-- sle-mpls-tp-lps-mib.mib
|
|
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
|
|
-- Tuesday, January 12, 2016 at 11:21:30
|
|
--
|
|
|
|
SLE-MPLS-TP-LPS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
sleMgmt
|
|
FROM DASAN-SMI
|
|
SleControlStatusType, SleControlRequestResultType
|
|
FROM SLE-TC-MIB
|
|
TimeTicks, Unsigned32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY,
|
|
OBJECT-IDENTITY
|
|
FROM SNMPv2-SMI;
|
|
|
|
|
|
sleMplsTpLps MODULE-IDENTITY
|
|
LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
|
|
ORGANIZATION
|
|
"Multiprotocol Label Switching (MplsTp) Working Group"
|
|
CONTACT-INFO
|
|
"Gyerok Kwon
|
|
Dasan Networks
|
|
Email: grkwon@dasannetworks.com
|
|
|
|
Kantharaj B M
|
|
Dasan Networks
|
|
Email: kanth@dasannetworks.com
|
|
|
|
DongChel Shin (Chris)
|
|
Dasan Networks
|
|
Email: dchshin@dasannetworks.com
|
|
|
|
Comments about this document should be emailed
|
|
directly to the Dasan support email ID at
|
|
support@dasannetworks.com."
|
|
DESCRIPTION
|
|
"This management information module supports the
|
|
configuration and management of MplsTp TP linear
|
|
protection groups. "
|
|
REVISION "201207150000Z" -- July 15, 2012 at 00:00 GMT
|
|
DESCRIPTION
|
|
"MplsTp Protection Switching Group objects for LSP MEPs"
|
|
::= { sleMpls 18 }
|
|
|
|
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
sleMpls OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SLE MplsTp."
|
|
::= { sleMgmt 16 }
|
|
|
|
|
|
sleMplsTpLpsCfg OBJECT IDENTIFIER ::= { sleMplsTpLps 1 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SleMplsTpLpsCfgInfoEntry
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table lists the sleMplsTp linear protection groups that
|
|
have been configured on the system."
|
|
::= { sleMplsTpLpsCfg 1 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoEntry OBJECT-TYPE
|
|
SYNTAX SleMplsTpLpsCfgInfoEntry
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row in the sleMplsTpLpsCfgInfoTable."
|
|
INDEX { sleMplsTpLpsCfgInfoGroupIndex }
|
|
::= { sleMplsTpLpsCfgInfoTable 1 }
|
|
|
|
|
|
SleMplsTpLpsCfgInfoEntry ::=
|
|
SEQUENCE {
|
|
sleMplsTpLpsCfgInfoGroupIndex
|
|
Unsigned32,
|
|
sleMplsTpLpsCfgInfoGroupName
|
|
OCTET STRING,
|
|
sleMplsTpLpsCfgInfoMode
|
|
INTEGER,
|
|
sleMplsTpLpsCfgInfoProtectionScheme
|
|
INTEGER,
|
|
sleMplsTpLpsCfgInfoRevertive
|
|
INTEGER,
|
|
sleMplsTpLpsCfgInfoWtr
|
|
Unsigned32,
|
|
sleMplsTpLpsCfgInfoContinualTxInterval
|
|
Unsigned32,
|
|
sleMplsTpLpsCfgInfoRapidTxInterval
|
|
Unsigned32,
|
|
sleMplsTpLpsCfgInfoSwitchOver
|
|
INTEGER,
|
|
sleMplsTpLpsCfgInfoLockOut
|
|
INTEGER,
|
|
sleMplsTpLpsCfgInfoHoldOffTimer
|
|
Unsigned32,
|
|
sleMplsTpLpsCfgInfoActivePath
|
|
INTEGER,
|
|
sleMplsTpLpsCfgInfoOperationState
|
|
INTEGER,
|
|
sleMplsTpLpsCfgInfoEventStatus
|
|
INTEGER
|
|
}
|
|
|
|
sleMplsTpLpsCfgInfoGroupIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for the conceptual row identifying a protection group."
|
|
::= { sleMplsTpLpsCfgInfoEntry 1 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoGroupName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual name represents the sleMplsTp tp protection group.
|
|
Each Protection Group is identified by a unique
|
|
protection group name. "
|
|
::= { sleMplsTpLpsCfgInfoEntry 2 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
onePlusOne(1),
|
|
oneColonOne(2),
|
|
oneColonN(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The architectural mode of the Protection group. This can
|
|
either be 1+1, 1:1, 1:n.
