CTRON-COMMON-MIB DEFINITIONS ::= BEGIN
-- ctron-common-mib.txt
-- Part Number: 2170549-01
-- Revision: 1.03.03
-- Date: December 9, 1997
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- support@ctron.com
-- This module provides authoritative definitions for Cabletron's
-- enterprise-specific common MIB.
--
-- This module will be extended, as required.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright August 94 Cabletron Systems
IMPORTS
NetworkAddress, Counter
FROM RFC1155-SMI
subSysMMAC, subSysDevice, ups,
commonRev1, dl
FROM IRM-OIDS
DisplayString, PhysAddress
FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212;
-- Updated to Revision 1.01 on January 31, 1992. Added
-- download group.
-- This MIB module uses the extended OBJECT-TYPE macro as defined
-- in [9];
-- Textual convention
-- DisplayString ::= OCTET STRING
-- This data type is used to model textual information taken from
-- the NVT ASCII character set. By convention, objects with this
-- syntax are declared as having:
--
-- SIZE (0..255)
-- PhysAddress ::= OCTET STRING
-- This data type is used to model media addresses. For many
-- types of media, this will be in a binary representation. For
-- example, an Ethernet address would be represented as a string
-- of 6 octets.
fnb2 OBJECT IDENTIFIER ::= { subSysMMAC 2 }
chassis OBJECT IDENTIFIER ::= { subSysMMAC 3 }
environment OBJECT IDENTIFIER ::= { subSysMMAC 4 }
fnbTR OBJECT IDENTIFIER ::= { fnb2 1 }
fnbCSMACD OBJECT IDENTIFIER ::= { fnb2 2 }
fnbPortConnect OBJECT IDENTIFIER ::= { fnb2 3 }
nB55 OBJECT IDENTIFIER ::= { subSysDevice 3 }
mRXI OBJECT IDENTIFIER ::= { subSysDevice 6 }
iRM3 OBJECT IDENTIFIER ::= { subSysDevice 7 }
tRMM OBJECT IDENTIFIER ::= { subSysDevice 8 }
eMME OBJECT IDENTIFIER ::= { subSysDevice 9 }
fPRedundancy OBJECT IDENTIFIER ::= { subSysDevice 10 }
upsVersion OBJECT IDENTIFIER ::= { ups 1 }
upsRevision OBJECT IDENTIFIER ::= { upsVersion 1 }
-- The commonRev1 group
-- Implementation of this group is mandatory for all Cabletron
-- devices.
deviceType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
iRM2(176), -- integrated repeater and
-- management subsystem, version 2
iRBM(177), -- integrated repeater, bridge,
-- and management subsystem
iRM3(178), -- integrated repeater and
-- management subsystem, version 3
tRMBM-R(179), -- token ring repeater, management,
-- and bridge subsystem, type R
tRMBM-S(180), -- token ring repeater, management,
-- and bridge subsystem, type S
emm-E(185), -- ethernet repeater, management,
-- and bridge subsystem
tRMM(187), -- token ring repeater and
-- management subsystem
trmMim(190), -- token ring repeater MIM
mrxi24(65569), -- integrated repeater and
-- management subsytem with 24
-- 10BaseT ports (RJ45), 2 EPIMs
mrxi22(65570), -- integrated repeater and
-- management subsytem with 12
-- 10BaseT ports (RJ45), 1 EPIM
mrxi34(65571), -- integrated repeater and
-- management subsytem with 24
-- 10BaseT ports (50-POS CHAMP), 1 EPIM
mrxi38(65572) -- integrated repeater and
-- management subsytem with 48
-- 10BaseT ports (50-POS CHAMP), 2 EPIMs
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of management board."
::= { commonRev1 1 }
deviceName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A textual description on the entity managed by the
resident agent. It is mandatory that this only con-
tain printable ASCII characters."
::= { commonRev1 2 }
deviceIPAddress OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Network address, in this case the IP address,
of the device. This object is required for use by
the Local Management Interface."
::= { commonRev1 3 }
deviceTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The current time of day, in 24 hour format, as
measured by the device. The representation shall
use the standard HHMMSS format."
::= { commonRev1 4 }
deviceDate OBJECT-TYPE
SYNTAX DisplayString (SIZE(8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The current date, as measured by the device. The
representation shall use the standard MMDDYYYY
format."
