--/********************* (c) 2010-2019 CyberPower System ***************************/
|
|
--
|
|
-- PROJECT: SNMP MIB FILE CONSTRUCTED
|
|
--
|
|
-- Version : 2.9
|
|
--
|
|
-- File Name: CPSMIB2019.mib
|
|
--
|
|
-- CREATION DATE : 10/23/2019
|
|
--
|
|
-- AUTHOR : Kevin
|
|
--
|
|
--//////////////////////////////////////////////////////////////////////////////
|
|
--
|
|
-- DESCRIPTION : CPS Management Information Base(MIB)
|
|
--
|
|
--//////////////////////////////////////////////////////////////////////////////
|
|
--
|
|
--
|
|
--/****************************************************************************/
|
|
-- CPSMIB { iso org(3) dod(6) internet(1) private(4)
|
|
-- enterprises(1) cps(3808) }
|
|
|
|
CPS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises, Gauge, TimeTicks, IpAddress FROM RFC1155-SMI
|
|
DisplayString FROM RFC1213-MIB
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215;
|
|
|
|
|
|
cps OBJECT IDENTIFIER ::= { enterprises 3808 }
|
|
|
|
products OBJECT IDENTIFIER ::= { cps 1 }
|
|
cpsmgmt OBJECT IDENTIFIER ::= { cps 2 }
|
|
|
|
hardware OBJECT IDENTIFIER ::= { products 1 }
|
|
|
|
|
|
mconfig OBJECT IDENTIFIER ::= { cpsmgmt 1 }
|
|
mtrapinfo OBJECT IDENTIFIER ::= { cpsmgmt 2 }
|
|
mcontrol OBJECT IDENTIFIER ::= { cpsmgmt 3 }
|
|
|
|
ups OBJECT IDENTIFIER ::= { hardware 1 }
|
|
eswitch OBJECT IDENTIFIER ::= { hardware 2 }
|
|
ePDU OBJECT IDENTIFIER ::= { hardware 3 }
|
|
environmentSensor OBJECT IDENTIFIER ::= { hardware 4 }
|
|
ats OBJECT IDENTIFIER ::= { hardware 5 }
|
|
ePDU2 OBJECT IDENTIFIER ::= { hardware 6 }
|
|
battmgr OBJECT IDENTIFIER ::= { hardware 7 }
|
|
|
|
mconfigClock OBJECT IDENTIFIER ::= { mconfig 5 }
|
|
|
|
|
|
upsIdent OBJECT IDENTIFIER ::= { ups 1 }
|
|
upsBattery OBJECT IDENTIFIER ::= { ups 2 }
|
|
upsInput OBJECT IDENTIFIER ::= { ups 3 }
|
|
upsOutput OBJECT IDENTIFIER ::= { ups 4 }
|
|
upsConfig OBJECT IDENTIFIER ::= { ups 5 }
|
|
upsControl OBJECT IDENTIFIER ::= { ups 6 }
|
|
upsTest OBJECT IDENTIFIER ::= { ups 7 }
|
|
upsOutlet OBJECT IDENTIFIER ::= { ups 8 }
|
|
upsPhase OBJECT IDENTIFIER ::= { ups 9 }
|
|
upsSystem OBJECT IDENTIFIER ::= { ups 10 }
|
|
|
|
upsBaseIdent OBJECT IDENTIFIER ::= { upsIdent 1 }
|
|
upsAdvanceIdent OBJECT IDENTIFIER ::= { upsIdent 2 }
|
|
|
|
upsBaseBattery OBJECT IDENTIFIER ::= { upsBattery 1 }
|
|
upsAdvanceBattery OBJECT IDENTIFIER ::= { upsBattery 2 }
|
|
|
|
upsBaseInput OBJECT IDENTIFIER ::= { upsInput 1 }
|
|
upsAdvanceInput OBJECT IDENTIFIER ::= { upsInput 2 }
|
|
|
|
upsBaseOutput OBJECT IDENTIFIER ::= { upsOutput 1 }
|
|
upsAdvanceOutput OBJECT IDENTIFIER ::= { upsOutput 2 }
|
|
|
|
upsBaseConfig OBJECT IDENTIFIER ::= { upsConfig 1 }
|
|
upsAdvanceConfig OBJECT IDENTIFIER ::= { upsConfig 2 }
|
|
|
|
upsBaseControl OBJECT IDENTIFIER ::= { upsControl 1 }
|
|
upsAdvanceControl OBJECT IDENTIFIER ::= { upsControl 2 }
|
|
|
|
upsBaseTest OBJECT IDENTIFIER ::= { upsTest 1 }
|
|
upsAdvanceTest OBJECT IDENTIFIER ::= { upsTest 2 }
|
|
|
|
upsBankOutletControl OBJECT IDENTIFIER ::= { upsOutlet 1 }
|
|
|
|
upsPhaseInput OBJECT IDENTIFIER ::= { upsPhase 1 }
|
|
upsPhaseOutput OBJECT IDENTIFIER ::= { upsPhase 2 }
|
|
upsPhaseBypass OBJECT IDENTIFIER ::= { upsPhase 3 }
|
|
|
|
eSwitchIdent OBJECT IDENTIFIER ::= { eswitch 1 }
|
|
eSwitchBase OBJECT IDENTIFIER ::= { eswitch 2 }
|
|
|
|
|
|
ePDUIdent OBJECT IDENTIFIER ::= { ePDU 1 }
|
|
ePDULoad OBJECT IDENTIFIER ::= { ePDU 2 }
|
|
ePDUOutlet OBJECT IDENTIFIER ::= { ePDU 3 }
|
|
ePDUPowerSupply OBJECT IDENTIFIER ::= { ePDU 4 }
|
|
ePDUStatus OBJECT IDENTIFIER ::= { ePDU 5 }
|
|
|
|
ePDULoadDevice OBJECT IDENTIFIER ::= { ePDULoad 1 }
|
|
ePDULoadPhaseConfig OBJECT IDENTIFIER ::= { ePDULoad 2 }
|
|
ePDULoadStatus OBJECT IDENTIFIER ::= { ePDULoad 3 }
|
|
ePDULoadBankConfig OBJECT IDENTIFIER ::= { ePDULoad 4 }
|
|
|
|
ePDUOutletDevice OBJECT IDENTIFIER ::= { ePDUOutlet 1 }
|
|
ePDUOutletPhase OBJECT IDENTIFIER ::= { ePDUOutlet 2 }
|
|
ePDUOutletControl OBJECT IDENTIFIER ::= { ePDUOutlet 3 }
|
|
ePDUOutletConfig OBJECT IDENTIFIER ::= { ePDUOutlet 4 }
|
|
ePDUOutletStatus OBJECT IDENTIFIER ::= { ePDUOutlet 5 }
|
|
ePDUOutletBank OBJECT IDENTIFIER ::= { ePDUOutlet 6 }
|
|
|
|
ePDUPowerSupplyDevice OBJECT IDENTIFIER ::= { ePDUPowerSupply 1 }
|
|
|
|
envirIdent OBJECT IDENTIFIER ::= { environmentSensor 1 }
|
|
envirTemp OBJECT IDENTIFIER ::= { environmentSensor 2 }
|
|
envirHumid OBJECT IDENTIFIER ::= { environmentSensor 3 }
|
|
envirContact OBJECT IDENTIFIER ::= { environmentSensor 4 }
|
|
|
|
atsIdent OBJECT IDENTIFIER ::= { ats 1 }
|
|
atsStatus OBJECT IDENTIFIER ::= { ats 2 }
|
|
atsConfig OBJECT IDENTIFIER ::= { ats 3 }
|
|
atsControl OBJECT IDENTIFIER ::= { ats 4 }
|
|
atsLoad OBJECT IDENTIFIER ::= { ats 5 }
|
|
atsOutlet OBJECT IDENTIFIER ::= { ats 6 }
|
|
|
|
atsStatusDevice OBJECT IDENTIFIER ::= { atsStatus 1 }
|
|
atsStatusInput OBJECT IDENTIFIER ::= { atsStatus 2 }
|
|
|
|
atsLoadDevice OBJECT IDENTIFIER ::= { atsLoad 1 }
|
|
atsLoadStatus OBJECT IDENTIFIER ::= { atsLoad 2 }
|
|
atsLoadConfig OBJECT IDENTIFIER ::= { atsLoad 3 }
|
|
|
|
atsOutletDevice OBJECT IDENTIFIER ::= { atsOutlet 1 }
|
|
|
|
-- ePDU2 1 as Role OID.
|
|
ePDU2Ident OBJECT IDENTIFIER ::= { ePDU2 2 }
|
|
ePDU2Device OBJECT IDENTIFIER ::= { ePDU2 3 }
|
|
ePDU2Phase OBJECT IDENTIFIER ::= { ePDU2 4 }
|
|
ePDU2Bank OBJECT IDENTIFIER ::= { ePDU2 5 }
|
|
ePDU2Outlet OBJECT IDENTIFIER ::= { ePDU2 6 }
|
|
|
|
ePDU2OutletSwitched OBJECT IDENTIFIER ::= { ePDU2Outlet 1 }
|
|
ePDU2OutletMetered OBJECT IDENTIFIER ::= { ePDU2Outlet 2 }
|
|
|
|
ePDU2Sensor OBJECT IDENTIFIER ::= { ePDU2 7 }
|
|
ePDU2Group OBJECT IDENTIFIER ::= { ePDU2 8 }
|
|
|
|
bmIdent OBJECT IDENTIFIER ::= { battmgr 1 }
|
|
bmProperty OBJECT IDENTIFIER ::= { battmgr 2 }
|
|
bmConfig OBJECT IDENTIFIER ::= { battmgr 3 }
|
|
bmControl OBJECT IDENTIFIER ::= { battmgr 4 }
|
|
bmProbes OBJECT IDENTIFIER ::= { battmgr 5 }
|
|
bmFuncRes OBJECT IDENTIFIER ::= { battmgr 6 }
|
|
bmFuncEqual OBJECT IDENTIFIER ::= { battmgr 7 }
|
|
|
|
bmFuncResMeasure OBJECT IDENTIFIER ::= { bmFuncRes 1 }
|
|
|
|
-- object types
|
|
-- the cpsmgmt group
|
|
-- the mconfig group
|
|
mconfigNumTrapAccepters OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of receivers to send traps to."
|
|
::= { mconfig 1 }
|
|
|
|
mconfigTrapAccepterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MconfigTrapAccepterEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of receivers to send traps to. The numbers of
|
|
entries are given by the value of mconfigNumTrapAccepters."
|
|
::= { mconfig 2 }
|
|
|
|
mconfigTrapAccepterEntry OBJECT-TYPE
|
|
SYNTAX MconfigTrapAccepterEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The receivers to send traps to."
|
|
INDEX { trapIndex }
|
|
::= { mconfigTrapAccepterTable 1 }
|
|
|
|
MconfigTrapAccepterEntry ::=
|
|
SEQUENCE {
|
|
trapIndex
|
|
INTEGER,
|
|
accepterAddr
|
|
IpAddress,
|
|
communityString
|
|
DisplayString,
|
|
severityDegree
|
|
INTEGER,
|
|
accepterActive
|
|
INTEGER
|
|
}
|
|
|
|
trapIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The trap receiver entry index."
|
|
::= { mconfigTrapAccepterEntry 1 }
|
|
|
|
accepterAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The trap receiver IP address."
|
|
::= { mconfigTrapAccepterEntry 2 }
|
|
|
|
communityString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The trap receiver community name."
|
|
::= { mconfigTrapAccepterEntry 3 }
|
|
|
|
severityDegree OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
information(1),
|
|
warning(2),
|
|
severe(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The trap receiver severity level. Traps are marked in severity level
|
|
as informational(1), warning(2), severe(3). Only send the traps of
|
|
equal or greater severity than this value to the receiver."
|
|
::= { mconfigTrapAccepterEntry 4 }
|
|
|
|
accepterActive OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A receiver will accept traps if yes, and none if no."
|
|
::= { mconfigTrapAccepterEntry 5 }
|
|
|
|
mconfigDHCPEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system will automatically obtain its IP from a DHCP server if yes,
|
|
and none if no."
|
|
::= { mconfig 3 }
|
|
|
|
mconfigMyAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system IP address."
|
|
::= { mconfig 4 }
|
|
|
|
|
|
mconfigClockDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current date in the mm/dd/yyyy format. Example: 01/01/2000."
|
|
::= { mconfigClock 1 }
|
|
|
|
mconfigClockTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current time in the hh:mm:ss 24H format."
|
|
::= { mconfigClock 2 }
|
|
|
|
|
|
|
|
-- The mtrapinfo group
|
|
-- These OIDs allows CPS traps to be sent with additional arguments
|
|
-- which may not be defined in the CPS MIB.
|
|
mtrapinfoInteger OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allow CPS traps with an integer argument for providing detail
|
|
information. Not being defined in the MIB, only reply 0."
|
|
::= { mtrapinfo 1 }
|
|
|
|
mtrapinfoIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allow CPS traps with an IP address argument for providing detail
|
|
information. Not being defined in the MIB, only reply 0.0.0.0."
|
|
::= { mtrapinfo 2 }
|
|
|
|
mtrapinfoString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allow CPS traps with an octet string argument for providing detail
|
|
information. Not being defined in the MIB, only reply a NULL string."
|
|
::= { mtrapinfo 3 }
|
|
|
|
mtrapinfoGauge OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allow CPS traps with an Gauge argument for providing detail
|
|
information. Not being defined in the MIB, only reply 0."
|
|
::= { mtrapinfo 4 }
|
|
|
|
mtrapinfoTimeTicks OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allow CPS traps with an TimeTicks argument for providing detail
|
|
information. Not being defined in the MIB, only reply 0."
|
|
::= { mtrapinfo 5 }
|
|
|
|
mtrapinfoBmEventId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allow CPS traps with an integer argument for providing detail
|
|
information about Battery Manager specific event identifier.
|
|
Not being defined in the MIB, only reply 0.
|
|
|
|
Known Specific Event ID: Battery Manager
|
|
0 - not used
|
|
1 - Alarm: The battery manager system fault.
|
|
2 - Info: Device configuration changed.
|
|
3 - Alarm: Probe configuration mismatched.
|
|
4 - Info: Probe configuration matched.
|
|
5 - Alarm: Communication with battery manager has been lost.
|
|
6 - Info: Communication with battery manager has been restored.
|
|
7 - Alarm: Communication with LCD has been lost.
|
|
8 - Info: Communication with LCD has been restored.
|
|
9 - Warning: Enter battery equalization active mode.
|
|
10- Warning: Leave battery equalization active mode.
|
|
11- Alarm: Battery equalizing has failed.
|
|
12- Info: Battery equalizing succeed.
|
|
|
|
Known Specific Event ID: Battery Probes
|
|
101 - Alarm: Low battery voltage.
|
|
102 - Alarm: High battery voltage.
|
|
103 - Info: Battery voltage event has cleared.
|
|
104 - Alarm: Low battery temperature.
|
|
105 - Alarm: High battery temperature.
|
|
106 - Info: Battery temperature event has cleared.
|
|
107 - Alarm: Critical low battery resistance.
|
|
108 - Alarm: Critical high battery resistance.
|
|
109 - Warning: Low battery resistance.
|
|
110 - Warning: high battery resistance.
|
|
111 - Info: Battery resistance event has cleared.
|
|
112 - Alarm: Battery resistance health has crossed alarm threshold.
|
|
113 - Warning: Battery resistance health has crossed warning threshold.
|
|
114 - Info: Battery resistance health has returned to Normal. "
|
|
::= { mtrapinfo 6 }
|
|
|
|
-- The mcontrol group
|
|
mcontrolRestart OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
restartCurrentSystem (2),
|
|
restartCurrentAgent (3),
|
|
restartCurrentSystemAndAgent (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to restartCurrentSystem (2) will restart the current system.
|
|
Setting this OID to restartCurrentAgent (3) will restart the current agent.
|
|
Setting this OID to restartCurrentSystemAnd Agent (4) will restart the current
|
|
the current system and agent."
|
|
|
|
::= { mcontrol 1 }
|
|
|
|
mcontrolReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
resetCurrentSystem (2),
|
|
resetCurrentAgent (3),
|
|
resetCurrentSystemAndAgent (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to resetCurrentSystem (2) will reset the current system.
|
|
Setting this OID to resetCurrentAgent (3) will reset the current agent.
|
|
Setting this OID to resetCurrentSystemAndAgenta (4) will reset the current
|
|
system and the current agent."
|
|
|
|
::= { mcontrol 2 }
|
|
|
|
-- the ups group
|
|
-- the upsIdent group
|
|
-- the upsBaseIdent
|
|
upsBaseIdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS model name."
|
|
::= { upsBaseIdent 1 }
|
|
|
|
upsBaseIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS identified name could be set by the administrator."
|
|
::= { upsBaseIdent 2 }
|
|
|
|
|
|
-- the upsAdvanceIdent group
|
|
upsAdvanceIdentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS firmware revision."
|
|
::= { upsAdvanceIdent 1 }
|
|
|
|
upsAdvanceIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS manufacture date in mm/dd/yy format."
|
|
::= { upsAdvanceIdent 2 }
|
|
|
|
upsAdvanceIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS serial number in the internal microprocessor."
|
|
::= { upsAdvanceIdent 3 }
|
|
|
|
upsAdvanceIdentAgentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The SNMP agent firmware revision."
|
|
::= { upsAdvanceIdent 4 }
|
|
|
|
upsAdvanceIdentLCDFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision number of the UPS LCD firmware."
|
|
::= { upsAdvanceIdent 5 }
|
|
|
|
upsAdvanceIdentPowerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Volt-Amp rating of the UPS."
|
|
::= { upsAdvanceIdent 6 }
|
|
|
|
upsAdvanceIdentLoadPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power rating(Watts) of the UPS."
|
|
::= { upsAdvanceIdent 7 }
|
|
|
|
upsAdvanceIdentCurrentRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The output current rating of the UPS. Measured in tenths of Amps."
|
|
::= { upsAdvanceIdent 8 }
|
|
|
|
upsAdvanceIdentAgentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string identifying the serial number of the Agent."
|
|
::= { upsAdvanceIdent 9 }
|
|
|
|
-- the upsBattery group
|
|
-- the upsBaseBattery group
|
|
upsBaseBatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryNotPresent(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS battery status. A batteryLow(3) value means the
|
|
battery will be exhausted soon under the current load.
|
|
The amount of low battery run time can be configured by the
|
|
upsAdvanceConfigLowBatteryRunTime."
|
|
::= { upsBaseBattery 1 }
|
|
|
|
upsBaseBatteryTimeOnBattery OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS wasted battery time since the UPS has transfered to
|
|
backup mode."
|
|
::= { upsBaseBattery 2 }
|
|
|
|
upsBaseBatteryLastReplaceDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS batteries last replaced date in mm/dd/yyyy format.
|
|
This value is originally set when manufactured. If batteries
|
|
replaced, administrator should reset this value."
|
|
::= { upsBaseBattery 3 }
|
|
|
|
upsBaseBatteryAgeRecommand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Recommended battery life in month"
|
|
::= { upsBaseBattery 4 }
|
|
|
|
-- the upsAdvanceBattery group
|
|
upsAdvanceBatteryCapacity OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery capacity expressed in percentage."
|
|
::= { upsAdvanceBattery 1 }
|
|
|
|
upsAdvanceBatteryVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery voltage expressed in 1/10 VDC."
|
|
::= { upsAdvanceBattery 2 }
|
|
|
|
upsAdvanceBatteryTemperature OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS battery temperature expressed in Celsius."
|
|
::= { upsAdvanceBattery 3 }
|
|
|
|
upsAdvanceBatteryRunTimeRemaining OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS battery remaining run time."
|
|
::= { upsAdvanceBattery 4 }
|
|
|
|
upsAdvanceBatteryReplaceIndicator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noBatteryNeedsReplacing(1),
|
|
batteryNeedsReplacing(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value indicates if UPS batteries need to be replaced."
|
|
::= { upsAdvanceBattery 5 }
|
|
|
|
upsAdvanceBatteryFullChargeVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery charged voltage expressed in 1/10 VDC."
|
|
::= { upsAdvanceBattery 6 }
|
|
|
|
upsAdvanceBatteryCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery current expressed in percentage."
|
|
::= { upsAdvanceBattery 7 }
|
|
|
|
upsAdvanceBatteryVoltageRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The DC voltage rating of the battery set."
|
|
::= { upsAdvanceBattery 8 }
|
|
|
|
upsAdvanceBatteryLife OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The battery life expressed in 1/100 percentage."
|
|
::= { upsAdvanceBattery 9 }
|
|
|
|
|
|
-- the upsBaseInput group
|
|
upsBaseInputPhase OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The AC input phase."
|
|
::= { upsBaseInput 1 }
|
|
|
|
|
|
-- the upsAdvanceInput group
|
|
upsAdvanceInputLineVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input line voltage in 1/10 VAC."
|
|
::= { upsAdvanceInput 1 }
|
|
|
|
upsAdvanceInputMaxLineVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum input line voltage in 1/10 VAC over the
|
|
previous 1 minute period."
|
|
::= { upsAdvanceInput 2 }
|
|
|
|
upsAdvanceInputMinLineVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum input line voltage in 1/10 VAC over the
|
|
previous 1 minute period."
|
|
::= { upsAdvanceInput 3 }
|
|
|
|
upsAdvanceInputFrequency OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input line frequency in 1/10 Hz."
|
|
::= { upsAdvanceInput 4 }
|
|
|
|
upsAdvanceInputLineFailCause OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTransfer(1),
|
|
highLineVoltage(2),
|
|
brownout(3),
|
|
selfTest(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The reason of UPS power failure.
|
|
This value is set to:
|
|
- noTransfer(1), if UPS is in utility mode.
|
|
- highLineVoltage(2), if UPS switch to battery mode by reason of
|
|
input voltage over the high transfer vloltage.
|
|
- brownout(3), if UPS switch to battery mode by reason of
|
|
input voltage under the low transfer vloltage.
|
|
- selfTest(4), if the UPS was commanded to do a self test."
|
|
::= { upsAdvanceInput 5 }
|
|
|
|
upsAdvanceInputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
overVoltage(2),
|
|
underVoltage(3),
|
|
frequencyFailure(4),
|
|
blackout(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Display the present status of the utility power supplied to the UPS."
|
|
::= { upsAdvanceInput 6 }
|
|
|
|
|
|
-- the upsBaseOutput group
|
|
upsBaseOutputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
onLine(2),
|
|
onBattery(3),
|
|
onBoost(4),
|
|
onSleep(5),
|
|
off(6),
|
|
rebooting(7),
|
|
onECO(8),
|
|
onBypass(9),
|
|
onBuck(10),
|
|
onOverload(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS output status."
|
|
::= { upsBaseOutput 1 }
|
|
|
|
upsBaseOutputPhase OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output phase."
|
|
::= { upsBaseOutput 2 }
|
|
|
|
upsBaseOutputWorkingFrequency OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The frequency of the UPS output power."
|
|
::= { upsBaseOutput 3 }
|
|
|
|
|
|
-- the upsAdvanceOutput group
|
|
upsAdvanceOutputVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS output voltage in 1/10 VAC."
|
|
::= { upsAdvanceOutput 1 }
|
|
|
|
upsAdvanceOutputFrequency OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS output frequency in 1/10 Hz."
|
|
::= { upsAdvanceOutput 2 }
|
|
|
|
upsAdvanceOutputLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS output load expressed in percentage"
|
|
::= { upsAdvanceOutput 3 }
|
|
|
|
upsAdvanceOutputCurrent OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS output current in 1/10 Amps."
|
|
::= { upsAdvanceOutput 4 }
|
|
|
|
upsAdvanceOutputPower OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total output active power of the UPS system in W."
|
|
::= { upsAdvanceOutput 5 }
|
|
|
|
-- the upsBaseConfig group
|
|
upsBaseConfigNumDevices OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of equipment plugged into the UPS."
|
|
::= { upsBaseConfig 1 }
|
|
|
|
upsBaseConfigDeviceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsBaseConfigDeviceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of equipment plugged into the UPS.
|
|
The numbers of entries are given by the value of
|
|
upsBaseConfigNumDevices."
|
|
::= { upsBaseConfig 2 }
|
|
|
|
upsBaseConfigDeviceEntry OBJECT-TYPE
|
|
SYNTAX UpsBaseConfigDeviceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The equipment plugged in to the UPS."
|
|
INDEX { deviceIndex }
|
|
::= { upsBaseConfigDeviceTable 1 }
|
|
|
|
UpsBaseConfigDeviceEntry ::=
|
|
SEQUENCE {
|
|
deviceIndex
|
|
INTEGER,
|
|
deviceName
|
|
DisplayString,
|
|
vaRating
|
|
INTEGER,
|
|
acceptThisDevice
|
|
INTEGER
|
|
}
|
|
|
|
deviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the equipment plugged into the UPS."
|
|
::= { upsBaseConfigDeviceEntry 1 }
|
|
|
|
deviceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the equipment plugged into the UPS."
|
|
::= { upsBaseConfigDeviceEntry 2 }
|
|
|
|
vaRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The VA rating of the equipment plugged into the UPS."
|
|
::= { upsBaseConfigDeviceEntry 3 }
|
|
|
|
acceptThisDevice OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes(1),
|
|
no(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An equipment is plugged if yes, unplugged if no."
|
|
::= { upsBaseConfigDeviceEntry 4 }
|
|
|
|
|
|
-- the upsAdvanceConfig group
|
|
upsAdvanceConfigOutputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The standard UPS output voltage in VAC.
|
|
The possible values are 100, 110, 120, 127,
|
|
208, 220, 230, and 240.
|
|
If a value other than a possible value is set,
|
|
it will not be accepted."
|
|
::= { upsAdvanceConfig 1 }
|
|
|
|
upsAdvanceConfigHighTransferVolt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Adjust the high transfer vloltage in VAC.
|
|
The high transfer vloltage will become the UPS default value
|
|
subtracts this value. The allowed values depend on the output:
|
|
100-127 volt system allow settings of 0-15.
|
|
208-240 volt system allow settings of 0-30.
|
|
If the adjustable value is over the allowed values,
|
|
it will not be accepted."
|
|
::= { upsAdvanceConfig 2 }
|
|
|
|
upsAdvanceConfigLowTransferVolt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Adjust the low transfer vloltage in VAC.
|
|
The low transfer vloltage will become the UPS default value
|
|
adds this value. The allowed values depend on the output:
|
|
100-127 volt system allow settings of 0-15.
|
|
208-240 volt system allow settings of 0-30.
|
|
If the adjustable value is over the allowed values,
|
|
it will not be accepted."
|
|
::= { upsAdvanceConfig 3 }
|
|
|
|
upsAdvanceConfigAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
timed(1),
|
|
enable(2),
|
|
disable(3),
|
|
mute(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value is set to handle audible alarms when power failure."
|
|
::= { upsAdvanceConfig 4 }
|
|
|
|
upsAdvanceConfigAlarmTimer OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time after power failure at which the UPS begins giving
|
|
audible alarms. This timer is effective only if the value of
|
|
upsAdvanceConfigAlarm is timed(1).
|
|
Accepted values are between 0 to 60 seconds.
|
|
If a value other than a supported value is set, the value
|
|
will not be accepted."
|
|
::= { upsAdvanceConfig 5 }
|
|
|
|
upsAdvanceConfigMinReturnCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum battery capacity that UPS will return from
|
|
a low battery shutdown condition. The possible values
|
|
are between 0 to 40.
|
|
If a value other than a supported value is set, the value
|
|
will not be accepted."
|
|
::= { upsAdvanceConfig 6 }
|
|
|
|
upsAdvanceConfigSensitivity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto(1),
|
|
low(2),
|
|
medium(3),
|
|
high(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensitivity of the UPS to power failure detection."
|
|
::= { upsAdvanceConfig 7 }
|
|
|
|
upsAdvanceConfigLowBatteryRunTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The desired run time, in seconds, UPS will enter in a
|
|
low battery sequence. The possible values are
|
|
120, 300, 420, 600.
|
|
If a value other than a supported value is set, the value
|
|
will not be accepted."
|
|
::= { upsAdvanceConfig 8 }
|
|
|
|
upsAdvanceConfigReturnDelay OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay time the UPS will turn on after power recovery.
|
|
The value is also used in a 'reboot' or 'wake up' sequence.
|
|
The possible values are 0 to 600 seconds.
|
|
If a value other than a supported value is set, the value
|
|
will not be accepted."
|
|
::= { upsAdvanceConfig 9 }
|
|
|
|
upsAdvanceConfigShutoffDelay OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay time the UPS will remain on after receiving a
|
|
turn off command. The possible values are between 60 to
|
|
5940 seconds.
|
|
If a value other than a supported value is set, the value
|
|
will not be accepted."
|
|
::= { upsAdvanceConfig 10 }
|
|
|
|
upsAdvanceConfigSleepDelay OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The delay time the UPS will enter sleep mode after receiving
|
|
a sleep command. WThe possible values are between 60 to
|
|
5940 seconds.
|
|
If a value other than a supported value is set, the value
|
|
will not be accepted."
|
|
::= { upsAdvanceConfig 11 }
|
|
|
|
|
|
upsAdvanceConfigSetEEPROMDefaults OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noSetEEPROMDefaults(1),
|
|
setEEPROMDefaults(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the UPS EEPROM parameters to default values."
|
|
::= { upsAdvanceConfig 12 }
|
|
|
|
upsAdvanceConfigAutoRestore OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When this option is enabled, the UPS will restore output
|
|
immediately when the utility power restores.When this option
|
|
is disabled, the UPS will not restore output at that moment
|
|
and users have to turn it on manually at a later time. "
|
|
::= { upsAdvanceConfig 13 }
|
|
|
|
|
|
upsAdvanceConfigRechargedCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" When the utility power restores, the UPS will start to recharge until
|
|
the specified battery capacity in percentage is met before restoring output power.
|
|
The possible values are 0, 15, 30, 45, 60, 75, and 90.
|
|
If a value other than a possible value is set, it will not be accepted."
|
|
::= { upsAdvanceConfig 14 }
|
|
|
|
|
|
upsAdvanceConfigColdStart OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" Set the ability of the UPS can start in the absence of input power.When
|
|
this option is enabled the UPS can be turned on without having input power."
|
|
::= { upsAdvanceConfig 15 }
|
|
|
|
|
|
upsAdvanceConfigDeepDischargeProtection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" When the UPS is on Battery Mode with 0% load and the status remains for
|
|
the time configured,the RMCARD will enforce the UPS to Sleep Mode and
|
|
the output will be turned off. The possible values are 0, 20, 40, and 60 minutes.
|
|
If a value other than a possible value is set, it will not be accepted. "
|
|
::= { upsAdvanceConfig 16 }
|
|
|
|
|
|
|
|
upsAdvanceConfigSleepAfterAllClientShut OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this option is enabled, UPS will enter sleep mode after
|
|
utility power failed and remaining MSDT+2 minutes.More information
|
|
about MSDT please reference to help page of UPS - > PowerPanel List."
|
|
::= { upsAdvanceConfig 17 }
|
|
|
|
|
|
upsAdvanceConfigLowBatteryThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the UPS supplies battery power and the remaining capacity is lower than this threshold,
|
|
the UPS will sound an alarm.
|
|
The value expressed in percentage."
|
|
::= { upsAdvanceConfig 18 }
|
|
|
|
|
|
-- the upsBaseControl group
|
|
upsBaseControlConserveBattery OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTurnOffUps(1),
|
|
turnOffUpsToConserveBattery(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"UPS on battery will enter sleeping when the variable is set
|
|
to turnOffUpsToConserveBattery(2). When utility power recovers
|
|
the UPS will turn back on. Trying to turn off a UPS that is
|
|
not on battery mode will cause badValue error.
|
|
It is no effective to set this value to noTurnOffUps(1)."
|
|
::= { upsBaseControl 1 }
|
|
|
|
|
|
-- the upsAdvanceControl group
|
|
upsAdvanceControlUpsOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTurnUpsOff(1),
|
|
turnUpsOff(2),
|
|
turnUpsOffGracefully(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"UPS will shutdown when the variable is set to turnUpsOff(2).
|
|
UPS will shutdown after a delay period specified by
|
|
upsAdvanceConfigShutoffDelay when the variable is Set to
|
|
turnUpsOffGracefully(3).
|
|
Without regard to the utility state the UPS will not provide
|
|
output power in this state.
|
|
It is no effective to set this value to noTurnUpsOff(1)."
|
|
::= { upsAdvanceControl 1 }
|
|
|
|
upsAdvanceControlRebootUps OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noRebootUps(1),
|
|
rebootUps(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"UPS will shutdown and turn back on when the variable is
|
|
set to rebootUps(2).
|
|
It is no effective to set this value to noRebootUps(1)."
|
|
::= { upsAdvanceControl 2 }
|
|
|
|
upsAdvanceControlUpsSleep OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noPutUpsToSleep(1),
|
|
putUpsToSleep(2),
|
|
putUpsToSleepGracefully(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"UPS will enter sleep mode when the variable is set to putUpsToSleep(2).
|
|
UPS will enter sleep mode after a delay period specified by
|
|
upsAdvanceConfigSleepDelay when the variable is Set to
|
|
putUpsToSleepGracefully(3).
