mibs/MIBS/dasan/SLE-RMON-MIB
2023-12-05 12:25:34 +01:00

2987 lines
92 KiB
Plaintext

--
-- sle-rmon-mib.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
-- Tuesday, December 22, 2015 at 14:23:02
--
-- SLE-RMON-MIB.my
-- MIB generated by MG-SOFT Visual MIB Builder Version 3.0 Build 285
-- Monday, January 22, 2007 at 16:52:34
--
SLE-RMON-MIB DEFINITIONS ::= BEGIN
IMPORTS
sleMgmt
FROM DASAN-SMI
SleControlStatusType, SleControlRequestResultType
FROM SLE-TC-MIB
OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
TimeTicks, Integer32, Gauge32, Counter32, OBJECT-TYPE,
MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC;
-- sle
-- FROM AN-MIB
--
-- 1.3.6.1.4.1.6296.101.9
-- December 08, 2004 at 09:03 GMT
-- December 08, 2004 at 08:40 GMT
-- 1.3.6.1.4.1.6296.101.9
sleRmon MODULE-IDENTITY
LAST-UPDATED "200412080903Z" -- December 08, 2004 at 09:03 GMT
ORGANIZATION
"ORGANIZATION"
CONTACT-INFO
"Contact "
DESCRIPTION
"This MIB contains all needed informations about rmon and
all supported sle rmon features."
REVISION "200412080840Z" -- December 08, 2004 at 08:40 GMT
DESCRIPTION
"AFI"
::= { sleMgmt 9 }
--
-- Type definitions
--
-- Type definitions
--
-- ::= { sle 14 }
-- textual conventions
OwnerString ::= OCTET STRING (SIZE (0..255))
-- This data type is used to model an administratively
-- assigned name of the owner of a resource. This
-- information is taken from the NVT ASCII character
-- set. It is suggested that this name contain one or
-- more of the following: IP address, management station
-- name, network manager's name, location, or phone
-- number.
-- In some cases the agent itself will be the owner of
-- an entry. In these cases, this string shall be set
-- to a string starting with 'monitor'.
--
-- SNMP access control is articulated entirely in terms
-- of the contents of MIB views; access to a particular
-- SNMP object instance depends only upon its presence
-- or absence in a particular MIB view and never upon
-- its value or the value of related object instances.
-- Thus, objects of this type afford resolution of
-- resource contention only among cooperating managers;
-- they realize no access control function with respect
-- to uncooperative parties.
--
-- By convention, objects with this syntax are declared as
-- having
--
-- SIZE (0..127)
SleEntryStatus ::= INTEGER
{
valid(1),
createRequest(2),
underCreation(3)
}
--
-- Node definitions
--
-- Node definitions
--
-- 1.3.6.1.4.1.6296.101.9.1
-- 1.3.6.1.4.1.6296.101.9.1
sleHistory OBJECT IDENTIFIER ::= { sleRmon 1 }
-- The sleHistory Control Group
-- Implementation of the History Control group is optional.
--
-- The sleHistory control group controls the periodic statistical
-- sampling of data from various types of networks. The
-- historyControlTable stores configuration entries that each
-- define an interface, polling period, and other parameters.
-- Once samples are taken, their data is stored in an entry
-- in a media-specific table. Each such entry defines one
-- sample, and is associated with the historyControlEntry that
-- caused the sample to be taken. Each counter in the
-- etherHistoryEntry counts the same event as its
-- similarly-named counterpart in the etherStatsEntry,
-- except that each value here is a cumulative sum during a
-- sampling period.
--
-- If the probe keeps track of the time of day, it should
-- start the first sample of the history at a time such that
-- when the next hour of the day begins, a sample is
-- started at that instant. This tends to make more
-- user-friendly reports, and enables comparison of reports
-- from different probes that have relatively accurate time
-- of day.
--
-- The probe is encouraged to add two history control entries
-- per monitored interface upon initialization that describe
-- a short term and a long term polling period. Suggested
-- parameters are 30 seconds for the short term polling period
-- and 30 minutes for the long term period.
-- 1.3.6.1.4.1.6296.101.9.1.1
-- 1.3.6.1.4.1.6296.101.9.1.1
sleHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of history control entries."
::= { sleHistory 1 }
-- 1.3.6.1.4.1.6296.101.9.1.1.1
-- 1.3.6.1.4.1.6296.101.9.1.1.1
sleHistoryEntry OBJECT-TYPE
SYNTAX SleHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of parameters that set up a periodic sampling
of statistics. As an example, an instance of the
sleHistoryControlInterval object might be named
sleHistoryControlInterval.2"
INDEX { sleHistoryIndex }
::= { sleHistoryTable 1 }
SleHistoryEntry ::=
SEQUENCE {
sleHistoryIndex
INTEGER,
sleHistoryDataSource
OBJECT IDENTIFIER,
sleHistoryBucketsRequested
INTEGER,
sleHistoryBucketsGranted
INTEGER,
sleHistoryInterval
INTEGER,
sleHistoryOwner
OwnerString,
sleHistoryStatus
SleEntryStatus
}
-- 1.3.6.1.4.1.6296.101.9.1.1.1.1
-- 1.3.6.1.4.1.6296.101.9.1.1.1.1
sleHistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
historyControl table. Each such entry defines a
set of samples at a particular interval for an
interface on the device."
::= { sleHistoryEntry 1 }
-- 1.3.6.1.4.1.6296.101.9.1.1.1.2
-- 1.3.6.1.4.1.6296.101.9.1.1.1.2
sleHistoryDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the source of the data for
which historical data was collected and
placed in a media-specific table on behalf of this
historyControlEntry. This source can be any
interface on this device. In order to identify
a particular interface, this object shall identify
the instance of the ifIndex object, defined
in RFC 1213 and RFC 1573 [4,6], for the desired
interface. For example, if an entry were to receive
data from interface #1, this object would be set
to ifIndex.1.
The statistics in this group reflect all packets
on the local network segment attached to the
identified interface.
An agent may or may not be able to tell if fundamental
changes to the media of the interface have occurred
and necessitate an invalidation of this entry. For
example, a hot-pluggable ethernet card could be
pulled out and replaced by a token-ring card. In
such a case, if the agent has such knowledge of the
change, it is recommended that it invalidate this
entry.
This object may not be modified if the associated
historyControlStatus object is equal to valid(1)."
::= { sleHistoryEntry 2 }
-- 1.3.6.1.4.1.6296.101.9.1.1.1.3
-- 1.3.6.1.4.1.6296.101.9.1.1.1.3
sleHistoryBucketsRequested OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The requested number of discrete time intervals
over which data is to be saved in the part of the
media-specific table associated with this
historyControlEntry.
When this object is created or modified, the probe
should set historyControlBucketsGranted as closely to
this object as is possible for the particular probe
implementation and available resources."
DEFVAL { 50 }
::= { sleHistoryEntry 3 }
-- 1.3.6.1.4.1.6296.101.9.1.1.1.4
-- 1.3.6.1.4.1.6296.101.9.1.1.1.4
sleHistoryBucketsGranted OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of discrete sampling intervals
over which data shall be saved in the part of
the media-specific table associated with this
historyControlEntry.
When the associated historyControlBucketsRequested
object is created or modified, the probe
should set this object as closely to the requested
value as is possible for the particular
probe implementation and available resources. The
probe must not lower this value except as a result
of a modification to the associated
historyControlBucketsRequested object.
There will be times when the actual number of
buckets associated with this entry is less than
the value of this object. In this case, at the
end of each sampling interval, a new bucket will
be added to the media-specific table.
When the number of buckets reaches the value of
this object and a new bucket is to be added to the
media-specific table, the oldest bucket associated
with this historyControlEntry shall be deleted by
the agent so that the new bucket can be added.
When the value of this object changes to a value less
than the current value, entries are deleted
from the media-specific table associated with this
historyControlEntry. Enough of the oldest of these
entries shall be deleted by the agent so that their
number remains less than or equal to the new value of
this object.
When the value of this object changes to a value
greater than the current value, the number of
associated media- specific entries may be allowed to
grow."
::= { sleHistoryEntry 4 }
-- 1.3.6.1.4.1.6296.101.9.1.1.1.5
-- 1.3.6.1.4.1.6296.101.9.1.1.1.5
sleHistoryInterval OBJECT-TYPE
SYNTAX INTEGER (1..3600)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval in seconds over which the data is
sampled for each bucket in the part of the
media-specific table associated with this
historyControlEntry. This interval can
be set to any number of seconds between 1 and
3600 (1 hour).
Because the counters in a bucket may overflow at their
maximum value with no indication, a prudent manager
will take into account the possibility of overflow
in any of the associated counters. It is important
to consider the minimum time in which any counter
could overflow on a particular media type and set
the historyControlInterval object to a value less
than this interval. This is typically most
important for the 'octets' counter in any
media-specific table. For example, on an Ethernet
network, the etherHistoryOctets counter could
overflow in about one hour at the Ethernet's maximum
utilization.
This object may not be modified if the associated
historyControlStatus object is equal to valid(1)."
DEFVAL { 1800 }
::= { sleHistoryEntry 5 }
-- 1.3.6.1.4.1.6296.101.9.1.1.1.6
-- 1.3.6.1.4.1.6296.101.9.1.1.1.6
sleHistoryOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { sleHistoryEntry 6 }
-- 1.3.6.1.4.1.6296.101.9.1.1.1.7
-- 1.3.6.1.4.1.6296.101.9.1.1.1.7
sleHistoryStatus OBJECT-TYPE
SYNTAX SleEntryStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this historyControl entry.
Each instance of the media-specific table associated
with this historyControlEntry will be deleted by the
agent if this historyControlEntry is not equal to
valid(1)."
