CISCOSB-SENSORENTMIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
rlEnv
|
|
FROM CISCOSB-HWENVIROMENT
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Integer32, Unsigned32, mib-2
|
|
FROM SNMPv2-SMI
|
|
entPhySensorEntry
|
|
FROM ENTITY-SENSOR-MIB
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION, TimeStamp
|
|
FROM SNMPv2-TC
|
|
entPhysicalIndex, entityPhysicalGroup
|
|
FROM ENTITY-MIB
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
EntitySensorValue
|
|
FROM ENTITY-SENSOR-MIB;
|
|
|
|
rlSensor MODULE-IDENTITY
|
|
LAST-UPDATED "200309210000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
|
|
CONTACT-INFO
|
|
"Postal: 170 West Tasman Drive
|
|
San Jose , CA 95134-1706
|
|
USA
|
|
|
|
|
|
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
|
|
|
|
DESCRIPTION
|
|
"The private MIB module definition for sensors in CISCOSB devices."
|
|
REVISION "200309210000Z"
|
|
DESCRIPTION
|
|
"ADDED this MODULE-IDENTITY clause."
|
|
::= { rlEnv 4 }
|
|
|
|
rlEntPhySensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlEntPhySensorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The addition to the table of sensors maintained by the environmental
|
|
monitor."
|
|
::= { rlEnv 3 }
|
|
|
|
rlEntPhySensorEntry OBJECT-TYPE
|
|
SYNTAX RlEntPhySensorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An additon to the entry in the sensor table, representing the
|
|
maximum/minimum values for the sensor associated."
|
|
AUGMENTS {entPhySensorEntry}
|
|
::= { rlEntPhySensorTable 1 }
|
|
|
|
RlEntPhySensorEntry ::=
|
|
SEQUENCE {
|
|
rlEnvPhySensorMinValue EntitySensorValue,
|
|
rlEnvPhySensorMaxValue EntitySensorValue,
|
|
rlEnvPhySensorTestValue EntitySensorValue,
|
|
rlEnvPhySensorLocation SnmpAdminString
|
|
}
|
|
|
|
rlEnvPhySensorMinValue OBJECT-TYPE
|
|
SYNTAX EntitySensorValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value for the Sensor being instrumented."
|
|
::= { rlEntPhySensorEntry 1 }
|
|
|
|
rlEnvPhySensorMaxValue OBJECT-TYPE
|
|
SYNTAX EntitySensorValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value for the Sensor being instrumented."
|
|
::= { rlEntPhySensorEntry 2 }
|
|
|
|
rlEnvPhySensorTestValue OBJECT-TYPE
|
|
SYNTAX EntitySensorValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Test/reference value for the Sensor being instrumented."
|
|
::= { rlEntPhySensorEntry 3 }
|
|
|
|
rlEnvPhySensorLocation OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual description for the Location where the Sensor being instrumented."
|
|
::= { rlEntPhySensorEntry 4 }
|
|
END
|
|
|