|
|
Without regard to the utility state the UPS will not provide output
|
|
power in sleep mode. Output power will recover when specified time
|
|
has elapsed.
|
|
It is no effective to set this value to noPutUpsToSleep(1)."
|
|
::= { upsAdvanceControl 3 }
|
|
|
|
upsAdvanceControlSimulatePowerFail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noSimulatePowerFailure(1),
|
|
simulatePowerFailure(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"UPS will transfer to backup mode when the variable is set
|
|
to simulatePowerFailure(2).
|
|
It is no effective to set this value to noFlashAndBeep(1)."
|
|
::= { upsAdvanceControl 4 }
|
|
|
|
upsAdvanceControlFlashAndBeep OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noFlashAndBeep(1),
|
|
flashAndBeep(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"UPS will beep and simultaneously turn on the panel lights
|
|
when the variable is set to flashAndBeep(2).
|
|
It is no effective to set this value to noSimulatePowerFailure(1)."
|
|
::= { upsAdvanceControl 5 }
|
|
|
|
upsAdvanceControlTurnOnUPS OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTurnOnUPS(1),
|
|
turnOnUPS(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"UPS will turned on immediately when the variable is set
|
|
to turnOnUPS(2).
|
|
It is no effective to set this value to noTurnOnUPS(1)."
|
|
::= { upsAdvanceControl 6 }
|
|
|
|
upsAdvanceSleepAfterDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..600)
|
|
UNITS "seconds"
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"UPS will enter sleep mode after indicated number of seconds,
|
|
or less if the UPS batteries become depleted. Setting this
|
|
object to 0 will cause the shutdown to occur immediately.
|
|
Setting this object to -1 will abort the countdown."
|
|
::= { upsAdvanceControl 7 }
|
|
|
|
-- the upsTest group
|
|
-- the upsAdvanceTest group
|
|
upsAdvanceTestDiagnosticSchedule OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
biweekly(2),
|
|
weekly(3),
|
|
atTurnOn(4),
|
|
never(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The schedule of the UPS automatic selftest."
|
|
::= { upsAdvanceTest 1 }
|
|
|
|
upsAdvanceTestDiagnostics OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTestDiagnostics(1),
|
|
testDiagnostics(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"UPS will do a diagnostic selftest when the variable is set
|
|
to testDiagnostics(2).
|
|
It is no effective to set this value to noTestDiagnostics(1)."
|
|
::= { upsAdvanceTest 2 }
|
|
|
|
upsAdvanceTestDiagnosticsResults OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
failed(2),
|
|
invalidTest(3),
|
|
testInProgress(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The last UPS selftest result."
|
|
::= { upsAdvanceTest 3 }
|
|
|
|
upsAdvanceTestLastDiagnosticsDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The last UPS selftest date in mm/dd/yy format."
|
|
::= { upsAdvanceTest 4 }
|
|
|
|
upsAdvanceTestIndicators OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTestIndicators(1),
|
|
testIndicators(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"UPS will perform a panel indicator test when the variable
|
|
is set to testIndicators(2).
|
|
It is no effective to set this value to noTestIndicators(1)."
|
|
::= { upsAdvanceTest 5 }
|
|
|
|
upsAdvanceTestRuntimeEstimation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noPerformEstimation(1),
|
|
performEstimation(2),
|
|
cancelCurrentEstimation(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"UPS will discharge to calibrate the UPS runtime when the variable
|
|
is set to performEstimation(2).
|
|
This test runs until the UPS is in a low battery condition.
|
|
UPS will cancel the discharge after setting performEstimation(2)
|
|
when the variable is set to cancelCurrentEstimation(3).
|
|
It is no effective to set this value to noPerformEstimation(1).
|
|
The result of the runtime test will be stored in
|
|
upsAdvanceTestEstimationResults."
|
|
::= { upsAdvanceTest 6 }
|
|
|
|
upsAdvanceTestEstimationResults OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
invalidEstimation(2),
|
|
estimationInProgress(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The last runtime estimation result.
|
|
This value means :
|
|
- ok(1), if a successful runtime estimation.
|
|
- invalidEstimation(2), if runtime estimation failure.
|
|
- estimationInProgress(3), if estimation is processing now."
|
|
::= { upsAdvanceTest 7 }
|
|
|
|
upsAdvanceTestEstimationDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The last UPS runtime estimation date"
|
|
::= { upsAdvanceTest 8 }
|
|
|
|
-- the upsBankOutletControl grop
|
|
upsBankOutletControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsBankOutletControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of the outlet banks."
|
|
::= { upsBankOutletControl 1 }
|
|
|
|
upsBankOutletControlEntry OBJECT-TYPE
|
|
SYNTAX UpsBankOutletControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet to control."
|
|
INDEX { upsBankControlIndex }
|
|
::= { upsBankOutletControlTable 1 }
|
|
|
|
UpsBankOutletControlEntry ::=
|
|
SEQUENCE {
|
|
upsBankControlIndex
|
|
INTEGER,
|
|
upsBankControlOutletCommand
|
|
INTEGER
|
|
}
|
|
|
|
upsBankControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { upsBankOutletControlEntry 1 }
|
|
|
|
upsBankControlOutletCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
immediateOn (1),
|
|
immediateOff (2),
|
|
bankNotExist (3),
|
|
criticalBank (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet bank state. If
|
|
the outlet bank is on, the immediateOn (1) value will be returned.
|
|
If the outlet bank is off, the immediateOff (2) value will be
|
|
returned. If the outlet bank is critical (uncontrollable), the
|
|
criticalBank (4) value will be returned.
|
|
Setting this variable to immediateOn (1) will immediately turn
|
|
the outlet on.
|
|
Setting this variable to immediateOff (2) will immediately turn
|
|
the outlet off."
|
|
::= { upsBankOutletControlEntry 2 }
|
|
|
|
|
|
-- the upsPhase group
|
|
-- the upsPhaseInput group in the upsPhase group
|
|
upsPhaseInputTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase number."
|
|
::= { upsPhaseInput 1 }
|
|
|
|
-- the upsPhaseInputTable in upsPhaseInput group
|
|
upsPhaseInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PhaseInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the Phase Input in the UPS"
|
|
::= { upsPhaseInput 2 }
|
|
upsPhaseInputEntry OBJECT-TYPE
|
|
SYNTAX PhaseInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS Phase Input Access."
|
|
INDEX { upsPhaseInputTableIndex}
|
|
::= { upsPhaseInputTable 1 }
|
|
|
|
PhaseInputEntry ::=
|
|
SEQUENCE {
|
|
upsPhaseInputTableIndex INTEGER,
|
|
upsPhaseInputVoltage INTEGER,
|
|
upsPhaseInputCurrent INTEGER,
|
|
upsPhaseInputFrequency INTEGER,
|
|
upsPhaseInputPowerFactor INTEGER
|
|
}
|
|
upsPhaseInputTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(3)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the UPS Phase Input entry."
|
|
::= { upsPhaseInputEntry 1 }
|
|
|
|
upsPhaseInputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the input voltage that each phase of the UPS can provide. It is represented in 1/10 VAC."
|
|
::= { upsPhaseInputEntry 2 }
|
|
|
|
upsPhaseInputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the input current that each phase of the UPS can provide. It is represented in 1/10 Amps."
|
|
::= { upsPhaseInputEntry 3 }
|
|
upsPhaseInputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the input frequency that each phase of the UPS can provide. It is represented in 1/10 Hz."
|
|
::= { upsPhaseInputEntry 4 }
|
|
upsPhaseInputPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the input power factor that each phase of the UPS can provide. It is represented in 1/100."
|
|
::= { upsPhaseInputEntry 5 }
|
|
|
|
|
|
-- the upsPhaseOutput group in the upsPhase group
|
|
upsPhaseOutputTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Phase number."
|
|
::= { upsPhaseOutput 1 }
|
|
|
|
-- the upsPhaseOutputTable in upsPhaseOutput group
|
|
upsPhaseOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PhaseOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the Phase Output in the UPS"
|
|
::= { upsPhaseOutput 2 }
|
|
|
|
upsPhaseOutputEntry OBJECT-TYPE
|
|
SYNTAX PhaseOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS Phase Output Access."
|
|
INDEX { upsPhaseOutputTableIndex}
|
|
::= { upsPhaseOutputTable 1 }
|
|
|
|
PhaseOutputEntry ::=
|
|
SEQUENCE {
|
|
upsPhaseOutputTableIndex INTEGER,
|
|
upsPhaseOutputVoltage INTEGER,
|
|
upsPhaseOutputCurrent INTEGER,
|
|
upsPhaseOutputFrequency INTEGER,
|
|
upsPhaseOutputPowerFactor INTEGER,
|
|
upsPhaseOutputPower INTEGER
|
|
}
|
|
|
|
|
|
upsPhaseOutputTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(3)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the UPS Phase Output entry."
|
|
::= { upsPhaseOutputEntry 1 }
|
|
|
|
upsPhaseOutputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the output voltage that each phase of the UPS can provide. It is represented in 1/10 VAC."
|
|
::= { upsPhaseOutputEntry 2 }
|
|
|
|
upsPhaseOutputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the output current that each phase of the UPS can provide. It is represented in 1/10 Amps."
|
|
::= { upsPhaseOutputEntry 3 }
|
|
upsPhaseOutputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the output frequency that each phase of the UPS can provide. It is represented in 1/10 Hz."
|
|
::= { upsPhaseOutputEntry 4 }
|
|
upsPhaseOutputPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the output power factor that each phase of the UPS can provide. It is represented in 1/100."
|
|
::= { upsPhaseOutputEntry 5 }
|
|
upsPhaseOutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the output power that each phase of the UPS can provide. It is represented in Watt."
|
|
::= { upsPhaseOutputEntry 6 }
|
|
|
|
-- the upsPhaseBypass group in the upsPhase group
|
|
upsPhaseBypassTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Phase number."
|
|
::= { upsPhaseBypass 1 }
|
|
|
|
-- the upsPhaseBypassTable in upsPhaseBypass group
|
|
upsPhaseBypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PhaseBypassEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the Phase Bypass in the UPS"
|
|
::= { upsPhaseBypass 2 }
|
|
|
|
upsPhaseBypassEntry OBJECT-TYPE
|
|
SYNTAX PhaseBypassEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS Phase Bypass Access."
|
|
INDEX { upsPhaseBypassTableIndex}
|
|
::= { upsPhaseBypassTable 1 }
|
|
|
|
PhaseBypassEntry ::=
|
|
SEQUENCE {
|
|
upsPhaseBypassTableIndex INTEGER,
|
|
upsPhaseBypassVoltage INTEGER,
|
|
upsPhaseBypassCurrent INTEGER,
|
|
upsPhaseBypassFrequency INTEGER,
|
|
upsPhaseBypassPowerFactor INTEGER
|
|
}
|
|
|
|
|
|
upsPhaseBypassTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(3)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the UPS Phase Bypass entry."
|
|
::= { upsPhaseBypassEntry 1 }
|
|
|
|
upsPhaseBypassVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bypass voltage that each phase of the UPS can provide. It is represented in 1/10 VAC."
|
|
::= { upsPhaseBypassEntry 2 }
|
|
|
|
upsPhaseBypassCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bypass current that each phase of the UPS can provide. It is represented in 1/10 Amps."
|
|
::= { upsPhaseBypassEntry 3 }
|
|
upsPhaseBypassFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bypass frequency that each phase of the UPS can provide. It is represented in 1/10 Hz."
|
|
::= { upsPhaseBypassEntry 4 }
|
|
upsPhaseBypassPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bypass power factor that each phase of the UPS can provide. It is represented in 1/100."
|
|
::= { upsPhaseBypassEntry 5 }
|
|
|
|
-- upsSystem Group
|
|
upsStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
overheat (2),
|
|
hardwarefault (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UPS system status."
|
|
::= { upsSystem 1 }
|
|
|
|
-- the eswitch group
|
|
-- the eSwitchIdent group
|
|
eSwitchIdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision set at the factory."
|
|
::= { eSwitchIdent 1 }
|
|
|
|
eSwitchIdentFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision set at the factory."
|
|
::= { eSwitchIdent 2 }
|
|
|
|
eSwitchIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The manufacture date in mm/dd/yy format."
|
|
::= { eSwitchIdent 3 }
|
|
|
|
eSwitchIdentModelName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The model name set at the factory.
|
|
This value need to consist with safty report."
|
|
::= { eSwitchIdent 4 }
|
|
|
|
|
|
-- the eSwitchBase group
|
|
eSwitchNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numbers of switch have been attached to the system."
|
|
::= { eSwitchBase 1 }
|
|
|
|
eSwitchBaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ESwitchBaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of switch information. The number of entries is given
|
|
by the value of eSwitchNumber."
|
|
::= { eSwitchBase 2 }
|
|
|
|
eSwitchBaseEntry OBJECT-TYPE
|
|
SYNTAX ESwitchBaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry information of the individual switch."
|
|
INDEX { eSwitchID}
|
|
::= { eSwitchBaseTable 1 }
|
|
|
|
ESwitchBaseEntry ::=
|
|
SEQUENCE {
|
|
eSwitchID
|
|
INTEGER,
|
|
eSwitchOutletNum
|
|
INTEGER,
|
|
eSwitchOutletState
|
|
DisplayString
|
|
}
|
|
|
|
eSwitchID OBJECT-TYPE
|
|
SYNTAX INTEGER(0..16)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power switch ID number."
|
|
::= { eSwitchBaseEntry 1 }
|
|
|
|
eSwitchOutletNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of outlets provided in the switch."
|
|
::= { eSwitchBaseEntry 2 }
|
|
|
|
eSwitchOutletState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will reply the status of all outlets in the switch.
|
|
'0' for outlet off, '1' for outlet on.
|
|
The index from left to right is outlet#8, #7, #6, #5, #4, #3, #2, #1.
|
|
For Example:
|
|
If the string is '01011010', it means the outlets status are the following:
|
|
outlet #8 is off,
|
|
outlet #7 is on,
|
|
outlet #6 is off,
|
|
outlet #5 is on,
|
|
outlet #4 is on,
|
|
outlet #3 is off,
|
|
outlet #2 is on,
|
|
outlet #1 is off.
|
|
"
|
|
::= { eSwitchBaseEntry 3 }
|
|
|
|
eSwitchBaseCtrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ESwitchBaseCtrEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of switch control parameters. The number of entries is given
|
|
by the value of eSwitchNumber."
|
|
::= { eSwitchBase 3 }
|
|
|
|
eSwitchBaseCtrEntry OBJECT-TYPE
|
|
SYNTAX ESwitchBaseCtrEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry control information of individual switches."
|
|
INDEX { eSwitchCtrID}
|
|
::= { eSwitchBaseCtrTable 1 }
|
|
|
|
ESwitchBaseCtrEntry ::=
|
|
SEQUENCE {
|
|
eSwitchCtrID
|
|
INTEGER,
|
|
eSwitchActOutlet
|
|
INTEGER,
|
|
eSwitchActType
|
|
INTEGER
|
|
}
|
|
|
|
eSwitchCtrID OBJECT-TYPE
|
|
SYNTAX INTEGER(0..16)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Select the switch ID to be controlled."
|
|
::= { eSwitchBaseCtrEntry 1 }
|
|
|
|
eSwitchActOutlet OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The action outlets to be controlled."
|
|
::= { eSwitchBaseCtrEntry 2 }
|
|
|
|
eSwitchActType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The on/off type of the action outlets.
|
|
1 for duration off, 2 for duration on,
|
|
3 for immediately off, 4 for immediately on,
|
|
and 5 for reboot."
|
|
::= { eSwitchBaseCtrEntry 3 }
|
|
|
|
|
|
|
|
-- ePDU Group
|
|
|
|
-- the ePDUIdent group
|
|
|
|
ePDUIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the Rack PDU.
|
|
The maximum string size is device dependent."
|
|
::= { ePDUIdent 1 }
|
|
|
|
ePDUIdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the Rack PDU.
|
|
This value is set at the factory."
|
|
::= { ePDUIdent 2 }
|
|
|
|
ePDUIdentFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An 8-byte ID string identifying the Rack PDU firmware revision.
|
|
This value is set at the factory."
|
|
::= { ePDUIdent 3 }
|
|
|
|
|
|
ePDUIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the Rack PDU was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory. The year 2000 will be
|
|
represented by 00."
|
|
::= { ePDUIdent 4 }
|
|
|
|
ePDUIdentModelNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A 10-character string identifying the model number of
|
|
the Rack PDU. This value is set at the factory."
|
|
::= { ePDUIdent 5 }
|
|
|
|
ePDUIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A 12-character string identifying the serial number of
|
|
the Rack PDU. This value is set at the factory."
|
|
::= { ePDUIdent 6 }
|
|
|
|
ePDUIdentDeviceRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the electrical rating of the device."
|
|
|
|
::= { ePDUIdent 7 }
|
|
|
|
ePDUIdentDeviceNumOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the number of outlets contained in the device."
|
|
|
|
::= { ePDUIdent 8 }
|
|
|
|
ePDUIdentDeviceNumPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the number of phases supported by the device."
|
|
|
|
::= { ePDUIdent 9 }
|
|
|
|
ePDUIdentDeviceNumBreakers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the number of circuit breakers supported by the device.
|
|
This is the same as the number of banks of outlets.
|
|
0 will be returned if the unit has no phase breakers. "
|
|
|
|
::= { ePDUIdent 10 }
|
|
|
|
ePDUIdentDeviceBreakerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return rating of the circuit breakers on the device if it has any."
|
|
|
|
::= { ePDUIdent 11 }
|
|
|
|
ePDUIdentDeviceOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
orientHorizontal (1),
|
|
orientVertical (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the intended physical orientation of the device.
|
|
|
|
OrientHorizonatal(1) indicates Horizontal.
|
|
OrientVertical(2) indicates Vertical."
|
|
|
|
::= { ePDUIdent 12 }
|
|
|
|
ePDUIdentDeviceOutletLayout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
seqPhaseToNeutral (1),
|
|
seqPhaseToPhase (2),
|
|
seqPhToNeu21PhToPh (3),
|
|
seqPhToPhGrouped (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return outlet layout for the device.
|
|
|
|
SeqPhaseToNeutral(1) indicates outlet layout as follows:
|
|
1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
|
|
|
|
SeqPhaseToPhase(2) indicates outlet layout as follows:
|
|
1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,...
|
|
|
|
SeqPhToNeu21PhToPh(3) indicates outlet layout as follows:
|
|
1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,...
|
|
|
|
SeqPhToPhGrouped(4) indicates outlet layout as follows:
|
|
Otlts1-8::(3-1),Otlts9-16::(2-3),Otlts17-24::(1-2)."
|
|
::= { ePDUIdent 13 }
|
|
|
|
ePDUIdentDeviceDisplayOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
displayNormal (1),
|
|
displayReverse (2),
|
|
displayRotate90 (3),
|
|
displayRotate270 (4),
|
|
displayAuto (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the intended physical orientation of the Seven-Segment Display.
|
|
|
|
displayNormal(1) indicates Normal.
|
|
displayReverse(2)indicates Upside-Down.
|
|
displayRotate90(3) indicates rotate 90 degree.
|
|
displayRotate270(4) indicates rotate 270 degree.
|
|
displayAuto(5) indicates auto-detect and rotate."
|
|
|
|
::= { ePDUIdent 14 }
|
|
|
|
|
|
ePDUIdentDeviceLinetoLineVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting/Setting this OID will return/set the Line to Line Volatage.
|
|
|
|
The valid range is between 0V to 440V"
|
|
|
|
::= { ePDUIdent 15 }
|
|
|
|
ePDUIdentIndicator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTestIndicators(1),
|
|
testIndicators(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PDU will perform a panel indicator test when the variable
|
|
is set to testIndicators(2).
|
|
|
|
It is no effective to set this value to noTestIndicators(1)."
|
|
|
|
::= { ePDUIdent 16 }
|
|
|
|
-- the ePDULoadDevice group
|
|
|
|
ePDULoadDevMaxPhaseLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the maximum rated power
|
|
that each phase of the Rack PDU can provide. It is
|
|
represented in Amps.
|
|
|
|
0 will be returned if the unit is banked."
|
|
::= { ePDULoadDevice 1 }
|
|
|
|
ePDULoadDevNumPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of phases available with this Rack PDU."
|
|
::= { ePDULoadDevice 2 }
|
|
|
|
ePDULoadDevMaxBankLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the maximum rated power
|
|
that a bank of the Rack PDU can provide. It is
|
|
represented in Amps.
|
|
|
|
0 will be returned if the device does not have any banks."
|
|
|
|
::= { ePDULoadDevice 3 }
|
|
|
|
ePDULoadDevNumBanks OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of banks of outlets available with this Rack PDU.
|
|
A bank of outlets has a unique circuit breaker for a subset
|
|
of the total number of outlets on the ePDU.
|
|
|
|
0 will be returned if the unit no banks."
|
|
::= { ePDULoadDevice 4 }
|
|
|
|
ePDULoadDevBankTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Bank Table."
|
|
::= { ePDULoadDevice 5 }
|
|
|
|
|
|
ePDULoadDevBankTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LoadDevBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the Bank Max Load in the Rack PDU."
|
|
|
|
::= { ePDULoadDevice 6 }
|
|
|
|
ePDULoadDevBankEntry OBJECT-TYPE
|
|
SYNTAX LoadDevBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU Banks Access."
|
|
INDEX { ePDULoadDevBankIndex}
|
|
::= { ePDULoadDevBankTable 1 }
|
|
|
|
LoadDevBankEntry ::=
|
|
SEQUENCE {
|
|
ePDULoadDevBankIndex INTEGER,
|
|
ePDULoadDevBankNumber INTEGER,
|
|
ePDULoadDevBankMaxLoad INTEGER
|
|
}
|
|
|
|
ePDULoadDevBankIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU bank entry."
|
|
::= { ePDULoadDevBankEntry 1 }
|
|
|
|
ePDULoadDevBankNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bank number."
|
|
|
|
::= { ePDULoadDevBankEntry 2 }
|
|
|
|
ePDULoadDevBankMaxLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the maximum rated power
|
|
that each bank of the Rack PDU can provide. It is
|
|
represented in Amps."
|
|
|
|
::= { ePDULoadDevBankEntry 3 }
|
|
|
|
ePDULoadDevMaxOutletTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Outlet Table."
|
|
::= { ePDULoadDevice 7 }
|
|
|
|
|
|
ePDULoadDevMaxOutletTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LoadDevMaxOutletEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the Max Outlet Load in an Outlet Monitored Rack PDU."
|
|
::= { ePDULoadDevice 8 }
|
|
|
|
ePDULoadDevMaxOutletEntry OBJECT-TYPE
|
|
SYNTAX LoadDevMaxOutletEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to Max Outlet Load of an Outlet Monitored Rack PDU"
|
|
INDEX { ePDULoadDevOutletIndex}
|
|
::= { ePDULoadDevMaxOutletTable 1 }
|
|
|
|
LoadDevMaxOutletEntry ::=
|
|
SEQUENCE {
|
|
ePDULoadDevOutletIndex INTEGER,
|
|
ePDULoadDevOutletNumber INTEGER,
|
|
ePDULoadDevMaxOutletLoad INTEGER
|
|
}
|
|
|
|
ePDULoadDevOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Outlet Monitored Rack PDU Max Outlet Load entry."
|
|
::= { ePDULoadDevMaxOutletEntry 1 }
|
|
|
|
ePDULoadDevOutletNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Outlet number."
|
|
::= { ePDULoadDevMaxOutletEntry 2 }
|
|
|
|
|
|
ePDULoadDevMaxOutletLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the maximum rated power
|
|
that each Outlet of an Outlet Monitored Rack PDU can provide. It is
|
|
represented in Amps. "
|
|
::= { ePDULoadDevMaxOutletEntry 3 }
|
|
|
|
|
|
-- the ePDULoadPhaseConfig group
|
|
|
|
ePDULoadPhaseConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LoadPhaseConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of each Rack PDU phase.
|
|
The number of entries is contained in the
|
|
ePDULoadDevNumPhases OID."
|
|
::= { ePDULoadPhaseConfig 1 }
|
|
|
|
ePDULoadPhaseConfigEntry OBJECT-TYPE
|
|
SYNTAX LoadPhaseConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU phase to configure."
|
|
INDEX { ePDULoadPhaseConfigIndex}
|
|
::= { ePDULoadPhaseConfigTable 1 }
|
|
|
|
LoadPhaseConfigEntry ::=
|
|
SEQUENCE {
|
|
ePDULoadPhaseConfigIndex INTEGER,
|
|
ePDULoadPhaseConfigLowLoadThreshold INTEGER,
|
|
ePDULoadPhaseConfigNearOverloadThreshold INTEGER,
|
|
ePDULoadPhaseConfigOverloadThreshold INTEGER,
|
|
ePDULoadPhaseConfigAlarm INTEGER
|
|
}
|
|
|
|
ePDULoadPhaseConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase entry."
|
|
::= { ePDULoadPhaseConfigEntry 1 }
|
|
|
|
ePDULoadPhaseConfigLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing a low consumption condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is less than the threshold value.
|
|
|
|
A threshold value of 0 Amps effectively disables this
|
|
warning.
|
|
|
|
Maximum value must be less than the value returned
|
|
by the ePDULoadPhaseConfigNearOverloadThreshold OID."
|
|
::= { ePDULoadPhaseConfigEntry 2 }
|
|
|
|
ePDULoadPhaseConfigNearOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value.
|
|
|
|
Minimum value must be greater than the value returned by
|
|
the ePDULoadPhaseConfigLowLoadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the ePDULoadPhaseConfigOverloadThreshold OID."
|
|
::= { ePDULoadPhaseConfigEntry 3 }
|
|
|
|
ePDULoadPhaseConfigOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load has entered an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value.
|
|
|
|
Minimum value must be greater than or equal to the value
|
|
returned by the ePDULoadPhaseConfigNearOverloadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the ePDULoadDevMaxPhaseLoad OID."
|
|
::= { ePDULoadPhaseConfigEntry 4 }
|
|
|
|
|
|
ePDULoadPhaseConfigAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noLoadAlarm (1),
|
|
underCurrentAlarm (2),
|
|
nearOverCurrentAlarm (3),
|
|
overCurrentAlarm (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the current Phase Alarm."
|
|
::= { ePDULoadPhaseConfigEntry 5 }
|
|
|
|
|
|
-- the ePDULoadStatus group
|
|
|
|
ePDULoadStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LoadStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of each Rack PDU phase/bank.
|
|
The number of entries is calculated by adding
|
|
the number of phases (ePDULoadDevNumPhases OID) and
|
|
the number of banks of outlets (ePDULoadDevNumBanks)
|
|
Number of entries = #phases + #banks.
|
|
NOTE: If a device has phase and bank information, all phase information
|
|
shall precede the bank information."
|
|
::= { ePDULoadStatus 1 }
|
|
|
|
ePDULoadStatusEntry OBJECT-TYPE
|
|
SYNTAX LoadStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU phase/bank to gather status from."
|
|
INDEX { ePDULoadStatusIndex}
|
|
::= { ePDULoadStatusTable 1 }
|
|
|
|
LoadStatusEntry ::=
|
|
SEQUENCE {
|
|
ePDULoadStatusIndex INTEGER,
|
|
ePDULoadStatusLoad Gauge,
|
|
ePDULoadStatusLoadState INTEGER,
|
|
ePDULoadStatusPhaseNumber INTEGER,
|
|
ePDULoadStatusBankNumber INTEGER,
|
|
ePDULoadStatusVoltage INTEGER,
|
|
ePDULoadStatusActivePower INTEGER,
|
|
ePDULoadStatusApparentPower INTEGER,
|
|
ePDULoadStatusPowerFactor INTEGER,
|
|
ePDULoadStatusEnergy INTEGER,
|
|
ePDULoadStatusEnergyStartTime DisplayString
|
|
}
|
|
|
|
ePDULoadStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase/bank entry. All phase information will precede
|
|
any bank information"
|
|
::= { ePDULoadStatusEntry 1 }
|
|
|
|
ePDULoadStatusLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase/bank load measured
|
|
in tenths of Amps."
|
|
::= { ePDULoadStatusEntry 2 }
|
|
|
|
ePDULoadStatusLoadState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
loadNormal (1),
|
|
loadLow (2),
|
|
loadNearOverload (3),
|
|
loadOverload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase/bank load state.
|
|
|
|
loadNormal(1) indicates that the phase/bank is operating
|
|
properly within the ePDULoadConfigLowLoadThreshold
|
|
and ePDULoadConfigNearOverloadThreshold OID values.
|
|
|
|
loadLow(2) indicates that the phase/bank load has dropped
|
|
below the ePDULoadConfigLowLoadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
loadNearOverload(3) indicates that the phase/bank load is
|
|
greater than or equal to the ePDULoadConfigNearOverloadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
loadOverload(4) indicates that the phase/bank load is greater
|
|
than or equal to the ePDULoadConfigOverloadThreshold
|
|
OID value.
|
|
|
|
An SNMP trap will occur when this state is entered or cleared."
|
|
::= { ePDULoadStatusEntry 3 }
|
|
|
|
ePDULoadStatusPhaseNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase number to which this record refers."
|
|
::= { ePDULoadStatusEntry 4 }
|
|
|
|
ePDULoadStatusBankNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank number to which this record refers. A value of 0 will be returned if
|
|
any bank is not present or if it is phase related."
|
|
::= { ePDULoadStatusEntry 5 }
|
|
|
|
ePDULoadStatusVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase/bank voltage measured
|
|
in 0.1 volts."
|
|
::= { ePDULoadStatusEntry 6 }
|
|
|
|
ePDULoadStatusActivePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase/bank active power measured
|
|
in watts."
|
|
::= { ePDULoadStatusEntry 7 }
|
|
|
|
ePDULoadStatusApparentPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase/bank apparent power measured
|
|
in VA."
|
|
::= { ePDULoadStatusEntry 8 }
|
|
|
|
ePDULoadStatusPowerFactor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return power factor of the output measured in hundredths.
|
|
A value of 100 representing a unity power factor (1.00)."
|
|
::= { ePDULoadStatusEntry 9 }
|
|
|
|
ePDULoadStatusEnergy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase/bank apparent power measured
|
|
in 0.1 kilowatt-hours."
|
|
::= { ePDULoadStatusEntry 10 }
|
|
|
|
ePDULoadStatusEnergyStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the date and time of the last energy
|
|
meter reset"
|
|
::= { ePDULoadStatusEntry 11 }
|
|
|
|
-- the ePDULoadBankConfig group
|
|
|
|
ePDULoadBankConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LoadBankConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of each Rack PDU bank.
|
|
The number of entries is contained in the
|
|
ePDULoadDevNumBanks OID."
|
|
::= { ePDULoadBankConfig 1 }
|
|
|
|
ePDULoadBankConfigEntry OBJECT-TYPE
|
|
SYNTAX LoadBankConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU bank to configure."
|
|
INDEX { ePDULoadBankConfigIndex}
|
|
::= { ePDULoadBankConfigTable 1 }
|
|
|
|
LoadBankConfigEntry ::=
|
|
SEQUENCE {
|
|
ePDULoadBankConfigIndex INTEGER,
|
|
ePDULoadBankConfigLowLoadThreshold INTEGER,
|
|
ePDULoadBankConfigNearOverloadThreshold INTEGER,
|
|
ePDULoadBankConfigOverloadThreshold INTEGER,
|
|
ePDULoadBankConfigAlarm INTEGER
|
|
}
|
|
|
|
ePDULoadBankConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU bank entry."
|
|
::= { ePDULoadBankConfigEntry 1 }
|
|
|
|
ePDULoadBankConfigLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing a low consumption condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is less than the threshold value.
|
|
|
|
A threshold value of 0 Amps effectively disables this
|
|
warning.
|
|
|
|
Maximum value must be less than the value returned
|
|
by the ePDULoadBankConfigNearOverloadThreshold OID."
|
|
|
|
::= { ePDULoadBankConfigEntry 2 }
|
|
|
|
ePDULoadBankConfigNearOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value.
|
|
|
|
Minimum value must be greater than the value returned by
|
|
the ePDULoadBankConfigLowLoadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the ePDULoadBankConfigOverloadThreshold OID."
|
|
|
|
::= { ePDULoadBankConfigEntry 3 }
|
|
|
|
ePDULoadBankConfigOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load has entered an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value.
|
|
|
|
Minimum value must be greater than or equal to the value
|
|
returned by the ePDULoadBankConfigNearOverloadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the ePDULoadDevMaxBankLoad OID."
|
|
|
|
::= { ePDULoadBankConfigEntry 4 }
|
|
|
|
ePDULoadBankConfigAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noLoadAlarm (1),
|
|
underCurrentAlarm (2),
|
|
nearOverCurrentAlarm (3),
|
|
overCurrentAlarm (4)
|
|
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" Getting this OID will return the current Bank Alarm."
