-- File Name : HORIZON-IDU-MIB.mib
|
||
-- Version : 1.0.0
|
||
-- Date : April 16th, 2008
|
||
-- Author : DragonWave Inc.
|
||
|
||
DRAGONWAVE-HORIZON-IDU-MIB DEFINITIONS ::= BEGIN
|
||
IMPORTS
|
||
Counter, Gauge,TimeTicks
|
||
FROM RFC1155-SMI
|
||
snmp
|
||
FROM SNMPv2-MIB
|
||
OBJECT-TYPE, ifIndex
|
||
FROM IF-MIB
|
||
horizon
|
||
FROM HORIZON-MIB;
|
||
|
||
PhysAddress ::= OCTET STRING
|
||
|
||
DisplayString ::= OCTET STRING
|
||
|
||
-- Important!! For HP OpenView, the following OID definition for ISO must be commented out,
|
||
-- otherwise it won't compile. HP openView has already defined ISO.
|
||
|
||
-- iso OBJECT IDENTIFIER ::= { 1 }
|
||
|
||
|
||
horizonIdu OBJECT IDENTIFIER
|
||
::= { horizon 3 }
|
||
|
||
--
|
||
-- Node definitions
|
||
--
|
||
|
||
hzIduSystem OBJECT IDENTIFIER
|
||
::= { horizonIdu 1 }
|
||
|
||
hzIduAuthentication OBJECT IDENTIFIER
|
||
::= { horizonIdu 2 }
|
||
|
||
hzIduNetworkManagement OBJECT IDENTIFIER
|
||
::= { horizonIdu 3 }
|
||
|
||
hzIduNetworkInterface OBJECT IDENTIFIER
|
||
::= { horizonIdu 4 }
|
||
|
||
hzIduWirelessInterface OBJECT IDENTIFIER
|
||
::= { horizonIdu 5 }
|
||
|
||
hzIduCalendar OBJECT IDENTIFIER
|
||
::= { horizonIdu 6 }
|
||
|
||
hzIduAlarms OBJECT IDENTIFIER
|
||
::= { horizonIdu 7 }
|
||
|
||
hzIduTrapConfig OBJECT IDENTIFIER
|
||
::= { horizonIdu 8 }
|
||
|
||
hzIduSnmp OBJECT IDENTIFIER
|
||
::= { horizonIdu 9 }
|
||
|
||
hzIduManagementSessions OBJECT IDENTIFIER
|
||
::= { horizonIdu 10 }
|
||
|
||
hzIduHttp OBJECT IDENTIFIER
|
||
::= { horizonIdu 11 }
|
||
|
||
hzIduQos OBJECT IDENTIFIER
|
||
::= { horizonIdu 12 }
|
||
|
||
hzIduRapidLinkShutdown OBJECT IDENTIFIER
|
||
::= { horizonIdu 13 }
|
||
|
||
hzIduSntp OBJECT IDENTIFIER
|
||
::= { horizonIdu 14 }
|
||
|
||
hzIduLogs OBJECT IDENTIFIER
|
||
::= { horizonIdu 15 }
|
||
|
||
hzIduRadius OBJECT IDENTIFIER
|
||
::= { horizonIdu 16 }
|
||
|
||
-- -------------
|
||
-- hzIduSystem
|
||
-- -------------
|
||
|
||
hzIduSysGeneral OBJECT IDENTIFIER
|
||
::= { hzIduSystem 1 }
|
||
hzIduSysUpgradeSpeed OBJECT IDENTIFIER
|
||
::= { hzIduSystem 2 }
|
||
hzIduSysDowngradeSpeed OBJECT IDENTIFIER
|
||
::= { hzIduSystem 3 }
|
||
hzIduSysUpgradeWirelessPorts OBJECT IDENTIFIER
|
||
::= { hzIduSystem 4 }
|
||
hzIduSysSpeed OBJECT IDENTIFIER
|
||
::= { hzIduSystem 5 }
|
||
hzIduInventory OBJECT IDENTIFIER
|
||
::= { hzIduSystem 6 }
|
||
hzIduAtpc OBJECT IDENTIFIER
|
||
::= { hzIduSystem 7 }
|
||
hzIduAam OBJECT IDENTIFIER
|
||
::= { hzIduSystem 8 }
|
||
hzIduPeerSysInfo OBJECT IDENTIFIER
|
||
::= { hzIduSystem 9 }
|
||
|
||
|
||
|
||
-- ----------------------------
|
||
-- hzIduGeneral
|
||
-- ----------------------------
|
||
|
||
hzIduResetSystem OBJECT-TYPE
|
||
SYNTAX INTEGER { reset ( 1 ) }
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Writing '1' to this object resets the NIC, Modem, and radio."
|
||
::= { hzIduSysGeneral 1 }
|
||
|
||
hzIduSaveMIB OBJECT-TYPE
|
||
SYNTAX INTEGER { save ( 1 ) }
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Writing '1' or 'save' to this object save all MIB values."
|
||
|
||
::= { hzIduSysGeneral 2 }
|
||
|
||
hzIduOperStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { up ( 1 ) , down ( 2 ) , testing ( 3 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current operational state of the system.
|
||
Testing indicates that no operational packets can be passed."
|
||
::= { hzIduSysGeneral 3 }
|
||
|
||
hzIduAirInterfaceEncryption OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "OBSOLETE. This enables encryption on the air interface. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduSysGeneral 4 }
|
||
|
||
hzIduSystemCapacityOption OBJECT-TYPE
|
||
SYNTAX INTEGER { singleModem-singleRadio ( 1 ),
|
||
multiModem-singleRadio ( 2 ),
|
||
multiModem-multiRadio ( 3 ),
|
||
singleModem-redundancy ( 4 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Sets the system capacity options. There are four options:
|
||
Select 'singleModem-singleRadio' for a 400Mbps system.
|
||
Select 'multiModem-singleRadio' for 800Mbps when the system is equipped with an internal or external IF Coupler.
|
||
Select 'multiModem-multiRadio' for 800Mbps when the system is equipped with two radios connected to a Dual Polarization Radio Mount (DPRM).
|
||
Select 'singleModem-redundancy' to provide a redundant 400Mbps link using a Redundant Dual Radio Mount (RDRM).
|
||
|
||
Notes:
|
||
Setting the system capacity to 'singleModem-redundancy will fail if the primary path has not been set to either wireless_port1 or wireless_port2.
|
||
Setting the system capacity to 'multiModem-multiRadio' will set the transmit power of wireless_port2 to the same transmite power as wireless_port1."
|
||
DEFVAL { singleModem-singleRadio }
|
||
::= { hzIduSysGeneral 5 }
|
||
|
||
|
||
-- ----------------------------
|
||
-- hzIduSysUpgradeSpeed
|
||
-- ----------------------------
|
||
|
||
hzIduLicensedSpeedUpgradeSpeedAndKey OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Enter your apngFLEX key here along with the maximum speed for that key to upgrade the FLEX system.
|
||
|
||
Format: [speed] [key]
|
||
Example: 800 abc123"
|
||
::= { hzIduSysUpgradeSpeed 1 }
|
||
|
||
hzIduLicensedSpeedChanges OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This object indicates the number of times the licensed speed has been changed successfully. It is used when generating new license keys for your system."
|
||
::= { hzIduSysUpgradeSpeed 2 }
|
||
|
||
-- ----------------------------
|
||
-- hzIduSysDowngradeSpeed
|
||
-- ----------------------------
|
||
|
||
hzIduLicensedSpeedDowngradeSpeed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Reduce your licensed speed by entering a speed to this write-only object and take note of the generated key in hzIduDowngradeLicensedSpeedKey.
|
||
|
||
Format: [speed]
|
||
Example: 200"
|
||
::= { hzIduSysDowngradeSpeed 1 }
|
||
|
||
hzIduLicensedSpeedCountUsedForKey OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This object indicates the number of times the licensed speed has been changed successfully. It is used when generating new license keys for your system."
|
||
::= { hzIduSysDowngradeSpeed 2 }
|
||
|
||
hzIduLicensedSpeedDowngradeKey OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This read-only object will show a 'key' after successfully downgrading the license speed."
|
||
::= { hzIduSysDowngradeSpeed 3 }
|
||
|
||
-- ----------------------------
|
||
-- hzIduSysUpgradeWirelessPorts
|
||
-- ----------------------------
|
||
|
||
hzIduLicensedWirelessPortsUpgradeKey OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Hardware upgrade license key. Upgrade the number of active wireless ports by setting a valid license key."
|
||
::= { hzIduSysUpgradeWirelessPorts 1 }
|
||
|
||
hzIduLicensedWirelessPortsChanges OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This object indicates the number of times the wireless port count has been changed successfully. It is used when generating new license keys for your system. Currently, there is no SNMP object for downgrading the number of wireless ports."
|
||
::= { hzIduSysUpgradeWirelessPorts 2 }
|
||
|
||
|
||
-- ----------------------------
|
||
-- hzIduSysSpeed
|
||
-- ----------------------------
|
||
|
||
hzIduSystemCurrentSpeed OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..1000 )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Changes the working speed of the horizon. Writes are only valid if system is a FLEX. Due to backwards compatibility issue, 0 value should be treated as 0 Mbps."
|
||
::= { hzIduSysSpeed 1 }
|
||
|
||
hzIduSystemLicensedSpeed OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..1000 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the maximum speed that this system can operate at. Due to backwards compatibility issue, 0 value should be treated as 0 Mbps."
|
||
::= { hzIduSysSpeed 2 }
|
||
|
||
-- --------------------------------------------------------------------------
|
||
-- The following System Modes were taken from the frequency file generated
|
||
-- with the following version and date:
|
||
-- FrequencyFilePartNumber :VDD-67-001112-01
|
||
-- Version :1.0.95
|
||
-- Date :10-Mar-2008
|
||
-- --------------------------------------------------------------------------
|
||
hzIduSystemMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
cw-test(1),
|
||
hz50-67-qpsk(5),
|
||
hz50-110-16qam(6),
|
||
hz50-171-32qam(7),
|
||
hz50-215-64qam(8),
|
||
hz50-271-128qam(9),
|
||
hz50-322-256qam(10),
|
||
hz50-364-256qam(40), -- note out of numerical order
|
||
hz50-371-256qam(11),
|
||
hz56-65-qpsk(12),
|
||
hz56-111-16qam(13),
|
||
hz56-216-32qam(14),
|
||
hz56-290-128qam(15),
|
||
hz56-385-256qam(16),
|
||
hz28-37-qpsk(17),
|
||
hz28-48-qpsk(18),
|
||
hz28-71-16qam(19),
|
||
hz28-100-32qam(20),
|
||
hz28-144-128qam(21),
|
||
hz28-190-256qam(22),
|
||
hz14-23-qpsk(23),
|
||
hz14-36-16qam(24),
|
||
hz14-47-32qam(25),
|
||
hz14-70-128qam(26),
|
||
hz14-95-256qam(27),
|
||
hz40-57-qpsk(28),
|
||
hz40-58-qpsk(29),
|
||
hz40-110-32qam(30),
|
||
hz40-111-16qam(31),
|
||
hz40-142-32qam(32),
|
||
hz40-181-64qam(33),
|
||
hz40-200-128qam(34),
|
||
hz40-212-128qam(35),
|
||
hz40-277-256qam(36),
|
||
hz30-107-32qam(37),
|
||
hz30-165-128qam(38),
|
||
hz30-212-256qam(39)
|
||
-- hz50-364-256qam(40) relocated with hz50
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the specific type of system this is."
|
||
::= { hzIduSysSpeed 3 }
|
||
|
||
|
||
-- ----------------------------
|
||
-- hzIduInventory
|
||
-- ----------------------------
|
||
|
||
hzIduHwInventory OBJECT IDENTIFIER
|
||
::= { hzIduInventory 1 }
|
||
hzIduSwInventory OBJECT IDENTIFIER
|
||
::= { hzIduInventory 2 }
|
||
|
||
-- ----------------------------
|
||
-- hzIduHwInventory
|
||
-- ----------------------------
|
||
hzIduFrequencyFilePartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing Part Number of the Frequency File"
|
||
::= { hzIduHwInventory 1 }
|
||
|
||
hzIduUnitSerialNo OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing Serial Number of the Unit."
|
||
::= { hzIduHwInventory 2 }
|
||
|
||
hzIduUnitAssemblylNo OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing the Assembly Number of the Unit."
|
||
::= { hzIduHwInventory 3 }
|
||
|
||
hzIduIfSerialNo1 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing Serial no of IF 1."
|
||
::= { hzIduHwInventory 4 }
|
||
|
||
hzIduIfSerialNo2 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing Serial no of IF 2."
|
||
::= { hzIduHwInventory 5 }
|
||
|
||
hzIduIfAssemblylNo1 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing assembly no of IF 1."
|
||
::= { hzIduHwInventory 6 }
|
||
|
||
hzIduIfAssemblylNo2 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing assembly no of IF 2."
|
||
::= { hzIduHwInventory 7 }
|
||
|
||
hzIduNccSerialNo OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing Serial no of the NCC."
|
||
::= { hzIduHwInventory 10 }
|
||
|
||
hzIduNccAssemblylNo OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing assembly no of the NCC."
|
||
::= { hzIduHwInventory 11 }
|
||
|
||
hzIduRadio1SerialNo OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing the serial number of radio 1"
|
||
::= { hzIduHwInventory 12 }
|
||
|
||
hzIduRadio2SerialNo OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing the serial number of radio 2 if configured"
|
||
::= { hzIduHwInventory 13 }
|
||
|
||
hzIduRadio1HardwareId OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing the hardware id of radio 1"
|
||
::= { hzIduHwInventory 14 }
|
||
|
||
hzIduRadio2HardwareId OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing the hardware id of radio 2 if configured"
|
||
::= { hzIduHwInventory 15 }
|
||
|
||
hzIduInternalIFCouplerPresent OBJECT-TYPE
|
||
SYNTAX INTEGER { not-present ( 1 ) , present ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This attribute indicates if there is an internal IF Coupler card present."
|
||
::= { hzIduHwInventory 16 }
|
||
|
||
hzIduHwWirelessPortsLicensed OBJECT-TYPE
|
||
SYNTAX INTEGER ( 1..2 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The number of licensed wireless ports. Upgrade this to 2 ports by setting the hardware upgrade license key."
|
||
::= { hzIduHwInventory 17 }
|
||
|
||
-- ----------------------------
|
||
-- hzIduSwInventory
|
||
-- ----------------------------
|
||
|
||
hzIduSwInvSystemOmniVersionNo OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The version number of the Omni."
|
||
::= { hzIduSwInventory 1 }
|
||
|
||
hzIduSwInvModemOmniVersionNo OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The version number of the Modem FPGA."
|
||
::= { hzIduSwInventory 2 }
|
||
|
||
hzIduSwInvFrequencyFileVersionNo OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The version number of the FrequencyFile."
|
||
::= { hzIduSwInventory 3 }
|
||
|
||
hzIduSwInvMibVersionNo OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The version number of the MIB."
|
||
::= { hzIduSwInventory 4 }
|
||
|
||
hzIduSwInvRadio1FirmwareVersionNo OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The version of radio 1 firmware."
|
||
::= { hzIduSwInventory 5 }
|
||
|
||
hzIduSwInvRadio2FirmwareVersionNo OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The version of radio 2 firmware."
|
||
::= { hzIduSwInventory 6 }
|
||
|
||
-- ----------------------------
|
||
-- hzIduAtpc
|
||
-- ----------------------------
|
||
hzIduAtpcEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates whether Automatic Transmit Power Control (ATPC) is enabled."
|
||
DEFVAL { disabled }
|
||
::= { hzIduAtpc 1 }
|
||
|
||
hzIduAtpcStatus OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the actual condition of ATPC:
|
||
Enabled <20> if config is on and no issues
|
||
|
||
Auto-Disabled <20> if ATPC coordinated power condition, AAM triggered, or radio loss of link
|
||
|
||
Disabled-manual <20> if config set to off"
|
||
|
||
::= { hzIduAtpc 2 }
|
||
|
||
hzIduAtpcCoordinatedPower OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "
|
||
The Coordinated Power can be enabled by specifying the coordinated power status and coordinated power offset in a string with the following format (without the single quotes):
|
||
|
||
'<on [offset] | off>'
|
||
|
||
The offset can optionally be specified after the 'on' string and after a single space and can be be between 0.0 and 10.0 inclusive. The 'offset' is represented in dBm and indicates the offset below TxPower. The accuracy is limited to tenths of dBm so an offset of 9.99 is recognized as 9.9 dBm.
|
||
|
||
Examples: 'on 5.5' or 'off'"
|
||
|
||
::= { hzIduAtpc 3 }
|
||
|
||
|
||
-- ----------------------------
|
||
-- hzIduAam
|
||
-- ----------------------------
|
||
hzIduAamStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Read or set the Automatic Adaptive Modulation (AAM) as 'on' or 'off'."
|
||
DEFVAL { disabled }
|
||
::= { hzIduAam 1 }
|
||
|
||
hzIduAamDiagnostics OBJECT IDENTIFIER
|
||
::= { hzIduAam 2 }
|
||
|
||
-- ----------------------------
|
||
-- hzIduAamDiagnostics
|
||
-- ----------------------------
|
||
|
||
hzIduAamDiagnose OBJECT-TYPE
|
||
SYNTAX INTEGER { up ( 1 ) , down ( 2 ) }
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This write-only object accepts either 'up' or 'down' to diagnose whether the modulation speed can be increased or decreased respectively. Poll the hzIduAamDiagnosticResult object to determine the results."
|
||
::= { hzIduAamDiagnostics 1 }
|
||
|
||
hzIduAamDiagnosticResult OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The result from AAM Diagnostic is read from this object."
|
||
::= { hzIduAamDiagnostics 2 }
|
||
|
||
-- ----------------------
|
||
-- hzIduPeerSysInfo
|
||
-- ---------------------
|
||
hzIduPeerMacAddress OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The MAC Address of the peer network interface card."
|
||
::= { hzIduPeerSysInfo 1 }
|
||
|
||
hzIduPeerIpAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The IP Address of the peer network interface card."
|
||
::= { hzIduPeerSysInfo 2 }
|
||
|
||
hzIduPeerSubnetMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The subnet mask for the peer network interface card."
|
||
::= { hzIduPeerSysInfo 3 }
|
||
|
||
--- ----------------------------
|
||
-- hzIduAuthentication
|
||
-- ----------------------------
|
||
hzIduUniquePeerAuthenticationKey OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 34 ) )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The serial number of the peer node that this node will communicate with.
|
||
This is only used when authentication mode is set to unique."
|
||
::= { hzIduAuthentication 1 }
|
||
|
||
hzIduPeerDetectedSerialNumber OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The serial number of the peer node that the system is presently communicating
|
||
with. This is only used when authentication is set to unique."
|
||
::= { hzIduAuthentication 2 }
|
||
|
||
hzIduAuthenticationMode OBJECT-TYPE
|
||
SYNTAX INTEGER { none ( 1 ) , unique ( 2 ) , group ( 3 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "This sets the authentication mode for the system.If configured for unique
|
||
authentication, an horizon node only exchanges user traffic with one other
|
||
horizon node. The serial number is used in this case.
