-- Copyright 2010 Scientific Atlanta, A Cisco Company
-- All Rights Reserved
-- No portions of this material may be reproduced in any
-- form without the written permission of:
-- Scientific Atlanta, A Cisco Company
-- 5030 Sugarloaf Pkwy
-- Lawrenceville, Georgia 30044
--
--**************************************************************************
SA-MTA-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
enterprises,
Integer32,
Unsigned32
FROM SNMPv2-SMI
ifIndex
FROM IF-MIB
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
TruthValue,
DateAndTime
FROM SNMPv2-TC ;
sa OBJECT IDENTIFIER ::= { enterprises 1429 }
saVoip OBJECT IDENTIFIER ::= { sa 78 }
saMta MODULE-IDENTITY
LAST-UPDATED "201611100000Z"
ORGANIZATION "Cisco Inc."
CONTACT-INFO "vveeraga@cisco.com"
DESCRIPTION
"saMtaDevLCSSignalingSupport controls the LCS Signaling."
-- History
REVISION "201611100000Z"
DESCRIPTION
"Initial release of reduced-set module for releases based on BFC 5.7.x."
::= { saVoip 3 }
-- MTA Device
saMtaDevice OBJECT IDENTIFIER ::= { saMta 1 }
saMtaDevOffHookWarnTOBusy OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures whether an endpoint should ring off-hook warning tone.
When this feature is disabled(0), Endpoint should ring off-hook warning tone.
When this feature is enabled(1), Endpoint should ring busy tone instead of off-hook warning tone.
The default value of this object is disabled(0)."
DEFVAL { 0 }
::= { saMtaDevice 61 }
-- ==========================
-- ENDPOINT TABLE STARTS HERE
-- ==========================
saMtaEndPointTable OBJECT-TYPE
SYNTAX SEQUENCE OF SaMtaEndPointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes the MTA EndPoint
Volume configuration. "
::= { saMta 2 }
saMtaEndPointEntry OBJECT-TYPE
SYNTAX SaMtaEndPointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" List of attributes for a single MTA endpoint interface."
INDEX { ifIndex }
::= { saMtaEndPointTable 1 }
SaMtaEndPointEntry ::= SEQUENCE {
saMtaEndPntHookFlashMinTime INTEGER,
saMtaEndPntHookFlashMaxTime INTEGER,
saMtaEndPntStatePhysical INTEGER,
saMtaEndPntStateLogical INTEGER
}
saMtaEndPntHookFlashMinTime OBJECT-TYPE
SYNTAX INTEGER (40..2000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shortest onhook time at which hook-flash event will be detected, in miliseconds.
Breaks in loop current with shorter duration are assumed to be noise and are ignored."
::= { saMtaEndPointEntry 1 }
saMtaEndPntHookFlashMaxTime OBJECT-TYPE
SYNTAX INTEGER (100..2000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Longest onhook time at which hook-flash event will be detected,
in miliseconds. If onhook time is longer then saMtaHookFlashMaxTime,
hang up event will be detected."
::= { saMtaEndPointEntry 2 }
saMtaEndPntStatePhysical OBJECT-TYPE
SYNTAX INTEGER {
onHook(1),
offHook(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the physical state of the end point.
1: No phones attached or one or more phones are attached and
on-hook
2: One or more phones are attached and off-hook"
::= { saMtaEndPointEntry 6 }
saMtaEndPntStateLogical OBJECT-TYPE
SYNTAX INTEGER {
connectedIdle(1),
disconnected(2),
inCallVoice(3),
inCallData(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the logical state of the end point.
1: endpoint is connected to CMS and not in call
2: endpoint is not connected to CMS
3: endpoint is in voice mode call
4: endpoint is in data mode (fax/modem) call"
::= { saMtaEndPointEntry 7 }
END