mibs/MIBS/enterasys/CTRON-WAN-MIB
2023-12-05 12:25:34 +01:00

3533 lines
126 KiB
Plaintext

CTRON-WAN-MIB DEFINITIONS ::= BEGIN
-- CTRON-WAN-MIB The Cabletron Wide area MIB.
-- Revision: 01.08.06
-- Part Number: 2170989
-- Date: May 20, 1998
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- support@ctron.com
-- This module provides authoritative definitions for part
-- of the naming tree below:
--
-- cabletron { enterprises 52 }
--
-- This module will be extended, as additional sub-sections
-- of this naming tree are defined.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright August 95 Cabletron Systems
IMPORTS
OBJECT-TYPE FROM RFC-1212
ctWan FROM CTRON-MIB-NAMES
DisplayString FROM RFC1213-MIB
IpAddress, Counter FROM RFC1155-SMI;
-- variables
Index ::= INTEGER
DLCI ::= INTEGER
-- DisplayString ::= OCTET STRING
--====================================================================
-- Groups
ctWanConnection OBJECT IDENTIFIER ::= { ctWan 1 }
ctWanDs1 OBJECT IDENTIFIER ::= { ctWan 2 }
ctWanRs232 OBJECT IDENTIFIER ::= { ctWan 3 }
ctFrDcp OBJECT IDENTIFIER ::= { ctWan 4 }
ctDDS OBJECT IDENTIFIER ::= { ctWan 5 }
ctDs1Alarms OBJECT IDENTIFIER ::= { ctWan 6 }
ctIPPQFilters OBJECT IDENTIFIER ::= { ctWan 7 }
ctWanHDSLExt OBJECT IDENTIFIER ::= { ctWan 8 }
-- ctWanConnection Group
-- This group is mandatory for all platforms that have one or more
-- Wan Connections
wanNumConnections OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This objects describes the number of wan connections on the
platform. A wan connection may have one or two physical ports
of which only one can be active at any time."
::= { ctWanConnection 1 }
wanConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of wan connection entries. The number of wan
connection entries is given by the value of wanNumConnections."
::= { ctWanConnection 2 }
wanConnEntry OBJECT-TYPE
SYNTAX WanConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A wan connection entry containing objects relating to
the particular wan connection."
INDEX { wanConnIndex }
::= { wanConnTable 1 }
WanConnEntry ::=
SEQUENCE {
wanConnIndex
INTEGER,
wanConnNumPhysPorts
INTEGER,
wanConnDefaultPhysPort
INTEGER,
wanConnActivePhysPort
INTEGER
}
wanConnIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each wan connection. Its value ranges
between 1 and the value wanNumConnections."
::= { wanConnEntry 1 }
wanConnNumPhysPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of physical ports that exist on this wan
connection."
::= { wanConnEntry 2 }
wanConnDefaultPhysPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The default physical port for this connection. This
indicates the physical port that should be used on this wan
connection. If redundancy is not enabled, this physical port
will always be used. If redundancy is enabled, the physical
port given here will be considered the primary physical port.
The value of this object must be set to the index of a
valid physical port (wanPhysPortIndex) for this wan connection."
::= { wanConnEntry 3 }
wanConnActivePhysPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The physical port that is currently active for this wan
connection. The value of this object indicates the
wanPhysPortIndex for the active port."
::= { wanConnEntry 4 }
wanPhysPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanPhysPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of the descriptions of the physical ports of this
platform. The number of entries is given by the value
of wanConnNumPhysPort for each Wan Connection."
::= { ctWanConnection 3 }
wanPhysPortEntry OBJECT-TYPE
SYNTAX WanPhysPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A physical port entry. It contains objects relating to a
given physical port"
INDEX { wanPhysPortConnectionIndex, wanPhysPortIndex }
::= { wanPhysPortTable 1 }
WanPhysPortEntry ::=
SEQUENCE {
wanPhysPortConnectionIndex
INTEGER,
wanPhysPortIndex
INTEGER,
wanPhysPortType
INTEGER,
wanPhysPortSpecificMib
OBJECT IDENTIFIER
}
wanPhysPortConnectionIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value indicating the wan connection this physical port
is located on."
::= { wanPhysPortEntry 1 }
wanPhysPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each physical port on a wan connection.
Its value ranges between 1 and the value wanConnNumPhysPorts."
::= { wanPhysPortEntry 2 }
wanPhysPortType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
t1(2),
e1(3),
synchronous(4),
dds(5),
di(6),
hdsl(7),
bri(8),
ds30(9),
t1DDS(10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of physical port that this entry describes. None
indicates that the physical port has no connector."
::= { wanPhysPortEntry 3 }
wanPhysPortSpecificMib OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies an instance of the index object in
the first group of objects in the MIB specific to the
physical port."
::= { wanPhysPortEntry 4 }
wanInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The interface table for a physical port on a wan connection.
It is a list of items that are pertinent to the interfaces
that are part of this physical port. The number of entries
is dependent on the wanPhysPortType for the interface.
If the wanPhysPortType is none, there will be no entries
in the table for the port. If the wanPhysPortType is t1,
there will be 24 entries in this table for the port.
If the wanPhysPortType is e1, there will be 30 entries
in this table for the port. If the wanPhysPortType is
synchronous, there will be one entry in this table for the
port. "
::= { ctWanConnection 4 }
wanInterfaceEntry OBJECT-TYPE
SYNTAX WanInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A wan connection physical port interface entry. It
contains objects relating to an interface that is defined
for this physical port and this wan connection."
INDEX { wanInterfaceConnectionIndex, wanInterfacePhysPortIndex,
wanInterfaceEntryIndex }
::= { wanInterfaceTable 1}
WanInterfaceEntry ::=
SEQUENCE {
wanInterfaceConnectionIndex
INTEGER,
wanInterfacePhysPortIndex
INTEGER,
wanInterfaceEntryIndex
INTEGER,
wanInterfaceEntryIfIndex
INTEGER,
wanInterfaceEntryProtocol
INTEGER,
wanInterfaceEntryCompression
INTEGER,
wanInterfaceEntryMTU
INTEGER,
wanInterfaceEntryLineCoding
INTEGER,
wanInterfaceEntryCrcLength
INTEGER,
wanInterfaceEntryLexProtocolEnable
INTEGER,
wanInterfaceEntryLexProtocolStatus
INTEGER,
wanInterfaceEntryCompRatio
OCTET STRING,
wanInterfaceEntryCompStatus
INTEGER,
wanInterfaceEntryBackUpIfEnable
INTEGER
}
wanInterfaceConnectionIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is the wan connection that this interface
exists on."
::= { wanInterfaceEntry 1}
wanInterfacePhysPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is the physical port of the wan connection
that this interface exists on."
::= { wanInterfaceEntry 2}
wanInterfaceEntryIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each interface of this physical port.
It is a value between 1 and the number of interfaces that
exist for the current port. The number of interfaces for
each type of port is: 24 for a port type (wanPhysPortType)
of 't1', 30 for a port type of 'e1', and 1 for a port type
of 'synchronous'. There will be no entries if the port type
is 'none'."
::= { wanInterfaceEntry 3}
wanInterfaceEntryIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ifIndex of the interface. This is the index of this entry
in the ifTable."
REFERENCE
"rfc-1213"
::= { wanInterfaceEntry 4}
wanInterfaceEntryProtocol OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The protocol that should be run on this interface. Values
are equivalent to those defined for ifType in Mib-II.
Accepted values are product dependent."
REFERENCE
"rfc-1213, product literature"
::= { wanInterfaceEntry 5}
wanInterfaceEntryCompression OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether data compression should take
place on this interface."
::= { wanInterfaceEntry 6}
wanInterfaceEntryMTU OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The MTU to be negotiated for this interface. This will not
be updated with the actual MTU, which can be found in the
ifTable."
::= { wanInterfaceEntry 7}
wanInterfaceEntryLineCoding OBJECT-TYPE
SYNTAX INTEGER {
none (1),
jBZS (2),
invHDLC (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object describes the variety of Zero Code suppression
on this interface. For an interface on a Ds1 Port, the valid
values depend on the value of the Ds1ConfigLineCode object.
If that object is set to ds1xB8ZS, then this object can be
set to none, JBZS, or InvHDLC. If the value of
Ds1ConfigLineCode is set to ds1xAMI, then this object can
only be set to JBZS, or InvHDLC. For an interface on a
Synchronous Port, the valid values are none or InvHDLC.
JBZS refers to Jammed Bit Zero suppression, which forces a
1 bit every 8 bit periods. InvHDLC refers to inverting
the HDLC data for the interface. None refers to a mode
in which some other means, such as with the Ds1ConfigLineCode
object set to dsx1B8ZS, is used to insure pulse density
requirements."
REFERENCE
"rfc-1406"
::= { wanInterfaceEntry 8}
wanInterfaceEntryCrcLength OBJECT-TYPE
SYNTAX INTEGER {
sixteen-bits(1),
thirty-two-bits(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Length of the CRC for this interface. Not all platforms
will allow all options."
::= { wanInterfaceEntry 9}
wanInterfaceEntryLexProtocolEnable OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This switch acts in concert with the wanInterfaceEntryProtocol
object. To activate LEX, this object should first be set to
enable (1), then set the wanInterfaceEntryProtocol to PPP. The
enable will have no effect if PPP is not selected. If the
wanInterfaceEntryProtocol is selected first, the default NCP of
BNCP will be selected. To De-select LEX, you must set this
object to disable (2), and wanInterfaceEntryProtocol to NONE or
reset the device. Just selecting disable (2) will not tear down
the connection."
::= { wanInterfaceEntry 10}
wanInterfaceEntryLexProtocolStatus OBJECT-TYPE
SYNTAX INTEGER {
bound (1),
unbound (2)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object reflects the current state of the link. The device
is said to be bound to the router when the physical link is OK,
the LEX negotiation is successful, and the router has been
configured correctly to communicate with this particular LAN
Extender."
