1341 lines
32 KiB
Plaintext
1341 lines
32 KiB
Plaintext
--
|
|
-- sle-mpls-tp-pw-mib.mib
|
|
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
|
|
-- Friday, February 05, 2016 at 10:43:40
|
|
--
|
|
|
|
SLE-MPLS-TP-PW-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
sleMgmt
|
|
FROM DASAN-SMI
|
|
IANAPwTypeTC
|
|
FROM IANA-PWE3-MIB
|
|
InterfaceIndexOrZero
|
|
FROM IF-MIB
|
|
MplsCcId, MplsIccId
|
|
FROM MPLS-TC-EXT-STD-MIB
|
|
MplsLabel
|
|
FROM MPLS-TC-STD-MIB
|
|
PwIDType, PwGroupID
|
|
FROM PW-TC-STD-MIB
|
|
VlanIdOrAnyOrNone
|
|
FROM Q-BRIDGE-MIB
|
|
SleControlStatusType, SleControlRequestResultType
|
|
FROM SLE-TC-MIB
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
transmission, TimeTicks, IpAddress, Unsigned32, Gauge32,
|
|
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
|
|
FROM SNMPv2-SMI;
|
|
|
|
|
|
sleMplsTpPw MODULE-IDENTITY
|
|
LAST-UPDATED "201511030000Z" -- November 03, 2015 at 00:00 GMT
|
|
ORGANIZATION
|
|
"Dasan Networks"
|
|
CONTACT-INFO
|
|
"Gyerok Kwon
|
|
Dasan Networks
|
|
Email: grkwon@dasannetworks.com
|
|
|
|
Kantharaj B M
|
|
Dasan Networks
|
|
Email: kanth@dasannetworks.com
|
|
|
|
DongChel Shin (Chris)
|
|
Dasan Networks
|
|
Email: dchshin@dasannetworks.com
|
|
|
|
Comments about this document should be emailed
|
|
directly to the Dasan support email ID at
|
|
support@dasannetworks.com."
|
|
DESCRIPTION
|
|
"This MIB module containg the managed object definition for
|
|
MPLS-TP pseudowire(PW) operation.
|
|
|
|
copyright (c) 2015 Dasan Networks and the persons identified
|
|
as authors of the code. All rights reserved."
|
|
REVISION "201511030000Z" -- November 03, 2015 at 00:00 GMT
|
|
DESCRIPTION
|
|
"Initial version."
|
|
::= { sleMpls 15 }
|
|
|
|
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
sleMpls OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SLE MPLS."
|
|
::= { sleMgmt 16 }
|
|
|
|
|
|
sleMplsTpPwCfg OBJECT IDENTIFIER ::= { sleMplsTpPw 1 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SleMplsTpPwCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table specifies information for configuring and
|
|
status monitoring that is common to all service types
|
|
and PSN types."
|
|
::= { sleMplsTpPwCfg 1 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoEntry OBJECT-TYPE
|
|
SYNTAX SleMplsTpPwCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in this table is indexed by
|
|
sleMplsTpPwCfgInfoId."
