mibs/MIBS/ericsson/XF-RADIOLINK-RLT-MIB
2023-12-05 12:25:34 +01:00

5506 lines
188 KiB
Plaintext

XF-RADIOLINK-RLT-MIB DEFINITIONS ::= BEGIN
IMPORTS
entLogicalIndex, entPhysicalIndex
FROM ENTITY-MIB
ifIndex
FROM IF-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
OBJECT-TYPE, MODULE-IDENTITY, TimeTicks, Integer32, IpAddress, Counter32, Counter64, Gauge32
FROM SNMPv2-SMI
PerfCurrentCount, PerfIntervalCount
FROM PerfHist-TC-MIB
HCPerfCurrentCount
FROM HC-PerfHist-TC-MIB
InetAddressIPv6
FROM INET-ADDRESS-MIB
TEXTUAL-CONVENTION, DisplayString, TruthValue
FROM SNMPv2-TC
xfRadioLink
FROM XF-TOP-MIB;
xfRadioLinkRltMIB MODULE-IDENTITY
LAST-UPDATED "202011050000Z" -- 5 November 2020
ORGANIZATION
"Ericsson AB"
CONTACT-INFO
"
Ericsson AB
BURA DURA
SE-417 56 Goteborg
Sweden
"
DESCRIPTION
"
This MIB defines objects for Radio Link Terminal (RLT) and Carrier Termination (CT)
for new Radio Link application in MINI-LINK TN supporting dual carrier capability.
"
REVISION "202011050000Z" -- 5 November 2020
DESCRIPTION
"
Rev PC17
xfFrameFormatType MO: added definition of FF type for:
- 2-boards MIMO
- SISO CA
- XPIC CA
"
REVISION "202009170000Z" -- 17 September 2020
DESCRIPTION
"
Rev PC16
Added object xfRLTMeasuredHopLength in xfRLTTable:
"
REVISION "202006100000Z" -- 10 June 2020
DESCRIPTION
"
Rev PC15
TR#3054036: MIB Range validation failed:
- xfRLTNumOfRLPSwitch
"
REVISION "202006030000Z" -- 03 June 2020
DESCRIPTION
"
Rev PC14
TR#3052599: extended range for following objects (adding 0 as valid value):
- xfCarrierTermActualCapacity
- xfActualTDMCapacity
- xfCarrierTermActualLicensedCapacity
"
REVISION "202005280000Z" -- 28 May 2020
DESCRIPTION
"
Rev PC13
xfACMCapacity range extended to add 0 as valid value (TR#3045800)
"
REVISION "202004300000Z" -- 30 April 2020
DESCRIPTION
"
Rev PC12
xfRLTTDMIfTable: added 'xfTDMHopLength' object for TDM traffic delay compensation
"
REVISION "202003040000Z" -- 03 March 2020
DESCRIPTION
"
Rev PC11
xfRLTCapability: added 'capTXswoAndSSD' capability bit for TX switchover and SSD
"
REVISION "201910140000Z" -- 14 October 2019
DESCRIPTION
"
Rev PC10
In xfCarrierTerminationCapability table, xfACMprofile object is extended in order to
support 8192QAM and 16384QAM modulations.
For the same reason, following tables are updated:
- xfRLPMACMCurrent24hTable
- xfRLPMACMInterval24hTable
- xfRLPMACMCurrent15mTable
- xfRLPMACMInterval15mTable
"
REVISION "201910090000Z" -- 09 October 2019
DESCRIPTION
"
Rev PC9
new MIb added:
xfRLPMMimoCurrentTable
xfRLPMMimoCurrent24hTable
xfRLPMMimoInterval24hTable
xfRLPMMimoCurrent15mTable
xfRLPMMimoInterval15mTable
"
REVISION "201907180000Z" -- 18 July 2019
DESCRIPTION
"
Rev PC8
xfRLTTxSwitchOverConfiguration: removed value 'remote'
"
REVISION "201906070000Z" -- 07 June 2019
DESCRIPTION
"
Rev PC7
Added Selective Space Diversity support
xfRLTProtectionSwitchMode: added value 'txSwitchDisabled'
xfRLTTxSwitchOverConfiguration: added values 'local' and 'remote'
"
REVISION "201903260000Z" -- 26 March 2019
DESCRIPTION
"
Rev PC6
xfRLTCapability: added description for 'capMIMO' capability bit
"
REVISION "201903250000Z" -- 25 March 2019
DESCRIPTION
"
Rev PC5
xfRLTCapability: added 'capMIMO' capability bit for MIMO
"
REVISION "201902280000Z" -- 28 February 2019
DESCRIPTION
"
Rev PC4
xfMIMOCTmember1-4 in xfMIMOGroupTable changed access to read-only.
xfRLTEncryptionOperStatus: changed values to UP and DOWN.
"
REVISION "201902200000Z" -- 20 February 2019
DESCRIPTION
"
Rev PC3
xfFrameFormatType MO: added definition of FF type for Long Haul 2-boards XPIC.
"
REVISION "201901300000Z" -- 30 January 2019
DESCRIPTION
"
Rev PC2
xfRLTCapability: added capRLEncryption capability bit for Radio Link Encryption.
"
REVISION "201901110000Z" -- 11 January 2019
DESCRIPTION
"
Rev PC1
Added xfRLTEncryptionTable for Radio Link Encryption.
"
REVISION "201811240000Z" -- 24 November 2018
DESCRIPTION
"
Rev PB32
xfRLTFeRltSeverity renamed to xfRLTRltSeverity.
"
REVISION "201810240000Z" -- 24 October 2018
DESCRIPTION
"
Rev PB31
Changed naming of xfRLTEnhancedACMProtectionMode values in xfRLTProtectionTable:
- basic -> activeTransmitter
- maximumThroughput -> maximumCapacity
Changed name of capEnhAcmMaxThroughput into capEnhAcmMaxCapacity.
"
REVISION "201810030000Z" -- 03 October 2018
DESCRIPTION
"
Rev PB30
Added xfRLTEnhancedACMProtectionOperStatus in xfRLTProtectionTable.
"
REVISION "201809170000Z" -- 17 September 2018
DESCRIPTION
"
Rev PB29
- Added xfRLTEnhancedACMProtectionMode in xfRLTProtectionTable.
- Added cap bit in xfRLTCapability for Enhanced ACM Protection: Maximum Throughput.
- Added cap bit in xfRLTCapability for Enhanced ACM Protection: Maximum Protection.
"
REVISION "201808270000Z" -- 27 August 2018
DESCRIPTION
"
Rev PB28
xfCarrierTermXPI: modified description.
"
REVISION "201808160000Z" -- 16 August 2018
DESCRIPTION
"
Rev PB27
xfCarrierTermXPICOperStatus: Removed reference to SNIR in MO description.
"
REVISION "201807090000Z" -- 09 July 2018
DESCRIPTION
"
Rev PB26
xfFrameFormatType MO: added definition of FF type for 2-boards XPIC.
"
REVISION "201804130000Z" -- 13 April 2018
DESCRIPTION
"
Rev PB25
Type of MOs:
- xfRLTActualTxTotalCapacity
- xfRLTActualTxPacketCapacity
- xfRLTLimitedTotalCapacity
- xfCGIfMaxSpeed
- xfRLWANActualCapacity
- xfRLWANLimitedCapacity
changed to Gauge32.
"
REVISION "201804090000Z" -- 09 April 2018
DESCRIPTION
"
Rev PB24
In table xfRLTTable:
- Added bit(12) capXpicMembersAutoSelection(12)
- Added bit(13) capManualEqpSwitch(13)
"
REVISION "201803230000Z" -- 23 March 2018
DESCRIPTION
"
Rev PB23
Added to xfXPICPairTable second index:
* xfXpicPairIndex
"
REVISION "201803130000Z" -- 13 March 2018
DESCRIPTION
"
Rev PB22
Added to xfCGIfAlarms the alarm:
* unableToProtectEqp
"
REVISION "201801300000Z" -- 30 January 2018
DESCRIPTION
"
Rev PB21
In table xfRLTTable:
- xfRLTCapability bit(1) changed to capTDMWithEQP(1)
- Added bit(11) capXpicBetweenBoards(11)
"
REVISION "201712270000Z" -- 27 December 2017
DESCRIPTION
"
Rev PB20
Added values to MO xfRLTMode in xfRLTTable:
- onePlusOneRadioLinkProtectionAndEquipmentProtection
- twoPlusZeroRadioLinkBondingAndEquipmentProtection
- twoPlusTwoRadioLinkProtectionAndEquipmentProtection
- fourPlusZeroRadioLinkBondingAndEquipmentProtection
Added capability bits to xfRLTCapability in xfRLTTable:
- capTDM
- capCsPlurality
- capCtAutoSelection
- capOnePlusZero
- capOnePlusOneRadioLinkProtection
- capTwoPlusZeroAdvancedRadioLinkBonding
- capOnePlusOneRadioLinkProtectionWithEQP
- capTwoPlusZeroRadioLinkBondingWithEQP
- capTwoPlusTwoRadioLinkProtectionWithEQP
- capFourPlusZeroRadioLinkBondingWithEQP
"
REVISION "201709190000Z" -- 19 September 2017
DESCRIPTION
"
Rev PB19
- Type of MOs in table xfRLPMContinuousCounterTable changed to PerfCurrentCount/HCPerfCurrentCount.
- Removed MO xfRLTProtectionPMReset in table xfRLTProtectionTable.
"
REVISION "201708030000Z" -- 03 August 2017
DESCRIPTION
"
Rev PB18
Introduction in xfRLPMContinuousCounterTable of MOs:
- xfPMCurrentESR
- xfPMCurrentSESR
- xfPMCurrentBBER
"
REVISION "201705030000Z" -- 03 May 2017
DESCRIPTION
"
Rev. PB17
- Updated description for xfCarrierTermActualLicensedCapacity MO.
"
REVISION "201702010000Z" -- 01 February 2017
DESCRIPTION
"
Rev. PB16
- Added to xfCGIfAlarms the alarms:
* txSwitchover
* remoteTxSwitchOver
* unableToProtect
* rfInputThresholdProtection
"
REVISION "201701300000Z" -- 30 January 2017
DESCRIPTION
"
Rev. PB15
- Added the MOs xfRLTNumOfRLPSwitch and xfRLTProtectionPMReset in table xfRLTProtectionTable.
"
REVISION "201611040000Z" -- 04 November 2016
DESCRIPTION
"
Rev. PB14
- Added the MO xfRLTHighestSeverityAlarm in table xfRLTHierarchyModuleTable.
"
REVISION "201609290000Z" -- 29 September 2016
DESCRIPTION
"
Rev. PB13
- Added xfRLTProtectionTable.
- Move unused Protection MOs from xfRLTTable to xfRLTProtectionTable
"
REVISION "201609080000Z" -- 08 September 2016
DESCRIPTION
"
Rev. PB12
- Updated description for xfTDMMaxTributaries MO.
"
REVISION "201607180000Z" -- 18 July 2016
DESCRIPTION
"
Rev. PB11
- Updated description for xfPMPerfReset MO.
"
REVISION "201606100000Z" -- 10 June 2016
DESCRIPTION
"
Rev. PB10
- Added new table 'xfRLTHierarchyModuleTable'.
"
REVISION "201606060000Z" -- 06 June 2016
DESCRIPTION
"
Rev. PB9
- 'xfRLTCapability' and 'xfRLTInventoryLastChange' MOs added to 'xfRLTTable'.
"
REVISION "201606010000Z" -- 01 June 2016
DESCRIPTION
"
Rev. PB8
- Modified syntax for 'xfXPICCTmember1' and 'xfXPICCTmember2' MOs.
"
REVISION "201605020000Z" -- 02 May 2016
DESCRIPTION
"
Rev. PB7
- Added xfRLWANIfTable.
"
REVISION "201604290000Z" -- 29 April 2016
DESCRIPTION
"
Rev. PB6
- Changed enum for xfCGIfHopViewStatus MO.
"
REVISION "201604120000Z" -- 12 April 2016
DESCRIPTION
"
Rev. PB5
- Updated description for xfPMPerfReset MO.
- Updated description for xfCarrierTermActualCapacity MO.
- Updated description for xfRLTActualTXPacketCapacity MO.
- Extended list of possible values for xfRLTStatus MO.
"
REVISION "201603010000Z" -- 1 March 2016
DESCRIPTION
"
Rev. PB4
- Changed syntax for xfRLTManualSwitchCommand MO.
- NotApplicable value added to xfCarrierTermXPICOperStatus and xfCarrierTermMIMOOperStatus.
"
REVISION "201602220000Z" -- 22 February 2016
DESCRIPTION
"
Rev. PB2
- xfCarrierTermXPICOperStatus: added value 'testing'.
- xfRLTTxSwitchFarEnd MO renamed into xfRLTTxSwitchOverConfiguration
- xfRLTResetTxSwitchAlarm MO renamed into xfRLTTxSwitchOverAlarmReset, syntax changed.
- Description updated for some MOs.
"
REVISION "201602050000Z" -- 05 February 2016
DESCRIPTION
"
Rev. PB1
- Modified in xfCarrierTerminationCapabilityTable:
* xfACMProfile: removed non-XPIC / XPIC definition
* xfFrameFormatType: Standard definition added, other values updated
* xfChannelSpacing: added 60 MHz and 80 MHz for ANSI,
changed vaue for 112 MHz
- Modified in xfCarrierTerminationTable:
* xfCarrierTermXPICOperStatus: updated list of possible values
* xfCarrierTermMIMOOperStatus: updated list of possible values
* xfCarrierTermOperStatus: updated list of possible values
- Added in xfRLTTable:
* xfRLTManualSwitchCommand
* xfRLTTxSwitchFarEnd
* xfRLTResetTxSwitchAlarm
* xfRLTfeRltSeverity
- Added in xfRLTDMIfTable:
* xfTDMMaxTributaries
- Added in xfCGIfTable:
* xfCGIfHopViewStatus
- Added in xfCarrierTerminationTable:
* xfCarrierTermActualRxACM
* xfCarrierTermFeCTSeverity
- Added in xfXPICPairTable:
* xfXPICAutoRestore
"
REVISION "201511250000Z" -- 25 November 2015
DESCRIPTION
"
Rev. PA31
- Added RLT ID alarm in MO xfCGIfAlarms of xfCGIfTable.
- Range of xfCarrierTermWantedLicensedCapacity extended, it starts from 0 now (instead of 1).
- Value 'other' for xfCarrierTermPreamble renamed with 'notSpecified'.
- Value 'other' for xfCarrierTermReferenceSEC renamed with 'notSpecified'.
- Updated description for following objects:
* xfCarrierTermPreamble
* xfCarrierTermReferenceSEC
* xfCarrierTermBerAlarmThreshold
- Updated names and/or values list for following objects:
* xfRLTFarEndIdCheck
* xfTDMRxLoop
* xfTDMEnable
* xfXPICPairAdminStatus
* xfXPICPairRecovery
* xfMIMOGroupAdminStatus
* xfMIMOGroupRecovery
"
REVISION "201511160000Z" -- 16 November 2015
DESCRIPTION
"
Rev. PA30
Value 'other' for xfCarrierTermPolarization renamed with 'notSpecified'.
"
REVISION "201511100000Z" -- 10 November 2015
DESCRIPTION
"
Rev. PA29
Added status 'testing' to xfCarrierTermOperStatus object.
Size of xfTDMDistinguishedName object limited to 32 characters.
"
REVISION "201511050000Z" -- 05 November 2015
DESCRIPTION
"
Rev. PA28
Updated definition of xfPMACMStatus object in xfRLPMACMConfigTable.
"
REVISION "201509160000Z" -- 16 September 2015
DESCRIPTION
"
Rev. PA27
* Updated list of possible values for xfCarrierTermReferenceSEC object.
