mibs/MIBS/eltexmes21xx/RADLAN-Physicaldescription-MIB
2023-12-05 12:25:34 +01:00

1180 lines
40 KiB
Plaintext

RADLAN-Physicaldescription-MIB DEFINITIONS ::= BEGIN
-- Version: 7.46
-- Date: 15-Jan-2007
--
-- 30-Jan-2004 Add rlPhdUnitGenParamTable
-- 30-Jan-2004 Add rlPhdUnitEnvParamTable
-- 24-Feb-2004 Add rlPhdStackOrderTopUnit
-- 24-Feb-2004 Add rlPhdStackOrderBottomUnit
-- 24-Feb-2004 Add rlPhdStackOrderPermutation
-- 21-Apr-2005 Add rlPhdPortsTable switch description between:
-- rlPhdPortsModuleNumber && rlPhdPortsStackUnit due to EWS need
-- 27-Apr-2005 Add rlStackLinkChange trap.
-- 16-May-2005 Add rlPhdNumberOfPoeUnits
-- 02-Jun-2005 Add field to rlPhDUnitEnvParamTable: rlPhdUnitEnvParamUpTime
-- 25-Jul-2005 Add rlPhdPhyLedTimeout and rlPhdPhyLedStackUnit
-- 03-Aug-2005 Remove boundary for unit number field, checked by box
-- this is done coz different products use different stack size
-- 05-Sep-2005 Add rlCascadeTable
-- 31-Oct-2005 Add rlCascadeAfterResetTable
-- 14-Nov-2005 Change rlPhdUnitGenParamSerialNum to read-write
-- 16-May-2006 Add field rlCascadeUnitId to rlCascadeEntry
-- 14-Jan-2007 rlPhdModuleType was moved to a separated text file
-- 15-Jan-2007 Devided file appolo.txt to a few files
-- Renamed file appolo.txt to ralan-mib.mib
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, TimeTicks,
NOTIFICATION-TYPE FROM SNMPv2-SMI
DisplayString, PhysAddress, RowStatus FROM SNMPv2-TC
JackType FROM MAU-MIB
rnd, rndNotifications FROM RADLAN-MIB
RlEnvMonState FROM RADLAN-HWENVIROMENT
EntitySensorStatus, EntitySensorValue FROM ENTITY-SENSOR-MIB
InterfaceIndexOrZero,ifIndex,InterfaceIndex FROM IF-MIB
rndErrorDesc, rndErrorSeverity FROM RADLAN-DEVICEPARAMS-MIB;
rlPhysicalDescription MODULE-IDENTITY
LAST-UPDATED "200602120000Z"
ORGANIZATION "Radlan Computer Communications Ltd."
CONTACT-INFO
"radlan.com"
DESCRIPTION
"The private MIB module definition for physical
device configuration."
REVISION "200602120000Z"
DESCRIPTION
"Removed TRAP-TYPE from IMPORTS."
REVISION "200310180000Z"
DESCRIPTION
"Initial version of this MIB."
::= { rnd 53 }
rlPhdMibVersion OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MIB's version, the current version is 3.
1: original version
2: a. new tables
rlPhdModuleHotSwapTable
rlPhdStackOrderTable
b. new scalars
rlPhdStackReorder
rlPhdNumberOfUnits
rlPhdMaxNumberOfUnits
3: a. new field rlPhdModuleRole of rlPhdModuleTable
b. new scalars
rlPhdForceMasterUnit
4: a. new fields rlPhdModuleConnect1 and rlPhdModuleConnect2
of rlPhdModuleTable.
5: a. Prefix rlPhD were replaced by prefix rlPhd
b. fields rlPhdModuleConnect1 and rlPhdModuleConnect2 are
moved from rlPhdModuleTable to rlPhdStackTable.
c. new fiels rlPhdStackSofrwareVer, rlPhdStackProductID and
rlPhdStackMacAddr of rlPhdStackTable.
