mibs/MIBS/extreme/EXTREME-SYSTEM-MIB
2023-12-05 12:25:34 +01:00

2492 lines
85 KiB
Plaintext

-- ################################################################################
EXTREME-SYSTEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
TEXTUAL-CONVENTION FROM SNMPv2-TC
NOTIFICATION-TYPE FROM SNMPv2-SMI
MODULE-IDENTITY FROM SNMPv2-SMI
OBJECT-TYPE FROM SNMPv2-SMI
Integer32, Unsigned32 FROM SNMPv2-SMI
TruthValue FROM SNMPv2-TC
RowStatus FROM SNMPv2-TC
DisplayString FROM RFC1213-MIB
extremeAgent FROM EXTREME-BASE-MIB
PortList FROM EXTREME-BASE-MIB
sysDescr,sysUpTime, ifDescr FROM RFC1213-MIB
MacAddress FROM SNMPv2-TC
IpAddress FROM SNMPv2-SMI
InetAddressType, InetAddress FROM INET-ADDRESS-MIB;
extremeSystem MODULE-IDENTITY
LAST-UPDATED "202002121739Z" -- Wed Feb 12 17:39:00 UTC 2020
ORGANIZATION "Extreme Networks, Inc."
CONTACT-INFO
"Postal: Extreme Networks, Inc.
6480 Via Del Oro
San Jose, CA 95119 USA
Phone: +1 408 579-2800
E-mail: support@extremenetworks.com
WWW: http://www.extremenetworks.com"
DESCRIPTION "Extreme System objects: objects common to all platforms"
REVISION "202002121739Z" -- Wed Feb 12 17:39:00 UTC 2020
DESCRIPTION "Add V300 SlotType entries"
REVISION "201909042120Z" -- Wed Sep 4 21:20:00 UTC 2019
DESCRIPTION "Add X465-24XE, X465-24S and X465i-48W SlotType entries"
REVISION "201809262302Z" -- Fri Sep 26 23:02 UTC 2018
DESCRIPTION "Add X725 SlotType"
REVISION "201908051031Z" -- Mon Aug 5 10:31:29 UTC 2019
DESCRIPTION "Add X435 SlotType entries"
REVISION "201809141531Z" -- Fri Sep 14 15:31 UTC 2018
DESCRIPTION "Add X465 SlotType entries"
REVISION "201807241400Z" -- Tue Jul 24 14:00 IST 2018
DESCRIPTION "Updated extremeSaveConfiguration object description"
REVISION "201807021010Z" -- Mon Jul 2 10:10 IST 2018
DESCRIPTION "Modified platforms in according with SlotType value 625
626"
REVISION "201806071410Z" -- Thu Jun 7 14:10 UTC 2018
DESCRIPTION "Remove unsupported slotType entries"
REVISION "201803011631Z" -- Thu Mar 1 16:31 UTC 2018
DESCRIPTION "Added new SlotType entries for X590 models"
REVISION "201708291948Z" -- Fri Sep 29 19:48 UTC 2017
DESCRIPTION "Added auto-save configuration object"
REVISION "201706280338Z" -- Wed Jun 28 03:38 UTC 2017
DESCRIPTION "Added an existing platform type vm386EXOS which was missing in this list"
REVISION "201706141501Z" -- Wed June 14 15:01:10 UTC 2017
DESCRIPTION "Added new slot types for BPEs"
REVISION "201706011630Z" -- Thu Jun 1 16:30 UTC 2017
DESCRIPTION "Added new SlotType entry for WhiteBoxes"
REVISION "201608051809Z" -- Fri Aug 5 18:09:52 UTC 2016
DESCRIPTION "Added new slot types for new halfcat cards x460G2-24p-24hp and x460G2-24t-24ht"
REVISION "201607250810Z" -- Mon Jul 25 8:10 UTC 2016
DESCRIPTION "Added new slot type for x460-G2-16mp-32p-10GE4 platform"
REVISION "201603290000Z" -- Tue Mar 29 2016
DESCRIPTION "Added new SlotType entries X690 models"
REVISION "201503061955Z" -- Fri Mar 06 19:55 GMT 2015
DESCRIPTION "Added new slot types for new cards bdxa-48t, bdxa-48x"
::= { extremeAgent 1 }
SlotType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The type of the slot. It is used both for the configured
as well as the inserted slot types."
