-- SLE-DEVICE-MIB.my
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
-- Friday, March 18, 2016 at 15:23:50
--
SLE-DEVICE-MIB DEFINITIONS ::= BEGIN
IMPORTS
sleMgmt
FROM DASAN-SMI
SleControlStatusType, SleControlRequestResultType
FROM SLE-TC-MIB
OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
TimeTicks, IpAddress, Integer32, Unsigned32, Gauge32,
BITS, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI;
sleDevice MODULE-IDENTITY
LAST-UPDATED "200412100852Z" -- December 10, 2004 at 08:52 GMT
ORGANIZATION
"Organization."
CONTACT-INFO
"Contact-info."
DESCRIPTION
"Description."
::= { sleMgmt 2 }
--
-- Node definitions
--
sleDeviceBase OBJECT IDENTIFIER ::= { sleDevice 1 }
sleDeviceBaseInfo OBJECT IDENTIFIER ::= { sleDeviceBase 1 }
sleDeviceEthernetPortNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ethernet port."
::= { sleDeviceBaseInfo 1 }
sleDevicePowerNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of power module"
::= { sleDeviceBaseInfo 2 }
sleDeviceFanModuleNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of FAN module"
::= { sleDeviceBaseInfo 3 }
sleDeviceTemperatureNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of temperature sensor"
::= { sleDeviceBaseInfo 4 }
sleDeviceFanStartTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature value which begins to turn fan."
::= { sleDeviceBaseInfo 5 }
sleDeviceFanStopTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature value which stops fan."
::= { sleDeviceBaseInfo 6 }
sleDeviceJumboFrameStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The global jumbo-frame status.
2011/01/20 V5924CR only support this."
::= { sleDeviceBaseInfo 7 }
sleDeviceEnvironmentMonitoringStatus OBJECT-TYPE
SYNTAX INTEGER
{
notInstallAIU(0),
normalOpen(1),
normalClose(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm input mode of environment monitoring for AIU"
::= { sleDeviceBaseInfo 8 }
sleDeviceBaseControl OBJECT IDENTIFIER ::= { sleDeviceBase 2 }
sleDeviceControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setDeviceTemperatureThreshold(1),
setDeviceJumboFrameStatus(2),
setDeviceLEDTest(3),
setEnvironmentMonitoringStatus(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set an administrative state of FAN module"
::= { sleDeviceBaseControl 1 }
sleDeviceControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleDeviceBaseControl 2 }
sleDeviceControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleDeviceBaseControl 3 }
sleDeviceControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleDeviceBaseControl 4 }
sleDeviceControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleDeviceBaseControl 5 }
sleDeviceControlFanStartTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleDeviceBaseControl 6 }
sleDeviceControlFanStopTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleDeviceBaseControl 7 }
sleDeviceControlJumboFrameStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The global jumbo-frame status.
2011/01/20 V5924CR only support this."
::= { sleDeviceBaseControl 8 }
sleDeviceControlEnvironmentMonitoringStatus OBJECT-TYPE
SYNTAX INTEGER
{
normalOpen(1),
normalClose(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm input mode of environment monitoring for AIU"
::= { sleDeviceBaseControl 9 }
sleDeviceBaseNotification OBJECT IDENTIFIER ::= { sleDeviceBase 3 }
sleDeviceTemperatureThresholdChanged NOTIFICATION-TYPE
OBJECTS { sleDeviceFanStartTemperature, sleDeviceFanStopTemperature, sleDeviceControlRequest, sleDeviceControlTimeStamp, sleDeviceControlReqResult
}
STATUS current
DESCRIPTION
"Description."
::= { sleDeviceBaseNotification 1 }
sleDeviceJumboFrameChanged NOTIFICATION-TYPE
OBJECTS { sleDeviceControlRequest, sleDeviceControlTimeStamp, sleDeviceControlReqResult, sleDeviceControlJumboFrameStatus }
STATUS current
DESCRIPTION
"Description."
::= { sleDeviceBaseNotification 2 }
sleDeviceLEDTestChanged NOTIFICATION-TYPE
OBJECTS { sleDeviceControlRequest, sleDeviceControlTimeStamp, sleDeviceControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleDeviceBaseNotification 3 }
sleDeviceEnvironmentMonitoringStatusChanged NOTIFICATION-TYPE
OBJECTS { sleDeviceControlRequest, sleDeviceControlTimeStamp, sleDeviceControlReqResult, sleDeviceEnvironmentMonitoringStatus }
STATUS current
DESCRIPTION
"setEnvironmentMonitoringStatus "
::= { sleDeviceBaseNotification 4 }
sleEthernetPort OBJECT IDENTIFIER ::= { sleDevice 2 }
sleEthernetPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleEthernetPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPort 1 }
sleEthernetPortEntry OBJECT-TYPE
SYNTAX SleEthernetPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleEthernetPortIndex }
::= { sleEthernetPortTable 1 }
SleEthernetPortEntry ::=
SEQUENCE {
sleEthernetPortIndex
INTEGER,
sleEthernetPortPhyIndex
Integer32,
sleEthernetPortType
INTEGER,
sleEthernetPortAdminStatus
INTEGER,
sleEthernetPortOperStatus
INTEGER,
sleEthernetPortTransmissionRate
Integer32,
sleEthernetPortDuplexMode
INTEGER,
sleEthernetPortFlowControl
INTEGER,
sleEthernetPortNegotiationMode
INTEGER,
sleEthernetPortJumboFrameSize
Integer32,
sleEthernetPortSfpTransceiver
INTEGER,
sleEthernetPortSfpVendorName
OCTET STRING,
sleEthernetPortSfpVendorPartNumber
OCTET STRING,
sleEthernetPortSfpVendorRevision
OCTET STRING,
sleEthernetPortSfpVendorSerialNumber
OCTET STRING,
sleEthernetPortSfpDateCode
OCTET STRING,
sleEthernetPortPhysicalRemoteChassis
OCTET STRING,
sleEthernetPortPhysicalRemoteSlot
Integer32,
sleEthernetPortPhysicalRemotePort
Integer32,
sleEthernetPortPhysicalLinkDiscoveryMode
INTEGER,
sleEthernetPortSfpTransceiverType
INTEGER,
sleEthernetPortSfpTransceiverDetailType
INTEGER,
sleEthernetPortSlotIndex
Integer32,
sleEthernetPortSlotPortIndex
Integer32,
sleEthernetPortAdminTransmissionRate
Integer32,
sleEthernetPortAdminDuplexMode
INTEGER,
sleEthernetPortAdminFlowControl
INTEGER,
sleEthernetPortAdminNegotiationMode
INTEGER,
sleEthernetPortAdminReason
INTEGER,
sleEthernetPortLinkCheckTimer
Integer32,
sleEthernetPortLinkDebounceTime
Integer32,
sleEthernetPortCpuStatisticsLimitUnicast
Integer32,
sleEthernetPortCpuStatisticsLimitMulticast
Integer32,
sleEthernetPortCpuStatisticsLimitBroadcast
Integer32,
sleEthernetPortFloodBlockBroadcastState
INTEGER,
sleEthernetPortFloodBlockDlfState
INTEGER
}
sleEthernetPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port index."
::= { sleEthernetPortEntry 1 }
sleEthernetPortPhyIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical index of entity mib."
::= { sleEthernetPortEntry 2 }
sleEthernetPortType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
electrical(1),
optical(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of port.
It is not planed to made a automatic switchover between optical and electrical interfaces."
::= { sleEthernetPortEntry 3 }
sleEthernetPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2),
notAvailable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The admin status of port."
::= { sleEthernetPortEntry 4 }
sleEthernetPortOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2),
notAvailable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The oper status of port"
::= { sleEthernetPortEntry 5 }
sleEthernetPortTransmissionRate OBJECT-TYPE
SYNTAX Integer32 (10 | 100 | 1000 | 2500 | 10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The speed of port. Unit is Mbit/s.
This configurations are only useful for electrical interfaces.
Optical - interfaces will always support 1000 MBIT/s"
::= { sleEthernetPortEntry 6 }
sleEthernetPortDuplexMode OBJECT-TYPE
SYNTAX INTEGER
{
full(1),
half(2),
notAvailable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The duplex status of port."
::= { sleEthernetPortEntry 7 }
sleEthernetPortFlowControl OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
enabledSymetrical(2),
enabledAsymetrical(3),
enabledBoth(4),
notAvailable(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flow-control mode of port."
::= { sleEthernetPortEntry 8 }
sleEthernetPortNegotiationMode OBJECT-TYPE
SYNTAX INTEGER
{
auto(1),
force(2),
notAvailable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Auto Negotiation mode of port. "
::= { sleEthernetPortEntry 9 }
sleEthernetPortJumboFrameSize OBJECT-TYPE
SYNTAX Integer32 (0 | 1518..12288)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The jumbo frame's size of port.
If the value is zero, it means that it is not set up."
::= { sleEthernetPortEntry 10 }
sleEthernetPortSfpTransceiver OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
electrical(1),
electricalCoaxial(2),
opticalLongHaul(3),
opticalShortHaul(4),
optical10G(5),
opticalGpon(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortEntry 11 }
sleEthernetPortSfpVendorName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortEntry 12 }
sleEthernetPortSfpVendorPartNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortEntry 13 }
sleEthernetPortSfpVendorRevision OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortEntry 14 }
sleEthernetPortSfpVendorSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortEntry 15 }
sleEthernetPortSfpDateCode OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortEntry 16 }
sleEthernetPortPhysicalRemoteChassis OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortEntry 17 }
sleEthernetPortPhysicalRemoteSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortEntry 18 }
sleEthernetPortPhysicalRemotePort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortEntry 19 }
sleEthernetPortPhysicalLinkDiscoveryMode OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
manual(2),
automatic(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortEntry 20 }
sleEthernetPortSfpTransceiverType OBJECT-TYPE
SYNTAX INTEGER
{
sfp(1),
gbit(2),
xfp(3),
unknown(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of SFP transceiver."
::= { sleEthernetPortEntry 21 }
sleEthernetPortSfpTransceiverDetailType OBJECT-TYPE
SYNTAX INTEGER
{
fiber1000Sx(1),
fiber1000Lx(2),
fiber1000Cx(3),
fiber1000T(4),
fiber100lLxLx10(5),
fiber100Fx(6),
fiberBx10(7),
fiberPx(8),
fiberOc3MmSr(9),
fiberOc3SmIr(10),
fiberOc3SmLr(11),
fiber1000Zx(12),
unknown(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The detailed-type of SFP transceiver."
::= { sleEthernetPortEntry 22 }
sleEthernetPortSlotIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot index."
::= { sleEthernetPortEntry 23 }
sleEthernetPortSlotPortIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot's port index."
::= { sleEthernetPortEntry 24 }
sleEthernetPortAdminTransmissionRate OBJECT-TYPE
SYNTAX Integer32 (10 | 100 | 1000 | 10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The speed of port. Unit is Mbit/s.
This configurations are only useful for electrical interfaces.
Optical - interfaces will always support 1000 MBIT/s"
::= { sleEthernetPortEntry 25 }
sleEthernetPortAdminDuplexMode OBJECT-TYPE
SYNTAX INTEGER
{
full(1),
half(2),
notAvailable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The duplex status of port."
::= { sleEthernetPortEntry 26 }
sleEthernetPortAdminFlowControl OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
enableSend(2),
enableReceive(3),
enabledBoth(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flow-control mode of port."
::= { sleEthernetPortEntry 27 }
sleEthernetPortAdminNegotiationMode OBJECT-TYPE
SYNTAX INTEGER
{
auto(1),
force(2),
notAvailable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Auto Negotiation mode of port. "
::= { sleEthernetPortEntry 28 }
sleEthernetPortAdminReason OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
user(1),
xllcf(2),
all(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The admin down reason of the interface.
user : by user-configuration
xllcf : by xllcf protocol
all : both user and xllcf
"
::= { sleEthernetPortEntry 29 }
sleEthernetPortLinkCheckTimer OBJECT-TYPE
SYNTAX Integer32 (20..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Link check internval of the interface "
::= { sleEthernetPortEntry 30 }
sleEthernetPortLinkDebounceTime OBJECT-TYPE
SYNTAX Integer32 (0 | 10..5000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link debounce time of the interface"
::= { sleEthernetPortEntry 31 }
sleEthernetPortCpuStatisticsLimitUnicast OBJECT-TYPE
SYNTAX Integer32 (0 | 10..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CPU statistics-limit Unicast Count
( the standard unit : 1000, 10 = 1000 )
"
::= { sleEthernetPortEntry 32 }
sleEthernetPortCpuStatisticsLimitMulticast OBJECT-TYPE
SYNTAX Integer32 (0 | 10..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"et CPU statistics-limit Multicast Count
( the standard unit : 1000, 10 = 1000 )
"
::= { sleEthernetPortEntry 33 }
sleEthernetPortCpuStatisticsLimitBroadcast OBJECT-TYPE
SYNTAX Integer32 (0 | 10..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Set CPU statistics-limit Broadcast Count
( the standard unit : 1000, 10 = 1000 )
"
::= { sleEthernetPortEntry 34 }
sleEthernetPortFloodBlockBroadcastState OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Flood Block Broadcast State of the interface"
::= { sleEthernetPortEntry 35 }
sleEthernetPortFloodBlockDlfState OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Flood Block DLF State of the interface"
::= { sleEthernetPortEntry 36 }
sleEthernetPortControl OBJECT IDENTIFIER ::= { sleEthernetPort 2 }
sleEthernetPortControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setEthernetPortProfile(1),
setEthernetPortLinkProfile(2),
setEhternetPortCpuStatisticsLimitProfile(3),
setEthernetPortFloodBlockStateProfile(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 1 }
sleEthernetPortControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 2 }
sleEthernetPortControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 3 }
sleEthernetPortControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 4 }
sleEthernetPortControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 5 }
sleEthernetPortControlIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 6 }
sleEthernetPortControlType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
electrical(1),
optical(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 7 }
sleEthernetPortControlAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2),
notAvailable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 8 }
sleEthernetPortControlTransmissionRate OBJECT-TYPE
SYNTAX Integer32 (10 | 100 | 1000 | 2500 | 10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description.The speed of port. Unit is Mbit/s.
This configurations are only useful for electrical interfaces.
Optical - interfaces will always support 1000 MBIT/s"
::= { sleEthernetPortControl 9 }
sleEthernetPortControlDuplexMode OBJECT-TYPE
SYNTAX INTEGER
{
full(1),
half(2),
notAvailable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 10 }
sleEthernetPortControlFlowControl OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
enabledSymetrical(2),
enabledAsymetrical(3),
enabledBoth(4),
notAvailable(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 11 }
sleEthernetPortControlNegotiationMode OBJECT-TYPE
SYNTAX INTEGER
{
auto(1),
force(2),
notAvailable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 12 }
sleEthernetPortControlJumboFrameSize OBJECT-TYPE
SYNTAX Integer32 (0 | 1518..12288)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description. If the value is zero, it means erasing the set-up value.
