mibs/MIBS/cisco/DIFF-SERV-MIB
2023-12-05 12:25:34 +01:00

1526 lines
53 KiB
Plaintext

DIFF-SERV-MIB DEFINITIONS ::= BEGIN
IMPORTS
rlExperience FROM CISCOSB-MIB
Unsigned32, Counter32, Counter64,
OBJECT-TYPE, MODULE-IDENTITY,
zeroDotZero, mib-2 FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus,
RowPointer, TestAndIncr FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
ifIndex FROM IF-MIB
-- InetEndpointType, InetEndpoint FROM INET-ENDPOINT-MIB;
InetAddressType, InetAddress FROM INET-ADDRESS-MIB;
diffServMib MODULE-IDENTITY
LAST-UPDATED "9907190100Z" -- Mon Jul 19 01:00:00 PDT 1999
ORGANIZATION "Cisco Systems"
CONTACT-INFO
" Fred Baker
Postal: 519 Lado Drive
Santa Barbara, California 93111
Tel: +1 (408)526-4257
FAX: +1 (805)681-0115
E-mail: fred@cisco.com
Kwok Ho Chan
Postal: 600 Technology Park Drive
Billerica, Massachusetts 01821, USA
Tel: +1 (978)288-8175
E-mail: khchan@nortelnetworks.com
Andrew Smith
Postal: 3585 Monroe St.
Santa Clara, California 95051
Tel: +1 (408) 579 2821
FAX: +1 (408) 579 3000
E-mail: andrew@extremenetworks.com"
DESCRIPTION
"This MIB defines the objects necessary to manage a
device that uses the Differentiated Services
Architecture described in RFC 2475."
REVISION "9907190100Z" -- Mon Jul 19 01:00:00 PDT 1999
DESCRIPTION
"Initial version, published as RFC xxxx."
-- ::= { mib-2 12345 } ## anybody who uses this
-- ## unassigned number
-- ## deserves the wrath of IANA
::= { rlExperience 1 }
diffServObjects OBJECT IDENTIFIER ::= { diffServMib 1 }
diffServTables OBJECT IDENTIFIER ::= { diffServMib 2 }
diffServMIBConformance OBJECT IDENTIFIER ::= { diffServMib 3 }
-- The tools necessary to perform basic Behavior
-- Aggregate Classification
--
Dscp ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"The code point used for discriminating a traffic
stream."
SYNTAX INTEGER (0..63)
diffServAggregateTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiffServAggregateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The 'Aggregate' Table enumerates Behavior Aggregate
classifiers (DSCPs) that a system may identify traffic
using."
::= { diffServTables 1 }
diffServAggregateEntry OBJECT-TYPE
SYNTAX DiffServAggregateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An 'aggregate' entry describes a single BA
classifier."
INDEX { diffServAggregateDSCP }
::= { diffServAggregateTable 1 }
DiffServAggregateEntry ::= SEQUENCE {
diffServAggregateDSCP Dscp
}
diffServAggregateDSCP OBJECT-TYPE
SYNTAX Dscp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the Differentiated Services Code Point (DSCP)
for the classifier. This object is only meant to be
pointed to by a RowPointer from other tables, such as
the diffServClassifierMatchObject, and is not actually
configured or changed."
::= { diffServAggregateEntry 1 }
-- The tools for MultiField Classification.
--
-- This textual convention has no effect on either the syntax
-- nor the semantics of any managed object. Objects defined
-- using this convention are always encoded by means of the
-- rules that define their primitive type.
--
MFClassifierL4Port ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A value indicating a Layer-4 protocol port number."
SYNTAX INTEGER (0..65535)
-- This object allows a configuring system to obtain a
-- unique value for diffServClassifierNumber for purposes of
-- configuration.
diffServMFClassifierUnique OBJECT-TYPE
SYNTAX TestAndIncr
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The diffServMFClassifierUnique object yields a
unique new value for diffServMFClassifierIndex when read and
subsequently set. This value must be tested for
uniqueness."
::= { diffServObjects 1 }
diffServMFClassifierTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiffServMFClassifierEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of MF (IP 6-tuple multi-field) classifier
entries that a system may use to identify traffic."
::= { diffServTables 2 }
diffServMFClassifierEntry OBJECT-TYPE
SYNTAX DiffServMFClassifierEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A multi-field classifier entry describes a single MF
classifier."
