-- Copyright (c) 2004-2016 New H3C Tech. Co., Ltd. All rights reserved.
|
|
--
|
|
-- Description:
|
|
-- Reference:
|
|
-- Version: V1.7
|
|
-- History:
|
|
-- V1.0 created by liujingya.
|
|
-- Initial version of the MIB
|
|
-- V1.1 2008-1-29 Adjusted the structure of some tables by liujingya.
|
|
-- V1.2 2008-5-19 Added hh3cHPEOCCltAutoUpgrade, hh3cHPEOCCnuAnonymStatus and
|
|
-- hh3cHPEOCBitPerSymbolTable, modified description of hh3cHPEOCCnuBcastControl
|
|
-- by liujingya.
|
|
-- V1.3 2009-2-13 Added hh3cHPEOCOnLineCnuNumber, hh3cHPEOCCpuMacAddress,
|
|
-- hh3cHPEOCOffLineCnuNumber, hh3cHPEOCDownLoadCNUFWResult,
|
|
-- hh3cHPEOCCltAutoUpgradeType, hh3cHPEOCServerAddress, hh3cHPEOCServerUser,
|
|
-- hh3cHPEOCServerPassword and hh3cHPEOCCnuMacLimit by liujingya.
|
|
-- V1.4 2011-12-28 Added hh3cHPEOCCltLinkState by gaoguangping.
|
|
-- 2012-03-14 Added hh3cHPEOCCltLoopbackDetect by gaoguangping.
|
|
-- V1.5 2013-08-20 Added hh3cHPEOCTemplate,hh3cHPEOCCnuAccess by xujun
|
|
-- 2013-09-16 Added hh3cHPEOCTemplateEnable by xujun
|
|
-- V1.6 2015-04-30 Bug fixed by songhao
|
|
-- V1.7 2016-09-02 Bug fixed by gaoguangping
|
|
-- =================================================================
|
|
HH3C-HPEOC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
hh3cCommon
|
|
FROM HH3C-OID-MIB
|
|
ifIndex
|
|
FROM IF-MIB
|
|
Integer32, Unsigned32, Counter64, OBJECT-TYPE, MODULE-IDENTITY,
|
|
IpAddress
|
|
FROM SNMPv2-SMI
|
|
DisplayString, TruthValue, MacAddress, RowStatus
|
|
FROM SNMPv2-TC;
|
|
|
|
|
|
hh3cHPEOC MODULE-IDENTITY
|
|
LAST-UPDATED "200708281008Z"
|
|
ORGANIZATION
|
|
"New H3C Tech. Co., Ltd."
|
|
CONTACT-INFO
|
|
"SMB EOC Team New H3C Technologies Co., Ltd.
|
|
Shang-Di Information Industry Base,
|
|
Hai-Dian District Beijing P.R. China
|
|
http://www.h3c.com
|
|
Zip:310053."
|
|
DESCRIPTION
|
|
"
|
|
The objects in this MIB module are used to manage and
|
|
display current configuration of Ethernet Over Cable
|
|
Network (EOC) which based on HomePlug(HP) AV Specification.
|
|
"
|
|
::= { hh3cCommon 84 }
|
|
|
|
--
|
|
-- hh3cHPEOCSystem
|
|
--
|
|
hh3cHPEOCSystem OBJECT IDENTIFIER ::= { hh3cHPEOC 1 }
|
|
|
|
hh3cHPEOCCltVlanType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ieee8021q(1),
|
|
portbased(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Control EOC CLT's VLAN type,
|
|
ieee8021q : 802.1q VLAN mode,
|
|
portbased : portbased VLAN mode.
|
|
"
|
|
::= { hh3cHPEOCSystem 1 }
|
|
|
|
--
|
|
-- hh3cHPEOCCltVlanManTable
|
|
--
|
|
hh3cHPEOCCltVlanManTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCCltVlanManEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table implements the management of CLT(Coax Line Terminal)
|
|
VLAN.
|
|
"
|
|
::= { hh3cHPEOCSystem 2 }
|
|
|
|
hh3cHPEOCCltVlanManEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCCltVlanManEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCCltVlanManTable.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hh3cHPEOCCltVlanManTable 1 }
|
|
|
|
Hh3cHPEOCCltVlanManEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCCltEthPortType INTEGER
|
|
}
|
|
|
|
hh3cHPEOCCltEthPortType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(1),
|
|
debug(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Control CLT ethernet ports' type,
|
|
normal : port which used for normal translation,
|
|
debug : port which used for debug.
