-- DLINKSW-POE-MIB.mib : D-Link extensions to POWER-ETHERNET-MIB (PoE)
|
|
--
|
|
-- Copyright (c) 2017 D-Link Corporation, all rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
DLINKSW-POE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
DisplayString,TruthValue
|
|
FROM SNMPv2-TC
|
|
InetAddressType, InetAddress
|
|
FROM INET-ADDRESS-MIB
|
|
PortList
|
|
FROM Q-BRIDGE-MIB
|
|
pethMainPseGroupIndex, pethPsePortIndex, pethPsePortShortCounter,
|
|
pethPsePortOverLoadCounter, pethPsePortPowerDeniedCounter
|
|
FROM POWER-ETHERNET-MIB
|
|
dlinkIndustrialCommon
|
|
FROM DLINK-ID-REC-MIB;
|
|
|
|
|
|
dlinkSwPoeExtMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201703150000Z"
|
|
ORGANIZATION "D-Link Corp."
|
|
CONTACT-INFO
|
|
" D-Link Corporation
|
|
Postal: No. 289, Sinhu 3rd Rd., Neihu District,
|
|
Taipei City 114, Taiwan, R.O.C
|
|
Tel: +886-2-66000123
|
|
E-mail: tsd@dlink.com.tw
|
|
"
|
|
DESCRIPTION
|
|
"A MIB module for extending POWER-ETHERNET-MIB specified in
|
|
RFC 3621.
|
|
"
|
|
REVISION "201305290000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
REVISION "201309240000Z"
|
|
DESCRIPTION
|
|
"Add dPoeGroupIfLedMode node."
|
|
REVISION "201703150000Z"
|
|
DESCRIPTION
|
|
"Add dPoeIfPdAliveCfgTable table to support PD alive check feature."
|
|
::= { dlinkIndustrialCommon 24 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
dPoeMIBNotifications OBJECT IDENTIFIER ::= { dlinkSwPoeExtMIB 0 }
|
|
dPoeMIBObjects OBJECT IDENTIFIER ::= { dlinkSwPoeExtMIB 1 }
|
|
dPoeMIBConformance OBJECT IDENTIFIER ::= { dlinkSwPoeExtMIB 2 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
dPoeGroupCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DPoeGroupCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table consists of a list of group configurations for PoE.
|
|
Group means box in the stack or module in a rack.
|
|
For non-modular devices, the pethMainPseGroupIndex is 1.
|
|
"
|
|
::= { dPoeMIBObjects 1 }
|
|
|
|
dPoeGroupCfgEntry OBJECT-TYPE
|
|
SYNTAX DPoeGroupCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry contains the system configuration of the PoE on a group."
|
|
INDEX { pethMainPseGroupIndex }
|
|
::= { dPoeGroupCfgTable 1 }
|
|
|
|
DPoeGroupCfgEntry ::= SEQUENCE {
|
|
dPoeGroupPolicyPreempt TruthValue,
|
|
dPoeGroupClearIfStatistic PortList,
|
|
dPoeGroupIfLedMode INTEGER
|
|
}
|
|
|
|
dPoeGroupPolicyPreempt OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object configures whether to disconnect the PD which is powered
|
|
with lower priority in order to release the power to the new connected
|
|
PD with higher priority under power shortage condition.
|
|
If this object is 'false', then the policy is first in first serviced.
|
|
Thus the new PD will not be serviced if the power budget is running out.
|
|
If this object is 'true', then the power provisioned to PD
|
|
with lower priority can be preempted to release the power to the new
|
|
connected PD with higher priority. "
|
|
DEFVAL { false }
|
|
::= { dPoeGroupCfgEntry 1 }
|
|
|
|
dPoeGroupClearIfStatistic OBJECT-TYPE
|
|
SYNTAX PortList
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to clear the PoE statistics of pethPsePortEntry
|
|
for specified ports.
|
|
"
|
|
::= { dPoeGroupCfgEntry 2 }
|
|
|
|
dPoeGroupIfLedMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
poeMode(1),
|
|
linkMode(2),
|
|
invalid(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For some devices,port LED can indicate either poe status or link status.
|
|
This object is used to configure or display port LED mode.
|
|
poeMode(1) - indicates poe status.
|
|
linkMode(2) - indicates link status.
|
|
|
|
For other devices have LEDs to indicate poe status and link status separately,
|
|
this object only can get value of invalid(3) to mean this node is meaningless.
|
|
"
|
|
::= { dPoeGroupCfgEntry 3 }
|
|
-------------------------------------------------------------------------------
|
|
dPoeGroupInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DPoEGroupInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table consists of a list of PoE information for groups."