d. new scalars
rlPhdStackReloadUnit
e. new scalars
rlPhdStackOrderTopUnit
rlPhdStackOrderBottomUnit
rlPhdStackOrderPermutation"
::= { rlPhysicalDescription 1 }
rlPhdModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPhdModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each module (board) there is an entry describing it in this
module"
::= { rlPhysicalDescription 2 }
rlPhdModuleEntry OBJECT-TYPE
SYNTAX RlPhdModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A entry of this table specifies a module (board)"
INDEX { rlPhdModuleStackUnit, rlPhdModuleIndex}
::= { rlPhdModuleTable 1 }
RlPhdModuleEntry ::= SEQUENCE {
rlPhdModuleStackUnit INTEGER,
rlPhdModuleIndex INTEGER,
rlPhdModuleType INTEGER,
rlPhdModuleStartingPort INTEGER,
rlPhdModuleNumberOfPorts INTEGER,
rlPhdModuleRow INTEGER,
rlPhdModuleColumn INTEGER,
rlPhdModuleRole INTEGER
}
rlPhdModuleStackUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the stack unit"
::= { rlPhdModuleEntry 1 }
rlPhdModuleIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the module in its stack unit"
::= { rlPhdModuleEntry 2 }
rlPhdModuleType OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index for each module type"
::= { rlPhdModuleEntry 3 }
rlPhdModuleStartingPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimal number of the port residing on this module."
::= { rlPhdModuleEntry 4 }
rlPhdModuleNumberOfPorts OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ports residing on this module."
::= { rlPhdModuleEntry 5}
rlPhdModuleRow OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"On which row (the uppermost being numbered 1 and the highest row
number asigned to the lowest row) this module resides within the
chassis of its stack unit."
::= { rlPhdModuleEntry 6 }
rlPhdModuleColumn OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"On which column (the leftmost being numbered 1 and the highest column
number asigned to the rightmost column) this module resides within the
chassis of its stack unit."
::= { rlPhdModuleEntry 7 }
rlPhdModuleRole OBJECT-TYPE
SYNTAX INTEGER {
standalone(1),
master(2),
backup(3),
slave(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module role in the stack."
DEFVAL { standalone }
::= { rlPhdModuleEntry 8 }
rlPhdPortsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPhdPortsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Lists the physical or physical-related attributes of ports"
::= { rlPhysicalDescription 3 }
rlPhdPortsEntry OBJECT-TYPE
SYNTAX RlPhdPortsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each port, a entry describing attributes which are either
physical or are derived from the features of the device hardware"
INDEX { rlPhdPortsIfIndex }
::= { rlPhdPortsTable 1 }
RlPhdPortsEntry ::= SEQUENCE {
rlPhdPortsIfIndex INTEGER,
rlPhdPortsIfIndexName DisplayString(SIZE(1..20)),
rlPhdPortsMediaType INTEGER,
rlPhdPortsStackUnit INTEGER,
rlPhdPortsModuleNumber INTEGER,
rlPhdPortsRow INTEGER,
rlPhdPortsColumn INTEGER,
rlPhdConnectorType JackType,
rlPhdPortHaul INTEGER
}
rlPhdPortsIfIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The L2 interface number associated with this port."
::= { rlPhdPortsEntry 1 }
rlPhdPortsIfIndexName OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The L2 interface number associated with this port, in string format
based on the overall hardware architecture of the device (i.e., for
monolithic devices just numbers, devices composed of modules (boards,
cards) or stackable devices composed of monolithic units in form
<module /stack unit number> - <port number on current module /stack
unit number>, stackable devices in which each unit is composed of
modules
<stack unit number> - <module number> - <port number>"
::= { rlPhdPortsEntry 2 }
rlPhdPortsMediaType OBJECT-TYPE
SYNTAX INTEGER {copper(1), optic-fiber(2), combo(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The media type of this port."
::= { rlPhdPortsEntry 3 }
rlPhdPortsStackUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the slot to which this port belongs."
::= { rlPhdPortsEntry 4 }
rlPhdPortsModuleNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the stack unit to which this port resides in."
::= { rlPhdPortsEntry 5 }
rlPhdPortsRow OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"On which row (the uppermost being numbered 1 and the highest row
number asigned to the lowest row) this port resides within its
module."
::= { rlPhdPortsEntry 6 }
rlPhdPortsColumn OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"On which column (the leftmost being numbered 1 and the highest column
number asigned to the rightmost column) this this port resides within its
module."
::= { rlPhdPortsEntry 7 }
rlPhdConnectorType OBJECT-TYPE
SYNTAX JackType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of connector."
::= { rlPhdPortsEntry 8 }
rlPhdPortHaul OBJECT-TYPE
SYNTAX INTEGER {
not-relevant(1),
short(2),
long(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Distance supported by this port."