|
|
INDEX { sleMplsTpPwCfgInfoId }
|
|
::= { sleMplsTpPwCfgInfoTable 1 }
|
|
|
|
|
|
SleMplsTpPwCfgInfoEntry ::=
|
|
SEQUENCE {
|
|
sleMplsTpPwCfgInfoId
|
|
PwIDType,
|
|
sleMplsTpPwCfgInfoName
|
|
OCTET STRING,
|
|
sleMplsTpPwCfgInfoOwner
|
|
INTEGER,
|
|
sleMplsTpPwCfgInfoType
|
|
IANAPwTypeTC,
|
|
sleMplsTpPwCfgInfoControlWord
|
|
INTEGER,
|
|
sleMplsTpPwCfgInfoPeerIdType
|
|
INTEGER,
|
|
sleMplsTpPwCfgInfoPeerGolbalId
|
|
Unsigned32,
|
|
sleMplsTpPwCfgInfoPeerCc
|
|
MplsCcId,
|
|
sleMplsTpPwCfgInfoPeerIcc
|
|
MplsIccId,
|
|
sleMplsTpPwCfgInfoPeerNodeId
|
|
IpAddress,
|
|
sleMplsTpPwCfgInfoPeerAcId
|
|
Unsigned32,
|
|
sleMplsTpPwCfgInfoGroupName
|
|
SnmpAdminString,
|
|
sleMplsTpPwCfgInfoGroupId
|
|
PwGroupID,
|
|
sleMplsTpPwCfgInfoOperMode
|
|
INTEGER,
|
|
sleMplsTpPwCfgInfoSvlanId
|
|
VlanIdOrAnyOrNone,
|
|
sleMplsTpPwCfgInfoPwStatus
|
|
INTEGER,
|
|
sleMplsTpPwCfgInfoInlabel
|
|
MplsLabel,
|
|
sleMplsTpPwCfgInfoOutLabel
|
|
MplsLabel,
|
|
sleMplsTpPwCfgInfoTunnelName
|
|
OCTET STRING,
|
|
sleMplsTpPwCfgInfoAcInterfaceIndex
|
|
InterfaceIndexOrZero,
|
|
sleMplsTpPwCfgInfoVcStitchName
|
|
OCTET STRING,
|
|
sleMplsTpPwCfgInfoPriority
|
|
INTEGER,
|
|
sleMplsTpPwCfgInfostate
|
|
INTEGER,
|
|
sleMplsTpPwCfgInfoDescription
|
|
OCTET STRING,
|
|
sleMplsTpPwCfgInfoLocalRefreshTimer
|
|
INTEGER,
|
|
sleMplsTpPwCfgInfoQosServicePolicy
|
|
OCTET STRING
|
|
}
|
|
|
|
sleMplsTpPwCfgInfoId OBJECT-TYPE
|
|
SYNTAX PwIDType (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Virtual Circuit ID."
|
|
::= { sleMplsTpPwCfgInfoEntry 1 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Virtual Circuit Name. It identifies an entry
|
|
on this table."
|
|
::= { sleMplsTpPwCfgInfoEntry 2 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoOwner OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
manual(1),
|
|
pwIdFecSignaling(2),
|
|
genFecSignaling(3),
|
|
l2tpControlProtocol(4),
|
|
other(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use to indentify the owner of the PW."
|
|
::= { sleMplsTpPwCfgInfoEntry 3 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoType OBJECT-TYPE
|
|
SYNTAX IANAPwTypeTC
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service type of the PW."
|
|
::= { sleMplsTpPwCfgInfoEntry 4 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoControlWord OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of Control Word negotiation."
|
|
::= { sleMplsTpPwCfgInfoEntry 5 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoPeerIdType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ietf(1),
|
|
itut(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Peer Id Type"
|
|
::= { sleMplsTpPwCfgInfoEntry 6 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoPeerGolbalId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Peer Global ID."
|
|
::= { sleMplsTpPwCfgInfoEntry 7 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoPeerCc OBJECT-TYPE
|
|
SYNTAX MplsCcId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Peer Country Code(cc)."
|
|
::= { sleMplsTpPwCfgInfoEntry 8 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoPeerIcc OBJECT-TYPE
|
|
SYNTAX MplsIccId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Peer ICC."
|
|
::= { sleMplsTpPwCfgInfoEntry 9 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoPeerNodeId OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Peer Node Id."
|
|
::= { sleMplsTpPwCfgInfoEntry 10 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoPeerAcId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Peer Attachment circuit ID."
|
|
::= { sleMplsTpPwCfgInfoEntry 11 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoGroupName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Local Group name."
|
|
::= { sleMplsTpPwCfgInfoEntry 12 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoGroupId OBJECT-TYPE
|
|
SYNTAX PwGroupID
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Local Group Id."
|
|
::= { sleMplsTpPwCfgInfoEntry 13 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoOperMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none(0),
|
|
pwRawMode(1),
|
|
pwTaggedMode(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Current Operation mode."
|
|
::= { sleMplsTpPwCfgInfoEntry 14 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoSvlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrAnyOrNone
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW SVlan. This should be a valid VLAN-ID when
|
|
sleMplsTpPwCfgOperMode is pwTaggedMode(2)."