::= { commonRev1 5 }
-- The fnbTR group implementation of this group is optional
-- Implementation of this group is mandatory for Token Ring
-- subsystems on devices that incorporate the FNB.
fnbTRTable OBJECT-TYPE
SYNTAX SEQUENCE OF FnbTREntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of entries that provide connection status of
Token Ring subsystems, for the FNB."
::= { fnbTR 1 }
fnbTREntry OBJECT-TYPE
SYNTAX FnbTREntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the fnbTRTable containing objects that
provide FNB connection status for a Token Ring sub-
system."
INDEX { fnbTRIndex }
::= { fnbTRTable 1 }
FnbTREntry ::=
SEQUENCE {
fnbTRIndex
INTEGER,
fnbConnectLeft
INTEGER,
fnbConnectRight
INTEGER,
fnbBypass
INTEGER,
fnbRPBypass
INTEGER
}
fnbTRIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An unique value for each Token Ring subsystem. Its
value ranges between 1 and chassisSlots. The value
for each interface must remain constant, at least,
from one re-initialization of the entity's network
management system to the next re-initialization."
::= { fnbTREntry 1 }
fnbConnectLeft OBJECT-TYPE
SYNTAX INTEGER {
detached(1),
attached(2),
faulted(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Connected Left board (board n + 1) has the following
states:
Detached == 1 (Management (only management) detached,
read/write).
Attached == 2 (Management/AutoMode attached, read/write).
Faulted == 3 (Management/AutoMode tried to attach but
failed READ ONLY)."
::= { fnbTREntry 2 }
fnbConnectRight OBJECT-TYPE
SYNTAX INTEGER {
detached(1),
attached(2),
faulted(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Connected Right board (board n - 1) has the following states:
Detached == 1 (Management (only management) detached, read/write).
Attached == 2 (Management/AutoMode attached, read/write ).
Faulted == 3 (Management/AutoMode tried to attach but failed,
READ ONLY)."
::= { fnbTREntry 3 }
fnbBypass OBJECT-TYPE
SYNTAX INTEGER {
off(1), -- not bypassed
on(2) -- bypassed
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Denotes the bypass status of the current Token Ring
board. Bypassed means the board is NOT attached to the
FNB."
::= { fnbTREntry 4 }
fnbRPBypass OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Denotes the Ring Port bypass status of the current Token Ring
board. If this capability is not available on this board, the
value 'other' is returned when read, and BADSETINFO when written."
::= { fnbTREntry 5 }
-- The fnbCSMACD group
-- Implementation of this group is mandatory for CSMA/CD
-- subsystems on devices that incorporate the FNB.
fnbCSMACDTable OBJECT-TYPE
SYNTAX SEQUENCE OF FnbCSMACDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of entries that provide connection status of
CSMA/CD subsystems, for the FNB."
::= { fnbCSMACD 1 }
fnbCSMACDEntry OBJECT-TYPE
SYNTAX FnbCSMACDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the fnbCSMACDTable containing objects
that provide FNB connection status for a CSMA/CD
subsystem."
INDEX { fnbCSMACDIndex }
::= { fnbCSMACDTable 1 }
FnbCSMACDEntry ::=
SEQUENCE {
fnbCSMACDIndex
INTEGER,
fnbConnect
INTEGER,
fnbPortChanges
Counter
}
fnbCSMACDIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An unique value for each CSMACD subsystem. Its
value ranges between 1 and chassisSlots. The value
for each interface must remain constant, at least,
from one re-initialization of the entity's network
management system to the next re-initialization."
::= { fnbCSMACDEntry 1 }
fnbConnect OBJECT-TYPE
SYNTAX INTEGER {
connectB(1),
connectC(2),
disconnect(3),
connectA(4),
subnetB(5),
subnetC(6),
multiChannel(7),
frontPanel(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Denotes the connection status of the CSMA/CD board
to the inter-RIC bus."
::= { fnbCSMACDEntry 2 }
fnbPortChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the number of times any port on the
given MIM has changed it's connection to the
inter-RIC bus."
::= { fnbCSMACDEntry 3 }
-- The fnbPortConnect group. This group is required only for those devices
-- that support port switching
fnbPortConnectTable OBJECT-TYPE
SYNTAX SEQUENCE OF FnbPortConnectEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table is used to control port
association on ethernet devices. Only
those boards that support port switching
will be listed in this table."
::= { fnbPortConnect 1 }
fnbPortConnectEntry OBJECT-TYPE
SYNTAX FnbPortConnectEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Describes a specific port connection entry."
