mibs/MIBS/comware/HH3C-TE-TUNNEL-MIB
2023-12-05 12:25:34 +01:00

544 lines
17 KiB
Plaintext

-- =================================================================
-- Copyright (c) 2004-2011 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: This MIB define objects for MPLS Te Tunnel.
-- Reference:
-- Version: V1.0
-- History:
-- V1.0 2011-03-24 Created by fengnina 04924.
-- ==================================================================
HH3C-TE-TUNNEL-MIB DEFINITIONS ::= BEGIN
IMPORTS
hh3cCommon
FROM HH3C-OID-MIB
MplsTunnelIndex, MplsTunnelInstanceIndex, MplsExtendedTunnelId, MplsLabel
FROM MPLS-TC-STD-MIB
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
RowPointer
FROM SNMPv2-TC;
hh3cTeTunnel MODULE-IDENTITY
LAST-UPDATED "201103240948Z" -- March 24, 2011 at 09:48 GMT
ORGANIZATION
"New H3C Tech. Co., Ltd."
CONTACT-INFO
"Platform Team New H3C Tech. Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip:100085"
DESCRIPTION
"This MIB contains managed object definitions for the
Multiprotocol Label Switching (MPLS) Te Tunnel."
::= { hh3cCommon 115 }
--
-- Node definitions
--
hh3cTeTunnelScalars OBJECT IDENTIFIER ::= { hh3cTeTunnel 1 }
hh3cTeTunnelMaxTunnelIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max value of tunnel id is permitted configure on the device."
::= { hh3cTeTunnelScalars 1 }
hh3cTeTunnelObjects OBJECT IDENTIFIER ::= { hh3cTeTunnel 2 }
hh3cTeTunnelStaticCrlspTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cTeTunnelStaticCrlspEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information for static-crlsp, and through this
to get detail information about this static-crlsp. Only support
transit LSR and egress LSR."
::= { hh3cTeTunnelObjects 1 }
hh3cTeTunnelStaticCrlspEntry OBJECT-TYPE
SYNTAX Hh3cTeTunnelStaticCrlspEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry in this table describes static-crlsp information."
INDEX { hh3cTeTunnelStaticCrlspInLabel }
::= { hh3cTeTunnelStaticCrlspTable 1 }
Hh3cTeTunnelStaticCrlspEntry ::=
SEQUENCE {
hh3cTeTunnelStaticCrlspInLabel
MplsLabel,
hh3cTeTunnelStaticCrlspName
OCTET STRING,
hh3cTeTunnelStaticCrlspStatus
INTEGER,
hh3cTeTunnelStaticCrlspRole
INTEGER,
hh3cTeTunnelStaticCrlspXCPointer
RowPointer
}
hh3cTeTunnelStaticCrlspInLabel OBJECT-TYPE
SYNTAX MplsLabel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is unique label value that manualy assigned. Uniquely
identifies a static-crlsp. Managers should use this to obtain
detail static-crlsp information."
::= { hh3cTeTunnelStaticCrlspEntry 1 }
hh3cTeTunnelStaticCrlspName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique name assigned to the static-crlsp."
::= { hh3cTeTunnelStaticCrlspEntry 2 }
hh3cTeTunnelStaticCrlspStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the actual status of this static-crlsp,
The value must be up when the static-crlsp status is up and
the value must be down when the static-crlsp status is down."
::= { hh3cTeTunnelStaticCrlspEntry 3 }
hh3cTeTunnelStaticCrlspRole OBJECT-TYPE
SYNTAX INTEGER
{
transit(1),
tail(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicate the role of this static-crlsp. This value must
be transit at transit point of the tunnel, and tail at
terminating point of the tunnel."
::= { hh3cTeTunnelStaticCrlspEntry 4 }
hh3cTeTunnelStaticCrlspXCPointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This pointer unique identify a row of mplsXCTable.
This value should be zeroDotZero when the static-crlsp
is down. The mplsXCTable identifies the segments that
compose this tunnel, their characteristics, and relationships
to each other."
::= { hh3cTeTunnelStaticCrlspEntry 5 }
hh3cTeTunnelCoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cTeTunnelCoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information for Co-routed reverse crlsp and
infomation of Co-routed bidirectional Tunnel Interface.