INDEX { diffServMFClassifierIndex }
::= { diffServMFClassifierTable 1 }
DiffServMFClassifierEntry ::= SEQUENCE {
diffServMFClassifierIndex INTEGER,
diffServMFClassifierAddrType InetAddressType,
diffServMFClassifierDstAddr InetAddress,
diffServMFClassifierDstAddrMask InetAddress,
diffServMFClassifierSrcAddr InetAddress,
diffServMFClassifierSrcAddrMask InetAddress,
diffServMFClassifierDscp INTEGER,
diffServMFClassifierProtocol INTEGER,
diffServMFClassifierDstL4PortMin MFClassifierL4Port,
diffServMFClassifierDstL4PortMax MFClassifierL4Port,
diffServMFClassifierSrcL4PortMin MFClassifierL4Port,
diffServMFClassifierSrcL4PortMax MFClassifierL4Port,
diffServMFClassifierStatus RowStatus
}
diffServMFClassifierIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
-- MAX-ACCESS not-accessible
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a unique index for the classifier. This object
is meant to be pointed to by a RowPointer from other
tables, such as the diffServClassifierMatchObject."
::= { diffServMFClassifierEntry 1 }
diffServMFClassifierAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of IP address used by this classifier entry."
::= { diffServMFClassifierEntry 2 }
diffServMFClassifierDstAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP address to match against the packet's
destination IP address."
::= { diffServMFClassifierEntry 3 }
diffServMFClassifierDstAddrMask OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A mask for the matching of the destination IP address.
A zero bit in the mask means that the corresponding bit
in the address always matches."
::= { diffServMFClassifierEntry 4 }
diffServMFClassifierSrcAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP address to match against the source IP address
of each packet."
::= { diffServMFClassifierEntry 5 }
diffServMFClassifierSrcAddrMask OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A mask for the matching of the source IP address."
::= { diffServMFClassifierEntry 6 }
diffServMFClassifierDscp OBJECT-TYPE
SYNTAX INTEGER (-1 | 0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value that the DSCP in the packet must have to
match this entry. A value of -1 indicates that a
specific DSCP value has not been defined and thus all
DSCP values are considered a match."
::= { diffServMFClassifierEntry 7 }
diffServMFClassifierProtocol OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP protocol to match against the IPv4 protocol
number in the packet. A value of zero means match all."
::= { diffServMFClassifierEntry 8 }
diffServMFClassifierDstL4PortMin OBJECT-TYPE
SYNTAX MFClassifierL4Port
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The minimum value that the layer-4 destination port
number in the packet must have in order to match this
classifier entry."
::= { diffServMFClassifierEntry 9 }
diffServMFClassifierDstL4PortMax OBJECT-TYPE
SYNTAX MFClassifierL4Port
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum value that the layer-4 destination port
number in the packet must have in order to match this
classifier entry. This value must be equal to or
greater that the value specified for this entry in
diffServMFClassifierDstL4PortMin."
::= { diffServMFClassifierEntry 10 }
diffServMFClassifierSrcL4PortMin OBJECT-TYPE
SYNTAX MFClassifierL4Port
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The minimum value that the layer-4 source port number
in the packet must have in order to match this
classifier entry."
::= { diffServMFClassifierEntry 11 }
diffServMFClassifierSrcL4PortMax OBJECT-TYPE
SYNTAX MFClassifierL4Port
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum value that the layer-4 source port number
in the packet must have in oder to match this
classifier entry. This value must be equal to or
greater that the value specified for this entry in
dsSixTupleIpSrcL4PortMin."
::= { diffServMFClassifierEntry 12 }
diffServMFClassifierStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This indicates the status of this classifier entry."
::= { diffServMFClassifierEntry 13 }
-- This object allows a configuring system to obtain a
-- unique value for diffServClassifierNumber for purposes of
-- configuration
diffServClassifierUnique OBJECT-TYPE
SYNTAX TestAndIncr
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The diffServClassifierUnique object yields a unique
new value for diffServClassifierNumber when read and
subsequently set. This value must be tested for
uniqueness."
::= { diffServObjects 2 }
-- The Classifier Table allows us to enumerate the
-- relationship between arbitrary classifiers and
-- the meters which apply to classified streams.
diffServClassifierTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiffServClassifierEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The classifier table enumerates specific classifiers
that a system may apply, including Differentiated
Services Code Points (DSCPs) and Multi-field
discriminators such as {Source IP Address, Destination
IP Address, IP Protocol, Source TCP/UDP Port,
Destination TCP/UDP Port)."