INDEX { fnbPortConnectBoardIndex, fnbPortConnectPortIndex }
::= { fnbPortConnectTable 1 }
FnbPortConnectEntry ::= SEQUENCE {
fnbPortConnectBoardIndex
INTEGER,
fnbPortConnectPortIndex
INTEGER,
fnbPortConnectPortAssignment
INTEGER,
fnbPortConnectCompID
INTEGER
}
fnbPortConnectBoardIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An instance of a board for which this port
assignment relationship exists."
::= { fnbPortConnectEntry 1 }
fnbPortConnectPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An instance of a port for which this
assignment relationship exists."
::= { fnbPortConnectEntry 2 }
fnbPortConnectPortAssignment OBJECT-TYPE
SYNTAX INTEGER {
connectA(1),
connectB(2),
connectC(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The specific channel that the port is
assigned."
::= { fnbPortConnectEntry 3 }
fnbPortConnectCompID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the component ID as defined in the chassis
MIB that this port is associated with. These
components will be repeater components."
::= { fnbPortConnectEntry 4 }
fnbPortConnectionChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maintains the number of times any port within
the mangement domain of this MIM changes it's
port assignment."
::= { fnbPortConnect 2 }
-- The chassis group
-- Implementation of this group is mandatory for all cabletron
-- devices. Except for bounded slotless entities.
chassisHWRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Define the hardware revision of the device or sys-
tem chassis."
::= { chassis 1 }
chassisType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
mMAC8FNB(2), -- non shunting
mMAC5FNB(3), -- non shunting
mMAC3FNB(4), -- non shunting
mINIMMAC(5),
mRXI(6),
m3FNB(7), -- shunting
m5FNB(8), -- shunting
m8FNB(9), -- non shunting
nonFNB(10),
mMAC3FNBS(11), -- shunting
mMAC5FNBS(12), -- shunting
mMAC8FNBS(13), -- shunting
m8FNBS(14) -- shunting
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the type of chassis."
::= { chassis 2 }
chassisSlots OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the number of available chassis slots."
::= { chassis 3 }
chassisFNB OBJECT-TYPE
SYNTAX INTEGER {
absent(1),
present(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the presence or absence of the FNB."
::= { chassis 4 }
chassisAlarmEna OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allow an audible alarm to be either enabled or dis-
abled."
::= { chassis 5 }
chassisAlarmState OBJECT-TYPE
SYNTAX INTEGER {
chassisNoFaultCondition(1),
chassisFaultCondition(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Denotes the current condition of the power supply
fault detection circuit. Setting a value of
chassisNoFaultCondition(1) disables the current
chassis alarm condition, and stops the current
audible alarm from sounding. Setting a value of
chassisFaultCondition(2) is not allowed.
This object will read with the value of
chassisNoFaultCondition(1) when the chassis is
currently operating with no power faults detected.
This object will read with the value of
chassisFaultCondition(2) when the chassis is
currently in a power fault condition."
::= { chassis 6 }
-- The environment group
-- Implementation of this group is optional
powerTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of power supply entries."
::= { environment 1 }
powerEntry OBJECT-TYPE
SYNTAX PowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the powerTable providing objects for a
power supply."
INDEX { powerSupplyNum }
::= { powerTable 1 }
PowerEntry ::=
SEQUENCE {
powerSupplyNum
INTEGER,
powerSupplyState
INTEGER,
powerSupplyId
OBJECT IDENTIFIER,
powerSupplyRedun
INTEGER,
powerSupplyRemoteDisable
INTEGER
}
powerSupplyNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the power supply that may have failed."
::= { powerEntry 1 }
powerSupplyState OBJECT-TYPE
SYNTAX INTEGER {
infoNotAvailable(1),
notInstalled(2),
installedAndOperating(3),
installedAndNotOperating(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the power supply's state."
::= { powerEntry 2 }
powerSupplyId OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identifies the type of power supply. For example, this
could be used to identify power supplies which support
additional remote management capabilities."
::= { powerEntry 3 }
powerSupplyRedun OBJECT-TYPE
SYNTAX INTEGER {
redundancyAvail(1),
redundancyNotAvail(2),
infoNotAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identifies whether power redundancy is available
within the chassis.
Devices that do not support power supply redundancy,
will return infoNotAvailable."
::= { powerEntry 4 }
powerSupplyRemoteDisable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2),
infoNotAvailable(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Provides Enable/Disable control of the power supply.
For devices that do not support this capability, a set
attempt will return BADVALUE, and a read will always
return infoNotAvailable."