|
|
::= { dPoeMIBObjects 2 }
|
|
|
|
dPoeGroupInfoEntry OBJECT-TYPE
|
|
SYNTAX DPoEGroupInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry contains the system information of the PoE on a group."
|
|
INDEX { pethMainPseGroupIndex }
|
|
::= { dPoeGroupInfoTable 1 }
|
|
|
|
DPoEGroupInfoEntry ::= SEQUENCE {
|
|
dPoeGroupMaxPorts Integer32,
|
|
dPoeGroupHWVersion DisplayString,
|
|
dPoeGroupSWVersion DisplayString
|
|
}
|
|
|
|
dPoeGroupMaxPorts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the maximum number of ports that the group can support."
|
|
::= { dPoeGroupInfoEntry 1 }
|
|
|
|
dPoeGroupHWVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates H/W version of PoE chip."
|
|
::= { dPoeGroupInfoEntry 2 }
|
|
|
|
dPoeGroupSWVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates firmware version of PoE chip."
|
|
::= { dPoeGroupInfoEntry 3 }
|
|
|
|
------------------------------------------------------------------------------------------------------
|
|
dPoeIfObjects OBJECT IDENTIFIER ::= { dPoeMIBObjects 3 }
|
|
|
|
dPoeIfCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DPoeIfCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table consists of a list of PoE configuration
|
|
information for ports."
|
|
::= { dPoeIfObjects 1 }
|
|
|
|
dPoeIfCfgEntry OBJECT-TYPE
|
|
SYNTAX DPoeIfCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry contains PoE configuration on a port."
|
|
INDEX {
|
|
pethMainPseGroupIndex,
|
|
pethPsePortIndex
|
|
}
|
|
::= { dPoeIfCfgTable 1 }
|
|
|
|
DPoeIfCfgEntry ::= SEQUENCE {
|
|
dPoeIfState INTEGER,
|
|
dPoeIfMaxPower Integer32,
|
|
dPoeIfTimeRange DisplayString,
|
|
dPoeIfLegacyPdEnabled TruthValue
|
|
}
|
|
|
|
dPoeIfState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto(1),
|
|
never(2),
|
|
static(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the PoE state of the entry.
|
|
auto(1) - the port will automatically detect the PD and provision
|
|
power to the PD. The max wattage value which can be provisioned
|
|
to the port is determined by dPoeIfMaxPower. If dPoeIfMaxPower
|
|
is unspecified, then the class of the PD auto determines the
|
|
maximum wattage which can be provisioned. The PD will not be
|
|
provisioned if it requests more wattage than the max wattage
|
|
which is determined.
|
|
never(2) - indicates the port will not supply power to connected PD;
|
|
static(3) - indicates manager pre-allocate power budget to the port
|
|
by configuring the dPoeIfMaxPower object. The power budget is allocated
|
|
to the port even though there is no PD connected to the port.
|
|
If dPoeIfMaxPower is not configured, default value is 15400mW for 802.3af
|
|
and 30000mW for 802.3at."
|
|
DEFVAL {auto}
|
|
::= { dPoeIfCfgEntry 1 }
|
|
|
|
dPoeIfMaxPower OBJECT-TYPE
|
|
SYNTAX Integer32( 0 | 1000..30000)
|
|
UNITS "milliwatts"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the max wattage value which can
|
|
be provisioned to the port.
|
|
Note: This object is valid only while the dPoeIfState
|
|
object is configured as auto or static."
|
|
::= { dPoeIfCfgEntry 2 }
|
|
|
|
dPoeIfTimeRange OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the name of time-range profile to delineate
|
|
the activation period.
|
|
A zero length string indicates the time-range is not specified.
|
|
Note: This object is valid only while the dPoeIfState is 'auto'."
|
|
::= { dPoeIfCfgEntry 3 }
|
|
|
|
dPoeIfLegacyPdEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the state of legacy PD support."
|
|
DEFVAL { false }
|
|
::= { dPoeIfCfgEntry 4 }
|
|
|
|
------------------------------------------------------------------------------------------------------
|
|
dPoeIfInfoObjects OBJECT IDENTIFIER ::= { dPoeIfObjects 2 }
|
|
|
|
dPoeIfStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DPoeIfStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table consists of a list of PoE status for ports."
|
|
::= { dPoeIfInfoObjects 1 }
|
|
|
|
dPoeIfStatusEntry OBJECT-TYPE
|
|
SYNTAX DPoeIfStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry consists of PoE status for a port."