* Added RLT PM tables:
- xfRLPMContinuousCounterTable
- xfRLPMACMConfigTable
- xfRLPMACMCurrent24hTable
- xfRLPMACMInterval24hTable
- xfRLPMACMCurrent15mTable
- xfRLPMACMInterval15mTable
"
REVISION "201508270000Z" -- 27 August 2015
DESCRIPTION
"
Rev. PA26
* xfIfStatus object is read-only now.
* Changed names of possible values for xfTDMRxLoop object.
"
REVISION "201508200000Z" -- 20 August 2015
DESCRIPTION
"
Rev. PA25
* xfRadioChannelTable renamed into xfCarrierTerminationTable.
Overall review of table's objects, including renaming of *RadioChannel* into *CarrierTerm*.
Removed XPIC and MIMO related objects (but Oper Status).
* xfRadioChannelCapabilityTable renamed into xfCarrierTerminationCapabilityTable.
* xfRLTTable added:
- xfRLTReset
- xfRLTFadeNotificationTimer
* xfXPICPairTable added:
- xfXPICPairRecovery
- xfXPICPairRestore
* xfMIMOGroupTable added:
- xfMIMOGroupRecovery
- xfMIMOGroupRestore
* xfRLTDMIfTable added:
- xfTDMDistinguishedName
- xfTDMRxLoop
"
REVISION "201507070000Z" -- 7 July 2015
DESCRIPTION
"
Rev. PA24
* Modified RLT table.
* Added xfXPICPairTable.
* Added xfMIMOGroupTable.
"
REVISION "201506300000Z" -- 30 June 2015
DESCRIPTION
"
Rev. PA23
Added chsp112MHz value to xfChannelSpacing object.
"
REVISION "201506040000Z" -- 04 June 2015
DESCRIPTION
"
Rev. PA22
Added second index, liIfIndex, in xfLIMappingtable.
"
REVISION "201506030000Z" -- 03 June 2015
DESCRIPTION
"
Rev. PA21
Removed xfWantedTDMCapacity in xfRLTDMIfTable.
"
REVISION "201505110000Z" -- 11 May 2015
DESCRIPTION
"
Rev. PA20
Added xfCGIfIndex to xfCGIfTable.
"
REVISION "201505080000Z" -- 8 May 2015
DESCRIPTION
"
Rev. PA19
Added xfCGIfTable.
"
REVISION "201505060000Z" -- 6 May 2015
DESCRIPTION
"
Rev. PA18
Removed:
xfRLTDMIfTable xfTDMAllocation
Added:
xfRLTDMIfTable xfWantedTDMAllocation
xfActualTDMAllocation
"
REVISION "201504200000Z" -- 20 April 2015
DESCRIPTION
"
Rev. PA17
Removed rcEntLogicalIndex in xfRadioChannelTable.
"
REVISION "201504130000Z" -- 13 April 2015
DESCRIPTION
"
Rev. PA16
Removed xfRLWANIfTable.
"
REVISION "201503300000Z" -- 30 March 2015
DESCRIPTION
"
Rev. PA15
Changed type for xfACMIndex object in xfACMProfileCapacityTable.
"
REVISION "201503190000Z" -- 19 March 2015
DESCRIPTION
"
Rev. PA14
* xfRLTDMIfIndex object added in xfRLTDMIfTable.
* xfRLWANIfIndex object added in xfRLWANIfTable.
* Changed names of values for xfACMProfile object.
* Changed type from Integer32 to RadioChannelACMIndex for objects
- xfRadioChannelMinACMIndex
- xfRadioChannelActualACMIndex
- xfRadioChannelMaxACMIndex
"
REVISION "201503110000Z" -- 11 March 2015
DESCRIPTION
"
Rev. PA13
xfRadioChannelBerAlarmThresholdCapability object removed.
"
REVISION "201503090000Z" -- 09 March 2015
DESCRIPTION
"
Rev. PA12
* xfRadioFrameType changed to xfFrameFormatType.
* xfACMMinCapacity changed to xfMinACMCapacity.
* xfACMMaxCapacity changed to xfMaxACMCapacity.
"
REVISION "201503060000Z" -- 06 March 2015
DESCRIPTION
"
Rev. PA11
* cgIfDescr changed to cgTypeIndex.
* Minor adjustments to avoid sintax check warning.
"
REVISION "201503050000Z" -- 05 March 2015
DESCRIPTION
"
Rev. PA10
* Adjustements to objects in xfRadioChannelTable.
- Descriptions updated.
- For enumerative objects, value (1) is always used for 'other'.
* xfRadioLinkRltConformance added.
"
REVISION "201502250000Z" -- 25 February 2015
DESCRIPTION
"
Rev. PA9
* <xfChannel> changed to <xfRadioChannel> for all applicable objects and tables.
* Removed object <xfRadioChannelSpectrumEfficiencyClassCapability>.
* Wrong spelling corrected: xfChanneMinACMIndex --> xfRadioChannelMinACMIndex.
* Changed objects names:
xfRadioChannelStatus -> xfRadioChannelOperStatus
xfXPICOper --> xfXPICAdminStatus
xfXPICStatus --> xfXPICOperStatus
xfMIMOOper --> xfMIMOAdminStatus
xfMIMOStatus --> xfIMIMOOperStatus
xfXPICPaired --> xfXPICRadioChannelPaired
xfMIMOPaired --> xfMIMORadioChannelPaired
xfRCPreamble --> xfRadioChannelPreamble
xfChannelMSELevel --> xfMSELevel
* Added new objects:
xfXPICRestore
xfMIMORestore
xfRadioChannelRestore
xfRadioChannelAutoRemoveLoopEnable
xfRadioChannelBerAlarmThreshold
"
REVISION "201502180000Z" -- 18 February 2015
DESCRIPTION
"
Rev. PA8
XfRadioChannelTable:
Changed:
xfXPICMIMORecovery --> xfXPICRecovery
xfXPICMIMOPaired --> xfXPICPaired
Added:
xfMIMORecovery
xfMIMOPaired
xfRLTTable
Changed:
xfActualCapacity --> xfRLTActualCapacity
"
REVISION "201502100000Z" -- 10 February 2015
DESCRIPTION
"
Rev. PA7
Added:
xfSelectedFrameID MO in xfRadioChannelTable
Changed:
xfXPICMIMOPaired to R-W
"
REVISION "201501290000Z" -- 29 January 2015
DESCRIPTION
"
Rev. PA6
Added:
xfACMProfileCapacityTable
Modified:
xfChannelCapabilityTable - added the following MOs:
xfRadioFrameType
xfACMMinCapacity
xfACMMaxCapacity
xfACMProfile
"
REVISION "201412120000Z" -- 12 December 2014
DESCRIPTION
"
Rev. PA5
Removed:
xfRadioChannelTable: xfRadioChannelName
Added:
xfRadioChannelTable: xfRadioChannelStatus
xfXPICOper
xfMIMOOper
xfXPICMIMORecovery
xfXPICMIMOPaired
xfRCPreamble
xfRLTDMIfTable xfTDMAllocation
xfRLWANIfTable xfWANMinSpeed
xfMaxMaxSpeed
"
REVISION "201412100000Z" -- 10 December 2014
DESCRIPTION
"
Rev. PA4
Minor change to compile with Wind River compiler.
"
REVISION "201412020000Z" -- 02 December 2014
DESCRIPTION
"
Rev. PA3
Table removed: xfRadioLinkRltTable
Table renamed: xfRadioChannelMappingTable --> xfRadioChannelTable
xfRLTTerminalTable --> xfRLTTable,
xfRLLogicalToIfTable --> xfLIMappingTable
Table added: xfChannelGroupTable, xfTrafficTable,
xfRLTDMIfTable, xfRLWANIfTable.
Object value removed: equipmentProtection in ChannelGroupType
Changed ifName to ifIndex in xfChannelGroupTable index
Changed ifName to ifIndex in xfLIMappingTable and removed ifIndex as table index
Added in:
xfLIMappingTable the MOs: xfLIName
xfLIIfDescr
xfRadioChannelTable the MOs: xfRadioChannelID
xfChanneMinRowIndex
xfChannelActualRowIndex
xfChannelMaxRowIndex
xfChannelCapabilitiesLastChange
xfChannelSpectrumEfficiencyClass
xfChannelSpectrumEfficiencyClassCapability
xfChannelActualCapacity
xfChannelCapacityLicense
xfXPICStatus
xfMIMOStatus
xfXPILevel
xfChannelMSELevel
"
REVISION "201412010000Z" -- 01 December 2014
DESCRIPTION
"
Rev. PA2
Table added: xfRadioLinkRltTable, xfRLLogicalToIfTable
xfRadioChannelMappingTable, xfRLTTerminalTable.
"
REVISION "201411110000Z" -- 11 November 2014
DESCRIPTION
"
Rev. PA1
Initial revision.
"
::= { xfRadioLink 5 }
--
-- Textual conventions
--
CarrierTermACMIndex ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This TC enumerates all possible ACM index values."
SYNTAX INTEGER
{
acm4QAMStrong(1),
acm4QAMStd(2),
acm4QAMLight(3),
acm16QAMStrong(4),
acm16QAMStd(5),
acm16QAMLight(6),
acm32QAMStrong(7),
acm32QAMStd(8),
acm32QAMLight(9),
acm64QAMStrong(10),
acm64QAMStd(11),
acm64QAMLight(12),
acm128QAMStrong(13),
acm128QAMStd(14),
acm128QAMLight(15),
acm256QAMStrong(16),
acm256QAMStd(17),
acm256QAMLight(18),
acm512QAMStrong(19),
acm512QAMStd(20),
acm512QAMLight(21),
acm1024QAMStrong(22),
acm1024QAMStd(23),
acm1024QAMLight(24),
acm2048QAMStrong(25),
acm2048QAMStd(26),
acm2048QAMLight(27),
acm4096QAMStrong(28),
acm4096QAMStd(29),
acm4096QAMLight(30),
acm8192QAMStrong(31),
acm8192QAMStd(32),
acm8192QAMLight(33),
acm16384QAMStrong(34),
acm16384QAMStd(35),
acm16384QAMLight(36)
}
--
-- Node definitions
--
xfRadioLinkRltObjects OBJECT IDENTIFIER
::= { xfRadioLinkRltMIB 1 }
xfRadioLinkRltPmObjects OBJECT IDENTIFIER
::= { xfRadioLinkRltMIB 2 }
xfRadioLinkRltConformance OBJECT IDENTIFIER
::= { xfRadioLinkRltMIB 3 }
--
------------------------------------------------------------------------------
-- xfRadioLinkRltObjects
------------------------------------------------------------------------------
-- The xfRadioLinkRltObjects MOs
------------------------------------------------------------------------------
-- xfChannelGroupTable
------------------------------------------------------------------------------
xfChannelGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfChannelGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists all relationships, for ech Channel Group (CG), between the Bonding/RLP interface
and the RL WAN interface and allows to configure CG as either Bonding or Radio Link protection (RLP)."
::= { xfRadioLinkRltObjects 1 }
xfChannelGroupEntry OBJECT-TYPE
SYNTAX XfChannelGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfChannelGroupTable."
INDEX { cgIfIndex, cgTypeIndex }
::= { xfChannelGroupTable 1 }
XfChannelGroupEntry ::=
SEQUENCE
{
cgIfIndex Integer32,
cgTypeIndex INTEGER,
xfIfStatus INTEGER
}
cgIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It is the ifIndex of WAN interface.
The interface identified by atIfIndex is the same
interface as identified by the same value of ifIndex."
::= { xfChannelGroupEntry 1 }
cgTypeIndex OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
bonding(2),
rlp(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index representing the Channel Group interface type:
- Bonding (2)
- RLP: Radio Link Protection (3)"
::= { xfChannelGroupEntry 2 }
xfIfStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
ready(2),
notReady(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the Channel Group interface type:
either Bonding or RLP (Radio Link Protection).
Default: notReady"
::= { xfChannelGroupEntry 3 }
------------------------------------------------------------------------------
-- xfLIMappingTable
------------------------------------------------------------------------------
xfLIMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfLIMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used when navigating from a logical entity to interface,
representing the relationship between:
- RLT logical entity and either Bonding/RLP interface;
- Carrier Termination (CT) logical entity and RAU IF interface."
::= { xfRadioLinkRltObjects 2 }
xfLIMappingEntry OBJECT-TYPE
SYNTAX XfLIMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfLIMappingTable."
INDEX { liEntLogicalIndex, liIfIndex }
::= { xfLIMappingTable 1 }
XfLIMappingEntry ::=
SEQUENCE
{
liEntLogicalIndex Integer32,
liIfIndex Integer32,
xfLIName DisplayString,
xfLIIfDescr DisplayString
}
liEntLogicalIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object uniquely identifies the logical
entity: RLT (Radio Link Terminal) and CT (Carrier Termination).
The logical entity identified by liEntLogicalIndex is the same
interface as identified by the same value of entLogicalIndex."
::= { xfLIMappingEntry 1 }
liIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the ifIndex of Bonding/RLP interface and RAU IF.
The interface identified by liIfIndex is the same
interface as identified by the same value of ifIndex."
::= { xfLIMappingEntry 2 }
xfLIName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the Name of the Radio Link Terminal (RLT) or Carrier Termination (CT)."
::= { xfLIMappingEntry 3 }
xfLIIfDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing information about the ifDescr of both
Channel Group interface (either Bonding or RLP (Radio Link Protection))
and RAU IF interface."
::= { xfLIMappingEntry 4 }
------------------------------------------------------------------------------
-- xfCarrierTerminationTable
------------------------------------------------------------------------------
xfCarrierTerminationTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfCarrierTerminationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure the Carrier Termination (CT)."
::= { xfRadioLinkRltObjects 3 }
xfCarrierTerminationEntry OBJECT-TYPE
SYNTAX XfCarrierTerminationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfCarrierTerminationTable."
INDEX { entLogicalIndex }
::= { xfCarrierTerminationTable 1 }
XfCarrierTerminationEntry ::=
SEQUENCE
{
xfCarrierTermDistinguishedName DisplayString,
xfCarrierTermLabel DisplayString,
xfCarrierTermOperStatus INTEGER,
xfCarrierTermRadioFrameId Integer32,
xfCarrierTermPreamble INTEGER,
xfCarrierTermSelectedMinACM CarrierTermACMIndex,
xfCarrierTermActualACM CarrierTermACMIndex,
xfCarrierTermSelectedMaxACM CarrierTermACMIndex,
xfCarrierTermCapabilitiesLastChange TimeTicks,
xfCarrierTermReferenceSEC INTEGER,
xfCarrierTermWantedLicensedCapacity Integer32,
xfCarrierTermActualLicensedCapacity Integer32,
xfCarrierTermActualCapacity Integer32,
xfCarrierTermPolarization INTEGER,
xfCarrierTermXPICOperStatus INTEGER,
xfCarrierTermMIMOOperStatus INTEGER,
xfCarrierTermSNIR Integer32,
xfCarrierTermXPI Integer32,
xfCarrierTermReset INTEGER,
xfCarrierTermRestore INTEGER,
xfCarrierTermAutoRemoveLoopEnable INTEGER,
xfCarrierTermBerAlarmThreshold INTEGER,
xfCarrierTermActualRxACM CarrierTermACMIndex,
xfCarrierTermFeCTSeverity BITS
}
xfCarrierTermDistinguishedName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the distinguished name of the Carrier Termination in the format Rack/Slot/CT."
::= { xfCarrierTerminationEntry 1 }
xfCarrierTermLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Label identifying the Carrier Termination.
It can be freely set by operator to label the Carrier Termination."
::= { xfCarrierTerminationEntry 2 }
xfCarrierTermOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
down(2),
up(3),
degraded(4),
testing(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the operative status of the Carrier Termination:
- down(2)
- up(3)
- degraded(4)
- testing(5)"
::= { xfCarrierTerminationEntry 3 }
xfCarrierTermRadioFrameId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It represents the selected Radio Frame ID."