|
|
DEFVAL { 0 }
|
|
::= { sleMplsTpPwCfgInfoEntry 15 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoPwStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set the pw status tlv."
|
|
::= { sleMplsTpPwCfgInfoEntry 17 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoInlabel OBJECT-TYPE
|
|
SYNTAX MplsLabel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW FIB Entry OutLabel."
|
|
::= { sleMplsTpPwCfgInfoEntry 18 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoOutLabel OBJECT-TYPE
|
|
SYNTAX MplsLabel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW FIB entry InLabel."
|
|
::= { sleMplsTpPwCfgInfoEntry 19 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoTunnelName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0 | 1..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW FIB Entry Tunnel Name."
|
|
::= { sleMplsTpPwCfgInfoEntry 20 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoAcInterfaceIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW FIB Entry Interface Index."
|
|
::= { sleMplsTpPwCfgInfoEntry 21 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoVcStitchName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Multi-segment PW FIB entry stitch name."
|
|
::= { sleMplsTpPwCfgInfoEntry 22 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoPriority OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
primary(1),
|
|
secondary(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Priority. In MPLS-TP case, primary only supported."
|
|
::= { sleMplsTpPwCfgInfoEntry 23 }
|
|
|
|
|
|
sleMplsTpPwCfgInfostate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Pw state "
|
|
DEFVAL { down }
|
|
::= { sleMplsTpPwCfgInfoEntry 24 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Description."
|
|
::= { sleMplsTpPwCfgInfoEntry 25 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoLocalRefreshTimer OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"pw local refresh timer."
|
|
::= { sleMplsTpPwCfgInfoEntry 26 }
|
|
|
|
|
|
sleMplsTpPwCfgInfoQosServicePolicy OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"pw qos input service policy."
|
|
::= { sleMplsTpPwCfgInfoEntry 27 }
|
|
|
|
|
|
sleMplsTpPwCfgControl OBJECT IDENTIFIER ::= { sleMplsTpPwCfg 2 }
|
|
|
|
|
|
sleMplsTpPwCfgControlRequest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
createPw(1),
|
|
createVpwsWithGroupId(2),
|
|
createRawModeVpwsWithGroupId(3),
|
|
createQInQVpwsWithGroupId(4),
|
|
createRawModeVpws(5),
|
|
createQInQVpws(6),
|
|
deletePw(7),
|
|
setPwFibEntry(8),
|
|
setPwVcStitchFibEntry(9),
|
|
unsetPwFibEntry(10),
|
|
setPwDescription(11),
|
|
createVpwswithPwStatus(12),
|
|
setPwQosServicePolicy(13),
|
|
unsetPwQosServicePolicy(14)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the possible read-write columns that can be modified
|
|
in the Pw table. For each read-write column of Pw table, a Set
|
|
Operation control value is added in this object."
|
|
::= { sleMplsTpPwCfgControl 1 }
|
|
|
|
|
|
sleMplsTpPwCfgControlStatus OBJECT-TYPE
|
|
SYNTAX SleControlStatusType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the status of the configuration done."
|
|
::= { sleMplsTpPwCfgControl 2 }
|
|
|
|
|
|
sleMplsTpPwCfgControlTimer OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is based on the SLE style where a timer is configured for every control table."
|
|
::= { sleMplsTpPwCfgControl 3 }
|
|
|
|
|
|
sleMplsTpPwCfgControlTimestamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the time at which the configuration is done."
|
|
::= { sleMplsTpPwCfgControl 4 }
|
|
|
|
|
|
sleMplsTpPwCfgControlReqResult OBJECT-TYPE
|
|
SYNTAX SleControlRequestResultType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The standard result of the SET operation is stored here."
|
|
::= { sleMplsTpPwCfgControl 5 }
|
|
|
|
|
|
sleMplsTpPwCfgControlId OBJECT-TYPE
|
|
SYNTAX PwIDType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Virtual Circuit ID."
|
|
::= { sleMplsTpPwCfgControl 6 }
|
|
|
|
|
|
sleMplsTpPwCfgControlName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Virtual Circuit Name. It identifies an entry
|
|
on this table."