|
|
::= { ePDULoadBankConfigEntry 5 }
|
|
|
|
|
|
-- the ePDUOutletDevice group
|
|
|
|
ePDUOutletDevCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noCommandAll (1),
|
|
immediateAllOn (2),
|
|
immediateAllOff (3),
|
|
immediateAllReboot (4),
|
|
delayedAllOn (5),
|
|
delayedAllOff (6),
|
|
delayedAllReboot (7),
|
|
cancelAllPendingCommands (8)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to immediateAllOn (2) will turn all outlets
|
|
on immediately.
|
|
|
|
Setting this OID to immediateAllOff (3) will turn all outlets
|
|
off immediately.
|
|
|
|
Setting this OID to immediateAllReboot (4) will reboot all outlets
|
|
immediately.
|
|
|
|
Setting this OID to delayedAllOn (5) will turn all outlets on as
|
|
defined by each outlet's ePDUOutletConfigPowerOnTime OID value.
|
|
|
|
Setting this OID to delayedAllOff (6) will turn all outlets
|
|
off as defined by each outlet's ePDUOutletConfigPowerOffTime OID value.
|
|
|
|
Setting this OID to delayedAllReboot (7) will cause a
|
|
delayedAllOff command to be performed. Once all outlets are off,
|
|
the Switched Rack PDU will then delay the largest
|
|
ePDUOutletConfigRebootDuration OID time, and then perform a
|
|
delayedAllOn command.
|
|
|
|
Setting this OID to cancelAllPendingCommands (8) will cause all pending
|
|
commands on the Switched Rack PDU to be canceled.
|
|
|
|
Getting this OID will return the noCommandAll (1) value."
|
|
::= { ePDUOutletDevice 1 }
|
|
|
|
ePDUOutletDevColdstartDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of delay, in seconds, between when
|
|
power is provided to the Switched Rack PDU and
|
|
when the Switched Rack PDU provides basic master
|
|
power to the outlets.
|
|
|
|
Allowed values are:
|
|
|
|
-1 - never apply power automatically.
|
|
0 - apply power immediately.
|
|
1 to 300 - delay up to 300 seconds (5 minutes)."
|
|
::= { ePDUOutletDevice 2 }
|
|
|
|
ePDUOutletDevNumCntrlOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of controlled outlets on this Switched Rack PDU."
|
|
::= { ePDUOutletDevice 3 }
|
|
|
|
ePDUOutletDevNumTotalOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of outlets on this Rack PDU."
|
|
::= { ePDUOutletDevice 4 }
|
|
|
|
ePDUOutletDevMonitoredOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of monitored outlets on this Rack PDU."
|
|
::= { ePDUOutletDevice 5 }
|
|
|
|
ePDUOutletDevColdstartState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allOn (1),
|
|
previous (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ePDU outlet state after coldstart.
|
|
Allowed values are:
|
|
1 - all outlets on after coldstart.
|
|
2 - outlet status same as previous state."
|
|
::= { ePDUOutletDevice 6 }
|
|
|
|
-- the ePDUOutletPhase group
|
|
|
|
ePDUOutletPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for management of outlets on a per phase basis."
|
|
::= { ePDUOutletPhase 1 }
|
|
|
|
ePDUOutletPhaseEntry OBJECT-TYPE
|
|
SYNTAX OutletPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase to manage."
|
|
INDEX { ePDUOutletPhaseIndex}
|
|
::= { ePDUOutletPhaseTable 1 }
|
|
|
|
OutletPhaseEntry ::=
|
|
SEQUENCE {
|
|
ePDUOutletPhaseIndex INTEGER,
|
|
ePDUOutletPhaseOverloadRestriction INTEGER
|
|
}
|
|
|
|
ePDUOutletPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Switched Rack PDU phase entry."
|
|
::= { ePDUOutletPhaseEntry 1 }
|
|
|
|
ePDUOutletPhaseOverloadRestriction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysAllowTurnON (1),
|
|
restrictOnNearOverload (2),
|
|
restrictOnOverload (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID controls the behavior of a Switched Rack PDU
|
|
phase when an overload condition is possible and
|
|
additional outlets are requested to be turned on.
|
|
|
|
Setting this OID to alwaysAllowTurnON (1) will always allow
|
|
the outlets on the corresponding phase to turn on.
|
|
|
|
Setting this OID to restrictOnNearOverload (2) will not allow
|
|
outlets on the corresponding phase to turn on if the
|
|
ePDULoadConfigNearOverloadThreshold OID is exceeded.
|
|
|
|
Setting this OID to restrictOnOverload (3) will not allow
|
|
outlets on the corresponding phase to turn on if the
|
|
ePDULoadConfigOverloadThreshold OID is exceeded."
|
|
::= { ePDUOutletPhaseEntry 2 }
|
|
|
|
|
|
|
|
-- the ePDUOutletControl group
|
|
|
|
ePDUOutletControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDUOutletControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of the individual outlets.
|
|
The number of entries is contained in the
|
|
ePDUOutletDevNumCntrlOutlets OID."
|
|
::= { ePDUOutletControl 1 }
|
|
|
|
ePDUOutletControlEntry OBJECT-TYPE
|
|
SYNTAX EPDUOutletControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet to control."
|
|
INDEX { ePDUOutletControlIndex}
|
|
::= { ePDUOutletControlTable 1 }
|
|
|
|
EPDUOutletControlEntry ::=
|
|
SEQUENCE {
|
|
ePDUOutletControlIndex INTEGER,
|
|
ePDUOutletControlOutletName DisplayString,
|
|
ePDUOutletControlOutletPhase INTEGER,
|
|
ePDUOutletControlOutletCommand INTEGER,
|
|
ePDUOutletControlOutletBank INTEGER
|
|
}
|
|
|
|
ePDUOutletControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { ePDUOutletControlEntry 1 }
|
|
|
|
ePDUOutletControlOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum string size is device dependent.
|
|
An error will be returned if the set request exceeds the max size.
|
|
This OID is provided for informational purposes only."
|
|
::= { ePDUOutletControlEntry 2 }
|
|
|
|
ePDUOutletControlOutletPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3),
|
|
phase1-2 (4),
|
|
phase2-3 (5),
|
|
phase3-1 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase/s associated with this outlet.
|
|
|
|
For single phase devices, this object will always
|
|
return phase1(1).
|
|
|
|
For 3-phase devices, this object will return phase1 (1),
|
|
phase2 (2), or phase3 (3) for outlets tied to a single
|
|
phase. For outlets tied to two phases, this object will
|
|
return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
|
|
phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
|
|
::= { ePDUOutletControlEntry 3 }
|
|
|
|
ePDUOutletControlOutletCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
immediateOn (1),
|
|
immediateOff (2),
|
|
immediateReboot (3),
|
|
delayedOn (4),
|
|
delayedOff (5),
|
|
delayedReboot (6),
|
|
cancelPendingCommand (7),
|
|
outletIdentify (8)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the immediateOn (1) value will be returned.
|
|
If the outlet is off, the immediateOff (2) value will be
|
|
returned.
|
|
|
|
|
|
Setting this variable to immediateOn (1) will immediately turn
|
|
the outlet on.
|
|
|
|
Setting this variable to immediateOff (2) will immediately turn
|
|
the outlet off.
|
|
|
|
Setting this variable to immediateReboot (3) will immediately
|
|
reboot the outlet.
|
|
|
|
Setting this variable to delayedOn (4) will turn the outlet on
|
|
after the ePDUOutletConfigPowerOnTime OID time has elapsed.
|
|
|
|
Setting this variable to delayedOff (5) will turn the outlet off
|
|
after the ePDUOutletConfigPowerOffTime OID time has elapsed.
|
|
|
|
Setting this variable to delayedReboot (6) will cause the
|
|
Switched Rack PDU to perform a delayedOff command, wait the
|
|
ePDUOutletConfigRebootDuration OID time, and then perform a
|
|
delayedOn command.
|
|
|
|
Setting this variable to cancelPendingCommand (7) will cause any
|
|
pending command to this outlet to be canceled.
|
|
|
|
Setting this variable to outletIdentify (8) will cause PDU LED
|
|
to display the number of the outlet."
|
|
|
|
::= { ePDUOutletControlEntry 4 }
|
|
|
|
ePDUOutletControlOutletBank OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank associated with this outlet."
|
|
::= { ePDUOutletControlEntry 5 }
|
|
|
|
|
|
|
|
-- the ePDUOutletConfig group
|
|
|
|
ePDUOutletConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDUOutletConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual outlets. The number of
|
|
entries is contained in the ePDUOutletDevNumCntrlOutlets OID."
|
|
::= { ePDUOutletConfig 1 }
|
|
|
|
ePDUOutletConfigEntry OBJECT-TYPE
|
|
SYNTAX EPDUOutletConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet to configure."
|
|
INDEX { ePDUOutletConfigIndex}
|
|
::= { ePDUOutletConfigTable 1 }
|
|
|
|
EPDUOutletConfigEntry ::=
|
|
SEQUENCE {
|
|
ePDUOutletConfigIndex INTEGER,
|
|
ePDUOutletConfigOutletName DisplayString,
|
|
ePDUOutletConfigOutletPhase INTEGER,
|
|
ePDUOutletConfigPowerOnTime INTEGER,
|
|
ePDUOutletConfigPowerOffTime INTEGER,
|
|
ePDUOutletConfigRebootDuration INTEGER,
|
|
ePDUOutletConfigOutletBank INTEGER
|
|
}
|
|
|
|
ePDUOutletConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { ePDUOutletConfigEntry 1 }
|
|
|
|
ePDUOutletConfigOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum string size is device dependent.
|
|
An error will be returned if the set request exceeds the max size."
|
|
::= { ePDUOutletConfigEntry 2 }
|
|
|
|
ePDUOutletConfigOutletPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3),
|
|
phase1-2 (4),
|
|
phase2-3 (5),
|
|
phase3-1 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase/s associated with this outlet.
|
|
|
|
For single phase devices, this object will always
|
|
return phase1(1).
|
|
|
|
For 3-phase devices, this object will return phase1 (1),
|
|
phase2 (2), or phase3 (3) for outlets tied to a single
|
|
phase. For outlets tied to two phases, this object will
|
|
return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
|
|
phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
|
|
::= { ePDUOutletConfigEntry 3 }
|
|
|
|
ePDUOutletConfigPowerOnTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) the outlet will delay
|
|
powering on at coldstart or when a command that requires
|
|
a turn-on delay is issued.
|
|
|
|
Allowed values are:
|
|
|
|
-1 - never power on.
|
|
0 - power on immediately.
|
|
1 to 7200 - power on up to 7200 seconds after being
|
|
commanded."
|
|
::= { ePDUOutletConfigEntry 4 }
|
|
|
|
ePDUOutletConfigPowerOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) the outlet will delay
|
|
powering off when a command that requires
|
|
a turn-off delay is issued.
|
|
|
|
Allowed values are:
|
|
|
|
-1 - never power off.
|
|
0 - power off immediately.
|
|
1 to 7200 - power off up to 7200 seconds after being
|
|
commanded."
|
|
::= { ePDUOutletConfigEntry 5 }
|
|
|
|
ePDUOutletConfigRebootDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"During a reboot sequence, power is turned off and then
|
|
back on. This OID defines the amount of time to wait,
|
|
in seconds, after turning the power off, at the start
|
|
of the sequence, before turning power back on, at the
|
|
end of the reboot sequence.
|
|
|
|
Allowed range is any value between 5 and 60 seconds (1 minute)."
|
|
::= { ePDUOutletConfigEntry 6 }
|
|
|
|
ePDUOutletConfigOutletBank OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank associated with this outlet."
|
|
::= { ePDUOutletConfigEntry 7 }
|
|
|
|
|
|
-- Monitored Outlets table
|
|
|
|
ePDUOutletConfigMonitoredTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Outlet Config Monitored Table"
|
|
::= { ePDUOutletConfig 2 }
|
|
|
|
|
|
ePDUOutletConfigMonitoredTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletConfigMonitoredEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting/setting of outlet thresholds of an Outlet Monitored Rack PDU."
|
|
::= { ePDUOutletConfig 3 }
|
|
|
|
ePDUOutletConfigMonitoredEntry OBJECT-TYPE
|
|
SYNTAX OutletConfigMonitoredEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to Monitored Outlet entries"
|
|
INDEX { ePDUOutletConfigMonitoredIndex }
|
|
::= { ePDUOutletConfigMonitoredTable 1 }
|
|
|
|
OutletConfigMonitoredEntry ::=
|
|
SEQUENCE {
|
|
ePDUOutletConfigMonitoredIndex INTEGER,
|
|
ePDUOutletConfigMonitoredName DisplayString,
|
|
ePDUOutletConfigMonitoredNumber INTEGER,
|
|
ePDUOutletConfigMonitoredLowLoadThreshold INTEGER,
|
|
ePDUOutletConfigMonitoredNearOverloadThreshold INTEGER,
|
|
ePDUOutletConfigMonitoredOverloadThreshold INTEGER,
|
|
ePDUOutletConfigMonitoredPeakLoadReset INTEGER,
|
|
ePDUOutletConfigMonitoredEnergyReset INTEGER
|
|
}
|
|
|
|
ePDUOutletConfigMonitoredIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the RACK PDU Phase entry."
|
|
::= { ePDUOutletConfigMonitoredEntry 1 }
|
|
|
|
ePDUOutletConfigMonitoredName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the Monitored Outlet. The maximum string size is device dependent.
|
|
An error will be returned if the set request exceeds the max size."
|
|
::= { ePDUOutletConfigMonitoredEntry 2 }
|
|
|
|
ePDUOutletConfigMonitoredNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet number of an Outlet Monitored RACK PDU."
|
|
::= { ePDUOutletConfigMonitoredEntry 3 }
|
|
|
|
|
|
ePDUOutletConfigMonitoredLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing a low consumption condition. It is
|
|
represented in watts. A warning will be issued when
|
|
the load is less than the threshold value.
|
|
|
|
A threshold value of 0 effectively disables this
|
|
warning.
|
|
|
|
Maximum value must be less than the value returned
|
|
by the ePDUOutletConfigMonitoredNearOverloadThreshold OID.
|
|
|
|
0 will be returned if the unit is not Outlet Monitored Rack PDU."
|
|
::= { ePDUOutletConfigMonitoredEntry 4 }
|
|
|
|
ePDUOutletConfigMonitoredNearOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing an overload condition. It is
|
|
represented in watts. A warning
|
|
will be issued when the load is greater than or equal
|
|
to the threshold value.
|
|
|
|
Minimum value must be greater than the value returned by
|
|
the ePDUOutletConfigMonitoredLowLoadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the ePDUOutletConfigMonitoredOverloadThreshold OID.
|
|
|
|
0 will be returned if the unit is not Outlet Monitored Rack PDU."
|
|
::= { ePDUOutletConfigMonitoredEntry 5 }
|
|
|
|
ePDUOutletConfigMonitoredOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load has entered an overload condition. It is
|
|
represented in watts. A warning
|
|
will be issued when the load is greater than or equal
|
|
to the threshold value.
|
|
|
|
Minimum value must be greater than or equal to the value
|
|
returned by the ePDUOutletConfigMonitoredNearOverloadThreshold OID.
|
|
|
|
Maximum value must be less than or equal to the value
|
|
returned by the ePDULoadDevMaxOutletLoad OID.
|
|
|
|
0 will be returned if the unit is not Outlet Monitored Rack PDU."
|
|
::= { ePDUOutletConfigMonitoredEntry 6 }
|
|
|
|
ePDUOutletConfigMonitoredPeakLoadReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction (1),
|
|
reset (2),
|
|
notSupport (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the existing peak power value
|
|
to be replaced by the current load power value.
|
|
|
|
Getting this oid will do nothing and return noAction (1) if the PDU
|
|
support this feature, return notSupport (3) if the PDU do not support
|
|
this feature. "
|
|
::= { ePDUOutletConfigMonitoredEntry 7 }
|
|
|
|
ePDUOutletConfigMonitoredEnergyReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction (1),
|
|
reset (2),
|
|
notSupport (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the device energy meter value
|
|
to be reset to zero.
|
|
|
|
Getting this oid will do nothing and return noAction (1) if the PDU
|
|
support this feature, return notSupport (3) if the PDU do not support
|
|
this feature. "
|
|
::= { ePDUOutletConfigMonitoredEntry 8 }
|
|
|
|
|
|
-- the ePDUOutletStatus group
|
|
|
|
ePDUOutletStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDUOutletStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of individual outlets. The number of
|
|
entries is contained in the ePDUOutletDevNumCntrlOutlets OID."
|
|
::= { ePDUOutletStatus 1 }
|
|
|
|
ePDUOutletStatusEntry OBJECT-TYPE
|
|
SYNTAX EPDUOutletStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet to gather status from."
|
|
INDEX { ePDUOutletStatusIndex}
|
|
::= { ePDUOutletStatusTable 1 }
|
|
|
|
EPDUOutletStatusEntry ::=
|
|
SEQUENCE {
|
|
ePDUOutletStatusIndex INTEGER,
|
|
ePDUOutletStatusOutletName DisplayString,
|
|
ePDUOutletStatusOutletPhase INTEGER,
|
|
ePDUOutletStatusOutletState INTEGER,
|
|
ePDUOutletStatusCommandPending INTEGER,
|
|
ePDUOutletStatusOutletBank INTEGER,
|
|
ePDUOutletStatusLoad Gauge,
|
|
ePDUOutletStatusActivePower Gauge,
|
|
ePDUOutletStatusAlarm INTEGER,
|
|
ePDUOutletStatusPeakPower Gauge,
|
|
ePDUOutletStatusPeakPowerTime DisplayString,
|
|
ePDUOutletStatusPeakPowerStart DisplayString,
|
|
ePDUOutletStatusEnergy Gauge,
|
|
ePDUOutletStatusEnergyStartTime DisplayString
|
|
}
|
|
|
|
ePDUOutletStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { ePDUOutletStatusEntry 1 }
|
|
|
|
ePDUOutletStatusOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum string size is device dependent.
|
|
This OID is provided for informational purposes only."
|
|
::= { ePDUOutletStatusEntry 2 }
|
|
|
|
ePDUOutletStatusOutletPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3),
|
|
phase1-2 (4),
|
|
phase2-3 (5),
|
|
phase3-1 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase/s associated with this outlet.
|
|
|
|
For single phase devices, this object will always
|
|
return phase1(1).
|
|
|
|
For 3-phase devices, this object will return phase1 (1),
|
|
phase2 (2), or phase3 (3) for outlets tied to a single
|
|
phase. For outlets tied to two phases, this object will
|
|
return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
|
|
phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
|
|
::= { ePDUOutletStatusEntry 3 }
|
|
|
|
ePDUOutletStatusOutletState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletStatusOn (1),
|
|
outletStatusOff (2)
|
|
}
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the outletStatusOn (1) value will be returned.
|
|
If the outlet is off, the outletStatusOff (2) value will be
|
|
returned."
|
|
::= { ePDUOutletStatusEntry 4 }
|
|
|
|
ePDUOutletStatusCommandPending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletStatusCommandPending (1),
|
|
outletStatusNoCommandPending (2)
|
|
}
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the command pending
|
|
state of the outlet. If a command is pending on the
|
|
outlet, the outletStatusCommandPending (1) value
|
|
will be returned. If there is not a command pending
|
|
on the outlet, the outletStatusNoCommandPending (2)
|
|
will be returned."
|
|
::= { ePDUOutletStatusEntry 5 }
|
|
|
|
ePDUOutletStatusOutletBank OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank associated with this outlet."
|
|
::= { ePDUOutletStatusEntry 6 }
|
|
|
|
ePDUOutletStatusLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU
|
|
in tenths of Amps."
|
|
::= { ePDUOutletStatusEntry 7 }
|
|
|
|
ePDUOutletStatusActivePower OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU
|
|
in watts"
|
|
::= { ePDUOutletStatusEntry 8 }
|
|
|
|
ePDUOutletStatusAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noLoadAlarm (1),
|
|
underCurrentAlarm (2),
|
|
nearOverCurrentAlarm (3),
|
|
overCurrentAlarm (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the current outlet alarm"
|
|
::= { ePDUOutletStatusEntry 9 }
|
|
|
|
ePDUOutletStatusPeakPower OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak power consumption of the Rack PDU load in watts.
|
|
This value can be reset by setting the oid
|
|
ePDUOutletConfigMonitoredPeakLoadReset to reset (2)"
|
|
::= { ePDUOutletStatusEntry 10 }
|
|
|
|
ePDUOutletStatusPeakPowerTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Get this oid shows the date and time that peak power consumption occurred"
|
|
::= { ePDUOutletStatusEntry 11 }
|
|
|
|
ePDUOutletStatusPeakPowerStart OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Get this oid shows the date and time that peak power consumption started"
|
|
::= { ePDUOutletStatusEntry 12 }
|
|
|
|
ePDUOutletStatusEnergy OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Energy meter measuring Rack PDU load energy consumption
|
|
in tenths of kilowatt-hours. This value can be reset by setting
|
|
the oid ePDUOutletConfigMonitoredEnergyReset to reset (2)"
|
|
::= { ePDUOutletStatusEntry 13 }
|
|
|
|
ePDUOutletStatusEnergyStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time of the last device energy
|
|
meter reset"
|
|
::= { ePDUOutletStatusEntry 14 }
|
|
|
|
|
|
-- the ePDUOutletBank group
|
|
|
|
ePDUOutletBankTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for management of outlets on a per bank basis."
|
|
::= { ePDUOutletBank 1 }
|
|
|
|
ePDUOutletBankEntry OBJECT-TYPE
|
|
SYNTAX OutletBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank to manage."
|
|
INDEX { ePDUOutletBankIndex}
|
|
::= { ePDUOutletBankTable 1 }
|
|
|
|
OutletBankEntry ::=
|
|
SEQUENCE {
|
|
ePDUOutletBankIndex INTEGER,
|
|
ePDUOutletBankOverloadRestriction INTEGER
|
|
}
|
|
|
|
ePDUOutletBankIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Switched Rack PDU bank entry."
|
|
::= { ePDUOutletBankEntry 1 }
|
|
|
|
ePDUOutletBankOverloadRestriction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysAllowTurnON (1),
|
|
restrictOnNearOverload (2),
|
|
restrictOnOverload (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID controls the behavior of a Switched Rack PDU
|
|
bank when an overload condition is possible and
|
|
additional outlets are requested to be turned on.
|
|
|
|
Setting this OID to alwaysAllowTurnON (1) will always allow
|
|
the outlets on the corresponding bank to turn on.
|
|
|
|
Setting this OID to restrictOnNearOverload (2) will not allow
|
|
outlets on the corresponding bank to turn on if the
|
|
ePDULoadBankConfigNearOverloadThreshold OID is exceeded.
|
|
|
|
Setting this OID to restrictOnOverload (3) will not allow
|
|
outlets on the corresponding bank to turn on if the
|
|
ePDULoadBankConfigOverloadThreshold OID is exceeded."
|
|
::= { ePDUOutletBankEntry 2 }
|
|
|
|
|
|
-- the ePDUPowerSupplyDevice group
|
|
|
|
ePDUPowerSupply1Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerSupplyOneOk (1),
|
|
powerSupplyOneFailed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return powerSupply1Ok(1) if power
|
|
supply 1 is functioning normally. If not functioning normally,
|
|
this OID will return powerSupply1Failed(2)."
|
|
::= { ePDUPowerSupplyDevice 1 }
|
|
|
|
ePDUPowerSupply2Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerSupplyTwoOk (1),
|
|
powerSupplyTwoFailed (2),
|
|
powerSupplyTwoNotPresent (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return powerSupply2Ok(1) if power
|
|
supply 2 is functioning normally. If not functioning normally,
|
|
this OID will return powerSupply2Failed(2).
|
|
|
|
Metered Rack PDUs do not have a redundant powersupply."
|
|
|
|
::= { ePDUPowerSupplyDevice 2 }
|
|
|
|
ePDUPowerSupplyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allAvailablePowerSuppliesOK (1),
|
|
powerSupplyOneFailed (2),
|
|
powerSupplyTwoFailed (3),
|
|
powerSupplyOneandTwoFailed (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return powerSupply Alarm"
|
|
::= { ePDUPowerSupplyDevice 3 }
|
|
|
|
|
|
-- the ePDUStatus group
|
|
|
|
ePDUStatusBankTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Status Bank Table"
|
|
::= { ePDUStatus 1 }
|
|
|
|
|
|
ePDUStatusBankTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of each Rack PDU Bank"
|
|
::= { ePDUStatus 2 }
|
|
|
|
ePDUStatusBankEntry OBJECT-TYPE
|
|
SYNTAX BankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to Bank entries"
|
|
INDEX { ePDUStatusBankIndex }
|
|
::= { ePDUStatusBankTable 1 }
|
|
|
|
BankEntry ::=
|
|
SEQUENCE {
|
|
ePDUStatusBankIndex INTEGER,
|
|
ePDUStatusBankNumber INTEGER,
|
|
ePDUStatusBankState INTEGER
|
|
}
|
|
|
|
ePDUStatusBankIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the RACK PDU Bank entry."
|
|
::= { ePDUStatusBankEntry 1 }
|
|
|
|
ePDUStatusBankNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bank number."
|
|
::= { ePDUStatusBankEntry 2 }
|
|
|
|
ePDUStatusBankState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bankLoadNormal (1),
|
|
bankLoadLow (2),
|
|
bankLoadNearOverload (3),
|
|
bankLoadOverload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bank load state.
|
|
|
|
bankLoadNormal(1) indicates that the bank is
|
|
operating properly within the ePDULoadBankConfigLowLoadThreshold
|
|
and ePDULoadBankConfigNearOverloadThreshold OID values.
|
|
|
|
bankLoadLow(2) indicates that the bank load has
|
|
dropped below the ePDULoadBankConfigLowLoadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
bankLoadNearOverload(3) indicates that the bank load
|
|
is greater than or equal to the
|
|
ePDULoadBankConfigNearOverloadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
bankLoadOverload(4) indicates that the bank load is
|
|
greater than or equal to the ePDULoadBankConfigOverloadThreshold
|
|
OID value.
|
|
An SNMP trap will occur when this state is entered or cleared."
|
|
::= { ePDUStatusBankEntry 3 }
|
|
|
|
-- Phase status table
|
|
|
|
ePDUStatusPhaseTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Status Phase Table"
|
|
::= { ePDUStatus 3 }
|
|
|
|
|
|
ePDUStatusPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of each Rack PDU Phase"
|
|
::= { ePDUStatus 4 }
|
|
|
|
ePDUStatusPhaseEntry OBJECT-TYPE
|
|
SYNTAX PhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to Phase entries"
|
|
INDEX { ePDUStatusPhaseIndex }
|
|
::= { ePDUStatusPhaseTable 1 }
|
|
|
|
PhaseEntry ::=
|
|
SEQUENCE {
|
|
ePDUStatusPhaseIndex INTEGER,
|
|
ePDUStatusPhaseNumber INTEGER,
|
|
ePDUStatusPhaseState INTEGER
|
|
}
|
|
|
|
ePDUStatusPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the RACK PDU Phase entry."
|
|
::= { ePDUStatusPhaseEntry 1 }
|
|
|
|
ePDUStatusPhaseNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase number."
|
|
::= { ePDUStatusPhaseEntry 2 }
|
|
|
|
ePDUStatusPhaseState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phaseLoadNormal (1),
|
|
phaseLoadLow (2),
|
|
phaseLoadNearOverload (3),
|
|
phaseLoadOverload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Phase load state.
|
|
|
|
phaseLoadNormal(1) indicates that the Phase is
|
|
operating properly within the ePDULoadPhaseConfigLowLoadThreshold
|
|
and ePDULoadPhaseConfigNearOverloadThreshold OID values.
|
|
|
|
phaseLoadLow(2) indicates that the Phase load has
|
|
dropped below the ePDULoadPhaseConfigLowLoadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
phaseLoadNearOverload(3) indicates that the Phase load
|
|
is greater than or equal to the
|
|
ePDULoadPhaseConfigNearOverloadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
phaseLoadOverload(4) indicates that the Phase load is
|
|
greater than or equal to the ePDULoadPhaseConfigOverloadThreshold
|
|
OID value.
|
|
An SNMP trap will occur when this state is entered or cleared."
|
|
::= { ePDUStatusPhaseEntry 3 }
|
|
|
|
|
|
-- Outlet status table
|
|
|
|
ePDUStatusOutletTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Status Outlet Table"
|
|
::= { ePDUStatus 5 }
|
|
|
|
|
|
ePDUStatusOutletTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU."
|
|
::= { ePDUStatus 6 }
|
|
|
|
ePDUStatusOutletEntry OBJECT-TYPE
|
|
SYNTAX OutletEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to Outlet entries"
|
|
INDEX { ePDUStatusOutletIndex }
|
|
::= { ePDUStatusOutletTable 1 }
|
|
|
|
OutletEntry ::=
|
|
SEQUENCE {
|
|
ePDUStatusOutletIndex INTEGER,
|
|
ePDUStatusOutletNumber INTEGER,
|
|
ePDUStatusOutletState INTEGER
|
|
}
|
|
|
|
ePDUStatusOutletIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the RACK PDU Outlet entry."
|
|
::= { ePDUStatusOutletEntry 1 }
|
|
|
|
ePDUStatusOutletNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Outlet number."
|
|
::= { ePDUStatusOutletEntry 2 }
|
|
|
|
ePDUStatusOutletState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletLoadNormal (1),
|
|
outletLoadLow (2),
|
|
outletLoadNearOverload (3),
|
|
outletLoadOverload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Outlet load state.
|
|
|
|
outletLoadNormal(1) indicates that the Outlet is
|
|
operating properly within the ePDUOutletConfigMonitoredLowLoadThreshold
|
|
and ePDUOutletConfigMonitoredNearOverloadThreshold OID values.
|
|
|
|
outletLoadLow(2) indicates that the Outlet load has
|
|
dropped below the ePDUOutletConfigMonitoredLowLoadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
outletLoadNearOverload(3) indicates that the Outlet load
|
|
is greater than or equal to the
|
|
ePDUOutletConfigMonitoredNearOverloadThreshold OID value.
|
|
An SNMP trap will occur when this state is entered or cleared.
|
|
|
|
outletLoadOverload(4) indicates that the Outlet load is
|
|
greater than or equal to the ePDUOutletConfigMonitoredOverloadThreshold
|
|
OID value.
|
|
An SNMP trap will occur when this state is entered or cleared."
|
|
::= { ePDUStatusOutletEntry 3 }
|
|
|
|
ePDUStatusInputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input voltage in 0.1 Volt."
|
|
::= { ePDUStatus 7 }
|
|
|
|
ePDUStatusInputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input frequency in 0.1 Hertz."
|
|
::= { ePDUStatus 8 }
|
|
|
|
-- environment Sensor Group
|
|
|
|
-- the envirIdent group
|
|
|
|
envirIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the environment sensor.
|
|
The maximum string size is device dependent."
|
|
::= { envirIdent 1 }
|
|
|
|
envirIdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the environment sensor.
|
|
The maximum string size is device dependent."
|
|
::= { envirIdent 2 }
|
|
|
|
-- the envirTemp group
|
|
|
|
envirTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The environment temperature expressed in 1/10 Fahrenheit"
|
|
::= { envirTemp 1 }
|
|
|
|
envirTempHighThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature threshold of the environment sensor.
|
|
The value expressed in Fahrenheit."
|
|
::= { envirTemp 2 }
|
|
|
|
envirTempLowThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature threshold of the environment sensor.
|
|
The value expressed in Fahrenheit."
|
|
::= { envirTemp 3 }
|
|
|
|
envirTempRateOfChange OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rate of change of the temperature.
|
|
The value expressed in Fahrenheit per 5 minute."
|
|
::= { envirTemp 4 }
|
|
|
|
envirTempHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees beyond the temperature thresholds
|
|
at which an active temperature alarm will be cleared.
|
|
This configuration setting applies to all temperature
|
|
thresholds.
|
|
Units are displayed in Fahrenheit."
|
|
::= { envirTemp 5 }
|
|
|
|
envirTemperatureCelsius OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The environment temperature expressed in 1/10 Celsius"
|
|
::= { envirTemp 6 }
|
|
|
|
envirTempCelsiusHighThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high temperature threshold of the environment sensor.
|
|
The value expressed in Celsius."
|
|
::= { envirTemp 7 }
|
|
|
|
envirTempCelsiusLowThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low temperature threshold of the environment sensor.
|
|
The value expressed in Celsius."
|
|
::= { envirTemp 8 }
|
|
|
|
envirTempCelsiusRateOfChange OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rate of change of the temperature.
|
|
The value expressed in Celsius per 5 minute."
|
|
::= { envirTemp 9 }
|
|
|
|
envirTempCelsiusHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees beyond the temperature thresholds
|
|
at which an active temperature alarm will be cleared.
|
|
This configuration setting applies to all temperature
|
|
thresholds.
|
|
Units are displayed in Celsius."
|
|
::= { envirTemp 10 }
|
|
|
|
-- the envirHumid group
|
|
|
|
envirHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The environment relative humidity expressed in persentage."
|
|
::= { envirHumid 1 }
|
|
|
|
envirHumidHighThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high relative humidity threshold of the environment sensor.
