1710 lines
51 KiB
Plaintext
1710 lines
51 KiB
Plaintext
|
|
MAS-MIB-SMIV2-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Counter32, Gauge32, Integer32, IpAddress, NOTIFICATION-TYPE,OBJECT-TYPE, TimeTicks, enterprises, MODULE-IDENTITY, OBJECT-IDENTITY
|
|
FROM SNMPv2-SMI
|
|
Ipv6Address
|
|
FROM IPV6-TC
|
|
InetAddressType, InetAddress
|
|
FROM INET-ADDRESS-MIB;
|
|
|
|
netScaler MODULE-IDENTITY
|
|
LAST-UPDATED "201312050000Z"
|
|
ORGANIZATION "Citrix Systems, Inc."
|
|
CONTACT-INFO "Citrix Technical Assistance Center
|
|
Postal: Citrix Systems, Inc.
|
|
851 West Cypress Creek Road
|
|
Fort Lauderdale, Florida 33309
|
|
United States
|
|
Tel: +1-800-4-CITRIX (+1-800-424-8749)
|
|
E-mail: customercare@citrix.com"
|
|
DESCRIPTION "The enterprise specific MIB for Citrix Application Delivery Management."
|
|
::= { enterprises 5951 }
|
|
|
|
|
|
masRoot OBJECT IDENTIFIER
|
|
::= { netScaler 7}
|
|
|
|
masEventGroup OBJECT IDENTIFIER
|
|
::= { masRoot 1 }
|
|
|
|
|
|
systemGroup OBJECT IDENTIFIER
|
|
::= { masRoot 2 }
|
|
|
|
systemPlatform OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Platform"
|
|
::= { systemGroup 1 }
|
|
|
|
systemProduct OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Product Name"
|
|
::= { systemGroup 2 }
|
|
|
|
systemBuildNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Build Number"
|
|
::= { systemGroup 3 }
|
|
|
|
systemIPAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of systemIPAddress"
|
|
::= { systemGroup 4 }
|
|
systemIPAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Address"
|
|
::= { systemGroup 5 }
|
|
|
|
systemNetmaskType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of systemNetmask"
|
|
::= { systemGroup 6 }
|
|
systemNetmask OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Netmask"
|
|
::= { systemGroup 7 }
|
|
|
|
systemGatewayType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of systemGateway"
|
|
::= { systemGroup 8 }
|
|
systemGateway OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway "
|
|
::= { systemGroup 9 }
|
|
|
|
systemDnsType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of systemDns"
|
|
::= { systemGroup 10 }
|
|
systemDns OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS Server"
|
|
::= { systemGroup 11 }
|
|
|
|
systemSysId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System Id"
|
|
::= { systemGroup 12 }
|
|
|
|
systemSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial Number"
|
|
::= { systemGroup 13 }
|
|
|
|
systemCurrentTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current Time"
|
|
::= { systemGroup 14 }
|
|
|
|
systemUptime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uptime"
|
|
::= { systemGroup 15 }
|
|
|
|
systemBiosVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BIOS Version"
|
|
::= { systemGroup 16 }
|
|
|
|
systemCustomID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Custom identification number for appliance"
|
|
::= { systemGroup 17 }
|
|
|
|
systemCpuUsage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU Usage (%)"
|
|
::= { systemGroup 18 }
|
|
|
|
systemMemoryUsage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Memory Usage (%)"
|
|
::= { systemGroup 19 }
|
|
|
|
systemDiskUsage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Disk Usage (%)"
|
|
::= { systemGroup 20 }
|
|
|
|
|
|
deviceGroup OBJECT IDENTIFIER
|
|
::= { masRoot 3 }
|
|
|
|
netscalerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NetscalerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"netscalertable"
|
|
::= { deviceGroup 2 }
|
|
|
|
netscalerEntry OBJECT-TYPE
|
|
SYNTAX NetscalerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
INDEX { nsIpAddressType, nsIpAddress, nsHostIPAddressType, nsHostIPAddress }
|
|
::= { netscalerTable 1}
|
|
|
|
NetscalerEntry ::= SEQUENCE {
|
|
nsIpAddressType InetAddressType,
|
|
nsIpAddress InetAddress,
|
|
nsHostIPAddressType InetAddressType,
|
|
nsHostIPAddress InetAddress,
|
|
nsProfileName OCTET STRING,
|
|
nsName OCTET STRING,
|
|
nsNetmaskType InetAddressType,
|
|
nsNetmask InetAddress,
|
|
nsGatewayType InetAddressType,
|
|
nsGateway InetAddress,
|
|