|
|
::= { sleMplsTpPwCfgControl 7 }
|
|
|
|
|
|
sleMplsTpPwCfgControlOwner OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
manual(1),
|
|
pwIdFecSignaling(2),
|
|
genFecSignaling(3),
|
|
l2tpControlProtocol(4),
|
|
other(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use to indentify the owner of the PW."
|
|
::= { sleMplsTpPwCfgControl 8 }
|
|
|
|
|
|
sleMplsTpPwCfgControlPeerIdType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ietf(1),
|
|
itut(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Peer Id Type"
|
|
::= { sleMplsTpPwCfgControl 9 }
|
|
|
|
|
|
sleMplsTpPwCfgControlPeerGolbalId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Peer Global ID."
|
|
::= { sleMplsTpPwCfgControl 10 }
|
|
|
|
|
|
sleMplsTpPwCfgControlPeerCc OBJECT-TYPE
|
|
SYNTAX MplsCcId
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Peer Country Code(cc)."
|
|
::= { sleMplsTpPwCfgControl 11 }
|
|
|
|
|
|
sleMplsTpPwCfgControlPeerIcc OBJECT-TYPE
|
|
SYNTAX MplsIccId
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Peer ICC."
|
|
::= { sleMplsTpPwCfgControl 12 }
|
|
|
|
|
|
sleMplsTpPwCfgControlPeerNodeId OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Peer Node Id."
|
|
::= { sleMplsTpPwCfgControl 13 }
|
|
|
|
|
|
sleMplsTpPwCfgControlPeerAcId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Peer Attachment circuit ID."
|
|
::= { sleMplsTpPwCfgControl 14 }
|
|
|
|
|
|
sleMplsTpPwCfgControlGroupName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Local Group name."
|
|
::= { sleMplsTpPwCfgControl 15 }
|
|
|
|
|
|
sleMplsTpPwCfgControlGroupId OBJECT-TYPE
|
|
SYNTAX PwGroupID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Local Group Id."
|
|
::= { sleMplsTpPwCfgControl 16 }
|
|
|
|
|
|
sleMplsTpPwCfgControlOperMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
pwRawMode(1),
|
|
pwTaggedMode(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Current Operation mode."
|
|
::= { sleMplsTpPwCfgControl 17 }
|
|
|
|
|
|
sleMplsTpPwCfgControlSvlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrAnyOrNone
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW SVlan. This should be a valid VLAN-ID when
|
|
sleMplsTpPwCfgOperMode is pwTaggedMode(2)."
|
|
::= { sleMplsTpPwCfgControl 18 }
|
|
|
|
|
|
sleMplsTpPwCfgControlInlabel OBJECT-TYPE
|
|
SYNTAX MplsLabel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW FIB Entry OutLabel."
|
|
::= { sleMplsTpPwCfgControl 20 }
|
|
|
|
|
|
sleMplsTpPwCfgControlOutLabel OBJECT-TYPE
|
|
SYNTAX MplsLabel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW FIB entry InLabel."
|
|
::= { sleMplsTpPwCfgControl 21 }
|
|
|
|
|
|
sleMplsTpPwCfgControlTunnelName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0 | 1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW FIB Entry Tunnel Name."
|
|
::= { sleMplsTpPwCfgControl 22 }
|
|
|
|
|
|
sleMplsTpPwCfgControlAcInterfaceIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW FIB Entry Interface Index."
|
|
::= { sleMplsTpPwCfgControl 23 }
|
|
|
|
|
|
sleMplsTpPwCfgControlVcStitchName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Multi-segmen PW FIB Entry stitch name."
|
|
::= { sleMplsTpPwCfgControl 24 }
|
|
|
|
|
|
sleMplsTpPwCfgControlDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Description."
|
|
::= { sleMplsTpPwCfgControl 26 }
|
|
|
|
|
|
sleMplsTpPwCfgControlPwStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set the pw status tlv."
|
|
::= { sleMplsTpPwCfgControl 27 }
|
|
|
|
|
|
sleMplsTpPwCfgControlLocalRefreshTimer OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Status Local Refresh Timer."