::= { diffServTables 3 }
diffServClassifierEntry OBJECT-TYPE
SYNTAX DiffServClassifierEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the classifier table describes a single
classifier."
INDEX { ifIndex, diffServInterfaceDirection,
diffServClassifierNumber }
::= { diffServClassifierTable 1 }
DiffServClassifierEntry ::= SEQUENCE {
diffServInterfaceDirection INTEGER,
diffServClassifierNumber INTEGER,
diffServClassifierMatchObject RowPointer,
diffServClassifierNext RowPointer,
diffServClassifierSequence Unsigned32,
diffServClassifierConfigType INTEGER,
diffServClassifierConfigTypeInfo OCTET STRING,
diffServClassifierStatus RowStatus
}
diffServInterfaceDirection OBJECT-TYPE
SYNTAX INTEGER {
inbound(1), -- ingress interface
outbound(2) -- egress interface
}
-- MAX-ACCESS not-accessible
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the direction for this entry on the
interface. 'inbound' traffic is operated on during
receipt, while 'outbound' traffic is operated on prior
to transmission."
::= { diffServClassifierEntry 1 }
diffServClassifierNumber OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
-- MAX-ACCESS not-accessible
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"diffServClassifierNumber enumerates the classifier
entry."
::= { diffServClassifierEntry 2 }
diffServClassifierMatchObject OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A pointer to the row that describes the applicable
classifier. An obvious choice would be the
diffServAggregateEntry for a given DSCP, but other
choices include tables describing any classifier that
may be of interest. If the row pointed to does not
exist, the classifier is ignored.
The NULL OID zeroDotZero is interpreted to match
anything not matched by another classifier."
DEFVAL { zeroDotZero }
::= { diffServClassifierEntry 3 }
diffServClassifierNext OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The 'next' variable selects the appropriate meter or
action to apply to this class of traffic."
::= { diffServClassifierEntry 4 }
diffServClassifierSequence OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The sequence in which classifiers are applied, in
ascending order. Classifiers with the same sequence
number must be unambiguous. Classifiers with different
sequence numbers may overlap in their ranges, with the
understanding that the first applied classifier to
match a packet is taken."
DEFVAL { 0 }
::= { diffServClassifierEntry 5 }
diffServClassifierConfigType OBJECT-TYPE
SYNTAX INTEGER {
other (0),
mib (1), -- Configured via MIB
pib (2), -- Configured via PIB
bgp (3) -- Configured via BGP
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to indicate how the classifer is configured."
::= { diffServClassifierEntry 6 }
diffServClassifierConfigTypeInfo OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Additional information associated with how the
classifier is configured."
::= { diffServClassifierEntry 7 }
diffServClassifierStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The RowStatus variable controls the activation,
deactivation, or deletion of a classifier. Any writable
variable may be modified whether the row is active or
notInService."
::= { diffServClassifierEntry 8 }
-- This object allows a configuring system to obtain a
-- unique value for diffServClassifierNumber for purposes of
-- configuration
diffServTBMeterUnique OBJECT-TYPE
SYNTAX TestAndIncr
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The diffServTBMeterUnique object yieldiffServ a unique
new value for diffServTBMeterNumber when read and
subsequently set. This value must be tested for
uniqueness."
::= { diffServObjects 3 }
-- The Meter Table allows us to enumerate the
-- relationship between meters and the actions, other
-- meters, and queues that result from them.
diffServTBMeterTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiffServTBMeterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Meter Table enumerates specific token bucket
meters that a system may use to police a stream of
classified traffic. Such a stream may include a single
micro-flow, all traffic from a given source to a given
destination, all traffic conforming to a single
classifier, or any other cut of the traffic, including
all of it.
Note that the conceptual model requires all traffic to
pass through one or more meters, and that the last
meter configured in such a sequence must always
conform.
Counters in this table start counting on creation of
the meter that specifies their existence."
::= { diffServTables 4 }
diffServTBMeterEntry OBJECT-TYPE
SYNTAX DiffServTBMeterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the meter table describes a single token
bucket meter. Note that a meter has exactly one rate,
defined as the burst size each time interval. Multiple
meters may be cascaded should a multi-rate token bucket
be needed in a given Per-Hop Behavior. An example of
such a PHB is AF."
