mibs/MIBS/cisco/CISCOSB-LLDP-MIB
2023-12-05 12:25:34 +01:00

1128 lines
41 KiB
Plaintext

CISCOSB-LLDP-MIB DEFINITIONS ::= BEGIN
-- Title: CISCOSB LLDP ROS
-- Private LLDP MIB
-- Version: 7.42
-- Date: 12 Dec 2005
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32, Unsigned32,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TruthValue, RowStatus, MacAddress
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
switch001, rndNotifications
FROM CISCOSB-MIB
LldpPortList, LldpPortNumber, LldpManAddress, lldpRemEntry, lldpPortConfigEntry
FROM LLDP-MIB
PortList
FROM Q-BRIDGE-MIB
Dscp
FROM DIFFSERV-DSCP-TC
AddressFamilyNumbers
FROM IANA-ADDRESS-FAMILY-NUMBERS-MIB
lldpRemTimeMark, lldpRemLocalPortNum, lldpRemIndex
FROM LLDP-MIB
LldpXMedCapabilities
FROM LLDP-EXT-MED-MIB
rndErrorDesc, rndErrorSeverity
FROM CISCOSB-DEVICEPARAMS-MIB
lldpV2LocPortIfIndex, lldpV2RemLocalIfIndex
FROM LLDP-V2-MIB
InetAddressType, InetAddress, InetVersion
FROM INET-ADDRESS-MIB;
rlLldp MODULE-IDENTITY
LAST-UPDATED "202105190000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Postal: 170 West Tasman Drive
San Jose , CA 95134-1706
USA
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
DESCRIPTION
"This private MIB module adds MIBs to LLDP (Link Layer Discovery Protocol)."
REVISION "202105190000Z"
DESCRIPTION
"Initial revision."
::= { switch001 110 }
rlLldpObjects OBJECT IDENTIFIER ::= { rlLldp 1 }
rlLldpConfig OBJECT IDENTIFIER ::= { rlLldpObjects 1 }
rlLldpXMedConfig OBJECT IDENTIFIER ::= { rlLldpObjects 2 }
rlLldpTLVsTxOverload OBJECT IDENTIFIER ::= { rlLldpObjects 3 }
rlLldpRemStatus OBJECT IDENTIFIER ::= { rlLldpObjects 4 }
rlLldpLocalSystemData OBJECT IDENTIFIER ::= { rlLldpObjects 5 }
rlLldpRemoteSystemsData OBJECT IDENTIFIER ::= { rlLldpObjects 6 }
rlLldpV2Config OBJECT IDENTIFIER ::= { rlLldpObjects 7 }
PolicyNumber ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"Policy Number in the Media Policy Container.
Policy numbers should be in the range of 1 and 32768 since 8 policies
can be configured for each particular port and the number of ports range is
1 to 4096."
SYNTAX Integer32(1..32768)
-- Policy Application Type Textual Convention
PolicyContainerAppType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The media type that defines the primary function of the
application for the policy advertised by an endpoint.
A value of voice(1) indicates that the media type defining
a primary function of the application for the policy advertised on
the local port is voice.
A value of voiceSignaling(3) indicates that the media type
defining a primary function of the application for the policy
advertised on the local port is voice signaling.
A value of guestVoice(4) indicates that the media type
Defining a primary function of the application for the policy
advertised on the local port is guest voice.
A value of guestVoiceSignaling(5) indicates that the media
type defining a primary function of the application for the policy
advertised on the local port is guest voice signaling.
A value of softPhoneVoice(6) indicates that the media type
Defining a primary function of the application for the policy
advertised on the local port is softphone voice.
A value of videoConferencing(7) indicates that the media
type defining a primary function of the application for the policy
advertised on the local port is voice.
A value of streamingVideo(8) indicates that the media type
defining a primary function of the application for the policy
advertised on the local port is streaming video.
A value of videoSignaling(2) indicates that the media type
defining a primary function of the application for the policy
advertised on the local port is video signaling."