::= { wanInterfaceEntry 11}
wanInterfaceEntryCompRatio OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ratio of uncompressed to compressed transmitted data.
If the data compression status is off, 1:1 will be displayed"
::= { wanInterfaceEntry 12}
wanInterfaceEntryCompStatus OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"On indicates that the compression has been successfully
negotiated and is operating. Off indicates that the
compression negotiation has failed and compression is not
operating at this time, or compression has been terminated
by either peer."
::= { wanInterfaceEntry 13}
wanInterfaceEntryBackUpIfEnable OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to select the Call-backup option.
A value of 1 is used to enable the option and a value of
2 to disable it."
::= { wanInterfaceEntry 14}
-- Wan Ds1 Group
-- This group is required for any platforms that have a t1 or e1 physical port.
--
wanDs1ExtensionsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanDs1ExtensionsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table is an extension to the standard ds1 configuration
table. It is a list of items that are pertinent to ds1 ports
on a platform. There is one entry per ds1 physical port on
the platform"
::= { ctWanDs1 1 }
wanDs1ExtensionsEntry OBJECT-TYPE
SYNTAX WanDs1ExtensionsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A ds1 extensions entry containing objects relating to
the particular ds1 physical port"
INDEX { wanDs1ExtensionsEntryIndex }
::= { wanDs1ExtensionsTable 1 }
WanDs1ExtensionsEntry ::=
SEQUENCE {
wanDs1ExtensionsEntryIndex
INTEGER,
wanDs1ExtensionsNumInterfaces
INTEGER,
wanDs1ExtensionsToggleFracTable
INTEGER,
wanDs1ExtensionsLineBuildOut
INTEGER,
wanDs1ExtensionsCFADuration
INTEGER,
wanDs1ExtensionsDIEnable
INTEGER,
wanDs1ExtensionsTotalValidIntervals
Counter,
wanDs1ExtensionsBertTestMode
INTEGER,
wanDs1ExtensionsBertRun
INTEGER,
wanDs1ExtensionsBertCurrentResults
INTEGER,
wanDs1ExtensionsBertCumulativeResults
INTEGER,
wanDs1ExtensionsBertPeakResults
INTEGER,
wanDs1ExtensionsBertAverageResult
INTEGER,
wanDs1ExtensionsBertTestPattern
INTEGER,
wanDs1ExtensionsBertSamplePeriod
INTEGER,
wanDs1ExtensionsBertNumPeriods
Counter,
wanDs1ExtensionsBertTestTraps
INTEGER,
wanDs1ExtensionsBertDataStatus
INTEGER
}
wanDs1ExtensionsEntryIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each ds1 physical port on the platform."
::= { wanDs1ExtensionsEntry 1 }
wanDs1ExtensionsNumInterfaces OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of interfaces on this physical port. This
number indicates the number of entries this physical port
uses in the ifTable."
REFERENCE
"rfc-1213"
::= { wanDs1ExtensionsEntry 2 }
wanDs1ExtensionsToggleFracTable OBJECT-TYPE
SYNTAX INTEGER {
update-table(1),
display-new(2),
display-old(3),
restore-old(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this object to 1 will cause the Ds1 Fractional Table
to be updated with the new values, as entered.
Setting this object to 2, will cause the Ds1 Fractional Table
to view as the table being entered.
Setting this object to 3, will cause the Ds1 Fractional Table
to be the table that is currently in use, regardless of
any changes being entered.
Setting this object to 4, will cause any changes that have
been made to the Ds1 Fractional Table since the last
update-table to be deleted.
For physical ports of type synchronous, this object will
have no affect, and will always return a 1."
REFERENCE
"rfc-1406"
::= { wanDs1ExtensionsEntry 3 }
wanDs1ExtensionsLineBuildOut OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
zero(2),
minus-7point5(3),
minus-15(4),
a133to266feet(5),
a266to399feet(6),
a399to533feet(7),
a533to655feet(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The line build out setting for this ds1 physical port.
Unknown indicates that the setting is neither readable or
writable."
::= { wanDs1ExtensionsEntry 4 }
wanDs1ExtensionsCFADuration OBJECT-TYPE
SYNTAX INTEGER(1..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The length of time (in seconds), that the ds1 port will
remain in the Carrier Failure Alarm state after the
alarm condition has cleared."
::= { wanDs1ExtensionsEntry 5 }
wanDs1ExtensionsDIEnable OBJECT-TYPE
SYNTAX INTEGER{
enable(1),
disable(2),
diDataEnabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables or disables Drop and Insert functionality on a
D/I WPIM. If enabled, all zero assigned timeslots will
designate D/I interface channels, if disabled all zero
channels will designate dummy channels as on a T1 or E1.
If this object is set to diDataEnabled the zero channels
will designate D/I interface channels and data to and
from the device will be transmitted or received on the
D/I port instead of the N/I port."
::= { wanDs1ExtensionsEntry 6 }
wanDs1ExtensionsTotalValidIntervals OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of previous intervals for which
valid data was collected for the DS1 mib, which
is currently RFC1406. This counter is similar to
RFC1406 dsx1ValidIntervals except that the count
represents the total number of complete 15 minute
intervals since the ds1 interface has been online,
and does not stop at the 24 hour period."
::= { wanDs1ExtensionsEntry 7 }
wanDs1ExtensionsBertTestMode OBJECT-TYPE
SYNTAX INTEGER{
none(1),
internal(2),
manual(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to request that a type of
process be in control of the testing function.
This is used to differentiate between automated test
procedures and those manually controlled by a user.
When read, this object reflects which type of process
is actually in control of the testing function. The
implementation is free to prioritize or deny requests
in a proprietary manner."
::= { wanDs1ExtensionsEntry 8 }
wanDs1ExtensionsBertRun OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls the sending of test data over this physical
port. The data is a pattern described by
wanDs1ExtensionsBertTestPattern."
::= { wanDs1ExtensionsEntry 9 }
wanDs1ExtensionsBertCurrentResults OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the results of the testing for the
last completed sampling period. A non-negative
number is the error rate in bits per million bits."
::= { wanDs1ExtensionsEntry 10 }
wanDs1ExtensionsBertCumulativeResults OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the total number of errors since the
testing was enabled. It is not a rate."
::= { wanDs1ExtensionsEntry 11 }
wanDs1ExtensionsBertPeakResults OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the highest value of
wanDs1ExtensionsBertCurrentResults since the testing
was enabled. A non-negative number is the error rate
in bits per million bits."
::= { wanDs1ExtensionsEntry 12 }
wanDs1ExtensionsBertAverageResult OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the average value of
wanDs1ExtensionsBertCurrentResults since the testing
was enabled. A non-negative number is the error rate
in bits per million bits."
::= { wanDs1ExtensionsEntry 13 }
wanDs1ExtensionsBertTestPattern OBJECT-TYPE
SYNTAX INTEGER {
patternOther(1),
pattern1s(2),
pattern63(3),
pattern511(4),
pattern2047(5),
pattern3in24(6),
patternQRSS(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to specify the pattern of the
test data."
::= { wanDs1ExtensionsEntry 14 }
wanDs1ExtensionsBertSamplePeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is the duration of time in seconds at
which the current test results will be periodically
written to wanDs1ExtensionsBertCurrentResults. The
range is 1 to 3600, with a default value of 10."
::= { wanDs1ExtensionsEntry 15 }
wanDs1ExtensionsBertNumPeriods OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The number of sampling periods that have elapsed
during the current test run."
::= { wanDs1ExtensionsEntry 16 }
wanDs1ExtensionsBertTestTraps OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to enable or disable the sending
of a trap at the conclusion of the measurement period.
The trap will contain the information described by
ctDs1BertCurrentResults. The default value is disabled."
::= { wanDs1ExtensionsEntry 17 }
wanDs1ExtensionsBertDataStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
waitingForLink(2),
waitingForLoopback(3),
running(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object provides the operating status of the
transmission of test data packets."
::= { wanDs1ExtensionsEntry 18 }
-- Wan Rs232 Group
-- This group is only required if any physical port on the system can be
-- classified as rs232-like
--
wanRs232ExtensionsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanRs232ExtensionsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table is an extension to the standard rs232-like mib.
It is a list of items that are pertinent to rs232-like ports
on a platform. There is one entry per synchronous physical
port on the platform."
REFERENCE
"rfc-1317"
::= { ctWanRs232 1 }
wanRs232ExtensionsEntry OBJECT-TYPE
SYNTAX WanRs232ExtensionsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A rs232-like extensions entry containing objects relating to
the particular rs232-like physical port."
INDEX { wanRs232ExtensionsEntryIndex }
::= { wanRs232ExtensionsTable 1 }
WanRs232ExtensionsEntry ::=
SEQUENCE {
wanRs232ExtensionsEntryIndex
INTEGER,
wanRs232ExtensionsCTSEnable
INTEGER,
wanRs232ExtensionsDSREnable
INTEGER
}
wanRs232ExtensionsEntryIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each rs232-like physical port on
the platform."
::= { wanRs232ExtensionsEntry 1 }
wanRs232ExtensionsCTSEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates whether the platform should generate
CTS. When disabled the platform will not generate CTS, when
enabled, the platform will generate CTS. The actual state
of the CTS line is available in the rs-232 like mib."
REFERENCE
"rfc-1317"
DEFVAL { disable }
::= { wanRs232ExtensionsEntry 2 }
wanRs232ExtensionsDSREnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates whether the platform should generate
DSR. When disabled the platform will not generate DSR, when
enabled, the platform will generate DSR. The actual state
of the DSR line is available in the rs-232 like mib."
REFERENCE
"rfc-1317 "
DEFVAL { disable }
::= { wanRs232ExtensionsEntry 3 }
-- ctFrDcp Group
-- This group is mandatory to support Data Compression Protocol
-- (DCP following FRF.9) for per virtual circuit basis
frDcpCircuitTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrDcpCircuitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing data compression information about
specific Data Link Connection Identifiers and corresponding
virtual circuit. This information is used to support the
frCircuitTable following RFC-1315."