"
::= { sleEthernetPortControl 13 }
sleEthernetPortControlPhysicalRemoteChassis OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 14 }
sleEthernetPortControlPhysicalRemoteSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 15 }
sleEthernetPortControlPhysicalRemotePort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 16 }
sleEthernetPortControlPhysicalLinkDiscoveryMode OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
manual(2),
automatic(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortControl 17 }
sleEthernetPortControlLinkCheckTimer OBJECT-TYPE
SYNTAX Integer32 (20..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Link check internval of the interface "
::= { sleEthernetPortControl 18 }
sleEthernetPortControlLinkDebounceTime OBJECT-TYPE
SYNTAX Integer32 (0 | 10..5000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The link debounce time of the interface"
::= { sleEthernetPortControl 19 }
sleEthernetPortControlCpuStatisticsLimitUnicast OBJECT-TYPE
SYNTAX Integer32 (0 | 10..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The CPU statistics-limit Unicast Count
( the standard unit : 1000, 10 = 1000 )
"
::= { sleEthernetPortControl 20 }
sleEthernetPortControlCpuStatisticsLimitMulticast OBJECT-TYPE
SYNTAX Integer32 (0 | 10..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"et CPU statistics-limit Multicast Count
( the standard unit : 1000, 10 = 1000 )
"
::= { sleEthernetPortControl 21 }
sleEthernetPortControlCpuStatisticsLimitBroadcast OBJECT-TYPE
SYNTAX Integer32 (0 | 10..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set CPU statistics-limit Broadcast Count
( the standard unit : 1000, 10 = 1000 )
"
::= { sleEthernetPortControl 22 }
sleEthernetPortControlFloodBlockBroadcastState OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Flood Block Broadcast State of the interface"
::= { sleEthernetPortControl 23 }
sleEthernetPortControlFloodBlockDlfState OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Flood Block DLF State of the interface"
::= { sleEthernetPortControl 24 }
sleEthernetPortNotification OBJECT IDENTIFIER ::= { sleEthernetPort 3 }
sleEthernetPortChanged NOTIFICATION-TYPE
OBJECTS { sleEthernetPortType, sleEthernetPortAdminStatus, sleEthernetPortTransmissionRate, sleEthernetPortDuplexMode, sleEthernetPortFlowControl,
sleEthernetPortNegotiationMode, sleEthernetPortJumboFrameSize, sleEthernetPortSfpVendorName, sleEthernetPortSfpVendorPartNumber, sleEthernetPortSfpVendorRevision,
sleEthernetPortSfpVendorSerialNumber, sleEthernetPortSfpDateCode, sleEthernetPortPhysicalRemoteChassis, sleEthernetPortPhysicalRemoteSlot, sleEthernetPortPhysicalRemotePort,
sleEthernetPortPhysicalLinkDiscoveryMode, sleEthernetPortControlRequest, sleEthernetPortControlTimeStamp, sleEthernetPortControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPortNotification 1 }
sleEthernetPortLinkChanged NOTIFICATION-TYPE
OBJECTS { sleEthernetPortControlRequest, sleEthernetPortControlTimeStamp, sleEthernetPortControlReqResult, sleEthernetPortControlIndex, sleEthernetPortControlLinkCheckTimer,
sleEthernetPortControlLinkDebounceTime }
STATUS current
DESCRIPTION
"setEthernetPortLinkProfile"
::= { sleEthernetPortNotification 2 }
sleEthernetPortCpuStatisticsLimitChanged NOTIFICATION-TYPE
OBJECTS { sleEthernetPortControlRequest, sleEthernetPortControlTimeStamp, sleEthernetPortControlReqResult, sleEthernetPortControlIndex, sleEthernetPortControlCpuStatisticsLimitUnicast,
sleEthernetPortControlCpuStatisticsLimitMulticast, sleEthernetPortControlCpuStatisticsLimitBroadcast }
STATUS current
DESCRIPTION
"setEhternetPortCpuStatisticsLimitProfile"
::= { sleEthernetPortNotification 3 }
sleEthernetPortFloodBlockStateChanged NOTIFICATION-TYPE
OBJECTS { sleEthernetPortControlRequest, sleEthernetPortControlTimeStamp, sleEthernetPortControlReqResult, sleEthernetPortControlIndex, sleEthernetPortControlFloodBlockBroadcastState,
sleEthernetPortControlFloodBlockDlfState }
STATUS current
DESCRIPTION
"setEthernetPortFloodBlockStateProfile"
::= { sleEthernetPortNotification 4 }
sleEthernetPortDMITable OBJECT-TYPE
SYNTAX SEQUENCE OF SleEthernetPortDMIEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPort 4 }
sleEthernetPortDMIEntry OBJECT-TYPE
SYNTAX SleEthernetPortDMIEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleEthernetPortDMIIndex }
::= { sleEthernetPortDMITable 1 }
SleEthernetPortDMIEntry ::=
SEQUENCE {
sleEthernetPortDMIIndex
INTEGER,
sleEthernetPortDMITemper
OCTET STRING,
sleEthernetPortDMIVoltage
OCTET STRING,
sleEthernetPortDMITxBias
OCTET STRING,
sleEthernetPortDMITxPower
OCTET STRING,
sleEthernetPortDMIRxPower
OCTET STRING
}
sleEthernetPortDMIIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port Index."
::= { sleEthernetPortDMIEntry 1 }
sleEthernetPortDMITemper OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured module temperature."
::= { sleEthernetPortDMIEntry 2 }
sleEthernetPortDMIVoltage OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured supply voltage in transceiver."
::= { sleEthernetPortDMIEntry 3 }
sleEthernetPortDMITxBias OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured TX Bias Current."
::= { sleEthernetPortDMIEntry 4 }
sleEthernetPortDMITxPower OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured TX output power."
::= { sleEthernetPortDMIEntry 5 }
sleEthernetPortDMIRxPower OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured RX input power."
::= { sleEthernetPortDMIEntry 6 }
sleEthernetSFPTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleEthernetSFPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPort 5 }
sleEthernetSFPEntry OBJECT-TYPE
SYNTAX SleEthernetSFPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleEthernetSfpIndex }
::= { sleEthernetSFPTable 1 }
SleEthernetSFPEntry ::=
SEQUENCE {
sleEthernetSfpIndex
Integer32,
sleEthernetSfpTransceiver
INTEGER,
sleEthernetSfpVendorName
OCTET STRING,
sleEthernetSfpVendorPartNumber
OCTET STRING,
sleEthernetSfpVendorRevision
OCTET STRING,
sleEthernetSfpVendorSerialNumber
OCTET STRING,
sleEthernetSfpDateCode
OCTET STRING,
sleEthernetSfpTransceiverType
INTEGER,
sleEthernetSfpTransceiverDetailType
INTEGER,
sleEthernetSfpTransceiverCodes
OCTET STRING,
sleEthernetSfpSpeed
OCTET STRING,
sleEthernetSfpLength
Integer32,
sleEthernetSfpWaveLength
Integer32,
sleEthernetSfpMultimodeLengthOm1
Integer32,
sleEthernetSfpMultimodeLengthOm2
Integer32,
sleEthernetSfpMultimodeLengthOm3
Integer32,
sleEthernetSfpTransceiverDetailTypeStr
OCTET STRING,
sleEthernetSfpTransceiverLengthStr
OCTET STRING,
sleEthernetSfpWaveLengthStr
OCTET STRING,
sleEthernetSfpConnectorType
OCTET STRING,
sleEthernetSfpDdmState
INTEGER,
sleEthernetSfpNegoState
INTEGER
}
sleEthernetSfpIndex OBJECT-TYPE
SYNTAX Integer32 (1..65556)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFP index."
::= { sleEthernetSFPEntry 1 }
sleEthernetSfpTransceiver OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
electrical(1),
electricalCoaxial(2),
opticalLongHaul(3),
opticalShortHaul(4),
optical10G(5),
opticalGpon(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of SFP"
::= { sleEthernetSFPEntry 2 }
sleEthernetSfpVendorName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor name of SFP"
::= { sleEthernetSFPEntry 3 }
sleEthernetSfpVendorPartNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part number of SFP"
::= { sleEthernetSFPEntry 4 }
sleEthernetSfpVendorRevision OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The revision of SFP"
::= { sleEthernetSFPEntry 5 }
sleEthernetSfpVendorSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of SFP"
::= { sleEthernetSFPEntry 6 }
sleEthernetSfpDateCode OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The manufacturing date of SFP"
::= { sleEthernetSFPEntry 7 }
sleEthernetSfpTransceiverType OBJECT-TYPE
SYNTAX INTEGER
{
sfp(1),
gbic(2),
xfp(3),
unknown(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of SFP transceiver."
::= { sleEthernetSFPEntry 8 }
sleEthernetSfpTransceiverDetailType OBJECT-TYPE
SYNTAX INTEGER
{
fiber1000Sx(1),
fiber1000Lx(2),
fiber1000Cx(3),
fiber1000T(4),
fiber100lLxLx10(5),
fiber100Fx(6),
fiberBx10(7),
fiberPx(8),
fiberOc3MmSr(9),
fiberOc3SmIr(10),
fiberOc3SmLr(11),
fiber1000Zx(12),
base10GSR(64),
base10GLR(65),
base10GER(66),
base10GLRM(67),
base10GSW(68),
base10GLW(69),
base10GEW(70),
base10GEWorZW(71),
unknown(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The detailed-type of SFP transceiver."
::= { sleEthernetSFPEntry 9 }
sleEthernetSfpTransceiverCodes OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transceiver codes.
In case of SFP, reference SFP-8472 Rev 11.0
- Table 3.5: Transceiver codes (Address A0h)
- Table 3.5a: SONET Compliance Specifiers (A0h)
In case of XFP, reference XFP Specification Revision 4.5 (August 31,2005)
- Table 40 Transceiver codes
"
::= { sleEthernetSFPEntry 10 }
sleEthernetSfpSpeed OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The speed of SFP"
::= { sleEthernetSFPEntry 11 }
sleEthernetSfpLength OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The length of SFP"
::= { sleEthernetSFPEntry 12 }
sleEthernetSfpWaveLength OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wavelength of SFP"
::= { sleEthernetSFPEntry 13 }
sleEthernetSfpMultimodeLengthOm1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Flame rating is 62.5um(OM1). This is used only for 10G SFP module with multi-mode.
ref) 50/125 Multimode Fiber Optic
50/125 is one of the most commonly used multimode optical fiber, the other commonly used is 62.5/125 types.
There is a special kind 50/125 multimode fibers, which is called OM3 50/125. People usually refer 62.5/125 as the OM1 MMF,
common type 50/125 MMF as OM2, OM3 is also 50/125, but it is different from OM2 because it support 10Gig data transmission.
The OM3 50/125 fiber optic cable is also called laser optimized fiber cable.
Both OM1 and OM2 multimode cables use the orange color jacket (standard practice for commonly used indoor multimode),
OM3 use a special color, which is called Aqua."
::= { sleEthernetSFPEntry 14 }
sleEthernetSfpMultimodeLengthOm2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Flame rating is 50um(OM2). This is used only for 10G SFP module with multi-mode.
ref) 50/125 Multimode Fiber Optic
50/125 is one of the most commonly used multimode optical fiber, the other commonly used is 62.5/125 types.
There is a special kind 50/125 multimode fibers, which is called OM3 50/125. People usually refer 62.5/125 as the OM1 MMF,
common type 50/125 MMF as OM2, OM3 is also 50/125, but it is different from OM2 because it support 10Gig data transmission.
The OM3 50/125 fiber optic cable is also called laser optimized fiber cable.
Both OM1 and OM2 multimode cables use the orange color jacket (standard practice for commonly used indoor multimode),
OM3 use a special color, which is called Aqua."
::= { sleEthernetSFPEntry 15 }
sleEthernetSfpMultimodeLengthOm3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Flame rating is 50um(OM3). This is used only for 10G SFP module with multi-mode.
ref) 50/125 Multimode Fiber Optic
50/125 is one of the most commonly used multimode optical fiber, the other commonly used is 62.5/125 types.
There is a special kind 50/125 multimode fibers, which is called OM3 50/125. People usually refer 62.5/125 as the OM1 MMF,
common type 50/125 MMF as OM2, OM3 is also 50/125, but it is different from OM2 because it support 10Gig data transmission.
The OM3 50/125 fiber optic cable is also called laser optimized fiber cable.
Both OM1 and OM2 multimode cables use the orange color jacket (standard practice for commonly used indoor multimode),
OM3 use a special color, which is called Aqua."
::= { sleEthernetSFPEntry 16 }
sleEthernetSfpTransceiverDetailTypeStr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPEntry 17 }
sleEthernetSfpTransceiverLengthStr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPEntry 18 }
sleEthernetSfpWaveLengthStr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPEntry 19 }
sleEthernetSfpConnectorType OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPEntry 20 }
sleEthernetSfpDdmState OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DDM state"
::= { sleEthernetSFPEntry 21 }
sleEthernetSfpNegoState OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Nego state"
::= { sleEthernetSFPEntry 22 }
sleEthernetSFPControl OBJECT IDENTIFIER ::= { sleEthernetPort 6 }
sleEthernetSFPControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setSFPRemoteReset(1),
setSFPDdmState(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPControl 1 }
sleEthernetSFPControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPControl 2 }
sleEthernetSFPControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPControl 3 }
sleEthernetSFPControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPControl 4 }
sleEthernetSFPControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPControl 5 }
sleEthernetSFPControlIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPControl 6 }
sleEthernetSfpControlDdmState OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPControl 7 }
sleEthernetSFPNotification OBJECT IDENTIFIER ::= { sleEthernetPort 7 }
sleEthernetSFPRemoteReset NOTIFICATION-TYPE
OBJECTS { sleEthernetSFPControlRequest, sleEthernetSFPControlTimeStamp, sleEthernetSFPControlReqResult, sleEthernetSFPControlIndex }
STATUS current
DESCRIPTION
"setSFPRemoteReset"
::= { sleEthernetSFPNotification 1 }
sleEthernetSFPDdmState NOTIFICATION-TYPE
OBJECTS { sleEthernetSFPControlRequest, sleEthernetSFPControlTimeStamp, sleEthernetSFPControlReqResult, sleEthernetSFPControlIndex, sleEthernetSfpControlDdmState
}
STATUS current
DESCRIPTION
"setSFPDdmState"
::= { sleEthernetSFPNotification 2 }
sleEthernetSFPThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleEthernetSFPThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetPort 8 }
sleEthernetSFPThresholdEntry OBJECT-TYPE
SYNTAX SleEthernetSFPThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleEthernetSFPThresholdIfIndex, sleEthernetSFPThresholdType }
::= { sleEthernetSFPThresholdTable 1 }
SleEthernetSFPThresholdEntry ::=
SEQUENCE {
sleEthernetSFPThresholdIfIndex
Integer32,
sleEthernetSFPThresholdType
INTEGER,
sleEthernetSFPThresholdSfpLow
OCTET STRING,
sleEthernetSFPThresholdSfpHigh
OCTET STRING,
sleEthernetSFPThresholdSystemLow
OCTET STRING,
sleEthernetSFPThresholdSystemHigh
OCTET STRING
}
sleEthernetSFPThresholdIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the interface"
::= { sleEthernetSFPThresholdEntry 1 }
sleEthernetSFPThresholdType OBJECT-TYPE
SYNTAX INTEGER
{
temperWarning(1),
temperAlarm(2),
voltageWarning(3),
voltageAlarm(4),
txbiasWarning(5),
txbiasAlarm(6),
txpowerWarning(7),
txpowerAlarm(8),
rxpowerWarning(9),
rxpowerAlarm(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Type of Threshold"
::= { sleEthernetSFPThresholdEntry 2 }
sleEthernetSFPThresholdSfpLow OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Threshold Low Value of Sfp"
::= { sleEthernetSFPThresholdEntry 3 }
sleEthernetSFPThresholdSfpHigh OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Threshold High Value of Sfp"
::= { sleEthernetSFPThresholdEntry 4 }
sleEthernetSFPThresholdSystemLow OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Threshold Low Value of System"
::= { sleEthernetSFPThresholdEntry 5 }
sleEthernetSFPThresholdSystemHigh OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Threshold High Value of System"
::= { sleEthernetSFPThresholdEntry 6 }
sleEthernetSFPThresholdControl OBJECT IDENTIFIER ::= { sleEthernetPort 9 }
sleEthernetSFPThresholdControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setSfpThresholdModule(1),
setSystemThresholdModule(2),
delThresholdModule(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPThresholdControl 1 }
sleEthernetSFPThresholdControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPThresholdControl 2 }
sleEthernetSFPThresholdControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPThresholdControl 3 }
sleEthernetSFPThresholdControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPThresholdControl 4 }
sleEthernetSFPThresholdControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEthernetSFPThresholdControl 5 }
sleEthernetSFPThresholdControlIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The index of the interface"
::= { sleEthernetSFPThresholdControl 6 }
sleEthernetSFPThresholdControlType OBJECT-TYPE
SYNTAX INTEGER
{
temperWarning(1),
temperAlarm(2),
voltageWarning(3),
voltageAlarm(4),
txbiasWarning(5),
txbiasAlarm(6),
txpowerWarning(7),
txpowerAlarm(8),
rxpowerWarning(9),
rxpowerAlarm(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Type of Threshold"
::= { sleEthernetSFPThresholdControl 7 }
sleEthernetSFPThresholdControlSfpLow OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Threshold Low Value of Sfp"
::= { sleEthernetSFPThresholdControl 8 }
sleEthernetSFPThresholdControlSfpHigh OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Threshold High Value of Sfp"
::= { sleEthernetSFPThresholdControl 9 }
sleEthernetSFPThresholdControlSystemLow OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Threshold Low Value of System"
::= { sleEthernetSFPThresholdControl 10 }
sleEthernetSFPThresholdControlSystemHigh OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Threshold High Value of System"
::= { sleEthernetSFPThresholdControl 11 }
sleEthernetSFPThresholdNotification OBJECT IDENTIFIER ::= { sleEthernetPort 10 }
sleEthernetSFPThresholdSfpChanged NOTIFICATION-TYPE
OBJECTS { sleEthernetSFPThresholdControlRequest, sleEthernetSFPThresholdControlTimeStamp, sleEthernetSFPThresholdControlReqResult, sleEthernetSFPThresholdControlIfIndex, sleEthernetSFPThresholdControlType,
sleEthernetSFPThresholdControlSfpLow, sleEthernetSFPThresholdControlSfpHigh }
STATUS current
DESCRIPTION
"setSfpThresholdModule "
::= { sleEthernetSFPThresholdNotification 1 }
sleEthernetSFPThresholdSystemChanged NOTIFICATION-TYPE
OBJECTS { sleEthernetSFPThresholdControlRequest, sleEthernetSFPThresholdControlTimeStamp, sleEthernetSFPThresholdControlReqResult, sleEthernetSFPThresholdControlIfIndex, sleEthernetSFPThresholdControlType,
sleEthernetSFPThresholdControlSystemLow, sleEthernetSFPThresholdControlSystemHigh }
STATUS current
DESCRIPTION
"setSystemThresholdModule "
::= { sleEthernetSFPThresholdNotification 2 }
sleEthernetSFPThresholdDestroyed NOTIFICATION-TYPE
OBJECTS { sleEthernetSFPThresholdControlRequest, sleEthernetSFPThresholdControlTimeStamp, sleEthernetSFPThresholdControlReqResult, sleEthernetSFPThresholdControlIfIndex, sleEthernetSFPThresholdControlType
}
STATUS current
DESCRIPTION
"delThresholdModule "
::= { sleEthernetSFPThresholdNotification 3 }
slePower OBJECT IDENTIFIER ::= { sleDevice 3 }
slePowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlePowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { slePower 1 }
slePowerEntry OBJECT-TYPE
SYNTAX SlePowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { slePowerIndex }
::= { slePowerTable 1 }
SlePowerEntry ::=
SEQUENCE {
slePowerIndex
INTEGER,
slePowerPhyIndex
Integer32,
slePowerState
INTEGER,
slePowerType
INTEGER,
slePowerPSUType
INTEGER
}
slePowerIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each module. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization."