|
||
|
||
If configured for group authentication, an horizon node exchanges user
|
||
traffic with another horizon node of the same group and uses the
|
||
authentication keys."
|
||
DEFVAL { none }
|
||
::= { hzIduAuthentication 3 }
|
||
|
||
hzIduAuthenticationFailureAction OBJECT-TYPE
|
||
SYNTAX INTEGER { blockTraffic ( 1 ) , passTraffic ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "This sets the authentication failure action for the system.
|
||
|
||
Block traffic will block all user traffic including remote
|
||
management access. Pass traffic will allow all user traffic
|
||
to be sent and recieved"
|
||
DEFVAL { blockTraffic }
|
||
::= { hzIduAuthentication 4 }
|
||
|
||
hzIduPeerAuthenticationStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { notAuthenticated ( 1 ) , authenticated ( 2 ) ,explicitAuthenticationFailure ( 3 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies the current authentication status of the system.
|
||
|
||
Authenticated means authentication is on and the system
|
||
has been authenticated, notAuthenticated means authentication
|
||
is off or the system has not communicated yet with the other node,
|
||
explicit authentication failure means authentication is on and
|
||
authentication has failed"
|
||
::= { hzIduAuthentication 5 }
|
||
--
|
||
-- NetworkManagement
|
||
--
|
||
hzIduMacAddress OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The MAC Address of the network interface card."
|
||
::= { hzIduNetworkManagement 1 }
|
||
|
||
hzIduNetworkManagementInterface OBJECT-TYPE
|
||
SYNTAX INTEGER { port1 ( 1 ) , port2 ( 2 ), port2Extended(3) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Describes the network management interface connection options."
|
||
::= { hzIduNetworkManagement 2 }
|
||
|
||
|
||
hzIduIpAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The IP Address of the network interface card."
|
||
::= { hzIduNetworkManagement 3 }
|
||
|
||
hzIduSubnetMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The subnet mask for the network interface card."
|
||
::= { hzIduNetworkManagement 4 }
|
||
|
||
hzIduDefaultGateway OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The default gateway for the network interface card"
|
||
::= { hzIduNetworkManagement 5 }
|
||
|
||
hzIduTelnetAccessMode OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates whether Telnet access is allowed."
|
||
DEFVAL { enabled }
|
||
::= { hzIduNetworkManagement 6 }
|
||
|
||
hzIduSshAccessMode OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates whether ssh access is allowed."
|
||
DEFVAL { enabled }
|
||
::= { hzIduNetworkManagement 7 }
|
||
|
||
hzIduVlanTagEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates whether VLAN tagging is enabled."
|
||
DEFVAL { disabled }
|
||
::= { hzIduNetworkManagement 8 }
|
||
|
||
hzIduVlanTagId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION ""
|
||
DEFVAL { 0 }
|
||
::= { hzIduNetworkManagement 9 }
|
||
|
||
hzIduVlanTagPriority OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION ""
|
||
DEFVAL { 0 }
|
||
::= { hzIduNetworkManagement 10 }
|
||
|
||
|
||
--
|
||
-- NETWORK CARD INFORMATION
|
||
--
|
||
|
||
|
||
|
||
hzIduEnetPort1 OBJECT IDENTIFIER
|
||
::= { hzIduNetworkInterface 1 }
|
||
hzIduEnetPort2 OBJECT IDENTIFIER
|
||
::= { hzIduNetworkInterface 2 }
|
||
|
||
hzIduEnetPort2Description OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Describes the functionality of the port2"
|
||
DEFVAL { on }
|
||
::= { hzIduEnetPort2 1 }
|
||
|
||
|
||
hzIduEnetPort2Config OBJECT IDENTIFIER
|
||
::= { hzIduEnetPort2 2 }
|
||
hzIduEnetPort2Status OBJECT IDENTIFIER
|
||
::= { hzIduEnetPort2 3 }
|
||
hzIduEnetPort2Stats OBJECT IDENTIFIER
|
||
::= { hzIduEnetPort2 4 }
|
||
|
||
hzIduEnetPort1Description OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Describes the functionality of the port1"
|
||
DEFVAL { on }
|
||
::= { hzIduEnetPort1 1 }
|
||
|
||
|
||
hzIduEnetPort1Config OBJECT IDENTIFIER
|
||
::= { hzIduEnetPort1 2 }
|
||
hzIduEnetPort1Status OBJECT IDENTIFIER
|
||
::= { hzIduEnetPort1 3 }
|
||
hzIduEnetPort1Stats OBJECT IDENTIFIER
|
||
::= { hzIduEnetPort1 4 }
|
||
|
||
--
|
||
-- hzIduEnetPort2Config
|
||
--
|
||
|
||
hzIduEnetPort2AutoNegotiation OBJECT-TYPE
|
||
SYNTAX INTEGER { on ( 1 ) , off ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Turns auto-negotiation on or off for Ethernet Port2. Turning off results in the interface defaulting to 100BaseT, Full Duplex. "
|
||
DEFVAL { on }
|
||
::= { hzIduEnetPort2Config 1 }
|
||
|
||
hzIduEnetPort2Speed OBJECT-TYPE
|
||
SYNTAX INTEGER { x10M( 1 ) , x100M( 2 ), x1000M( 3 ), auto(4) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Configure the port1 interface speed ."
|
||
::= { hzIduEnetPort2Config 2}
|
||
|
||
hzIduEnetPort2Duplex OBJECT-TYPE
|
||
SYNTAX INTEGER { full( 1 ) , half( 2 ), auto( 3 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Configure the port1 interface duplex."
|
||
::= { hzIduEnetPort2Config 3}
|
||
|
||
|
||
hzIduEnetPort2AdminState OBJECT-TYPE
|
||
SYNTAX INTEGER { on( 1 ) , off( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Configure the port2 shutdown media."
|
||
::= { hzIduEnetPort2Config 4}
|
||
|
||
--
|
||
-- Port2 STATUS
|
||
--
|
||
|
||
hzIduEnetPort2LinkStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { down ( 1 ) , up( 2 ) , invalid( 3 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the Port2 link status."
|
||
::= { hzIduEnetPort2Status 1}
|
||
|
||
|
||
|
||
hzIduEnetPort2AutoNegotiationStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { on( 1 ) , off( 2 ) ,invalid(3) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the Port2 AutoNegotiation status."
|
||
::= { hzIduEnetPort2Status 2}
|
||
|
||
|
||
hzIduEnetPort2SpeedStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { x10M( 1 ) , x100M( 2 ), x1000M( 3 ), auto(4) ,invalid(5)}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the Port2 interface speed status."
|
||
::= { hzIduEnetPort2Status 3}
|
||
|
||
|
||
hzIduEnetPort2DuplexStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { full( 1 ) , half( 2 ), auto( 3 ), invalid(4) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the Port2 interface duplex status."
|
||
::= { hzIduEnetPort2Status 4}
|
||
|
||
--
|
||
-- Port2 STATISTICS
|
||
--
|
||
|
||
hzIduEnetPort2TxFrames OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of Port2 frames sent."
|
||
::= { hzIduEnetPort2Stats 1 }
|
||
|
||
hzIduEnetPort2TxBytes OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of Port2 bytes sent."
|
||
::= { hzIduEnetPort2Stats 2 }
|
||
|
||
hzIduEnetPort2RxFrames OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of Port2 frames received."
|
||
::= { hzIduEnetPort2Stats 3 }
|
||
|
||
hzIduEnetPort2RxBytes OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of Port2 bytes received."
|
||
::= { hzIduEnetPort2Stats 4 }
|
||
|
||
hzIduEnetPort2RxFramesInErrors OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of Port2 frames received in error."
|
||
::= { hzIduEnetPort2Stats 5 }
|
||
|
||
hzIduEnetPort2RxFramesCrcErrors OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of CRC error frames received for Port2."
|
||
::= { hzIduEnetPort2Stats 6 }
|
||
|
||
|
||
--
|
||
-- PORT1 CONFIG
|
||
--
|
||
|
||
hzIduEnetPort1AutoNegotiation OBJECT-TYPE
|
||
SYNTAX INTEGER { on( 1 ) , off ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Turns auto-negotiation on or off for Ethernet Port1. Turning off results in the interface defaulting to 100BaseT, Full Duplex. "
|
||
DEFVAL { on }
|
||
::= { hzIduEnetPort1Config 1 }
|
||
|
||
hzIduEnetPort1Speed OBJECT-TYPE
|
||
SYNTAX INTEGER { x10M( 1 ) , x100M( 2 ), x1000M( 3 ), auto(4) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Configure the port1 interface speed ."
|
||
::= { hzIduEnetPort1Config 2}
|
||
|
||
|
||
hzIduEnetPort1Duplex OBJECT-TYPE
|
||
SYNTAX INTEGER { full( 1 ) , half( 2 ), auto( 3 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Configure the port1 interface duplex."
|
||
::= { hzIduEnetPort1Config 3}
|
||
|
||
hzIduEnetPort1Media OBJECT-TYPE
|
||
SYNTAX INTEGER { copper( 1 ) , fiber( 2 ), auto( 3 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Configure the port1 interface media."
|
||
::= { hzIduEnetPort1Config 4}
|
||
|
||
hzIduEnetPort1AdminState OBJECT-TYPE
|
||
SYNTAX INTEGER { on( 1 ) , off( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Configure the port1 interface media."
|
||
::= { hzIduEnetPort1Config 5}
|
||
|
||
hzIduEnetPort1OpticalTransceiverState OBJECT-TYPE
|
||
SYNTAX INTEGER { on ( 1 ) , off ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "When it is on, optical transmitter for port1 is enabled. Otherwise optical transmitter is disabled."
|
||
DEFVAL { off }
|
||
::= { hzIduEnetPort1Config 6 }
|
||
|
||
hzIduEnetPort1PauseFrameEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "When PAUSE is enabled, port1 pause frames can be generated by the
|
||
system and the pause frames will flow toward the link partner
|
||
on the network. When PAUSE is not enabled,
|
||
no pause frames will be generated by the system. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduEnetPort1Config 7 }
|
||
|
||
|
||
hzIduEnetPort1MaxFrameSize OBJECT-TYPE
|
||
SYNTAX INTEGER ( 1600..9600 )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "For port1 the default maximum frame size is 1600 bytes. The settable
|
||
maximum frame size must be a multiple of 128. If the chosen
|
||
maximum frame size is not a multiple of 128, its closest
|
||
number which is a multiple of 128 is actually used. The
|
||
settable lowest maximum frame size is 1664, and the settable
|
||
highest maximum frame size is 9600. If the chosen maximum
|
||
frame size is out of this range, the default maximum frame
|
||
size of 1600 is used. "
|
||
DEFVAL { 1600 }
|
||
::= { hzIduEnetPort1Config 8 }
|
||
|
||
hzIduEnetPort1DroppedEnetFramesThresholdParameters OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "A read-write string: The threshold, in percent, and the number of seconds that it must exceed this threshold are programmed by the user. An example of the format of the string is as follows: '70 10'. The first parameter is the percentage of frames that are dropped, the second is the time in seconds that the threshold must be exceeded. The single quote marks i.e. ' ' are not used in the command."
|
||
::= { hzIduEnetPort1Config 9 }
|
||
|
||
hzIduEnetPort1BandwidthUtilizationThresholdParameters OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "A read-write string: The percentage of available bandwidth threshold and the number of seconds that it must exceed this threshold are programmed by the user. An example of the format of the string is as follows: '70 10'. The first parameter is the threshold point in percent, the number of seconds that the threshold must be exceeded. The single quote marks i.e. ' ' are not used in the command."
|
||
::= { hzIduEnetPort1Config 10 }
|
||
|
||
--
|
||
-- PORT1 STATUS
|
||
--
|
||
|
||
hzIduEnetPort1LinkStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { down ( 1 ) , up( 2 ) , invalid( 3 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the port1 link status."
|
||
::= { hzIduEnetPort1Status 1}
|
||
|
||
|
||
|
||
hzIduEnetPort1AutoNegotiationStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { on( 1 ) , off( 2 ),invalid(3) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the port1 AutoNegotiation status."
|
||
::= { hzIduEnetPort1Status 2}
|
||
|
||
|
||
hzIduEnetPort1SpeedStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { x10M( 1 ) , x100M( 2 ), x1000M( 3 ), auto(4) ,invalid(5)}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the port1 interface speed status."
|
||
::= { hzIduEnetPort1Status 3}
|
||
|
||
|
||
hzIduEnetPort1DuplexStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { full( 1 ) , half( 2 ), auto( 3 ) ,invalid(4)}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the port1 interface duplex status."
|
||
::= { hzIduEnetPort1Status 4}
|
||
|
||
hzIduEnetPort1MediaStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { copper( 1 ) , fiber( 2 ), auto( 3 ),invalid(4) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the port1 interface media status."
|
||
::= { hzIduEnetPort1Status 5}
|
||
|
||
--
|
||
-- PORT1 STATISTICS
|
||
--
|
||
|
||
hzIduEnetPort1TxFrames OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of port1 frames sent."
|
||
::= { hzIduEnetPort1Stats 1 }
|
||
|
||
hzIduEnetPort1TxBytes OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of port1 bytes sent."
|
||
::= { hzIduEnetPort1Stats 2 }
|
||
|
||
hzIduEnetPort1RxFrames OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of port1 frames received."
|
||
::= { hzIduEnetPort1Stats 3 }
|
||
|
||
hzIduEnetPort1RxBytes OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of port1 bytes received."
|
||
::= { hzIduEnetPort1Stats 4 }
|
||
|
||
hzIduEnetPort1RxFramesInErrors OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of port1 frames received in error."
|
||
::= { hzIduEnetPort1Stats 5 }
|
||
|
||
hzIduEnetPort1RxFramesCRCErrors OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of CRC error frames received for port1."
|
||
::= { hzIduEnetPort1Stats 6 }
|
||
|
||
hzIduEnetPort1BWUtilization OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The carried load over link capacity for port1."
|
||
::= { hzIduEnetPort1Stats 7 }
|
||
|
||
hzIduEnetPort1IngressDataRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The data rate coming into the ethernet for port1.
|
||
The data rate you see is multiplied by 100. e.g. A display
|
||
of 1530 is actually 15.30 Mpbs"
|
||
::= { hzIduEnetPort1Stats 8 }
|
||
|
||
hzIduEnetPort1EgressDataRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The data rate going out of the ethernet for port1.
|
||
The data rate you see is multiplied by 100. e.g. A display
|
||
of 1530 is actually 15.30 Mpbs."
|
||
::= { hzIduEnetPort1Stats 9 }
|
||
|
||
|
||
|
||
hzIduEnetPort1FramesInQueue1s OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of port1 frames passed through queue 1."
|
||
::= { hzIduEnetPort1Stats 10 }
|
||
|
||
hzIduEnetPort1FramesInQueue2s OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of port1 frames passed through queue 2."
|
||
::= { hzIduEnetPort1Stats 11 }
|
||
|
||
hzIduEnetPort1FramesInQueue3s OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of NIC frames passed through queue 3."
|
||
::= { hzIduEnetPort1Stats 12 }
|
||
|
||
hzIduEnetPort1FramesInQueue4s OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of NIC frames passed through queue 4."
|
||
::= { hzIduEnetPort1Stats 13 }
|
||
|
||
hzIduEnetPort1FramesInQueue1Discardeds OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of NIC frames received in queue 2 that
|
||
were discarded, but due to an error. One possible reason
|
||
is lack of buffer space."
|
||
::= { hzIduEnetPort1Stats 14 }
|
||
|
||
hzIduEnetPort1FramesInQueue2Discardeds OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of port1 frames received in queue 2 that
|
||
were discarded, but due to an error. One possible reason
|
||
is lack of buffer space."
|
||
::= { hzIduEnetPort1Stats 15 }
|
||
|
||
hzIduEnetPort1FramesInQueue3Discardeds OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of port1 frames received in queue 3 that
|
||
were discarded, but due to an error. One possible reason
|
||
is lack of buffer space."
|
||
::= { hzIduEnetPort1Stats 16 }
|
||
|
||
hzIduEnetPort1FramesInQueue4Discardeds OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of port1 frames received in queue 4 that
|
||
were discarded, but due to an error. One possible reason
|
||
is lack of buffer space."
|
||
::= { hzIduEnetPort1Stats 17 }
|
||
|
||
|
||
-- ----------------------------
|
||
-- hzIduWirelessInterface
|
||
-- ----------------------------
|
||
|
||
hzIduWirelessInterfaceNames OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterface 1 }
|
||
|
||
hzIduWirelessInterfaceModems OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterface 2 }
|
||
|
||
hzIduWirelessInterfaceIFCards OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterface 3 }
|
||
|
||
hzIduWirelessInterfaceRadios OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterface 4 }
|
||
|
||
hzIduWirelessInterfaceRadioFrequencies OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterface 5 }
|
||
|
||
hzIduWirelessInterfaceAntenna OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterface 6 }
|
||
|
||
hzIduWirelessInterfaceRedundancy OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterface 7 }
|
||
|
||
-- -----------------------------
|
||
-- hzIduWirelessInterfaceNames
|
||
-- -----------------------------
|
||
|
||
hzIduWirelessInterfaceNameTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduWirelessInterfaceNameEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of Wireless Interface Modems"
|
||
::= { hzIduWirelessInterfaceNames 1 }
|
||
|
||
hzIduWirelessInterfaceNameEntry OBJECT-TYPE
|
||
SYNTAX HzIduWirelessInterfaceNameEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A Wireless Interface Modem"
|
||
INDEX { hzIduWirelessInterfaceNameIndex }
|
||
::= { hzIduWirelessInterfaceNameTable 1 }
|
||
|
||
HzIduWirelessInterfaceNameEntry ::= SEQUENCE {
|
||
hzIduWirelessInterfaceNameIndex INTEGER,
|
||
hzIduWirelessInterfaceName DisplayString
|
||
}
|
||
|
||
hzIduWirelessInterfaceNameIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each interface. "
|
||
::= { hzIduWirelessInterfaceNameEntry 1 }
|
||
|
||
hzIduWirelessInterfaceName OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Describes the functionality of the Wireless Interface"
|
||
::= { hzIduWirelessInterfaceNameEntry 2 }
|
||
|
||
-- -----------------------------
|
||
-- hzIduWirelessInterfaceIFCards
|
||
-- -----------------------------
|
||
|
||
hzIduIntermediateFrequencyCardTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduIntermediateFrequencyCardEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of Wireless Interface Modems"
|
||
::= { hzIduWirelessInterfaceIFCards 1 }
|
||
|
||
hzIduIntermediateFrequencyCardEntry OBJECT-TYPE
|
||
SYNTAX HzIduIntermediateFrequencyCardEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A Wireless Interface Modem"
|
||
INDEX { hzIduIFCardIndex }
|
||
::= { hzIduIntermediateFrequencyCardTable 1 }
|
||
|
||
HzIduIntermediateFrequencyCardEntry ::= SEQUENCE {
|
||
hzIduIFCardIndex INTEGER,
|
||
hzIduIFCardTxSynthesizerLock INTEGER,
|
||
hzIduIFCardRxSynthesizerLock INTEGER
|
||
}
|
||
|
||
hzIduIFCardIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each interface. "
|
||
::= { hzIduIntermediateFrequencyCardEntry 1 }
|
||
|
||
hzIduIFCardTxSynthesizerLock OBJECT-TYPE
|
||
SYNTAX INTEGER { unlocked ( 1 ), locked ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates if the transmit synthesizer is locked."
