mibs/MIBS/dragonwave/MWR-ETHERNET-MIB
2023-12-05 12:25:34 +01:00

5856 lines
155 KiB
Plaintext

-- File Name : mwrEth-MIB.mib
-- Version : 1.0.0
-- Date : October 29, 2014
-- Author : DragonWave Inc.
MWR-ETHERNET-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
Unsigned32, Counter32, Counter64, IpAddress, Integer32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TruthValue, RowStatus,
DateAndTime, DisplayString
FROM SNMPv2-TC
mwr
FROM DWI-HARMONY-PRIVATE-MIB
equipmentTrapInfo, equipmentOutTrapsCounter, equipmentAlarmActiveConditionId, EnableType
FROM EQUIPMENT-COMMON-MIB
InetAddress, InetAddressType
FROM INET-ADDRESS-MIB;
mwrModIdentity MODULE-IDENTITY
LAST-UPDATED "201410081406Z"
ORGANIZATION
"Dragonwave Inc."
CONTACT-INFO
"http://www.dragonwaveinc.com
600-411 Legget Drive
Ottawa, Ontario
Canada, K2K 3C9
Tel : 613-599-9991
Fax: 613-599-4265
Support: 613-271-7010"
DESCRIPTION
"This specifies the contact information and the revision tracking information for the MIB module version."
REVISION "201410061406Z"
DESCRIPTION
"First release."
::= { mwr 1000 }
ClassType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Qos class numbers from 1 to 13."
SYNTAX INTEGER {
c1 (1),
c2 (2),
c3 (3),
c4 (4),
c5 (5),
c6 (6),
c7 (7),
c8 (8),
c9 (9),
c10 (10),
c11 (11),
c12 (12),
c13 (13)
}
--
-- Textual conventions
--
FlowType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Qos flow numbers from 1 to 13."
SYNTAX INTEGER {
flow1 (1),
flow2 (2),
flow3 (3),
flow4 (4),
flow5 (5),
flow6 (6),
flow7 (7),
flow8 (8),
flow9 (9),
flow10 (10),
flow11 (11),
flow12 (12),
flow13 (13)
}
PMIntervalType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The available interval period for statistical counters."
SYNTAX INTEGER {
quarter (1),
day (2)
}
PortType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The list of system Ethernet ports"
SYNTAX INTEGER {
gi01 (1),
gi02 (2),
gi03 (3),
gi04 (4)
}
QueueType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The queue numbers from 1 to 8 where 1 is the lowest priority queue and 8 is the highest priority queue."
SYNTAX INTEGER {
q1 (1),
q2 (2),
q3 (3),
q4 (4),
q5 (5),
q6 (6),
q7 (7),
q8 (8)
}
RadioInstanceType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The radio instance type."
SYNTAX INTEGER {
radio1 (1)
}
mwrPlatformObjId OBJECT IDENTIFIER ::= { mwr 1 }
mwrEbandObjId OBJECT IDENTIFIER ::= { mwrPlatformObjId 1 }
mwrEnhancedObjId OBJECT IDENTIFIER ::= { mwrPlatformObjId 2 }
--
-- Node definitions
--
mwrSystem OBJECT IDENTIFIER ::= { mwr 2 }
mwrSystemConfigurations OBJECT IDENTIFIER ::= { mwrSystem 1 }
mwrSysSpeed OBJECT IDENTIFIER ::= { mwrSystemConfigurations 3 }
mwrSystemStatus OBJECT IDENTIFIER ::= { mwrSystem 2 }
mwrSystemCommands OBJECT IDENTIFIER ::= { mwrSystem 3 }
mwrSystemInventory OBJECT IDENTIFIER ::= { mwrSystem 4 }
-- ----------------------------
-- mwrInventory
-- ----------------------------
mwrHwInventory OBJECT IDENTIFIER ::= { mwrSystemInventory 1 }
mwrSwInventory OBJECT IDENTIFIER ::= { mwrSystemInventory 2 }
mwrSystemNotifications OBJECT IDENTIFIER ::= { mwrSystem 5 }
mwrSoftware OBJECT IDENTIFIER ::= { mwr 3 }
mwrSoftwareConfigurations OBJECT IDENTIFIER ::= { mwrSoftware 1 }
mwrSoftwareStatus OBJECT IDENTIFIER ::= { mwrSoftware 2 }
mwrSoftwareCommands OBJECT IDENTIFIER ::= { mwrSoftware 3 }
mwrSoftwareNotifications OBJECT IDENTIFIER ::= { mwrSoftware 4 }
mwrLicensing OBJECT IDENTIFIER ::= { mwr 4 }
mwrLicensingConfigurations OBJECT IDENTIFIER ::= { mwrLicensing 1 }
mwrLicensingStatus OBJECT IDENTIFIER ::= { mwrLicensing 2 }
mwrSyncE OBJECT IDENTIFIER ::= { mwr 5 }
mwrSyncEConfigurations OBJECT IDENTIFIER ::= { mwrSyncE 1 }
mwrSyncEStatus OBJECT IDENTIFIER ::= { mwrSyncE 2 }
mwrSyncENotifications OBJECT IDENTIFIER ::= { mwrSyncE 3 }
mwrTiming OBJECT IDENTIFIER ::= { mwr 6 }
mwrTimingConfigurations OBJECT IDENTIFIER ::= { mwrTiming 1 }
mwrTimingStatus OBJECT IDENTIFIER ::= { mwrTiming 2 }
mwrTimingCommands OBJECT IDENTIFIER ::= { mwrTiming 3 }
mwrTimingNotifications OBJECT IDENTIFIER ::= { mwrTiming 4 }
mwrAAA OBJECT IDENTIFIER ::= { mwr 7 }
mwrAAAConfigurations OBJECT IDENTIFIER ::= { mwrAAA 1 }
mwrRadiusConfigurations OBJECT IDENTIFIER ::= { mwrAAAConfigurations 2 }
mwrNetworking OBJECT IDENTIFIER ::= { mwr 8 }
mwrNetworkingConfigurations OBJECT IDENTIFIER ::= { mwrNetworking 1 }
mwrNetMgmtPriority OBJECT IDENTIFIER ::= { mwrNetworkingConfigurations 1 }
mwrNetMgmtIpv4 OBJECT IDENTIFIER ::= { mwrNetworkingConfigurations 2 }
mwrNetMgmttIpv6 OBJECT IDENTIFIER ::= { mwrNetworkingConfigurations 3 }
mwrUserInterfaceMgmt OBJECT IDENTIFIER ::= { mwrNetworkingConfigurations 4 }
mwrFileTransfer OBJECT IDENTIFIER ::= { mwrNetworkingConfigurations 5 }
mwrNetworkingStatus OBJECT IDENTIFIER ::= { mwrNetworking 2 }
mwrMaintenanceIpv4 OBJECT IDENTIFIER ::= { mwrNetworkingStatus 1 }
mwrMaintenanceIpv6 OBJECT IDENTIFIER ::= { mwrNetworkingStatus 2 }
mwrPeerNetworkingStatus OBJECT IDENTIFIER ::= { mwrNetworking 3 }
mwrNetworkingNotifications OBJECT IDENTIFIER ::= { mwrNetworking 4 }
mwrEthernet OBJECT IDENTIFIER ::= { mwr 9 }
mwrEthernetConfigurations OBJECT IDENTIFIER ::= { mwrEthernet 1 }
mwrQos OBJECT IDENTIFIER ::= { mwrEthernetConfigurations 1 }
mwrEthThresholdAlarm OBJECT IDENTIFIER ::= { mwrEthernetConfigurations 2 }
mwrEthernetStatus OBJECT IDENTIFIER ::= { mwrEthernet 2 }
mwrEthernetPerformance OBJECT IDENTIFIER ::= { mwrEthernet 3 }
mwrEthernetNotifications OBJECT IDENTIFIER ::= { mwrEthernet 4 }
mwrAcm OBJECT IDENTIFIER ::= { mwr 10 }
mwrAcmConfigurations OBJECT IDENTIFIER ::= { mwrAcm 1 }
mwrAcmStatus OBJECT IDENTIFIER ::= { mwrAcm 2 }
mwrAcmDiagnostics OBJECT IDENTIFIER ::= { mwrAcm 3 }
mwrAcmNotifications OBJECT IDENTIFIER ::= { mwrAcm 4 }
mwrAtpc OBJECT IDENTIFIER ::= { mwr 11 }
mwrAtpcConfigurations OBJECT IDENTIFIER ::= { mwrAtpc 1 }
mwrAtpcStatus OBJECT IDENTIFIER ::= { mwrAtpc 2 }
mwrAtpcNotifications OBJECT IDENTIFIER ::= { mwrAtpc 3 }
mwrRadio OBJECT IDENTIFIER ::= { mwr 12 }
mwrCompression OBJECT IDENTIFIER ::= { mwr 13 }
mwrCompressionConfigurations OBJECT IDENTIFIER ::= { mwrCompression 1 }
mwrCompressionStatus OBJECT IDENTIFIER ::= { mwrCompression 2 }
mwrCompressionNotifications OBJECT IDENTIFIER ::= { mwrCompression 3 }
mwrEvents OBJECT IDENTIFIER ::= { mwr 14 }
mwrEventsConfigurations OBJECT IDENTIFIER ::= { mwrEvents 1 }
mwrLogs OBJECT IDENTIFIER ::= { mwr 15 }
mwrLogsConfigurations OBJECT IDENTIFIER ::= { mwrLogs 1 }
mwrPM OBJECT IDENTIFIER ::= { mwr 16 }
mwrPMConfigurations OBJECT IDENTIFIER ::= { mwrPM 1 }
mwrPMStatus OBJECT IDENTIFIER ::= { mwrPM 2 }
mwrPMNotifications OBJECT IDENTIFIER ::= { mwrPM 3 }
mwrUserMgmt OBJECT IDENTIFIER ::= { mwr 17 }
mwrUserConfiguration OBJECT IDENTIFIER ::= { mwrUserMgmt 1 }
mwrUserStatus OBJECT IDENTIFIER ::= { mwrUserMgmt 2 }
mwrUserNotifications OBJECT IDENTIFIER ::= { mwrUserMgmt 3 }
mwrSystemType OBJECT-TYPE
SYNTAX INTEGER {
onePlusZero1cr (1),
onePlusZero2cr (2),
onePlusZero2crXpic (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Available system types for single carrier and multi carriers systems are:
onePlusZero1cr - 1+0 single carrier
onePlusZero2cr - 1+0 dual carriers
onePlusZero2crXpic - 1+0 dual carriers XPIC"
::= { mwrSystemConfigurations 1 }
mwrPacketSwitchMode OBJECT-TYPE
SYNTAX INTEGER {
bridge (1),
port-isolation (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In bridge mode the system is always inband managed on any of the user ports. However in port-isolation mode, the system can be managed outOfBand or inband on a specific port."
::= { mwrSystemConfigurations 2 }
-- ----------------------------
-- mwrSysSpeed
-- ----------------------------
mwrSystemCurrentSpeed OBJECT-TYPE
SYNTAX Integer32 (0..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Changes the working speed of the system."
::= { mwrSysSpeed 1 }
mwrSystemOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up (1),
down (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of the system."
::= { mwrSystemStatus 1 }
mwrSystemFaultSeverity OBJECT-TYPE
SYNTAX INTEGER {
noAlarm (1),
test (2),
warning (3),
minor (4),
major (5),
critical (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the most serious system alarm severity. If system is running diagnostics, the status will be test."
::= { mwrSystemStatus 2 }
mwrSystemTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current system temperature."
::= { mwrSystemStatus 3 }
mwrPlatformType OBJECT-TYPE
SYNTAX INTEGER {
eband (1),
enhanced (2),
enhanced-mc (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the system platform type. The possible system types are:
- eband
- enhanced
- enhanced-mc"
::= { mwrSystemStatus 4 }
mwrPacketSwitchModeStatus OBJECT-TYPE
SYNTAX INTEGER {
bridge (1),
port-isolation (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the running configuration for the packet switch mode."
::= { mwrSystemStatus 5 }
mwrSystemTypeStatus OBJECT-TYPE
SYNTAX INTEGER {
onePlusZero1cr (1),
onePlusZero2cr (2),
onePlusZero2crXpic (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the running configuration for the system type status."
::= { mwrSystemStatus 6 }
-- ----------------------------
-- mwrGeneral
-- ----------------------------
mwrResetSystem OBJECT-TYPE
SYNTAX INTEGER {
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing '1' to this object resets the system."
::= { mwrSystemCommands 1 }
mwrSaveConfig OBJECT-TYPE
SYNTAX INTEGER {
save (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing '1' or 'save' to this object saves running configuration of the system."
::= { mwrSystemCommands 2 }
mwrDeleteConfig OBJECT-TYPE
SYNTAX INTEGER {
startup (1),
switch (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Using this object, either the startup config or the switch config can be deleted. Deleting startup config removes all system configuration for next system restart. Deleting switch config only clears the switch configuration."
::= { mwrSystemCommands 3 }
--
--
mwrMacAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC Address of the system."
::= { mwrHwInventory 1 }
mwrTargetCfgFilePartNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing part number of the target configuration file."
::= { mwrHwInventory 2 }
mwrUnitSerialNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing Serial Number of the Unit."
::= { mwrHwInventory 3 }
mwrUnitAssemblyNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing the Assembly Number of the Unit."
::= { mwrHwInventory 4 }
mwrBasebandSerialNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing Serial no of the baseband."
::= { mwrHwInventory 5 }
mwrBasebandAssemblyNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing assembly no of the baseband."
::= { mwrHwInventory 6 }
mwrPsuSerialNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing Serial no of the PSU."
::= { mwrHwInventory 7 }
mwrPsuAssemblyNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing assembly no of the PSU."
::= { mwrHwInventory 8 }
mwrRfSerialNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing Serial no of the RF."
::= { mwrHwInventory 9 }
mwrRfAssemblyNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing assembly no of the RF."
::= { mwrHwInventory 10 }
mwrRfRevisionNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing revision no of the RF."
::= { mwrHwInventory 11 }
mwrDiplexerSerialNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing Serial no of the Diplexer."
::= { mwrHwInventory 12 }
mwrDiplexerAssemblyNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing assembly no of the Diplexer."
::= { mwrHwInventory 13 }
mwrSystemCleiNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing system CLEI code."
::= { mwrHwInventory 14 }
-- ----------------------------
-- mwrSwInventory
-- ----------------------------
mwrSwInventoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrSwInventoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing the software inventory."
::= { mwrSwInventory 1 }
mwrSwInventoryEntry OBJECT-TYPE
SYNTAX MwrSwInventoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Software inventory entry."
INDEX { mwrSwInvBank }
::= { mwrSwInventoryTable 1 }
MwrSwInventoryEntry ::= SEQUENCE {
mwrSwInvBank
INTEGER,
mwrSwInvStatus
INTEGER,
mwrSwInvOmniRelease
DisplayString,
mwrSwInvTargetConfFileVersion
DisplayString,
mwrSwInvMibVersion
DisplayString,
mwrSwInvSecurityVersion
DisplayString
}
mwrSwInvBank OBJECT-TYPE
SYNTAX INTEGER {
bankA (1),
bankB (2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Software bank in the flash."