nsHostname OCTET STRING,
|
|
nsDescription OCTET STRING,
|
|
nsVersion OCTET STRING,
|
|
nsUuid OCTET STRING,
|
|
nsInstanceState OCTET STRING,
|
|
nsVirtualFunctions OCTET STRING,
|
|
nsSslVirtualFunctions OCTET STRING,
|
|
nsVmState OCTET STRING,
|
|
nsNumberOfCPU Integer32,
|
|
nsVmMemoryTotal OCTET STRING,
|
|
nsUptime OCTET STRING,
|
|
nsNumberOfSSLCores Integer32,
|
|
nsCpuCoreMgmt OCTET STRING,
|
|
nsCpuCorePE OCTET STRING,
|
|
nsVmDescription OCTET STRING,
|
|
nsThroughput OCTET STRING,
|
|
nsNumberOfCores Integer32,
|
|
nsNsCPUUsage OCTET STRING,
|
|
nsNsMemoryUsage OCTET STRING,
|
|
nsNsTx OCTET STRING,
|
|
nsNsRx OCTET STRING,
|
|
nsHttpReq OCTET STRING,
|
|
nsUpsince OCTET STRING,
|
|
nsLicense OCTET STRING,
|
|
nsHaMasterState OCTET STRING,
|
|
nsHaIPAddressType InetAddressType,
|
|
nsHaIPAddress InetAddress,
|
|
nsNodeState OCTET STRING,
|
|
nsHaSync OCTET STRING,
|
|
nsPps OCTET STRING,
|
|
nsNumberOfSslCoresUp Integer32,
|
|
nsIfOby1 OCTET STRING,
|
|
nsIf0by2 OCTET STRING,
|
|
nsNsVLANId Integer32,
|
|
nsNsVLANTagged OCTET STRING,
|
|
nsVlanType Integer32
|
|
}
|
|
|
|
nsIpAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of nsIpAddress"
|
|
::= { netscalerEntry 1 }
|
|
nsIpAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Address for this managed device"
|
|
::= { netscalerEntry 2 }
|
|
|
|
nsHostIPAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of nsHostIPAddress"
|
|
::= { netscalerEntry 3 }
|
|
nsHostIPAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Host IPAddress where VM is provisioned"
|
|
::= { netscalerEntry 4 }
|
|
|
|
nsProfileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device Profile Name that is attached with this managed device"
|
|
::= { netscalerEntry 5 }
|
|
|
|
nsName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of managed device"
|
|
::= { netscalerEntry 6 }
|
|
|
|
nsNetmaskType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of nsNetmask"
|
|
::= { netscalerEntry 7 }
|
|
nsNetmask OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Netmask of managed device"
|
|
::= { netscalerEntry 8 }
|
|
|
|
nsGatewayType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of nsGateway"
|
|
::= { netscalerEntry 9 }
|
|
nsGateway OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default Gateway of managed device"
|
|
::= { netscalerEntry 10 }
|
|
|
|
nsHostname OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Assign hostname to managed device, if this is not provided, name will be set as host name "
|
|
::= { netscalerEntry 11 }
|
|
|
|
nsDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of managed device"
|
|
::= { netscalerEntry 12 }
|
|
|
|
nsVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device Version"
|
|
::= { netscalerEntry 13 }
|
|
|
|
nsUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UUID of VM Instance"
|
|
::= { netscalerEntry 14 }
|
|
|
|
nsInstanceState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of device, UP only if device accessible"
|
|
::= { netscalerEntry 15 }
|
|
|
|
nsVirtualFunctions OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Virtual Functions assigned to VM Instance"
|
|
::= { netscalerEntry 16 }
|
|
|
|
nsSslVirtualFunctions OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SSL Virtual Functions assigned to VM Instance"
|
|
::= { netscalerEntry 17 }
|
|
|
|
nsVmState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of Virtual Machine (Running | Halted)"
|
|
::= { netscalerEntry 18 }
|
|
|
|
nsNumberOfCPU OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of CPU that is assigned to VM Instance"
|
|
::= { netscalerEntry 19 }
|
|
|
|
nsVmMemoryTotal OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total Memory of VM Instance in MB"
|
|
::= { netscalerEntry 21 }
|
|
|
|
nsUptime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uptime of device"
|
|
::= { netscalerEntry 26 }
|
|
|
|
nsNumberOfSSLCores OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Assign number of ssl virtual functions to VM Instance"
|
|
::= { netscalerEntry 27 }
|
|
|
|
nsCpuCoreMgmt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management CPU cores assigned to VM Instance"