INDEX { ifIndex, diffServInterfaceDirection,
diffServTBMeterNumber }
::= { diffServTBMeterTable 1 }
DiffServTBMeterEntry ::= SEQUENCE {
diffServTBMeterNumber INTEGER,
diffServTBMeterInterval Unsigned32,
diffServTBMeterBurstSize Unsigned32,
diffServTBMeterFailNext RowPointer,
diffServTBMeterSucceedNext RowPointer,
diffServTBMeterStatus RowStatus
}
diffServTBMeterNumber OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The number of the meter, for reference from the
classifier or in cascade from another meter."
::= { diffServTBMeterEntry 1 }
diffServTBMeterInterval OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of microseconds in the token bucket
interval for this meter. Note that implementations
frequently do not keep time in microseconds internally,
so in implementation the effect of this value must be
approximated."
::= { diffServTBMeterEntry 2 }
diffServTBMeterBurstSize OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of bytes in a single transmission burst.
The rate at which the metered traffic may run is one
burst per interval. Note that if multiple meters are
cascaded onto one PHB, such as in AF, their intervals
must be equal, and the peak rate of the data stream is
the sum of their intervals per interval."
::= { diffServTBMeterEntry 3 }
diffServTBMeterFailNext OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If the traffic does not conform to the meter, the next
meter or action to enquire of."
::= { diffServTBMeterEntry 4 }
diffServTBMeterSucceedNext OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The 'Succeed Next' pointer selects which action or
queue on the interface that to be used with the
message. Incoming traffic may use the value zeroDotZero
in this variable to indicate that no queuing on receipt
occurs. Incoming interfaces generally use queuing
either to divert routing traffic for speedier
processing during a flap, or for shaping purposes."
DEFVAL { zeroDotZero }
::= { diffServTBMeterEntry 5 }
diffServTBMeterStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The RowStatus variable controls the activation,
deactivation, or deletion of a meter. Any writable
variable may be modified whether the row is active or
notInService."
::= { diffServTBMeterEntry 6 }
-- This object allows a configuring system to obtain a
-- unique value for diffServActionNumber for purposes of
-- configuration
diffServActionUnique OBJECT-TYPE
SYNTAX TestAndIncr
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The diffServActionUnique object yields a unique new
value for diffServActionNumber when read and
subsequently set. This value must be tested for
uniqueness."
::= { diffServObjects 4 }
-- The Meter Table allows us to enumerate the
-- relationship between meters and the actions, other meters,
-- and queues that result from them.
diffServActionTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiffServActionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Action Table enumerates specific apply to a stream
of classified traffic. Such a stream may include a
single micro-flow, all traffic from a given source to a
given destination, all traffic conforming to a single
classifier, or any other cut of the traffic, including
all of it.
Counters in this table start counting on creation of
the action that specifies their existence."
::= { diffServTables 5 }
diffServActionEntry OBJECT-TYPE
SYNTAX DiffServActionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the action table describes the actions
applied to traffic conforming to a given meter."
INDEX { ifIndex, diffServInterfaceDirection,
diffServActionNumber }
::= { diffServActionTable 1 }
DiffServActionEntry ::= SEQUENCE {
diffServActionNumber INTEGER,
diffServActionNext RowPointer,
diffServActionDSCP Dscp,
diffServActionMinThreshold Unsigned32,
diffServActionMaxThreshold Unsigned32,
diffServActionDropPolicy INTEGER,
diffServActionHCConformingPackets Counter64,
diffServActionConformingPackets Counter32,
diffServActionHCConformingOctets Counter64,
diffServActionConformingOctets Counter32,
diffServActionTailDrops Counter32,
diffServActionHCTailDrops Counter64,
diffServActionRandomDrops Counter32,
diffServActionHCRandomDrops Counter64,
diffServActionStatus RowStatus
}
diffServActionNumber OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
-- MAX-ACCESS not-accessible
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the meter, for reference from the
classifier or in cascade from another meter."
::= { diffServActionEntry 1 }
diffServActionNext OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The 'Next' pointer selects which queue or Traffic
Control Block on the interface. Incoming traffic may
use the value zeroDotZero in this variable to indicate
that no queuing on receipt occurs. Incoming interfaces
generally use queuing either to divert routing traffic
for speedier processing during a flap, or for shaping
purposes."
DEFVAL { zeroDotZero }
::= { diffServActionEntry 2 }
diffServActionDSCP OBJECT-TYPE
SYNTAX Dscp
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The DSCP that traffic conforming to this classifier
and this meter is remarked with. Note that if the
classifier is working from the same DSCP value, no
effective change in the DSCP results.
