LAMBDATRAIL-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises, private, NetworkAddress,
|
|
IpAddress, Counter, Gauge, TimeTicks
|
|
FROM RFC1155-SMI
|
|
OBJECT-TYPE
|
|
FROM RFC-1212;
|
|
|
|
DisplayString ::=
|
|
OCTET STRING
|
|
-- This data type is used to model textual information taken
|
|
-- from the NVT ASCII character set. By convention, objects
|
|
-- with this syntax are declared as having
|
|
|
|
|
|
|
|
--
|
|
-- SIZE (0..255)
|
|
|
|
PhysAddress ::=
|
|
OCTET STRING
|
|
-- This data type is used to model media addresses. For many
|
|
-- types of media, this will be in a binary representation.
|
|
-- For example, an ethernet address would be represented as
|
|
-- a string of 6 octets.
|
|
|
|
-- revision date: Apr. 09, 2010
|
|
|
|
deltanet OBJECT IDENTIFIER ::= { enterprises 35616 }
|
|
|
|
-- Deltanet AG Specific Objects
|
|
|
|
snmpAgent OBJECT IDENTIFIER ::= { deltanet 1 }
|
|
productType OBJECT IDENTIFIER ::= { deltanet 2 }
|
|
|
|
cwdm OBJECT IDENTIFIER ::= { productType 1 }
|
|
|
|
lambdatrail OBJECT IDENTIFIER ::= { cwdm 1 }
|
|
|
|
-- Software group
|
|
|
|
agentSw OBJECT IDENTIFIER ::= { snmpAgent 1 }
|
|
|
|
agentSoftwareMajorVer OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The major software version number of the agent
|
|
run time image."
|
|
::= { agentSw 1 }
|
|
|
|
agentSoftwareMinorVer OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minor software version number of the agent
|
|
run time image."
|
|
::= { agentSw 2 }
|
|
|
|
agentOutBandBaudRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
b9600(9600),
|
|
b19200(19200),
|
|
b38400(38400),
|
|
b57600(57600),
|
|
b115200(115200)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The baud rate setting for the out-of-band port."
|
|
::= { snmpAgent 2 }
|
|
|
|
agentConsoleIdleTimeouts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"timeouts is 0 or 60-86400, unit is second, 0: never idle,
|
|
default is 600"
|
|
::= { snmpAgent 3 }
|
|
|
|
agentPrompt OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { snmpAgent 4 }
|
|
|
|
agentBootMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual(1),
|
|
dhcp(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { snmpAgent 5 }
|
|
|
|
agentIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The agent's administrative IP address. The
|
|
current operational IP address can be obtained from
|
|
the ipAdEntAddr in the ipAddrTable. This parameter
|
|
will take effect only after a agent restart or
|
|
agent reset. This parameter will always be updated
|
|
in the EEPROM."
|
|
::= { snmpAgent 6 }
|
|
|
|
agentIpNetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The agent's administrative IP subnet mask. The
|
|
current operational IP subnet mask can be obtained from
|
|
the ipAdEntMask in the ipAddrTable. This parameter
|
|
will take effect only after a agent restart or
|
|
agent reset. This parameter will always be updated
|
|
in the EEPROM."
|
|
::= { snmpAgent 7 }
|
|
|
|
agentDefaultGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The agent's administrative default gateway IP address.
|
|
The current operational IP default gateway IP address
|
|
can be obtained from the ipRouteDest in the ipRouteTable.
|
|
This parameter will take effect only after a agent restart or
|
|
agent reset. This parameter will always be updated
|
|
in the EEPROM."
