMonParameterStatus NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cOpticalParameterValue,
|
|
cOpticalParamAlarmStatus,
|
|
cOpticalParamAlarmCurMaxThresh,
|
|
cOpticalParamAlarmCurMaxSev,
|
|
cOpticalParamAlarmLastChange
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when any threshold related to an
|
|
optical parameter is exceeded or cleared on an interface.
|
|
|
|
This notification may be suppressed under the following
|
|
conditions:
|
|
- depending on the value of the cOpticalNotifyEnable object,
|
|
or
|
|
- if the severity of the threshold as specified by
|
|
the cOpticalParamHighWarningSev or
|
|
cOpticalParamLowWarningSev object is 'notReported'.
|
|
"
|
|
::= { cOpticalMonNotificationPrefix 1 }
|
|
-- MIB Conformance Statements
|
|
cOpticalMonitorMIBConformance OBJECT IDENTIFIER
|
|
::= { ciscoOpticalMonitorMIB 3 }
|
|
|
|
cOpticalMonitorMIBCompliances OBJECT IDENTIFIER
|
|
::= { cOpticalMonitorMIBConformance 1 }
|
|
|
|
cOpticalMonitorMIBGroups OBJECT IDENTIFIER
|
|
::= { cOpticalMonitorMIBConformance 2 }
|
|
|
|
|
|
cOpticalMonitorMIBCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for network elements that
|
|
monitor optical characteristics and set thresholds on the
|
|
optical interfaces in a network element."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { cOpticalMIBMonGroup }
|
|
|
|
GROUP cOpticalMIBThresholdGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that support
|
|
thresholds on optical parameters."
|
|
|
|
GROUP cOpticalMIBSeverityGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that support
|
|
severities for thresholds on optical parameters."
|
|
|
|
GROUP cOpticalMIBPMGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that
|
|
support collection of optical performance monitoring
|
|
data for 15 minute or 24 hour intervals."
|
|
|
|
GROUP cOpticalMIBNotifyEnableGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that
|
|
support the cOpticalMIBNotifGroup."
|
|
|
|
GROUP cOpticalMIBNotifGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that
|
|
generate notifications when a threshold is exceeded or
|
|
cleared on an interface."
|
|
|
|
OBJECT cOpticalParamHighAlarmThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamHighWarningThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamLowAlarmThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamLowWarningThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamHighAlarmSev
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamHighWarningSev
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamLowAlarmSev
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamLowWarningSev
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
::= { cOpticalMonitorMIBCompliances 1 }
|
|
|
|
cOpticalMonitorMIBComplianceRev MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for network elements that
|
|
monitor optical characteristics and set thresholds on the
|
|
optical interfaces in a network element."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { cOpticalMIBMonGroup }
|
|
|
|
GROUP cOpticalMIBThresholdGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that support
|
|
thresholds on optical parameters."
|
|
|
|
GROUP cOpticalMIBSeverityGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that support
|
|
severities for thresholds on optical parameters."
|
|
|
|
GROUP cOpticalMIBPMGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that
|
|
support collection of optical performance monitoring
|
|
data for 15 minute or 24 hour intervals."
|
|
|
|
GROUP cOpticalMonIfTimeGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that maintain
|
|
time related information for optical transceivers."
|
|
|
|
GROUP cOpticalMIBNotifyEnableGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that
|
|
support the cOpticalMIBNotifGroup."
|
|
|
|
GROUP cOpticalMIBNotifGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that
|
|
generate notifications when a threshold is exceeded or
|
|
cleared on an interface."
|
|
|
|
GROUP cOpticalMIBEnableConfigGroup
|
|
DESCRIPTION
|
|
"This group is required for network elements that
|
|
are capable of enabling/disabling optical monitoring
|
|
functionality."
|
|
|
|
GROUP cOpticalMIBIntervalConfigGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for network elements that
|
|
support optical monitoring polling interval
|
|
configuration."
|
|
|
|
GROUP cOpticalMonThreshSourceGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for the network elements that
|
|
support restoring the optical monitoring threshold
|
|
to the default value."