::= { powerEntry 5 }
-- The nB55 group
-- Implementation of this group is mandatory for the nB55 device.
nB55HWAddress OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device's MAC address."
REFERENCE
"This value is the same as ifPhysAddress in RFC
1213."
::= { nB55 1 }
nB55HWRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the revision of the nB55 board. A value of
one denotes Revision 1, a value of two denotes Revi-
sion 2, and so on."
::= { nB55 2 }
nB55FWRev OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the revision of firmware in the module.
The first octets provides the version, and the
second provides the revision."
::= { nB55 3 }
-- The mRXI group
-- Implementation of this group is mandatory for the mRXI device.
mRXIHWAddress OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device's MAC address."
REFERENCE
"This value is the same as ifPhysAddress in RFC
1213."
::= { mRXI 1 }
mRXIHWRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the revision of the mRXI board. A value of
one denotes Revision 1, a value of two denotes Revi-
sion 2, and so on."
::= { mRXI 2 }
mRXIFWRev OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the revision of firmware in the module.
The first octets provides the version, and the
second provides the revision."
::= { mRXI 3 }
-- The iRM3 group
-- Implementation of this group is mandatory for the iRM3 device.
iRM3HWAddress OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device's MAC address."
REFERENCE
"This value is the same as ifPhysAddress in RFC
1213."
::= { iRM3 1 }
iRM3HWRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the revision of the IRM3 board. A value of
one denotes Revision 1, a value of two denotes Revi-
sion 2, and so on."
::= { iRM3 2 }
iRM3FWRev OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the revision of firmware in the module.
The first octets provides the version, and the
second provides the revision."
::= { iRM3 3 }
iRM3PortAssoc OBJECT-TYPE
SYNTAX INTEGER {
aoffFrp(5), -- AUI is repeater, fiber
-- is off
arpFoff(6) -- AUI is off, fiber
-- is repeater
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls how front panel ports are associated
with the Irm3."
::= { iRM3 4 }
iRM3BPSupport OBJECT-TYPE
SYNTAX INTEGER {
notSupported (1),
supported (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes whether or not Backplane Protocol Support is
present in the current version of the IRM3."
::= { iRM3 5 }
-- The tRMM group
-- Implementation of this group is mandatory for the tRMM device.
tRMMHWAddress OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device's MAC address."
REFERENCE
"This value is the same as ifPhysAddress in RFC
1213."
::= { tRMM 1 }
tRMMHWRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the revision of the tRMM board. A value of
one denotes Revision 1, a value of two denotes Revi-
sion 2, and so on."
::= { tRMM 2 }
tRMMFWRev OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the revision of firmware in the module.
The first octets provides the version, and the
second provides the revision."
::= { tRMM 3 }
-- The eMME group
-- Implementation of this group is mandatory for the eMME device.
eMMEHWAddress OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device's MAC address."
REFERENCE
"This value is the same as ifPhysAddress in RFC
1213."
::= { eMME 1 }
eMMEHWRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the revision of the eMME board. A value of
one denotes Revision 1, a value of two denotes Revi-
sion 2, and so on."
::= { eMME 2 }
eMMEFWRev OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the revision of firmware in the module.
The first octets provides the version, and the
second provides the revision."
::= { eMME 3 }
eMMEBoardMap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes a bit encoded representation of the slots that
contain MIM boards. If a bit is a one then the board
is present."
::= { eMME 4 }
-- The fPredund group
-- Implementation of this group is mandatory for devices with
-- front panel redundancy.
fPRedund OBJECT IDENTIFIER ::= { fPRedundancy 1 }
fPRedundReset OBJECT-TYPE
SYNTAX INTEGER {
noReset(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If this object is set to Reset it will cause a reset
of the front panel redundancy. Setting this object to
NoReset will do nothing. This object will always be
read as NoReset."
::= { fPRedund 1 }
fPRedundPollInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Get/Set the number of seconds between polls for front
panel redundancy."
::= { fPRedund 2 }
fPRedundRetrys OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Get/Set the the number of unanswered polls allowed for
the front panel redundancy before it switches ports."
::= { fPRedund 3 }
fPRedundNumAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the number of IP Addresses associated with front panel
redundancy."
::= { fPRedund 4 }
fPRedundAddAddr OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add an IP Address to the polling list for the front panel
redundancy."
::= { fPRedund 5 }
fPRedundDelAddr OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete an IP Address from the polling list for the
front panel redundancy."