::= { mwrSwInventoryEntry 1 }
mwrSwInvStatus OBJECT-TYPE
SYNTAX INTEGER {
active (1),
backup (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Software bank status. "
::= { mwrSwInventoryEntry 2 }
mwrSwInvOmniRelease OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version number of the Omni."
::= { mwrSwInventoryEntry 3 }
mwrSwInvTargetConfFileVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version number of the target configuration file."
::= { mwrSwInventoryEntry 4 }
mwrSwInvMibVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version number of the system MIB."
::= { mwrSwInventoryEntry 5 }
mwrSwInvSecurityVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version number of the security package."
::= { mwrSwInventoryEntry 6 }
mwrSysTcfInvalid NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when The HW specific factory defined information (TCF) in the system is not valid."
::= { mwrSystemNotifications 1 }
mwrSysTempOutOfLimit NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when the system temperature is out of limits."
::= { mwrSystemNotifications 2 }
mwrSwBackupBankStatus OBJECT-TYPE
SYNTAX INTEGER {
notValid (1),
valid (2),
upgrading (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the status of the backup bank."
::= { mwrSoftwareStatus 1 }
mwrSwCommit OBJECT-TYPE
SYNTAX INTEGER {
commit (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing '1' to this object commits all the active bank settings to the backup bank."
::= { mwrSoftwareCommands 1 }
mwrSwSwitchBanks OBJECT-TYPE
SYNTAX INTEGER {
bankA (1),
bankB (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This objects switches bank to the specified bank. Next time the system resets, it loads up from that bank."
::= { mwrSoftwareCommands 2 }
mwrLicenseUpgradeKey OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(33))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 33 Bytes licensing key used for upgrading features/capacity. Reading this object always returns an empty string."
::= { mwrLicensingConfigurations 1 }
mwrLicenseCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of times the system has been upgraded/downgraded with features/capacity."
::= { mwrLicensingStatus 1 }
mwrLicensedSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the system licensed speed."
::= { mwrLicensingStatus 2 }
mwrLicenseFeaturesTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrLicenseFeaturesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing supported system licensed features."
::= { mwrLicensingStatus 3 }
mwrLicenseFeaturesEntry OBJECT-TYPE
SYNTAX MwrLicenseFeaturesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing supported system licensed features."
INDEX { mwrLicenseFeatureIndex }
::= { mwrLicenseFeaturesTable 1 }
MwrLicenseFeaturesEntry ::= SEQUENCE {
mwrLicenseFeatureIndex
Integer32,
mwrLicenseFeatureId
Integer32,
mwrLicenseFeature
DisplayString,
mwrLicenseFeatureStatus
INTEGER
}
mwrLicenseFeatureIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the list of system features."
::= { mwrLicenseFeaturesEntry 1 }
mwrLicenseFeatureId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"2 ACM (includes WMA where applicable) (LF2)
3 Ethernet UNI (ELINE/ELAN MEF service) (LF3)
4 Packet Fragmentation (LF4)
5 Secured Access (LF5)
6 Ethernet OAM (802.1ag, 802.3ah, Y.1731) (LF6)
7 Advanced Performance Monitoring (LF7)
11 Bandwidth Accelerator (LF11)
13 Header Compression (LF13)"
::= { mwrLicenseFeaturesEntry 2 }
mwrLicenseFeature OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the feature."
::= { mwrLicenseFeaturesEntry 3 }
mwrLicenseFeatureStatus OBJECT-TYPE
SYNTAX INTEGER {
unlicensed (1),
licensed (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether the feature is unlicensed or licensed."
::= { mwrLicenseFeaturesEntry 4 }
mwrSyncEState OBJECT-TYPE
SYNTAX INTEGER {
off (1),
manual (2),
auto (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In manual mode, SyncE source will use primary clock source and when the primary source has loss of lock, the SyncE goes into holdover. The primary source will be used again after the system regains the lock on primary source. In auto mode, if the current clock source goes out of lock, the recovered clock from the other source will be used."
::= { mwrSyncEConfigurations 1 }
mwrSyncEPrimarySource OBJECT-TYPE
SYNTAX INTEGER {
gi01 (1),
gi02 (2),
gi03 (3),
gi04 (4),
radio (5),
free-run (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects which port to be used as SyncE master clock source."
::= { mwrSyncEConfigurations 2 }
mwrSyncESecondarySource OBJECT-TYPE
SYNTAX INTEGER {
gi01 (1),
gi02 (2),
gi03 (3),
gi04 (4),
radio (5),
free-run (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects which port to be used as SyncE clock source when the master SyncE clock source is not available."
::= { mwrSyncEConfigurations 3 }
mwrSyncEMemberPorts OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enter a string indicating all SyncE member ports.
Example: gi01 gi04
Port options: gi01 gi02 gi03 gi04 radio"
::= { mwrSyncEConfigurations 4 }
mwrSyncEForcedHoldover OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This forces SyncE into holdover mode. After the configurable timeout value, the forced holdover will be taken out. The forced timeout can be 0 to 300sec, where 0 means infinite and default is 30sec.
An example of the format of the string is as follows: 'on 20' or 'off'. The second parameter indicates the holdover time in sec. The single quote marks i.e. ' ' are not used in the command."
::= { mwrSyncEConfigurations 5 }
mwrSyncERevertive OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In revertive mode, if the current source is secondary and the primary is Ok for configured amount of time, the primary will be used. The default revertive time is 10sec.
An example of the format of the string is as follows: 'on 20' or 'off'. The second parameter when revertive is turned on is the time in sec. The single quote marks i.e. ' ' are not used in the command."
::= { mwrSyncEConfigurations 6 }
mwrSyncEWanderFilter OBJECT-TYPE
SYNTAX INTEGER {
option1 (1),
option2 (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ITU G.8262 specifies different wander filter requirements for networks based on the 2.048 kbit/s hierarchy , option1, vs those based on the 1.544kbit/s hierarchy, option2. Option 2 specifies a low pass filter bandwidth of 0.1Hz, while option1 specifies a bandwidth between 1 and 10 Hz. "
::= { mwrSyncEConfigurations 7 }
mwrSyncEClockSource OBJECT-TYPE
SYNTAX INTEGER {
gi01 (1),
gi02 (2),
gi03 (3),
gi04 (4),
radio (5),
free-run (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Retrieves SyncE clock source currently in use."
::= { mwrSyncEStatus 1 }
mwrSyncEAcquisitionStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Retrieves SyncE acquisition status."
::= { mwrSyncEStatus 2 }
mwrSynceLostLock NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when system has lost synchronization to syncE clock source. "
::= { mwrSyncENotifications 1 }
mwrSynceSecondarySourceInUse NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised whens ystem has lost synchronization to primary syncE clock source, and now synchronized to secondary source."
::= { mwrSyncENotifications 2 }
mwrSynceConfigMismatch NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrEventInstanceIndex,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when the configuration of syncE between the peers in the radio link is mismatched."
::= { mwrSyncENotifications 3 }
mwrDateTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system date and time."
::= { mwrTimingConfigurations 1 }
--
-- mwrSntp
--
mwrSntpEnable OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether SNTP feature is enabled."
DEFVAL { enabled }
::= { mwrTimingConfigurations 2 }
mwrSntpOffset OBJECT-TYPE
SYNTAX Integer32 (-140..140)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System time offset from GMT in tenths of hours. For example, an offset of 10 indicates 10 tenths, or 1 hour. An offset of 5 indicates half an hour."
DEFVAL { -40 }
::= { mwrTimingConfigurations 3 }
mwrSntpServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrSntpServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing SNTP server entries"
::= { mwrTimingConfigurations 4 }
mwrSntpServerEntry OBJECT-TYPE
SYNTAX MwrSntpServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the SNTP server information"
INDEX { mwrSntpServerIndex }
::= { mwrSntpServerTable 1 }
MwrSntpServerEntry ::= SEQUENCE {
mwrSntpServerIndex
Integer32,
mwrSntpServerDomain
InetAddressType,
mwrSntpServerAddress
InetAddress,
mwrSntpServerStatus
INTEGER,
mwrSntpServerStratum
Integer32
}
mwrSntpServerIndex OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each server."
::= { mwrSntpServerEntry 1 }
mwrSntpServerDomain OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates SNTP server inet address type. Valid types are ipv4 or ipv6. "
::= { mwrSntpServerEntry 2 }
mwrSntpServerAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates SNTP server inet address octet string. "
::= { mwrSntpServerEntry 3 }
mwrSntpServerStatus OBJECT-TYPE
SYNTAX INTEGER {
good (1),
failed (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the SNTP server."
::= { mwrSntpServerEntry 4 }
mwrSntpServerStratum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the stratum of a server, 0 for failed server"
::= { mwrSntpServerEntry 5 }
mwrTimingLastDateTimeChanged OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Date and Time for the last system time adjustment."
::= { mwrTimingStatus 1 }
mwrTimingLastTimeAdjustment OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last system time adjustment in hundredths of seconds."
::= { mwrTimingStatus 2 }
mwrTimingCummulativeTimeChange OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cumulative system time adjustment in hundredths of seconds."
::= { mwrTimingStatus 3 }
mwrSntpRestoreDefault OBJECT-TYPE
SYNTAX INTEGER {
restore (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Restores SNTP servers to default Addresses."
::= { mwrTimingCommands 1 }
mwrSntpServerUnreachable NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when one or more of the configured SNTP server is not reachable by the system."
::= { mwrTimingNotifications 1 }
mwrSystemTimeCorrected NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrTimingLastDateTimeChanged,
mwrTimingLastTimeAdjustment,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised change in system time is detected, and system time is adjusted"
::= { mwrTimingNotifications 2 }
mwrAAAUserAuthentication OBJECT-TYPE
SYNTAX INTEGER {
internal (1),
radius (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the user authentication method."
::= { mwrAAAConfigurations 1 }
--
-- mwrRadius
--
mwrRadiusAdminUserStrict OBJECT-TYPE
SYNTAX INTEGER {
off (1),
on (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If strict mode is off, the admin user can login when radius is turned off or unreachable. When strict mode is on, admin user will only be authenticated against the radius server."
DEFVAL { off }
::= { mwrRadiusConfigurations 1 }
mwrRadiusServerTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Timeout period for authentication requests"
::= { mwrRadiusConfigurations 2 }
mwrRadiusServerDeadTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Time to declare an unresponsive server 'dead'"
::= { mwrRadiusConfigurations 3 }
mwrRadiusServerReTransmit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum number of retransmits to an unresponsive server"
::= { mwrRadiusConfigurations 4 }
mwrRadiusServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrRadiusServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing radius server entries"
::= { mwrRadiusConfigurations 5 }
mwrRadiusServerEntry OBJECT-TYPE
SYNTAX MwrRadiusServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the SNTP server information"
INDEX { mwrRadiusServerIndex }
::= { mwrRadiusServerTable 1 }
MwrRadiusServerEntry ::= SEQUENCE {
mwrRadiusServerIndex
Integer32,
mwrRadiusCfgdHostDomain
InetAddressType,
mwrRadiusCfgdHostAddress
InetAddress,
mwrRadiusCfgdHostKey
DisplayString
}
mwrRadiusServerIndex OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each radius server."
::= { mwrRadiusServerEntry 1 }
mwrRadiusCfgdHostDomain OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates configured radius inet address type. Valid types are ipv4 or ipv6. "
::= { mwrRadiusServerEntry 2 }
mwrRadiusCfgdHostAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates configured radius server inet address octet string."
::= { mwrRadiusServerEntry 3 }
mwrRadiusCfgdHostKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The key of the configured radius server."
::= { mwrRadiusServerEntry 4 }
mwrNetMgmtVlanPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object configures the VLAN priority(0...7)"
::= { mwrNetMgmtPriority 1 }
mwrNetMgmtDscp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Differentiated Services Code Point (DSCP) of IP traffic generated by the system (0...63)"
::= { mwrNetMgmtPriority 2 }
mwrIpv4Table OBJECT-TYPE
SYNTAX SEQUENCE OF MwrIpv4Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the IPv4 information."
::= { mwrNetMgmtIpv4 1 }
mwrIpv4Entry OBJECT-TYPE
SYNTAX MwrIpv4Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing the IPv4 information."
INDEX { mwrIpv4Index }
::= { mwrIpv4Table 1 }
MwrIpv4Entry ::= SEQUENCE {
mwrIpv4Index
Integer32,
mwrIpv4Address
IpAddress,
mwrIpv4SubnetMask
IpAddress,
mwrIpv4DefaultGateway
IpAddress,
mwrIpv4RowStatus
RowStatus
}
mwrIpv4Index OBJECT-TYPE
SYNTAX Integer32 (1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IPv4 table index. There is only one entry in this table and can not be deleted."
::= { mwrIpv4Entry 1 }
mwrIpv4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv4 address of the system."
::= { mwrIpv4Entry 2 }
mwrIpv4SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv4 subnet mask of the system."
::= { mwrIpv4Entry 3 }
mwrIpv4DefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv4 default gateway of the system."
::= { mwrIpv4Entry 4 }
mwrIpv4RowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for applying ipv4 configuration attributes simultaneously."
::= { mwrIpv4Entry 5 }
mwrSecondaryGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv4 secondary gateway of the system."
::= { mwrNetMgmtIpv4 2 }
mwrIpv6Table OBJECT-TYPE
SYNTAX SEQUENCE OF MwrIpv6Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the IPv6 information."
::= { mwrNetMgmttIpv6 1 }
mwrIpv6Entry OBJECT-TYPE
SYNTAX MwrIpv6Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing the IPv6 information."
INDEX { mwrIpv6Index }
::= { mwrIpv6Table 1 }
MwrIpv6Entry ::= SEQUENCE {
mwrIpv6Index
Integer32,
mwrIpv6Domain
InetAddressType,
mwrIpv6Address
InetAddress,
mwrIpv6Prefix
Integer32,
mwrIpv6GatewayDomain
InetAddressType,
mwrIpv6GatewayAddress
InetAddress,
mwrIpv6RowStatus
RowStatus
}
mwrIpv6Index OBJECT-TYPE
SYNTAX Integer32 (1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IPv6 table index. There is only one entry in this table and can not be deleted."
::= { mwrIpv6Entry 1 }
mwrIpv6Domain OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates ipv6 inet address type. "
::= { mwrIpv6Entry 2 }
mwrIpv6Address OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates IPv6 inet address octet string."
::= { mwrIpv6Entry 3 }
mwrIpv6Prefix OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates ipv6 prefix."
::= { mwrIpv6Entry 4 }
mwrIpv6GatewayDomain OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates IPv6 gateway inet address type. This will always return IPv6 inet address type. "
::= { mwrIpv6Entry 5 }
mwrIpv6GatewayAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates IPv6 gateway inet address octet string."
::= { mwrIpv6Entry 6 }
mwrIpv6RowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for applying IPv6 configuration attributes simultaneously."
::= { mwrIpv6Entry 7 }
mwrSecondaryIpv6GatewayDomain OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object will return the secondary IPv6 gateway inet address type."