::= { rlPhdPortsEntry 9 }
rlPhdStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPhdStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each stack unit there is an entry describing it in this table"
::= { rlPhysicalDescription 4 }
rlPhdStackEntry OBJECT-TYPE
SYNTAX RlPhdStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A entry of this table specifies a stack unit"
INDEX { rlPhdStackUnit }
::= { rlPhdStackTable 1 }
RlPhdStackEntry ::= SEQUENCE {
rlPhdStackUnit INTEGER,
rlPhdStackType INTEGER,
rlPhdStackConnect1 INTEGER,
rlPhdStackConnect2 INTEGER,
rlPhdStackSofrwareVer DisplayString,
rlPhdStackProductID DisplayString,
rlPhdStackMacAddr PhysAddress
}
rlPhdStackUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The stack unit described by this entry."
::= { rlPhdStackEntry 1 }
rlPhdStackType OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the stack unit described by this entry:
1 - box 3202
2 - box LG
3 - bcm
4 - prestera"
::= { rlPhdStackEntry 2 }
rlPhdStackConnect1 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit number connected to the Hyper GLink left side connection -
0 means not connected; other integer indicates the unit number."
DEFVAL { 0 }
::= { rlPhdStackEntry 3 }
rlPhdStackConnect2 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit number connected to the Hyper GLink right side connection -
0 means not connected; other integer indicates the unit number."
DEFVAL { 0 }
::= { rlPhdStackEntry 4 }
rlPhdStackSofrwareVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Software version of the unit."
::= { rlPhdStackEntry 5 }
rlPhdStackProductID OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Product ID of the unit."
::= { rlPhdStackEntry 6 }
rlPhdStackMacAddr OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical (MAC) address of the unit."
::= { rlPhdStackEntry 7 }
rlPhdModuleHotSwapTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPhdModuleHotSwapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each module (board) there is an entry describing its Hot Swap
status"
::= { rlPhysicalDescription 5 }
rlPhdModuleHotSwapEntry OBJECT-TYPE
SYNTAX RlPhdModuleHotSwapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A entry of this table specifies a module (board) Hot Swap
status"
INDEX { rlPhdModuleStackUnit, rlPhdModuleIndex}
::= { rlPhdModuleHotSwapTable 1 }
RlPhdModuleHotSwapEntry ::= SEQUENCE {
rlPhdModuleHotSwapAdminStatus INTEGER,
rlPhdModuleHotSwapOperStatus INTEGER
}
rlPhdModuleHotSwapAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired state of the module. The off(1) state indicates
that the module is not used and its rlPhdModuleHotSwapOperStatus
is always off(2).
The on{1) state indicates that the module may be used and its
rlPhdModuleHotSwapOperStatus will be on(1) if it presents and
off(2) if it does not present."
DEFVAL { on }
::= { rlPhdModuleHotSwapEntry 1 }
rlPhdModuleHotSwapOperStatus OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Hot Swap state of the module.
If rlPhdModuleHotSwapAdminStatus is down(2) then
rlPhdModuleHotSwapOperStatus should be down(2). If
rlPhdModuleHotSwapAdminStatus is changed to up(1) then
rlPhdModuleHotSwapOperStatus should change to
up(1) if the module presents; it should remain in the down(2) state if
and only if the module does not present."
::= { rlPhdModuleHotSwapEntry 2 }
rlPhdStackOrderTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPhdStackOrderEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table enables the user to configure the order
of the stack units as displayed on his GUI.
The order of the entries in this table corresponds
to the last configured order. If the stack units order was
never configured, the order will be the same as in the rlPhdStackTable."
::= { rlPhysicalDescription 6 }
rlPhdStackOrderEntry OBJECT-TYPE
SYNTAX RlPhdStackOrderEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A entry of this table specifies a stack unit in the position desired by the user"
INDEX { rlPhdStackOrderCurrentUnitPosition }
::= { rlPhdStackOrderTable 1 }
RlPhdStackOrderEntry ::= SEQUENCE {
rlPhdStackOrderCurrentUnitPosition INTEGER,
rlPhdStackOrderDesiredUnitPosition INTEGER,
rlPhdStackOrderUnitIndex INTEGER,
rlPhdStackOrderUnitType INTEGER
}
rlPhdStackOrderCurrentUnitPosition OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The current stack unit position."
