-- Copyright (c) 2004-2015 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: E1T1VI MIB
-- Reference:
-- Version: V1.3
-- History:
-- V1.0 2007-04-05 Initial Version by yandehan
-- V1.1 2009-06-08 modified by TONGWEI
-- Added hh3cE1T1VIUsingTimeslotsRatio
-- and hh3cE1T1VINotifications
-- V1.2 2010-04-08 modified by TONGWEI
-- Added hh3cE1T1VIGeneral
-- V1.3 2015-08-19 modified by YUHAIYAN
-- Added hh3cE1T1VITimeslotsUsedUpCount
-- and hh3cE1T1VITimeslotSampleInterval
-- and hh3cE1T1VIUsingTimeslotsPeak
-- and hh3cE1T1VITrapTimeSlotsThreshold
-- Modified hh3cE1T1VITrapTimeSlot
-- =============================================================
HH3C-E1T1VI-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, NOTIFICATION-TYPE
FROM SNMPv2-SMI
ifIndex ,ifDescr
FROM IF-MIB
hh3cCommon
FROM HH3C-OID-MIB;
-- =============================================================
-- E1T1VI Module
-- =============================================================
hh3cE1T1VI MODULE-IDENTITY
LAST-UPDATED "201508191800Z" -- Aug. 19, 2015 at 18:00 GMT
ORGANIZATION
"New H3C Technologies Co., Ltd."
CONTACT-INFO
"Platform Team New H3C Technologies Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip: 100085"
DESCRIPTION
"This MIB provides E1/T1 voice interface information that are
excluded by RFC 1213 and RFC 2233"
REVISION "201508191800Z"
DESCRIPTION
"Added hh3cE1T1VITimeslotsUsedUpCount
and hh3cE1T1VITimeslotSampleInterval
and hh3cE1T1VIUsingTimeslotsPeak
and hh3cE1T1VITrapTimeSlotThreshold
Modified hh3cE1T1VITrapTimeSlot"
REVISION "201004081855Z"
DESCRIPTION
"To fix bugs in the MIB file."
REVISION "200906081741Z"
DESCRIPTION
"To fix bugs in the MIB file."
REVISION "200704051542Z"
DESCRIPTION
"Initial version of this MIB module."
::= { hh3cCommon 76 }
hh3cE1T1VITable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cE1T1VIEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains E1/T1 voice interface information,
such as the total number of using time slot."
::= { hh3cE1T1VI 1 }
hh3cE1T1VIEntry OBJECT-TYPE
SYNTAX Hh3cE1T1VIEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry contains E1/T1 voice interface information.
The index of this Entry is ifIndex defined in ifTable
of RFC1213-MIB."
INDEX
{
ifIndex
}
::= { hh3cE1T1VITable 1 }
Hh3cE1T1VIEntry ::= SEQUENCE
{
hh3cE1T1VIUsingTimeslots Integer32,
hh3cE1T1VIUsingTimeslotsRatio Integer32,
hh3cE1T1VITimeslotsUsedUpCount Unsigned32,
hh3cE1T1VITimeslotSampleInterval Integer32,
hh3cE1T1VIUsingTimeslotsPeak Integer32,
hh3cE1T1VITrapTimeSlotsThreshold Integer32
}
hh3cE1T1VIUsingTimeslots OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of using time slots on this interface."
::= { hh3cE1T1VIEntry 1 }
hh3cE1T1VIUsingTimeslotsRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total ratio of using time slots on this interface."
::= { hh3cE1T1VIEntry 2 }
hh3cE1T1VITimeslotsUsedUpCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of times that all time slots were used up on this interface."
::= { hh3cE1T1VIEntry 3 }
hh3cE1T1VITimeslotSampleInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sampling interval in seconds for used time slots on this interface."
::= { hh3cE1T1VIEntry 4 }
hh3cE1T1VIUsingTimeslotsPeak OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peak number of used time slots in the entire sampling period on this interface."
::= { hh3cE1T1VIEntry 5 }
hh3cE1T1VITrapTimeSlotsThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the number of used time slots reaches the threshold, the hh3cE1T1VITrapTimeSlot trap will
be sent. The valid range is from 1 to total number of time slots on the interface."
::= { hh3cE1T1VIEntry 6 }
hh3cE1T1VINotifications OBJECT IDENTIFIER ::= { hh3cE1T1VI 2 }
hh3cE1T1VITrapPrefix OBJECT IDENTIFIER ::= { hh3cE1T1VINotifications 0 }
hh3cE1T1VITrapTimeSlot NOTIFICATION-TYPE
OBJECTS { ifIndex, ifDescr }
STATUS current
DESCRIPTION
"This trap is sent to the manager under the following
condition: The number of used time slots of an E1/T1
interface reaches the threshold."
::= { hh3cE1T1VITrapPrefix 1 }
hh3cE1T1VIGeneral OBJECT IDENTIFIER ::= { hh3cE1T1VI 3 }
hh3cE1T1VITrapTimeSlotEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute controls whether the hh3cE1T1VITrapTimeSlot trap will
be sent or not."
DEFVAL { enable }
::= { hh3cE1T1VIGeneral 1 }
END