|
||
::= { hzIduIntermediateFrequencyCardEntry 2 }
|
||
|
||
hzIduIFCardRxSynthesizerLock OBJECT-TYPE
|
||
SYNTAX INTEGER { unlocked ( 1 ), locked ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates if the receive synthesizer is locked."
|
||
::= { hzIduIntermediateFrequencyCardEntry 3 }
|
||
|
||
-- -----------------------------
|
||
-- hzIduWirelessInterfaceModems
|
||
-- -----------------------------
|
||
|
||
hzIduAggregatedWirelessPortStats OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterfaceModems 1 }
|
||
|
||
hzIduAggregatedWirelessPortTxFrames OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of Ethernet Combiner frames sent."
|
||
::= { hzIduAggregatedWirelessPortStats 1 }
|
||
|
||
hzIduAggregatedWirelessPortRxFramesOKs OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of good Ethernet Combiner frames received."
|
||
::= { hzIduAggregatedWirelessPortStats 2 }
|
||
|
||
hzIduAggregatedWirelessPortRxFrameErrors OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of Ethernet Combiner frames received in error."
|
||
::= { hzIduAggregatedWirelessPortStats 3 }
|
||
|
||
hzIduAggregatedWirelessPortRxFramesQueueDiscards OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of Ethernet Combiner frames in the queue that were discarded."
|
||
::= { hzIduAggregatedWirelessPortStats 4 }
|
||
|
||
-- ----------------
|
||
-- hzIduModemTable
|
||
-- ----------------
|
||
|
||
hzIduModemTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduModemEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of Wireless Interface Modems"
|
||
::= { hzIduWirelessInterfaceModems 2 }
|
||
|
||
hzIduModemEntry OBJECT-TYPE
|
||
SYNTAX HzIduModemEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A Wireless Interface Modem"
|
||
INDEX { hzIduModemIndex }
|
||
::= { hzIduModemTable 1 }
|
||
|
||
HzIduModemEntry ::= SEQUENCE {
|
||
hzIduModemIndex INTEGER,
|
||
hzIduModemOperStatus INTEGER,
|
||
hzIduModemReset INTEGER,
|
||
hzIduModemChannelizedRSL INTEGER,
|
||
hzIduModemChannelizedRSLUnsignedInt INTEGER,
|
||
hzIduModemModulationType INTEGER,
|
||
hzIduModemRxSpeed INTEGER,
|
||
hzIduModemTxSpeed INTEGER,
|
||
hzIduModemSNR INTEGER,
|
||
hzIduModemEbToNoiseRatio INTEGER,
|
||
hzIduModemEqualizerStress INTEGER,
|
||
hzIduModemSNRThresholdParameters DisplayString,
|
||
hzIduModemChannelizedRslBelowThresholdParameters DisplayString
|
||
}
|
||
|
||
hzIduModemIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each interface. "
|
||
::= { hzIduModemEntry 1 }
|
||
|
||
hzIduModemOperStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { up ( 1 ), down( 2 ), testing (3) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current operational state of the interface. Testing indicates that no operational packets can be passed."
|
||
::= { hzIduModemEntry 2 }
|
||
|
||
hzIduModemReset OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0 .. 1 )
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Writing 1 to this object causes the modem card to be reset.
|
||
All other values are not recognized. This variable always
|
||
reads back as 0. mdmOperStatus should be polled by the
|
||
user after this object is written to, to verify that the
|
||
modem card has been reset. Not applicable in this release"
|
||
::= { hzIduModemEntry 3 }
|
||
|
||
hzIduModemChannelizedRSL OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "An estimate of the modem's channelized RSL. Divide the value by 10 to get the actual RSL value. Once this number is divided by 10 the units are dBm. For example 352 is actually -35.2dBm"
|
||
::= { hzIduModemEntry 4 }
|
||
|
||
hzIduModemChannelizedRSLUnsignedInt OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The absolute value of the estimate of the modem's channelized RSL. Divide the value by 10 to get the actual RSL value. Once this number is divided by 10 the units are dBm. For example -352 is actually -35.2dBm"
|
||
::= { hzIduModemEntry 5 }
|
||
|
||
hzIduModemModulationType OBJECT-TYPE
|
||
SYNTAX INTEGER { qpsk ( 1 ) , qam ( 2 ) , qam16 ( 3 ) , qam32 ( 4 ) , qam64 ( 5 ) , qam128 ( 6 ) , qam256 ( 7 ) , x8psk ( 8 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The modulation type of the modem, distinguished according
|
||
to the physical/link protocol."
|
||
::= { hzIduModemEntry 6 }
|
||
|
||
hzIduModemRxSpeed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "An estimate of the modem's current Rx bandwidth in bits per
|
||
second. Divide the value by 10000 to get the actual data rate in Mbps"
|
||
::= { hzIduModemEntry 7 }
|
||
|
||
hzIduModemTxSpeed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "An estimate of the modem's current Tx bandwidth in bits per
|
||
second. Divide the value by 10000 to get the actual data rate in Mbps"
|
||
::= { hzIduModemEntry 8 }
|
||
|
||
hzIduModemSNR OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "SNR value in dB. Divide the value by 10 to get the actual SNR."
|
||
::= { hzIduModemEntry 9 }
|
||
|
||
hzIduModemEbToNoiseRatio OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The ratio of the modem Estimated Energy per information bit to Noise power spectral density.
|
||
Divide the value by 10 to get the actual EbToNoiseRatio"
|
||
::= { hzIduModemEntry 10 }
|
||
|
||
hzIduModemEqualizerStress OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the average magnitude of all the equalizer taps to provide a measure of how hard the equalizer is working."
|
||
::= { hzIduModemEntry 11 }
|
||
|
||
hzIduModemSNRThresholdParameters OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "A read-write string "
|
||
::= { hzIduModemEntry 12 }
|
||
|
||
|
||
hzIduModemChannelizedRslBelowThresholdParameters OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "A read-write string: The threshold in dBm and the number of seconds threshold are programmed by the user. An example of the format of the string is as follows: '-75 10'. The first parameter power level in dBm, the second is the time in seconds that the threshold must be exceeded. In this example the threshold -75 dBm and the time is set to 10 seconds. The single quote marks i.e. ' ' are not used in the command."
|
||
::= { hzIduModemEntry 13 }
|
||
|
||
-- ----------------------------
|
||
-- hzIduWirelessInterfaceModems
|
||
-- ----------------------------
|
||
|
||
hzIduModemStatsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduModemStatsEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of Wireless Interface Modem Statistics"
|
||
::= { hzIduWirelessInterfaceModems 3 }
|
||
|
||
hzIduModemStatsEntry OBJECT-TYPE
|
||
SYNTAX HzIduModemStatsEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Statistics for a Wireless Interface Modem"
|
||
INDEX { hzIduModemStatsIndex }
|
||
::= { hzIduModemStatsTable 1 }
|
||
|
||
HzIduModemStatsEntry ::= SEQUENCE {
|
||
hzIduModemStatsIndex INTEGER,
|
||
hzIduModemTxBlocks Counter,
|
||
hzIduModemRxBlocksOKs Counter,
|
||
hzIduModemRxBlocksErrors Counter
|
||
}
|
||
|
||
hzIduModemStatsIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each interface. "
|
||
::= { hzIduModemStatsEntry 1 }
|
||
|
||
hzIduModemTxBlocks OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of Modem blocks transmitted."
|
||
::= { hzIduModemStatsEntry 2 }
|
||
|
||
hzIduModemRxBlocksOKs OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of Modem blocks received."
|
||
::= { hzIduModemStatsEntry 3 }
|
||
|
||
hzIduModemRxBlocksErrors OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current count of Modem blocks received in error."
|
||
::= { hzIduModemStatsEntry 4 }
|
||
|
||
--
|
||
-- RADIO INFORMATION
|
||
--
|
||
|
||
hzIduRadioTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduRadioEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of Wireless Interface Radios"
|
||
::= { hzIduWirelessInterfaceRadios 1 }
|
||
|
||
hzIduRadioEntry OBJECT-TYPE
|
||
SYNTAX HzIduRadioEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A Wireless Interface Radio"
|
||
INDEX { hzIduRadioIndex }
|
||
::= { hzIduRadioTable 1 }
|
||
|
||
HzIduRadioEntry ::= SEQUENCE {
|
||
hzIduRadioIndex INTEGER,
|
||
hzIduRadioDescription DisplayString,
|
||
hzIduRadioOperStatus INTEGER,
|
||
hzIduRadioLastChanged TimeTicks,
|
||
hzIduRadioReceiveSignalLevel INTEGER,
|
||
hzIduRadioReceiveSignalLevelUnsigned INTEGER,
|
||
hzIduRadioTxGain INTEGER,
|
||
hzIduRadioRxGain INTEGER,
|
||
hzIduRadioReset INTEGER,
|
||
hzIduRadioTransmitPowerdBm INTEGER,
|
||
hzIduRadioPowerOption INTEGER,
|
||
hzIduRadioTxState INTEGER,
|
||
hzIduRadioTemperature INTEGER,
|
||
hzIduRadioRxCableLoss DisplayString,
|
||
hzIduRadioTxCableLoss DisplayString,
|
||
hzIduRadioTxCableLossChange DisplayString
|
||
}
|
||
|
||
hzIduRadioIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each interface. "
|
||
::= { hzIduRadioEntry 1 }
|
||
|
||
hzIduRadioDescription OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual string containing information about the radio. Includes the
|
||
manufacturer, product name, software version, serial number, and hardware
|
||
version of the radio."
|
||
::= { hzIduRadioEntry 2 }
|
||
|
||
hzIduRadioOperStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { up ( 1 ) , down ( 2 ) , testing ( 3 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current operational state of the interface. Testing
|
||
indicates that no operational packets can be passed. Testing
|
||
also indicates that a firmware upgrade may be in progress"
|
||
::= { hzIduRadioEntry 3 }
|
||
|
||
hzIduRadioLastChanged OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The value of sysUpTime at the time the radio entered its current
|
||
operational state. If the current state was entered prior to the
|
||
last re-initialization of the local network management subsystem,
|
||
then this object contains a zero value."
|
||
::= { hzIduRadioEntry 4 }
|
||
|
||
hzIduRadioReceiveSignalLevel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The Received Signal Level indicates the power of the receive level
|
||
in dBm. The number is divided by 10 to get the actual dBm. For example,
|
||
-432 is actually -43.2dBm."
|
||
::= { hzIduRadioEntry 5 }
|
||
|
||
hzIduRadioReceiveSignalLevelUnsigned OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The Received Signal Level indicates the power of the receive level in dBm.
|
||
The number is divided by -10. e.g. 432 is actually -43.2dBm. Object provided
|
||
to accomodate plotting of negative RSL values which is not supported
|
||
in some EMS (i.e.: CastleRock). Please use 'hzIduRadioReceiveSignalLevel'
|
||
object if your EMS supports plotting of negative integers."
|
||
::= { hzIduRadioEntry 6 }
|
||
|
||
hzIduRadioTxGain OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The gain of the radio in the transmit chain. Indicates the gain in dB."
|
||
::= { hzIduRadioEntry 7 }
|
||
|
||
hzIduRadioRxGain OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The gain of the radio in the receive chain. Indicates the gain in dB."
|
||
::= { hzIduRadioEntry 8 }
|
||
|
||
hzIduRadioReset OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Writing 1 to this object causes the radio to be reset. All other values
|
||
are not recognized. This variable always reads back as 0. radioOperStatus
|
||
should be polled by the user after this object is written to, to verify
|
||
that the radio card has been reset."
|
||
::= { hzIduRadioEntry 9 }
|
||
|
||
hzIduRadioTransmitPowerdBm OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "This defines the transmit level of the radio. If ATPC or AAM is enabled, you can't change the transmit power.
|
||
|
||
The power you see is divided by 10. e.g. A display of 133 is actually 13.3 dBm.
|
||
|
||
If the radio is operational and not muted, it is the current transmitting power.
|
||
|
||
If the radio is operational and muted, it is the programmed transmitting power, and will transmit at this level when the radio is un-muted.
|
||
|
||
If the radio is not operational it is the programmed transmitting power, and will transmit at this level when the radio is operational and not muted.
|
||
|
||
If the radio does not have transmit calibration tables programmed into its EEPROM, this transmit power level cannot be used as it is not possible to accurately calculate the actual transmit level. In this case this object will return -99."
|
||
DEFVAL { 0 }
|
||
::= { hzIduRadioEntry 10 }
|
||
|
||
|
||
hzIduRadioPowerOption OBJECT-TYPE
|
||
SYNTAX INTEGER { normal ( 1 ) , highPower ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This indicates the power option of the radio: normal or high power."
|
||
DEFVAL { 0 }
|
||
::= { hzIduRadioEntry 11 }
|
||
|
||
|
||
hzIduRadioTxState OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This indicates the power option of the radio: normal or high power."
|
||
DEFVAL { 0 }
|
||
::= { hzIduRadioEntry 12 }
|
||
|
||
hzIduRadioTemperature OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The Radio temperature in degree Celsius. The actual temperature is determined by dividing the number by 10. e.g. 202 is actually 20.2 degrees Celsius."
|
||
::= { hzIduRadioEntry 13 }
|
||
|
||
hzIduRadioRxCableLoss OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The Rx Cable Loss in dB."
|
||
::= { hzIduRadioEntry 14 }
|
||
|
||
hzIduRadioTxCableLoss OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The Tx Cable Loss in dB."
|
||
::= { hzIduRadioEntry 15 }
|
||
|
||
hzIduRadioTxCableLossChange OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The Tx Cable Loss Change is the difference between the configured TxPower and the measured TxPower measured in dB."
|
||
::= { hzIduRadioEntry 16 }
|
||
|
||
-- --------------------------------------
|
||
-- hzIduWirelessInterfaceRadioFrequencies
|
||
-- --------------------------------------
|
||
|
||
hzIduWirelessInterfaceRadio1Frequencies OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterfaceRadioFrequencies 1 }
|
||
|
||
|
||
hzIduWirelessInterfaceRadio2Frequencies OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterfaceRadioFrequencies 2 }
|
||
|
||
-- --------------------------------------
|
||
-- hzIduWirelessInterfaceRadio1Frequencies
|
||
-- --------------------------------------
|
||
|
||
hzIduRadio1Band OBJECT-TYPE
|
||
-- ------------Don't forget to update Radio2 Band list! ------------------
|
||
SYNTAX INTEGER { freqNone (1), fcc11-1-40 (2), fcc11-1-30 (3), fcc18-2-40 (4), fcc18-2-50(5), fcc23-3-50(6) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The radio frequency standard used for Radio 1. Frequency bands are divided into sub bands.
|
||
|
||
i.e. FCC 23 Ghz Band is comprised of fcc23a, fcc23b, fcc23c and
|
||
fcc23d which make up the entire FCC23 band"
|
||
DEFVAL { freqNone }
|
||
::= { hzIduWirelessInterfaceRadio1Frequencies 1 }
|
||
|
||
|
||
hzIduRadio1FreqGroupSelected OBJECT-TYPE
|
||
SYNTAX INTEGER { txLow ( 1 ) , txHigh ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The frequency group selected for Radio 1.
|
||
|
||
The frequency subbands are divided into frequency groups txHigh and txLow. An horizon system must have one node configured to txLow and the other node configure to txHigh"
|
||
::= { hzIduWirelessInterfaceRadio1Frequencies 2 }
|
||
|
||
hzIduRadio1TxHighFreqTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduRadio1TxHighFreqEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of txHigh frequency settings for Radio 1"
|
||
::= { hzIduWirelessInterfaceRadio1Frequencies 3 }
|
||
|
||
hzIduRadio1TxHighFreqEntry OBJECT-TYPE
|
||
SYNTAX HzIduRadio1TxHighFreqEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A txHighFrequency entry containing all the frequency values"
|
||
INDEX { hzIduRadio1TxHighFreqIndex }
|
||
::= { hzIduRadio1TxHighFreqTable 1 }
|
||
|
||
HzIduRadio1TxHighFreqEntry ::= SEQUENCE {
|
||
hzIduRadio1TxHighFreqIndex INTEGER,
|
||
hzIduRadio1TxHighFreqChannelIndex DisplayString,
|
||
hzIduRadio1TxHighFreqTransmitRfFrequency INTEGER,
|
||
hzIduRadio1TxHighFreqReceiveRfFrequency INTEGER,
|
||
hzIduRadio1TxHighFreqProgrammed INTEGER
|
||
}
|
||
|
||
|
||
hzIduRadio1TxHighFreqIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each frequency channel. "
|
||
::= { hzIduRadio1TxHighFreqEntry 1 }
|
||
|
||
|
||
hzIduRadio1TxHighFreqChannelIndex OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The channel index for the frequency."
|
||
::= { hzIduRadio1TxHighFreqEntry 2 }
|
||
|
||
hzIduRadio1TxHighFreqTransmitRfFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The RF TX frequency in KHz."
|
||
::= { hzIduRadio1TxHighFreqEntry 3 }
|
||
|
||
hzIduRadio1TxHighFreqReceiveRfFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The RF RX frequency in KHz."
|
||
::= { hzIduRadio1TxHighFreqEntry 4 }
|
||
|
||
hzIduRadio1TxHighFreqProgrammed OBJECT-TYPE
|
||
SYNTAX INTEGER { active ( 1 ) , notActive ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies the operating frequency channel for the modem.
|
||
|
||
***Only 1 index may be selected in a 1 modem system."
|
||
DEFVAL { notActive }
|
||
::= { hzIduRadio1TxHighFreqEntry 5 }
|
||
|
||
hzIduRadio1TxLowFreqTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduRadio1TxLowFreqEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of txLow frequency settings for Radio 1"
|
||
::= { hzIduWirelessInterfaceRadio1Frequencies 4 }
|
||
|
||
hzIduRadio1TxLowFreqEntry OBJECT-TYPE
|
||
SYNTAX HzIduRadio1TxLowFreqEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A hzIduTxLowFrequeny entry containing the frequency values for a specific index"
|
||
INDEX { hzIduRadio1TxLowFreqIndex }
|
||
::= { hzIduRadio1TxLowFreqTable 1 }
|
||
|
||
HzIduRadio1TxLowFreqEntry ::= SEQUENCE {
|
||
hzIduRadio1TxLowFreqIndex INTEGER,
|
||
hzIduRadio1TxLowFreqChannelIndex DisplayString,
|
||
hzIduRadio1TxLowFreqTransmitRfFrequency INTEGER,
|
||
hzIduRadio1TxLowFreqReceiveRfFrequency INTEGER,
|
||
hzIduRadio1TxLowFreqProgrammed INTEGER
|
||
}
|
||
|
||
|
||
hzIduRadio1TxLowFreqIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each frequency channel. "
|
||
::= { hzIduRadio1TxLowFreqEntry 1 }
|
||
|
||
|
||
hzIduRadio1TxLowFreqChannelIndex OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The channel index for the frequency. "
|
||
::= { hzIduRadio1TxLowFreqEntry 2 }
|
||
|
||
hzIduRadio1TxLowFreqTransmitRfFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The RF TX frequency in KHz."