::= { ctFrDcp 1 }
frDcpCircuitEntry OBJECT-TYPE
SYNTAX FrDcpCircuitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The data compression information regarding a single Data
Link Connection Identifier."
INDEX { frDcpCircuitIfIndex, frDcpCircuitDlci }
::= { frDcpCircuitTable 1 }
FrDcpCircuitEntry ::=
SEQUENCE {
frDcpCircuitIfIndex
Index,
frDcpCircuitDlci
DLCI,
frDcpCircuitEnable
INTEGER,
frDcpCircuitStatus
INTEGER,
frDcpCircuitRatio
OCTET STRING
}
frDcpCircuitIfIndex OBJECT-TYPE
SYNTAX Index
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ifIndex value of ifEntry that this DCP virtual circuit
object is layered onto."
::= { frDcpCircuitEntry 1 }
frDcpCircuitDlci OBJECT-TYPE
SYNTAX DLCI
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Data Link Connection Identifier for this DCP virtual
circuit object."
REFERENCE
"Draft American National Standard T1.618-1991, Section 3.3.6"
::= { frDcpCircuitEntry 2 }
frDcpCircuitEnable OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2) -- default
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether data compression should take place on
this particular end side virtual circuit."
::= { frDcpCircuitEntry 3 }
frDcpCircuitStatus OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"On indicates that the compression has been successfully
negotiated and is operating. Off indicates that the
compression negotiation has failed and compression is not
operating at this time, or compression has been terminated
by either peer."
::= { frDcpCircuitEntry 4 }
frDcpCircuitRatio OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (5))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ratio of uncompressed to compressed transmitted data.
If the data compression status is off, 1:1 will be displayed"
::= { frDcpCircuitEntry 5 }
--
-- Wan DDS Group
-- This group is required for any platforms that have a dds physical port.
--
ddsConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF DdsConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DDS Configuration Table"
::= { ctDDS 1}
ddsConfigEntry OBJECT-TYPE
SYNTAX DdsConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An Entry in the DDS Configuration Table"
INDEX { ddsLineIndex }
::= { ddsConfigTable 1 }
DdsConfigEntry ::=
SEQUENCE {
ddsLineIndex
INTEGER,
ddsIfIndex
INTEGER,
ddsLineMode
INTEGER,
ddsLineCoding
INTEGER,
ddsLoopbackConfig
INTEGER,
ddsLineStatus
INTEGER,
ddsTxClockSource
INTEGER,
ddsPortInSpeed
INTEGER,
ddsPortOutSpeed
INTEGER
}
ddsLineIndex OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each dds physical port on the
platform"
::= { ddsConfigEntry 1 }
ddsIfIndex OBJECT-TYPE
SYNTAX INTEGER (1..'7fffffff'h)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index associated with this dds physical port"
::= { ddsConfigEntry 2 }
ddsLineMode OBJECT-TYPE
SYNTAX INTEGER {
ddsPri (1),
ddsCc (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DDS-PRI is full duplex 56k link, No framing in loop
data so loop speed is also 56k. Data stream:
--d1 d2 d3 d4 d5 d6 d7--
DDS-CC is full duplex 64k link. Does not require framing
bit but uses a same format as SC, ninth bit position is
lumped with primary channel and not used for control.
Loop speed is 72k, Primary channel rate is 64k.
--d1 d2 d3 d4 d5 d6 d7 F d8--"
::= { ddsConfigEntry 3 }
ddsLineCoding OBJECT-TYPE
SYNTAX INTEGER {
ddsNone (1),
ddsJBZS (2),
otherLineCode (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object describes the variety of Zero Code
suppression on this interface. JBZS refers to Jammed
Bit Zero suppression, which forces a 1 bit every 8 bit
periods. None refers to a mode in which some other
means is used to insure pulse density requirements."
::= { ddsConfigEntry 4 }
ddsLoopbackConfig OBJECT-TYPE
SYNTAX INTEGER {
ddsNoLoop (1),
ddsLineLoop (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable represents the loop-back configuration
of the DDS interface. ddsNoLoop means the interface is
not in loop-back state, and LineLoop means the the
received data is looped back out."
::= { ddsConfigEntry 5 }
ddsLineStatus OBJECT-TYPE
SYNTAX INTEGER {
ddsNoAlarm (1),
ddsLossOfSignal (2),
ddsOutOfService (3),
ddsOutOfFrame (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This describes the current operational
status of DDS line."
::= { ddsConfigEntry 6 }
ddsTxClockSource OBJECT-TYPE
SYNTAX INTEGER {
ddsLoopTiming (1),
ddsLocalTiming (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The source of Transmit clock.
ddsLoopTiming - indicates that the recovered receive
clock is used as transmit clock.
ddsLocalTiming - indicates that a local clock source is
used."
::= { ddsConfigEntry 7 }
ddsPortInSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" This variable describes the current operational
receive speed of DDS line. It is a read only value
based entirely on DDS type (CC or PRI)."
::= { ddsConfigEntry 8 }
ddsPortOutSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable describes the current operational
transmit speed of DDS line. It is a read only value
based entirely on DDS type CC or PRI"
::= { ddsConfigEntry 9 }
--
-- Wan Alarms Group
-- This group is required for any platforms that support
-- Cabletron's WAN Alarm processing functionality
--
--
-- DS1 Alarms Global Configuration Variables
--
-- These parameters apply globally to the DS1 Alarms
-- entity. These variables allow the user to program
-- DS1 alarm characteristics to be the same for all DS1
-- lines installed in the device. The other option
-- available to the user would be to configure each DS1
-- line individually, using the parameters in the DS1
-- Alarms Configuration Table.
--
ds1AlarmsGlobalConfigGroup OBJECT IDENTIFIER ::= { ctDs1Alarms 1 }
ds1AlarmGlobalAdmin OBJECT-TYPE
SYNTAX INTEGER {
disabled(1), -- default
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to enable and disable the DS1 Alarm
Monitoring Application for all DS1 circuits on the
device."
::= { ds1AlarmsGlobalConfigGroup 1}
ds1AlarmGlobalAutoRecovery OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2) -- default
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to enable and disable the DS1 Alarm
Automatic Recovery feature for all DS1 circuits on
the device. For those devices that support ds1
alarm monitoring, but do not support the automatic
recovery feature, this object always returns disabled,
and performs no action when written."
::= { ds1AlarmsGlobalConfigGroup 2}
ds1AlarmGlobalTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2) -- default
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to enable and disable the DS1 Alarm
SNMP Trap generation feature for all DS1 circuits on
the device. This object operates in conjunction with
configuration of objects in the ctron-trap-mib.txt"
::= { ds1AlarmsGlobalConfigGroup 3}
ds1AlarmGlobalESCount OBJECT-TYPE
SYNTAX INTEGER (1..300) -- default is 100
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used in conjuction with ctDs1AlarmESInterval to set
the threshold for alarm generation when the number of
Errored Seconds for a specified time interval,
measured in minutes, is exceeded. The default
Errored Seconds alarm condition is 100 errored seconds
over a 6 minute time interval."
::= { ds1AlarmsGlobalConfigGroup 4}
ds1AlarmGlobalESInterval OBJECT-TYPE
SYNTAX INTEGER (1..15) -- default is 6 minutes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used in conjuction with ds1AlarmGlobalESCount to
set the threshold for alarm generation when the number
of Errored Seconds for a specified time interval,
measured in minutes, is exceeded. The default
Errored Seconds alarm condition is 100 errored seconds
over a 6 minute time interval."
::= { ds1AlarmsGlobalConfigGroup 5}
ds1AlarmGlobalBPVErrorRate OBJECT-TYPE
SYNTAX INTEGER (5..9) -- default is 6
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to specify the negative exponent of 10, used in
monitoring Bipolar Violations (Code Violations for E1)
over intervals defined by ds1AlarmGlobalBPVInterval.
For example, for a ds1AlarmGlobalBPVErrorRate value
of 6 used with a ds1AlarmGlobalBPVInterval of 15,
an alarm is generated when a 15 minute period has an
average error rate which exceeds 1 Bipolar Violation
(Code Violation for E1) per million bits.
For those devices that support ds1 alarm monitoring
but who's hardware does not support detect bipolar
violations, this object always returns the default,
and performs no action when written."
::= { ds1AlarmsGlobalConfigGroup 6}
ds1AlarmGlobalBPVInterval OBJECT-TYPE
SYNTAX INTEGER (1..15) -- default is 15 minutes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to specify the interval, used in monitoring
Bipolar Violations (Code Violations for E1)
with thresholds defined by ds1AlarmGlobalBPVErrorRate.
For example, for a ds1AlarmGlobalBPVErrorRate value
of 6 used with a ds1AlarmGlobalBPVInterval of 15, an
alarm is generated when a 15 minute period has an
average error rate which exceeds 1 Bipolar Violation
(Code Violation for E1) per million bits.
For those devices that support ds1 alarm monitoring
but who's hardware does not detect bipolar
violations, this object always returns the default,
and performs no action when written."
::= { ds1AlarmsGlobalConfigGroup 7}
ds1AlarmGlobalManualRecovery OBJECT-TYPE
SYNTAX INTEGER {
recover(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To cause a manual recovery to occur on all Ds1 circuits, this
object is set to a 1. It is always read as a 1. The recovery
will occur only when automatic recovery is disabled."
::= { ds1AlarmsGlobalConfigGroup 8}
--
-- DS1 Alarms Configuration Table
--
-- The DS1 alarm table structure contains the same information as the
-- global configuration objects, but allows seperate configuratoin of
-- specific DS1 circuits contained on the device
--
ds1AlarmConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ds1AlarmConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table containing objects used to configure DS1 alarm
functionality on a per DS1 basis."
::= { ctDs1Alarms 2 }
ds1AlarmConfigEntry OBJECT-TYPE
SYNTAX Ds1AlarmConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a single entry."