|
|
::= { netscalerEntry 28 }
|
|
|
|
nsCpuCorePE OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Packet Engine cores assigned to VM Instance"
|
|
::= { netscalerEntry 29 }
|
|
|
|
nsVmDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description"
|
|
::= { netscalerEntry 30 }
|
|
|
|
nsThroughput OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Assign throughput in Mbps to VM Instance"
|
|
::= { netscalerEntry 31 }
|
|
|
|
nsNumberOfCores OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of cores that are assigned to VM Instance"
|
|
::= { netscalerEntry 32 }
|
|
|
|
nsNsCPUUsage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU Usage (%) of Citrix ADC Instance"
|
|
::= { netscalerEntry 33 }
|
|
|
|
nsNsMemoryUsage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Memory Usage (%)"
|
|
::= { netscalerEntry 35 }
|
|
|
|
nsNsTx OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Out Throughput of Citrix ADC Instance in Mbps"
|
|
::= { netscalerEntry 36 }
|
|
|
|
nsNsRx OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In Throughput of Citrix ADC Instance in Mbps"
|
|
::= { netscalerEntry 37 }
|
|
|
|
nsHttpReq OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HTTP Requests/second"
|
|
::= { netscalerEntry 38 }
|
|
|
|
nsUpsince OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Upsince of managed device"
|
|
::= { netscalerEntry 39 }
|
|
|
|
nsLicense OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Feature License for Citrix ADC Instance, needs to be set while provisioning (standard, enterprise, platinum)"
|
|
::= { netscalerEntry 40 }
|
|
|
|
nsHaMasterState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Master State (Primary/Secondary)"
|
|
::= { netscalerEntry 41 }
|
|
|
|
nsHaIPAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of nsHaIPAddress"
|
|
::= { netscalerEntry 42 }
|
|
nsHaIPAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Peer IP Address"
|
|
::= { netscalerEntry 43 }
|
|
|
|
nsNodeState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Node State of Citrix ADC Instance"
|
|
::= { netscalerEntry 44 }
|
|
|
|
nsHaSync OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HA Synchronization State"
|
|
::= { netscalerEntry 45 }
|
|
|
|
nsPps OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Assign packets per seconds to Citrix ADC Instance"
|
|
::= { netscalerEntry 46 }
|
|
|
|
nsNumberOfSslCoresUp OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of SSL Cores Up"
|
|
::= { netscalerEntry 47 }
|
|
|
|
nsIfOby1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network 0/1 on VM Instance"
|
|
::= { netscalerEntry 48 }
|
|
|
|
nsIf0by2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network 0/2 on VM Instance"
|
|
::= { netscalerEntry 49 }
|
|
|
|
nsNsVLANId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN Id"
|
|
::= { netscalerEntry 50 }
|
|
|
|
nsNsVLANTagged OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSVLAN Tagged"
|
|
::= { netscalerEntry 51 }
|
|
|
|
nsVlanType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN Type, Citrix ADC or L2 VLAN"
|
|
::= { netscalerEntry 52 }
|
|
|
|
cloudBridgeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CloudBridgeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cloudBridgetable"
|
|
::= { deviceGroup 3 }
|
|
|
|
cloudBridgeEntry OBJECT-TYPE
|
|
SYNTAX CloudBridgeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
INDEX { cbIpAddressType, cbIpAddress, cbHostIPAddressType, cbHostIPAddress }
|
|
::= { cloudBridgeTable 1}
|
|
|
|
CloudBridgeEntry ::= SEQUENCE {
|
|
cbIpAddressType InetAddressType,
|
|
cbIpAddress InetAddress,
|
|
cbHostIPAddressType InetAddressType,
|
|
cbHostIPAddress InetAddress,
|
|
cbProfileName OCTET STRING,
|
|
cbName OCTET STRING,
|
|
cbNetmaskType InetAddressType,
|
|
cbNetmask InetAddress,
|
|
cbGatewayType InetAddressType,
|
|
cbGateway InetAddress,
|
|
cbHostname OCTET STRING,
|
|
cbDescription OCTET STRING,
|
|
cbVersion OCTET STRING,
|
|
cbInstanceState OCTET STRING,
|
|
cbUuid OCTET STRING,
|
|
cbVirtualFunctions OCTET STRING,
|
|
cbVmState OCTET STRING,
|
|
cbNumberOfCPU Integer32,
|
|
