mibs/MIBS/ericsson/PT-FM-MIB
2023-12-05 12:25:34 +01:00

941 lines
30 KiB
Plaintext

PT-FM-MIB DEFINITIONS::=BEGIN
IMPORTS
MODULE-IDENTITY,OBJECT-TYPE,Integer32
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP FROM SNMPv2-CONF
pt FROM PT-MIB
TEXTUAL-CONVENTION, DateAndTime FROM SNMPv2-TC;
ptFM MODULE-IDENTITY
LAST-UPDATED "201603211200Z"
ORGANIZATION "Ericsson"
CONTACT-INFO
"Anders Ekvall
Postal: Ericsson AB,
E-Mail: anders.ekvall@ericsson.com"
DESCRIPTION
"This is the MIB of PT specifics"
REVISION "201603211200Z"
DESCRIPTION
"Added Managed and Reference OID to the current alarms"
REVISION "201603091200Z"
DESCRIPTION
"Validated."
REVISION "201602101230Z"
DESCRIPTION
"The initial version of this MIB module."
::= { pt 3 }
config OBJECT IDENTIFIER ::= { ptFM 1 }
alarm OBJECT IDENTIFIER ::= { ptFM 2 }
log OBJECT IDENTIFIER ::= { ptFM 3 }
ptFMConformance OBJECT IDENTIFIER ::= { ptFM 4 }
--
-- The textual conventions we define and use in this MIB.
--
NotificationIdTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Notification ID which is NONE now."
SYNTAX INTEGER {
eNONE (0)
}
MoClassTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Textual Convention for MoClass"
SYNTAX INTEGER {
eNONE (0)
}
SeverityTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer indicates the severity level, take the value of INDETERMINATE,
CRITICAL, MAJOR, MINOR, WARNING and CLEARED. "
SYNTAX INTEGER {
eINDETERMINATE (1),
eCRITICAL (2),
eMAJOR (3),
eMINOR (4),
eWARNING (5),
eCLEARED (6)
}
ProbableCauseTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Probable Cause"
SYNTAX INTEGER {
eNONE (0)
}
CategoryTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer indicates the category. "
SYNTAX INTEGER {
eHIGHORDERLEVEL (1),
eUNFILTERED (2),
eLOWORDERLEVEL (3),
eNONE (4)
}
ClearableTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer indicates whether a notification is clearable or not."
SYNTAX INTEGER {
eTRUE (1),
eFALSE (2)
}
EnableStatusTypeTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer indicates the enable status type: ENABLED or DISABLED. "
SYNTAX INTEGER {
eENABLED (1),
eDISABLED (2)
}
LayerRateTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An emulation for layer rate."
SYNTAX INTEGER {
eLRNOTAPPLICABLE (1),
eLRT3ANDDS345M (4),
eLRE12M (5),
eLRE334M (7),
eLRVT2ANDTU12VC12 (11),
eLRLOWORDERTU3VC3 (13),
eLRSTS3CANDAU4VC4 (15),
eLRSTS12CVC44C (16),
eLRSECTIONOC3STS3ANDRSSTM1 (20),
eLRSECTIONOC12STS12ANDRSSTM4 (21),
eLRSECTIONOC48STS48ANDRSSTM16 (22),
eLRLINEOC3STS3ANDMSSTM1 (25),
eLRLINEOC12STS12ANDMSSTM4 (26),
eLRLINEOC48STS48ANDMSSTM16 (27),
eLRDSROC3STM1 (73),
eLRDSROC12STM4 (74),
eLRDSROC48STM16 (76),
eLRDSRGIGABITETHERNET (87),
eLRENCAPSULATION (98),
eLRFRAGMENT (99)
}
EventTypeTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer indicates the event type: INFORMATION or WARNING. "
SYNTAX INTEGER {
eINFORMATION (1),
eWARNING (2)
}
EventCauseTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer indicates the event cause (only NONE is supported)."