::= { slePowerEntry 1 }
slePowerPhyIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"entPhysicalIndex of Power Modules (0: Internal, -1: uninstalled)"
::= { slePowerEntry 2 }
slePowerState OBJECT-TYPE
SYNTAX INTEGER
{
failure(0),
ok(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power status information."
::= { slePowerEntry 3 }
slePowerType OBJECT-TYPE
SYNTAX INTEGER
{
ac(1),
dc(2),
unknown(3),
psu(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power type information."
::= { slePowerEntry 4 }
slePowerPSUType OBJECT-TYPE
SYNTAX INTEGER
{
psuA(1),
psuS(2),
unknown(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Power Supply Unit.(DC)"
::= { slePowerEntry 5 }
sleFanModule OBJECT IDENTIFIER ::= { sleDevice 4 }
sleFanModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleFanModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleFanModule 1 }
sleFanModuleEntry OBJECT-TYPE
SYNTAX SleFanModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleFanModuleIndex }
::= { sleFanModuleTable 1 }
SleFanModuleEntry ::=
SEQUENCE {
sleFanModuleIndex
INTEGER,
sleFanModulePhyIndex
Integer32,
sleFanModuleUnitNum
Integer32,
sleFanModuleAdminState
INTEGER,
sleFanModuleSpeedThreshold
Integer32
}
sleFanModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each module. It is recommended that values are assigned contiguously starting from 1."
::= { sleFanModuleEntry 1 }
sleFanModulePhyIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"entPhysicalIndex of FAN Modules. (0: Internal, -1: uninstalled)"
::= { sleFanModuleEntry 2 }
sleFanModuleUnitNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of unit in FAN module"
::= { sleFanModuleEntry 3 }
sleFanModuleAdminState OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1),
auto(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An administrative state of FAN module"
::= { sleFanModuleEntry 4 }
sleFanModuleSpeedThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fan-speed threshold"
::= { sleFanModuleEntry 5 }
sleFanModuleControl OBJECT IDENTIFIER ::= { sleFanModule 2 }
sleFanModuleControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setFanAdminState(1),
setFanSpeedThreshold(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set an administrative state of FAN module"
::= { sleFanModuleControl 1 }
sleFanModuleControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleFanModuleControl 2 }
sleFanModuleControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleFanModuleControl 3 }
sleFanModuleControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleFanModuleControl 4 }
sleFanModuleControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleFanModuleControl 5 }
sleFanModuleControlIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleFanModuleControl 6 }
sleFanModuleControlAdminState OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1),
auto(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An administrative state of FAN module"
::= { sleFanModuleControl 7 }
sleFanModuleControlSpeedThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Fan-speed threshold"
::= { sleFanModuleControl 8 }
sleFanModuleNotification OBJECT IDENTIFIER ::= { sleFanModule 3 }
sleFanAdminStateChanged NOTIFICATION-TYPE
OBJECTS { sleFanModuleAdminState, sleFanModuleControlRequest, sleFanModuleControlTimeStamp, sleFanModuleControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleFanModuleNotification 1 }
sleFanSpeedThresholdChanged NOTIFICATION-TYPE
OBJECTS { sleFanModuleControlRequest, sleFanModuleControlTimeStamp, sleFanModuleControlReqResult, sleFanModuleControlIndex, sleFanModuleControlSpeedThreshold
}
STATUS current
DESCRIPTION
"Description."
::= { sleFanModuleNotification 2 }
sleFanUnit OBJECT IDENTIFIER ::= { sleDevice 5 }
sleFanUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleFanUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleFanUnit 1 }
sleFanUnitEntry OBJECT-TYPE
SYNTAX SleFanUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleFanModuleIndex, sleFanUnitIndex }
::= { sleFanUnitTable 1 }
SleFanUnitEntry ::=
SEQUENCE {
sleFanUnitIndex
INTEGER,
sleFanUnitOperState
INTEGER,
sleFanUnitSpeed
Integer32
}
sleFanUnitIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number in FAN module"
::= { sleFanUnitEntry 1 }
sleFanUnitOperState OBJECT-TYPE
SYNTAX INTEGER
{
failure(0),
ok(1),
stop(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An operational state of FAN unit"
::= { sleFanUnitEntry 2 }
sleFanUnitSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Speed of FAN unit"
::= { sleFanUnitEntry 3 }
sleTemperature OBJECT IDENTIFIER ::= { sleDevice 6 }
sleTemperatureTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleTemperatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleTemperature 1 }
sleTemperatureEntry OBJECT-TYPE
SYNTAX SleTemperatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleTemperatureIndex }
::= { sleTemperatureTable 1 }
SleTemperatureEntry ::=
SEQUENCE {
sleTemperatureIndex
INTEGER,
sleTemperatureState
INTEGER,
sleTemperatureValue
Integer32,
sleTemperatureHighThreshold
Integer32,
sleTemperatureLowThreshold
Integer32,
sleTemperatureWarnHighThreshold
Integer32,
sleTemperatureWarnLowThreshold
Integer32,
sleTemperatureWarnDuration
Integer32,
sleTemperatureAlarmHighThreshold
Integer32,
sleTemperatureAlarmLowThreshold
Integer32,
sleTemperatureAlarmDuration
Integer32
}
sleTemperatureIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each module. It is recommended that values are assigned contiguously starting from 1."
::= { sleTemperatureEntry 1 }
sleTemperatureState OBJECT-TYPE
SYNTAX INTEGER
{
failure(0),
ok(1),
others(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature status information"
::= { sleTemperatureEntry 2 }
sleTemperatureValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of temperature sensor. (unit: C)"
::= { sleTemperatureEntry 3 }
sleTemperatureHighThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The High threshold of temperature."
::= { sleTemperatureEntry 4 }
sleTemperatureLowThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Low threshold of temperature."
::= { sleTemperatureEntry 5 }
sleTemperatureWarnHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The High threshold of temperature."
::= { sleTemperatureEntry 6 }
sleTemperatureWarnLowThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Low threshold of temperature."
::= { sleTemperatureEntry 7 }
sleTemperatureWarnDuration OBJECT-TYPE
SYNTAX Integer32 (0..300)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duration-time units by the 5 sec.
0: Clear threshold."
::= { sleTemperatureEntry 8 }
sleTemperatureAlarmHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The High threshold of temperature."
::= { sleTemperatureEntry 9 }
sleTemperatureAlarmLowThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Low threshold of temperature."
::= { sleTemperatureEntry 10 }
sleTemperatureAlarmDuration OBJECT-TYPE
SYNTAX Integer32 (0..300)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duration-time units by the 5 sec.
0: Clear threshold."
::= { sleTemperatureEntry 11 }
sleTemperatureControl OBJECT IDENTIFIER ::= { sleTemperature 2 }
sleTemperatureControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setTempThreshold(1),
setTempAlarmThreshold(2),
setTempWarnThreshold(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set an administrative state of FAN module"
::= { sleTemperatureControl 1 }
sleTemperatureControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleTemperatureControl 2 }
sleTemperatureControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleTemperatureControl 3 }
sleTemperatureControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleTemperatureControl 4 }
sleTemperatureControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleTemperatureControl 5 }
sleTemperatureControlIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Temperature index"
::= { sleTemperatureControl 6 }
sleTemperatureControlHighThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The High threshold of temperature."
::= { sleTemperatureControl 7 }
sleTemperatureControlLowThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Low threshold of temperature."
::= { sleTemperatureControl 8 }
sleTemperatureControlDuration OBJECT-TYPE
SYNTAX Integer32 (0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Duration-time units by the 5 sec.
0: Clear threshold."
::= { sleTemperatureControl 9 }
sleTemperatureNotification OBJECT IDENTIFIER ::= { sleTemperature 3 }
sleTemperatureThresholdChanged NOTIFICATION-TYPE
OBJECTS { sleTemperatureControlRequest, sleTemperatureControlTimeStamp, sleTemperatureControlReqResult, sleTemperatureIndex, sleTemperatureWarnHighThreshold,
sleTemperatureWarnLowThreshold, sleTemperatureWarnDuration, sleTemperatureAlarmHighThreshold, sleTemperatureAlarmLowThreshold, sleTemperatureLowThreshold,
sleTemperatureAlarmDuration, sleTemperatureHighThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleTemperatureNotification 1 }
sleBattery OBJECT IDENTIFIER ::= { sleDevice 7 }
sleBatteryTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleBatteryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleBattery 1 }
sleBatteryEntry OBJECT-TYPE
SYNTAX SleBatteryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleBatteryIndex }
::= { sleBatteryTable 1 }
SleBatteryEntry ::=
SEQUENCE {
sleBatteryIndex
INTEGER,
sleOperationPowerType
INTEGER,
sleOperationPowerInfo
OCTET STRING,
slePSUACPowerState
INTEGER,
slePSUTemperture
Integer32,
slePSUTempThreshold
Integer32,
slePSUOutVoltage
OCTET STRING,
slePSUOverTemp
INTEGER,
slePSUFirmwareVer
Integer32,
sleRBUEquipState
INTEGER,
sleRBUModeStaus
OCTET STRING,
sleRBUTemperature1
Integer32,
sleRBUTemperature2
Integer32,
sleRBUTempLowThreshold
Integer32,
sleRBUOutVoltage
OCTET STRING,
sleRBUChargeCurrent
Integer32,
sleRBURemainCapacity
Integer32,
sleRBUOverTemp
INTEGER,
sleBatteryLow
INTEGER,
sleRBUTempHighThreshold
Integer32,
sleRBUBTStatus
INTEGER,
sleRBUBTThreshold
Integer32,
sleRBURechargeVoltage
Integer32,
sleBatteryCellStatus
INTEGER,
sleBPSUACHardwareVer
Integer32
}
sleBatteryIndex OBJECT-TYPE
SYNTAX INTEGER (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of battery charger."
::= { sleBatteryEntry 1 }
sleOperationPowerType OBJECT-TYPE
SYNTAX INTEGER
{
ac(0),
rbu(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power Type."
::= { sleBatteryEntry 2 }
sleOperationPowerInfo OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operation Power Info."
::= { sleBatteryEntry 3 }
slePSUACPowerState OBJECT-TYPE
SYNTAX INTEGER
{
ok(0),
fault(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power State."
::= { sleBatteryEntry 4 }
slePSUTemperture OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperture."
::= { sleBatteryEntry 5 }
slePSUTempThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperture Threshold."
::= { sleBatteryEntry 6 }
slePSUOutVoltage OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Voltage."
::= { sleBatteryEntry 7 }
slePSUOverTemp OBJECT-TYPE
SYNTAX INTEGER
{
normal(0),
over(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryEntry 8 }
slePSUFirmwareVer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The firmware version of battery charger for communication to system."
::= { sleBatteryEntry 9 }
sleRBUEquipState OBJECT-TYPE
SYNTAX INTEGER
{
equipped(0),
empty(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Equipment State."
::= { sleBatteryEntry 10 }
sleRBUModeStaus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryEntry 11 }
sleRBUTemperature1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryEntry 12 }
sleRBUTemperature2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"."
::= { sleBatteryEntry 13 }
sleRBUTempLowThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RBU Low Temperature Threshold."
::= { sleBatteryEntry 14 }
sleRBUOutVoltage OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RBU Out Voltage."
::= { sleBatteryEntry 15 }
sleRBUChargeCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Charge."
::= { sleBatteryEntry 16 }
sleRBURemainCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remain Capacity."
::= { sleBatteryEntry 17 }
sleRBUOverTemp OBJECT-TYPE
SYNTAX INTEGER
{
normal(0),
over(1),
under(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of Temperature over."
::= { sleBatteryEntry 18 }
sleBatteryLow OBJECT-TYPE
SYNTAX INTEGER
{
normal(0),
low(1),
notAvailable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Battery state."
::= { sleBatteryEntry 19 }
sleRBUTempHighThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RBU High Temperature Threshold."
::= { sleBatteryEntry 20 }
sleRBUBTStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryEntry 21 }
sleRBUBTThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryEntry 22 }
sleRBURechargeVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryEntry 23 }
sleBatteryCellStatus OBJECT-TYPE
SYNTAX INTEGER
{
ok(1),
failure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryEntry 24 }
sleBPSUACHardwareVer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryEntry 25 }
sleBatteryControl OBJECT IDENTIFIER ::= { sleBattery 2 }
sleBatteryControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setBatteryForceCharge(1),
setBatteryChargingStart(2),
setBatteryForceChargeNonStop(3),
setBatteryBootingTimeStatus(4),
setBatteryBootingTime(5),
setBatteryRechargeVoltage(6),
setPsuAcTemperature(7),
setBatteryTemperature(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryControl 1 }
sleBatteryControlStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryControl 2 }
sleBatteryControlTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryControl 3 }
sleBatteryControlTimeStamp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryControl 4 }
sleBatteryControlReqResult OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryControl 5 }
sleBatteryControlRBUBTStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryControl 6 }
sleBatteryControlRBUBTThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryControl 7 }
sleBatteryControlRBURechargeVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryControl 8 }
sleBatteryControlTemperThresh1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryControl 9 }
sleBatteryControlTemperThresh2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryControl 10 }
sleBatteryNotification OBJECT IDENTIFIER ::= { sleBattery 3 }
sleBatteryForceChargeChanged NOTIFICATION-TYPE
OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryNotification 1 }
sleBatteryChargingStartChanged NOTIFICATION-TYPE
OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryNotification 2 }
sleBatteryForceChargeNonStopChanged NOTIFICATION-TYPE
OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryNotification 3 }
sleBatteryRBUBTStatusChanged NOTIFICATION-TYPE
OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult, sleRBUBTStatus }
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryNotification 4 }
sleBatteryRBUBTThresholdChanged NOTIFICATION-TYPE
OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult, sleRBUBTThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryNotification 5 }
sleBatteryRBURechargeVoltageChanged NOTIFICATION-TYPE
OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult, sleRBURechargeVoltage }
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryNotification 6 }
sleBatteryPsuAcTemperThreshChanged NOTIFICATION-TYPE
OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult, slePSUTempThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryNotification 7 }
sleBatteryRBUTemperThreshChanged NOTIFICATION-TYPE
OBJECTS { sleBatteryControlRequest, sleBatteryControlTimeStamp, sleBatteryControlReqResult, sleRBUTempLowThreshold, sleRBUTempHighThreshold
}
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryNotification 8 }
sleBatteryBackupTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleBatteryBackupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleBattery 4 }
sleBatteryBackupEntry OBJECT-TYPE
SYNTAX SleBatteryBackupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleBatteryBackupFile }
::= { sleBatteryBackupTable 1 }
SleBatteryBackupEntry ::=
SEQUENCE {
sleBatteryBackupFile
OCTET STRING
}
sleBatteryBackupFile OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryBackupEntry 1 }
sleBatteryBackupControl OBJECT IDENTIFIER ::= { sleBattery 5 }
sleBatteryBackupControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setBatteryBackupProfile(1),
setBatteryUpgrade(2),
clearBatteryBackupTable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryBackupControl 1 }
sleBatteryBackupControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryBackupControl 2 }
sleBatteryBackupControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryBackupControl 3 }
sleBatteryBackupControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryBackupControl 4 }
sleBatteryBackupControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryBackupControl 5 }
sleBatteryBackupControlServerIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryBackupControl 6 }
sleBatteryBackupControlUserID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryBackupControl 7 }
sleBatteryBackupControlPassword OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryBackupControl 8 }
sleBatteryBackupControlFlag OBJECT-TYPE
SYNTAX INTEGER
{
download(1),
upload(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryBackupControl 9 }
sleBatteryBackupControlLocalFile OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryBackupControl 10 }
sleBatteryBackupControlRemoteFile OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBatteryBackupControl 11 }
sleBatterBackupNotification OBJECT IDENTIFIER ::= { sleBattery 6 }
sleBatteryBackupProfileChanged NOTIFICATION-TYPE
OBJECTS { sleBatteryBackupControlRequest, sleBatteryBackupControlTimeStamp, sleBatteryBackupControlReqResult, sleBatteryBackupControlServerIP, sleBatteryBackupControlUserID,
sleBatteryBackupControlPassword, sleBatteryBackupControlFlag, sleBatteryBackupControlLocalFile, sleBatteryBackupControlRemoteFile }
STATUS current
DESCRIPTION
"Description."
::= { sleBatterBackupNotification 1 }
sleBatteryBackupUpgraded NOTIFICATION-TYPE
OBJECTS { sleBatteryBackupControlRequest, sleBatteryBackupControlTimeStamp, sleBatteryBackupControlReqResult, sleBatteryBackupControlLocalFile }
STATUS current
DESCRIPTION
"Description."