|
|
::= { sleMplsTpPwCfgControl 28 }
|
|
|
|
|
|
sleMplsTpPwCfgControlQosServicePolicy OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW qos input service policy."
|
|
::= { sleMplsTpPwCfgControl 29 }
|
|
|
|
|
|
sleMplsTpPwAcCfg OBJECT IDENTIFIER ::= { sleMplsTpPw 2 }
|
|
|
|
|
|
sleMplsTpPwAcCfgInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SleMplsTpPwAcCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table specifies information for binding the PW on
|
|
the MPLS-TP service provider interface."
|
|
::= { sleMplsTpPwAcCfg 1 }
|
|
|
|
|
|
sleMplsTpPwAcCfgInfoEntry OBJECT-TYPE
|
|
SYNTAX SleMplsTpPwAcCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in this table is indexed by
|
|
sleMplsTpPwIfIndexInfo."
|
|
INDEX { sleMplsTpPwAcCfgInfoIndex }
|
|
::= { sleMplsTpPwAcCfgInfoTable 1 }
|
|
|
|
|
|
SleMplsTpPwAcCfgInfoEntry ::=
|
|
SEQUENCE {
|
|
sleMplsTpPwAcCfgInfoIndex
|
|
InterfaceIndexOrZero,
|
|
sleMplsTpPwAcCfgInfoLocalAcId
|
|
Unsigned32
|
|
}
|
|
|
|
sleMplsTpPwAcCfgInfoIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Customer-facing/service-provider Interface Index."
|
|
::= { sleMplsTpPwAcCfgInfoEntry 1 }
|
|
|
|
|
|
sleMplsTpPwAcCfgInfoLocalAcId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Local AC Id of MPLS-TP service provider interface."
|
|
::= { sleMplsTpPwAcCfgInfoEntry 2 }
|
|
|
|
|
|
sleMplsTpPwAcCfgControl OBJECT IDENTIFIER ::= { sleMplsTpPwAcCfg 2 }
|
|
|
|
|
|
sleMplsTpPwAcCfgControlRequest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
setPwLocalACId(1),
|
|
unsetPwIfLocalACId(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the possible read-write columns that can be modified
|
|
in the sleMplsTpPwIfCfg table. For each read-write column of
|
|
sleMplsTpPwIfCfg table, a Set Operation control value is
|
|
added in this object."
|
|
::= { sleMplsTpPwAcCfgControl 1 }
|
|
|
|
|
|
sleMplsTpPwAcCfgControlStatus OBJECT-TYPE
|
|
SYNTAX SleControlStatusType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the status of the configuration done."
|
|
::= { sleMplsTpPwAcCfgControl 2 }
|
|
|
|
|
|
sleMplsTpPwAcCfgControlTimer OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is based on the SLE style where a timer is configured for every control table."
|
|
::= { sleMplsTpPwAcCfgControl 3 }
|
|
|
|
|
|
sleMplsTpPwAcCfgControlTimestamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the time at which the configuration is done."
|
|
::= { sleMplsTpPwAcCfgControl 4 }
|
|
|
|
|
|
sleMplsTpPwAcCfgControlReqResult OBJECT-TYPE
|
|
SYNTAX SleControlRequestResultType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The standard result of the SET operation is stored here."
|
|
::= { sleMplsTpPwAcCfgControl 5 }
|
|
|
|
|
|
sleMplsTpPwAcCfgControlIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Customer-facing/service-provider Interface Index."
|
|
::= { sleMplsTpPwAcCfgControl 6 }
|
|
|
|
|
|
sleMplsTpPwAcCfgControlLocalAcId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Local AC Id of MPLS-TP service provider interface."
|
|
::= { sleMplsTpPwAcCfgControl 7 }
|
|
|
|
|
|
sleMplsTpPwIfCfg OBJECT IDENTIFIER ::= { sleMplsTpPw 3 }
|
|
|
|
|
|
sleMplsTpPwIfCfgInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SleMplsTpPwIfCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table specifies information for binding the PW on
|
|
the MPLS-TP service provider interface."
