mibs/MIBS/comware/HH3C-STACK-MIB
2023-12-05 12:25:34 +01:00

641 lines
20 KiB
Plaintext

-- =================================================================
-- Copyright (c) 2004-2021 New H3C Tech. Co., Ltd. All rights reserved
--
-- Description: stack mib
-- Reference: STACK-MIB
-- Version: V1.5
-- History:
-- V1.0 Created by ranbin
-- Initial version 2008-04-30
-- V1.1 2012-02-24 Modified by zhengwei
-- Changed the range of link delay to 0 to 30000 ms
-- V1.2 2013-08-16 Updated by wangpengju
-- Added node hh3cStackPortForwardingPath to hh3cStackPortInfoTable
-- 2013-10-23 Updated by zhengwei
-- Added notification nodes because MAD group work status changed:
-- hh3cStackMadBfdChangeNormal
-- hh3cStackMadBfdChangeFailure
-- hh3cStackMadLacpChangeNormal
-- hh3cStackMadLacpChangeFailure
-- V1.3 2014-08-11 Updated by SongHao
-- Added hh3cStackDomainId
-- 2014-11-20 Updated by songhao
-- Added hh3cStackPortConfigActivate in hh3cStackGlobalConfig.
-- hh3cStackLinkDelayInterval was changed to in the range of 0 to 2147483647 ms
-- V1.4 2020-03-03 Updated by zhangwenbo
-- Added notification node hh3cStackPhysicalIntfLinkUp
-- Added notification node hh3cStackPhysicalIntfLinkDown
-- Added hh3cStackPhysicalIntfName
-- V1.5 2021-03-17 Updated by meishenhe
-- Added notification node hh3cStackPhysicalIntfRxTimeout
-- =================================================================
HH3C-STACK-MIB DEFINITIONS ::= BEGIN
IMPORTS
hh3cCommon
FROM HH3C-OID-MIB
entPhysicalIndex
FROM ENTITY-MIB
ifIndex, ifDescr
FROM IF-MIB
Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Unsigned32
FROM SNMPv2-SMI;
hh3cStack MODULE-IDENTITY
LAST-UPDATED "202103250943Z"
ORGANIZATION
"New H3C Technologies Co., Ltd."
CONTACT-INFO
"Platform Team New H3C Technologies Co., Ltd.
Hai-Dian District Beijing P.R. China
Http://www.h3c.com
Zip:100085"
DESCRIPTION
"This MIB is used to manage STM (Stack Topology Management)
information for IRF (Intelligent Resilient Framework) device.
This MIB is applicable to IRF-capable products. Some objects in
this MIB may be used only for some specific products, so users should
refer to the related documents to acquire more detailed information."
REVISION "202103250943Z"
DESCRIPTION
"Added notification node hh3cStackPhysicalIntfRxTimeout."
REVISION "201411200850Z"
DESCRIPTION
"Added hh3cStackPortConfigActivate in hh3cStackGlobalConfig.
hh3cStackLinkDelayInterval was changed to in the range of 0 to
2147483647 ms."
REVISION "201408110641Z"
DESCRIPTION
"Added hh3cStackDomainId."
REVISION "201310230000Z"
DESCRIPTION
"Added notification nodes because MAD group work status changed:
hh3cStackMadBfdChangeNormal
hh3cStackMadBfdChangeFailure
hh3cStackMadLacpChangeNormal
hh3cStackMadLacpChangeFailure"
REVISION "201308160000Z"
DESCRIPTION
"Added node hh3cStackPortForwardingPath to hh3cStackPortInfoTable."
REVISION "201202240000Z"
DESCRIPTION
"Changed the range of link delay to 0 to 30000 ms."
REVISION "200804301650Z" -- 30th April, 2007 at 16:50 GMT
DESCRIPTION
"The initial revision of this MIB module."
::= { hh3cCommon 91 }
-- Scalar MIB objects, which are considered as global variables
-- Global Level Configuration
hh3cStackGlobalConfig OBJECT IDENTIFIER ::= { hh3cStack 1 }
hh3cStackMaxMember OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of members in a stack."
::= { hh3cStackGlobalConfig 1 }
hh3cStackMemberNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of members currently in a stack."