SYNTAX INTEGER {
unknown(0),
voice(1),
voiceSignaling(2),
guestVoice(3),
guestVoiceSignaling(4),
softPhoneVoice(5),
videoconferencing(6),
streamingVideo(7),
videoSignaling(8)
}
PolicyAppVoiceUpdateMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION ""
SYNTAX INTEGER {
manual(0),
auto(1)
}
------------------------------------------------------------------------------
-- Local Device Configuration 'rlLldpConfig OBJECT IDENTIFIER ::= { rlLldpObjects 1 }'
------------------------------------------------------------------------------
rlLldpEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this variable to 'true' will globally enable the LLDP feature
(both transmit and receive functionalities). Setting this variable
to 'false' will globally disable the LLDP feature. Thus, the
administratively desired status of a local port is determined by
both this variable and the MIB lldpPortConfigAdminStatus."
::= { rlLldpConfig 1 }
rlLldpClearRx OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set of ports that are identified by a PortList, in which
each port is represented as a bit.
Clears the Rx information about the remote agents accordingly to the
specified PortList.
The default value for rlLldpClearRx object is an empty binary string,
which means no ports are specified to be cleared from the Rx Info.
This object behaviors as an event (write-only) than
reading this object always results in an Empty Port List of length zero."
REFERENCE
""
DEFVAL { ''H } -- empty octet string
::= { rlLldpConfig 2 }
rlLldpDuMode OBJECT-TYPE
SYNTAX INTEGER {
filtering(1),
flooding(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action with LLDPDU upon globally disabled LLDP.
If the associated rlLldpDuMode object has a value of
'filtering(1)', then received frames are containing LLDPDU
will be dropped.
If the associated rlLldpDuMode object has a value of
'flooding(2)', then received frames are containing LLDPDU
will flood all active ports."
REFERENCE
"Cisco LLDP System Specifications"
DEFVAL { filtering }
::= { rlLldpConfig 3 }
rlLldpAutoAdvLocPortManAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlLldpAutoAdvLocPortManAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains automaticaly selected management address,
advertised on the local port."
REFERENCE
"Cisco LLDP"
::= { rlLldpConfig 4 }
rlLldpAutoAdvLocPortManAddrEntry OBJECT-TYPE
SYNTAX RlLldpAutoAdvLocPortManAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a local port, which advertises the Management
address automatically. Entry also included an interface number, on
which the Management address is assigned.
Each management address should have distinct 'management address
type' (rlLldpAutoAdvManAddrSubtype) and 'management address'
(rlLldpAutoAdvManAddr)."
INDEX { rlLldpAutoAdvLocPortNum }
::= { rlLldpAutoAdvLocPortManAddrTable 1 }
RlLldpAutoAdvLocPortManAddrEntry ::= SEQUENCE {
rlLldpAutoAdvLocPortNum LldpPortNumber,
rlLldpAutoAdvManAddrOwnerIfId Integer32,
rlLldpAutoAdvManAddrNone TruthValue,
rlLldpAutoAdvManAddrSubtype AddressFamilyNumbers,
rlLldpAutoAdvManAddr LldpManAddress,
rlLldpAutoAdvPortsStatus RowStatus
}
rlLldpAutoAdvLocPortNum OBJECT-TYPE
SYNTAX LldpPortNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index value used to identify the port component
(contained in the local chassis with the LLDP agent)
associated with this entry.
The value of this object is used as a port index to the
rlLldpAutoAdvLocPortManAddrTable."
::= { rlLldpAutoAdvLocPortManAddrEntry 1 }
rlLldpAutoAdvManAddrOwnerIfId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The integer value is used to identify the interface number
(port, trunk or vlan). The management address, automatically
advertised from associated 'rlLldpAutoAdvLocPortNum'local port is
assigned to mentioned 'rlLldpAutoAdvManAddrOwnerIfId' interface.
In case of 0 the management address is automatically calculated
without care to the ifIndex it was defined on."
DEFVAL { 0 }
::= { rlLldpAutoAdvLocPortManAddrEntry 2 }
rlLldpAutoAdvManAddrNone OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value of 'true' indicates that the any management address hasn't advertised
by the local port. Moreover, the configuration of automatic management address
advertisment is disabled.
A value of 'false' indicates that the configuration of automatic management address
advertisment is enabled."