SYNTAX INTEGER {
eNONE (0)
}
SwitchTypeTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer indicates the switch type. "
SYNTAX INTEGER {
eSDHMSP (1),
eSDHSNCP (2),
eEQUIPEMEMTPROTECTION (3),
eSYNCHRONISATION (4),
eSCSWITCHOVER (5)
}
SwitchReasonTC ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer indicates the switch reason. "
SYNTAX INTEGER {
eNA (1),
eRESTORED (2),
eSIGNALFAIL (3),
eSIGNALMISMATCH (4),
eSIGNALDEGRADE (5),
eAUTOMATICSWITCH (6),
eMANUAL (7),
eREMOTEREQUEST (8),
ePROTECTIONDISABLED (9),
eMODULEFAIL (10)
}
---
---The Fault Managment Group definition
---
---
--- Alarm Config Table definition
---
alarmConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This configuration defines the default severity of an alarm notification.
"
::= { config 1 }
alarmConfigEntry OBJECT-TYPE
SYNTAX AlarmConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular interface indexed by NotificationId and moClass. "
INDEX { notificationId ,moClass }
::= { alarmConfigTable 1 }
AlarmConfigEntry ::=
SEQUENCE {
notificationId NotificationIdTC,
moClass MoClassTC,
severity SeverityTC,
probableCauseQualifier OCTET STRING,
probableCause ProbableCauseTC,
category CategoryTC,
clearable ClearableTC
}
notificationId OBJECT-TYPE
SYNTAX NotificationIdTC
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Notification Id"
::= { alarmConfigEntry 1 }
moClass OBJECT-TYPE
SYNTAX MoClassTC
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MO Class"
::= { alarmConfigEntry 2 }
severity OBJECT-TYPE
SYNTAX SeverityTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SeverityTC"
::= { alarmConfigEntry 3 }
probableCauseQualifier OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Probable Cause Qualifier"
::= { alarmConfigEntry 4 }
probableCause OBJECT-TYPE
SYNTAX ProbableCauseTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Probable Cause"
::= { alarmConfigEntry 5 }
category OBJECT-TYPE
SYNTAX CategoryTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For non-clearable alarms, filtering category is NONE."
::= { alarmConfigEntry 6 }
clearable OBJECT-TYPE
SYNTAX ClearableTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates whether this is a clearable or
non-clearable alarm notification."
::= { alarmConfigEntry 7 }
---
--- AlarmPersistencyConfigTable definition
---
alarmPersistencyConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmPersistencyConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Alarm Persistency Configuration Table"
::= { config 2 }
alarmPersistencyConfigEntry OBJECT-TYPE
SYNTAX AlarmPersistencyConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular interface."
INDEX { category }
::= { alarmPersistencyConfigTable 1 }
AlarmPersistencyConfigEntry ::=
SEQUENCE {
persistencyConfigcategory CategoryTC,
onFilter Integer32,
offFilter Integer32
}
persistencyConfigcategory OBJECT-TYPE
SYNTAX CategoryTC
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Persistency Configuration category"
::= { alarmPersistencyConfigEntry 1 }
onFilter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An integer with max value of 30.
Default is 0 sec for highOrderLevel and Unfiltered,
and 3 sec for lowOrderLevel"
::= { alarmPersistencyConfigEntry 2 }
offFilter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Off Filter"
::= { alarmPersistencyConfigEntry 3 }
---NotificationConfigTable definition
notificationConfig OBJECT IDENTIFIER ::= { config 3 }
notificationReporting OBJECT-TYPE
SYNTAX EnableStatusTypeTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is used to enable or disable reporting of notifications
from the AXXMETRO device. When disabled, no notifications will be sent."
::= { notificationConfig 1 }
lCASExtendedAlarms OBJECT-TYPE
SYNTAX EnableStatusTypeTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is used to enable or disable reporting of
extended LCAS notifications."
::= { notificationConfig 2 }
nIMAlarms OBJECT-TYPE
SYNTAX EnableStatusTypeTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is used to enable or disable reporting of
notifications from the NIM objects."