INDEX { ds1PhysNum }
::= { ds1AlarmConfigTable 1 }
Ds1AlarmConfigEntry ::=
SEQUENCE {
ds1PhysNum
INTEGER,
ds1AlarmAdmin
INTEGER,
ds1AlarmAutoRecovery
INTEGER,
ds1AlarmTrapEnable
INTEGER,
ds1AlarmESCount
INTEGER,
ds1AlarmESInterval
INTEGER,
ds1AlarmBPVErrorRate
INTEGER,
ds1AlarmBPVInterval
INTEGER,
ds1AlarmManualRecovery
INTEGER
}
ds1PhysNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value for this object is equal to the value
of a unique physical connection identifier associated
with this DS1 which is clearly labeled on the device.
For those products that do not have a DS1 identifier
labeled on the device, the value for this object is
the same as rfc1406 dsx1LineIndex."
::= { ds1AlarmConfigEntry 1 }
ds1AlarmAdmin OBJECT-TYPE
SYNTAX INTEGER {
disabled(1), -- default
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to enable and disable the DS1 Alarm
Monitoring Application for this DS1 circuit."
::= { ds1AlarmConfigEntry 2}
ds1AlarmAutoRecovery OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2) -- default
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to enable and disable the DS1 Alarm
Automatic Recovery feature for this DS1 circuit.
For those devices that support ds1
alarm monitoring, but do not support the automatic
recovery feature, this object always returns disabled,
and performs no action when written."
::= { ds1AlarmConfigEntry 3}
ds1AlarmTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2) -- default
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to enable and disable the DS1 Alarm
SNMP Trap generation feature for this DS1 circuit.
This object operates in conjunction with configuration
of objects in the ctron-trap-mib.txt"
::= { ds1AlarmConfigEntry 4}
ds1AlarmESCount OBJECT-TYPE
SYNTAX INTEGER (1..300) -- default is 100
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used in conjuction with ctDs1AlarmESInterval to set
the threshold for alarm generation when the number of
Errored Seconds for a specified time interval, measured
in minutes, is exceeded. The default Errored Seconds
alarm condition is 100 errored seconds over a 6 minute
time interval."
::= { ds1AlarmConfigEntry 5}
ds1AlarmESInterval OBJECT-TYPE
SYNTAX INTEGER (1..15) -- default is 6 minutes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used in conjuction with ctDs1AlarmESCount to set the
threshold for alarm generation when the number of
Errored Seconds for a specified time interval, measured
in minutes, is exceeded. The default Errored Seconds
alarm condition is 100 errored seconds over a 6 minute
time interval."
::= { ds1AlarmConfigEntry 6}
ds1AlarmBPVErrorRate OBJECT-TYPE
SYNTAX INTEGER (5..9) -- default is 6
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to specify the negative exponent of 10, used in
monitoring Bipolar Violations (Code Violations for E1)
over intervals defined by ds1AlarmBPVInterval. For
example, for a ds1AlarmBPVErrorRate value of 6 used
with a ds1AlarmBPVInterval of 15, an alarm is generated
when a 15 minute period has an average error rate which
exceeds 1 Bipolar Violation (Code Violation for E1) per
million bits.
For those devices that support ds1 alarm monitoring
but who's hardware does not support detect bipolar
violations, this object always returns the default,
and performs no action when written."
::= { ds1AlarmConfigEntry 7}
ds1AlarmBPVInterval OBJECT-TYPE
SYNTAX INTEGER (1..15) -- default is 15 minutes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to specify the interval, used in
monitoring Bipolar Violations (Code Violations for E1)
with thresholds defined by ds1AlarmBPVErrorRate. For
example, for a ds1AlarmBPVErrorRate value of 6 used
with a ds1AlarmBPVInterval of 15, an alarm is generated
when a 15 minute period has an average error rate
which exceeds 1 Bipolar Violation (Code Violation for
E1) per million bits.
For those devices that support ds1 alarm monitoring
but who's hardware does not support detect bipolar
violations, this object always returns the default,
and performs no action when written."
::= { ds1AlarmConfigEntry 8}
ds1AlarmManualRecovery OBJECT-TYPE
SYNTAX INTEGER {
recover(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To cause a manual recovery to occur, this object is set
to a 1. It is always read as a 1. The recovery will
occur only when automatic recovery is disabled."
::= { ds1AlarmConfigEntry 9}
--
-- Wan Internet Protocol Priority Queue Filters Group
-- This group is required for any platforms that support
-- Cabletron's WAN IP Priority Queue processing functionality
--
--
-- IP PQ Configuration Variables
--
-- These parameters apply to the IP Priority Queue
-- entity. These variables allow the user to program
-- IP addresses in a filtering database. The database
-- of IP addresses are used when a WAN service is over
-- subscribed, and the packet would normally be discarded.
-- If the IP PQ admin status is enabled, and the IP
-- address of the packet to be discarded matches one
-- programmed in the database, an attempt will be made
-- to use high priority, reserved, resources to transmit
-- the packet. The addresses programmed in this table
-- should be reserved for those packets which MUST be
-- transmitted. Some examples would be RIP, and SNMP
-- packets, who's loss would cause major networking
-- problems for the system.
--
ipPQConfigGroup OBJECT IDENTIFIER ::= { ctIPPQFilters 1 }
ipPQAdmin OBJECT-TYPE
SYNTAX INTEGER {
disabled(1), -- default
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to enable and disable the IP Priority Queue
Forwarding Application."
::= { ipPQConfigGroup 1}
iPPQMaxEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Returns the maximum number of IP address entries
supported by the IP Priority Queue application on
this device."
::= { ipPQConfigGroup 2}
iPPQNumEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the number of IP address entries currently
programmed in the ipPQAddressTable."
::= { ipPQConfigGroup 3}
iPPQAddAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add an IP address to the ipPQAddressTable. Always
read as a 0.0.0.0."
::= { ipPQConfigGroup 4 }
iPPQDelAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete an IP address from the ipPQAddressTable.
Always read as a 0.0.0.0."
::= { ipPQConfigGroup 5 }
--
--
--
-- IP Priority Queue Address Table
--
-- The IP PQ table contains a list of IP adresses used with the
-- Priority Queue filtering mechanism.
--
ipPQAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpPQAddressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table containing IP addresses, used in an
IP Priority Queue Forwarding function."
::= { ctIPPQFilters 2 }
ipPQAddressEntry OBJECT-TYPE
SYNTAX IpPQAddressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a single entry."
INDEX { ipPQAddressId }
::= { ipPQAddressTable 1 }
IpPQAddressEntry ::=
SEQUENCE {
ipPQAddressId
INTEGER,
ipPQIPAddress
IpAddress
}
ipPQAddressId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value identifying an element in a sequence
of IP PQ address entries."
::= { ipPQAddressEntry 1 }
ipPQIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Returns an IP address associated with a specific
entry in this table."
::= { ipPQAddressEntry 2 }
--
-- HDSL 15 Minute Performance History Table
-- This group provides counters for UnAvailable Seconds and
-- Errored Seconds of all HDSL connections
--
ctWanHDSLPerformance15mTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtWanHDSLPerformance15mEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"HDSL 15 minute performance table. This table provides the
accumulated counts of errored seconds (ES) and unavailable
seconds (UAS) for the HDSL line including the local, remote
units and any doublers in between during a 15 minutes period
for the last 24 hours.
The table is indexed by the non-empty slot in the device and
the 15-minute history slot within the last 24 hours period."
::= { ctWanHDSLExt 1 }
ctWanHDSLPerformance15mEntry OBJECT-TYPE
SYNTAX CtWanHDSLPerformance15mEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries in the 15 minute performance table"
INDEX
{ ctWanHDSLPerformance15mConnIndex, ctWanHDSLPerformance15mSlotIndex }
::= { ctWanHDSLPerformance15mTable 1 }
CtWanHDSLPerformance15mEntry ::= SEQUENCE {
ctWanHDSLPerformance15mConnIndex
INTEGER,
ctWanHDSLPerformance15mSlotIndex
INTEGER,
ctWanHDSLHLULoop1UAS15m
INTEGER,
ctWanHDSLHLULoop1ES15m
INTEGER,
ctWanHDSLHLULoop2UAS15m
INTEGER,
ctWanHDSLHLULoop2ES15m
INTEGER,
ctWanHDSLHRULoop1UAS15m
INTEGER,
ctWanHDSLHRULoop1ES15m
INTEGER,
ctWanHDSLHRULoop2UAS15m
INTEGER,
ctWanHDSLHRULoop2ES15m
INTEGER,
ctWanHDSLDb1NetworkLoop1UAS15m
INTEGER,
ctWanHDSLDb1NetworkLoop1ES15m
INTEGER,
ctWanHDSLDb1NetworkLoop2UAS15m
INTEGER,
ctWanHDSLDb1NetworkLoop2ES15m
INTEGER,
ctWanHDSLDb1CustomerLoop1UAS15m
INTEGER,
ctWanHDSLDb1CustomerLoop1ES15m
INTEGER,
ctWanHDSLDb1CustomerLoop2UAS15m
INTEGER,
ctWanHDSLDb1CustomerLoop2ES15m
INTEGER,
ctWanHDSLDb2NetworkLoop1UAS15m
INTEGER,
ctWanHDSLDb2NetworkLoop1ES15m
INTEGER,
ctWanHDSLDb2NetworkLoop2UAS15m
INTEGER,
ctWanHDSLDb2NetworkLoop2ES15m
INTEGER,
ctWanHDSLDb2CustomerLoop1UAS15m
INTEGER,
ctWanHDSLDb2CustomerLoop1ES15m
INTEGER,
ctWanHDSLDb2CustomerLoop2UAS15m
INTEGER,
ctWanHDSLDb2CustomerLoop2ES15m
INTEGER
}
ctWanHDSLPerformance15mConnIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identify the HDSL connection within the device, indexing from
1 to the maximum allowed number of HDSL connections in the
device."