::= { rlPhdStackOrderEntry 1 }
rlPhdStackOrderDesiredUnitPosition OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired stack unit position. Note that setting this MIB
object will take effect only after setting the rlPhdStackReorder MIB
object below. After setting this MIB object and until a further change
of at least one instance of the rlPhdStackOrderDesiredUnitPosition object,
the values of the rlPhdStackOrderCurrentUnitPosition objectinstance and
the corresponding rlPhdStackOrderDesiredUnitPosition object instance
will be the same."
::= { rlPhdStackOrderEntry 2 }
rlPhdStackOrderUnitIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the original unit index, i.e. has the same value as rlPhdStackUnit
above."
::= { rlPhdStackOrderEntry 3 }
rlPhdStackOrderUnitType OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the stack unit described by this entry. It has the same value
as rlPhdStackType above. This information is duplicated here only for easier
retrieval by the device manager."
::= { rlPhdStackOrderEntry 4 }
rlPhdStackReorder OBJECT-TYPE
SYNTAX INTEGER {reorder(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this MIB object will cause the settings of the
rlPhdStackOrderDesiredUnitPosition MIB object instances to take effect.
After setting this MIB object and until a further change
of at least one instance of the rlPhdStackOrderDesiredUnitPosition object,
the values of the rlPhdStackOrderCurrentUnitPosition objectinstance and
the corresponding rlPhdStackOrderDesiredUnitPosition object instance
will be the same."
::= { rlPhysicalDescription 7 }
rlPhdNumberOfUnits OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the current number of units in the stack."
::= { rlPhysicalDescription 8 }
rlPhdMaxNumberOfUnits OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the maximum number of units in the stack."
::= { rlPhysicalDescription 9 }
rlPhdForceMasterUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Force unit to be master."
::= { rlPhysicalDescription 10 }
-- The following scalar isn't suported and will be removed
rlPhdStackFixedUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determine which unit will be on bottom/top of list
on Show-List command(see ."
::= { rlPhysicalDescription 11 }
-- The following scalar isn't suported and will be removed
rlPhdStackFixedUnitLocation OBJECT-TYPE
SYNTAX INTEGER{
bottom(1),
top(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determine the bottom/top object in the stack table."
::= { rlPhysicalDescription 12 }
rlPhdStackReloadUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset a specific unit."
::= { rlPhysicalDescription 13 }
rlPhdUnitGenParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPhdUnitGenParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each module (board) there is an entry describing it in this
module"
::= { rlPhysicalDescription 14 }
rlPhdUnitGenParamEntry OBJECT-TYPE
SYNTAX RlPhdUnitGenParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A entry of this table specifies a module (board)"
INDEX { rlPhdUnitGenParamStackUnit}
::= { rlPhdUnitGenParamTable 1 }
RlPhdUnitGenParamEntry ::= SEQUENCE {
rlPhdUnitGenParamStackUnit INTEGER,
rlPhdUnitGenParamSoftwareVersion DisplayString,
rlPhdUnitGenParamFirmwareVersion DisplayString,
rlPhdUnitGenParamHardwareVersion DisplayString,
rlPhdUnitGenParamSerialNum DisplayString,
rlPhdUnitGenParamAssetTag DisplayString,
rlPhdUnitGenParamServiceTag DisplayString,
rlPhdUnitGenParamSoftwareDate DisplayString,
rlPhdUnitGenParamFirmwareDate DisplayString,
rlPhdUnitGenParamManufacturer DisplayString,
rlPhdUnitGenParamModelName DisplayString,
rlPhdUnitGenParamMd5ChksumBoot DisplayString,
rlPhdUnitGenParamMd5ChksumImage1 DisplayString,
rlPhdUnitGenParamMd5ChksumImage2 DisplayString
}
rlPhdUnitGenParamStackUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the stack unit to which this conceptual row corresponds.
Note that the index will be the same index as the index
of a 'chassis' physical entity in the entity MIB of the product."
::= { rlPhdUnitGenParamEntry 1 }
rlPhdUnitGenParamSoftwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial number of the product."
::= { rlPhdUnitGenParamEntry 2 }
rlPhdUnitGenParamFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial number of the product."
::= { rlPhdUnitGenParamEntry 3 }
rlPhdUnitGenParamHardwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial number of the product."
::= { rlPhdUnitGenParamEntry 4 }
rlPhdUnitGenParamSerialNum OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Serial number of the product."
::= { rlPhdUnitGenParamEntry 5 }
rlPhdUnitGenParamAssetTag OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Serial number of the product."
