mibs/MIBS/eltexmes21xx/RADLAN-DEVICEPARAMS-MIB
2023-12-05 12:25:34 +01:00

778 lines
22 KiB
Plaintext

RADLAN-DEVICEPARAMS-MIB DEFINITIONS ::= BEGIN
-- Title: RADLAN ROS
-- Private DEVICE PARAMETERS MIB
-- Version: 7.46
-- Date: 15-Jan-2007
IMPORTS
rnd FROM RADLAN-MIB
OBJECT-TYPE, MODULE-IDENTITY, IpAddress FROM SNMPv2-SMI
TruthValue, DisplayString, PhysAddress FROM SNMPv2-TC;
rndDeviceParams MODULE-IDENTITY
LAST-UPDATED "200701020000Z"
ORGANIZATION "Radlan - a MARVELL company.
Marvell Semiconductor, Inc."
CONTACT-INFO
"www.marvell.com"
DESCRIPTION
"This private MIB module defines general Parameters private MIBs."
REVISION "200701020000Z"
DESCRIPTION
"Initial revision."
::= { rnd 2 }
-- rndDeviceParams group contains a number of general variables
rndBridgeType OBJECT-TYPE
SYNTAX INTEGER {
reb(1),
ceb(2),
ceblb(3),
xeb(4),
xeb1(5),
rebsx(6),
rtb(7),
ltb(8),
tre(9),
rtre(10), -- remote TRE
xtb(11),
ete(12),
rete(13), -- remote ETE
ielb(30),
leb(31),
openGate12(32),
openGate4(33),
ran(34),
itlb(35),
gatelinx(36),
openGate2(37),
ogRanTR(38),
rdapter(39),
ogVan(40),
wanGate(41),
ogRubE(42),
ogRubT(43),
wanGateI(44),
vGate4(45),
lre(46),
mrt(47),
vGate2(48)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification of the RND bridge type."
::= { rndDeviceParams 1 }
rndInactiveArpTimeOut OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the maximum time period that can pass
between ARP requests concerning an entry in the ARP table.
After this time period, the entry is deleted from the table."
::= { rndDeviceParams 2 }
-- The following two variables define the format of RND specific
-- error messages issued by the RND devices
rndBridgeAlarm OBJECT IDENTIFIER ::= { rndDeviceParams 3 }
rndErrorDesc OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual description of the enterprise-specific trap sent
to the Network Management Station by the RND managed device."
::= { rndBridgeAlarm 1 }
rndErrorSeverity OBJECT-TYPE
SYNTAX INTEGER {
info(0),
warning(1),
error(2),
fatal-error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity type of the enterprise-specific trap sent to the
Network Management Station by the RND managed device."
::= { rndBridgeAlarm 2 }
rndBrgVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The bridge version."
::= { rndDeviceParams 4 }
rndBrgFeatures OBJECT-TYPE
SYNTAX OCTET STRING -- SIZE 20
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit mask that defines the features supported by a particular configuration
of this network element:
__________________________________________
| Byte 1|Byte 2 |Byte 3 | ....|Byte 20 |
|87654321| | 87654321|
|________|_______________________________|
Byte1 :
bit1: TX Block mask
bit2: Source Routing Encapulation
bit3: SNA/SDLC
bit4: Frame Relay
bit5: SNMP
bit6: LAN Manager
bit7: High Performance
bit8: Translation
Byte2 :
bit1: DEC Router
bit2: IPX Router
bit3: IP Router
Byte3 :
bit1: Dial Up Backup
bit2: COD
bit3: FACS
bit4: Load Balance
bit5: Remote Configuration
bit6: RIP 2
bit7: OSPF
bit8: IPX RIP/SAP Filter
Byte4 :
bit1: BootP Server
bit2: BootP Client
bit3: Compression
bit4: V25.bis
bit5: ISDN
bit6: CODv2
bit7: NSPF
bit8: UDP Relay
Byte5
bit1:VirtualLAN
bit2:Static IP Multicast
bit3:IP Redundancy
bit4:CCM2
bit5:ISDN Bonding
bit6:Backup Link Selection -- for the VAN/Rdapter ver 4.0
bit7:IP/IPX Forwarding -- for the WANgate ver 4.0
bit8:Improved COD
Byte6
bit1: Server Disptacher
bit2: ISDN_US -- for the VANSX/WANGATE ver 5.0
bit3: PPP
bit4: IP Rip Filter -- for Vgate3
bit5: Zero Hop Routing -- for Vgate3
bit6: ISDN Japan
bit7: PPP-Security
Byte7
bit1: With unmanaged Switch
bit2: 2 LANs
bit3: OSPF Ver 2.0