|
||
::= { hzIduRadio1TxLowFreqEntry 3 }
|
||
|
||
hzIduRadio1TxLowFreqReceiveRfFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The RF RX frequency in KHz."
|
||
::= { hzIduRadio1TxLowFreqEntry 4 }
|
||
|
||
hzIduRadio1TxLowFreqProgrammed OBJECT-TYPE
|
||
SYNTAX INTEGER { active ( 1 ) , notActive ( 2 ) }
|
||
ACCESS read-write
|
||
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies the operating frequency channel for the modem.
|
||
|
||
***Only 1 index may be selected in a 1 modem system. "
|
||
DEFVAL { notActive }
|
||
::= { hzIduRadio1TxLowFreqEntry 5 }
|
||
|
||
|
||
hzIduRadio1ProgrammedFrequency OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterfaceRadio1Frequencies 5 }
|
||
|
||
hzIduRadio1ProgrammedFrequencyChannel OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The channel that has been programmed for Radio 1."
|
||
::= { hzIduRadio1ProgrammedFrequency 1 }
|
||
|
||
|
||
hzIduRadio1ProgrammedFrequencyTxRf OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The programmed RF TX frequency in KHz."
|
||
::= { hzIduRadio1ProgrammedFrequency 2 }
|
||
|
||
|
||
hzIduRadio1ProgrammedFrequencyRxRf OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The RF RX frequency in KHz."
|
||
::= { hzIduRadio1ProgrammedFrequency 3 }
|
||
|
||
|
||
-- --------------------------------------
|
||
-- hzIduWirelessInterfaceRadio2Frequencies
|
||
-- --------------------------------------
|
||
|
||
hzIduRadio2Band OBJECT-TYPE
|
||
-- ------------Don't forget to update Radio1 Band list! ------------------
|
||
SYNTAX INTEGER { freqNone (1), fcc11-1-40 (2), fcc11-1-30 (3), fcc18-2-40 (4), fcc18-2-50(5), fcc23-3-50(6) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The radio frequency standard used by Radio 2 (if present). Frequency bands are divided into sub bands.
|
||
|
||
i.e. FCC 23 Ghz Band is comprised of fcc23a, fcc23b, fcc23c and fcc23d which make up the entire FCC23 band"
|
||
DEFVAL { freqNone }
|
||
::= { hzIduWirelessInterfaceRadio2Frequencies 1 }
|
||
|
||
|
||
hzIduRadio2FreqGroupSelected OBJECT-TYPE
|
||
SYNTAX INTEGER { txLow ( 1 ) , txHigh ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The frequency group selected for Radio 2.
|
||
|
||
The frequency subbands are divided into frequency groups txHigh and txLow. An horizon system must have one node configured to txLow and the other node configure to txHigh"
|
||
::= { hzIduWirelessInterfaceRadio2Frequencies 2 }
|
||
|
||
hzIduRadio2TxHighFreqTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduRadio2TxHighFreqEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of txHigh frequency settings for Radio 2"
|
||
::= { hzIduWirelessInterfaceRadio2Frequencies 3 }
|
||
|
||
hzIduRadio2TxHighFreqEntry OBJECT-TYPE
|
||
SYNTAX HzIduRadio2TxHighFreqEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A txHighFrequency entry containing all the frequency values"
|
||
INDEX { hzIduRadio2TxHighFreqIndex }
|
||
::= { hzIduRadio2TxHighFreqTable 1 }
|
||
|
||
HzIduRadio2TxHighFreqEntry ::= SEQUENCE {
|
||
hzIduRadio2TxHighFreqIndex INTEGER,
|
||
hzIduRadio2TxHighFreqChannelIndex DisplayString,
|
||
hzIduRadio2TxHighFreqTransmitRfFrequency INTEGER,
|
||
hzIduRadio2TxHighFreqReceiveRfFrequency INTEGER,
|
||
hzIduRadio2TxHighFreqProgrammed INTEGER
|
||
}
|
||
|
||
|
||
hzIduRadio2TxHighFreqIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each frequency channel. "
|
||
::= { hzIduRadio2TxHighFreqEntry 1 }
|
||
|
||
|
||
hzIduRadio2TxHighFreqChannelIndex OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The channel index for the frequency."
|
||
::= { hzIduRadio2TxHighFreqEntry 2 }
|
||
|
||
hzIduRadio2TxHighFreqTransmitRfFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The RF TX frequency in KHz."
|
||
::= { hzIduRadio2TxHighFreqEntry 3 }
|
||
|
||
hzIduRadio2TxHighFreqReceiveRfFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The RF RX frequency in KHz."
|
||
::= { hzIduRadio2TxHighFreqEntry 4 }
|
||
|
||
hzIduRadio2TxHighFreqProgrammed OBJECT-TYPE
|
||
SYNTAX INTEGER { active ( 1 ) , notActive ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies the operating frequency channel for the modem.
|
||
|
||
***Only 1 index may be selected in a 1 modem system."
|
||
DEFVAL { notActive }
|
||
::= { hzIduRadio2TxHighFreqEntry 5 }
|
||
|
||
hzIduRadio2TxLowFreqTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduRadio2TxLowFreqEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of txLow frequency settings for Radio 2"
|
||
::= { hzIduWirelessInterfaceRadio2Frequencies 4 }
|
||
|
||
hzIduRadio2TxLowFreqEntry OBJECT-TYPE
|
||
SYNTAX HzIduRadio2TxLowFreqEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A hzIduTxLowFrequeny entry containing the frequency values for a specific index"
|
||
INDEX { hzIduRadio2TxLowFreqIndex }
|
||
::= { hzIduRadio2TxLowFreqTable 1 }
|
||
|
||
HzIduRadio2TxLowFreqEntry ::= SEQUENCE {
|
||
hzIduRadio2TxLowFreqIndex INTEGER,
|
||
hzIduRadio2TxLowFreqChannelIndex DisplayString,
|
||
hzIduRadio2TxLowFreqTransmitRfFrequency INTEGER,
|
||
hzIduRadio2TxLowFreqReceiveRfFrequency INTEGER,
|
||
hzIduRadio2TxLowFreqProgrammed INTEGER
|
||
}
|
||
|
||
|
||
hzIduRadio2TxLowFreqIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each frequency channel. "
|
||
::= { hzIduRadio2TxLowFreqEntry 1 }
|
||
|
||
|
||
hzIduRadio2TxLowFreqChannelIndex OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The channel index for the frequency. "
|
||
::= { hzIduRadio2TxLowFreqEntry 2 }
|
||
|
||
hzIduRadio2TxLowFreqTransmitRfFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The RF TX frequency in KHz."
|
||
::= { hzIduRadio2TxLowFreqEntry 3 }
|
||
|
||
hzIduRadio2TxLowFreqReceiveRfFrequency OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The RF RX frequency in KHz."
|
||
::= { hzIduRadio2TxLowFreqEntry 4 }
|
||
|
||
hzIduRadio2TxLowFreqProgrammed OBJECT-TYPE
|
||
SYNTAX INTEGER { active ( 1 ) , notActive ( 2 ) }
|
||
ACCESS read-write
|
||
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies the operating frequency channel for the modem.
|
||
|
||
***Only 1 index may be selected in a 1 modem system. "
|
||
DEFVAL { notActive }
|
||
::= { hzIduRadio2TxLowFreqEntry 5 }
|
||
|
||
|
||
hzIduRadio2ProgrammedFrequency OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterfaceRadio2Frequencies 5 }
|
||
|
||
hzIduRadio2ProgrammedFrequencyChannel OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The channel that has been programmed for Radio 2."
|
||
::= { hzIduRadio2ProgrammedFrequency 1 }
|
||
|
||
|
||
hzIduRadio2ProgrammedFrequencyTxRf OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The programmed RF TX frequency in KHz."
|
||
::= { hzIduRadio2ProgrammedFrequency 2 }
|
||
|
||
|
||
hzIduRadio2ProgrammedFrequencyRxRf OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The RF RX frequency in KHz."
|
||
::= { hzIduRadio2ProgrammedFrequency 3 }
|
||
|
||
-- --------------------------------
|
||
-- hzIduWirelessInterfaceRedundancy
|
||
-- --------------------------------
|
||
|
||
hzIduWirelessInterfaceRedundancyActiveWirelessPort OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 (1), wireless-port-2 (2) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This attribute indicates the active wireless port and is only applicable when the system capacity has been configured to singleCarrier-redundancy."
|
||
::= { hzIduWirelessInterfaceRedundancy 1 }
|
||
|
||
hzIduWirelessInterfaceRedundancyPrimaryWirelessPort OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 (1), wireless-port-2 (2) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "This attribute indicates the primary wireless port and is only applicable when the system capacity has been configured to singleCarrier-redundancy. The primary wireless port indicates which wireless port is connected to the 'primary' port on the RDRM coupler."
|
||
::= { hzIduWirelessInterfaceRedundancy 2 }
|
||
|
||
hzIduWirelessInterfaceRedundancySwitchingAlgorithm OBJECT-TYPE
|
||
SYNTAX INTEGER { manual ( 1 ), algorithm-based ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "This attribute selects the rule that will determine when a redundant path switch will take place. There are two options: manual and algorithm-based. The 'Manual' option turns off the automatic path switching feature. Only an operator can switch the active path."
|
||
::= { hzIduWirelessInterfaceRedundancy 3 }
|
||
|
||
hzIduWirelessInterfaceRedundancySwitchCause OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This string indicates the reason that a redundancy switch has occurred. If the active port is the primary port then this string is empty."
|
||
::= { hzIduWirelessInterfaceRedundancy 4 }
|
||
|
||
hzIduWirelessInterfaceRedundancySwitchRadio OBJECT-TYPE
|
||
SYNTAX INTEGER { switch ( 1 ) }
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This object switches the active path when switch (1) is written to this variable."
|
||
::= { hzIduWirelessInterfaceRedundancy 5 }
|
||
|
||
hzIduWirelessInterfaceRedundancyRemoveFaultyWirelessPort OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 (1), wireless-port-2 (2) }
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This object removes the specified port from the faulty port list."
|
||
::= { hzIduWirelessInterfaceRedundancy 6 }
|
||
|
||
hzIduWirelessInterfaceRedundancyDiagnostics OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterfaceRedundancy 7 }
|
||
|
||
-- ---------------------------------------------
|
||
-- hzIduWirelessInterfaceRedundancyDiagnostics
|
||
-- ---------------------------------------------
|
||
|
||
hzIduWirelessInterfaceRedundancyDiagnose OBJECT-TYPE
|
||
SYNTAX INTEGER { diagnose ( 1 ) }
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This write-only object will diagnose problems with switching paths. Write diagnose (1) to this object and check results in hzIduWirelessInterfaceRedundancyDiagnosticResult object"
|
||
::= { hzIduWirelessInterfaceRedundancyDiagnostics 1 }
|
||
|
||
hzIduWirelessInterfaceRedundancyDiagnosticResult OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The result from Redundancy Diagnostic is read from this object. Note that the diagnostic result presented in this object is private to SNMP initiated diagnostics. If a diagnostic is initiated from the CLI or WEB, this result will remain unchanged."
|
||
::= { hzIduWirelessInterfaceRedundancyDiagnostics 2 }
|
||
|
||
-- ----------------------------
|
||
-- hzIduWirelessInterfaceAntenna
|
||
-- ----------------------------
|
||
|
||
hzIduAntennaDiameter OBJECT-TYPE
|
||
SYNTAX INTEGER { antenna12 ( 1 ), antenna24 ( 2 ), antenna36 ( 3 ), antenna48 ( 4 ), antenna72 ( 5 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This defines the diameter of the antenna represented in inches."
|
||
::= { hzIduWirelessInterfaceAntenna 1 }
|
||
|
||
--
|
||
-- hzIduCalendar
|
||
--
|
||
|
||
hzIduDate OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A string in the format as follows:
|
||
XX/YY/ZZ
|
||
Where XX = day of month (range 01 to 31)
|
||
YY = month of year(range 01 to 12)
|
||
ZZ = year (range 01 - 99)"
|
||
::= { hzIduCalendar 1 }
|
||
|
||
hzIduTime OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A string in the format as follows:
|
||
aa:bb:cc.ddd
|
||
Where aa = hour of day ( range 00 to 23 )
|
||
bb = minute of hour ( range 00 to 59 )
|
||
cc = second of minute( range 00 to 59 )
|
||
ddd = thousandths of second (range 000 to 999)"
|
||
::= { hzIduCalendar 2 }
|
||
|
||
--
|
||
-- ALARM FOLDER
|
||
--
|
||
|
||
hzIduClearAlarmCounters OBJECT-TYPE
|
||
SYNTAX INTEGER { nicCounters ( 1 ) , modemCounters ( 2 ) , radioCounters ( 3 ) , allCounters ( 4 ), otherCounters (5) }
|
||
ACCESS write-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Clears the alarm counters for the specified group"
|
||
::= { hzIduAlarms 1 }
|
||
|
||
hzIduSystemAlarms OBJECT IDENTIFIER
|
||
::= { hzIduAlarms 2 }
|
||
|
||
hzIduNetworkInterfaceAlarms OBJECT IDENTIFIER
|
||
::= { hzIduAlarms 3 }
|
||
|
||
hzIduEnetPort1Alarms OBJECT IDENTIFIER
|
||
::= { hzIduNetworkInterfaceAlarms 1 }
|
||
|
||
hzIduEnetPort2Alarms OBJECT IDENTIFIER
|
||
::= { hzIduNetworkInterfaceAlarms 2 }
|
||
|
||
hzIduWirelessInterfaceAlarms OBJECT IDENTIFIER
|
||
::= { hzIduAlarms 4 }
|
||
|
||
hzIduModemAlarms OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterfaceAlarms 1 }
|
||
|
||
hzIduRadioAlarms OBJECT IDENTIFIER
|
||
::= { hzIduWirelessInterfaceAlarms 2 }
|
||
|
||
|
||
|
||
--
|
||
-- System Alarms
|
||
--
|
||
|
||
hzIduExplicitAuthenticationFailure OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Authentication of the peer horizon node has failed. The severity is critical, the probable cause is an incorrect authentication configuration on horizon faulty cable between the modem and radio, and recommended course of action is to check both ends of the link."
|
||
::= { hzIduSystemAlarms 1 }
|
||
|
||
hzIduExplicitAuthenticationFailureCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the number of times explicit authentication has failed."
|
||
::= { hzIduSystemAlarms 2 }
|
||
|
||
hzIduAamConfigMismatch OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "In the near end Automatic Adaptive Modulation(AAM) feature set to on and in peer it is set to off"
|
||
::= { hzIduSystemAlarms 3 }
|
||
|
||
hzIduAamConfigMismatchCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds AAMConfigMismatch alarm has been active."
|
||
::= { hzIduSystemAlarms 4 }
|
||
|
||
hzIduAamActive OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates aam is active and system running on lowest modulation"
|
||
::= { hzIduSystemAlarms 5 }
|
||
|
||
hzIduAamActiveCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds AAMActive alarm has been active."
|
||
::= { hzIduSystemAlarms 6 }
|
||
|
||
|
||
hzIduSntpServerUnavailableAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "All of the SNTP servers are not available. "
|
||
::= { hzIduSystemAlarms 7 }
|
||
|
||
|
||
hzIduSntpServerUnavailableAlarmCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates how long in seconds all of the SNTP servers are not available."
|
||
::= { hzIduSystemAlarms 8 }
|
||
|
||
hzIduFrequencyFileInvalid OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Executing frequency file is invalid."
|
||
::= { hzIduSystemAlarms 9 }
|
||
|
||
hzIduFrequencyFileInvalidCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the time (in secs) since this alarm exist."
|
||
::= { hzIduSystemAlarms 10 }
|
||
|
||
|
||
hzIduFan1Failure OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates that Fan 1 has failed."
|
||
::= { hzIduSystemAlarms 11 }
|
||
|
||
hzIduFan1FailureCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the number of seconds that the fan has failed for."
|
||
::= { hzIduSystemAlarms 12 }
|
||
|
||
hzIduFan2Failure OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates that Fan 2 has failed."
|
||
::= { hzIduSystemAlarms 13 }
|
||
|
||
hzIduFan2FailureCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the number of seconds that the fan has failed for."
|
||
::= { hzIduSystemAlarms 14 }
|
||
|
||
hzIduFan3Failure OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates that Fan 3 has failed."
|
||
::= { hzIduSystemAlarms 15 }
|
||
|
||
hzIduFan3FailureCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the number of seconds that the fan has failed for."
|
||
::= { hzIduSystemAlarms 16 }
|
||
|
||
hzIduFan4Failure OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates that Fan 4 has failed."
|
||
::= { hzIduSystemAlarms 17 }
|
||
|
||
hzIduFan4FailureCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the number of seconds that the fan has failed for."
|
||
::= { hzIduSystemAlarms 18 }
|
||
|
||
hzIduPrimaryPortNotSet OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The primary port used for redundancy has not been set."
|
||
::= { hzIduSystemAlarms 19 }
|
||
|
||
hzIduPrimaryPortNotSetCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduSystemAlarms 20 }
|
||
|
||
hzIduSecondaryPortActive OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The active wireless port has switched to the secondary wireless port."
|
||
::= { hzIduSystemAlarms 21 }
|
||
|
||
hzIduSecondaryPortActiveCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduSystemAlarms 22 }
|
||
|
||
hzIduPrimaryPortFaulty OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The primary wireless port is faulty."
|
||
::= { hzIduSystemAlarms 23 }
|
||
|
||
hzIduPrimaryPortFaultyCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduSystemAlarms 24 }
|
||
|
||
hzIduSecondaryPortFaulty OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The secondary wireless port is faulty."
|
||
::= { hzIduSystemAlarms 25 }
|
||
|
||
hzIduSecondaryPortFaultyCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduSystemAlarms 26 }
|
||
|
||
--
|
||
-- NETWORK INTERFACE PORT1 ALARMS
|
||
--
|
||
|
||
hzIduEnetPort1DroppedEnetFramesThresholdExceeded OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The threshold for number of frames dropped has been exceeded. The threshold and the number of seconds that it must exceed this threshold are programmed by the user."