::= { sleBatterBackupNotification 2 }
sleBatteryBackupTableCleared NOTIFICATION-TYPE
OBJECTS { sleBatteryBackupControlRequest, sleBatteryBackupControlTimeStamp, sleBatteryBackupControlReqResult, sleBatteryBackupControlLocalFile }
STATUS current
DESCRIPTION
"Description."
::= { sleBatterBackupNotification 3 }
sleDoor OBJECT IDENTIFIER ::= { sleDevice 8 }
sleDoorInfo OBJECT IDENTIFIER ::= { sleDoor 1 }
sleDoorStatus OBJECT-TYPE
SYNTAX INTEGER
{
close(0),
open(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleDoorInfo 1 }
sleCpu OBJECT IDENTIFIER ::= { sleDevice 9 }
sleCpuInfo OBJECT IDENTIFIER ::= { sleCpu 1 }
sleCpuProcessor OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCpuInfo 1 }
sleCpuModel OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCpuInfo 2 }
sleCpuRevision OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCpuInfo 3 }
sleCpuBogomips OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCpuInfo 4 }
sleCpuManufacturer OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCpuInfo 5 }
sleCpuClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCpuInfo 6 }
sleCpuBusClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCpuInfo 7 }
sleClockModule OBJECT IDENTIFIER ::= { sleDevice 10 }
sleClockModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleClockModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleClockModule 1 }
sleClockModuleEntry OBJECT-TYPE
SYNTAX SleClockModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleClockModuleIndex }
::= { sleClockModuleTable 1 }
SleClockModuleEntry ::=
SEQUENCE {
sleClockModuleIndex
INTEGER,
sleClockModuleBoardId
INTEGER,
sleClockModuleInstallStatus
INTEGER,
sleClockModuleInitStatus
INTEGER,
sleClockModuleOPMode
INTEGER
}
sleClockModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each module. It is recommended that values are assigned contiguously starting from 1."
::= { sleClockModuleEntry 1 }
sleClockModuleBoardId OBJECT-TYPE
SYNTAX INTEGER
{
sfuA(1),
sfuB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indication of the board identifier."
::= { sleClockModuleEntry 2 }
sleClockModuleInstallStatus OBJECT-TYPE
SYNTAX INTEGER
{
removed(0),
installed(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The install status of clock module."
::= { sleClockModuleEntry 3 }
sleClockModuleInitStatus OBJECT-TYPE
SYNTAX INTEGER
{
failure(0),
ok(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The initialization status of clock module."
::= { sleClockModuleEntry 4 }
sleClockModuleOPMode OBJECT-TYPE
SYNTAX INTEGER
{
freerun(1),
holdover(2),
locked(3),
prelocked2(4),
prelocked(5),
lostphase(6),
unknown(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The CM operating mode"
::= { sleClockModuleEntry 5 }
sleClockInfo OBJECT IDENTIFIER ::= { sleClockModule 2 }
sleClockInfoInSrcType OBJECT-TYPE
SYNTAX INTEGER
{
ntt(1),
ntt2(2),
e1(3),
t1(4),
unknown(255)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The clock input source type."
::= { sleClockInfo 1 }
sleClockInfoInSrcStatus OBJECT-TYPE
SYNTAX INTEGER
{
true(1),
false(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The input source is Valid or Invalid."
::= { sleClockInfo 2 }
sleClockInfoInSrcAISStatus OBJECT-TYPE
SYNTAX INTEGER
{
true(1),
false(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The AIS is detected or not detected."
::= { sleClockInfo 3 }
sleClockInfoInSrcLoSStatus OBJECT-TYPE
SYNTAX INTEGER
{
true(1),
false(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The LoS is detected or not detected"
::= { sleClockInfo 4 }
sleClockInfoInSrcLDSCStatus OBJECT-TYPE
SYNTAX INTEGER
{
true(1),
false(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The Line Driver Short Circuit is detected or not detected"
::= { sleClockInfo 5 }
sleClockInfoInSrcNtrClockType OBJECT-TYPE
SYNTAX BITS
{
bit64Khz(0),
bit8Khz(1),
bit04Khz(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The ntr clock is changed."
::= { sleClockInfo 6 }
sleSlot OBJECT IDENTIFIER ::= { sleDevice 11 }
sleSlotSystemInfo OBJECT IDENTIFIER ::= { sleSlot 1 }
sleSlotSystemInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleSlotSystemInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleSlotSystemInfo 1 }
sleSlotSystemInfoEntry OBJECT-TYPE
SYNTAX SleSlotSystemInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleSlotSystemIndex }
::= { sleSlotSystemInfoTable 1 }
SleSlotSystemInfoEntry ::=
SEQUENCE {
sleSlotSystemIndex
Integer32,
sleSlotSystemUptime
TimeTicks,
sleSlotSystemModelName
OCTET STRING,
sleSlotSystemSerialNumber
OCTET STRING,
sleSlotSystemHWVersion
OCTET STRING,
sleSlotSystemBLVersion
OCTET STRING,
sleSlotSystemSWCompatibility
OCTET STRING,
sleSlotSystemOSVersion
OCTET STRING,
sleSlotSystemMacAddress
OCTET STRING,
sleSlotSystemCPULoadAll
OCTET STRING,
sleSlotSystemCPULoadInterrupt
OCTET STRING,
sleSlotSystemMemoryTotal
Gauge32,
sleSlotSystemMemoryFree
Gauge32,
sleSlotSystemMemoryShared
Gauge32,
sleSlotSystemMemoryBuffers
Gauge32,
sleSlotSystemMemoryCached
Gauge32,
sleSlotSystemMemorySwapTotal
Gauge32,
sleSlotSystemMemorySwapFree
Gauge32,
sleSlotSystemBootReason
INTEGER,
sleSlotSystemBootTime
Gauge32,
sleSlotSystemVoltage
Gauge32,
sleSlotSystemPowerLevelStatus
INTEGER,
sleSlotSystemInfoLEDStatus
BITS,
sleSlotSystemInfoPackageVersion
OCTET STRING,
sleSlotSystemInfoManufacturer
OCTET STRING,
sleSlotSystemInfoManufactureDate
OCTET STRING,
sleSlotSystemCPULoadHighThreshold
Integer32,
sleSlotSystemCPULoadHighThresholdTimer
INTEGER,
sleSlotSystemCPULoadLowThreshold
Integer32,
sleSlotSystemCPULoadLowThresholdTimer
INTEGER,
sleSlotSystemCPULoadCurrent
Integer32,
sleSlotSystemCPUOverallStatus
INTEGER,
sleSlotSystemTemperOverallStatus
INTEGER
}
sleSlotSystemIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system slot index."
::= { sleSlotSystemInfoEntry 1 }
sleSlotSystemUptime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time since the network management portion of the system was last re-initialized."
::= { sleSlotSystemInfoEntry 2 }
sleSlotSystemModelName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The model name."
::= { sleSlotSystemInfoEntry 3 }
sleSlotSystemSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number "
::= { sleSlotSystemInfoEntry 4 }
sleSlotSystemHWVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The H/W version."
::= { sleSlotSystemInfoEntry 5 }
sleSlotSystemBLVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The boot loader<65><72>s S/W version."
::= { sleSlotSystemInfoEntry 6 }
sleSlotSystemSWCompatibility OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system compatibility."
::= { sleSlotSystemInfoEntry 7 }
sleSlotSystemOSVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version information of current os."
::= { sleSlotSystemInfoEntry 8 }
sleSlotSystemMacAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system<65><6D>s MAC address."
::= { sleSlotSystemInfoEntry 9 }
sleSlotSystemCPULoadAll OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CPU all load for 5/60/600 second. (unit: 0.01%)"
::= { sleSlotSystemInfoEntry 10 }
sleSlotSystemCPULoadInterrupt OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CPU interrupt load for 5/60/600 second. (unit: 0.01%)"
::= { sleSlotSystemInfoEntry 11 }
sleSlotSystemMemoryTotal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total memory size (unit: kb)"
::= { sleSlotSystemInfoEntry 12 }
sleSlotSystemMemoryFree OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The freed memory size (unit: kb)"
::= { sleSlotSystemInfoEntry 13 }
sleSlotSystemMemoryShared OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The shared memory size (unit: kb)"
::= { sleSlotSystemInfoEntry 14 }
sleSlotSystemMemoryBuffers OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The buffer size (unit: kb)"
::= { sleSlotSystemInfoEntry 15 }
sleSlotSystemMemoryCached OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cached memory size (unit: kb)"
::= { sleSlotSystemInfoEntry 16 }
sleSlotSystemMemorySwapTotal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total swap memory size (unit: kb)"
::= { sleSlotSystemInfoEntry 17 }
sleSlotSystemMemorySwapFree OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The freed swap memory size (unit: kb)"
::= { sleSlotSystemInfoEntry 18 }
sleSlotSystemBootReason OBJECT-TYPE
SYNTAX INTEGER
{
powerBoot(1),
powerBootByLocal(2),
hwResetBySW(3),
hardWdogByLocal(4),
hwRebootByMate(5),
hwRebootBySwitchover(6),
swReboot(10),
swRebootByLocal(11),
swRebootBySFU(12),
swRebootBySwitchover(13),
swRebootByPanic(14),
watchdog(20),
watchdogByLocal(21),
swWatchdog(30),
swWatchdogByCpuOver(31),
swWatchdogByMemoryLow(32),
error(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system slot boot reason."
::= { sleSlotSystemInfoEntry 19 }
sleSlotSystemBootTime OBJECT-TYPE
SYNTAX Gauge32
UNITS "1 second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system slot boot time.
The time since the Epoch (00:00:00 UTC, January 1, 1970), measured in seconds.
"
::= { sleSlotSystemInfoEntry 20 }
sleSlotSystemVoltage OBJECT-TYPE
SYNTAX Gauge32
UNITS "0.1 v"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system slot voltage."
::= { sleSlotSystemInfoEntry 21 }
sleSlotSystemPowerLevelStatus OBJECT-TYPE
SYNTAX INTEGER
{
good(1),
bad(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCB Power level status."
::= { sleSlotSystemInfoEntry 22 }
sleSlotSystemInfoLEDStatus OBJECT-TYPE
SYNTAX BITS
{
pwr(0),
run(1),
critical(2),
major(3),
minor(4),
error(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The LED status of each slot."
::= { sleSlotSystemInfoEntry 23 }
sleSlotSystemInfoPackageVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The applied package revision."
::= { sleSlotSystemInfoEntry 24 }
sleSlotSystemInfoManufacturer OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ths manufacturer name and country."
::= { sleSlotSystemInfoEntry 25 }
sleSlotSystemInfoManufactureDate OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ths manufacture date."
::= { sleSlotSystemInfoEntry 26 }
sleSlotSystemCPULoadHighThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The high threshold of CPU load (70:default)"
::= { sleSlotSystemInfoEntry 27 }
sleSlotSystemCPULoadHighThresholdTimer OBJECT-TYPE
SYNTAX INTEGER
{
timerInverval5(1),
timerInverval60(2),
timerInverval600(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The high threshold timer of CPU load (sec) (60:default)"
::= { sleSlotSystemInfoEntry 28 }
sleSlotSystemCPULoadLowThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The low threshold of CPU load (30:default)"
::= { sleSlotSystemInfoEntry 29 }
sleSlotSystemCPULoadLowThresholdTimer OBJECT-TYPE
SYNTAX INTEGER
{
timerInverval5(1),
timerInverval60(2),
timerInverval600(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The low threshold timer of CPU load (sec) (60:default)"
::= { sleSlotSystemInfoEntry 30 }
sleSlotSystemCPULoadCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CPU load currnet value (only used for trap)"
::= { sleSlotSystemInfoEntry 31 }
sleSlotSystemCPUOverallStatus OBJECT-TYPE
SYNTAX INTEGER
{
good(1),
bad(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CPU Overall status for SFU & IU"
::= { sleSlotSystemInfoEntry 32 }
sleSlotSystemTemperOverallStatus OBJECT-TYPE
SYNTAX INTEGER
{
good(1),
bad(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Temperature Overall status for SFU & IU"
::= { sleSlotSystemInfoEntry 33 }
sleSlotSystemControl OBJECT IDENTIFIER ::= { sleSlotSystemInfo 2 }
sleSlotSystemControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setSlotRestart(1),
setSlotCpuloadThreshold(2),
delSlotCpuloadThreshold(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command"
::= { sleSlotSystemControl 1 }
sleSlotSystemControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of user command"
::= { sleSlotSystemControl 2 }
sleSlotSystemControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command"
::= { sleSlotSystemControl 3 }
sleSlotSystemControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)"
::= { sleSlotSystemControl 4 }
sleSlotSystemControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the last user command"
::= { sleSlotSystemControl 5 }
sleSlotSystemControlSlotIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system slot index."
::= { sleSlotSystemControl 6 }
sleSlotSystemControlCPULoadHighThreshold OBJECT-TYPE
SYNTAX Integer32 (21..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The high threshold of CPU load (70:default)"
::= { sleSlotSystemControl 7 }
sleSlotSystemControlCPULoadHighThresholdTimer OBJECT-TYPE
SYNTAX INTEGER
{
timerInverval5(1),
timerInverval60(2),
timerInverval600(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The high threshold timer of CPU load (sec) (60:default)"
::= { sleSlotSystemControl 8 }
sleSlotSystemControlCPULoadLowThreshold OBJECT-TYPE
SYNTAX Integer32 (20..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The low threshold of CPU load (30:default)"
::= { sleSlotSystemControl 9 }
sleSlotSystemControlCPULoadLowThresholdTimer OBJECT-TYPE
SYNTAX INTEGER
{
timerInverval5(1),
timerInverval60(2),
timerInverval600(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The low threshold timer of CPU load (sec) (60:default)"
::= { sleSlotSystemControl 10 }
sleSlotSystemNotification OBJECT IDENTIFIER ::= { sleSlotSystemInfo 3 }
sleSlotSystemRestart NOTIFICATION-TYPE
OBJECTS { sleSlotSystemControlRequest, sleSlotSystemControlTimeStamp, sleSlotSystemControlReqResult, sleSlotSystemControlSlotIndex }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotSystemNotification 1 }
sleSlotSystemCPULoadChagned NOTIFICATION-TYPE
OBJECTS { sleSlotSystemControlRequest, sleSlotSystemControlTimeStamp, sleSlotSystemControlReqResult, sleSlotSystemControlSlotIndex, sleSlotSystemControlCPULoadHighThreshold,
sleSlotSystemControlCPULoadHighThresholdTimer, sleSlotSystemControlCPULoadLowThreshold, sleSlotSystemControlCPULoadLowThresholdTimer }
STATUS current
DESCRIPTION
"setSlotCpuloadThreshold"
::= { sleSlotSystemNotification 2 }
sleSlotSystemCPULoadDeleted NOTIFICATION-TYPE
OBJECTS { sleSlotSystemControlRequest, sleSlotSystemControlTimeStamp, sleSlotSystemControlReqResult, sleSlotSystemControlSlotIndex }
STATUS current
DESCRIPTION
"delSlotCpuloadThreshold"
::= { sleSlotSystemNotification 3 }
sleSlotStatusInfo OBJECT IDENTIFIER ::= { sleSlot 2 }
sleSlotStatusInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleSlotStatusInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleSlotStatusInfo 1 }
sleSlotStatusInfoEntry OBJECT-TYPE
SYNTAX SleSlotStatusInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleSlotSystemIndex }
::= { sleSlotStatusInfoTable 1 }
SleSlotStatusInfoEntry ::=
SEQUENCE {
sleSlotStatusPlan
INTEGER,
sleSlotStatusPlanCardType
INTEGER,
sleSlotStatusCurrentInstall
INTEGER,
sleSlotStatusCurrentInstallCardType
INTEGER,
sleSlotStatusCardOperation
INTEGER,
sleSlotStatusLock
INTEGER,
sleSlotStatusUpgradeMode
INTEGER,
sleSlotStatusActionEvent
INTEGER,
sleSlotStatusState
INTEGER,
sleSlotStatusPower
INTEGER,
sleSlotStatusSerialNumber
OCTET STRING,
sleSlotStatusHealthState
INTEGER,
sleslotStatusOverallState
INTEGER,
sleslotStatusSyncState
INTEGER
}
sleSlotStatusPlan OBJECT-TYPE
SYNTAX INTEGER
{
notPlanned(1),
planned(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Planning status of slot."
::= { sleSlotStatusInfoEntry 1 }
sleSlotStatusPlanCardType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
siuGE12(2),
siuEPON12(3),
siuGPON4(4),
niuGE12(5),
sfu(6),
v5548gGE12(7),
siuGPON4r(8),
niuGE8(9),
siuGE4(10),
niu10GPlus(11),
iu10GE(12),
iuGE6(13),
iuGE4(14),
siuTDM(15),
siuGE24(16),
siuFE48(17),
niu10GE2(18),
siu10GE48(19),
siuGE10(20),
niu10Ge2Plus(21),
iuGT4(22),
iuGT6(23),
iuTDM6(24),
siuGE6(25),
siuGE8(26),
siuGT6(27),
niuGE2(28),
niuGE4(29),
iuGEPON4(30),
iu10GE8(31),
iuGEPON8(32),
iu10GEPON8(33),
iuGE8(34),
siu10GEPON8(35),
niu10GE4(36),
sfu10GE4(37),
siuGPON16(38),
iu10GE4(39),
siuGT24(40),
iu10GE2(41),
cwdm(42),
iuGT8(43)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Planning card type status of slot."