|
|
"
|
|
::= { hh3cHPEOCCltVlanManEntry 1 }
|
|
|
|
--
|
|
-- hh3cHPEOCCltSysManTable
|
|
--
|
|
hh3cHPEOCCltSysManTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCCltSysManEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table implements the management of CLT(Coax Line Terminal).
|
|
"
|
|
::= { hh3cHPEOCSystem 3 }
|
|
|
|
hh3cHPEOCCltSysManEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCCltSysManEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCCltSysManTable.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hh3cHPEOCCltSysManTable 1 }
|
|
|
|
Hh3cHPEOCCltSysManEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCCltDescr DisplayString,
|
|
hh3cHPEOCCltFwVersion DisplayString,
|
|
hh3cHPEOCCltLinkState INTEGER
|
|
}
|
|
|
|
hh3cHPEOCCltDescr OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..126))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Set the description of CLT.
|
|
"
|
|
::= { hh3cHPEOCCltSysManEntry 1 }
|
|
|
|
hh3cHPEOCCltFwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
EOC firmware version. If the object length is
|
|
zero, it means the version is unknown.
|
|
"
|
|
::= { hh3cHPEOCCltSysManEntry 2 }
|
|
|
|
hh3cHPEOCCltLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
physicaldown(1),
|
|
linkdown(2),
|
|
linkup(3),
|
|
loopback(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable port's link state. The physicaldown(1) state indicates
|
|
that the CLT is not powered on. The linkdown(2) state indicates
|
|
that the CLT is powered on, but registers fail. The linkup(3)
|
|
state indicates that the CLT is powered on, and registers
|
|
successful. The loopback(4) state indecates that the CLT is
|
|
powered on and registers successful, but loopback has detected.
|
|
"
|
|
::= { hh3cHPEOCCltSysManEntry 3 }
|
|
|
|
--
|
|
-- hh3cHPEOCCnuSysManTable
|
|
--
|
|
hh3cHPEOCCnuSysManTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCCnuSysManEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table implements the management of CNUs.
|
|
"
|
|
::= { hh3cHPEOCSystem 4 }
|
|
|
|
hh3cHPEOCCnuSysManEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCCnuSysManEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCCnuSysManTable.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hh3cHPEOCCnuSysManTable 1 }
|
|
|
|
Hh3cHPEOCCnuSysManEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCCnuBcastControl TruthValue,
|
|
hh3cHPEOCCnuAnonymStatus TruthValue,
|
|
hh3cHPEOCCnuMacLimit Unsigned32
|
|
}
|
|
|
|
hh3cHPEOCCnuBcastControl OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Broadcast storm suppression status.
|
|
true(1) - Broadcast storm suppression enable.
|
|
false(2) - Broadcast storm suppression disable.
|
|
"
|
|
::= { hh3cHPEOCCnuSysManEntry 1 }
|
|
|
|
hh3cHPEOCCnuAnonymStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Anonymity status.
|
|
true(1) - the user which uses the CNU is anonymous.
|
|
false(2) - the user which uses the CNU has an account.
|
|
"
|
|
::= { hh3cHPEOCCnuSysManEntry 2 }
|
|
|
|
hh3cHPEOCCnuMacLimit OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Configure the max number of MAC address entries which can access
|
|
through the CNU, it ranges from 1 to 8.
|
|
Otherwise,
|
|
If configure 0, the CNU won't limit the MAC address entry.
|
|
If configure 0xFF, it means no MAC address entry can access the CNU.
|
|
"
|
|
::= { hh3cHPEOCCnuSysManEntry 3 }
|
|
|
|
hh3cHPEOCCltAutoUpgrade OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Auto upgrade Status.
|
|
true(1) - The firmware of the CNU will be auto changed by CLT.
|
|
false(2)- The firmware of the CNU will not be auto changed.
|
|
"
|
|
DEFVAL
|
|
{
|
|
false
|
|
}
|
|
::= { hh3cHPEOCSystem 5 }
|
|
|
|
hh3cHPEOCOnLineCnuNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The total number of the online CNU(s).
|
|
"
|
|
::= { hh3cHPEOCSystem 6 }
|
|
|
|
hh3cHPEOCCpuMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
EOC CPU's MAC address.
|
|
"
|
|
::= { hh3cHPEOCSystem 7 }
|
|
|
|
hh3cHPEOCOffLineCnuNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The total number of the offline CNU(s).