SYNTAX INTEGER {
none(1),
fe32(2),
g4x(3),
g6x(4),
fe32fx(5),
msm(6),
f48ti(7),
g8xi(8),
g8ti(9),
g12sxi(10),
g12ti(11),
msm64i(18),
alpine3808(19),
alpine3804(20),
fm32t(21),
gm4x(22),
gm4sx(23),
gm4t(24),
wdm8(25),
fm24f(26),
fm24sf(27),
fm24te(28),
f96ti(29),
wdm4(30),
f32fi(31),
tenGig(32),
tenGigLR(33),
g16x3(34),
g24t3(35),
gm16x3(36),
gm16t3(37),
fm16t3(38),
fm32p(39),
fm8v(50), -- vdsl blade
wm4t1(51), -- 4port t1
wm4t3(52), -- 4port t3
wm1t3(53), -- 1port t3
wm4e1(54), -- 4port e1
alpine3802(55),
p3c(101),
p12c(102),
arm(103),
mpls(104),
sma(105),
p48c(106),
a3c(107),
a12c(108),
pxm(200),
s300fixed(201),
msm3(202),
msm1(203),
msm1xl(204),
s300expansion(301),
g60t(400),
g60x(401),
teng6x(402),
vm386EXOS(406),
msm-g8x(414),
g8x(415),
g48t(416),
g48p(417),
g24x(418),
teng4x(419),
teng2x(420),
g20x(421),
teng2h(422),
x450-24x(423),
x450-24t(424),
msm5(425),
msm5r(426),
gm20t(427),
gm20xt(428),
gm20xtr(429),
xm2x(430), -- 10G2X
xm2xr(431), -- 10G2XR
msm6r(432),
g48te(433),
g48ta(434),
g48pe(435),
g48x(437),
x450a-24t(439),
x450e-24p(440),
x450a-48t(442),
x450e-48p(443),
x450a-24x(444),
x450a-24tdc(445),
x450a-24xdc(446),
msm-48(447),
teng4ca(448),
teng4xa(449),
g48tc(450),
g48te2(451),
g48xc(452),
g24xc(453),
tenG4xc(454),
tenG8xc(455),
msms48c(456),
g8xc(457),
tenG1xc(458),
g48tcPoE(459),
g48te2PoE(460),
x450a-48tdc(461),
x250e-24t(462),
x250e-24p(463),
x250e-48t(464),
x250e-48p(465),
x250e-24x(466),
x250e-24xtaa(467),
x250e-24tdc(468),
x250e-48tdc(469),
x250e-24xdc(470),
x150-24t(471),
x150-24tdc(472),
x150-24p(473),
x150-48t(474),
x150-48tdc(475),
x150-48p(476),
x150-24x(477),
x150-24xdc(478),
xm2hr(480),
x350-24t(481),
x350-48t(482),
x650-24t(483),
x650-24x(484),
x650-24tG4X(485),
x650-24xG4X(486),
x650-24tG4X10G2S(487),
x650-24xG4X10G2S(488),
x650-24t10G8X10G2S(489),
x650-24x10G8X10G2S(490),
x650-24t64G2S(491),
x650-24x64G2S(492),
x650-24t64G4S(493),
x650-24x64G4S(494),
mmbase(496),
mmadv(497),
gm40xb(498),
xm8xb(500),
x8900msm128(503),
x8900tenG24xc(504),
x8900tenG8xm(505),
x8900g48tm(506),
x8900g48xm(507),
x8900g96tc(508),
x8900g48tmPoE(509),
nwie450a(510),
x480-24x(511),
x480-48x(512),
x480-48t(513),
x480-24x10G2S(514),
x480-48x10G2S(515),
x480-48t10G2S(516),
x480-24x10G4X(517),
x480-48x10G4X(518),
x480-48t10G4X(519),
x480-24x32G2S(520),
x480-48x32G2S(521),
x480-48t32G2S(522),
x8500msm48(523),
x8500g24xa(524),
x8500g48te(525),
x8500g48tePoE(526),
x460-24t(527),
x460-24p(528),
x460-24x(529),
x460-48t(530),
x460-48p(531),
x460-48x(532),
x450e-24t(533),
x450e-48t(534),
hm-2x24ga(535),
xcm88s1(536),