|
||
::= { hzIduEnetPort1Alarms 1 }
|
||
|
||
|
||
hzIduEnetPort1DroppedEnetFramesThresholdCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
|
||
::= { hzIduEnetPort1Alarms 2 }
|
||
|
||
hzIduEnetPort1BandwidthUtilizationThresholdExceeded OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The threshold for the percentage of available bandwidth has been exceeded. The threshold and the number of seconds that it must exceed this threshold are programmed by the user."
|
||
::= { hzIduEnetPort1Alarms 3 }
|
||
|
||
|
||
hzIduEnetPort1BandwidthUtilizationThresholdCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
|
||
::= { hzIduEnetPort1Alarms 4 }
|
||
|
||
hzIduEnetPort1RlsMismatch OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "RLS configurations on the pair of systems are mismatched."
|
||
::= { hzIduEnetPort1Alarms 5 }
|
||
|
||
hzIduEnetPort1RlsMismatchCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
|
||
::= { hzIduEnetPort1Alarms 6 }
|
||
|
||
|
||
hzIduRLSQueueBasedShutdownActivated OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "RLS Queue-Based shutdown is activated."
|
||
::= { hzIduEnetPort1Alarms 7 }
|
||
|
||
hzIduRLSQueueBasedShutdownActivatedCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
|
||
::= { hzIduEnetPort1Alarms 8 }
|
||
|
||
hzIduEnetPort1EthernetLinkDown OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates whether the Ethernet link is down or not. The severity is major, the probable cause is an incorrect configuration of the switch or router connected to horizon. The recommended course of action is to check the connection."
|
||
::= { hzIduEnetPort1Alarms 9 }
|
||
|
||
hzIduEnetPort1EthernetLinkDownActivatedCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
|
||
::= { hzIduEnetPort1Alarms 10 }
|
||
|
||
--
|
||
-- NETWORK INTERFACE Port2 ALARMS
|
||
--
|
||
|
||
hzIduEnetPort2EthernetLinkDown OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates whether the Ethernet link is down or not. The severity is major, the probable cause is an incorrect configuration of the switch or router connected to horizon. The recommended course of action is to check the connection."
|
||
::= { hzIduEnetPort2Alarms 1 }
|
||
|
||
hzIduEnetPort2EthernetLinkDownActivatedCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
|
||
::= { hzIduEnetPort2Alarms 2 }
|
||
|
||
|
||
--
|
||
-- MODEM ALARMS
|
||
--
|
||
|
||
hzIduModemAlarmsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduModemAlarmsEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of Modem Alarms."
|
||
::= { hzIduModemAlarms 1 }
|
||
|
||
hzIduModemAlarmsEntry OBJECT-TYPE
|
||
SYNTAX HzIduModemAlarmsEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Modem Alarms"
|
||
INDEX { hzIduModemAlarmsIndex }
|
||
::= { hzIduModemAlarmsTable 1 }
|
||
|
||
HzIduModemAlarmsEntry ::= SEQUENCE {
|
||
hzIduModemAlarmsIndex INTEGER,
|
||
hzIduModemRxLossOfSignal INTEGER,
|
||
hzIduModemRxLossOfSignalCounts Counter,
|
||
hzIduModemTxLossOfSync INTEGER,
|
||
hzIduModemTxLossOfSyncCounts Counter,
|
||
hzIduModemSnrBelowThreshold INTEGER,
|
||
hzIduModemSnrBelowThresholdCounts Counter,
|
||
hzIduModemEqualizerStressExceedThreshold INTEGER,
|
||
hzIduModemEquilizerStressExceedThresholdCounts Counter,
|
||
hzIduModemHardwareFault INTEGER,
|
||
hzIduModemHardwareFaultCounts Counter,
|
||
hzIduModemProgrammingError INTEGER,
|
||
hzIduModemProgrammingErrorCounts Counter,
|
||
hzIduRLSShutdownActivated INTEGER,
|
||
hzIduRLSShutdownActivatedCounts Counter
|
||
|
||
}
|
||
|
||
hzIduModemAlarmsIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each interface. "
|
||
::= { hzIduModemAlarmsEntry 1 }
|
||
|
||
hzIduModemRxLossOfSignal OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Loss of signal lock from the demodulator. The severity is critical, the probable cause is lost synchronization with the far end, and recommended course of action is to check the operational state of both ends of the link."
|
||
::= { hzIduModemAlarmsEntry 2 }
|
||
|
||
hzIduModemRxLossOfSignalCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduModemAlarmsEntry 3 }
|
||
|
||
hzIduModemTxLossOfSync OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Loss of sync bytes at the input of the modulator. The severity is critical, the probable cause is physical interference in the air link, and recommended course of action is to check the line of site between the horizon nodes."
|
||
::= { hzIduModemAlarmsEntry 4 }
|
||
|
||
hzIduModemTxLossOfSyncCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduModemAlarmsEntry 5 }
|
||
|
||
hzIduModemSnrBelowThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The demodulator SNR performance worse than programmed levels. The severity is major, the probable cause is physical interference in the air link path or misalignment of the radios or severe weather conditions, and recommended course of action is to check the line of site between the horizon nodes."
|
||
::= { hzIduModemAlarmsEntry 6 }
|
||
|
||
hzIduModemSnrBelowThresholdCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduModemAlarmsEntry 7 }
|
||
|
||
hzIduModemEqualizerStressExceedThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Equalizer Stress measured within the demodulator exceeds the threshold value."
|
||
::= { hzIduModemAlarmsEntry 8 }
|
||
|
||
|
||
hzIduModemEquilizerStressExceedThresholdCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduModemAlarmsEntry 9 }
|
||
|
||
hzIduModemHardwareFault OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION ""
|
||
::= { hzIduModemAlarmsEntry 10 }
|
||
|
||
hzIduModemHardwareFaultCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduModemAlarmsEntry 11 }
|
||
|
||
hzIduModemProgrammingError OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Encountered some problem while programming the modem."
|
||
::= { hzIduModemAlarmsEntry 12 }
|
||
|
||
hzIduModemProgrammingErrorCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduModemAlarmsEntry 13 }
|
||
|
||
hzIduRLSShutdownActivated OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "RLS shutdown is activated."
|
||
::= { hzIduModemAlarmsEntry 14 }
|
||
|
||
hzIduRLSShutdownActivatedCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
|
||
::= { hzIduModemAlarmsEntry 15 }
|
||
|
||
|
||
--
|
||
-- RADIO ALARMS
|
||
--
|
||
|
||
hzIduRadioAlarmsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduRadioAlarmsEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of Radio Alarms."
|
||
::= { hzIduRadioAlarms 1 }
|
||
|
||
hzIduRadioAlarmsEntry OBJECT-TYPE
|
||
SYNTAX HzIduRadioAlarmsEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Radio Alarms"
|
||
INDEX { hzIduRadioAlarmsIndex }
|
||
::= { hzIduRadioAlarmsTable 1 }
|
||
|
||
HzIduRadioAlarmsEntry ::= SEQUENCE {
|
||
hzIduRadioAlarmsIndex INTEGER,
|
||
hzIduRadioPLDROLostLock INTEGER,
|
||
hzIduRadioPLDROLostLockCounts Counter,
|
||
hzIduRadioLostCommunication INTEGER,
|
||
hzIduRadioLostCommunicationCounts Counter,
|
||
hzIduRadioMismatch INTEGER,
|
||
hzIduRadioMismatchCounts Counter,
|
||
hzIduRadioPowerAmp INTEGER,
|
||
hzIduRadioPowerAmpCounts Counter,
|
||
hzIduRadioExcessiveTxCableLoss INTEGER,
|
||
hzIduRadioExcessiveTxCableLossCounts Counter,
|
||
hzIduRadioRslBelowThreshold INTEGER,
|
||
hzIduRadioRslBelowThresholdCounts Counter,
|
||
hzIduRadioHighPowerOptionM1 INTEGER,
|
||
hzIduRadioHighPowerOptionM1Counts Counter,
|
||
hzIduRadioHighPowerOptionM2 INTEGER,
|
||
hzIduRadioHighPowerOptionM2Counts Counter,
|
||
hzIduRadioHighPowerTxDetector INTEGER,
|
||
hzIduRadioHighPowerTxDetectorCounts Counter,
|
||
hzIduRadioAtpcConfigMismatch INTEGER,
|
||
hzIduRadioAtpcConfigMismatchCounts Counter,
|
||
hzIduRadioRedundancySerialNumMismatch INTEGER,
|
||
hzIduRadioRedundancySerialNumMismatchCounts Counter,
|
||
hzIduRadioExcessiveTxCableLossChange INTEGER,
|
||
hzIduRadioExcessiveTxCableLossChangeCounts Counter,
|
||
hzIduRadioExcessiveRxCableLoss INTEGER,
|
||
hzIduRadioExcessiveRxCableLossCounts Counter,
|
||
hzIduRadioAtpcTxAtMaxPower INTEGER,
|
||
hzIduRadioAtpcTxAtMaxPowerCounts Counter
|
||
}
|
||
|
||
hzIduRadioAlarmsIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each radio interface. "
|
||
::= { hzIduRadioAlarmsEntry 1 }
|
||
|
||
hzIduRadioPLDROLostLock OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The PLDRO/LO has lost lock on the radio. The severity is critical, the probable cause a faulty radio unit and recommended course of action is to replace the radio unit."
|
||
::= { hzIduRadioAlarmsEntry 2 }
|
||
|
||
hzIduRadioPLDROLostLockCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduRadioAlarmsEntry 3 }
|
||
|
||
|
||
hzIduRadioLostCommunication OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "RS232 communication lost between IDU and the radio. The severity is critical, the probable cause is a faulty cable between the modem and radio, and recommended course of action is to check the connection."
|
||
::= { hzIduRadioAlarmsEntry 4 }
|
||
|
||
hzIduRadioLostCommunicationCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduRadioAlarmsEntry 5 }
|
||
|
||
hzIduRadioMismatch OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The radio connected to the IDU modem does not match the frequency programmed into the modem unit. The severity is major, the probable cause is an incorrectly programmed modem or an incorrect radio type connected to the modem, and recommended course of action is to check the modem frequency settings and radio hardware version number or serial number."
|
||
::= { hzIduRadioAlarmsEntry 6 }
|
||
|
||
hzIduRadioMismatchCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduRadioAlarmsEntry 7 }
|
||
|
||
|
||
hzIduRadioPowerAmp OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The power amplifier on the radio is not operating within normal operating specifications. The severity is critical, the probable cause a faulty radio unit, and recommended course of action is to replace the radio unit."
|
||
::= { hzIduRadioAlarmsEntry 8 }
|
||
|
||
hzIduRadioPowerAmpCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduRadioAlarmsEntry 9 }
|
||
|
||
hzIduRadioExcessiveTxCableLoss OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION ""
|
||
::= { hzIduRadioAlarmsEntry 10 }
|
||
hzIduRadioExcessiveTxCableLossCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduRadioAlarmsEntry 11 }
|
||
|
||
hzIduRadioRslBelowThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The minimum radio receive signal level threshold has been crossed. The severity is major, the probable cause is physical interference in the air link path or misalignment of the radios or severe weather conditions, and recommended course of action is to check the line of site between the air pair nodes."
|
||
::= { hzIduRadioAlarmsEntry 12 }
|
||
|
||
hzIduRadioRslBelowThresholdCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduRadioAlarmsEntry 13 }
|
||
|
||
hzIduRadioHighPowerOptionM1 OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This applies to High Power Radios only. Indicates Power Amp Alarm (M1)."
|
||
|
||
::= { hzIduRadioAlarmsEntry 14 }
|
||
|
||
hzIduRadioHighPowerOptionM1Counts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduRadioAlarmsEntry 15 }
|
||
|
||
hzIduRadioHighPowerOptionM2 OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This applies to High Power Radios only. Indicates Power Amp Alarm (M2)."
|
||
|
||
::= { hzIduRadioAlarmsEntry 16 }
|
||
|
||
hzIduRadioHighPowerOptionM2Counts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
::= { hzIduRadioAlarmsEntry 17 }
|
||
|
||
hzIduRadioHighPowerTxDetector OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This applies to High Power Radios only. Indicates minimum power threshold has not been surpassed."
|
||
|
||
::= { hzIduRadioAlarmsEntry 18 }
|
||
|
||
hzIduRadioHighPowerTxDetectorCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
|
||
::= { hzIduRadioAlarmsEntry 19 }
|
||
|
||
hzIduRadioAtpcConfigMismatch OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The pair of the systems don't have same ATPC configurations. On one side ATPC is enabled, but on the other side ATPC is not enabled. "
|
||
|
||
::= { hzIduRadioAlarmsEntry 20 }
|
||
|
||
hzIduRadioAtpcConfigMismatchCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
|
||
::= { hzIduRadioAlarmsEntry 21 }
|
||
|
||
|
||
hzIduRadioRedundancySerialNumMismatch OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The radio serial number programmed in flash and radio do not match."
|
||
|
||
::= { hzIduRadioAlarmsEntry 22 }
|
||
|
||
hzIduRadioRedundancySerialNumMismatchCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
|
||
::= { hzIduRadioAlarmsEntry 23 }
|
||
|
||
hzIduRadioExcessiveTxCableLossChange OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Cable loss change exceeds the threshold."
|
||
|
||
::= { hzIduRadioAlarmsEntry 24 }
|
||
|
||
hzIduRadioExcessiveTxCableLossChangeCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
|
||
::= { hzIduRadioAlarmsEntry 25 }
|
||
hzIduRadioExcessiveRxCableLoss OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Rx gain can not be adjusted to desired value."
|
||
|
||
::= { hzIduRadioAlarmsEntry 26 }
|
||
|
||
hzIduRadioExcessiveRxCableLossCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
|
||
::= { hzIduRadioAlarmsEntry 27 }
|
||
|
||
hzIduRadioAtpcTxAtMaxPower OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "ATPC auto-disabled (transmitting at coordinated power)."
|
||
::= { hzIduRadioAlarmsEntry 28 }
|
||
|
||
hzIduRadioAtpcTxAtMaxPowerCounts OBJECT-TYPE
|
||
SYNTAX Counter
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
|
||
|
||
::= { hzIduRadioAlarmsEntry 29 }
|
||
--
|
||
-- TRAP INFORMATION HOSTS, ENABLE/DISABLE
|
||
--
|
||
hzIduSnmpTrapHostTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduSnmpTrapHostEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Table containing SNMP trap host entries."
|
||
::= { hzIduTrapConfig 1 }
|
||
|
||
hzIduSnmpTrapHostEntry OBJECT-TYPE
|
||
SYNTAX HzIduSnmpTrapHostEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "The snmp trap host entry containing all the trap host information"
|
||
INDEX { hzIduSnmpTrapHostIndex }
|
||
::= { hzIduSnmpTrapHostTable 1 }
|
||
|
||
HzIduSnmpTrapHostEntry ::= SEQUENCE {
|
||
hzIduSnmpTrapHostIndex INTEGER,
|
||
hzIduSnmpTrapHostMode INTEGER,
|
||
hzIduSnmpTrapHostIpAddress IpAddress,
|
||
hzIduSnmpTrapHostCommunityName DisplayString,
|
||
hzIduSnmpTrapHostActivated INTEGER
|
||
}
|
||
|
||
|
||
hzIduSnmpTrapHostIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each trap host. "
|
||
::= { hzIduSnmpTrapHostEntry 1 }
|
||
|
||
|
||
hzIduSnmpTrapHostMode OBJECT-TYPE
|
||
SYNTAX INTEGER { static ( 1 ) , dns ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates how the snmp trap host is obtained for the system."
|
||
DEFVAL { static }
|
||
::= { hzIduSnmpTrapHostEntry 2 }
|
||
|
||
|
||
hzIduSnmpTrapHostIpAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates snmp trap host IP address. "
|
||
::= { hzIduSnmpTrapHostEntry 3 }
|
||
|
||
|
||
|
||
hzIduSnmpTrapHostCommunityName OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The community string name used in Traps."
|
||
::= { hzIduSnmpTrapHostEntry 4 }
|
||
|
||
|
||
hzIduSnmpTrapHostActivated OBJECT-TYPE
|
||
SYNTAX INTEGER { notActive ( 1 ) , active ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether traps are to be sent to this specific host or not"
|
||
DEFVAL { notActive }
|
||
::= { hzIduSnmpTrapHostEntry 5 }
|
||
|
||
|
||
|
||
--
|
||
-- SNMP V3 TRAP HOST TABLE
|
||
--
|
||
|
||
hzIduSnmpV3TrapHostsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduSnmpV3TrapHostsEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Table containing snmp V3 trap host entries"
|
||
::= { hzIduTrapConfig 2 }
|
||
|
||
hzIduSnmpV3TrapHostsEntry OBJECT-TYPE
|
||
SYNTAX HzIduSnmpV3TrapHostsEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Contains the snmp v3 trap host information"
|
||
INDEX { hzIduSnmpV3TrapHostsIndex }
|
||
::= { hzIduSnmpV3TrapHostsTable 1 }
|
||
|
||
HzIduSnmpV3TrapHostsEntry ::= SEQUENCE {
|
||
hzIduSnmpV3TrapHostsIndex INTEGER,
|
||
snmpV3TrapHostIpAddress IpAddress,
|
||
snmpV3TrapHostUserName DisplayString,
|
||
snmpV3TrapHostAuthProtocol INTEGER,
|
||
snmpV3TrapHostAuthPassword DisplayString,
|
||
snmpV3TrapHostPrivProtocol INTEGER,
|
||
snmpV3TrapHostPrivPassword DisplayString,
|
||
snmpV3TrapHostActivated INTEGER
|
||
}
|
||
|
||
hzIduSnmpV3TrapHostsIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each v3 trap host."
|
||
::= { hzIduSnmpV3TrapHostsEntry 1 }
|
||
|
||
snmpV3TrapHostIpAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates snmp trap host IP address. "
|
||
::= { hzIduSnmpV3TrapHostsEntry 2 }
|
||
|
||
snmpV3TrapHostUserName OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The user name of the v3 trap host."
|
||
::= { hzIduSnmpV3TrapHostsEntry 3 }
|
||
|
||
|
||
snmpV3TrapHostAuthProtocol OBJECT-TYPE
|
||
SYNTAX INTEGER { noAuth ( 1 ) , md5 ( 2 ), sha(3) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The authentication alogorithm used by the v3 trap host."
|
||
::= { hzIduSnmpV3TrapHostsEntry 4 }
|
||
|
||
snmpV3TrapHostAuthPassword OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The authentication password of the v3 trap host."
|
||
::= { hzIduSnmpV3TrapHostsEntry 5 }
|
||
|
||
snmpV3TrapHostPrivProtocol OBJECT-TYPE
|
||
SYNTAX INTEGER { noPriv ( 1 ) , des ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The privacy encryption alogorithm used by the v3 trap host."
|
||
::= { hzIduSnmpV3TrapHostsEntry 6 }
|
||
|
||
snmpV3TrapHostPrivPassword OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The privacy password of the v3 trap host."
|
||
::= { hzIduSnmpV3TrapHostsEntry 7 }
|
||
|
||
snmpV3TrapHostActivated OBJECT-TYPE
|
||
SYNTAX INTEGER { notActive ( 1 ) , active ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether a specific v3 trap host is allowed to access the system"
|
||
DEFVAL { notActive }
|
||
::= { hzIduSnmpV3TrapHostsEntry 8 }
|
||
|
||
-- ----------------------------
|
||
-- TRAP ENABLE
|
||
-- ----------------------------
|
||
hzIduTrapEnable OBJECT IDENTIFIER
|
||
::= { hzIduTrapConfig 3 }
|
||
|
||
hzIduColdStartTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 1 }
|
||
|
||
hzIduLinkDownTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 2 }
|
||
|
||
hzIduLinkUpTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 3 }
|
||
|
||
hzIduExplicitAuthenticationFailureTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 4 }
|
||
|
||
|
||
hzIduAamConfigMismatchTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Enables or disables the aamConfigMismatch trap. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 5 }
|
||
|
||
|
||
hzIduAamActiveTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Enables or disables the aamActive trap. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 6 }
|
||
|
||
|
||
hzIduAtpcConfigMismatchTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Enables or disables the trap. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 7 }
|
||
|
||
|
||
hzIduSntpServersUnreachableTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Enables or disables the trap. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 8 }
|
||
|
||
hzIduFrequencyFileInvalidTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Enables or disables the trap. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 9 }
|
||
|
||
|
||
hzIduEnetPortDroppedFramesThresholdExceedTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Enables or disables the trap."