|
|
"
|
|
::= { hh3cHPEOCSystem 8 }
|
|
|
|
hh3cHPEOCDownLoadCNUFWResult OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Download CNU firmware result.
|
|
"
|
|
::= { hh3cHPEOCSystem 9 }
|
|
|
|
hh3cHPEOCCltAutoUpgradeType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
flash(1),
|
|
ftp(2),
|
|
tftp(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Type of auto upgrade status.
|
|
It depends on hh3cHPEOCCltAutoUpgrade status.
|
|
flash - The CLT auto upgrade the firmware inside its flash
|
|
to the CNUs.
|
|
ftp - First download the firmware from FTP server to the CLT,
|
|
then the CLT auto upgrade the firmware to the CNUs.
|
|
tftp - First download the firmware from TFTP server to the CLT,
|
|
then the CLT auto upgrade the firmware to the CNUs.
|
|
"
|
|
::= { hh3cHPEOCSystem 10 }
|
|
|
|
hh3cHPEOCAutoUpObjects OBJECT IDENTIFIER ::= { hh3cHPEOCSystem 11 }
|
|
|
|
hh3cHPEOCServerAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The address of remote host acting as server for operation.
|
|
The default value is 0.0.0.0
|
|
"
|
|
::= { hh3cHPEOCAutoUpObjects 1 }
|
|
|
|
hh3cHPEOCServerUser OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
When using ftp to transfer files, the user name must be
|
|
specified through this node. It contains 1 to 30 characters.
|
|
"
|
|
::= { hh3cHPEOCAutoUpObjects 2 }
|
|
|
|
hh3cHPEOCServerPassword OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Remote user password for copying via ftp protocol. Optionally,
|
|
this object may be ignored for protocols other than ftp.
|
|
It contains 1 to 31 characters.
|
|
"
|
|
::= { hh3cHPEOCAutoUpObjects 3 }
|
|
|
|
hh3cHPEOCCltLoopbackDetect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
false(0),
|
|
true(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Loopback detect Status.
|
|
true(1) - The loopback detect is enabled.
|
|
false(0)- The loopback detect is disabled.
|
|
"
|
|
::= { hh3cHPEOCSystem 12 }
|
|
|
|
hh3cHPEOCTemplateEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
false(0),
|
|
true(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Use template for white-list cnu.
|
|
true(1) - Use template is enabled.
|
|
false(0)- Use template detect is disabled.
|
|
"
|
|
::= { hh3cHPEOCSystem 13 }
|
|
|
|
--
|
|
-- hh3cHPEOCCableInfo
|
|
--
|
|
hh3cHPEOCCableInfo OBJECT IDENTIFIER ::= { hh3cHPEOC 2 }
|
|
|
|
|
|
--
|
|
-- hh3cHPEOCCableInfoTable
|
|
--
|
|
|
|
hh3cHPEOCCableInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCCableInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table defines the primary parameters of the
|
|
cable information.
|
|
"
|
|
::= { hh3cHPEOCCableInfo 1 }
|
|
|
|
hh3cHPEOCCableInfoEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCCableInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCCableInfoTable.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex
|
|
}
|
|
::= { hh3cHPEOCCableInfoTable 1 }
|
|
|
|
|
|
Hh3cHPEOCCableInfoEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCFECErrors Counter64,
|
|
hh3cHPEOCAvgBitsPerCarrier Unsigned32,
|
|
hh3cHPEOCAvgSNRPerCarrier Integer32,
|
|
hh3cHPEOCAvgInPBCRCErrors Unsigned32,
|
|
hh3cHPEOCInTotalPkts Counter64,
|
|
hh3cHPEOCAvgOutPower Integer32,
|
|
hh3cHPEOCAvgOutPBCRCErrors Unsigned32,
|
|
hh3cHPEOCOutTotalPkts Counter64
|
|
}
|
|
|
|
hh3cHPEOCFECErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable port's FEC bits errors ratio. FEC means the
|
|
payload Forward Error Correction. It's a technology of
|
|
controlling errors. Packets in transmission is checked by
|
|
the receiver, if error occurs, the receiver will announce
|
|
the sender to resend.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 1 }
|
|
|
|
hh3cHPEOCAvgBitsPerCarrier OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable port's average bits per carrier.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 2 }
|
|
|
|
hh3cHPEOCAvgSNRPerCarrier OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable port's signal noise ratio(SNR) bits per carrier.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 3 }
|
|
|
|
hh3cHPEOCAvgInPBCRCErrors OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The input PB CRC errors on average.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 4 }
|
|
|
|
hh3cHPEOCInTotalPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The total number of packets(including bad packets)
|
|
received on this interface.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 5 }
|
|
|
|
hh3cHPEOCAvgOutPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable port's power sent on average, the unit is db.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 6 }
|
|
|
|
hh3cHPEOCAvgOutPBCRCErrors OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable port's physical block(PB) cyclic redundancy
|
|
check(CRC) errors sent on average.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 7 }
|
|
|
|
hh3cHPEOCOutTotalPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The total count of the packets(including bad packets)
|
|
sent on this interface.