xcm8848t(537),
xcm88p(538),
xcm8824f(539),
xcm8808x(540),
xcm888f(541),
x480-48x20G2S(542),
x480-48t20G2S(543),
x670-48x(546),
x670v-48x(547),
e4g-400(548),
bdx-mm1(549),
bdxa-10g48x(550),
bdxa-10g24x(551),
bdxa-40g24x(552),
bdxa-40g12x(553),
bdxa-fm20t(554),
bdxa-fm10t(555),
x480-24x20G2S(556),
x650-24x40G4X(557),
x650-24t40G4X(558),
x480-24x40G4X(559),
x480-48x40G4X(560),
x480-48t40G4X(561),
tenG2xc(562),
fortyG6xc(563),
e4g-200(564),
x440-8t(565),
x440-8p(566),
x440-24t(567),
x440-24p(568),
x440-48t(569),
x440-48p(570),
x440-24t-10G(571),
x440-24p-10G(572),
x440-48t-10G(573),
x440-48p-10G(574),
ags100-24t(575),
ags150-24p(576),
x670v-48t(578),
x440-L2-24t(579),
x440-L2-48t(580),
x440-24x(582),
x440-48x(583),
bdxa-10g48t(584),
x430-24t(585),
x430-48t(586),
x440-24tdc(587),
x440-48tdc(588),
x770-32q(589),
x670G2-48x-4q(590),
x670G2-72x(591),
x460G2-24t-10G4(592),
x460G2-24p-10G4(593),
x460G2-24x-10G4(594),
x460G2-48t-10G4(595),
x460G2-48p-10G4(596),
x460G2-48x-10G4(597),
bdxb-40g12x-xl(600),
bdxb-100g4x-xl(601),
x430-8p(602),
x430-24p(603),
bdxb-100g4x(604),
ctr-8440(605),
x450-G2-24t(606),
x450-G2-24p(607),
x450-G2-48t(608),
x450-G2-48p(609),
x450-G2-24t-GE4(610),
x450-G2-24p-GE4(611),
x450-G2-48t-GE4(612),
x450-G2-48p-GE4(613),
x460G2-24t-G4(614),
x460G2-24p-G4(615),
x460G2-48t-G4(616),
x460G2-48p-G4(617),
x440G2-48p-10G4(618),
x440G2-48t-10G4(619),
x440G2-48t-10G4-DC(620),
x440G2-24p-10G4(621),
x440G2-24t-10G4(622),
x440G2-24t-10G4-DC(623),
x440G2-24x-10G4(624),
x440G2-12p-10GE4(625),
x440G2-12t-10GE4(626),
x440G2-12t8fx-G4(627),
x440G2-24t-G4(628),
x440G2-24fx-G4(629),
bdxa-48t(630),
bdxa-48x(631),
bdxa-48x-0(632),
x620-16t(633),
x620-16p(634),
x620-16x(635),
x620-10x(636),
x620-8t-2x(637),
x8900msm96(638),
x870-32c(639),
x870-96x-8c(640),
x690-48t-4q-2c(644),
x690-48x-4q-2c(645),
x460-G2-16mp-32p-10GE4(646),
x460G2-24p-24hp (647),
x460G2-24t-24ht (648),
v400-24t-10GE2 (650),
v400-24p-10GE2 (651),
v400-48t-10GE4 (652),
v400-48p-10GE4 (653),
xtremeWhitebox(656), -- WHITEBOX: Generic whitebox for all platforms
x695-48y-8c(660),
x590-24t-1q-2c(661),
x590-24x-1q-2c(662),
x465-48t(663),
x465-48p(664),
x465-48w(665),
x465-24mu(666),
x465-24mu-24w(667),
x465-24w(670),
x725-48y(671),
v300-8p-2t-w(672),
v300-8p-2x(673),
v300-8t-2x(674),
v300ht-8p-2x(675),
v300ht-8t-2x(676),
x465-24xe(677),
x465-24s(678),
x435-24p-4s(679),
x435-24t-4s(680),
x435-8p-4s(681),
x435-8t-4s(682),
x435-8p-2t-w(683),
x465i-48w(684)
}
PowerValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The input power value of the switch."
