mibs/MIBS/comware/HH3C-BFD-STD-MIB
2023-12-05 12:25:34 +01:00

932 lines
33 KiB
Plaintext

-- ============================================================================
-- Copyright (c) 2004-2021 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: The MIB is extracted from draft-ietf-bfd-base-04.txt.
-- This file defines a portion of the Management Information Base (MIB) for use
-- with network management protocols in the Internet community. It describes
-- managed objects to configure or monitor Bi-Directional Forwarding Detection
-- on devices supporting this feature.
-- Reference:
-- Version: V1.5
-- History:
-- V1.0 2006-05-15 created by huanglina and xuqigang
-- V1.1 2014-01-20 modified by wangxingying
-- V1.2 2014-12-23 modified by wangxingying
-- V1.3 2016-03-12 modified by guobin
-- V1.4 2020-08-13 Update hh3cBfdGlobalObjects by xukele
-- V1.5 2021-03-18 Add hh3cBfdTrapBindObjects, and update hh3cBfdSessStateDown, hh3cBfdSessStateUp by xukele
-- ============================================================================
HH3C-BFD-STD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Unsigned32, Counter32, Counter64,
NOTIFICATION-TYPE
FROM SNMPv2-SMI -- [RFC2578]
TEXTUAL-CONVENTION, TruthValue,
TimeStamp,DisplayString
FROM SNMPv2-TC
InterfaceIndex
FROM IF-MIB
InetAddress, InetAddressType, InetPortNumber
FROM INET-ADDRESS-MIB -- [RFC3291]
hh3cCommon
FROM HH3C-OID-MIB;
hh3cBfdMIB MODULE-IDENTITY
LAST-UPDATED "202103181100Z" -- 18 Mar 2021 11:00:00 Beijing time
ORGANIZATION
"New H3C Tech. Co., Ltd."
CONTACT-INFO
"Platform Team New H3C Tech. Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip:100085
"
DESCRIPTION
"Bidirectional Forwarding Management Information Base."
-- Revision history.
REVISION "202103181100Z" -- 18 Mar 2021 11:00:00 Beijing time
DESCRIPTION
"Add hh3cBfdTrapBindObjects, and modified the objects of hh3cBfdSessStateDown and hh3cBfdSessStateUp."
REVISION "202008131100Z" -- 13 Aug 2020 11:00:00 Beijing time
DESCRIPTION
"Modified the objects of hh3cBfdGlobalObjects."
REVISION "201412131200Z" -- 13 Dec 2014 12:00:00 Beijing time
DESCRIPTION
"Modified the objects of hh3cBfdSessEntry."
REVISION "201401171200Z" -- 17 Jan 2014 12:00:00 Beijing time
DESCRIPTION
"Modified for bfd trap."
REVISION "200605161200Z" -- 08 May 2006 12:00:00 Beijing time
DESCRIPTION
"The first version. "
::= { hh3cCommon 72 }
-- Top level components of this MIB module.
hh3cBfdNotifications OBJECT IDENTIFIER ::= { hh3cBfdMIB 0 }
hh3cBfdObjects OBJECT IDENTIFIER ::= { hh3cBfdMIB 1 }
hh3cBfdConformance OBJECT IDENTIFIER ::= { hh3cBfdMIB 2 }
hh3cBfdGlobalObjects OBJECT IDENTIFIER ::= { hh3cBfdObjects 1 }
hh3cBfdTrapBindObjects OBJECT IDENTIFIER ::= { hh3cBfdMIB 3 }
-- Textual Conventions
BfdSessIndexTC ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"An index used to uniquely identify BFD sessions."
SYNTAX Unsigned32 (1..4294967295)
BfdInterval ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A time interval delay in microseconds, which is used by the BFD."
SYNTAX Unsigned32 (1..4294967295)
BfdDiag ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The diagnostic code is used by the BFD specifying the local
system's reason for the last session state change, and must
be initialized to zero(No Diagnostic).
The 'noDiagnostic' means the session keeps state up.
The 'controlDetectionTimeExpired' indicates the reason the session
enters state down from state up is that the control detection time
expires.
The 'echoFunctionFailed' indicates the reason the session
enters state down from state up is that Echo Function fails.
The 'neighborSignaledSessionDown' indicates the reason the session
enters state down from state up is that neighbor signals session Down.
The 'forwardingPlaneReset' indicates the reason the session
enters state down from state up is that the Forwarding Plane resets.