::= { sleHistoryEntry 7 }
-- 1.3.6.1.4.1.6296.101.9.1.2
-- 1.3.6.1.4.1.6296.101.9.1.2
sleHistoryControl OBJECT IDENTIFIER ::= { sleHistory 2 }
-- Node definitions
--
-- 1.3.6.1.4.1.6296.101.9.1.2.1
-- 1.3.6.1.4.1.6296.101.9.1.2.1
sleHistoryControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createHistory(1),
destroyHistory(2),
setHistoryProfile(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
createHistory:
sleHistoryControlIndex
sleHistoryControlDataSource
sleHistoryControlBucketsRequested
sleHistoryControlInterval
sleHistoryControlOwner
sleHistoryControlSts
destroyHistory:
sleHistoryControlIndex
setHistoryProfile:
sleHistoryControlIndex
sleHistoryControlDataSource
sleHistoryControlBucketsRequested
sleHistoryControlInterval
sleHistoryControlOwner
sleHistoryControlSts
"
::= { sleHistoryControl 1 }
-- 1.3.6.1.4.1.6296.101.9.1.2.2
-- 1.3.6.1.4.1.6296.101.9.1.2.2
sleHistoryControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a user command.
"
::= { sleHistoryControl 2 }
-- 1.3.6.1.4.1.6296.101.9.1.2.3
-- 1.3.6.1.4.1.6296.101.9.1.2.3
sleHistoryControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum wait time for the manager for a long running user command.
"
::= { sleHistoryControl 3 }
-- 1.3.6.1.4.1.6296.101.9.1.2.4
-- 1.3.6.1.4.1.6296.101.9.1.2.4
sleHistoryControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command (end of command)."
::= { sleHistoryControl 4 }
-- 1.3.6.1.4.1.6296.101.9.1.2.5
-- 1.3.6.1.4.1.6296.101.9.1.2.5
sleHistoryControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the last user command."
::= { sleHistoryControl 5 }
-- 1.3.6.1.4.1.6296.101.9.1.2.6
-- 1.3.6.1.4.1.6296.101.9.1.2.6
sleHistoryControlIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleHistoryControl 6 }
-- 1.3.6.1.4.1.6296.101.9.1.2.7
-- 1.3.6.1.4.1.6296.101.9.1.2.7
sleHistoryControlDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the source of the data for
which historical data was collected and
placed in a media-specific table on behalf of this
historyControlEntry. This source can be any
interface on this device. In order to identify
a particular interface, this object shall identify
the instance of the ifIndex object, defined
in RFC 1213 and RFC 1573 [4,6], for the desired
interface. For example, if an entry were to receive
data from interface #1, this object would be set
to ifIndex.1.
The statistics in this group reflect all packets
on the local network segment attached to the
identified interface.
An agent may or may not be able to tell if fundamental
changes to the media of the interface have occurred
and necessitate an invalidation of this entry. For
example, a hot-pluggable ethernet card could be
pulled out and replaced by a token-ring card. In
such a case, if the agent has such knowledge of the
change, it is recommended that it invalidate this
entry.
This object may not be modified if the associated
historyControlStatus object is equal to valid(1)."
::= { sleHistoryControl 7 }
-- 1.3.6.1.4.1.6296.101.9.1.2.8
-- 1.3.6.1.4.1.6296.101.9.1.2.8
sleHistoryControlBucketsRequested OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The requested number of discrete time intervals
over which data is to be saved in the part of the
media-specific table associated with this
historyControlEntry.
When this object is created or modified, the probe
should set historyControlBucketsGranted as closely to
this object as is possible for the particular probe
implementation and available resources."
DEFVAL { 50 }
::= { sleHistoryControl 8 }
-- 1.3.6.1.4.1.6296.101.9.1.2.9
-- 1.3.6.1.4.1.6296.101.9.1.2.9
sleHistoryControlInterval OBJECT-TYPE
SYNTAX INTEGER (1..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval in seconds over which the data is
sampled for each bucket in the part of the
media-specific table associated with this
historyControlEntry. This interval can
be set to any number of seconds between 1 and
3600 (1 hour).
Because the counters in a bucket may overflow at their
maximum value with no indication, a prudent manager
will take into account the possibility of overflow
in any of the associated counters. It is important
to consider the minimum time in which any counter
could overflow on a particular media type and set
the historyControlInterval object to a value less
than this interval. This is typically most
important for the 'octets' counter in any
media-specific table. For example, on an Ethernet
network, the etherHistoryOctets counter could
overflow in about one hour at the Ethernet's maximum
utilization.
This object may not be modified if the associated
historyControlStatus object is equal to valid(1)."
DEFVAL { 1800 }
::= { sleHistoryControl 9 }
-- 1.3.6.1.4.1.6296.101.9.1.2.10
-- 1.3.6.1.4.1.6296.101.9.1.2.10
sleHistoryControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { sleHistoryControl 10 }
-- 1.3.6.1.4.1.6296.101.9.1.2.11
-- 1.3.6.1.4.1.6296.101.9.1.2.11
sleHistoryControlSts OBJECT-TYPE
SYNTAX SleEntryStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this historyControl entry.
Each instance of the media-specific table associated
with this historyControlEntry will be deleted by the
agent if this historyControlEntry is not equal to
valid(1)."
::= { sleHistoryControl 11 }
-- 1.3.6.1.4.1.6296.101.9.1.3
-- 1.3.6.1.4.1.6296.101.9.1.3
sleHistoryNotification OBJECT IDENTIFIER ::= { sleHistory 3 }
-- 1.3.6.1.4.1.6296.101.9.1.3.1
-- 1.3.6.1.4.1.6296.101.9.1.3.1
sleHistoryCreated NOTIFICATION-TYPE
OBJECTS { sleHistoryDataSource, sleHistoryBucketsRequested, sleHistoryInterval, sleHistoryOwner, sleHistoryStatus,
sleHistoryControlRequest, sleHistoryControlTimeStamp, sleHistoryControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleHistoryNotification 1 }
-- 1.3.6.1.4.1.6296.101.9.1.3.2
-- 1.3.6.1.4.1.6296.101.9.1.3.2
sleHistoryDestroyed NOTIFICATION-TYPE
OBJECTS { sleHistoryIndex, sleHistoryControlRequest, sleHistoryControlTimeStamp, sleHistoryControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleHistoryNotification 2 }
-- 1.3.6.1.4.1.6296.101.9.1.3.3
-- 1.3.6.1.4.1.6296.101.9.1.3.3
sleHistoryProfileChanged NOTIFICATION-TYPE
OBJECTS { sleHistoryDataSource, sleHistoryBucketsRequested, sleHistoryInterval, sleHistoryOwner, sleHistoryStatus,
sleHistoryControlRequest, sleHistoryControlTimeStamp, sleHistoryControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleHistoryNotification 3 }
-- 1.3.6.1.4.1.6296.101.9.2
-- 1.3.6.1.4.1.6296.101.9.2
sleAlarm OBJECT IDENTIFIER ::= { sleRmon 2 }
-- The sleAlarm Group
-- Implementation of the Alarm group is optional.
--
-- The sleAlarm Group requires the implementation of the Event
-- group.
--
-- The sleAlarm group periodically takes
-- statistical samples from variables in the probe and
-- compares them to thresholds that have been
-- configured. The alarm table stores configuration
-- entries that each define a variable, polling period,
-- and threshold parameters. If a sample is found to
-- cross the threshold values, an event is generated.
-- Only variables that resolve to an ASN.1 primitive
-- type of INTEGER (INTEGER, Counter, Gauge, or
-- TimeTicks) may be monitored in this way.
--
-- This function has a hysteresis mechanism to limit
-- the generation of events. This mechanism generates
-- one event as a threshold is crossed in the
-- appropriate direction. No more events are generated
-- for that threshold until the opposite threshold is
-- crossed.
--
-- In the case of a sampling a deltaValue, a probe may
-- implement this mechanism with more precision if it
-- takes a delta sample twice per period, each time
-- comparing the sum of the latest two samples to the
-- threshold. This allows the detection of threshold
-- crossings that span the sampling boundary. Note
-- that this does not require any special configuration
-- of the threshold value. It is suggested that probes
-- implement this more precise algorithm.
-- 1.3.6.1.4.1.6296.101.9.2.1
-- 1.3.6.1.4.1.6296.101.9.2.1
sleAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of alarm entries."
::= { sleAlarm 1 }
-- 1.3.6.1.4.1.6296.101.9.2.1.1
-- 1.3.6.1.4.1.6296.101.9.2.1.1
sleAlarmEntry OBJECT-TYPE
SYNTAX SleAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of parameters that set up a periodic checking
for alarm conditions. For example, an instance of the
sleAlarmValue object might be named sleAlarmValue.8"
INDEX { sleAlarmIndex }
::= { sleAlarmTable 1 }
SleAlarmEntry ::=
SEQUENCE {
sleAlarmIndex
INTEGER,
sleAlarmInterval
Integer32,
sleAlarmVariable
OBJECT IDENTIFIER,
sleAlarmSampleType
INTEGER,
sleAlarmValue
Integer32,
sleAlarmStartupAlarm
INTEGER,
sleAlarmRisingThreshold
Integer32,
sleAlarmFallingThreshold
Integer32,
sleAlarmRisingEventIndex
INTEGER,
sleAlarmFallingEventIndex
INTEGER,
sleAlarmOwner
OwnerString,
sleAlarmStatus
SleEntryStatus
}
-- 1.3.6.1.4.1.6296.101.9.2.1.1.1
-- 1.3.6.1.4.1.6296.101.9.2.1.1.1
sleAlarmIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
alarm table. Each such entry defines a
diagnostic sample at a particular interval
for an object on the device."