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 10 }
|
||
|
||
hzIduEnetPortBandwidthUtilizationThresholdExceedTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Enables or disables the trap."
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 11 }
|
||
|
||
|
||
|
||
|
||
hzIduEnetPortRlsMismatchTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Enables or disables the trap. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 12 }
|
||
|
||
|
||
hzIduRLSQueueBasedShutdownActivatedTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Enables or disables the Queue-Based RLS Shutdown trap. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 13 }
|
||
|
||
hzIduModemRxLossOfSignalLockTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 14 }
|
||
|
||
hzIduModemTxLossOfSyncTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 15 }
|
||
|
||
hzIduModemSnrBelowThresholdTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 16 }
|
||
|
||
hzIduModemEqualizerStressExceedThresholdTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 17 }
|
||
|
||
hzIduModemChannelizedRslBelowThresholdTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Enables or disables the trap."
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 18 }
|
||
|
||
hzIduModemHardwareFaultTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 19 }
|
||
|
||
hzIduModemProgrammingErrorTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 20 }
|
||
|
||
hzIduTtyManagementSessionCommencedTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 21 }
|
||
|
||
hzIduTtyManagementSessionTerminatedTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 22 }
|
||
|
||
hzIduAtpcTxAtMaxPwrTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 23 }
|
||
|
||
hzIduRadioPLDROLostLockTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 24 }
|
||
|
||
hzIduRadioLostCommunicationTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 25 }
|
||
hzIduRadioMismatchTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 26 }
|
||
hzIduRadioPowerAmpTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 27 }
|
||
hzIduRadioExcessiveTxCableLossTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 28 }
|
||
hzIduHiPowerRadioDrainM1Trap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 29 }
|
||
hzIduHiPowerRadioDrainM2Trap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 30 }
|
||
hzIduHiPowerRadioTxDetectorTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 31 }
|
||
hzIduSecondaryRadioIsActiveTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 32 }
|
||
hzIduRedundancySerialNumberMisMatchTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 33 }
|
||
hzIduRadioFirmwareMismatchTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 34 }
|
||
hzIduSecondaryRadioNotdetectedTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 35 }
|
||
hzIduPrimaryRadioNotdetectedTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 36 }
|
||
hzIduFaultyPrimaryRadioTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 37 }
|
||
hzIduRadioExcessiveTxCableLossChangeTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 38 }
|
||
hzIduRadioExcessiveRxCableLossTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 39 }
|
||
hzIduRedundancyPrimaryPortNotSetTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 40 }
|
||
hzIduRedundancySecondaryPortIsActiveTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 41 }
|
||
hzIduRedundancyPrimaryPortFaultyTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 42 }
|
||
hzIduRedundancySecondaryPortFaultyTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 43 }
|
||
|
||
hzIduFan1FailedTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 44 }
|
||
hzIduFan2FailedTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 45 }
|
||
hzIduFan3FailedTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 46 }
|
||
hzIduFan4FailedTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether this trap is to be sent or not. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 47 }
|
||
hzIduPortRLSShutdownActivatedTrap OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Enables or disables the RLS Shutdown trap. "
|
||
DEFVAL { disabled }
|
||
::= { hzIduTrapEnable 48 }
|
||
|
||
|
||
--
|
||
-- SNMP MANAGERS
|
||
--
|
||
|
||
|
||
hzIduSnmpUserAccess OBJECT-TYPE
|
||
SYNTAX INTEGER { explicitManagers ( 1 ) , any ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies the user access to the system. If access is set to 'explicitManagers' then only managers with ip addresses set in snmpManagersTable will be able to gain SNMP access to the system. If access is set to 'any' then any manager will be able to gain SNMP access to the system"
|
||
::= { hzIduSnmp 1 }
|
||
|
||
hzIduSnmpManagerAnyCommunityName OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The community string name used by the 'any' manager."
|
||
::= { hzIduSnmp 2 }
|
||
|
||
hzIduSnmpSetRequests OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates whether SNMP SET requests are allowed."
|
||
DEFVAL { disabled }
|
||
::= { hzIduSnmp 3 }
|
||
|
||
|
||
|
||
hzIduSnmpManagersTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduSnmpManagersEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Table containing snmp manager entries"
|
||
::= { hzIduSnmp 4 }
|
||
|
||
hzIduSnmpManagersEntry OBJECT-TYPE
|
||
SYNTAX HzIduSnmpManagersEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Contains the snmp manager information"
|
||
INDEX { hzIduSnmpManagersIndex }
|
||
::= { hzIduSnmpManagersTable 1 }
|
||
|
||
HzIduSnmpManagersEntry ::= SEQUENCE {
|
||
hzIduSnmpManagersIndex INTEGER,
|
||
hzIduSnmpManagerIpAddress IpAddress,
|
||
hzIduSnmpManagerCommunityName DisplayString,
|
||
hzIduSnmpManagerActivated INTEGER
|
||
}
|
||
|
||
hzIduSnmpManagersIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each manager."
|
||
::= { hzIduSnmpManagersEntry 1 }
|
||
|
||
|
||
hzIduSnmpManagerIpAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The IP address of the Manager."
|
||
::= { hzIduSnmpManagersEntry 2 }
|
||
|
||
|
||
hzIduSnmpManagerCommunityName OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The community string name used by the manager."
|
||
::= { hzIduSnmpManagersEntry 3 }
|
||
|
||
|
||
hzIduSnmpManagerActivated OBJECT-TYPE
|
||
SYNTAX INTEGER { notActive ( 1 ) , active ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether a specific manager is allowed to access the system"
|
||
DEFVAL { notActive }
|
||
::= { hzIduSnmpManagersEntry 4 }
|
||
hzIduSnmpV3ManagersTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduSnmpV3ManagersEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Table containing snmp V3 manager entries"
|
||
::= { hzIduSnmp 5 }
|
||
|
||
hzIduSnmpV3ManagersEntry OBJECT-TYPE
|
||
SYNTAX HzIduSnmpV3ManagersEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Contains the snmp v3 manager information"
|
||
INDEX { hzIduSnmpV3ManagersIndex }
|
||
::= { hzIduSnmpV3ManagersTable 1 }
|
||
|
||
HzIduSnmpV3ManagersEntry ::= SEQUENCE {
|
||
hzIduSnmpV3ManagersIndex INTEGER,
|
||
hzIduSnmpV3ManagerUserName DisplayString,
|
||
hzIduSnmpV3ManagerAuthProtocol INTEGER,
|
||
hzIduSnmpV3ManagerAuthPassword DisplayString,
|
||
hzIduSnmpV3ManagerPrivProtocol INTEGER,
|
||
hzIduSnmpV3ManagerPrivPassword DisplayString,
|
||
hzIduSnmpV3ManagerActivated INTEGER
|
||
}
|
||
|
||
hzIduSnmpV3ManagersIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each v3 manager."
|
||
::= { hzIduSnmpV3ManagersEntry 1 }
|
||
|
||
|
||
hzIduSnmpV3ManagerUserName OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The user name of the v3 Manager."
|
||
::= { hzIduSnmpV3ManagersEntry 2 }
|
||
|
||
|
||
hzIduSnmpV3ManagerAuthProtocol OBJECT-TYPE
|
||
SYNTAX INTEGER { noAuth ( 1 ) , md5 ( 2 ), sha(3) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The authentication alogorithm used by the v3 manager."
|
||
::= { hzIduSnmpV3ManagersEntry 3 }
|
||
|
||
hzIduSnmpV3ManagerAuthPassword OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The authentication password of the v3 Manager."
|
||
::= { hzIduSnmpV3ManagersEntry 4 }
|
||
|
||
hzIduSnmpV3ManagerPrivProtocol OBJECT-TYPE
|
||
SYNTAX INTEGER { noPriv ( 1 ) , des ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The privacy encryption alogorithm used by the v3 manager."
|
||
::= { hzIduSnmpV3ManagersEntry 5 }
|
||
|
||
hzIduSnmpV3ManagerPrivPassword OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The privacy password of the v3 Manager."
|
||
::= { hzIduSnmpV3ManagersEntry 6 }
|
||
|
||
hzIduSnmpV3ManagerActivated OBJECT-TYPE
|
||
SYNTAX INTEGER { notActive ( 1 ) , active ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies whether a specific v3 manager is allowed to access the system"
|
||
DEFVAL { notActive }
|
||
::= { hzIduSnmpV3ManagersEntry 7 }
|
||
|
||
|
||
-- ------------------------------
|
||
-- hzIduManagementSessions
|
||
-- ------------------------------
|
||
|
||
hzIduTtySessionUserTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduTtySessionUserEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of Wireless Interface Radios"
|
||
::= { hzIduManagementSessions 1 }
|
||
|
||
hzIduTtySessionUserEntry OBJECT-TYPE
|
||
SYNTAX HzIduTtySessionUserEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A Wireless Interface Radio"
|
||
INDEX { hzIduTtySessionUserIndex }
|
||
::= { hzIduTtySessionUserTable 1 }
|
||
|
||
HzIduTtySessionUserEntry ::= SEQUENCE {
|
||
hzIduTtySessionUserIndex INTEGER,
|
||
hzIduTtySessionUserName DisplayString,
|
||
hzIduTtySessionUserConnectionType INTEGER,
|
||
hzIduTtySessionUserState INTEGER
|
||
}
|
||
|
||
hzIduTtySessionUserIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { user1 ( 1 ), user2 ( 2 ), user3 ( 3 ), user4 ( 4 ), user5 ( 5 ), user6 ( 6 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each user."
|
||
::= { hzIduTtySessionUserEntry 1 }
|
||
|
||
hzIduTtySessionUserName OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The username of a management session using Telnet or HTTP. The session state variable must be checked to determine if the management session is currently in progress."
|
||
::= { hzIduTtySessionUserEntry 2 }
|
||
|
||
hzIduTtySessionUserConnectionType OBJECT-TYPE
|
||
SYNTAX INTEGER { informationNotAvailable ( 1 ) , serialPort ( 2 ) , enetPort2 ( 3 ) , enetPort1 ( 4 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The physical port used to log in to the system. The serial port is always local to the equipment. The 10BaseT connector may be local, or remote, depending on if the configuration of network management port. The inband connection is the port carrying customer traffic."
|
||
::= { hzIduTtySessionUserEntry 3 }
|
||
|
||
hzIduTtySessionUserState OBJECT-TYPE
|
||
SYNTAX INTEGER { informationNotAvailable ( 1 ) , sessionTerminated ( 2 ) , sessionInProgress ( 3 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The state of the session. The session is inProgress if the user is currently logged into the system. The session is terminated if the user has logged out of the system."
|
||
::= { hzIduTtySessionUserEntry 4 }
|
||
|
||
--
|
||
-- HTTPS group
|
||
--
|
||
|
||
hzIduHttpEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates whether HTTP is enabled."
|
||
DEFVAL { disabled }
|
||
::= { hzIduHttp 1 }
|
||
|
||
hzIduHttpSecure OBJECT IDENTIFIER
|
||
::= { hzIduHttp 2 }
|
||
|
||
|
||
hzIduHttpSecureCertificateStatus OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 100 ) )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Returns the HTTPS certificate status"
|
||
::= { hzIduHttpSecure 1 }
|
||
|
||
|
||
hzIduHttpSecureAccessForAdminUsers OBJECT-TYPE
|
||
SYNTAX INTEGER { off( 1 ), on ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "the HTTPS access requirement for Admin user group."
|
||
::= { hzIduHttpSecure 2 }
|
||
|
||
hzIduHttpSecureAccessForNocUsers OBJECT-TYPE
|
||
SYNTAX INTEGER { off( 1 ), on ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "the HTTPS access requirement for Noc user group."
|
||
::= { hzIduHttpSecure 3 }
|
||
|
||
hzIduHttpSecureAccessForSuperUsers OBJECT-TYPE
|
||
SYNTAX INTEGER { off( 1 ), on ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "the HTTPS access requirement for Super user group."
|
||
::= { hzIduHttpSecure 4 }
|
||
|
||
|
||
--
|
||
-- Giga Ethernet Qos
|
||
--
|
||
hzIduQosEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates whether QOS is enabled."
|
||
DEFVAL { disabled }
|
||
::= { hzIduQos 1 }
|
||
|
||
hzIduCosType OBJECT-TYPE
|
||
SYNTAX INTEGER { cosVlan ( 1 ) , cosQinQiTag ( 2 ), cosQinQoTag ( 3 )}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates the class of service tag type. Based on the setting Horizon will use the CoS value in the VLAN tag, or Q-in-Q inner VLAN tag, or Q-in-Q outer VLAN tag."
|
||
DEFVAL { cosVlan }
|
||
::= { hzIduQos 2 }
|
||
|
||
|
||
--
|
||
-- 802.1p priorities assignment.
|
||
--
|
||
hzIduCoSQinQiTag OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Sets the value of the Q-in-Q inner tag. This tag is also used to classify the non-Q-in-Q VLAN. Default value is 0x8100."
|
||
DEFVAL { 0 }
|
||
::= { hzIduQos 3 }
|
||
|
||
hzIduCoSQinQoTag OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Sets the value of the Q-in-Q outer VLAN tag. Default value is 0x8100."
|
||
DEFVAL { 0 }
|
||
::= { hzIduQos 4 }
|
||
|
||
hzIduCosQueueMapping OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 15 .. 32 ) )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "User queue assignments for CoS values 0 to 7.
|
||
There are 4 coS queues. Their corresponding
|
||
queue numbers are 1,2, 3, where 1 is the lowest priority queue and
|
||
4 is the highest priority queue.
|
||
CoS to queue mapping example: 1 1 2 2 3 3 4 4."
|
||
::= { hzIduQos 5 }
|
||
|
||
|
||
|
||
--
|
||
-- Queue operation mode
|
||
--
|
||
hzIduCosExpediteQueue OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ), enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "This sets the user queue operation mode. (a) In expedite mode,
|
||
any Queue can be assigned 100% of CIR. Queue 4 is serviced first
|
||
and queue 1 is servcied last.(b) In non expedite mode, the sum of all CIRs
|
||
must be equal to 100%. In this mode higher priority queues
|
||
will be serviced first until that queue is emptied or
|
||
the defined CIR is reached."
|
||
DEFVAL { 1 }
|
||
::= { hzIduQos 6 }
|
||
|
||
--
|
||
-- user queues configuration.
|
||
--
|
||
|
||
hzIduCosQueueCIR OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Committed Information Rate (CIR) assignments for CoS queues
|
||
1 to 4. CIR is assigned as the percentage of system current speed.
|
||
When expedite queue is enabled any queue can be assigned 100% bandwidth.
|
||
When expedite queue is disabled the sum of CIR of all queues should be 100."
|
||
|
||
::= { hzIduQos 7 }
|
||
|
||
|
||
hzIduCosQueueCBS OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Comitted Burst Size (CBS) for CoS queues 1 to 4. CBS is the percentage
|
||
of total packet buffer size. The sum of CBS's of all 4
|
||
queues must be equal to 100. Minimum CBS assignable to any queue
|
||
is 1."
|
||
|
||
::= { hzIduQos 8 }
|
||
|
||
|
||
hzIduCosDefaultValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0 .. 7)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Default CoS value assigned to the ethernet
|
||
frames that don't have VLAN or Q-in-Q tag."
|
||
DEFVAL { 0 }
|
||
::= { hzIduQos 9 }
|
||
|
||
hzIduCutThroughProcessing OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Sets cut through processing on/off."
|
||
::= { hzIduQos 10 }
|
||
|
||
--
|
||
-- hzIduCosWfq
|
||
--
|
||
|
||
hzIduQosPolicy OBJECT-TYPE
|
||
SYNTAX INTEGER { strict-priority ( 1 ) , wfq ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Sets the Qos policy."
|
||
::= { hzIduQos 11 }
|
||
|
||
hzIduCosWfqWeight OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The weight assigned to each of the 4 cos queue. The wireless bandwidth is distributed amongst the
|
||
queues proportional to their weight.
|
||
The weights have values from 0-15, where 0 is the lowest weight and
|
||
15 is the highest weight.
|
||
Setting the Cos weight example: 1 2 3 4."
|
||
::= { hzIduQos 12 }
|
||
|
||
|
||
--
|
||
-- hzIduRapidLinkShutdown
|
||
--
|
||
|
||
|
||
|
||
hzIduRlsEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The Rapid Link Shutdown feature: enabled or disabled.
|
||
Changing this option requires a system reset."
|
||
DEFVAL { disabled }
|
||
::= { hzIduRapidLinkShutdown 1 }
|
||
|
||
hzIduRlsHardFaultMonitor OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Enable the rlsHardFaultMonitor for rapid detection of severely degrade link. When disabled
|
||
only the RLS Link Degrade Monitor is used."
|
||
DEFVAL { off }
|
||
::= { hzIduRapidLinkShutdown 2 }
|
||
|
||
hzIduRlsWirelessPortOption OBJECT-TYPE
|
||
SYNTAX INTEGER { anyport ( 1 ) , bothports ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "anyport - If the IDU is operating with two wireless ports and any one of the wireless ports goes down disables the ethernet port.
|
||
bothports - In the above condition, this feature disables the ehternet traffic through the faulty wireless link but continuously send
|
||
ethernet traffic through the other good wireless port. If the remaining wireless port also exceeds the error thereshold, ethernet port
|
||
will be disabled"
|
||
DEFVAL { off }
|
||
::= { hzIduRapidLinkShutdown 3 }
|
||
|
||
hzIduRlsAutomaticLinkReestablish OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "If this feature is enabled, the link will be automatically reestablished
|
||
If this feature is disabled, the user must explicitly use the manualReestablish object
|
||
to bring the link back up"
|
||
DEFVAL { disabled }
|
||
::= { hzIduRapidLinkShutdown 4 }
|
||
|
||
|
||
hzIduRlsManualLinkReestablish OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "This object is writeable ONLY if automaticLinkReestablish is set to disabled.