|
|
INDEX { pethMainPseGroupIndex,pethPsePortIndex }
|
|
::= { dPoeIfStatusTable 1 }
|
|
|
|
DPoeIfStatusEntry ::= SEQUENCE {
|
|
dPoeIfDetectStatus INTEGER,
|
|
dPoeIfFaultyType INTEGER
|
|
}
|
|
|
|
dPoeIfDetectStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
searching(2),
|
|
requesting(3),
|
|
delivering(4),
|
|
faulty(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the operational status of the port PD detection.
|
|
disabled(1) - PSE function is disabled.
|
|
searching(2) - Remote PD is not connected.
|
|
requesting(3) - Remote PD is inserted, but the PSE doesn't provide power yet.
|
|
delivering(4) - Remote PD is now powering by PoE system.
|
|
faulty(5) - Device detection or a powered device is in a faulty state.
|
|
"
|
|
::= { dPoeIfStatusEntry 1 }
|
|
|
|
dPoeIfFaultyType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(0),
|
|
mpsAbsent(1),
|
|
pdShort(2),
|
|
overload(3),
|
|
powerDenied(4),
|
|
thermalShutdown(5),
|
|
startupFailure(6),
|
|
classificationFailure(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the specific faulty type. It is meaningful
|
|
only when dPoeIfDetectStatus object is 'faulty'.
|
|
notApplicable(0) - indicates this object is meaningless, e.g. the
|
|
dPoeIfDetectStatus is not 'faulty'.
|
|
mpsAbsent(1) - indicates MPS(Maintain Power Signature) Absent
|
|
pdShort(2) - indicates PD Short
|
|
overload(3) - indicates Overload
|
|
powerDenied(4) - indicates Power Denied
|
|
thermalShutdown(5)- indicates Thermal Shutdown
|
|
startupFailure(6) - indicates Startup Failure
|
|
classificationFailure(7) - indicates Classification Failure(IEEE 802.3at)
|
|
"
|
|
::= { dPoeIfStatusEntry 2 }
|
|
|
|
------------------------------------------------------------------------------------------------------
|
|
dPoeIfMeasurementTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DPoEIfMeasurementEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table consists of a list of POE measurement
|
|
information for ports."
|
|
::= { dPoeIfInfoObjects 2 }
|
|
|
|
dPoeIfMeasurementEntry OBJECT-TYPE
|
|
SYNTAX DPoEIfMeasurementEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry consists of PoE measurement information of a port."
|
|
INDEX {
|
|
pethMainPseGroupIndex,
|
|
pethPsePortIndex
|
|
}
|
|
::= { dPoeIfMeasurementTable 1 }
|
|
|
|
DPoEIfMeasurementEntry ::= SEQUENCE {
|
|
dPoeIfVoltage Integer32,
|
|
dPoeIfCurrent Integer32,
|
|
dPoeIfTemperature Integer32,
|
|
dPoeIfPower Integer32
|
|
}
|
|
|
|
dPoeIfVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "millivolts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the voltage of the port in millivolts."
|
|
::= { dPoeIfMeasurementEntry 1 }
|
|
|
|
dPoeIfCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "milliamperes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the current of port in milliamperes."
|
|
::= { dPoeIfMeasurementEntry 2 }
|
|
|
|
dPoeIfTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Degree Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the temperature of port in degrees centigrade."
|
|
::= { dPoeIfMeasurementEntry 3 }
|
|
|
|
dPoeIfPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates consumption power of port in milliwatts."
|
|
::= { dPoeIfMeasurementEntry 4 }
|
|
|
|
---------------------------------------------------------------------------------
|
|
-- Add a new table for SNR-20170223-001(ASV2.1)(PD alive check)
|
|
---------------------------------------------------------------------------------
|
|
dPoeIfPdAliveCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DPoeIfPdAliveCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table consists of a list of configuration for the PD
|
|
alive check function for ports.
|
|
The PD alive check feature provides the solution for
|
|
PD device that has the stop working or no response
|
|
problem via Ping mechanism.
|
|
Detailed Process:
|
|
The detailed processes are described as follows:
|
|
1. The system needs to periodically monitor the
|
|
specific PD by using Ping function. If there is no
|
|
response, system takes one of the following actions:
|
|
(1) Reset: Switch resets (disable then enable) PoE
|
|
power on the port which connects to a PD under monitoring.
|
|
(2) Notify: Switch sends logs and traps to notify the administrator.
|
|
(3) Both: Switch sends logs and traps, and resets the PoE port power.
