-- sle-mpls-tp-pro-if-mib.mib
|
|
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
|
|
-- Tuesday, January 12, 2016 at 14:08:09
|
|
--
|
|
|
|
SLE-MPLS-TP-PRO-IF-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
sleMgmt
|
|
FROM DASAN-SMI
|
|
mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId
|
|
FROM MPLS-TE-STD-MIB
|
|
SleControlStatusType, SleControlRequestResultType
|
|
FROM SLE-TC-MIB
|
|
zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32,
|
|
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
|
|
FROM SNMPv2-SMI;
|
|
|
|
|
|
sleMplsTpNode MODULE-IDENTITY
|
|
LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
|
|
ORGANIZATION
|
|
"Multiprotocol Label Switching (MPLS) Working Group"
|
|
CONTACT-INFO
|
|
"Gyerok Kwon
|
|
Dasan Networks
|
|
Email: grkwon@dasannetworks.com
|
|
|
|
Kantharaj B M
|
|
Dasan Networks
|
|
Email: kanth@dasannetworks.com
|
|
|
|
DongChel Shin (Chris)
|
|
Dasan Networks
|
|
Email: dchshin@dasannetworks.com
|
|
|
|
Comments about this document should be emailed
|
|
directly to the Dasan support email ID at
|
|
support@dasannetworks.com."
|
|
DESCRIPTION
|
|
"Copyright (c) 2012 IETF Trust and the persons identified
|
|
as the document authors. All rights reserved.
|
|
|
|
This MIB module contains generic object definitions for
|
|
MPLS Traffic Engineering in transport networks."
|
|
REVISION "201207150000Z" -- July 15, 2012 at 00:00 GMT
|
|
DESCRIPTION
|
|
"MPLS_TP node configuration table"
|
|
::= { sleMpls 13 }
|
|
|
|
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
sleMpls OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SLE MPLS."
|
|
::= { sleMgmt 16 }
|
|
|
|
|
|
sleMplsTpProIf OBJECT IDENTIFIER ::= { sleMplsTpNode 2 }
|
|
|
|
|
|
sleMplsTpProIfInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SleMplsTpProIfInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
::= { sleMplsTpProIf 1 }
|
|
|
|
|
|
sleMplsTpProIfInfoEntry OBJECT-TYPE
|
|
SYNTAX SleMplsTpProIfInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
INDEX { sleMplsTPProIfInfoIfIndex }
|
|
::= { sleMplsTpProIfInfoTable 1 }
|
|
|
|
|
|
SleMplsTpProIfInfoEntry ::=
|
|
SEQUENCE {
|
|
sleMplsTPProIfInfoIfIndex
|
|
Unsigned32,
|
|
sleMplsTPProIfInfoIpAddr
|
|
IpAddress
|
|
}
|
|
|
|
sleMplsTPProIfInfoIfIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used in accommodating the bigger
|
|
size Global_Node_ID and/or ICC with lower size LSR
|
|
identifier in order to index the mplsTunnelTable.
|
|
|
|
The Local Identifier is configured between 1 and 16777215,
|
|
as valid IP address range starts from 16777216(01.00.00.00).
|
|
This range is chosen to identify the mplsTunnelTable's
|
|
Ingress/Egress LSR-id is IP address or Local identifier,
|
|
if the configured range is not IP address, administrator is
|
|
expected to retrieve the complete information
|
|
(Global_Node_ID or ICC) from mplsTunnelExtNodeConfigTable.
|
|
This way, existing mplsTunnelTable is reused for
|
|
bidirectional tunnel extensions for MPLS based transport networks.
|
|
|
|
This Local Identifier allows the administrator to assign
|
|
a unique identifier to map Global_Node_ID and/or ICC."
|
|
::= { sleMplsTpProIfInfoEntry 1 }
|
|
|
|
|
|
sleMplsTPProIfInfoIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
::= { sleMplsTpProIfInfoEntry 2 }
|
|
|
|
|
|
sleMplsTpProIfControl OBJECT IDENTIFIER ::= { sleMplsTpProIf 2 }
|
|
|
|
|
|
sleMplsTpProIfControlRequest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
setMplsTpProIfIpAddr(1),
|
|
unSetMplsTpProIfIpAddr(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the possible read-write columns that
|
|
can be modified in the TunnelExtNodeConfigTable table.
|
|
For each read-write column of TunnelExtNodeConfigTable table,
|
|
a Set Operation control value is added in this object."
|
|
::= { sleMplsTpProIfControl 1 }
|
|
|
|
|
|
sleMplsTpProIfControlStatus OBJECT-TYPE
|
|
SYNTAX SleControlStatusType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the status of the configuration done."
|
|
::= { sleMplsTpProIfControl 2 }
|
|
|
|
|
|
sleMplsTpProIfControlTimer OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is based on the SLE style where a timer is configured for every control table."
|
|
::= { sleMplsTpProIfControl 3 }
|
|
|
|
|
|
sleMplsTpProIfControlTimestamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the time at which the configuration is done."
|
|
::= { sleMplsTpProIfControl 4 }
|
|
|
|
|
|
sleMplsTpProIfControlReqResult OBJECT-TYPE
|
|
SYNTAX SleControlRequestResultType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The standard result of the SET operation is stored here."
|
|
::= { sleMplsTpProIfControl 5 }
|
|
|
|
|
|
sleMplsTpProIfControlIfIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
::= { sleMplsTpProIfControl 6 }
|
|
|
|
|
|
sleMplsTpProIfControlIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Global Operator Identifier."
|
|
REFERENCE
|
|
"MPLS-TP Identifiers [RFC6370]."
|
|
::= { sleMplsTpProIfControl 7 }
|
|
|
|
|
|
|
|
END
|
|
|
|
--
|
|