|
|
|
|
1+1
|
|
|
|
In the 1+1 protection scheme, a fully dedicated
|
|
protection entity is allocated. Data traffic is copied
|
|
and fed at the source to both the working and the
|
|
protection entities. The traffic on the working and the
|
|
protection entities is transmitted simultaneously to
|
|
the sink of the protection domain, where selection
|
|
between the working and protection entities is performed
|
|
|
|
1:1
|
|
|
|
In the 1:1 scheme, a protection path is allocated to
|
|
protect against a defect, failure, or a degradation in a
|
|
working path. In normal conditions, data traffic is
|
|
transmitted over the working entity, while the
|
|
protection entity functions in the idle state. If there
|
|
is a defect on the working entity or a specific
|
|
administrative request, traffic is switched to the
|
|
protection entity.
|
|
|
|
1:n
|
|
|
|
In case of 1:n linear protection, one protection entity
|
|
is allocated to protect n working entities. The protection
|
|
entity might not have sufficient resources to protect all the
|
|
working entities that may be affected by fault conditions at a
|
|
specific time. In this case, in order to guaranteed
|
|
protection, the protection entity should support enough
|
|
capacity and bandwidth to protect any of the n working
|
|
entities."
|
|
DEFVAL { oneColonOne }
|
|
::= { sleMplsTpLpsCfgInfoEntry 3 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoProtectionScheme OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
bidirectional(1),
|
|
unidirectional(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object represents the operational scheme of
|
|
protection switching group. The protection scheme may
|
|
either be unidirectional or bidirectional.
|
|
|
|
bidirectional
|
|
In bidirectional protection scheme, both the directions
|
|
will be switched simultaneously even if the fault
|
|
applies to only one direction of the path.
|
|
|
|
unidirectional
|
|
In unidirectional protection scheme protection switching
|
|
will be performed independently for each direction of a
|
|
bidirectional transport path
|
|
|
|
This object may not be modified if the associated
|
|
sleMplsTpLpsCfgRowStatus object is equal to active(1). "
|
|
DEFVAL { bidirectional }
|
|
::= { sleMplsTpLpsCfgInfoEntry 4 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoRevertive OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
nonrevertive(1),
|
|
revertive(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the reversion mode of the Linear
|
|
Protection Switching group. The reversion mode of
|
|
protection mechanism may be either revertive or
|
|
non-revertive.
|
|
|
|
In non-revertive mode, after a service has been
|
|
recovered, traffic will be forwarded on the recovery
|
|
path revertive
|
|
In revertive mode, after a service has been
|
|
recovered, traffic will be redirected back onto the
|
|
original working path."
|
|
DEFVAL { nonrevertive }
|
|
::= { sleMplsTpLpsCfgInfoEntry 5 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoWtr OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..720)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object hold the Wait To Restore timer value in
|
|
seconds.
|
|
The WTR timer is used to delay reversion of PSC state
|
|
to Normal state when recovering from a failure
|
|
condition on the working path when the protection
|
|
domain is configured for revertive behavior
|
|
|
|
This object may not be modified if the associated
|
|
sleMplsTpLpsCfgRowStatus object is equal to active(1)."
|
|
DEFVAL { 300 }
|
|
::= { sleMplsTpLpsCfgInfoEntry 6 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoContinualTxInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..20)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Continual Tx Time in Seconds. Represents the time
|
|
interval to send the continual LPS packet to the other
|
|
end based on the current state."
|
|
DEFVAL { 5 }
|
|
::= { sleMplsTpLpsCfgInfoEntry 7 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoRapidTxInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1000..20000)
|
|
UNITS "micro-seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Rapid Tx interval in micro-Seconds. Represents the time
|
|
interval to send the LPS packet to the other end, when
|
|
there is a change in state of Linear Protection domain due
|
|
to local input. The default value is 3.3 milli-seconds
|
|
which is 3300 micro-seconds"
|
|
DEFVAL { 3300 }
|
|
::= { sleMplsTpLpsCfgInfoEntry 8 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoSwitchOver OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none(0),
|
|
forced(1),
|
|
manual(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" this object used for switch the traffic to the back up path."
|
|
::= { sleMplsTpLpsCfgInfoEntry 9 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoLockOut OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"this is object is used for preventing the swith traffic by the protection path."
|
|
::= { sleMplsTpLpsCfgInfoEntry 10 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoHoldOffTimer OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" this object used for show the hold off timer."
|
|
::= { sleMplsTpLpsCfgInfoEntry 11 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoActivePath OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
primary(1),
|
|
backup(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object say which path is Active ."
