-- sle-mpls-tp-node-mib.mib
|
|
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
|
|
-- Tuesday, January 12, 2016 at 11:22:02
|
|
--
|
|
|
|
SLE-MPLS-TP-NODE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
sleMgmt
|
|
FROM DASAN-SMI
|
|
MplsCcId, MplsIccId
|
|
FROM MPLS-TC-EXT-STD-MIB
|
|
mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId
|
|
FROM MPLS-TE-STD-MIB
|
|
SleControlStatusType, SleControlRequestResultType
|
|
FROM SLE-TC-MIB
|
|
zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32,
|
|
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
|
|
FROM SNMPv2-SMI;
|
|
|
|
|
|
sleMplsTpNode MODULE-IDENTITY
|
|
LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
|
|
ORGANIZATION
|
|
"Multiprotocol Label Switching (MPLS) Working Group"
|
|
CONTACT-INFO
|
|
"Gyerok Kwon
|
|
Dasan Networks
|
|
Email: grkwon@dasannetworks.com
|
|
|
|
Kantharaj B M
|
|
Dasan Networks
|
|
Email: kanth@dasannetworks.com
|
|
|
|
DongChel Shin (Chris)
|
|
Dasan Networks
|
|
Email: dchshin@dasannetworks.com
|
|
|
|
Comments about this document should be emailed
|
|
directly to the Dasan support email ID at
|
|
support@dasannetworks.com."
|
|
DESCRIPTION
|
|
"Copyright (c) 2012 IETF Trust and the persons identified
|
|
as the document authors. All rights reserved.
|
|
|
|
This MIB module contains generic object definitions for
|
|
MPLS Traffic Engineering in transport networks."
|
|
REVISION "201207150000Z" -- July 15, 2012 at 00:00 GMT
|
|
DESCRIPTION
|
|
"MPLS_TP node configuration table"
|
|
::= { sleMpls 13 }
|
|
|
|
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
sleMpls OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SLE MPLS."
|
|
::= { sleMgmt 16 }
|
|
|
|
|
|
sleMplsTpNodeCfg OBJECT IDENTIFIER ::= { sleMplsTpNode 1 }
|
|
|
|
|
|
sleMplsTpNodeCfgInfo OBJECT IDENTIFIER ::= { sleMplsTpNodeCfg 1 }
|
|
|
|
|
|
sleMplsTpNodeCfgInfoGlobalId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Global Operator Identifier.
|
|
this object value should be zero when
|
|
sleMplsTpNodeConfigInfoCcId and sleMplsTpNodeConfigInfoICcId
|
|
is configured with non-null value."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers [RFC6370]."
|
|
::= { sleMplsTpNodeCfgInfo 1 }
|
|
|
|
|
|
sleMplsTpNodeCfgInfoItutCc OBJECT-TYPE
|
|
SYNTAX MplsCcId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the operator or service provider to
|
|
configure a unique MPLS-TP ITU-T Carrier Code (ICC)
|
|
either for Ingress ID or Egress ID.
|
|
|
|
This object value should be zero when
|
|
sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers [RFC6370]."
|
|
::= { sleMplsTpNodeCfgInfo 2 }
|
|
|
|
|
|
sleMplsTpNodeCfgInfoItutIcc OBJECT-TYPE
|
|
SYNTAX MplsIccId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the operator or service provider to
|
|
configure a unique MPLS-TP ITU-T Carrier Code (ICC)
|
|
either for Ingress ID or Egress ID.
|
|
|
|
This object value should be zero when
|
|
sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers [RFC6370]."
|
|
::= { sleMplsTpNodeCfgInfo 3 }
|
|
|
|
|
|
sleMplsTpNodeCfgInfoNodeId OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Node_ID within the operator."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers [RFC6370]."
|
|
::= { sleMplsTpNodeCfgInfo 4 }
|
|
|
|
|
|
sleMplsTpNodeCfgInfoNodeType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ietf(1),
|
|
itut(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object value should be zero when
|
|
sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value ."