::= { xfCarrierTerminationEntry 4 }
xfCarrierTermPreamble OBJECT-TYPE
SYNTAX INTEGER
{
notSpecified(1),
preambleA(2),
preambleB(3),
preambleC(4),
preambleD(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It allows to set different preambles in the radio frame
of each Carrier Termination in a XPIC or MIMO configuration:
- preambleA(2)
- preambleB(3)
- preambleC(4)
- preambleD(5)
For non XPIC nor MIMO configurations, it can be left to notSpecified(1)."
::= { xfCarrierTerminationEntry 5 }
xfCarrierTermSelectedMinACM OBJECT-TYPE
SYNTAX CarrierTermACMIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It represents the selected minimum Tx ACM (Adaptive Code Modulation)."
::= { xfCarrierTerminationEntry 6 }
xfCarrierTermActualACM OBJECT-TYPE
SYNTAX CarrierTermACMIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the actual (current) Tx ACM (Adaptive Code Modulation)."
::= { xfCarrierTerminationEntry 7 }
xfCarrierTermSelectedMaxACM OBJECT-TYPE
SYNTAX CarrierTermACMIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It represents the selected maximum Tx ACM (Adaptive Code Modulation)."
::= { xfCarrierTerminationEntry 8 }
xfCarrierTermCapabilitiesLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time of the last creation or
deletion of an entry in the xfCarrierTerminationCapabilityTable.
If the number of entries has been unchanged since the last
re-initialization of the local network management subsystem,
then this object contains a zero value."
::= { xfCarrierTerminationEntry 9 }
xfCarrierTermReferenceSEC OBJECT-TYPE
SYNTAX INTEGER
{
notSpecified(1),
sec2(2),
sec4L(3),
sec4H(4),
sec5LB(5),
sec5HB(6),
sec6LB(7),
sec6HB(8),
sec7B(9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reference Spectrum Efficiency Class (SEC):
- notSpecified(1): not configured, not possible to set
- sec2(2): spectrum eff. Class 2
- sec4L(3): spectrum eff. Class 4L
- sec4H(4): specturm eff. Class 4H
- sec5LB(5): spectrum eff. Class 5LB
- sec5HB(6): spectrum eff. Class 5HB
- sec6LB(7): spectrum eff. Class 6LB
- sec6HB(8): spectrum eff. Class 6HB
- sec7B(9): spectrum eff. Class 7B
In ETSI, a value different from notSpecified(1) must be configured.
In ANSI, no value can be set and notSpecified(1) is always returned.
Near end access: read-write.
Far end access: read-write."
::= { xfCarrierTerminationEntry 10 }
xfCarrierTermWantedLicensedCapacity OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It represents the wanted traffic licensed capacity on the Carrier Termination, expressed in Kbps.
The default value 0 (i.e. disabled) means that no wanted licensed capacity has been selected by the user.
The value used by RL license logic to request capacity licenses for the Carrier Termination is:
- the capacity of selected max profile, if xfCarrierTermWantedLicensedCapacity = 0
- the value of xfCarrierTermWantedLicensedCapacity itself, if it is different from 0
"
::= { xfCarrierTerminationEntry 11 }
xfCarrierTermActualLicensedCapacity OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This MO represents the Actual Licensed Capacity used on the Carrier Termination:
- if Wanted Licensed Capacity is disabled (i.e. xfCarrierTermWantedLicensedCapacity = 0),
the Selected Max ACM (xfCarrierTermSelectedMaxACM MO) is used for requesting the license capacity on the carrier;
- if Wanted Licensed Capacity is enabled (i.e. xfCarrierTermWantedLicensedCapacity > 0),
the value of Wanted Licensed Capacity itself is used for requesting the license capacity on the carrier.
"
::= { xfCarrierTerminationEntry 12 }
xfCarrierTermActualCapacity OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the actual transmitted capacity supported by Carrier Termination in Kbps."
::= { xfCarrierTerminationEntry 13 }
xfCarrierTermPolarization OBJECT-TYPE
SYNTAX INTEGER
{
notSpecified(1),
horizontal(2),
vertical(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"XPIC polarization, either horizontal or vertical."
::= { xfCarrierTerminationEntry 14 }
xfCarrierTermXPICOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
locked(2),
unlocked(3),
mute(4),
notApplicable(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"XPIC locking status:
- Other(1): don't use
- Locked(2): XPIC is locked: XPI valid
- Unlocked(3): XPIC is not locked: XPI not valid
- Mute(4): XPIC is muted (XPIC recovery started)
- NotApplicable(5): XPIC is disabled"
::= { xfCarrierTerminationEntry 15 }
xfCarrierTermMIMOOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
locked(2),
unlocked(3),
mute(4),
notApplicable(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MIMO locking status:
- Other(1): don't use
- Locked(2): MIMO is locked: XPI and SNIR valid
- Unlocked(3): MIMO is not locked: XPI and SNIR not valid
- Mute(4): MIMO is muted
- NotApplicable(5): MIMO is disabled"
::= { xfCarrierTerminationEntry 16 }
xfCarrierTermSNIR OBJECT-TYPE
SYNTAX Integer32 --(-1000..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal to Noise Interference Ratio (SNIR) in dB."
::= { xfCarrierTerminationEntry 17 }
xfCarrierTermXPI OBJECT-TYPE
SYNTAX Integer32 --(-1000..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cross-Polar Interference (XPI) level of the receiver in tenth of dB."
::= { xfCarrierTerminationEntry 18 }
xfCarrierTermReset OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
noReset(2),
reset(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset command forces all the Carrier Termination settings
to their own default."
::= { xfCarrierTerminationEntry 19 }
xfCarrierTermRestore OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
noRestore(2),
restore(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Restore command clears RFloop, IFloop and turns RAU transmitter on."
::= { xfCarrierTerminationEntry 20 }
xfCarrierTermAutoRemoveLoopEnable OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
disabled(2),
enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Auto remove all RL loops after 15 minutes."
::= { xfCarrierTerminationEntry 21 }
xfCarrierTermBerAlarmThreshold OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
ber1e3(2),
ber1e4(3),
ber1e5(4),
ber1e6(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold for BER alarm.
Default: ber1e3(2)."
::= { xfCarrierTerminationEntry 22 }
xfCarrierTermActualRxACM OBJECT-TYPE
SYNTAX CarrierTermACMIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the actual (current) Rx ACM (Adaptive Code Modulation)."
::= { xfCarrierTerminationEntry 23 }
xfCarrierTermFeCTSeverity OBJECT-TYPE
SYNTAX BITS
{
feCtSeverity0(0),
feCtSeverity1(1),
feCtSeverity2(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This object represents the highest severity of Far-End CT alarms and is populated only if Far-End terminal is
represented by a Packet terminal (PT). Craft uses this MO to colour the box representing the Far-End CT
in the hop view.
In case of the Far-End is a TN, the remote highest alarm severity of CT is referred to the interfaces:
RAU IF and RF IF.
"
::= { xfCarrierTerminationEntry 24 }
------------------------------------------------------------------------------
-- xfCarrierTerminationCapabilityTable
------------------------------------------------------------------------------
xfCarrierTerminationCapabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfCarrierTerminationCapabilityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure the Carrier Termination (CT)."
::= { xfRadioLinkRltObjects 4 }
xfCarrierTerminationCapabilityEntry OBJECT-TYPE
SYNTAX XfCarrierTerminationCapabilityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfCarrierTerminationCapabilityTable."
INDEX { entLogicalIndex, xfRadioFrameId }
::= { xfCarrierTerminationCapabilityTable 1 }
XfCarrierTerminationCapabilityEntry ::=
SEQUENCE
{
xfRadioFrameId Integer32,
xfChannelSpacing INTEGER,
xfFrameFormatType INTEGER,
xfMinACMCapacity Integer32,
xfMaxACMCapacity Integer32,
xfACMProfile BITS
}
xfRadioFrameId OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the Radio Frame Id."
::= { xfCarrierTerminationCapabilityEntry 1 }
xfChannelSpacing OBJECT-TYPE
SYNTAX INTEGER
{
chspOther(1),
chsp3500kHz(2),
chsp7MHz(3),
chsp10MHz(4),
chsp14MHz(5),
chsp20MHz(6),
chsp28MHz(7),
chsp30MHz(8),
chsp40MHz(9),
chsp50MHz(10),
chsp56MHz(11),
chsp60MHz(12),
chsp80MHz(13),
chsp112MHz(14)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Channel spacing:
- ETSI: 3.5, 7, 14, 28, 40, 56, 112 MHz
- ANSI: 10, 20, 30, 40, 50, 60, 80 MHz"
::= { xfCarrierTerminationCapabilityEntry 2 }
xfFrameFormatType OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
standard(2),
xpic(3),
mimo(4),
longHaulStandard(5),
longHaulXpic(6),
xpic2boards(7),
longHaulXpic2boards(8),
mimo2boards(9),
sisoCA(10),
xpicCA(11)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the Frame Format type:
- Standard
- XPIC
- MIMO
- Long Haul Standard
- Long Haul XPIC
- XPIC on two boards
- Long Haul XPIC on two boards
"
::= { xfCarrierTerminationCapabilityEntry 3 }
xfMinACMCapacity OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the minimum capacity designed for the specific frame format (Radio Frame Id)."
::= { xfCarrierTerminationCapabilityEntry 4 }
xfMaxACMCapacity OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the maximum capacity designed for the frame format (Radio Frame Id)."
::= { xfCarrierTerminationCapabilityEntry 5 }
xfACMProfile OBJECT-TYPE
SYNTAX BITS
{
none(0),
qam4Strong(1),
qam4Std(2),
qam4Light(3),
qam16Strong(4),
qam16Std(5),
qam16Light(6),
qam32Strong(7),
qam32Std(8),
qam32Light(9),
qam64Strong(10),
qam64Std(11),
qam64Light(12),
qam128Strong(13),
qam128Std(14),
qam128Light(15),
qam256Strong(16),
qam256Std(17),
qam256Light(18),
qam512Strong(19),
qam512Std(20),
qam512Light(21),
qam1024Strong(22),
qam1024Std(23),
qam1024Light(24),
qam2048Strong(25),
qam2048Std(26),
qam2048Light(27),
qam4096Strong(28),
qam4096Std(29),
qam4096Light(30),
qam8192Strong(31),
qam8192Std(32),
qam8192Light(33),
qam16384Strong(34),
qam16384Std(35),
qam16384Light(36)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It specifies which adaptive code and modulation profiles are supported."
::= { xfCarrierTerminationCapabilityEntry 6 }
----------------------------------------------------------------------------
-- xfACMProfileCapacityTable
----------------------------------------------------------------------------
xfACMProfileCapacityTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfACMProfileCapacityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This tables reports the ACM capacities of the selected Radio Frame Id per each Carrier Termination."
::= { xfRadioLinkRltObjects 5 }
xfACMProfileCapacityEntry OBJECT-TYPE
SYNTAX XfACMProfileCapacityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfACMProfileCapacityTable."
INDEX { entLogicalIndex, xfACMIndex }
::= { xfACMProfileCapacityTable 1 }
XfACMProfileCapacityEntry ::=
SEQUENCE
{
xfACMIndex CarrierTermACMIndex,
xfACMCapacity Integer32
}
xfACMIndex OBJECT-TYPE
SYNTAX CarrierTermACMIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the positional index of the bitmap xfACMProfile in xfCarrierTerminationCapabilityTable."
::= { xfACMProfileCapacityEntry 1 }
xfACMCapacity OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the capacity in Kbps of the ACM profile identified by the positional index
xfACMIndex of the xfACMProfile in xfCarrierTerminationCapabilityTable.
Value 0 means that the ACM profile is not included in current Frame Format."
::= { xfACMProfileCapacityEntry 2 }
------------------------------------------------------------------------------
-- xfRLTTable
------------------------------------------------------------------------------
xfRLTTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLTEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to configure the Radio Link Terminal (RLT)."
::= { xfRadioLinkRltObjects 6 }
xfRLTEntry OBJECT-TYPE
SYNTAX XfRLTEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfRLTTable."
INDEX { rltEntLogicalIndex }
::= { xfRLTTable 1 }
XfRLTEntry ::=
SEQUENCE
{
rltEntLogicalIndex Integer32,
xfRLTDistinguishedName DisplayString,
xfRLTIpAddress IpAddress,
xfRLTIPv6Address InetAddressIPv6,
xfRLTNeName DisplayString,
xfRLTNeType DisplayString,
xfRLTId DisplayString,
xfRLTExpectedFarEndId DisplayString,
xfRLTFarEndIdCheck INTEGER,
xfRLTStatus INTEGER,
xfRLTMode INTEGER,
xfRLTActualTXTotalCapacity Gauge32,
xfRLTActualTXPacketCapacity Gauge32,
xfRLTLimitedTotalCapacity Gauge32,
xfRLTRltSeverity BITS,
xfRLTCapability BITS,
xfRLTInventoryLastChange TimeTicks,
xfRLTCpriMode INTEGER,
xfRLTReset INTEGER,
xfRLTMeasuredHopLength INTEGER
}
rltEntLogicalIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the entLogicalIndex of the Radio Link Terminal (RLT).
The logical entity identified by rltEntLogicalIndex is the same
entity as identified by the same value of entLogicalIndex."
::= { xfRLTEntry 1 }
xfRLTDistinguishedName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the distinguished name of the Radio Link Terminal (RLT): Rack/Slot/RLT number.
It is the ifName of RL-WAN i/f."
::= { xfRLTEntry 2 }
xfRLTIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IPv4 address of the network element the Radio Link Terminal (RLT) belongs to."
::= { xfRLTEntry 3 }
xfRLTIPv6Address OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IPv6 Address of the network element the Radio Link Terminal (RLT) belongs to."
::= { xfRLTEntry 4 }
xfRLTNeName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the network element the Radio Link Terminal (RLT) belongs to (System Name - sysName)."
::= { xfRLTEntry 5 }
xfRLTNeType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the network element the Radio Link Terminal (RLT) belongs to (System Descr - sysDescr)."
::= { xfRLTEntry 6 }
xfRLTId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Radio Link Terminal (RLT) identifier used for integrity check with far-end."
::= { xfRLTEntry 7 }
xfRLTExpectedFarEndId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Expected Id of far-end Radio Link Terminal (RLT), used for integrity check with near-end."
::= { xfRLTEntry 8 }
xfRLTFarEndIdCheck OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
enable(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled, the system verifies that far-end Radio Link Terminal name is equal to the expected.
If ok Radio Link Terminal status is UP. If not ok the Radio Link Terminal status is stated as DOWN.
Default value: disabled.
"
::= { xfRLTEntry 9 }
xfRLTStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
down(2),
up(3),
degraded(4),
resourceUnavailable(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the operational status of the Radio Link Terminal (RLT)."
::= { xfRLTEntry 10 }
xfRLTMode OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
onePlusZero(2),
onePlusOneRadioLinkProtection(3),
twoPlusZeroAdvancedRadioLinkBonding(4),
onePlusOneRadioLinkProtectionAndEquipmentProtection(5),
twoPlusZeroRadioLinkBondingAndEquipmentProtection(6),
twoPlusTwoRadioLinkProtectionAndEquipmentProtection(7),
fourPlusZeroRadioLinkBondingAndEquipmentProtection(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mode of the Radio Link Terminal (RLT).
Values:
- 1+0: onePlusZero (default)
- 1+1 RLP: onePlusOneRadioLinkProtection
- 2+0 RLB: twoPlusZeroAdvancedRadioLinkBonding
- 1+1 RLP EQP: onePlusOneRadioLinkProtectionAndEquipmentProtection
- 2+0 RLB EQP: twoPlusZeroRadioLinkBondingAndEquipmentProtection
- 2+2 RLP EQP: twoPlusTwoRadioLinkProtectionAndEquipmentProtection
- 4+0 RLB EQP: fourPlusZeroRadioLinkBondingAndEquipmentProtection
"
::= { xfRLTEntry 11 }
xfRLTActualTXTotalCapacity OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
It represents the total transmitted capacity throughput (considering both Packet and TDM traffic),
expressed in bps, of the Radio Link Terminal (RLT).