|
|
::= { sleMplsTpLpsCfgInfoEntry 12 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoOperationState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(0)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"this object says Operational Status of LPS. The LPS is between PE to PE."
|
|
DEFVAL { 0 }
|
|
::= { sleMplsTpLpsCfgInfoEntry 13 }
|
|
|
|
|
|
sleMplsTpLpsCfgInfoEventStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(1),
|
|
protection(2),
|
|
localForce(3),
|
|
localManual(4),
|
|
localSgfProtection(5),
|
|
localSgfWorking(6),
|
|
localWtr(7),
|
|
localLock(8),
|
|
localClrSfProtection(9),
|
|
localClrSfWorking(10),
|
|
localClrEvent(11),
|
|
remoteLock(12),
|
|
remoteForce(13),
|
|
remoteManual(14),
|
|
remoteSfProtect(15),
|
|
remoteSfWork(16),
|
|
remoteWtr(17),
|
|
remoteNoReq(18),
|
|
remoteNotRevert(19),
|
|
noRequest(20),
|
|
remoteSdWork(21),
|
|
remoteSdProtection(22),
|
|
remoteExesWork(23),
|
|
remoteExesProtect(24),
|
|
remoteRrReqWork(25),
|
|
remoteRrReqProtec(26),
|
|
remoteNoReqWork(27),
|
|
remoteNoReqProtection(28),
|
|
localSdProtection(29),
|
|
localClearSdProtection(30),
|
|
localSdWorking(31),
|
|
localClearSdWorking(32),
|
|
localExercise(33)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is object says EVENT Status of LPS protection ."
|
|
DEFVAL { 0 }
|
|
::= { sleMplsTpLpsCfgInfoEntry 14 }
|
|
|
|
|
|
sleMplsTpLpsCfgControl OBJECT IDENTIFIER ::= { sleMplsTpLpsCfg 2 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlRequest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
createSleMplsTpLpsCfgEntry(1),
|
|
deleteSleMplsTpLpsCfgEntry(2),
|
|
setSleMplsTpLpsCfgControProtectionScheme(3),
|
|
unsetSleMplsTpLpsCfgControProtectionScheme(4),
|
|
setSleMplsLpsTpCfgControlRevertive(5),
|
|
setSleMplsLpsTpCfgControlWaitToRestoreset(6),
|
|
unsetSleMplsTpLpsCfgControlWaitToRestoreset(7),
|
|
setSleMplsLpsTpCfgControlContinualTxInterval(8),
|
|
unsetSleMplsTpLpsCfgControlContinualTxInterval(9),
|
|
setSleMplsLpsTpCfgControlRapidTxInterval(10),
|
|
unsetSleMplsTpLpsCfgControlRapidTxInterval(11),
|
|
setSleMplsLpsTpCfgControlSwitchover(12),
|
|
unsetSleMplsTpLpsCfgControlSwitchover(13),
|
|
setSleMplsTpLpsCfgControlLockOut(14),
|
|
unsetSleMplsTpLpsTpCfgControlLockOut(15),
|
|
setSleMplsTpLpsCfgControlHoldOffTimer(16),
|
|
unSetSleMplsTpLpsCfgControlHoldOffTimer(17)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the configuration commands, and user can configure functions
|
|
via setting this entry as proper value."
|
|
::= { sleMplsTpLpsCfgControl 1 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlStatus OBJECT-TYPE
|
|
SYNTAX SleControlStatusType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"status of user command. User have to check this value as
|
|
.busy. or .idle. before do setRequest."
|
|
::= { sleMplsTpLpsCfgControl 2 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlTimer OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the wait-time until setRequest end. In case of short-time command, this value is 0"
|
|
::= { sleMplsTpLpsCfgControl 3 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the time stamp of the last command. (don.t care)"
|
|
::= { sleMplsTpLpsCfgControl 4 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlReqResult OBJECT-TYPE
|
|
SYNTAX SleControlRequestResultType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Result of the last command."
|
|
::= { sleMplsTpLpsCfgControl 5 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlGroupName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual name represents the sleMplsTp tp protection group.
|
|
Each Protection Group is identified by a unique
|
|
protection group name. "
|
|
::= { sleMplsTpLpsCfgControl 6 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
onePlusOne(1),
|
|
oneColonOne(2),
|
|
oneColonN(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The architectural mode of the Protection group. This can
|
|
either be 1+1, 1:1, 1:n.