::= { mwrNetMgmttIpv6 2 }
mwrSecondaryIpv6GatewayAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object will return the secondary IPv6 gateway inet address."
::= { mwrNetMgmttIpv6 3 }
mwrTelnetEnable OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether telnet access is allowed."
DEFVAL { enabled }
::= { mwrUserInterfaceMgmt 1 }
mwrSshEnable OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether ssh access is allowed. This configuration only applies to security mode."
::= { mwrUserInterfaceMgmt 2 }
--
-- HTTPS group
--
mwrHttpEnable OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether http is enabled."
DEFVAL { enabled }
::= { mwrUserInterfaceMgmt 3 }
mwrHttpsEnable OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether secured http access is allowed. This configuration only applies to security mode."
::= { mwrUserInterfaceMgmt 4 }
mwrSnmpv1v2cEnable OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether SNMP v1/v2c is allowed in security mode. This configuration only applies to security mode."
::= { mwrUserInterfaceMgmt 5 }
mwrFtpEnable OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows enabling or disabling ftp when in secure mode. By default ftp is enabled."
::= { mwrUserInterfaceMgmt 6 }
-- ****************************************************************
-- FTP Management configuration
-- ****************************************************************
mwrFileXfrDirection OBJECT-TYPE
SYNTAX INTEGER {
serverMode (1),
clientMode (2),
both (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The behavior of the FTP/SFTP machine:
1 - ServerMode
2 - ClientMode
3 - both Server and Client available
Mwr 1.0 just supports Client Mode.
"
DEFVAL { clientMode }
::= { mwrFileTransfer 1 }
mwrFileXfrTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrFileXfrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing the FTP client parameters."
::= { mwrFileTransfer 2 }
mwrFileXfrEntry OBJECT-TYPE
SYNTAX MwrFileXfrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry containing the FTP client parameters."
INDEX { mwrFileXfrSeqID }
::= { mwrFileXfrTable 1 }
MwrFileXfrEntry ::= SEQUENCE {
mwrFileXfrSeqID
Integer32,
mwrFileXfrIdentifier
INTEGER,
mwrFileXfrName
DisplayString,
mwrFileXfrMode
INTEGER,
mwrFileXfrServerDomain
InetAddressType,
mwrFileXfrServerAddress
InetAddress,
mwrFileXfrClientDirection
INTEGER,
mwrFileXfrUserName
DisplayString,
mwrFileXfrPassword
DisplayString,
mwrFileXfrNumEntries
Integer32,
mwrFileXfrStatus
INTEGER,
mwrFileXfrRowStatus
RowStatus
}
mwrFileXfrSeqID OBJECT-TYPE
SYNTAX Integer32 (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For the same manager, the possibility to define different FTP/SFTP transfer actions."
::= { mwrFileXfrEntry 1 }
mwrFileXfrIdentifier OBJECT-TYPE
SYNTAX INTEGER {
omni (1),
tcfFile (2),
configFile (3),
eventLog (4),
pmFile (5),
security (6),
perfLog (7)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The identifier of the type of file to be imported/exported."
::= { mwrFileXfrEntry 2 }
mwrFileXfrName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Name of the file to be imported/exported."
::= { mwrFileXfrEntry 3 }
mwrFileXfrMode OBJECT-TYPE
SYNTAX INTEGER {
ftp (1),
sftp (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The file transfer mode specifying either a ftp or sftp request. The sftp mode is only supported when security is licensed/installed."
::= { mwrFileXfrEntry 4 }
mwrFileXfrServerDomain OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The server domain such as IPv4 or IPv6 type."
::= { mwrFileXfrEntry 5 }
mwrFileXfrServerAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The server IP address in InetAddress format which could be an IPv4 or IPv6 address."
::= { mwrFileXfrEntry 6 }
mwrFileXfrClientDirection OBJECT-TYPE
SYNTAX INTEGER {
import (1),
export (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" The behavior of the FTP or SFTP Client:
1 - import, i.e. download data file
2 - export, i.e. upload data file.
The only supported option for omni and tcf is import since these files are used only in upgrade case. Also the supported option for pm, eventlog and perfLog is export option. The rest can be imported or exported."
DEFVAL { export }
::= { mwrFileXfrEntry 7 }
mwrFileXfrUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" FTP or SFTP User Name when Client Mode is selected."
::= { mwrFileXfrEntry 8 }
mwrFileXfrPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" FTP or SFTP password when Client Mode is selected. For get operation - the returned value will be zero length string.
"
::= { mwrFileXfrEntry 9 }
mwrFileXfrNumEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to indicate the number of entries for the performance log to be transferred. If it's set to zero, it will transfer the entire file."
::= { mwrFileXfrEntry 10 }
mwrFileXfrStatus OBJECT-TYPE
SYNTAX INTEGER {
success (1),
inProgress (2),
failed (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the current status of the last requested import/export of the corresponding row component."
::= { mwrFileXfrEntry 11 }
mwrFileXfrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable, used according to:
- Manager can create a row using the createAndWait.
- Once created, the row is put into notInService by Agent.
- On Manager request, row status can be set to active one at a time. This means that the Client has
to start the file transfer.
- Row data, such as the FileServerAddress, User Name or Password
can be changed once the row has been created, but only if this field
is set to notInService. All other fields can not be set once the row
is created, but the row must be removed and created again.
- Manager can use destroy to remove the row.
"
::= { mwrFileXfrEntry 12 }
mwrNetMgmtInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrNetMgmtInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing the network management interface configurations."
::= { mwrNetworkingConfigurations 6 }
mwrNetMgmtInterfaceEntry OBJECT-TYPE
SYNTAX MwrNetMgmtInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry for the network management interface table."
INDEX { mwrNetMgmtInterfaceIndex }
::= { mwrNetMgmtInterfaceTable 1 }
MwrNetMgmtInterfaceEntry ::= SEQUENCE {
mwrNetMgmtInterfaceIndex
Integer32,
mwrNetMgmtVlanId
Integer32,
mwrNetMgmtInterface1
EnableType,
mwrNetMgmtInterface1Mode
INTEGER,
mwrNetMgmtInterface1Tagged
INTEGER,
mwrNetMgmtInterface2
EnableType,
mwrNetMgmtInterface2Mode
INTEGER,
mwrNetMgmtInterface2Tagged
INTEGER,
mwrNetMgmtInterface3
EnableType,
mwrNetMgmtInterface3Mode
INTEGER,
mwrNetMgmtInterface3Tagged
INTEGER,
mwrNetMgmtInterface4
EnableType,
mwrNetMgmtInterface4Mode
INTEGER,
mwrNetMgmtInterface4Tagged
INTEGER,
mwrNetMgmtInterfaceRowStatus
RowStatus
}
mwrNetMgmtInterfaceIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an index to network management interface table. There will always be one entry in this table."
::= { mwrNetMgmtInterfaceEntry 1 }
mwrNetMgmtVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4090)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the VLAN Id (1...4090)"
::= { mwrNetMgmtInterfaceEntry 2 }
mwrNetMgmtInterface1 OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is enabled the gi0/1 port will be configured as a management port. Also the corresponding mode (inband/outOfBand) should be set as well."
::= { mwrNetMgmtInterfaceEntry 3 }
mwrNetMgmtInterface1Mode OBJECT-TYPE
SYNTAX INTEGER {
inband (1),
outOfBand (2),
none (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the gi0/1 management interface is inband or outOfBand. This applies only when the packet switch mode is configured in port isolation mode. In Bridge mode setup, this will always be inband."
::= { mwrNetMgmtInterfaceEntry 4 }
mwrNetMgmtInterface1Tagged OBJECT-TYPE
SYNTAX INTEGER {
no-vlan-tag (1),
vlan-tag (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the system will be managed with vlan tagged management traffic or not."
::= { mwrNetMgmtInterfaceEntry 5 }
mwrNetMgmtInterface2 OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is enabled the gi0/2 port will be configured as a management port. Also the corresponding mode (inband/outOfBand) should be set as well."
::= { mwrNetMgmtInterfaceEntry 6 }
mwrNetMgmtInterface2Mode OBJECT-TYPE
SYNTAX INTEGER {
inband (1),
outOfBand (2),
none (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the gi0/2 management interface is inband or outOfBand. This applies only when the packet switch mode is configured in port isolation mode. In Bridge mode setup, this will always be inband."
::= { mwrNetMgmtInterfaceEntry 7 }
mwrNetMgmtInterface2Tagged OBJECT-TYPE
SYNTAX INTEGER {
no-vlan-tag (1),
vlan-tag (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the system will be managed with vlan tagged management traffic or not."
::= { mwrNetMgmtInterfaceEntry 8 }
mwrNetMgmtInterface3 OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is enabled the gi0/3 port will be configured as a management port. Also the corresponding mode (inband/outOfBand) should be set as well."
::= { mwrNetMgmtInterfaceEntry 9 }
mwrNetMgmtInterface3Mode OBJECT-TYPE
SYNTAX INTEGER {
inband (1),
outOfBand (2),
none (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the gi0/3 management interface is inband or outOfBand. This applies only when the packet switch mode is configured in port isolation mode. In Bridge mode setup, this will always be inband."
::= { mwrNetMgmtInterfaceEntry 10 }
mwrNetMgmtInterface3Tagged OBJECT-TYPE
SYNTAX INTEGER {
no-vlan-tag (1),
vlan-tag (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the system will be managed with vlan tagged management traffic or not."
::= { mwrNetMgmtInterfaceEntry 11 }
mwrNetMgmtInterface4 OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is enabled the gi0/4 port will be configured as a management port. Also the corresponding mode (inband/outOfBand) should be set as well."
::= { mwrNetMgmtInterfaceEntry 12 }
mwrNetMgmtInterface4Mode OBJECT-TYPE
SYNTAX INTEGER {
inband (1),
outOfBand (2),
none (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the gi0/4 management interface is inband or outOfBand. This applies only when the packet switch mode is configured in port isolation mode. In Bridge mode setup, this will always be inband."
::= { mwrNetMgmtInterfaceEntry 13 }
mwrNetMgmtInterface4Tagged OBJECT-TYPE
SYNTAX INTEGER {
no-vlan-tag (1),
vlan-tag (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the system will be managed with vlan tagged management traffic or not."
::= { mwrNetMgmtInterfaceEntry 14 }
mwrNetMgmtInterfaceRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for applying all management interface configuration in an atomic operation."
::= { mwrNetMgmtInterfaceEntry 15 }
mwrMaintenanceIpv4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the maintenance IPv4 address."
::= { mwrMaintenanceIpv4 1 }
mwrMaintenanceSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the maintenance IPv4 subnet mask."
::= { mwrMaintenanceIpv4 2 }
mwrActiveIpv4Gateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the active IPv4 gateway."
::= { mwrMaintenanceIpv4 3 }
mwrIpv6LinkLocalIPrefix OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the IPv6 link local prefix."
::= { mwrMaintenanceIpv6 1 }
mwrIpv6LinkLocalAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates ipv6 link local inet address octet string."
::= { mwrMaintenanceIpv6 2 }
mwrActiveIpv6Gateway OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the active IPv6 gateway."
::= { mwrMaintenanceIpv6 3 }
-- ----------------------
-- mwrPeerSysInfo
-- ---------------------
mwrPeerMacAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC Address of the peer."
::= { mwrPeerNetworkingStatus 1 }
mwrPeerIpv4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peer IPv4 Address."
::= { mwrPeerNetworkingStatus 2 }
mwrPeerIpv4SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peer IPv4 subnet mask."
::= { mwrPeerNetworkingStatus 3 }
mwrPeerIpv4DefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peer IPv4 default gateway."
::= { mwrPeerNetworkingStatus 4 }
mwrPeerIpv6Prefix OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peer IPv6 prefix."
::= { mwrPeerNetworkingStatus 5 }
mwrPeerIpv6Domain OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peer IPv6 domain."
::= { mwrPeerNetworkingStatus 6 }
mwrPeerIpv6Address OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peer IPv6 address."
::= { mwrPeerNetworkingStatus 7 }
mwrPeerIpv6GatewayDomain OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peer IPv6 gateway domain"
::= { mwrPeerNetworkingStatus 8 }
mwrPeerIpv6GatewayAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peer IPv6 gateway address."
::= { mwrPeerNetworkingStatus 9 }
mwrPeerVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peer vlan Id."
::= { mwrPeerNetworkingStatus 10 }
mwrPeerVlanPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peer vlan priority."
::= { mwrPeerNetworkingStatus 11 }
mwrPeerDscp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The peer management dscp."
::= { mwrPeerNetworkingStatus 12 }
--
-- Qos
--
mwrQosState OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether QOS is enabled."
DEFVAL { disabled }
::= { mwrQos 1 }
mwrCosSource OBJECT-TYPE
SYNTAX INTEGER {
oTag (1),
iTag (2),
dscp (3),
mplsExp (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the class of service tag type. Based on the setting system will use the CoS value in the outer VLAN tag, inner VLAN tag, DSCP or MPLS exp."
::= { mwrQos 2 }
mwrOuterTpid OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the value of the Q-in-Q outer tag. This tag is also used to classify the single tagged traffic. Default value is 0x8100."
::= { mwrQos 3 }
mwrInnerTpid OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the value of the Q-in-Q inner VLAN tag. Default value is 0x8100."
::= { mwrQos 4 }
mwrCosTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrCosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Qos Settings per port, the configuration corresponds to the egress QoS of radio port."
::= { mwrQos 5 }
mwrCosEntry OBJECT-TYPE
SYNTAX MwrCosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of Qos setting per port"
INDEX { mwrCosIndex }
::= { mwrCosTable 1 }
MwrCosEntry ::= SEQUENCE {
mwrCosIndex
INTEGER,
mwrCos0
QueueType,
mwrCos1
QueueType,
mwrCos2
QueueType,
mwrCos3
QueueType,
mwrCos4
QueueType,
mwrCos5
QueueType,
mwrCos6
QueueType,
mwrCos7
QueueType,
mwrCosRowStatus
RowStatus
}
mwrCosIndex OBJECT-TYPE
SYNTAX INTEGER {
gi01 (1),
gi02 (2),
gi03 (3),
gi04 (4),
bridgeMode (5)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique name identifying each enet port in port isolation mode or the bridgeMode index when system is configured in bridge mode."
::= { mwrCosEntry 1 }
mwrCos0 OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue assignments for CoS0. There are 8 CoS queues. Their corresponding queue numbers are 1 to 8 where 1 is the lowest priority queue and 8 is the highest priority queue."
::= { mwrCosEntry 2 }
mwrCos1 OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue assignments for CoS1. There are 8 CoS queues. Their corresponding queue numbers are 1 to 8 where 1 is the lowest priority queue and 8 is the highest priority queue."
::= { mwrCosEntry 3 }
mwrCos2 OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue assignments for CoS2. There are 8 CoS queues. Their corresponding queue numbers are 1 to 8 where 1 is the lowest priority queue and 8 is the highest priority queue."
::= { mwrCosEntry 4 }
mwrCos3 OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue assignments for CoS3. There are 8 CoS queues. Their corresponding queue numbers are 1 to 8 where 1 is the lowest priority queue and 8 is the highest priority queue."