::= { notificationConfig 3 }
pJEAlarms OBJECT-TYPE
SYNTAX EnableStatusTypeTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the operator changes the value from enabled to disabled,
all active PJE alarms shall be cleared.
When the operator changes the value from disabled to enabled,
event counting shall be restarted (counters reset to 0).
This attribute has node scope, ie. it impacts all PJE alarms
on all SDH ports on the node."
::= { notificationConfig 4 }
---CurrentAlarmsTable definition
currentAlarmsTable OBJECT-TYPE
SYNTAX SEQUENCE OF CurrentAlarmsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Current Alarms Table"
::= { alarm 1 }
currentAlarmsEntry OBJECT-TYPE
SYNTAX CurrentAlarmsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular interface."
INDEX {sequenceNumber}
::= { currentAlarmsTable 1 }
CurrentAlarmsEntry ::=
SEQUENCE {
sequenceNumber Integer32,
currentAlarmTimeStamp DateAndTime,
currentAlarmNotificationId NotificationIdTC,
currentAlarmManagedObjectId OCTET STRING,
currentAlarmReferenceObjectId OCTET STRING,
currentAlarmSeverity SeverityTC,
currentAlarmProbableCause ProbableCauseTC,
currentAlarmProbableCauseQualifier OCTET STRING,
currentAlarmAdditionalText OCTET STRING,
currentAlarmLayerRate LayerRateTC
}
sequenceNumber OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sequence Number"
::= { currentAlarmsEntry 1 }
currentAlarmTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time Stamp"
::= { currentAlarmsEntry 2 }
currentAlarmNotificationId OBJECT-TYPE
SYNTAX NotificationIdTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Alarm Notification Id"
::= { currentAlarmsEntry 3 }
currentAlarmManagedObjectId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the managed object id of an active alarm.
The managed object id uniquely identifies the source of the
notification and consists of class and instance information
for the source. It is represented by a formated text string
which first contains the class and depending on the class a list
of attribute name and value pairs:
'<class>:<name>=<value>;<name>=<value>;...'
<class> : class name.
<name> : attribute name.
<value> : attribute value."
::= { currentAlarmsEntry 4 }
currentAlarmReferenceObjectId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the referenced object id for the
managed object id in cases where the managed object id is
a virtual object id.
It has the same format as 'currentAlarmManagedObjectId' and
is represented by a formated text string which first contains
the class and depending on the class a list of attribute name
and value pairs:
'<class>:<name>=<value>;<name>=<value>;...'
<class> : class name.
<name> : attribute name.
<value> : attribute value."
::= { currentAlarmsEntry 5 }
currentAlarmSeverity OBJECT-TYPE
SYNTAX SeverityTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Alarm Severity"
::= { currentAlarmsEntry 6 }
currentAlarmProbableCause OBJECT-TYPE
SYNTAX ProbableCauseTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Alarm Probable Cause"
::= { currentAlarmsEntry 7 }
currentAlarmProbableCauseQualifier OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Alarm Probable Cause Qualifier"
::= { currentAlarmsEntry 8 }
currentAlarmAdditionalText OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Additional Text"
::= { currentAlarmsEntry 9 }
currentAlarmLayerRate OBJECT-TYPE
SYNTAX LayerRateTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Layer Rate"
::= { currentAlarmsEntry 10 }
---Log definition
alarmLog OBJECT IDENTIFIER ::= { log 1 }
---Alarm Log definition
maxNumOfEntriesForAlarm OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Max Number Of Entries For Alarm"
::= { alarmLog 1 }
lastSeqNumForAlarm OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last Sequence Number For Alarm"
::= { alarmLog 2 }
---AlarmLog table definition
alarmLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Alarm Log Table"
::= { alarmLog 3 }
alarmLogEntry OBJECT-TYPE
SYNTAX AlarmLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular interface."
