mibs/MIBS/extreme/BROCADE-MODULE-CPU-UTIL-MIB
2023-12-05 12:25:34 +01:00

141 lines
4.3 KiB
Plaintext

-- MIB File: BROCADE-MODULE-CPU-UTIL-MIB.mib
-- *********************************************************************
-- BROCADE-MODULE-CPU-UTIL-MIB.mib: Extreme module CPU utilization MIB
--
-- Copyright (c) 2018 Extreme Networks, Inc.
-- All rights reserved.
-- *********************************************************************
BROCADE-MODULE-CPU-UTIL-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,Integer32, Gauge32
FROM SNMPv2-SMI
bcsiModules
FROM Brocade-REG-MIB;
brocadeModuleCpuUtilMIB MODULE-IDENTITY
LAST-UPDATED "201805291200Z" -- May 29, 2018 12:00pm
ORGANIZATION "Extreme Networks, Inc."
CONTACT-INFO
"Postal: Extreme Networks, Inc.
6480 Via Del Oro
San Jose, CA 95119 USA
Phone: +1 408 579-2800
E-mail: support@extremenetworks.com
WWW: http://www.extremenetworks.com"
DESCRIPTION
"This MIB module supports the per module CPU utilization."
REVISION "201805291200Z" -- May 29, 2018 12:00pm
DESCRIPTION
"Updated ORGANIZATION and CONTACT-INFO with Extreme Networks"
REVISION "201611250000Z" -- 25 November 2016
DESCRIPTION
"Initial version of this MIB module."
::= { bcsiModules 12 }
bcsiModuleCpuUtilNotifications OBJECT IDENTIFIER
::= { brocadeModuleCpuUtilMIB 0 }
bcsiModuleCpuUtilObjects OBJECT IDENTIFIER
::= { brocadeModuleCpuUtilMIB 1 }
bcsiModuleCpuUtilConformance OBJECT IDENTIFIER
::= { brocadeModuleCpuUtilMIB 2 }
bcsiModuleCpuUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF BcsiModuleCpuUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to list per module CPU utilization in the device."
::= { bcsiModuleCpuUtilObjects 1 }
bcsiModuleCpuUtilEntry OBJECT-TYPE
SYNTAX BcsiModuleCpuUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the CPU utilization table."
INDEX {
bcsiModuleCpuUtilSlotNum,
bcsiModuleCpuUtilInterval
}
::= { bcsiModuleCpuUtilTable 1 }
BcsiModuleCpuUtilEntry ::= SEQUENCE {
bcsiModuleCpuUtilSlotNum
Integer32,
bcsiModuleCpuUtilInterval
Integer32,
bcsiModuleCpuUtil100thPercent
Gauge32
}
bcsiModuleCpuUtilSlotNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The slot number of the module which contains the CPU.
Slot number in SLX are: MM1 = 1, MM2 = 2, LC1 = 3, LC2 =4 and so on."
::= { bcsiModuleCpuUtilEntry 1 }
bcsiModuleCpuUtilInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value, in seconds, for this utilization. It supports
utilization for the last 60 sec, 300 sec and 900 sec interval."
::= { bcsiModuleCpuUtilEntry 2 }
bcsiModuleCpuUtil100thPercent OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statistical CPU utilization in units of one-hundredth
of a percent. For example-a value of 200 indicates 2 percent utilization."
::= { bcsiModuleCpuUtilEntry 3 }
--
-- Conformance
--
bcsiModuleCpuUtilCompliances OBJECT IDENTIFIER
::= { bcsiModuleCpuUtilConformance 1 }
bcsiModuleCpuUtilGroups OBJECT IDENTIFIER
::= { bcsiModuleCpuUtilConformance 2 }
bcsiModuleCpuUtilCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which
implement BROCADE-MODULE-CPU-UTIL-MIB."
MODULE MANDATORY-GROUPS { bcsiModuleCpuUtilizationGroup }
::= { bcsiModuleCpuUtilCompliances 1 }
--
-- Units of Conformance
--
bcsiModuleCpuUtilizationGroup OBJECT-GROUP
OBJECTS {
bcsiModuleCpuUtilSlotNum,
bcsiModuleCpuUtilInterval,
bcsiModuleCpuUtil100thPercent
}
STATUS current
DESCRIPTION
"A collection of objects for per module CPU utilization value."
::= { bcsiModuleCpuUtilGroups 1 }
END
-- ========================================================================================