The 'pathDown' indicates the reason the session
enters state down from state up is that the path state is down.
The 'concatenatedPathDown' indicates the reason the session
enters state down from state up is that the concatenated path state
is down.
The 'administrativelyDown' indicates the reason the session
enters state down from state up is that the session is kept
administratively down by entering the AdminDown state.
The 'reverseConcatenatedPathDown' indicates the reason the session
enters state down from state up is that reverse concatenated path
state is down."
SYNTAX INTEGER { noDiagnostic(1),
controlDetectionTimeExpired(2),
echoFunctionFailed(3),
neighborSignaledSessionDown(4),
forwardingPlaneReset(5),
pathDown(6),
concatenatedPathDown(7),
administrativelyDown(8),
reverseConcatenatedPathDown(9)
}
Hh3cBfdBindVpnInstanceName ::= TEXTUAL-CONVENTION
DISPLAY-HINT "31a"
STATUS current
DESCRIPTION
"An identifier that is assigned to each MPLS/BGP VPN and
is used to uniquely identify it. This is assigned by the
system operator or NMS and SHOULD be unique throughout
the MPLS domain. If this is the case, then this identifier
can then be used at any LSR within a specific MPLS domain
to identify this MPLS/BGP VPN. It may also be possible to
preserve the uniqueness of this identifier across MPLS
domain boundaries, in which case this identifier can then
be used to uniquely identify MPLS/BGP VPNs on a more global
basis. This object MAY be set to the VPN ID as defined in
RFC 2685."
REFERENCE
"RFC 2685 Fox B., et al, 'Virtual Private
Networks Identifier', September 1999."
SYNTAX OCTET STRING (SIZE (0..31))
Hh3cBfdSessionName ::= TEXTUAL-CONVENTION
DISPLAY-HINT "64a"
STATUS current
DESCRIPTION
"A name used to uniquely identify BFD sessions."
SYNTAX OCTET STRING(SIZE (0..64))
-- BFD General Variables
-- These variables apply globally to the Router's BFD Process.
hh3cBfdVersionNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It indicates the BFD session's current version number."
REFERENCE
"BFD Version 1 (draft-ietf-bfd-base-04.txt)"
DEFVAL { 1 }
::= { hh3cBfdGlobalObjects 1 }
hh3cBfdSysInitMode OBJECT-TYPE
SYNTAX INTEGER { active(1), passive(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A system may take either an active role or a passive role in
session initialization. A system taking the active role must
send BFD control packets for a particular session, regardless
of whether it has received any BFD packets for that session.
A system taking the passive role must not begin sending BFD
packets for a particular session until it has received a BFD
packet for that session, and thus has learned the remote system's
discriminator value."
DEFVAL { active }
::= { hh3cBfdGlobalObjects 2 }
hh3cBfdSessNotificationsEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the emission of hh3cBfdSessStateUp
hh3cBfdSessStateDown and hh3cBfdSessReachLimit notifications
if this variable is set to true(1); otherwise these notifications
are not emitted."
DEFVAL { false }
::= { hh3cBfdGlobalObjects 3 }
hh3cBfdSessNumberLimit OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable is the active session limit of this device."
::= { hh3cBfdGlobalObjects 4 }
hh3cBfdSessionsActive OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable is the active session count of this device."
::= { hh3cBfdGlobalObjects 5 }
-- BFD Interface Table
-- The BFD Interface Table defines BFD interface specific information.
hh3cBfdIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cBfdIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This Table describes the BFD interface specific information."
::= { hh3cBfdObjects 2 }
hh3cBfdIfEntry OBJECT-TYPE
SYNTAX Hh3cBfdIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This Entry describes the BFD interface specific information."
INDEX { hh3cBfdIfIndex }
::= { hh3cBfdIfTable 1 }
Hh3cBfdIfEntry ::= SEQUENCE {
hh3cBfdIfIndex InterfaceIndex,
hh3cBfdIfDesiredMinTxInterval BfdInterval,
hh3cBfdIfDesiredMinRxInterval BfdInterval,
hh3cBfdIfDetectMult Unsigned32,
hh3cBfdIfAuthType INTEGER
}
hh3cBfdIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This variable contains an index that represents a
unique BFD interface on this device."
::= { hh3cBfdIfEntry 1 }
hh3cBfdIfDesiredMinTxInterval OBJECT-TYPE
SYNTAX BfdInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the minimum interval, in
microseconds, that the interface would like to use when
transmitting BFD Control packets."