bit4: FACS Ver 2.0
bit5: Multiple WEB Farm
bit6: Backup Server
bit7: Check Connectivity
bit8: WSD multiplexing
Byte8
bit1: MRT3
bit2: WSD Redundancy
bit3: DHCP Server
bit4: WSD Connection Limit
bit5: WSD Distributed System
bit6: WSD Load Report
bit7: WSD super farm
bit8: RadWiz leased line
Byte9
bit1: PPP IP address negotiaton
bit2: DNS
bit3: Nat
bit4: WSD Static proximity
bit5: WSD Dynamic proximity
bit6: WSD Proxy
bit7: WSD Proximity client
bit8: MAC Load balancing
Byte10
bit1: Unnum Inf
bit2: Power Supply redundancy
bit3: MRT PPP Compression
bit4: ZHR Apolo
bit5: Copy port
bit6: UDP Relay 2.0
bit7: NVRAM
bit8: URL table
Byte11
bit1: URL super farm
bit2: NAT on LAN
bit3: Remote Con
bit4: AP5000
bit5: Session tracking
bit6: Mirroring
bit7: Alias IP
bit8: CSD Nat
Byte12
bit1: content check
bit2: mlb virtual ip
bit3: reserved RadLan
bit4: csd nat exception
bit5: statistics monitor
bit6: reserved-for-radware "
::= { rndDeviceParams 5 }
rndBrgLicense OBJECT-TYPE
SYNTAX OCTET STRING -- SIZE 20
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used for entering a s/w license number for a device.
A separate license number is supplied for each device."
::= { rndDeviceParams 6 }
-- IP Host Parameters
--All the new parameters under this section will be added to the
-- rndMng group, as rndIpHost sub-group.
--
rndIpHost OBJECT IDENTIFIER ::= { rndDeviceParams 7 }
--
--ICMP Transmission Enable\Disable
--The new variable will be
-- Obsolete
-- rndICMPTransmitionEnable OBJECT-TYPE
-- SYNTAX INTEGER {
-- enable(1),
-- disable(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "This variable controlls the ability to transmit ICMP frames"
-- ::= { rndIpHost 1 }
rndCommunityTable OBJECT-TYPE
SYNTAX SEQUENCE OF RndCommunityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The community table of the agent"
::= { rndIpHost 2 }
rndCommunityEntry OBJECT-TYPE
SYNTAX RndCommunityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The row definition for this table."
INDEX { rndCommunityMngStationAddr,
IMPLIED rndCommunityString }
::= { rndCommunityTable 1 }
RndCommunityEntry ::= SEQUENCE {
rndCommunityMngStationAddr IpAddress,
rndCommunityString DisplayString,
rndCommunityAccess INTEGER,
rndCommunityTrapsEnable INTEGER,
rndCommunityStatus INTEGER,
rndCommunityPortSecurity INTEGER,
rndCommunityOwner DisplayString,
rndCommunityTrapDestPort INTEGER
}
rndCommunityMngStationAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The management station that will be allowed to
communicate with the agent IP address"
::= { rndCommunityEntry 1 }
rndCommunityString OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The community string with which the management
station will communicate with the agent"
::= { rndCommunityEntry 2 }
rndCommunityAccess OBJECT-TYPE
SYNTAX INTEGER {
readOnly(1),
readWrite(2),
super(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The allowed access to this management station"
::= { rndCommunityEntry 3}
rndCommunityTrapsEnable OBJECT-TYPE
SYNTAX INTEGER {
snmpV1(1),
snmpV2(2),
snmpV3(3),
trapsDisable(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Should the agent send traps to the management station,
and what version is required"
::= { rndCommunityEntry 4 }
rndCommunityStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
invalid(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this entry. If the status is invalid the
community entry will be deleted"
::= { rndCommunityEntry 5 }
rndCommunityPortSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If enabled the device will only receive SNMP messages from the port,
through which this NMS is reachable from the device."
