CISCOSB-SMARTPORTS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
-- -------------------------------------------------------------
|
|
-- Banner MIB
|
|
-- Title: Cisco Smart Ports Private MIB
|
|
-- This Private MIB manages smart ports macros
|
|
-- Version: 7.47
|
|
-- Date: 30 July 2008
|
|
--
|
|
-- -------------------------------------------------------------
|
|
|
|
IMPORTS
|
|
switch001 FROM CISCOSB-MIB
|
|
TEXTUAL-CONVENTION,DisplayString FROM SNMPv2-TC
|
|
InterfaceIndexOrZero FROM IF-MIB
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
|
EnabledStatus FROM P-BRIDGE-MIB
|
|
RowStatus FROM SNMPv2-TC
|
|
OBJECT-TYPE FROM SNMPv2-SMI;
|
|
|
|
|
|
rlSmartPorts MODULE-IDENTITY
|
|
LAST-UPDATED "200807300000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
|
|
CONTACT-INFO
|
|
"Postal: 170 West Tasman Drive
|
|
San Jose , CA 95134-1706
|
|
USA
|
|
|
|
|
|
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
|
|
|
|
DESCRIPTION
|
|
"The private MIB module definition for Smart Ports -
|
|
provide a convenient way to save and share common configurations.
|
|
Smart Ports group a group of command to be applied on a port or a trunk
|
|
OR on a global configuration context. In addition Smart port
|
|
application provide a database per interface (or global configuration)
|
|
to list applied macros.
|
|
Each smart port macro can either a user-defined or pre-defined."
|
|
REVISION "200807300000Z"
|
|
DESCRIPTION
|
|
"Initial revision."
|
|
::= { switch001 140 }
|
|
|
|
|
|
-- -------------------------------------------------------------
|
|
-- Textual Conventions
|
|
-- -------------------------------------------------------------
|
|
|
|
|
|
MacroType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Smart Ports macro type."
|
|
SYNTAX INTEGER {
|
|
rlSmartPortsMacroInterfaceVendorProvided(1),
|
|
rlSmartPortsMacroGloablVendorProvided(2),
|
|
rlSmartPortsMacroUserCreated(3)
|
|
|
|
}
|
|
|
|
RlSmartPortsMacroName ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Macro name."
|
|
SYNTAX DisplayString(SIZE(1..32))
|
|
|
|
RlSmartPortsMacroNameOrZero ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Macro name."
|
|
SYNTAX DisplayString(SIZE(0..32))
|
|
-- -------------------------------------------------------------
|
|
-- --------- Tables --------------------------------------
|
|
-- -------------------------------------------------------------
|
|
|
|
-- -------------------------------------------------------------
|
|
-- --------- rlSmartPortsMacroManageTable ----------------
|
|
-- -------------------------------------------------------------
|
|
|
|
rlSmartPortsMacroManageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlSmartPortsMacroManageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The table listing available smart ports macros,
|
|
holding:
|
|
macro name
|
|
macro type: user defined,
|
|
CISCOSB provided per interface
|
|
CISCOSB provided globally
|
|
and matches a macro index to be used as identifier in
|
|
rlSmartPortsMacroContentTable where the macro content really IS
|
|
Allow to add/remove user defined macros."
|
|
::= {rlSmartPorts 1 }
|
|
|
|
rlSmartPortsMacroManageEntry OBJECT-TYPE
|
|
SYNTAX RlSmartPortsMacroManageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the rlSmartPortsMacroManageTable."
|
|
INDEX { IMPLIED rlSmartPortsMacroName }
|
|
::= {rlSmartPortsMacroManageTable 1 }
|
|
|
|
RlSmartPortsMacroManageEntry ::= SEQUENCE {
|
|
rlSmartPortsMacroName RlSmartPortsMacroName,
|
|
rlSmartPortsMacroIndex INTEGER,
|
|
rlSmartPortsMacroType MacroType,
|
|
rlSmartPortsMacroStatus RowStatus,
|
|
rlSmartPortsMacroKeywords DisplayString,
|
|
rlSmartPortsMacroDesc1 DisplayString,
|
|
rlSmartPortsMacroDesc2 DisplayString
|
|
}
|
|
|
|
rlSmartPortsMacroName OBJECT-TYPE
|
|
SYNTAX RlSmartPortsMacroName
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Macro name."
|
|
::= { rlSmartPortsMacroManageEntry 1 }
|
|
|
|
rlSmartPortsMacroIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the macro's index.
|
|
An arbitrary incremental Index used as identifier in
|
|
rlSmartPortsMacroContentTable where the macro content really IS."
|
|
::= { rlSmartPortsMacroManageEntry 2 }
|
|
|
|
rlSmartPortsMacroType OBJECT-TYPE
|
|
SYNTAX MacroType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the macro type: user defined,
|
|
CISCOSB provided per interface
|
|
CISCOSB provided globally"
|
|
::= { rlSmartPortsMacroManageEntry 3 }
|
|
|
|
|
|
rlSmartPortsMacroStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of a table entry.
|
|
It is used to delete/Add an entry from this table."