|
|
|
|
1+1
|
|
|
|
In the 1+1 protection scheme, a fully dedicated
|
|
protection entity is allocated. Data traffic is copied
|
|
|
|
|
|
|
|
and fed at the source to both the working and the
|
|
protection entities. The traffic on the working and the
|
|
protection entities is transmitted simultaneously to
|
|
the sink of the protection domain, where selection
|
|
between the working and protection entities is performed
|
|
|
|
1:1
|
|
|
|
In the 1:1 scheme, a protection path is allocated to
|
|
protect against a defect, failure, or a degradation in a
|
|
working path. In normal conditions, data traffic is
|
|
transmitted over the working entity, while the
|
|
protection entity functions in the idle state. If there
|
|
is a defect on the working entity or a specific
|
|
administrative request, traffic is switched to the
|
|
protection entity.
|
|
|
|
1:n
|
|
|
|
In case of 1:n linear protection, one protection entity
|
|
is allocated to protect n working entities. The protection
|
|
entity might not have sufficient resources to protect all the
|
|
working entities that may be affected by fault conditions at a
|
|
specific time. In this case, in order to guaranteed
|
|
protection, the protection entity should support enough
|
|
capacity and bandwidth to protect any of the n working
|
|
entities."
|
|
DEFVAL { oneColonOne }
|
|
::= { sleMplsTpLpsCfgControl 7 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlProtectionScheme OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
bidirectional(1),
|
|
unidirectional(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object represents the operational scheme of
|
|
protection switching group. The protection scheme may
|
|
either be unidirectional or bidirectional.
|
|
|
|
bidirectional
|
|
In bidirectional protection scheme, both the directions
|
|
will be switched simultaneously even if the fault
|
|
applies to only one direction of the path.
|
|
|
|
unidirectional
|
|
In unidirectional protection scheme protection switching
|
|
will be performed independently for each direction of a
|
|
bidirectional transport path
|
|
|
|
This object may not be modified if the associated
|
|
sleMplsTpLpsCfgControlRowStatus object is equal to active(1). "
|
|
DEFVAL { bidirectional }
|
|
::= { sleMplsTpLpsCfgControl 8 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlRevertive OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
nonrevertive(1),
|
|
revertive(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the reversion mode of the Linear
|
|
Protection Switching group. The reversion mode of
|
|
protection mechanism may be either revertive or
|
|
non-revertive.
|
|
|
|
nonrevertive
|
|
In non-revertive mode, after a service has been
|
|
recovered, traffic will be forwarded on the recovery
|
|
path
|
|
|
|
revertive
|
|
In revertive mode, after a service has been
|
|
recovered, traffic will be redirected back onto the
|
|
original working path."
|
|
DEFVAL { nonrevertive }
|
|
::= { sleMplsTpLpsCfgControl 9 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlWtr OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..720)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object hold the Wait To Restore timer value in
|
|
seconds.
|
|
The WTR timer is used to delay reversion of PSC state
|
|
to Normal state when recovering from a failure
|
|
condition on the working path when the protection
|
|
domain is configured for revertive behavior
|
|
|
|
This object may not be modified if the associated
|
|
sleMplsTpLpsCfgControlRowStatus object is equal to active(1)."
|
|
DEFVAL { 300 }
|
|
::= { sleMplsTpLpsCfgControl 10 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlContinualTxInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..20)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Continual Tx Time in Seconds. Represents the time
|
|
interval to send the continual LPS packet to the other
|
|
end based on the current state."
|
|
DEFVAL { 5 }
|
|
::= { sleMplsTpLpsCfgControl 11 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlRapidTxInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1000)
|
|
UNITS "micro-seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Rapid Tx interval in micro-Seconds. Represents the time
|
|
interval to send the LPS packet to the other end, when
|
|
there is a change in state of Linear Protection domain due
|
|
to local input. The default value is 3.3 milli-seconds
|
|
which is 3300 micro-seconds"
|
|
DEFVAL { 3300 }
|
|
::= { sleMplsTpLpsCfgControl 12 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlswitchOver OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
force(1),
|
|
manual(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" this object used for switch the traffic to the back up path."
|
|
::= { sleMplsTpLpsCfgControl 13 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlLockOut OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enable(1),
|
|
disable(0)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"this is object is used for preventing the swith traffic by the protection path."
|
|
::= { sleMplsTpLpsCfgControl 14 }
|
|
|
|
|
|
sleMplsTpLpsCfgControlHoldOffTimer OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set the holdofftimer "
|
|
::= { sleMplsTpLpsCfgControl 15 }
|
|
|
|
|
|
sleMplsTpLpsMeCfg OBJECT IDENTIFIER ::= { sleMplsTpLps 2 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SleMplsTpLpsMeCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table lists Maintenance Association that have been
|
|
configured in Protection groups."
