mibs/MIBS/eltexmes23xx/RADLAN-HWENVIROMENT
2023-12-05 12:25:34 +01:00

474 lines
16 KiB
Plaintext

RADLAN-HWENVIROMENT DEFINITIONS ::= BEGIN
IMPORTS
rnd FROM RADLAN-MIB
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32 FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString,TruthValue FROM SNMPv2-TC;
rlEnv MODULE-IDENTITY
LAST-UPDATED "200309210000Z"
ORGANIZATION "Radlan Computer Communications Ltd."
CONTACT-INFO
"radlan.com"
DESCRIPTION
"The private MIB module definition for environment of Radlan devices."
REVISION "200309210000Z"
DESCRIPTION
"Added this MODULE-IDENTITY clause."
::= { rnd 83 }
RlEnvMonState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents the state of a device being monitored.
Valid values are:
normal(1): the environment is good, such as low
temperature or full battery charge.
warning(2): the environment is bad, such as temperature
above normal operation range but not too
high, or battery discharge.
critical(3): the environment is very bad, such as
temperature much higher than normal
operation limit or critically low battery charge.
shutdown(4): the environment is the worst, the system
should be shutdown immediately.
notPresent(5): the environmental monitor is not present,
such as temperature sensors or battery does not exist.
notFunctioning(6): the environmental monitor does not
function properly, such as a temperature
sensor generates a abnormal data like
1000 or error happens while reading battery
state.
restore(7): the environment is restoring its normal state,
such as battery recharging.
"
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3),
shutdown(4),
notPresent(5),
notFunctioning(6),
restore(7),
notAvailable(8),
backingUp(9)
}
RlEnvMonDirection ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents the state of a device being monitored.
Valid values are:
unKnown(1): if the board not support air flow direction.
frontToBack(2): the air flow direction of the fan is front to back.
backToFront(3): the air flow direction of the fan is back to front.
clockwise(4): the air flow direction of the fan is clock wise
unClockwise(5): the air flow direction of the fan is unclock wise
insideOutside(6): the air flow direction of the fan is inside outside
outsideInside(7): the air flow direction of the fan is outside inside
rightToLeft(8): the air flow direction of the fan is from right to left
leftToRight(9): the air flow direction of the fan is from left to right
"
SYNTAX INTEGER {
unKnown(1),
frontToBack(2),
backToFront(3),
clockwise(4),
unClockwise(5),
insideOut(6),
outsideIn(7),
rightToLeft(8),
leftToRight(9)
}
rlEnvPhysicalDescription OBJECT IDENTIFIER ::= { rlEnv 1 }
rlEnvMonFanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlEnvMonFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of fan status maintained by the environmental
monitor."
::= { rlEnvPhysicalDescription 1 }
rlEnvMonFanStatusEntry OBJECT-TYPE
SYNTAX RlEnvMonFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the fan status table, representing the status of
the associated fan maintained by the environmental monitor."
INDEX { rlEnvMonFanStatusIndex }
::= { rlEnvMonFanStatusTable 1 }
RlEnvMonFanStatusEntry ::=
SEQUENCE {
rlEnvMonFanStatusIndex INTEGER,
rlEnvMonFanStatusDescr DisplayString,
rlEnvMonFanState RlEnvMonState
}
rlEnvMonFanStatusIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique index for the fan being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning."
::= { rlEnvMonFanStatusEntry 1 }
rlEnvMonFanStatusDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of the fan being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry."
::= { rlEnvMonFanStatusEntry 2 }
rlEnvMonFanState OBJECT-TYPE
SYNTAX RlEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the fan being instrumented."
::= { rlEnvMonFanStatusEntry 3 }
rlEnvMonSupplyStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlEnvMonSupplyStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of power supply status maintained by the
environmental monitor card."
::= { rlEnvPhysicalDescription 2 }
rlEnvMonSupplyStatusEntry OBJECT-TYPE
SYNTAX RlEnvMonSupplyStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the power supply status table, representing the
status of the associated power supply maintained by the
environmental monitor card."
INDEX { rlEnvMonSupplyStatusIndex }
::= { rlEnvMonSupplyStatusTable 1 }
RlEnvMonSupplyStatusEntry ::=
SEQUENCE {
rlEnvMonSupplyStatusIndex INTEGER ,
rlEnvMonSupplyStatusDescr DisplayString,
rlEnvMonSupplyState RlEnvMonState,
rlEnvMonSupplySource INTEGER,
rlEnvMonSupplyFanDirection RlEnvMonDirection
}
rlEnvMonSupplyStatusIndex OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique index for the power supply being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning."
::= { rlEnvMonSupplyStatusEntry 1 }
rlEnvMonSupplyStatusDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of the power supply being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry."
::= { rlEnvMonSupplyStatusEntry 2 }
rlEnvMonSupplyState OBJECT-TYPE
SYNTAX RlEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the power supply being instrumented."