If hh3cCorouteTunnelLspInstance is zero, to obtain infomation of
Co-routed bidirectional Tunnel Interface, otherwise to obtain
Co-routed reverse crlsp infomation."
::= { hh3cTeTunnelObjects 2 }
hh3cTeTunnelCoEntry OBJECT-TYPE
SYNTAX Hh3cTeTunnelCoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry in this table describes Co-routed infomation of
bidirectional Tunnel Interface and reserver lsp information."
INDEX { hh3cTeTunnelCoIndex, hh3cTeTunnelCoLspInstance, hh3cTeTunnelCoIngressLSRId, hh3cTeTunnelCoEgressLSRId }
::= { hh3cTeTunnelCoTable 1 }
Hh3cTeTunnelCoEntry ::=
SEQUENCE {
hh3cTeTunnelCoIndex
MplsTunnelIndex,
hh3cTeTunnelCoLspInstance
MplsTunnelInstanceIndex,
hh3cTeTunnelCoIngressLSRId
MplsExtendedTunnelId,
hh3cTeTunnelCoEgressLSRId
MplsExtendedTunnelId,
hh3cTeTunnelCoBiMode
INTEGER,
hh3cTeTunnelCoReverseLspInstance
MplsTunnelInstanceIndex,
hh3cTeTunnelCoReverseLspXCPointer
RowPointer
}
hh3cTeTunnelCoIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies a set of tunnel instances between a pair
of ingress and egress LSRs that specified at originating point.
This value should be equal to the value signaled in the
Tunnel Id of the Session object."
::= { hh3cTeTunnelCoEntry 1 }
hh3cTeTunnelCoLspInstance OBJECT-TYPE
SYNTAX MplsTunnelInstanceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"When obtain infomation of Co-routed bidirectional Tunnel Interface,
this vlaue should be zero. And this value must be LspID to obtain
reverse crlsp information. Values greater than 0, but less than or
equal to 65535, should be useless."
::= { hh3cTeTunnelCoEntry 2 }
hh3cTeTunnelCoIngressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identity the ingress LSR associated with this tunnel instance.
This vlaue is equal to the LsrID of originating endpoint."
::= { hh3cTeTunnelCoEntry 3 }
hh3cTeTunnelCoEgressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identity of the egress LSR associated with this tunnel instance.
This vlaue is equal to the LsrID of terminating point."
::= { hh3cTeTunnelCoEntry 4 }
hh3cTeTunnelCoBiMode OBJECT-TYPE
SYNTAX INTEGER
{
coroutedActive(1),
coroutedPassive(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This vlaue indicated the bidirection mode of tunnel interface.
The valuemust be coroutedActive at the originating point of the
tunnel and coroutedPassive at the terminating point."
::= { hh3cTeTunnelCoEntry 5 }
hh3cTeTunnelCoReverseLspInstance OBJECT-TYPE
SYNTAX MplsTunnelInstanceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicated the reverse lsp instance, and
should be equal to obverse lsp instance."
::= { hh3cTeTunnelCoEntry 6 }
hh3cTeTunnelCoReverseLspXCPointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This pointer unique index to mplsXCTable of the reverse lsp.
The mplsXCTable identifies the segments that compose this tunnel,
their characteristics, and relationships to each other. A
value of zeroDotZero indicate that there is no crlsp assigned
to this."
::= { hh3cTeTunnelCoEntry 7 }
hh3cTeTunnelPsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cTeTunnelPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines some objects for managers to obtain
TE tunnel Protection Switching group current status information."
::= { hh3cTeTunnelObjects 3 }
hh3cTeTunnelPsEntry OBJECT-TYPE
SYNTAX Hh3cTeTunnelPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry in this table describes TE tunnel Protection
Switching group infromation."