DEFVAL { false }
::= { rlLldpAutoAdvLocPortManAddrEntry 3 }
rlLldpAutoAdvManAddrSubtype OBJECT-TYPE
SYNTAX AddressFamilyNumbers
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of management address identifier encoding used in
the associated 'rlLldpAutoAdvManAddr' object."
::= { rlLldpAutoAdvLocPortManAddrEntry 4 }
rlLldpAutoAdvManAddr OBJECT-TYPE
SYNTAX LldpManAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The string value used to identify the management address is
automaticaly advertised by local port, and assigned on the
associated 'rlLldpAutoAdvManAddrOwnerIfId' interface."
::= { rlLldpAutoAdvLocPortManAddrEntry 5 }
rlLldpAutoAdvPortsStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The row status variable, used according to
row installation and removal conventions."
::= { rlLldpAutoAdvLocPortManAddrEntry 6 }
rlLldpChassisIdSubtype OBJECT-TYPE
SYNTAX INTEGER {
macAddress(4),
local(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of encoding used to identify the chassis
associated with the local system."
REFERENCE
"IEEE 802.1AB-2004 9.5.2.2"
DEFVAL { macAddress }
::= { rlLldpConfig 5 }
rlLldpPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlLldpPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LLDP configuration information that controls the transmission of
non-standard TLVs on LLDP transmission capable ports.
This configuration object augments the lldpPortConfigEntry of
the LLDP-MIB, therefore it is only present along with the port
configuration defined by the associated lldpPortConfigEntry entry."
::= { rlLldpConfig 6 }
rlLldpPortConfigEntry OBJECT-TYPE
SYNTAX RlLldpPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in rlLldpConfigTable. Augment the lldpPortConfigEntry."
AUGMENTS { lldpPortConfigEntry }
::= { rlLldpPortConfigTable 1 }
RlLldpPortConfigEntry ::= SEQUENCE {
rlLldpPortConfig4wireTxEnable TruthValue,
rlLldpPortConfigAdvManAddrMode INTEGER,
rlLldpPortConfigAutoAdvManAddrOwnerIfId Integer32
}
rlLldpPortConfig4wireTxEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The rlLldpPortConfigTLVsTxEnable, which is defined as
a truth value and configured by the network management,
determines whether the 4-wire-poe TLV is allowed on a given LLDP
transmission capable port."
DEFVAL { false }
::= { rlLldpPortConfigEntry 1 }
rlLldpPortConfigAdvManAddrMode OBJECT-TYPE
SYNTAX INTEGER {
manual (0),
none (1),
auto (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value of 'true' indicates that management address TLV does not been advertised
by the local port. Moreover, the configuration of automatic management address
advertisment is disabled.
A value of 'false' indicates that management address being advertised,
either by automatic mechanism or by user-defined management address."
DEFVAL { 0 }
::= { rlLldpPortConfigEntry 2 }
rlLldpPortConfigAutoAdvManAddrOwnerIfId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The integer value is used to identify the interface number
(port, trunk or vlan) that the port will advertise its management addresses.
Value 0 means that the management address will be taken from the port that advertise."
DEFVAL { 0 }
::= { rlLldpPortConfigEntry 3 }
rlLldpClearGlobalStatistics OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An action scalar. Clear LLDP Global statistics counters.
The value in the scalar is not relevant."
::= { rlLldpConfig 7 }
rlLldpClearPortStatistics OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set of ports that are identified by a PortList, in which
each port is represented as a bit.
Clears the LLDP port staistics information accordingly to the
specified PortList.
The default value for rlLldpClearPortlStatistics object is an empty binary string,
which means no ports are specified to be cleared.
This object behaviors as an event (write-only) than
reading this object always results in an Empty Port List of length zero."
DEFVAL { ''H } -- empty octet string
::= { rlLldpConfig 8 }
------------------------------------------------------------------------------
-- LLDP-MED - Local Device Configuration
------------------------------------------------------------------------------
---
--- rlLldpXMedLocMediaPolicyContainerTable: Local Media Policy Container
--- Configuration Table
---
---
rlLldpXMedLocMediaPolicyContainerTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlLldpXMedLocMediaPolicyContainerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per policy number
of media policy container configuration."