|
|
::= { sleMplsTpPwIfCfg 1 }
|
|
|
|
|
|
sleMplsTpPwIfCfgInfoEntry OBJECT-TYPE
|
|
SYNTAX SleMplsTpPwIfCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in this table is indexed by
|
|
sleMplsTpPwIfIndexInfo."
|
|
INDEX { sleMplsTpPwIfCfgInfoIndex, sleMplsTpPwIfCfgInfoVcName }
|
|
::= { sleMplsTpPwIfCfgInfoTable 1 }
|
|
|
|
|
|
SleMplsTpPwIfCfgInfoEntry ::=
|
|
SEQUENCE {
|
|
sleMplsTpPwIfCfgInfoIndex
|
|
InterfaceIndexOrZero,
|
|
sleMplsTpPwIfCfgInfoVcName
|
|
OCTET STRING,
|
|
sleMplsTpPwIfCfgInfoServiceType
|
|
IANAPwTypeTC,
|
|
sleMplsTpPwIfCfgInfoVlanId
|
|
VlanIdOrAnyOrNone,
|
|
sleMplsTpPwIfCfgInfoPriority
|
|
INTEGER,
|
|
sleMplsTpPwIfCfgInfoSVlanId
|
|
VlanIdOrAnyOrNone,
|
|
sleMplsTpPwIfCfgInfoInnerVlanId
|
|
VlanIdOrAnyOrNone,
|
|
sleMplsTpPwIfCfgInfoAction
|
|
INTEGER
|
|
}
|
|
|
|
sleMplsTpPwIfCfgInfoIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Customer-facing/service-provider Interface Index."
|
|
::= { sleMplsTpPwIfCfgInfoEntry 1 }
|
|
|
|
|
|
sleMplsTpPwIfCfgInfoVcName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Name which bind on interface."
|
|
::= { sleMplsTpPwIfCfgInfoEntry 2 }
|
|
|
|
|
|
sleMplsTpPwIfCfgInfoServiceType OBJECT-TYPE
|
|
SYNTAX IANAPwTypeTC
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service Type of PW bind on interface."
|
|
::= { sleMplsTpPwIfCfgInfoEntry 3 }
|
|
|
|
|
|
sleMplsTpPwIfCfgInfoVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrAnyOrNone
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN ID of bind PW. It should have valid value when
|
|
sleMplsTpPwIfCfgServiceType is ethernetTagged."
|
|
::= { sleMplsTpPwIfCfgInfoEntry 4 }
|
|
|
|
|
|
sleMplsTpPwIfCfgInfoPriority OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
primary(1),
|
|
secondary(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Priority of bind PW."
|
|
::= { sleMplsTpPwIfCfgInfoEntry 5 }
|
|
|
|
|
|
sleMplsTpPwIfCfgInfoSVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrAnyOrNone
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN ID of bind PW. It should have valid value when
|
|
sleMplsTpPwIfCfgServiceType is ethernetTagged."
|
|
::= { sleMplsTpPwIfCfgInfoEntry 6 }
|
|
|
|
|
|
sleMplsTpPwIfCfgInfoInnerVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrAnyOrNone
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN ID of bind PW. It should have valid value when
|
|
sleMplsTpPwIfCfgServiceType is ethernetTagged."
|
|
::= { sleMplsTpPwIfCfgInfoEntry 7 }
|
|
|
|
|
|
sleMplsTpPwIfCfgInfoAction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noOp(1),
|
|
addSvlan(2),
|
|
remove(3),
|
|
replace(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action of Pw."
|
|
::= { sleMplsTpPwIfCfgInfoEntry 8 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControl OBJECT IDENTIFIER ::= { sleMplsTpPwIfCfg 2 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlRequest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
setPwBindwithRaw(1),
|
|
setPwBindwithTagged(2),
|
|
unsetPwBindwithRaw(3),
|
|
unsetPwBindwithTagged(4),
|
|
setPWBindWithRawSvlanIdAction(5),
|
|
setPWBindWithRawSvlanIdTPIDActionPriority(6),
|
|
setPWBindWithTaggedTpidAction(7),
|
|
setPwbindWithTaggedTpidActionPriority(8),
|
|
setPWBindWithQinQ(9),
|
|
setPWBindWithQinQPrority(10),
|
|
setPWBindWithQinQTpidAction(11),
|
|
setPWBindWithQinQTpidActionPriority(12)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the possible read-write columns that can be modified
|
|
in the sleMplsTpPwIfCfg table. For each read-write column of
|
|
sleMplsTpPwIfCfg table, a Set Operation control value is
|
|
added in this object."