"
::= { xfRLTEntry 12 }
xfRLTActualTXPacketCapacity OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
It represents the transmitted packet capacity throughput (only packet traffic),
expressed in bps, of the Radio Link Terminal (RLT).
"
::= { xfRLTEntry 13 }
xfRLTLimitedTotalCapacity OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
It represents the total transmitted capacity throughput (considering both Packet and TDM traffic),
expressed in bps, of the Radio Link Terminal (RLT) limited by License.
"
::= { xfRLTEntry 14 }
xfRLTRltSeverity OBJECT-TYPE
SYNTAX BITS
{
rltSeverity0(0),
rltSeverity1(1),
rltSeverity2(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This object represents the highest severity alarm related to RLT with logical index 'rltEntLogicalIndex'.
Node GUI uses the Far-End entry value (of this MIB MO) to define the colour of the Far-End RLT box in the hop view.
"
::= { xfRLTEntry 15 }
xfRLTCapability OBJECT-TYPE
SYNTAX BITS
{
xpicCapability0(0),
capTDMWithEQP(1),
capCsPlurality(2),
capCtAutoSelection(3),
capOnePlusZero(4),
capOnePlusOneRadioLinkProtection(5),
capTwoPlusZeroAdvancedRadioLinkBonding(6),
capOnePlusOneRadioLinkProtectionWithEQP(7),
capTwoPlusZeroRadioLinkBondingWithEQP(8),
capTwoPlusTwoRadioLinkProtectionWithEQP(9),
capFourPlusZeroRadioLinkBondingWithEQP(10),
capXpicBetweenBoards(11),
capXpicMembersAutoSelection(12),
capManualEqpSwitch(13),
capEnhAcmMaxCapacity(14),
capEnhAcmMaxProtection(15),
capRLEncryption(16),
capMIMO(17),
capTXswoAndSSD(18)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Each bit of this object represents an RLT capability:
Bit 0 - XPIC capability
Bit 1 - TDM capability
Bit 2 - CsPlurality capability
Bit 3 - CtAutoSelection capability
Bit 4 - OnePlusZero capability
Bit 5 - OnePlusOneRadioLinkProtection capability
Bit 6 - TwoPlusZeroAdvancedRadioLinkBonding capability
Bit 7 - OnePlusOneRadioLinkProtectionWithEQP capability
Bit 8 - TwoPlusZeroRadioLinkBondingWithEQP capability
Bit 9 - TwoPlusTwoRadioLinkProtectionWithEQP capability
Bit 10 - FourPlusZeroRadioLinkBondingWithEQP capability
Bit 11 - XPIC between boards capability
Bit 12 - XPIC Members Auto Selection capability
Bit 13 - Manual EQP Switch capability
Bit 14 - Enhanced ACM Protection: Maximum Capacity capability
Bit 15 - Enhanced ACM Protection: Maximum Protection capability
Bit 16 - Radio Link Encryption capability
Bit 17 - MIMO capability
Bit 18 - TX swicthover and SSD capability
"
::= { xfRLTEntry 16 }
xfRLTInventoryLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
The value of sysUpTime at the time of the last creation or
deletion of an entry in the xfRLTHierarchyModuleTable.
If the current state was entered prior to the last
re-initialization of the local network management subsystem,
then this object contains a zero value.
"
::= { xfRLTEntry 17 }
xfRLTCpriMode OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Set the mode of the CPRI front-haul product.
Default: notApplicable."
::= { xfRLTEntry 18 }
xfRLTReset OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
rltNoReset(2),
rltReset(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It resets RLT to default configuration."
::= { xfRLTEntry 19 }
xfRLTMeasuredHopLength OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the measured value of the radio hop length expressed in Km.
Values:
- Radio hop length measurement not yet available: -1;
- Measured hop length in Km: > 0.
"
::= { xfRLTEntry 20 }
------------------------------------------------------------------------------
-- xfTrafficTable
------------------------------------------------------------------------------
xfTrafficTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to map the TDM interface to the specified RLT."
::= { xfRadioLinkRltObjects 7 }
xfTrafficEntry OBJECT-TYPE
SYNTAX XfTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfTrafficEntry."
INDEX { trEntLogicalIndex }
::= { xfTrafficTable 1 }
XfTrafficEntry ::=
SEQUENCE
{
trEntLogicalIndex Integer32,
xfTDMEnable INTEGER
}
trEntLogicalIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the entLogicalIndex of the Radio Link Terminal (RLT).
The logical entity identified by trEntLogicalIndex is the same
interface as identified by the same value of entLogicalIndex."
::= { xfTrafficEntry 1 }
xfTDMEnable OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
enable(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It allows to map TDM interface to a specific Radio Link Terminal (RLT).
Default: disable."
::= { xfTrafficEntry 2 }
------------------------------------------------------------------------------
-- xfRLTDMIfTable
------------------------------------------------------------------------------
xfRLTDMIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLTDMIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extention of the ifTable used to configure TDM interface."
::= { xfRadioLinkRltObjects 8 }
xfRLTDMIfEntry OBJECT-TYPE
SYNTAX XfRLTDMIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfRLTDMIfEntry."
INDEX { xfRLTDMIfIndex }
::= { xfRLTDMIfTable 1 }
XfRLTDMIfEntry ::=
SEQUENCE
{
xfRLTDMIfIndex Integer32,
xfActualTDMCapacity Integer32,
xfWantedTDMAllocation BITS,
xfActualTDMAllocation BITS,
xfTDMIfAlarms BITS,
xfTDMRxLoop INTEGER,
xfTDMDistinguishedName DisplayString,
xfTDMMaxTributaries INTEGER,
xfTDMHopLength INTEGER
}
xfRLTDMIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It is the ifIndex of RL TDM I/F table."
::= { xfRLTDMIfEntry 1 }
xfActualTDMCapacity OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the current tributary capacity."
::= { xfRLTDMIfEntry 2 }
xfWantedTDMAllocation OBJECT-TYPE
SYNTAX BITS { firstE1(0) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It represents the wanted tributary allocation."
::= { xfRLTDMIfEntry 3 }
xfActualTDMAllocation OBJECT-TYPE
SYNTAX BITS { firstE1(0) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the actual tributary allocation."
::= { xfRLTDMIfEntry 4 }
xfTDMIfAlarms OBJECT-TYPE
SYNTAX BITS
{
ber0(0),
ber1(1),
ber2(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows TDM if related alarms."
::= { xfRLTDMIfEntry 5 }
xfTDMRxLoop OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
enable(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It configures TDM RX loop:
- other(1)
- enable(2)
- disable(3) (default)
"
::= { xfRLTDMIfEntry 6 }
xfTDMDistinguishedName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It is the disinguished name of TDM i/f, i.e. R/S/P."
::= { xfRLTDMIfEntry 7 }
xfTDMMaxTributaries OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the maximum number of tributaries that can be allocated to TDM i/f,
depending on frame ID, minimum ACM profile configured and licensed capacity in each CTs of the RLT.
The maximum number is limited to 80."
::= { xfRLTDMIfEntry 8 }
xfTDMHopLength OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It represents the length of the radio hop expressed in Km.
This is used to calculate the propagation delay over the radio hop
that shall be compensated to guarantee TDM traffic error free.
Values:
- default value for delay compensation: -1
- admissible range of values in Km: 0-200
"
::= { xfRLTDMIfEntry 9 }
------------------------------------------------------------------------------
-- xfCGIfTable
------------------------------------------------------------------------------
xfCGIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfCGIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of ifTable reporting the main characteristics of CG i/f."
::= { xfRadioLinkRltObjects 9 }
xfCGIfEntry OBJECT-TYPE
SYNTAX XfCGIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfCGIfEntry."
INDEX { xfCGIfIndex }
::= { xfCGIfTable 1 }
XfCGIfEntry ::=
SEQUENCE
{
xfCGIfIndex Integer32,
xfCGIfMinSpeed Integer32,
xfCGIfMaxSpeed Gauge32,
xfCGIfRCNum INTEGER,
xfCGIfAlarms BITS,
xfCGIfHopViewStatus INTEGER
}
xfCGIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It is the ifIndex of CG interface."
::= { xfCGIfEntry 1 }
xfCGIfMinSpeed OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
The minimum speed (throughput) of this interface expressed in bit/s, including both Ethernet and TDM capacities.
Note: in case of bonding configurations, it represents the minimum of the min speeds
of all Carrier Terminations in the bonding group.
"
::= { xfCGIfEntry 2 }
xfCGIfMaxSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
The maximum speed (throughput) of this interface expressed in bit/s, including both Ethernet and TDM capacities.
Note: in case of bonding configurations, it represents the sum of the max speeds
of all Carrier Terminations in the bonding group.
"
::= { xfCGIfEntry 3 }
xfCGIfRCNum OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Carrier Termination members belonging to the CG group."
::= { xfCGIfEntry 4 }
xfCGIfAlarms OBJECT-TYPE
SYNTAX BITS
{
hccNe0(0),
hccNe1(1),
hccNe2(2),
rltId0(3),
rltId1(4),
rltId2(5),
txSwitchover0(6),
txSwitchover1(7),
txSwitchover2(8),
remoteTxSwitchOver0(9),
remoteTxSwitchOver1(10),
remoteTxSwitchOver2(11),
unableToProtect0(12),
unableToProtect1(13),
unableToProtect2(14),
rfInputThresholdProtection0(15),
rfInputThresholdProtection1(16),
rfInputThresholdProtection2(17),
unableToProtectEqp0(18),
unableToProtectEqp1(19),
unableToProtectEqp2(20)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows CG i/f related alarms."
::= { xfCGIfEntry 5 }
xfCGIfHopViewStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
down(2),
up(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the Hop View status.
Up: Far-End is reachable
Down: Far-End not reachable
The status is related to HCC-NE alarm.
"
::= { xfCGIfEntry 6 }
------------------------------------------------------------------------------
-- xfXPICPairTable
------------------------------------------------------------------------------
xfXPICPairTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfXPICPairEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to enable XPIC (Admid Status) and set the CT pair in XPIC."
::= { xfRadioLinkRltObjects 10 }
xfXPICPairEntry OBJECT-TYPE
SYNTAX XfXPICPairEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfXPICPairTable."
INDEX { entLogicalIndex, xfXpicPairIndex }
::= { xfXPICPairTable 1 }
XfXPICPairEntry ::=
SEQUENCE
{
xpicPairEntLogicalIIndex Integer32,
xfXPICPairAdminStatus INTEGER,
xfXPICPairNumber INTEGER,
xfXPICPairRecovery INTEGER,
xfXPICPairRestore INTEGER,
xfXPICCTmember1 DisplayString,
xfXPICCTmember2 DisplayString,
xfXPICAutoRestore INTEGER,
xfXpicPairIndex INTEGER
}
xpicPairEntLogicalIIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the entLogicalIndex of the Radio Link Terminal (RLT).
The logical entity identified by xpicPairEntLogicalIIndex is the same
entity as identified by the same value of entLogicalIndex.
"
::= { xfXPICPairEntry 1 }
xfXPICPairAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
enable(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative status of XPIC pair.
Default value: disable."
::= { xfXPICPairEntry 2 }
xfXPICPairNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It specifies the number used for identification of the XPIC pair."
::= { xfXPICPairEntry 3 }
xfXPICPairRecovery OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
enable(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It allows to enable/disable the recovery procedure when XPIC mode is enabled."
::= { xfXPICPairEntry 4 }
xfXPICPairRestore OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
xpicNoRestore(2),
xpicRestore(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Restore XPIC functionality after XPIC recovery has been triggered and resets
XPIC Auto Restore procedure"
::= { xfXPICPairEntry 5 }
xfXPICCTmember1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It specifies the first Carrier Termination (CT) member of the XPIC pair.
The member is identified by the CT distinguished name (R/S/P).
"
::= { xfXPICPairEntry 6 }
xfXPICCTmember2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It specifies the second Carrier Termination (CT) member of the XPIC pair.
The member is identified by the CT distinguished name (R/S/P).
"
::= { xfXPICPairEntry 7 }
xfXPICAutoRestore OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
enable(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It enable/disables the XPIC Auto Recovery procedure.
"
::= { xfXPICPairEntry 8 }
xfXpicPairIndex OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the table second index and is used to index the XPIC pair associated
to Radio Link Terminal (RLT) with entLogicalIndex equal to xpicPairEntLogicalIIndex.
It has been introduce to support configurations like 4+0 RLB EQP, 2+2 RLP EQP."
::= { xfXPICPairEntry 9 }
------------------------------------------------------------------------------
-- xfMIMOGroupTable
------------------------------------------------------------------------------
xfMIMOGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfMIMOGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to enable MIMO (Admid Status) and set the CTs in MIMO group."
::= { xfRadioLinkRltObjects 11 }
xfMIMOGroupEntry OBJECT-TYPE
SYNTAX XfMIMOGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfMIMOGroupTable."
INDEX { entLogicalIndex }
::= { xfMIMOGroupTable 1 }
XfMIMOGroupEntry ::=
SEQUENCE
{
mimoGroupEntLogicalIIndex Integer32,
xfMIMOGroupAdminStatus INTEGER,
xfMIMOGroupNumber INTEGER,
xfMIMOGroupRecovery INTEGER,
xfMIMOGroupRestore INTEGER,
xfMIMOCTmember1 DisplayString,
xfMIMOCTmember2 DisplayString,
xfMIMOCTmember3 DisplayString,
xfMIMOCTmember4 DisplayString
}
mimoGroupEntLogicalIIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the entLogicalIndex of the Radio Link Terminal (RLT).
The logical entity identified by mimoGroupEntLogicalIIndex is the same
entity as identified by the same value of entLogicalIndex.
"
::= { xfMIMOGroupEntry 1 }
xfMIMOGroupAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
enable(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative status of MIMO group.
Default value: disable.
"
::= { xfMIMOGroupEntry 2 }
xfMIMOGroupNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It specifies the Number used for identification of the MIMO group.
"
::= { xfMIMOGroupEntry 3 }
xfMIMOGroupRecovery OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
enable(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It allows to enable/disable the recovery procedure when MIMO mode is enabled."
::= { xfMIMOGroupEntry 4 }
xfMIMOGroupRestore OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
mimoNoRestore(2),
mimoRestore(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Restore MIMO functionality after MIMO recovery has been triggered."
::= { xfMIMOGroupEntry 5 }
xfMIMOCTmember1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It specifies the first Carrier Termination (CT) member of the MIMO group.
The member is identified by the CT distinguished name (R/S/P).
"
::= { xfMIMOGroupEntry 6 }
xfMIMOCTmember2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It specifies the second Carrier Termination (CT) member of the MIMO group.
The member is identified by the CT distinguished name (R/S/P).
"
::= { xfMIMOGroupEntry 7 }
xfMIMOCTmember3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It specifies the third Carrier Termination (CT) member of the MIMO group.
The member is identified by the CT distinguished name (R/S/P).
"
::= { xfMIMOGroupEntry 8 }
xfMIMOCTmember4 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It specifies the forth Carrier Termination (CT) member of the MIMO group.
The member is identified by the CT distinguished name (R/S/P).
"
::= { xfMIMOGroupEntry 9 }
------------------------------------------------------------------------------
-- xfRLWANIfTable
------------------------------------------------------------------------------
xfRLWANIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLWANIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to handle the RL-WAN i/f."
::= { xfRadioLinkRltObjects 12 }
xfRLWANIfEntry OBJECT-TYPE
SYNTAX XfRLWANIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfRLWANIfTable."