|
|
::= { sleMplsTpLpsMeCfg 1 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgInfoEntry OBJECT-TYPE
|
|
SYNTAX SleMplsTpLpsMeCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row in the sleMplsTpLpsMeCfgInfoTable."
|
|
INDEX { sleMplsTpLpsMeCfgInfoMeIndex, sleMplsTpLpsMeCfgInfoMPId, sleMplsTpLspMeCfgInfoGroupIndex, sleMplsTpLpsMeCfgInfoMegIndex }
|
|
::= { sleMplsTpLpsMeCfgInfoTable 1 }
|
|
|
|
|
|
SleMplsTpLpsMeCfgInfoEntry ::=
|
|
SEQUENCE {
|
|
sleMplsTpLpsMeCfgInfoMegIndex
|
|
Unsigned32,
|
|
sleMplsTpLpsMeCfgInfoMeIndex
|
|
Unsigned32,
|
|
sleMplsTpLpsMeCfgInfoMPId
|
|
Unsigned32,
|
|
sleMplsTpLspMeCfgInfoGroupIndex
|
|
Unsigned32,
|
|
sleMplsTpLpsMeCfgInfoState
|
|
INTEGER
|
|
}
|
|
|
|
sleMplsTpLpsMeCfgInfoMegIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies a maintenance entity index within
|
|
a MEG."
|
|
::= { sleMplsTpLpsMeCfgInfoEntry 1 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgInfoMeIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object denotes the ME name, each
|
|
Maintenance Entity has unique name within MEG."
|
|
::= { sleMplsTpLpsMeCfgInfoEntry 2 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgInfoMPId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..8191)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maintenance point index, used to create
|
|
multiple MEPs in a node of single ME. The value of this
|
|
object can be MEP index or MIP index. Managers should
|
|
obtain new values for row creation in this table by reading
|
|
mplsOamIdMeMpIndexNext."
|
|
::= { sleMplsTpLpsMeCfgInfoEntry 3 }
|
|
|
|
|
|
sleMplsTpLspMeCfgInfoGroupIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual name represents the sleMplsTp tp protection group.
|
|
Each Protection Group is identified by a unique
|
|
protection group name. "
|
|
::= { sleMplsTpLpsMeCfgInfoEntry 4 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgInfoState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
primary(1),
|
|
backup(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the operational state of the ME
|
|
as either primary or backup"
|
|
::= { sleMplsTpLpsMeCfgInfoEntry 5 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgControl OBJECT IDENTIFIER ::= { sleMplsTpLpsMeCfg 2 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgControlRequest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
createSleMplsTpLpsMeConfigEntry(1),
|
|
deleteSleMplsTpLpsMeConfigEntry(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the configuration commands, and user can configure functions via setting
|
|
this entry as proper value."
|
|
::= { sleMplsTpLpsMeCfgControl 1 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgControlStatus OBJECT-TYPE
|
|
SYNTAX SleControlStatusType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"status of user command. User have to check this value as
|
|
.busy. or .idle. before do setRequest."
|
|
::= { sleMplsTpLpsMeCfgControl 2 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgControlTimer OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the wait-time until setRequest end. In case of short-time command, this value is 0"
|
|
::= { sleMplsTpLpsMeCfgControl 3 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgControlTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the time stamp of the last command. (don.t care)"
|
|
::= { sleMplsTpLpsMeCfgControl 4 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgControlReqResult OBJECT-TYPE
|
|
SYNTAX SleControlRequestResultType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Result of the last command."
|
|
::= { sleMplsTpLpsMeCfgControl 5 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgControlMegName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies a maintenance entity index within
|
|
a MEG"
|
|
::= { sleMplsTpLpsMeCfgControl 6 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgControlMeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object denotes the ME name, each
|
|
Maintenance Entity has unique name within MEG."
|
|
::= { sleMplsTpLpsMeCfgControl 7 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgControlMpId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
::= { sleMplsTpLpsMeCfgControl 8 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgControlGroupName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the Protection group index wherein
|
|
this ME included in. If this ME is not part of a protection
|
|
group this value is set to 0. "
|
|
::= { sleMplsTpLpsMeCfgControl 9 }
|
|
|
|
|
|
sleMplsTpLpsMeCfgControlState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
primary(1),
|
|
backup(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the operational state of the ME
|
|
as either primary or backup"
|
|
::= { sleMplsTpLpsMeCfgControl 10 }
|
|
|
|
|
|
|
|
END
|
|
|
|
--
|
|