|
|
"
|
|
::= { hh3cHPEOCCableInfoEntry 8 }
|
|
|
|
--
|
|
-- hh3cHPEOCBitPerSymbolTable
|
|
--
|
|
|
|
hh3cHPEOCBitPerSymbolTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCBitPerSymbolEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table defines the bits per symbol parameters of the
|
|
cable line.
|
|
"
|
|
::= { hh3cHPEOCCableInfo 2 }
|
|
|
|
hh3cHPEOCBitPerSymbolEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCBitPerSymbolEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCBitPerSymbolTable.
|
|
"
|
|
INDEX
|
|
{
|
|
ifIndex,
|
|
hh3cHPEOCBitPerSymbolIndex
|
|
}
|
|
::= { hh3cHPEOCBitPerSymbolTable 1 }
|
|
|
|
Hh3cHPEOCBitPerSymbolEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCBitPerSymbolIndex Unsigned32,
|
|
hh3cHPEOCBitPerSymbol OCTET STRING
|
|
}
|
|
|
|
hh3cHPEOCBitPerSymbolIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The index of the hh3cHPEOCBitPerSymbolTable.
|
|
"
|
|
::= { hh3cHPEOCBitPerSymbolEntry 1 }
|
|
|
|
hh3cHPEOCBitPerSymbol OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
hh3cHPEOCBitPerSymbol returns all the bits per symbol on the fixed
|
|
frequency. Each 4 bits stand for one value, all the values
|
|
picking-up will make up a cable bit map.
|
|
"
|
|
::= { hh3cHPEOCBitPerSymbolEntry 2 }
|
|
|
|
--
|
|
-- hh3cHPEOCTemplate
|
|
--
|
|
|
|
hh3cHPEOCTemplate OBJECT IDENTIFIER ::= { hh3cHPEOC 3 }
|
|
|
|
--
|
|
-- hh3cHPEOCTemplateGlobalTable
|
|
--
|
|
|
|
hh3cHPEOCTemplateGlobalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCTemplateGlobalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table defines the global parameters of the
|
|
Template information.
|
|
"
|
|
::= { hh3cHPEOCTemplate 1 }
|
|
|
|
hh3cHPEOCTemplateGlobalEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCTemplateGlobalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCTemplateGlobalTable.
|
|
"
|
|
INDEX
|
|
{
|
|
hh3cHPEOCTemplateIndex
|
|
}
|
|
::= { hh3cHPEOCTemplateGlobalTable 1 }
|
|
|
|
Hh3cHPEOCTemplateGlobalEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCTemplateIndex Integer32,
|
|
hh3cHPEOCTemplateType Integer32,
|
|
hh3cHPEOCTemplateName DisplayString,
|
|
hh3cHPEOCTemplateDescr DisplayString,
|
|
hh3cHPEOCTemplateCnuMaxDownBW Integer32,
|
|
hh3cHPEOCTemplateCnuMaxUpBW Integer32,
|
|
hh3cHPEOCTemplateCnuBcastControl TruthValue,
|
|
hh3cHPEOCTemplateCnuMacLimit Unsigned32,
|
|
hh3cHPEOCTemplateCb201VlanEn TruthValue,
|
|
hh3cHPEOCTemplateRowStatus RowStatus
|
|
}
|
|
|
|
hh3cHPEOCTemplateIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The index of cable Template.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 1 }
|
|
|
|
hh3cHPEOCTemplateType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
switch(1),
|
|
gateway(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable Template's type, can not change after create it.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 2 }
|
|
|
|
hh3cHPEOCTemplateName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable Template's name, it's recommended to set it
|
|
uniquely and understandably. Length: 1 to 15 characters.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 3 }
|
|
|
|
hh3cHPEOCTemplateDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The cable Template's description. Length: 0 to 63 characters.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 4 }
|
|
|
|
hh3cHPEOCTemplateCnuMaxDownBW OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Maximum downstream bandwidth allowed for the CNU,
|
|
measured in Kbit/s, ranges from 0 to 16384, and must be multiples of 64.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 5 }
|
|
|
|
hh3cHPEOCTemplateCnuMaxUpBW OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Maximum upstream bandwidth allowed for the CNU,
|
|
measured in Kbit/s, ranges from 0 to 16384, and must be multiples of 64.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 6 }
|
|
|
|
hh3cHPEOCTemplateCnuBcastControl OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Broadcast storm suppression status.