Differentiated Services may result in packet remarking
both on ingress to a network and on egress, and it is
quite possible that ingress and egress would occur in
the same router."
::= { diffServActionEntry 3 }
diffServActionMinThreshold OBJECT-TYPE
SYNTAX Unsigned32
UNITS "packets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The min-threshold is the queue depth that a random
drop process will seek to manage the queue's depth to.
This object is in the action table rather than the
queue table because Differentiated Services PHBs, such
as the Assured Service, permit differently classified
traffic to have different drop parameters even though
they occupy the same queue."
::= { diffServActionEntry 4 }
diffServActionMaxThreshold OBJECT-TYPE
SYNTAX Unsigned32
UNITS "packets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The max-threshold is the maximum permissible queue
depth. In tail drop scenarios, the queue will drop if a
packet is presented to it and it is instantaneously
full by this measure. In random drop scenarios, the
queue will drop if a packet is presented to it and the
average queue depth exceeds the max-threshold.
This object is in the action table rather than the
queue table because Differentiated Services PHBs, such
as the Assured Service, permit differently classified
traffic to have different drop parameters even though
they occupy the same queue."
::= { diffServActionEntry 5 }
diffServActionDropPolicy OBJECT-TYPE
SYNTAX INTEGER {
other(1),
alwaysDrop (2), -- Disallowed traffic
tailDrop(3), -- Fixed Queue Size
randomDrop(4) -- RED w/thresholds
-- per class
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The drop policy applied to traffic."
::= { diffServActionEntry 6 }
diffServActionHCConformingPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Packets conforming to this meter. This
object is used on high speed interfaces.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { diffServActionEntry 7 }
diffServActionConformingPackets OBJECT-TYPE
SYNTAX Counter32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Packets conforming to this meter. This
object may be used on low speed interfaces, and
represents the least significant 32 bits of
diffServActionHCConformingPackets.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { diffServActionEntry 8 }
diffServActionHCConformingOctets OBJECT-TYPE
SYNTAX Counter64
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets conforming to this meter. This
object is used on high speed interfaces.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { diffServActionEntry 9 }
diffServActionConformingOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets conforming to this meter. This
object may be used on low speed interfaces, and
represents the least significant 32 bits of
diffServActionHCConformingOctets.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { diffServActionEntry 10 }
diffServActionTailDrops OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets conforming to this classifier
and meter that have been dropped because either the
meter always drops, or the queue's depth exceeds the
max-threshold value. On high speed devices, this
object implements the least significant 32 bits of
diffServActionHCTailDrops .
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { diffServActionEntry 11 }
diffServActionHCTailDrops OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets conforming to this classifier
and meter that have been dropped because either the
meter always drops, or the queue's depth exceeds the
max-threshold value. This object should be used on
high speed interfaces.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { diffServActionEntry 12 }
diffServActionRandomDrops OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets conforming to this classifier
and meter that have been dropped by a random drop
process because the queue is over-full. On high speed
lines, this object reflects the least significant 32
bits of diffServActionHCRandomDrops.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { diffServActionEntry 13 }
diffServActionHCRandomDrops OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets conforming to this classifier
and meter that have been dropped by a random drop
process because the queue is over-full. This object is
used on high speed lines.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime."
::= { diffServActionEntry 14 }
diffServActionStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The RowStatus variable controls the activation,
deactivation, or deletion of a meter. Any writable
variable may be modified whether the row is active or
notInService."
::= { diffServActionEntry 15 }
-- This object allows a configuring system to obtain a
-- unique value for diffServQueueNumber for purposes of
-- configuration
diffServQueueUnique OBJECT-TYPE
SYNTAX TestAndIncr
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The diffServQueueUnique object yields a unique new
value for diffServQueueNumber when read and
subsequently set. This value must be tested for
uniqueness."
::= { diffServObjects 5 }
-- The Queue Table allows us to describe queues
diffServQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiffServQueueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Queue Table enumerates the queues on an interface.
Queues are used to store traffic during intervals when
the arrival rate exceeds the departure rate for a class
of traffic. Because some PHBs indicate that the use of
a priority queue may be advisable, each queue in this
system is seen as having a priority. Those queues that
share the same priority operate in what may externally
appear to be a Weighted Round Robin manner, and preempt
the traffic belonging to any lower priority. For this
reason, it is strongly urged that traffic placed into
prioritized queues be strongly policed to avoid traffic
lockout.