|
|
The value expressed in persentage."
|
|
::= { envirHumid 2 }
|
|
|
|
envirHumidLowThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low relative humidity threshold of the environment sensor.
|
|
The value expressed in persentage."
|
|
::= { envirHumid 3 }
|
|
|
|
envirHumidRateOfChange OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rate of change of the relative humidity.
|
|
The value expressed in persentage per 5 minute."
|
|
::= { envirHumid 4 }
|
|
|
|
envirHumidHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees beyond the relative humidity thresholds
|
|
at which an active relative humidity alarm will be cleared.
|
|
This configuration setting applies to all relative humidity
|
|
thresholds.
|
|
Units are displayed in persentage."
|
|
::= { envirHumid 5 }
|
|
|
|
envirContactTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of the contact in the environment sensor."
|
|
::= { envirContact 1 }
|
|
|
|
envirContactTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of information of each contact of the environment sensor."
|
|
::= { envirContact 2 }
|
|
|
|
envirContactEntry OBJECT-TYPE
|
|
SYNTAX ContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives access to contact entries"
|
|
INDEX { envirContactIndex }
|
|
::= { envirContactTable 1 }
|
|
|
|
ContactEntry ::=
|
|
SEQUENCE {
|
|
envirContactIndex INTEGER,
|
|
envirContactName DisplayString,
|
|
envirContactStatus INTEGER,
|
|
envirContactNormalState INTEGER
|
|
}
|
|
|
|
envirContactIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the contact of the environment sensor."
|
|
::= { envirContactEntry 1 }
|
|
|
|
envirContactName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting or setting the name of the contact of the environment sensor."
|
|
::= { envirContactEntry 2 }
|
|
|
|
envirContactStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
contactNormal (1),
|
|
contactAbnormal (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the Contact Status."
|
|
::= { envirContactEntry 3 }
|
|
|
|
envirContactNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normalOpen (1),
|
|
normalClose (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the contact normal state."
|
|
::= { envirContactEntry 4 }
|
|
|
|
-- ats Group
|
|
-- the atsIdent group
|
|
atsIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the ATS.
|
|
The maximum string size is device dependent."
|
|
::= { atsIdent 1 }
|
|
|
|
atsIdentModelName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string identifying the model name of the Automatic Transfer Switch.
|
|
This value is set at the factory."
|
|
::= { atsIdent 2 }
|
|
|
|
atsIdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the Automatic Transfer Switch.
|
|
This value is set at the factory."
|
|
::= { atsIdent 3 }
|
|
|
|
atsIdentFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string identifying the Automatic Transfer Switch
|
|
firmware revision."
|
|
::= { atsIdent 4 }
|
|
|
|
atsIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string identifying the serial number of
|
|
the Automatic Transfer Switch. This value is set at the factory."
|
|
::= { atsIdent 5 }
|
|
|
|
atsIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the Automatic Transfer Switch was manufactured in mm/dd/yyyy format.
|
|
This value is set at the factory. "
|
|
::= { atsIdent 6 }
|
|
|
|
atsIdentDeviceRatingVoltage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string identifing the Automatic Transfer Switch rating voltage."
|
|
::= { atsIdent 7 }
|
|
|
|
atsIdentDeviceRatingCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives the device rating current in Amps"
|
|
::= { atsIdent 8 }
|
|
|
|
atsIdentDeviceOutletNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This gives the outlet number of the device"
|
|
::= { atsIdent 9 }
|
|
|
|
atsIdentAgentModelName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string identifying the model name of the Agent."
|
|
::= { atsIdent 10 }
|
|
|
|
atsIdentAgentHardwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision of the Agent."
|
|
::= { atsIdent 11 }
|
|
|
|
atsIdentAgentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string identifying the Agent firmware revision."
|
|
::= { atsIdent 12 }
|
|
|
|
atsIdentAgentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string identifying the serial number of the Agent."
|
|
::= { atsIdent 13 }
|
|
|
|
-- the atsStatus group
|
|
-- the atsStatusDevice group in atsStatus group
|
|
atsStatusCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
atsNeverDiscovered (1),
|
|
atsCommEstablished (2),
|
|
atsCommLost (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the current communication status
|
|
between the Automatic Transfer Switch and the Agent. "
|
|
::= { atsStatusDevice 1 }
|
|
|
|
atsStatusSelectedSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sourceA (1),
|
|
sourceB (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the current source of power. "
|
|
::= { atsStatusDevice 2 }
|
|
|
|
atsStatusRedundancyState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
atsRedundancyLost (1),
|
|
atsFullyRedundant (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the current redundancy state of the ATS.
|
|
atsRedundancyLost(1) indicates that the ATS is unable to
|
|
switch over to the alternate power source if the current source fails.
|
|
atsFullyRedundant(2) indicates that the ATS will switch over to
|
|
the alternate power source if the current source fails."
|
|
::= { atsStatusDevice 3 }
|
|
|
|
atsStatusPhaseSyncStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inSync (1),
|
|
outOfSync (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the status of the phase sync."
|
|
::= { atsStatusDevice 4 }
|
|
|
|
atsStatusDevSourceRelayStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sourceRelayNormal (1),
|
|
sourceRelayFail (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the status of the source relay."
|
|
::= { atsStatusDevice 5 }
|
|
|
|
atsStatusDevInRelayStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inputRelayNormal (1),
|
|
inputRelayFail (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the status of the input relay."
|
|
::= { atsStatusDevice 6 }
|
|
|
|
atsStatusDevOutRelayStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outputRelayNormal (1),
|
|
outputRelayFail (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the status of the Output relay."
|
|
::= { atsStatusDevice 7 }
|
|
|
|
atsStatusDevLCDCommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lcdCommNormal (1),
|
|
lcdCommFail (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the communication status of the LCD."
|
|
::= { atsStatusDevice 8 }
|
|
|
|
atsStatusDevDB9CommStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
db9CommNormal (1),
|
|
db9CommFail (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the communication status of the DB9."
|
|
::= { atsStatusDevice 9 }
|
|
|
|
-- the atsStatusPowerSupplyTable in atsStatusDevice group
|
|
atsStatusPowerSupplyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtsStatusPowerSupplyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of power supply table entries."
|
|
::= { atsStatusDevice 10 }
|
|
|
|
atsStatusPowerSupplyEntry OBJECT-TYPE
|
|
SYNTAX AtsStatusPowerSupplyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing power supply information applicable to a
|
|
particular input."
|
|
|
|
INDEX { atsStatusPowerSupplyTableIndex }
|
|
::= { atsStatusPowerSupplyTable 1 }
|
|
|
|
AtsStatusPowerSupplyEntry ::= SEQUENCE {
|
|
atsStatusPowerSupplyTableIndex INTEGER,
|
|
atsStatusPowerSupplyInputSource INTEGER,
|
|
atsStatusPowerSupply12VStatus INTEGER,
|
|
atsStatusPowerSupply5VStatus INTEGER,
|
|
atsStatusPowerSupply3p3VStatus INTEGER
|
|
}
|
|
|
|
atsStatusPowerSupplyTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input identifier."
|
|
::= { atsStatusPowerSupplyEntry 1 }
|
|
|
|
atsStatusPowerSupplyInputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sourceA (1),
|
|
sourceB (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input source to the power supply."
|
|
::= { atsStatusPowerSupplyEntry 2 }
|
|
|
|
atsStatusPowerSupply12VStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerSupplyOK (1),
|
|
powerSupplyFailure (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the status of the power supply A 12V in system."
|
|
::= { atsStatusPowerSupplyEntry 3 }
|
|
|
|
atsStatusPowerSupply5VStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerSupplyOK (1),
|
|
powerSupplyFailure (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the status of the power supply A 5V in system."
|
|
::= { atsStatusPowerSupplyEntry 4 }
|
|
|
|
atsStatusPowerSupply3p3VStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerSupplyOK (1),
|
|
powerSupplyFailure (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the status of the power supply A 3.3V in system."
|
|
::= { atsStatusPowerSupplyEntry 5 }
|
|
|
|
-- the atsStatusInput group in atsStatus group
|
|
atsStatusInputNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input feeds to this device.
|
|
This variable indicates the number of rows in the
|
|
status input table."
|
|
::= { atsStatusInput 1 }
|
|
|
|
-- the atsStatusInputTable in atsStatusInput group
|
|
atsStatusInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtsStatusInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of atsNumInputs."
|
|
::= { atsStatusInput 2 }
|
|
|
|
atsStatusInputEntry OBJECT-TYPE
|
|
SYNTAX AtsStatusInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input."
|
|
|
|
INDEX { atsStatusInputTableIndex }
|
|
::= { atsStatusInputTable 1 }
|
|
|
|
AtsStatusInputEntry ::= SEQUENCE {
|
|
atsStatusInputTableIndex INTEGER,
|
|
atsStatusInputName DisplayString,
|
|
atsStatusNumInputPhase INTEGER,
|
|
atsStatusInputVoltageOrientation INTEGER,
|
|
atsStatusInputVoltage INTEGER,
|
|
atsStatusInputFrequency INTEGER,
|
|
atsStatusInputVolState INTEGER,
|
|
atsStatusInputFreqState INTEGER
|
|
}
|
|
|
|
atsStatusInputTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input identifier."
|
|
::= { atsStatusInputEntry 1 }
|
|
|
|
atsStatusInputName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A name given to a particular input."
|
|
::= { atsStatusInputEntry 2 }
|
|
|
|
atsStatusNumInputPhase OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input phases utilized in this device.
|
|
The sum of all the atsStatusNumInputPhase variable
|
|
indicates the number of rows in the status input
|
|
phase table."
|
|
::= { atsStatusInputEntry 3 }
|
|
|
|
atsStatusInputVoltageOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
singlePhase (2),
|
|
splitPhase (3),
|
|
threePhasePhaseToNeutral (4),
|
|
threePhasePhaseToPhase (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input voltage orientation:
|
|
1: unknown for this Source
|
|
2: singlePhase - phase 1 voltage is between Phase 1
|
|
and Neutral.
|
|
3: splitPhase - phase 1 voltage is between Phase 1 and
|
|
Neutral; phase 2 voltage is between Phase 2 and Neutral;
|
|
phase 3 voltage is between Phase 1 and Phase 2.
|
|
4: threePhasePhaseToNeutral - phase 1 voltage is between
|
|
Phase 1 and Neutral; phase 2 voltage is between Phase 2
|
|
and Neutral; phase 3 voltage is between Phase 3 and
|
|
Neutral.
|
|
5: threePhasePhaseToPhase - phase 1 voltage is between
|
|
Phase 1 and Phase 2; phase 2 voltage is between Phase 2
|
|
and Phase 3; phase 3 voltage is between Phase 3 and
|
|
Phase 1."
|
|
::= { atsStatusInputEntry 4 }
|
|
|
|
atsStatusInputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input voltage in 0.1 Volt."
|
|
::= { atsStatusInputEntry 5 }
|
|
|
|
atsStatusInputFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input frequency in 0.1 Hertz."
|
|
::= { atsStatusInputEntry 6 }
|
|
|
|
atsStatusInputVolState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
overVoltage (2),
|
|
underVoltage (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input voltage status."
|
|
::= { atsStatusInputEntry 7 }
|
|
|
|
atsStatusInputFreqState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
overFrequency (2),
|
|
underFrequency (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input frequency status."
|
|
::= { atsStatusInputEntry 8 }
|
|
|
|
-- the atsStatusInputPhaseTable in atsStatusInput group
|
|
atsStatusInputPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtsStatusInputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the sum of the atsNumInputPhases."
|
|
::= { atsStatusInput 3 }
|
|
|
|
atsStatusInputPhaseEntry OBJECT-TYPE
|
|
SYNTAX AtsStatusInputPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input phase."
|
|
|
|
INDEX { atsStatusInputPhaseTableIndex, atsStatusInputPhaseIndex }
|
|
::= { atsStatusInputPhaseTable 1 }
|
|
|
|
AtsStatusInputPhaseEntry ::= SEQUENCE {
|
|
atsStatusInputPhaseTableIndex INTEGER,
|
|
atsStatusInputPhaseIndex INTEGER,
|
|
atsStatusInputPhaseVoltage INTEGER,
|
|
atsStatusInputPhaseCurrent INTEGER,
|
|
atsStatusInputPhasePower INTEGER
|
|
}
|
|
|
|
atsStatusInputPhaseTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input identifier."
|
|
::= { atsStatusInputPhaseEntry 1 }
|
|
|
|
atsStatusInputPhaseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input phase identifier."
|
|
::= { atsStatusInputPhaseEntry 2 }
|
|
|
|
atsStatusInputPhaseVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input voltage in VAC, or -1 if it's unsupported
|
|
by this Source."
|
|
::= { atsStatusInputPhaseEntry 3 }
|
|
|
|
atsStatusInputPhaseCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input current in amperes, or -1 if it's
|
|
unsupported by this Source."
|
|
::= { atsStatusInputPhaseEntry 4 }
|
|
|
|
atsStatusInputPhasePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The input power in Watts, or -1 if it's unsupported
|
|
by this Source."
|
|
::= { atsStatusInputPhaseEntry 5 }
|
|
|
|
-- the atsConfig group
|
|
atsConfigPreferredSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sourceA (1),
|
|
sourceB (2),
|
|
none (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the preferred source of power when both sources are OK."
|
|
::= { atsConfig 1 }
|
|
|
|
atsConfigNominalVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable returns the nominal voltage of the input."
|
|
::= { atsConfig 2 }
|
|
|
|
atsConfigVoltageSensitivity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
high (1),
|
|
medium (2),
|
|
low (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable defines the sensitivity to changes in voltage:
|
|
high(1) for best protection, low(3) for frequent small line
|
|
voltage changes."
|
|
::= { atsConfig 3 }
|
|
|
|
atsConfigTransferVoltageRange OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wide (1),
|
|
medium (2),
|
|
narrow (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable defines the range of acceptable voltage from a power source.
|
|
If the voltage measured from the selected input source is not within this
|
|
range, the Automatic Transfer Switch will switch over (transfer) to the
|
|
alternate power source."
|
|
::= { atsConfig 4 }
|
|
|
|
atsConfigNarrowRangeValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To configure the Narrow Range value of acceptable voltage
|
|
from a power source."
|
|
::= { atsConfig 5 }
|
|
|
|
atsConfigMediumRangeValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To configure the Medium Range value of acceptable voltage
|
|
from a power source."
|
|
::= { atsConfig 6 }
|
|
|
|
atsConfigWideRangeValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To configure the Wide Range value of acceptable voltage
|
|
from a power source."
|
|
::= { atsConfig 7 }
|
|
|
|
atsConfigFrequencyDeviation OBJECT-TYPE
|
|
SYNTAX INTEGER (1..3)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To configure the frequency deviation."
|
|
::= { atsConfig 8 }
|
|
|
|
atsConfigDevLCDOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) which LCD turn off automatically
|
|
after it remains idle for."
|
|
::= { atsConfig 9 }
|
|
|
|
-- the atsControl group
|
|
atsCtrlResetATS OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
rboot (2),
|
|
reset (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable will cause the Automatic Transfer Switch to
|
|
reboot or reset relative setting to default value."
|
|
::= { atsControl 1 }
|
|
|
|
atsCtrlClearEventCounts OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
clear (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this variable will clear all event counts in Automatic Transfer Switch.
|
|
Returns (-1) if unsupported."
|
|
::= { atsControl 2 }
|
|
|
|
-- the atsLoad group
|
|
-- the atsLoadDevice group in the atsLoad group
|
|
atsLoadDevPhaseTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Phase Table."
|
|
::= { atsLoadDevice 1 }
|
|
|
|
-- the atsLoadDevPhaseTable in atsLoadDevice group
|
|
atsLoadDevPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LoadDevPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the Phase Max Load in the ATS."
|
|
::= { atsLoadDevice 2 }
|
|
|
|
atsLoadDevPhaseEntry OBJECT-TYPE
|
|
SYNTAX LoadDevPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ATS Phases Access."
|
|
INDEX { atsLoadDevPhaseTableIndex}
|
|
::= { atsLoadDevPhaseTable 1 }
|
|
|
|
LoadDevPhaseEntry ::=
|
|
SEQUENCE {
|
|
atsLoadDevPhaseTableIndex INTEGER,
|
|
atsLoadDevPhase INTEGER,
|
|
atsLoadDevPhaseMaxLoad INTEGER
|
|
}
|
|
|
|
atsLoadDevPhaseTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to ATS phase entry."
|
|
::= { atsLoadDevPhaseEntry 1 }
|
|
|
|
atsLoadDevPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3),
|
|
phase1-2 (4),
|
|
phase2-3 (5),
|
|
phase3-1 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For single phase devices, this object will always
|
|
return phase1(1).
|
|
|
|
For 3-phase devices, this object will return phase1 (1),
|
|
phase2 (2), phase3 (3), phase1-2 (4) for phases 1 and 2,
|
|
phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for
|
|
phases 3 and 1."
|
|
::= { atsLoadDevPhaseEntry 2 }
|
|
|
|
atsLoadDevPhaseMaxLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the maximum rated power that each
|
|
phase of the ATS can provide. It is represented in Amps."
|
|
::= { atsLoadDevPhaseEntry 3 }
|
|
|
|
atsLoadDevBankTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Bank Table."
|
|
::= { atsLoadDevice 3 }
|
|
|
|
-- the atsLoadDevBankTable in atsLoadDevice group
|
|
atsLoadDevBankTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtsLoadDevBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the Bank Max Load in the ATS."
|
|
::= { atsLoadDevice 4 }
|
|
|
|
atsLoadDevBankEntry OBJECT-TYPE
|
|
SYNTAX AtsLoadDevBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ATS Banks Access."
|
|
INDEX { atsLoadDevBankTableIndex}
|
|
::= { atsLoadDevBankTable 1 }
|
|
|
|
AtsLoadDevBankEntry ::=
|
|
SEQUENCE {
|
|
atsLoadDevBankTableIndex INTEGER,
|
|
atsLoadDevBankMaxLoad INTEGER
|
|
}
|
|
|
|
atsLoadDevBankTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
total (1),
|
|
bank1 (2),
|
|
bank2 (3),
|
|
bank3 (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the ATS bank entry."
|
|
::= { atsLoadDevBankEntry 1 }
|
|
|
|
atsLoadDevBankMaxLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the maximum rated power
|
|
that each bank of the ATS can provide. It is
|
|
represented in Amps."
|
|
::= { atsLoadDevBankEntry 2 }
|
|
|
|
-- the atsLoadStatus group in the atsLoad group
|
|
atsLoadStatusPhaseTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Phase Table."
|
|
::= { atsLoadStatus 1 }
|
|
|
|
-- the atsLoadStatusPhaseTable in atsLoadStatus group
|
|
atsLoadStatusPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LoadStatusPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the Phase Load status in the ATS."
|
|
::= { atsLoadStatus 2 }
|
|
|
|
atsLoadStatusPhaseEntry OBJECT-TYPE
|
|
SYNTAX LoadStatusPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ATS Phases Access."
|
|
INDEX { atsLoadStatusPhaseTableIndex}
|
|
::= { atsLoadStatusPhaseTable 1 }
|
|
|
|
LoadStatusPhaseEntry ::=
|
|
SEQUENCE {
|
|
atsLoadStatusPhaseTableIndex INTEGER,
|
|
atsLoadStatusPhase INTEGER,
|
|
atsLoadStatusPhaseLoad INTEGER,
|
|
atsLoadStatusPhaseLoadState INTEGER,
|
|
atsLoadStatusPhasePower INTEGER
|
|
}
|
|
|
|
atsLoadStatusPhaseTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to ATS phase entry."
|
|
::= { atsLoadStatusPhaseEntry 1 }
|
|
|
|
atsLoadStatusPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3),
|
|
phase1-2 (4),
|
|
phase2-3 (5),
|
|
phase3-1 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For single phase devices, this object will always
|
|
return phase1(1).
|
|
|
|
For 3-phase devices, this object will return phase1 (1),
|
|
phase2 (2), phase3 (3), phase1-2 (4) for phases 1 and 2,
|
|
phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for
|
|
phases 3 and 1."
|
|
::= { atsLoadStatusPhaseEntry 2 }
|
|
|
|
atsLoadStatusPhaseLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output current in 0.1 amperes drawn
|
|
by the load on the ATS"
|
|
::= { atsLoadStatusPhaseEntry 3 }
|
|
|
|
atsLoadStatusPhaseLoadState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
lowLoad (2),
|
|
nearOverLoad (3),
|
|
overLoad (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase load state."
|
|
::= { atsLoadStatusPhaseEntry 4 }
|
|
|
|
atsLoadStatusPhasePower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output power in Watts."
|
|
::= { atsLoadStatusPhaseEntry 5 }
|
|
|
|
atsLoadStatusBankTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Bank Table."
|
|
::= { atsLoadStatus 3 }
|
|
|
|
-- the atsLoadStatusBankTable in atsLoadStatus group
|
|
atsLoadStatusBankTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LoadStatusBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting the Bank Load status in the ATS."
|
|
::= { atsLoadStatus 4 }
|
|
|
|
atsLoadStatusBankEntry OBJECT-TYPE
|
|
SYNTAX LoadStatusBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ATS Bank Access."
|
|
INDEX { atsLoadStatusBankTableIndex}
|
|
::= { atsLoadStatusBankTable 1 }
|
|
|
|
LoadStatusBankEntry ::=
|
|
SEQUENCE {
|
|
atsLoadStatusBankTableIndex INTEGER,
|
|
atsLoadStatusBankPhase INTEGER,
|
|
atsLoadStatusBankLoad INTEGER,
|
|
atsLoadStatusBankLoadState INTEGER,
|
|
atsLoadStatusBankPower INTEGER,
|
|
atsLoadStatusBankEnergy INTEGER,
|
|
atsLoadStatusBankStartTime INTEGER
|
|
}
|
|
|
|
atsLoadStatusBankTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
total (1),
|
|
bank1 (2),
|
|
bank2 (3),
|
|
bank3 (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to ATS bank entry."
|
|
::= { atsLoadStatusBankEntry 1 }
|
|
|
|
atsLoadStatusBankPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3),
|
|
phase1-2 (4),
|
|
phase2-3 (5),
|
|
phase3-1 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase number."
|
|
::= { atsLoadStatusBankEntry 2 }
|
|
|
|
atsLoadStatusBankLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output current in 0.1 amperes drawn
|
|
by the load on the ATS"
|
|
::= { atsLoadStatusBankEntry 3 }
|
|
|
|
atsLoadStatusBankLoadState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
lowLoad (2),
|
|
nearOverLoad (3),
|
|
overLoad (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the bank load state."
|
|
::= { atsLoadStatusBankEntry 4 }
|
|
|
|
atsLoadStatusBankPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The output power in Watts."
|
|
::= { atsLoadStatusBankEntry 5 }
|
|
|
|
atsLoadStatusBankEnergy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the phase/bank apparent power measured in 0.1 kilowatt-hours."
|
|
::= { atsLoadStatusBankEntry 6 }
|
|
|
|
atsLoadStatusBankStartTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the date and time of the last energy meter reset"
|
|
::= { atsLoadStatusBankEntry 7 }
|
|
|
|
-- the atsLoadConfig group in the atsLoad group
|
|
atsLoadCfgPhaseTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Phase Table."
|
|
::= { atsLoadConfig 1 }
|
|
|
|
-- the atsLoadCfgPhaseTable in atsLoadConfig group
|
|
atsLoadCfgPhaseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LoadCfgPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of each ATS phase."
|
|
::= { atsLoadConfig 2 }
|
|
|
|
atsLoadCfgPhaseEntry OBJECT-TYPE
|
|
SYNTAX LoadCfgPhaseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ATS phase to configure."
|
|
INDEX { atsLoadCfgPhaseTableIndex}
|
|
::= { atsLoadCfgPhaseTable 1 }
|
|
|
|
LoadCfgPhaseEntry ::=
|
|
SEQUENCE {
|
|
atsLoadCfgPhaseTableIndex INTEGER,
|
|
atsLoadCfgPhase INTEGER,
|
|
atsLoadCfgPhaseLowLoad INTEGER,
|
|
atsLoadCfgPhaseNearOverLoad INTEGER,
|
|
atsLoadCfgPhaseOverLoad INTEGER,
|
|
atsLoadCfgPhaseOutletRestriction INTEGER
|
|
}
|
|
|
|
atsLoadCfgPhaseTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the ATS phase entry."
|
|
::= { atsLoadCfgPhaseEntry 1 }
|
|
|
|
atsLoadCfgPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3),
|
|
phase1-2 (4),
|
|
phase2-3 (5),
|
|
phase3-1 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For single phase devices, this object will always
|
|
return phase1(1).
|
|
|
|
For 3-phase devices, this object will return phase1 (1),
|
|
phase2 (2), phase3 (3), phase1-2 (4) for phases 1 and 2,
|
|
phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for
|
|
phases 3 and 1."
|
|
::= { atsLoadCfgPhaseEntry 2 }
|
|
|
|
atsLoadCfgPhaseLowLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing a low consumption condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is less than the threshold value.
|
|
|
|
A threshold value of 0 Amps effectively disables this
|
|
warning."
|
|
::= { atsLoadCfgPhaseEntry 3 }
|
|
|
|
atsLoadCfgPhaseNearOverLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value."
|
|
::= { atsLoadCfgPhaseEntry 4 }
|
|
|
|
atsLoadCfgPhaseOverLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load has entered an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value."
|
|
::= { atsLoadCfgPhaseEntry 5}
|
|
|
|
atsLoadCfgPhaseOutletRestriction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysAllowTurnON (1),
|
|
restrictOnNearOverload (2),
|
|
restrictOnOverload (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID controls the behavior of a ATS phase when an overload
|
|
condition is possible and additional outlets are requested to be
|
|
turned on.
|
|
|
|
Setting this OID to alwaysAllowTurnON (1) will always allow
|
|
the outlets on the corresponding phase to turn on.
|
|
|
|
Setting this OID to restrictOnNearOverload (2) will not allow
|
|
outlets on the corresponding phase to turn on if the
|
|
ePDULoadConfigNearOverloadThreshold OID is exceeded.
|
|
|
|
Setting this OID to restrictOnOverload (3) will not allow
|
|
outlets on the corresponding phase to turn on if the
|
|
ePDULoadConfigOverloadThreshold OID is exceeded."
|
|
::= { atsLoadCfgPhaseEntry 6 }
|
|
|
|
atsLoadCfgBankTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Bank Table."
|
|
::= { atsLoadConfig 3 }
|
|
|
|
-- the atsLoadCfgBankTable in atsLoadConfig group
|
|
atsLoadCfgBankTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LoadCfgBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of each ATS bank."
|
|
::= { atsLoadConfig 4 }
|
|
|
|
atsLoadCfgBankEntry OBJECT-TYPE
|
|
SYNTAX LoadCfgBankEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ATS phase to configure."
|
|
INDEX { atsLoadCfgBankTableIndex}
|
|
::= { atsLoadCfgBankTable 1 }
|
|
|
|
LoadCfgBankEntry ::=
|
|
SEQUENCE {
|
|
atsLoadCfgBankTableIndex INTEGER,
|
|
atsLoadCfgBankLowLoad INTEGER,
|
|
atsLoadCfgBankNearOverLoad INTEGER,
|
|
atsLoadCfgBankOverLoad INTEGER,
|
|
atsLoadCfgBankOutletRestriction INTEGER
|
|
}
|
|
|
|
atsLoadCfgBankTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
total (1),
|
|
bank1 (2),
|
|
bank2 (3),
|
|
bank3 (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the ATS bank entry."
|
|
::= { atsLoadCfgBankEntry 1 }
|
|
|
|
atsLoadCfgBankLowLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing a low consumption condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is less than the threshold value.
|
|
|
|
A threshold value of 0 Amps effectively disables this
|
|
warning."
|
|
::= { atsLoadCfgBankEntry 2 }
|
|
|
|
atsLoadCfgBankNearOverLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load is nearing an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value."
|
|
::= { atsLoadCfgBankEntry 3 }
|
|
|
|
atsLoadCfgBankOverLoad OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A threshold that indicates the power consumption of
|
|
the load has entered an overload condition. It is
|
|
represented in Amps. A warning will be issued when the
|
|
load is greater than or equal to the threshold value."
|
|
::= { atsLoadCfgBankEntry 4 }
|
|
|
|
atsLoadCfgBankOutletRestriction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysAllowTurnON (1),
|
|
restrictOnNearOverload (2),
|
|
restrictOnOverload (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID controls the behavior of a ATS phase when an overload
|
|
condition is possible and additional outlets are requested to be
|
|
turned on.
|
|
|
|
Setting this OID to alwaysAllowTurnON (1) will always allow
|
|
the outlets on the corresponding phase to turn on.
|
|
|
|
Setting this OID to restrictOnNearOverload (2) will not allow
|
|
outlets on the corresponding phase to turn on if the
|
|
ePDULoadConfigNearOverloadThreshold OID is exceeded.
|
|
|
|
Setting this OID to restrictOnOverload (3) will not allow
|
|
outlets on the corresponding phase to turn on if the
|
|
ePDULoadConfigOverloadThreshold OID is exceeded."
|
|
::= { atsLoadCfgBankEntry 5 }
|
|
|
|
-- the atsOutlet group
|
|
-- the atsOutletDevice group in the atsOutlet group
|
|
atsOutletDevTotalOutletNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of outlets on the ATS."
|
|
::= { atsOutletDevice 1 }
|
|
|
|
atsOutletDevCtrlOutletNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of controlled outlets on the ATS."
|
|
::= { atsOutletDevice 2 }
|
|
|
|
atsOutletDevColdStartDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of delay, in seconds, between when
|
|
power is provided to the ATS and when the ATS
|
|
provides basic master power to the outlets.
|
|
|
|
Allowed values are:
|
|
|
|
-1 - never apply power automatically.
|
|
0 - apply power immediately.
|
|
1 to 300 - delay up to 300 seconds (5 minutes)."
|
|
::= { atsOutletDevice 3 }
|
|
|
|
atsOutletDevColdStartState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allOn (1),
|
|
previous (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ATS outlet state after coldstart.
|
|
Allowed values are:
|
|
1 - all outlets on after coldstart.
|
|
2 - outlet status same as previous state."
|
|
::= { atsOutletDevice 4 }
|
|
|
|
atsOutletDevLocalCtrl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To configure enable or disable outlet local control function."
|
|
::= { atsOutletDevice 5 }
|
|
|
|
atsOutletDevCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noCommandAll (1),
|
|
immediateAllOn (2),
|
|
immediateAllOff (3),
|
|
immediateAllReboot (4),
|
|
delayedAllOn (5),
|
|
delayedAllOff (6),
|
|
delayedAllReboot (7),
|
|
cancelAllPendingCommands (8)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to immediateAllOn (2) will turn all outlets
|
|
on immediately.
|
|
|
|
Setting this OID to immediateAllOff (3) will turn all outlets
|
|
off immediately.
|
|
|
|
Setting this OID to immediateAllReboot (4) will reboot all outlets
|
|
immediately.
|
|
|
|
Setting this OID to delayedAllOn (5) will turn all outlets on as
|
|
defined by each outlet's atsOutletCfgPowerOnTime OID value.
|
|
|
|
Setting this OID to delayedAllOff (6) will turn all outlets
|
|
off as defined by each outlet's atsOutletCfgPowerOffTime OID value.
|
|
|
|
Setting this OID to delayedAllReboot (7) will cause a
|
|
delayedAllOff command to be performed. Once all outlets are off,
|
|
the Switched Rack ATS will then delay the largest
|
|
atsOutletCfgRebootDuration OID time, and then perform a
|
|
delayedAllOn command.
|
|
|
|
Setting this OID to cancelAllPendingCommands (8) will cause all pending
|
|
commands on the Switched Rack ATS to be canceled.
|
|
|
|
Getting this OID will return the noCommandAll (1) value."
|
|
::= { atsOutletDevice 6 }
|
|
|
|
atsOutletStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the outlet status table."
|
|
::= { atsOutlet 2 }
|
|
|
|
-- the atsOutletStatusTable in atsOutlet group
|
|
atsOutletStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of individual outlets."
|
|
::= { atsOutlet 3 }
|
|
|
|
atsOutletStatusEntry OBJECT-TYPE
|
|
SYNTAX OutletStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet to gather status from."
|
|
INDEX { atsOutletStatusTableIndex}
|
|
::= { atsOutletStatusTable 1 }
|
|
|
|
OutletStatusEntry ::=
|
|
SEQUENCE {
|
|
atsOutletStatusTableIndex INTEGER,
|
|
atsOutletStatusOutletName DisplayString,
|
|
atsOutletStatusOutletState INTEGER,
|
|
atsOutletStatusOutletCmdPending INTEGER,
|
|
atsOutletStatusOutletPhase INTEGER,
|
|
atsOutletStatusOutletBank INTEGER
|
|
}
|
|
|
|
atsOutletStatusTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..19)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { atsOutletStatusEntry 1 }
|
|
|
|
atsOutletStatusOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum string size is device dependent.
|
|
This OID is provided for informational purposes only."