::= { fPRedund 6 }
fPRedundActivePort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Get/Set the front panel port you want to be active
when front panel redundancy is enabled."
::= { fPRedund 7 }
fPRedundEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If this object is set to enable, the front panel
redundancy will be activated. If this object is set
to disable, the front panel redundancy will be
deactivated. When read, this object will returns the
state of the object based on the last request
made."
::= { fPRedund 8 }
-- The fPredundAddr group
-- Implementation of this group is mandatory for devices with
-- front panel redundancy.
fPRedundAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF FPRedundAddrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of entries that provide IP address
information for front panel redundancy."
::= { fPRedundancy 2 }
fPRedundAddrEntry OBJECT-TYPE
SYNTAX FPRedundAddrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the fPRedundAddrTable providing objects
for front panel redundancy."
INDEX { fPRedundAddrId }
::= { fPRedundAddrTable 1 }
FPRedundAddrEntry ::=
SEQUENCE {
fPRedundAddrId
INTEGER,
fPRedundAddrIPAddr
NetworkAddress
}
fPRedundAddrId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value identifying an element in a sequence of
member IP Addresses which belong to the front panel
redundancy. This value goes from 1 to the maximum
number of IP Addresses which may be included in
front panel redundancy."
::= { fPRedundAddrEntry 1 }
fPRedundAddrIPAddr OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Returns an IP Address associated with the front panel
redundancy."
::= { fPRedundAddrEntry 2 }
-- The ups group
-- Implementation of this group is mandatory for devices that
-- incorporate uninterruptible power supplies.
upsID OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
aPCModel370(257),
aPCModel400(258),
aPCModel600(259),
aPCModel900(260),
aPCModel1250(261),
aPCModel2000(262)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Denotes a type code which refers to the manufactur-
ers and model of the UPS."
::= { upsRevision 1 }
upsUpTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the operating time, in hours, since the UPS
was last powered on."
::= { upsRevision 2 }
upsDisable OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Allows the UPS to be disabled. A set turns of the
UPS for those systems, so equipped. A get/get-next
always returns 0."
::= { upsRevision 3 }
upsDisconnect OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allows the UPS backup power system to conserve its
battery. Setting the object to a value of 1 turns off
the power system. A get/get-next always retuns a 0."
::= { upsRevision 4 }
upsTest OBJECT-TYPE
SYNTAX INTEGER {
unitOK(1),
unitFailed(2),
badBattery(3),
noRecentTest(4), -- no test performed in the last five
-- minutes
underTest(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Denotes the status performed on the UPS. A write
unitOK(1) intiates the test. A read indicates status of
test."
::= { upsRevision 5 }
upsBatteryCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the percentage of battery capacity left,
100% being a fully-charged battery."
::= { upsRevision 6 }
upsACLineVoltsIn OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the input AC utility line voltage."
::= { upsRevision 7 }
upsBatteryVoltsOut OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the battery voltage."
::= { upsRevision 8 }
-- The dl group
-- Implementation of this group is mandatory for systems
-- that provide the ability to download firmware."
dlForceOnBoot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When set to a 1, the system will request a
download, during the next system restart.
If no server is found and the current image
in flash memory is valid, the system will boot
using the flash-resident image."
::= { dl 1 }
dlCommitRAMToFlash OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When written with a 1, the boot software will erase
flash memory, compress the downloaded code, and save
the compressed image into flash memory. Upon com-
pletion of this operation, the flash memory driver
resets this object to 0, indicating completion of
the programming operation."
::= { dl 2 }
dlInitiateColdBoot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When written with a 1, the boot software intiates a
system reboot. All MIB variables used to control
the exact nature of the download should be set,
prior to activating a system reset.
A read always returns a 0."
::= { dl 3 }
dlTFTPRequestHost OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the server to be used, when
firmware is to be loaded across the network."
::= { dl 4 }
dlTFTPRequest OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The filename requested of the server, when firmware
is to be loaded across the network."
::= { dl 5 }
dlLastImageFilename OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Filename of the last image to be successfully
loaded into memory."
::= { dl 6 }
dlLastServerIPAddress OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the server used to load the
present image in flash memory."
::= { dl 7 }
dlFlashSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the size, in bytes, of flash memory con-
tained on this module."
::= { dl 8 }
dlFlashCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the number of times that flash memory has
been reprogrammed. This value is initialzed to 1,
when the module is initially powered up."
::= { dl 9 }
dlFirmwareBase OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the starting address of the firmware in
RAM."