::= { hh3cStackGlobalConfig 2 }
hh3cStackMaxConfigPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest priority that can be configured for a member in a stack."
::= { hh3cStackGlobalConfig 3 }
hh3cStackAutoUpdate OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
enabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The function for automatically updating the image from the master to
a device that is attempting to join the stack.
When a new device tries to join a stack, STM verifies the image
consistency between the joining device and the master.
If the joining device uses a different image version than the master,
the function updates the joining device with the image of the master.
When this function is disabled, the new device can't join the stack
if it uses a different software version than the master.
disabled: disable auto update function
enabled: enable auto update function"
::= { hh3cStackGlobalConfig 4 }
hh3cStackMacPersistence OBJECT-TYPE
SYNTAX INTEGER
{
notPersist(1),
persistForSixMin(2),
persistForever(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mode of bridge MAC address persistence. When a stack starts,
the bridge MAC address of the master is used as that of the stack.
When the master leaves the stack, the bridge MAC address of the
stack changes depending on the mode of bridge MAC address persistence.
notPersist: The bridge MAC address of the new master is used
as that of the stack immediately.
persistForSixMin: The original bridge MAC address will be reserved for six
minutes. In this period, if the master that has left rejoins the stack,
the bridge MAC address of the stack will not change.
If the old master doesn't rejoin the stack within this period, the
bridge MAC address of the new master will be used as that of the stack.
persistForever: Whether the master leaves or not, the bridge MAC address
of the stack will never change."
::= { hh3cStackGlobalConfig 5 }
hh3cStackLinkDelayInterval OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "millisecond"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Delay for stack ports to report a link down event. If the link comes up
before the delay timer expires, the stack port will not report the link
down event. If the link is not recovered before the delay timer expires,
the stack port will report the change. If the delay is set to 0,
the stack ports will report a link down event without delay.
0: no delay
other value(ms): delay time"
::= { hh3cStackGlobalConfig 6 }
hh3cStackTopology OBJECT-TYPE
SYNTAX INTEGER
{
chainConn(1),
ringConn(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Stack topology.
chainConn: daisy-chain connection
ringConn: ring connection"
::= { hh3cStackGlobalConfig 7 }
hh3cStackDomainId OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Domain ID of the IRF fabric that is used to uniquely identify an IRF fabric.
Domain IDs prevent IRF fabrics from interfering with one another."
::= { hh3cStackGlobalConfig 8 }
hh3cStackPortConfigActivate OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
set(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"After connecting the physical interfaces between two devices and
binding them to the correct IRF ports, you must
activate the settings on the IRF ports. This operation merges the two
devices into one IRF fabric. The system activates the IRF port
settings automatically in the following situations:
1. The configuration file that the device starts with contains
IRF port bindings.
2. You are binding physical interfaces to an IRF port after an IRF fabric
is formed.
none: If the user sets this object to none, this object will return
a success without performing any operation.
set: Activates the settings on the IRF ports.
After the settings is activated, this object will return to
none at the next reading."
DEFVAL { none }
::= { hh3cStackGlobalConfig 9 }
-- Device Level Configuration
hh3cStackDeviceConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cStackDeviceConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects to manage device information in a stack."
::= { hh3cStack 2 }
hh3cStackDeviceConfigEntry OBJECT-TYPE
SYNTAX Hh3cStackDeviceConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects to manage device information in a stack."
INDEX
{
entPhysicalIndex
}
::= { hh3cStackDeviceConfigTable 1 }
Hh3cStackDeviceConfigEntry ::= SEQUENCE
{
hh3cStackMemberID Integer32,
hh3cStackConfigMemberID Integer32,
hh3cStackPriority Integer32,
hh3cStackPortNum Integer32,
hh3cStackPortMaxNum Integer32
}
hh3cStackMemberID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The member ID of the device in a stack."
::= { hh3cStackDeviceConfigEntry 1 }
hh3cStackConfigMemberID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured member ID of the device. The valid value ranges from
1 to the value in hh3cStackMaxMember. The configured member ID will
take effect at a reboot if it is unique within the stack."
::= { hh3cStackDeviceConfigEntry 2 }
hh3cStackPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The priority of a device in the stack. The valid value ranges from
1 to the value in hh3cStackMaxConfigPriority."