::= { mwrCosEntry 5 }
mwrCos4 OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue assignments for CoS4. There are 8 CoS queues. Their corresponding queue numbers are 1 to 8 where 1 is the lowest priority queue and 8 is the highest priority queue."
::= { mwrCosEntry 6 }
mwrCos5 OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue assignments for CoS5. There are 8 CoS queues. Their corresponding queue numbers are 1 to 8 where 1 is the lowest priority queue and 8 is the highest priority queue."
::= { mwrCosEntry 7 }
mwrCos6 OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue assignments for CoS6. There are 8 CoS queues. Their corresponding queue numbers are 1 to 8 where 1 is the lowest priority queue and 8 is the highest priority queue."
::= { mwrCosEntry 8 }
mwrCos7 OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue assignments for CoS7. There are 8 CoS queues. Their corresponding queue numbers are 1 to 8 where 1 is the lowest priority queue and 8 is the highest priority queue."
::= { mwrCosEntry 9 }
mwrCosRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Row status for CoS queue mapping. This object is used to apply all CoS settings simultaneously."
::= { mwrCosEntry 10 }
mwrCosDefValueTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrCosDefValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the CoS default value, the configuration corresponds to the egress QoS of radio port."
::= { mwrQos 6 }
mwrCosDefValueEntry OBJECT-TYPE
SYNTAX MwrCosDefValueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing the CoS default value."
INDEX { mwrCosDefValueIndex }
::= { mwrCosDefValueTable 1 }
MwrCosDefValueEntry ::= SEQUENCE {
mwrCosDefValueIndex
INTEGER,
mwrCosDefValue
Integer32
}
mwrCosDefValueIndex OBJECT-TYPE
SYNTAX INTEGER {
gi01 (1),
gi02 (2),
gi03 (3),
gi04 (4),
bridgeMode (5)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies CoS default value for each port in port isolation or in bridge mode."
::= { mwrCosDefValueEntry 1 }
mwrCosDefValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies CoS default value for each port in port isolation or in bridge mode."
::= { mwrCosDefValueEntry 2 }
mwrCirQTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrCirQEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the CIR value for each queue, the configuration corresponds to the egress QoS of radio port."
::= { mwrQos 7 }
mwrCirQEntry OBJECT-TYPE
SYNTAX MwrCirQEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing the CIR value for each radio queue."
INDEX { mwrCirQIndex }
::= { mwrCirQTable 1 }
MwrCirQEntry ::= SEQUENCE {
mwrCirQIndex
QueueType,
mwrCirQ1
Integer32,
mwrCirQ2
Integer32,
mwrCirQ3
Integer32,
mwrCirQ4
Integer32,
mwrCirQ5
Integer32,
mwrCirQ6
Integer32,
mwrCirQ7
Integer32,
mwrCirQ8
Integer32,
mwrCirQRowStatus
RowStatus
}
mwrCirQIndex OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies CIR queue index for each radio queue."
::= { mwrCirQEntry 1 }
mwrCirQ1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CIR setting for queue 1."
::= { mwrCirQEntry 2 }
mwrCirQ2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CIR setting for queue 2."
::= { mwrCirQEntry 3 }
mwrCirQ3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CIR setting for queue 3."
::= { mwrCirQEntry 4 }
mwrCirQ4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CIR setting for queue 4."
::= { mwrCirQEntry 5 }
mwrCirQ5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CIR setting for queue 5."
::= { mwrCirQEntry 6 }
mwrCirQ6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CIR setting for queue 6."
::= { mwrCirQEntry 7 }
mwrCirQ7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CIR setting for queue 7."
::= { mwrCirQEntry 8 }
mwrCirQ8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CIR setting for queue 8."
::= { mwrCirQEntry 9 }
mwrCirQRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The CIR table Row status. This object is used to apply all queue CIR settings simultaneously."
::= { mwrCirQEntry 10 }
mwrCbsQTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrCbsQEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing CBS settings for each queue, the configuration corresponds to the egress QoS of radio port."
::= { mwrQos 8 }
mwrCbsQEntry OBJECT-TYPE
SYNTAX MwrCbsQEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing CBS settings for each queue."
INDEX { mwrCbsQIndex }
::= { mwrCbsQTable 1 }
MwrCbsQEntry ::= SEQUENCE {
mwrCbsQIndex
QueueType,
mwrCbsQ1
Integer32,
mwrCbsQ2
Integer32,
mwrCbsQ3
Integer32,
mwrCbsQ4
Integer32,
mwrCbsQ5
Integer32,
mwrCbsQ6
Integer32,
mwrCbsQ7
Integer32,
mwrCbsQ8
Integer32,
mwrCbsQRowStatus
RowStatus
}
mwrCbsQIndex OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies CBS queue index for each radio queue."
::= { mwrCbsQEntry 1 }
mwrCbsQ1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CBS setting for queue 1."
::= { mwrCbsQEntry 2 }
mwrCbsQ2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CBS setting for queue 2."
::= { mwrCbsQEntry 3 }
mwrCbsQ3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CBS setting for queue 3."
::= { mwrCbsQEntry 4 }
mwrCbsQ4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CBS setting for queue 4."
::= { mwrCbsQEntry 5 }
mwrCbsQ5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CBS setting for queue 5."
::= { mwrCbsQEntry 6 }
mwrCbsQ6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CBS setting for queue 6."
::= { mwrCbsQEntry 7 }
mwrCbsQ7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CBS setting for queue 7."
::= { mwrCbsQEntry 8 }
mwrCbsQ8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User CBS setting for queue 8."
::= { mwrCbsQEntry 9 }
mwrCbsQRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The CBS table Row status. This object is used to apply all queue CBS settings simultaneously."
::= { mwrCbsQEntry 10 }
mwrWeightQTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrWeightQEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing queue weight setting for each queue, the configuration corresponds to the egress QoS of radio port."
::= { mwrQos 9 }
mwrWeightQEntry OBJECT-TYPE
SYNTAX MwrWeightQEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing queue weight setting for each queue."
INDEX { mwrWeightQIndex }
::= { mwrWeightQTable 1 }
MwrWeightQEntry ::= SEQUENCE {
mwrWeightQIndex
QueueType,
mwrWeightQ1
Integer32,
mwrWeightQ2
Integer32,
mwrWeightQ3
Integer32,
mwrWeightQ4
Integer32,
mwrWeightQ5
Integer32,
mwrWeightQ6
Integer32,
mwrWeightQ7
Integer32,
mwrWeightQ8
Integer32,
mwrWeightQRowStatus
RowStatus
}
mwrWeightQIndex OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies queue weight index for each radio queue."
::= { mwrWeightQEntry 1 }
mwrWeightQ1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue weight value for queue 1."
::= { mwrWeightQEntry 2 }
mwrWeightQ2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue weight value for queue 2."
::= { mwrWeightQEntry 3 }
mwrWeightQ3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue weight value for queue 3."
::= { mwrWeightQEntry 4 }
mwrWeightQ4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue weight value for queue 4."
::= { mwrWeightQEntry 5 }
mwrWeightQ5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue weight value for queue 5."
::= { mwrWeightQEntry 6 }
mwrWeightQ6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue weight value for queue 6."
::= { mwrWeightQEntry 7 }
mwrWeightQ7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue weight value for queue 7."
::= { mwrWeightQEntry 8 }
mwrWeightQ8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue weight value for queue 8."
::= { mwrWeightQEntry 9 }
mwrWeightQRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The queue weight table Row status. This object is used to apply all queue weight settings simultaneously."
::= { mwrWeightQEntry 10 }
mwrQbsQTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrQbsQEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing queue buffer size, the configuration corresponds to the egress QoS of radio port."
::= { mwrQos 10 }
mwrQbsQEntry OBJECT-TYPE
SYNTAX MwrQbsQEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing queue buffer size."
INDEX { mwrQbsQIndex }
::= { mwrQbsQTable 1 }
MwrQbsQEntry ::= SEQUENCE {
mwrQbsQIndex
QueueType,
mwrQbsQ1
Integer32,
mwrQbsQ2
Integer32,
mwrQbsQ3
Integer32,
mwrQbsQ4
Integer32,
mwrQbsQ5
Integer32,
mwrQbsQ6
Integer32,
mwrQbsQ7
Integer32,
mwrQbsQ8
Integer32,
mwrQbsQRowStatus
RowStatus
}
mwrQbsQIndex OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies QBS queue index for each radio queue."
::= { mwrQbsQEntry 1 }
mwrQbsQ1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue buffer size (QBS) for queue 1."
::= { mwrQbsQEntry 2 }
mwrQbsQ2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue buffer size (QBS) for queue 2."
::= { mwrQbsQEntry 3 }
mwrQbsQ3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue buffer size (QBS) for queue 3."
::= { mwrQbsQEntry 4 }
mwrQbsQ4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue buffer size (QBS) for queue 4."
::= { mwrQbsQEntry 5 }
mwrQbsQ5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue buffer size (QBS) for queue 5."
::= { mwrQbsQEntry 6 }
mwrQbsQ6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue buffer size (QBS) for queue 6."
::= { mwrQbsQEntry 7 }
mwrQbsQ7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue buffer size (QBS) for queue 7."
::= { mwrQbsQEntry 8 }
mwrQbsQ8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies queue buffer size (QBS) for queue 8."
::= { mwrQbsQEntry 9 }
mwrQbsQRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The queue buffer size (QBS) table Row status. This object is used to apply all queue QBS settings simultaneously."
::= { mwrQbsQEntry 10 }
mwrPolicyQTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrPolicyQEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing queue policy for each queue, the configuration corresponds to the egress QoS of radio port."
::= { mwrQos 11 }
mwrPolicyQEntry OBJECT-TYPE
SYNTAX MwrPolicyQEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing queue policy for each queue."
INDEX { mwrPolicyQIndex }
::= { mwrPolicyQTable 1 }
MwrPolicyQEntry ::= SEQUENCE {
mwrPolicyQIndex
QueueType,
mwrPolicyQ1
INTEGER,
mwrPolicyQ2
INTEGER,
mwrPolicyQ3
INTEGER,
mwrPolicyQ4
INTEGER,
mwrPolicyQ5
INTEGER,
mwrPolicyQ6
INTEGER,
mwrPolicyQ7
INTEGER,
mwrPolicyQ8
INTEGER,
mwrPolicyQRowStatus
RowStatus
}
mwrPolicyQIndex OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies queue policy index for each radio queue."
::= { mwrPolicyQEntry 1 }
mwrPolicyQ1 OBJECT-TYPE
SYNTAX INTEGER {
wfq (1),
priority (2),
pf (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue policy value for queue 1."
::= { mwrPolicyQEntry 2 }
mwrPolicyQ2 OBJECT-TYPE
SYNTAX INTEGER {
wfq (1),
priority (2),
pf (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue policy value for queue 2."
::= { mwrPolicyQEntry 3 }
mwrPolicyQ3 OBJECT-TYPE
SYNTAX INTEGER {
wfq (1),
priority (2),
pf (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue policy value for queue 3."
::= { mwrPolicyQEntry 4 }
mwrPolicyQ4 OBJECT-TYPE
SYNTAX INTEGER {
wfq (1),
priority (2),
pf (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue policy value for queue 4."
::= { mwrPolicyQEntry 5 }
mwrPolicyQ5 OBJECT-TYPE
SYNTAX INTEGER {
wfq (1),
priority (2),
pf (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue policy value for queue 5."
::= { mwrPolicyQEntry 6 }
mwrPolicyQ6 OBJECT-TYPE
SYNTAX INTEGER {
wfq (1),
priority (2),
pf (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue policy value for queue 6."
::= { mwrPolicyQEntry 7 }
mwrPolicyQ7 OBJECT-TYPE
SYNTAX INTEGER {
wfq (1),
priority (2),
pf (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue policy value for queue 7."
::= { mwrPolicyQEntry 8 }
mwrPolicyQ8 OBJECT-TYPE
SYNTAX INTEGER {
wfq (1),
priority (2),
pf (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User queue policy value for queue 8."
::= { mwrPolicyQEntry 9 }
mwrPolicyQRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The queue policy table Row status. This object is used to apply all queue policy settings simultaneously."
::= { mwrPolicyQEntry 10 }
mwrUserClassTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrUserClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing QOS user class settings, the configuration corresponds to the egress QoS of radio port."
::= { mwrQos 12 }
mwrUserClassEntry OBJECT-TYPE
SYNTAX MwrUserClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing QOS user class settings."
INDEX { mwrUserClassIndex }
::= { mwrUserClassTable 1 }
MwrUserClassEntry ::= SEQUENCE {
mwrUserClassIndex
ClassType,
mwrUserClassOffset
Integer32,
mwrUserClassValue
DisplayString,
mwrUserClassMask
DisplayString
}
mwrUserClassIndex OBJECT-TYPE
SYNTAX ClassType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies user class queue index for each radio queue."
::= { mwrUserClassEntry 1 }
mwrUserClassOffset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies user class offset value."
::= { mwrUserClassEntry 2 }
mwrUserClassValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies user class value."
::= { mwrUserClassEntry 3 }
mwrUserClassMask OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies user class mask."
::= { mwrUserClassEntry 4 }
mwrUserFlowTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrUserFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing QOS user flow settings, the configuration corresponds to the egress QoS of radio port."
::= { mwrQos 13 }
mwrUserFlowEntry OBJECT-TYPE
SYNTAX MwrUserFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing QOS user flow settings."
INDEX { mwrUserFlowIndex }
::= { mwrUserFlowTable 1 }
MwrUserFlowEntry ::= SEQUENCE {
mwrUserFlowIndex
FlowType,
mwrUserFlowFilter
DisplayString
}
mwrUserFlowIndex OBJECT-TYPE
SYNTAX FlowType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies user flow filter queue index for each queue."
::= { mwrUserFlowEntry 1 }
mwrUserFlowFilter OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies user flow filter value for each queue."
::= { mwrUserFlowEntry 2 }
mwrUserFlowMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrUserFlowMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing QOS user flow mapping settings in port isolation mode."
::= { mwrQos 14 }
mwrUserFlowMappingEntry OBJECT-TYPE
SYNTAX MwrUserFlowMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing QOS user flow mapping settings in port isolation mode."
INDEX { mwrUserFlowMappingIndex }
::= { mwrUserFlowMappingTable 1 }
MwrUserFlowMappingEntry ::= SEQUENCE {
mwrUserFlowMappingIndex
FlowType,
mwrUserFlowMappingState
EnableType,
mwrUserFlowMapping1Q
QueueType,
mwrUserFlowMapping2Q
QueueType,
mwrUserFlowMapping3Q
QueueType,
mwrUserFlowMapping4Q
QueueType,
mwrUserFlowMappingRowStatus
RowStatus
}
mwrUserFlowMappingIndex OBJECT-TYPE
SYNTAX FlowType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies user flow mapping index for each flow in port isolation mode."
::= { mwrUserFlowMappingEntry 1 }
mwrUserFlowMappingState OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disabled user flow mapping for a specific flow in port isolation mode."