::= { ctWanHDSLPerformance15mEntry 1 }
ctWanHDSLPerformance15mSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Define which 15-minute slot history of the HDSL within the
24 hour period. Indexing from 1 - 97 with the first index
representing the current 15-minute history"
::= { ctWanHDSLPerformance15mEntry 2 }
--
-- Local line unit's 15 minute performance history
--
ctWanHDSLHLULoop1UAS15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 1 of the local line unit during
the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 3 }
ctWanHDSLHLULoop1ES15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 1 of the local line unit during
the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 4 }
ctWanHDSLHLULoop2UAS15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 2 of the local line unit during
the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 5 }
ctWanHDSLHLULoop2ES15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the local line unit during
the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 6 }
--
-- Remote line unit's 15-minute performance history
--
ctWanHDSLHRULoop1UAS15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 1 of the remote line unit during
the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 7 }
ctWanHDSLHRULoop1ES15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 1 of the remote line unit during
the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 8 }
ctWanHDSLHRULoop2UAS15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 2 of the remote line unit during
the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 9 }
ctWanHDSLHRULoop2ES15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the remote line unit during
the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 10 }
--
-- Doubler 1's 15-minute performance history
--
ctWanHDSLDb1NetworkLoop1UAS15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
network side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 11 }
ctWanHDSLDb1NetworkLoop1ES15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 1 of the first doubler unit's
network side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 12 }
ctWanHDSLDb1NetworkLoop2UAS15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
network side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 13 }
ctWanHDSLDb1NetworkLoop2ES15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the first doubler unit's
network side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 14 }
ctWanHDSLDb1CustomerLoop1UAS15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
customer side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 15 }
ctWanHDSLDb1CustomerLoop1ES15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 1 of the first doubler unit's
customer side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 16 }
ctWanHDSLDb1CustomerLoop2UAS15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
customer side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 17 }
ctWanHDSLDb1CustomerLoop2ES15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the first doubler unit's
customer side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 18 }
--
-- Doubler 2's 15-minute performance history
--
ctWanHDSLDb2NetworkLoop1UAS15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
network side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 19 }
ctWanHDSLDb2NetworkLoop1ES15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the second doubler unit's
network side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 20 }
ctWanHDSLDb2NetworkLoop2UAS15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
network side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 21 }
ctWanHDSLDb2NetworkLoop2ES15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the second doubler unit's
network side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 22 }
ctWanHDSLDb2CustomerLoop1UAS15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
customer side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 23 }
ctWanHDSLDb2CustomerLoop1ES15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 1 of the second doubler unit's
customer side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 24 }
ctWanHDSLDb2CustomerLoop2UAS15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
customer side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 25 }
ctWanHDSLDb2CustomerLoop2ES15m OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the second doubler unit's
customer side during the 15-minute period."
::= { ctWanHDSLPerformance15mEntry 26 }
--
-- HDSL 24 hour Performance History Table
-- This group provides counters for UnAvailable Seconds and
-- Errored Seconds of all HDSL connections
--
ctWanHDSLPerformance24hTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtWanHDSLPerformance24hEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"HDSL 24-hour performance table. This table provides the
accumulated counts of errored seconds (ES) and unavailable
seconds (UAS) for the HDSL line including the local, remote
units and any doublers in between during a 24-hour period
for the last 7 days.
The table is indexed by the non-empty slot in the device and
the 24-hour history slot within the last 7 days period."
::= { ctWanHDSLExt 2 }
ctWanHDSLPerformance24hEntry OBJECT-TYPE
SYNTAX CtWanHDSLPerformance24hEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries in the 24-hour ctWanHDSLPerformance table"
INDEX
{ ctWanHDSLPerformance24hConnIndex, ctWanHDSLPerformance24hSlotIndex }
::= { ctWanHDSLPerformance24hTable 1 }
CtWanHDSLPerformance24hEntry ::= SEQUENCE {
ctWanHDSLPerformance24hConnIndex
INTEGER,
ctWanHDSLPerformance24hSlotIndex
INTEGER,
ctWanHDSLHLULoop1UAS24h
INTEGER,
ctWanHDSLHLULoop1ES24h
INTEGER,
ctWanHDSLHLULoop2UAS24h
INTEGER,
ctWanHDSLHLULoop2ES24h
INTEGER,
ctWanHDSLHRULoop1UAS24h
INTEGER,
ctWanHDSLHRULoop1ES24h
INTEGER,
ctWanHDSLHRULoop2UAS24h
INTEGER,
ctWanHDSLHRULoop2ES24h
INTEGER,
ctWanHDSLDb1NetworkLoop1UAS24h
INTEGER,
ctWanHDSLDb1NetworkLoop1ES24h
INTEGER,
ctWanHDSLDb1NetworkLoop2UAS24h
INTEGER,
ctWanHDSLDb1NetworkLoop2ES24h
INTEGER,
ctWanHDSLDb1CustomerLoop1UAS24h
INTEGER,
ctWanHDSLDb1CustomerLoop1ES24h
INTEGER,
ctWanHDSLDb1CustomerLoop2UAS24h
INTEGER,
ctWanHDSLDb1CustomerLoop2ES24h
INTEGER,
ctWanHDSLDb2NetworkLoop1UAS24h
INTEGER,
ctWanHDSLDb2NetworkLoop1ES24h
INTEGER,
ctWanHDSLDb2NetworkLoop2UAS24h
INTEGER,
ctWanHDSLDb2NetworkLoop2ES24h
INTEGER,
ctWanHDSLDb2CustomerLoop1UAS24h
INTEGER,
ctWanHDSLDb2CustomerLoop1ES24h
INTEGER,
ctWanHDSLDb2CustomerLoop2UAS24h
INTEGER,
ctWanHDSLDb2CustomerLoop2ES24h
INTEGER
}
--
-- Local line unit's 24-hour performance history
--
ctWanHDSLPerformance24hConnIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identify the HDSL connection within the device, indexing from
1 to the maximum allowed number of HDSL connections in the
device."
::= { ctWanHDSLPerformance24hEntry 1 }
ctWanHDSLPerformance24hSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Define which 24-hour slot history of the HDSL within the
last 7 days period. Indexing from 1 - 8 with the first index
representing the current 24 hour history"
::= { ctWanHDSLPerformance24hEntry 2 }
ctWanHDSLHLULoop1UAS24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 1 of the local line unit during
the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 3 }
ctWanHDSLHLULoop1ES24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 1 of the local line unit during
the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 4 }
ctWanHDSLHLULoop2UAS24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 2 of the local line unit during
the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 5 }
ctWanHDSLHLULoop2ES24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the local line unit during
the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 6 }
--
-- Remote line unit's 24 hour performance history
--
ctWanHDSLHRULoop1UAS24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 1 of the remote line unit during
the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 7 }
ctWanHDSLHRULoop1ES24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 1 of the remote line unit during
the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 8 }
ctWanHDSLHRULoop2UAS24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 2 of the remote line unit during
the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 9 }
ctWanHDSLHRULoop2ES24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the remote line unit during
the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 10 }
--
-- Doubler 1's 15-minute performance history
--
ctWanHDSLDb1NetworkLoop1UAS24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
network side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 11 }
ctWanHDSLDb1NetworkLoop1ES24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 1 of the first doubler unit's
network side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 12 }
ctWanHDSLDb1NetworkLoop2UAS24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
network side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 13 }
ctWanHDSLDb1NetworkLoop2ES24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the first doubler unit's
network side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 14 }
ctWanHDSLDb1CustomerLoop1UAS24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 1 of the first doubler unit's
customer side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 15 }
ctWanHDSLDb1CustomerLoop1ES24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 1 of the first doubler unit's
customer side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 16 }
ctWanHDSLDb1CustomerLoop2UAS24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 2 of the first doubler unit's
customer side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 17 }
ctWanHDSLDb1CustomerLoop2ES24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the first doubler unit's
customer side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 18 }
--
-- Doubler 2's 24-hour performance history
--
ctWanHDSLDb2NetworkLoop1UAS24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
network side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 19 }
ctWanHDSLDb2NetworkLoop1ES24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 1 of the second doubler unit's
network side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 20 }
ctWanHDSLDb2NetworkLoop2UAS24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
network side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 21 }
ctWanHDSLDb2NetworkLoop2ES24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the second doubler unit's
network side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 22 }
ctWanHDSLDb2CustomerLoop1UAS24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 1 of the second doubler unit's
customer side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 23 }
ctWanHDSLDb2CustomerLoop1ES24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 1 of the second doubler unit's
customer side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 24 }
ctWanHDSLDb2CustomerLoop2UAS24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unavailable seconds (UAS) on LOOP 2 of the second doubler unit's
customer side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 25 }
ctWanHDSLDb2CustomerLoop2ES24h OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Errored seconds (ES) on LOOP 2 of the second doubler unit's
customer side during the 24-hour period."
::= { ctWanHDSLPerformance24hEntry 26 }
----------------------------------------------------
-- HDSL Statistics Table
-- This group provides HDSL line statistics
----------------------------------------------------
ctWanHDSLStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtWanHDSLStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table collects the statistics for the Signal noise ratio
(SNR), and the pulse attenuation of the HDSL line, including
the local, remote units and the doublers in between."