|
||
The user explicitly brings the link back up by setting this object to enabled.
|
||
The user explicitly brings the link down by setting this object to disabled.
|
||
to bring the link back up"
|
||
DEFVAL { disabled }
|
||
::= { hzIduRapidLinkShutdown 5 }
|
||
|
||
|
||
|
||
hzIduWriteRlsMonitorParametersToSystem OBJECT-TYPE
|
||
SYNTAX INTEGER { enabled ( 1 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "This writes RLS soft and hard fault monitor parameters to RAM
|
||
Reading this object returns '1'."
|
||
DEFVAL { 0 }
|
||
::= { hzIduRapidLinkShutdown 6 }
|
||
|
||
hzIduRlsDroppedFramesThresholdOverride OBJECT-TYPE
|
||
SYNTAX INTEGER { enabled ( 1 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "If the Ethernet is down due to Queue-Based Rls shutdown, this will bring the ethernet back and obey the queue settings.
|
||
Reading this object returns '1'."
|
||
DEFVAL { 0 }
|
||
::= { hzIduRapidLinkShutdown 7 }
|
||
|
||
hzIduRlsDroppedFramesThresholdTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduRlsDroppedFramesThresholdEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of RLS Queue Monitor Parameters"
|
||
::= { hzIduRapidLinkShutdown 8 }
|
||
|
||
hzIduRlsDroppedFramesThresholdEntry OBJECT-TYPE
|
||
SYNTAX HzIduRlsDroppedFramesThresholdEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "RLS Queue Parameters "
|
||
INDEX { hzIduRlsDroppedFramesThresholdIndex }
|
||
::= { hzIduRlsDroppedFramesThresholdTable 1 }
|
||
|
||
HzIduRlsDroppedFramesThresholdEntry ::= SEQUENCE {
|
||
hzIduRlsDroppedFramesThresholdIndex INTEGER,
|
||
hzIduRlsAllowedDroppedFrameRateValue DisplayString,
|
||
hzIduRlsDroppedFrameMonitorPeriod INTEGER
|
||
}
|
||
|
||
|
||
|
||
|
||
hzIduRlsDroppedFramesThresholdIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { queue-1 ( 1 ), queue-2 ( 2 ), queue-3 ( 3 ), queue-4 ( 4 )}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each interface. "
|
||
::= { hzIduRlsDroppedFramesThresholdEntry 1 }
|
||
|
||
|
||
hzIduRlsAllowedDroppedFrameRateValue OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Maximum allowed ethernet frame drop rate. If the average drop rate exceeds this threshold in any of the 4 queues, the Ethernet port will be shut down.
|
||
This feture is availabe only with bothports option"
|
||
::= { hzIduRlsDroppedFramesThresholdEntry 2 }
|
||
|
||
hzIduRlsDroppedFrameMonitorPeriod OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The monitoring period in seconds. "
|
||
::= { hzIduRlsDroppedFramesThresholdEntry 3 }
|
||
|
||
hzIduRlsSoftFaultMonitorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduRlsSoftFaultMonitorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of RLS Soft Fault Monitor Parameters"
|
||
::= { hzIduRapidLinkShutdown 9 }
|
||
|
||
hzIduRlsSoftFaultMonitorEntry OBJECT-TYPE
|
||
SYNTAX HzIduRlsSoftFaultMonitorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "RLS Parameters for Soft Fault Monitoring"
|
||
INDEX { hzIduRlsSoftFaultMonitorIndex }
|
||
::= { hzIduRlsSoftFaultMonitorTable 1 }
|
||
|
||
HzIduRlsSoftFaultMonitorEntry ::= SEQUENCE {
|
||
hzIduRlsSoftFaultMonitorIndex INTEGER,
|
||
hzIduRlsEstablishErredFrameThreshold INTEGER,
|
||
hzIduRlsShutdownErredFrameThreshold INTEGER,
|
||
hzIduRlsEstablishNumberOfSamples INTEGER,
|
||
hzIduRlsShutdownNumberOfSamples INTEGER,
|
||
hzIduRlsEstablishSamplePeriod INTEGER,
|
||
hzIduRlsShutdownSamplePeriod INTEGER,
|
||
hzIduRlsQuickShutdownSamplePeriod INTEGER
|
||
}
|
||
|
||
|
||
|
||
|
||
hzIduRlsSoftFaultMonitorIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each interface. "
|
||
::= { hzIduRlsSoftFaultMonitorEntry 1 }
|
||
|
||
hzIduRlsEstablishErredFrameThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Maximum erred blocks, per sample, allowed for link establishment."
|
||
::= { hzIduRlsSoftFaultMonitorEntry 2 }
|
||
|
||
hzIduRlsShutdownErredFrameThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Minimum erred blocks, per sample, allowed before link shutdown."
|
||
::= { hzIduRlsSoftFaultMonitorEntry 3 }
|
||
|
||
hzIduRlsEstablishNumberOfSamples OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Minimum number of consecutive good samples required before link is established."
|
||
::= { hzIduRlsSoftFaultMonitorEntry 4 }
|
||
|
||
hzIduRlsShutdownNumberOfSamples OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Minimum number of consecutive erred samples before link is shutdown."
|
||
::= { hzIduRlsSoftFaultMonitorEntry 5 }
|
||
|
||
hzIduRlsEstablishSamplePeriod OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Period of Time, in milliseconds, for monitoring Establish Erred Frame Threshold."
|
||
::= { hzIduRlsSoftFaultMonitorEntry 6 }
|
||
|
||
hzIduRlsShutdownSamplePeriod OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Period of Time, in milliseconds, for monitoring Shutdown Erred Frame Threshold."
|
||
::= { hzIduRlsSoftFaultMonitorEntry 7 }
|
||
|
||
hzIduRlsQuickShutdownSamplePeriod OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Minimum number of milliseconds required to classify samples as erred."
|
||
::= { hzIduRlsSoftFaultMonitorEntry 8 }
|
||
|
||
|
||
|
||
hzIduHardFaultMonitorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduHardFaultMonitorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of RLS Hard Fault Monitor Parameters"
|
||
::= { hzIduRapidLinkShutdown 10 }
|
||
|
||
hzIduHardFaultMonitorEntry OBJECT-TYPE
|
||
SYNTAX HzIduHardFaultMonitorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "RLS Parameters for Hard Fault Monitoring"
|
||
INDEX { hzIduHardFaultMonitorIndex }
|
||
::= { hzIduHardFaultMonitorTable 1 }
|
||
|
||
HzIduHardFaultMonitorEntry ::= SEQUENCE {
|
||
hzIduHardFaultMonitorIndex INTEGER,
|
||
hzIduRlsHardFaultSamplePeriod INTEGER,
|
||
hzIduRlsHardFaultThreshold INTEGER
|
||
}
|
||
|
||
|
||
|
||
|
||
hzIduHardFaultMonitorIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each interface. "
|
||
::= { hzIduHardFaultMonitorEntry 1 }
|
||
|
||
|
||
hzIduRlsHardFaultSamplePeriod OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The period of time, in milliseconds, for which the
|
||
rlsFaultThreshold is applied."
|
||
::= { hzIduHardFaultMonitorEntry 2 }
|
||
|
||
hzIduRlsHardFaultThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Acceptalbe errored block rate in percent"
|
||
::= { hzIduHardFaultMonitorEntry 3 }
|
||
|
||
hzIduRlsReceiveSignalLevelMonitorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduRlsReceiveSignalLevelMonitorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of RLS RSL Monitor Parameters"
|
||
::= { hzIduRapidLinkShutdown 11 }
|
||
|
||
hzIduRlsReceiveSignalLevelMonitorEntry OBJECT-TYPE
|
||
SYNTAX HzIduRlsReceiveSignalLevelMonitorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "RLS RSL Monitor Parameters"
|
||
INDEX { hzIduRlsReceiveSignalLevelMonitorIndex }
|
||
::= { hzIduRlsReceiveSignalLevelMonitorTable 1 }
|
||
|
||
HzIduRlsReceiveSignalLevelMonitorEntry ::= SEQUENCE {
|
||
hzIduRlsReceiveSignalLevelMonitorIndex INTEGER,
|
||
hzIduRlsMakeRslMonitorRslValue DisplayString,
|
||
hzIduRlsMakeRslMonitorPeriod INTEGER
|
||
}
|
||
|
||
|
||
|
||
|
||
hzIduRlsReceiveSignalLevelMonitorIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each interface. "
|
||
::= { hzIduRlsReceiveSignalLevelMonitorEntry 1 }
|
||
|
||
|
||
hzIduRlsMakeRslMonitorRslValue OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The RSL threshold, in dBm. When Link is inactive and if RSL
|
||
is higher than this threshold for a desired
|
||
period, the link will become active."
|
||
::= { hzIduRlsReceiveSignalLevelMonitorEntry 2 }
|
||
|
||
hzIduRlsMakeRslMonitorPeriod OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The desired period, in seconds. When Link is inactive and if RSL
|
||
is higher than the desired threshold for this
|
||
period, the link will become active."
|
||
::= { hzIduRlsReceiveSignalLevelMonitorEntry 3 }
|
||
|
||
--
|
||
-- rlsStatus
|
||
--
|
||
hzIduRlsStatus OBJECT IDENTIFIER
|
||
::= { hzIduRapidLinkShutdown 12 }
|
||
|
||
hzIduRlsCurrentDroppedFramesTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduRlsCurrentDroppedFramesEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of RLS Currently Observed Queue Monitor Parameters"
|
||
::= { hzIduRlsStatus 1 }
|
||
|
||
hzIduRlsCurrentDroppedFramesEntry OBJECT-TYPE
|
||
SYNTAX HzIduRlsCurrentDroppedFramesEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "RLS Currently Observed Queue Monitor Parameters"
|
||
INDEX { hzIduRlsCurrentDroppedFramesIndex }
|
||
::= { hzIduRlsCurrentDroppedFramesTable 1 }
|
||
|
||
HzIduRlsCurrentDroppedFramesEntry ::= SEQUENCE {
|
||
hzIduRlsCurrentDroppedFramesIndex INTEGER,
|
||
hzIduRlsCurrentDroppedFramesRateValue DisplayString,
|
||
hzIduRlsCurrentDroppedFrameMonitorPeriod INTEGER,
|
||
hzIduRlsCurrentQueueStatus DisplayString
|
||
}
|
||
|
||
|
||
|
||
|
||
hzIduRlsCurrentDroppedFramesIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { queue-1 ( 1 ), queue-2 ( 2 ), queue-3 ( 3 ), queue-4 ( 4 )}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each interface. "
|
||
::= { hzIduRlsCurrentDroppedFramesEntry 1 }
|
||
|
||
|
||
hzIduRlsCurrentDroppedFramesRateValue OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "RLS Current Ethernet Frame drop rate"
|
||
::= { hzIduRlsCurrentDroppedFramesEntry 2 }
|
||
|
||
hzIduRlsCurrentDroppedFrameMonitorPeriod OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Queue Monitoring time"
|
||
::= { hzIduRlsCurrentDroppedFramesEntry 3 }
|
||
|
||
hzIduRlsCurrentQueueStatus OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Queue Status - OK: drop rate is within the threshold, Activated: Exceeded the drop threshold"
|
||
::= { hzIduRlsCurrentDroppedFramesEntry 4 }
|
||
|
||
hzIduRlsStatusTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduRlsStatusEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "A table of RLS Parameters and states"
|
||
::= { hzIduRlsStatus 2 }
|
||
|
||
hzIduRlsStatusEntry OBJECT-TYPE
|
||
SYNTAX HzIduRlsStatusEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "RLS Parameters and states"
|
||
INDEX { hzIduRlsStatusIndex }
|
||
::= { hzIduRlsStatusTable 1 }
|
||
|
||
HzIduRlsStatusEntry ::= SEQUENCE {
|
||
hzIduRlsStatusIndex INTEGER,
|
||
hzIduRlsOption DisplayString,
|
||
hzIduRlsState DisplayString,
|
||
hzIduRlsMismatchState DisplayString,
|
||
hzIduDegradeMonitorState DisplayString,
|
||
hzIduHardFaultMonitorState DisplayString,
|
||
hzIduMakeRslThresholdState DisplayString,
|
||
hzIduPeerRlsState DisplayString,
|
||
hzIduRadioInterfaceState DisplayString,
|
||
hzIduNetworkInterfaceState DisplayString,
|
||
hzIduUserConfiguredEstablishFer DisplayString,
|
||
hzIduMinimumAchievableEstablishFer DisplayString,
|
||
hzIduUserConfiguredShutdownFer DisplayString,
|
||
hzIduMinimumAchievableShutdownFer DisplayString,
|
||
hzIduUserConfiguredEstablishMonitorTime INTEGER,
|
||
hzIduActualEstablishMonitorTime INTEGER,
|
||
hzIduUserConfiguredShutdownMonitorTime INTEGER,
|
||
hzIduActualShutdownMonitorTime INTEGER
|
||
}
|
||
|
||
|
||
|
||
|
||
hzIduRlsStatusIndex OBJECT-TYPE
|
||
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each interface. "
|
||
::= { hzIduRlsStatusEntry 1 }
|
||
|
||
|
||
|
||
|
||
hzIduRlsOption OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "RLS Option. On Basic: RLS enabled with base degrade monitoring;
|
||
On Advanced: RLS enabled with hard fault monitoring;
|
||
On Anyport: If any one of the wireless links exceeds the threshold Ehternet Port will be shut down
|
||
On Bothports: Both wireless links should exceed the threshold to bring the Ethernet Port down
|
||
Off: Entire RLS feature disabled."
|
||
::= { hzIduRlsStatusEntry 2 }
|
||
|
||
|
||
|
||
hzIduRlsState OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Rapid Link Shutdown State. If the state is activated, that means
|
||
The wireless link is down for Ethernet traffic; If the state is inactivated, that means that
|
||
wireless link is up for Ethernet traffic."
|
||
::= { hzIduRlsStatusEntry 3 }
|
||
|
||
hzIduRlsMismatchState OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "RLS Mismatch State. If the state is activated, that means RLS
|
||
configuration is mismatched with peer. If the state is OK,
|
||
that means RLS configuration is matched with peer."
|
||
::= { hzIduRlsStatusEntry 4 }
|
||
|
||
hzIduDegradeMonitorState OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Degrade Monitor State. If the state is activated, that means
|
||
the RLS Degrade Monitor is asserting the link down. If the
|
||
state is OK, that means the RLS Degrade Monitor is asserting
|
||
the link up."
|
||
::= { hzIduRlsStatusEntry 5 }
|
||
|
||
hzIduHardFaultMonitorState OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Hard Fault Monitor State. If the state is activated, that means
|
||
the Hard Fault Monitor is asserting the link down. If the state
|
||
is OK, that means the RLS Hard Fault Monitor is asserting the
|
||
link up."
|
||
::= { hzIduRlsStatusEntry 6 }
|
||
|
||
hzIduMakeRslThresholdState OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Make RSL Threshold State. If the state is not met, that means the
|
||
RLS signal level is below the threshold value. If the state is OK,
|
||
that means the RLS signal level is above the threshold value."
|
||
::= { hzIduRlsStatusEntry 7 }
|
||
|
||
hzIduPeerRlsState OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Peer RLS State. If the state is activated, that means the peer has
|
||
activated RLS. If the state is OK, that means the Peer hasn't
|
||
activated RLS."
|
||
::= { hzIduRlsStatusEntry 8 }
|
||
|
||
hzIduRadioInterfaceState OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Radio Interface State. If the state is down, that means The radio
|
||
interface is not operational(muted,disconnected, not configured).
|
||
If the state is up, that means the radio interface is operational."
|
||
::= { hzIduRlsStatusEntry 9 }
|
||
|
||
hzIduNetworkInterfaceState OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Network Interface State. If the state is down, that means the network
|
||
interface (Ethernet/PHY) is not operational(disconnected, not
|
||
configured). If the state is up, that means the network interface
|
||
(Ethernet/PHY) is operational."
|
||
::= { hzIduRlsStatusEntry 10 }
|
||
|
||
hzIduUserConfiguredEstablishFer OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "User Configured Establish Frame Error Ratio required for the
|
||
link to be restored to service, set by the user. An example
|
||
value being '1.0E-7'."
|
||
::= { hzIduRlsStatusEntry 11 }
|
||
|
||
hzIduMinimumAchievableEstablishFer OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Minimum achievable Frame Error Ratio required for the link to be
|
||
restored to service. An example value being '1.0E-7'."
|
||
::= { hzIduRlsStatusEntry 12 }
|
||
|
||
hzIduUserConfiguredShutdownFer OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "User Configured Shutdown Frame Error Ratio required for the
|
||
link to remain in-service, set by the user. An example value
|
||
being '1.0E-7'."
|
||
::= { hzIduRlsStatusEntry 13 }
|
||
|
||
hzIduMinimumAchievableShutdownFer OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Minimum achievable Frame Error Ratio required for the link to
|
||
remain in-service. An example value being '1.0E-7'."
|
||
::= { hzIduRlsStatusEntry 14 }
|
||
|
||
hzIduUserConfiguredEstablishMonitorTime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "User Configured Establish Monitor Time, in milliseconds, for
|
||
which the 'User Configured Establish FER' must be achieved
|
||
to bring link into service, set by user"
|
||
::= { hzIduRlsStatusEntry 15 }
|
||
|
||
hzIduActualEstablishMonitorTime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Actual Establish Monitor Time, in milliseconds, for which the
|
||
'User Configured Establish FER' must be achieved to bring
|
||
link into service, it's a multiple of the establish sample
|
||
period required to observe the FER"
|
||
::= { hzIduRlsStatusEntry 16 }
|
||
|
||
hzIduUserConfiguredShutdownMonitorTime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "User Configured Shutdown Monitor Time, in milliseconds, for which
|
||
the 'User Configured Shutdown FER' must be met for the link to
|
||
remain in-service, set by user."
|
||
::= { hzIduRlsStatusEntry 17 }
|
||
|
||
hzIduActualShutdownMonitorTime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Actual Shutdown Monitor Time, in milliseconds, for which the 'User
|
||
Configured Shutdown FER' must be met for the link to remain
|
||
in-service, it's a multiple of the shutdown sample period required
|
||
to observe the FER"
|
||
::= { hzIduRlsStatusEntry 18 }
|
||
|
||
|
||
|
||
--
|
||
-- hzIduSntp
|
||
--
|
||
|
||
hzIduSntpEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates whether SNTP feature is enabled."
|
||
DEFVAL { enabled }
|
||
::= { hzIduSntp 1 }
|
||
|
||
hzIduSntpOffset OBJECT-TYPE
|
||
-- This value is shown in 10ths of hours
|
||
SYNTAX INTEGER ( -140 .. 140 )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "System time offset from GMT in tenths of hours. For example, an offset of 10 indicates 10 tenths, or 1 hour. An offset of 5 indicates half an hour."