|
|
::= { snmpAgent 8 }
|
|
|
|
agentPrimaryDnsServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { snmpAgent 9 }
|
|
|
|
agentSecondaryDnsServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { snmpAgent 10 }
|
|
|
|
agentSnmpServer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { snmpAgent 11 }
|
|
|
|
agentHttpServer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { snmpAgent 12 }
|
|
|
|
agentTelnet OBJECT IDENTIFIER ::= { snmpAgent 13 }
|
|
|
|
agentTelnetServer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTelnet 1 }
|
|
|
|
agentTelnetIdleTimeouts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"timeouts is 0 or 60-86400, unit is second, 0: never idle,
|
|
default is 600"
|
|
::= { agentTelnet 2 }
|
|
|
|
agentTelnetMaxSessions OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTelnet 3 }
|
|
|
|
agentFtpServer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { snmpAgent 14 }
|
|
|
|
agentTftpServer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { snmpAgent 15 }
|
|
|
|
-- the agent trap target group
|
|
|
|
agentSendTrap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { snmpAgent 16 }
|
|
|
|
agentTrapTargetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgentTrapTargetEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { snmpAgent 17 }
|
|
|
|
agentTrapTargetEntry OBJECT-TYPE
|
|
SYNTAX AgentTrapTargetEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
INDEX { agentTrapIndex }
|
|
::= { agentTrapTargetTable 1 }
|
|
|
|
AgentTrapTargetEntry ::= SEQUENCE {
|
|
agentTrapIndex INTEGER,
|
|
agentTrapTargetIpAddr IpAddress,
|
|
agentTrapTargetComm DisplayString
|
|
}
|
|
|
|
agentTrapIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTrapTargetEntry 1 }
|
|
|
|
agentTrapTargetIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTrapTargetEntry 2 }
|
|
|
|
agentTrapTargetComm OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTrapTargetEntry 3 }
|
|
|
|
-- the agent email alert group
|
|
|
|
agentEmailAlert OBJECT IDENTIFIER ::= { snmpAgent 18 }
|
|
|
|
agentSendEmailAlert OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentEmailAlert 1 }
|
|
|
|
agentEmailServerIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentEmailAlert 2 }
|
|
|
|
agentRecipientTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgentRecipientEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentEmailAlert 3 }
|
|
|
|
agentRecipientEntry OBJECT-TYPE
|
|
SYNTAX AgentRecipientEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
INDEX { agentRecipientIndex }
|
|
::= { agentRecipientTable 1 }
|
|
|
|
AgentRecipientEntry ::= SEQUENCE {
|
|
agentRecipientIndex INTEGER,
|
|
agentRecipientEmailAddress DisplayString
|
|
}
|
|
|
|
agentRecipientIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentRecipientEntry 1 }
|
|
|
|
agentRecipientEmailAddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..47))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentRecipientEntry 2 }
|
|
|
|
-- the agent syslog group
|
|
|
|
agentSyslog OBJECT IDENTIFIER ::= { snmpAgent 19 }
|
|
|
|
agentSyslogOnOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentSyslog 1 }
|
|
|
|
agentSaveLogsToFlash OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentSyslog 2 }
|
|
|
|
agentClearAllLogs OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
access(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentSyslog 3 }
|
|
|
|
agentSyslogServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgentSyslogServerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentSyslog 4 }
|
|
|
|
agentSyslogServerEntry OBJECT-TYPE
|
|
SYNTAX AgentSyslogServerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
INDEX { agentSyslogServerIndex }
|
|
::= { agentSyslogServerTable 1 }
|
|
|
|
AgentSyslogServerEntry ::= SEQUENCE {
|
|
agentSyslogServerIndex INTEGER,
|
|
agentSyslogServerIpAddr IpAddress
|
|
}
|
|
|
|
agentSyslogServerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentSyslogServerEntry 1 }
|
|
|
|
agentSyslogServerIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentSyslogServerEntry 2 }
|
|
|
|
-- the agent secure ip group
|
|
|
|
agentSecureIp OBJECT IDENTIFIER ::= { snmpAgent 20 }
|
|
|
|
agentSecureIpOnOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentSecureIp 1 }
|
|
|
|
agentSecureIpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgentSecureIpEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentSecureIp 2 }
|
|
|
|
agentSecureIpEntry OBJECT-TYPE
|
|
SYNTAX AgentSecureIpEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
INDEX { agentSecureIpIndex }
|
|
::= { agentSecureIpTable 1 }
|
|
|
|
AgentSecureIpEntry ::= SEQUENCE {
|
|
agentSecureIpIndex INTEGER,
|
|
agentSecureIpAddr IpAddress
|
|
}
|
|
|
|
agentSecureIpIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentSecureIpEntry 1 }
|
|
|
|
agentSecureIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentSecureIpEntry 2 }
|
|
|
|
-- the agent ntp group
|
|
|
|
agentTime OBJECT IDENTIFIER ::= { snmpAgent 21 }
|
|
|
|
agentNtpClientOnOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 1 }
|
|
|
|
agentNtpServerIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 2 }
|
|
|
|
agentNtpUpdateInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (60..86400)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"unit is second"
|
|
::= { agentTime 3 }
|
|
|
|
agentTimeZoneName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 4 }
|
|
|
|
agentTimeZoneHoursOffsetWithGMT OBJECT-TYPE
|
|
SYNTAX INTEGER (-23..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 5 }
|
|
|
|
agentTimeZoneMinutesOffsetWithGMT OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 6 }
|
|
|
|
agentSummerTime OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
summer(1),
|
|
Sun(2),
|
|
lastSun(3),
|
|
manual(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 7 }
|
|
|
|
agentSummerTimeBeginMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
jan(1),
|
|
feb(2),
|
|
mar(3),
|
|
apr(4),
|
|
may(5),
|
|
jun(6),
|
|
jul(7),
|
|
aug(8),
|
|
sep(9),
|
|
oct(10),
|
|
nov(11),
|
|
dec(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 8 }
|
|
|
|
agentSummerTimeBeginNth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
first(1),
|
|
second(2),
|
|
third(3),
|
|
fourth(4),
|
|
last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 9 }
|
|
|
|
agentSummerTimeBeginWeekday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sun(1),
|
|
mon(2),
|
|
tue(3),
|
|
wed(4),
|
|
thu(5),
|
|
fri(6),
|
|
sat(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 10 }
|
|
|
|
agentSummerTimeBeginHour OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 11 }
|
|
|
|
agentSummerTimeBeginMinute OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 12 }
|
|
|
|
agentSummerTimeEndMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
jan(1),
|
|
feb(2),
|
|
mar(3),
|
|
apr(4),
|
|
may(5),
|
|
jun(6),
|
|
jul(7),
|
|
aug(8),
|
|
sep(9),
|
|
oct(10),
|
|
nov(11),
|
|
dec(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 13 }
|
|
|
|
agentSummerTimeEndNth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
first(1),
|
|
second(2),
|
|
third(3),
|
|
fourth(4),
|
|
last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 14 }
|
|
|
|
agentSummerTimeEndWeekday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sun(1),
|
|
mon(2),
|
|
tue(3),
|
|
wed(4),
|
|
thu(5),
|
|
fri(6),
|
|
sat(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 15 }
|
|
|
|
agentSummerTimeEndHour OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 16 }
|
|
|
|
agentSummerTimeEndMinute OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" "
|
|
::= { agentTime 17 }
|
|
|
|
agentSaveRunningCfg OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
saveConfiguration(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this variable will save current configuration.
|
|
the value will be reset to 1 after succeed."
|
|
::= { snmpAgent 22 }
|
|
|
|
agentDefault OBJECT IDENTIFIER ::= { snmpAgent 23 }
|
|
|
|
agentKeepCurrentIP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
keepCurrentIP(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this variable will keep current IP configuration
|
|
(IP address, Subnet Mask, Default Gateway and Domain Name Servers).
|
|
the value will be reset to 1 after succeed."
|
|
::= { agentDefault 1 }
|
|
|
|
agentKeepCurrentSNMP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
keepCurrentSNMP(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this variable will keep current SNMP settings
|
|
(System information, SNMP communities and SNMP Trap information).
|
|
the value will be reset to 1 after succeed."
|
|
::= { agentDefault 2 }
|
|
|
|
agentKeepCurrentPort OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
keepCurrentPort(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this variable will keep current port settings.
|
|
the value will be reset to 1 after succeed."
|
|
::= { agentDefault 3 }
|
|
|
|
agentKeepCurrentUser OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
keepCurrentUser(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this variable will keep current User settings.
|
|
the value will be reset to 1 after succeed."
|
|
::= { agentDefault 4 }
|
|
|
|
agentFactoryDefault OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
factoryDefault(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this variable will use factory default configuration and reload.
|
|
the value will be reset to 1 after succeed."
|
|
::= { agentDefault 5 }
|
|
|
|
agentReloadSystem OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
reloadSystem(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this variable will reload system.
|
|
the value will be reset to 1 after succeed."
|
|
::= { snmpAgent 24 }
|
|
|
|
agentTftpUpgrade OBJECT IDENTIFIER ::= { snmpAgent 25 }
|
|
|
|
agentTftpServerIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specify the IP address of the TFTP server where the binary
|
|
code is stored."
|
|
::= { agentTftpUpgrade 1 }
|
|
|
|
agentUpgradeFileName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specify the file name of the binary code to be upgraded."
|
|
::= { agentTftpUpgrade 2 }
|
|
|
|
agentUpgradeState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
start(2),
|
|
inProgress(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the variable 1 will start the upgrade process."
