mibs/MIBS/cisco/CISCOSB-RLINVENTORYENT-MIB
2023-12-05 12:25:34 +01:00

113 lines
3.6 KiB
Plaintext

CISCOSB-RLINVENTORYENT-MIB DEFINITIONS ::= BEGIN
IMPORTS
switch001 FROM CISCOSB-MIB
Unsigned32, OBJECT-TYPE FROM SNMPv2-SMI
DisplayString FROM RFC1213-MIB;
UnitIfindexType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Unit or ifindex type."
SYNTAX INTEGER {
unit(0),
ifindex(1)
}
rlInventoryEntTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlInventoryEntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table that contains INVENTORY entities in the system."
::= { switch001 217 }
rlInventoryEntEntry OBJECT-TYPE
SYNTAX RlInventoryEntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry (conceptual row) in the rlInventoryEnvTable."
INDEX { rlInventoryEntUnitOrIfindex ,rlInventoryEntUnitIfindexID }
::= { rlInventoryEntTable 1 }
RlInventoryEntEntry::= SEQUENCE {
rlInventoryEntUnitOrIfindex UnitIfindexType,
rlInventoryEntUnitIfindexID Unsigned32,
rlInventoryEntVendorID DisplayString,
rlInventoryEntPID DisplayString,
rlInventoryEntName DisplayString,
rlInventoryEntDescription DisplayString,
rlInventoryEntSerialNumber DisplayString,
rlInventoryEntUnitNum Unsigned32
}
rlInventoryEntUnitOrIfindex OBJECT-TYPE
SYNTAX UnitIfindexType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "this field will be equal to zero if this is a unit else 1 if this is a port."
::= { rlInventoryEntEntry 1 }
rlInventoryEntUnitIfindexID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "if rlInventoryEntUnitOrIfindex = 0 this field contain the unit number else if rlInventoryEntUnitOrIfindex = 1
This field contain the if_index number."
::= { rlInventoryEntEntry 2 }
rlInventoryEntVendorID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Vendor identification"
::= { rlInventoryEntEntry 3 }
rlInventoryEntPID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Physical identification"
::= { rlInventoryEntEntry 4}
rlInventoryEntName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Unit number of interface name"
::= { rlInventoryEntEntry 5 }
rlInventoryEntDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Description of the entity"
::= { rlInventoryEntEntry 6}
rlInventoryEntSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The serial number of the interface or unit."
::= { rlInventoryEntEntry 7 }
rlInventoryEntUnitNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "if rlInventoryEntUnitOrIfindex = 1 this field contain the unit number that associated to this port"
::= { rlInventoryEntEntry 8 }
END