cbVmCPUUsage OCTET STRING,
|
|
cbVmMemoryTotal OCTET STRING,
|
|
cbVmMemoryFree OCTET STRING,
|
|
cbVmMemoryUsage OCTET STRING,
|
|
cbUptime OCTET STRING,
|
|
cbDiskAllocation OCTET STRING,
|
|
cbAPAIPADDRESSType InetAddressType,
|
|
cbAPAIPADDRESS InetAddress,
|
|
cbAPANetMaskType InetAddressType,
|
|
cbAPANetMask InetAddress,
|
|
cbAPAGatewayType InetAddressType,
|
|
cbAPAGateway InetAddress,
|
|
cbPluginIPADDRESSType InetAddressType,
|
|
cbPluginIPADDRESS InetAddress,
|
|
cbMgmtIPAddressType InetAddressType,
|
|
cbMgmtIPAddress InetAddress
|
|
}
|
|
|
|
cbIpAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbIpAddress"
|
|
::= { cloudBridgeEntry 1 }
|
|
cbIpAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Address for this managed device"
|
|
::= { cloudBridgeEntry 2 }
|
|
|
|
cbHostIPAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbHostIPAddress"
|
|
::= { cloudBridgeEntry 3 }
|
|
cbHostIPAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Host IPAddress where VM is provisioned"
|
|
::= { cloudBridgeEntry 4 }
|
|
|
|
cbProfileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device Profile Name that is attached with this managed device"
|
|
::= { cloudBridgeEntry 5 }
|
|
|
|
cbName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of managed device"
|
|
::= { cloudBridgeEntry 6 }
|
|
|
|
cbNetmaskType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbNetmask"
|
|
::= { cloudBridgeEntry 7 }
|
|
cbNetmask OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Netmask of managed device"
|
|
::= { cloudBridgeEntry 8 }
|
|
|
|
cbGatewayType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbGateway"
|
|
::= { cloudBridgeEntry 9 }
|
|
cbGateway OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default Gateway of managed device"
|
|
::= { cloudBridgeEntry 10 }
|
|
|
|
cbHostname OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Assign hostname to managed device, if this is not provided, name will be set as host name "
|
|
::= { cloudBridgeEntry 11 }
|
|
|
|
cbDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of managed device"
|
|
::= { cloudBridgeEntry 12 }
|
|
|
|
cbVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device Version"
|
|
::= { cloudBridgeEntry 13 }
|
|
|
|
cbInstanceState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of device, UP only if device accessible"
|
|
::= { cloudBridgeEntry 14 }
|
|
|
|
cbUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UUID of VM Instance"
|
|
::= { cloudBridgeEntry 15 }
|
|
|
|
cbVirtualFunctions OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Virtual Functions assigned to VM Instance"
|
|
::= { cloudBridgeEntry 16 }
|
|
|
|
cbVmState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of Virtual Machine (Running | Halted)"
|
|
::= { cloudBridgeEntry 17 }
|
|
|
|
cbNumberOfCPU OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of CPU that is assigned to VM Instance"
|
|
::= { cloudBridgeEntry 18 }
|
|
|
|
cbVmCPUUsage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU Usage (%) of VM Instance"
|
|
::= { cloudBridgeEntry 19 }
|
|
|
|
cbVmMemoryTotal OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total Memory of VM Instance in MB"
|
|
::= { cloudBridgeEntry 20 }
|
|
|
|
cbVmMemoryFree OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Free Memory (MB) available in VM Instance"
|
|
::= { cloudBridgeEntry 21 }
|
|
|
|
cbVmMemoryUsage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Memory Usage (%) of VM Instance"
|
|
::= { cloudBridgeEntry 22 }
|
|
|
|
cbUptime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uptime of device"
|
|
::= { cloudBridgeEntry 25 }
|
|
|
|
cbDiskAllocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Disk allocation for VM Instance"
|
|
::= { cloudBridgeEntry 30 }
|
|
|
|
cbAPAIPADDRESSType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbAPAIPADDRESS"
|
|
::= { cloudBridgeEntry 47 }
|
|
cbAPAIPADDRESS OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"aPA IP Address"
|
|
::= { cloudBridgeEntry 48 }
|
|
|
|
cbAPANetMaskType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbAPANetMask"
|
|
::= { cloudBridgeEntry 49 }
|
|