::= { hh3cBfdIfEntry 2 }
hh3cBfdIfDesiredMinRxInterval OBJECT-TYPE
SYNTAX BfdInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the minimum interval, in,
microseconds, between received BFD Control packets the
local system is capable of supporting."
::= { hh3cBfdIfEntry 3 }
hh3cBfdIfDetectMult OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired detect time multiplier for BFD control packets.
The negotiated control packet transmission interval, multiplied
by this variable, will be the detection time for this session
(as seen by the remote system.) The variable must be a
nonzero integer."
::= { hh3cBfdIfEntry 4 }
hh3cBfdIfAuthType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
simple(2),
md5(3),
mmd5(4),
sha1(5),
msha1(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Authentication Type used for this interface. This
field is valid only when the Authentication Present bit is set.
The 'none' indicates the session doesn't support
authentication.
The 'simple' indicates the session supports simple
password authentication.
The 'md5' indicates the session supports Keyed MD5
authentication.
The 'mmd5' indicates the session supports
Meticulous Keyed MD5 authentication.
The 'sha1' indicates the session supports Keyed SHA1
authentication.
The 'msha1' indicates the session supports
Meticulous Keyed SHA1 authentication."
DEFVAL { none }
::= { hh3cBfdIfEntry 5 }
-- BFD Session Table
-- The BFD Session Table defines BFD session specific information.
hh3cBfdSessTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cBfdSessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes the BFD sessions."
REFERENCE
"BFD Version 1 (draft-ietf-bfd-base-04.txt)"
::= { hh3cBfdObjects 3 }
hh3cBfdSessEntry OBJECT-TYPE
SYNTAX Hh3cBfdSessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This Entry describes the BFD sessions."
INDEX { hh3cBfdSessIndex }
::= { hh3cBfdSessTable 1 }
Hh3cBfdSessEntry ::= SEQUENCE {
hh3cBfdSessIndex BfdSessIndexTC,
hh3cBfdSessIfIndex InterfaceIndex,
hh3cBfdSessAppSupportId BITS,
hh3cBfdSessLocalDiscr Unsigned32,
hh3cBfdSessRemoteDiscr Unsigned32,
hh3cBfdSessDstPort InetPortNumber,
hh3cBfdSessOperMode INTEGER,
hh3cBfdSessAddrType InetAddressType,
hh3cBfdSessLocalAddr InetAddress,
hh3cBfdSessRemoteAddr InetAddress,
hh3cBfdSessLocalDiag BfdDiag,
hh3cBfdSessState INTEGER,
hh3cBfdSessControlPlanIndepFlag TruthValue,
hh3cBfdSessAuthFlag TruthValue,
hh3cBfdSessDemandModeFlag TruthValue
}
hh3cBfdSessIndex OBJECT-TYPE
SYNTAX BfdSessIndexTC
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This variable contains an index which represents a
unique BFD session on this device."
::= { hh3cBfdSessEntry 1 }
hh3cBfdSessIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable contains an interface's index under which the BFD
session runs."
::= { hh3cBfdSessEntry 2 }
hh3cBfdSessAppSupportId OBJECT-TYPE
SYNTAX BITS {none(0), ospf(1), isis(2), bgp(3), mpls(4)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable contains an ID used to indicate
a local application which owns or maintains this
BFD session. Note, a BFD session can support several route
protocols. This is a bit-map of possible conditions.
The corresponding bit positions are:
|0 |none |
|1 |ospf |
|2 |isis |
|3 |bgp |
|4 |mpls |
"
::= { hh3cBfdSessEntry 3 }
hh3cBfdSessLocalDiscr OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable defines the local discriminator for this BFD
session, used to uniquely identify it."
::= { hh3cBfdSessEntry 4 }
hh3cBfdSessRemoteDiscr OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable defines the session discriminator chosen
by the remote system for this BFD session."
::= { hh3cBfdSessEntry 5 }
hh3cBfdSessDstPort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UDP Port for BFD. The default value is the
well-known value for this port."
REFERENCE
"BFD Version 1 (draft-ietf-bfd-base-04.txt)"
DEFVAL { 3784 }
::= { hh3cBfdSessEntry 6 }
hh3cBfdSessOperMode OBJECT-TYPE
SYNTAX INTEGER {
asynchModeWOEchoFun(1),
demandModeWOEchoFunction(2),
asyncModeWEchoFun(3),
demandModeWEchoFunction(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable defines current operating mode that BFD
session is running in.