|
|
true(1) - Broadcast storm suppression enable.
|
|
false(2) - Broadcast storm suppression disable.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 7 }
|
|
|
|
hh3cHPEOCTemplateCnuMacLimit OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Configure the max number of MAC address entries which can access
|
|
through the CNU, it ranges from 1 to 8.
|
|
Otherwise,
|
|
If configure 0, the CNU won't limit the MAC address entry.
|
|
If configure 0xFF, it means no MAC address entry can access the CNU.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 8 }
|
|
|
|
hh3cHPEOCTemplateCb201VlanEn OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Use for Cb201 cnu only.
|
|
true(1) - Enable vlan insert function.
|
|
false(2) - Disable vlan insert function.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 9 }
|
|
|
|
hh3cHPEOCTemplateRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Operation status.
|
|
"
|
|
::= { hh3cHPEOCTemplateGlobalEntry 10 }
|
|
|
|
--
|
|
-- hh3cHPEOCTemplateSwitchTable
|
|
--
|
|
|
|
hh3cHPEOCTemplateSwitchTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCTemplateSwitchEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table defines the port parameters of the
|
|
switch type cnu. it's not affect on the type of gateway Template.
|
|
"
|
|
::= { hh3cHPEOCTemplate 2 }
|
|
|
|
hh3cHPEOCTemplateSwitchEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCTemplateSwitchEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCTemplateSwitchTable.
|
|
"
|
|
INDEX
|
|
{
|
|
hh3cHPEOCTemplateIndex,
|
|
hh3cHPEOCTemplateUniIndex
|
|
}
|
|
::= { hh3cHPEOCTemplateSwitchTable 1 }
|
|
|
|
Hh3cHPEOCTemplateSwitchEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCTemplateUniIndex Integer32,
|
|
hh3cHPEOCTemplateUniSpeed INTEGER,
|
|
hh3cHPEOCTemplateUniDuplex INTEGER,
|
|
hh3cHPEOCTemplateUniPriority Integer32,
|
|
hh3cHPEOCTemplateUniFlowControl TruthValue,
|
|
hh3cHPEOCTemplateUniUpLineRate Unsigned32,
|
|
hh3cHPEOCTemplateUniDownLineRate Unsigned32,
|
|
hh3cHPEOCTemplateUniAdminStatus INTEGER,
|
|
hh3cHPEOCTemplateUniVLANType INTEGER,
|
|
hh3cHPEOCTemplateUniPvid Integer32,
|
|
hh3cHPEOCTemplateUniVlanTag INTEGER
|
|
}
|
|
|
|
hh3cHPEOCTemplateUniIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The index value which uniquely identifies the FE
|
|
interface of the CNU.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 1 }
|
|
|
|
hh3cHPEOCTemplateUniSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
auto(1),
|
|
s10M(10),
|
|
s100M(100)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
User network interface speed.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 2 }
|
|
|
|
hh3cHPEOCTemplateUniDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full(1),
|
|
half(2),
|
|
auto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
User network interface mode.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 3 }
|
|
|
|
hh3cHPEOCTemplateUniPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The default ingress User Priority for this port. This
|
|
only has effect on media, such as Ethernet, that do not
|
|
support native User Priority.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 4 }
|
|
|
|
hh3cHPEOCTemplateUniFlowControl OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Flow control status.
|
|
true(1) - Flow control status enable.
|
|
false(2) - Flow control status disable."
|
|
DEFVAL
|
|
{
|
|
false
|
|
}
|
|
::= { hh3cHPEOCTemplateSwitchEntry 5 }
|
|
|
|
hh3cHPEOCTemplateUniUpLineRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The max speed upload in units of 1,024 bits per second
|
|
on this interface. The value should between 0 and 8Mbps.
|
|
If the value is 0, it means that the upload speed is only
|
|
restricted by the physical line.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 6 }
|
|
|
|
hh3cHPEOCTemplateUniDownLineRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The max speed download in units of 1,024 bits per second
|
|
on this interface. The value should between 0 and 8Mbps.