::= { mwrUserFlowMappingEntry 2 }
mwrUserFlowMapping1Q OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the selected queue for gi01 in port isolation mode."
::= { mwrUserFlowMappingEntry 3 }
mwrUserFlowMapping2Q OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the selected queue for gi02 in port isolation mode."
::= { mwrUserFlowMappingEntry 4 }
mwrUserFlowMapping3Q OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the selected queue for gi03 in port isolation mode."
::= { mwrUserFlowMappingEntry 5 }
mwrUserFlowMapping4Q OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the selected queue for gi04 in port isolation mode."
::= { mwrUserFlowMappingEntry 6 }
mwrUserFlowMappingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Row status for user flow mapping in port isolation mode."
::= { mwrUserFlowMappingEntry 7 }
mwrUserFlowMappingBridgeModeTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrUserFlowMappingBridgeModeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing QOS user flow mapping settings in bridge mode, the configuration corresponds to the egress QoS of radio port."
::= { mwrQos 15 }
mwrUserFlowMappingBridgeModeEntry OBJECT-TYPE
SYNTAX MwrUserFlowMappingBridgeModeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing QOS user flow mapping settings in bridge mode."
INDEX { mwrUserFlowMappingBridgeModeIndex }
::= { mwrUserFlowMappingBridgeModeTable 1 }
MwrUserFlowMappingBridgeModeEntry ::= SEQUENCE {
mwrUserFlowMappingBridgeModeIndex
FlowType,
mwrUserFlowMappingBridgeModeState
EnableType,
mwrUserFlowMappingBridgeModeQ
QueueType,
mwrUserFlowMappingBridgeModeRowStatus
RowStatus
}
mwrUserFlowMappingBridgeModeIndex OBJECT-TYPE
SYNTAX FlowType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies user flow mapping index for each flow in bridge mode."
::= { mwrUserFlowMappingBridgeModeEntry 1 }
mwrUserFlowMappingBridgeModeState OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disabled user flow mapping for a specific flow in bridge mode."
::= { mwrUserFlowMappingBridgeModeEntry 2 }
mwrUserFlowMappingBridgeModeQ OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the selected user flow mapping queue in bridge mode."
::= { mwrUserFlowMappingBridgeModeEntry 3 }
mwrUserFlowMappingBridgeModeRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Row status for user flow mapping in bridge mode."
::= { mwrUserFlowMappingBridgeModeEntry 4 }
mwrPortThresholdAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrPortThresholdAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing threshold alarms parameters."
::= { mwrEthThresholdAlarm 1 }
mwrPortThresholdAlarmEntry OBJECT-TYPE
SYNTAX MwrPortThresholdAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing threshold alarms parameters."
INDEX { mwrPortThresholdAlarmIndex }
::= { mwrPortThresholdAlarmTable 1 }
MwrPortThresholdAlarmEntry ::= SEQUENCE {
mwrPortThresholdAlarmIndex
Integer32,
mwrDroppedPktsThresholdParams
DisplayString,
mwrOutBWUtilizationThresholdParams
DisplayString,
mwrThroughputThresholdParams
DisplayString
}
mwrPortThresholdAlarmIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index to Threshold alarm table. Instance 1 indicates Radio port."
::= { mwrPortThresholdAlarmEntry 1 }
mwrDroppedPktsThresholdParams OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..24))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the dropped packets threshold settings. The threshold, in percent and the number of seconds that it must exceed this threshold. An example of the format of the string is as follows: '70 10'. The first parameter is the percentage of packets that are dropped, the second is the time in seconds that the threshold must be exceeded. The single quote marks i.e. ' ' are not used in the command."
::= { mwrPortThresholdAlarmEntry 2 }
mwrOutBWUtilizationThresholdParams OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the BW utilization threshold settings. The threshold, in percent and the number of seconds that it must exceed this threshold. An example of the format of the string is as follows: '70 10'. The first parameter is the percentage of BW threshold, the second is the time in seconds that the threshold must be exceeded. The single quote marks i.e. ' ' are not used in the command"
::= { mwrPortThresholdAlarmEntry 3 }
mwrThroughputThresholdParams OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the radio throughput threshold settings. The threshold, in percent and the number of seconds that it must exceed this threshold. An example of the format of the string is as follows: '70 10'. The first parameter is the percentage of the throughput, the second is the time in seconds that the threshold must be exceeded. The single quote marks i.e. ' ' are not used in the command"
::= { mwrPortThresholdAlarmEntry 4 }
mwrRadioQThresholdAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrRadioQThresholdAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of radio port queue based Threshold Alarm settings, the configuration corresponds to the egress QoS of radio port."
::= { mwrEthThresholdAlarm 2 }
mwrRadioQThresholdAlarmEntry OBJECT-TYPE
SYNTAX MwrRadioQThresholdAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry of queue based Threshold Alarm settings."
INDEX { mwrRadioQThresholdAlarmIndex }
::= { mwrRadioQThresholdAlarmTable 1 }
MwrRadioQThresholdAlarmEntry ::= SEQUENCE {
mwrRadioQThresholdAlarmIndex
QueueType,
mwrRadioQDepthThresholdParams
DisplayString,
mwrRadioQDroppedPktsThresholdParams
DisplayString
}
mwrRadioQThresholdAlarmIndex OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier for one of the 8 queues"
::= { mwrRadioQThresholdAlarmEntry 1 }
mwrRadioQDepthThresholdParams OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold, in percent, and the number of seconds that it must exceed this threshold are programmed by the user. An example of the format of the string is as follows: '70 10'. The first parameter is the percentage of queue depth, the second is the time in seconds that the threshold must be exceeded."
::= { mwrRadioQThresholdAlarmEntry 2 }
mwrRadioQDroppedPktsThresholdParams OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold, in packets, and the number of seconds that it must exceed this threshold are programmed by the user. An example of the format of the string is as follows: '70 10'. The first parameter is the number of packets that are dropped, the second is the time in seconds that the threshold must be exceeded."
::= { mwrRadioQThresholdAlarmEntry 3 }
mwrEnetPerfPortStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrEnetPerfPortStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing Ethernet port statistics."
::= { mwrEthernetPerformance 1 }
mwrEnetPerfPortStatsEntry OBJECT-TYPE
SYNTAX MwrEnetPerfPortStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing Ethernet port statistics."
INDEX { mwrEnetPortStatsIndex }
::= { mwrEnetPerfPortStatsTable 1 }
MwrEnetPerfPortStatsEntry ::= SEQUENCE {
mwrEnetPortStatsIndex
INTEGER,
mwrPortStatsInOctet
Counter64,
mwrPortStatsInGoodPkts
Counter64,
mwrPortStatsInErrPkts
Counter64,
mwrPortStatsInDiscardPkts
Counter64,
mwrPortStatsOutOctets
Counter64,
mwrPortStatsOutGoodPkts
Counter64,
mwrPortStatsOutErrPkts
Counter64,
mwrPortStatsOutDiscardPkts
Counter64,
mwrPortStatsOutBwUtilization
Integer32,
mwrPortStatsInBwUtilization
Integer32,
mwrPortStatsInDataRate
Integer32,
mwrPortStatsThroughput
Integer32
}
mwrEnetPortStatsIndex OBJECT-TYPE
SYNTAX INTEGER {
gi01 (1),
gi02 (2),
gi03 (3),
gi04 (4),
radio (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A table index to Ethernet ports."
::= { mwrEnetPerfPortStatsEntry 1 }
mwrPortStatsInOctet OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 64-bit counter representing the incoming octets."
::= { mwrEnetPerfPortStatsEntry 2 }
mwrPortStatsInGoodPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 64-bit counter representing the incoming good packets."
::= { mwrEnetPerfPortStatsEntry 3 }
mwrPortStatsInErrPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 64-bit counter representing the incoming error packets."
::= { mwrEnetPerfPortStatsEntry 4 }
mwrPortStatsInDiscardPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 64-bit counter representing the incoming discarded packets."
::= { mwrEnetPerfPortStatsEntry 5 }
mwrPortStatsOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 64-bit counter representing the outgoing octets."
::= { mwrEnetPerfPortStatsEntry 6 }
mwrPortStatsOutGoodPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 64-bit counter representing the outgoing good packets."
::= { mwrEnetPerfPortStatsEntry 7 }
mwrPortStatsOutErrPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 64-bit counter representing the outgoing error packets."
::= { mwrEnetPerfPortStatsEntry 8 }
mwrPortStatsOutDiscardPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 64-bit counter representing the outgoing discarded packets."
::= { mwrEnetPerfPortStatsEntry 9 }
mwrPortStatsOutBwUtilization OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the ratio of egress data rate and the egress link capacity of the port. The value is represented in %."
::= { mwrEnetPerfPortStatsEntry 10 }
mwrPortStatsInBwUtilization OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the ratio of ingress data rate and the ingress link capacity of the port. The value is represented in %."
::= { mwrEnetPerfPortStatsEntry 11 }
mwrPortStatsInDataRate OBJECT-TYPE
SYNTAX Integer32
UNITS "Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Ethernet data rate coming into the port. The data rate is multiplied by 100. e.g. A display of 1530 is actually 15.30 Mpbs"
::= { mwrEnetPerfPortStatsEntry 12 }
mwrPortStatsThroughput OBJECT-TYPE
SYNTAX Integer32
UNITS "Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Ethernet data rate going out of the port. The data rate is multiplied by 100. e.g. A display of 1530 is actually 15.30 Mpbs."
::= { mwrEnetPerfPortStatsEntry 13 }
mwrEnetPerfPortStats32BitTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrEnetPerfPortStats32BitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing 32-bit Ethernet statistics. This table is provided to satisfy snmp v1 users where they can't access 64-bit counters."
::= { mwrEthernetPerformance 2 }
mwrEnetPerfPortStats32BitEntry OBJECT-TYPE
SYNTAX MwrEnetPerfPortStats32BitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing 32-bit Ethernet statistics. This table is provided to satisfy snmp v1 users where they can't access 64-bit counters."
INDEX { mwrPortStats32BitIndex }
::= { mwrEnetPerfPortStats32BitTable 1 }
MwrEnetPerfPortStats32BitEntry ::= SEQUENCE {
mwrPortStats32BitIndex
INTEGER,
mwrPortStatsInOctet32Bit
Counter32,
mwrPortStatsInGoodPkts32Bit
Counter32,
mwrPortStatsInErrPkts32Bit
Counter32,
mwrPortStatsInDiscardPkts32Bit
Counter32,
mwrPortStatsOutOctets32Bit
Counter32,
mwrPortStatsOutGoodPkts32Bit
Counter32,
mwrPortStatsOutErrPkts32Bit
Counter32,
mwrPortStatsOutDiscardPkts32Bit
Counter32
}
mwrPortStats32BitIndex OBJECT-TYPE
SYNTAX INTEGER {
gi01 (1),
gi02 (2),
gi03 (3),
gi04 (4),
radio (5)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table index to ports carrying Ethernet packets."
::= { mwrEnetPerfPortStats32BitEntry 1 }
mwrPortStatsInOctet32Bit OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 32-bit counter representing the incoming octets."
::= { mwrEnetPerfPortStats32BitEntry 2 }
mwrPortStatsInGoodPkts32Bit OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 32-bit counter representing the incoming good packets."
::= { mwrEnetPerfPortStats32BitEntry 3 }
mwrPortStatsInErrPkts32Bit OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 32-bit counter representing the incoming error packets."
::= { mwrEnetPerfPortStats32BitEntry 4 }
mwrPortStatsInDiscardPkts32Bit OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 32-bit counter representing the incoming discarded packets."
::= { mwrEnetPerfPortStats32BitEntry 5 }
mwrPortStatsOutOctets32Bit OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 32-bit counter representing the outgoing octets."
::= { mwrEnetPerfPortStats32BitEntry 6 }
mwrPortStatsOutGoodPkts32Bit OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 32-bit counter representing the outgoing good packets."
::= { mwrEnetPerfPortStats32BitEntry 7 }
mwrPortStatsOutErrPkts32Bit OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 32-bit counter representing the outgoing error packets."
::= { mwrEnetPerfPortStats32BitEntry 8 }
mwrPortStatsOutDiscardPkts32Bit OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 32-bit counter representing the outgoing discarded packets."
::= { mwrEnetPerfPortStats32BitEntry 9 }
mwrEnetPerfRadioQStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrEnetPerfRadioQStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing radio queue statistics."
::= { mwrEthernetPerformance 3 }
mwrEnetPerfRadioQStatsEntry OBJECT-TYPE
SYNTAX MwrEnetPerfRadioQStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing radio queue statistics."
INDEX { mwrRadioQStatsIndex }
::= { mwrEnetPerfRadioQStatsTable 1 }
MwrEnetPerfRadioQStatsEntry ::= SEQUENCE {
mwrRadioQStatsIndex
QueueType,
mwrRadioQStatsInGoodPkts
Counter64,
mwrRadioQStatsInDiscardPkts
Counter64,
mwrRadioQStatsOutBwUtilization
Integer32,
mwrRadioQStatsInDataRate
Integer32,
mwrRadioQStatsThroughput
Integer32
}
mwrRadioQStatsIndex OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each of the 8 queues."
::= { mwrEnetPerfRadioQStatsEntry 1 }
mwrRadioQStatsInGoodPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current count of packets in queues."
::= { mwrEnetPerfRadioQStatsEntry 2 }
mwrRadioQStatsInDiscardPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current count of packets received in queues that were discarded due to queue overflow."
::= { mwrEnetPerfRadioQStatsEntry 3 }
mwrRadioQStatsOutBwUtilization OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ratio of egress data rate and user configured radio queue CIR."
::= { mwrEnetPerfRadioQStatsEntry 4 }
mwrRadioQStatsInDataRate OBJECT-TYPE
SYNTAX Integer32
UNITS "Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ingress data rate of the radio queue."
::= { mwrEnetPerfRadioQStatsEntry 5 }
mwrRadioQStatsThroughput OBJECT-TYPE
SYNTAX Integer32
UNITS "Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The throughput of the radio queue."
::= { mwrEnetPerfRadioQStatsEntry 6 }
mwrEnetPerfRadioQStats32BitTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrEnetPerfRadioQStats32BitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing 32-bit counters for radio queue statistics."
::= { mwrEthernetPerformance 4 }
mwrEnetPerfRadioQStats32BitEntry OBJECT-TYPE
SYNTAX MwrEnetPerfRadioQStats32BitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing 32-bit counters for radio queue statistics."
INDEX { mwrRadioQStats32BitIndex }
::= { mwrEnetPerfRadioQStats32BitTable 1 }
MwrEnetPerfRadioQStats32BitEntry ::= SEQUENCE {
mwrRadioQStats32BitIndex
QueueType,
mwrRadioQStatsInGoodPkts32Bit
Counter32,
mwrRadioQStatsDiscardPkts32Bit
Counter32
}
mwrRadioQStats32BitIndex OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each of the 8 queues."
::= { mwrEnetPerfRadioQStats32BitEntry 1 }
mwrRadioQStatsInGoodPkts32Bit OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 32-bit counter representing the current count of packets in queues."