::= { sleSlotStatusInfoEntry 2 }
sleSlotStatusCurrentInstall OBJECT-TYPE
SYNTAX INTEGER
{
notInstalled(1),
installed(2),
failed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Currently installation status of slot."
::= { sleSlotStatusInfoEntry 3 }
sleSlotStatusCurrentInstallCardType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
siuGE12(2),
siuEPON12(3),
siuGPON4(4),
niuGE12(5),
sfu(6),
v5548gGE12(7),
siuGPON4r(8),
niuGE8(9),
siuGE4(10),
niu10GPlus(11),
iuGE10(12),
iuGE6(13),
iuGE4(14),
siuTDM(15),
siuGE24(16),
siuFE48(17),
niu10GE2(18),
siu10GE48(19),
siuGE10(20),
niu10Ge2Plus(21),
iuGT4(22),
iuGT6(23),
iuTDM6(24),
siuGE6(25),
siuGE8(26),
siuGT6(27),
niuGE2(28),
niuGE4(29),
iuGEPON4(30),
iu10GE8(31),
iuGEPON8(32),
iu10GEPON8(33),
iuGE8(34),
siu10GEPON8(35),
niu10GE4(36),
sfu10GE4(37),
siuGPON16(38),
iu10GE4(39),
siuGT24(40),
iu10GE2(41),
cwdm(42),
iuGT8(43)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Currently installation card type status of slot."
::= { sleSlotStatusInfoEntry 4 }
sleSlotStatusCardOperation OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
init(2),
enable(3),
enableActive(4),
enableStandby(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Currently operation status of slot."
::= { sleSlotStatusInfoEntry 5 }
sleSlotStatusLock OBJECT-TYPE
SYNTAX INTEGER
{
unlocked(1),
locked(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lock status of slot."
::= { sleSlotStatusInfoEntry 6 }
sleSlotStatusUpgradeMode OBJECT-TYPE
SYNTAX INTEGER
{
manual(1),
auto(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upgrade mode status of slot."
::= { sleSlotStatusInfoEntry 7 }
sleSlotStatusActionEvent OBJECT-TYPE
SYNTAX INTEGER
{
uninstallAction(1),
installAction(2),
noPlanningAction(3),
planningAction(4),
lockAction(5),
unlockAction(6),
matchedEvent(7),
unMatchedEvent(8),
bootEndEvent(9),
configEndEvent(10),
configFailEvent(11)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Event of slot. (accessible-for-notify)"
::= { sleSlotStatusInfoEntry 8 }
sleSlotStatusState OBJECT-TYPE
SYNTAX INTEGER
{
default(1),
planningWait(2),
installWait(3),
operationReady(4),
actionBootReady(5),
actionConfig(6),
actionEnableReady(7),
actionEnable(8),
actionEnableLock(9),
actionDisable(10)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Status of slot. (accessible-for-notify)"
::= { sleSlotStatusInfoEntry 9 }
sleSlotStatusPower OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Currently power status of slot."
::= { sleSlotStatusInfoEntry 10 }
sleSlotStatusSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number"
::= { sleSlotStatusInfoEntry 11 }
sleSlotStatusHealthState OBJECT-TYPE
SYNTAX INTEGER
{
well(0),
warning(1),
timeout(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot health status"
::= { sleSlotStatusInfoEntry 12 }
sleslotStatusOverallState OBJECT-TYPE
SYNTAX INTEGER
{
good(0),
bad(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot overrall status"
::= { sleSlotStatusInfoEntry 13 }
sleslotStatusSyncState OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
disable(1),
process(2),
done(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot sync status"
::= { sleSlotStatusInfoEntry 14 }
sleSlotStatusControl OBJECT IDENTIFIER ::= { sleSlotStatusInfo 2 }
sleSlotStatusControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setSlotLock(1),
setSlotUnlock(2),
setSlotPlanning(3),
setSlotNoplanning(4),
setSlotUpgradeMode(5),
setSlotPowerUp(6),
setSlotPowerDown(7),
setSlotPowerReset(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command"
::= { sleSlotStatusControl 1 }
sleSlotStatusControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of user command"
::= { sleSlotStatusControl 2 }
sleSlotStatusControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command"
::= { sleSlotStatusControl 3 }
sleSlotStatusControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)"
::= { sleSlotStatusControl 4 }
sleSlotStatusControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the last user command"
::= { sleSlotStatusControl 5 }
sleSlotStatusControlSlotIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system slot index.
255 is means all slot."
::= { sleSlotStatusControl 6 }
sleSlotStatusControlPlanCardType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
siuGE12(2),
siuEPON12(3),
siuGPON4(4),
niuGE12(5),
sfu(6),
v5548gGE12(7),
siuGPON4r(8),
niuGE8(9),
siuGE4(10),
niu10GPlus(11),
iuGE10(12),
iuGE6(13),
iuGE4(14),
siuTDM(15),
siuGE24(16),
siuFE48(17),
niu10GE2(18),
siu10GE48(19),
siuGE10(20),
niu10Ge2Plus(21),
iuGT4(22),
iuGT6(23),
iuTDM6(24),
siuGE6(25),
siuGE8(26),
siuGT6(27),
niuGE2(28),
niuGE4(29),
iuGEPON4(30),
iu10GE8(31),
iuGEPON8(32),
iu10GEPON8(33),
iuGE8(34),
siu10GEPON8(35),
niu10GE4(36),
sfu10GE4(37),
siuGPON16(38),
iu10GE4(39),
siuGT24(40),
iu10GE2(41),
cwdm(42),
iuGT8(43)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Planning card type status of slot."
::= { sleSlotStatusControl 7 }
sleSlotStatusControlUpgradeMode OBJECT-TYPE
SYNTAX INTEGER
{
manual(1),
auto(2),
autoUpgradeManualReset(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Upgrade mode status of slot."
::= { sleSlotStatusControl 8 }
sleSlotStatusNotification OBJECT IDENTIFIER ::= { sleSlotStatusInfo 3 }
sleSlotStatusLocked NOTIFICATION-TYPE
OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotStatusNotification 1 }
sleSlotStatusUnlocked NOTIFICATION-TYPE
OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotStatusNotification 2 }
sleSlotStatusPlanning NOTIFICATION-TYPE
OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex, sleSlotStatusControlPlanCardType
}
STATUS current
DESCRIPTION
"Description."
::= { sleSlotStatusNotification 3 }
sleSlotStatusNoPlanning NOTIFICATION-TYPE
OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotStatusNotification 4 }
sleSlotStatusUpgradeModeChanged NOTIFICATION-TYPE
OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex, sleSlotStatusControlUpgradeMode
}
STATUS current
DESCRIPTION
"Description."
::= { sleSlotStatusNotification 5 }
sleSlotStatusPowerUp NOTIFICATION-TYPE
OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotStatusNotification 6 }
sleSlotStatusPowerDown NOTIFICATION-TYPE
OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotStatusNotification 7 }
sleSlotStatusPowerReset NOTIFICATION-TYPE
OBJECTS { sleSlotStatusControlRequest, sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotStatusNotification 8 }
sleSlotNosInfo OBJECT IDENTIFIER ::= { sleSlot 3 }
sleSlotNosInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleSlotNosInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleSlotNosInfo 1 }
sleSlotNosInfoEntry OBJECT-TYPE
SYNTAX SleSlotNosInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleSlotSystemIndex }
::= { sleSlotNosInfoTable 1 }
SleSlotNosInfoEntry ::=
SEQUENCE {
sleSlotNosVersion
OCTET STRING,
sleSlotNosRevision
OCTET STRING,
sleSlotNosSize
Unsigned32,
sleSlotNosUpgradeStatus
INTEGER,
sleSlotNosStbVersion
OCTET STRING,
sleSlotNosStbRevision
OCTET STRING,
sleSlotNosStbSize
Unsigned32
}
sleSlotNosVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NOS version of slot."
::= { sleSlotNosInfoEntry 1 }
sleSlotNosRevision OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NOS revision of slot."
::= { sleSlotNosInfoEntry 2 }
sleSlotNosSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NOS size of slot."
::= { sleSlotNosInfoEntry 3 }
sleSlotNosUpgradeStatus OBJECT-TYPE
SYNTAX INTEGER
{
upgradeIdle(1),
upgradeStart(2),
upgradeDone(3),
upgradeFail(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NOS upgrade status of slot."
::= { sleSlotNosInfoEntry 4 }
sleSlotNosStbVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Stand by NOS version of slot"
::= { sleSlotNosInfoEntry 5 }
sleSlotNosStbRevision OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Stand by NOS revision of slot."
::= { sleSlotNosInfoEntry 6 }
sleSlotNosStbSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Stand by NOS size of slot."
::= { sleSlotNosInfoEntry 7 }
sleSlotNosControl OBJECT IDENTIFIER ::= { sleSlotNosInfo 2 }
sleSlotNosControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setSlotUpgarde(1),
downloadSlotNos(2),
upgradeSlotBootloader(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command"
::= { sleSlotNosControl 1 }
sleSlotNosControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of user command"
::= { sleSlotNosControl 2 }
sleSlotNosControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command"
::= { sleSlotNosControl 3 }
sleSlotNosControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)"
::= { sleSlotNosControl 4 }
sleSlotNosControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the last user command"
::= { sleSlotNosControl 5 }
sleSlotNosControlSlotIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system slot index."
::= { sleSlotNosControl 6 }
sleSlotNosControlUpDownMethod OBJECT-TYPE
SYNTAX INTEGER
{
ftp(1),
tftp(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"1: using FTP
2: using TFTP
"
::= { sleSlotNosControl 7 }
sleSlotNosControlUpDownFlag OBJECT-TYPE
SYNTAX INTEGER
{
upload(1),
download(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"1. Uploading slot nos to the remote-host.
2. Downloading slot nos from the remote-host."
::= { sleSlotNosControl 8 }
sleSlotNosControlServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The remote-host's IP address."
::= { sleSlotNosControl 9 }
sleSlotNosControlUserID OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Account-name."
::= { sleSlotNosControl 10 }
sleSlotNosControlPassword OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Account-password."
::= { sleSlotNosControl 11 }
sleSlotNosControlFileName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Slot nos file name."
::= { sleSlotNosControl 12 }
sleSlotNosNotification OBJECT IDENTIFIER ::= { sleSlotNosInfo 3 }
sleSlotNosUpgrade NOTIFICATION-TYPE
OBJECTS { sleSlotNosControlRequest, sleSlotNosControlTimeStamp, sleSlotNosControlReqResult, sleSlotNosControlSlotIndex }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotNosNotification 1 }
sleSlotNosDownload NOTIFICATION-TYPE
OBJECTS { sleSlotNosControlRequest, sleSlotNosControlTimeStamp, sleSlotNosControlReqResult, sleSlotNosControlUpDownMethod, sleSlotNosControlUpDownFlag,
sleSlotNosControlServerAddress, sleSlotNosControlUserID, sleSlotNosControlPassword, sleSlotNosControlFileName }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotNosNotification 2 }
sleSlotNosBootloaderUpgrade NOTIFICATION-TYPE
OBJECTS { sleSlotNosControlRequest, sleSlotNosControlTimeStamp, sleSlotNosControlReqResult, sleSlotNosControlSlotIndex, sleSlotNosControlServerAddress,
sleSlotNosControlUserID, sleSlotNosControlPassword, sleSlotNosControlFileName }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotNosNotification 3 }
sleSlotReleasedIUNosInfo OBJECT IDENTIFIER ::= { sleSlot 4 }
sleSlotReleasedNIUNosVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released NIU NOS image version on SFU."
::= { sleSlotReleasedIUNosInfo 1 }
sleSlotReleasedNIUNosRevision OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released NIU NOS image revision on SFU."
::= { sleSlotReleasedIUNosInfo 2 }
sleSlotReleasedNIUNosSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released NIU NOS image size on SFU."
::= { sleSlotReleasedIUNosInfo 3 }
sleSlotReleasedGPIUNosVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released GPIU NOS image version on SFU."
::= { sleSlotReleasedIUNosInfo 4 }
sleSlotReleasedGPIUNosRevision OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released GPIU NOS image revision on SFU."
::= { sleSlotReleasedIUNosInfo 5 }
sleSlotReleasedGPIUNosSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released GPIU NOS image size on SFU."
::= { sleSlotReleasedIUNosInfo 6 }
sleSlotReleasedSIUNosVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released SIU NOS image version on SFU."
::= { sleSlotReleasedIUNosInfo 7 }
sleSlotReleasedSIUNosRevision OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released SIU NOS image revision on SFU."
::= { sleSlotReleasedIUNosInfo 8 }
sleSlotReleasedSIUNosSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released SIU NOS image size on SFU."
::= { sleSlotReleasedIUNosInfo 9 }
sleSlotReleasedIU10GE8NosVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released IU_10GE8 NOS image version on SFU."
::= { sleSlotReleasedIUNosInfo 10 }
sleSlotReleasedIU10GE8NosRevision OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released IU_10GE8 NOS image revision on SFU."
::= { sleSlotReleasedIUNosInfo 11 }
sleSlotReleasedIU10GE8NosSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released IU_10GE8 NOS image size on SFU."
::= { sleSlotReleasedIUNosInfo 12 }
sleSlotReleasedIU10GEPON8NosVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released IU_10GEPON8 NOS image version on SFU."
::= { sleSlotReleasedIUNosInfo 13 }
sleSlotReleasedIU10GEPON8NosRevision OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released IU_10GEPON8 NOS image revision on SFU."
::= { sleSlotReleasedIUNosInfo 14 }
sleSlotReleasedIU10GEPON8NosSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released IU_10GEPON8 NOS image size on SFU."
::= { sleSlotReleasedIUNosInfo 15 }
sleSlotReleasedIUGEPON8NosVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released IU_GEPON8 NOS image version on SFU."
::= { sleSlotReleasedIUNosInfo 16 }
sleSlotReleasedIUGEPON8NosRevision OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released IU_GEPON8 NOS image revision on SFU"
::= { sleSlotReleasedIUNosInfo 17 }
sleSlotReleasedIUGEPON8NosSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Released IU_GEPON8 NOS image size on SFU."
::= { sleSlotReleasedIUNosInfo 18 }
sleSlotPowerMon OBJECT IDENTIFIER ::= { sleSlot 5 }
sleSlotPowerMonTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleSlotPowerMonEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Power-Monitoring table."
::= { sleSlotPowerMon 1 }
sleSlotPowerMonEntry OBJECT-TYPE
SYNTAX SleSlotPowerMonEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Power-Monitoring entry."
INDEX { sleSlotSystemIndex, sleSlotPowerMonIndex }
::= { sleSlotPowerMonTable 1 }
SleSlotPowerMonEntry ::=
SEQUENCE {
sleSlotPowerMonIndex
INTEGER,
sleSlotPowerMonStatus
INTEGER,
sleSlotPowerMonVoltage
Gauge32
}
sleSlotPowerMonIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical index of power-monitoring object."
::= { sleSlotPowerMonEntry 1 }
sleSlotPowerMonStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
good(2),
bad(3),
over(4),
under(5),
overUnder(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The monitoring status of power-monitoring object."
::= { sleSlotPowerMonEntry 2 }
sleSlotPowerMonVoltage OBJECT-TYPE
SYNTAX Gauge32
UNITS "0.1v"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage value of power-monitoring object.
value 10000(1000v) indicate that FUSE."
::= { sleSlotPowerMonEntry 3 }
sleSlotAiu OBJECT IDENTIFIER ::= { sleSlot 6 }
sleSlotAiuRunStatus OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot AIU run status."
::= { sleSlotAiu 1 }
sleSlotAiuAlarmStatus OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot AIU alarm status."
::= { sleSlotAiu 2 }
sleSlotProtection OBJECT IDENTIFIER ::= { sleSlot 7 }
sleSlotProtectionBase OBJECT IDENTIFIER ::= { sleSlotProtection 1 }
sleSlotProtectionInfo OBJECT IDENTIFIER ::= { sleSlotProtectionBase 1 }
sleSlotProtectionSystemStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system admin status(enable or disable) of overtemperature shutdown function."
::= { sleSlotProtectionInfo 1 }
sleSlotProtectionSystemThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system admin threshold of overtemperature shutdown function."
::= { sleSlotProtectionInfo 2 }
sleSlotProtectionIUPowerStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The slot power shutdown status"
::= { sleSlotProtectionInfo 3 }
sleSlotProtectionControl OBJECT IDENTIFIER ::= { sleSlotProtectionBase 2 }
sleSlotProtectionControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setSlotProtectionSystemStatus(1),
setSlotProtectionSystemThresh(2),
setslotProtectionIUPowerStatus(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command"
::= { sleSlotProtectionControl 1 }
sleSlotProtectionControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of user command"
::= { sleSlotProtectionControl 2 }
sleSlotProtectionControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command"
::= { sleSlotProtectionControl 3 }
sleSlotProtectionControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)"
::= { sleSlotProtectionControl 4 }
sleSlotProtectionControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the last user command"
::= { sleSlotProtectionControl 5 }
sleSlotProtectionControlSystemStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system admin status(enable or disable) of overtemperature shutdown function."