INDEX {alarmLogSequenceNumber}
::= { alarmLogTable 1 }
AlarmLogEntry ::=
SEQUENCE {
alarmLogSequenceNumber Integer32,
alarmLogTimeStamp DateAndTime,
alarmLogNotificationId NotificationIdTC,
alarmLogSeverity SeverityTC,
alarmLogProbableCause ProbableCauseTC,
alarmLogProbableCauseQualifier OCTET STRING,
alarmLogAdditionalText OCTET STRING,
alarmLogLayerRate LayerRateTC
}
alarmLogSequenceNumber OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"AlarmLog Sequence Number"
::= { alarmLogEntry 1 }
alarmLogTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Log TimeStamp"
::= { alarmLogEntry 2 }
alarmLogNotificationId OBJECT-TYPE
SYNTAX NotificationIdTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Log Notification Id"
::= { alarmLogEntry 3 }
alarmLogSeverity OBJECT-TYPE
SYNTAX SeverityTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Log Severity"
::= { alarmLogEntry 4 }
alarmLogProbableCause OBJECT-TYPE
SYNTAX ProbableCauseTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Log Probable Cause"
::= { alarmLogEntry 5 }
alarmLogProbableCauseQualifier OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Log Probable Cause Qualifier"
::= { alarmLogEntry 6 }
alarmLogAdditionalText OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Log Additional Text"
::= { alarmLogEntry 7 }
alarmLogLayerRate OBJECT-TYPE
SYNTAX LayerRateTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Log Layer Rate"
::= { alarmLogEntry 8 }
--- TMNNotificationLog definition
tmnNotificationLog OBJECT IDENTIFIER ::= { log 2 }
maxNumOfEntriesForTMN OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Number Of Entries For TMN"
::= { tmnNotificationLog 1 }
lastSeqNumForTMN OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last Sequence Number For TMN"
::= { tmnNotificationLog 2 }
---TMNNotificationLog table definition
tmnNotificationLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnNotificationLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"TMN Notification Log Table"
::= { tmnNotificationLog 3 }
tmnNotificationLogEntry OBJECT-TYPE
SYNTAX TmnNotificationLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular interface."
INDEX {tmnSequenceNumber}
::= { tmnNotificationLogTable 1 }
TmnNotificationLogEntry ::=
SEQUENCE {
tmnSequenceNumber Integer32,
tmnTimeStamp DateAndTime,
tmnNotificationId NotificationIdTC,
tmnAdditionalText OCTET STRING
}
tmnSequenceNumber OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"TMN Sequence Number"
::= { tmnNotificationLogEntry 1 }
tmnTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TMN TimeStamp"
::= { tmnNotificationLogEntry 2 }
tmnNotificationId OBJECT-TYPE
SYNTAX NotificationIdTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TMN Notification Id"
::= { tmnNotificationLogEntry 3 }
tmnAdditionalText OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TMN Additional Text"
::= { tmnNotificationLogEntry 4 }
---EventLog definition
eventLog OBJECT IDENTIFIER ::= { log 3 }
maxNumOfEntriesForEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Number Of Entries For Event"
::= { eventLog 1 }
lastSeqNumForEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last Sequence Number For Event"
::= { eventLog 2 }
---EventLog table definition
eventLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF EventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Event Log Table"
::= { eventLog 3 }
eventLogEntry OBJECT-TYPE
SYNTAX EventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular interface."
INDEX {eventLogSequenceNumber}
::= { eventLogTable 1 }
EventLogEntry ::=
SEQUENCE {
eventLogSequenceNumber Integer32,
eventLogTimeStamp DateAndTime,
eventLogNotificationId NotificationIdTC,
eventType EventTypeTC,
eventLogAdditionalText OCTET STRING,
eventCause EventCauseTC
}
eventLogSequenceNumber OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Event Log Sequence Number"
::= { eventLogEntry 1 }
eventLogTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event Log TimeStamp"
::= { eventLogEntry 2 }
eventLogNotificationId OBJECT-TYPE
SYNTAX NotificationIdTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event Log Notification Id"
::= { eventLogEntry 3 }
eventType OBJECT-TYPE
SYNTAX EventTypeTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event Type"
::= { eventLogEntry 4 }
eventLogAdditionalText OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event Log Additional Text"
::= { eventLogEntry 5 }
eventCause OBJECT-TYPE
SYNTAX EventCauseTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Event Cause"
::= { eventLogEntry 6 }
---ProtectionSwitchLog definition
protectionSwitchLog OBJECT IDENTIFIER ::= { log 4 }
maxNumOfEntriesForSwitch OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Number Of Entries For Switch"
::= { protectionSwitchLog 1 }
lastSeqNumForSwitch OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last Sequence Number For Switch"
::= { protectionSwitchLog 2 }
---ProtectionSwitchLog table definition
protectionSwitchLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF ProtectionSwitchLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Protection Switch Log Table"
::= { protectionSwitchLog 3 }
protectionSwitchLogEntry OBJECT-TYPE
SYNTAX ProtectionSwitchLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular interface."