cbAPANetMask OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"aPA Netmask"
|
|
::= { cloudBridgeEntry 50 }
|
|
|
|
cbAPAGatewayType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbAPAGateway"
|
|
::= { cloudBridgeEntry 51 }
|
|
cbAPAGateway OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"aPA Gateway"
|
|
::= { cloudBridgeEntry 52 }
|
|
|
|
cbPluginIPADDRESSType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbPluginIPADDRESS"
|
|
::= { cloudBridgeEntry 53 }
|
|
cbPluginIPADDRESS OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Plugin IP Address"
|
|
::= { cloudBridgeEntry 54 }
|
|
|
|
cbMgmtIPAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbMgmtIPAddress"
|
|
::= { cloudBridgeEntry 57 }
|
|
cbMgmtIPAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management IP Address for this Managed Device"
|
|
::= { cloudBridgeEntry 58 }
|
|
|
|
cloudBridgeAcceleratorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CloudBridgeAcceleratorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cloudBridgeAcceleratortable"
|
|
::= { deviceGroup 4 }
|
|
|
|
cloudBridgeAcceleratorEntry OBJECT-TYPE
|
|
SYNTAX CloudBridgeAcceleratorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"..."
|
|
INDEX { cbAcceleratorIpAddressType, cbAcceleratorIpAddress, cbAcceleratorHostIPAddressType, cbAcceleratorHostIPAddress }
|
|
::= { cloudBridgeAcceleratorTable 1}
|
|
|
|
CloudBridgeAcceleratorEntry ::= SEQUENCE {
|
|
cbAcceleratorIpAddressType InetAddressType,
|
|
cbAcceleratorIpAddress InetAddress,
|
|
cbAcceleratorHostIPAddressType InetAddressType,
|
|
cbAcceleratorHostIPAddress InetAddress,
|
|
cbAcceleratorProfileName OCTET STRING,
|
|
cbAcceleratorName OCTET STRING,
|
|
cbAcceleratorNetmaskType InetAddressType,
|
|
cbAcceleratorNetmask InetAddress,
|
|
cbAcceleratorGatewayType InetAddressType,
|
|
cbAcceleratorGateway InetAddress,
|
|
cbAcceleratorHostname OCTET STRING,
|
|
cbAcceleratorDescription OCTET STRING,
|
|
cbAcceleratorVersion OCTET STRING,
|
|
cbAcceleratorInstanceState OCTET STRING,
|
|
cbAcceleratorUuid OCTET STRING,
|
|
cbAcceleratorVmState OCTET STRING,
|
|
cbAcceleratorNumberOfCPU Integer32,
|
|
cbAcceleratorVmCPUUsage OCTET STRING,
|
|
cbAcceleratorVmMemoryTotal OCTET STRING,
|
|
cbAcceleratorVmMemoryFree OCTET STRING,
|
|
cbAcceleratorVmMemoryUsage OCTET STRING,
|
|
cbAcceleratorUptime OCTET STRING,
|
|
cbAcceleratorIpList OCTET STRING,
|
|
cbAcceleratorMgmtIPAddressType InetAddressType,
|
|
cbAcceleratorMgmtIPAddress InetAddress
|
|
}
|
|
|
|
cbAcceleratorIpAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbAcceleratorIpAddress"
|
|
::= { cloudBridgeAcceleratorEntry 1 }
|
|
cbAcceleratorIpAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Address for this managed device"
|
|
::= { cloudBridgeAcceleratorEntry 2 }
|
|
|
|
cbAcceleratorHostIPAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbAcceleratorHostIPAddress"
|
|
::= { cloudBridgeAcceleratorEntry 3 }
|
|
cbAcceleratorHostIPAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Host IPAddress where VM is provisioned"
|
|
::= { cloudBridgeAcceleratorEntry 4 }
|
|
|
|
cbAcceleratorProfileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device Profile Name that is attached with this managed device"
|
|
::= { cloudBridgeAcceleratorEntry 5 }
|
|
|
|
cbAcceleratorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of managed device"
|
|
::= { cloudBridgeAcceleratorEntry 6 }
|
|
|
|
cbAcceleratorNetmaskType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbAcceleratorNetmask"
|
|
::= { cloudBridgeAcceleratorEntry 7 }
|
|
cbAcceleratorNetmask OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Netmask of managed device"
|
|
::= { cloudBridgeAcceleratorEntry 8 }
|
|
|
|
cbAcceleratorGatewayType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbAcceleratorGateway"
|
|
::= { cloudBridgeAcceleratorEntry 9 }
|
|
cbAcceleratorGateway OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default Gateway of managed device"
|
|
::= { cloudBridgeAcceleratorEntry 10 }
|
|
|
|
cbAcceleratorHostname OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Assign hostname to managed device, if this is not provided, name will be set as host name "