|
|
::= { sleMplsTpPwIfCfgControl 1 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlStatus OBJECT-TYPE
|
|
SYNTAX SleControlStatusType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the status of the configuration done."
|
|
::= { sleMplsTpPwIfCfgControl 2 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlTimer OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is based on the SLE style where a timer is configured for every control table."
|
|
::= { sleMplsTpPwIfCfgControl 3 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlTimestamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the time at which the configuration is done."
|
|
::= { sleMplsTpPwIfCfgControl 4 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlReqResult OBJECT-TYPE
|
|
SYNTAX SleControlRequestResultType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The standard result of the SET operation is stored here."
|
|
::= { sleMplsTpPwIfCfgControl 5 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Customer-facing/service-provider Interface Index."
|
|
::= { sleMplsTpPwIfCfgControl 6 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlVcName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Name which bind on interface."
|
|
::= { sleMplsTpPwIfCfgControl 7 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlServiceType OBJECT-TYPE
|
|
SYNTAX IANAPwTypeTC
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service Type of PW bind on interface."
|
|
::= { sleMplsTpPwIfCfgControl 8 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrAnyOrNone
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN ID of bind PW. It should have valid value when
|
|
sleMplsTpPwIfCfgServiceType is ethernetTagged."
|
|
::= { sleMplsTpPwIfCfgControl 9 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlPriority OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
primary(1),
|
|
secondary(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Priority of bind PW."
|
|
::= { sleMplsTpPwIfCfgControl 10 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlSVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrAnyOrNone
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN ID of bind PW. It should have valid value when
|
|
sleMplsTpPwIfCfgServiceType is ethernetTagged."
|
|
::= { sleMplsTpPwIfCfgControl 11 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlInnerVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrAnyOrNone
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN ID of bind PW. It should have valid value when
|
|
sleMplsTpPwIfCfgServiceType is ethernetTagged."
|
|
::= { sleMplsTpPwIfCfgControl 12 }
|
|
|
|
|
|
sleMplsTpPwIfCfgControlAction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noOp(1),
|
|
addSvlan(2),
|
|
remove(3),
|
|
replace(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action of Pw."
|
|
::= { sleMplsTpPwIfCfgControl 13 }
|
|
|
|
|
|
sleMplsTpMsPwCfg OBJECT IDENTIFIER ::= { sleMplsTpPw 4 }
|
|
|
|
|
|
sleMplsTpMsPwCfgInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SleMplsTpMsPwCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table specifies information for Multisegment
|
|
PW."
|
|
::= { sleMplsTpMsPwCfg 1 }
|
|
|
|
|
|
sleMplsTpMsPwCfgInfoEntry OBJECT-TYPE
|
|
SYNTAX SleMplsTpMsPwCfgInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in this table is indexed by
|
|
sleMplsTpMsPwCfgName."
|
|
INDEX { sleMplsTpMsPwCfgInfoName }
|
|
::= { sleMplsTpMsPwCfgInfoTable 1 }
|
|
|
|
|
|
SleMplsTpMsPwCfgInfoEntry ::=
|
|
SEQUENCE {
|
|
sleMplsTpMsPwCfgInfoName
|
|
OCTET STRING,
|
|
sleMplsTpMsPwCfgInfoSegment1Name
|
|
OCTET STRING,
|
|
sleMplsTpMsPwCfgInfoSegment2Name
|
|
OCTET STRING,
|
|
sleMplsTpMsPwCfgInfoDescription
|
|
OCTET STRING,
|
|
sleMplsTpMsPwCfgInfoMtu
|
|
INTEGER,
|
|
sleMplsTpMsPwCfgInfoServiceType
|
|
IANAPwTypeTC,
|
|
sleMplsTpMsPwCfgInfoVlanId
|
|
VlanIdOrAnyOrNone
|
|
}
|
|
|
|
sleMplsTpMsPwCfgInfoName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Multi-segment PW stitch name."