|
|
If the value is 0, it means that the download speed is only
|
|
restricted by the physical line.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 7 }
|
|
|
|
hh3cHPEOCTemplateUniAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Control if open or close the UNI. If choose up(1), means the UNI is
|
|
opened and packets can pass it. If choose down(2), means the UNI is
|
|
closed and all packets will be discard.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 8 }
|
|
|
|
hh3cHPEOCTemplateUniVLANType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
access(1),
|
|
trunk(2),
|
|
hybrid(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"port vlan types.
|
|
hybrid (3) port can carry multiple VLANs.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 9 }
|
|
|
|
hh3cHPEOCTemplateUniPvid OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4094)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The PVID, the VLAN ID assigned to untagged frames or
|
|
Priority-Tagged frames received on this port.
|
|
"
|
|
REFERENCE
|
|
"
|
|
IEEE 802.1Q/D11 Section 12.10.1.1
|
|
"
|
|
DEFVAL
|
|
{
|
|
1
|
|
}
|
|
::= { hh3cHPEOCTemplateSwitchEntry 10 }
|
|
|
|
hh3cHPEOCTemplateUniVlanTag OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
tagged(1),
|
|
untagged(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
VLAN is set tagged or untagged.
|
|
"
|
|
::= { hh3cHPEOCTemplateSwitchEntry 11 }
|
|
|
|
--
|
|
-- hh3cHPEOCCnuAccess
|
|
--
|
|
hh3cHPEOCCnuAccess OBJECT IDENTIFIER ::= { hh3cHPEOC 4 }
|
|
|
|
--
|
|
-- hh3cHPEOCCnuAccessTable
|
|
--
|
|
|
|
hh3cHPEOCCnuAccessTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Hh3cHPEOCCnuAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This table defines the global parameters of the
|
|
cnu type permitting to access.
|
|
"
|
|
::= { hh3cHPEOCCnuAccess 1 }
|
|
|
|
hh3cHPEOCCnuAccessEntry OBJECT-TYPE
|
|
SYNTAX Hh3cHPEOCCnuAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The entry of the table hh3cHPEOCCnuAccessTable.
|
|
"
|
|
INDEX
|
|
{
|
|
hh3cHPEOCCnuAccessIndex
|
|
}
|
|
::= { hh3cHPEOCCnuAccessTable 1 }
|
|
|
|
|
|
Hh3cHPEOCCnuAccessEntry ::= SEQUENCE
|
|
{
|
|
hh3cHPEOCCnuAccessIndex Integer32,
|
|
hh3cHPEOCCnuHFID DisplayString,
|
|
hh3cHPEOCManuInfo DisplayString,
|
|
hh3cHPEOCCnuType Integer32,
|
|
hh3cHPEOCCnuSwitchType Integer32,
|
|
hh3cHPEOCCnuUniNum Integer32,
|
|
hh3cHPEOCCnuPhy2Uni OCTET STRING,
|
|
hh3cHPEOCCnuAccessRowStatus RowStatus
|
|
}
|
|
|
|
hh3cHPEOCCnuAccessIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The index value which uniquely identifies the
|
|
manuinfo of the CNU.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 1 }
|
|
|
|
hh3cHPEOCCnuHFID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The Cnu's HFID. Every type Cnu has it's unique HFID.
|
|
Length: 1 to 64 characters.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 2 }
|
|
|
|
hh3cHPEOCManuInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The Cnu's manufactory infofamiont.
|
|
Length: 0 to 63 characters.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 3 }
|
|
|
|
hh3cHPEOCCnuType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
switch(1),
|
|
gateway(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The Cnu's function type.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 4 }
|
|
|
|
hh3cHPEOCCnuSwitchType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rtl8306e(1),
|
|
ar8236(2),
|
|
mv6061(3),
|
|
mv6031(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The Cnu's switch chip type. It's useless for gataway type cnu.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 5 }
|
|
|
|
hh3cHPEOCCnuUniNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Uni number of the Cnu. It's useless for gataway type cnu.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 6 }
|
|
|
|
hh3cHPEOCCnuPhy2Uni OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Reflection from phy port to uni port of the cnu.
|
|
It's useless for gataway type cnu.
|
|
For example, phy port 0,1,2,3 is reflect to uni port
|
|
1,2,3,4, then the value of this mib is {0,1,2,3}
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 7 }
|
|
|
|
hh3cHPEOCCnuAccessRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Operation status.
|
|
"
|
|
::= { hh3cHPEOCCnuAccessEntry 8 }
|
|
|
|
END
|