|
|
::= { cloudBridgeAcceleratorEntry 11 }
|
|
|
|
cbAcceleratorDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of managed device"
|
|
::= { cloudBridgeAcceleratorEntry 12 }
|
|
|
|
cbAcceleratorVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device Version"
|
|
::= { cloudBridgeAcceleratorEntry 13 }
|
|
|
|
cbAcceleratorInstanceState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of device, UP only if device accessible"
|
|
::= { cloudBridgeAcceleratorEntry 14 }
|
|
|
|
cbAcceleratorUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UUID of VM Instance"
|
|
::= { cloudBridgeAcceleratorEntry 15 }
|
|
|
|
cbAcceleratorVmState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of Virtual Machine (Running | Halted)"
|
|
::= { cloudBridgeAcceleratorEntry 16 }
|
|
|
|
cbAcceleratorNumberOfCPU OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of CPU that is assigned to VM Instance"
|
|
::= { cloudBridgeAcceleratorEntry 17 }
|
|
|
|
cbAcceleratorVmCPUUsage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU Usage (%) of VM Instance"
|
|
::= { cloudBridgeAcceleratorEntry 18 }
|
|
|
|
cbAcceleratorVmMemoryTotal OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total Memory of VM Instance in MB"
|
|
::= { cloudBridgeAcceleratorEntry 19 }
|
|
|
|
cbAcceleratorVmMemoryFree OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Free Memory (MB) available in VM Instance"
|
|
::= { cloudBridgeAcceleratorEntry 20 }
|
|
|
|
cbAcceleratorVmMemoryUsage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Memory Usage (%) of VM Instance"
|
|
::= { cloudBridgeAcceleratorEntry 21 }
|
|
|
|
cbAcceleratorUptime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uptime of device"
|
|
::= { cloudBridgeAcceleratorEntry 24 }
|
|
|
|
cbAcceleratorIpList OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the list of Citrix SD-WAN IPs for which this device will act as a Citrix SD-WAN Accelerator."
|
|
::= { cloudBridgeAcceleratorEntry 31 }
|
|
|
|
cbAcceleratorMgmtIPAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of cbAcceleratorMgmtIPAddress"
|
|
::= { cloudBridgeAcceleratorEntry 38 }
|
|
cbAcceleratorMgmtIPAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management IP Address for this Managed Device"
|
|
::= { cloudBridgeAcceleratorEntry 39 }
|
|
|
|
|
|
eventVarBindOids OBJECT IDENTIFIER
|
|
::= { masEventGroup 1 }
|
|
|
|
source OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the device generating the event"
|
|
::= { eventVarBindOids 1 }
|
|
|
|
entityName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the entity associated with this alarm"
|
|
::= { eventVarBindOids 2 }
|
|
|
|
entityType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of entity associated with this alarm"
|
|
::= { eventVarBindOids 3 }
|
|
|
|
eventMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Message associated with this alarm"
|
|
::= { eventVarBindOids 4 }
|
|
|
|
thresholdValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High threshold value configured for this alarm"
|
|
::= { eventVarBindOids 5 }
|
|
|
|
currentValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current value of the entity when high or normal threshold trap is sent"
|
|
::= { eventVarBindOids 6 }
|
|
|
|
severity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associated with this alarm"
|
|
::= { eventVarBindOids 7 }
|
|
|
|
|
|
mpsEvents OBJECT IDENTIFIER
|
|
::= { masEventGroup 2 }
|
|
|
|
cpuUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, currentValue, thresholdValue, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU utilization has exceeded the high threshold value"
|
|
::= { mpsEvents 1 }
|
|
|
|
cpuUsageNormal NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, currentValue, thresholdValue, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU utilization has returned to normal"
|
|
::= { mpsEvents 2 }
|
|
|
|
memoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, currentValue, thresholdValue, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Memory utilization has exceeded the high threshold value."
