mibs/MIBS/comware/HH3C-NET-MAN-MIB
2023-12-05 12:25:34 +01:00

190 lines
6.4 KiB
Plaintext

-- ==========================================================================
-- Copyright (C) 2008 by New H3C Technologies Co., Ltd. All rights reserved.
--
-- Description: The purpose of this MIB file is to provide object definition
-- of network management parameters.
-- Reference:
-- Version: V1.0
-- History:
-- V1.0 2008-04-16 Initial version, created by Longyin
-- ==========================================================================
HH3C-NET-MAN-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF
InetAddressType, InetAddress
FROM INET-ADDRESS-MIB
hh3cCommon
FROM HH3C-OID-MIB;
hh3cNetMan MODULE-IDENTITY
LAST-UPDATED "200804161700Z"
ORGANIZATION
"New H3C Technologies Co., Ltd."
CONTACT-INFO
"Platform Team New H3C Technologies Co., Ltd.
Hai-Dian District Beijing P.R. China
Http://www.h3c.com
Zip: 100085"
DESCRIPTION
"This MIB file is to provide the object definition of the network
management parameters. These parameters are used to identify devices.
It is useful for devices management in a dynamic address assignment
network."
REVISION "200804161700Z"
DESCRIPTION
"The initial version of this MIB file."
::= { hh3cCommon 90 }
--
-- Object definitions
--
hh3cNMConfigObjects OBJECT IDENTIFIER ::= { hh3cNetMan 1 }
hh3cNMMonitorObjects OBJECT IDENTIFIER ::= { hh3cNetMan 2 }
hh3cNMNotify OBJECT IDENTIFIER ::= { hh3cNetMan 3 }
-- Scalar Objects for Notify
hh3cNMNotifyScalarObjects OBJECT IDENTIFIER ::= { hh3cNMNotify 1 }
hh3cNMIpAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The IP address type of specified interface on the device."
::= { hh3cNMNotifyScalarObjects 1 }
hh3cNMIpAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The IP address of specified interface on the device."
::= { hh3cNMNotifyScalarObjects 2 }
hh3cNMCustomBuildInfo OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The customer-required information of devices, for example,
OUI (Organizational Unique Identifier)."
::= { hh3cNMNotifyScalarObjects 3 }
hh3cNMSerialNum OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..64))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The serial number used by NMS (Network Management Station) for
mapping IP address and device."
::= { hh3cNMNotifyScalarObjects 4 }
-- Notification Objects
hh3cNMNotifyObjects OBJECT IDENTIFIER ::= { hh3cNMNotify 2 }
hh3cNMNotifyObjectsPrefix OBJECT IDENTIFIER ::= { hh3cNMNotifyObjects 0 }
hh3cIpAddrChangeNotify NOTIFICATION-TYPE
OBJECTS
{
hh3cNMIpAddressType,
hh3cNMIpAddress,
hh3cNMCustomBuildInfo,
hh3cNMSerialNum
}
STATUS current
DESCRIPTION
"This notification will be generated when the IP address of active
management interface is changed. The change maybe originate from NMS,
DHCP server or administrator.
The management interfaces are the interfaces that assigned by
administrator, which can be used to manage device, but may be inactive
for link fault or IP address (IPv4 or IPv6) missing.
The active management interface means an active interface, the IP
address of which can be used for network management.
This notification announces useful management IP address change. So it
is triggered by significative IP address change.
Suppose that two management interfaces on a device, Interface-A and
Interface-B. Initially both interfaces are down and assigned no IP
address. Configure Interface-A as the primary monitored interface,
Interface-B as the secondary.
Significative IP address change in following cases:
1. If Interface-A is assigned an IP address primarily, and it is linking
up, then Interface-B will be ignored. A notification will be triggered,
appending IP address of Interface-A.
2. If Interface-B is assigned an IP address primarily, and it is linking
up, then Interface-A will be ignored. A notification will be triggered,
appending IP address of Interface-B.
3. If IP address of that interface, which had its IP address announced
to NMS, is changed since last notification triggered, then another
notification will be sent to NMS.
4. Suppore that Interface-A was linked up and assigned an IP address
primarily. If for some unknown reason, Interface-A is down or loses IP
address, and Interface-B is assigned an IP address which is different
with that announced to NMS before, then a notification will be
triggered, appending the new IP address that Interface-B assigned.
5. A notification appending new IP address that Interface-A assigned
will be triggered, if 4 occurs to Interface-B."
::= { hh3cNMNotifyObjectsPrefix 1 }
-- Compliances Objects
hh3cNetManConformance OBJECT IDENTIFIER ::= { hh3cNetMan 4 }
hh3cNetManCompliances OBJECT IDENTIFIER ::= { hh3cNetManConformance 1 }
hh3cNetManCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The statement of compliance for those implementing
the network management MIB."
MODULE
MANDATORY-GROUPS
{
hh3cNMMonitorGroup,
hh3cNMNotificationGroup
}
::= { hh3cNetManCompliances 1 }
hh3cNetManGroups OBJECT IDENTIFIER ::= { hh3cNetManConformance 2 }
hh3cNMMonitorGroup OBJECT-GROUP
OBJECTS
{
hh3cNMIpAddressType,
hh3cNMIpAddress,
hh3cNMCustomBuildInfo,
hh3cNMSerialNum
}
STATUS current
DESCRIPTION
"A collection of objects in net management monitor group."
::= { hh3cNetManGroups 1 }
hh3cNMNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS
{
hh3cIpAddrChangeNotify
}
STATUS current
DESCRIPTION
"A collection of objects in net management notification group."
::= { hh3cNetManGroups 2 }
END