::= { rlPhdUnitGenParamEntry 6 }
rlPhdUnitGenParamServiceTag OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Asset tag of the product."
::= { rlPhdUnitGenParamEntry 7 }
rlPhdUnitGenParamSoftwareDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Date of product's software."
::= { rlPhdUnitGenParamEntry 8 }
rlPhdUnitGenParamFirmwareDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Date of product's firmware."
::= { rlPhdUnitGenParamEntry 9 }
rlPhdUnitGenParamManufacturer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Product's Manufacturer."
::= { rlPhdUnitGenParamEntry 10 }
rlPhdUnitGenParamModelName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Model Name."
::= { rlPhdUnitGenParamEntry 11 }
rlPhdUnitGenParamMd5ChksumBoot OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MD5 Checksum for Boot"
::= { rlPhdUnitGenParamEntry 12 }
rlPhdUnitGenParamMd5ChksumImage1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MD5 Checksum for Image 1"
::= { rlPhdUnitGenParamEntry 13 }
rlPhdUnitGenParamMd5ChksumImage2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MD5 Checksum for Image 2"
::= { rlPhdUnitGenParamEntry 14 }
rlPhdUnitEnvParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPhdUnitEnvParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each module (board) there is an entry describing it in this
module"
::= { rlPhysicalDescription 15 }
rlPhdUnitEnvParamEntry OBJECT-TYPE
SYNTAX RlPhdUnitEnvParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A entry of this table specifies a module (board)"
INDEX { rlPhdUnitEnvParamStackUnit}
::= { rlPhdUnitEnvParamTable 1 }
RlPhdUnitEnvParamEntry ::= SEQUENCE {
rlPhdUnitEnvParamStackUnit INTEGER,
rlPhdUnitEnvParamMainPSStatus RlEnvMonState,
rlPhdUnitEnvParamRedundantPSStatus RlEnvMonState,
rlPhdUnitEnvParamFan1Status RlEnvMonState,
rlPhdUnitEnvParamFan2Status RlEnvMonState,
rlPhdUnitEnvParamFan3Status RlEnvMonState,
rlPhdUnitEnvParamFan4Status RlEnvMonState,
rlPhdUnitEnvParamFan5Status RlEnvMonState,
rlPhdUnitEnvParamTempSensorValue EntitySensorValue,
rlPhdUnitEnvParamTempSensorStatus EntitySensorStatus,
rlPhdUnitEnvParamUpTime TimeTicks,
rlPhdUnitEnvParamTempSensor2Value EntitySensorValue,
rlPhdUnitEnvParamTempSensor2Status EntitySensorStatus,
rlPhdUnitEnvParamTempSensor3Value EntitySensorValue,
rlPhdUnitEnvParamTempSensor3Status EntitySensorStatus,
rlPhdUnitEnvParamTempSensor4Value EntitySensorValue,
rlPhdUnitEnvParamTempSensor4Status EntitySensorStatus,
rlPhdUnitEnvParamTempSensor5Value EntitySensorValue,
rlPhdUnitEnvParamTempSensor5Status EntitySensorStatus
}
rlPhdUnitEnvParamStackUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the stack unit to which this conceptual row corresponds.
Note that the index will be the same index as the index
of a 'chassis' physical entity in the entity MIB of the product."
::= { rlPhdUnitEnvParamEntry 1 }
rlPhdUnitEnvParamMainPSStatus OBJECT-TYPE
SYNTAX RlEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the main PS being instrumented."
::= { rlPhdUnitEnvParamEntry 2 }
rlPhdUnitEnvParamRedundantPSStatus OBJECT-TYPE
SYNTAX RlEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the redundant PS being instrumented."
::= { rlPhdUnitEnvParamEntry 3 }
rlPhdUnitEnvParamFan1Status OBJECT-TYPE
SYNTAX RlEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the FAN 1 being instrumented."
::= { rlPhdUnitEnvParamEntry 4 }
rlPhdUnitEnvParamFan2Status OBJECT-TYPE
SYNTAX RlEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the FAN 2 being instrumented."
::= { rlPhdUnitEnvParamEntry 5 }
rlPhdUnitEnvParamFan3Status OBJECT-TYPE
SYNTAX RlEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the FAN 3 being instrumented."