|
|
::= { atsOutletStatusEntry 2 }
|
|
|
|
atsOutletStatusOutletState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletStatusOn (1),
|
|
outletStatusOff (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the outletStatusOn (1) value will be returned.
|
|
If the outlet is off, the outletStatusOff (2) value will be
|
|
returned."
|
|
::= { atsOutletStatusEntry 3 }
|
|
|
|
atsOutletStatusOutletCmdPending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletStatusCommandPending (1),
|
|
outletStatusNoCommandPending (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the command pending
|
|
state of the outlet. If a command is pending on the
|
|
outlet, the outletStatusCommandPending (1) value
|
|
will be returned. If there is not a command pending
|
|
on the outlet, the outletStatusNoCommandPending (2)
|
|
will be returned."
|
|
::= { atsOutletStatusEntry 4 }
|
|
|
|
atsOutletStatusOutletPhase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phase1 (1),
|
|
phase2 (2),
|
|
phase3 (3),
|
|
phase1-2 (4),
|
|
phase2-3 (5),
|
|
phase3-1 (6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase/s associated with this outlet.
|
|
|
|
For single phase devices, this object will always
|
|
return phase1(1).
|
|
|
|
For 3-phase devices, this object will return phase1 (1),
|
|
phase2 (2), or phase3 (3) for outlets tied to a single
|
|
phase. For outlets tied to two phases, this object will
|
|
return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
|
|
phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
|
|
::= { atsOutletStatusEntry 5 }
|
|
|
|
atsOutletStatusOutletBank OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bank associated with this outlet."
|
|
::= { atsOutletStatusEntry 6 }
|
|
|
|
atsOutletCtrlTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the outlet control table."
|
|
::= { atsOutlet 4 }
|
|
|
|
-- the atsOutletCtrlTable in atsOutlet group
|
|
atsOutletCtrlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletCtrlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for control of the individual outlets."
|
|
::= { atsOutlet 5 }
|
|
|
|
atsOutletCtrlEntry OBJECT-TYPE
|
|
SYNTAX OutletCtrlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet to control."
|
|
INDEX { atsOutletCtrlTableIndex}
|
|
::= { atsOutletCtrlTable 1 }
|
|
|
|
OutletCtrlEntry ::=
|
|
SEQUENCE {
|
|
atsOutletCtrlTableIndex INTEGER,
|
|
atsOutletCtrlOutletName DisplayString,
|
|
atsOutletCtrlCommand INTEGER
|
|
}
|
|
|
|
atsOutletCtrlTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..19)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { atsOutletCtrlEntry 1 }
|
|
|
|
atsOutletCtrlOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum string size is device dependent.
|
|
An error will be returned if the set request exceeds the max size.
|
|
This OID is provided for informational purposes only."
|
|
::= { atsOutletCtrlEntry 2 }
|
|
|
|
atsOutletCtrlCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
immediateOn (2),
|
|
immediateOff (3),
|
|
immediateReboot (4),
|
|
delayedOn (5),
|
|
delayedOff (6),
|
|
delayedReboot (7),
|
|
cancelPendingCommand (8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the immediateOn (2) value will be returned.
|
|
If the outlet is off, the immediateOff (2) value will be
|
|
returned.
|
|
|
|
Setting this variable to immediateOn (2) will immediately turn
|
|
the outlet on.
|
|
|
|
Setting this variable to immediateOff (3) will immediately turn
|
|
the outlet off.
|
|
|
|
Setting this variable to immediateReboot (4) will immediately
|
|
reboot the outlet.
|
|
|
|
Setting this variable to delayedOn (5) will turn the outlet on
|
|
after the ePDUOutletConfigPowerOnTime OID time has elapsed.
|
|
|
|
Setting this variable to delayedOff (6) will turn the outlet off
|
|
after the ePDUOutletConfigPowerOffTime OID time has elapsed.
|
|
|
|
Setting this variable to delayedReboot (7) will cause the
|
|
ATS to perform a delayedOff command, wait the atsOutletCfgRebootDuration
|
|
OID time, and then perform a delayedOn command.
|
|
|
|
Setting this variable to cancelPendingCommand (8) will cause any
|
|
pending command to this outlet to be canceled."
|
|
::= { atsOutletCtrlEntry 3 }
|
|
|
|
atsOutletCfgTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the outlet config table."
|
|
::= { atsOutlet 6 }
|
|
|
|
-- the atsOutletCfgTable in atsOutlet group
|
|
atsOutletCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtsOutletConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for configuration of individual outlets."
|
|
::= { atsOutlet 7 }
|
|
|
|
atsOutletCfgEntry OBJECT-TYPE
|
|
SYNTAX AtsOutletConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outlet to configure."
|
|
INDEX { atsOutletCfgTableIndex}
|
|
::= { atsOutletCfgTable 1 }
|
|
|
|
AtsOutletConfigEntry ::=
|
|
SEQUENCE {
|
|
atsOutletCfgTableIndex INTEGER,
|
|
atsOutletCfgOutletName DisplayString,
|
|
atsOutletCfgPowerOnTime INTEGER,
|
|
atsOutletCfgPowerOffTime INTEGER,
|
|
atsOutletCfgRebootDuration INTEGER
|
|
}
|
|
|
|
atsOutletCfgTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..19)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the outlet entry."
|
|
::= { atsOutletCfgEntry 1 }
|
|
|
|
atsOutletCfgOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the outlet. The maximum string size is device dependent.
|
|
An error will be returned if the set request exceeds the max size."
|
|
::= { atsOutletCfgEntry 2 }
|
|
|
|
atsOutletCfgPowerOnTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) the outlet will delay
|
|
powering on at coldstart or when a command that requires
|
|
a turn-on delay is issued.
|
|
|
|
Allowed values are:
|
|
-1 - never power on.
|
|
0 - power on immediately.
|
|
1 to 7200 - power on up to 7200 seconds after being commanded."
|
|
::= { atsOutletCfgEntry 3 }
|
|
|
|
atsOutletCfgPowerOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) the outlet will delay
|
|
powering off when a command that requires
|
|
a turn-off delay is issued.
|
|
|
|
Allowed values are:
|
|
|
|
-1 - never power off.
|
|
0 - power off immediately.
|
|
1 to 7200 - power off up to 7200 seconds after being commanded."
|
|
::= { atsOutletCfgEntry 4 }
|
|
|
|
atsOutletCfgRebootDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"During a reboot sequence, power is turned off and then
|
|
back on. This OID defines the amount of time to wait,
|
|
in seconds, after turning the power off, at the start
|
|
of the sequence, before turning power back on, at the
|
|
end of the reboot sequence.
|
|
|
|
Allowed range is any value between 5 and 60 seconds (1 minute)."
|
|
::= { atsOutletCfgEntry 5 }
|
|
|
|
-- ePDU2 Group
|
|
-- Daisy Chain ePDU OID
|
|
ePDU2Role OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standalone(1),
|
|
host(2),
|
|
slave(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Get this oid shows the role the PDU played on Daisy Chain Group.
|
|
The PDU as a Host can access whole ePDU2 content, and the PDU be standalong
|
|
or a Slave can access itself instead."
|
|
::= { ePDU2 1 }
|
|
|
|
-- ePDU2Ident
|
|
ePDU2IdentTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PDU as a Host response total PDU ident number on daisy chain.
|
|
PDU as a Slave can only response 1."
|
|
::= { ePDU2Ident 1 }
|
|
|
|
ePDU2IdentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2IdentEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU identification information."
|
|
::= { ePDU2Ident 2 }
|
|
|
|
ePDU2IdentEntry OBJECT-TYPE
|
|
SYNTAX EPDU2IdentEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identification data from Rack PDU being queried."
|
|
INDEX { ePDU2IdentIndex }
|
|
::= { ePDU2IdentTable 1 }
|
|
|
|
EPDU2IdentEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2IdentIndex INTEGER,
|
|
ePDU2IdentModuleIndex INTEGER,
|
|
ePDU2IdentName DisplayString,
|
|
ePDU2IdentLocation DisplayString,
|
|
ePDU2IdentContact DisplayString,
|
|
ePDU2IdentHardwareRev DisplayString,
|
|
ePDU2IdentFirmwareRev DisplayString,
|
|
ePDU2IdentDateOfManufacture DisplayString,
|
|
ePDU2IdentModelName DisplayString,
|
|
ePDU2IdentSerialNumber DisplayString,
|
|
ePDU2IdentIndicator INTEGER
|
|
}
|
|
|
|
ePDU2IdentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU identification table entry."
|
|
::= { ePDU2IdentEntry 1 }
|
|
|
|
ePDU2IdentModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU identification table entry numeric ID."
|
|
::= { ePDU2IdentEntry 2 }
|
|
|
|
ePDU2IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the name of the Rack PDU."
|
|
::= { ePDU2IdentEntry 3 }
|
|
|
|
ePDU2IdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the location of the Rack PDU."
|
|
::= { ePDU2IdentEntry 4 }
|
|
|
|
ePDU2IdentContact OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the person to contact of the Rack PDU."
|
|
::= { ePDU2IdentEntry 5 }
|
|
|
|
ePDU2IdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU hardware version."
|
|
::= { ePDU2IdentEntry 6 }
|
|
|
|
ePDU2IdentFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU firmware version."
|
|
::= { ePDU2IdentEntry 7 }
|
|
|
|
ePDU2IdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date the Rack PDU was manufactured in mm/dd/yyyy format."
|
|
::= { ePDU2IdentEntry 8 }
|
|
|
|
ePDU2IdentModelName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU model number."
|
|
::= { ePDU2IdentEntry 9 }
|
|
|
|
ePDU2IdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU serial number."
|
|
::= { ePDU2IdentEntry 10 }
|
|
|
|
ePDU2IdentIndicator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTestIndicators(1),
|
|
testIndicators(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PDU will perform a panel indicator test when the variable
|
|
is set to testIndicators(2).
|
|
|
|
It is no effective to set this value to noTestIndicators(1)."
|
|
::= { ePDU2IdentEntry 11 }
|
|
|
|
-- ePDU2Device
|
|
ePDU2DeviceTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Host Rack PDU response total number of Rack PDUs on daisy chain.
|
|
Rack PDU as a Slave can only response 1."
|
|
::= { ePDU2Device 1 }
|
|
|
|
-- Device Config Table
|
|
ePDU2DeviceConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2DeviceConfigEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU configuration data."
|
|
::= { ePDU2Device 2 }
|
|
|
|
ePDU2DeviceConfigEntry OBJECT-TYPE
|
|
SYNTAX EPDU2DeviceConfigEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from Rack PDU being queried."
|
|
INDEX { ePDU2DeviceConfigIndex }
|
|
::= { ePDU2DeviceConfigTable 1 }
|
|
|
|
EPDU2DeviceConfigEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2DeviceConfigIndex INTEGER,
|
|
ePDU2DeviceConfigModuleIndex INTEGER,
|
|
ePDU2DeviceConfigName DisplayString,
|
|
ePDU2DeviceConfigLocation DisplayString,
|
|
ePDU2DeviceConfigContact DisplayString,
|
|
ePDU2DeviceConfigDisplayOrientation INTEGER,
|
|
ePDU2DeviceConfigColdstartDelay INTEGER,
|
|
ePDU2DeviceConfigCurrentLowLoadThreshold INTEGER,
|
|
ePDU2DeviceConfigCurrentNearOverloadThreshold INTEGER,
|
|
ePDU2DeviceConfigCurrentOverloadThreshold INTEGER,
|
|
ePDU2DeviceConfigPeakLoadReset INTEGER,
|
|
ePDU2DeviceConfigEnergyReset INTEGER,
|
|
ePDU2DeviceConfigPowerLowLoadThreshold INTEGER,
|
|
ePDU2DeviceConfigPowerNearOverloadThreshold INTEGER,
|
|
ePDU2DeviceConfigPowerOverloadThreshold INTEGER
|
|
}
|
|
|
|
ePDU2DeviceConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU table entry."
|
|
::= { ePDU2DeviceConfigEntry 1 }
|
|
|
|
ePDU2DeviceConfigModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= { ePDU2DeviceConfigEntry 2 }
|
|
|
|
ePDU2DeviceConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the name of Rack PDU."
|
|
::= { ePDU2DeviceConfigEntry 3 }
|
|
|
|
ePDU2DeviceConfigLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the location of the Rack PDU."
|
|
::= { ePDU2DeviceConfigEntry 4 }
|
|
|
|
ePDU2DeviceConfigContact OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the person to contact of the Rack PDU."
|
|
::= { ePDU2DeviceConfigEntry 5 }
|
|
|
|
ePDU2DeviceConfigDisplayOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
displayNormal (1),
|
|
displayReverse (2),
|
|
displayRotate90 (3),
|
|
displayRotate270 (4),
|
|
displayAuto (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the intended physical orientation of the Seven-Segment Display.
|
|
|
|
displayNormal(1) indicates Normal.
|
|
displayReverse(2)indicates Upside-Down.
|
|
displayRotate90(3) indicates rotate 90 degree.
|
|
displayRotate270(4) indicates rotate 270 degree.
|
|
displayAuto(5) indicates auto-detect and rotate."
|
|
::= { ePDU2DeviceConfigEntry 6 }
|
|
|
|
ePDU2DeviceConfigColdstartDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of delay, measured in seconds, between
|
|
when power is provided to the Rack PDU and when
|
|
the Rack PDU provides basic master power to the
|
|
outlets.
|
|
|
|
Allowed values are:
|
|
-1 - never apply power automatically.
|
|
0 - apply power immediately.
|
|
1 to 300 - delay up to 300 seconds (5 minutes)."
|
|
::= { ePDU2DeviceConfigEntry 7 }
|
|
|
|
ePDU2DeviceConfigCurrentLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined low current draw alarm threshold, measured in Amps."
|
|
::= { ePDU2DeviceConfigEntry 8 }
|
|
|
|
ePDU2DeviceConfigCurrentNearOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined near overload current threshold, measured in Amps."
|
|
::= { ePDU2DeviceConfigEntry 9 }
|
|
|
|
ePDU2DeviceConfigCurrentOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined current overload threshold, measured in Amps."
|
|
::= { ePDU2DeviceConfigEntry 10 }
|
|
|
|
ePDU2DeviceConfigPeakLoadReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation(1),
|
|
resetAll(2),
|
|
resetDevice(3),
|
|
resetOutlets(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to resetAll (2) will cause the existing peak current value
|
|
of Rack PDU and its outlets to be replaced by the current load current value.
|
|
Setting this OID to resetDevice (3) to reset the Rack PDU only.
|
|
Setting this OID to resetOutlets (4) to reset the PDU outlets only.
|
|
|
|
Getting this OID will do nothing and return the noOperation(1) value."
|
|
::= { ePDU2DeviceConfigEntry 11 }
|
|
|
|
ePDU2DeviceConfigEnergyReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation(1),
|
|
resetAll(2),
|
|
resetDevice(3),
|
|
resetOutlets(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to resetAll (2) will cause the device energy meter value
|
|
to be reset to zero.
|
|
Setting this OID to resetDevice (3) to reset the Rack PDU only.
|
|
Setting this OID to resetOutlets (4) to reset the PDU outlets only.
|
|
|
|
Getting this OID in models that support this feature will do nothing
|
|
and return the noOperation(1) value."
|
|
::= { ePDU2DeviceConfigEntry 12 }
|
|
|
|
ePDU2DeviceConfigPowerLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined low power draw alarm threshold, measured in Watts."
|
|
::= { ePDU2DeviceConfigEntry 13 }
|
|
|
|
ePDU2DeviceConfigPowerNearOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined near overload power threshold, measured in Watts."
|
|
::= { ePDU2DeviceConfigEntry 14 }
|
|
|
|
ePDU2DeviceConfigPowerOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined power overload threshold, measured in Watts."
|
|
::= { ePDU2DeviceConfigEntry 15 }
|
|
|
|
-- Device Info Table
|
|
ePDU2DeviceInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2DeviceInfoEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU information."
|
|
::= { ePDU2Device 3 }
|
|
|
|
ePDU2DeviceInfoEntry OBJECT-TYPE
|
|
SYNTAX EPDU2DeviceInfoEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Information of the Rack PDU being queried."
|
|
INDEX {ePDU2DeviceInfoIndex}
|
|
::= { ePDU2DeviceInfoTable 1 }
|
|
|
|
EPDU2DeviceInfoEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2DeviceInfoIndex INTEGER,
|
|
ePDU2DeviceInfoModuleIndex INTEGER,
|
|
ePDU2DeviceInfoName DisplayString,
|
|
ePDU2DeviceInfoRating INTEGER,
|
|
ePDU2DeviceInfoNumOutlets INTEGER,
|
|
ePDU2DeviceInfoSwitchedOutlets INTEGER,
|
|
ePDU2DeviceInfoMeteredOutlets INTEGER,
|
|
ePDU2DeviceInfoNumPhases INTEGER,
|
|
ePDU2DeviceInfoNumBreakers INTEGER,
|
|
ePDU2DeviceInfoBreakerRating INTEGER,
|
|
ePDU2DeviceInfoOrientation INTEGER,
|
|
ePDU2DeviceInfoOutletLayout INTEGER
|
|
}
|
|
|
|
ePDU2DeviceInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU Information table entry."
|
|
::= {ePDU2DeviceInfoEntry 1}
|
|
|
|
ePDU2DeviceInfoModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2DeviceInfoEntry 2}
|
|
|
|
ePDU2DeviceInfoName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the name of the Rack PDU."
|
|
::= {ePDU2DeviceInfoEntry 3}
|
|
|
|
ePDU2DeviceInfoRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The electrical rating of the Rack PDU."
|
|
::= {ePDU2DeviceInfoEntry 4}
|
|
|
|
ePDU2DeviceInfoNumOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of outlets on the Rack PDU."
|
|
::= {ePDU2DeviceInfoEntry 5}
|
|
|
|
ePDU2DeviceInfoSwitchedOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of switched outlets on the Rack PDU."
|
|
::= {ePDU2DeviceInfoEntry 6}
|
|
|
|
ePDU2DeviceInfoMeteredOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of metered outlets on the Rack PDU."
|
|
::= {ePDU2DeviceInfoEntry 7}
|
|
|
|
ePDU2DeviceInfoNumPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of phases present in the Rack PDU."
|
|
::= {ePDU2DeviceInfoEntry 8}
|
|
|
|
ePDU2DeviceInfoNumBreakers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of metered banks present in the Rack PDU."
|
|
::= {ePDU2DeviceInfoEntry 9}
|
|
|
|
ePDU2DeviceInfoBreakerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum current rating, measured in Amps, for the Rack PDU.
|
|
Getting this OID will return rating of the circuit breakers on
|
|
the device if it has any."
|
|
::= {ePDU2DeviceInfoEntry 10}
|
|
|
|
ePDU2DeviceInfoOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
orientHorizontal (1),
|
|
orientVertical (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Rack PDU orientation."
|
|
::= {ePDU2DeviceInfoEntry 11}
|
|
|
|
ePDU2DeviceInfoOutletLayout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
seqPhaseToNeutral (1),
|
|
seqPhaseToPhase (2),
|
|
seqPhToNeu21PhToPh (3),
|
|
seqPhToPhGrouped (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return outlet layout for the device.
|
|
|
|
SeqPhaseToNeutral(1) indicates outlet layout as follows:
|
|
1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
|
|
|
|
SeqPhaseToPhase(2) indicates outlet layout as follows:
|
|
1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,...
|
|
|
|
SeqPhToNeu21PhToPh(3) indicates outlet layout as follows:
|
|
1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,...
|
|
|
|
SeqPhToPhGrouped(4) indicates outlet layout as follows:
|
|
Otlts1-8::(3-1),Otlts9-16::(2-3),Otlts17-24::(1-2)."
|
|
::= {ePDU2DeviceInfoEntry 12}
|
|
|
|
-- Device Status Table
|
|
ePDU2DeviceStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2DeviceStatusEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU current status."
|
|
::= { ePDU2Device 4 }
|
|
|
|
ePDU2DeviceStatusEntry OBJECT-TYPE
|
|
SYNTAX EPDU2DeviceStatusEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status data from the Rack PDU being queried."
|
|
INDEX {ePDU2DeviceStatusIndex}
|
|
::= { ePDU2DeviceStatusTable 1 }
|
|
|
|
EPDU2DeviceStatusEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2DeviceStatusIndex INTEGER,
|
|
ePDU2DeviceStatusModuleIndex INTEGER,
|
|
ePDU2DeviceStatusName DisplayString,
|
|
ePDU2DeviceStatusLoadState INTEGER,
|
|
ePDU2DeviceStatusCurrentLoad Gauge,
|
|
ePDU2DeviceStatusCurrentPeakLoad Gauge,
|
|
ePDU2DeviceStatusPeakLoadTimestamp DisplayString,
|
|
ePDU2DeviceStatusPeakLoadStartTime DisplayString,
|
|
ePDU2DeviceStatusEnergy Gauge,
|
|
ePDU2DeviceStatusEnergyStartTime DisplayString,
|
|
ePDU2DeviceStatusCommandPending INTEGER,
|
|
ePDU2DeviceStatusPowerSupplyAlarm INTEGER,
|
|
ePDU2DeviceStatusPowerSupply1Status INTEGER,
|
|
ePDU2DeviceStatusPowerSupply2Status INTEGER,
|
|
ePDU2DeviceStatusApparentPower Gauge,
|
|
ePDU2DeviceStatusPowerFactor Gauge,
|
|
ePDU2DeviceStatusRoleType INTEGER,
|
|
ePDU2DeviceStatusPowerLoad Gauge,
|
|
ePDU2DeviceStatusPowerPeakLoad Gauge
|
|
}
|
|
|
|
ePDU2DeviceStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU status table entry."
|
|
::= {ePDU2DeviceStatusEntry 1}
|
|
|
|
ePDU2DeviceStatusModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID"
|
|
::= {ePDU2DeviceStatusEntry 2}
|
|
|
|
ePDU2DeviceStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the name of the Rack PDU."
|
|
::= {ePDU2DeviceStatusEntry 3}
|
|
|
|
ePDU2DeviceStatusLoadState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noLoadAlarm (1),
|
|
underCurrentAlarm (2),
|
|
nearOverCurrentAlarm (3),
|
|
overCurrentAlarm (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present load status of the Rack PDU."
|
|
::= {ePDU2DeviceStatusEntry 4}
|
|
|
|
ePDU2DeviceStatusCurrentLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power consumption of the Rack PDU load in tenths of Amps."
|
|
::= {ePDU2DeviceStatusEntry 5}
|
|
|
|
ePDU2DeviceStatusCurrentPeakLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak power consumption of the Rack PDU load in tenths of Amps."
|
|
::= {ePDU2DeviceStatusEntry 6}
|
|
|
|
ePDU2DeviceStatusPeakLoadTimestamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time that peak load occurred."
|
|
::= {ePDU2DeviceStatusEntry 7}
|
|
|
|
ePDU2DeviceStatusPeakLoadStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time of the last device peak load reset."
|
|
::= {ePDU2DeviceStatusEntry 8}
|
|
|
|
ePDU2DeviceStatusEnergy OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user resettable energy meter measuring Rack PDU load
|
|
energy consumption in tenths of kilowatt-hours."
|
|
::= {ePDU2DeviceStatusEntry 9}
|
|
|
|
ePDU2DeviceStatusEnergyStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time of the last device energy
|
|
meter reset."
|
|
::= {ePDU2DeviceStatusEntry 10}
|
|
|
|
ePDU2DeviceStatusCommandPending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
commandPending (1),
|
|
noCommandPending (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not the device
|
|
is processing a pending command."
|
|
::= {ePDU2DeviceStatusEntry 11}
|
|
|
|
ePDU2DeviceStatusPowerSupplyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates a power supply alarm is active when value
|
|
equals alarm (2)."
|
|
::= {ePDU2DeviceStatusEntry 12}
|
|
|
|
ePDU2DeviceStatusPowerSupply1Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not an alarm is active in Power
|
|
Supply 1."
|
|
::= {ePDU2DeviceStatusEntry 13}
|
|
|
|
ePDU2DeviceStatusPowerSupply2Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether or not an alarm is active in Power
|
|
Supply 2."
|
|
::= {ePDU2DeviceStatusEntry 14}
|
|
|
|
ePDU2DeviceStatusApparentPower OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The apparent power consumption of the Rack PDU
|
|
load in VoltAmps (VA)."
|
|
::= {ePDU2DeviceStatusEntry 15}
|
|
|
|
ePDU2DeviceStatusPowerFactor OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power factor of the Rack PDU load in hundredths."
|
|
::= {ePDU2DeviceStatusEntry 16}
|
|
|
|
ePDU2DeviceStatusRoleType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standalone (1),
|
|
host (2) ,
|
|
slave (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Get this oid shows the role the PDU played on Daisy Chain Group.
|
|
The PDU as a Host can access whole ePDU2 content, and the PDU be standalong
|
|
or a Slave can access itself instead."
|
|
::= {ePDU2DeviceStatusEntry 17}
|
|
|
|
ePDU2DeviceStatusPowerLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power consumption of the Rack PDU load in Watts."
|
|
::= {ePDU2DeviceStatusEntry 18}
|
|
|
|
ePDU2DeviceStatusPowerPeakLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak power consumption of the Rack PDU load in Watts."
|
|
::= {ePDU2DeviceStatusEntry 19}
|
|
|
|
-- Device Control Table
|
|
ePDU2DeviceControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2DeviceControlEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU control data."
|
|
::= { ePDU2Device 5 }
|
|
|
|
ePDU2DeviceControlEntry OBJECT-TYPE
|
|
SYNTAX EPDU2DeviceControlEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control data from Rack PDU being queried."
|
|
INDEX {ePDU2DeviceControlIndex}
|
|
::= {ePDU2DeviceControlTable 1}
|
|
|
|
EPDU2DeviceControlEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2DeviceControlIndex INTEGER,
|
|
ePDU2DeviceControlModuleIndex INTEGER,
|
|
ePDU2DeviceControlName DisplayString,
|
|
ePDU2DeviceControlCommand INTEGER
|
|
}
|
|
|
|
ePDU2DeviceControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU control table entry."
|
|
::= {ePDU2DeviceControlEntry 1}
|
|
|
|
ePDU2DeviceControlModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2DeviceControlEntry 2}
|
|
|
|
ePDU2DeviceControlName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the name of the Rack PDU."
|
|
::= {ePDU2DeviceControlEntry 3}
|
|
|
|
ePDU2DeviceControlCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
immediateAllOn (1),
|
|
immediateAllOff (2),
|
|
immediateAllReboot (3),
|
|
delayedAllOn (4),
|
|
delayedAllOff (5),
|
|
delayedAllReboot (6),
|
|
cancelAllPendingCommand (7),
|
|
noCommand (8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to immediateAllOn (1) will turn all outlets on immediately.
|
|
|
|
Setting this OID to immediateAllOff (2) will turn all outlets off immediately.
|
|
|
|
Setting this OID to immediateAllReboot (3) will cause an immediateAllOff command
|
|
to be performed. Once all outlets are off, the Switched Rack PDU will then delay
|
|
the ePDU2OutletSwitchedConfigRebootDuration OID time, and then perform an
|
|
immediateAllOn command.
|
|
|
|
Setting this OID to delayedAllOn (4) will turn all outlets on as defined by
|
|
each outlet's ePDU2OutletSwitchedConfigPowerOnTime OID value.
|
|
|
|
Setting this OID to delayedAllOff (5) will turn all outlets off as defined by
|
|
each outlet's ePDU2OutletSwitchedConfigPowerOffTime OID value.
|
|
|
|
Setting this OID to delayedAllReboot (6) will cause a delayedAllOff command
|
|
to be performed. Once all outlets are off, the Switched Rack PDU will then
|
|
delay the largest ePDU2OutletSwitchedConfigRebootDuration OID time, and
|
|
then perform a delayedAllOn command.
|
|
|
|
Setting this OID to cancelAllPendingCommand (7) will cause all pending
|
|
commands on the Switched Rack PDU to be cancelled.
|
|
|
|
Setting this OID to noCommand (8) will have no effect.
|
|
|
|
Getting this OID will return the noCommand (8) value."
|
|
::= {ePDU2DeviceControlEntry 4}
|
|
|
|
-- ePDU2Phase
|
|
ePDU2PhaseTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Host Rack PDU response total phase number of Rack PDUs on daisy chain.
|
|
Rack PDU as a Slave can only response itself number of phase."
|
|
::= {ePDU2Phase 1}
|
|
|
|
ePDU2PhaseConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2PhaseConfigEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU phase configuration data."
|
|
::= {ePDU2Phase 2}
|
|
|
|
ePDU2PhaseConfigEntry OBJECT-TYPE
|
|
SYNTAX EPDU2PhaseConfigEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from currently queried
|
|
Rack PDU phase."
|
|
INDEX {ePDU2PhaseConfigIndex}
|
|
::= {ePDU2PhaseConfigTable 1}
|
|
|
|
EPDU2PhaseConfigEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2PhaseConfigIndex INTEGER,
|
|
ePDU2PhaseConfigModuleIndex INTEGER,
|
|
ePDU2PhaseConfigNumber INTEGER,
|
|
ePDU2PhaseConfigOverloadRestriction INTEGER,
|
|
ePDU2PhaseConfigLowLoadThreshold INTEGER,
|
|
ePDU2PhaseConfigNearOverloadThreshold INTEGER,
|
|
ePDU2PhaseConfigOverloadThreshold INTEGER,
|
|
ePDU2PhaseConfigPhasePeakLoadReset INTEGER
|
|
}
|
|
|
|
ePDU2PhaseConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase configuration
|
|
table entry."
|
|
::= {ePDU2PhaseConfigEntry 1}
|
|
|
|
ePDU2PhaseConfigModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2PhaseConfigEntry 2}
|
|
|
|
ePDU2PhaseConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric phase ID."
|
|
::= {ePDU2PhaseConfigEntry 3}
|
|
|
|
ePDU2PhaseConfigOverloadRestriction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notSupported (-1),
|
|
alwaysAllowTurnON (1),
|
|
restrictOnNearOverload (2),
|
|
restrictOnOverload (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID controls the behavior of a Switched Rack PDU
|
|
phase when an overload condition is possible and
|
|
additional outlets are requested to be turned on.
|
|
|
|
Setting this OID to alwaysAllowTurnON (1) will always allow
|
|
the outlets on the corresponding phase to turn on.
|
|
|
|
Setting this OID to restrictOnNearOverload (2) will not allow
|
|
outlets on the corresponding phase to turn on if the
|
|
ePDU2PhaseConfigNearOverloadThreshold OID is exceeded.
|
|
|
|
Setting this OID to restrictOnOverload (3) will not allow
|
|
outlets on the corresponding phase to turn on if the
|
|
ePDU2PhaseConfigOverloadThreshold OID is exceeded.
|
|
|
|
Models that do not support this feature will respond to this OID
|
|
with a value of notSupported (-1). Attempts to set this OID
|
|
in these models will fail."
|
|
::= {ePDU2PhaseConfigEntry 4}
|
|
|
|
ePDU2PhaseConfigLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined low load phase current threshold in Amps."
|
|
::= {ePDU2PhaseConfigEntry 5}
|
|
|
|
ePDU2PhaseConfigNearOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined near phase overload current warning
|
|
threshold in Amps."
|
|
::= {ePDU2PhaseConfigEntry 6}
|
|
|
|
ePDU2PhaseConfigOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined phase overload current threshold
|
|
in Amps"
|
|
::= {ePDU2PhaseConfigEntry 7}
|
|
|
|
ePDU2PhaseConfigPhasePeakLoadReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the existing peak current value
|
|
to be replaced by the present load current value.
|
|
|
|
Getting this OID will do nothing and return the noOperation(1) value."
|
|
::= {ePDU2PhaseConfigEntry 8}
|
|
|
|
ePDU2PhaseInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2PhaseInfoEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU phase information."
|
|
::= {ePDU2Phase 3}
|
|
|
|
ePDU2PhaseInfoEntry OBJECT-TYPE
|
|
SYNTAX EPDU2PhaseInfoEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Information data from currently queried Rack PDU phase."
|
|
INDEX {ePDU2PhaseInfoIndex}
|
|
::= {ePDU2PhaseInfoTable 1}
|
|
|
|
EPDU2PhaseInfoEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2PhaseInfoIndex INTEGER,
|
|
ePDU2PhaseInfoModuleIndex INTEGER,
|
|
ePDU2PhaseInfoNumber INTEGER
|
|
}
|
|
|
|
ePDU2PhaseInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase properties table entry."
|
|
::= {ePDU2PhaseInfoEntry 1}
|
|
|
|
ePDU2PhaseInfoModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2PhaseInfoEntry 2}
|
|
|
|
ePDU2PhaseInfoNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric phase ID."