INDEX { xfRLWANIfIndex }
::= { xfRLWANIfTable 1 }
XfRLWANIfEntry ::=
SEQUENCE
{
xfRLWANIfIndex Integer32,
xfRLWANDistinguishedName DisplayString,
xfRLWANCompAdminStatus INTEGER,
xfRLWANCompConnStatus INTEGER,
xfRLWANMlhcMplsMode INTEGER,
xfRLWANMlhcOperStatus INTEGER,
xfRLWANPlcOperStatus INTEGER,
xfRLWANActualCapacity Gauge32,
xfRLWANLimitedCapacity Gauge32
}
xfRLWANIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It is the table index.
It contains the ifIndex value of the WAN interface.
"
::= { xfRLWANIfEntry 1 }
xfRLWANDistinguishedName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It is the name uniquely identifying the RL-WAN interface within the system, i.e. R/S/P."
::= { xfRLWANIfEntry 2 }
xfRLWANCompAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
down(2),
mlhcUp(3),
mlhcPlcUp(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It enables and disables MLHC and PLC on the RL-WAN interface.
down(2): both MLHC and PLC are disabled.
mlhcUp(3): only MLHC is enabled.
mlhcPlcUp(4): both MLHC and PLC are enabled.
Default:down(2).
Compression can be enabled on only one of the two RL-WAN interfaces belonging to the same MMU.
Any attempt to enable compression on both RL-WAN interfaces belonging to the same MMU is refused.
"
::= { xfRLWANIfEntry 3 }
xfRLWANCompConnStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
disconnected(2),
connected(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It specifies if the compression building block is physically connected to the RL-WAN interface.
Physical connection of the compression building block to the RL-WAN interface is pre-requisite for enabling compression.
When xfRLWANCompAdminStatus is set either to mlhcUp or mlhcPlcUp, the compression building block
is physically connected to RL-WAN interfaces and xfRLWANCompConnStatus becomes connected.
When xfRLWANCompAdminStatus is set either to mlhcUp or mlhcPlcUp on the other RL-WAN interface,
the compression building block is physically connected to the other RL-WAN interfaces
and xfRLWANCompConnStatus becomes disconnected.
"
::= { xfRLWANIfEntry 4 }
xfRLWANMlhcMplsMode OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
mplsOnly(2),
controlWord(3),
l2(4),
l3(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It specifies the wanted mpls mode.
mplsOnly(2): Ethernet customer bridge, provider bridge and QinQ headers, including MPLS labels (up to 3) are compressed.
controlWord(3): L2 VPN with Pseudo-Wire Control Word headers are compressed.
l2(4): L2 VPN without Pseudo-Wire Control Word headers are compressed.
l3(5): L3 VPN headers are compressed.
Default: mplsOnly(2).
This can be configured only if compression administrative status is down.
"
::= { xfRLWANIfEntry 5 }
xfRLWANMlhcOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
down(2),
up(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multi-Layer Header Compression operative status.
"
::= { xfRLWANIfEntry 6 }
xfRLWANPlcOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
down(2),
up(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Payload Compression operative status.
"
::= { xfRLWANIfEntry 7 }
xfRLWANActualCapacity OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual Capacity (speed) of RL WAN interface, in bps.
"
::= { xfRLWANIfEntry 8 }
xfRLWANLimitedCapacity OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Capacity (speed) limited by license of RL WAN interface, in bps.
"
::= { xfRLWANIfEntry 9 }
------------------------------------------------------------------------------
-- xfRLTHierarchyModuleTable
------------------------------------------------------------------------------
xfRLTHierarchyModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLTHierarchyModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to handle Module (MMU - RAU) hierarchy for the specific RLT."
::= { xfRadioLinkRltObjects 13 }
xfRLTHierarchyModuleEntry OBJECT-TYPE
SYNTAX XfRLTHierarchyModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfRLTHierarchyModuleTable."
INDEX { xfRLTMHIndex, xfRLTModuleIndex }
::= { xfRLTHierarchyModuleTable 1 }
XfRLTHierarchyModuleEntry ::=
SEQUENCE
{
xfRLTMHIndex Integer32,
xfRLTModuleIndex Integer32,
xfRLTEntPhysicalIndex Integer32,
xfRLTPhysicalCointainedIn Integer32,
xfRLTPhysicalParentRelPos Integer32,
xfRLTEntityPhysicalDescr DisplayString,
xfRLTModuleSlotPosition Integer32,
xfRLTNEDistinguishedName DisplayString,
xfRLTFEDistinguishedName DisplayString,
xfRLTInterfaceIndex Integer32,
xfRLTHighestSeverityAlarm INTEGER
}
xfRLTMHIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It is the table index.
It contains the entPhisycalIndex of the WAN port associated to the RLT.
"
::= { xfRLTHierarchyModuleEntry 1 }
xfRLTModuleIndex OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It is the table index.
It is a sequential number referred to the module (entity), either MMU or RAU, constituting the RLT.
"
::= { xfRLTHierarchyModuleEntry 2 }
xfRLTEntPhysicalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This MO represents the value of entPhysicalIndex of the module, either MMU or RAU,
constituting the RLT.
"
::= { xfRLTHierarchyModuleEntry 3 }
xfRLTPhysicalCointainedIn OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This MO represents the value of entPhysicalIndex for the physical entity which
'contains' this physical entity, which is either MMU or RAU (constituting the RLT).
"
::= { xfRLTHierarchyModuleEntry 4 }
xfRLTPhysicalParentRelPos OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This MO represents the indication of the relative position of this 'child'
component among all its 'sibling' components.
"
::= { xfRLTHierarchyModuleEntry 5 }
xfRLTEntityPhysicalDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This MO represents a textual description of physical entity (module),
either MMU or RAU, constituting the RLT.
"
::= { xfRLTHierarchyModuleEntry 6 }
xfRLTModuleSlotPosition OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This MO represents the slot position of the physical entity (module),
either MMU or RAU, constituting the RLT.
"
::= { xfRLTHierarchyModuleEntry 7 }
xfRLTFEDistinguishedName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This MO represents the distinguished name of the Near-End logical entity,
either RLT or CT.
"
::= { xfRLTHierarchyModuleEntry 8 }
xfRLTNEDistinguishedName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This MO represents the distinguished name of the Far-End logical entity,
either RLT or CT.
"
::= { xfRLTHierarchyModuleEntry 9 }
xfRLTInterfaceIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This MO represents the value of ifIndex of the interface, either CG IF (Bonding/RLP) or RAU IF,
constituting the RLT.
"
::= { xfRLTHierarchyModuleEntry 10 }
xfRLTHighestSeverityAlarm OBJECT-TYPE
SYNTAX INTEGER
{
critical(0),
major(1),
minor(2),
warning(3),
clear(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
This MO reports the highest severity of the alarms active in the physical module, MMU or RAU, it refers to.
Value list:
- critical(0): highest severity is Critical;
- major(1): highest severity is Major;
- minor(2): highest severity is Minor;
- warning(3): highest severity is Warning;
- clear(4): no alarm.
"
::= { xfRLTHierarchyModuleEntry 11 }
------------------------------------------------------------------------------
-- xfRLTProtectionTable
------------------------------------------------------------------------------
xfRLTProtectionTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLTProtectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to handle RL Protection for the RLT whose mode is set 1+1RLP."
::= { xfRadioLinkRltObjects 14 }
xfRLTProtectionEntry OBJECT-TYPE
SYNTAX XfRLTProtectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfRLTProtectionTable."
INDEX { xfRLTProtIndex}
::= { xfRLTProtectionTable 1 }
XfRLTProtectionEntry ::=
SEQUENCE
{
xfRLTProtIndex Integer32,
xfRLTProtectionSwitchMode INTEGER,
xfRLTProtectionStatus INTEGER,
xfRLTRevertivePreferredTX DisplayString,
xfRLTProtectionWaitToRestoreTime INTEGER,
xfRLTFadeNotificationTimer INTEGER,
xfRLTManualSwitchCommand INTEGER,
xfRLTTxSwitchOverConfiguration INTEGER,
xfRLTTxSwitchOverAlarmReset INTEGER,
xfRLTNumOfRLPSwitch Integer32,
xfRLTEnhancedACMProtectionMode INTEGER,
xfRLTEnhancedACMProtectionOperStatus INTEGER
}
xfRLTProtIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It is the table index.
It contains the entity logical index of the RLT configured in 1+1RLP.
"
::= { xfRLTProtectionEntry 1 }
xfRLTProtectionSwitchMode OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
auto(2),
manual(3),
autoRevertive(4),
txSwitchDisable(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mode in which the switching mechanism is configured.
Auto: System automatically switches from the degraded to the other transmitter (Tx).
Manual: Automatic switching is disabled and operator can select Tx manually.
Auto & Revertive: makes it possible to manually set the preferred Tx.
TX switch disable: Selective Space Diverity, SSD.
RLP TX switch is disabled.
The two received signals, from different paths, are combined.
Default: AUTO (for RLT mode RLP) & NA (default for RLT mode RLB).
"
::= { xfRLTProtectionEntry 2 }
xfRLTProtectionStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
unprotected(2),
protected(3),
unableToProtect(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the protection, when configured in a protected mode.
Values:
- unprotected;
- protected
- unableToProtect
Note:
Applicable only when RLT-mode is RL protection.
"
::= { xfRLTProtectionEntry 3 }
xfRLTRevertivePreferredTX OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It specifies the preferred TX Radio Carrier Termination (CT) in revertive protection mode.
The member is identified by the CT distinguished name (R/S/P).
"
::= { xfRLTProtectionEntry 4 }
xfRLTProtectionWaitToRestoreTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time, in # of seconds, to wait before switching back to the preferred Tx in Auto & Revertive mode.
Default: 0.
"
::= { xfRLTProtectionEntry 5 }
xfRLTFadeNotificationTimer OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Notifications for alarms caused by fading, with a duration less than the specified time (0 - 1000 seconds) are not sent.
Only applicable for protected configurations.
Default: 200.
"
::= { xfRLTProtectionEntry 6 }
xfRLTManualSwitchCommand OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
txManualSwitch(2),
txManualNoSwitch(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to request a TX switch-over.
Applicable for protected configurations and when protectionSwitchMode is set to Manual.
Not Applicable for RLT mode RLB
Value:
- txManualSwitch
- txManualNoSwitch.
"
::= { xfRLTProtectionEntry 7 }
xfRLTTxSwitchOverConfiguration OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
notSupported(2),
enable(3),
disable(4),
enableLocal(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable the function to switch TX on a request from far-end, including also the TX switchover alarm notifications , both local and remote. Only applicable in RLT mode RLP.
Values:
- notSupported: (default for RLT in RLB mode)
- enable: TX switchover triggered by local and remote faults
- disable: TX switchover disabled(default for RLT in RLP mode) - DEPRECATED
- enableLocal: TX switchover triggered by local faults only (default for RLT in RLP mode)
"
::= { xfRLTProtectionEntry 8 }
xfRLTTxSwitchOverAlarmReset OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
txSwitchOverAlarmNoReset(2),
txSwitchOverAlarmReset(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to manual reset the TX switch-over alarm and Remote TX switchover alarm (consequently to TX switch ordered from far-end).
Note: the alarm is raised when TX Switch far-end function is enabled (xfRLTTxSwitchOverConfiguration).
Value:
- txSwitchOverAlarmNoReset
- txSwitchOverAlarmReset.
"
::= { xfRLTProtectionEntry 9 }
xfRLTNumOfRLPSwitch OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the number of RLP Radio TX switch.
"
::= { xfRLTProtectionEntry 10 }
xfRLTEnhancedACMProtectionMode OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
activeTransmitter(2),
maximumCapacity(3),
maximumProtection(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It configures the enhanced ACM protection mode. The enhanced ACM protection uses RX indicators from both the working and the protection links
to select an ACM profile to optimize capacity (throughput) and/or protection (robustness).
Values:
- Active Transmitter : ACM engine determines the ACM profile according to the working Rx ACM indications only;
- Maximum Capacity (default): Working Rx ACM engine is aware of the ACM profile requests from the
protection Rx ACM engine, and determines the highest ACM profile between
the working and the protection links;
- Maximum Protection : Working Rx ACM engine is aware of the protection Rx ACM engine's ACM
profile requests, and determines the lowest ACM profile between the working
and the protection links.
"
::= { xfRLTProtectionEntry 11 }
xfRLTEnhancedACMProtectionOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
notApplicable(2),
enhAcmProtActive(3),
enhAcmProtNotActive(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the enhanched ACM protection engine, when ACM engine is configured either in maximum-troughtput or maximum-protection mode.
Values:
- notApplicable : when enhanced ACM protection mode is basic;
- enhAcmProtActive : when the enhanced ACM engine is working and the highest ACM profile is selected
between the working and the protection links;
- enhAcmProtNotActive: when the enhanced ACM engine is not working.
"
::= { xfRLTProtectionEntry 12 }
------------------------------------------------------------------------------
-- xfRLTEncryptionTable
------------------------------------------------------------------------------
xfRLTEncryptionTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLTEncryptionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to handle Radio Link Encryption."
::= { xfRadioLinkRltObjects 15 }
xfRLTEncryptionEntry OBJECT-TYPE
SYNTAX XfRLTEncryptionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfRLTEncryptionTable."
INDEX { xfRLTEncryptionIndex}
::= { xfRLTEncryptionTable 1 }
XfRLTEncryptionEntry ::=
SEQUENCE
{
xfRLTEncryptionIndex Integer32,
xfRLTEncryptionAdminStatus INTEGER,
xfRLTEncryptionOperStatus INTEGER,
xfRLTEncryptionMasterKey DisplayString
}
xfRLTEncryptionIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It represents the xfRLTEncryptionTable index and is the RLT entity logical index."
::= { xfRLTEncryptionEntry 1 }
xfRLTEncryptionAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
enable(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MO allows to enable/disable the Encryption of both control and traffic plain over the Radio Link hop.
Values:
- enable;
- disable.
Default: DISABLE.
"
::= { xfRLTEncryptionEntry 2 }
xfRLTEncryptionOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
up(2),
down(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This MO represents the Operative Status of the Encryption function over the Radio Link hop
and refers to receiving direction. Therefore, it indicates if the receiving side is able or
not able to correctly/successfully decipher the ciphered data stream transmitted from remote side..
The ecryption status can assume the values:
- up: control and traffic plain are correctly deciphered;
- down: control and traffic plain are not deciphered correctly/successfully, due to e.g. authentication failure, disturbance over the radio-hop.
"
::= { xfRLTEncryptionEntry 3 }
xfRLTEncryptionMasterKey OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MO allows to define the Master Key used to initiate the Encryption operation.
Master Key is hidden.
"
::= { xfRLTEncryptionEntry 4 }
--
------------------------------------------------------------------------------
-- xfRadioLinkRltPmObjects
------------------------------------------------------------------------------
-- The xfRadioLinkRltPmObjects MOs
------------------------------------------------------------------------------
-- xfRLPMContinuousCounterTable
------------------------------------------------------------------------------
xfRLPMContinuousCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLPMContinuousCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for RLT performance data."
::= { xfRadioLinkRltPmObjects 1 }
xfRLPMContinuousCounterEntry OBJECT-TYPE
SYNTAX XfRLPMContinuousCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfRLPMContinuousCounterTable."
INDEX { ifIndex }
::= { xfRLPMContinuousCounterTable 1 }
XfRLPMContinuousCounterEntry ::=
SEQUENCE
{
xfPMTimeElapsed PerfIntervalCount,
xfPMCurrentES PerfCurrentCount,
xfPMCurrentSES PerfCurrentCount,
xfPMCurrentBBE HCPerfCurrentCount,
xfPMCurrentUAS PerfCurrentCount,
xfPMCurrentBB HCPerfCurrentCount,
xfPMPerfReset INTEGER,
xfPMCurrentESR PerfCurrentCount,
xfPMCurrentSESR PerfCurrentCount,
xfPMCurrentBBER HCPerfCurrentCount
}
xfPMTimeElapsed OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
The number of seconds that have elapsed since the beginning
of the current error-measurement period.