::= { rlPhdUnitEnvParamEntry 6 }
rlPhdUnitEnvParamFan4Status OBJECT-TYPE
SYNTAX RlEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the FAN 4 being instrumented."
::= { rlPhdUnitEnvParamEntry 7 }
rlPhdUnitEnvParamFan5Status OBJECT-TYPE
SYNTAX RlEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the FAN 5 being instrumented."
::= { rlPhdUnitEnvParamEntry 8 }
rlPhdUnitEnvParamTempSensorValue OBJECT-TYPE
SYNTAX EntitySensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current value for the Sensor being instrumented."
::= { rlPhdUnitEnvParamEntry 9 }
rlPhdUnitEnvParamTempSensorStatus OBJECT-TYPE
SYNTAX EntitySensorStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status value for the Sensor being instrumented."
::= { rlPhdUnitEnvParamEntry 10 }
rlPhdUnitEnvParamUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Up time of the unit in 100th of second (sec/100)."
::= { rlPhdUnitEnvParamEntry 11 }
rlPhdUnitEnvParamTempSensor2Value OBJECT-TYPE
SYNTAX EntitySensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current value for the Sensor2 being instrumented."
::= { rlPhdUnitEnvParamEntry 12 }
rlPhdUnitEnvParamTempSensor2Status OBJECT-TYPE
SYNTAX EntitySensorStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status value for the Sensor2 being instrumented."
::= { rlPhdUnitEnvParamEntry 13 }
rlPhdUnitEnvParamTempSensor3Value OBJECT-TYPE
SYNTAX EntitySensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current value for the Sensor3 being instrumented."
::= { rlPhdUnitEnvParamEntry 14 }
rlPhdUnitEnvParamTempSensor3Status OBJECT-TYPE
SYNTAX EntitySensorStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status value for the Sensor3 being instrumented."
::= { rlPhdUnitEnvParamEntry 15 }
rlPhdUnitEnvParamTempSensor4Value OBJECT-TYPE
SYNTAX EntitySensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current value for the Sensor4 being instrumented."
::= { rlPhdUnitEnvParamEntry 16 }
rlPhdUnitEnvParamTempSensor4Status OBJECT-TYPE
SYNTAX EntitySensorStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status value for the Sensor4 being instrumented."
::= { rlPhdUnitEnvParamEntry 17 }
rlPhdUnitEnvParamTempSensor5Value OBJECT-TYPE
SYNTAX EntitySensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current value for the Sensor5 being instrumented."
::= { rlPhdUnitEnvParamEntry 18 }
rlPhdUnitEnvParamTempSensor5Status OBJECT-TYPE
SYNTAX EntitySensorStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status value for the Sensor5 being instrumented."
::= { rlPhdUnitEnvParamEntry 19 }
rlPhdStackOrderTopUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This scalar mib holds the Top unit for the stack order command"
::= { rlPhysicalDescription 16 }
rlPhdStackOrderBottomUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This scalar mib holds the Bottom unit for the stack order command"
::= { rlPhysicalDescription 17 }
rlPhdStackOrderPermutation OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This scalar mib holds stack permutation"
::= { rlPhysicalDescription 18 }
rlPhdNumberOfPoeUnits OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the current number of poe units in the stack."
::= { rlPhysicalDescription 19 }
rlPhdPoeTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPhdPoeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each module (board) there is an entry describing it in this
module"
::= { rlPhysicalDescription 20 }
rlPhdPoeEntry OBJECT-TYPE
SYNTAX RlPhdPoeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A entry of this table specifies a module (board)"
INDEX { rlPhdPoeStackUnit }
::= { rlPhdPoeTable 1 }
RlPhdPoeEntry ::= SEQUENCE {
rlPhdPoeStackUnit INTEGER,
rlPhdPoePresent INTEGER
}
rlPhdPoeStackUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The stack unit to which this module belongs."
::= { rlPhdPoeEntry 1 }
rlPhdPoePresent OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The present state of the PoE module. The no(1) state indicates
that the PoE module is not present. The yes{2) state indicates that the
PoE module is present."
::= { rlPhdPoeEntry 2 }
-- The light unit scalars
rlPhdPhyLedStackUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This scalar mib holds the unit number for the stack light command"
::= { rlPhysicalDescription 21 }
rlPhdPhyLedTimeout OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This scalar mib holds the timeout for the stack light command.
May be in the range 2..60 sec. (default - 5 sec.), if the timeout = 0
- all units return to normal state."