|
|
::= { sleMplsTpNodeCfgInfo 5 }
|
|
|
|
|
|
sleMplsTpNodeCfgControl OBJECT IDENTIFIER ::= { sleMplsTpNodeCfg 2 }
|
|
|
|
|
|
sleMplsTpNodeCfgControlRequest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
setMplsTpNode(1),
|
|
unsetMplsTpNode(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the possible read-write columns that can be
|
|
modified in the TunnelExtNodeConfigTable table. For each read-write
|
|
column of TunnelExtNodeConfigTable table, a Set Operation control
|
|
value is added in this object."
|
|
::= { sleMplsTpNodeCfgControl 1 }
|
|
|
|
|
|
sleMplsTpNodeCfgControlStatus OBJECT-TYPE
|
|
SYNTAX SleControlStatusType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the status of the configuration done."
|
|
::= { sleMplsTpNodeCfgControl 2 }
|
|
|
|
|
|
sleMplsTpNodeCfgControlTimer OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is based on the SLE style where a timer is configured
|
|
for every control table."
|
|
::= { sleMplsTpNodeCfgControl 3 }
|
|
|
|
|
|
sleMplsTpNodeCfgControlTimestamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the time at which the configuration is done."
|
|
::= { sleMplsTpNodeCfgControl 4 }
|
|
|
|
|
|
sleMplsTpNodeCfgControlReqResult OBJECT-TYPE
|
|
SYNTAX SleControlRequestResultType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The standard result of the SET operation is stored here."
|
|
::= { sleMplsTpNodeCfgControl 5 }
|
|
|
|
|
|
sleMplsTpNodeCfgControlGlobalId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Global Operator Identifier.
|
|
This object value should be zero when
|
|
sleMplsTpNodeConfigControlIccId and sleMplsTpNodeConfigControlccId
|
|
is configured with non-null value."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers [RFC6370]."
|
|
::= { sleMplsTpNodeCfgControl 6 }
|
|
|
|
|
|
sleMplsTpNodeCfgControlItutCc OBJECT-TYPE
|
|
SYNTAX MplsCcId
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the operator or service provider to
|
|
configure a unique MPLS-TP ITU-T Carrier Code (ICC)
|
|
either for Ingress ID or Egress ID.
|
|
|
|
This object value should be zero when
|
|
sleMplsTpNodeConfigControlGlobalId are assigned with
|
|
non-zero value."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers [RFC6370]."
|
|
::= { sleMplsTpNodeCfgControl 7 }
|
|
|
|
|
|
sleMplsTpNodeCfgControlItutIcc OBJECT-TYPE
|
|
SYNTAX MplsIccId
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the operator or service provider to configure a
|
|
unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID
|
|
or Egress ID.
|
|
|
|
This object value should be zero when
|
|
sleMplsTpNodeConfigControlGlobalId are assigned with non-zero
|
|
value."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers [RFC6370]."
|
|
::= { sleMplsTpNodeCfgControl 8 }
|
|
|
|
|
|
sleMplsTpNodeCfgControlNodeId OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Node_ID within the operator."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers [RFC6370]."
|
|
::= { sleMplsTpNodeCfgControl 9 }
|
|
|
|
|
|
sleMplsTpNodeCfgControlNodeType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ietf(1),
|
|
itut(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the operator or service provider to
|
|
configure a unique MPLS-TP ITU-T Carrier Code (ICC)
|
|
either for Ingress ID or Egress ID.
|
|
|
|
This object value should be zero when
|
|
msleMplsTpNodeConfigControlGlobalId are assigned with non-zero
|
|
value."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers [RFC6370]."
|
|
::= { sleMplsTpNodeCfgControl 10 }
|
|
|
|
|
|
|
|
END
|
|
|
|
--
|
|