::= { rlLldpXMedConfig 1 }
rlLldpXMedLocMediaPolicyContainerEntry OBJECT-TYPE
SYNTAX RlLldpXMedLocMediaPolicyContainerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration of a particular policy in the media policy container."
INDEX { rlLldpXMedLocMediaPolicyContainerIndex }
::= { rlLldpXMedLocMediaPolicyContainerTable 1 }
RlLldpXMedLocMediaPolicyContainerEntry ::= SEQUENCE {
rlLldpXMedLocMediaPolicyContainerIndex PolicyNumber,
rlLldpXMedLocMediaPolicyContainerAppType PolicyContainerAppType,
rlLldpXMedLocMediaPolicyContainerVlanID Integer32,
rlLldpXMedLocMediaPolicyContainerPriority Integer32,
rlLldpXMedLocMediaPolicyContainerDscp Dscp,
rlLldpXMedLocMediaPolicyContainerUnknown TruthValue,
rlLldpXMedLocMediaPolicyContainerTagged TruthValue,
rlLldpXMedLocMediaPolicyContainerPorts PortList,
rlLldpXMedLocMediaPolicyContainerRowStatus RowStatus
}
rlLldpXMedLocMediaPolicyContainerIndex OBJECT-TYPE
SYNTAX PolicyNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index value used to identify the Media Policy
associated with this entry.
The value of this object is used as a policy number index to the
rlLldpXMedLocMediaPolicyContainerTable."
::= { rlLldpXMedLocMediaPolicyContainerEntry 1 }
rlLldpXMedLocMediaPolicyContainerAppType OBJECT-TYPE
SYNTAX PolicyContainerAppType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The media type that defines the primary function of the
application for the policy advertised by an endpoint."
REFERENCE
"ANSI/TIA-1057, Section 10.2.3.1"
::= { rlLldpXMedLocMediaPolicyContainerEntry 2 }
rlLldpXMedLocMediaPolicyContainerVlanID OBJECT-TYPE
SYNTAX Integer32 (0|1..4094|4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An extension of the VLAN Identifier for the port,
as defined in IEEE 802.1P-1998.
A value of 1 through 4094 is used to define a valid PVID.
A value of 0 shall be used if the device is using priority tagged
frames, meaning that only the 802.1p priority level is significant
and the default VID of the ingress port is being used instead.
A value of 4095 is reserved for implementation use."
REFERENCE
" ANSI/TIA-1057, Section 10.2.3.5"
DEFVAL { 0 }
::= { rlLldpXMedLocMediaPolicyContainerEntry 3 }
rlLldpXMedLocMediaPolicyContainerPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the value of the 802.1p priority
which is associated with the given port on the
local system."
REFERENCE
" ANSI/TIA-1057, Section 10.2.3.6 "
DEFVAL { 0 }
::= { rlLldpXMedLocMediaPolicyContainerEntry 4 }
rlLldpXMedLocMediaPolicyContainerDscp OBJECT-TYPE
SYNTAX Dscp
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the value of the Differentiated Service
Code Point (DSCP) as defined in IETF RFC 2474 and RFC 2475
which is associated with the given port on the local system."
REFERENCE
" ANSI/TIA-1057, Section 10.2.3.7"
DEFVAL { 0 }
::= { rlLldpXMedLocMediaPolicyContainerEntry 5 }
rlLldpXMedLocMediaPolicyContainerUnknown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value of 'true' indicates that the
network policy for the specified application type is
currently unknown. In this case, the VLAN ID, the
layer 2 priority and the DSCP value fields are ignored.
A value of 'false' indicates that this network policy
is defined "
REFERENCE
" ANSI/TIA-1057, Section 10.2.3.2"
DEFVAL { false }
::= { rlLldpXMedLocMediaPolicyContainerEntry 6 }
rlLldpXMedLocMediaPolicyContainerTagged OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value of 'true' indicates that the application is using a
tagged VLAN.