::= { rlPhysicalDescription 22 }
rlCascadeTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlCascadeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each cascaded port for stacking unit there is an entry describing it in this table"
::= { rlPhysicalDescription 23 }
rlCascadeEntry OBJECT-TYPE
SYNTAX RlCascadeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of this table specifies a cascaded link information in a unit"
INDEX { ifIndex }
::= { rlCascadeTable 1 }
RlCascadeEntry ::= SEQUENCE {
rlCascadeNeighborIfIndex InterfaceIndexOrZero,
rlCascadeNeighborUnit INTEGER,
rlCascadeTrunkId INTEGER,
rlCascadeUnitId INTEGER
}
rlCascadeNeighborIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex of a stacking port in the neighbor unit -
0 means not connected; other integer indicates the IfIndex."
::= { rlCascadeEntry 1 }
rlCascadeNeighborUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit number of the neighbor unit -
0 means not connected; other integer indicates the unit number."
::= { rlCascadeEntry 2 }
rlCascadeTrunkId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The id of the trunk, the stacking port is member,
zero if the port is not member of trunk."
::= { rlCascadeEntry 3 }
rlCascadeUnitId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit number matching the current ifIndex"
::= { rlCascadeEntry 4 }
rlCascadeAfterResetTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlCascadeAfterResetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each cascaded port for stacking unit there is an entry describing it in this table after reset"
::= { rlPhysicalDescription 24 }
rlCascadeAfterResetEntry OBJECT-TYPE
SYNTAX RlCascadeAfterResetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A entry of this table specifies a cascaded port information in a unit after reset"
INDEX { rlCascadeIfIndexAfterReset }
::= { rlCascadeAfterResetTable 1 }
RlCascadeAfterResetEntry ::= SEQUENCE {
rlCascadeIfIndexAfterReset InterfaceIndex,
rlCascadeTrunkIdAfterReset INTEGER,
rlCascadeRowStatus RowStatus
}
rlCascadeIfIndexAfterReset OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex of a stacking port after reset."
::= { rlCascadeAfterResetEntry 1 }
rlCascadeTrunkIdAfterReset OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Id of the trunk, the stacking port will be member after reset,
zero if the port is not member of trunk."
::= { rlCascadeAfterResetEntry 2 }
rlCascadeRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object indicates the status of this entry."
::= { rlCascadeAfterResetEntry 3 }
-- Stack MIB Trap Definitions
rlStackUnitRemoved NOTIFICATION-TYPE
OBJECTS { rndErrorDesc, rndErrorSeverity }
STATUS current
DESCRIPTION
"Trap indicating that a unit was removed from the stack."
::= { rndNotifications 186 }
rlStackConfigChangedRingChain NOTIFICATION-TYPE
OBJECTS { rndErrorDesc, rndErrorSeverity }
STATUS current
DESCRIPTION
"Trap indicating that the configuration of the stack has changed.
- from ring to chain
- from chain to ring."
::= { rndNotifications 187 }
rlStackBackupUnitRemoved NOTIFICATION-TYPE
OBJECTS { rndErrorDesc, rndErrorSeverity }
STATUS current
DESCRIPTION
"Trap indicating that the backup unit was removed from the stack."
::= { rndNotifications 188 }
rlStackMasterSwitchover NOTIFICATION-TYPE
OBJECTS { rndErrorDesc, rndErrorSeverity }
STATUS current
DESCRIPTION
"Trap indicating that a new master was elected.
The old maste is the backup now. "
::= { rndNotifications 189 }
rlStackUnitDifferentSwVersion NOTIFICATION-TYPE
OBJECTS { rndErrorDesc, rndErrorSeverity }
STATUS current
DESCRIPTION
"Trap indicating that the new unit added to the stack has
different software version than the master."
::= { rndNotifications 190 }
rlStackDuplicateUnitNotJoin NOTIFICATION-TYPE
OBJECTS { rndErrorDesc, rndErrorSeverity }
STATUS current
DESCRIPTION
"Trap indicating that a new unit with duplicated unit id was
added to the stack - but it will not join the stack."
::= { rndNotifications 191 }
rlStackLinkChange NOTIFICATION-TYPE
OBJECTS { rndErrorDesc, rndErrorSeverity }
STATUS current
DESCRIPTION
"Trap indicating that Link has change in one of the Stacking Ports."
::= { rndNotifications 195 }
END