DEFVAL { disabled }
::= { rndCommunityEntry 6 }
rndCommunityOwner OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The owner of this community"
::= { rndCommunityEntry 7 }
rndCommunityTrapDestPort OBJECT-TYPE
SYNTAX INTEGER(0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The transport protocol (usually UDP) port to which traps to the
management station represebted by this entry will be sent. The default
is the well-known IANA assigned port number for SNMP traps.
This object is relevant only if rndCommunityTrapsEnable has a value
different from trapsDisable."
DEFVAL { 162 }
::= { rndCommunityEntry 8 }
rlMridTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlMridEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MRID related configurations table of the agent"
::= { rndIpHost 3 }
rlMridEntry OBJECT-TYPE
SYNTAX RlMridEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The row definition for this table."
INDEX { rndCommunityMngStationAddr,
IMPLIED rndCommunityString }
::= { rlMridTable 1 }
RlMridEntry ::= SEQUENCE {
rlMridConnection INTEGER,
rlManagedMrid INTEGER
}
rlMridConnection OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The router instance connecting the NMS who accessed the agent
through the community table entry corresponding to the keys of this entry."
::= { rlMridEntry 1 }
rlManagedMrid OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The router instance currently managed by the NMS who accessed the agent
through the community table entry corresponding to the keys of this entry "
::= { rlMridEntry 2 }
rndManagedTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time will be sent in the format hhmmss"
::= { rndDeviceParams 8 }
rndManagedDate OBJECT-TYPE
SYNTAX DisplayString (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The date will be sent in the format ddmmyy"
::= { rndDeviceParams 9 }
rndBaseBootVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the boot version of the product."
::= { rndDeviceParams 10 }
rndIpHostManagement OBJECT IDENTIFIER ::= { rndIpHost 4 }
rndIpHostManagementSupported OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ifindex manage supported."
::= { rndIpHostManagement 1 }
rndIpHostManagementIfIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"if supported manage , indicate ifindex, if 0 thaen disable"
::= { rndIpHostManagement 2 }
genGroup OBJECT IDENTIFIER ::= { rndDeviceParams 11 }
genGroupHWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the HW version of the product."
::= { genGroup 1 }
genGroupConfigurationSymbol OBJECT-TYPE
SYNTAX DisplayString (SIZE(1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the Configuration Symbol attached to any hardware module
manufactured by LANNET. One single character A..Z defines the CS
version."
::= { genGroup 2 }
genGroupHWStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
hardwareProblems(2),
notSupported(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the status of the group hardware as detected
by the sensors software."
::= { genGroup 3 }
rndBasePhysicalAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Base physical (MAC) address of the device."
::= { rndDeviceParams 12 }
RlImageIdType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"SW images enumeration"
SYNTAX INTEGER { image1(1), image2(2) }
rndSoftwareFile OBJECT IDENTIFIER ::= { rndDeviceParams 13 }
rndActiveSoftwareFileTable OBJECT-TYPE
SYNTAX SEQUENCE OF RndActiveSoftwareFileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The (conceptual) table listing the active software file of the
requested unit."
::= {rndSoftwareFile 1 }
rndActiveSoftwareFileEntry OBJECT-TYPE
SYNTAX RndActiveSoftwareFileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry (conceptual row) in the rndActiveSoftwareFileTable."
INDEX {rndUnitNumber }
::= {rndActiveSoftwareFileTable 1 }
RndActiveSoftwareFileEntry ::= SEQUENCE {
rndUnitNumber INTEGER,
rndActiveSoftwareFile RlImageIdType,
rndActiveSoftwareFileAfterReset INTEGER
}
rndUnitNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unit number (for stackable devices) or 1 for 'stand alone' device."
::= {rndActiveSoftwareFileEntry 1 }
rndActiveSoftwareFile OBJECT-TYPE
SYNTAX RlImageIdType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current active software file, image1 or image2."
::= {rndActiveSoftwareFileEntry 2 }
rndActiveSoftwareFileAfterReset OBJECT-TYPE
SYNTAX INTEGER {
image1(1),
image2(2),
invalidImage(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the software file that will be active after reset (image1 or image2).