::= { sleAlarmEntry 1 }
-- 1.3.6.1.4.1.6296.101.9.2.1.1.2
-- 1.3.6.1.4.1.6296.101.9.2.1.1.2
sleAlarmInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds. When setting this variable, care
should be taken in the case of deltaValue
sampling - the interval should be set short enough
that the sampled variable is very unlikely to
increase or decrease by more than 2^31 - 1 during
a single sampling interval.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { sleAlarmEntry 2 }
-- 1.3.6.1.4.1.6296.101.9.2.1.1.3
-- 1.3.6.1.4.1.6296.101.9.2.1.1.3
sleAlarmVariable OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object identifier of the particular variable to
be sampled. Only variables that resolve to an ASN.1
primitive type of INTEGER (INTEGER, Counter, Gauge,
or TimeTicks) may be sampled.
Because SNMP access control is articulated entirely
in terms of the contents of MIB views, no access
control mechanism exists that can restrict the value
of this object to identify only those objects that
exist in a particular MIB view. Because there is
thus no acceptable means of restricting the read
access that could be obtained through the alarm
mechanism, the probe must only grant write access to
this object in those views that have read access to
all objects on the probe.
During a set operation, if the supplied variable
name is not available in the selected MIB view, a
badValue error must be returned. If at any time the
variable name of an establisled alarmEntry is no
longer available in the selected MIB view, the probe
must change the status of this alarmEntry to
invalid(4).
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { sleAlarmEntry 3 }
-- 1.3.6.1.4.1.6296.101.9.2.1.1.4
-- 1.3.6.1.4.1.6296.101.9.2.1.1.4
sleAlarmSampleType OBJECT-TYPE
SYNTAX INTEGER
{
absoluteValue(1),
deltaValue(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The method of sampling the selected variable and
calculating the value to be compared against the
thresholds. If the value of this object is
absoluteValue(1), the value of the selected variable
will be compared directly with the thresholds at the
end of the sampling interval. If the value of this
object is deltaValue(2), the value of the selected
variable at the last sample will be subtracted from
the current value, and the difference compared with
the thresholds.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { sleAlarmEntry 4 }
-- 1.3.6.1.4.1.6296.101.9.2.1.1.5
-- 1.3.6.1.4.1.6296.101.9.2.1.1.5
sleAlarmValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the statistic during the last sampling
period. For example, if the sample type is
deltaValue, this value will be the difference
between the samples at the beginning and end of the
period. If the sample type is absoluteValue, this
value will be the sampled value at the end of the
period.
This is the value that is compared with the rising and
falling thresholds.
The value during the current sampling period is not
made available until the period is completed and will
remain available until the next period completes."
::= { sleAlarmEntry 5 }
-- 1.3.6.1.4.1.6296.101.9.2.1.1.6
-- 1.3.6.1.4.1.6296.101.9.2.1.1.6
sleAlarmStartupAlarm OBJECT-TYPE
SYNTAX INTEGER
{
risingAlarm(1),
fallingAlarm(2),
risingOrFallingAlarm(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm that may be sent when this entry is first
set to valid. If the first sample after this entry
becomes valid is greater than or equal to the
risingThreshold and alarmStartupAlarm is equal to
risingAlarm(1) or risingOrFallingAlarm(3), then a
single rising alarm will be generated. If the first
sample after this entry becomes valid is less than
or equal to the fallingThreshold and
alarmStartupAlarm is equal to fallingAlarm(2) or
risingOrFallingAlarm(3), then a single falling alarm
will be generated.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { sleAlarmEntry 6 }
-- 1.3.6.1.4.1.6296.101.9.2.1.1.7
-- 1.3.6.1.4.1.6296.101.9.2.1.1.7
sleAlarmRisingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A threshold for the sampled statistic. When the
current sampled value is greater than or equal to
this threshold, and the value at the last sampling
interval was less than this threshold, a single
event will be generated. A single event will also
be generated if the first sample after this entry
becomes valid is greater than or equal to this
threshold and the associated alarmStartupAlarm is
equal to risingAlarm(1) or risingOrFallingAlarm(3).
After a rising event is generated, another such event
will not be generated until the sampled value
falls below this threshold and reaches the
alarmFallingThreshold.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { sleAlarmEntry 7 }
-- 1.3.6.1.4.1.6296.101.9.2.1.1.8
-- 1.3.6.1.4.1.6296.101.9.2.1.1.8
sleAlarmFallingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A threshold for the sampled statistic. When the
current sampled value is less than or equal to this
threshold, and the value at the last sampling
interval was greater than this threshold, a single
event will be generated. A single event will also
be generated if the first sample after this entry
becomes valid is less than or equal to this
threshold and the associated alarmStartupAlarm is
equal to fallingAlarm(2) or risingOrFallingAlarm(3).
After a falling event is generated, another such event
will not be generated until the sampled value
rises above this threshold and reaches the
alarmRisingThreshold.
This object may not be modified if the associated
sleAlarmStatus object is equal to valid(1)."
::= { sleAlarmEntry 8 }
-- 1.3.6.1.4.1.6296.101.9.2.1.1.9
-- 1.3.6.1.4.1.6296.101.9.2.1.1.9
sleAlarmRisingEventIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the eventEntry that is
used when a rising threshold is crossed. The
eventEntry identified by a particular value of
this index is the same as identified by the same value
of the eventIndex object. If there is no
corresponding entry in the eventTable, then
no association exists. In particular, if this value
is zero, no associated event will be generated, as
zero is not a valid event index.
This object may not be modified if the associated
sleAlarmStatus object is equal to valid(1)."
::= { sleAlarmEntry 9 }
-- 1.3.6.1.4.1.6296.101.9.2.1.1.10
-- 1.3.6.1.4.1.6296.101.9.2.1.1.10
sleAlarmFallingEventIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the eventEntry that is
used when a falling threshold is crossed. The
eventEntry identified by a particular value of
this index is the same as identified by the same value
of the eventIndex object. If there is no
corresponding entry in the eventTable, then
no association exists. In particular, if this value
is zero, no associated event will be generated, as
zero is not a valid event index.
This object may not be modified if the associated
sleAlarmStatus object is equal to valid(1)."
::= { sleAlarmEntry 10 }
-- 1.3.6.1.4.1.6296.101.9.2.1.1.11
-- 1.3.6.1.4.1.6296.101.9.2.1.1.11
sleAlarmOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { sleAlarmEntry 11 }
-- 1.3.6.1.4.1.6296.101.9.2.1.1.12
-- 1.3.6.1.4.1.6296.101.9.2.1.1.12
sleAlarmStatus OBJECT-TYPE
SYNTAX SleEntryStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this alarm entry."
::= { sleAlarmEntry 12 }
-- 1.3.6.1.4.1.6296.101.9.2.2
-- 1.3.6.1.4.1.6296.101.9.2.2
sleAlarmControl OBJECT IDENTIFIER ::= { sleAlarm 2 }
-- Node definitions
--
-- 1.3.6.1.4.1.6296.101.9.2.2.1
-- 1.3.6.1.4.1.6296.101.9.2.2.1
sleAlarmControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createAlarm(1),
destroyAlarm(2),
setAlarmProfile(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
createAlarm:
(sleAlarmControlIndex)
sleAlarmInterval
sleAlarmControlVariable
sleAlarmControlSampleType
sleAlarmControlStartupAlarm
sleAlarmControlRisingThreshold
sleAlarmControlFallingThreshold
sleAlarmControlRisingEventIndex
sleAlarmControlFallingEventIndex
sleAlarmControlOwner
sleAlarmControlSts
destroyAlarm:
sleAlarmControlIndex
setAlarmProfile:
sleAlarmControlIndex
sleAlarmControlInterval
sleAlarmControlVariable
sleAlarmControlSampleType
sleAlarmControlStartupAlarm
sleAlarmControlRisingThreshold
sleAlarmControlFallingThreshold
sleAlarmControlRisingEventIndex
sleAlarmControlFallingEventIndex
sleAlarmControlOwner
sleAlarmControlSts
"
::= { sleAlarmControl 1 }
-- 1.3.6.1.4.1.6296.101.9.2.2.2
-- 1.3.6.1.4.1.6296.101.9.2.2.2
sleAlarmControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a user command.
"
::= { sleAlarmControl 2 }
-- 1.3.6.1.4.1.6296.101.9.2.2.3
-- 1.3.6.1.4.1.6296.101.9.2.2.3
sleAlarmControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum wait time for the manager for a long running user command.
"
::= { sleAlarmControl 3 }
-- 1.3.6.1.4.1.6296.101.9.2.2.4
-- 1.3.6.1.4.1.6296.101.9.2.2.4
sleAlarmControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command (end of command)."
::= { sleAlarmControl 4 }
-- 1.3.6.1.4.1.6296.101.9.2.2.5
-- 1.3.6.1.4.1.6296.101.9.2.2.5
sleAlarmControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the last user command."
::= { sleAlarmControl 5 }
-- 1.3.6.1.4.1.6296.101.9.2.2.6
-- 1.3.6.1.4.1.6296.101.9.2.2.6
sleAlarmControlIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmControl 6 }
-- 1.3.6.1.4.1.6296.101.9.2.2.7
-- 1.3.6.1.4.1.6296.101.9.2.2.7
sleAlarmControlInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds. When setting this variable, care
should be taken in the case of deltaValue
sampling - the interval should be set short enough
that the sampled variable is very unlikely to
increase or decrease by more than 2^31 - 1 during
a single sampling interval.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { sleAlarmControl 7 }
-- 1.3.6.1.4.1.6296.101.9.2.2.8
-- 1.3.6.1.4.1.6296.101.9.2.2.8
sleAlarmControlVariable OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object identifier of the particular variable to
be sampled. Only variables that resolve to an ASN.1
primitive type of INTEGER (INTEGER, Counter, Gauge,
or TimeTicks) may be sampled.