If the current interval exceeds the maximum
value, the agent will return the maximum value.
Reset by xfPMPerfReset.
"
::= { xfRLPMContinuousCounterEntry 1 }
xfPMCurrentES OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the errored seconds.
Reset by xfPMPerfReset."
::= { xfRLPMContinuousCounterEntry 2 }
xfPMCurrentSES OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the severely errored seconds.
Reset by xfPMPerfReset."
::= { xfRLPMContinuousCounterEntry 3 }
xfPMCurrentBBE OBJECT-TYPE
SYNTAX HCPerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the background block errors.
Reset by xfPMPerfReset."
::= { xfRLPMContinuousCounterEntry 4 }
xfPMCurrentUAS OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the unavailable seconds (or unavailable time).
Reset by xfPMPerfReset."
::= { xfRLPMContinuousCounterEntry 5 }
xfPMCurrentBB OBJECT-TYPE
SYNTAX HCPerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the background blocks.
Reset by xfPMPerfReset."
::= { xfRLPMContinuousCounterEntry 6 }
xfPMPerfReset OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
noReset(2),
reset(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
This object is used to reset the performance counters:
- Elapsed Time, ES, SES, BBE, BB
- PM ACM
- ETSI - EN 301 129 (TLTS, RLTS, ...) current/interval 15m/24h
- Max and Min XPI/MSE current/interval 15m/24h
It can be also set when the RAU is not present.
Near end access: read-write.
"
::= { xfRLPMContinuousCounterEntry 7 }
xfPMCurrentESR OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ratio of ES to total seconds in available time during a
fixed measurement interval.
Reset by xfPMPerfReset."
::= { xfRLPMContinuousCounterEntry 8 }
xfPMCurrentSESR OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ratio of SES to total seconds in available time
during a fixed measurement interval.
Reset by xfPMPerfReset."
::= { xfRLPMContinuousCounterEntry 9 }
xfPMCurrentBBER OBJECT-TYPE
SYNTAX HCPerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ratio of Background Block Errors (BBE) to total blocks in
available time during a fixed measurement interval.
Reset by xfPMPerfReset."
::= { xfRLPMContinuousCounterEntry 10 }
------------------------------------------------------------------------------
-- xfRLPMACMConfigTable
------------------------------------------------------------------------------
xfRLPMACMConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLPMACMConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Alarm threshold values for RL PM."
::= { xfRadioLinkRltPmObjects 2 }
xfRLPMACMConfigEntry OBJECT-TYPE
SYNTAX XfRLPMACMConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the xfRLPMACMConfigTable"
INDEX { ifIndex }
::= { xfRLPMACMConfigTable 1 }
XfRLPMACMConfigEntry ::=
SEQUENCE
{
xfPMACMSetThreshold15m Integer32,
xfPMACMSetThreshold24h Integer32,
xfPMACMResetThreshold15m Integer32,
xfPMACMStatus BITS,
xfPMACMValidData BITS
}
xfPMACMSetThreshold15m OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 15 minute set threshold for minimum modulation.
Near end access: read-write.
Far end access: no access.
Default value is 180.
"
::= { xfRLPMACMConfigEntry 1 }
xfPMACMSetThreshold24h OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 24 hour set threshold for minimum modulation.
Near end access: read-write.
Far end access: no access.
Default value is 1500.
"
::= { xfRLPMACMConfigEntry 2 }
xfPMACMResetThreshold15m OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 15 minute reset threshold for minimum modulation.
Near end access: read-write.
Far end access: no access.
Default value is 20.
"
::= { xfRLPMACMConfigEntry 3 }
xfPMACMStatus OBJECT-TYPE
SYNTAX BITS
{
acm15m0(0),
acm15m1(1),
acm15m2(2),
acm24h0(3),
acm24h1(4),
acm24h2(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
It reports threshold crossing alarm status:
- acm15m: ACM 15 min threshold crossing: ACM has been in the lowest configured profile
for a number of seconds exceeding the configured 15 min threshold.
- acm24h: ACM 24 hour threshold crossing: ACM has been in the lowest configured profile
for a number of seconds exceeding the configured 24 hour threshold.
"
::= { xfRLPMACMConfigEntry 4 }
xfPMACMValidData OBJECT-TYPE
SYNTAX BITS
{
valid15m4QAMStrong(0),
valid15m4QAMStd(1),
valid15m4QAMLight(2),
valid15m16QAMStrong(3),
valid15m16QAMStd(4),
valid15m16QAMLight(5),
valid15m32QAMStrong(6),
valid15m32QAMStd(7),
valid15m32QAMLight(8),
valid15m64QAMStrong(9),
valid15m64QAMStd(10),
valid15m64QAMLight(11),
valid15m128QAMStrong(12),
valid15m128QAMStd(13),
valid15m128QAMLight(14),
valid15m256QAMStrong(15),
valid15m256QAMStd(16),
valid15m256QAMLight(17),
valid15m512QAMStrong(18),
valid15m512QAMStd(19),
valid15m512QAMLight(20),
valid15m1024QAMStrong(21),
valid15m1024QAMStd(22),
valid15m1024QAMLight(23),
valid15m2048QAMStrong(24),
valid15m2048QAMStd(25),
valid15m2048QAMLight(26),
valid15m4096QAMStrong(27),
valid15m4096QAMStd(28),
valid15m4096QAMLight(29),
valid15m8192QAMStrong(30),
valid15m8192QAMStd(31),
valid15m8192QAMLight(32),
valid15m16384QAMStrong(33),
valid15m16384QAMStd(34),
valid15m16384QAMLight(35)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It reports which ACM's PM data are valid."
::= { xfRLPMACMConfigEntry 5 }
------------------------------------------------------------------------------
-- xfRLPMACMCurrent24hTable
------------------------------------------------------------------------------
xfRLPMACMCurrent24hTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLPMACMCurrent24hEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ACM-based counters for current 24h table."
::= { xfRadioLinkRltPmObjects 3 }
xfRLPMACMCurrent24hEntry OBJECT-TYPE
SYNTAX XfRLPMACMCurrent24hEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the xfRLPMACMCurrent24hTable."
INDEX { ifIndex }
::= { xfRLPMACMCurrent24hTable 1 }
XfRLPMACMCurrent24hEntry ::=
SEQUENCE
{
xfPMACMCurrent24h4QAMStrong PerfCurrentCount,
xfPMACMCurrent24h4QAMStd PerfCurrentCount,
xfPMACMCurrent24h4QAMLight PerfCurrentCount,
xfPMACMCurrent24h16QAMStrong PerfCurrentCount,
xfPMACMCurrent24h16QAMStd PerfCurrentCount,
xfPMACMCurrent24h16QAMLight PerfCurrentCount,
xfPMACMCurrent24h32QAMStrong PerfCurrentCount,
xfPMACMCurrent24h32QAMStd PerfCurrentCount,
xfPMACMCurrent24h32QAMLight PerfCurrentCount,
xfPMACMCurrent24h64QAMStrong PerfCurrentCount,
xfPMACMCurrent24h64QAMStd PerfCurrentCount,
xfPMACMCurrent24h64QAMLight PerfCurrentCount,
xfPMACMCurrent24h128QAMStrong PerfCurrentCount,
xfPMACMCurrent24h128QAMStd PerfCurrentCount,
xfPMACMCurrent24h128QAMLight PerfCurrentCount,
xfPMACMCurrent24h256QAMStrong PerfCurrentCount,
xfPMACMCurrent24h256QAMStd PerfCurrentCount,
xfPMACMCurrent24h256QAMLight PerfCurrentCount,
xfPMACMCurrent24h512QAMStrong PerfCurrentCount,
xfPMACMCurrent24h512QAMStd PerfCurrentCount,
xfPMACMCurrent24h512QAMLight PerfCurrentCount,
xfPMACMCurrent24h1024QAMStrong PerfCurrentCount,
xfPMACMCurrent24h1024QAMStd PerfCurrentCount,
xfPMACMCurrent24h1024QAMLight PerfCurrentCount,
xfPMACMCurrent24h2048QAMStrong PerfCurrentCount,
xfPMACMCurrent24h2048QAMStd PerfCurrentCount,
xfPMACMCurrent24h2048QAMLight PerfCurrentCount,
xfPMACMCurrent24h4096QAMStrong PerfCurrentCount,
xfPMACMCurrent24h4096QAMStd PerfCurrentCount,
xfPMACMCurrent24h4096QAMLight PerfCurrentCount,
xfPMACMCurrent24h8192QAMStrong PerfCurrentCount,
xfPMACMCurrent24h8192QAMStd PerfCurrentCount,
xfPMACMCurrent24h8192QAMLight PerfCurrentCount,
xfPMACMCurrent24h16384QAMStrong PerfCurrentCount,
xfPMACMCurrent24h16384QAMStd PerfCurrentCount,
xfPMACMCurrent24h16384QAMLight PerfCurrentCount
}
xfPMACMCurrent24h4QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 1 }
xfPMACMCurrent24h4QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 2 }
xfPMACMCurrent24h4QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 3 }
xfPMACMCurrent24h16QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 4 }
xfPMACMCurrent24h16QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 5 }
xfPMACMCurrent24h16QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 6 }
xfPMACMCurrent24h32QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 7 }
xfPMACMCurrent24h32QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 8 }
xfPMACMCurrent24h32QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 9 }
xfPMACMCurrent24h64QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 10 }
xfPMACMCurrent24h64QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 11 }
xfPMACMCurrent24h64QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 12 }
xfPMACMCurrent24h128QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 13 }
xfPMACMCurrent24h128QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 14 }
xfPMACMCurrent24h128QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 15 }
xfPMACMCurrent24h256QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 16 }
xfPMACMCurrent24h256QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 17 }
xfPMACMCurrent24h256QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 18 }
xfPMACMCurrent24h512QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 19 }
xfPMACMCurrent24h512QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 20 }
xfPMACMCurrent24h512QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 21 }
xfPMACMCurrent24h1024QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 22 }
xfPMACMCurrent24h1024QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 23 }
xfPMACMCurrent24h1024QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 24 }
xfPMACMCurrent24h2048QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 25 }
xfPMACMCurrent24h2048QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 26 }
xfPMACMCurrent24h2048QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 27 }
xfPMACMCurrent24h4096QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 28 }
xfPMACMCurrent24h4096QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 29 }
xfPMACMCurrent24h4096QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 30 }
xfPMACMCurrent24h8192QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 31 }
xfPMACMCurrent24h8192QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 32 }
xfPMACMCurrent24h8192QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 33 }
xfPMACMCurrent24h16384QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 34 }
xfPMACMCurrent24h16384QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 35 }
xfPMACMCurrent24h16384QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid time since reset."
::= { xfRLPMACMCurrent24hEntry 36 }
------------------------------------------------------------------------------
-- xfRLPMACMInterval24hTable
------------------------------------------------------------------------------
xfRLPMACMInterval24hTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLPMACMInterval24hEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ACM-based counters for interval 24h table."
::= { xfRadioLinkRltPmObjects 4 }
xfRLPMACMInterval24hEntry OBJECT-TYPE
SYNTAX XfRLPMACMInterval24hEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the xfRLPMACMInterval24hTable."
INDEX { ifIndex }
::= { xfRLPMACMInterval24hTable 1 }
XfRLPMACMInterval24hEntry ::=
SEQUENCE
{
xfPMACMInterval24h4QAMStrong PerfIntervalCount,
xfPMACMInterval24h4QAMStd PerfIntervalCount,
xfPMACMInterval24h4QAMLight PerfIntervalCount,
xfPMACMInterval24h16QAMStrong PerfIntervalCount,
xfPMACMInterval24h16QAMStd PerfIntervalCount,
xfPMACMInterval24h16QAMLight PerfIntervalCount,
xfPMACMInterval24h32QAMStrong PerfIntervalCount,
xfPMACMInterval24h32QAMStd PerfIntervalCount,
xfPMACMInterval24h32QAMLight PerfIntervalCount,
xfPMACMInterval24h64QAMStrong PerfIntervalCount,
xfPMACMInterval24h64QAMStd PerfIntervalCount,
xfPMACMInterval24h64QAMLight PerfIntervalCount,
xfPMACMInterval24h128QAMStrong PerfIntervalCount,
xfPMACMInterval24h128QAMStd PerfIntervalCount,
xfPMACMInterval24h128QAMLight PerfIntervalCount,
xfPMACMInterval24h256QAMStrong PerfIntervalCount,
xfPMACMInterval24h256QAMStd PerfIntervalCount,
xfPMACMInterval24h256QAMLight PerfIntervalCount,
xfPMACMInterval24h512QAMStrong PerfIntervalCount,
xfPMACMInterval24h512QAMStd PerfIntervalCount,
xfPMACMInterval24h512QAMLight PerfIntervalCount,
xfPMACMInterval24h1024QAMStrong PerfIntervalCount,
xfPMACMInterval24h1024QAMStd PerfIntervalCount,
xfPMACMInterval24h1024QAMLight PerfIntervalCount,
xfPMACMInterval24h2048QAMStrong PerfIntervalCount,
xfPMACMInterval24h2048QAMStd PerfIntervalCount,
xfPMACMInterval24h2048QAMLight PerfIntervalCount,
xfPMACMInterval24h4096QAMStrong PerfIntervalCount,
xfPMACMInterval24h4096QAMStd PerfIntervalCount,
xfPMACMInterval24h4096QAMLight PerfIntervalCount,
xfPMACMInterval24hValidData TruthValue,
xfPMACMInterval24h8192QAMStrong PerfIntervalCount,
xfPMACMInterval24h8192QAMStd PerfIntervalCount,
xfPMACMInterval24h8192QAMLight PerfIntervalCount,
xfPMACMInterval24h16384QAMStrong PerfIntervalCount,
xfPMACMInterval24h16384QAMStd PerfIntervalCount,
xfPMACMInterval24h16384QAMLight PerfIntervalCount
}
xfPMACMInterval24h4QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 1 }
xfPMACMInterval24h4QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 2 }
xfPMACMInterval24h4QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 3 }
xfPMACMInterval24h16QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 4 }
xfPMACMInterval24h16QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 5 }
xfPMACMInterval24h16QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 6 }
xfPMACMInterval24h32QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 7 }
xfPMACMInterval24h32QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 8 }
xfPMACMInterval24h32QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 9 }
xfPMACMInterval24h64QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 10 }
xfPMACMInterval24h64QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 11 }
xfPMACMInterval24h64QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 12 }
xfPMACMInterval24h128QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 13 }
xfPMACMInterval24h128QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 14 }
xfPMACMInterval24h128QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 15 }
xfPMACMInterval24h256QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 16 }
xfPMACMInterval24h256QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 17 }
xfPMACMInterval24h256QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 18 }
xfPMACMInterval24h512QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 19 }
xfPMACMInterval24h512QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 20 }
xfPMACMInterval24h512QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 21 }
xfPMACMInterval24h1024QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 22 }
xfPMACMInterval24h1024QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 23 }
xfPMACMInterval24h1024QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 24 }
xfPMACMInterval24h2048QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 25 }
xfPMACMInterval24h2048QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 26 }
xfPMACMInterval24h2048QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 27 }
xfPMACMInterval24h4096QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 28 }
xfPMACMInterval24h4096QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 29 }
xfPMACMInterval24h4096QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 30 }
xfPMACMInterval24hValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates whether the data for this interval is valid."