|
|
::= { mpsEvents 3 }
|
|
|
|
memoryUsageNormal NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, currentValue, thresholdValue, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Memory utilization has returned to normal"
|
|
::= { mpsEvents 4 }
|
|
|
|
diskUtilizationHigh NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, currentValue, thresholdValue, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when the Disk utilization goes high. 'entityName' and 'eventMessage' will show specific failure information"
|
|
::= { mpsEvents 35 }
|
|
|
|
diskUtilizationNormal NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, currentValue, thresholdValue, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when the Disk utilization becomes normal. 'entityName' and 'eventMessage' will show specific failure information"
|
|
::= { mpsEvents 36 }
|
|
|
|
subSystemDown NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A subsystem has gone DOWN; entityName shows details"
|
|
::= { mpsEvents 43 }
|
|
|
|
subSystemUp NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A subsystem has returned to the UP state; entityName shows details"
|
|
::= { mpsEvents 44 }
|
|
|
|
subSystemFailed NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A subsystem has failed; entityName shows details"
|
|
::= { mpsEvents 45 }
|
|
|
|
mpsDown NOTIFICATION-TYPE
|
|
OBJECTS {source, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All subsystems are DOWN"
|
|
::= { mpsEvents 46 }
|
|
|
|
mpsUp NOTIFICATION-TYPE
|
|
OBJECTS {source, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All subsystems are UP"
|
|
::= { mpsEvents 47 }
|
|
|
|
passwordRecoveryFailed NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Password recovery has failed"
|
|
::= { mpsEvents 48 }
|
|
|
|
passwordRecoverySuccess NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Password has been recovered successfully"
|
|
::= { mpsEvents 49 }
|
|
|
|
deviceStateChanged NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Instance state of a managed device has changed"
|
|
::= { mpsEvents 54 }
|
|
|
|
backupFailed NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when the backup operation fails"
|
|
::= { mpsEvents 58 }
|
|
|
|
loginFailure NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when User Authentication fails. 'entityName' and 'eventMessage' will show specific failure information"
|
|
::= { mpsEvents 71 }
|
|
|
|
inventoryFailed NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"XenServer inventory collection has failed"
|
|
::= { mpsEvents 72 }
|
|
|
|
trapConfigFailure NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when failure occurs in adding snmp trap destination"
|
|
::= { mpsEvents 78 }
|
|
|
|
pooledLicenseGrace NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OnGrace; entityName and eventMessage show License is on grace"
|
|
::= { mpsEvents 80 }
|
|
|
|
pooledLicenseGraceNormal NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"License in not under Grace"
|
|
::= { mpsEvents 81 }
|
|
|
|
licensePoolThresholdWarning NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"licensePoolThresholdWarning; LicensePool is crossed Threshold value"
|
|
::= { mpsEvents 84 }
|
|
|
|
licensePoolThresholdNormal NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LicensePool is below Threshold value"
|
|
::= { mpsEvents 85 }
|
|
|
|
vipLicenseLimitWarning NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VIPs are more than License Limit"
|
|
::= { mpsEvents 86 }
|
|
|
|
vipLicenseLimitNormal NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VIPs are below than License Limit"
|
|
::= { mpsEvents 87 }
|
|
|
|
remoteBackupFailed NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when Remote Backup fails."
|
|
::= { mpsEvents 88 }
|
|
|
|
remoteBackupResumed NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when Remote Backup failure is rectified and its running again."
|
|
::= { mpsEvents 89 }
|
|
|
|
perfCounterThresholdHigh NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"perfCounterThresholdHigh; Performance counter value has crossed the Threshold value"
|
|
::= { mpsEvents 90 }
|
|
|
|
perfCounterThresholdNormal NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"perfCounterThresholdNormal; Performance counter value is below the Clear value"
|
|
::= { mpsEvents 91 }
|
|
|
|
devicebackupFailed NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when the device backup operation fails"
|
|
::= { mpsEvents 92 }
|
|
|
|
remoteDeviceBackupFailed NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when Remote Device Backup fails."
|
|
::= { mpsEvents 93 }
|
|
|
|
dataStorageExceeded NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"dataStorageExceeded;Database storage exceeds the limit specified in license"
|
|
::= { mpsEvents 94 }
|
|
|
|
dataStorageNormal NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"dataStorageNormal;Database storage is within the limit allowed by license."