Because SNMP access control is articulated entirely
in terms of the contents of MIB views, no access
control mechanism exists that can restrict the value
of this object to identify only those objects that
exist in a particular MIB view. Because there is
thus no acceptable means of restricting the read
access that could be obtained through the alarm
mechanism, the probe must only grant write access to
this object in those views that have read access to
all objects on the probe.
During a set operation, if the supplied variable
name is not available in the selected MIB view, a
badValue error must be returned. If at any time the
variable name of an establisled alarmEntry is no
longer available in the selected MIB view, the probe
must change the status of this alarmEntry to
invalid(4).
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { sleAlarmControl 8 }
-- 1.3.6.1.4.1.6296.101.9.2.2.9
-- 1.3.6.1.4.1.6296.101.9.2.2.9
sleAlarmControlSampleType OBJECT-TYPE
SYNTAX INTEGER
{
absoluteValue(1),
deltaValue(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The method of sampling the selected variable and
calculating the value to be compared against the
thresholds. If the value of this object is
absoluteValue(1), the value of the selected variable
will be compared directly with the thresholds at the
end of the sampling interval. If the value of this
object is deltaValue(2), the value of the selected
variable at the last sample will be subtracted from
the current value, and the difference compared with
the thresholds.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { sleAlarmControl 9 }
-- 1.3.6.1.4.1.6296.101.9.2.2.10
-- 1.3.6.1.4.1.6296.101.9.2.2.10
sleAlarmControlStartupAlarm OBJECT-TYPE
SYNTAX INTEGER
{
risingAlarm(1),
fallingAlarm(2),
risingOrFallingAlarm(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The alarm that may be sent when this entry is first
set to valid. If the first sample after this entry
becomes valid is greater than or equal to the
risingThreshold and alarmStartupAlarm is equal to
risingAlarm(1) or risingOrFallingAlarm(3), then a
single rising alarm will be generated. If the first
sample after this entry becomes valid is less than
or equal to the fallingThreshold and
alarmStartupAlarm is equal to fallingAlarm(2) or
risingOrFallingAlarm(3), then a single falling alarm
will be generated.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { sleAlarmControl 10 }
-- 1.3.6.1.4.1.6296.101.9.2.2.11
-- 1.3.6.1.4.1.6296.101.9.2.2.11
sleAlarmControlRisingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A threshold for the sampled statistic. When the
current sampled value is greater than or equal to
this threshold, and the value at the last sampling
interval was less than this threshold, a single
event will be generated. A single event will also
be generated if the first sample after this entry
becomes valid is greater than or equal to this
threshold and the associated alarmStartupAlarm is
equal to risingAlarm(1) or risingOrFallingAlarm(3).
After a rising event is generated, another such event
will not be generated until the sampled value
falls below this threshold and reaches the
alarmFallingThreshold.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { sleAlarmControl 11 }
-- 1.3.6.1.4.1.6296.101.9.2.2.12
-- 1.3.6.1.4.1.6296.101.9.2.2.12
sleAlarmControlFallingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A threshold for the sampled statistic. When the
current sampled value is less than or equal to this
threshold, and the value at the last sampling
interval was greater than this threshold, a single
event will be generated. A single event will also
be generated if the first sample after this entry
becomes valid is less than or equal to this
threshold and the associated alarmStartupAlarm is
equal to fallingAlarm(2) or risingOrFallingAlarm(3).
After a falling event is generated, another such event
will not be generated until the sampled value
rises above this threshold and reaches the
alarmRisingThreshold.
This object may not be modified if the associated
sleAlarmStatus object is equal to valid(1)."
::= { sleAlarmControl 12 }
-- 1.3.6.1.4.1.6296.101.9.2.2.13
-- 1.3.6.1.4.1.6296.101.9.2.2.13
sleAlarmControlRisingEventIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The index of the eventEntry that is
used when a rising threshold is crossed. The
eventEntry identified by a particular value of
this index is the same as identified by the same value
of the eventIndex object. If there is no
corresponding entry in the eventTable, then
no association exists. In particular, if this value
is zero, no associated event will be generated, as
zero is not a valid event index.
This object may not be modified if the associated
sleAlarmStatus object is equal to valid(1)."
::= { sleAlarmControl 13 }
-- 1.3.6.1.4.1.6296.101.9.2.2.14
-- 1.3.6.1.4.1.6296.101.9.2.2.14
sleAlarmControlFallingEventIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The index of the eventEntry that is
used when a falling threshold is crossed. The
eventEntry identified by a particular value of
this index is the same as identified by the same value
of the eventIndex object. If there is no
corresponding entry in the eventTable, then
no association exists. In particular, if this value
is zero, no associated event will be generated, as
zero is not a valid event index.
This object may not be modified if the associated
sleAlarmStatus object is equal to valid(1)."
::= { sleAlarmControl 14 }
-- 1.3.6.1.4.1.6296.101.9.2.2.15
-- 1.3.6.1.4.1.6296.101.9.2.2.15
sleAlarmControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it."
::= { sleAlarmControl 15 }
-- 1.3.6.1.4.1.6296.101.9.2.2.16
-- 1.3.6.1.4.1.6296.101.9.2.2.16
sleAlarmControlSts OBJECT-TYPE
SYNTAX SleEntryStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this alarm entry."
::= { sleAlarmControl 16 }
-- 1.3.6.1.4.1.6296.101.9.2.3
-- 1.3.6.1.4.1.6296.101.9.2.3
sleAlarmNotification OBJECT IDENTIFIER ::= { sleAlarm 3 }
-- 1.3.6.1.4.1.6296.101.9.2.3.1
-- 1.3.6.1.4.1.6296.101.9.2.3.1
sleAlarmCreated NOTIFICATION-TYPE
OBJECTS { sleAlarmInterval, sleAlarmVariable, sleAlarmSampleType, sleAlarmStartupAlarm, sleAlarmRisingThreshold,
sleAlarmFallingThreshold, sleAlarmRisingEventIndex, sleAlarmFallingEventIndex, sleAlarmOwner, sleAlarmStatus,
sleAlarmControlRequest, sleAlarmControlTimeStamp, sleAlarmControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmNotification 1 }
-- 1.3.6.1.4.1.6296.101.9.2.3.2
-- 1.3.6.1.4.1.6296.101.9.2.3.2
sleAlarmDestroyed NOTIFICATION-TYPE
OBJECTS { sleAlarmIndex, sleAlarmControlRequest, sleAlarmControlTimeStamp, sleAlarmControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmNotification 2 }
-- 1.3.6.1.4.1.6296.101.9.2.3.3
-- 1.3.6.1.4.1.6296.101.9.2.3.3
sleAlarmProfileChanged NOTIFICATION-TYPE
OBJECTS { sleAlarmControlRequest, sleAlarmControlTimeStamp, sleAlarmControlReqResult, sleAlarmInterval, sleAlarmVariable,
sleAlarmSampleType, sleAlarmStartupAlarm, sleAlarmRisingThreshold, sleAlarmFallingThreshold, sleAlarmRisingEventIndex,
sleAlarmFallingEventIndex, sleAlarmOwner, sleAlarmStatus }
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmNotification 3 }
-- The status of a table entry.
--
-- Setting this object to the value invalid(4) has the
-- effect of invalidating the corresponding entry.
-- That is, it effectively disassociates the mapping
-- identified with said entry.
-- It is an implementation-specific matter as to whether
-- the agent removes an invalidated entry from the table.
-- Accordingly, management stations must be prepared to
-- receive tabular information from agents that
-- corresponds to entries currently not in use. Proper
-- interpretation of such entries requires examination
-- of the relevant EntryStatus object.
--
-- An existing instance of this object cannot be set to
-- createRequest(2). This object may only be set to
-- createRequest(2) when this instance is created. When
-- this object is created, the agent may wish to create
-- supplemental object instances with default values
-- to complete a conceptual row in this table. Because
-- the creation of these default objects is entirely at
-- the option of the agent, the manager must not assume
-- that any will be created, but may make use of any that
-- are created. Immediately after completing the create
-- operation, the agent must set this object to
-- underCreation(3).
--
-- When in the underCreation(3) state, an entry is
-- allowed to exist in a possibly incomplete, possibly
-- inconsistent state, usually to allow it to be
-- modified in mutiple PDUs. When in this state, an
-- entry is not fully active. Entries shall exist in
-- the underCreation(3) state until the management
-- station is finisled configuring the entry and sets
-- this object to valid(1) or aborts, setting this
-- object to invalid(4). If the agent determines that
-- an entry has been in the underCreation(3) state for
-- an abnormally long time, it may decide that the
-- management station has crasled. If the agent makes
-- this decision, it may set this object to invalid(4)
-- to reclaim the entry. A prudent agent will
-- understand that the management station may need to
-- wait for human input and will allow for that
-- possibility in its determination of this abnormally
-- long period.
--
-- An entry in the valid(1) state is fully configured and
-- consistent and fully represents the configuration or
-- operation such a row is intended to represent. For
-- example, it could be a statistical function that is
-- configured and active, or a filter that is available
-- in the list of filters processed by the packet capture
-- process.
--
-- A manager is restricted to changing the state of an
-- entry in the following ways:
--
-- create under
-- To: valid Request Creation invalid
-- From:
-- valid OK NO OK OK
-- createRequest N/A N/A N/A N/A
-- underCreation OK NO OK OK
-- invalid NO NO NO OK
-- nonExistent NO OK NO OK
--
-- In the table above, it is not applicable to move the
-- state from the createRequest state to any other
-- state because the manager will never find the
-- variable in that state. The nonExistent state is
-- not a value of the enumeration, rather it means that
-- the entryStatus variable does not exist at all.