::= { xfRLPMACMInterval24hEntry 31 }
xfPMACMInterval24h8192QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 32 }
xfPMACMInterval24h8192QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 33 }
xfPMACMInterval24h8192QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 34 }
xfPMACMInterval24h16384QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 35 }
xfPMACMInterval24h16384QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 36 }
xfPMACMInterval24h16384QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval24hEntry 37 }
------------------------------------------------------------------------------
-- xfRLPMACMCurrent15mTable
------------------------------------------------------------------------------
xfRLPMACMCurrent15mTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLPMACMCurrent15mEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ACM-based counters for current 15m table."
::= { xfRadioLinkRltPmObjects 5 }
xfRLPMACMCurrent15mEntry OBJECT-TYPE
SYNTAX XfRLPMACMCurrent15mEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the table."
INDEX { ifIndex }
::= { xfRLPMACMCurrent15mTable 1 }
XfRLPMACMCurrent15mEntry ::=
SEQUENCE
{
xfPMACMCurrent15m4QAMStrong PerfCurrentCount,
xfPMACMCurrent15m4QAMStd PerfCurrentCount,
xfPMACMCurrent15m4QAMLight PerfCurrentCount,
xfPMACMCurrent15m16QAMStrong PerfCurrentCount,
xfPMACMCurrent15m16QAMStd PerfCurrentCount,
xfPMACMCurrent15m16QAMLight PerfCurrentCount,
xfPMACMCurrent15m32QAMStrong PerfCurrentCount,
xfPMACMCurrent15m32QAMStd PerfCurrentCount,
xfPMACMCurrent15m32QAMLight PerfCurrentCount,
xfPMACMCurrent15m64QAMStrong PerfCurrentCount,
xfPMACMCurrent15m64QAMStd PerfCurrentCount,
xfPMACMCurrent15m64QAMLight PerfCurrentCount,
xfPMACMCurrent15m128QAMStrong PerfCurrentCount,
xfPMACMCurrent15m128QAMStd PerfCurrentCount,
xfPMACMCurrent15m128QAMLight PerfCurrentCount,
xfPMACMCurrent15m256QAMStrong PerfCurrentCount,
xfPMACMCurrent15m256QAMStd PerfCurrentCount,
xfPMACMCurrent15m256QAMLight PerfCurrentCount,
xfPMACMCurrent15m512QAMStrong PerfCurrentCount,
xfPMACMCurrent15m512QAMStd PerfCurrentCount,
xfPMACMCurrent15m512QAMLight PerfCurrentCount,
xfPMACMCurrent15m1024QAMStrong PerfCurrentCount,
xfPMACMCurrent15m1024QAMStd PerfCurrentCount,
xfPMACMCurrent15m1024QAMLight PerfCurrentCount,
xfPMACMCurrent15m2048QAMStrong PerfCurrentCount,
xfPMACMCurrent15m2048QAMStd PerfCurrentCount,
xfPMACMCurrent15m2048QAMLight PerfCurrentCount,
xfPMACMCurrent15m4096QAMStrong PerfCurrentCount,
xfPMACMCurrent15m4096QAMStd PerfCurrentCount,
xfPMACMCurrent15m4096QAMLight PerfCurrentCount,
xfPMACMCurrent15m8192QAMStrong PerfCurrentCount,
xfPMACMCurrent15m8192QAMStd PerfCurrentCount,
xfPMACMCurrent15m8192QAMLight PerfCurrentCount,
xfPMACMCurrent15m16384QAMStrong PerfCurrentCount,
xfPMACMCurrent15m16384QAMStd PerfCurrentCount,
xfPMACMCurrent15m16384QAMLight PerfCurrentCount
}
xfPMACMCurrent15m4QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 1 }
xfPMACMCurrent15m4QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 2 }
xfPMACMCurrent15m4QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 3 }
xfPMACMCurrent15m16QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 4 }
xfPMACMCurrent15m16QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 5 }
xfPMACMCurrent15m16QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 6 }
xfPMACMCurrent15m32QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 7 }
xfPMACMCurrent15m32QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 8 }
xfPMACMCurrent15m32QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 9 }
xfPMACMCurrent15m64QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 10 }
xfPMACMCurrent15m64QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 11 }
xfPMACMCurrent15m64QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 12 }
xfPMACMCurrent15m128QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 13 }
xfPMACMCurrent15m128QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 14 }
xfPMACMCurrent15m128QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 15 }
xfPMACMCurrent15m256QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 16 }
xfPMACMCurrent15m256QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 17 }
xfPMACMCurrent15m256QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 18 }
xfPMACMCurrent15m512QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 19 }
xfPMACMCurrent15m512QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 20 }
xfPMACMCurrent15m512QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 21 }
xfPMACMCurrent15m1024QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 22 }
xfPMACMCurrent15m1024QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 23 }
xfPMACMCurrent15m1024QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 24 }
xfPMACMCurrent15m2048QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 25 }
xfPMACMCurrent15m2048QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 26 }
xfPMACMCurrent15m2048QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 27 }
xfPMACMCurrent15m4096QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 28 }
xfPMACMCurrent15m4096QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 29 }
xfPMACMCurrent15m4096QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 30 }
xfPMACMCurrent15m8192QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 31 }
xfPMACMCurrent15m8192QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 32 }
xfPMACMCurrent15m8192QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 33 }
xfPMACMCurrent15m16384QAMStrong OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 34 }
xfPMACMCurrent15m16384QAMStd OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 35 }
xfPMACMCurrent15m16384QAMLight OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Valid interval time since reset."
::= { xfRLPMACMCurrent15mEntry 36 }
------------------------------------------------------------------------------
-- xfRLPMACMInterval15mTable
------------------------------------------------------------------------------
xfRLPMACMInterval15mTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLPMACMInterval15mEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ACM-based counters for interval 15m table."
::= { xfRadioLinkRltPmObjects 6 }
xfRLPMACMInterval15mEntry OBJECT-TYPE
SYNTAX XfRLPMACMInterval15mEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the table."
INDEX { ifIndex, xfPMACMInterval15mIntervalNumber }
::= { xfRLPMACMInterval15mTable 1 }
XfRLPMACMInterval15mEntry ::=
SEQUENCE
{
xfPMACMInterval15mIntervalNumber Integer32,
xfPMACMInterval15m4QAMStrong PerfIntervalCount,
xfPMACMInterval15m4QAMStd PerfIntervalCount,
xfPMACMInterval15m4QAMLight PerfIntervalCount,
xfPMACMInterval15m16QAMStrong PerfIntervalCount,
xfPMACMInterval15m16QAMStd PerfIntervalCount,
xfPMACMInterval15m16QAMLight PerfIntervalCount,
xfPMACMInterval15m32QAMStrong PerfIntervalCount,
xfPMACMInterval15m32QAMStd PerfIntervalCount,
xfPMACMInterval15m32QAMLight PerfIntervalCount,
xfPMACMInterval15m64QAMStrong PerfIntervalCount,
xfPMACMInterval15m64QAMStd PerfIntervalCount,
xfPMACMInterval15m64QAMLight PerfIntervalCount,
xfPMACMInterval15m128QAMStrong PerfIntervalCount,
xfPMACMInterval15m128QAMStd PerfIntervalCount,
xfPMACMInterval15m128QAMLight PerfIntervalCount,
xfPMACMInterval15m256QAMStrong PerfIntervalCount,
xfPMACMInterval15m256QAMStd PerfIntervalCount,
xfPMACMInterval15m256QAMLight PerfIntervalCount,
xfPMACMInterval15m512QAMStrong PerfIntervalCount,
xfPMACMInterval15m512QAMStd PerfIntervalCount,
xfPMACMInterval15m512QAMLight PerfIntervalCount,
xfPMACMInterval15m1024QAMStrong PerfIntervalCount,
xfPMACMInterval15m1024QAMStd PerfIntervalCount,
xfPMACMInterval15m1024QAMLight PerfIntervalCount,
xfPMACMInterval15m2048QAMStrong PerfIntervalCount,
xfPMACMInterval15m2048QAMStd PerfIntervalCount,
xfPMACMInterval15m2048QAMLight PerfIntervalCount,
xfPMACMInterval15m4096QAMStrong PerfIntervalCount,
xfPMACMInterval15m4096QAMStd PerfIntervalCount,
xfPMACMInterval15m4096QAMLight PerfIntervalCount,
xfPMACMInterval15mValidData TruthValue,
xfPMACMInterval15m8192QAMStrong PerfIntervalCount,
xfPMACMInterval15m8192QAMStd PerfIntervalCount,
xfPMACMInterval15m8192QAMLight PerfIntervalCount,
xfPMACMInterval15m16384QAMStrong PerfIntervalCount,
xfPMACMInterval15m16384QAMStd PerfIntervalCount,
xfPMACMInterval15m16384QAMLight PerfIntervalCount
}
xfPMACMInterval15mIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for which
the set of statistics is available. The interval identified by 1
is the most recently completed 15 minute interval, and the interval
identified by N is the interval immediately preceding the one
identified by N-1."
::= { xfRLPMACMInterval15mEntry 1 }
xfPMACMInterval15m4QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 2 }
xfPMACMInterval15m4QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 3 }
xfPMACMInterval15m4QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 4 }
xfPMACMInterval15m16QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 5 }
xfPMACMInterval15m16QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 6 }
xfPMACMInterval15m16QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 7 }
xfPMACMInterval15m32QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 8 }
xfPMACMInterval15m32QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 9 }
xfPMACMInterval15m32QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 10 }
xfPMACMInterval15m64QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 11 }
xfPMACMInterval15m64QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 12 }
xfPMACMInterval15m64QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 13 }
xfPMACMInterval15m128QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 14 }
xfPMACMInterval15m128QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 15 }
xfPMACMInterval15m128QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 16 }
xfPMACMInterval15m256QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 17 }
xfPMACMInterval15m256QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 18 }
xfPMACMInterval15m256QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 19 }
xfPMACMInterval15m512QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 20 }
xfPMACMInterval15m512QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 21 }
xfPMACMInterval15m512QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 22 }
xfPMACMInterval15m1024QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 23 }
xfPMACMInterval15m1024QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 24 }
xfPMACMInterval15m1024QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 25 }
xfPMACMInterval15m2048QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 26 }
xfPMACMInterval15m2048QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 27 }
xfPMACMInterval15m2048QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 28 }
xfPMACMInterval15m4096QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 29 }
xfPMACMInterval15m4096QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 30 }
xfPMACMInterval15m4096QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 31 }
xfPMACMInterval15mValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates whether the data for this interval is valid."
::= { xfRLPMACMInterval15mEntry 32 }
xfPMACMInterval15m8192QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 33 }
xfPMACMInterval15m8192QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 34 }
xfPMACMInterval15m8192QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 35 }
xfPMACMInterval15m16384QAMStrong OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 36 }
xfPMACMInterval15m16384QAMStd OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 37 }
xfPMACMInterval15m16384QAMLight OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval count."
::= { xfRLPMACMInterval15mEntry 38 }
------------------------------------------------------------------------------
-- xfRLPMMimoCurrentTable
------------------------------------------------------------------------------
xfRLPMMimoCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLPMMimoCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for RLT MIMO Current performance data."
::= { xfRadioLinkRltPmObjects 7 }
xfRLPMMimoCurrentEntry OBJECT-TYPE
SYNTAX XfRLPMMimoCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the xfRLPMMimoCurrentTable."
INDEX { ifIndex }
::= { xfRLPMMimoCurrentTable 1 }
XfRLPMMimoCurrentEntry ::=
SEQUENCE
{
xfPMPerfCurrentEta INTEGER,
xfPMPerfEtaMinLast7days INTEGER,
xfPMPerfEtaMaxLast7days INTEGER
}
xfPMPerfCurrentEta OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Performance Monitoring for Current MIMO Eta Value."
::= { xfRLPMMimoCurrentEntry 1 }
xfPMPerfEtaMinLast7days OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate ETA Min level for the last 7 days."
::= { xfRLPMMimoCurrentEntry 2 }
xfPMPerfEtaMaxLast7days OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate ETA Max level for the last 7 days."
::= { xfRLPMMimoCurrentEntry 3 }
------------------------------------------------------------------------------
-- xfRLPMMimoCurrent24hTable
------------------------------------------------------------------------------
xfRLPMMimoCurrent24hTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLPMMimoCurrent24hEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Counters for Eta in current 24h."
::= { xfRadioLinkRltPmObjects 8 }
xfRLPMMimoCurrent24hEntry OBJECT-TYPE
SYNTAX XfRLPMMimoCurrent24hEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the xfRLPMMimoCurrent24hTable."
INDEX { ifIndex }
::= { xfRLPMMimoCurrent24hTable 1 }
XfRLPMMimoCurrent24hEntry ::=
SEQUENCE
{
xfPMPerfCurrent24hElapsedTime Counter32,
xfPMPerfCurrent24hEtaMin INTEGER,
xfPMPerfCurrent24hEtaMax INTEGER
}
xfPMPerfCurrent24hElapsedTime OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the
beginning of the current error-measurement period. "
::= { xfRLPMMimoCurrent24hEntry 1 }
xfPMPerfCurrent24hEtaMin OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Performance Monitoring for MIMO Eta Min Value in Current 24h."
::= { xfRLPMMimoCurrent24hEntry 2 }
xfPMPerfCurrent24hEtaMax OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Performance Monitoring for Current MIMO 24h Eta Max Value."
::= { xfRLPMMimoCurrent24hEntry 3 }
------------------------------------------------------------------------------
-- xfRLPMMimoInterval24hTable
------------------------------------------------------------------------------
xfRLPMMimoInterval24hTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLPMMimoInterval24hEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Performance Monitoring for MIMO Eta Min Value in Interval of 24h."
::= { xfRadioLinkRltPmObjects 9 }
xfRLPMMimoInterval24hEntry OBJECT-TYPE
SYNTAX XfRLPMMimoInterval24hEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the xfRLPMMimoInterval24hTable."
INDEX { ifIndex }
::= { xfRLPMMimoInterval24hTable 1 }
XfRLPMMimoInterval24hEntry ::=
SEQUENCE
{
xfPMPerfInterval24hValidData INTEGER,
xfPMPerfInterval24hEtaMin INTEGER,
xfPMPerfInterval24hEtaMax INTEGER
}
xfPMPerfInterval24hValidData OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates whether the data for this interval is valid."
::= { xfRLPMMimoInterval24hEntry 1 }
xfPMPerfInterval24hEtaMin OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Performance Monitoring for MIMO Eta Min Value in Interval of 24h."
::= { xfRLPMMimoInterval24hEntry 2 }
xfPMPerfInterval24hEtaMax OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Performance Monitoring for MIMO Eta Max Value in Interval of 24h."
::= { xfRLPMMimoInterval24hEntry 3 }
------------------------------------------------------------------------------
-- xfRLPMMimoCurrent15mTable
------------------------------------------------------------------------------
xfRLPMMimoCurrent15mTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLPMMimoCurrent15mEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Counters for Eta MIMO Current 15m table."
::= { xfRadioLinkRltPmObjects 10 }
xfRLPMMimoCurrent15mEntry OBJECT-TYPE
SYNTAX XfRLPMMimoCurrent15mEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the table."
INDEX { ifIndex }
::= { xfRLPMMimoCurrent15mTable 1 }
XfRLPMMimoCurrent15mEntry ::=
SEQUENCE
{
xfPMPerfCurrent15mElapsedTime Counter32,
xfPMPerfCurrent15mEtaMin INTEGER,
xfPMPerfCurrent15mEtaMax INTEGER
}
xfPMPerfCurrent15mElapsedTime OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the
beginning of the current error-measurement period"
::= { xfRLPMMimoCurrent15mEntry 1 }
xfPMPerfCurrent15mEtaMin OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Performance Monitoring for MIMO Eta Min Value in Current 15m."