|
|
::= {ePDU2PhaseInfoEntry 3}
|
|
|
|
ePDU2PhaseStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2PhaseStatusEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU phase status data"
|
|
::= {ePDU2Phase 4}
|
|
|
|
ePDU2PhaseStatusEntry OBJECT-TYPE
|
|
SYNTAX EPDU2PhaseStatusEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status data from currently queried Rack PDU phase"
|
|
INDEX {ePDU2PhaseStatusIndex}
|
|
::= {ePDU2PhaseStatusTable 1}
|
|
|
|
EPDU2PhaseStatusEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2PhaseStatusIndex INTEGER,
|
|
ePDU2PhaseStatusModuleIndex INTEGER,
|
|
ePDU2PhaseStatusNumber INTEGER,
|
|
ePDU2PhaseStatusLoadState INTEGER,
|
|
ePDU2PhaseStatusLoad Gauge,
|
|
ePDU2PhaseStatusVoltage Gauge,
|
|
ePDU2PhaseStatusPower Gauge,
|
|
ePDU2PhaseStatusApparentPower Gauge,
|
|
ePDU2PhaseStatusPowerFactor Gauge,
|
|
ePDU2PhaseStatusPeakLoad Gauge,
|
|
ePDU2PhaseStatusPeakLoadTimestamp DisplayString,
|
|
ePDU2PhaseStatusPeakLoadStartTime DisplayString,
|
|
ePDU2PhaseStatusLineToLineVoltage Gauge
|
|
}
|
|
|
|
ePDU2PhaseStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..13)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase status table entry."
|
|
::= {ePDU2PhaseStatusEntry 1}
|
|
|
|
ePDU2PhaseStatusModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2PhaseStatusEntry 2}
|
|
|
|
ePDU2PhaseStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric phase ID."
|
|
::= {ePDU2PhaseStatusEntry 3}
|
|
|
|
ePDU2PhaseStatusLoadState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
lowLoad (2),
|
|
nearOverload (3),
|
|
overload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present load status of the Rack
|
|
PDU phase being queried."
|
|
::= {ePDU2PhaseStatusEntry 4}
|
|
|
|
ePDU2PhaseStatusLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the current draw, in tenths of Amps, of the load
|
|
on the Rack PDU phase being queried."
|
|
::= {ePDU2PhaseStatusEntry 5}
|
|
|
|
ePDU2PhaseStatusVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Voltage, in tenths of Volts, of the Rack
|
|
PDU phase being queried"
|
|
::= {ePDU2PhaseStatusEntry 6}
|
|
|
|
ePDU2PhaseStatusPower OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the load power, in watts,
|
|
consumed on the Rack PDU phase being queried"
|
|
::= {ePDU2PhaseStatusEntry 7}
|
|
|
|
ePDU2PhaseStatusApparentPower OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the load apparent power, in VoltAmps (VA),
|
|
consumed on the Rack PDU phase being queried"
|
|
::= {ePDU2PhaseStatusEntry 8}
|
|
|
|
ePDU2PhaseStatusPowerFactor OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the load power factor, in hundredths,
|
|
of the Rack PDU phase being queried"
|
|
::= {ePDU2PhaseStatusEntry 9}
|
|
|
|
ePDU2PhaseStatusPeakLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak current of the Rack PDU phase load in tenths of Amps"
|
|
::= {ePDU2PhaseStatusEntry 10}
|
|
|
|
ePDU2PhaseStatusPeakLoadTimestamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time the phase peak current occurred."
|
|
::= {ePDU2PhaseStatusEntry 11}
|
|
|
|
ePDU2PhaseStatusPeakLoadStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time of the last phase peak current reset."
|
|
::= {ePDU2PhaseStatusEntry 12}
|
|
|
|
ePDU2PhaseStatusLineToLineVoltage OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Line to Line Voltage, in tenths of Volts, of the Rack
|
|
PDU phase being queried"
|
|
::= {ePDU2PhaseStatusEntry 13}
|
|
|
|
-- ePDU2Bank
|
|
ePDU2BankTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Host Rack PDU response total bank number of Rack PDUs on daisy chain.
|
|
Rack PDU as a Slave can only response itself number of bank."
|
|
::= {ePDU2Bank 1}
|
|
|
|
ePDU2BankConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2BankConfigEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU bank configuration data."
|
|
::= {ePDU2Bank 2}
|
|
|
|
ePDU2BankConfigEntry OBJECT-TYPE
|
|
SYNTAX EPDU2BankConfigEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from currently queried
|
|
Rack PDU bank."
|
|
INDEX {ePDU2BankConfigIndex}
|
|
::= {ePDU2BankConfigTable 1}
|
|
|
|
EPDU2BankConfigEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2BankConfigIndex INTEGER,
|
|
ePDU2BankConfigModuleIndex INTEGER,
|
|
ePDU2BankConfigNumber INTEGER,
|
|
ePDU2BankConfigOverloadRestriction INTEGER,
|
|
ePDU2BankConfigLowLoadThreshold INTEGER,
|
|
ePDU2BankConfigNearOverloadThreshold INTEGER,
|
|
ePDU2BankConfigOverloadThreshold INTEGER,
|
|
ePDU2BankConfigPeakLoadReset INTEGER
|
|
}
|
|
|
|
ePDU2BankConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU bank configuration
|
|
table entry."
|
|
::= {ePDU2BankConfigEntry 1}
|
|
|
|
ePDU2BankConfigModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2BankConfigEntry 2}
|
|
|
|
ePDU2BankConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric bank ID."
|
|
::= {ePDU2BankConfigEntry 3}
|
|
|
|
ePDU2BankConfigOverloadRestriction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysAllowTurnON (1),
|
|
restrictOnNearOverload (2),
|
|
restrictOnOverload (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID controls the behavior of a Switched Rack PDU
|
|
bank when an overload condition is possible and
|
|
additional outlets are requested to be turned on.
|
|
|
|
Setting this OID to alwaysAllowTurnON (1) will always allow
|
|
the outlets on the corresponding bank to turn on.
|
|
|
|
Setting this OID to restrictOnNearOverload (2) will not allow
|
|
outlets on the corresponding bank to turn on if the
|
|
ePDU2BankConfigNearOverloadThreshold OID is exceeded.
|
|
|
|
Setting this OID to restrictOnOverload (3) will not allow
|
|
outlets on the corresponding bank to turn on if the
|
|
ePDU2BankConfigOverloadThreshold OID is exceeded."
|
|
::= {ePDU2BankConfigEntry 4}
|
|
|
|
ePDU2BankConfigLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined low load bank current threshold in Amps."
|
|
::= {ePDU2BankConfigEntry 5}
|
|
|
|
ePDU2BankConfigNearOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined near bank overload current warning
|
|
threshold in Amps."
|
|
::= {ePDU2BankConfigEntry 6}
|
|
|
|
ePDU2BankConfigOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined bank overload current threshold
|
|
in Amps"
|
|
::= {ePDU2BankConfigEntry 7}
|
|
|
|
ePDU2BankConfigPeakLoadReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the existing peak current value
|
|
to be replaced by the present load current value.
|
|
|
|
Getting this OID will do nothing and return the noOperation(1) value."
|
|
::= {ePDU2BankConfigEntry 8}
|
|
|
|
ePDU2BankInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2BankInfoEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU bank information."
|
|
::= {ePDU2Bank 3}
|
|
|
|
ePDU2BankInfoEntry OBJECT-TYPE
|
|
SYNTAX EPDU2BankInfoEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Information data from currently queried Rack PDU bank."
|
|
INDEX {ePDU2BankInfoIndex}
|
|
::= {ePDU2BankInfoTable 1}
|
|
|
|
EPDU2BankInfoEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2BankInfoIndex INTEGER,
|
|
ePDU2BankInfoModuleIndex INTEGER,
|
|
ePDU2BankInfoNumber INTEGER
|
|
}
|
|
|
|
ePDU2BankInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU bank properties table entry."
|
|
::= {ePDU2BankInfoEntry 1}
|
|
|
|
ePDU2BankInfoModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2BankInfoEntry 2}
|
|
|
|
ePDU2BankInfoNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric bank ID."
|
|
::= {ePDU2BankInfoEntry 3}
|
|
|
|
ePDU2BankStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2BankStatusEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU bank status data"
|
|
::= {ePDU2Bank 4}
|
|
|
|
ePDU2BankStatusEntry OBJECT-TYPE
|
|
SYNTAX EPDU2BankStatusEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status data from currently queried Rack PDU bank"
|
|
INDEX {ePDU2BankStatusIndex}
|
|
::= {ePDU2BankStatusTable 1}
|
|
|
|
EPDU2BankStatusEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2BankStatusIndex INTEGER,
|
|
ePDU2BankStatusModuleIndex INTEGER,
|
|
ePDU2BankStatusNumber INTEGER,
|
|
ePDU2BankStatusLoadState INTEGER,
|
|
ePDU2BankStatusLoad Gauge,
|
|
ePDU2BankStatusPeakLoad Gauge,
|
|
ePDU2BankStatusPeakLoadTimestamp DisplayString,
|
|
ePDU2BankStatusPeakLoadStartTime DisplayString
|
|
}
|
|
|
|
ePDU2BankStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU bank status table entry."
|
|
::= {ePDU2BankStatusEntry 1}
|
|
|
|
ePDU2BankStatusModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2BankStatusEntry 2}
|
|
|
|
ePDU2BankStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric bank ID."
|
|
::= {ePDU2BankStatusEntry 3}
|
|
|
|
ePDU2BankStatusLoadState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
lowLoad (2),
|
|
nearOverload (3),
|
|
overload (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present load status of the Rack
|
|
PDU bank being queried."
|
|
::= {ePDU2BankStatusEntry 4}
|
|
|
|
ePDU2BankStatusLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the current draw, in tenths of Amps, of the load
|
|
on the Rack PDU bank being queried."
|
|
::= {ePDU2BankStatusEntry 5}
|
|
|
|
ePDU2BankStatusPeakLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak current of the Rack PDU bank load in tenths of Amps."
|
|
::= {ePDU2BankStatusEntry 6}
|
|
|
|
ePDU2BankStatusPeakLoadTimestamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time the bank peak current occurred."
|
|
::= {ePDU2BankStatusEntry 7}
|
|
|
|
ePDU2BankStatusPeakLoadStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time of the last bank peak current reset."
|
|
::= {ePDU2BankStatusEntry 8}
|
|
|
|
-- ePDU2Outlet
|
|
ePDU2OutletSwitchedTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of switched outlets on connected Rack PDUs."
|
|
::= {ePDU2OutletSwitched 1}
|
|
|
|
ePDU2OutletSwitchedConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2OutletSwitchedConfigEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU switched outlet configuration data."
|
|
::= {ePDU2OutletSwitched 2}
|
|
|
|
ePDU2OutletSwitchedConfigEntry OBJECT-TYPE
|
|
SYNTAX EPDU2OutletSwitchedConfigEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from currently queried Rack PDU
|
|
switched outlet."
|
|
INDEX {ePDU2OutletSwitchedConfigIndex}
|
|
::= {ePDU2OutletSwitchedConfigTable 1}
|
|
|
|
EPDU2OutletSwitchedConfigEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2OutletSwitchedConfigIndex INTEGER,
|
|
ePDU2OutletSwitchedConfigModuleIndex INTEGER,
|
|
ePDU2OutletSwitchedConfigNumber INTEGER,
|
|
ePDU2OutletSwitchedConfigName DisplayString,
|
|
ePDU2OutletSwitchedConfigPowerOnTime INTEGER,
|
|
ePDU2OutletSwitchedConfigPowerOffTime INTEGER,
|
|
ePDU2OutletSwitchedConfigRebootDuration INTEGER
|
|
}
|
|
|
|
ePDU2OutletSwitchedConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..96)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU switched outlet configuration table entry."
|
|
::= {ePDU2OutletSwitchedConfigEntry 1}
|
|
|
|
ePDU2OutletSwitchedConfigModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2OutletSwitchedConfigEntry 2}
|
|
|
|
ePDU2OutletSwitchedConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID."
|
|
::= {ePDU2OutletSwitchedConfigEntry 3}
|
|
|
|
ePDU2OutletSwitchedConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined switched outlet name string."
|
|
::= {ePDU2OutletSwitchedConfigEntry 4}
|
|
|
|
ePDU2OutletSwitchedConfigPowerOnTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) the outlet will delay
|
|
powering on at coldstart or when a command that requires
|
|
a turn-on delay is issued.
|
|
|
|
Allowed values are:
|
|
-1 - never power on.
|
|
0 - power on immediately.
|
|
1 to 7200 - power on up to 7200 seconds after being
|
|
commanded."
|
|
::= {ePDU2OutletSwitchedConfigEntry 5}
|
|
|
|
ePDU2OutletSwitchedConfigPowerOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time (in seconds) the outlet will delay
|
|
powering off when a command that requires a
|
|
turn-off delay is issued.
|
|
|
|
Allowed values are:
|
|
-1 - never power off.
|
|
0 - power off immediately.
|
|
1 to 7200 - power off up to 7200 seconds after being
|
|
commanded."
|
|
::= {ePDU2OutletSwitchedConfigEntry 6}
|
|
|
|
ePDU2OutletSwitchedConfigRebootDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"During a reboot sequence, power is turned off and then
|
|
back on. This OID defines the amount of time to wait,
|
|
in seconds, after turning the power off, at the start
|
|
of the sequence, before turning power back on, at the
|
|
end of the reboot sequence.
|
|
|
|
Allowed range is any value between 5 and 60 seconds (1 minute)."
|
|
::= {ePDU2OutletSwitchedConfigEntry 7}
|
|
|
|
ePDU2OutletSwitchedInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2OutletSwitchedInfoEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU switched outlet information."
|
|
::= {ePDU2OutletSwitched 3}
|
|
|
|
ePDU2OutletSwitchedInfoEntry OBJECT-TYPE
|
|
SYNTAX EPDU2OutletSwitchedInfoEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Information of the currently queried Rack PDU
|
|
switched outlet."
|
|
INDEX {ePDU2OutletSwitchedInfoIndex}
|
|
::= {ePDU2OutletSwitchedInfoTable 1}
|
|
|
|
EPDU2OutletSwitchedInfoEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2OutletSwitchedInfoIndex INTEGER,
|
|
ePDU2OutletSwitchedInfoModuleIndex INTEGER,
|
|
ePDU2OutletSwitchedInfoNumber INTEGER,
|
|
ePDU2OutletSwitchedInfoName DisplayString,
|
|
ePDU2OutletSwitchedInfoPhaseLayout INTEGER,
|
|
ePDU2OutletSwitchedInfoBank INTEGER
|
|
}
|
|
|
|
ePDU2OutletSwitchedInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..96)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU switched outlet information table entry."
|
|
::= {ePDU2OutletSwitchedInfoEntry 1}
|
|
|
|
ePDU2OutletSwitchedInfoModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2OutletSwitchedInfoEntry 2}
|
|
|
|
ePDU2OutletSwitchedInfoNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID."
|
|
::= {ePDU2OutletSwitchedInfoEntry 3}
|
|
|
|
ePDU2OutletSwitchedInfoName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet name."
|
|
::= {ePDU2OutletSwitchedInfoEntry 4}
|
|
|
|
ePDU2OutletSwitchedInfoPhaseLayout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID describes the phase connections of the referenced outlet as follows:
|
|
seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral.
|
|
seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral.
|
|
seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral.
|
|
seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2.
|
|
seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3.
|
|
seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1."
|
|
::= {ePDU2OutletSwitchedInfoEntry 5}
|
|
|
|
ePDU2OutletSwitchedInfoBank OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric bank ID."
|
|
::= {ePDU2OutletSwitchedInfoEntry 6}
|
|
|
|
ePDU2OutletSwitchedStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2OutletSwitchedStatusEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU switched outlet status information."
|
|
::= {ePDU2OutletSwitched 4}
|
|
|
|
ePDU2OutletSwitchedStatusEntry OBJECT-TYPE
|
|
SYNTAX EPDU2OutletSwitchedStatusEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status information for currently queried Rack PDU switched outlet."
|
|
INDEX {ePDU2OutletSwitchedStatusIndex}
|
|
::= {ePDU2OutletSwitchedStatusTable 1}
|
|
|
|
EPDU2OutletSwitchedStatusEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2OutletSwitchedStatusIndex INTEGER,
|
|
ePDU2OutletSwitchedStatusModuleIndex INTEGER,
|
|
ePDU2OutletSwitchedStatusNumber INTEGER,
|
|
ePDU2OutletSwitchedStatusName DisplayString,
|
|
ePDU2OutletSwitchedStatusState INTEGER,
|
|
ePDU2OutletSwitchedStatusCommandPending INTEGER
|
|
}
|
|
|
|
ePDU2OutletSwitchedStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..96)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU switched outlet status information table entry."
|
|
::= {ePDU2OutletSwitchedStatusEntry 1}
|
|
|
|
ePDU2OutletSwitchedStatusModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2OutletSwitchedStatusEntry 2}
|
|
|
|
ePDU2OutletSwitchedStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID."
|
|
::= {ePDU2OutletSwitchedStatusEntry 3}
|
|
|
|
ePDU2OutletSwitchedStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined switched outlet name string."
|
|
::= {ePDU2OutletSwitchedStatusEntry 4}
|
|
|
|
ePDU2OutletSwitchedStatusState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletStatusOn (1),
|
|
outletStatusOff (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present switch state of the Rack PDU switched outlet being queried."
|
|
::= {ePDU2OutletSwitchedStatusEntry 5}
|
|
|
|
ePDU2OutletSwitchedStatusCommandPending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletStatusCommandPending (1),
|
|
outletStatusNoCommandPending (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the command pending state of the outlet.
|
|
If a command is pending on the outlet, the outletStatusCommandPending (1)
|
|
value will be returned. If there is not a command pending on the outlet,
|
|
the outletStatusNoCommandPending (2) will be returned."
|
|
::= {ePDU2OutletSwitchedStatusEntry 6}
|
|
|
|
ePDU2OutletSwitchedControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2OutletSwitchedControlEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU switched outlet control data."
|
|
::= {ePDU2OutletSwitched 5}
|
|
|
|
ePDU2OutletSwitchedControlEntry OBJECT-TYPE
|
|
SYNTAX EPDU2OutletSwitchedControlEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control data for currently queried Rack PDU switched outlet."
|
|
INDEX {ePDU2OutletSwitchedControlIndex}
|
|
::= {ePDU2OutletSwitchedControlTable 1}
|
|
|
|
EPDU2OutletSwitchedControlEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2OutletSwitchedControlIndex INTEGER,
|
|
ePDU2OutletSwitchedControlModuleIndex INTEGER,
|
|
ePDU2OutletSwitchedControlNumber INTEGER,
|
|
ePDU2OutletSwitchedControlName DisplayString,
|
|
ePDU2OutletSwitchedControlCommand INTEGER
|
|
}
|
|
|
|
ePDU2OutletSwitchedControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..96)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU switched outlet control data table entry."
|
|
::= {ePDU2OutletSwitchedControlEntry 1}
|
|
|
|
ePDU2OutletSwitchedControlModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID."
|
|
::= {ePDU2OutletSwitchedControlEntry 2}
|
|
|
|
ePDU2OutletSwitchedControlNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID."
|
|
::= {ePDU2OutletSwitchedControlEntry 3}
|
|
|
|
ePDU2OutletSwitchedControlName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined switched outlet name string."
|
|
::= {ePDU2OutletSwitchedControlEntry 4}
|
|
|
|
ePDU2OutletSwitchedControlCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
immediateOn (1),
|
|
immediateOff (2),
|
|
immediateReboot (3),
|
|
delayedOn (4),
|
|
delayedOff (5),
|
|
delayedReboot (6),
|
|
cancelPendingCommand (7),
|
|
outletIdentify (8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If
|
|
the outlet is on, the immediateOn (1) value will be returned.
|
|
If the outlet is off, the immediateOff (2) value will be returned.
|
|
|
|
Setting this variable to immediateOn (1) will immediately turn
|
|
the outlet on.
|
|
|
|
Setting this variable to immediateOff (2) will immediately turn
|
|
the outlet off.
|
|
|
|
Setting this variable to immediateReboot (3) will immediately
|
|
reboot the outlet.
|
|
|
|
Setting this variable to delayedOn (4) will turn the outlet on
|
|
after the ePDUOutletConfigPowerOnTime OID time has elapsed.
|
|
|
|
Setting this variable to delayedOff (5) will turn the outlet off
|
|
after the ePDUOutletConfigPowerOffTime OID time has elapsed.
|
|
|
|
Setting this variable to delayedReboot (6) will cause the
|
|
Switched Rack PDU to perform a delayedOff command, wait the
|
|
ePDUOutletConfigRebootDuration OID time, and then perform a
|
|
delayedOn command.
|
|
|
|
Setting this variable to cancelPendingCommand (7) will cause any
|
|
pending command to this outlet to be canceled.
|
|
|
|
Setting this variable to outletIdentify (8) will cause PDU LED
|
|
to display the number of the outlet."
|
|
::= {ePDU2OutletSwitchedControlEntry 5}
|
|
|
|
ePDU2OutletMeteredTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of metered outlets on connected Rack PDUs."
|
|
::= {ePDU2OutletMetered 1}
|
|
|
|
ePDU2OutletMeteredConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2OutletMeteredConfigEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU metered outlet configuration data."
|
|
::= {ePDU2OutletMetered 2}
|
|
|
|
ePDU2OutletMeteredConfigEntry OBJECT-TYPE
|
|
SYNTAX EPDU2OutletMeteredConfigEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from currently queried Rack PDU metered outlet."
|
|
INDEX {ePDU2OutletMeteredConfigIndex}
|
|
::= {ePDU2OutletMeteredConfigTable 1}
|
|
|
|
EPDU2OutletMeteredConfigEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2OutletMeteredConfigIndex INTEGER,
|
|
ePDU2OutletMeteredConfigModuleIndex INTEGER,
|
|
ePDU2OutletMeteredConfigNumber INTEGER,
|
|
ePDU2OutletMeteredConfigName DisplayString,
|
|
ePDU2OutletMeteredConfigLowLoadThreshold INTEGER,
|
|
ePDU2OutletMeteredConfigNearOverloadThreshold INTEGER,
|
|
ePDU2OutletMeteredConfigOverloadThreshold INTEGER
|
|
}
|
|
|
|
ePDU2OutletMeteredConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..96)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU metered outlet configuration table entry."
|
|
::= {ePDU2OutletMeteredConfigEntry 1}
|
|
|
|
ePDU2OutletMeteredConfigModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined Rack PDU numeric ID."
|
|
::= {ePDU2OutletMeteredConfigEntry 2}
|
|
|
|
ePDU2OutletMeteredConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric metered outlet ID."
|
|
::= {ePDU2OutletMeteredConfigEntry 3}
|
|
|
|
ePDU2OutletMeteredConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined metered outlet name string."
|
|
::= {ePDU2OutletMeteredConfigEntry 4}
|
|
|
|
ePDU2OutletMeteredConfigLowLoadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined outlet low load current threshold in Watts."
|
|
::= {ePDU2OutletMeteredConfigEntry 5}
|
|
|
|
ePDU2OutletMeteredConfigNearOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined outlet near overload warning threshold in Watts."
|
|
::= {ePDU2OutletMeteredConfigEntry 6}
|
|
|
|
ePDU2OutletMeteredConfigOverloadThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User-defined outlet overload current threshold in Watts."
|
|
::= {ePDU2OutletMeteredConfigEntry 7}
|
|
|
|
ePDU2OutletMeteredInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2OutletMeteredInfoEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU metered outlet information."
|
|
::= {ePDU2OutletMetered 3}
|
|
|
|
ePDU2OutletMeteredInfoEntry OBJECT-TYPE
|
|
SYNTAX EPDU2OutletMeteredInfoEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Information of currently queried Rack PDU metered outlet."
|
|
INDEX {ePDU2OutletMeteredInfoIndex}
|
|
::= {ePDU2OutletMeteredInfoTable 1}
|
|
|
|
EPDU2OutletMeteredInfoEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2OutletMeteredInfoIndex INTEGER,
|
|
ePDU2OutletMeteredInfoModuleIndex INTEGER,
|
|
ePDU2OutletMeteredInfoNumber INTEGER,
|
|
ePDU2OutletMeteredInfoName DisplayString,
|
|
ePDU2OutletMeteredInfoLayout INTEGER,
|
|
ePDU2OutletMeteredInfoRating INTEGER,
|
|
ePDU2OutletMeteredInfoBank INTEGER
|
|
}
|
|
|
|
ePDU2OutletMeteredInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..96)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU metered information table entry."
|
|
::= {ePDU2OutletMeteredInfoEntry 1}
|
|
|
|
ePDU2OutletMeteredInfoModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2OutletMeteredInfoEntry 2}
|
|
|
|
ePDU2OutletMeteredInfoNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric metered outlet ID."
|
|
::= {ePDU2OutletMeteredInfoEntry 3}
|
|
|
|
ePDU2OutletMeteredInfoName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined metered outlet name string."
|
|
::= {ePDU2OutletMeteredInfoEntry 4}
|
|
|
|
ePDU2OutletMeteredInfoLayout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID describes the phase connections of the referenced outlet as follows:
|
|
seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral.
|
|
seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral.
|
|
seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral.
|
|
seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2.
|
|
seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3.
|
|
seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1."
|
|
::= {ePDU2OutletMeteredInfoEntry 5}
|
|
|
|
ePDU2OutletMeteredInfoRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum power rating of Rack PDU metered outlet."
|
|
::= {ePDU2OutletMeteredInfoEntry 6}
|
|
|
|
ePDU2OutletMeteredInfoBank OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This outlet's numeric bank ID."
|
|
::= {ePDU2OutletMeteredInfoEntry 7}
|
|
|
|
ePDU2OutletMeteredStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EPDU2OutletMeteredStatusEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU metered outlet status data."
|
|
::= {ePDU2OutletMetered 4}
|
|
|
|
ePDU2OutletMeteredStatusEntry OBJECT-TYPE
|
|
SYNTAX EPDU2OutletMeteredStatusEntryStruct
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status data from currently queried Rack PDU metered outlet."
|
|
INDEX {ePDU2OutletMeteredStatusIndex}
|
|
::= {ePDU2OutletMeteredStatusTable 1}
|
|
|
|
EPDU2OutletMeteredStatusEntryStruct ::=
|
|
SEQUENCE {
|
|
ePDU2OutletMeteredStatusIndex INTEGER,
|
|
ePDU2OutletMeteredStatusModuleIndex INTEGER,
|
|
ePDU2OutletMeteredStatusNumber INTEGER,
|
|
ePDU2OutletMeteredStatusName DisplayString,
|
|
ePDU2OutletMeteredStatusAlarm INTEGER,
|
|
ePDU2OutletMeteredStatusLoad Gauge,
|
|
ePDU2OutletMeteredStatusActivePower Gauge,
|
|
ePDU2OutletMeteredStatusPeakPower Gauge,
|
|
ePDU2OutletMeteredStatusPeakPowerTimestamp DisplayString,
|
|
ePDU2OutletMeteredStatusPeakPowerStartTime DisplayString,
|
|
ePDU2OutletMeteredStatusEnergy Gauge,
|
|
ePDU2OutletMeteredStatusEnergyStart DisplayString
|
|
}
|
|
|
|
ePDU2OutletMeteredStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..96)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU metered status table entry."
|
|
::= {ePDU2OutletMeteredStatusEntry 1}
|
|
|
|
ePDU2OutletMeteredStatusModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU numeric ID."
|
|
::= {ePDU2OutletMeteredStatusEntry 2}
|
|
|
|
ePDU2OutletMeteredStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric metered outlet ID."
|
|
::= {ePDU2OutletMeteredStatusEntry 3}
|
|
|
|
ePDU2OutletMeteredStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined metered outlet name string."
|
|
::= {ePDU2OutletMeteredStatusEntry 4}
|
|
|
|
ePDU2OutletMeteredStatusAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noLoadAlarm (1),
|
|
underCurrentAlarm (2),
|
|
nearOverCurrentAlarm (3),
|
|
overCurrentAlarm (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the current outlet alarm."
|
|
::= {ePDU2OutletMeteredStatusEntry 5}
|
|
|
|
ePDU2OutletMeteredStatusLoad OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the measured Outlet load
|
|
for an Outlet Monitored Rack PDU in tenths of Amps."
|
|
::= {ePDU2OutletMeteredStatusEntry 6}
|
|
|
|
ePDU2OutletMeteredStatusActivePower OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the measured Outlet load for
|
|
an Outlet Monitored Rack PDU in watts."
|
|
::= {ePDU2OutletMeteredStatusEntry 7}
|
|
|
|
ePDU2OutletMeteredStatusPeakPower OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The peak power consumption of the Rack PDU load in watts."
|
|
::= {ePDU2OutletMeteredStatusEntry 8}
|
|
|
|
ePDU2OutletMeteredStatusPeakPowerTimestamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Get this oid shows the date and time that peak power
|
|
consumption occurred."
|
|
::= {ePDU2OutletMeteredStatusEntry 9}
|
|
|
|
ePDU2OutletMeteredStatusPeakPowerStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Get this oid shows the date and time that peak power
|
|
consumption started."
|
|
::= {ePDU2OutletMeteredStatusEntry 10}
|
|
|
|
ePDU2OutletMeteredStatusEnergy OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Energy meter measuring Rack PDU load energy consumption
|
|
in tenths of kilowatt-hours."
|
|
::= {ePDU2OutletMeteredStatusEntry 11}
|
|
|
|
ePDU2OutletMeteredStatusEnergyStart OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time of the last device energy
|
|
meter reset."
|
|
::= {ePDU2OutletMeteredStatusEntry 12}
|
|
|
|
-- ePDU2Sensor
|
|
ePDU2SensorTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "ePDU2SensorTableSize"
|
|
::= {ePDU2Sensor 1}
|
|
|
|
-- ePDU2Group
|
|
ePDU2GroupNumberOfDevices OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the number of Rack PDU devices contributing
|
|
to the Daisy Chain group power and energy values. Queries
|
|
to slave units in an Daisy Chain group will return 0."
|
|
::= {ePDU2Group 1}
|
|
|
|
ePDU2GroupTotalPower OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the total power consumption of the Rack PDU
|
|
Daisy Chain group devices in watts. Queries to slave
|
|
units in an Daisy Chain group will return 0."
|
|
::= {ePDU2Group 2}
|
|
|
|
ePDU2GroupTotalEnergy OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the total energy consumption of the Rack
|
|
PDU Daisy Chain group devices in tenths of kilowatt-hours.
|
|
|
|
To reset the energy meters for each of the Rack PDU devices that contribute
|
|
to this value, see the ePDU2GroupEnergyReset OID.
|
|
|
|
To view the start time for each of the Rack PDU device energy meters that
|
|
contribute to this value, see the ePDU2DeviceStatusEnergyStartTime OID.
|
|
|
|
Queries to slave units in an Daisy Chain group will return 0."
|
|
::= {ePDU2Group 3}
|
|
|
|
ePDU2GroupEnergyReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the device energy meter value
|
|
on each device in the Rack PDU Daisy Chain group to be reset to zero.
|
|
|
|
Getting this OID in models that support this feature will do nothing
|
|
and return the noOperation(1) value."
|
|
::= {ePDU2Group 4}
|
|
|
|
ePDU2GroupPeakRecordReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOperation (1),
|
|
reset (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to reset (2) will cause the device peak record value
|
|
on each device in the Rack PDU Daisy Chain group to be reset to current
|
|
load/power.
|
|
|
|
Getting this OID in models that support this feature will do nothing
|
|
and return the noOperation(1) value."
|
|
::= {ePDU2Group 5}
|
|
|
|
-- Battery Manager
|
|
bmIdentModelName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager model name."
|
|
::= { bmIdent 1 }
|
|
|
|
bmIdentHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager hardware version."
|
|
::= { bmIdent 2 }
|
|
|
|
bmIdentFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager firmware version."
|
|
::= { bmIdent 3 }
|
|
|
|
bmIdentLCDHardwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager LCD hardware version."
|
|
::= { bmIdent 4 }
|
|
|
|
bmIdentLCDFirmwareRev OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager LCD firmware version."
|
|
::= { bmIdent 5 }
|
|
|
|
bmIdentDateOfManufacture OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager manufacture date."
|
|
::= { bmIdent 6 }
|
|
|
|
bmIdentSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager serial number."
|
|
::= { bmIdent 7 }
|
|
|
|
bmIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager system identification name."
|
|
::= { bmIdent 8 }
|
|
|
|
bmIdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager system location."
|
|
::= { bmIdent 9 }
|
|
|
|
bmPropertyStringMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager max string count supported."
|
|
::= { bmProperty 1 }
|
|
|
|
bmPropertyMaxProbeOnString OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager max probes on a string supported."
|
|
::= { bmProperty 2 }
|
|
|
|
bmPropertyInputVoltageRange OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager line input voltage range."
|
|
::= { bmProperty 3 }
|
|
|
|
bmPropertyProbesRating OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
probeUnknown(1),
|
|
probe2V(2),
|
|
probe4V(3),
|
|
probe6V(4),
|
|
probe12V(5),
|
|
probeMixed(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery probes model rating."
|
|
::= { bmProperty 4 }
|
|
|
|
bmConfigBattAH OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager battery AH type configuration, unit in 0.1 AH."