::= { mwrEnetPerfRadioQStats32BitEntry 2 }
mwrRadioQStatsDiscardPkts32Bit OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 32-bit counter representing the current count of packets received in queues that were discarded due to queue overflow ."
::= { mwrEnetPerfRadioQStats32BitEntry 3 }
mwrDroppedPktsThreshold NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrPortThresholdAlarmIndex,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when the ethernet packet drops in an interface has exceeded user set limit."
::= { mwrEthernetNotifications 1 }
mwrRadioQDroppedPktsThreshold NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrRadioQThresholdAlarmIndex,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when Ethernet packet drops over radio traffic queue has exceeded the user configured limit. The mwrRadioQThresholdAlarmIndex varbind indicates specific queue number."
::= { mwrEthernetNotifications 2 }
mwrRadioQDepthThreshold NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrRadioQThresholdAlarmIndex,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when the data buffered in the specific radio traffic queue has exceeded the user set limit. The mwrRadioQThresholdAlarmIndex varbind indicates specific queue number."
::= { mwrEthernetNotifications 3 }
mwrOutBWUtilizationThreshold NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrPortThresholdAlarmIndex,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when the out bandwidth utilization of an interface has exceeded the user configured limit."
::= { mwrEthernetNotifications 4 }
mwrThroughputThreshold NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrPortThresholdAlarmIndex,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when the throughput of an interface has exceeded the user configured limit."
::= { mwrEthernetNotifications 5 }
mwrAcmManualMode OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the Adaptive Coding Modulation (ACM) Manual Mode."
::= { mwrAcmConfigurations 1 }
-- ----------------------------
-- mwrAcm
-- ----------------------------
mwrAcmState OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the Adaptive Code Modulation (ACM)."
DEFVAL { disabled }
::= { mwrAcmConfigurations 2 }
mwrAcmWaitToRestore OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the ACM wait to restore duration time in seconds."
::= { mwrAcmConfigurations 3 }
mwrAcmModeTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrAcmModeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing available Adaptive Code Modulation (ACM) tx profiles."
::= { mwrAcmConfigurations 4 }
mwrAcmModeEntry OBJECT-TYPE
SYNTAX MwrAcmModeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing available Adaptive Code Modulation (ACM) tx profiles."
INDEX { mwrAcmModeIndex }
::= { mwrAcmModeTable 1 }
MwrAcmModeEntry ::= SEQUENCE {
mwrAcmModeIndex
Integer32,
mwrAcmTxProfileName
DisplayString,
mwrAcmTxProfileRange
INTEGER
}
mwrAcmModeIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each Adaptive Code Modulation (ACM) tx profile. "
::= { mwrAcmModeEntry 1 }
mwrAcmTxProfileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Adaptive Code Modulation (ACM) tx profile name."
::= { mwrAcmModeEntry 2 }
mwrAcmTxProfileRange OBJECT-TYPE
SYNTAX INTEGER {
notAllowed (1),
allowed (2),
max (3),
min (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the range for the Adaptive Code Modulation (ACM) TX Profile."
DEFVAL { notAllowed }
::= { mwrAcmModeEntry 3 }
-- ----------------
-- mwrAcmTable
-- ----------------
mwrAcmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrAcmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing Adaptive Code Modulation (ACM) status."
::= { mwrAcmStatus 1 }
mwrAcmStatusEntry OBJECT-TYPE
SYNTAX MwrAcmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing Adaptive Code Modulation (ACM) status."
INDEX { mwrAcmStatusIndex }
::= { mwrAcmStatusTable 1 }
MwrAcmStatusEntry ::= SEQUENCE {
mwrAcmStatusIndex
RadioInstanceType,
mwrAcmActualTxProfile
DisplayString
}
mwrAcmStatusIndex OBJECT-TYPE
SYNTAX RadioInstanceType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each interface. "
::= { mwrAcmStatusEntry 1 }
mwrAcmActualTxProfile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..24))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A read-only string specifying the currently running ACM TX profile."
::= { mwrAcmStatusEntry 2 }
-- ----------------------------
-- mwrAcmDiagnostics
-- ----------------------------
mwrAcmDiagTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrAcmDiagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing ACM diagnostic settings."
::= { mwrAcmDiagnostics 1 }
mwrAcmDiagEntry OBJECT-TYPE
SYNTAX MwrAcmDiagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing ACM diagnostic settings."
INDEX { mwrAcmDiagIndex }
::= { mwrAcmDiagTable 1 }
MwrAcmDiagEntry ::= SEQUENCE {
mwrAcmDiagIndex
RadioInstanceType,
mwrAcmDiagnose
INTEGER,
mwrAcmDiagnosticResult
DisplayString
}
mwrAcmDiagIndex OBJECT-TYPE
SYNTAX RadioInstanceType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each radio channel if applicable."
::= { mwrAcmDiagEntry 1 }
mwrAcmDiagnose OBJECT-TYPE
SYNTAX INTEGER {
up (1),
down (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This service effecting object accepts either 'up' or 'down' to diagnose whether the modulation speed can be increased or decreased. Poll the mwrAcmDiagnosticResult object to determine the results."
::= { mwrAcmDiagEntry 2 }
mwrAcmDiagnosticResult OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result from ACM Diagnostic is read from this object."
::= { mwrAcmDiagEntry 3 }
mwrAcmConfigMismatch NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrEventInstanceIndex,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when ACM configuration mismatch between the link partners."
::= { mwrAcmNotifications 1 }
mwrAcmProfileLowered NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrAcmStatusIndex,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when system is executing ACM and working at a lower radio profile than the configured nominal radio profile."
::= { mwrAcmNotifications 2 }
mwrAcmProfileChanged NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrAcmStatusIndex,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when system is executing in ACM and has changed the radio profile."
::= { mwrAcmNotifications 3 }
mwrAtpcConfigurationsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrAtpcConfigurationsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing ATPC configurations."
::= { mwrAtpcConfigurations 1 }
mwrAtpcConfigurationsEntry OBJECT-TYPE
SYNTAX MwrAtpcConfigurationsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry containing ATPC configurations."
INDEX { mwrAtpcConfigIndex }
::= { mwrAtpcConfigurationsTable 1 }
MwrAtpcConfigurationsEntry ::= SEQUENCE {
mwrAtpcConfigIndex
RadioInstanceType,
mwrAtpcState
EnableType,
mwrAtpcCoordinatedPower
Integer32,
mwrAtpcCoordinatedPowerEnable
EnableType,
mwrAtpcMinTxPower
Integer32,
mwrAtpcMaxTxPower
Integer32,
mwrAtpcRslTarget
Integer32,
mwrAtpcRslTargetUseDefault
EnableType
}
mwrAtpcConfigIndex OBJECT-TYPE
SYNTAX RadioInstanceType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each of the radio channel instance."
::= { mwrAtpcConfigurationsEntry 1 }
-- ----------------------------
-- mwrAtpc
-- ----------------------------
mwrAtpcState OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the Adaptive Transmit Power Control (ATPC) feature is enabled."
DEFVAL { disabled }
::= { mwrAtpcConfigurationsEntry 2 }
mwrAtpcCoordinatedPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the value at which the system will transmit if the ATPC and the coordinated power are enabled. This is only if the system is transmitting the maximum power for 5 minutes.
The value is multiplied by 10. e.g. A display of 133 is actually 13.3 dB."
DEFVAL { 0 }
::= { mwrAtpcConfigurationsEntry 3 }
mwrAtpcCoordinatedPowerEnable OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether Adaptive Transmit Power Control (ATPC) coordinated power option is enabled."
DEFVAL { disabled }
::= { mwrAtpcConfigurationsEntry 4 }
mwrAtpcMinTxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the minimum ATPC transmit power in dB x 10."
::= { mwrAtpcConfigurationsEntry 5 }
mwrAtpcMaxTxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the maximum ATPC transmit power in dB x 10. When ATPC is enabled, transmit power range will be between ATPC min. and ATPC max. power."
::= { mwrAtpcConfigurationsEntry 6 }
mwrAtpcRslTarget OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures Received Signal Level that should be maintained by the link by adjusting the transmit power when ATPC is enabled."
::= { mwrAtpcConfigurationsEntry 7 }
mwrAtpcRslTargetUseDefault OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is enabled the default RSL target will be used instead of the configured mwrAtpcRslTarget. The mwrAtpcDefaultRslTarget displays the default value."
::= { mwrAtpcConfigurationsEntry 8 }
mwrAtpcStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrAtpcStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing ATPC status."
::= { mwrAtpcStatus 1 }
mwrAtpcStatusEntry OBJECT-TYPE
SYNTAX MwrAtpcStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing ATPC status."
INDEX { mwrAtpcStatusIndex }
::= { mwrAtpcStatusTable 1 }
MwrAtpcStatusEntry ::= SEQUENCE {
mwrAtpcStatusIndex
RadioInstanceType,
mwrAtpcRunningStatus
INTEGER,
mwrAtpcDefaultRslTarget
Integer32,
mwrAtpcActualMinTxPower
Integer32,
mwrAtpcActualMaxTxPower
Integer32,
mwrAtpcActualCoordinatedPower
Integer32,
mwrAtpcPeerRslTarget
Integer32,
mwrAtpcMinRslTarget
Integer32,
mwrAtpcMaxRslTarget
Integer32,
mwrAtpcPeerRsl
Integer32
}
mwrAtpcStatusIndex OBJECT-TYPE
SYNTAX RadioInstanceType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each of the radio instance."
::= { mwrAtpcStatusEntry 1 }
mwrAtpcRunningStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled (1),
disabledAuto (2),
running (3),
runningToggling (4),
suspended (5),
suspendedLostComm (6),
suspendedRadioDown (7),
suspendedRadioMuted (8),
suspendedRadioLoopback (9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the actual condition of ATPC:
- disabled: Configuration is set to off.
- disabledAuto: Feature was automatically disabled and is transmitting at coordinated power.
- running: Feature is running normally.
- runningToggling: Feature is toggling between maximum and minimum power to recover from a loss of mod sync.
- suspended: Feature was suspended.
- suspendedLostComm: Feature is suspended because communication is lost with peer ATPC.
- suspendedRadioDown: Feature is suspended because the radio is down.
- suspendedRadioMuted: Feature is suspended because the radio is muted.
- suspendedRadioLoopback: Feature is suspended because the radio is in loopback mode."
::= { mwrAtpcStatusEntry 2 }
mwrAtpcDefaultRslTarget OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the default value of the Received Signal Level target when ATPC is enabled."
::= { mwrAtpcStatusEntry 3 }
mwrAtpcActualMinTxPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the running configuration for ATPC min tx power."
::= { mwrAtpcStatusEntry 4 }
mwrAtpcActualMaxTxPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the running configuration for ATPC max tx power."
::= { mwrAtpcStatusEntry 5 }
mwrAtpcActualCoordinatedPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the running configuration of the coordinated power.
The value is multiplied by 10. e.g. A display of 133 is actually 13.3 dB."
::= { mwrAtpcStatusEntry 6 }
mwrAtpcPeerRslTarget OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the peer Received Signal Level target when ATPC is enabled."
::= { mwrAtpcStatusEntry 7 }
mwrAtpcMinRslTarget OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents the minimum RSL target value."
::= { mwrAtpcStatusEntry 8 }
mwrAtpcMaxRslTarget OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents the maximum RSL target value."
::= { mwrAtpcStatusEntry 9 }
mwrAtpcPeerRsl OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the peer actual RSL value. Divide the value by 10 to get the actual RSL value. Once this number is divided by 10 the units are dB. For example -352 is actually -35.2dB"
::= { mwrAtpcStatusEntry 10 }
mwrAtpcConfigMismatch NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrEventInstanceIndex,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when ATPC configuration mismatch has occurred between link partners."
::= { mwrAtpcNotifications 1 }
mwrAtpcAutoDisabled NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrAtpcStatusIndex,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when ATPC is automatically disabled due to coordinated power condition. When this notification is raised the radio will be transmitting at coordinated power. The mwrAtpcStatusIndex varbind indicates the radio instance."
::= { mwrAtpcNotifications 2 }
mwrBacRecordAvgPeriod OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the average period used for computing the running average BAC gain and uncompressed ratio. Default average period is set to 10 seconds. "
::= { mwrCompressionConfigurations 1 }
mwrBacTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrBacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing Bandwidth Acceleration entries."
::= { mwrCompressionConfigurations 2 }
mwrBacEntry OBJECT-TYPE
SYNTAX MwrBacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains Bandwidth Acceleration entries."
INDEX { mwrBacQIndex }
::= { mwrBacTable 1 }
MwrBacEntry ::= SEQUENCE {
mwrBacQIndex
QueueType,
mwrBacQEnable
EnableType,
mwrBacQBlockSize
Integer32,
mwrBacRecordLogging
EnableType
}
mwrBacQIndex OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each of the 8 radio egress Queues."
::= { mwrBacEntry 1 }
mwrBacQEnable OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure queue compression state to disable/enable."
::= { mwrBacEntry 2 }
mwrBacQBlockSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure queue compression block size (256...8000). Block size has to be in increments of 64 bytes. Otherwise it will be rounded off to nearest 64 bytes.
Valid block sizes are <256 512 1024 4032 8000>"
::= { mwrBacEntry 3 }
mwrBacRecordLogging OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enables/disables logging of BAC related statistics like Maximum BAC gain and Maximum uncompressed ratio
on a per queue basis to syslog and flashlog."
::= { mwrBacEntry 4 }
mwrHcQTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrHcQEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing Header Compression settings for each queue, the configuration corresponds to the egress QoS of radio port."
::= { mwrCompressionConfigurations 3 }
mwrHcQEntry OBJECT-TYPE
SYNTAX MwrHcQEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing Header Compression settings for each queue."
INDEX { mwrHcQIndex }
::= { mwrHcQTable 1 }
MwrHcQEntry ::= SEQUENCE {
mwrHcQIndex
QueueType,
mwrHcQ1
EnableType,
mwrHcQ2
EnableType,
mwrHcQ3
EnableType,
mwrHcQ4
EnableType,
mwrHcQ5
EnableType,
mwrHcQ6
EnableType,
mwrHcQ7
EnableType,
mwrHcQ8
EnableType,
mwrHcQRowStatus
RowStatus
}
mwrHcQIndex OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies Header Compression queue index for each radio queue."
::= { mwrHcQEntry 1 }
mwrHcQ1 OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the Header Compression on queue 1."
::= { mwrHcQEntry 2 }
mwrHcQ2 OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the Header Compression on queue 2."
::= { mwrHcQEntry 3 }
mwrHcQ3 OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the Header Compression on queue 3."
::= { mwrHcQEntry 4 }
mwrHcQ4 OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the Header Compression on queue 4."
::= { mwrHcQEntry 5 }
mwrHcQ5 OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the Header Compression on queue 5."
::= { mwrHcQEntry 6 }
mwrHcQ6 OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the Header Compression on queue 6."
::= { mwrHcQEntry 7 }
mwrHcQ7 OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the Header Compression on queue 7."