|
|
2. The system should implement the retry mechanism to check
|
|
PD aliveness, hence the system will reset the PoE port power
|
|
feeding after the retry by using Ping without any response from a PD.
|
|
3. If the action is Reset or Both, the system needs
|
|
to wait for PD recovery from rebooting and then executes
|
|
the Ping function again. Besides, the waiting time can
|
|
be configured by users.
|
|
4. If PoE schedule (time range) function is configured
|
|
on the port which enables the PD Alive Check function,
|
|
the time range function has the top priority, and
|
|
therefore PD Alive Check function will not work
|
|
while PoE time range function is still active.
|
|
5. This function only takes effect on PoE enabled
|
|
port with power feeding.
|
|
|
|
Note: It is required to setup IP settings properly that
|
|
the PD can be reachable for Ping, otherwise this function
|
|
cannot work as expected.
|
|
|
|
Limitation
|
|
1. Support Ping Function: If the PD does not support ICMP,
|
|
this function cannot work normally.
|
|
2. Direct-Connected PD: The Reset Action can only work on
|
|
the direct-connected PD. If the PD is not connected directly,
|
|
the Reset Action may not work as expected.
|
|
3. PD Also Acts as PSE: If the direct-connected PD is also a PSE,
|
|
all the next level PDs connect to this PSE will be power cycling
|
|
whenever PD Alive Check function takes effect on 'Reset' or 'Both' Action."
|
|
::= { dPoeIfObjects 3 }
|
|
|
|
dPoeIfPdAliveCfgEntry OBJECT-TYPE
|
|
SYNTAX DPoeIfPdAliveCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry contains configuration for PD alive check on a port."
|
|
INDEX {
|
|
pethMainPseGroupIndex,
|
|
pethPsePortIndex
|
|
}
|
|
::= { dPoeIfPdAliveCfgTable 1 }
|
|
|
|
DPoeIfPdAliveCfgEntry ::= SEQUENCE {
|
|
dPoeIfPdAliveCfgState INTEGER,
|
|
dPoeIfPdAliveCfgPdIpType InetAddressType,
|
|
dPoeIfPdAliveCfgPdIpAddr InetAddress,
|
|
dPoeIfPdAliveCfgInterval Unsigned32,
|
|
dPoeIfPdAliveCfgRetry Unsigned32,
|
|
dPoeIfPdAliveCfgWaitTime Unsigned32,
|
|
dPoeIfPdAliveCfgAction INTEGER
|
|
}
|
|
|
|
dPoeIfPdAliveCfgState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the the PD alive function sate.
|
|
enabled - Enable the PD alive check function
|
|
disabled - Disable the PD alive check function.
|
|
|
|
"
|
|
DEFVAL { disabled }
|
|
::= { dPoeIfPdAliveCfgEntry 1 }
|
|
|
|
dPoeIfPdAliveCfgPdIpType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the IP address type of the target PD."
|
|
::= { dPoeIfPdAliveCfgEntry 2 }
|
|
|
|
dPoeIfPdAliveCfgPdIpAddr OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the IP address of the target PD."
|
|
::= { dPoeIfPdAliveCfgEntry 3 }
|
|
|
|
dPoeIfPdAliveCfgInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (10..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the time interval for system
|
|
issues ping request to detect the target PD.
|
|
The valid range for interval time is 10s to 300s."
|
|
DEFVAL { 30 }
|
|
::= { dPoeIfPdAliveCfgEntry 4 }
|
|
|
|
dPoeIfPdAliveCfgRetry OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..5)
|
|
UNITS "times"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the retry count of ping
|
|
request when PD has no response.
|
|
The valid range for retry count is 0 to 5 times."
|
|
DEFVAL { 2}
|
|
::= { dPoeIfPdAliveCfgEntry 5 }
|
|
|
|
|
|
dPoeIfPdAliveCfgWaitTime OBJECT-TYPE
|
|
SYNTAX Unsigned32 (30..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the waiting time for PD reboot.
|
|
The valid range for waiting time is 30s to 300s."
|
|
DEFVAL { 90 }
|
|
::= { dPoeIfPdAliveCfgEntry 6 }
|
|
|
|
dPoeIfPdAliveCfgAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reset(1),
|
|
notify(2),
|
|
both(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the action when PD doesn't reply the ping request.
|
|
reset- System will reset the PoE port state .
|
|
notify- System will send log and trap to notify the administrator.
|
|
both- System will send log and trap first and reset the PoE port state."