::= { rlEnvMonSupplyStatusEntry 3 }
rlEnvMonSupplySource OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ac(2),
dc(3),
externalPowerSupply(4),
internalRedundant(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power supply source.
unknown - Power supply source unknown
ac - AC power supply
dc - DC power supply
externalPowerSupply - External power supply
internalRedundant - Internal redundant power supply
"
::= { rlEnvMonSupplyStatusEntry 4 }
rlEnvMonSupplyFanDirection OBJECT-TYPE
SYNTAX RlEnvMonDirection
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of the power supply's fan."
::= { rlEnvMonSupplyStatusEntry 5 }
--------------------------------------------------------------------------------
-- rlEnvMonIndexTable
--------------------------------------------------------------------------------
rlEnvMonIndexTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlEnvMonIndexEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table that can help building indexes for EnvMon tables."
::= { rlEnvPhysicalDescription 10 }
rlEnvMonIndexEntry OBJECT-TYPE
SYNTAX RlEnvMonIndexEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table, representing the index input parameters."
INDEX { rlEnvMonIndexUnitId, rlEnvMonIndexObjType, rlEnvMonIndexObjIndex }
::= { rlEnvMonIndexTable 1 }
RlEnvMonIndexEntry ::=
SEQUENCE {
rlEnvMonIndexUnitId INTEGER,
rlEnvMonIndexObjType INTEGER,
rlEnvMonIndexObjIndex INTEGER,
rlEnvMonIndexValue INTEGER
}
rlEnvMonIndexUnitId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unit ID."
::= { rlEnvMonIndexEntry 1 }
rlEnvMonIndexObjType OBJECT-TYPE
SYNTAX INTEGER {
powerSupply(5),
fan(6),
thermalSensorUnderCard(14)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Object type."
::= { rlEnvMonIndexEntry 2 }
rlEnvMonIndexObjIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of object."
::= { rlEnvMonIndexEntry 3 }
rlEnvMonIndexValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Calculated index value."
::= { rlEnvMonIndexEntry 4 }
rlEnvFanData OBJECT IDENTIFIER ::= { rlEnv 5 }
rlEnvFanDataTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlEnvFanDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each unit in a stack"
::= { rlEnvFanData 1 }
rlEnvFanDataEntry OBJECT-TYPE
SYNTAX RlEnvFanDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of this table specifies a unit"
INDEX { rlEnvFanDataStackUnit }
::= { rlEnvFanDataTable 1 }
RlEnvFanDataEntry ::= SEQUENCE {
rlEnvFanDataStackUnit INTEGER,
rlEnvFanDataTemp INTEGER,
rlEnvFanDataSpeed INTEGER,
rlEnvFanDataOperLevel INTEGER,
rlEnvFanDataAdminLevel INTEGER,
rlEnvFanDataDirection RlEnvMonDirection
}
rlEnvFanDataStackUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the stack unit"
::= { rlEnvFanDataEntry 1 }
rlEnvFanDataTemp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit temperature"
::= { rlEnvFanDataEntry 2 }
rlEnvFanDataSpeed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fan speed in RPM"
::= { rlEnvFanDataEntry 3 }
rlEnvFanDataOperLevel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fan speed operative level"
::= { rlEnvFanDataEntry 4 }
rlEnvFanDataAdminLevel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured fan speed level"
::= { rlEnvFanDataEntry 5 }
rlEnvFanDataDirection OBJECT-TYPE
SYNTAX RlEnvMonDirection
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of the system's fan."
::= { rlEnvFanDataEntry 6 }
-- ************ Redundant Fan ************** --
RlEnvRedundantFanStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents the status of a redundant fan.
Valid values are:
Ready(1): fan is ready and not active (all fans are O.K)
Active(2): fan is active (one or more fan failed)
Failure(3): fan failure "
SYNTAX INTEGER {
ready(1),
active(2),
failure(3),
notPresent(4)
}
rlEnvRedundantFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlEnvRedundantFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of redundant fan status"
::= { rlEnv 6 }
rlEnvRedundantFanEntry OBJECT-TYPE
SYNTAX RlEnvRedundantFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the redundant fan status table, representing the status of the associated fan "
INDEX { rlEnvRedundantFanUnitId, rlEnvRedundantFanIndex }
::= { rlEnvRedundantFanTable 1 }
RlEnvRedundantFanEntry ::=
SEQUENCE {
rlEnvRedundantFanUnitId Unsigned32,
rlEnvRedundantFanIndex INTEGER,
rlEnvRedundantFanStatus RlEnvRedundantFanStatus
}
rlEnvRedundantFanUnitId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the stack unit"
::= { rlEnvRedundantFanEntry 1 }
rlEnvRedundantFanIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fan index"
::= { rlEnvRedundantFanEntry 2 }
rlEnvRedundantFanStatus OBJECT-TYPE
SYNTAX RlEnvRedundantFanStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fan status"
::= { rlEnvRedundantFanEntry 3 }
rlEnvRedundantFanSupported OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Defines whether Redundant Fan feature is supported"
::= { rlEnv 7 }
END