::= { mwrHcQEntry 8 }
mwrHcQ8 OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the Header Compression on queue 8."
::= { mwrHcQEntry 9 }
mwrHcQRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Header Compression table Row Status. This object is used to apply Header Compression settings for all queues simultaneously."
::= { mwrHcQEntry 10 }
mwrBacStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrBacStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing Bandwidth Acceleration status entries."
::= { mwrCompressionStatus 1 }
mwrBacStatusEntry OBJECT-TYPE
SYNTAX MwrBacStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains Bandwidth Acceleration status entries."
INDEX { mwrBacStatusQIndex }
::= { mwrBacStatusTable 1 }
MwrBacStatusEntry ::= SEQUENCE {
mwrBacStatusQIndex
QueueType,
mwrBacUncompressedRatio
DisplayString,
mwrBacGain
DisplayString
}
mwrBacStatusQIndex OBJECT-TYPE
SYNTAX QueueType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each of the 8 Queues."
::= { mwrBacStatusEntry 1 }
mwrBacUncompressedRatio OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Running average Uncompressed ratio is calculated by collecting n samples of bytes uncompressed and bytes in to queue over specified average period in percentage."
::= { mwrBacStatusEntry 2 }
mwrBacGain OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Running Average BAC gain is the sum of all bytes getting into the compressor divided by the sum of all compressed and uncompressed bytes calculated over an average period."
::= { mwrBacStatusEntry 3 }
mwrEventConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrEventConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of alarm configuration"
::= { mwrEventsConfigurations 1 }
mwrEventConfigEntry OBJECT-TYPE
SYNTAX MwrEventConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of alarm configuration"
INDEX { mwrEventConfigIndex,
mwrEventInstanceIndex }
::= { mwrEventConfigTable 1 }
MwrEventConfigEntry ::= SEQUENCE {
mwrEventConfigIndex
Unsigned32,
mwrEventInstanceIndex
Unsigned32,
mwrEventConfigSeverity
INTEGER,
mwrEventName
DisplayString,
mwrAlarmConfigState
EnableType,
mwrTrapConfigState
EnableType,
mwrLogEventState
EnableType
}
mwrEventConfigIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each alarm."
::= { mwrEventConfigEntry 1 }
mwrEventInstanceIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each instance of an alarm."
::= { mwrEventConfigEntry 2 }
mwrEventConfigSeverity OBJECT-TYPE
SYNTAX INTEGER {
clear (0),
warning (1),
minor (2),
major (3),
critical (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The severity of the alarm as minor, major or critical."
::= { mwrEventConfigEntry 3 }
mwrEventName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents the event name."
::= { mwrEventConfigEntry 4 }
mwrAlarmConfigState OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The state of the alarm which can be either enabled or disabled."
::= { mwrEventConfigEntry 5 }
mwrTrapConfigState OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The state of the trap which can be either enabled or disabled."
::= { mwrEventConfigEntry 6 }
mwrLogEventState OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable or disable logging the events."
::= { mwrEventConfigEntry 7 }
--
-- mwrLogs
--
mwrEventLogEnable OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether event log is enabled."
DEFVAL { enabled }
::= { mwrLogsConfigurations 1 }
mwrPerfmLogEnable OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether performance log is enabled."
DEFVAL { enabled }
::= { mwrLogsConfigurations 2 }
mwrPerfmLogInterval OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Performance statistics are logged periodically by this interval. The interval can be up to 00:15:00 (15 minutes) and as short as 00:00:1 (1 seconds)."
::= { mwrLogsConfigurations 3 }
mwrSysLogServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrSysLogServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The syslog server table."
::= { mwrLogsConfigurations 4 }
mwrSysLogServerEntry OBJECT-TYPE
SYNTAX MwrSysLogServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The syslog server table entry."
INDEX { mwrSysLogServerIndex }
::= { mwrSysLogServerTable 1 }
MwrSysLogServerEntry ::= SEQUENCE {
mwrSysLogServerIndex
Integer32,
mwrSysLogEnable
EnableType,
mwrSysLogHostDomain
InetAddressType,
mwrSysLogHostAddress
InetAddress
}
mwrSysLogServerIndex OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The syslog server table index."
::= { mwrSysLogServerEntry 1 }
mwrSysLogEnable OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether sys log is enabled."
::= { mwrSysLogServerEntry 2 }
mwrSysLogHostDomain OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates sys log host inet address type. Valid types are ipv4 or ipv6. "
::= { mwrSysLogServerEntry 3 }
mwrSysLogHostAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates sys log host inet address octet string."
::= { mwrSysLogServerEntry 4 }
mwrPmRspiThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrPmRspiThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Performance Monitoring table for Radio Synchronous Physical Interface thresholds."
::= { mwrPMConfigurations 1 }
mwrPmRspiThresholdEntry OBJECT-TYPE
SYNTAX MwrPmRspiThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains entries for Radio Synchronous Physical Interface thresholds."
INDEX { mwrPmRspiThrIndex }
::= { mwrPmRspiThresholdTable 1 }
MwrPmRspiThresholdEntry ::= SEQUENCE {
mwrPmRspiThrIndex
RadioInstanceType,
mwrPmRLT1
Integer32,
mwrPmRLT2
Integer32,
mwrPmRLT3
Integer32,
mwrPmRLT4
Integer32,
mwrPmTLT1
Integer32,
mwrPmTLT2
Integer32,
mwrPmRspiThrRowStatus
RowStatus
}
mwrPmRspiThrIndex OBJECT-TYPE
SYNTAX RadioInstanceType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index to PM RSPI Threshold table."
::= { mwrPmRspiThresholdEntry 1 }
mwrPmRLT1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive Level Threshold 1, represents the value of the first received power level threshold."
::= { mwrPmRspiThresholdEntry 2 }
mwrPmRLT2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive Level Threshold 2, represents the value of the second received power level threshold."
::= { mwrPmRspiThresholdEntry 3 }
mwrPmRLT3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive Level Threshold 3, represents the value of the third received power level threshold."
::= { mwrPmRspiThresholdEntry 4 }
mwrPmRLT4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive Level Threshold 4, represents the value of the fourth received power level threshold."
::= { mwrPmRspiThresholdEntry 5 }
mwrPmTLT1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit Level Threshold 1, represents the value of the first transmitted power level threshold."
::= { mwrPmRspiThresholdEntry 6 }
mwrPmTLT2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit Level Threshold 2, represents the value of the second transmitted power level threshold."
::= { mwrPmRspiThresholdEntry 7 }
mwrPmRspiThrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for applying all RSPI thresholds simultaneously. Set RowStatus to NotInService, make changes to all or some threshold values and then change RowStatus back to Active."
::= { mwrPmRspiThresholdEntry 8 }
mwrPmBwThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrPmBwThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Performance monitoring out bandwidth utilization thresholds table."
::= { mwrPMConfigurations 2 }
mwrPmBwThresholdEntry OBJECT-TYPE
SYNTAX MwrPmBwThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains entries for performance monitoring out bandwidth utilization thresholds."
INDEX { mwrPmBWThrIndex }
::= { mwrPmBwThresholdTable 1 }
MwrPmBwThresholdEntry ::= SEQUENCE {
mwrPmBWThrIndex
Integer32,
mwrPmBWT1
Integer32,
mwrPmBWT2
Integer32,
mwrPmBWT3
Integer32,
mwrPmBWT4
Integer32,
mwrPmBWT5
Integer32,
mwrPmBWT6
Integer32,
mwrPmBWT7
Integer32,
mwrPmBWT8
Integer32,
mwrPmBWT9
Integer32,
mwrPmBWT10
Integer32,
mwrPmBWTRowStatus
RowStatus
}
mwrPmBWThrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index to PM out BW Threshold table. Index 1 represents the radio port."
::= { mwrPmBwThresholdEntry 1 }
mwrPmBWT1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring out BW utilization threshold 1."
::= { mwrPmBwThresholdEntry 2 }
mwrPmBWT2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring out BW utilization threshold 2."
::= { mwrPmBwThresholdEntry 3 }
mwrPmBWT3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring out BW utilization threshold 3."
::= { mwrPmBwThresholdEntry 4 }
mwrPmBWT4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring out BW utilization threshold 4."
::= { mwrPmBwThresholdEntry 5 }
mwrPmBWT5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring out BW utilization threshold 5."
::= { mwrPmBwThresholdEntry 6 }
mwrPmBWT6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring out BW utilization threshold 6."
::= { mwrPmBwThresholdEntry 7 }
mwrPmBWT7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring out BW utilization threshold 7."
::= { mwrPmBwThresholdEntry 8 }
mwrPmBWT8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring out BW utilization threshold 8."
::= { mwrPmBwThresholdEntry 9 }
mwrPmBWT9 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring out BW utilization threshold 9."
::= { mwrPmBwThresholdEntry 10 }
mwrPmBWT10 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring out BW utilization threshold 10."
::= { mwrPmBwThresholdEntry 11 }
mwrPmBWTRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for applying all PM bandwidth threshold settings simultaneously. Set RowStatus to NotInService, make changes to all or some threshold values and then change RowStatus back to Active."
::= { mwrPmBwThresholdEntry 12 }
mwrPmTpThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrPmTpThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Performance monitoring throughput thresholds table."
::= { mwrPMConfigurations 3 }
mwrPmTpThresholdEntry OBJECT-TYPE
SYNTAX MwrPmTpThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains entries for performance monitoring throughput thresholds."
INDEX { mwrPmTPThrIndex }
::= { mwrPmTpThresholdTable 1 }
MwrPmTpThresholdEntry ::= SEQUENCE {
mwrPmTPThrIndex
Integer32,
mwrPmTPT1
Integer32,
mwrPmTPT2
Integer32,
mwrPmTPT3
Integer32,
mwrPmTPT4
Integer32,
mwrPmTPT5
Integer32,
mwrPmTPT6
Integer32,
mwrPmTPT7
Integer32,
mwrPmTPT8
Integer32,
mwrPmTPT9
Integer32,
mwrPmTPT10
Integer32,
mwrPmTPTRowStatus
RowStatus
}
mwrPmTPThrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index to PM throughput Threshold table. Index 1 represents the radio port."
::= { mwrPmTpThresholdEntry 1 }
mwrPmTPT1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring throughput threshold 1."
::= { mwrPmTpThresholdEntry 2 }
mwrPmTPT2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring throughput threshold 2."
::= { mwrPmTpThresholdEntry 3 }
mwrPmTPT3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring throughput threshold 3."
::= { mwrPmTpThresholdEntry 4 }
mwrPmTPT4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring throughput threshold 4."
::= { mwrPmTpThresholdEntry 5 }
mwrPmTPT5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring throughput threshold 5."
::= { mwrPmTpThresholdEntry 6 }
mwrPmTPT6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring throughput threshold 6."
::= { mwrPmTpThresholdEntry 7 }
mwrPmTPT7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring throughput threshold 7."
::= { mwrPmTpThresholdEntry 8 }
mwrPmTPT8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring throughput threshold 8."
::= { mwrPmTpThresholdEntry 9 }
mwrPmTPT9 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring throughput threshold 9."
::= { mwrPmTpThresholdEntry 10 }
mwrPmTPT10 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The performance monitoring throughput threshold 10."
::= { mwrPmTpThresholdEntry 11 }
mwrPmTPTRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for applying all PM throughput threshold settings simultaneously. Set RowStatus to NotInService, make changes to all or some threshold values and then change RowStatus back to Active."
::= { mwrPmTpThresholdEntry 12 }
mwrPmAdvThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrPmAdvThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The advanced performance monitoring thresholds table."
::= { mwrPMConfigurations 4 }
mwrPmAdvThresholdEntry OBJECT-TYPE
SYNTAX MwrPmAdvThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The advanced performance monitoring thresholds entries."
INDEX { mwrPmAdvThrIndex }
::= { mwrPmAdvThresholdTable 1 }
MwrPmAdvThresholdEntry ::= SEQUENCE {
mwrPmAdvThrIndex
Integer32,
mwrPmAdvTxHitsT1
Integer32,
mwrPmAdvRxHitsT1
Integer32,
mwrPmAdvRowStatus
RowStatus
}
mwrPmAdvThrIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The advanced performance monitoring thresholds table index. Index 1 represents the radio port."
::= { mwrPmAdvThresholdEntry 1 }
mwrPmAdvTxHitsT1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The advanced performance monitoring Tx hits threshold 1."
::= { mwrPmAdvThresholdEntry 2 }
mwrPmAdvRxHitsT1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The advanced performance monitoring Rx hits threshold 1."
::= { mwrPmAdvThresholdEntry 3 }
mwrPmAdvRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used for applying all PM advanced threshold settings simultaneously. Set RowStatus to NotInService, make changes to all threshold values and then change back RowStatus to Active."
::= { mwrPmAdvThresholdEntry 4 }
mwrPmRspiTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrPmRspiEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Performance Monitoring table for Radio Synchronous Physical Interface."
::= { mwrPMStatus 1 }
mwrPmRspiEntry OBJECT-TYPE
SYNTAX MwrPmRspiEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains information for Radio Synchronous Physical Interface. The table is indexed by the granularity period and
by the interval number. 22 rows are always presents, 20 are the historical
measurements for 16 intervals in the quarter granularity and 4 intervals
in the 24 hours granularity period. 2 rows represent the current measures."
INDEX { mwrPmRspiStatusIndex,
mwrPmRspiInterval,
mwrPmRspiIntervalID }
::= { mwrPmRspiTable 1 }
MwrPmRspiEntry ::= SEQUENCE {
mwrPmRspiStatusIndex
RadioInstanceType,
mwrPmRspiInterval
PMIntervalType,
mwrPmRspiIntervalID
Integer32,
mwrPmRspiMeasSuspect
TruthValue,
mwrPmRspiMeasIntervalStatus
INTEGER,
mwrPmRspiMeasTimeLength
Integer32,
mwrPmRspiMeasTLTMMin
Integer32,
mwrPmRspiMeasTLTMMax
Integer32,
mwrPmRspiMeasTLTS1
Integer32,
mwrPmRspiMeasTLTS2
Integer32,
mwrPmRspiMeasRLTMMin
Integer32,
mwrPmRspiMeasRLTMMax
Integer32,
mwrPmRspiMeasRLTS1
Integer32,
mwrPmRspiMeasRLTS2
Integer32,
mwrPmRspiMeasRLTS3
Integer32,
mwrPmRspiMeasRLTS4
Integer32
}
mwrPmRspiStatusIndex OBJECT-TYPE
SYNTAX RadioInstanceType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each of the radio instance."
::= { mwrPmRspiEntry 1 }
mwrPmRspiInterval OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interval period of the row. Quarter means the 15 minutes interval and day means the 24 hours interval."
::= { mwrPmRspiEntry 2 }
mwrPmRspiIntervalID OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interval identifier of the row, from 1 (last quarter) to 16 (oldest quarter) for the 15-minute
and from 1 (yesterday) to 4 (4 days ago) for the 24-hour.
Value 0 can be used to retrieve current measurements, according to the requested granularity."