::= { sleSlotProtectionControl 6 }
sleSlotProtectionControlSystemThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system admin threshold of overtemperature shutdown function."
::= { sleSlotProtectionControl 7 }
sleSlotProtectionControlIUPowerStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The slot power shutdown status"
::= { sleSlotProtectionControl 8 }
sleSlotProtectionNotification OBJECT IDENTIFIER ::= { sleSlotProtectionBase 3 }
sleSlotProtectionSystemStatusChanged NOTIFICATION-TYPE
OBJECTS { sleSlotProtectionControlRequest, sleSlotProtectionControlTimeStamp, sleSlotProtectionControlReqResult, sleSlotProtectionControlSystemStatus }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotProtectionNotification 1 }
sleSlotProtectionSystemThreshChanged NOTIFICATION-TYPE
OBJECTS { sleSlotProtectionControlRequest, sleSlotProtectionControlTimeStamp, sleSlotProtectionControlReqResult, sleSlotProtectionControlSystemThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotProtectionNotification 2 }
sleSlotProtectionIUPowerStatusChanged NOTIFICATION-TYPE
OBJECTS { sleSlotProtectionControlRequest, sleSlotProtectionControlTimeStamp, sleSlotProtectionControlReqResult, sleSlotProtectionControlIUPowerStatus }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotProtectionNotification 3 }
sleSlotProtectionIU OBJECT IDENTIFIER ::= { sleSlotProtection 2 }
sleSlotProtectionIUTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleSlotProtectionIUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleSlotProtectionIU 1 }
sleSlotProtectionIUEntry OBJECT-TYPE
SYNTAX SleSlotProtectionIUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
AUGMENTS { sleSlotSystemInfoEntry }
::= { sleSlotProtectionIUTable 1 }
SleSlotProtectionIUEntry ::=
SEQUENCE {
sleSlotProtectionIUTemperHighThresh
Integer32,
sleSlotProtectionIUTemperLowThresh
Integer32,
sleSlotProtectionIUPowerThresh
Integer32,
sleSlotProtectionIUTemper
Integer32,
sleSlotProtectionIUTemper2
Integer32
}
sleSlotProtectionIUTemperHighThresh OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Slot temperature High-threshold of overtemperature alarm"
::= { sleSlotProtectionIUEntry 1 }
sleSlotProtectionIUTemperLowThresh OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Slot temperature Low-threshold of overtemperature alarm"
::= { sleSlotProtectionIUEntry 2 }
sleSlotProtectionIUPowerThresh OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Slot temperature threshold of overtemperature power shutdown."
::= { sleSlotProtectionIUEntry 3 }
sleSlotProtectionIUTemper OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Slot temperature."
::= { sleSlotProtectionIUEntry 4 }
sleSlotProtectionIUTemper2 OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Slot temperature2."
::= { sleSlotProtectionIUEntry 5 }
sleSlotProtectionIUControl OBJECT IDENTIFIER ::= { sleSlotProtectionIU 2 }
sleSlotProtectionIUControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setSlotTempThreshold(1),
setSlotPowerThresh(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command"
::= { sleSlotProtectionIUControl 1 }
sleSlotProtectionIUControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of user command"
::= { sleSlotProtectionIUControl 2 }
sleSlotProtectionIUControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command"
::= { sleSlotProtectionIUControl 3 }
sleSlotProtectionIUControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)"
::= { sleSlotProtectionIUControl 4 }
sleSlotProtectionIUControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the last user command"
::= { sleSlotProtectionIUControl 5 }
sleSlotProtectionIUControlindex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the slot index"
::= { sleSlotProtectionIUControl 6 }
sleSlotProtectionIUControlTemperHighThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Slot temperature High-threshold of overtemperature alarm"
::= { sleSlotProtectionIUControl 7 }
sleSlotProtectionIUControlTemperLowThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Slot temperature Low-threshold of overtemperature alarm"
::= { sleSlotProtectionIUControl 8 }
sleSlotProtectionIUControlPowerThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Slot temperature threshold of overtemperature power shutdown."
::= { sleSlotProtectionIUControl 9 }
sleSlotProtectionIUNotification OBJECT IDENTIFIER ::= { sleSlotProtectionIU 3 }
sleSlotProtectionIUTemperThreshChanged NOTIFICATION-TYPE
OBJECTS { sleSlotProtectionIUControlRequest, sleSlotProtectionIUControlTimeStamp, sleSlotProtectionIUControlReqResult, sleSlotProtectionIUControlTemperHighThresh, sleSlotProtectionIUControlTemperLowThresh,
sleSlotProtectionIUControlindex }
STATUS current
DESCRIPTION
"Description."
::= { sleSlotProtectionIUNotification 1 }
sleSlotProtectionIUPowerThreshChanged NOTIFICATION-TYPE
OBJECTS { sleSlotProtectionIUControlRequest, sleSlotProtectionIUControlTimeStamp, sleSlotProtectionIUControlReqResult, sleSlotProtectionIUControlindex, sleSlotProtectionIUControlPowerThresh
}
STATUS current
DESCRIPTION
"Description."
::= { sleSlotProtectionIUNotification 2 }
sleRF OBJECT IDENTIFIER ::= { sleDevice 12 }
sleRfBaseInfo OBJECT IDENTIFIER ::= { sleRF 1 }
sleRfConnectStatus OBJECT-TYPE
SYNTAX INTEGER
{
connect(1),
disconnect(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RF connect status."
::= { sleRfBaseInfo 1 }
sleRfPowerStatus OBJECT-TYPE
SYNTAX INTEGER
{
poweroff(0),
poweron(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RF power status."
::= { sleRfBaseInfo 2 }
sleRfEthertype OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RF ethertype."
::= { sleRfBaseInfo 3 }
sleRfSrcAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RF source address."
::= { sleRfBaseInfo 4 }
sleRfDesAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RF destination address."
::= { sleRfBaseInfo 5 }
sleRfBaseControl OBJECT IDENTIFIER ::= { sleRF 2 }
sleRfBaseControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setRfEthertype(1),
resetRfEthertype(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command."
::= { sleRfBaseControl 1 }
sleRfBaseControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of user command."
::= { sleRfBaseControl 2 }
sleRfBaseControlTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command."
::= { sleRfBaseControl 3 }
sleRfBaseControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)."
::= { sleRfBaseControl 4 }
sleRfBaseControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of user command."
::= { sleRfBaseControl 5 }
sleRfBaseControlRfEthertype OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Rf ethertype ,the format is 0xXXXX, default value is 0x8864."
::= { sleRfBaseControl 6 }
sleRfBaseNotification OBJECT IDENTIFIER ::= { sleRF 3 }
sleRFBaseEthertypeChanged NOTIFICATION-TYPE
OBJECTS { sleRfBaseControlRequest, sleRfBaseControlTimeStamp, sleRfBaseControlReqResult, sleRfBaseControlRfEthertype }
STATUS current
DESCRIPTION
"Description."
::= { sleRfBaseNotification 1 }
sleRFBaseEthertypeResetChanged NOTIFICATION-TYPE
OBJECTS { sleRfBaseControlRequest, sleRfBaseControlTimeStamp, sleRfBaseControlReqResult, sleRfBaseControlRfEthertype }
STATUS current
DESCRIPTION
"Description."
::= { sleRfBaseNotification 2 }
sleRfPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleRfPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleRF 4 }
sleRfPortEntry OBJECT-TYPE
SYNTAX SleRfPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleRfPortIndex }
::= { sleRfPortTable 1 }
SleRfPortEntry ::=
SEQUENCE {
sleRfPortIndex
INTEGER,
sleRfPortAdminStatus
INTEGER,
sleRfPortOperStatus
INTEGER
}
sleRfPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..256)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RF port index."
::= { sleRfPortEntry 1 }
sleRfPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
na(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RF port adminStatus."
::= { sleRfPortEntry 2 }
sleRfPortOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
na(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RF port operStatus."
::= { sleRfPortEntry 3 }
sleRFPortControl OBJECT IDENTIFIER ::= { sleRF 5 }
sleRfPortControlRequest OBJECT-TYPE
SYNTAX INTEGER { setRfPortStatus(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command."
::= { sleRFPortControl 1 }
sleRfPortControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of user command."
::= { sleRFPortControl 2 }
sleRfPortControlTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command."
::= { sleRFPortControl 3 }
sleRfPortControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)."
::= { sleRFPortControl 4 }
sleRfPortControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of user command.
"
::= { sleRFPortControl 5 }
sleRfPortControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RF port index <1-8>."
::= { sleRFPortControl 6 }
sleRfPortControlAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RF port adminStatus."
::= { sleRFPortControl 7 }
sleRFPortNotification OBJECT IDENTIFIER ::= { sleRF 6 }
sleRfPortStatusChanged NOTIFICATION-TYPE
OBJECTS { sleRfPortControlRequest, sleRfPortControlTimeStamp, sleRfPortControlReqResult, sleRfPortControlIndex, sleRfPortControlAdminStatus
}
STATUS current
DESCRIPTION
"Description."
::= { sleRFPortNotification 1 }
sleEnvironmentMonitor OBJECT IDENTIFIER ::= { sleDevice 13 }
sleEMTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleEMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleEnvironmentMonitor 1 }
sleEMEntry OBJECT-TYPE
SYNTAX SleEMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleEMInputIndex }
::= { sleEMTable 1 }
SleEMEntry ::=
SEQUENCE {
sleEMInputIndex
Integer32,
sleEMAlarmString
OCTET STRING,
sleEMAlarmSeverity
INTEGER,
sleEMmode
INTEGER
}
sleEMInputIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The environment monitoring input index(1-4)."
::= { sleEMEntry 1 }
sleEMAlarmString OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm string"
::= { sleEMEntry 2 }
sleEMAlarmSeverity OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm severity."
::= { sleEMEntry 3 }
sleEMmode OBJECT-TYPE
SYNTAX INTEGER
{
normalClose(0),
normalOpen(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The environment monitoring mode.(default:normal-close)"
::= { sleEMEntry 4 }
sleEMControl OBJECT IDENTIFIER ::= { sleEnvironmentMonitor 2 }
sleEMControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setEM(1),
delEM(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command."
::= { sleEMControl 1 }
sleEMControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEMControl 2 }
sleEMControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command.
Apply your setting.
"
::= { sleEMControl 3 }
sleEMControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEMControl 4 }
sleEMControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEMControl 5 }
sleEMControlInputIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The environment monitoring input index(1-4)."
::= { sleEMControl 6 }
sleEMControlAlarmString OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The alarm string"
::= { sleEMControl 7 }
sleEMControlAlarmSeverity OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The alarm severity."
::= { sleEMControl 8 }
sleEMControlmode OBJECT-TYPE
SYNTAX INTEGER
{
normalClose(0),
normalOpen(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The environment monitoring mode.(default:normal-close)"
::= { sleEMControl 9 }
sleEMNotification OBJECT IDENTIFIER ::= { sleEnvironmentMonitor 3 }
sleEMChanged NOTIFICATION-TYPE
OBJECTS { sleEMControlRequest, sleEMControlTimeStamp, sleEMControlReqResult, sleEMControlInputIndex, sleEMControlAlarmString,
sleEMControlAlarmSeverity, sleEMControlmode }
STATUS current
DESCRIPTION
"Description."
::= { sleEMNotification 1 }
sleEMDeleted NOTIFICATION-TYPE
OBJECTS { sleEMControlRequest, sleEMControlTimeStamp, sleEMControlReqResult, sleEMControlInputIndex }
STATUS current
DESCRIPTION
"Description."
::= { sleEMNotification 2 }
sleBypass OBJECT IDENTIFIER ::= { sleDevice 14 }
sleBypassBase OBJECT IDENTIFIER ::= { sleBypass 1 }
sleBypassBaseInfo OBJECT IDENTIFIER ::= { sleBypassBase 1 }
sleBypassMode OBJECT-TYPE
SYNTAX INTEGER
{
on(1),
off(2),
auto(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"optic bypass mode"
DEFVAL { 2 }
::= { sleBypassBaseInfo 1 }
sleBypassStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"optic bypass status
"
::= { sleBypassBaseInfo 2 }
sleBypassBaseControl OBJECT IDENTIFIER ::= { sleBypassBase 2 }
sleBypassBaseControlRequest OBJECT-TYPE
SYNTAX INTEGER { setBypassMode(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleBypassBaseControl 1 }
sleBypassBaseControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of user command."
::= { sleBypassBaseControl 2 }
sleBypassBaseControlTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command."
::= { sleBypassBaseControl 3 }
sleBypassBaseControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)."
::= { sleBypassBaseControl 4 }
sleBypassBaseControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of user command."
::= { sleBypassBaseControl 5 }
sleBypassBaseControlMode OBJECT-TYPE
SYNTAX INTEGER
{
on(1),
off(2),
auto(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"optic bypass mode"
::= { sleBypassBaseControl 6 }
sleBypassBaseNotification OBJECT IDENTIFIER ::= { sleBypassBase 3 }
sleBypassModeChanged NOTIFICATION-TYPE
OBJECTS { sleBypassBaseControlRequest, sleBypassBaseControlTimeStamp, sleBypassBaseControlReqResult, sleBypassBaseControlMode }
STATUS current
DESCRIPTION
"setBypassMode(1)"
::= { sleBypassBaseNotification 1 }
sleBypassOption OBJECT IDENTIFIER ::= { sleBypass 2 }
sleBypassOptionConnectivityTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleBypassOptionConnectivityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The connectivity option of bypass"
::= { sleBypassOption 1 }
sleBypassOptionConnectivityEntry OBJECT-TYPE
SYNTAX SleBypassOptionConnectivityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleBypassOptionConnectivityAddress, sleBypassOptionConnectivityPort }
::= { sleBypassOptionConnectivityTable 1 }
SleBypassOptionConnectivityEntry ::=
SEQUENCE {
sleBypassOptionConnectivityAddress
IpAddress,
sleBypassOptionConnectivityPort
Integer32
}
sleBypassOptionConnectivityAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The target IP address of bypass health-checking"
::= { sleBypassOptionConnectivityEntry 1 }
sleBypassOptionConnectivityPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The target port of bypass health-checking."
::= { sleBypassOptionConnectivityEntry 2 }
sleBypassOptionConnectivityControl OBJECT IDENTIFIER ::= { sleBypassOption 2 }
sleBypassOptionConnectivityControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setBypassConnectivity(1),
unsetBypassConnectivity(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"setBypassConnectivity(1) : bypass-check-option connectivity (A.B.C.D) PORT
unsetBypassConnectivity(2) : no bypass-check option connectivity"
::= { sleBypassOptionConnectivityControl 1 }
sleBypassOptionConnectivityControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of user command."
::= { sleBypassOptionConnectivityControl 2 }
sleBypassOptionConnectivityControlTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command."
::= { sleBypassOptionConnectivityControl 3 }
sleBypassOptionConnectivityControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)."
::= { sleBypassOptionConnectivityControl 4 }
sleBypassOptionConnectivityControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of user command."
::= { sleBypassOptionConnectivityControl 5 }
sleBypassOptionConnectivityControlAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The target IP address of bypass health-checking"
::= { sleBypassOptionConnectivityControl 6 }
sleBypassOptionConnectivityControlPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"he target port of bypass health-checking"
::= { sleBypassOptionConnectivityControl 7 }
sleBypassOptionConnectivityNotification OBJECT IDENTIFIER ::= { sleBypassOption 3 }
sleBypassOptionConnectivitySet NOTIFICATION-TYPE
OBJECTS { sleBypassOptionConnectivityControlRequest, sleBypassOptionConnectivityControlTimeStamp, sleBypassOptionConnectivityControlReqResult, sleBypassOptionConnectivityControlAddress, sleBypassOptionConnectivityControlPort
}
STATUS current
DESCRIPTION
"Description."
::= { sleBypassOptionConnectivityNotification 1 }
sleBypassOptionConnectivityUnset NOTIFICATION-TYPE
OBJECTS { sleBypassOptionConnectivityControlRequest, sleBypassOptionConnectivityControlTimeStamp, sleBypassOptionConnectivityControlReqResult, sleBypassOptionConnectivityControlAddress, sleBypassOptionConnectivityControlPort
}
STATUS current
DESCRIPTION
"Description."
::= { sleBypassOptionConnectivityNotification 2 }
sleBypassOptionPingTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleBypassOptionPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleBypassOption 4 }
sleBypassOptionPingEntry OBJECT-TYPE
SYNTAX SleBypassOptionPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleBypassOptionPingAddress }
::= { sleBypassOptionPingTable 1 }
SleBypassOptionPingEntry ::=
SEQUENCE {
sleBypassOptionPingAddress
IpAddress,
sleBypassOptionPingTransInterval
Integer32,
sleBypassOptionPingTranNumber
Integer32,
sleBypassOptionPingReqInterval
Integer32,
sleBypassOptionPingReqTimeout
Integer32,
sleBypassOptionPingLossThresh
Integer32
}
sleBypassOptionPingAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The target IP address of bypass ping health checking"
::= { sleBypassOptionPingEntry 1 }
sleBypassOptionPingTransInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ping transaction interval"
::= { sleBypassOptionPingEntry 2 }
sleBypassOptionPingTranNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ping transaction request number"
::= { sleBypassOptionPingEntry 3 }
sleBypassOptionPingReqInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ping request interval"
::= { sleBypassOptionPingEntry 4 }
sleBypassOptionPingReqTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ping request timeout"
::= { sleBypassOptionPingEntry 5 }
sleBypassOptionPingLossThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ping loss threshold"
::= { sleBypassOptionPingEntry 6 }
sleBypassOptionPingControl OBJECT IDENTIFIER ::= { sleBypassOption 5 }
sleBypassOptionPingControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setBypassPing(1),
unsetBypassPing(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command."
