mibs/MIBS/enterasys/CTRON-DCM-MIB
2023-12-05 12:25:34 +01:00

63 lines
2.1 KiB
Plaintext

CTRON-DCM-MIB DEFINITIONS ::= BEGIN
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- support@ctron.com
-- Descr
-- ctron-dcm-mib.txt
-- Revision: 1.00.00
-- Part Number:
-- Date: October 3, 1997
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages. Copyright Cabletron Systems 1996
--
--
-- This MIB allows a user to determine if a module is in standalone or
-- distributed mode, and to change the mode.
IMPORTS
OBJECT-TYPE FROM RFC-1212
ctDcm FROM CTRON-MIB-NAMES;
-- cabletron OBJECT IDENTIFIER ::= { enterprises 52}
-- mibs OBJECT IDENTIFIER ::= { cabletron 4 }
-- ctron OBJECT IDENTIFIER ::= { mibs 1 }
-- ctDcm OBJECT IDENTIFIER ::= { ctron 6 }
-- DCM is the parent branch of a group of mibs related to
-- distributed chassis management, of which Dcm is the first.
dCM OBJECT IDENTIFIER ::= { ctDcm 1 }
dCMMode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A value which indicates whether this module supports
a view chassis-wide of management information, accessed
via chassis-ip. This MIB view is actually composed of
information which is distributed between modules within
the chassis but is able to be viewed as a collective whole.
When a module is in standalone mode, it only supports
original, module-level mibs. In distributed mode, the
module will operate in conjunction with other distributed
modules to share management information and present it to
management clients through the chassis ip.
0 = STANDALONE
1 = DISTRIBUTED
"
::= { dCM 1 }
END