INDEX { hh3cTeTunnelPsIndex, hh3cTeTunnelPsIngressLSRId, hh3cTeTunnelPsEgressLSRId }
::= { hh3cTeTunnelPsTable 1 }
Hh3cTeTunnelPsEntry ::=
SEQUENCE {
hh3cTeTunnelPsIndex
MplsTunnelIndex,
hh3cTeTunnelPsIngressLSRId
MplsExtendedTunnelId,
hh3cTeTunnelPsEgressLSRId
MplsExtendedTunnelId,
hh3cTeTunnelPsProtectIndex
MplsTunnelIndex,
hh3cTeTunnelPsProtectIngressLSRId
MplsExtendedTunnelId,
hh3cTeTunnelPsProtectEgressLSRId
MplsExtendedTunnelId,
hh3cTeTunnelPsProtectType
INTEGER,
hh3cTeTunnelPsRevertiveMode
INTEGER,
hh3cTeTunnelPsWtrTime
Unsigned32,
hh3cTeTunnelPsHoldOffTime
Unsigned32,
hh3cTeTunnelPsSwitchMode
INTEGER,
hh3cTeTunnelPsWorkPathStatus
INTEGER,
hh3cTeTunnelPsProtectPathStatus
INTEGER,
hh3cTeTunnelPsSwitchResult
INTEGER
}
hh3cTeTunnelPsIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies a TE tunnel Protection Switching group
instance. This value must be equal to the tunnel id of work
tunnel instance."
::= { hh3cTeTunnelPsEntry 1 }
hh3cTeTunnelPsIngressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identity the ingress LSR associated with work tunnel instance."
::= { hh3cTeTunnelPsEntry 2 }
hh3cTeTunnelPsEgressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identity of the egress LSR associated with work tunnel instance."
::= { hh3cTeTunnelPsEntry 3 }
hh3cTeTunnelPsProtectIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Uniquely identifies a TE tunnel Protection Switching
group instance. This value must be equal to the tunnel
id of TE tunnel Protection Switching group instance."
::= { hh3cTeTunnelPsEntry 4 }
hh3cTeTunnelPsProtectIngressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identity the ingress LSR associated with TE tunnel
Protection Switching group instance."
::= { hh3cTeTunnelPsEntry 5 }
hh3cTeTunnelPsProtectEgressLSRId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identity of the egress LSR associated with TE tunnel
Protection Switching group instance."
::= { hh3cTeTunnelPsEntry 6 }
hh3cTeTunnelPsProtectType OBJECT-TYPE
SYNTAX INTEGER
{
oneToOne(1),
onePlusOne(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicated TE tunnel Protection Switching group
type. The default value is oneToOne."
DEFVAL { oneToOne }
::= { hh3cTeTunnelPsEntry 7 }
hh3cTeTunnelPsRevertiveMode OBJECT-TYPE
SYNTAX INTEGER
{
revertive(1),
noRevertive(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicated protect switch mode. The value must be
revertive or nonRevertive, default value is revertive.
"
DEFVAL { revertive }
::= { hh3cTeTunnelPsEntry 8 }
hh3cTeTunnelPsWtrTime OBJECT-TYPE
SYNTAX Unsigned32 (0..60)
UNITS "30 seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cycle time that switch to protect tunnel."
DEFVAL { 24 }
::= { hh3cTeTunnelPsEntry 9 }
hh3cTeTunnelPsHoldOffTime OBJECT-TYPE
SYNTAX Unsigned32 (0..20)
UNITS "500ms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is switchback delay time. When detected the work path
fault, switch to protect path after this time."
DEFVAL { 0 }
::= { hh3cTeTunnelPsEntry 10 }
hh3cTeTunnelPsSwitchMode OBJECT-TYPE
SYNTAX INTEGER
{
uniDirectional(1),
biDirectional(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicated TE tunnel Protection Switching
group switch mode."
DEFVAL { uniDirectional }
::= { hh3cTeTunnelPsEntry 11 }
hh3cTeTunnelPsWorkPathStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
noDefect(2),
inDefect(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates work path status. none, noDefect, inDefect
will be used."
::= { hh3cTeTunnelPsEntry 12 }
hh3cTeTunnelPsProtectPathStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
noDefect(2),
inDefect(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates protect path status. none, noDefect,
inDefect(3) will be used."
::= { hh3cTeTunnelPsEntry 13 }
hh3cTeTunnelPsSwitchResult OBJECT-TYPE
SYNTAX INTEGER
{
workPath(1),
protectPath(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicated current using path is work path or protect
path."