::= { sleBypassOptionPingControl 1 }
sleBypassOptionPingControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of user command."
::= { sleBypassOptionPingControl 2 }
sleBypassOptionPingControlTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command."
::= { sleBypassOptionPingControl 3 }
sleBypassOptionPingControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)."
::= { sleBypassOptionPingControl 4 }
sleBypassOptionPingControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of user command."
::= { sleBypassOptionPingControl 5 }
sleBypassOptionPingControlAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The target IP address of bypass ping health-checking"
::= { sleBypassOptionPingControl 6 }
sleBypassOptionPingControlTransInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ping transaction interval"
::= { sleBypassOptionPingControl 7 }
sleBypassOptionPingControlTranNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ping transaction request number"
::= { sleBypassOptionPingControl 8 }
sleBypassOptionPingControlReqInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ping request interval"
::= { sleBypassOptionPingControl 9 }
sleBypassOptionPingControlReqTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ping request timeout"
::= { sleBypassOptionPingControl 10 }
sleBypassOptionPingControlLossThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ping loss threshold"
::= { sleBypassOptionPingControl 11 }
sleBypassOptionPingNotification OBJECT IDENTIFIER ::= { sleBypassOption 6 }
sleBypassOptionPingSet NOTIFICATION-TYPE
OBJECTS { sleBypassOptionPingControlRequest, sleBypassOptionPingControlTimeStamp, sleBypassOptionPingControlReqResult, sleBypassOptionPingControlTranNumber, sleBypassOptionPingControlReqInterval,
sleBypassOptionPingControlReqTimeout, sleBypassOptionPingControlLossThresh, sleBypassOptionPingControlAddress, sleBypassOptionPingControlTransInterval }
STATUS current
DESCRIPTION
"Description."
::= { sleBypassOptionPingNotification 1 }
sleBypassOptionPingUnset NOTIFICATION-TYPE
OBJECTS { sleBypassOptionPingControlRequest, sleBypassOptionPingControlTimeStamp, sleBypassOptionPingControlReqResult, sleBypassOptionPingControlAddress }
STATUS current
DESCRIPTION
"Description."
::= { sleBypassOptionPingNotification 2 }
sleBypassOptionLinkMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleBypassOptionLinkMonitorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleBypassOption 7 }
sleBypassOptionLinkMonitorEntry OBJECT-TYPE
SYNTAX SleBypassOptionLinkMonitorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleBypassOptionLinkMonitorPort }
::= { sleBypassOptionLinkMonitorTable 1 }
SleBypassOptionLinkMonitorEntry ::=
SEQUENCE {
sleBypassOptionLinkMonitorPort
Integer32,
sleBypassOptionLinkMonitorPortStatus
INTEGER
}
sleBypassOptionLinkMonitorPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port of bypass link health-checking"
::= { sleBypassOptionLinkMonitorEntry 1 }
sleBypassOptionLinkMonitorPortStatus OBJECT-TYPE
SYNTAX INTEGER { enable(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port status of bypass link health-checking"
::= { sleBypassOptionLinkMonitorEntry 2 }
sleBypassOptionLinkMonitorControl OBJECT IDENTIFIER ::= { sleBypassOption 8 }
sleBypassOptionLinkMonitorControlRequest OBJECT-TYPE
SYNTAX INTEGER { setBypassLinkMonitor(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command."
::= { sleBypassOptionLinkMonitorControl 1 }
sleBypassOptionLinkMonitorControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of user command."
::= { sleBypassOptionLinkMonitorControl 2 }
sleBypassOptionLinkMonitorControlTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command."
::= { sleBypassOptionLinkMonitorControl 3 }
sleBypassOptionLinkMonitorControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)."
::= { sleBypassOptionLinkMonitorControl 4 }
sleBypassOptionLinkMonitorControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of user command."
::= { sleBypassOptionLinkMonitorControl 5 }
sleBypassOptionLinkMonitorControlPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port of bypass link health-checking"
::= { sleBypassOptionLinkMonitorControl 6 }
sleBypassOptionLinkMonitorControlPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port status of bypass link health-checking"
::= { sleBypassOptionLinkMonitorControl 7 }
sleBypassOptioLinkMonitorNotification OBJECT IDENTIFIER ::= { sleBypassOption 9 }
sleBypassOptionLinkMonitorChanged NOTIFICATION-TYPE
OBJECTS { sleBypassOptionLinkMonitorControlRequest, sleBypassOptionLinkMonitorControlStatus, sleBypassOptionLinkMonitorControlTimeStamp, sleBypassOptionLinkMonitorControlReqResult, sleBypassOptionLinkMonitorControlPort,
sleBypassOptionLinkMonitorControlPortStatus }
STATUS current
DESCRIPTION
"Description."
::= { sleBypassOptioLinkMonitorNotification 1 }
sleHFC OBJECT IDENTIFIER ::= { sleDevice 15 }
sleHFCTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleHFCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleHFC 1 }
sleHFCEntry OBJECT-TYPE
SYNTAX SleHFCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleHFCOptic1550OTX }
::= { sleHFCTable 1 }
SleHFCEntry ::=
SEQUENCE {
sleHFCOptic1550OTX
OCTET STRING,
sleHFCOptic1550OTXAlarm
INTEGER,
sleHFCOpticUpstreamOTX
OCTET STRING,
sleHFCOpticUpstreamOTXAlarm
INTEGER,
sleHFCOpticDownstreamORX
OCTET STRING,
sleHFCOpticDownstreamORXAlarm
INTEGER,
sleHFCEDFA1OTX
OCTET STRING,
sleHFCEDFA1OTXAlarm
INTEGER,
sleHFCEDFA1ORX
OCTET STRING,
sleHFCEDFA1ORXAlarm
INTEGER,
sleHFCEDFA1LD1Current
OCTET STRING,
sleHFCEDFA1LD1CurrentAlarm
INTEGER,
sleHFCEDFA1LD2Current
OCTET STRING,
sleHFCEDFA1LD2CurrentAlarm
INTEGER,
sleHFCEDFA1LD1Temp
OCTET STRING,
sleHFCEDFA1LD1TempAlarm
INTEGER,
sleHFCEDFA1LD2Temp
OCTET STRING,
sleHFCEDFA1LD2TempAlarm
INTEGER,
sleHFCEDFA1CaseTemp
OCTET STRING,
sleHFCEDFA1CaseTempAlarm
INTEGER,
sleHFCEDFA2OTX
OCTET STRING,
sleHFCEDFA2OTXAarm
INTEGER,
sleHFCEDFA2ORX
OCTET STRING,
sleHFCEDFA2ORXAlarm
INTEGER,
sleHFCEDFA2LD1Current
OCTET STRING,
sleHFCEDFA2LD1CurrentAlarm
INTEGER,
sleHFCEDFA2LD2Current
OCTET STRING,
sleHFCEDFA2LD2CurrentAlarm
INTEGER,
sleHFCEDFA2LD1Temp
OCTET STRING,
sleHFCEDFA2LD1TempAlarm
INTEGER,
sleHFCEDFA2LD2Temp
OCTET STRING,
sleHFCEDFA2LD2TempAlarm
INTEGER,
sleHFCEDFA2CaseTemp
OCTET STRING,
sleHFCEDFA2CaseTempAlarm
INTEGER
}
sleHFCOptic1550OTX OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC Optic 1550 OTX value."
::= { sleHFCEntry 1 }
sleHFCOptic1550OTXAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC Optic 1550 OTX alarm status."
::= { sleHFCEntry 2 }
sleHFCOpticUpstreamOTX OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC Optic Upstream OTX value."
::= { sleHFCEntry 3 }
sleHFCOpticUpstreamOTXAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC Optic Upstream OTX alarm status."
::= { sleHFCEntry 4 }
sleHFCOpticDownstreamORX OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC Optic Downstream ORX value."
::= { sleHFCEntry 5 }
sleHFCOpticDownstreamORXAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC Optic Downstream ORX alarm status."
::= { sleHFCEntry 6 }
sleHFCEDFA1OTX OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 OTX value."
::= { sleHFCEntry 7 }
sleHFCEDFA1OTXAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 OTX alarm status."
::= { sleHFCEntry 8 }
sleHFCEDFA1ORX OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 ORX value."
::= { sleHFCEntry 9 }
sleHFCEDFA1ORXAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 ORX alarm status."
::= { sleHFCEntry 10 }
sleHFCEDFA1LD1Current OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 LD1 Current value."
::= { sleHFCEntry 11 }
sleHFCEDFA1LD1CurrentAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 LD1 Current alarm status."
::= { sleHFCEntry 12 }
sleHFCEDFA1LD2Current OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 LD2 Current value."
::= { sleHFCEntry 13 }
sleHFCEDFA1LD2CurrentAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 LD2 Current alarm status."
::= { sleHFCEntry 14 }
sleHFCEDFA1LD1Temp OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 LD1 Temp value."
::= { sleHFCEntry 15 }
sleHFCEDFA1LD1TempAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 LD1 Temp alarm status."
::= { sleHFCEntry 16 }
sleHFCEDFA1LD2Temp OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 LD2 Temp value."
::= { sleHFCEntry 17 }
sleHFCEDFA1LD2TempAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 LD2 Temp alarm status."
::= { sleHFCEntry 18 }
sleHFCEDFA1CaseTemp OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 Case Temp value."
::= { sleHFCEntry 19 }
sleHFCEDFA1CaseTempAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA1 Case Temp alarm status."
::= { sleHFCEntry 20 }
sleHFCEDFA2OTX OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 OTX value."
::= { sleHFCEntry 21 }
sleHFCEDFA2OTXAarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 OTX alarm status."
::= { sleHFCEntry 22 }
sleHFCEDFA2ORX OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 ORX value."
::= { sleHFCEntry 23 }
sleHFCEDFA2ORXAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 ORX alarm status."
::= { sleHFCEntry 24 }
sleHFCEDFA2LD1Current OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 LD1 Current value."
::= { sleHFCEntry 25 }
sleHFCEDFA2LD1CurrentAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 LD1 Current alarm status."
::= { sleHFCEntry 26 }
sleHFCEDFA2LD2Current OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 LD2 Current value."
::= { sleHFCEntry 27 }
sleHFCEDFA2LD2CurrentAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 LD2 Current alarm status."
::= { sleHFCEntry 28 }
sleHFCEDFA2LD1Temp OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 LD1 Temp value."
::= { sleHFCEntry 29 }
sleHFCEDFA2LD1TempAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 LD1 Temp alarm status."
::= { sleHFCEntry 30 }
sleHFCEDFA2LD2Temp OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 LD2 Temp value."
::= { sleHFCEntry 31 }
sleHFCEDFA2LD2TempAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 LD2 Temp alarm status."
::= { sleHFCEntry 32 }
sleHFCEDFA2CaseTemp OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 Case Temp value."
::= { sleHFCEntry 33 }
sleHFCEDFA2CaseTempAlarm OBJECT-TYPE
SYNTAX INTEGER
{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HFC EDFA2 Case Temp alarm status."
::= { sleHFCEntry 34 }
sleHFCControl OBJECT IDENTIFIER ::= { sleHFC 2 }
sleHFCControlRequest OBJECT-TYPE
SYNTAX INTEGER { setHFCAlarmStatus(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command"
::= { sleHFCControl 1 }
sleHFCControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of user command"
::= { sleHFCControl 2 }
sleHFCControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command."
::= { sleHFCControl 3 }
sleHFCControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)"
::= { sleHFCControl 4 }
sleHFCControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the last user command"
::= { sleHFCControl 5 }
sleHFCControlAlarmIndex OBJECT-TYPE
SYNTAX INTEGER
{
hfcefda1(0),
hfcefda2(1),
hfcoptic(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The HFC alarm index , edfa1 /edfa2 /optic ."
::= { sleHFCControl 6 }
sleHFCControlAlarmStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The HFC alrm status."
::= { sleHFCControl 7 }
sleHFCNotification OBJECT IDENTIFIER ::= { sleHFC 3 }
sleHFCOpticAlarmStatusChanged NOTIFICATION-TYPE
OBJECTS { sleHFCControlRequest, sleHFCControlTimeStamp, sleHFCControlReqResult, sleHFCControlAlarmIndex, sleHFCControlAlarmStatus
}
STATUS current
DESCRIPTION
"HFC Alarm Status Changed."