A value of 'false' indicates that for the specific application
the device either is using an untagged VLAN or does not
support port based VLAN operation. In this case, both the
VLAN ID and the Layer 2 priority fields are ignored and
only the DSCP value has relevance "
REFERENCE
" ANSI/TIA-1057, Section 10.2.3.3"
DEFVAL { false }
::= { rlLldpXMedLocMediaPolicyContainerEntry 7 }
rlLldpXMedLocMediaPolicyContainerPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A set of ports that are identified by a PortList, in which
each port is represented as a bit. The local Media Policy Number
will be associated with (or attached to) the ports specified at
the rlLldpXMedLocMediaPolicyContainerPorts.
The default value for rlLldpXMedLocMediaPolicyContainerPorts object
is empty binary string, which means no ports are specified
for advertising indicated management address instance."
REFERENCE
"IEEE 802.1AB-2004 10.2.1.1"
DEFVAL { ''H } -- empty binary string
::= { rlLldpXMedLocMediaPolicyContainerEntry 8 }
rlLldpXMedLocMediaPolicyContainerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The row status variable, used according to
row installation and removal conventions."
::= { rlLldpXMedLocMediaPolicyContainerEntry 9 }
------------------------------------------------------------------------------
-- LLDP - MED Local Voice VLAN update mode
------------------------------------------------------------------------------
rlLldpXMedNetPolVoiceUpdateMode OBJECT-TYPE
SYNTAX PolicyAppVoiceUpdateMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { rlLldpXMedConfig 2 }
------------------------------------------------------------------------------
-- LLDP - MED Operational Status (whether the interface Tx MED TLVs)
-- Private MIB which enhance lldpXMedPortConfigTable - 'rlLldpXMedPortConfigTbale'
------------------------------------------------------------------------------
rlLldpXMedPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlLldpXMedPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per policy number
of media policy container configuration."
::= { rlLldpXMedConfig 3 }
rlLldpXMedPortConfigEntry OBJECT-TYPE
SYNTAX RlLldpXMedPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration of a particular policy in the media policy container."
INDEX { lldpPortConfigPortNum }
::= { rlLldpXMedPortConfigTable 1 }
RlLldpXMedPortConfigEntry ::= SEQUENCE {
rlLldpXMedPortConfigTxOperStatus INTEGER }
rlLldpXMedPortConfigTxOperStatus OBJECT-TYPE
SYNTAX INTEGER {
not-relevant (0),
enabled (1),
disabled (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field indicates whether this interface is operational
transmitted LLDP MED TLVs.
To transmit MED TLVs, the interface must be MED enabled and must be connected to an LLDP-MED device.
The switch waits for the LLDP-MED device to advertise its information before the switch transmits its own LLDP-MED TLVs,
at which point the operational status becomes enabled"
DEFVAL { 0 }
::= { rlLldpXMedPortConfigEntry 1 }
------------------------------------------------------------------------------
-- LLDP - TX TLV overloading 'rlLldpTLVsTxOverload'
------------------------------------------------------------------------------
rlLldpTLVsTxOverloadingTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlLldpTLVsTxOverloadingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that show the which of the LLDP TLVs are not transmitted
on individual ports due to insufficient room in the frame
and the size of each TLV."
::= { rlLldpTLVsTxOverload 1 }
rlLldpTLVsTxOverloadingEntry OBJECT-TYPE
SYNTAX RlLldpTLVsTxOverloadingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LLDP TX overloading information that shows the
transmission of TLVs on LLDP transmission capable ports."
INDEX { rlLldpTxOverloadingPortNum,
rlLldpTxOverloadingIndex }
::= { rlLldpTLVsTxOverloadingTable 1 }
RlLldpTLVsTxOverloadingEntry ::= SEQUENCE {
rlLldpTxOverloadingPortNum LldpPortNumber,
rlLldpTxOverloadingIndex Unsigned32,
rlLldpTxOverloadingGroupId INTEGER,
rlLldpTLVsTxSize Unsigned32,
rlLldpTLVsTxGroupOverloading TruthValue,
rlLldpTLVsTxLeftSize Unsigned32
}
rlLldpTxOverloadingPortNum OBJECT-TYPE
SYNTAX LldpPortNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The value of this object is used as a port index to the
TLVs TX overloading Table ."