::= { hh3cTeTunnelPsEntry 14 }
hh3cTeTunnelNotifications OBJECT IDENTIFIER ::= { hh3cTeTunnel 3 }
hh3cTeTunnelNotificationsPrefix OBJECT IDENTIFIER ::= { hh3cTeTunnelNotifications 0 }
hh3cTeTunnelPsSwitchWtoP NOTIFICATION-TYPE
OBJECTS { hh3cTeTunnelPsWorkPathStatus, hh3cTeTunnelPsProtectPathStatus }
STATUS current
DESCRIPTION
"This notification is generated when protect workgroup switch from
work tunnel to protect tunnel."
::= { hh3cTeTunnelNotificationsPrefix 1 }
hh3cTeTunnelPsSwitchPtoW NOTIFICATION-TYPE
OBJECTS { hh3cTeTunnelPsWorkPathStatus, hh3cTeTunnelPsProtectPathStatus }
STATUS current
DESCRIPTION
"This notification is generated when protect workgroup switch from
protect tunnel to work tunnel."
::= { hh3cTeTunnelNotificationsPrefix 2 }
hh3cTeTunnelConformance OBJECT IDENTIFIER ::= { hh3cTeTunnel 4 }
hh3cTeTunnelCompliances OBJECT IDENTIFIER ::= { hh3cTeTunnelConformance 1 }
hh3cTeTunnelCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP."
MODULE -- this module
MANDATORY-GROUPS { hh3cTeTunnelNotificationsGroup, hh3cTeTunnelScalarsGroup, hh3cTeTunnelStaticCrlspGroup, hh3cTeTunnelCorouteGroup, hh3cTeTunnelPsGroup
}
::= { hh3cTeTunnelCompliances 1 }
hh3cTeTunnelGroups OBJECT IDENTIFIER ::= { hh3cTeTunnelConformance 2 }
hh3cTeTunnelNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { hh3cTeTunnelPsSwitchPtoW, hh3cTeTunnelPsSwitchWtoP }
STATUS current
DESCRIPTION
"This group contains MPLS Te Tunnel traps."
::= { hh3cTeTunnelGroups 1 }
hh3cTeTunnelScalarsGroup OBJECT-GROUP
OBJECTS { hh3cTeTunnelMaxTunnelIndex }
STATUS current
DESCRIPTION
"Scalar object needed to implement MPLS te tunnels."
::= { hh3cTeTunnelGroups 2 }
hh3cTeTunnelStaticCrlspGroup OBJECT-GROUP
OBJECTS { hh3cTeTunnelStaticCrlspName, hh3cTeTunnelStaticCrlspStatus, hh3cTeTunnelStaticCrlspRole, hh3cTeTunnelStaticCrlspXCPointer }
STATUS current
DESCRIPTION
"Objects for quering static-crlsp information."
::= { hh3cTeTunnelGroups 3 }
hh3cTeTunnelCorouteGroup OBJECT-GROUP
OBJECTS { hh3cTeTunnelCoBiMode, hh3cTeTunnelCoReverseLspInstance, hh3cTeTunnelCoReverseLspXCPointer }
STATUS current
DESCRIPTION
"Objects for quering Co-routed reverse crlsp information."
::= { hh3cTeTunnelGroups 4 }
hh3cTeTunnelPsGroup OBJECT-GROUP
OBJECTS { hh3cTeTunnelPsProtectIndex, hh3cTeTunnelPsProtectIngressLSRId, hh3cTeTunnelPsProtectEgressLSRId, hh3cTeTunnelPsProtectType, hh3cTeTunnelPsRevertiveMode,
hh3cTeTunnelPsWtrTime, hh3cTeTunnelPsHoldOffTime, hh3cTeTunnelPsSwitchMode, hh3cTeTunnelPsWorkPathStatus, hh3cTeTunnelPsProtectPathStatus,
hh3cTeTunnelPsSwitchResult }
STATUS current
DESCRIPTION
"Objects for quering protect workgroup information."
::= { hh3cTeTunnelGroups 5 }
END