|
|
::= { agentTftpUpgrade 3 }
|
|
|
|
-- system
|
|
|
|
systemTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { lambdatrail 1 }
|
|
|
|
systemPower1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notplugged(1),
|
|
off(2),
|
|
on(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { lambdatrail 2 }
|
|
|
|
systemPower2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notplugged(1),
|
|
off(2),
|
|
on(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { lambdatrail 3 }
|
|
|
|
systemFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
failure(1),
|
|
off(2),
|
|
on(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { lambdatrail 4 }
|
|
|
|
systemFan1Selection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysOff(1),
|
|
alwaysOn(2),
|
|
byTemperature(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { lambdatrail 5 }
|
|
|
|
systemFan1OnTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { lambdatrail 6 }
|
|
|
|
systemFan1OffTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { lambdatrail 7 }
|
|
|
|
systemFan2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
failure(1),
|
|
off(2),
|
|
on(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { lambdatrail 8 }
|
|
|
|
systemFan2Selection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysOff(1),
|
|
alwaysOn(2),
|
|
byTemperature(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { lambdatrail 9 }
|
|
|
|
systemFan2OnTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { lambdatrail 10 }
|
|
|
|
systemFan2OffTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { lambdatrail 11 }
|
|
|
|
-- port table
|
|
|
|
portTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of interface entries."
|
|
::= { lambdatrail 12 }
|
|
|
|
portEntry OBJECT-TYPE
|
|
SYNTAX PortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A port entry containing objects
|
|
below for a port."
|
|
INDEX { portId }
|
|
::= { portTable 1 }
|
|
|
|
PortEntry ::= SEQUENCE {
|
|
portId INTEGER,
|
|
portLicensed INTEGER,
|
|
portEnabled INTEGER,
|
|
portAPSD INTEGER,
|
|
portLinePlugged INTEGER,
|
|
portLineLink INTEGER,
|
|
portLineWavelength INTEGER,
|
|
portLineTxPower INTEGER,
|
|
portLineRxPower INTEGER,
|
|
portLineLaserTemp INTEGER,
|
|
portLineLaserBias INTEGER,
|
|
portClientPlugged INTEGER,
|
|
portClientLink INTEGER,
|
|
portClientWavelength INTEGER,
|
|
portClientTxPower INTEGER,
|
|
portClientRxPower INTEGER,
|
|
portClientLaserTemp INTEGER,
|
|
portClientLaserBias INTEGER,
|
|
portName DisplayString
|
|
}
|
|
|
|
portId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each interface."
|
|
::= { portEntry 1 }
|
|
|
|
portLicensed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(1),
|
|
yes(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portEntry 2 }
|
|
|
|
portEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portEntry 3 }
|
|
|
|
portAPSD OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portEntry 4 }
|
|
|
|
portLinePlugged OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPlugged(1),
|
|
plugged(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portEntry 5 }
|
|
|
|
portLineLink OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(1),
|
|
up(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portEntry 6 }
|
|
|
|
portLineWavelength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"unit is nanometer, -1 means not available"
|
|
::= { portEntry 7 }
|
|
|
|
portLineTxPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available"
|
|
::= { portEntry 8 }
|
|
|
|
portLineRxPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available"
|
|
::= { portEntry 9 }
|
|
|
|
portLineLaserTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"unit is Celsius degree, -1 means not available"
|
|
::= { portEntry 10 }
|
|
|
|
portLineLaserBias OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"unit is mini ampere, -1 means not available"
|
|
::= { portEntry 11 }
|
|
|
|
portClientPlugged OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPlugged(1),
|
|
plugged(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portEntry 12 }
|
|
|
|
portClientLink OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(1),
|
|
up(2),
|
|
notAvailable (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portEntry 13 }
|
|
|
|
portClientWavelength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"unit is nanometer, -1 means not available"
|
|
::= { portEntry 14 }
|
|
|
|
portClientTxPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available"
|
|
::= { portEntry 15 }
|
|
|
|
portClientRxPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"unit is 1/1000 dBm, for example, 1234 means 1.234 dBm, -1234 means -1.234dBm, -1 means not available"
|
|
::= { portEntry 16 }
|
|
|
|
portClientLaserTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"unit is Celsius degree, -1 means not available"
|
|
::= { portEntry 17 }
|
|
|
|
portClientLaserBias OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"unit is mini ampere, -1 means not available"
|
|
::= { portEntry 18 }
|
|
|
|
portName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { portEntry 19 }
|
|
|
|
--
|
|
|
|
usablePorts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { lambdatrail 13 }
|
|
|
|
END
|