--
-- An agent may allow an entryStatus variable to change
-- state in additional ways, so long as the semantics
-- of the states are followed. This allowance is made
-- to ease the implementation of the agent and is made
-- despite the fact that managers should never
-- excercise these additional state transitions.
-- 1.3.6.1.4.1.6296.101.9.3
-- 1.3.6.1.4.1.6296.101.9.3
sleEvent OBJECT IDENTIFIER ::= { sleRmon 3 }
-- The sleEvent Group
-- Implementation of the Event group is optional.
--
-- The Event group controls the generation and notification
-- of events from this device. Each entry in the eventTable
-- describes the parameters of the event that can be
-- triggered. Each event entry is fired by an associated
-- condition located elsewhere in the MIB. An event entry
-- may also be associated- with a function elsewhere in the
-- MIB that will be executed when the event is generated. For
-- example, a channel may be turned on or off by the firing
-- of an event.
--
-- Each eventEntry may optionally specify that a log entry
-- be created on its behalf whenever the event occurs.
-- Each entry may also specify that notification should
-- occur by way of SNMP trap messages. In this case, the
-- community for the trap message is given in the associated
-- eventCommunity object. The enterprise and specific trap
-- fields of the trap are determined by the condition that
-- triggered the event. Two traps are defined: risingAlarm
-- and fallingAlarm. If the eventTable is triggered by a
-- condition specified elsewhere, the enterprise and
-- specific trap fields must be specified for traps
-- generated for that condition.
-- 1.3.6.1.4.1.6296.101.9.3.1
-- 1.3.6.1.4.1.6296.101.9.3.1
sleEventTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of events to be generated."
::= { sleEvent 1 }
-- 1.3.6.1.4.1.6296.101.9.3.1.1
-- 1.3.6.1.4.1.6296.101.9.3.1.1
sleEventEntry OBJECT-TYPE
SYNTAX SleEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters that describe an event to be
generated when certain conditions are met. As an
example, an instance of the sleEventLastTimeSent object
might be named sleEventLastTimeSent.6"
INDEX { sleEventIndex }
::= { sleEventTable 1 }
SleEventEntry ::=
SEQUENCE {
sleEventIndex
INTEGER,
sleEventDescription
DisplayString,
sleEventType
INTEGER,
sleEventCommunity
OCTET STRING,
sleEventLastTimeSent
TimeTicks,
sleEventOwner
OwnerString,
sleEventStatus
SleEntryStatus
}
-- 1.3.6.1.4.1.6296.101.9.3.1.1.1
-- 1.3.6.1.4.1.6296.101.9.3.1.1.1
sleEventIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
event table. Each such entry defines one event that
is to be generated when the appropriate conditions
occur."
::= { sleEventEntry 1 }
-- 1.3.6.1.4.1.6296.101.9.3.1.1.2
-- 1.3.6.1.4.1.6296.101.9.3.1.1.2
sleEventDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A comment describing this event entry."
::= { sleEventEntry 2 }
-- send an SNMP trap
-- 1.3.6.1.4.1.6296.101.9.3.1.1.3
-- 1.3.6.1.4.1.6296.101.9.3.1.1.3
sleEventType OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
log(2),
snmpTrap(3),
logAndTrap(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of notification that the probe will make
about this event. In the case of log, an entry is
made in the log table for each event. In the case of
snmp-trap, an SNMP trap is sent to one or more
management stations."
::= { sleEventEntry 3 }
-- 1.3.6.1.4.1.6296.101.9.3.1.1.4
-- 1.3.6.1.4.1.6296.101.9.3.1.1.4
sleEventCommunity OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If an SNMP trap is to be sent, it will be sent to
the SNMP community specified by this octet string.
In the future this table will be extended to include
the party security mechanism. This object shall be
set to a string of length zero if it is intended that
that mechanism be used to specify the destination of
the trap."
::= { sleEventEntry 4 }
-- 1.3.6.1.4.1.6296.101.9.3.1.1.5
-- 1.3.6.1.4.1.6296.101.9.3.1.1.5
sleEventLastTimeSent OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time this event
entry last generated an event. If this entry has
not generated any events, this value will be
zero."
::= { sleEventEntry 5 }
-- 1.3.6.1.4.1.6296.101.9.3.1.1.6
-- 1.3.6.1.4.1.6296.101.9.3.1.1.6
sleEventOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it.
If this object contains a string starting with
'monitor' and has associated entries in the log
table, all connected management stations should
retrieve those log entries, as they may have
significance to all management stations connected to
this device"
::= { sleEventEntry 6 }
-- 1.3.6.1.4.1.6296.101.9.3.1.1.7
-- 1.3.6.1.4.1.6296.101.9.3.1.1.7
sleEventStatus OBJECT-TYPE
SYNTAX SleEntryStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this event entry.
If this object is not equal to valid(1), all
associated log entries shall be deleted by the
agent."
::= { sleEventEntry 7 }
-- 1.3.6.1.4.1.6296.101.9.3.2
-- 1.3.6.1.4.1.6296.101.9.3.2
sleEventControl OBJECT IDENTIFIER ::= { sleEvent 2 }
-- Node definitions
--
-- 1.3.6.1.4.1.6296.101.9.3.2.1
-- 1.3.6.1.4.1.6296.101.9.3.2.1
sleEventControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createEvent(1),
destroyEvent(2),
setEventProfile(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
createEvent:
(sleEventControlIndex)
sleEventControlDescription
sleEventControlType
sleEventControlCommunity
sleEventControlOwner
sleEventControlSts
destroyEvent:
sleEventControlIndex
setEventProfile:
sleEventControlIndex
sleEventControlDescription
sleEventControlType
sleEventControlCommunity
sleEventControlOwner
sleEventControlSts
"
::= { sleEventControl 1 }
-- 1.3.6.1.4.1.6296.101.9.3.2.2
-- 1.3.6.1.4.1.6296.101.9.3.2.2
sleEventControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a user command.
"
::= { sleEventControl 2 }
-- 1.3.6.1.4.1.6296.101.9.3.2.3
-- 1.3.6.1.4.1.6296.101.9.3.2.3
sleEventControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum wait time for the manager for a long running user command.
"
::= { sleEventControl 3 }
-- 1.3.6.1.4.1.6296.101.9.3.2.4
-- 1.3.6.1.4.1.6296.101.9.3.2.4
sleEventControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command (end of command)."
::= { sleEventControl 4 }
-- 1.3.6.1.4.1.6296.101.9.3.2.5
-- 1.3.6.1.4.1.6296.101.9.3.2.5
sleEventControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the last user command."
::= { sleEventControl 5 }
-- 1.3.6.1.4.1.6296.101.9.3.2.6
-- 1.3.6.1.4.1.6296.101.9.3.2.6
sleEventControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEventControl 6 }
-- 1.3.6.1.4.1.6296.101.9.3.2.7
-- 1.3.6.1.4.1.6296.101.9.3.2.7
sleEventControlDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A comment describing this event entry."
::= { sleEventControl 7 }
-- send an SNMP trap
-- 1.3.6.1.4.1.6296.101.9.3.2.8
-- 1.3.6.1.4.1.6296.101.9.3.2.8
sleEventControlType OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
log(2),
snmpTrap(3),
logAndTrap(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of notification that the probe will make
about this event. In the case of log, an entry is
made in the log table for each event. In the case of
snmp-trap, an SNMP trap is sent to one or more
management stations."
::= { sleEventControl 8 }
-- 1.3.6.1.4.1.6296.101.9.3.2.9
-- 1.3.6.1.4.1.6296.101.9.3.2.9
sleEventControlCommunity OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If an SNMP trap is to be sent, it will be sent to
the SNMP community specified by this octet string.
In the future this table will be extended to include
the party security mechanism. This object shall be
set to a string of length zero if it is intended that
that mechanism be used to specify the destination of
the trap."
::= { sleEventControl 9 }
-- 1.3.6.1.4.1.6296.101.9.3.2.10
-- 1.3.6.1.4.1.6296.101.9.3.2.10
sleEventControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it.
If this object contains a string starting with
'monitor' and has associated entries in the log
table, all connected management stations should
retrieve those log entries, as they may have
significance to all management stations connected to
this device"
::= { sleEventControl 10 }
-- 1.3.6.1.4.1.6296.101.9.3.2.11
-- 1.3.6.1.4.1.6296.101.9.3.2.11
sleEventControlSts OBJECT-TYPE
SYNTAX SleEntryStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this event entry.
If this object is not equal to valid(1), all
associated log entries shall be deleted by the
agent."