::= { hh3cStackDeviceConfigEntry 3 }
hh3cStackPortNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of stack ports enabled on a device."
::= { hh3cStackDeviceConfigEntry 4 }
hh3cStackPortMaxNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of stack ports on a device."
::= { hh3cStackDeviceConfigEntry 5 }
-- Board Level Configuration
hh3cStackBoardConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cStackBoardConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects to manage MPU information for a stack."
::= { hh3cStack 3 }
hh3cStackBoardConfigEntry OBJECT-TYPE
SYNTAX Hh3cStackBoardConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects to manage MPU information for a stack."
INDEX
{
entPhysicalIndex
}
::= { hh3cStackBoardConfigTable 1 }
Hh3cStackBoardConfigEntry ::= SEQUENCE
{
hh3cStackBoardRole INTEGER,
hh3cStackBoardBelongtoMember Integer32
}
hh3cStackBoardRole OBJECT-TYPE
SYNTAX INTEGER
{
slave(1),
master(2),
loading(3),
other(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The role of the MPU in a stack.
slave: Standby MPU
master: Master MPU
loading: Standby MPU is loading the software image from the master.
other: other"
::= { hh3cStackBoardConfigEntry 1 }
hh3cStackBoardBelongtoMember OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Member ID of the device that holds the current board."
::= { hh3cStackBoardConfigEntry 2 }
-- stack port Information
hh3cStackPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cStackPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects to manage stack port information
for IRF stacked devices."
::= { hh3cStack 4 }
hh3cStackPortInfoEntry OBJECT-TYPE
SYNTAX Hh3cStackPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects to manage stack port information
for IRF stacked devices."
INDEX
{
hh3cStackMemberID,
hh3cStackPortIndex
}
::= { hh3cStackPortInfoTable 1 }
Hh3cStackPortInfoEntry ::= SEQUENCE
{
hh3cStackPortIndex Integer32,
hh3cStackPortEnable INTEGER,
hh3cStackPortStatus INTEGER,
hh3cStackNeighbor Integer32,
hh3cStackPortForwardingPath OCTET STRING
}
hh3cStackPortIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of a stack port of the device."
::= { hh3cStackPortInfoEntry 1 }
hh3cStackPortEnable OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
enabled(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a stack port of the device. If no physical
interfaces are added to the stack port, its status is disabled.
If the stack port has physical interfaces, its status is enabled.
disabled: The stack port is disabled.
enabled: The stack port is enabled."
::= { hh3cStackPortInfoEntry 2 }
hh3cStackPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2),
silent(3),
disabled(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link status of a stack port on the device.
up: A physical link is present on the stack port.
down: No physical link is present on the stack port.
silent: The link state of the stack port is up,
but the port can't transmit or receive traffic.
disabled: The stack port doesn't contain physical links."
::= { hh3cStackPortInfoEntry 3 }
hh3cStackNeighbor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The member ID of the stack port's neighbor. 0 means no
neighbor exists."
::= { hh3cStackPortInfoEntry 4 }
hh3cStackPortForwardingPath OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..511))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"List of egress member IDs on a stack port.
Each member device uses the egress member ID lists to choose the outgoing
stack port for known unicast frames to be sent out of other member devices.
The egress member ID lists are comma separated.
A zero-length string means no egress members exist.
For example:
In a ring stack of 1-2-3-4-5-7-1,
if hh3cStackPortForwardingPath.1.1 returns '7,5,4',
IRF-port 1/1 will be the outgoing port for frames to reach members 7, 5,
and 4 from member 1."
::= { hh3cStackPortInfoEntry 5 }
-- Physical interface Information
hh3cStackPhyPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cStackPhyPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects to manage information about physical
interfaces that can be used for IRF stacking."
::= { hh3cStack 5 }
hh3cStackPhyPortInfoEntry OBJECT-TYPE
SYNTAX Hh3cStackPhyPortInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects to manage information about physical
interfaces that can be used for IRF stacking."
INDEX
{
entPhysicalIndex
}
::= { hh3cStackPhyPortInfoTable 1 }
Hh3cStackPhyPortInfoEntry ::= SEQUENCE
{
hh3cStackBelongtoPort Integer32
}
hh3cStackBelongtoPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The index of the stack port to which the physical interface is added.