Queues in this table also have a minimum and a maximum
rate. When a maximum rate is specified, the queue acts
as a shaper if it has sufficient traffic and capacity
is available. If it is a minimum rate, then the weight
in the WRR is effectively set to this rate divided by
the sum of the rates of queues on the interface,
guaranteeing it at least that throughput rate. If it is
a maximum rate, the queue operates as a shaper. A
shaper potentially reduces the rate of traffic through
it to the indicated rate, and minimizes variations in
rate."
::= { diffServTables 6 }
diffServQueueEntry OBJECT-TYPE
SYNTAX DiffServQueueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Queue Table describes a single FIFO
queue."
INDEX { ifIndex, diffServInterfaceDirection,
diffServQueueNumber }
::= { diffServQueueTable 1 }
DiffServQueueEntry ::= SEQUENCE {
diffServQueueNumber INTEGER,
diffServQueueMinimumRate Unsigned32,
diffServQueueMaximumRate Unsigned32,
diffServQueuePriority Unsigned32,
diffServQueueNextTCB RowPointer,
diffServQueueOccupancyWeight Unsigned32,
diffServQueueStatus RowStatus
}
diffServQueueNumber OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
-- MAX-ACCESS not-accessible
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the queue."
::= { diffServQueueEntry 1 }
diffServQueueMinimumRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "KBPS"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The rate of the queue, in kilobits per second (KBPS).
This unit is chosen because interfaces exist at the
time of this writing which exceed the number of bits
per second which may be represented in a 32 bit number.
If the value is zero, then there is effectively no
minimum rate. If the value is non-zero, the queue set
will seek to assure this class of traffic at least this
rate."
::= { diffServQueueEntry 2 }
diffServQueueMaximumRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "KBPS"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The rate of the queue, in kilobits per second (KBPS).
This unit is chosen because interfaces exist at the
time of this writing which exceed the number of bits
per second which may be represented in a 32 bit number.
If the value is zero, then there is effectively no
maximum rate. If the value is non-zero, the queue set
will seek to assure this class of traffic at most this
rate."
::= { diffServQueueEntry 3 }
diffServQueuePriority OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The priority of the queue. If multiple queues exist on
the same interface at the same priority, they are
effectively given Weighted Round Robin service. If
multiple priorities are configured on an interface,
traffic with a numerically higher priority number is
deemed to have higher priority than other traffic, and
is preemptively serviced."
::= { diffServQueueEntry 4 }
diffServQueueNextTCB OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The 'Next' pointer selects the successor TCB on the
interface. Incoming traffic may use the value
zeroDotZero in this variable to indicate that the
packet is now to be routed; outbound traffic may use
the same value to indicate that no subsequent queuing
applies. Ingress interfaces generally use queuing
either to divert routing traffic for speedier
processing during a flap, or for shaping purposes."
DEFVAL { zeroDotZero }
::= { diffServQueueEntry 5 }
diffServQueueOccupancyWeight OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The amount, in the form of a factor, that the current,
actual queue occupancy should influence the averaged
queue occupancy. The averaged queue occupancy can be
used for comparison to configured drop thresholds in
RED or RED-like dropper implementations. Larger the
weight, the greater the instantaneous queue occupancy
influences the averaged queue occupancy. Usually,
dramatic changes in the instantaneous queue occupancy
is the result of bursty input streams. Notice this
numeric attribute is divided by 10,000 to get the
effective fractional factor used in the actual
calculations."
::= { diffServQueueEntry 6 }
diffServQueueStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The RowStatus variable controls the activation,
deactivation, or deletion of a queue. Any writable
variable may be modified whether the row is active or
notInService."
::= { diffServQueueEntry 7 }
-- MIB Compliance statements. Three variations of
-- compliance are described, for optical, LAN, and low speed
-- interfaces. The difference is the implementation of
-- diffServActionHCConformingOctets
-- and diffServActionHCConformingPackets
--diffServMIBCompliances OBJECT IDENTIFIER ::= { diffServMIBConformance 1 }
--diffServMIBGroups OBJECT IDENTIFIER ::= { diffServMIBConformance 2 }
--
--diffServMIBCompliance MODULE-COMPLIANCE
-- STATUS current
-- DESCRIPTION
-- "This MIB may be implemented as a read-only or as a
-- read-create MIB. As a result, it may be used for
-- monitoring or for configuration.