If an error occurred in the download process, resulting in the corruption
of the single software file, The value 'invalidImage' will be returned.
This value can not be set by the user."
::= {rndActiveSoftwareFileEntry 3 }
rlResetStatus
OBJECT-TYPE
SYNTAX BITS {
ok(0),
no-stack-integrity(1),
downgrade(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit mask that specifies system status before reset action is preformed.
Reset is prohibited in stackable products if the images selected after
reboot are not of the same release version in ALL stack units.
Downgrade status specifies that there are some actions to be preformed
on the CDB file before reset is preformed.
0x0 - OK
0x1 - noStackIntegrity
0x2 - downgrade"
::= { rndSoftwareFile 2 }
rndImageSize OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Max number of sectors currently allocated for image(s)."
::= { rndDeviceParams 14 }
rndBackupConfigurationEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether the device supports backup-config parameters in lcli commands."
::= { rndDeviceParams 15 }
rndImageInfo OBJECT IDENTIFIER ::= { rndDeviceParams 16 }
rndImageInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF RndImageInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The table contains information about images."
::= {rndImageInfo 1 }
rndImageInfoEntry OBJECT-TYPE
SYNTAX RndImageInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the rndImageInfoTable."
INDEX {rndStackUnitNumber }
::= {rndImageInfoTable 1 }
RndImageInfoEntry ::= SEQUENCE {
rndStackUnitNumber INTEGER,
rndImage1Name DisplayString,
rndImage2Name DisplayString,
rndImage1Version DisplayString,
rndImage2Version DisplayString,
rndImage1Date DisplayString,
rndImage2Date DisplayString,
rndImage1Time DisplayString,
rndImage2Time DisplayString
}
rndStackUnitNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The unit number (for stackable devices) or 1 for 'stand alone' device."
::= {rndImageInfoEntry 1 }
rndImage1Name OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the file name of image-1 in the system."
::= {rndImageInfoEntry 2 }
rndImage2Name OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the file name of image-2 (if present) in the system.If image-2 is not present show 'no info' text"
::= {rndImageInfoEntry 3 }
rndImage1Version OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the version of image-1 in the system."
::= {rndImageInfoEntry 4 }
rndImage2Version OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the version of image-2 (if present) in the system.If image-2 is not present show 'no info' text"
::= {rndImageInfoEntry 5 }
rndImage1Date OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the compilation date of image-1 in the system."
::= {rndImageInfoEntry 6 }
rndImage2Date OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the compilation date of image-2 (if present) in the system.If image-2 is not present show 'no info' text"
::= {rndImageInfoEntry 7 }
rndImage1Time OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the compilation time of image-1 in the system."
::= {rndImageInfoEntry 8 }
rndImage2Time OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the compilation time of image-2 (if present) in the system.If image-2 is not present show 'no info' text"
::= {rndImageInfoEntry 9 }
rlComponentsInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlComponentsInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table contains information about components, their streams and baselines in the device images."
::= {rndImageInfo 2}
rlComponentsInfoEntry OBJECT-TYPE
SYNTAX RlComponentsInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the rlComponentsInfoTable."
INDEX {rlComponentsInfoStackUnitNumber, rlComponentsInfoImageId,
IMPLIED rlComponentsInfoComponent}
::= {rlComponentsInfoTable 1 }
RlComponentsInfoEntry ::= SEQUENCE {
rlComponentsInfoStackUnitNumber INTEGER,
rlComponentsInfoImageId RlImageIdType,
rlComponentsInfoComponent DisplayString,
rlComponentsInfoBaseline DisplayString
}
rlComponentsInfoStackUnitNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The unit number (for stackable devices) or 1 for 'stand alone' device."
::= {rlComponentsInfoEntry 1}
rlComponentsInfoImageId OBJECT-TYPE
SYNTAX RlImageIdType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the image id in the unit"
::= {rlComponentsInfoEntry 2}
rlComponentsInfoComponent OBJECT-TYPE
SYNTAX DisplayString(SIZE (1..40))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the SW component name."
::= {rlComponentsInfoEntry 3}
rlComponentsInfoBaseline OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the version control baseline of the SW component name."
::= {rlComponentsInfoEntry 5}