::= { sleHFCNotification 1 }
sleDeviceGroup OBJECT-GROUP
OBJECTS { sleRfConnectStatus, sleRfPortIndex, sleRfPortAdminStatus, sleRfPortOperStatus, sleDeviceEthernetPortNum,
sleDevicePowerNum, sleDeviceFanModuleNum, sleDeviceTemperatureNum, sleDeviceFanStartTemperature, sleDeviceFanStopTemperature,
sleDeviceControlRequest, sleDeviceControlStatus, sleDeviceControlTimer, sleDeviceControlTimeStamp, sleDeviceControlReqResult,
sleDeviceControlFanStartTemperature, sleDeviceControlFanStopTemperature, sleEthernetPortIndex, sleEthernetPortPhyIndex, sleEthernetPortType,
sleEthernetPortAdminStatus, sleEthernetPortOperStatus, sleEthernetPortTransmissionRate, sleEthernetPortDuplexMode, sleEthernetPortFlowControl,
sleEthernetPortNegotiationMode, sleEthernetPortJumboFrameSize, sleEthernetPortSfpTransceiver, sleEthernetPortSfpVendorName, sleEthernetPortSfpVendorPartNumber,
sleEthernetPortSfpVendorRevision, sleEthernetPortSfpVendorSerialNumber, sleEthernetPortSfpDateCode, sleEthernetPortPhysicalRemoteChassis, sleEthernetPortPhysicalRemoteSlot,
sleEthernetPortPhysicalRemotePort, sleEthernetPortPhysicalLinkDiscoveryMode, sleEthernetPortControlRequest, sleEthernetPortControlStatus, sleEthernetPortControlTimer,
sleEthernetPortControlTimeStamp, sleEthernetPortControlReqResult, sleEthernetPortControlIndex, sleEthernetPortControlType, sleEthernetPortControlAdminStatus,
sleEthernetPortControlTransmissionRate, sleEthernetPortControlDuplexMode, sleEthernetPortControlFlowControl, sleEthernetPortControlJumboFrameSize, sleEthernetPortControlPhysicalRemoteChassis,
sleEthernetPortControlPhysicalRemoteSlot, sleEthernetPortControlPhysicalRemotePort, sleEthernetPortControlPhysicalLinkDiscoveryMode, slePowerIndex, slePowerPhyIndex,
slePowerState, sleFanModuleIndex, sleFanModulePhyIndex, sleFanModuleUnitNum, sleFanModuleAdminState,
sleFanModuleControlRequest, sleFanModuleControlStatus, sleFanModuleControlTimer, sleFanModuleControlTimeStamp, sleFanModuleControlReqResult,
sleFanModuleControlIndex, sleFanModuleControlAdminState, sleFanUnitIndex, sleFanUnitOperState, sleTemperatureIndex,
sleTemperatureState, sleTemperatureValue, sleBatteryIndex, sleDoorStatus, sleOperationPowerType,
sleOperationPowerInfo, slePSUACPowerState, slePSUTemperture, slePSUOutVoltage, slePSUOverTemp,
slePSUFirmwareVer, sleRBUEquipState, sleRBUModeStaus, sleBatteryBackupFile, sleBatteryBackupControlRequest,
sleBatteryBackupControlStatus, sleBatteryBackupControlTimer, sleBatteryBackupControlTimeStamp, sleBatteryBackupControlReqResult, sleBatteryBackupControlServerIP,
sleBatteryBackupControlUserID, sleBatteryBackupControlPassword, sleBatteryBackupControlFlag, sleBatteryBackupControlLocalFile, sleBatteryBackupControlRemoteFile,
sleCpuProcessor, sleCpuModel, sleCpuRevision, sleCpuBogomips, sleCpuManufacturer,
sleCpuClock, sleCpuBusClock, sleRBUTemperature1, slePSUTempThreshold, sleRBUTemperature2,
sleRBUOutVoltage, sleRBUChargeCurrent, sleRBURemainCapacity, sleRBUOverTemp, sleBatteryLow,
sleRBUBTStatus, sleRBUBTThreshold, sleRBURechargeVoltage, sleBatteryCellStatus, sleBPSUACHardwareVer,
sleBatteryControlRequest, sleBatteryControlStatus, sleBatteryControlTimer, sleBatteryControlTimeStamp, sleBatteryControlReqResult,
sleBatteryControlRBUBTStatus, sleBatteryControlRBUBTThreshold, sleBatteryControlRBURechargeVoltage, sleBatteryControlTemperThresh1, sleBatteryControlTemperThresh2,
sleRBUTempHighThreshold, slePowerType, sleClockModuleIndex, sleClockModuleBoardId, sleClockModuleInstallStatus,
sleClockModuleInitStatus, sleSlotSystemIndex, sleSlotSystemUptime, sleSlotSystemModelName, sleSlotSystemSerialNumber,
sleSlotSystemHWVersion, sleSlotSystemBLVersion, sleSlotSystemSWCompatibility, sleSlotSystemOSVersion, sleSlotSystemMacAddress,
sleSlotSystemCPULoadAll, sleSlotSystemCPULoadInterrupt, sleSlotSystemMemoryTotal, sleSlotSystemMemoryFree, sleSlotSystemMemoryShared,
sleSlotSystemMemoryBuffers, sleSlotSystemMemoryCached, sleSlotSystemMemorySwapTotal, sleSlotSystemMemorySwapFree, sleSlotSystemBootReason,
sleSlotSystemBootTime, sleSlotSystemVoltage, sleSlotSystemControlRequest, sleSlotSystemControlStatus, sleSlotSystemControlTimer,
sleSlotSystemControlTimeStamp, sleSlotSystemControlReqResult, sleSlotSystemControlSlotIndex, sleSlotStatusPlan, sleSlotStatusPlanCardType,
sleSlotStatusCurrentInstall, sleSlotStatusCurrentInstallCardType, sleSlotStatusCardOperation, sleSlotStatusLock, sleSlotStatusUpgradeMode,
sleSlotStatusActionEvent, sleSlotStatusState, sleSlotStatusControlRequest, sleSlotStatusControlStatus, sleSlotStatusControlTimer,
sleSlotStatusControlTimeStamp, sleSlotStatusControlReqResult, sleSlotStatusControlSlotIndex, sleSlotStatusControlPlanCardType, sleSlotStatusControlUpgradeMode,
sleSlotNosVersion, sleSlotNosRevision, sleSlotNosSize, sleSlotNosUpgradeStatus, sleSlotNosControlRequest,
sleSlotNosControlStatus, sleSlotNosControlTimer, sleSlotNosControlTimeStamp, sleSlotNosControlReqResult, sleSlotNosControlSlotIndex,
sleSlotReleasedNIUNosVersion, sleSlotReleasedNIUNosRevision, sleSlotReleasedNIUNosSize, sleSlotReleasedGPIUNosVersion, sleSlotReleasedGPIUNosRevision,
sleSlotReleasedGPIUNosSize, sleSlotSystemPowerLevelStatus, sleSlotPowerMonStatus, sleSlotPowerMonVoltage, sleEthernetPortDMIIndex,
sleEthernetPortDMITemper, sleEthernetPortDMIVoltage, sleEthernetPortDMITxBias, sleEthernetPortDMITxPower, sleEthernetPortDMIRxPower,
sleEthernetPortSfpTransceiverType, sleSlotNosControlUpDownMethod, sleSlotNosControlUpDownFlag, sleSlotNosControlServerAddress, sleSlotNosControlUserID,
sleSlotNosControlPassword, sleSlotNosControlFileName, sleFanUnitSpeed, sleSlotSystemInfoLEDStatus, sleFanModuleSpeedThreshold,
sleFanModuleControlSpeedThreshold, sleEthernetPortSfpTransceiverDetailType, sleClockModuleOPMode, sleClockInfoInSrcType, sleClockInfoInSrcAISStatus,
sleClockInfoInSrcLoSStatus, sleClockInfoInSrcLDSCStatus, sleClockInfoInSrcNtrClockType, sleDeviceJumboFrameStatus, sleDeviceControlJumboFrameStatus,
slePowerPSUType, sleSlotSystemInfoPackageVersion, sleEthernetSfpIndex, sleEthernetSfpTransceiver, sleEthernetSfpVendorName,
sleEthernetSfpVendorPartNumber, sleEthernetSfpDateCode, sleEthernetSfpTransceiverType, sleEthernetSfpTransceiverDetailType, sleTemperatureHighThreshold,
sleTemperatureLowThreshold, sleTemperatureControlRequest, sleTemperatureControlStatus, sleTemperatureControlTimer, sleTemperatureControlTimeStamp,
sleTemperatureControlReqResult, sleTemperatureControlIndex, sleTemperatureControlHighThreshold, sleTemperatureControlLowThreshold, sleEthernetSFPControlRequest,
sleEthernetSFPControlStatus, sleEthernetSFPControlTimer, sleEthernetSFPControlTimeStamp, sleEthernetSFPControlReqResult, sleEthernetSFPControlIndex,
sleTemperatureWarnHighThreshold, sleTemperatureWarnLowThreshold, sleTemperatureWarnDuration, sleTemperatureAlarmHighThreshold, sleTemperatureAlarmLowThreshold,
sleTemperatureAlarmDuration, sleTemperatureControlDuration, sleSlotPowerMonIndex, sleEthernetPortSlotIndex, sleEthernetPortSlotPortIndex,
sleEthernetSfpVendorRevision, sleEthernetSfpVendorSerialNumber, sleEthernetSfpTransceiverCodes, sleSlotNosStbVersion, sleSlotNosStbRevision,
sleSlotNosStbSize, sleDeviceEnvironmentMonitoringStatus, sleDeviceControlEnvironmentMonitoringStatus, sleRfPowerStatus, sleSlotAiuRunStatus,
sleSlotAiuAlarmStatus, sleEthernetPortAdminTransmissionRate, sleEthernetPortAdminDuplexMode, sleEthernetPortAdminFlowControl, sleEthernetPortAdminNegotiationMode,
sleSlotReleasedSIUNosVersion, sleSlotReleasedSIUNosRevision, sleSlotReleasedSIUNosSize, sleEMInputIndex, sleEMAlarmString,
sleEMAlarmSeverity, sleEMmode, sleEMControlRequest, sleEMControlStatus, sleEMControlInputIndex,
sleEMControlAlarmString, sleEMControlAlarmSeverity, sleEMControlmode, sleEthernetSfpSpeed, sleEthernetSfpLength,
sleEthernetSfpWaveLength, sleRfEthertype, sleRfSrcAddress, sleRfDesAddress, sleRBUTempLowThreshold,
sleEthernetPortControlNegotiationMode, sleSlotStatusPower, sleSlotStatusSerialNumber, sleEMControlTimer, sleEMControlTimeStamp,
sleEthernetPortAdminReason, sleEMControlReqResult, sleRfBaseControlRequest, sleRfBaseControlStatus, sleRfBaseControlTimer,
sleRfBaseControlTimeStamp, sleRfBaseControlReqResult, sleRfBaseControlRfEthertype, sleRfPortControlRequest, sleRfPortControlStatus,
sleRfPortControlTimer, sleRfPortControlTimeStamp, sleRfPortControlReqResult, sleRfPortControlIndex, sleBypassMode,
sleBypassStatus, sleBypassBaseControlRequest, sleBypassBaseControlStatus, sleBypassBaseControlTimer, sleBypassBaseControlTimeStamp,
sleBypassBaseControlReqResult, sleBypassBaseControlMode, sleBypassOptionConnectivityAddress, sleBypassOptionConnectivityPort, sleBypassOptionConnectivityControlRequest,
sleBypassOptionConnectivityControlStatus, sleBypassOptionConnectivityControlTimer, sleBypassOptionConnectivityControlTimeStamp, sleBypassOptionConnectivityControlReqResult, sleBypassOptionConnectivityControlAddress,
sleBypassOptionConnectivityControlPort, sleBypassOptionPingAddress, sleBypassOptionPingTransInterval, sleBypassOptionPingTranNumber, sleBypassOptionPingReqInterval,
sleBypassOptionPingReqTimeout, sleBypassOptionPingLossThresh, sleBypassOptionPingControlRequest, sleBypassOptionPingControlStatus, sleBypassOptionPingControlTimer,
sleBypassOptionPingControlTimeStamp, sleBypassOptionPingControlReqResult, sleBypassOptionPingControlAddress, sleBypassOptionPingControlTransInterval, sleBypassOptionPingControlTranNumber,
sleBypassOptionPingControlReqInterval, sleBypassOptionPingControlReqTimeout, sleBypassOptionPingControlLossThresh, sleBypassOptionLinkMonitorPort, sleBypassOptionLinkMonitorPortStatus,
sleBypassOptionLinkMonitorControlRequest, sleBypassOptionLinkMonitorControlStatus, sleBypassOptionLinkMonitorControlTimer, sleBypassOptionLinkMonitorControlTimeStamp, sleBypassOptionLinkMonitorControlReqResult,
sleBypassOptionLinkMonitorControlPort, sleBypassOptionLinkMonitorControlPortStatus, sleSlotSystemInfoManufacturer, sleSlotSystemInfoManufactureDate, sleSlotStatusHealthState,
sleRfPortControlAdminStatus, sleClockInfoInSrcStatus, sleEthernetSfpMultimodeLengthOm1, sleEthernetSfpMultimodeLengthOm2, sleEthernetSfpTransceiverDetailTypeStr,
sleEthernetSfpTransceiverLengthStr, sleEthernetSfpWaveLengthStr, sleEthernetSfpConnectorType, sleSlotReleasedIU10GE8NosVersion, sleSlotReleasedIU10GE8NosRevision,
sleSlotReleasedIU10GE8NosSize, sleSlotReleasedIU10GEPON8NosVersion, sleSlotReleasedIU10GEPON8NosRevision, sleSlotReleasedIU10GEPON8NosSize, sleSlotReleasedIUGEPON8NosVersion,
sleSlotReleasedIUGEPON8NosRevision, sleSlotReleasedIUGEPON8NosSize, sleEthernetSfpMultimodeLengthOm3, sleSlotProtectionSystemStatus, sleSlotProtectionSystemThreshold,
sleSlotProtectionControlRequest, sleSlotProtectionControlStatus, sleSlotProtectionControlTimer, sleSlotProtectionControlTimeStamp, sleSlotProtectionControlReqResult,
sleSlotProtectionControlSystemStatus, sleSlotProtectionControlSystemThreshold, sleSlotProtectionIUControlRequest, sleSlotProtectionIUControlStatus, sleSlotProtectionIUControlTimer,
sleSlotProtectionIUControlTimeStamp, sleSlotProtectionIUControlReqResult, sleSlotProtectionIUControlTemperHighThresh, sleSlotProtectionIUControlTemperLowThresh, sleSlotProtectionIUControlPowerThresh,
sleSlotProtectionIUTemperHighThresh, sleSlotProtectionIUTemperLowThresh, sleSlotProtectionIUPowerStatus, sleSlotProtectionIUPowerThresh, sleSlotProtectionIUTemper,
sleHFCOptic1550OTX, sleHFCOptic1550OTXAlarm, sleHFCOpticUpstreamOTX, sleHFCOpticUpstreamOTXAlarm, sleHFCOpticDownstreamORX,
sleHFCOpticDownstreamORXAlarm, sleHFCEDFA1OTX, sleHFCEDFA1OTXAlarm, sleHFCEDFA1ORX, sleHFCEDFA1ORXAlarm,
sleHFCEDFA1LD1Current, sleHFCEDFA1LD1CurrentAlarm, sleHFCEDFA1LD2Current, sleHFCEDFA1LD2CurrentAlarm, sleHFCEDFA1LD1Temp,
sleHFCEDFA1LD1TempAlarm, sleHFCEDFA1LD2Temp, sleHFCEDFA1LD2TempAlarm, sleHFCEDFA1CaseTemp, sleHFCEDFA1CaseTempAlarm,
sleHFCEDFA2OTX, sleHFCEDFA2OTXAarm, sleHFCEDFA2ORX, sleHFCEDFA2ORXAlarm, sleHFCEDFA2LD1Current,
sleHFCEDFA2LD1CurrentAlarm, sleHFCEDFA2LD2Current, sleHFCEDFA2LD2CurrentAlarm, sleHFCEDFA2LD1Temp, sleHFCEDFA2LD1TempAlarm,
sleHFCEDFA2LD2Temp, sleHFCEDFA2LD2TempAlarm, sleHFCEDFA2CaseTemp, sleHFCEDFA2CaseTempAlarm, sleHFCControlRequest,
sleHFCControlStatus, sleHFCControlTimer, sleHFCControlTimeStamp, sleHFCControlReqResult, sleHFCControlAlarmIndex,
sleHFCControlAlarmStatus, sleSlotSystemCPULoadHighThreshold, sleSlotSystemCPULoadHighThresholdTimer, sleSlotSystemCPULoadLowThreshold, sleSlotSystemCPULoadLowThresholdTimer,
sleSlotProtectionIUControlindex, sleSlotSystemCPULoadCurrent, sleEthernetPortLinkCheckTimer, sleEthernetPortLinkDebounceTime, sleEthernetPortCpuStatisticsLimitUnicast,
sleEthernetPortCpuStatisticsLimitMulticast, sleEthernetPortCpuStatisticsLimitBroadcast, sleEthernetPortFloodBlockBroadcastState, sleEthernetPortFloodBlockDlfState, sleEthernetPortControlLinkCheckTimer,
sleEthernetPortControlLinkDebounceTime, sleEthernetPortControlCpuStatisticsLimitUnicast, sleEthernetPortControlCpuStatisticsLimitMulticast, sleEthernetPortControlCpuStatisticsLimitBroadcast, sleEthernetPortControlFloodBlockBroadcastState,
sleEthernetPortControlFloodBlockDlfState, sleEthernetSfpDdmState, sleEthernetSfpNegoState, sleEthernetSfpControlDdmState, sleEthernetSFPThresholdIfIndex,
sleEthernetSFPThresholdType, sleEthernetSFPThresholdSfpLow, sleEthernetSFPThresholdSfpHigh, sleEthernetSFPThresholdSystemLow, sleEthernetSFPThresholdSystemHigh,
sleEthernetSFPThresholdControlRequest, sleEthernetSFPThresholdControlStatus, sleEthernetSFPThresholdControlTimer, sleEthernetSFPThresholdControlTimeStamp, sleEthernetSFPThresholdControlReqResult,
sleEthernetSFPThresholdControlIfIndex, sleEthernetSFPThresholdControlType, sleEthernetSFPThresholdControlSfpLow, sleEthernetSFPThresholdControlSfpHigh, sleEthernetSFPThresholdControlSystemLow,
sleEthernetSFPThresholdControlSystemHigh, sleSlotSystemCPUOverallStatus, sleSlotSystemTemperOverallStatus, sleslotStatusOverallState, sleslotStatusSyncState,
sleSlotProtectionIUTemper2, sleSlotProtectionControlIUPowerStatus, sleSlotSystemControlCPULoadHighThreshold, sleSlotSystemControlCPULoadHighThresholdTimer, sleSlotSystemControlCPULoadLowThreshold,
sleSlotSystemControlCPULoadLowThresholdTimer }
STATUS current
DESCRIPTION
"Description."
::= { sleDevice 16 }
sleDeviceNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { sleDeviceTemperatureThresholdChanged, sleEthernetPortChanged, sleFanAdminStateChanged, sleBatteryBackupProfileChanged, sleBatteryBackupUpgraded,
sleSlotSystemRestart, sleSlotStatusLocked, sleSlotStatusUnlocked, sleSlotStatusPlanning, sleSlotStatusNoPlanning,
sleSlotStatusUpgradeModeChanged, sleSlotNosUpgrade, sleSlotStatusPowerUp, sleSlotStatusPowerDown, sleSlotStatusPowerReset,
sleSlotNosDownload, sleSlotNosBootloaderUpgrade, sleFanSpeedThresholdChanged, sleDeviceJumboFrameChanged, sleTemperatureThresholdChanged,
sleDeviceLEDTestChanged, sleEthernetSFPRemoteReset, sleRfPortStatusChanged, sleDeviceEnvironmentMonitoringStatusChanged, sleEMChanged,
sleEMDeleted, sleRFBaseEthertypeChanged, sleRFBaseEthertypeResetChanged, sleBypassModeChanged, sleBypassOptionConnectivitySet,
sleBypassOptionConnectivityUnset, sleBypassOptionPingSet, sleBypassOptionPingUnset, sleBypassOptionLinkMonitorChanged, sleSlotProtectionSystemStatusChanged,
sleSlotProtectionSystemThreshChanged, sleSlotProtectionIUTemperThreshChanged, sleSlotProtectionIUPowerThreshChanged, sleSlotProtectionIUPowerStatusChanged, sleHFCOpticAlarmStatusChanged,
sleSlotSystemCPULoadChagned, sleSlotSystemCPULoadDeleted, sleEthernetPortLinkChanged, sleEthernetPortCpuStatisticsLimitChanged, sleEthernetPortFloodBlockStateChanged,
sleEthernetSFPDdmState, sleEthernetSFPThresholdSfpChanged, sleEthernetSFPThresholdSystemChanged, sleEthernetSFPThresholdDestroyed, sleBatteryBackupTableCleared,
sleBatteryForceChargeChanged, sleBatteryChargingStartChanged, sleBatteryForceChargeNonStopChanged, sleBatteryRBUBTStatusChanged, sleBatteryRBUBTThresholdChanged,
sleBatteryRBURechargeVoltageChanged, sleBatteryPsuAcTemperThreshChanged, sleBatteryRBUTemperThreshChanged }
STATUS current
DESCRIPTION
"Description."
::= { sleDevice 17 }
END
--
-- SLE-DEVICE-MIB.my
--