-- Standard compliance implies that the implementation
-- complies for interfaces for which an interface's octet
-- counter might wrap at most once an hour, which by the
-- IFMIB's convention applies to interfaces under 20 MBPS.
-- It thus applies to any device which might implement a
-- low speed serial line, Ethernet, Token Ring."
-- MODULE ## This Module
-- MANDATORY-GROUPS { diffServMIBClassifierGroup, diffServMIBMeterGroup,
-- diffServMIBQueueGroup, diffServMIBActionGroup
--
-- ## note that diffServMIBHCCounterGroup is
-- ## mandatory for medium and high speed interfaces
--
-- ## note that diffServMIBVHCCounterGroup is
-- ## mandatory for high speed interfaces
--
-- ## note that the diffServMIBStaticGroup is
-- ## mandatory for implementations that implement a
-- ## read-write or read-create mode.
-- }
--
-- GROUP diffServMIBHCCounterGroup
-- DESCRIPTION
-- "This group is mandatory for those network interfaces
-- for which the value of the corresponding instance of
-- ifSpeed is greater than 20,000,000 bits/second."
--
-- GROUP diffServMIBVHCCounterGroup
-- DESCRIPTION
-- "This group is mandatory for those network interfaces
-- for which the value of the corresponding instance of
-- ifSpeed is greater than 650,000,000 bits/second."
--
-- OBJECT diffServClassifierMatchObject
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServClassifierNext
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServClassifierSequence
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServClassifierStatus
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterInterval
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterBurstSize
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterFailNext
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterSucceedNext
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterStatus
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionNext
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionDSCP
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionMinThreshold
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionMaxThreshold
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionDropPolicy
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionStatus
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueueMinimumRate
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueueMaximumRate
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueuePriority
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueueNextTCB
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueueStatus
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
-- ::= { diffServMIBCompliances 1 }
--
--diffServMIBVHCCompliance MODULE-COMPLIANCE
-- STATUS current
-- DESCRIPTION
-- "This MIB may be implemented as a read-only or as a
-- read-create MIB. As a result, it may be used for
-- monitoring or for configuration.
-- Very High Speed compliance implies that the
-- implementation complies for interfaces for which an
-- interface's packet or octet counters might wrap more
-- than once an hour, which by the IFMIB's convention
-- applies to interfaces over 650 MBPS, or OC-12."
-- MODULE ## This Module
-- MANDATORY-GROUPS { diffServMIBClassifierGroup, diffServMIBMeterGroup,
-- diffServMIBQueueGroup, diffServMIBHCCounterGroup,
-- diffServMIBVHCCounterGroup, diffServMIBActionGroup
--
-- ## note that the diffServMIBStaticGroup is
-- ## mandatory for implementations that implement a
-- ## read-write or read-create mode.
-- }
--
--
-- OBJECT diffServClassifierMatchObject
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServClassifierNext
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServClassifierSequence
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServClassifierStatus
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterInterval
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterBurstSize
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterFailNext
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterSucceedNext
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterStatus
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionNext
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionDSCP
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionMinThreshold
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionMaxThreshold
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionDropPolicy
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionStatus
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueueMinimumRate
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueueMaximumRate
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueuePriority
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueueNextTCB
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueueStatus
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
-- ::= { diffServMIBCompliances 2 }
--
--diffServMIBHCCompliance MODULE-COMPLIANCE
-- STATUS current
-- DESCRIPTION
-- "This MIB may be implemented as a read-only or as a
-- read-create MIB. As a result, it may be used for
-- monitoring or for configuration.
-- High Speed compliance implies that the implementation
-- complies for interfaces for which an interface's octet
-- counters might wrap more than once an hour, which by
-- the IFMIB's convention applies to interfaces over 20
-- MBPS, but under 650 MBPS. It thus applies to devices
-- which implement a 100 MBPS Ethernet, FDDI, E3, DS3, or
-- SONET/SDH interface up to OC-12."
-- MODULE ## This Module
-- MANDATORY-GROUPS { diffServMIBClassifierGroup, diffServMIBMeterGroup,
-- diffServMIBQueueGroup, diffServMIBHCCounterGroup,
-- diffServMIBActionGroup
--
-- ## note that diffServMIBVHCCounterGroup is
-- ## mandatory for high speed interfaces
--
-- ## note that the diffServMIBStaticGroup is
-- ## mandatory for implementations that implement a
-- ## read-write or read-create mode.