|
|
::= { bmConfig 1 }
|
|
|
|
bmConfigStringCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager string count setting."
|
|
::= { bmConfig 2 }
|
|
|
|
bmConfigProbesCountOnString OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager probe count on a string setting."
|
|
::= { bmConfig 3 }
|
|
|
|
bmConfigLowVoltAlarmThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery low voltage alarm threshold setting, unit in 0.1 volt."
|
|
::= { bmConfig 4 }
|
|
|
|
bmConfigHighVoltAlarmThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery high voltage alarm threshold setting, unit in 0.1 volt."
|
|
::= { bmConfig 5 }
|
|
|
|
bmConfigVoltDiffAlarmThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Batteries within a string voltage difference threshold, unit in 0.1 volt."
|
|
::= { bmConfig 6 }
|
|
|
|
bmConfigLowTempAlarmThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery low temperature alarm threshold, unit in 0.1 degree C."
|
|
::= { bmConfig 7 }
|
|
|
|
bmConfigHighTempAlarmThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery high temperature alarm threshold, unit in 0.1 degree C."
|
|
::= { bmConfig 8 }
|
|
|
|
bmConfigLowResAlarmThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery low resistance alarm threshold, unit in 0.01 mOhm."
|
|
::= { bmConfig 9 }
|
|
|
|
bmConfigHighResAlarmThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery high resistance alarm threshold, unit in 0.01 mOhm."
|
|
::= { bmConfig 10 }
|
|
|
|
bmConfigLowResWarnThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery low resistance warning threshold, unit in 0.01 mOhm."
|
|
::= { bmConfig 11 }
|
|
|
|
bmConfigHighResWarnThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery high resistance warning threshold, unit in 0.01 mOhm."
|
|
::= { bmConfig 12 }
|
|
|
|
bmConfigResHealthAlarmThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery resistance health alarm threshold, unit in percentage and should larger than 100."
|
|
::= { bmConfig 13 }
|
|
|
|
bmConfigResHealthWarnThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery resistance health warn threshold, unit in percentage and should larger than 100."
|
|
::= { bmConfig 14 }
|
|
|
|
bmConfigLowVoltAlarmThreshold10mV OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery low voltage alarm threshold setting, unit in 10 mV (0.01 volt)."
|
|
::= { bmConfig 15 }
|
|
|
|
bmConfigHighVoltAlarmThreshold10mV OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery high voltage alarm threshold setting, unit in 10 mV (0.01 volt)."
|
|
::= { bmConfig 16 }
|
|
|
|
bmConfigMergeFeature OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"String merge feature setting."
|
|
::= { bmConfig 17 }
|
|
|
|
bmControlSysytemIdenticator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTestIndicators(1),
|
|
testIndicators(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager will perform a panel indicator test when the variable is set to testIndicators(2).
|
|
Get this oid will get noTestIndicators(1)."
|
|
::= { bmControl 1 }
|
|
|
|
bmControlProbeIndicator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTestIndicators(1),
|
|
testIndicators(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery manager will perform a probe indicator test when the variable is set to testIndicators(2).
|
|
Get this oid will get noTestIndicators(1)."
|
|
::= { bmControl 2 }
|
|
|
|
bmProbesNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current connected probe number."
|
|
::= { bmProbes 1 }
|
|
|
|
bmProbesTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current configured probe number."
|
|
::= { bmProbes 2 }
|
|
|
|
bmProbesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BmProbesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of status of probes."
|
|
::= { bmProbes 3 }
|
|
|
|
bmProbesEntry OBJECT-TYPE
|
|
SYNTAX BmProbesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of probes installation to gather status from."
|
|
INDEX { bmProbesIndex }
|
|
::= { bmProbesTable 1 }
|
|
|
|
BmProbesEntry ::=
|
|
SEQUENCE {
|
|
bmProbesIndex INTEGER,
|
|
bmProbesPackIndex INTEGER,
|
|
bmProbesStringIndex INTEGER,
|
|
bmProbesBattIndex INTEGER
|
|
}
|
|
|
|
bmProbesIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..960)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Probes table index"
|
|
::= { bmProbesEntry 1 }
|
|
|
|
bmProbesPackIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..64)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery pack number the probe installed."
|
|
::= { bmProbesEntry 2 }
|
|
|
|
bmProbesStringIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..16)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The string number the probe installed."
|
|
::= { bmProbesEntry 3 }
|
|
|
|
bmProbesBattIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..960)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery number the probe installed."
|
|
::= { bmProbesEntry 4 }
|
|
|
|
bmProbesVoltageTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the battery voltage table"
|
|
::= { bmProbes 4 }
|
|
|
|
bmProbesVoltageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BmProbesVoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of voltage of batteries."
|
|
::= { bmProbes 5 }
|
|
|
|
bmProbesVoltageEntry OBJECT-TYPE
|
|
SYNTAX BmProbesVoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Batteries voltage status."
|
|
INDEX { bmProbesVoltageIndex}
|
|
::= { bmProbesVoltageTable 1 }
|
|
|
|
BmProbesVoltageEntry ::=
|
|
SEQUENCE {
|
|
bmProbesVoltageIndex INTEGER,
|
|
bmProbesVoltagePackIndex INTEGER,
|
|
bmProbesVoltageStringIndex INTEGER,
|
|
bmProbesVoltageBattIndex INTEGER,
|
|
bmProbesVoltageProbeIndex INTEGER,
|
|
bmProbesVoltageAlarmStatus INTEGER,
|
|
bmProbesVoltage INTEGER,
|
|
bmProbesVoltageEqualPercentage INTEGER
|
|
}
|
|
|
|
bmProbesVoltageIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..960)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the voltage status entry."
|
|
::= { bmProbesVoltageEntry 1 }
|
|
|
|
bmProbesVoltagePackIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..64)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery pack index to the voltage record."
|
|
::= { bmProbesVoltageEntry 2 }
|
|
|
|
bmProbesVoltageStringIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..16)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery string index to the voltage record."
|
|
::= { bmProbesVoltageEntry 3 }
|
|
|
|
bmProbesVoltageBattIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..960)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery index to the voltage record within its string."
|
|
::= { bmProbesVoltageEntry 4 }
|
|
|
|
bmProbesVoltageProbeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..960)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The probe index to the voltage record."
|
|
::= { bmProbesVoltageEntry 5 }
|
|
|
|
bmProbesVoltageAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
voltageNormal(1),
|
|
voltageWarnLow(2),
|
|
voltageWarnHigh(3),
|
|
voltageAlarmLow(4),
|
|
voltageAlarmHigh(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery voltage alarm status."
|
|
::= { bmProbesVoltageEntry 6 }
|
|
|
|
bmProbesVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this oid to get battery voltage, unit in 10mV (0.01 volt)."
|
|
::= { bmProbesVoltageEntry 7 }
|
|
|
|
bmProbesVoltageEqualPercentage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this oid to get battery voltage equalizing power, unit in percentage."
|
|
::= { bmProbesVoltageEntry 8 }
|
|
|
|
bmProbesTempTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Temperature table"
|
|
::= { bmProbes 6 }
|
|
|
|
bmProbesTempTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BmProbesTempEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of temperature of probes."
|
|
::= { bmProbes 7 }
|
|
|
|
bmProbesTempEntry OBJECT-TYPE
|
|
SYNTAX BmProbesTempEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature status entry."
|
|
INDEX { bmProbesTempIndex }
|
|
::= { bmProbesTempTable 1 }
|
|
|
|
BmProbesTempEntry ::=
|
|
SEQUENCE {
|
|
bmProbesTempIndex INTEGER,
|
|
bmProbesTempPackIndex INTEGER,
|
|
bmProbesTempStringIndex INTEGER,
|
|
bmProbesTempBattIndex INTEGER,
|
|
bmProbesTempProbeIndex INTEGER,
|
|
bmProbesTempAlarmStatus INTEGER,
|
|
bmProbesTemperature INTEGER
|
|
}
|
|
|
|
bmProbesTempIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..960)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the temperature entry."
|
|
::= { bmProbesTempEntry 1 }
|
|
|
|
bmProbesTempPackIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..64)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery pack index of the temperature entry."
|
|
::= { bmProbesTempEntry 2 }
|
|
|
|
bmProbesTempStringIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..16)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the string."
|
|
::= { bmProbesTempEntry 3 }
|
|
|
|
bmProbesTempBattIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..960)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the battery."
|
|
::= { bmProbesTempEntry 4 }
|
|
|
|
bmProbesTempProbeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..960)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the probe."
|
|
::= { bmProbesTempEntry 5 }
|
|
|
|
bmProbesTempAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temperatureNormal(1),
|
|
temperatureWarnLow(2),
|
|
temperatureWarnHigh(3),
|
|
temperatureAlarmLow(4),
|
|
temperatureAlarmHigh(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm status of the temperature."
|
|
::= { bmProbesTempEntry 6 }
|
|
|
|
bmProbesTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER(-40..60)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature record, measure in 0.1 degree C."
|
|
::= { bmProbesTempEntry 7 }
|
|
|
|
bmProbesResTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the Resistance table"
|
|
::= { bmProbes 8 }
|
|
|
|
bmProbesResTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BmProbesResEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows for getting of resistance of probes."
|
|
::= { bmProbes 9 }
|
|
|
|
bmProbesResEntry OBJECT-TYPE
|
|
SYNTAX BmProbesResEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The resistance status entry."
|
|
INDEX { bmProbesResIndex }
|
|
::= { bmProbesResTable 1 }
|
|
|
|
BmProbesResEntry ::=
|
|
SEQUENCE {
|
|
bmProbesResIndex INTEGER,
|
|
bmProbesResPackIndex INTEGER,
|
|
bmProbesResStringIndex INTEGER,
|
|
bmProbesResBattIndex INTEGER,
|
|
bmProbesResProbeIndex INTEGER,
|
|
bmProbesResAlarmStatus INTEGER,
|
|
bmProbesResistance INTEGER,
|
|
bmProbesResHealth INTEGER
|
|
}
|
|
|
|
bmProbesResIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..960)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the resistance entry."
|
|
::= { bmProbesResEntry 1 }
|
|
|
|
bmProbesResPackIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..64)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The battery pack index to the resistance entry."
|
|
::= { bmProbesResEntry 2 }
|
|
|
|
bmProbesResStringIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..16)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the string."
|
|
::= { bmProbesResEntry 3 }
|
|
|
|
bmProbesResBattIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..960)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the battery."
|
|
::= { bmProbesResEntry 4 }
|
|
|
|
bmProbesResProbeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..960)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the probe."
|
|
::= { bmProbesResEntry 5 }
|
|
|
|
bmProbesResAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
resistanceNormal(1),
|
|
resistanceWarnLow(2),
|
|
resistanceWarnHigh(3),
|
|
resistanceAlarmLow(4),
|
|
resistanceAlarmHigh(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm status of the battery resistance."
|
|
::= { bmProbesResEntry 6 }
|
|
|
|
bmProbesResistance OBJECT-TYPE
|
|
SYNTAX INTEGER(-40..60)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The resistance of the battery, unit in 0.01 mOhm."
|
|
::= { bmProbesResEntry 7 }
|
|
|
|
bmProbesResHealth OBJECT-TYPE
|
|
SYNTAX INTEGER(-40..60)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The resistance health status, unit in percentage."
|
|
::= { bmProbesResEntry 8 }
|
|
|
|
bmFuncResMeasureInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time interval for battery manager to exercising resistance measurement, unit in hour(s)."
|
|
::= { bmFuncResMeasure 1 }
|
|
|
|
bmFuncResMeasureManualCmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noResMeasure(1),
|
|
resMeasureNow(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This oid allows user to manual resistance measurement.
|
|
Set this oid to measureResNow(2) to measure resistance immediately.
|
|
|
|
Get bmFuncResMeasureLastCmdResult oid to check command acceptance.
|
|
"
|
|
::= { bmFuncResMeasure 2 }
|
|
|
|
bmFuncResMeasureManualResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
resNoManualResult(1),
|
|
resManualProcessing(2),
|
|
resManualComplete(3),
|
|
resManualReject(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Get this oid to confirm the last manual command result."
|
|
::= { bmFuncResMeasure 3 }
|
|
|
|
bmFuncResMeasureLastUpdate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When resistance measurement complete either by auto or manual,
|
|
this oid will update to the last update time."
|
|
::= { bmFuncResMeasure 4 }
|
|
|
|
bmFuncEqualEnable OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery voltage equalization configuration."
|
|
::= { bmFuncEqual 1 }
|
|
|
|
bmFuncEqualActiveCond OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Volatge equalization will active when the voltage difference larger than this value, unit in 10mV."
|
|
::= { bmFuncEqual 2 }
|
|
|
|
bmFuncEqualStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
equalActive(1),
|
|
equalFailed(2),
|
|
equalNotActive(3),
|
|
equalNotSupport(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This oid shows the current equalization status."
|
|
::= { bmFuncEqual 3 }
|
|
|
|
bmFuncEqualStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This oid shows the last equalization start time."
|
|
::= { bmFuncEqual 4 }
|
|
|
|
bmFuncEqualElapseTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This oid shows the elapsed time since last equalization started."
|
|
::= { bmFuncEqual 5 }
|
|
|
|
-- Traps
|
|
-- Annotations are provided for Novell's NMS product
|
|
communicationLost TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: Communication with the UPS has been lost."
|
|
--#TYPE "CPS UPS: Communication lost"
|
|
--#SUMMARY "Communication with the UPS has been lost."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 1
|
|
|
|
upsOverload TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: The UPS has sensed an overload condition."
|
|
--#TYPE "CPS UPS: Overload"
|
|
--#SUMMARY "The UPS has sensed an overload condition."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 2
|
|
|
|
upsDiagnosticsFailed TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: The UPS battery test failed."
|
|
--#TYPE "CPS UPS: battery test failed"
|
|
--#SUMMARY "The UPS battery test failed."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 3
|
|
|
|
upsDischarged TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: The UPS has started a runtime estimation process."
|
|
--#TYPE "CPS UPS: batteries are discharged"
|
|
--#SUMMARY "The UPS has started a runtime estimation process."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 4
|
|
|
|
upsOnBattery TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: Utility power failed, transfer to backup mode."
|
|
--#TYPE "CPS UPS: The UPS is on battery"
|
|
--#SUMMARY "Utility power failed, transfer to backup mode."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 5
|
|
|
|
upsBoostOn TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS has enabled boost, low utility voltage."
|
|
--#TYPE "CPS UPS: Boost enable"
|
|
--#SUMMARY "The UPS has enabled boost, low utility voltage."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 6
|
|
|
|
lowBattery TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: The UPS battery capacity is low than threshold, soon to be exhausted."
|
|
--#TYPE "CPS UPS: Low battery"
|
|
--#SUMMARY "The UPS battery capacity is low than threshold, soon to be exhausted."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 7
|
|
|
|
communicationEstablished TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communication to the UPS has been established."
|
|
--#TYPE "CPS UPS: Communication established"
|
|
--#SUMMARY "Communication to the UPS has been established."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 8
|
|
|
|
powerRestored TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Utility power restored, return from backup mode."
|
|
--#TYPE "CPS UPS: Power restored"
|
|
--#SUMMARY "Utility power restored, return from backup mode."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 9
|
|
|
|
upsDiagnosticsPassed TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The UPS battery test passed."
|
|
--#TYPE "CPS UPS: Selftest passed"
|
|
--#SUMMARY "The UPS battery test passed."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 10
|
|
|
|
returnFromLowBattery TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The UPS has returned from a low battery condition."
|
|
--#TYPE "CPS UPS: Low battery condition cleared"
|
|
--#SUMMARY "The UPS has returned from a low battery condition."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 11
|
|
|
|
upsTurnedOff TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS has been turned off."
|
|
--#TYPE "CPS UPS: UPS turned off"
|
|
--#SUMMARY "The UPS has been turned off."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 12
|
|
|
|
upsSleeping TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS entered sleep mode. Output power will not be provided."
|
|
--#TYPE "CPS UPS: Entered sleep mode"
|
|
--#SUMMARY "The UPS entered sleep mode. Output power will not be provided."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 13
|
|
|
|
upsWokeUp TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS woke up from sleep mode. Output power is being provided."
|
|
--#TYPE "CPS UPS: UPS woke up"
|
|
--#SUMMARY "The UPS woke up from sleep mode. Output power is being provided."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 14
|
|
|
|
upsRebootStarted TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS started reboot sequence."
|
|
--#TYPE "CPS UPS: Starting reboot"
|
|
--#SUMMARY "The UPS started reboot sequence."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 15
|
|
|
|
upsOverTemp TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: The UPS inner temperature is too high."
|
|
--#TYPE "CPS UPS: UPS over temperature"
|
|
--#SUMMARY "The UPS inner temperature is too high."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 16
|
|
|
|
returnFromOverTemp TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The UPS over temperature condition cleared."
|
|
--#TYPE "CPS UPS: UPS over temperature cleared"
|
|
--#SUMMARY "The UPS over temperature condition cleared."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 17
|
|
|
|
upsBuckOn TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS has enabled buck, high utility voltage."
|
|
--#TYPE "CPS UPS: Buck enable"
|
|
--#SUMMARY "The UPS has enabled buck, high utility voltage."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 18
|
|
|
|
returnFromOverLoad TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The UPS has returned from an overload condition."
|
|
--#TYPE "CPS UPS: Returned from overload condition"
|
|
--#SUMMARY "The UPS has returned from an overload condition."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 19
|
|
|
|
returnFromDischarged TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The UPS runtime estimation completed."
|
|
--#TYPE "CPS UPS: Discharged condition cleared"
|
|
--#SUMMARY "The UPS runtime estimation completed."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 20
|
|
|
|
upsScheduleShutdown TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS has started its schedule shutdown sequence."
|
|
--#TYPE "CPS UPS: Schedule shutdown"
|
|
--#SUMMARY "The UPS has started its schedule shutdown sequence."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 21
|
|
|
|
upsEnterSleep TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS started sleep sequence."
|
|
--#TYPE "CPS UPS: Entered sleep mode sequence"
|
|
--#SUMMARY "The UPS started sleep sequence."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 22
|
|
|
|
upsChargerFailure TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The battery charger is abnormal."
|
|
--#TYPE "CPS UPS: The charger failed."
|
|
--#SUMMARY "The battery charger is abnormal."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 23
|
|
|
|
returnFromChargerFailure TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The charger returned from a failure condition."
|
|
--#TYPE "CPS UPS: The charger failure cleared"
|
|
--#SUMMARY "The charger returned from a failure condition."
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 24
|
|
|
|
upsTurnoffStarted TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS started turn off sequence."
|
|
--#TYPE "CPS UPS: Starting turn off"
|
|
--#SUMMARY "The UPS started its turn off sequence."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 25
|
|
|
|
upsTurnedOn TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS has been turned on."
|
|
--#TYPE "CPS UPS: UPS turned on"
|
|
--#SUMMARY "The UPS has been turned on."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 26
|
|
|
|
upsRemoteCommandFailed TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS remote command failed."
|
|
--#TYPE "CPS UPS: Command failed"
|
|
--#SUMMARY "The UPS remote command failed."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 27
|
|
|
|
upsLostRedundant TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: Not enough power redundancy modules."
|
|
--#TYPE "CPS UPS: lost redundancy"
|
|
--#SUMMARY "Not enough power redundancy modules."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 28
|
|
|
|
upsSignalClientShutdown TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: The UPS has signaled clients to shutdown."
|
|
--#TYPE "CPS UPS: Signal clients to shutdown"
|
|
--#SUMMARY "The UPS has signaled clients to shutdown."
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 29
|
|
|
|
upsEmergencyPowerOff TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"Emergency Power Off (EPO)"
|
|
--#TYPE "CPS UPS: Emergency Power Off (EPO)"
|
|
--#SUMMARY "Emergency Power Off (EPO)"
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 30
|
|
|
|
-- Outlet Traps
|
|
nclBankOn TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Non-Critical bank has been turned on."
|
|
--#TYPE "CPS UPS: NCL bank turned on."
|
|
--#SUMMARY "Non-Critical bank has been turned on"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 31
|
|
|
|
nclBankOff TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Non-Critical bank has been turned off."
|
|
--#TYPE "CPS UPS: NCL bank turned off."
|
|
--#SUMMARY "Non-Critical bank has been turned off"
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 32
|
|
|
|
upsCommandCancel TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: The cancel command has been executed."
|
|
--#TYPE "CPS UPS: Ups command canceled."
|
|
--#SUMMARY "The cancel command has been executed."
|
|
--#SEVERITY INFORMATION
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#STATE OPERATIONAL
|
|
::= 33
|
|
|
|
upsStartBatteryTest TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS has started a battery test process."
|
|
--#TYPE "CPS UPS: UPS selftest start."
|
|
--#SUMMARY "The UPS has started a battery test process."
|
|
--#SEVERITY INFORMATION
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#STATE OPERATIONAL
|
|
::= 34
|
|
|
|
upsRemainRuntimeLowThanThreshold TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS remaining runtime is lower than threshold."
|
|
--#TYPE "CPS UPS: Low remaining runtime."
|
|
--#SUMMARY "The UPS remaining runtime us lower than threshold."
|
|
--#SEVERITY INFORMATION
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#STATE OPERATIONAL
|
|
::= 35
|
|
|
|
nclBankStartScheduleOff TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: Non-Critial bank has started its schedule off sequence."
|
|
--#TYPE "CPS UPS: NCL bank started scheduled off sequence."
|
|
--#SUMMARY "Non-Critial bank has started its schedule off sequence."
|
|
--#SEVERITY INFORMATION
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#STATE OPERATIONAL
|
|
::= 36
|
|
|
|
upsEstimationAbort TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS runtime estimation aborted."
|
|
--#TYPE "CPS UPS: Runtime estimation aborted."
|
|
--#SUMMARY "The UPS runtime estimation aborted."
|
|
--#SEVERITY INFORMATION
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#STATE OPERATIONAL
|
|
::= 37
|
|
|
|
upsHardwareFault TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS hardware fault."
|
|
--#TYPE "CPS UPS: Hardware fault."
|
|
--#SUMMARY "The UPS hardware fault."
|
|
--#SEVERITY INFORMATION
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#STATE OPERATIONAL
|
|
::= 38
|
|
|
|
upsBatteryNotPresent TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: Battery is not present."
|
|
--#TYPE "CPS UPS: Battery is not present."
|
|
--#SUMMARY "Battery is not present."
|
|
--#SEVERITY INFORMATION
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#STATE OPERATIONAL
|
|
::= 39
|
|
|
|
-- OL extension event: Wiring Fault
|
|
upsWiringFault TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS wiring fault has been detected."
|
|
--#TYPE "The UPS wiring fault has been detected."
|
|
--#SUMMARY "The UPS wiring fault has been detected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 40
|
|
|
|
upsWiringFaultCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS wiring fault has been cleared."
|
|
--#TYPE "The UPS wiring fault has been cleared."
|
|
--#SUMMARY "The UPS wiring fault has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 41
|
|
|
|
upsEnterBypassMode TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS enters bypass mode."
|
|
--#TYPE "The UPS enters bypass mode"
|
|
--#SUMMARY "The UPS enters bypass mode."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 42
|
|
|
|
upsReturnFromBypassMode TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS leaves bypass mode."
|
|
--#TYPE "The UPS leaves bypass mode."
|
|
--#SUMMARY "The UPS leaves bypass mode."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 43
|
|
|
|
upsBypassOverload TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS bypass overload."
|
|
--#TYPE "The UPS bypass overload."
|
|
--#SUMMARY "The UPS bypass overload."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 44
|
|
|
|
upsBypassOverloadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS bypass overload has been cleared."
|
|
--#TYPE "The UPS bypass overload has been cleared."
|
|
--#SUMMARY "The UPS bypass overload has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 45
|
|
|
|
upsEnterECOMode TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS enters ECO mode."
|
|
--#TYPE "The UPS enters ECO mode"
|
|
--#SUMMARY "The UPS enters ECO mode."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 46
|
|
|
|
upsReturnFromECOMode TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The UPS leaves ECO mode."
|
|
--#TYPE "The UPS leaves ECO mode"
|
|
--#SUMMARY "The UPS leaves ECO mode."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 47
|
|
|
|
upsBatteryOverThreeYear TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: Battery has been 3 years from last Replacement."
|
|
--#TYPE "Battery has been 3 years from last Replacement."
|
|
--#SUMMARY "Battery has been 3 years from last Replacement."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 48
|
|
|
|
upsBatteryExpiration TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION "WARNING: The battery may not work well anymore."
|
|
--#TYPE "The battery may not work well anymore."
|
|
--#SUMMARY "The battery may not work well anymore."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 49
|
|
|
|
upsBatteryReplacement TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION "WARNING: The battery has been replaced."
|
|
--#TYPE "The battery has been replaced."
|
|
--#SUMMARY "The battery has been replaced."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 50
|
|
|
|
upsModuleInvertorAlarm TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION "WARNING: The UPS module invertor alarm."
|
|
--#TYPE "The UPS module invertor alarm."
|
|
--#SUMMARY "The UPS module invertor alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 51
|
|
|
|
upsModuleRectifierAlarm TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION "WARNING: The UPS module rectifier alarm."
|
|
--#TYPE "The UPS module rectifier alarm."
|
|
--#SUMMARY "The UPS module rectifier alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 52
|
|
|
|
upsModuleFanAlarm TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION "WARNING: The UPS module fan alarm."
|
|
--#TYPE "The UPS module fan alarm."
|
|
--#SUMMARY "The UPS module fan alarm."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 53
|
|
|
|
upsModuleManualShutdown TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION "WARNING: The UPS module manual shutdown."
|
|
--#TYPE "The UPS module manual shutdown."
|
|
--#SUMMARY "The UPS module manual shutdown."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 54
|
|
|
|
upsModuleOverload TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION "WARNING: The UPS module overload."
|
|
--#TYPE "The UPS module overload."
|
|
--#SUMMARY "The UPS module overload."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 55
|
|
|
|
upsFirmwareUpgradeStart TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION "WARNING: UPS firmware starts to update."
|
|
--#TYPE "UPS firmware starts to update."
|
|
--#SUMMARY "UPS firmware starts to update."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 56
|
|
|
|
upsFirmwareUpgradeEnd TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION "WARNING: UPS firmware update is over."
|
|
--#TYPE "UPS firmware update is over."
|
|
--#SUMMARY "UPS firmware update is over."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 57
|
|
|
|
upsRFC1628TrapOnBattery TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION "WARNING: RFC1628: UPS is on battery."
|
|
--#TYPE "RFC1628: UPS is on battery."
|
|
--#SUMMARY "RFC1628: UPS is on battery."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 58
|
|
|
|
upsRFC1628TrapTestCompleted TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION "WARNING: RFC1628: UPS test completed."
|
|
--#TYPE "RFC1628: UPS test completed."
|
|
--#SUMMARY "RFC1628: UPS test completed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 59
|
|
|
|
upsRFC1628TrapAlarmEntryAdded TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION "WARNING: RFC1628: Alarm entry added."
|
|
--#TYPE "RFC1628: Alarm entry added."
|
|
--#SUMMARY "RFC1628: Alarm entry added."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 60
|
|
|
|
-- Misc. Traps
|
|
failAuthViaHTTP TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: Login authorization failure via HTTP."
|
|
--#TYPE "CPS: HTTP authorization failure."
|
|
--#SUMMARY "Login authorization failure via HTTP."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 61
|
|
|
|
passwordChange TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: The password has been changed."
|
|
--#TYPE "CPS: Password changed."
|
|
--#SUMMARY "The password has been changed."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 62
|
|
|
|
failAuthViaConsole TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: Login authorization failure via Console."
|
|
--#TYPE "CPS: HTTP authorization failure."
|
|
--#SUMMARY "Login authorization failure via Console."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 63
|
|
|
|
configFileUpload TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: Configuration file uploaded."
|
|
--#TYPE "CPS: Configuration file uploaded."
|
|
--#SUMMARY "Configuration file uploaded."
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 64
|
|
|
|
adminLoginInfo TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: Administrator login."
|
|
--#TYPE "CPS: Administrator login information."
|
|
--#SUMMARY "Administrator login."
|
|
--#SEVERITY Information
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 65
|
|
|
|
adminLogoutInfo TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: Administrator logout."
|
|
--#TYPE "CPS: Administrator logout information."
|
|
--#SUMMARY "Administrator logout."
|
|
--#SEVERITY Information
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 66
|
|
|
|
deviceLoginInfo TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: Device login."
|
|
--#TYPE "CPS: Device user login information."
|
|
--#SUMMARY "Device user login from IP source."
|
|
--#SEVERITY Information
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 67
|
|
|
|
deviceLogoutInfo TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: Device logout."
|
|
--#TYPE "CPS: Device user logout information."
|
|
--#SUMMARY "Device user logout from IP source."
|
|
--#SEVERITY Information
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 68
|
|
|
|
configurationChanged TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATION: Configuration has been changed."
|
|
--#TYPE "CPS: Configuration changed."
|
|
--#SUMMARY "Configuration has been changed."
|
|
--#SEVERITY Information
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 69
|
|
|
|
clientRegistered TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"Information: PowerPanel client has been registered."
|
|
--#TYPE "CPS: PowerPanel client has been registered."
|
|
--#SUMMARY "PowerPanel client has been registered."
|
|
--#SEVERITY Information
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 70
|
|
|
|
clientRemoved TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"Information: PowerPanel client has been removed."
|
|
--#TYPE "CPS: Device user logout information."
|
|
--#SUMMARY "PowerPanel client has been registered."
|
|
--#SEVERITY Information
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
testEvent TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"Information: Test Event."
|
|
--#TYPE "CPS: This is test message."
|
|
--#SUMMARY "This is test message."
|
|
--#SEVERITY Information
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
outletUserLoginInfo TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"Information: Outlet User login."
|
|
--#TYPE "CPS: Outlet user login information."
|
|
--#SUMMARY "Outlet user login from IP source."
|
|
--#SEVERITY Information
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
outletUserLogoutInfo TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { mtrapinfoString }
|
|
DESCRIPTION
|
|
"Information: Outlet User logout."
|
|
--#TYPE "CPS: Outlet user logout information."
|
|
--#SUMMARY "Outlet user logout from IP source."
|
|
--#SEVERITY Information
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
-- ePDU. Traps
|
|
|
|
ePDUCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Communication with a Rack PDU has been established.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "A Rack PDU: Communication established."
|
|
--#SUMMARY "Communication with a Rack PDU established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 100
|
|
|
|
ePDUCommunicationLost TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: Communication with a Rack PDU has been lost.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "A Rack PDU: Communication lost."
|
|
--#SUMMARY "Communication with a Rack PDU has been lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 101
|
|
|
|
ePDUOutletOn TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDUOutletControlIndex, ePDUOutletControlOutletName,
|
|
mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on a Switched Rack PDU has turned on.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "A Switched Rack PDU: An outlet has turned on."
|
|
--#SUMMARY "An outlet on a Switched Rack PDU has turned on."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 102
|
|
|
|
ePDUOutletOff TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDUOutletControlIndex, ePDUOutletControlOutletName,
|
|
mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on a Switched Rack PDU has turned off.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "A Switched Rack PDU: An outlet has turned off."
|
|
--#SUMMARY "An outlet on a Switched Rack PDU has turned off."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 103
|
|
|
|
ePDUDeviceConfigChange TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A device configuration change has been made on a
|
|
Rack PDU.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "CPS Rack PDU: Device configuration change made."
|
|
--#SUMMARY "Device configuration change has been made on a Rack PDU."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 104
|
|
|
|
ePDUOutletConfigChange TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDUOutletControlIndex, ePDUOutletControlOutletName,
|
|
mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet configuration change has been made on a
|
|
Switched Rack PDU.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "CPS Switched Rack PDU: Outlet configuration change made."
|
|
--#SUMMARY "Outlet configuration change has been made on a Switched Rack PDU."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 105
|
|
|
|
ePDULowLoad TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusPhaseNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: A Rack PDU has violated the low load threshold.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "CPS Rack PDU: Violation of low load threshold."
|
|
--#SUMMARY "A Rack PDU has violated the low load threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 106
|
|
|
|
ePDULowLoadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusPhaseNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The low load condition on a Rack PDU has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "CPS Rack PDU: Low load condition cleared."
|
|
--#SUMMARY "The low load condition on a Rack PDU has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 107
|
|
|
|
ePDUNearOverload TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusPhaseNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: A Rack PDU is near an overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "CPS Rack PDU: Near an overload condition."
|
|
--#SUMMARY "A Rack PDU is near an overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 108
|
|
|
|
ePDUNearOverloadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusPhaseNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The near overload condition on a Rack PDU has
|
|
been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "CPS Rack PDU: Near overload condition has cleared."
|
|
--#SUMMARY "Rack PDU near overload condition has cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 109
|
|
|
|
ePDUOverload TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusPhaseNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: A Rack PDU is in an overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "CPS Rack PDU: Overload condition."
|
|
--#SUMMARY "A Rack PDU is in an overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
ePDUOverloadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusPhaseNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The overload condition on a Rack PDU has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "CPS Rack PDU: Overload condition has cleared."