::= { xfRLPMMimoCurrent15mEntry 2 }
xfPMPerfCurrent15mEtaMax OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Performance Monitoring for MIMO Eta Max Value in Current 15m."
::= { xfRLPMMimoCurrent15mEntry 3 }
------------------------------------------------------------------------------
-- xfRLPMMimoInterval15mTable
------------------------------------------------------------------------------
xfRLPMMimoInterval15mTable OBJECT-TYPE
SYNTAX SEQUENCE OF XfRLPMMimoInterval15mEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Counters for Eta MIMO for Interval 15m."
::= { xfRadioLinkRltPmObjects 11 }
xfRLPMMimoInterval15mEntry OBJECT-TYPE
SYNTAX XfRLPMMimoInterval15mEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the table."
INDEX { ifIndex, xfPMPerfInterval15mIntervalNumber }
::= { xfRLPMMimoInterval15mTable 1 }
XfRLPMMimoInterval15mEntry ::=
SEQUENCE
{
xfPMPerfInterval15mIntervalNumber INTEGER,
xfPMPerfInterval15mEtaMin INTEGER,
xfPMPerfInterval15mEtaMax INTEGER,
xfPMPerfInterval15mValidData INTEGER
}
xfPMPerfInterval15mIntervalNumber OBJECT-TYPE
SYNTAX INTEGER(1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the interval for which
the set of statistics is available. The interval identified by 1
is the most recently completed 15 minute interval, and the interval
identified by N is the interval immediately preceding the one
identified by N-1."
::= { xfRLPMMimoInterval15mEntry 1 }
xfPMPerfInterval15mEtaMin OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Performance Monitoring for MIMO Eta Min Value in Interval 15m."
::= { xfRLPMMimoInterval15mEntry 2 }
xfPMPerfInterval15mEtaMax OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Performance Monitoring for MIMO Eta Max Value in Interval 15m."
::= { xfRLPMMimoInterval15mEntry 3 }
xfPMPerfInterval15mValidData OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates whether the data for this interval is valid."
::= { xfRLPMMimoInterval15mEntry 4 }
--
------------------------------------------------------------------------------
-- xfRadioLinkRltConformance
------------------------------------------------------------------------------
--
xfRadioLinkRltCompliances OBJECT IDENTIFIER ::= { xfRadioLinkRltConformance 1 }
xfRadioLinkRltGroups OBJECT IDENTIFIER ::= { xfRadioLinkRltConformance 2 }
xfRadioLinkRltFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which implement everything."
MODULE -- This Module
MANDATORY-GROUPS { xfRadioLinkRltCompleteGroup }
::= { xfRadioLinkRltCompliances 1 }
xfRadioLinkRltCompleteGroup OBJECT-GROUP
OBJECTS
{
cgIfIndex,
cgTypeIndex,
xfIfStatus,
liEntLogicalIndex,
liIfIndex,
xfLIName,
xfLIIfDescr,
xfCarrierTermDistinguishedName,
xfCarrierTermLabel,
xfCarrierTermOperStatus,
xfCarrierTermRadioFrameId,
xfCarrierTermPreamble,
xfCarrierTermSelectedMinACM,
xfCarrierTermActualACM,
xfCarrierTermSelectedMaxACM,
xfCarrierTermCapabilitiesLastChange,
xfCarrierTermReferenceSEC,
xfCarrierTermWantedLicensedCapacity,
xfCarrierTermActualLicensedCapacity,
xfCarrierTermActualCapacity,
xfCarrierTermPolarization,
xfCarrierTermXPICOperStatus,
xfCarrierTermMIMOOperStatus,
xfCarrierTermSNIR,
xfCarrierTermXPI,
xfCarrierTermReset,
xfCarrierTermRestore,
xfCarrierTermAutoRemoveLoopEnable,
xfCarrierTermBerAlarmThreshold,
xfCarrierTermActualRxACM,
xfCarrierTermFeCTSeverity,
xfRadioFrameId,
xfChannelSpacing,
xfFrameFormatType,
xfMinACMCapacity,
xfMaxACMCapacity,
xfACMProfile,
xfACMIndex,
xfACMCapacity,
rltEntLogicalIndex,
xfRLTDistinguishedName,
xfRLTIpAddress,
xfRLTIPv6Address,
xfRLTNeName,
xfRLTNeType,
xfRLTId,
xfRLTExpectedFarEndId,
xfRLTFarEndIdCheck,
xfRLTStatus,
xfRLTMode,
xfRLTActualTXTotalCapacity,
xfRLTActualTXPacketCapacity,
xfRLTLimitedTotalCapacity,
xfRLTRltSeverity,
xfRLTCapability,
xfRLTInventoryLastChange,
xfRLTCpriMode,
xfRLTReset,
xfRLTMeasuredHopLength,
trEntLogicalIndex,
xfTDMEnable,
xfRLTDMIfIndex,
xfActualTDMCapacity,
xfWantedTDMAllocation,
xfActualTDMAllocation,
xfTDMIfAlarms,
xfTDMRxLoop,
xfTDMDistinguishedName,
xfTDMMaxTributaries,
xfTDMHopLength,
xfCGIfIndex,
xfCGIfMinSpeed,
xfCGIfMaxSpeed,
xfCGIfRCNum,
xfCGIfAlarms,
xfCGIfHopViewStatus,
xpicPairEntLogicalIIndex,
xfXPICPairAdminStatus,
xfXPICPairNumber,
xfXPICPairRecovery,
xfXPICPairRestore,
xfXPICCTmember1,
xfXPICCTmember2,
xfXPICAutoRestore,
xfXpicPairIndex,
mimoGroupEntLogicalIIndex,
xfMIMOGroupAdminStatus,
xfMIMOGroupNumber,
xfMIMOGroupRecovery,
xfMIMOGroupRestore,
xfMIMOCTmember1,
xfMIMOCTmember2,
xfMIMOCTmember3,
xfMIMOCTmember4,
xfPMTimeElapsed,
xfPMCurrentES,
xfPMCurrentSES,
xfPMCurrentBBE,
xfPMCurrentUAS,
xfPMCurrentBB,
xfPMPerfReset,
xfPMCurrentESR,
xfPMCurrentSESR,
xfPMCurrentBBER,
xfPMACMSetThreshold15m,
xfPMACMSetThreshold24h,
xfPMACMResetThreshold15m,
xfPMACMStatus,
xfPMACMValidData,
xfPMACMCurrent24h4QAMStrong,
xfPMACMCurrent24h4QAMStd,
xfPMACMCurrent24h4QAMLight,
xfPMACMCurrent24h16QAMStrong,
xfPMACMCurrent24h16QAMStd,
xfPMACMCurrent24h16QAMLight,
xfPMACMCurrent24h32QAMStrong,
xfPMACMCurrent24h32QAMStd,
xfPMACMCurrent24h32QAMLight,
xfPMACMCurrent24h64QAMStrong,
xfPMACMCurrent24h64QAMStd,
xfPMACMCurrent24h64QAMLight,
xfPMACMCurrent24h128QAMStrong,
xfPMACMCurrent24h128QAMStd,
xfPMACMCurrent24h128QAMLight,
xfPMACMCurrent24h256QAMStrong,
xfPMACMCurrent24h256QAMStd,
xfPMACMCurrent24h256QAMLight,
xfPMACMCurrent24h512QAMStrong,
xfPMACMCurrent24h512QAMStd,
xfPMACMCurrent24h512QAMLight,
xfPMACMCurrent24h1024QAMStrong,
xfPMACMCurrent24h1024QAMStd,
xfPMACMCurrent24h1024QAMLight,
xfPMACMCurrent24h2048QAMStrong,
xfPMACMCurrent24h2048QAMStd,
xfPMACMCurrent24h2048QAMLight,
xfPMACMCurrent24h4096QAMStrong,
xfPMACMCurrent24h4096QAMStd,
xfPMACMCurrent24h4096QAMLight,
xfPMACMCurrent24h8192QAMStrong,
xfPMACMCurrent24h8192QAMStd,
xfPMACMCurrent24h8192QAMLight,
xfPMACMCurrent24h16384QAMStrong,
xfPMACMCurrent24h16384QAMStd,
xfPMACMCurrent24h16384QAMLight,
xfPMACMInterval24h4QAMStrong,
xfPMACMInterval24h4QAMStd,
xfPMACMInterval24h4QAMLight,
xfPMACMInterval24h16QAMStrong,
xfPMACMInterval24h16QAMStd,
xfPMACMInterval24h16QAMLight,
xfPMACMInterval24h32QAMStrong,
xfPMACMInterval24h32QAMStd,
xfPMACMInterval24h32QAMLight,
xfPMACMInterval24h64QAMStrong,
xfPMACMInterval24h64QAMStd,
xfPMACMInterval24h64QAMLight,
xfPMACMInterval24h128QAMStrong,
xfPMACMInterval24h128QAMStd,
xfPMACMInterval24h128QAMLight,
xfPMACMInterval24h256QAMStrong,
xfPMACMInterval24h256QAMStd,
xfPMACMInterval24h256QAMLight,
xfPMACMInterval24h512QAMStrong,
xfPMACMInterval24h512QAMStd,
xfPMACMInterval24h512QAMLight,
xfPMACMInterval24h1024QAMStrong,
xfPMACMInterval24h1024QAMStd,
xfPMACMInterval24h1024QAMLight,
xfPMACMInterval24h2048QAMStrong,
xfPMACMInterval24h2048QAMStd,
xfPMACMInterval24h2048QAMLight,
xfPMACMInterval24h4096QAMStrong,
xfPMACMInterval24h4096QAMStd,
xfPMACMInterval24h4096QAMLight,
xfPMACMInterval24hValidData,
xfPMACMInterval24h8192QAMStrong,
xfPMACMInterval24h8192QAMStd,
xfPMACMInterval24h8192QAMLight,
xfPMACMInterval24h16384QAMStrong,
xfPMACMInterval24h16384QAMStd,
xfPMACMInterval24h16384QAMLight,
xfPMACMCurrent15m4QAMStrong,
xfPMACMCurrent15m4QAMStd,
xfPMACMCurrent15m4QAMLight,
xfPMACMCurrent15m16QAMStrong,
xfPMACMCurrent15m16QAMStd,
xfPMACMCurrent15m16QAMLight,
xfPMACMCurrent15m32QAMStrong,
xfPMACMCurrent15m32QAMStd,
xfPMACMCurrent15m32QAMLight,
xfPMACMCurrent15m64QAMStrong,
xfPMACMCurrent15m64QAMStd,
xfPMACMCurrent15m64QAMLight,
xfPMACMCurrent15m128QAMStrong,
xfPMACMCurrent15m128QAMStd,
xfPMACMCurrent15m128QAMLight,
xfPMACMCurrent15m256QAMStrong,
xfPMACMCurrent15m256QAMStd,
xfPMACMCurrent15m256QAMLight,
xfPMACMCurrent15m512QAMStrong,
xfPMACMCurrent15m512QAMStd,
xfPMACMCurrent15m512QAMLight,
xfPMACMCurrent15m1024QAMStrong,
xfPMACMCurrent15m1024QAMStd,
xfPMACMCurrent15m1024QAMLight,
xfPMACMCurrent15m2048QAMStrong,
xfPMACMCurrent15m2048QAMStd,
xfPMACMCurrent15m2048QAMLight,
xfPMACMCurrent15m4096QAMStrong,
xfPMACMCurrent15m4096QAMStd,
xfPMACMCurrent15m4096QAMLight,
xfPMACMCurrent15m8192QAMStrong,
xfPMACMCurrent15m8192QAMStd,
xfPMACMCurrent15m8192QAMLight,
xfPMACMCurrent15m16384QAMStrong,
xfPMACMCurrent15m16384QAMStd,
xfPMACMCurrent15m16384QAMLight,
xfPMACMInterval15mIntervalNumber,
xfPMACMInterval15m4QAMStrong,
xfPMACMInterval15m4QAMStd,
xfPMACMInterval15m4QAMLight,
xfPMACMInterval15m16QAMStrong,
xfPMACMInterval15m16QAMStd,
xfPMACMInterval15m16QAMLight,
xfPMACMInterval15m32QAMStrong,
xfPMACMInterval15m32QAMStd,
xfPMACMInterval15m32QAMLight,
xfPMACMInterval15m64QAMStrong,
xfPMACMInterval15m64QAMStd,
xfPMACMInterval15m64QAMLight,
xfPMACMInterval15m128QAMStrong,
xfPMACMInterval15m128QAMStd,
xfPMACMInterval15m128QAMLight,
xfPMACMInterval15m256QAMStrong,
xfPMACMInterval15m256QAMStd,
xfPMACMInterval15m256QAMLight,
xfPMACMInterval15m512QAMStrong,
xfPMACMInterval15m512QAMStd,
xfPMACMInterval15m512QAMLight,
xfPMACMInterval15m1024QAMStrong,
xfPMACMInterval15m1024QAMStd,
xfPMACMInterval15m1024QAMLight,
xfPMACMInterval15m2048QAMStrong,
xfPMACMInterval15m2048QAMStd,
xfPMACMInterval15m2048QAMLight,
xfPMACMInterval15m4096QAMStrong,
xfPMACMInterval15m4096QAMStd,
xfPMACMInterval15m4096QAMLight,
xfPMACMInterval15mValidData,
xfPMACMInterval15m8192QAMStrong,
xfPMACMInterval15m8192QAMStd,
xfPMACMInterval15m8192QAMLight,
xfPMACMInterval15m16384QAMStrong,
xfPMACMInterval15m16384QAMStd,
xfPMACMInterval15m16384QAMLight,
xfRLWANIfIndex,
xfRLWANDistinguishedName,
xfRLWANCompAdminStatus,
xfRLWANCompConnStatus,
xfRLWANMlhcMplsMode,
xfRLWANMlhcOperStatus,
xfRLWANPlcOperStatus,
xfRLWANActualCapacity,
xfRLWANLimitedCapacity,
xfRLTMHIndex,
xfRLTModuleIndex,
xfRLTEntPhysicalIndex,
xfRLTPhysicalCointainedIn,
xfRLTPhysicalParentRelPos,
xfRLTEntityPhysicalDescr,
xfRLTModuleSlotPosition,
xfRLTNEDistinguishedName,
xfRLTFEDistinguishedName,
xfRLTInterfaceIndex,
xfRLTHighestSeverityAlarm,
xfRLTProtIndex,
xfRLTProtectionSwitchMode,
xfRLTProtectionStatus,
xfRLTRevertivePreferredTX,
xfRLTProtectionWaitToRestoreTime,
xfRLTFadeNotificationTimer,
xfRLTManualSwitchCommand,
xfRLTTxSwitchOverConfiguration,
xfRLTTxSwitchOverAlarmReset,
xfRLTNumOfRLPSwitch,
xfRLTEnhancedACMProtectionMode,
xfRLTEnhancedACMProtectionOperStatus,
xfRLTEncryptionIndex,
xfRLTEncryptionAdminStatus,
xfRLTEncryptionOperStatus,
xfRLTEncryptionMasterKey,
xfPMPerfCurrentEta,
xfPMPerfEtaMinLast7days,
xfPMPerfEtaMaxLast7days,
xfPMPerfCurrent24hElapsedTime,
xfPMPerfCurrent24hEtaMin,
xfPMPerfCurrent24hEtaMax,
xfPMPerfInterval24hValidData,
xfPMPerfInterval24hEtaMin,
xfPMPerfInterval24hEtaMax,
xfPMPerfCurrent15mElapsedTime,
xfPMPerfCurrent15mEtaMin,
xfPMPerfCurrent15mEtaMax,
xfPMPerfInterval15mIntervalNumber,
xfPMPerfInterval15mEtaMin,
xfPMPerfInterval15mEtaMax,
xfPMPerfInterval15mValidData
}
STATUS current
DESCRIPTION
"A collection of all current objects in this MIB module"
::= { xfRadioLinkRltGroups 1 }
END