::= { rlLldpTLVsTxOverloadingEntry 1 }
rlLldpTxOverloadingIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The sequence number of the group into sent LLDP PPDU starting from 1."
::= { rlLldpTLVsTxOverloadingEntry 2 }
rlLldpTxOverloadingGroupId OBJECT-TYPE
SYNTAX INTEGER {
-- LLDP mandatory TLVs
mandatory(1),
optional(2),
-- LLDP MED
medCap(3),
medLocation(4),
medNetPolicy(5),
medPoe(6),
-- LLDP MED - Inventory
medInventory(7),
-- 802.3 TLVs
xDot3(8),
-- 802.1 TLVs
xDot1(9),
-- DCBX TLVs
dcbx(10),
-- Cisco TLVs
cisco(11)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the TLVs groups.
A value of mandatory(1) defines LLDP mandatory TLVs group
A value of optinal(2) defines LLDP optional TLVs group
A value of medCap(3) defines LLDP MED - Capabilities group
A value of medLocation(4) defines LLDP MED - Location group
A value of medNetPolicy(5) defines LLDP MED - Network Policy group
A value of medPoe(6) defines LLDP MED - Extended Power via MDI group
A value of medInventory(7) defines LLDP MED - Inventory group
A value of Xdot3(8) defines 802.3 TLVs group
A value of Xdot1(9) defines 802.1 TLVs group "
::= { rlLldpTLVsTxOverloadingEntry 3 }
rlLldpTLVsTxSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The size of the TLV in Bytes."
::= { rlLldpTLVsTxOverloadingEntry 4 }
rlLldpTLVsTxGroupOverloading OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Boolean Flag, When TRUE indicating that LLDP TLVs were overloaded
and the value of left size is negative"
::= { rlLldpTLVsTxOverloadingEntry 5 }
rlLldpTLVsTxLeftSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The size in Bytes of the available space left in the LLDPDU after adding the TLVs group.
In case the Overloading Flag is TRUE, there not enough space in the LLDPDU for the TLVs group
and this is the size of the additional scpace that required for the TLVs group"
::= { rlLldpTLVsTxOverloadingEntry 6 }
------------------------------------------------------------------------------
-- LLDP - TX TLV overloading Size
------------------------------------------------------------------------------
rlLldpTLVsTxOverloadingSizeTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlLldpTLVsTxOverloadingSizeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that show the total size of the all TLVs
and the LLDPDU free size ."
::= { rlLldpTLVsTxOverload 2 }
rlLldpTLVsTxOverloadingSizeEntry OBJECT-TYPE
SYNTAX RlLldpTLVsTxOverloadingSizeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LLDP TX overloading information"
INDEX { rlLldpTxOverloadingPortNum }
::= { rlLldpTLVsTxOverloadingSizeTable 1 }
RlLldpTLVsTxOverloadingSizeEntry ::= SEQUENCE {
-- LLDP Total and Left Size
rlLldpTotalTLVsTxSize Unsigned32,
rlLldpTLVsTxOverloading TruthValue,
rlLldpLeftTLVsTxSize Unsigned32
}
rlLldpTotalTLVsTxSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The Total size of all TLVs group in Bytes."
::= { rlLldpTLVsTxOverloadingSizeEntry 2 }
rlLldpTLVsTxOverloading OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Boolean Flag, When TRUE indicating that LLDP TLVs group were overloaded
and the value of left size is negative"
::= { rlLldpTLVsTxOverloadingSizeEntry 3 }
rlLldpLeftTLVsTxSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The size in Bytes of the available space left in the LLDPDU after adding all TLVs group.
In case the Overloading Flag is TRUE, there not enough space in the LLDPDU for all the TLVs group
and this is the size of the additional scpace that required for all the TLVs group"
::= { rlLldpTLVsTxOverloadingSizeEntry 4 }
------------------------------------------------------------------------------
-- LLDP - TX TLV overloading port list
------------------------------------------------------------------------------
rlLldpTLVsTxOverloadingPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port list that represent the overloading state of each port"
::= { rlLldpTLVsTxOverload 3 }
------------------------------------------------------------------------------
-- LLDP - TX TLV overloading trap
------------------------------------------------------------------------------
rlLldpTLVsTxOverloadingStateEnterTrap NOTIFICATION-TYPE
OBJECTS { rndErrorDesc, rndErrorSeverity }
STATUS current
DESCRIPTION
"Informational trap indicating that the port has entered the overloading state."