|
|
--#SUMMARY "The overload condition on a Rack PDU has cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 111
|
|
|
|
ePDUDelayOutletOnCommand TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDUOutletControlIndex, ePDUOutletControlOutletName,
|
|
mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on a Switched Rack PDU has been assigned to turn on.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "A Switched Rack PDU: An outlet has been assigned to turn on."
|
|
--#SUMMARY "An outlet on a Switched Rack PDU has been assigned to turn on."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 112
|
|
|
|
ePDUDelayOutletOffCommand TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDUOutletControlIndex, ePDUOutletControlOutletName,
|
|
mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on a Switched Rack PDU has been assigned to turn off.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "A Switched Rack PDU: An outlet has been assigned to turn off."
|
|
--#SUMMARY "An outlet on a Switched Rack PDU has been assigned to turn off."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 113
|
|
|
|
ePDUDelayOutletRebootCommand TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDUOutletControlIndex, ePDUOutletControlOutletName,
|
|
mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on a Switched Rack PDU has been assigned to reboot.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "A Switched Rack PDU: An outlet has been assigned to reboot."
|
|
--#SUMMARY "An outlet on a Switched Rack PDU has been assigned to reboot."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 114
|
|
|
|
ePDUCancelPendingCommand TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDUOutletControlIndex, ePDUOutletControlOutletName,
|
|
mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A cancel pending command has been made on a
|
|
Switched Rack PDU.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number (0 indicates all outlets).
|
|
The fourth argument is the outlet name (or device name if all outlets)."
|
|
--#TYPE "A Switched Rack PDU: Cancel Pending Command made."
|
|
--#SUMMARY "A Cancel Pending Command has been made on a Switched Rack PDU."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 115
|
|
|
|
|
|
ePDULineUndervoltage TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusPhaseNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: Utility Line Undervoltage
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "A Rack PDU: Utility Line Undervoltage."
|
|
--#SUMMARY "Utility Line Undervoltage."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 116
|
|
|
|
ePDULineUndervoltageCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusPhaseNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Utility Line Undervoltage Cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "A Rack PDU: Utility Line Undervoltage Cleared."
|
|
--#SUMMARY "Utility Line Undervoltage Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 117
|
|
|
|
ePDULineOvervoltage TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusPhaseNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: Utility Line Overvoltage.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "CPS PDU: Utility Line Overvoltage."
|
|
--#SUMMARY "Utility Line Overvoltage."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 118
|
|
|
|
ePDULineOvervoltageCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusPhaseNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Utility Line Overvoltage Cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#TYPE "CPS PDU: Utility Line Overvoltage Cleared."
|
|
--#SUMMARY "Utility Line Overvoltage Cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 119
|
|
|
|
|
|
ePDUPowerSupply1Fail TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: Power Supply 1 on Rack PDU is in FAIL state.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "A Rack PDU: Power Supply 1 is in FAIL state."
|
|
--#SUMMARY "Power Supply 1 on Rack PDU is in FAIL state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 120
|
|
|
|
ePDUPowerSupply1Ok TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Power Supply 1 on Rack PDU is operating normally.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "A Rack PDU: Power Supply 1 is operating normally."
|
|
--#SUMMARY "Power Supply 1 on Rack PDU is operating normally."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 121
|
|
|
|
ePDUPowerSupply2Fail TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: Power Supply 2 on Rack PDU is in FAIL state.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "A Rack PDU: Power Supply 2 is in FAIL state."
|
|
--#SUMMARY "Power Supply 2 on Rack PDU is in FAIL state."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 122
|
|
|
|
ePDUPowerSupply2Ok TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Power Supply 2 on Rack PDU is operating normally.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "A Rack PDU: Power Supply 2 is operating normally."
|
|
--#SUMMARY "Power Supply 2 on Rack PDU is operating normally."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 123
|
|
|
|
ePDUBankLowLoad TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusBankNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: A Rack PDU bank has violated the low load threshold.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank number."
|
|
--#TYPE "CPS Rack PDU: Bank violation of low load threshold."
|
|
--#SUMMARY "A Rack PDU bank has violated the low load threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 124
|
|
|
|
ePDUBankLowLoadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusBankNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The low load condition on a Rack PDU bank has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank number."
|
|
--#TYPE "CPS Rack PDU: Bank Low load condition cleared."
|
|
--#SUMMARY "The low load condition on a Rack PDU bank has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 125
|
|
|
|
ePDUBankNearOverload TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusBankNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: A Rack PDU bank is near an overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank number."
|
|
--#TYPE "CPS Rack PDU: Bank near an overload condition."
|
|
--#SUMMARY "A Rack PDU bank is near an overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 126
|
|
|
|
ePDUBankNearOverloadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusBankNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The near overload condition on a Rack PDU bank has
|
|
been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase/bank number."
|
|
--#TYPE "CPS Rack PDU: Bank near overload condition has cleared."
|
|
--#SUMMARY "Rack PDU bank near overload condition has cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 127
|
|
|
|
ePDUBankOverload TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusBankNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: A Rack PDU bank is in an overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank number."
|
|
--#TYPE "CPS Rack PDU: Bank overload condition."
|
|
--#SUMMARY "A Rack PDU bank is in an overload condition."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY SEVERE
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE DEGRADED
|
|
::= 128
|
|
|
|
ePDUBankOverloadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
ePDULoadStatusBankNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The overload condition on a Rack PDU bank has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank number."
|
|
--#TYPE "CPS Rack PDU: Bank overload condition has cleared."
|
|
--#SUMMARY "The bank overload condition on a Rack PDU has cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 129
|
|
|
|
ePDUComponentCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Component communication lost has been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "CPS Rack PDU: Component communication lost has been cleared."
|
|
--#SUMMARY "Component communication lost has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 130
|
|
|
|
ePDUComponentCommunicationLost TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,
|
|
mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: Component communication lost.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#TYPE "CPS Rack PDU: Component communication lost."
|
|
--#SUMMARY "Component communication lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 131
|
|
|
|
ePDUOutletLowLoad TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,ePDUOutletConfigMonitoredNumber,
|
|
ePDUOutletConfigMonitoredName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: A Rack PDU has violated the outlet low load threshold.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number.
|
|
The fourth argument is the outlet name."
|
|
::= 132
|
|
|
|
ePDUOutletLowLoadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,ePDUOutletConfigMonitoredNumber,
|
|
ePDUOutletConfigMonitoredName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The outlet low load condition on a Rack PDU has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number.
|
|
The fourth argument is the outlet name."
|
|
::= 133
|
|
|
|
ePDUOutletNearOverload TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,ePDUOutletConfigMonitoredNumber,
|
|
ePDUOutletConfigMonitoredName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: A Rack PDU is near an outlet overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number.
|
|
The fourth argument is the outlet name."
|
|
::= 134
|
|
|
|
ePDUOutletNearOverloadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,ePDUOutletConfigMonitoredNumber,
|
|
ePDUOutletConfigMonitoredName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The outlet near overload condition on a Rack PDU has
|
|
been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number.
|
|
The fourth argument is the outlet name."
|
|
::= 135
|
|
|
|
ePDUOutletOverload TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,ePDUOutletConfigMonitoredNumber,
|
|
ePDUOutletConfigMonitoredName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"SEVERE: A Rack PDU is in an overload condition.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number.
|
|
The fourth argument is the outlet name."
|
|
::= 136
|
|
|
|
ePDUOutletOverloadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDUIdentSerialNumber, ePDUIdentName,ePDUOutletConfigMonitoredNumber,
|
|
ePDUOutletConfigMonitoredName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The outlet overload condition on a Rack PDU has been
|
|
cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number.
|
|
The fourth argument is the outlet name."
|
|
::= 137
|
|
|
|
-- Environment Traps
|
|
envHighTemperatureViolation TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation, envirTemperature }
|
|
DESCRIPTION
|
|
"WARNING: The environment high temperature threshold has been violated."
|
|
--#TYPE "CPS Environment Viewer: OverTemperature"
|
|
--#SUMMARY "The environment high temperature threshold has been violated."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 200
|
|
|
|
envHighTemperatureBack TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation, envirTemperature }
|
|
DESCRIPTION
|
|
"INFORMATION: The environment temperature returned from high value."
|
|
--#TYPE "CPS Environment Viewer: OverTemperature Returned"
|
|
--#SUMMARY "The environment temperature returned from high value."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 201
|
|
|
|
envLowTemperatureViolation TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation, envirTemperature }
|
|
DESCRIPTION
|
|
"WARNING: The environment low temperature threshold has been violated."
|
|
--#TYPE "CPS Environment Viewer: UnderTemperature"
|
|
--#SUMMARY "The environment low temperature threshold has been violated."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 202
|
|
|
|
envLowTempBack TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation, envirTemperature }
|
|
DESCRIPTION
|
|
"INFORMATION: The environment temperature returned from low value."
|
|
--#TYPE "CPS Environment Viewer: UnderTemperature Returned"
|
|
--#SUMMARY "The environment temperature returned from low value."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 203
|
|
|
|
envHighHumidityViolation TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation, envirHumidity }
|
|
DESCRIPTION
|
|
"WARNING: The environment high humidity threshold has been violated."
|
|
--#TYPE "CPS Environment Viewer: OverHumidity"
|
|
--#SUMMARY "The environment high humidity threshold has been violated."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 204
|
|
|
|
envHighHumidityBack TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation, envirHumidity }
|
|
DESCRIPTION
|
|
"INFORMATION: The environment humidity return from high value."
|
|
--#TYPE "CPS Environment Viewer: OverHumidity Returned"
|
|
--#SUMMARY "The environment humidity return from high value."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 205
|
|
|
|
envLowHumidityViolation TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation, envirHumidity }
|
|
DESCRIPTION
|
|
"WARNING: The environment low humidity threshold has been violated."
|
|
--#TYPE "CPS Environment Viewer: UnderHumidity"
|
|
--#SUMMARY "The environment low humidity threshold has been violated."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 206
|
|
|
|
envLowHumdBack TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation, envirHumidity }
|
|
DESCRIPTION
|
|
"INFORMATION: The environment humidity return from low value."
|
|
--#TYPE "CPS Environment Viewer: UnderHumidity Returned"
|
|
--#SUMMARY "The environment humidity return from low value."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 207
|
|
|
|
envDryContactAbnormal TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation,
|
|
envirContactIndex, envirContactName }
|
|
DESCRIPTION
|
|
"INFORMATION: The Contact is abnormal."
|
|
--#TYPE "CPS Environment Viewer: Contact Abnormal"
|
|
--#SUMMARY "The Contact is abnormal."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 208
|
|
|
|
envDryContactNormal TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation,
|
|
envirContactIndex, envirContactName }
|
|
DESCRIPTION
|
|
"INFORMATION: The Contact has returned from abnormal."
|
|
--#TYPE "CPS Environment Viewer: Contact Normal"
|
|
--#SUMMARY "The Contact has returned from abnormal."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 209
|
|
|
|
envConntected TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation }
|
|
DESCRIPTION
|
|
"INFORMATION: The Environment Sensor has been connected."
|
|
--#TYPE "CPS Environment Viewer: The Environment Sensor has been connected"
|
|
--#SUMMARY "The Environment Sensor has been connected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 210
|
|
|
|
envDisconntected TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation }
|
|
DESCRIPTION
|
|
"INFORMATION: The Environment Sensor has been disconnected."
|
|
--#TYPE "CPS Environment Viewer: The Environment Sensor has been disconnected"
|
|
--#SUMMARY "The Environment Sensor has been disconnected."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 211
|
|
|
|
envRateOfTemperatureChangeAbnormal TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation, envirTemperature }
|
|
DESCRIPTION
|
|
"INFORMATION: The rate of temperature change is abnormal."
|
|
--#TYPE "CPS Environment Viewer: The rate of temperature change is abnormal"
|
|
--#SUMMARY "The rate of temperature change is abnormal."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 212
|
|
|
|
envRateOfHumdChangeAbnormal TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { envirIdentName, envirIdentLocation, envirHumidity }
|
|
DESCRIPTION
|
|
"INFORMATION: The rate of humidity change is abnormal."
|
|
--#TYPE "CPS Environment Viewer: The rate of humidity change is abnormal"
|
|
--#SUMMARY "The rate of humidity change is abnormal."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE NONOPERATIONAL
|
|
::= 213
|
|
|
|
atsSwitchSource TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusSelectedSource, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: ATS has switched source.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the selected source."
|
|
--#TYPE "CPS ATS: ATS has switched source."
|
|
--#SUMMARY "ATS has switched source."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 301
|
|
|
|
atsSourceFault TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: Source fault occurs.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the source name."
|
|
--#TYPE "CPS ATS: Source fault occurs."
|
|
--#SUMMARY "Source fault occurs."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 302
|
|
|
|
atsSourceFaultCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Source fault has been cleared.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the source name."
|
|
--#TYPE "CPS ATS: Source fault has been cleared."
|
|
--#SUMMARY "Source fault has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 303
|
|
|
|
atsRedundancyFail TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: Redundancy fails.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the source name."
|
|
--#TYPE "CPS ATS: Redundancy fails."
|
|
--#SUMMARY "Redundancy fails."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 304
|
|
|
|
atsRedundancyRestored TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Redundancy has been restored.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the source name."
|
|
--#TYPE "CPS ATS: Redundancy has been restored."
|
|
--#SUMMARY "Redundancy has been restored."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 305
|
|
|
|
atsInputHighVoltage TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputVoltage, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The upper voltage limit has been crossed.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the source name.
|
|
The fourth argument is the phase voltage."
|
|
--#TYPE "CPS ATS: The upper voltage limit has been crossed."
|
|
--#SUMMARY "The upper voltage limit has been crossed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 306
|
|
|
|
atsInputHighVoltageCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputVoltage, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The upper voltage condition has been cleared.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the source name.
|
|
The fourth argument is the phase voltage."
|
|
--#TYPE "CPS ATS: The upper voltage condition has been cleared."
|
|
--#SUMMARY "The upper voltage condition has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 307
|
|
|
|
atsInputLowVoltage TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputVoltage, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The lower voltage limit has been crossed.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the source name.
|
|
The fourth argument is the phase voltage."
|
|
--#TYPE "CPS ATS: The lower voltage limit has been crossed."
|
|
--#SUMMARY "The lower voltage limit has been crossed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 308
|
|
|
|
atsInputLowVoltageCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputVoltage, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The lower voltage condition has been cleared.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the source name.
|
|
The fourth argument is the phase voltage."
|
|
--#TYPE "CPS ATS: The lower voltage condition has been cleared."
|
|
--#SUMMARY "The lower voltage condition has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 309
|
|
|
|
atsInputHighFrequency TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputFrequency, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The upper frequency limit has been crossed.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the source name.
|
|
The fourth argument is the input frequency."
|
|
--#TYPE "CPS ATS: The upper frequency limit has been crossed."
|
|
--#SUMMARY "The upper frequency limit has been crossed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 310
|
|
|
|
atsInputHighFrequencyCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputFrequency, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The upper frequency condition has been cleared.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the source name.
|
|
The fourth argument is the input frequency."
|
|
--#TYPE "CPS ATS: The upper frequency condition has been cleared."
|
|
--#SUMMARY "The upper frequency condition has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 311
|
|
|
|
atsInputLowFrequency TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputFrequency, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The lower frequency limit has been crossed.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the source name.
|
|
The fourth argument is the input frequency."
|
|
--#TYPE "CPS ATS: The lower frequency limit has been crossed."
|
|
--#SUMMARY "The lower frequency limit has been crossed."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 312
|
|
|
|
atsInputLowFrequencyCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusInputName, atsStatusInputFrequency, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The lower frequency condition has been cleared.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the source name.
|
|
The fourth argument is the input frequency."
|
|
--#TYPE "CPS ATS: The lower frequency condition has been cleared."
|
|
--#SUMMARY "The lower frequency condition has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 313
|
|
|
|
atsCommunicationLost TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"MAJOR: ATS communication lost.
|
|
The first argument is the device name.
|
|
The second argument is the serial number."
|
|
--#TYPE "CPS ATS: ATS communication lost."
|
|
--#SUMMARY "ATS communication lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 314
|
|
|
|
atsCommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: ATS communication has been established.
|
|
The first argument is the device name.
|
|
The second argument is the serial number."
|
|
--#TYPE "CPS ATS: ATS communication has been established."
|
|
--#SUMMARY "ATS communication has been established."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 315
|
|
|
|
atsLCDCommunicationLost TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: LCD communication lost.
|
|
The first argument is the device name.
|
|
The second argument is the serial number."
|
|
--#TYPE "CPS ATS: LCD communication lost."
|
|
--#SUMMARY "LCD communication lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 316
|
|
|
|
atsLCDCommunicationLostCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: LCD communication lost has been cleared.
|
|
The first argument is the device name.
|
|
The second argument is the serial number."
|
|
--#TYPE "CPS ATS: LCD communication lost has been cleared."
|
|
--#SUMMARY "LCD communication lost has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 317
|
|
|
|
atsDB9CommunicationLost TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: DB9 communication lost.
|
|
The first argument is the device name.
|
|
The second argument is the serial number."
|
|
--#TYPE "CPS ATS: DB9 communication lost."
|
|
--#SUMMARY "DB9 communication lost."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 318
|
|
|
|
atsDB9CommunicationLostCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: DB9 communication lost has been cleared.
|
|
The first argument is the device name.
|
|
The second argument is the serial number."
|
|
--#TYPE "CPS ATS: DB9 communication lost has been cleared."
|
|
--#SUMMARY "DB9 communication lost has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 319
|
|
|
|
atsPowerSupplyFault TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusPowerSupplyInputSource, mtrapinfoString }
|
|
DESCRIPTION
|
|
"CRITICAL: Power supply failure.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the input source of the power supply."
|
|
--#TYPE "CPS ATS: Power supply failure."
|
|
--#SUMMARY "Power supply failure."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 320
|
|
|
|
atsPowerSupplyFaultCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, atsStatusPowerSupplyInputSource, mtrapinfoString }
|
|
DESCRIPTION
|
|
"CRITICAL: Power supply failure.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the input source of the power supply."
|
|
--#TYPE "CPS ATS: Power supply failure has been cleared."
|
|
--#SUMMARY "Power supply failure has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 321
|
|
|
|
atsDevHardwareFault TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"CRITICAL: Device hardware failure.
|
|
The first argument is the device name.
|
|
The second argument is the serial number."
|
|
--#TYPE "CPS ATS: Device hardware failure."
|
|
--#SUMMARY "Device hardware failure."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 322
|
|
|
|
atsDevHardwareFaultCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Device hardware failure has been cleared.
|
|
The first argument is the device name.
|
|
The second argument is the serial number."
|
|
--#TYPE "CPS ATS: Device hardware failure has been cleared."
|
|
--#SUMMARY "Device hardware failure has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 323
|
|
|
|
atsSourceConfigChanged TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A source configuration change has been made.
|
|
The first argument is the device name.
|
|
The second argument is the serial number."
|
|
--#TYPE "CPS ATS: A source configuration change has been made."
|
|
--#SUMMARY "A source configuration change has been made."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 324
|
|
|
|
atsDeviceConfigChanged TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A device configuration change has been made.
|
|
The first argument is the device name.
|
|
The second argument is the serial number."
|
|
--#TYPE "CPS ATS: A device configuration change has been made."
|
|
--#SUMMARY "A device configuration change has been made."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 325
|
|
|
|
atsOutletConfigChanged TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A outlet configuration change has been made.
|
|
The first argument is the device name.
|
|
The second argument is the serial number."
|
|
--#TYPE "CPS ATS: A outlet configuration change has been made."
|
|
--#SUMMARY "A outlet configuration change has been made."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 326
|
|
|
|
atsEventCountsCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Event counts has been cleared.
|
|
The first argument is the device name.
|
|
The second argument is the serial number."
|
|
--#TYPE "CPS ATS: Event counts has been cleared."
|
|
--#SUMMARY "Event counts has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 327
|
|
|
|
atsOverload TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber,
|
|
atsLoadStatusBankTableIndex, atsLoadStatusBankLoad, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The load has exceeded overload threshold.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the bank number.
|
|
The third argument is the load."
|
|
--#TYPE "CPS ATS: The load has exceeded overload threshold."
|
|
--#SUMMARY "The load has exceeded overload threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 328
|
|
|
|
atsOverloadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber,
|
|
atsLoadStatusBankTableIndex, atsLoadStatusBankLoad, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The overload condition has been cleared.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the bank number.
|
|
The third argument is the load."
|
|
--#TYPE "CPS ATS: The overload condition has been cleared."
|
|
--#SUMMARY "The overload condition has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 329
|
|
|
|
atsNearOverload TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber,
|
|
atsLoadStatusBankTableIndex, atsLoadStatusBankLoad, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The load has exceeded near overload threshold.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the bank number.
|
|
The third argument is the load."
|
|
--#TYPE "CPS ATS: The load has exceeded near overload threshold."
|
|
--#SUMMARY "The load has exceeded near overload threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 330
|
|
|
|
atsNearOverloadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber,
|
|
atsLoadStatusBankTableIndex, atsLoadStatusBankLoad, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The near overload condition has beed cleared.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the bank number.
|
|
The third argument is the load."
|
|
--#TYPE "CPS ATS: The near overload condition has beed cleared."
|
|
--#SUMMARY "The near overload condition has beed cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 331
|
|
|
|
atsLowLoad TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber,
|
|
atsLoadStatusBankTableIndex, atsLoadStatusBankLoad, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: The load has been lower than low load threshold.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the bank number.
|
|
The third argument is the load."
|
|
--#TYPE "CPS ATS: The load has been lower than low load threshold."
|
|
--#SUMMARY "The load has been lower than low load threshold."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 332
|
|
|
|
atsLowLoadCleared TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber,
|
|
atsLoadStatusBankTableIndex, atsLoadStatusBankLoad, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: The low load condition has been cleared.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the bank number.
|
|
The third argument is the load."
|
|
--#TYPE "CPS ATS: The low load condition has been cleared."
|
|
--#SUMMARY "The low load condition has been cleared."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 333
|
|
|
|
|
|
atsOutletOnCommand TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber,
|
|
atsOutletCtrlTableIndex, atsOutletCtrlOutletName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on ATS has been assigned to turn on.
|
|
The first argument is the device name.
|
|
The second argument is the serial number.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "CPS ATS: An outlet on ATS has been assigned to turn on."
|
|
--#SUMMARY "An outlet on ATS has been assigned to turn on."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 334
|
|
|
|
atsOutletOffCommand TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber,
|
|
atsOutletCtrlTableIndex, atsOutletCtrlOutletName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on ATS has been assigned to turn off.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "CPS ATS: An outlet on ATS has been assigned to turn off."
|
|
--#SUMMARY "An outlet on ATS has been assigned to turn off."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 335
|
|
|
|
atsOutletRebootCommand TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber,
|
|
atsOutletCtrlTableIndex, atsOutletCtrlOutletName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on ATS has been assigned to reboot.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "CPS ATS: An outlet on ATS has been assigned to reboot."
|
|
--#SUMMARY "An outlet on ATS has been assigned to reboot."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 336
|
|
|
|
atsCancelPendingCommand TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber,
|
|
atsOutletCtrlTableIndex, atsOutletCtrlOutletName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A cancel pending command has been made on ATS.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number (0 indicates all outlets).
|
|
The fourth argument is the outlet name (or device name if all outlets)."
|
|
--#TYPE "CPS ATS: A cancel pending command has been made on ATS."
|
|
--#SUMMARY "A cancel pending command has been made on ATS."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 337
|
|
|
|
atsOutletOn TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber,
|
|
atsOutletCtrlTableIndex, atsOutletCtrlOutletName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on ATS has turned on.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "CPS ATS: An outlet on ATS has turned on."
|
|
--#SUMMARY "An outlet on ATS has turned on."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 338
|
|
|
|
atsOutletOff TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { atsIdentName, atsIdentSerialNumber,
|
|
atsOutletCtrlTableIndex, atsOutletCtrlOutletName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet on ATS has turned off.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet index number.
|
|
The fourth argument is the outlet name."
|
|
--#TYPE "CPS ATS: An outlet on ATS has turned off."
|
|
--#SUMMARY "An outlet on ATS has turned off."
|
|
--#ARGUMENTS { }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#HELP ""
|
|
--#HELPTAG 0
|
|
--#STATE OPERATIONAL
|
|
::= 339
|
|
|
|
-- ePDU2Traps
|
|
pduDeviceEvent TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
|
|
ePDU2DeviceConfigIndex, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU device event has been happened.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the device table index."
|
|
::= 400
|
|
|
|
pduDeviceAlarm TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
|
|
ePDU2DeviceStatusIndex, mtrapinfoString }
|
|
DESCRIPTION
|
|
"Alarm: A PDU device alarm has been detected.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the device table index."
|
|
::= 401
|
|
|
|
pduDeviceAlarmClear TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
|
|
ePDU2DeviceStatusIndex, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU device alarm has been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the device table index."
|
|
::= 402
|
|
|
|
pduPhaseEvent TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
|
|
ePDU2PhaseConfigIndex, ePDU2PhaseConfigNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU phase event has been happened.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase table index.
|
|
The foutrh argument is the phase number."
|
|
::= 403
|
|
|
|
pduPhaseAlarm TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
|
|
ePDU2PhaseStatusIndex, ePDU2PhaseStatusNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"Alarm: A PDU phase alarm has been detected.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase table index.
|
|
The foutrh argument is the phase number."
|
|
::= 404
|
|
|
|
pduPhaseAlarmClear TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
|
|
ePDU2PhaseStatusIndex, ePDU2PhaseStatusNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU phase alarm has been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase table index.
|
|
The foutrh argument is the phase number."
|
|
::= 405
|
|
|
|
pduBankEvent TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
|
|
ePDU2BankConfigIndex, ePDU2BankConfigNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU bank event has been happened.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank table index.
|
|
The foutrh argument is the bank number."
|
|
::= 406
|
|
|
|
pduBankAlarm TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
|
|
ePDU2BankStatusIndex, ePDU2BankStatusNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"Alarm: A PDU bank alarm has been detected.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank table index.
|
|
The foutrh argument is the bank number."
|
|
::= 407
|
|
|
|
pduBankAlarmClear TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName,
|
|
ePDU2BankStatusIndex, ePDU2BankStatusNumber, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU bank alarm has been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the bank table index.
|
|
The foutrh argument is the bank number."
|
|
::= 408
|
|
|
|
pduOutletSwitchedEvent TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2OutletSwitchedControlIndex,
|
|
ePDU2OutletSwitchedControlNumber, ePDU2OutletSwitchedControlName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU switched outlet event has been happened.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet table index.
|
|
The foutrh argument is the outlet number.
|
|
The fifth argument is the outlet name."
|
|
::= 409
|
|
|
|
pduOutletSwitchedAlarm TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2OutletSwitchedStatusIndex,
|
|
ePDU2OutletSwitchedStatusNumber, ePDU2OutletSwitchedStatusName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"Alarm: A PDU switched outlet alarm has been detected.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet table index.
|
|
The foutrh argument is the outlet number.
|
|
The fifth argument is the outlet name."
|
|
::= 410
|
|
|
|
pduOutletSwitchedAlarmClear TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2OutletSwitchedStatusIndex,
|
|
ePDU2OutletSwitchedStatusNumber, ePDU2OutletSwitchedStatusName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU switched outlet alarm has been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet table index.
|
|
The foutrh argument is the outlet number.
|
|
The fifth argument is the outlet name."
|
|
::= 411
|
|
|
|
pduOutletMeteredEvent TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2OutletMeteredConfigIndex,
|
|
ePDU2OutletMeteredConfigNumber, ePDU2OutletMeteredConfigName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU metered outlet event has been happened.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet table index.
|
|
The foutrh argument is the outlet number.
|
|
The fifth argument is the outlet name."
|
|
::= 412
|
|
|
|
pduOutletMeteredAlarm TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2OutletMeteredStatusIndex,
|
|
ePDU2OutletMeteredStatusNumber, ePDU2OutletMeteredStatusName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"Alarm: A PDU metered outlet alarm has been detected.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet table index.
|
|
The foutrh argument is the outlet number.
|
|
The fifth argument is the outlet name."
|
|
::= 413
|
|
|
|
pduOutletMeteredAlarmClear TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2OutletMeteredStatusIndex,
|
|
ePDU2OutletMeteredStatusNumber, ePDU2OutletMeteredStatusName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU metered outlet alarm has been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet table index.
|
|
The foutrh argument is the outlet number.
|
|
The fifth argument is the outlet name."
|
|
::= 414
|
|
|
|
pduDaisyChainEvent TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2IdentIndex,
|
|
ePDU2IdentSerialNumber, ePDU2IdentName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU daisy-chain event has been happened.
|
|
The first argument is the host serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the event device table index.
|
|
The foutrh argument is the event device serial number.
|
|
The fifth argument is the event device name."
|
|
::= 415
|
|
|
|
pduDaisyChainAlarm TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2IdentIndex,
|
|
ePDU2IdentSerialNumber, ePDU2IdentName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"Alarm: A PDU daisy-chain alarm has been detected.
|
|
The first argument is the host serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the alarm device table index.
|
|
The foutrh argument is the alarm device serial number.
|
|
The fifth argument is the alarm device name."
|
|
::= 416
|
|
|
|
pduDaisyChainAlarmClear TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { ePDU2IdentSerialNumber, ePDU2IdentName, ePDU2IdentIndex,
|
|
ePDU2IdentSerialNumber, ePDU2IdentName, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A PDU daisy-chain alarm has been cleared.
|
|
The first argument is the host serial number.
|
|
The second argument is the host device name.
|
|
The third argument is the alarm device table index.
|
|
The foutrh argument is the alarm deice serial number.
|
|
The fifth argument is the alarm device name."
|
|
::= 417
|
|
|
|
bmSystemAlarm TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { bmIdentSerialNumber, bmIdentName, bmIdentLocation, mtrapinfoBmEventId, mtrapinfoString }
|
|
DESCRIPTION
|
|
"ALARM: System alarm occurance.
|
|
The first argument is the bm device serial number.
|
|
The second argument is the bm system identification name.
|
|
The third argument is the bm system location.
|
|
The fourth argument is the alarm event specific identifier.
|
|
The fifth argument is the trap information string."
|
|
::= 600
|
|
|
|
bmSystemWarning TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { bmIdentSerialNumber, bmIdentName, bmIdentLocation, mtrapinfoBmEventId, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: System warning occurance.
|
|
The first argument is the bm device serial number.
|
|
The second argument is the bm system identification name.
|
|
The third argument is the bm system location.
|
|
The fourth argument is the alarm event specific identifier.
|
|
The fifth argument is the trap information string."
|
|
::= 601
|
|
|
|
bmSystemInfo TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { bmIdentSerialNumber, bmIdentName, bmIdentLocation, mtrapinfoBmEventId, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFO: System information.
|
|
The first argument is the bm device serial number.
|
|
The second argument is the bm system identification name.
|
|
The third argument is the bm system location.
|
|
The fourth argument is the alarm event specific identifier.
|
|
The fifth argument is the trap information string."
|
|
::= 602
|
|
|
|
bmProbesAlarm TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { bmIdentSerialNumber, bmIdentName, bmIdentLocation, bmProbesStringIndex, bmProbesBattIndex, mtrapinfoBmEventId, mtrapinfoString }
|
|
DESCRIPTION
|
|
"ALARM: Probe alarm event.
|
|
The first argument is the bm device serial number.
|
|
The second argument is the bm system identification name.
|
|
The third argument is the bm system location.
|
|
The fourth argument is the string index the probe located.
|
|
The fifth argument is the battery index the probe located.
|
|
The sixth argument is the alarm event specific identifier.
|
|
The seventh argument is the trap information string."
|
|
::= 603
|
|
|
|
bmSProbesWarning TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { bmIdentSerialNumber, bmIdentName, bmIdentLocation, bmProbesStringIndex, bmProbesBattIndex, mtrapinfoBmEventId, mtrapinfoString }
|
|
DESCRIPTION
|
|
"WARNING: Probe warning event.
|
|
The first argument is the bm device serial number.
|
|
The second argument is the bm system identification name.
|
|
The third argument is the bm system location.
|
|
The fourth argument is the string index the probe located.
|
|
The fifth argument is the battery index the probe located.
|
|
The sixth argument is the alarm event specific identifier.
|
|
The seventh argument is the trap information string."
|
|
::= 604
|
|
|
|
bmProbesInfo TRAP-TYPE
|
|
ENTERPRISE cps
|
|
VARIABLES { bmIdentSerialNumber, bmIdentName, bmIdentLocation, bmProbesStringIndex, bmProbesBattIndex, mtrapinfoBmEventId, mtrapinfoString }
|
|
DESCRIPTION
|
|
"INFO: Probe information.
|
|
The first argument is the bm device serial number.
|
|
The second argument is the bm system identification name.
|
|
The third argument is the bm system location.
|
|
The fourth argument is the string index the probe located.
|
|
The fifth argument is the battery index the probe located.
|
|
The sixth argument is the alarm event specific identifier.
|
|
The seventh argument is the trap information string."
|
|
::= 605
|
|
|
|