|
|
|
|
OBJECT cOpticalParamHighAlarmThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamHighWarningThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamLowAlarmThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamLowWarningThresh
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamHighAlarmSev
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamHighWarningSev
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamLowAlarmSev
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
|
|
OBJECT cOpticalParamLowWarningSev
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
::= { cOpticalMonitorMIBCompliances 2 }
|
|
|
|
-- Units of Conformance
|
|
cOpticalMIBMonGroup OBJECT-GROUP
|
|
OBJECTS { cOpticalParameterValue }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A mandatory object that provides monitoring of optical
|
|
characteristics."
|
|
::= { cOpticalMonitorMIBGroups 1 }
|
|
|
|
cOpticalMIBThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cOpticalParamHighAlarmThresh,
|
|
cOpticalParamHighWarningThresh,
|
|
cOpticalParamLowAlarmThresh,
|
|
cOpticalParamLowWarningThresh,
|
|
cOpticalParamAlarmStatus,
|
|
cOpticalParamAlarmCurMaxThresh,
|
|
cOpticalParamAlarmLastChange
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that support thresholds on optical
|
|
parameters and provide status information when the thresholds
|
|
are exceeded or cleared."
|
|
::= { cOpticalMonitorMIBGroups 2 }
|
|
|
|
cOpticalMIBSeverityGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cOpticalParamHighAlarmSev,
|
|
cOpticalParamHighWarningSev,
|
|
cOpticalParamLowAlarmSev,
|
|
cOpticalParamLowWarningSev,
|
|
cOpticalParamAlarmCurMaxSev
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that support severities for thresholds
|
|
on optical parameters."
|
|
::= { cOpticalMonitorMIBGroups 3 }
|
|
|
|
cOpticalMIBPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cOpticalMon15MinValidIntervals,
|
|
cOpticalMon24HrValidIntervals,
|
|
cOpticalPMCurrentMaxParam,
|
|
cOpticalPMCurrentMinParam,
|
|
cOpticalPMCurrentMeanParam,
|
|
cOpticalPMCurrentUnavailSecs,
|
|
cOpticalPMIntervalMaxParam,
|
|
cOpticalPMIntervalMinParam,
|
|
cOpticalPMIntervalMeanParam,
|
|
cOpticalPMIntervalUnavailSecs
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that provide optical performance
|
|
monitoring data for 15 minute and 24 hour intervals."
|
|
::= { cOpticalMonitorMIBGroups 4 }
|
|
|
|
cOpticalMIBNotifyEnableGroup OBJECT-GROUP
|
|
OBJECTS { cOpticalNotifyEnable }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An object to control the generation of notifications."
|
|
::= { cOpticalMonitorMIBGroups 5 }
|
|
|
|
cOpticalMIBNotifGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { cOpticalMonParameterStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A notification generated when a threshold on an optical
|
|
parameter is exceeded or cleared."
|
|
::= { cOpticalMonitorMIBGroups 6 }
|
|
|
|
cOpticalMonIfTimeGroup OBJECT-GROUP
|
|
OBJECTS { cOpticalMonIfTimeInSlot }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of object(s) that provide time related information
|
|
for transceivers in the system."
|
|
::= { cOpticalMonitorMIBGroups 7 }
|
|
|
|
cOpticalMIBEnableConfigGroup OBJECT-GROUP
|
|
OBJECTS { cOpticalMonEnable }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of object(s) to enable/disable optical
|
|
monitoring."
|
|
::= { cOpticalMonitorMIBGroups 8 }
|
|
|
|
cOpticalMIBIntervalConfigGroup OBJECT-GROUP
|
|
OBJECTS { cOpticalMonPollInterval }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of object(s) to specify polling interval for
|
|
monitoring optical transceivers."
|
|
::= { cOpticalMonitorMIBGroups 9 }
|
|
|
|
cOpticalMonThreshSourceGroup OBJECT-GROUP
|
|
OBJECTS { cOpticalParamThreshSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of object(s) to restore a given threshold
|
|
to its default value."
|
|
::= { cOpticalMonitorMIBGroups 10 }
|
|
|
|
END
|