::= { rndNotifications 209 }
rlLldpTLVsTxOverloadingStateExitTrap NOTIFICATION-TYPE
OBJECTS { rndErrorDesc, rndErrorSeverity }
STATUS current
DESCRIPTION
"Informational trap indicating that the port is no longer in the overloading state.."
::= { rndNotifications 210 }
------------------------------------------------------------------------------
-- LLDP - Remote Time to Live
------------------------------------------------------------------------------
rlLldpRemTtlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlLldpRemTtlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the remote device Time To Live LLDP TLV."
::= { rlLldpRemStatus 1 }
rlLldpRemTtlEntry OBJECT-TYPE
SYNTAX RlLldpRemTtlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LLDP Time To TTL remove TLV.
This uses the key as defind in lldpRemTable of the LLDP-MIB."
INDEX { lldpRemTimeMark,
lldpRemLocalPortNum,
lldpRemIndex }
::= { rlLldpRemTtlTable 1 }
RlLldpRemTtlEntry ::= SEQUENCE {
rlLldpRemTtl Unsigned32
}
rlLldpRemTtl OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the remote device Time To Live LLDP TLV."
::= { rlLldpRemTtlEntry 1 }
------------------------------------------------------------------------------
-- rlLldpLocalSystemData OBJECT IDENTIFIER ::= { rlLldpObjects 5 }
------------------------------------------------------------------------------
------------------------------------------------------------------------------
-- rlLldpLoc4WirePowerTable
------------------------------------------------------------------------------
rlLldpLoc4WirePowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlLldpLoc4WirePowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per port of power ethernet
information "
::= { rlLldpLocalSystemData 1 }
rlLldpLoc4WirePowerEntry OBJECT-TYPE
SYNTAX RlLldpLoc4WirePowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular port component."
INDEX { lldpV2LocPortIfIndex }
::= { rlLldpLoc4WirePowerTable 1 }
RlLldpLoc4WirePowerEntry ::= SEQUENCE {
rlLldpLoc4WirePowerSupported TruthValue,
rlLldpLoc4WirePowerSpPairDetClasReq TruthValue,
rlLldpLoc4WirePowerPdSpPairDesStEn TruthValue,
rlLldpLoc4WirePowerPseSpPairOpStEn TruthValue
}
rlLldpLoc4WirePowerSupported OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { rlLldpLoc4WirePowerEntry 1 }
rlLldpLoc4WirePowerSpPairDetClasReq OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { rlLldpLoc4WirePowerEntry 2 }
rlLldpLoc4WirePowerPdSpPairDesStEn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { rlLldpLoc4WirePowerEntry 3 }
rlLldpLoc4WirePowerPseSpPairOpStEn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { rlLldpLoc4WirePowerEntry 4 }
------------------------------------------------------------------------------
-- rlLldpRemoteSystemsData OBJECT IDENTIFIER ::= { rlLldpObjects 6 }
------------------------------------------------------------------------------
------------------------------------------------------------------------------
-- rlLldpRem4WirePowerTable MIB_rlLldpRem4WirePowerEntry_CNS
------------------------------------------------------------------------------
rlLldpRem4WirePowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlLldpRem4WirePowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per port of power ethernet
information "
::= { rlLldpRemoteSystemsData 1 }
rlLldpRem4WirePowerEntry OBJECT-TYPE
SYNTAX RlLldpRem4WirePowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular port component."
