mibs/MIBS/dell/Dell-Vendor-MIB
2023-12-05 12:25:34 +01:00

487 lines
17 KiB
Plaintext

Dell-Vendor-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, TimeTicks
FROM RFC1155-SMI
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32, IpAddress,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, RowStatus, TEXTUAL-CONVENTION
FROM SNMPv2-TC;
-- Dell MIB tree
dell OBJECT IDENTIFIER ::= { enterprises 674 }
-- Dell PowerConnect MIB tree
dellLan OBJECT IDENTIFIER ::= { dell 10895 }
-- Dell standard MIB tree for all future PowerConnect product. There
-- are already some earlier objects registered under 10895 so that it
-- is necessary to carve out this subtree under dellLan.5000 in order
-- to prevent conflict with existing MIB objects.
dellLanStandard OBJECT IDENTIFIER ::= { dellLan 5000 }
-- Dell common and device independent MIB objects.
dellLanCommon OBJECT IDENTIFIER ::= { dellLanStandard 1 }
-- Dell extension MIB objects for specific technology or device.
dellLanExtension OBJECT IDENTIFIER ::= { dellLanStandard 2 }
powerConnectVendorMIB MODULE-IDENTITY
LAST-UPDATED "200501150000Z"
ORGANIZATION "Dell Inc."
CONTACT-INFO
"support.dell.com"
DESCRIPTION
"The private MIB module definition for the Dell PowerConnect
Devices. This MIB allows PowerConnect devices to be
integrated into Dell ITA management system."
::= { dellLan 3000 }
EnvMonState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents the state of a device being monitored.
Valid values are:
normal(1): the environment is good, such as low
temperature.
warning(2): the environment is bad, such as temperature
above normal operation range but not too
high.
critical(3): the environment is very bad, such as
temperature much higher than normal
operation limit.
shutdown(4): the environment is the worst, the system
should be shutdown immediately.
notPresent(5): the environmental monitor is not present,
such as temperature sensors do not exist.
notFunctioning(6): the environmental monitor does not
function properly, such as a temperature
sensor generates a abnormal data like
1000 C.
"
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3),
shutdown(4),
notPresent(5),
notFunctioning(6)
}
dellVendorMIBObjects OBJECT IDENTIFIER ::= { powerConnectVendorMIB 1 }
dellVendorNotifications OBJECT IDENTIFIER ::= { powerConnectVendorMIB 2 }
hardware OBJECT IDENTIFIER ::= { dellVendorMIBObjects 2 }
productIdentification OBJECT IDENTIFIER ::= { hardware 100 }
productStatus OBJECT IDENTIFIER ::= { hardware 110 }
--
--
-- productIdentification
--
productIdentificationDisplayName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Name of this product for display purposes."
::= { productIdentification 1}
productIdentificationDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A short description of this product such as: Ethernet Router Switch."
::= { productIdentification 2}
productIdentificationVendor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the product manufacturer, such as: Dell Inc."
::= { productIdentification 3 }
productIdentificationVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The version of this product."
::= { productIdentification 4 }
productIdentificationBuildNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The software build number of the product."
::= { productIdentification 5 }
productIdentificationURL OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The URL of the web-based application to manage this device, should the device provide one.
The format of the value held by this object is: http://<device IP address>."
::= { productIdentification 6 }
productIdentificationDeviceNetworkName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device Name."
::= { productIdentification 7 }
productIdentificationPerUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF ProductIdentificationPerBoxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identification specific to product instance and, in case of stackable products, per unit. If the product is not stackable,
it will be considered a stack of one unit and therefore this table will contain one conceptual row only."
::= { productIdentification 8 }
productIdentificationPerUnitEntry OBJECT-TYPE
SYNTAX ProductIdentificationPerBoxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This row applies to a unit in a stackable product. "
INDEX { productIdentificationPerBoxIndex }
::= { productIdentificationPerUnitTable 1 }
ProductIdentificationPerBoxEntry ::= SEQUENCE {
productIdentificationPerBoxIndex INTEGER,
productIdentificationSerialNumber DisplayString,
productIdentificationAssetTag DisplayString,
productIdentificationServiceTag DisplayString,
productIdentificationBootromVersion DisplayString
}
productIdentificationPerBoxIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the stack unit to which this conceptual row corresponds.
Note that the index will be the same index as the index
of a 'chassis' physical entity in the entity MIB of the product."
::= { productIdentificationPerUnitEntry 1 }
productIdentificationSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial number of the product."
::= { productIdentificationPerUnitEntry 2 }
productIdentificationAssetTag OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Asset tag of the product."
::= { productIdentificationPerUnitEntry 3 }
productIdentificationServiceTag OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Service tag of the product."
::= { productIdentificationPerUnitEntry 4 }
productIdentificationBootromVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The boot image version of the product."
::= { productIdentificationPerUnitEntry 6 }
productIdentificationBannerMotd OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..1500))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Use to assign CLI attention banner. The banner should support 1500 characters."
::= { productIdentification 9 }
productIdentificationBannerMotdAckMode OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "If enable is selected, user will be required to acknowledge the banner displayed on the console. The user would have to type y or n to continue to the login prompt. If n is typed, the session is terminated and no further communication is allowed on that session. However, serial connection will not get terminated if user does not enter y. Use disable option to disable banner acknowledge."