The primary mode which the BFD session runs in is known as
Asynchronous mode. In this mode, the systems periodically
send BFD Control packets to one another, and if a number of
those packets in a row are not received by the other system,
the session is declared to be down.
The second mode is known as Demand mode. In this mode, it is
assumed that each system has an independent way of verifying
that it has connectivity to the other system. Once a BFD
session is established, the systems stop sending BFD Control
packets, except when either system feels the need to verify
connectivity explicitly, in which case a short sequence of BFD
Control packets is sent, and then the protocol quiesces.
An adjunct to both modes is the Echo function. When the Echo
function is active, a stream of BFD Echo packets is transmitted
in such a way as to have the other system loop them back through
its forwarding path. If a number of packets of the echoed data
stream are not received, the session is declared to be down.
The Echo function may be used with either Asynchronous or
Demand modes.
The 'asynchModeWOEchoFun' indicates this BFD session operates in
the Asynchronous mode, and doesn't support the Echo Function.
The 'demandModeWOEchoFunction' indicates this BFD session operates in
the Demand mode, and doesn't support the Echo Function.
The 'asyncModeWEchoFun' indicates this BFD session operates in
the Asynchronous mode, and also supports the Echo Function.
The 'demandModeWEchoFunction' indicates this BFD session operates in
the Demand mode, and also supports the Echo Function."
DEFVAL { asynchModeWOEchoFun }
::= { hh3cBfdSessEntry 7 }
hh3cBfdSessAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines IP address type of the interface
associated with this BFD session.
Only values unknown(0), ipv4(1) or ipv6(2)
have to be supported.
A value of unknown(0) is allowed only when
the outgoing interface is of type point-to-point, or
when the BFD session is not associated with a specific
interface.
If any other unsupported values are attempted in a set
operation, the agent must return an inconsistentValue
error."
::= { hh3cBfdSessEntry 8 }
hh3cBfdSessLocalAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable defines IP address of the local interface
from which the BFD packets is transmitted.
It can also be used to enabled BFD on a specific
interface. The value is set to zero when BFD session is not
associated with a specific interface."
::= { hh3cBfdSessEntry 9 }
hh3cBfdSessRemoteAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable defines IP address of the remote interface
from which the BFD packets is transmitted.
It can also be used to enabled BFD on a specific
interface. The value is set to zero when BFD session is not
associated with a specific interface."
::= { hh3cBfdSessEntry 10 }
hh3cBfdSessLocalDiag OBJECT-TYPE
SYNTAX BfdDiag
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The BFD diagnostic code for the BFD session was down with the
neighbor. If no such event happens this object contains a zero
value."
DEFVAL { noDiagnostic }
::= { hh3cBfdSessEntry 11 }
hh3cBfdSessState OBJECT-TYPE
SYNTAX INTEGER {
adminDown(0),
down(1),
init(2),
up(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of the running BFD session.
There are three states through which a session normally
proceeds, two for establishing a session (Init and Up)
and one for tearing down a session (Down.) This allows
a three-way handshake for both session establishment and
session teardown (assuring that both systems are aware of
all session state changes.) A fourth state (AdminDown)
exists so that a session can be administratively put down
indefinitely.
The Down state means that the session is down (or has just been
created.) A session remains in Down state until the remote
system indicates that it agrees that the session is down by
sending a BFD Control packet with the State field set to
anything other than Up. If that packet signals Down state,
the session advances to Init state; if that packet signals
Init state, the session advances to Up state.
Init state means that the remote system is 0communicating,
and the local system desires to bring the session up, but
the remote system does not yet realize it. A session will
remain in Init state until either a BFD Control Packet is
received that is signaling Init or Up state (in which case
the session advances to Up state) or until the detection time
expires, meaning that communication with the remote system
has been lost (in which case the session advances to Down
state.)
Up state means that the BFD session has successfully been
established, and implies that connectivity between the systems
is working. The session will remain in the Up state until either
connectivity fails, or the session is taken down administratively.
If either the remote system signals Down state, or the detection
time expires, the session advances to Down state.
AdminDown state means that the session is being held
administratively down. This causes the remote system to enter
Down state, and remain there until the local system exits
AdminDown state."
