CTRON-WEBVIEW-MIB DEFINITIONS ::= BEGIN
--
-- ctron-webview-mib.txt
-- Revision: 1.00.00
-- Part Number:
-- Date: February 8, 1999
--
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
--
-- Copyright February 99 Cabletron Systems
--
IMPORTS
OBJECT-TYPE FROM RFC-1212
DisplayString FROM RFC1213-MIB
ctApplication FROM CTRON-MIB-NAMES ;
ctWebView OBJECT IDENTIFIER ::= { ctApplication 4 }
ctEwvConfiguration OBJECT IDENTIFIER ::= { ctWebView 1 }
ctEwvStatus OBJECT IDENTIFIER ::= { ctWebView 2 }
-- ctEwvDocSupport is used to house information needed to support
-- access to WebView Help Documentation
ctEwvDocSupport OBJECT IDENTIFIER ::= { ctEwvConfiguration 1 }
ctEwvDocSupportAdmin OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable Help Content URL"
::= { ctEwvDocSupport 1 }
ctEwvDocSupportLocation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Server URL of Document Support"
::= { ctEwvDocSupport 2 }
ctEwvDocSupportAdminUID OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/Disable using username and password files"
::= { ctEwvDocSupport 3 }
ctEwvDocSupportUsername OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User ID for remote server authentication"
::= { ctEwvDocSupport 4 }
ctEwvDocSupportPassword OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Password used to determine access to documentation"
::= { ctEwvDocSupport 5 }
-- System Parameters are used to house information about the
-- WebView system
ctEwvSystemParameters OBJECT IDENTIFIER ::= { ctEwvConfiguration 2 }
ctEwvAuthScheme OBJECT-TYPE
SYNTAX INTEGER {
none(1),
basic(2),
digest(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selects the type of HTTP Authorization technique to be
employed by the WebView Server"
::= { ctEwvSystemParameters 1 }
ctEwvAuthNonceValidCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of times a server calculated nonce value will be
reused before recalculating a new nonce value"
::= { ctEwvSystemParameters 2 }
END