::= { sleEventControl 11 }
-- 1.3.6.1.4.1.6296.101.9.3.3
-- 1.3.6.1.4.1.6296.101.9.3.3
sleEventNotification OBJECT IDENTIFIER ::= { sleEvent 3 }
-- 1.3.6.1.4.1.6296.101.9.3.3.1
-- 1.3.6.1.4.1.6296.101.9.3.3.1
sleEventCreated NOTIFICATION-TYPE
OBJECTS { sleEventDescription, sleEventType, sleEventCommunity, sleEventOwner, sleEventStatus,
sleEventControlRequest, sleEventControlTimeStamp, sleEventControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleEventNotification 1 }
-- 1.3.6.1.4.1.6296.101.9.3.3.2
-- 1.3.6.1.4.1.6296.101.9.3.3.2
sleEventDestroyed NOTIFICATION-TYPE
OBJECTS { sleEventIndex, sleEventControlRequest, sleEventControlTimeStamp, sleEventControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleEventNotification 2 }
-- 1.3.6.1.4.1.6296.101.9.3.3.3
-- 1.3.6.1.4.1.6296.101.9.3.3.3
sleEventProfileChanged NOTIFICATION-TYPE
OBJECTS { sleEventDescription, sleEventType, sleEventCommunity, sleEventOwner, sleEventStatus,
sleEventControlRequest, sleEventControlTimeStamp, sleEventControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleEventNotification 3 }
-- 1.3.6.1.4.1.6296.101.9.4
-- 1.3.6.1.4.1.6296.101.9.4
sleStatistics OBJECT IDENTIFIER ::= { sleRmon 4 }
-- 1.3.6.1.4.1.6296.101.9.4.1
-- 1.3.6.1.4.1.6296.101.9.4.1
sleEtherStats OBJECT IDENTIFIER ::= { sleStatistics 1 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1
-- 1.3.6.1.4.1.6296.101.9.4.1.1
sleEtherStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleEtherStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleEtherStats 1 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1
sleEtherStatsEntry OBJECT-TYPE
SYNTAX SleEtherStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleEtherStatsIndex }
::= { sleEtherStatsTable 1 }
SleEtherStatsEntry ::=
SEQUENCE {
sleEtherStatsIndex
INTEGER,
sleEtherStatsDataSource
OBJECT IDENTIFIER,
sleEtherStatsDropEvents
Counter32,
sleEtherStatsOctets
Counter32,
sleEtherStatsPkts
Counter32,
sleEtherStatsBroadcastPkts
Counter32,
sleEtherStatsMulticastPkts
Counter32,
sleEtherStatsCRCAlignErrors
Counter32,
sleEtherStatsUndersizePkts
Counter32,
sleEtherStatsOversizePkts
Counter32,
sleEtherStatsFragments
Counter32,
sleEtherStatsJabbers
Counter32,
sleEtherStatsCollisions
Counter32,
sleEtherStatsPkts64Octets
Counter32,
sleEtherStatsPkts65to127Octets
Counter32,
sleEtherStatsPkts128to255Octets
Counter32,
sleEtherStatsPkts256to511Octets
Counter32,
sleEtherStatsPkts512to1023Octets
Counter32,
sleEtherStatsPkts1024to1518Octets
Counter32,
sleEtherStatsOwner
OCTET STRING,
sleEtherStatsStatus
SleEntryStatus,
sleEtherStatsClearedTime
TimeTicks
}
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.1
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.1
sleEtherStatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this sleEtherStats entry"
::= { sleEtherStatsEntry 1 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.2
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.2
sleEtherStatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the source of the data that
this sleEtherStats entry is configured to analyze. This
source can be any ethernet interface on this device.
In order to identify a particular interface, this
object shall identify the instance of the ifIndex
object, defined in RFC 1213 and RFC 1573 [4,6], for
the desired interface. For example, if an entry
were to receive data from interface #1, this object
would be set to ifIndex.1.
The statistics in this group reflect all packets
on the local network segment attached to the
identified interface.
An agent may or may not be able to tell if
fundamental changes to the media of the interface
have occurred and necessitate an invalidation of
this entry. For example, a hot-pluggable ethernet
card could be pulled out and replaced by a
token-ring card. In such a case, if the agent has
such knowledge of the change, it is recommended that
it invalidate this entry.
This object may not be modified if the associated
sleEtherStatsStatus object is equal to valid(1)."
::= { sleEtherStatsEntry 2 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.3
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.3
sleEtherStatsDropEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which packets
were dropped by the probe due to lack of resources.
Note that this number is not necessarily the number of
packets dropped; it is just the number of times this
condition has been detected."
::= { sleEtherStatsEntry 3 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.4
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.4
sleEtherStatsOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets of data (including
those in bad packets) received on the
network (excluding framing bits but including
FCS octets).
This object can be used as a reasonable estimate of
ethernet utilization. If greater precision is
desired, the etherStatsPkts and etherStatsOctets
objects should be sampled before and after a common
interval. The differences in the sampled values are
Pkts and Octets, respectively, and the number of
seconds in the interval is Interval. These values
are used to calculate the Utilization as follows:
Pkts * (9.6 + 6.4) + (Octets * .8)
Utilization = -------------------------------------
Interval * 10,000
The result of this equation is the value Utilization
which is the percent utilization of the ethernet
segment on a scale of 0 to 100 percent.
"
::= { sleEtherStatsEntry 4 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.5
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.5
sleEtherStatsPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad packets,
broadcast packets, and multicast packets) received."
::= { sleEtherStatsEntry 5 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.6
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.6
sleEtherStatsBroadcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of good packets received that were
directed to the broadcast address. Note that this
does not include multicast packets."
::= { sleEtherStatsEntry 6 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.7
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.7
sleEtherStatsMulticastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of good packets received that were
directed to a multicast address. Note that this
number does not include packets directed to the
broadcast address.
"
::= { sleEtherStatsEntry 7 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.8
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.8
sleEtherStatsCRCAlignErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that
had a length (excluding framing bits, but
including FCS octets) of between 64 and 1518
octets, inclusive, but but had either a bad
Frame Check Sequence (FCS) with an integral
number of octets (FCS Error) or a bad FCS with
a non-integral number of octets (Alignment Error).
"
::= { sleEtherStatsEntry 8 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.9
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.9
sleEtherStatsUndersizePkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
less than 64 octets long (excluding framing bits,
but including FCS octets) and were otherwise well
formed.
"
::= { sleEtherStatsEntry 9 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.10
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.10
sleEtherStatsOversizePkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets) and were otherwise
well formed.
"
::= { sleEtherStatsEntry 10 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.11
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.11
sleEtherStatsFragments OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were less
than 64 octets in length (excluding framing bits but
including FCS octets) and had either a bad Frame
Check Sequence (FCS) with an integral number of
octets (FCS Error) or a bad FCS with a non-integral
number of octets (Alignment Error).
"
::= { sleEtherStatsEntry 11 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.12
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.12
sleEtherStatsJabbers OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets), and had either a bad
Frame Check Sequence (FCS) with an integral number
of octets (FCS Error) or a bad FCS with a
non-integral number of octets (Alignment Error).
"
::= { sleEtherStatsEntry 12 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.13
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.13
sleEtherStatsCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimate of the total number of collisions
on this Ethernet segment.
The value returned will depend on the location of
the RMON probe. Section 8.2.1.3 (10BASE-5) and
section 10.3.1.3 (10BASE-2) of IEEE standard 802.3
states that a station must detect a collision, in
the receive mode, if three or more stations are
transmitting simultaneously. A repeater port must
detect a collision when two or more stations are
transmitting simultaneously. Thus a probe placed on
a repeater port could record more collisions than a
probe connected to a station on the same segment
would.
Probe location plays a much smaller role when
considering 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE
standard 802.3 defines a collision as the
simultaneous presence of signals on the DO and RD
circuits (transmitting and receiving at the same
time). A 10BASE-T station can only detect
collisions when it is transmitting. Thus probes
placed on a station and a repeater, should report
the same number of collisions.
Note also that an RMON probe inside a repeater
should ideally report collisions between the
repeater and one or more other hosts (transmit
collisions as defined by IEEE 802.3k) plus receiver
collisions observed on any coax segments to which
the repeater is connected.
"
::= { sleEtherStatsEntry 13 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.14
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.14
sleEtherStatsPkts64Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were 64 octets in length
(excluding framing bits but including FCS octets).
"
::= { sleEtherStatsEntry 14 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.15
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.15
sleEtherStatsPkts65to127Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
65 and 127 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { sleEtherStatsEntry 15 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.16
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.16
sleEtherStatsPkts128to255Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
128 and 255 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { sleEtherStatsEntry 16 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.17
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.17
sleEtherStatsPkts256to511Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
256 and 511 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { sleEtherStatsEntry 17 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.18
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.18
sleEtherStatsPkts512to1023Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
512 and 1023 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { sleEtherStatsEntry 18 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.19
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.19
sleEtherStatsPkts1024to1518Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
1024 and 1518 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { sleEtherStatsEntry 19 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.20
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.20
sleEtherStatsOwner OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entity that configured this entry and is
therefore using the resources assigned to it.
"
::= { sleEtherStatsEntry 20 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.21
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.21
sleEtherStatsStatus OBJECT-TYPE
SYNTAX SleEntryStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this etherStats entry.
"
::= { sleEtherStatsEntry 21 }
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.22
-- 1.3.6.1.4.1.6296.101.9.4.1.1.1.22
sleEtherStatsClearedTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEtherStatsEntry 22 }
-- 1.3.6.1.4.1.6296.101.9.3.2
-- 1.3.6.1.4.1.6296.101.9.4.1.2
sleEtherStatsControl OBJECT IDENTIFIER ::= { sleEtherStats 2 }
-- Node definitions
--
-- 1.3.6.1.4.1.6296.101.9.3.2.1
-- 1.3.6.1.4.1.6296.101.9.4.1.2.1
sleEtherStatsControlRequest OBJECT-TYPE
SYNTAX INTEGER { clearRmonStat(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
createEvent:
(sleEventControlIndex)
sleEventControlDescription
sleEventControlType
sleEventControlCommunity
sleEventControlOwner
sleEventControlSts
destroyEvent:
sleEventControlIndex
setEventProfile:
sleEventControlIndex
sleEventControlDescription
sleEventControlType
sleEventControlCommunity
sleEventControlOwner
sleEventControlSts
"
::= { sleEtherStatsControl 1 }
-- 1.3.6.1.4.1.6296.101.9.3.2.2
-- 1.3.6.1.4.1.6296.101.9.4.1.2.2
sleEtherStatsControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a user command.
"
::= { sleEtherStatsControl 2 }
-- 1.3.6.1.4.1.6296.101.9.3.2.3
-- 1.3.6.1.4.1.6296.101.9.4.1.2.3
sleEtherStatsControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum wait time for the manager for a long running user command.
"
::= { sleEtherStatsControl 3 }
-- 1.3.6.1.4.1.6296.101.9.3.2.4
-- 1.3.6.1.4.1.6296.101.9.4.1.2.4
sleEtherStatsControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command (end of command)."