::= { mwrPmRspiEntry 3 }
mwrPmRspiMeasSuspect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Any problem that invalidates the measurement."
::= { mwrPmRspiEntry 4 }
mwrPmRspiMeasIntervalStatus OBJECT-TYPE
SYNTAX INTEGER {
invalid (1),
valid (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication if the interval is a valid measurement. When the system comes up, all the previous intervals are invalid."
::= { mwrPmRspiEntry 5 }
mwrPmRspiMeasTimeLength OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval duration in seconds."
::= { mwrPmRspiEntry 6 }
mwrPmRspiMeasTLTMMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmitted power level tide mark low value."
::= { mwrPmRspiEntry 7 }
mwrPmRspiMeasTLTMMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmitted power level tide mark high value."
::= { mwrPmRspiEntry 8 }
mwrPmRspiMeasTLTS1 OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the first transmitted power level threshold."
::= { mwrPmRspiEntry 9 }
mwrPmRspiMeasTLTS2 OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the second transmitted power level threshold."
::= { mwrPmRspiEntry 10 }
mwrPmRspiMeasRLTMMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The received power level tide mark low value."
::= { mwrPmRspiEntry 11 }
mwrPmRspiMeasRLTMMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The received power level tide mark high value."
::= { mwrPmRspiEntry 12 }
mwrPmRspiMeasRLTS1 OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds below the first received power level threshold."
::= { mwrPmRspiEntry 13 }
mwrPmRspiMeasRLTS2 OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds below the second received power level threshold."
::= { mwrPmRspiEntry 14 }
mwrPmRspiMeasRLTS3 OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds below the third received power level threshold."
::= { mwrPmRspiEntry 15 }
mwrPmRspiMeasRLTS4 OBJECT-TYPE
SYNTAX Integer32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds below the fourth received power level threshold."
::= { mwrPmRspiEntry 16 }
mwrPmBWTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrPmBWEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing performance monitoring measurements in 15 min and 24 hrs intervals for out BW utilization."
::= { mwrPMStatus 2 }
mwrPmBWEntry OBJECT-TYPE
SYNTAX MwrPmBWEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entries containing performance monitoring measurements in 15 min and 24 hrs intervals for out BW utilization."
INDEX { mwrPmBWStatusIndex,
mwrPmBWInterval,
mwrPmBWIntervalID }
::= { mwrPmBWTable 1 }
MwrPmBWEntry ::= SEQUENCE {
mwrPmBWStatusIndex
Integer32,
mwrPmBWInterval
PMIntervalType,
mwrPmBWIntervalID
Integer32,
mwrPmBWMeasSuspect
TruthValue,
mwrPmBWMeasIntervalStatus
INTEGER,
mwrPmBWMeasTimeLength
Integer32,
mwrPmMeasBWTS1
Integer32,
mwrPmMeasBWTS2
Integer32,
mwrPmMeasBWTS3
Integer32,
mwrPmMeasBWTS4
Integer32,
mwrPmMeasBWTS5
Integer32,
mwrPmMeasBWTS6
Integer32,
mwrPmMeasBWTS7
Integer32,
mwrPmMeasBWTS8
Integer32,
mwrPmMeasBWTS9
Integer32,
mwrPmMeasBWTS10
Integer32
}
mwrPmBWStatusIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The performance monitoring out BW utilization measurements table index. Index 1 represents the radio port."
::= { mwrPmBWEntry 1 }
mwrPmBWInterval OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interval period of the row. Quarter means the 15 minutes interval and day means the 24 hours interval."
::= { mwrPmBWEntry 2 }
mwrPmBWIntervalID OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interval identifier of the row, from 1 (last quarter) to 16 (oldest quarter) for the 15-minute
and from 1 (yesterday) to 4 (4 days ago) for the 24-hour.
Value 0 can be used to retrieve current measurements, according to the requested granularity."
::= { mwrPmBWEntry 3 }
mwrPmBWMeasSuspect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Any problem that invalidates the measurement."
::= { mwrPmBWEntry 4 }
mwrPmBWMeasIntervalStatus OBJECT-TYPE
SYNTAX INTEGER {
invalid (1),
valid (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication if the interval is a valid measurement. When the system comes up, all the previous intervals are invalid."
::= { mwrPmBWEntry 5 }
mwrPmBWMeasTimeLength OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval duration in seconds."
::= { mwrPmBWEntry 6 }
mwrPmMeasBWTS1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the first BW utilization threshold."
::= { mwrPmBWEntry 7 }
mwrPmMeasBWTS2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the second BW utilization threshold."
::= { mwrPmBWEntry 8 }
mwrPmMeasBWTS3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the third BW utilization threshold."
::= { mwrPmBWEntry 9 }
mwrPmMeasBWTS4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the fourth BW utilization threshold."
::= { mwrPmBWEntry 10 }
mwrPmMeasBWTS5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the fifth BW utilization threshold."
::= { mwrPmBWEntry 11 }
mwrPmMeasBWTS6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the sixth BW utilization threshold."
::= { mwrPmBWEntry 12 }
mwrPmMeasBWTS7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the seventh BW utilization threshold."
::= { mwrPmBWEntry 13 }
mwrPmMeasBWTS8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the eighth BW utilization threshold."
::= { mwrPmBWEntry 14 }
mwrPmMeasBWTS9 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the ninth BW utilization threshold."
::= { mwrPmBWEntry 15 }
mwrPmMeasBWTS10 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the tenth BW utilization threshold."
::= { mwrPmBWEntry 16 }
mwrPmTPTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrPmTPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing performance monitoring measurements in 15 min and 24 hrs intervals for throughput."
::= { mwrPMStatus 3 }
mwrPmTPEntry OBJECT-TYPE
SYNTAX MwrPmTPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry containing performance monitoring throughput measurements in 15 min and 24 hrs intervals."
INDEX { mwrPmTPStatusIndex,
mwrPmTPInterval,
mwrPmTPIntervalID }
::= { mwrPmTPTable 1 }
MwrPmTPEntry ::= SEQUENCE {
mwrPmTPStatusIndex
Integer32,
mwrPmTPInterval
PMIntervalType,
mwrPmTPIntervalID
Integer32,
mwrPmTPMeasSuspect
TruthValue,
mwrPmTPMeasIntervalStatus
INTEGER,
mwrPmTPMeasTimeLength
Integer32,
mwrPmMeasTPTS1
Integer32,
mwrPmMeasTPTS2
Integer32,
mwrPmMeasTPTS3
Integer32,
mwrPmMeasTPTS4
Integer32,
mwrPmMeasTPTS5
Integer32,
mwrPmMeasTPTS6
Integer32,
mwrPmMeasTPTS7
Integer32,
mwrPmMeasTPTS8
Integer32,
mwrPmMeasTPTS9
Integer32,
mwrPmMeasTPTS10
Integer32
}
mwrPmTPStatusIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The performance monitoring throughput measurements table index. Index 1 represents the radio port."
::= { mwrPmTPEntry 1 }
mwrPmTPInterval OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interval period of the row. Quarter means the 15 minutes interval and day means the 24 hours interval."
::= { mwrPmTPEntry 2 }
mwrPmTPIntervalID OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interval identifier of the row, from 1 (last quarter) to 16 (oldest quarter) for the 15-minute
and from 1 (yesterday) to 4 (4 days ago) for the 24-hour.
Value 0 can be used to retrieve current measurements, according to the requested granularity."
::= { mwrPmTPEntry 3 }
mwrPmTPMeasSuspect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Any problem that invalidates the measurement."
::= { mwrPmTPEntry 4 }
mwrPmTPMeasIntervalStatus OBJECT-TYPE
SYNTAX INTEGER {
invalid (1),
valid (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication if the interval is a valid measurement. When the system comes up, all the previous intervals are invalid."
::= { mwrPmTPEntry 5 }
mwrPmTPMeasTimeLength OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval duration in seconds."
::= { mwrPmTPEntry 6 }
mwrPmMeasTPTS1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the first throughput threshold."
::= { mwrPmTPEntry 7 }
mwrPmMeasTPTS2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the second throughput threshold."
::= { mwrPmTPEntry 8 }
mwrPmMeasTPTS3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the third throughput threshold."
::= { mwrPmTPEntry 9 }
mwrPmMeasTPTS4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the fourth throughput threshold."
::= { mwrPmTPEntry 10 }
mwrPmMeasTPTS5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the fifth throughput threshold."
::= { mwrPmTPEntry 11 }
mwrPmMeasTPTS6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the sixth throughput threshold."
::= { mwrPmTPEntry 12 }
mwrPmMeasTPTS7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the seventh throughput threshold."
::= { mwrPmTPEntry 13 }
mwrPmMeasTPTS8 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the eighth throughput threshold."
::= { mwrPmTPEntry 14 }
mwrPmMeasTPTS9 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the ninth throughput threshold."
::= { mwrPmTPEntry 15 }
mwrPmMeasTPTS10 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds above the tenth throughput threshold."
::= { mwrPmTPEntry 16 }
mwrPmAdvTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrPmAdvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The advanced performance monitoring measurements table."
::= { mwrPMStatus 4 }
mwrPmAdvEntry OBJECT-TYPE
SYNTAX MwrPmAdvEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The advanced performance monitoring measurements table entries."
INDEX { mwrPmAdvStatusIndex,
mwrPmAdvInterval,
mwrPmAdvIntervalID }
::= { mwrPmAdvTable 1 }
MwrPmAdvEntry ::= SEQUENCE {
mwrPmAdvStatusIndex
Integer32,
mwrPmAdvInterval
PMIntervalType,
mwrPmAdvIntervalID
Integer32,
mwrPmAdvMeasSuspect
TruthValue,
mwrPmAdvMeasIntervalStatus
INTEGER,
mwrPmAdvMeasTimeLength
Integer32,
mwrPmAdvTxCapPeak
Integer32,
mwrPmAdvTxCapRatio
Integer32,
mwrPmAdvTxCapAvg
Integer32,
mwrPmAdvTxCapAvgRatio
Integer32,
mwrPmAdvTxCapHits
Integer32,
mwrPmAdvRxCapPeak
Integer32,
mwrPmAdvRxCapRatio
Integer32,
mwrPmAdvRxCapAvg
Integer32,
mwrPmAdvRxCapHits
Integer32
}
mwrPmAdvStatusIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The advanced performance monitoring measurements table index. Index 1 represents the radio port."
::= { mwrPmAdvEntry 1 }
mwrPmAdvInterval OBJECT-TYPE
SYNTAX PMIntervalType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interval period of the row. Quarter means the 15 minutes interval and day means the 24 hours interval."
::= { mwrPmAdvEntry 2 }
mwrPmAdvIntervalID OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interval identifier of the row, from 1 (last quarter) to 16 (oldest quarter) for the 15-minute
and from 1 (yesterday) to 4 (4 days ago) for the 24-hour.
Value 0 can be used to retrieve current measurements, according to the requested granularity."
::= { mwrPmAdvEntry 3 }
mwrPmAdvMeasSuspect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Any problem that invalidates the measurement."
::= { mwrPmAdvEntry 4 }
mwrPmAdvMeasIntervalStatus OBJECT-TYPE
SYNTAX INTEGER {
invalid (1),
valid (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication if the interval is a valid measurement. When the system comes up, all the previous intervals are invalid."
::= { mwrPmAdvEntry 5 }
mwrPmAdvMeasTimeLength OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interval duration in seconds."
::= { mwrPmAdvEntry 6 }
mwrPmAdvTxCapPeak OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second peak transmitted capacity during the time interval."
::= { mwrPmAdvEntry 7 }
mwrPmAdvTxCapRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of peak transmitted capacity
referred to the total allowed capacity
during the time interval.
"
::= { mwrPmAdvEntry 8 }
mwrPmAdvTxCapAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second average transmitted capacity
during the time interval.
"
::= { mwrPmAdvEntry 9 }
mwrPmAdvTxCapAvgRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of average transmitted capacity
during the time interval."
::= { mwrPmAdvEntry 10 }
mwrPmAdvTxCapHits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds where the transmitted
capacity has overcome a configurable
threshold during the time interval.
"
::= { mwrPmAdvEntry 11 }
mwrPmAdvRxCapPeak OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second peak received capacity
during the time interval.
"
::= { mwrPmAdvEntry 12 }
mwrPmAdvRxCapRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of peak received capacity
referred to the total allowed capacity
during the time interval."
::= { mwrPmAdvEntry 13 }
mwrPmAdvRxCapAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second average received capacity
during the time interval."
::= { mwrPmAdvEntry 14 }
mwrPmAdvRxCapHits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds where the received
capacity has overcome a configurable
threshold during the time interval.
"
::= { mwrPmAdvEntry 15 }
-- ------------------------------
-- mwrManagementSessions
-- ------------------------------
mwrUserSessionTable OBJECT-TYPE
SYNTAX SEQUENCE OF MwrUserSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of user sessions"
::= { mwrUserStatus 1 }
mwrUserSessionEntry OBJECT-TYPE
SYNTAX MwrUserSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"User session entry"
INDEX { mwrUserIndex }
::= { mwrUserSessionTable 1 }
MwrUserSessionEntry ::= SEQUENCE {
mwrUserIndex
INTEGER,
mwrUserName
DisplayString,
mwrUserConnectionType
DisplayString,
mwrUserConnectionState
INTEGER
}
mwrUserIndex OBJECT-TYPE
SYNTAX INTEGER {
user1 (1),
user2 (2),
user3 (3),
user4 (4),
user5 (5),
user6 (6),
user7 (7),
user8 (8),
user9 (9),
user10 (10),
user11 (11),
user12 (12),
user13 (13),
user14 (14),
user15 (15),
user16 (16),
user17 (17),
user18 (18),
user19 (19),
user20 (20)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each user."
::= { mwrUserSessionEntry 1 }
mwrUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The username of a management session using Telnet or HTTP. The session state variable must be checked to determine if the management session is currently in progress."
::= { mwrUserSessionEntry 2 }
mwrUserConnectionType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Either telnet, ssh, http or https. Ethernet connection may be through any physical port(s) dedicated to management of the equipment."
::= { mwrUserSessionEntry 3 }
mwrUserConnectionState OBJECT-TYPE
SYNTAX INTEGER {
informationNotAvailable (1),
sessionTerminated (2),
sessionInProgress (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of the session. The session is inProgress if the user is currently logged into the system. The session is terminated if the user has logged out of the system."
::= { mwrUserSessionEntry 4 }
mwrUserSession NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrUserName,
mwrUserConnectionType,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when a change in the state of user access is recognized, a new user has logged in or an existing user has logged out."
::= { mwrUserNotifications 1 }
mwrUserLoginFailed NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrUserName,
mwrUserConnectionType,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when a user has failed to login."
::= { mwrUserNotifications 2 }
mwrUserAccountChanged NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrUserName,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when a change in user account information in the system is detected."
::= { mwrUserNotifications 3 }
mwrUserPasswordChanged NOTIFICATION-TYPE
OBJECTS { mwrEventConfigSeverity,
mwrUserName,
equipmentAlarmActiveConditionId,
equipmentTrapInfo,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"This notification is raised when a user password has changed."
::= { mwrUserNotifications 4 }
END