::= { ctWanHDSLExt 3 }
ctWanHDSLStatisticsEntry OBJECT-TYPE
SYNTAX CtWanHDSLStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries of the HDSL statistics table "
INDEX
{ ctWanHDSLStatisticsHLUConnIndex }
::= { ctWanHDSLStatisticsTable 1 }
CtWanHDSLStatisticsEntry ::= SEQUENCE {
ctWanHDSLStatisticsHLUConnIndex
INTEGER,
ctWanHDSLSNRHLULoop1
INTEGER,
ctWanHDSLSNRLowHLULoop1
INTEGER,
ctWanHDSLSNRHighHLULoop1
INTEGER,
ctWanHDSLSNRHLULoop2
INTEGER,
ctWanHDSLSNRLowHLULoop2
INTEGER,
ctWanHDSLSNRHighHLULoop2
INTEGER,
ctWanHDSLPulseAttenuationHLULoop1
INTEGER,
ctWanHDSLPulseAttenuationHLULoop2
INTEGER,
ctWanHDSLBitStat1HLU
INTEGER,
ctWanHDSLSNRHRULoop1
INTEGER,
ctWanHDSLSNRLowHRULoop1
INTEGER,
ctWanHDSLSNRHighHRULoop1
INTEGER,
ctWanHDSLSNRHRULoop2
INTEGER,
ctWanHDSLSNRLowHRULoop2
INTEGER,
ctWanHDSLSNRHighHRULoop2
INTEGER,
ctWanHDSLPulseAttenuationHRULoop1
INTEGER,
ctWanHDSLPulseAttenuationHRULoop2
INTEGER,
ctWanHDSLDs1FrameHRU
INTEGER,
ctWanHDSLSNRDb1NetworkLoop1
INTEGER,
ctWanHDSLSNRLowDb1NetworkLoop1
INTEGER,
ctWanHDSLSNRHighDb1NetworkLoop1
INTEGER,
ctWanHDSLSNRDb1NetworkLoop2
INTEGER,
ctWanHDSLSNRLowDb1NetworkLoop2
INTEGER,
ctWanHDSLSNRHighDb1NetworkLoop2
INTEGER,
ctWanHDSLSNRDb1CustomerLoop1
INTEGER,
ctWanHDSLSNRLowDb1CustomerLoop1
INTEGER,
ctWanHDSLSNRHighDb1CustomerLoop1
INTEGER,
ctWanHDSLSNRDb1CustomerLoop2
INTEGER,
ctWanHDSLSNRLowDb1CustomerLoop2
INTEGER,
ctWanHDSLSNRHighDb1CustomerLoop2
INTEGER,
ctWanHDSLPulseAttenuationDb1NetworkLoop1
INTEGER,
ctWanHDSLPulseAttenuationDb1NetworkLoop2
INTEGER,
ctWanHDSLPulseAttenuationDb1CustomerLoop1
INTEGER,
ctWanHDSLPulseAttenuationDb1CustomerLoop2
INTEGER,
ctWanHDSLSNRDb2NetworkLoop1
INTEGER,
ctWanHDSLSNRLowDb2NetworkLoop1
INTEGER,
ctWanHDSLSNRHighDb2NetworkLoop1
INTEGER,
ctWanHDSLSNRDb2NetworkLoop2
INTEGER,
ctWanHDSLSNRLowDb2NetworkLoop2
INTEGER,
ctWanHDSLSNRHighDb2NetworkLoop2
INTEGER,
ctWanHDSLSNRDb2CustomerLoop1
INTEGER,
ctWanHDSLSNRLowDb2CustomerLoop1
INTEGER,
ctWanHDSLSNRHighDb2CustomerLoop1
INTEGER,
ctWanHDSLSNRDb2CustomerLoop2
INTEGER,
ctWanHDSLSNRLowDb2CustomerLoop2
INTEGER,
ctWanHDSLSNRHighDb2CustomerLoop2
INTEGER,
ctWanHDSLPulseAttenuationDb2NetworkLoop1
INTEGER,
ctWanHDSLPulseAttenuationDb2NetworkLoop2
INTEGER,
ctWanHDSLPulseAttenuationDb2CustomerLoop1
INTEGER,
ctWanHDSLPulseAttenuationDb2CustomerLoop2
INTEGER
}
--
-- Local line unit's statistics
--
ctWanHDSLStatisticsHLUConnIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identify the HDSL connection occupied in the device,
indexing from 1 to the maximum allowed connections in
the device."
::= { ctWanHDSLStatisticsEntry 1 }
ctWanHDSLSNRHLULoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current SNR on LOOP 1 of the local line unit."
::= { ctWanHDSLStatisticsEntry 2 }
ctWanHDSLSNRLowHLULoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lowest SNR on LOOP 1 of the local line unit."
::= { ctWanHDSLStatisticsEntry 3 }
ctWanHDSLSNRHighHLULoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Highest SNR on LOOP 1 of the local line unit."
::= { ctWanHDSLStatisticsEntry 4 }
ctWanHDSLSNRHLULoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current SNR on LOOP 2 of the local line unit."
::= { ctWanHDSLStatisticsEntry 5 }
ctWanHDSLSNRLowHLULoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lowest SNR on LOOP 2 of the local line unit."
::= { ctWanHDSLStatisticsEntry 6 }
ctWanHDSLSNRHighHLULoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Highest SNR on LOOP 2 of the local line unit."
::= { ctWanHDSLStatisticsEntry 7 }
ctWanHDSLPulseAttenuationHLULoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pulse Attenuation on LOOP 1 of the local line unit."
::= { ctWanHDSLStatisticsEntry 8 }
ctWanHDSLPulseAttenuationHLULoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pulse Attenuation on LOOP 2 of the local line unit."
::= { ctWanHDSLStatisticsEntry 9 }
ctWanHDSLBitStat1HLU OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A byte value which contains product specific information:
bit 0 - System in AIS on the local line unit.
1 - System in AIS on the remote line unit.
2 - Channels are reversed on the remote line unit.
3 - Channels are reversed on the doubler 1.
4 - Channels are reversed on the doubler 2.
5 - Power is fed to the next unit on the local line unit.
6 - Power is fed to the next unit on the remote line unit.
7 - Smartloop is active on remote line unit. (HiGain only)"
::= { ctWanHDSLStatisticsEntry 10 }
--
-- Remote line unit's statistics
--
ctWanHDSLSNRHRULoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current SNR on LOOP 1 of the remote line unit."
::= { ctWanHDSLStatisticsEntry 11 }
ctWanHDSLSNRLowHRULoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lowest SNR on LOOP 1 of the remote line unit."
::= { ctWanHDSLStatisticsEntry 12 }
ctWanHDSLSNRHighHRULoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Highest SNR on LOOP 1 of the remote line unit."
::= { ctWanHDSLStatisticsEntry 13 }
ctWanHDSLSNRHRULoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current SNR on LOOP 2 of the remote line unit."
::= { ctWanHDSLStatisticsEntry 14 }
ctWanHDSLSNRLowHRULoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lowest SNR on LOOP 2 of the remote line unit."
::= { ctWanHDSLStatisticsEntry 15 }
ctWanHDSLSNRHighHRULoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Highest SNR on LOOP 2 of the remote line unit."
::= { ctWanHDSLStatisticsEntry 16 }
ctWanHDSLPulseAttenuationHRULoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pulse Attenuation on LOOP 1 of the remote line unit."
::= { ctWanHDSLStatisticsEntry 17 }
ctWanHDSLPulseAttenuationHRULoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pulse Attenuation on LOOP 2 of the remote line unit."
::= { ctWanHDSLStatisticsEntry 18 }
ctWanHDSLDs1FrameHRU OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Byte value shows DS1 frame and code information for the remote
line unit (HiGain only):
bit 0:1 -
0 - frame format is SF.
1 - frame format is ESF.
2 - Frame format is unframed.
3 - no activity.
bit 2:3 -
reserved.
bit 4 -
0 - line code is AMI
1 - line code is B8ZS.
bit 5:7 -
reserved."
::= { ctWanHDSLStatisticsEntry 19 }
--
-- Doubler 1's statistics
--
ctWanHDSLSNRDb1NetworkLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current SNR on LOOP 1 of doubler 1's network side"
::= { ctWanHDSLStatisticsEntry 20 }
ctWanHDSLSNRLowDb1NetworkLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lowest SNR on LOOP 1 of doubler 1's network side"
::= { ctWanHDSLStatisticsEntry 21 }
ctWanHDSLSNRHighDb1NetworkLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Highest SNR on LOOP 1 of doubler 1's network side"
::= { ctWanHDSLStatisticsEntry 22 }
ctWanHDSLSNRDb1NetworkLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current SNR on LOOP 2 of doubler 1's network side."
::= { ctWanHDSLStatisticsEntry 23 }
ctWanHDSLSNRLowDb1NetworkLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lowest SNR on LOOP 2 of doubler 1's network side."
::= { ctWanHDSLStatisticsEntry 24 }
ctWanHDSLSNRHighDb1NetworkLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Highest SNR on LOOP 2 of doubler 1's network side."
::= { ctWanHDSLStatisticsEntry 25 }
ctWanHDSLSNRDb1CustomerLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current SNR on LOOP 1 of doubler 1's customer side."
::= { ctWanHDSLStatisticsEntry 26 }
ctWanHDSLSNRLowDb1CustomerLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lowest SNR on LOOP 1 of doubler 1's customer side."
::= { ctWanHDSLStatisticsEntry 27 }
ctWanHDSLSNRHighDb1CustomerLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Highest SNR on LOOP 1 of doubler 1's customer side."
::= { ctWanHDSLStatisticsEntry 28 }
ctWanHDSLSNRDb1CustomerLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current SNR on LOOP 2 of doubler 1's customer side."
::= { ctWanHDSLStatisticsEntry 29 }
ctWanHDSLSNRLowDb1CustomerLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lowest SNR on LOOP 2 of doubler 1's customer side."
::= { ctWanHDSLStatisticsEntry 30 }
ctWanHDSLSNRHighDb1CustomerLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Highest SNR on LOOP 2 of doubler 1's customer side."
::= { ctWanHDSLStatisticsEntry 31 }
ctWanHDSLPulseAttenuationDb1NetworkLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pulse Attenuation on LOOP 1 of doubler 1's network side."
::= { ctWanHDSLStatisticsEntry 32 }
ctWanHDSLPulseAttenuationDb1NetworkLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pulse Attenuation on LOOP 2 of doubler 1's network side."
::= { ctWanHDSLStatisticsEntry 33 }
ctWanHDSLPulseAttenuationDb1CustomerLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pulse Attenuation on LOOP 1 of doubler 1's customer side."
::= { ctWanHDSLStatisticsEntry 34 }
ctWanHDSLPulseAttenuationDb1CustomerLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pulse Attenuation on LOOP 2 of doubler 1's customer side."
::= { ctWanHDSLStatisticsEntry 35 }
--
-- Doubler 2's Statistics
--
ctWanHDSLSNRDb2NetworkLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current SNR on LOOP 1 of doubler 2's network side."