::= { sleEtherStatsControl 4 }
-- 1.3.6.1.4.1.6296.101.9.3.2.5
-- 1.3.6.1.4.1.6296.101.9.4.1.2.5
sleEtherStatsControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the last user command."
::= { sleEtherStatsControl 5 }
-- 1.3.6.1.4.1.6296.101.9.3.2.6
-- 1.3.6.1.4.1.6296.101.9.4.1.2.6
sleEtherStatsControlIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEtherStatsControl 6 }
-- 1.3.6.1.4.1.6296.101.9.5
sleRmonSimple OBJECT IDENTIFIER ::= { sleRmon 5 }
-- 1.3.6.1.4.1.6296.101.9.5.1
sleRmonSimpleTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleRmonSimpleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleRmonSimple 1 }
-- 1.3.6.1.4.1.6296.101.9.5.1.1
sleRmonSimpleEntry OBJECT-TYPE
SYNTAX SleRmonSimpleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleRmonSimplePortIndex, sleRmonSimpleSampleVariable }
::= { sleRmonSimpleTable 1 }
SleRmonSimpleEntry ::=
SEQUENCE {
sleRmonSimplePortIndex
Integer32,
sleRmonSimpleSampleVariable
INTEGER,
sleRmonSimpleSampleInterval
Integer32,
sleRmonSimpleRisingThreshold
Integer32,
sleRmonSimpleFallingThreshold
Integer32
}
-- 1.3.6.1.4.1.6296.101.9.5.1.1.1
sleRmonSimplePortIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port index."
::= { sleRmonSimpleEntry 1 }
-- 1.3.6.1.4.1.6296.101.9.5.1.1.2
sleRmonSimpleSampleVariable OBJECT-TYPE
SYNTAX INTEGER
{
crcAlignError(1),
jabber(2),
oversizePackets(3),
undersizePackets(4),
fragments(5),
dropEvents(6),
collisions(7),
ifInDiscards(8),
ifInErrors(9),
ifOutDiscards(10),
ifOutErrors(11),
ifInPauseFrame(12),
ifOutPauseFrame(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sample variable type."
::= { sleRmonSimpleEntry 2 }
-- 1.3.6.1.4.1.6296.101.9.5.1.1.3
sleRmonSimpleSampleInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sample interval. (10: minimum)"
::= { sleRmonSimpleEntry 3 }
-- 1.3.6.1.4.1.6296.101.9.5.1.1.4
sleRmonSimpleRisingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The rising threshold."
::= { sleRmonSimpleEntry 4 }
-- 1.3.6.1.4.1.6296.101.9.5.1.1.5
sleRmonSimpleFallingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The falling threshold."
::= { sleRmonSimpleEntry 5 }
-- 1.3.6.1.4.1.6296.101.9.3.2
-- 1.3.6.1.4.1.6296.101.9.5.2
sleRmonSimpleControl OBJECT IDENTIFIER ::= { sleRmonSimple 2 }
-- Node definitions
--
-- 1.3.6.1.4.1.6296.101.9.3.2.1
-- 1.3.6.1.4.1.6296.101.9.5.2.1
sleRmonSimpleControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createRmonSimple(1),
delRmonSimple(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description"
::= { sleRmonSimpleControl 1 }
-- 1.3.6.1.4.1.6296.101.9.3.2.2
-- 1.3.6.1.4.1.6296.101.9.5.2.2
sleRmonSimpleControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a user command.
"
::= { sleRmonSimpleControl 2 }
-- 1.3.6.1.4.1.6296.101.9.3.2.3
-- 1.3.6.1.4.1.6296.101.9.5.2.3
sleRmonSimpleControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum wait time for the manager for a long running user command.
"
::= { sleRmonSimpleControl 3 }
-- 1.3.6.1.4.1.6296.101.9.3.2.4
-- 1.3.6.1.4.1.6296.101.9.5.2.4
sleRmonSimpleControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command (end of command)."
::= { sleRmonSimpleControl 4 }
-- 1.3.6.1.4.1.6296.101.9.3.2.5
-- 1.3.6.1.4.1.6296.101.9.5.2.5
sleRmonSimpleControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the last user command."
::= { sleRmonSimpleControl 5 }
-- 1.3.6.1.4.1.6296.101.9.3.2.6
-- 1.3.6.1.4.1.6296.101.9.5.2.6
sleRmonSimpleControlPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port index."
::= { sleRmonSimpleControl 6 }
-- 1.3.6.1.4.1.6296.101.9.3.2.7
-- 1.3.6.1.4.1.6296.101.9.5.2.7
sleRmonSimpleControlSampleVariable OBJECT-TYPE
SYNTAX INTEGER
{
crcAlignError(1),
jabber(2),
oversizePackets(3),
undersizePackets(4),
fragments(5),
dropEvents(6),
collisions(7),
ifInDiscards(8),
ifInErrors(9),
ifOutDiscards(10),
ifOutErrors(11),
ifInPauseFrame(12),
ifOutPauseFrame(13),
allTypes(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The sample variable type. (255: set all sample variable types)"
::= { sleRmonSimpleControl 7 }
-- 1.3.6.1.4.1.6296.101.9.5.2.8
sleRmonSimpleControlSampleInterval OBJECT-TYPE
SYNTAX Integer32 (10..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The sample interval.(10: minimum)"
::= { sleRmonSimpleControl 8 }
-- send an SNMP trap
-- 1.3.6.1.4.1.6296.101.9.3.2.8
-- 1.3.6.1.4.1.6296.101.9.5.2.9
sleRmonSimpleControlRisingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The rising threshold."
::= { sleRmonSimpleControl 9 }
-- 1.3.6.1.4.1.6296.101.9.3.2.9
-- 1.3.6.1.4.1.6296.101.9.5.2.10
sleRmonSimpleControlFallingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The falling threshold."
::= { sleRmonSimpleControl 10 }
-- 1.3.6.1.4.1.6296.101.9.5.3
sleRmonSimpleNotification OBJECT IDENTIFIER ::= { sleRmonSimple 3 }
-- 1.3.6.1.4.1.6296.101.9.5.3.1
sleRmonSimpleCreated NOTIFICATION-TYPE
OBJECTS { sleRmonSimpleControlRequest, sleRmonSimpleControlTimeStamp, sleRmonSimpleControlReqResult, sleRmonSimpleControlPortIndex, sleRmonSimpleControlSampleVariable,
sleRmonSimpleControlSampleInterval, sleRmonSimpleControlRisingThreshold, sleRmonSimpleControlFallingThreshold }
STATUS current
DESCRIPTION
"createRmonSimple"
::= { sleRmonSimpleNotification 1 }
-- 1.3.6.1.4.1.6296.101.9.5.3.2
sleRmonSimpleDeleted NOTIFICATION-TYPE
OBJECTS { sleRmonSimpleControlRequest, sleRmonSimpleControlTimeStamp, sleRmonSimpleControlReqResult, sleRmonSimpleControlPortIndex, sleRmonSimpleControlSampleVariable
}
STATUS current
DESCRIPTION
"delRmonSimple"
::= { sleRmonSimpleNotification 2 }
-- 1.3.6.1.4.1.6296.101.9.6
sleRmonSimpleQueue OBJECT IDENTIFIER ::= { sleRmon 6 }
-- 1.3.6.1.4.1.6296.101.9.6.1
sleRmonSimpleQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleRmonSimpleQueueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleRmonSimpleQueue 1 }
-- 1.3.6.1.4.1.6296.101.9.6.1.1
sleRmonSimpleQueueEntry OBJECT-TYPE
SYNTAX SleRmonSimpleQueueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleRmonSimpleQueuePortIndex, sleRmonSimpleQueueSampleVariable, sleRmonSimpleQueueQueueNumber }
::= { sleRmonSimpleQueueTable 1 }
SleRmonSimpleQueueEntry ::=
SEQUENCE {
sleRmonSimpleQueuePortIndex
Integer32,
sleRmonSimpleQueueSampleVariable
INTEGER,
sleRmonSimpleQueueQueueNumber
Integer32,
sleRmonSimpleQueueSampleInterval
Integer32,
sleRmonSimpleQueueRisingThreshold
Integer32,
sleRmonSimpleQueueFallingThreshold
Integer32
}
-- 1.3.6.1.4.1.6296.101.9.6.1.1.1
sleRmonSimpleQueuePortIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port index."
::= { sleRmonSimpleQueueEntry 1 }
-- 1.3.6.1.4.1.6296.101.9.6.1.1.2
sleRmonSimpleQueueSampleVariable OBJECT-TYPE
SYNTAX INTEGER
{
transmitCount(1),
dropCount(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sample variable type."
::= { sleRmonSimpleQueueEntry 2 }
-- 1.3.6.1.4.1.6296.101.9.6.1.1.3
sleRmonSimpleQueueQueueNumber OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The queue number 0~7"
::= { sleRmonSimpleQueueEntry 3 }
-- 1.3.6.1.4.1.6296.101.9.6.1.1.4
sleRmonSimpleQueueSampleInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sample interval. (10: minimum)"
::= { sleRmonSimpleQueueEntry 4 }
-- 1.3.6.1.4.1.6296.101.9.6.1.1.5
sleRmonSimpleQueueRisingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The rising threshold."
::= { sleRmonSimpleQueueEntry 5 }
-- 1.3.6.1.4.1.6296.101.9.6.1.1.6
sleRmonSimpleQueueFallingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The falling threshold."