INDEX {
lldpRemTimeMark,
lldpRemLocalPortNum,
lldpRemIndex
}
::= { rlLldpRem4WirePowerTable 1 }
RlLldpRem4WirePowerEntry ::= SEQUENCE {
rlLldpRem4WirePowerSupported TruthValue,
rlLldpRem4WirePowerSpPairDetClasReq TruthValue,
rlLldpRem4WirePowerPdSpPairDesStEn TruthValue,
rlLldpRem4WirePowerPseSpPairOpStEn TruthValue
}
rlLldpRem4WirePowerSupported OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { rlLldpRem4WirePowerEntry 1 }
rlLldpRem4WirePowerSpPairDetClasReq OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { rlLldpRem4WirePowerEntry 2 }
rlLldpRem4WirePowerPdSpPairDesStEn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { rlLldpRem4WirePowerEntry 3 }
rlLldpRem4WirePowerPseSpPairOpStEn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { rlLldpRem4WirePowerEntry 4 }
------------------------------------------------------------------------------
-- rlLldpRemTable Augment to lldpRemTable
------------------------------------------------------------------------------
rlLldpRemTable OBJECT-TYPE
SYNTAX SEQUENCE OF RllldpRemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is AUGMENT for lldpRemTable. Each entry consists Source MAC address."
::= { rlLldpRemoteSystemsData 2 }
rlLldpRemEntry OBJECT-TYPE
SYNTAX RllldpRemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry that consists source MAC address of the remote station."
AUGMENTS { lldpRemEntry }
::= { rlLldpRemTable 1 }
RllldpRemEntry ::= SEQUENCE {
rlLldpRemSrcMacAddr MacAddress,
rlLldpRemActiveStation TruthValue
}
rlLldpRemSrcMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Source MAC address of the remote station."
::= { rlLldpRemEntry 1 }
rlLldpRemActiveStation OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the entry is active (the port is up and LLDP Rx is enabled)."
::= { rlLldpRemEntry 2 }
------------------------------------------------------------------------------
-- rlLldpV2Config OBJECT IDENTIFIER ::= { rlLldpObjects 7 }
------------------------------------------------------------------------------
rlLldpV2AutoAdvLocPortManAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlLldpV2AutoAdvLocPortManAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains automaticaly selected management address,
advertised on the local port."
REFERENCE
"Marvell LLDP"
::= { rlLldpV2Config 1 }
rlLldpV2AutoAdvLocPortManAddrEntry OBJECT-TYPE
SYNTAX RlLldpV2AutoAdvLocPortManAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a local port, which advertises the Management
address automatically. Entry also included an interface number, on
which the Management address is assigned.
Each management address should have distinct 'management address
type' (rlLldpAutoAdvManAddrSubtype) and 'management address'
(rlLldpAutoAdvManAddr)."
INDEX { rlLldpV2AutoAdvLocPortNum, rlLldpV2AutoAdvManAddrType, rlLldpV2AutoAdvManAddr}
::= { rlLldpV2AutoAdvLocPortManAddrTable 1 }
RlLldpV2AutoAdvLocPortManAddrEntry ::= SEQUENCE {
rlLldpV2AutoAdvLocPortNum LldpPortNumber,
rlLldpV2AutoAdvManAddrType InetAddressType,
rlLldpV2AutoAdvManAddr InetAddress,
rlLldpV2AutoAdvManAddrOwnerIfId Integer32
}
rlLldpV2AutoAdvLocPortNum OBJECT-TYPE
SYNTAX LldpPortNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index value used to identify the port component
(contained in the local chassis with the LLDP agent)
associated with this entry.
The value of this object is used as a port index to the
rlLldpAutoAdvLocPortManAddrTable."
::= { rlLldpV2AutoAdvLocPortManAddrEntry 1 }
rlLldpV2AutoAdvManAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The type of management address identifier encoding used in
the associated 'rlLldpAutoAdvManAddr' object."
::= { rlLldpV2AutoAdvLocPortManAddrEntry 2 }
rlLldpV2AutoAdvManAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The string value used to identify the management address is
automatically advertised by local port, and assigned on the
associated 'rlLldpAutoAdvManAddrOwnerIfId' interface."
::= { rlLldpV2AutoAdvLocPortManAddrEntry 3 }
rlLldpV2AutoAdvManAddrOwnerIfId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The integer value is used to identify the interface number
(port, trunk or vlan). The management address, automatically
advertised from associated 'rlLldpAutoAdvLocPortNum' local port is
assigned to mentioned 'rlLldpAutoAdvManAddrOwnerIfId' interface."
::= { rlLldpV2AutoAdvLocPortManAddrEntry 4 }
END