|
|
::= { rlSmartPortsMacroManageEntry 4 }
|
|
|
|
|
|
rlSmartPortsMacroKeywords OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..160))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of Macro Keywords. if there are"
|
|
::= { rlSmartPortsMacroManageEntry 5 }
|
|
|
|
rlSmartPortsMacroDesc1 OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..160))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of Macro descriptions. if there are"
|
|
::= { rlSmartPortsMacroManageEntry 6 }
|
|
|
|
rlSmartPortsMacroDesc2 OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..160))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"continue List of Macro descriptions. if there are"
|
|
::= { rlSmartPortsMacroManageEntry 7 }
|
|
|
|
|
|
|
|
-- -------------------------------------------------------------
|
|
-- --------- rlSmartPortsMacroContentTable ----------------
|
|
-- -------------------------------------------------------------
|
|
|
|
rlSmartPortsMacroContentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlSmartPortsMacroContentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table holds smart ports macro's content.
|
|
Entries are allowed to be added ONLY on macro indexes that
|
|
1) has a corresponding entry in rlSmartPortsMacroManageTable
|
|
2) has rlSmartPortsMacroType = rlSmartPortsMacroUserCreated"
|
|
::= {rlSmartPorts 2 }
|
|
|
|
rlSmartPortsMacroContentEntry OBJECT-TYPE
|
|
SYNTAX RlSmartPortsMacroContentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the elSmartPortsMacroManageTable."
|
|
INDEX { rlSmartPortsMacroIndex,rlSmartPortsMacroOctetIndex}
|
|
::= {rlSmartPortsMacroContentTable 1 }
|
|
|
|
RlSmartPortsMacroContentEntry ::= SEQUENCE {
|
|
rlSmartPortsMacroOctetIndex INTEGER (1..19),
|
|
rlSmartPortsMacroText SnmpAdminString
|
|
|
|
}
|
|
|
|
rlSmartPortsMacroOctetIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..19)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the line number in the macro's content text.
|
|
To allow full macro size of 3k = 19 * 160 = 3040"
|
|
::= { rlSmartPortsMacroContentEntry 1 }
|
|
|
|
rlSmartPortsMacroText OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Macro content."
|
|
::= { rlSmartPortsMacroContentEntry 2 }
|
|
|
|
-- -------------------------------------------------------------
|
|
-- --------- rlSmartPortsMacroDescriptionTable ----------------
|
|
-- -------------------------------------------------------------
|
|
|
|
|
|
rlSmartPortsMacroDescriptionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlSmartPortsMacroDescriptionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table holds smart ports macro's name
|
|
globally (rlSmartPortsMacroDescriptionIndex == 0)
|
|
interface (port or trunk)."
|
|
::= {rlSmartPorts 3 }
|
|
|
|
rlSmartPortsMacroDescriptionEntry OBJECT-TYPE
|
|
SYNTAX RlSmartPortsMacroDescriptionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the rlSmartPortsMacroInterfaceTable."
|
|
INDEX { rlSmartPortsMacroDescriptionIndex}
|
|
::= {rlSmartPortsMacroDescriptionTable 1 }
|
|
|
|
RlSmartPortsMacroDescriptionEntry ::= SEQUENCE {
|
|
rlSmartPortsMacroDescriptionIndex InterfaceIndexOrZero,
|
|
rlSmartPortsMacroDescriptionText SnmpAdminString,
|
|
rlSmartPortsMacroDescriptionStatus RowStatus
|
|
}
|
|
|
|
rlSmartPortsMacroDescriptionIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies global configuration when equals 0 OR
|
|
local port or trunk on which the user saved Macro's name."
|
|
::= { rlSmartPortsMacroDescriptionEntry 1 }
|
|
|
|
rlSmartPortsMacroDescriptionText OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Macro name."
|
|
::= { rlSmartPortsMacroDescriptionEntry 2 }
|
|
|
|
rlSmartPortsMacroDescriptionStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of a table entry.
|
|
It is used to delete/Add an entry from this table."
|
|
::= { rlSmartPortsMacroDescriptionEntry 3 }
|
|
-- -------------------------------------------------------------
|
|
-- --------- rlSmartPortsFreeIndexes ----------------
|
|
-- -------------------------------------------------------------
|
|
rlSmartPortsFreeIndexes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns free index to set in rlSmartPortsMacroIndex when macro is added."
|
|
::= { rlSmartPorts 4 }
|
|
|
|
-- -------------------------------------------------------------
|
|
-- --------- rlSmartPorts Diagnostics ---------------------
|
|
-- -------------------------------------------------------------
|
|
rlSmartPortsDiagMacroName OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In case the last macro had failed you will get this name from the
|
|
specific terminal you had used ."
|
|
::= { rlSmartPorts 5 }
|
|
|
|
rlSmartPortsDiagLineNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In case the last macro had failed you will get i'ts line number from
|
|
specific terminal you had used ."
|
|
::= { rlSmartPorts 6 }
|
|
|
|
rlSmartPortsDiagCommandLine OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In case the last macro had failed you will get i'ts command line number
|
|
from specific terminal you had used ."
|
|
::= { rlSmartPorts 7 }
|
|
|
|
|
|
rlSmartPortsCondenseMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"disabled - in macro description macro such as x no_x will be removed
|
|
enabled - in macro description macro such as x no_x will not be removed
|
|
when condense mode is enabled (by default) each time a macro with the name
|
|
no_x is applied and prior to that a macro x was applied , they will be removed
|
|
from the list...
|
|
|
|
"
|
|
|
|
DEFVAL {enabled}
|
|
::= { rlSmartPorts 8 }
|
|
|
|
|
|
|
|
|
|
END
|