|
|
::= { mpsEvents 95 }
|
|
|
|
sslCertThresholdBreached NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sslCertThresholdBreached;Certificate expiry"
|
|
::= { mpsEvents 96 }
|
|
|
|
sslCertThresholdNormal NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sslCertThresholdNormal"
|
|
::= { mpsEvents 97 }
|
|
|
|
haFailover NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HA Failover happened."
|
|
::= { mpsEvents 98 }
|
|
|
|
haNoHeartBeats NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No Heartbeats from peer."
|
|
::= { mpsEvents 99 }
|
|
|
|
haDatabaseOutOfSync NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HA nodes database out of sync"
|
|
::= { mpsEvents 100 }
|
|
|
|
inventoryUp NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inventory has returned to normal condition"
|
|
::= { mpsEvents 101 }
|
|
|
|
deviceBooted NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A managed device has failed to start"
|
|
::= { mpsEvents 104 }
|
|
|
|
deviceRebooted NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A managed device has failed to restart"
|
|
::= { mpsEvents 105 }
|
|
|
|
autoScaleGroupAdded NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup Added"
|
|
::= { mpsEvents 106 }
|
|
|
|
autoScaleGroupModified NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup Modified"
|
|
::= { mpsEvents 107 }
|
|
|
|
autoScaleGroupDeleted NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup Deleted"
|
|
::= { mpsEvents 108 }
|
|
|
|
clusterProvisionStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Cluster Provision Status"
|
|
::= { mpsEvents 109 }
|
|
|
|
nodeProvisionStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Node Provision Status"
|
|
::= { mpsEvents 110 }
|
|
|
|
coolDownPeriodStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Cool Down Period Status"
|
|
::= { mpsEvents 111 }
|
|
|
|
clusterDeprovisionStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Cluster Deprovision Status"
|
|
::= { mpsEvents 112 }
|
|
|
|
nodeDeprovisionStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Node Deprovision Status"
|
|
::= { mpsEvents 113 }
|
|
|
|
drainConnPeriodStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Drain Connection Period Status"
|
|
::= { mpsEvents 114 }
|
|
|
|
deployAppStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Deploy application status"
|
|
::= { mpsEvents 115 }
|
|
|
|
modifyAppStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Modify application status"
|
|
::= { mpsEvents 116 }
|
|
|
|
deleteAppStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Delete application status"
|
|
::= { mpsEvents 117 }
|
|
|
|
ipLimitReached NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: IP Limit Reached"
|
|
::= { mpsEvents 118 }
|
|
|
|
scaleOutStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Scale Out Status"
|
|
::= { mpsEvents 119 }
|
|
|
|
scaleInStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Scale In Status"
|
|
::= { mpsEvents 120 }
|
|
|
|
addIPSetStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: IPSet creation status"
|
|
::= { mpsEvents 121 }
|
|
|
|
deleteIPSetStatus NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: IPSet deletion status"
|
|
::= { mpsEvents 122 }
|
|
|
|
addZone NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Add Zone status"
|
|
::= { mpsEvents 123 }
|
|
|
|
deleteZone NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Delete Zone status"
|
|
::= { mpsEvents 124 }
|
|
|
|
addRecord NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Add record status"
|
|
::= { mpsEvents 125 }
|
|
|
|
deleteRecord NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Add record status"
|
|
::= { mpsEvents 126 }
|
|
|
|
addRRData NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Add rrdata status"
|
|
::= { mpsEvents 127 }
|
|
|
|
deleteRRData NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: delete rrdata status"
|
|
::= { mpsEvents 128 }
|
|
|
|
instancePolicyReconfigurationFailed NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reconfiguration of policies failed on an instance"
|
|
::= { mpsEvents 131 }
|
|
|
|
instancePolicyReconfigurationSucceeded NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reconfiguration of policies succeeded on an instance"
|
|
::= { mpsEvents 132 }
|
|
|
|
autoscalegroupUpgrade NOTIFICATION-TYPE
|
|
OBJECTS {source, entityName, eventMessage, severity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AutoScaleGroup: Upgrade AutoScaleGroup"
|
|
::= { mpsEvents 133 }
|
|
|
|
|
|
END -- end of module MIB
|