INDEX {switchLogSequenceNumber}
::= { protectionSwitchLogTable 1 }
ProtectionSwitchLogEntry ::=
SEQUENCE {
switchLogSequenceNumber Integer32,
switchLogTimeStamp DateAndTime,
switchLogNotificationId NotificationIdTC,
switchType SwitchTypeTC,
switchLogAdditionalText OCTET STRING,
switchReason SwitchReasonTC
}
switchLogSequenceNumber OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Switch Log Sequence Number"
::= { protectionSwitchLogEntry 1 }
switchLogTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Switch Log TimeStamp"
::= { protectionSwitchLogEntry 2 }
switchLogNotificationId OBJECT-TYPE
SYNTAX NotificationIdTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Switch Log Notification Id"
::= { protectionSwitchLogEntry 3 }
switchType OBJECT-TYPE
SYNTAX SwitchTypeTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents the type of the protection for which the switch has occurred."
::= { protectionSwitchLogEntry 4 }
switchLogAdditionalText OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Switch Log Additional Text"
::= { protectionSwitchLogEntry 5 }
switchReason OBJECT-TYPE
SYNTAX SwitchReasonTC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute represents the reason for the switch."
::= { protectionSwitchLogEntry 6 }
--
-- Conformance
--
ptFMCompliances OBJECT IDENTIFIER ::= { ptFMConformance 1 }
ptFMGroups OBJECT IDENTIFIER ::= { ptFMConformance 2 }
ptFMFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which implement everything."
MODULE -- This Module
MANDATORY-GROUPS { ptFMCompleteGroup}
::= { ptFMCompliances 1 }
ptFMCompleteGroup OBJECT-GROUP
OBJECTS
{
alarmLogTimeStamp,
alarmLogNotificationId,
alarmLogSeverity,
alarmLogProbableCause,
alarmLogProbableCauseQualifier,
alarmLogAdditionalText,
alarmLogLayerRate,
category,
clearable,
currentAlarmTimeStamp,
currentAlarmNotificationId,
currentAlarmManagedObjectId,
currentAlarmReferenceObjectId,
currentAlarmSeverity,
currentAlarmProbableCause,
currentAlarmProbableCauseQualifier,
currentAlarmAdditionalText,
currentAlarmLayerRate,
eventLogTimeStamp,
eventLogNotificationId,
eventType,
eventLogAdditionalText,
eventCause,
lastSeqNumForAlarm,
lastSeqNumForTMN,
lastSeqNumForEvent,
lastSeqNumForSwitch,
lCASExtendedAlarms,
maxNumOfEntriesForAlarm,
maxNumOfEntriesForTMN,
maxNumOfEntriesForEvent,
maxNumOfEntriesForSwitch,
notificationReporting,
nIMAlarms,
onFilter,
offFilter,
pJEAlarms,
probableCauseQualifier,
probableCause,
severity,
switchLogTimeStamp,
switchLogNotificationId,
switchType,
switchLogAdditionalText,
switchReason,
tmnTimeStamp,
tmnNotificationId,
tmnAdditionalText
}
STATUS current
DESCRIPTION
"A collection of all current objects in this MIB module."
::= { ptFMGroups 1 }
END