::= { ctWanHDSLStatisticsEntry 36 }
ctWanHDSLSNRLowDb2NetworkLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lowest SNR on LOOP 1 of doubler 2's network side."
::= { ctWanHDSLStatisticsEntry 37 }
ctWanHDSLSNRHighDb2NetworkLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Highest SNR on LOOP 1 of doubler 2's network side."
::= { ctWanHDSLStatisticsEntry 38 }
ctWanHDSLSNRDb2NetworkLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current SNR on LOOP 2 of doubler 2's network side."
::= { ctWanHDSLStatisticsEntry 39 }
ctWanHDSLSNRLowDb2NetworkLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lowest SNR on LOOP 2 of doubler 2's network side."
::= { ctWanHDSLStatisticsEntry 40 }
ctWanHDSLSNRHighDb2NetworkLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Highest SNR on LOOP 2 of doubler 2's network side."
::= { ctWanHDSLStatisticsEntry 41 }
ctWanHDSLSNRDb2CustomerLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current SNR on LOOP 1 of doubler 2's customer side."
::= { ctWanHDSLStatisticsEntry 42 }
ctWanHDSLSNRLowDb2CustomerLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lowest SNR on LOOP 1 of doubler 2's customer side."
::= { ctWanHDSLStatisticsEntry 43 }
ctWanHDSLSNRHighDb2CustomerLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Highest SNR on LOOP 1 of doubler 2's customer side."
::= { ctWanHDSLStatisticsEntry 44 }
ctWanHDSLSNRDb2CustomerLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current SNR on LOOP 2 of doubler 2's customer side."
::= { ctWanHDSLStatisticsEntry 45 }
ctWanHDSLSNRLowDb2CustomerLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lowest SNR on LOOP 2 of doubler 2's customer side."
::= { ctWanHDSLStatisticsEntry 46 }
ctWanHDSLSNRHighDb2CustomerLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Highest SNR on LOOP 2 of doubler 2's customer side."
::= { ctWanHDSLStatisticsEntry 47 }
ctWanHDSLPulseAttenuationDb2NetworkLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pulse Attenuation on LOOP 1 of doubler 2's network side"
::= { ctWanHDSLStatisticsEntry 48 }
ctWanHDSLPulseAttenuationDb2NetworkLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pulse Attenuation on LOOP 2 of doubler 2's network side."
::= { ctWanHDSLStatisticsEntry 49 }
ctWanHDSLPulseAttenuationDb2CustomerLoop1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pulse Attenuation on LOOP 1 of doubler 2's customer side."
::= { ctWanHDSLStatisticsEntry 50 }
ctWanHDSLPulseAttenuationDb2CustomerLoop2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pulse Attenuation on LOOP 2 of doubler 2's customer side."
::= { ctWanHDSLStatisticsEntry 51 }
----------------------------------------------------
-- HDSL Test Table
----------------------------------------------------
ctWanHDSLTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtWanHDSLTestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Test result for the HDSL line, the current test results only
apply to the local line unit. "
::= { ctWanHDSLExt 4 }
ctWanHDSLTestEntry OBJECT-TYPE
SYNTAX CtWanHDSLTestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries of the HDSL test results table."
INDEX
{ ctWanHDSLTestHLUConnIndex }
::= { ctWanHDSLTestTable 1 }
CtWanHDSLTestEntry ::= SEQUENCE {
ctWanHDSLTestHLUConnIndex
INTEGER,
ctWanHDSLTestMode
INTEGER,
ctWanHDSLHLUTestResult
INTEGER,
ctWanHDSLHRUTestResult
INTEGER
}
ctWanHDSLTestHLUConnIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identify the slot of the HDSL within the device that the user
wants to conduct the line unit test. Slot number start from
1 to maximum slots available in the device."
::= { ctWanHDSLTestEntry 1 }
ctWanHDSLTestMode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object may only be successfully set on a master device.
When this object is set, the local unit's test mode is
defined by these values when set:
1 - Normal operation
3 - Self test mode
4 - PROM check test
5 - External RAM test
6 - DS1 loop test
7 - MUX-DMUX test
9 - Analog loopback mode
13 - Transceiver mode
When getting this object, the value returned represents
the last value this object had been set to."
::= { ctWanHDSLTestEntry 2 }
ctWanHDSLHLUTestResult OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test result for the local line unit (1 - test failed, 0 - success):
bit 0 - 2180 DS1 frame sync test (HiGain only)
1 - 2180 DS1 data test (HiGain only)
2 - LIU DS1 frame sync test (HiGain only)
3 - LIU DS1 data test (HiGain only)
4 - External DS1 frame sync test (HiGain only)
5 - External DS1 data test.
6 - Mux sync test on HDSL LOOP 1
7 - Mux sync test on HDSL LOOP 2
8 - Reserved.
9 - Mux frame error test on HDSL LOOP 1
10 - Mux frame error test on HDSL LOOP 2
11 - Mux CRC test on HDSL LOOP 1
12 - Mux CRC test on HDSL LOOP 2
13 - Mux DL test on HDSL LOOP 1
14 - Mux DL test on HDSL LOOP 2
15 - Analog loopback test.
16 - Digital loop test.
17 - HGF HDSL loop test (HiGain only)
18 - HGF write/readback test (HiGain only)
19 - HGF poll lock test (HiGain only).
20 - HGF activity monitor test (HiGain only).
21 - HGF zeroes TX and detect test (HiGain only).
22 - HGF ones TX and detect test (HiGain only).
23 - Transceiver poll test on HDSL LOOP 1
24 - Transceiver poll test on HDSL LOOP 2
25 - PROM check test.
26 - External RAM test.
27 - Non-Volatile RAM test.
"
::= { ctWanHDSLTestEntry 3 }
ctWanHDSLHRUTestResult OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test results for the remote line unit,
Bit definitions correspond to those defined for
ctWanHDSLHLUTestResult. "
::= { ctWanHDSLTestEntry 4 }
----------------------------------------------------
-- HDSL Alarms Table
----------------------------------------------------
ctWanHDSLAlarmsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtWanHDSLAlarmsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table collects the existing alarms information for the HDSL
line, including the local, remote line units and the doublers."
::= { ctWanHDSLExt 5 }
ctWanHDSLAlarmsEntry OBJECT-TYPE
SYNTAX CtWanHDSLAlarmsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries for the ctWanHDSL alarms information"
INDEX
{ ctWanHDSLAlarmsHLUConnIndex }
::= { ctWanHDSLAlarmsTable 1 }
CtWanHDSLAlarmsEntry ::= SEQUENCE {
ctWanHDSLAlarmsHLUConnIndex
INTEGER,
ctWanHDSLAlarmsBackplane
INTEGER,
ctWanHDSLAlarmsES
INTEGER
}
ctWanHDSLAlarmsHLUConnIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identify which HDSL connection within the device that
the user wants to retrieve the alarm information."
::= { ctWanHDSLAlarmsEntry 1 }
ctWanHDSLAlarmsBackplane OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specific information that's related to the HDSL alarms, each bit
in the two bytes value has the following meaning if set:
Bit 0 : Local Loss of Signal on DS1 line (HiGain only).
1 : Remote Loss of Signal on DS1 list (HiGain only).
2 - 7 : reserved.
8 : Loss of Sync word on LOOP 1 of the local line unit.
9 : Loss of Sync word on LOOP 2 of the local line unit.
10 : Loss of Sync word on LOOP 1 of the first doubler.
11 : Loss of sync word on LOOP 2 of the first doubler.
12 : Loss of Sync word on LOOP 1 of the second doubler.
13 : Loss of sync word on LOOP 2 of the second doubler."
::= { ctWanHDSLAlarmsEntry 2 }
ctWanHDSLAlarmsES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A two bytes value for the Errored Second indication of the HDSL
line unit, including local, remote line units and the doublers.
each bit in the two bytes value has the following meaning if set:
Bit 0 : Errored Second on LOOP 1 of local line unit.
1 : Errored Second on LOOP 2 of local line unit.
2 : Errored Second on LOOP 1 of remote line unit.
3 : Errored Second on LOOP 2 of remote line unit.
4 : Errored Second on LOOP 1 of local line unit's network side.
5 : Errored Second on LOOP 2 of local line unit's network side.
6 : Errored Second on LOOP 1 of local line unit's customer side.
7 : Errored Second on LOOP 2 of local line unit's customer side."
::= { ctWanHDSLAlarmsEntry 3 }
----------------------------------------------------
-- HDSL Alarm History Table
----------------------------------------------------
ctWanHDSLAlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtWanHDSLAlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"HDSL Alarm History table. This table provides the accumulated
counts of Errored Seconds (ES) and Loss of Sync words (LOS)
as well as the time stamp of the above events occurred for both
of the HDSL loops.
The time stamps show the date in MMDDYYYYHHMM format."