0 means the physical interface is not added to any stack port.
The value will take effect when IRF is enabled on the device."
::= { hh3cStackPhyPortInfoEntry 1 }
--
-- Notification definitions
--
-- =================================================================
-- Traps are defined below.
hh3cStackTrap OBJECT IDENTIFIER ::= { hh3cStack 6 }
hh3cStackTrapOjbects OBJECT IDENTIFIER ::= { hh3cStackTrap 0 }
-- All trap definitions should be placed under this object.
hh3cStackPortLinkStatusChange NOTIFICATION-TYPE
OBJECTS
{
hh3cStackMemberID,
hh3cStackPortIndex,
hh3cStackPortStatus
}
STATUS current
DESCRIPTION
"The hh3cStackPortLinkStatusChange trap indicates that the link status
of the stack port has changed."
::= { hh3cStackTrapOjbects 1 }
hh3cStackTopologyChange NOTIFICATION-TYPE
OBJECTS
{
hh3cStackTopology
}
STATUS current
DESCRIPTION
"The hh3cStackTopologyChange trap indicates that the topology type of
the IRF stack has changed."
::= { hh3cStackTrapOjbects 2 }
hh3cStackMadBfdChangeNormal NOTIFICATION-TYPE
OBJECTS
{
ifIndex,
ifDescr
}
STATUS current
DESCRIPTION
"The hh3cStackMadBfdChangeNormal trap indicates that the BFD MAD function
changed to the normal state."
::= { hh3cStackTrapOjbects 3 }
hh3cStackMadBfdChangeFailure NOTIFICATION-TYPE
OBJECTS
{
ifIndex,
ifDescr
}
STATUS current
DESCRIPTION
"The hh3cStackMadBfdChangeFailure trap indicates that the BFD MAD function
changed to the failure state."
::= { hh3cStackTrapOjbects 4 }
hh3cStackMadLacpChangeNormal NOTIFICATION-TYPE
OBJECTS
{
ifIndex,
ifDescr
}
STATUS current
DESCRIPTION
"The hh3cStackMadLacpChangeNormal trap indicates that the LACP MAD function
changed to the normal state."
::= { hh3cStackTrapOjbects 5 }
hh3cStackMadLacpChangeFailure NOTIFICATION-TYPE
OBJECTS
{
ifIndex,
ifDescr
}
STATUS current
DESCRIPTION
"The hh3cStackMadLacpChangeFailure trap indicates that the LACP MAD function
changed to the failure state."
::= { hh3cStackTrapOjbects 6 }
hh3cStackPhysicalIntfLinkUp NOTIFICATION-TYPE
OBJECTS
{
hh3cStackMemberID,
hh3cStackPortIndex,
hh3cStackPhysicalIntfName
}
STATUS current
DESCRIPTION
"The hh3cStackPhysicalIntfLinkUp trap indicates that the status
of the stack physical interface has changed to the up state."
::= { hh3cStackTrapOjbects 7 }
hh3cStackPhysicalIntfLinkDown NOTIFICATION-TYPE
OBJECTS
{
hh3cStackMemberID,
hh3cStackPortIndex,
hh3cStackPhysicalIntfName
}
STATUS current
DESCRIPTION
"The hh3cStackPhysicalIntfLinkDown trap indicates that the status
of the stack physical interface has changed to the down state."
::= { hh3cStackTrapOjbects 8 }
hh3cStackPhysicalIntfRxTimeout NOTIFICATION-TYPE
OBJECTS
{
hh3cStackMemberID,
hh3cStackPortIndex,
hh3cStackPhysicalIntfName
}
STATUS current
DESCRIPTION
"The hh3cStackPhysicalIntfRxTimeout trap indicates that the timer for the stack
physical interface to receive packets has timed out."
::= { hh3cStackTrapOjbects 9 }
hh3cStackTrapObjectDefinitions OBJECT IDENTIFIER ::= { hh3cStackTrap 1 }
-- All objects used for TRAP only are defined here.
hh3cStackPhysicalIntfName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..255))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The textual name of the stack physical interface."
::= { hh3cStackTrapObjectDefinitions 1 }
END