mibs/MIBS/dasan/SLE-MPLS-TP-BFD-MIB
2023-12-05 12:25:34 +01:00

440 lines
11 KiB
Plaintext

--
-- sle-mpls-tp-bfd-mib.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
-- Tuesday, January 12, 2016 at 17:14:36
--
SLE-MPLS-TP-BFD-MIB DEFINITIONS ::= BEGIN
IMPORTS
sleMgmt
FROM DASAN-SMI
IANAbfdDiagTC
FROM IANA-BFD-TC-STD-MIB
SleControlStatusType, SleControlRequestResultType
FROM SLE-TC-MIB
mib-2, TimeTicks, Unsigned32, Gauge32, OBJECT-TYPE,
MODULE-IDENTITY, OBJECT-IDENTITY
FROM SNMPv2-SMI;
sleMplsTpBfd MODULE-IDENTITY
LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
ORGANIZATION
"Dasan Networks"
CONTACT-INFO
"Gyerok Kwon
Dasan Networks
Email: grkwon@dasannetworks.com
Kantharaj B M
Dasan Networks
Email: kanth@dasannetworks.com
DongChel Shin (Chris)
Dasan Networks
Email: dchshin@dasannetworks.com
Comments about this document should be emailed
directly to the Dasan support email ID at
support@dasannetworks.com."
DESCRIPTION
"Bidirectional Forwarding Management Information Base."
REVISION "200406030000Z" -- June 03, 2004 at 00:00 GMT
DESCRIPTION
"Initial version issued as part of RFC 3812."
::= { sleMpls 19 }
--
-- Node definitions
--
sleMpls OBJECT-IDENTITY
STATUS current
DESCRIPTION
"SLE MPLS."
::= { sleMgmt 16 }
sleMplsTpBfdCfg OBJECT IDENTIFIER ::= { sleMplsTpBfd 1 }
sleMplsTpBfdCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleBfdCfgInfoEntry
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The BFD Cfg Table describes the configuration details."
::= { sleMplsTpBfdCfg 1 }
sleMplsTpBfdCfgInfoEntry OBJECT-TYPE
SYNTAX SleBfdCfgInfoEntry
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The BFD Session Entry describes BFD session."
INDEX { sleMplsTpBfdCfgInfoMegIndex, sleMplsTpBfdCfgInfoMeIndex }
::= { sleMplsTpBfdCfgInfoTable 1 }
SleBfdCfgInfoEntry ::=
SEQUENCE {
sleMplsTpBfdCfgInfoMegIndex
Unsigned32,
sleMplsTpBfdCfgInfoMeIndex
Unsigned32,
sleMplsTpBfdCfgInfoMegName
OCTET STRING,
sleMplsTpBfdCfgInfoMeName
OCTET STRING,
sleMplsTpBfdCfgInfoTxInterval
OCTET STRING,
sleMplsTpBfdCfgInfoRXInterval
OCTET STRING
}
sleMplsTpBfdCfgInfoMegIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MEG Index."
::= { sleMplsTpBfdCfgInfoEntry 1 }
sleMplsTpBfdCfgInfoMeIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Maintenance Entity Index."
::= { sleMplsTpBfdCfgInfoEntry 2 }
sleMplsTpBfdCfgInfoMegName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MEG Index."
::= { sleMplsTpBfdCfgInfoEntry 3 }
sleMplsTpBfdCfgInfoMeName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maintenance Entity Index."
::= { sleMplsTpBfdCfgInfoEntry 4 }
sleMplsTpBfdCfgInfoTxInterval OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TX Packet Interval of BFD to neighbor."
::= { sleMplsTpBfdCfgInfoEntry 5 }
sleMplsTpBfdCfgInfoRXInterval OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RX Packet Interval of BFD from neighbor."
::= { sleMplsTpBfdCfgInfoEntry 6 }
sleMplsTpBfdCfgControl OBJECT IDENTIFIER ::= { sleMplsTpBfdCfg 2 }
sleMplsTpBfdCfgControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createBfdcfgEntry(1),
deleteBfdCfgEntry(2),
setIntervals(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object holds the possible read-write columns that can be
modified in the BFD Config table. For each read-write column of
BFD config table, a Set Operation control value is added in this
object."
::= { sleMplsTpBfdCfgControl 1 }
sleMplsTpBfdCfgControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object displays the status of the configuration done."
::= { sleMplsTpBfdCfgControl 2 }
sleMplsTpBfdCfgControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is based on the SLE style where a timer is
configured for every control table."
::= { sleMplsTpBfdCfgControl 3 }
sleMplsTpBfdCfgControlTimestamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the time at which the configuration is done."
::= { sleMplsTpBfdCfgControl 4 }
sleMplsTpBfdCfgControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The standard result of the SET operation is stored here."
::= { sleMplsTpBfdCfgControl 5 }
sleMplsTpBfdCfgControlMegName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MEG Name."
::= { sleMplsTpBfdCfgControl 6 }
sleMplsTpBfdCfgControlMeName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maintenance Entity Name."
::= { sleMplsTpBfdCfgControl 7 }
sleMplsTpBfdCfgControlTxInterval OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TX Packet Interval of BFD to neighbor."