|
||
DEFVAL { -40 }
|
||
::= { hzIduSntp 2 }
|
||
|
||
|
||
hzIduSntpServerTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduSntpServerEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Table containing sntp server entries"
|
||
::= { hzIduSntp 3 }
|
||
|
||
hzIduSntpServerEntry OBJECT-TYPE
|
||
SYNTAX HzIduSntpServerEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Contains the sntp server information"
|
||
INDEX { hzIduSntpServerIndex }
|
||
::= { hzIduSntpServerTable 1 }
|
||
|
||
HzIduSntpServerEntry ::= SEQUENCE {
|
||
hzIduSntpServerIndex INTEGER,
|
||
hzIduSntpServerIpAddress IpAddress,
|
||
hzIduSntpServerStatus INTEGER,
|
||
hzIduSntpServerStratum INTEGER
|
||
}
|
||
|
||
hzIduSntpServerIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each server."
|
||
::= { hzIduSntpServerEntry 1 }
|
||
|
||
|
||
hzIduSntpServerIpAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The IP address of the server."
|
||
::= { hzIduSntpServerEntry 2 }
|
||
|
||
|
||
hzIduSntpServerStatus OBJECT-TYPE
|
||
SYNTAX INTEGER { good (1) , failed (2) }
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The status of the sntp server."
|
||
::= { hzIduSntpServerEntry 3 }
|
||
|
||
|
||
hzIduSntpServerStratum OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Specifies the stratum of a server, 0 for failed server"
|
||
::= { hzIduSntpServerEntry 4 }
|
||
|
||
--
|
||
-- hzIduLogs
|
||
--
|
||
|
||
hzIduEventLogEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates whether event log is enabled."
|
||
DEFVAL { enabled }
|
||
::= { hzIduLogs 1 }
|
||
|
||
hzIduPerfmLogEnable OBJECT-TYPE
|
||
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Indicates whether performance log is enabled."
|
||
DEFVAL { enabled }
|
||
::= { hzIduLogs 2 }
|
||
|
||
hzIduPerfmLogInterval OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE ( 0 .. 10 ) )
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "Performance statistics are logged periodically by this interval. The interval can be up to 24:00:00 (24 hours) and as short as 00:00:15 (15 seconds)."
|
||
::= { hzIduLogs 3 }
|
||
|
||
--
|
||
-- hzIduRadius
|
||
--
|
||
hzIduRadiusSuperUserAuthentication OBJECT-TYPE
|
||
SYNTAX INTEGER { off ( 1 ) , on( 2 ) }
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION " The set strict mode on or off"
|
||
DEFVAL { off }
|
||
::= { hzIduRadius 1 }
|
||
|
||
hzIduRadiusServerTimeOut OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION " Timeout period for authentication requests"
|
||
DEFVAL { 0 }
|
||
::= { hzIduRadius 2 }
|
||
|
||
|
||
hzIduRadiusServerDeadTime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION " Time to declare an unresponsive server 'dead'"
|
||
DEFVAL { 0 }
|
||
::= { hzIduRadius 3 }
|
||
|
||
hzIduRadiusServerReTransmit OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "Maximum number of retransmits to an unresponsive server"
|
||
::= { hzIduRadius 4 }
|
||
|
||
|
||
|
||
hzIduRadiusServerTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF HzIduRadiusServerEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Table containing radius server entries"
|
||
::= { hzIduRadius 5 }
|
||
|
||
hzIduRadiusServerEntry OBJECT-TYPE
|
||
SYNTAX HzIduRadiusServerEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION "Contains the sntp server information"
|
||
INDEX { hzIduRadiusServerIndex }
|
||
::= { hzIduRadiusServerTable 1 }
|
||
|
||
HzIduRadiusServerEntry ::= SEQUENCE {
|
||
hzIduRadiusServerIndex INTEGER,
|
||
hzIduRadiusCfgdHostIpAddress IpAddress,
|
||
hzIduRadiusActiveHostIpAddress IpAddress
|
||
}
|
||
|
||
hzIduRadiusServerIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each server."
|
||
::= { hzIduRadiusServerEntry 1 }
|
||
|
||
|
||
hzIduRadiusCfgdHostIpAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION "The IP address of the configured radius server."
|
||
::= { hzIduRadiusServerEntry 2 }
|
||
|
||
|
||
hzIduRadiusActiveHostIpAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The IP address of the active radius server."
|
||
::= { hzIduRadiusServerEntry 3 }
|
||
|
||
--
|
||
-- TRAP DEFINITIONS
|
||
--
|
||
|
||
coldStart TRAP-TYPE
|
||
ENTERPRISE snmp
|
||
DESCRIPTION
|
||
"A coldStart trap signifies that the sending protocol entity is reinitializing itself such that the agent's configuration or the protocol entity implementation may be altered."
|
||
::= 0
|
||
|
||
-- for generic traps real trap value of linkDown is 2.
|
||
linkDown TRAP-TYPE
|
||
ENTERPRISE snmp
|
||
VARIABLES {ifIndex}
|
||
DESCRIPTION
|
||
"A linkDown trap signifies that the sending protocol entity recognizes a failure in one of the communication links represented in the agent's configuration."
|
||
::= 1
|
||
|
||
-- for generic traps real trap value of linkup is 3.
|
||
|
||
linkUp TRAP-TYPE
|
||
ENTERPRISE snmp
|
||
VARIABLES {ifIndex}
|
||
DESCRIPTION
|
||
"A linkUp trap signifies that the sending protocol entity recognizes that one of the communication links represented in the agent's configuration has come up."
|
||
::= 2
|
||
|
||
|
||
hzIduExplicitAuthenticationFailureV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Authentication of the peer horizon node has failed. The severity is critical, the probable cause is an incorrect authentication configuration on horizon faulty cable between the modem and radio, and recommended course of action is to check both ends of the link."
|
||
::= 3
|
||
|
||
hzIduExplicitAuthenticationFailureClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "The condition has cleared. The peer node is now authenticated."
|
||
::= 4
|
||
|
||
|
||
hzIduAamConfigMisMatchV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Adaptive modulation configuration mismatch"
|
||
::= 5
|
||
|
||
hzIduAamConfigMisMatchClearV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Adaptive modulation configuration mismatch cleared"
|
||
::= 6
|
||
|
||
hzIduAamActiveV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Adaptive modulation on and system running on lowest modulation"
|
||
::= 7
|
||
|
||
hzIduAamActiveClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Adaptive modulation on system running on higher modulation"
|
||
::= 8
|
||
|
||
hzIduAtpcConfigMismatchV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "ATPC is set to on at near end however in the far end it is set to off."
|
||
::= 9
|
||
|
||
hzIduAtpcConfigMismatchClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "ATPC configuration mismatch is cleared"
|
||
::= 10
|
||
|
||
hzIduSntpServersUnreachableV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Can't reach any of the sntp servers"
|
||
::= 11
|
||
|
||
hzIduSntpServersUnreachableClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "At least one of SNTP servers is reachable"
|
||
::= 12
|
||
|
||
|
||
hzIduFrequencyFileInvalidV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "When the executing frequency file is invalid,
|
||
this trap is generated."
|
||
::= 13
|
||
|
||
hzIduEnetPort1DroppedFramesThresholdExceededV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "The ethernet dropped frames threshold has been detected above its threshold value."
|
||
::= 14
|
||
|
||
hzIduEnetPort1DroppedFramesThresholdExceededClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "The condition has cleared.The ethernet dropped frames threshold is now below its threshold value."
|
||
::= 15
|
||
|
||
|
||
hzIduEnetPort1BwUtilizationThresholdExceededV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "The ethernet bandwidth threshold has been detected above its threshold value."
|
||
::= 16
|
||
|
||
hzIduEnetPort1BwUtilizationThresholdExceededClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "The condition has cleared. The ethernet bandwidth threshold is now below its threshold value."
|
||
::= 17
|
||
|
||
hzIduEnetPort1RlsMismatchV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "RLS mismatch"
|
||
::= 18
|
||
|
||
hzIduEnetPort1RlsMismatchClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "RLS mismatch cleared"
|
||
::= 19
|
||
|
||
hzIduRlsQueueBasedShutdownActivatedv1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "RLS Queue-Based shutdown is activated"
|
||
::= 20
|
||
|
||
hzIduRlsQueueBasedShutdownActivatedClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "RLS Queue-Based shutdown is not activated"
|
||
::= 21
|
||
|
||
hzIduModemRxLossOfSignalLockV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "Loss of signal lock from the demodulator. The severity is critical, the probable cause is lost synchronization with the far end, and recommended course of action is to check the operational state of both ends of the link."
|
||
::= 22
|
||
|
||
hzIduModemRxLossOfSignalLockClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "The condition has cleared. The demodulator is synchronized."
|
||
::= 23
|
||
|
||
hzIduModemTxLossOfSyncV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "Loss of sync bytes at the input of the modulator. The severity is critical, the probable cause is physical
|
||
interference in the air link, and recommended course of action is to check the line of site between the horizon nodes."
|
||
::= 24
|
||
|
||
hzIduModemTxLossOfSyncClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "Tx Loss of sync bytes cleared."
|
||
::= 25
|
||
|
||
|
||
hzIduModemSnrBelowThresholdV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "The demodulator SNR performance worse than programmed levels. The severity is major, the probable cause
|
||
is physical interference in the air link path or misalignment of the radios or severe weather conditions, and recommended course
|
||
of action is to check the line of site between the horizon nodes."
|
||
::= 26
|
||
|
||
hzIduModemSnrBelowThresholdClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "SNR performance back to normal."
|
||
::= 27
|
||
|
||
hzIduModemEqualizerStressExceedThresholdV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "Equalizer Stress measured within the demodulator exceeds the threshold value."
|
||
::= 28
|
||
|
||
hzIduModemEqualizerStressExceedThresholdClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "Equalizer Stress measured within the demodulator is within the threshold value."
|
||
::= 29
|
||
hzIduEnetPort1ChannelizedRslBelowThresholdV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "The RSL has been detected below its minimum threshold."
|
||
::= 30
|
||
|
||
hzIduEnetPort1ChannelizedRslBelowThresholdClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "The condition has cleared. RSL is now above its minimum threshold."
|
||
::= 31
|
||
|
||
hzIduModemHardwareFaultV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "Power supply circuitry failed. Should be sent for diagnosis."
|
||
::= 32
|
||
|
||
hzIduModemHardwareFaultClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "Power supply circuitry is in good condition."
|
||
::= 33
|
||
|
||
hzIduModemProgrammingErrorV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "Encountered problem while programming modem."
|
||
::= 34
|
||
|
||
hzIduModemProgrammingErrorClearedrV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "Problem encountered while programming modem is gone."
|
||
::= 35
|
||
|
||
hzIduTtySessionCommencedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES { hzIduTtySessionUserName,
|
||
hzIduTtySessionUserConnectionType }
|
||
|
||
DESCRIPTION "A person has successfully gained access to the ascii management port (telnet, local management port, or HTTP). The username is included in the Trap."
|
||
::= 36
|
||
|
||
hzIduTtySessionTerminatedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES { hzIduTtySessionUserName,
|
||
hzIduTtySessionUserConnectionType }
|
||
DESCRIPTION "A person has logged out of an ascii management port (telnet, local management port, or HTTP). The username is included in the Trap."
|
||
::= 37
|
||
|
||
hzIduAtpcTxAtMaxPwrV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "ATPC auto-disabled (transmitting at coordinated power)."
|
||
::= 38
|
||
|
||
hzIduAtpcTxAtMaxPwrClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "ATPC has been disabled."
|
||
::= 39
|
||
|
||
-- Radio Traps 50+ restored for IDU --
|
||
|
||
hzIduRadioPLDROLostLockV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "The PLDRO/LO has lost lock on the radio. The severity is critical, the probable cause a faulty radio unit within AirPair, and recommended course of action is to replace the radio unit"
|
||
::= 40
|
||
hzIduRadioPLDROLostLockClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "The radio PLDRO/LO lost lock condition has cleared."
|
||
::= 41
|
||
|
||
hzIduRadioLostCommunicationV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "RS232 communication lost between IDU and the radio. The severity is critical, the probable cause is a faulty cable between the modem and radio, and recommended course of action is to check the connection."
|
||
::= 42
|
||
hzIduRadioLostCommunicationClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "RS232 communication has been re-establisted between IDU and the radio."
|
||
::= 43
|
||
|
||
hzIduRadioMismatchV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "The radio connected to the IDU modem does not match the frequency programmed into the modem unit. The severity is major, the probable cause is an incorrectly programmed modem or an incorrect radio type connected to the modem, and recommended course of action is to check the modem frequency settings and radio hardware version number or serial number."
|
||
::= 44
|
||
hzIduRadioMismatchClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "The condition has cleared. The radio matches the programmed parameters in the modem."
|
||
::= 45
|
||
|
||
hzIduRadioPowerAmpV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "The power amplifier on the radio is not operating within normal operating specifications. The severity is critical, the probable cause a faulty radio unit, and recommended course of action is to replace the radio unit."
|
||
::= 46
|
||
hzIduRadioPowerAmpClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "The power amplifier on the radio is now operating within normal specifications"
|
||
::= 47
|
||
|
||
hzIduRadioExcessiveTxCableLossV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "The radio cannot compensate for the calculated amount of Tx Cable Loss."
|
||
::= 48
|
||
hzIduRadioExcessiveTxCableLossClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Excessive Tx Cable Loss cleared."
|
||
::= 49
|
||
|
||
hzIduHiPowerRadioDrainM1V1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "This applies to High Power Radios only. Indicates Power Amp Alarm (M1)."
|
||
::= 50
|
||
hzIduHiPowerRadioDrainM1ClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "This applies to High Power Radios only. Indicates Power Amp Alarm (M1) cleared."
|
||
::= 51
|
||
|
||
hzIduHiPowerRadioDrainM2V1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "This applies to High Power Radios only. Indicates Power Amp Alarm (M2)."
|
||
::= 52
|
||
hzIduHiPowerRadioDrainM2ClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "This applies to High Power Radios only. Indicates Power Amp Alarm (M2) cleared."
|
||
::= 53
|
||
|
||
hzIduHiPowerRadioTxDetectorV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "This applies to High Power Radios only. Indicates minimum power threshold has not been surpassed."
|
||
::= 54
|
||
hzIduHiPowerRadioTxDetectorClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "This applies to High Power Radios only. Indicates minimum power threshold alarm has cleared."
|
||
::= 55
|
||
|
||
hzIduSecondaryRadioIsActiveV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Radio redundancy on, secondary radio is active."
|
||
::= 56
|
||
hzIduSecondaryRadioIsActiveClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Radio redundancy, secondary radio is no longer active."
|
||
::= 57
|
||
|
||
hzIduRedundancySerialNumberMisMatchV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "The radio serial number programmed in flash and radio do not match."
|
||
::= 58
|
||
hzIduRedundancySerialNumberMisMatchClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "The radio serial number mismatch has cleared."
|
||
::= 59
|
||
|
||
hzIduRadioFirmwareMismatchV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "The radio connected to the IDU modem does not match the radio band or frequency bank specified by the user. As a result, the system
|
||
will not work."
|
||
::= 60
|
||
hzIduRadioFirmwareMismatchClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Radio Firmnware mismatch cleared."
|
||
::= 61
|
||
|
||
hzIduSecondaryRadioNotdetectedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Secondary radio not detected."
|
||
::= 62
|
||
hzIduSecondaryRadioNotdetectedClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "secondary Radio not detected alarm cleared."
|
||
::= 63
|
||
|
||
hzIduPrimaryRadioNotdetectedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Primary Radio not detected."
|
||
::= 64
|
||
hzIduPrimaryRadioNotdetectedClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Primary Radio not detected alarm cleared."
|
||
::= 65
|
||
|
||
hzIduFaultyPrimaryRadioV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Faulty Primary Radio."
|
||
::= 66
|
||
hzIduFaultyPrimaryRadioClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Faulty Primary Radio alarm cleared."
|
||
::= 67
|
||
|
||
hzIduRadioExcessiveTxCableLossChangeV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Radio - Excessive Tx cable loss change detected."
|
||
::= 68
|
||
hzIduRadioExcessiveTxCableLossChangeClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Radio - Excessive Tx cable loss change cleared."
|
||
::= 69
|
||
|
||
hzIduExcessiveRxCableLossV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Radio - Excessive receive cable loss detected."
|
||
::= 70
|
||
hzIduExcessiveRxCableLossClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduRadioAlarmsIndex}
|
||
DESCRIPTION "Radio - Excessive receive cable loss cleared."
|
||
::= 71
|
||
|
||
hzIduRedundancyPrimaryPortNotSetV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Redundancy: Primary Port not set."
|
||
::= 72
|
||
hzIduRedundancyPrimaryPortNotSetClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Redundancy: Primary Port not set - cleared."
|
||
::= 73
|
||
|
||
hzIduRedundancySecondaryPortIsActiveV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Redundancy: Secondary Port is Active."
|
||
::= 74
|
||
|
||
hzIduRedundancySecondaryPortIsActiveClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Redundancy: Secondary Port is no longer Active"
|
||
::= 75
|
||
|
||
hzIduRedundancyPrimaryPortFaultyV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Redundancy: Primary Port is Faulty."
|
||
::= 76
|
||
|
||
hzIduRedundancyPrimaryPortFaultyClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Redundancy: Primary Port is no longer Faulty."
|
||
::= 77
|
||
|
||
hzIduRedundancySecondaryPortFaultyV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Redundancy: Secondary Port is Faulty."
|
||
::= 78
|
||
|
||
hzIduRedundancySecondaryPortFaultyClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Redundancy: secondary Port is no longer Faulty."
|
||
::= 79
|
||
|
||
hzIduFan1FailedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Fan 1 has failed"
|
||
::= 80
|
||
|
||
hzIduFan1FailureClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "The Fan 1 Failure has Cleared"
|
||
::= 81
|
||
|
||
hzIduFan2FailedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Fan 2 has failed"
|
||
::= 82
|
||
|
||
hzIduFan2FailureClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "The Fan 2 Failure has Cleared"
|
||
::= 83
|
||
|
||
hzIduFan3FailedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Fan 3 has failed"
|
||
::= 84
|
||
|
||
hzIduFan3FailureClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "The Fan 3 Failure has Cleared"
|
||
::= 85
|
||
|
||
hzIduFan4FailedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "Fan 4 has failed"
|
||
::= 86
|
||
|
||
hzIduFan4FailureClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
DESCRIPTION "The Fan 4 Failure has Cleared"
|
||
::= 87
|
||
hzIduRlsShutdownActivatedv1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "RLS shutdown is activated"
|
||
::= 88
|
||
|
||
hzIduRlsShutdownActivatedClearedV1Trap TRAP-TYPE
|
||
ENTERPRISE hzIduTrapConfig
|
||
VARIABLES {hzIduModemAlarmsIndex}
|
||
DESCRIPTION "RLS shutdown is not activated"
|
||
::= 89
|
||
|
||
|
||
|
||
|
||
END
|