::= { sleRmonSimpleQueueEntry 6 }
-- 1.3.6.1.4.1.6296.101.9.3.2
-- 1.3.6.1.4.1.6296.101.9.6.2
sleRmonSimpleQueueControl OBJECT IDENTIFIER ::= { sleRmonSimpleQueue 2 }
-- Node definitions
--
-- 1.3.6.1.4.1.6296.101.9.3.2.1
-- 1.3.6.1.4.1.6296.101.9.6.2.1
sleRmonSimpleQueueControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createRmonSimpleQueue(1),
delRmonSimpleQueue(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description"
::= { sleRmonSimpleQueueControl 1 }
-- 1.3.6.1.4.1.6296.101.9.3.2.2
-- 1.3.6.1.4.1.6296.101.9.6.2.2
sleRmonSimpleQueueControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a user command.
"
::= { sleRmonSimpleQueueControl 2 }
-- 1.3.6.1.4.1.6296.101.9.3.2.3
-- 1.3.6.1.4.1.6296.101.9.6.2.3
sleRmonSimpleQueueControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum wait time for the manager for a long running user command.
"
::= { sleRmonSimpleQueueControl 3 }
-- 1.3.6.1.4.1.6296.101.9.3.2.4
-- 1.3.6.1.4.1.6296.101.9.6.2.4
sleRmonSimpleQueueControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time stamp of the last command (end of command)."
::= { sleRmonSimpleQueueControl 4 }
-- 1.3.6.1.4.1.6296.101.9.3.2.5
-- 1.3.6.1.4.1.6296.101.9.6.2.5
sleRmonSimpleQueueControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the last user command."
::= { sleRmonSimpleQueueControl 5 }
-- 1.3.6.1.4.1.6296.101.9.3.2.6
-- 1.3.6.1.4.1.6296.101.9.6.2.6
sleRmonSimpleQueueControlPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port index."
::= { sleRmonSimpleQueueControl 6 }
-- 1.3.6.1.4.1.6296.101.9.3.2.7
-- 1.3.6.1.4.1.6296.101.9.6.2.7
sleRmonSimpleQueueControlSampleVariable OBJECT-TYPE
SYNTAX INTEGER
{
transmitCount(1),
dropCount(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The sample variable type."
::= { sleRmonSimpleQueueControl 7 }
-- 1.3.6.1.4.1.6296.101.9.3.2.6
-- 1.3.6.1.4.1.6296.101.9.6.2.8
sleRmonSimpleQueueControlQueueNumber OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The queue number 0~7"
::= { sleRmonSimpleQueueControl 8 }
-- 1.3.6.1.4.1.6296.101.9.6.2.9
sleRmonSimpleQueueControlSampleInterval OBJECT-TYPE
SYNTAX Integer32 (10..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The sample interval. (10: minimum)"
::= { sleRmonSimpleQueueControl 9 }
-- send an SNMP trap
-- 1.3.6.1.4.1.6296.101.9.3.2.8
-- 1.3.6.1.4.1.6296.101.9.6.2.10
sleRmonSimpleQueueControlRisingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The rising threshold."
::= { sleRmonSimpleQueueControl 10 }
-- 1.3.6.1.4.1.6296.101.9.3.2.9
-- 1.3.6.1.4.1.6296.101.9.6.2.11
sleRmonSimpleQueueControlFallingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The falling threshold."
::= { sleRmonSimpleQueueControl 11 }
-- 1.3.6.1.4.1.6296.101.9.6.3
sleRmonSimpleQueueNotification OBJECT IDENTIFIER ::= { sleRmonSimpleQueue 3 }
-- 1.3.6.1.4.1.6296.101.9.6.3.1
sleRmonSimpleQueueCreated NOTIFICATION-TYPE
OBJECTS { sleRmonSimpleQueueControlRequest, sleRmonSimpleQueueControlTimeStamp, sleRmonSimpleQueueControlReqResult, sleRmonSimpleQueueControlPortIndex, sleRmonSimpleQueueControlSampleVariable,
sleRmonSimpleQueueControlQueueNumber, sleRmonSimpleQueueControlSampleInterval, sleRmonSimpleQueueControlRisingThreshold, sleRmonSimpleQueueControlFallingThreshold }
STATUS current
DESCRIPTION
"createRmonSimpleQueue"
::= { sleRmonSimpleQueueNotification 1 }
-- 1.3.6.1.4.1.6296.101.9.6.3.2
sleRmonSimpleQueueDeleted NOTIFICATION-TYPE
OBJECTS { sleRmonSimpleQueueControlRequest, sleRmonSimpleQueueControlTimeStamp, sleRmonSimpleQueueControlReqResult, sleRmonSimpleQueueControlPortIndex, sleRmonSimpleQueueControlSampleVariable,
sleRmonSimpleQueueControlQueueNumber }
STATUS current
DESCRIPTION
"createRmonSimpleQueue"
::= { sleRmonSimpleQueueNotification 2 }
-- 1.3.6.1.4.1.6296.101.9.5
-- 1.3.6.1.4.1.6296.101.9.7
sleRmonGroup OBJECT-GROUP
OBJECTS { sleHistoryIndex, sleHistoryDataSource, sleHistoryBucketsRequested, sleHistoryBucketsGranted, sleHistoryInterval,
sleHistoryOwner, sleHistoryStatus, sleHistoryControlRequest, sleHistoryControlStatus, sleHistoryControlTimer,
sleHistoryControlTimeStamp, sleHistoryControlReqResult, sleHistoryControlIndex, sleHistoryControlDataSource, sleHistoryControlBucketsRequested,
sleHistoryControlInterval, sleHistoryControlOwner, sleHistoryControlSts, sleAlarmIndex, sleAlarmInterval,
sleAlarmVariable, sleAlarmSampleType, sleAlarmValue, sleAlarmStartupAlarm, sleAlarmRisingThreshold,
sleAlarmFallingThreshold, sleAlarmRisingEventIndex, sleAlarmFallingEventIndex, sleAlarmOwner, sleAlarmStatus,
sleAlarmControlRequest, sleAlarmControlStatus, sleAlarmControlTimer, sleAlarmControlTimeStamp, sleAlarmControlReqResult,
sleAlarmControlIndex, sleAlarmControlInterval, sleAlarmControlVariable, sleAlarmControlSampleType, sleAlarmControlStartupAlarm,
sleAlarmControlRisingThreshold, sleAlarmControlFallingThreshold, sleAlarmControlRisingEventIndex, sleAlarmControlFallingEventIndex, sleAlarmControlOwner,
sleAlarmControlSts, sleEventIndex, sleEventDescription, sleEventType, sleEventCommunity,
sleEventLastTimeSent, sleEventOwner, sleEventStatus, sleEventControlRequest, sleEventControlStatus,
sleEventControlTimer, sleEventControlTimeStamp, sleEventControlReqResult, sleEventControlIndex, sleEventControlDescription,
sleEventControlType, sleEventControlCommunity, sleEventControlOwner, sleEventControlSts, sleEtherStatsIndex,
sleEtherStatsDataSource, sleEtherStatsDropEvents, sleEtherStatsOctets, sleEtherStatsPkts, sleEtherStatsBroadcastPkts,
sleEtherStatsMulticastPkts, sleEtherStatsCRCAlignErrors, sleEtherStatsUndersizePkts, sleEtherStatsOversizePkts, sleEtherStatsFragments,
sleEtherStatsJabbers, sleEtherStatsCollisions, sleEtherStatsPkts64Octets, sleEtherStatsPkts65to127Octets, sleEtherStatsPkts128to255Octets,
sleEtherStatsPkts256to511Octets, sleEtherStatsPkts512to1023Octets, sleEtherStatsPkts1024to1518Octets, sleEtherStatsOwner, sleEtherStatsStatus,
sleEtherStatsClearedTime, sleRmonSimplePortIndex, sleRmonSimpleSampleVariable, sleRmonSimpleSampleInterval, sleRmonSimpleRisingThreshold,
sleRmonSimpleFallingThreshold, sleRmonSimpleControlRequest, sleRmonSimpleControlStatus, sleRmonSimpleControlTimer, sleRmonSimpleControlTimeStamp,
sleRmonSimpleControlReqResult, sleRmonSimpleControlPortIndex, sleRmonSimpleControlSampleVariable, sleRmonSimpleControlRisingThreshold, sleRmonSimpleControlFallingThreshold,
sleRmonSimpleControlSampleInterval, sleRmonSimpleQueuePortIndex, sleRmonSimpleQueueQueueNumber, sleRmonSimpleQueueSampleVariable, sleRmonSimpleQueueSampleInterval,
sleRmonSimpleQueueRisingThreshold, sleRmonSimpleQueueFallingThreshold, sleRmonSimpleQueueControlRequest, sleRmonSimpleQueueControlStatus, sleRmonSimpleQueueControlTimer,
sleRmonSimpleQueueControlTimeStamp, sleRmonSimpleQueueControlReqResult, sleRmonSimpleQueueControlPortIndex, sleEtherStatsControlRequest, sleEtherStatsControlStatus,
sleEtherStatsControlTimer, sleEtherStatsControlTimeStamp, sleEtherStatsControlReqResult, sleEtherStatsControlIfIndex, sleRmonSimpleQueueControlQueueNumber,
sleRmonSimpleQueueControlSampleVariable, sleRmonSimpleQueueControlSampleInterval, sleRmonSimpleQueueControlRisingThreshold, sleRmonSimpleQueueControlFallingThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleRmon 7 }
-- 1.3.6.1.4.1.6296.101.9.6
-- 1.3.6.1.4.1.6296.101.9.8
sleRmonNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { sleHistoryCreated, sleHistoryDestroyed, sleHistoryProfileChanged, sleAlarmCreated, sleAlarmDestroyed,
sleAlarmProfileChanged, sleEventCreated, sleEventDestroyed, sleEventProfileChanged, sleRmonSimpleQueueCreated,
sleRmonSimpleQueueDeleted, sleRmonSimpleDeleted, sleRmonSimpleCreated }
STATUS current
DESCRIPTION
"Description."
::= { sleRmon 8 }
END
--