::= { ctWanHDSLExt 6 }
ctWanHDSLAlarmHistoryEntry OBJECT-TYPE
SYNTAX CtWanHDSLAlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries in the Alarm History table"
INDEX
{ ctWanHDSLAlarmHistoryConnIndex }
::= { ctWanHDSLAlarmHistoryTable 1 }
CtWanHDSLAlarmHistoryEntry ::= SEQUENCE {
ctWanHDSLAlarmHistoryConnIndex
INTEGER,
ctWanHDSLAlHistLLOSFirst
DisplayString(SIZE(12)),
ctWanHDSLAlHistLLOSLast
DisplayString(SIZE(12)),
ctWanHDSLAlHistLLOSCurrent
INTEGER,
ctWanHDSLAlHistLLOSCount
INTEGER,
ctWanHDSLAlHistRLOSFirst
DisplayString(SIZE(12)),
ctWanHDSLAlHistRLOSLast
DisplayString(SIZE(12)),
ctWanHDSLAlHistRLOSCurrent
INTEGER,
ctWanHDSLAlHistRLOSCount
INTEGER,
ctWanHDSLAlHistLOSW1First
DisplayString(SIZE(12)),
ctWanHDSLAlHistLOSW1Last
DisplayString(SIZE(12)),
ctWanHDSLAlHistLOSW1Current
INTEGER,
ctWanHDSLAlHistLOSW1Count
INTEGER,
ctWanHDSLAlHistLOSW2First
DisplayString(SIZE(12)),
ctWanHDSLAlHistLOSW2Last
DisplayString(SIZE(12)),
ctWanHDSLAlHistLOSW2Current
INTEGER,
ctWanHDSLAlHistLOSW2Count
INTEGER,
ctWanHDSLAlHistES1First
DisplayString(SIZE(12)),
ctWanHDSLAlHistES1Last
DisplayString(SIZE(12)),
ctWanHDSLAlHistES1Current
INTEGER,
ctWanHDSLAlHistES1Count
INTEGER,
ctWanHDSLAlHistES2First
DisplayString(SIZE(12)),
ctWanHDSLAlHistES2Last
DisplayString(SIZE(12)),
ctWanHDSLAlHistES2Current
INTEGER,
ctWanHDSLAlHistES2Count
INTEGER,
ctWanHDSLAlHistMargin1First
DisplayString(SIZE(12)),
ctWanHDSLAlHistMargin1Last
DisplayString(SIZE(12)),
ctWanHDSLAlHistMargin1Current
INTEGER,
ctWanHDSLAlHistMargin1Count
INTEGER,
ctWanHDSLAlHistMargin2First
DisplayString(SIZE(12)),
ctWanHDSLAlHistMargin2Last
DisplayString(SIZE(12)),
ctWanHDSLAlHistMargin2Current
INTEGER,
ctWanHDSLAlHistMargin2Count
INTEGER,
ctWanHDSLAlHistCleared
DisplayString(SIZE(12)),
ctWanHDSLAlHistClearit
INTEGER
}
ctWanHDSLAlarmHistoryConnIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines which HDSL connection's alarm history within the
device."
::= { ctWanHDSLAlarmHistoryEntry 1 }
ctWanHDSLAlHistLLOSFirst OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the first time the DS1 Loss Of Signal (LOS)
occurred on the local side of the HDSL."
::= { ctWanHDSLAlarmHistoryEntry 2 }
ctWanHDSLAlHistLLOSLast OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the last time the DS1 Loss Of Signal (LOS)
occurred on the local side of the HDSL."
::= { ctWanHDSLAlarmHistoryEntry 3 }
ctWanHDSLAlHistLLOSCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Set if the DS1 Loss Of Signal (LOS) still occurred on the
local side of the HDSL."
::= { ctWanHDSLAlarmHistoryEntry 4 }
ctWanHDSLAlHistLLOSCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times the DS1 Loss Of Signal (LOS) occurred since
we last cleared the alarm history on the local side of the HDSL.
(HiGain only)"
::= { ctWanHDSLAlarmHistoryEntry 5 }
ctWanHDSLAlHistRLOSFirst OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the first time the DS1 Loss Of Signal (LOS)
occurred on the remote side of the HDSL. (HiGain only)"
::= { ctWanHDSLAlarmHistoryEntry 6 }
ctWanHDSLAlHistRLOSLast OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the last time the DS1 Loss Of Signal (LOS) occurred
on the remote side of the HDSL. (HiGain only)"
::= { ctWanHDSLAlarmHistoryEntry 7 }
ctWanHDSLAlHistRLOSCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Set if the DS1 Loss Of Signal (LOS) still occurred on the remote
site of the HDSL. (HiGain only)"
::= { ctWanHDSLAlarmHistoryEntry 8 }
ctWanHDSLAlHistRLOSCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times the DS1 Loss Of Signal (LOS) occurred since we
last cleared the alarm history on the remote site of the HDSL.
(HiGain only)"
::= { ctWanHDSLAlarmHistoryEntry 9 }
ctWanHDSLAlHistLOSW1First OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the first time the Loss Of Sync Word (LOSW) occurred
on the LOOP 1 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 10 }
ctWanHDSLAlHistLOSW1Last OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the last time the Loss Of Sync Word (LOSW) occurred
on the LOOP 1 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 11 }
ctWanHDSLAlHistLOSW1Current OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Set if the Loss Of Sync Word (LOSW) still occurred on the LOOP 1
of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 12 }
ctWanHDSLAlHistLOSW1Count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times the Loss Of Sync Word (LOSW) occurred since we
last cleared the history on the LOOP 1 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 13 }
ctWanHDSLAlHistLOSW2First OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the first time the Loss Of Sync Word (LOSW) occurred
on the LOOP 2 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 14 }
ctWanHDSLAlHistLOSW2Last OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the last time the Loss Of Sync Word (LOSW) occurred
on the LOOP 2 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 15 }
ctWanHDSLAlHistLOSW2Current OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Set if the Loss Of Sync Word (LOSW) still occurred on the LOOP 2
of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 16 }
ctWanHDSLAlHistLOSW2Count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times the Loss Of Sync Word (LOSW) occurred since we
last cleared the history on the LOOP 2 of the HDSL link. "
::= { ctWanHDSLAlarmHistoryEntry 17 }
ctWanHDSLAlHistES1First OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the first time the Errored Seconds (ES) occurred
on the LOOP 1 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 18 }
ctWanHDSLAlHistES1Last OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the last time the Errored Seconds (ES) occurred
on the LOOP 1 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 19 }
ctWanHDSLAlHistES1Current OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Set if the Errored Seconds (ES) still occurred on the LOOP 1 of
the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 20 }
ctWanHDSLAlHistES1Count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times the Errored Seconds (ES) occurred since we last
cleared the alarm history on the LOOP 1 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 21 }
ctWanHDSLAlHistES2First OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the first time the Errored Seconds (ES) occurred
on the LOOP 2 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 22 }
ctWanHDSLAlHistES2Last OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the last time the Errored Seconds (ES) occurred
on the LOOP 2 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 23 }
ctWanHDSLAlHistES2Current OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Set if the Errored Seconds (ES) still occurred on the LOOP 2 of
the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 24 }
ctWanHDSLAlHistES2Count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times the Errored Seconds (ES) occurred since we last
cleared the history on the LOOP 2 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 25 }
ctWanHDSLAlHistMargin1First OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the first time the alarms exceeded the
Margin Threshold on LOOP 1 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 26 }
ctWanHDSLAlHistMargin1Last OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the last time the alarms exceeded the Margin
Threshold on the LOOP 1 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 27 }
ctWanHDSLAlHistMargin1Current OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Set if the alarms still exceeded the Margin Threshold
on the LOOP 1 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 28 }
ctWanHDSLAlHistMargin1Count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times the alarm exceeded the Margin Threshold since
we last cleared the alarm history on the LOOP 1 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 29 }
ctWanHDSLAlHistMargin2First OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the first time the alarms exceeded the Margin
Threshold on LOOP 2 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 30 }
ctWanHDSLAlHistMargin2Last OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the last time the alarms exceeded the Margin
Threshold on the LOOP 2 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 31 }
ctWanHDSLAlHistMargin2Current OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Set if the alarms still exceeded the Margin Threshold
on the LOOP 2 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 32 }
ctWanHDSLAlHistMargin2Count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times the alarm exceeded the Margin Threshold since
we last cleared the alarm history on the LOOP 2 of the HDSL link."
::= { ctWanHDSLAlarmHistoryEntry 33 }
ctWanHDSLAlHistCleared OBJECT-TYPE
SYNTAX DisplayString(SIZE(12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time stamp of the time user requested to clear the alarm history."
::= { ctWanHDSLAlarmHistoryEntry 34 }
ctWanHDSLAlHistClearit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"set to a 1 to clear the alarm history.
A read of this value always returns a 1.
NOTE: the setting of this object also causes the SNR low
value, SNR high value, and the performance history to be
reset."
::= { ctWanHDSLAlarmHistoryEntry 35 }
----------------------------------------------------
-- HDSL Loopbacks Table
----------------------------------------------------
ctWanHDSLLoopbacksTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtWanHDSLLoopbacksEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"HDSL Loopback table. This table provides the certain loopback
settings for the HDSL link."
::= { ctWanHDSLExt 7 }
ctWanHDSLLoopbacksEntry OBJECT-TYPE
SYNTAX CtWanHDSLLoopbacksEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries in the HDSL Loopback table."
INDEX
{ ctWanHDSLLoopbacksHLUConnIndex }
::= { ctWanHDSLLoopbacksTable 1 }
CtWanHDSLLoopbacksEntry ::= SEQUENCE {
ctWanHDSLLoopbacksHLUConnIndex
INTEGER,
ctWanHDSLLoopbacksAdminType
INTEGER,
ctWanHDSLLoopbacksOperType
INTEGER
}
ctWanHDSLLoopbacksHLUConnIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identify the HDSL connection within the device"
::= { ctWanHDSLLoopbacksEntry 1 }
ctWanHDSLLoopbacksAdminType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the requested loopback type for the HDSL.
loopbacks setting:
1 : Smartjack - loopback to network at remote line unit.
2 : Loopback to network at local line unit.
3 : Loopback to network at remote line unit.
4 : Loopback to customer at local line unit.
5 : Loopback to customer at remote line unit.
6 : Loopback to customer at first doubler.
7 : Loopback to customer at second doubler.
8 : Loopback to network at first doubler.
9 : Loopback to network at second doubler.
10: No loopback (turn loopback off). "
::= { ctWanHDSLLoopbacksEntry 2 }
ctWanHDSLLoopbacksOperType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the operational loopback type for the HDSL.
loopbacks setting:
1 : Smartjack - loopback to network at remote line unit.
2 : Loopback to network at local line unit.
3 : Loopback to network at remote line unit.
4 : Loopback to customer at local line unit.
5 : Loopback to customer at remote line unit.
6 : Loopback to customer at first doubler.
7 : Loopback to customer at second doubler.
8 : Loopback to network at first doubler.
9 : Loopback to network at second doubler.
10: No loopback (turn loopback off). "
::= { ctWanHDSLLoopbacksEntry 3 }
END