::= { sleMplsTpBfdCfgControl 8 }
sleMplsTpBfdCfgControlRXInterval OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RX Packet Interval of BFD from neighbor."
::= { sleMplsTpBfdCfgControl 9 }
sleMplsTpBfdSession OBJECT IDENTIFIER ::= { sleMplsTpBfd 2 }
sleMplsTpBfdSessionInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleBfdSessionInfoEntry
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The BFD Session Table describes the BFD sessions."
REFERENCE
"Katz, D. and D. Ward, Bidirectional Forwarding
Detection (BFD), RFC 5880, June 2012."
::= { sleMplsTpBfdSession 1 }
sleMplsTpBfdSessionInfoEntry OBJECT-TYPE
SYNTAX SleBfdSessionInfoEntry
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The BFD Session Entry describes BFD session."
INDEX { sleMplsTpBfdSessionInfoSessIndex }
::= { sleMplsTpBfdSessionInfoTable 1 }
SleBfdSessionInfoEntry ::=
SEQUENCE {
sleMplsTpBfdSessionInfoSessIndex
Unsigned32,
sleMplsTpBfdSessionInfoMegName
OCTET STRING,
sleMplsTpBfdSessionInfoMeName
OCTET STRING,
sleMplsTpBfdSessionInfoVersionNumber
Unsigned32,
sleMplsTpBfdSessionInfoDiscriminator
Unsigned32,
sleMplsTpBfdSessionInfoRemoteDiscriminator
Unsigned32,
sleMplsTpBfdSessionInfoState
INTEGER,
sleMplsTpBfdSessionInfoDiag
IANAbfdDiagTC,
sleMplsTpBfdSessionInfoDesiredMinTxInterval
OCTET STRING,
sleMplsTpBfdSessionInfoReqMinRxInterval
OCTET STRING,
sleMplsTpBfdSessionInfoDetectMult
Unsigned32
}
sleMplsTpBfdSessionInfoSessIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object contains an index used to represent a
unique BFD session on this device."
::= { sleMplsTpBfdSessionInfoEntry 1 }
sleMplsTpBfdSessionInfoMegName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MEG Name of the BFD Session."
::= { sleMplsTpBfdSessionInfoEntry 2 }
sleMplsTpBfdSessionInfoMeName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MEG Name of the BFD Session."
::= { sleMplsTpBfdSessionInfoEntry 3 }
sleMplsTpBfdSessionInfoVersionNumber OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version number of the BFD protocol that this session
is running in. Write access is available for this object
to provide ability to set desired version for this
BFD session."
REFERENCE
"Katz, D. and D. Ward, Bidirectional Forwarding
Detection (BFD), RFC 5880, June 2012."
DEFVAL { 1 }
::= { sleMplsTpBfdSessionInfoEntry 4 }
sleMplsTpBfdSessionInfoDiscriminator OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the local discriminator for this BFD
session, used to uniquely identify it."
::= { sleMplsTpBfdSessionInfoEntry 5 }
sleMplsTpBfdSessionInfoRemoteDiscriminator OBJECT-TYPE
SYNTAX Unsigned32 (0 | 1..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the session discriminator chosen
by the remote system for this BFD session. The value may
be zero(0) if the remote discriminator is not yet known
or if the session is in the down or adminDown(1) state."
REFERENCE
"Section 6.8.6, from Katz, D. and D. Ward, Bidirectional
Forwarding Detection (BFD), RFC 5880, June 2012."
::= { sleMplsTpBfdSessionInfoEntry 6 }
sleMplsTpBfdSessionInfoState OBJECT-TYPE
SYNTAX INTEGER
{
adminDown(0),
stateDown(1),
stateInit(2),
stateUp(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BFD session state."
::= { sleMplsTpBfdSessionInfoEntry 7 }
sleMplsTpBfdSessionInfoDiag OBJECT-TYPE
SYNTAX IANAbfdDiagTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A diagnostic code specifying the local system's reason
for the last transition of the session from up(4)
to some other state."
::= { sleMplsTpBfdSessionInfoEntry 8 }
sleMplsTpBfdSessionInfoDesiredMinTxInterval OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum interval, in
microseconds, that the local system would like to use
when transmitting BFD Control packets. The value of
zero(0) is reserved, and should not be used."
REFERENCE
"Section 4.1 from Katz, D. and D. Ward, Bidirectional
Forwarding Detection (BFD), RFC 5880, June 2012."
::= { sleMplsTpBfdSessionInfoEntry 9 }
sleMplsTpBfdSessionInfoReqMinRxInterval OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum interval, in
microseconds, between received BFD Control packets the
local system is capable of supporting. The value of
zero(0) can be specified when the transmitting system
does not want the remote system to send any periodic BFD
control packets."
REFERENCE
"Section 4.1 from Katz, D. and D. Ward, Bidirectional
Forwarding Detection (BFD), RFC 5880, June 2012."
::= { sleMplsTpBfdSessionInfoEntry 10 }
sleMplsTpBfdSessionInfoDetectMult OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION " "
::= { sleMplsTpBfdSessionInfoEntry 11 }
END
--