|
|
::= { sleMplsTpMsPwCfgInfoEntry 1 }
|
|
|
|
|
|
sleMplsTpMsPwCfgInfoSegment1Name OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Segment 1."
|
|
::= { sleMplsTpMsPwCfgInfoEntry 2 }
|
|
|
|
|
|
sleMplsTpMsPwCfgInfoSegment2Name OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW segment 2."
|
|
::= { sleMplsTpMsPwCfgInfoEntry 3 }
|
|
|
|
|
|
sleMplsTpMsPwCfgInfoDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Multi-segment stitch description."
|
|
::= { sleMplsTpMsPwCfgInfoEntry 4 }
|
|
|
|
|
|
sleMplsTpMsPwCfgInfoMtu OBJECT-TYPE
|
|
SYNTAX INTEGER (68..9216)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MTU size.
|
|
|
|
Interface MTU size - needed when one vc is not signaled.
|
|
"
|
|
::= { sleMplsTpMsPwCfgInfoEntry 5 }
|
|
|
|
|
|
sleMplsTpMsPwCfgInfoServiceType OBJECT-TYPE
|
|
SYNTAX IANAPwTypeTC
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service type."
|
|
::= { sleMplsTpMsPwCfgInfoEntry 6 }
|
|
|
|
|
|
sleMplsTpMsPwCfgInfoVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrAnyOrNone
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN Id."
|
|
::= { sleMplsTpMsPwCfgInfoEntry 7 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControl OBJECT IDENTIFIER ::= { sleMplsTpMsPwCfg 2 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControlRequest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
createMsPw(1),
|
|
createMsPwWithMtuAndServiceType(2),
|
|
deleteMsPw(3),
|
|
setMsPwDescription(4),
|
|
unsetMsPwDescription(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the possible read-write columns that can be modified
|
|
in the sleMplsTpMsPwCfg table. For each read-write column of
|
|
sleMplsTpMsPwCfg table, a Set Operation control value is
|
|
added in this object."
|
|
::= { sleMplsTpMsPwCfgControl 1 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControlStatus OBJECT-TYPE
|
|
SYNTAX SleControlStatusType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the status of the configuration done."
|
|
::= { sleMplsTpMsPwCfgControl 2 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControlTimer OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is based on the SLE style where a timer is configured for every control table."
|
|
::= { sleMplsTpMsPwCfgControl 3 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControlTimestamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the time at which the configuration is done."
|
|
::= { sleMplsTpMsPwCfgControl 4 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControlReqResult OBJECT-TYPE
|
|
SYNTAX SleControlRequestResultType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The standard result of the SET operation is stored here."
|
|
::= { sleMplsTpMsPwCfgControl 5 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControlName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Multi-segment PW stitch name."
|
|
::= { sleMplsTpMsPwCfgControl 6 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControlSegment1Name OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Segment 1."
|
|
::= { sleMplsTpMsPwCfgControl 7 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControlSegment2Name OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PW Segment 2."
|
|
::= { sleMplsTpMsPwCfgControl 8 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControlDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Multi-segment stitch description."
|
|
::= { sleMplsTpMsPwCfgControl 9 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControlMtu OBJECT-TYPE
|
|
SYNTAX INTEGER (68..9216)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MTU size.
|
|
|
|
Interface MTU size - needed when one vc is not signaled."
|
|
::= { sleMplsTpMsPwCfgControl 10 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControlServiceType OBJECT-TYPE
|
|
SYNTAX IANAPwTypeTC
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service Type."
|
|
::= { sleMplsTpMsPwCfgControl 11 }
|
|
|
|
|
|
sleMplsTpMsPwCfgControlVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrAnyOrNone
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN Id."
|
|
::= { sleMplsTpMsPwCfgControl 12 }
|
|
|
|
|
|
|
|
END
|
|
|
|
--
|
|
-- sle-mpls-tp-pw-mib.mib
|
|
--
|