::= { productIdentification 10 }
--
-- productStatus
--
productStatusGlobalStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(3),
non-critical(4),
critical(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the product.This is a rollup for the entire product.
The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal.
This variable can take the following values:
3: OK
If fans and power supplies are functioning and the system did not reboot because of a HW watchdog failure
or a SW fatal error condition.
4: Non-critical
If at least one power supply is not functional or the system rebooted at least once because of a HW watchdog failure
or a SW fatal error condition.
5: Critical
If at least one fan is not functional, possibly causing a dangerous warming up of the device."
::= { productStatus 1 }
productStatusLastGlobalStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(3),
non-critical(4),
critical(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The status before the current status which induced an initiative to issue a global status change trap."
::= { productStatus 2 }
productStatusTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The last time that the product global status has been updated.
The time will be given in TimeTicks"
::= { productStatus 3 }
productStatusGetTimeOut OBJECT-TYPE
SYNTAX INTEGER(1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Suggested time out value in milliseconds for how long the SNMP getter
should wait while attempting to poll the product SNMP service."
::= { productStatus 4 }
productStatusRefreshRate OBJECT-TYPE
SYNTAX INTEGER(1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Rate in seconds at which the SNMP service cached data is being updated."
::= { productStatus 5 }
productStatusGeneratingTrapsFlag OBJECT-TYPE
SYNTAX INTEGER { true(1),
false(2),
disabled(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates if this SNMP service is generating SNMP Traps.
This variable can take the following values:
1: true - The device is capable and currently configured to generate traps if necessary.
2: false - The device is not capable of generating traps.
3: disabled - The device is capable but not configured to generate traps.
"
::= { productStatus 6 }
productStatusEnvironment OBJECT IDENTIFIER ::= { productStatus 7}
envMonFanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnvMonFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of fan status maintained by the environmental
monitor. Not Supported by Dell Modular Blade Server switches."
::= { productStatusEnvironment 1 }
envMonFanStatusEntry OBJECT-TYPE
SYNTAX EnvMonFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the fan status table, representing the status of
the associated fan maintained by the environmental monitor.
Not Supported by Dell Modular Blade Server switches."
INDEX { envMonFanStatusIndex }
::= { envMonFanStatusTable 1 }
EnvMonFanStatusEntry ::=
SEQUENCE {
envMonFanStatusIndex INTEGER,
envMonFanStatusDescr DisplayString,
envMonFanState EnvMonState
}
envMonFanStatusIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index for the fan being instrumented. This index is
for SNMP purposes only, and has no intrinsic meaning. Not
Supported by Dell Modular Blade Server switches."
::= { envMonFanStatusEntry 1 }
envMonFanStatusDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of the fan being instrumented.
This description is a short textual label, suitable
as a human-sensible identification for the rest of
the information in the entry. Not Supported by Dell
Modular Blade Server switches."
::= { envMonFanStatusEntry 2 }
envMonFanState OBJECT-TYPE
SYNTAX EnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the fan being instrumented.
Not Supported by Dell Modular Blade Server switches."
::= { envMonFanStatusEntry 3 }
envMonSupplyStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnvMonSupplyStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of power supply status maintained by the
environmental monitor card."
::= { productStatusEnvironment 2 }
envMonSupplyStatusEntry OBJECT-TYPE
SYNTAX EnvMonSupplyStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the power supply status table, representing the
status of the associated power supply maintained by the
environmental monitor card."
INDEX { envMonSupplyStatusIndex }
::= { envMonSupplyStatusTable 1 }
EnvMonSupplyStatusEntry ::=
SEQUENCE {
envMonSupplyStatusIndex INTEGER ,
envMonSupplyStatusDescr DisplayString,
envMonSupplyState EnvMonState,
envMonSupplySource INTEGER
}
envMonSupplyStatusIndex OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index for the power supply being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning."
::= { envMonSupplyStatusEntry 1 }
envMonSupplyStatusDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of the power supply being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry."
::= { envMonSupplyStatusEntry 2 }
envMonSupplyState OBJECT-TYPE
SYNTAX EnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the power supply being instrumented."
::= { envMonSupplyStatusEntry 3 }
envMonSupplySource OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ac(2),
dc(3),
externalPowerSupply(4),
internalRedundant(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power supply source.
unknown - Power supply source unknown
ac - AC power supply
dc - DC power supply
externalPowerSupply - External power supply
internalRedundant - Internal redundant power supply
"
::= { envMonSupplyStatusEntry 4 }
--
-- trap definitions
--
dellVendorTraps OBJECT IDENTIFIER ::= { dellVendorNotifications 1 }
dellVendorTrapsPrefix OBJECT IDENTIFIER ::= { dellVendorTraps 0 }
productStatusGlobalStatusChange NOTIFICATION-TYPE
OBJECTS { productStatusGlobalStatus,
productStatusLastGlobalStatus,
productStatusTimeStamp }
STATUS current
DESCRIPTION "This trap is sent when the product global status changes."
--#TYPE "Product Global Status Change."
--#SUMMARY "The product global status has changed from %d to %d at time %d."
--#ARGUMENTS {1,0,2}
::= {dellVendorTrapsPrefix 1 }
END