|
|
DEFVAL { both }
|
|
::= { dPoeIfPdAliveCfgEntry 7 }
|
|
|
|
-- *****************************************************************************
|
|
-- MIB Notifications
|
|
-- *****************************************************************************
|
|
dPoeIfPowerDeniedNotification NOTIFICATION-TYPE
|
|
OBJECTS { pethPsePortPowerDeniedCounter }
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates if PSE state diagram enters
|
|
the state POWER_DENIED.
|
|
At least 500 msec must elapse between notifications
|
|
being emitted by the same object instance."
|
|
::= { dPoeMIBNotifications 1 }
|
|
|
|
dPoeIfPowerOverLoadNotification NOTIFICATION-TYPE
|
|
OBJECTS { pethPsePortOverLoadCounter }
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates if PSE state diagram enters
|
|
the state ERROR_DELAY_OVER.
|
|
At least 500 msec must elapse between notifications
|
|
being emitted by the same object instance."
|
|
::= { dPoeMIBNotifications 2 }
|
|
|
|
dPoeIfPowerShortCircuitNotification NOTIFICATION-TYPE
|
|
OBJECTS { pethPsePortShortCounter }
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates if PSE state diagram enters
|
|
the state ERROR_DELAY_SHORT.
|
|
At least 500 msec must elapse between notifications
|
|
being emitted by the same object instance."
|
|
::= { dPoeMIBNotifications 3 }
|
|
|
|
dPoeIfPdAliveFailOccurNotification NOTIFICATION-TYPE
|
|
OBJECTS { pethMainPseGroupIndex,
|
|
pethPsePortIndex,
|
|
dPoeIfPdAliveCfgPdIpType,
|
|
dPoeIfPdAliveCfgPdIpAddr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates if the PD device has
|
|
the stop working or no response problem."
|
|
::= { dPoeMIBNotifications 4 }
|
|
|
|
-- *****************************************************************************
|
|
-- MIB Conformance statements
|
|
-- *****************************************************************************
|
|
dPoeMIBCompliances OBJECT IDENTIFIER ::= { dPoeMIBConformance 1 }
|
|
|
|
dPoeMIBGroups OBJECT IDENTIFIER ::= { dPoeMIBConformance 2 }
|
|
dPoeMIBCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement the
|
|
DLINKSW-POE-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
dPoeGroupCfgGroup,
|
|
dPoeIfCfgGroup,
|
|
dPoeGroupInfoGroup,
|
|
dPoeIfInfoGroup,
|
|
dPoeIfErrorStateNotificationGroup,
|
|
dPoeIfPdAliveCfgGroup
|
|
}
|
|
|
|
::= { dPoeMIBCompliances 1 }
|
|
|
|
dPoeGroupCfgGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dPoeGroupPolicyPreempt,
|
|
dPoeGroupIfLedMode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects to configure or display the group-specific PoE information."
|
|
::= { dPoeMIBGroups 1 }
|
|
|
|
dPoeIfCfgGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dPoeGroupClearIfStatistic,
|
|
dPoeIfState,
|
|
dPoeIfMaxPower,
|
|
dPoeIfTimeRange,
|
|
dPoeIfLegacyPdEnabled
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects configure or display the ports information."
|
|
::= { dPoeMIBGroups 2 }
|
|
|
|
dPoeGroupInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dPoeGroupMaxPorts,
|
|
dPoeGroupHWVersion,
|
|
dPoeGroupSWVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects display the groups information."
|
|
::= { dPoeMIBGroups 3 }
|
|
|
|
dPoeIfInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dPoeIfDetectStatus,
|
|
dPoeIfFaultyType,
|
|
dPoeIfVoltage,
|
|
dPoeIfCurrent,
|
|
dPoeIfTemperature,
|
|
dPoeIfPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects display the ports information."
|
|
::= { dPoeMIBGroups 4 }
|
|
|
|
dPoeIfErrorStateNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { dPoeIfPowerDeniedNotification,
|
|
dPoeIfPowerOverLoadNotification,
|
|
dPoeIfPowerShortCircuitNotification
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "A collection of objects provides ports error state notifications."
|
|
::= { dPoeMIBGroups 5 }
|
|
|
|
dPoeIfPdAliveCfgGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dPoeIfPdAliveCfgState,
|
|
dPoeIfPdAliveCfgPdIpType,
|
|
dPoeIfPdAliveCfgPdIpAddr,
|
|
dPoeIfPdAliveCfgInterval,
|
|
dPoeIfPdAliveCfgRetry,
|
|
dPoeIfPdAliveCfgWaitTime,
|
|
dPoeIfPdAliveCfgAction
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects display the PD alive check configuration."
|
|
::= { dPoeMIBGroups 6 }
|
|
|
|