-- }
--
-- GROUP diffServMIBVHCCounterGroup
-- DESCRIPTION
-- "This group is mandatory for those network interfaces
-- for which the value of the corresponding instance of
-- ifSpeed is greater than 650,000,000 bits/second."
--
-- OBJECT diffServClassifierMatchObject
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServClassifierNext
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServClassifierSequence
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServClassifierStatus
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterInterval
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterBurstSize
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterFailNext
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterSucceedNext
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServTBMeterStatus
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionNext
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionDSCP
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionMinThreshold
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionMaxThreshold
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionDropPolicy
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServActionStatus
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueueMinimumRate
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueueMaximumRate
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueuePriority
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueueNextTCB
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
--
-- OBJECT diffServQueueStatus
-- MIN-ACCESS read-only
-- DESCRIPTION
-- "Write access is not required."
-- ::= { diffServMIBCompliances 3 }
--
--diffServMIBClassifierGroup OBJECT-GROUP
-- OBJECTS { diffServAggregateDSCP,
-- diffServClassifierMatchObject,
-- diffServClassifierNext,
-- diffServClassifierSequence,
-- diffServClassifierStatus
-- }
-- STATUS current
-- DESCRIPTION
-- "The Classifier Group defines the MIB Objects that
-- describe a classifier."
-- ::= { diffServMIBGroups 1 }
--
--diffServMIBMeterGroup OBJECT-GROUP
-- OBJECTS { diffServTBMeterInterval, diffServTBMeterBurstSize,
-- diffServTBMeterSucceedNext, diffServTBMeterFailNext,
-- diffServTBMeterStatus
-- }
-- STATUS current
-- DESCRIPTION
-- "The Meter Group defines the objects used in describing
-- a meter."
-- ::= { diffServMIBGroups 2 }
--
--diffServMIBActionGroup OBJECT-GROUP
-- OBJECTS { diffServActionDropPolicy,
-- diffServActionRandomDrops,
-- diffServActionTailDrops,
-- diffServActionMinThreshold,
-- diffServActionMaxThreshold, diffServActionDSCP,
-- diffServActionNext,
-- diffServActionConformingPackets,
-- diffServActionConformingOctets,
-- diffServActionStatus
-- }
-- STATUS current
-- DESCRIPTION
-- "The Action Group defines the objects used in
-- describing an action."
-- ::= { diffServMIBGroups 3 }
--
--diffServMIBHCCounterGroup OBJECT-GROUP
-- OBJECTS { diffServActionHCConformingOctets
-- }
-- STATUS current
-- DESCRIPTION
-- "At 20,000,000 bits per second or greater, the number
-- of octets a given class may count can overflow a 32 bit
-- counter in under an hour. Therefore, by convention
-- established in the IFMIB, the 64 bit counter must be
-- implemented as well."
-- ::= { diffServMIBGroups 4 }
--
--diffServMIBVHCCounterGroup OBJECT-GROUP
-- OBJECTS { diffServActionHCConformingPackets,
-- diffServActionHCRandomDrops,
-- diffServActionHCTailDrops
-- }
-- STATUS current
-- DESCRIPTION
-- "At 650,000,000 bits per second or greater, the number
-- of packets a given class may count can overflow a 32
-- bit counter in under an hour. Therefore, by convention
-- established in the IFMIB, the 64 bit counter must be
-- implemented as well."
-- ::= { diffServMIBGroups 5 }
--
--diffServMIBQueueGroup OBJECT-GROUP
-- OBJECTS { diffServQueueMinimumRate,
-- diffServQueueMaximumRate,
-- diffServQueuePriority, diffServQueueStatus,
-- diffServQueueNextTCB
-- }
-- STATUS current
-- DESCRIPTION
-- "The Queue Group contains the objects that describe an
-- interface's queues."
-- ::= { diffServMIBGroups 6 }
--
--diffServMIBStaticGroup OBJECT-GROUP
-- OBJECTS { diffServClassifierUnique, diffServTBMeterUnique,
-- diffServQueueUnique, diffServActionUnique
-- }
-- STATUS current
-- DESCRIPTION
-- "The Static Group contains scalar objects used in
-- creating unique enumerations for classifiers, meters,
-- and queues."
-- ::= { diffServMIBGroups 7 }
END