DEFVAL { down }
::= { hh3cBfdSessEntry 12 }
hh3cBfdSessControlPlanIndepFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates whether the local system
can continue to work while the control plane is out
of work. Specifically, it is set to true(1) if the
local system is independent of the control plane. Otherwise,
the value is set to false(2)"
DEFVAL { true }
::= { hh3cBfdSessEntry 13 }
hh3cBfdSessAuthFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates that the local system wants
to use Authentication. Specifically, it is set
to true(1) if the local system wishes the session
to be authenticated or false(2) if not."
DEFVAL { false }
::= { hh3cBfdSessEntry 14 }
hh3cBfdSessDemandModeFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates that the local system wants
to use Demand mode. Specifically, it is set
to true(1) if the local system wishes to use
Demand mode or false(2) if not"
DEFVAL { false }
::= { hh3cBfdSessEntry 15 }
-- BFD Session State Table
hh3cBfdSessStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cBfdSessStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table defines BFD session state."
::= { hh3cBfdObjects 4 }
hh3cBfdSessStatEntry OBJECT-TYPE
SYNTAX Hh3cBfdSessStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table is created by a BFD-enabled node for
every BFD Session. It defines BFD session statistics."
AUGMENTS { hh3cBfdSessEntry }
::= { hh3cBfdSessStatTable 1 }
Hh3cBfdSessStatEntry ::= SEQUENCE {
hh3cBfdSessStatPktInHC Counter64,
hh3cBfdSessStatPktOutHC Counter64,
hh3cBfdSessStatDownCount Counter32,
hh3cBfdSessStatPktDiscard Counter64,
hh3cBfdSessStatPktLost Counter64
}
hh3cBfdSessStatPktInHC OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BFD messages received by this BFD
session."
::= { hh3cBfdSessStatEntry 1 }
hh3cBfdSessStatPktOutHC OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BFD messages sent by this BFD session."
::= { hh3cBfdSessStatEntry 2 }
hh3cBfdSessStatDownCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times this session has gone into the Down
state since the router last rebooted."
::= { hh3cBfdSessStatEntry 3 }
hh3cBfdSessStatPktDiscard OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets the local system has discarded
since the router last rebooted."
::= { hh3cBfdSessStatEntry 4 }
hh3cBfdSessStatPktLost OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets the local system has failed to transmit
since the router last rebooted."
::= { hh3cBfdSessStatEntry 5 }
-- BFD Session Performance Table
hh3cBfdSessPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cBfdSessPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table defines BFD session performance."
::= { hh3cBfdObjects 5 }
hh3cBfdSessPerfEntry OBJECT-TYPE
SYNTAX Hh3cBfdSessPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table is created by a BFD-enabled node for
every BFD session. It defines BFD Session performance."
AUGMENTS { hh3cBfdSessEntry }
::= { hh3cBfdSessPerfTable 1 }
Hh3cBfdSessPerfEntry ::= SEQUENCE {
hh3cBfdSessPerfCreatTime TimeStamp,
hh3cBfdSessPerfLastUpTime TimeStamp,
hh3cBfdSessPerfLastDownTime TimeStamp
}
hh3cBfdSessPerfCreatTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the session was created. If no such
create event exists this object contains a zero value."
::= { hh3cBfdSessPerfEntry 1 }
hh3cBfdSessPerfLastUpTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the last time communication was lost.
If no such up event exists this variable contains a zero value."
::= { hh3cBfdSessPerfEntry 2 }
hh3cBfdSessPerfLastDownTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the last time communication was lost
with the neighbor. If no such event exist this variable contains
a zero value."
::= { hh3cBfdSessPerfEntry 3 }
-- Notification Configuration
hh3cBfdSessName OBJECT-TYPE
SYNTAX Hh3cBfdSessionName
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"A name used to uniquely identify BFD sessions."
::= { hh3cBfdTrapBindObjects 1 }
hh3cBfdVpnInstanceName OBJECT-TYPE
SYNTAX Hh3cBfdBindVpnInstanceName
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The human-readable name of this VPN. This MAY
be equivalent to the [RFC2685] VPN-ID, but may
also vary. If it is set to the VPN ID, it MUST
be equivalent to the value of mplsL3VpnVrfVpnId.
It is strongly recommended that all sites supporting
VRFs that are part of the same VPN use the same
naming convention for VRFs as well as the same VPN
ID."