::= { dl 10 }
dlFirmwareTop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the ending address of firmware in RAM."
::= { dl 11 }
dlFirmwareStart OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the start address of the firmware, in RAM,
as established by the boot process."
::= { dl 12 }
dlBootRev OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the revision of boot firmware in the module.
The first octets provides the version, and the
second provides the revision."
::= { dl 13 }
dlForceBootp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When set, this variable forces the client to send a
BOOTP request packet when rebooting. The client will
make several attempts before timing out if a server
does not respond. This variable stays set. When set to
a 1 it should always be read as a one. When set to zero
it should always be read as zero."
::= { dl 14 }
dlServerName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This OID is reserved for future use of the Bootp server
name. This field can be used when a client wants to get
boot information from a particular bootp server."
::= { dl 15 }
dlOnLineDownLoad OBJECT-TYPE
SYNTAX INTEGER {
normalOperation(1),
forceDownLoad(2),
forceDownLoadReset(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"During normal operation this object has the value of 1. By
setting this object to a value of forceDownLoad(2) an online
download will be performed. By setting this object to a
value of forceDownLoadReset(3) an online down load will be
performed and a reset will be forced upon successful completion
of the download."
::= { dl 16 }
dlOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
unknown(2),
normalOperation(3),
downLoadActive(4),
downLoadCompleteError(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object reflects the status of the download code. A
value of normalOperation(3) reflects either a down load was
started but has finished normally and no reset was specified
or no down load has been started. A value of downLoadActive
only appears while a down load is in progress. A value of
downLoadCompleteError reflects that a down load was started
however an error was detected."
::= { dl 17 }
dlNetAddress OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of the server to be used when an image is to be
downloaded using the Runtime TFTP Download."
::= { dl 18 }
dlFileName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Filename requested of the server when an image is to be
downloaded using the Runtime TFTP Download. This should be a
complete path filename."
::= { dl 19 }
dlErrorString OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If the value of ctDLOperStatus is downloadCompleteError(5)
then this object will provide a more complete description of
the error. Otherwise this object will be the zero length
string."
::= { dl 20 }
dlTftpServerGatewayIPAddress OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the gateway/router which connects
this SNMP agent to the TFTP server."
::= { dl 21 }
-- Enterprise specific trap definitions
-- Trap Description
-- fPRedundActivePort
-- Specific Trap Type Code - 0x15F
-- This trap indicates that a new port has been activated for the front panel
-- redundant circuit. This does NOT indicate this port is usable, but is being
-- tested.
-- The interesting information will include:
-- Active Port Number
--
-- aPCLineFail OBJECT-TYPE
-- ENTERPRISE cabletron
-- DESCRIPTION
-- "This trap is generated in the event of an AC util-
-- ity line failure."
-- ::= 0x1101
--
-- aPCLineFailRecovery OBJECT-TYPE
-- ENTERPRISE cabletron
-- DESCRIPTION
-- "This trap is generated when the UPS switches back
-- to line, and only if the aPCLineFail trap was issued
-- first."
-- ::= 0x1102
--
-- aPCLowBattery OBJECT-TYPE
-- ENTERPRISE cabletron
-- DESCRIPTION
-- "This trap is generated in the event that the UPS'
-- battery is found to be low."
-- ::= 0x1103
--
-- aPCLowBatteryRecovery OBJECT-TYPE
-- ENTERPRISE cabletron
-- DESCRIPTION
-- "This trap is generated when the UPS' battery has
-- charged above the low-battery point, and only if the
-- aPCLowBattery trap was issued first."
-- ::= 0x1104
--
-- aPCAbnormalCondition OBJECT-TYPE
-- ENTERPRISE cabletron
-- DESCRIPTION
-- "This trap is generated in the event that the UPS
-- has entered an abnormal condition, such as an over-
-- load or trip on low battery. This trap is also
-- sent, when the UPS is first turned on."
-- ::= 0x1105
--
-- aPCAbnormalConditionRecovery OBJECT-TYPE
-- ENTERPRISE cabletron
-- DESCRIPTION
-- "This trap is generated when the UPS has recovered
-- from an abnormal condition, and only if the aPCAb-
-- normalCondition trap was issued first."
-- ::= 0x1106
--
-- aPCShuttingDown OBJECT-TYPE
-- ENTERPRISE cabletron
-- DESCRIPTION
-- "This trap is generated in the event that the UPS
-- has been ordered to shut itself, or the load, off
-- over the serial line."
-- ::= 0x1107
--
--
END