mibs/MIBS/extreme/BROCADE-UDLD-MIB
2023-12-05 12:25:34 +01:00

124 lines
3.6 KiB
Plaintext

-- MIB File: BROCADE-UDLD-MIB.mib
-- *********************************************************************
-- BROCADE-UDLD-MIB.mib: Extreme UniDirectional Link Detection (UDLD) MIB
--
-- Septermber 2016
--
-- Copyright (c) 2018 Extreme Networks, Inc.
-- All rights reserved.
--
-- *********************************************************************
BROCADE-UDLD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
ifIndex
FROM IF-MIB
bcsiModules
FROM Brocade-REG-MIB
;
brocadeUdldMIB MODULE-IDENTITY
LAST-UPDATED "201805291200Z" -- May 29, 2018 12:00pm
ORGANIZATION "Extreme Networks, Inc."
CONTACT-INFO
"Postal: Extreme Networks, Inc.
6480 Via Del Oro
San Jose, CA 95119 USA
Phone: +1 408 579-2800
E-mail: support@extremenetworks.com
WWW: http://www.extremenetworks.com"
DESCRIPTION
"This MIB module supports UDLD related notifications."
REVISION "201805291200Z" -- May 29, 2018 12:00pm
DESCRIPTION
"Updated ORGANIZATION and CONTACT-INFO with Extreme Networks"
REVISION "201609280000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { bcsiModules 9 }
bcsiUdldNotifications OBJECT IDENTIFIER ::= { brocadeUdldMIB 0 }
bcsiUdldObjects OBJECT IDENTIFIER ::= { brocadeUdldMIB 1 }
bcsiUdldConformance OBJECT IDENTIFIER ::= { brocadeUdldMIB 2 }
-- Objects
bcsiUdldNotifObjects OBJECT IDENTIFIER ::= { bcsiUdldObjects 1 }
bcsiUdldNotifMessage OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..255))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Generic Notification message string for UDLD notifications."
::= { bcsiUdldNotifObjects 1 }
-- Notifications
bcsiUdldNotifLinkDown NOTIFICATION-TYPE
OBJECTS { ifIndex, bcsiUdldNotifMessage }
STATUS current
DESCRIPTION
"The SNMP trap that is generated when UDLD port link status
has changed to down."
--#TYPE "Extreme Notification: UDLD Port Link Down"
--#SUMMARY "%s."
--#ARGUMENTS { 1 }
--#SEVERITY NOTIFICATIONS
--#STATE OPERATIONAL
::= { bcsiUdldNotifications 1 }
bcsiUdldNotifLinkUp NOTIFICATION-TYPE
OBJECTS { ifIndex, bcsiUdldNotifMessage }
STATUS current
DESCRIPTION
"The SNMP trap that is generated when UDLD port link status
has changed to up."
--#TYPE "Extreme Notification: UDLD Port Link Up"
--#SUMMARY "%s."
--#ARGUMENTS { 1 }
--#SEVERITY NOTIFICATIONS
--#STATE OPERATIONAL
::= { bcsiUdldNotifications 2 }
--
-- Conformance
--
bcsiUdldCompliances OBJECT IDENTIFIER
::= { bcsiUdldConformance 1 }
bcsiUdldGroups OBJECT IDENTIFIER
::= { bcsiUdldConformance 2 }
bcsiUdldCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which
implement BROCADE-UDLD-MIB."
MODULE MANDATORY-GROUPS { bcsiUdldNotifGroup }
::= { bcsiUdldCompliances 1 }
--
-- Units of Conformance
--
bcsiUdldNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS {
bcsiUdldNotifLinkDown,
bcsiUdldNotifLinkUp
}
STATUS current
DESCRIPTION
"A collection of notifications for UDLD MIB."
::= { bcsiUdldGroups 1 }
END