REFERENCE
"[RFC2685]"
::= { hh3cBfdTrapBindObjects 2 }
hh3cBfdLocalAddr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This variable defines IP address of the local interface
from which the BFD packets is transmitted.
It can also be used to enabled BFD on a specific
interface. The value is set to zero when BFD session is not
associated with a specific interface."
::= { hh3cBfdTrapBindObjects 3 }
hh3cBfdRemoteAddr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This variable defines IP address of the local interface
from which the BFD packets is transmitted.
It can also be used to enabled BFD on a specific
interface. The value is set to zero when BFD session is not
associated with a specific interface."
::= { hh3cBfdTrapBindObjects 4 }
hh3cBfdSessStateChange NOTIFICATION-TYPE
OBJECTS { hh3cBfdSessIfIndex,
hh3cBfdSessIndex,
hh3cBfdSessState
}
STATUS current
DESCRIPTION
"A notification sent when a session changes
state, entering state up or entering state down.
The session will enter state up finishing three times handshakes
, and will enter state down when the communication path is out
of work.
When the hh3cBfdSessState's value is state up, the session enters
state up, and the session enters state down when the
hh3cBfdSessState's value is state down.
The hh3cBfdSessIfIndex contains an interface's index under which
the BFD session runs.
The hh3cBfdSessIndex contains an index which represents a
unique BFD session on this device.
The hh3cBfdSessState is the state of the running BFD session.
"
::= { hh3cBfdNotifications 1 }
hh3cBfdSessAuthFail NOTIFICATION-TYPE
OBJECTS { hh3cBfdIfIndex
}
STATUS current
DESCRIPTION
"A notification sent when receiving a session
with an authentication fail.
The hh3cBfdIfIndex is an index which represents a unique BFD
interface on this device.
"
::= { hh3cBfdNotifications 2 }
hh3cBfdSessStateUp NOTIFICATION-TYPE
OBJECTS { hh3cBfdSessIfIndex,
hh3cBfdSessIndex,
hh3cBfdSessState,
hh3cBfdSessName,
hh3cBfdVpnInstanceName,
hh3cBfdLocalAddr,
hh3cBfdRemoteAddr
}
STATUS current
DESCRIPTION
"A notification sent when a session changes state to up.
The session will enter state up finishing three times handshakes.
The hh3cBfdSessIfIndex contains an interface's index under which
the BFD session runs.
The hh3cBfdSessIndex contains an index which represents a
unique BFD session on this device.
The hh3cBfdSessState is the state of the running BFD session.
The hh3cBfdSessName is the name of the running BFD session.
The hh3cBfdVpnInstanceName contains a VPN's name under which
the BFD session runs.
The hh3cBfdLocalAddr contains an IP address of the local interface
from which the BFD packets is transmitted.
The hh3cBfdRemoteAddr contains an IP address of the remote interface
from which the BFD packets is transmitted.
"
::= { hh3cBfdNotifications 3 }
hh3cBfdSessStateDown NOTIFICATION-TYPE
OBJECTS { hh3cBfdSessIfIndex,
hh3cBfdSessIndex,
hh3cBfdSessState,
hh3cBfdSessName,
hh3cBfdVpnInstanceName,
hh3cBfdLocalAddr,
hh3cBfdRemoteAddr
}
STATUS current
DESCRIPTION
"A notification sent when a session changes state to down.
The session will enter state down when the communication path is out
of work.
The hh3cBfdSessIfIndex contains an interface's index under which
the BFD session runs.
The hh3cBfdSessIndex contains an index which represents a
unique BFD session on this device.
The hh3cBfdSessState is the state of the running BFD session.
The hh3cBfdSessName is the name of the running BFD session.
The hh3cBfdVpnInstanceName contains a VPN's name under which
the BFD session runs.
The hh3cBfdLocalAddr contains an IP address of the local interface
from which the BFD packets is transmitted.
The hh3cBfdRemoteAddr contains an IP address of the remote interface
from which the BFD packets is transmitted.
"
::= { hh3cBfdNotifications 4 }
hh3cBfdSessReachLimit NOTIFICATION-TYPE
OBJECTS { hh3cBfdSessNumberLimit
}
STATUS current
DESCRIPTION
"A notification would be sent when the number of active BFD sessions
reached this device's upper limit and no more session could be
activated.
The hh3cBfdSessNumberLimit is the active session limit of this device."
::= { hh3cBfdNotifications 5 }
END