SYNTAX INTEGER {
v110 (1),
v220 (2),
v48DC (3),
unknown(4)
}
-- TODO : UnitMultiplier is copied from draft http://tools.ietf.org/html/draft-claise-energy-monitoring-mib-08
-- If the Mib is standardised please remove the below UnitMultiplier and export from the above MIB.
UnitMultiplier ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Unit Multiplier is an integer value that represents
the IEEE 61850 Annex A units multiplier associated with
the integer units used to measure the power or energy.
For example, when used with pmPowerUnitMultiplier, -3
represents 10^-3 or milliwatts."
REFERENCE
"The International System of Units (SI),
National Institute of Standards and Technology,
Spec. Publ. 330, August 1991."
SYNTAX INTEGER {
yocto(-24), -- 10^-24
zepto(-21), -- 10^-21
atto(-18), -- 10^-18
femto(-15), -- 10^-15
pico(-12), -- 10^-12
nano(-9), -- 10^-9
micro(-6), -- 10^-6
milli(-3), -- 10^-3
units(0), -- 10^0
kilo(3), -- 10^3
mega(6), -- 10^6
giga(9), -- 10^9
tera(12), -- 10^12
peta(15), -- 10^15
exa(18), -- 10^18
zetta(21), -- 10^21
yotta(24) -- 10^24
}
extremeSystemCommon OBJECT IDENTIFIER
::= { extremeSystem 1 }
extremeSystemPowerUsage OBJECT IDENTIFIER
::= { extremeSystemCommon 40 }
extremeOverTemperatureAlarm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm status of overtemperature sensor in device
enclosure."
::= { extremeSystemCommon 7 }
extremeCurrentTemperature OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current temperature in degrees celcius measured inside
device enclosure."
::= { extremeSystemCommon 8 }
--
-- Table of operational status of all internal Fans
--
extremeFanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of operational status of all internal cooling fans."
::= { extremeSystemCommon 9 }
extremeFanStatusEntry OBJECT-TYPE
SYNTAX ExtremeFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in table of all internal cooling fans."
INDEX { extremeFanNumber }
::= { extremeFanStatusTable 1 }
ExtremeFanStatusEntry ::=
SEQUENCE {
extremeFanNumber Integer32,
extremeFanOperational TruthValue,
extremeFanEntPhysicalIndex Integer32,
extremeFanSpeed Integer32
}
extremeFanNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifier of cooling fan, numbered from the front and/or
left side of device."
::= { extremeFanStatusEntry 1 }
extremeFanOperational OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operational status of a cooling fan."
::= { extremeFanStatusEntry 2 }
extremeFanEntPhysicalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entity index for this fan entity in the entityPhysicalTable table of the
entity MIB."
::= { extremeFanStatusEntry 3 }
extremeFanSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The speed (RPM) of a cooling fan in the fantray."
::= { extremeFanStatusEntry 4 }
extremePrimaryPowerOperational OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operational status of internal power supply of a device."
::= { extremeSystemCommon 10 }
extremeRedundantPowerStatus OBJECT-TYPE
SYNTAX INTEGER { notPresent(1), presentOK(2), presentNotOK(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operational status of an external redundant power supply to a device."
::= { extremeSystemCommon 11 }
extremeRedundantPowerAlarm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm state of an external redundant power supply to a device.
Alarm state indicates either fan failure or overtemperature
condition."
::= { extremeSystemCommon 12 }
extremePrimarySoftwareRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software revision of the primary image stored in
this device. This string will have a zero length if
the revision is unknown, invalid or not present. This
will also be reported in RMON2 probeSoftwareRev if this
is the software image currently running in the device."
::= { extremeSystemCommon 13 }
extremeSecondarySoftwareRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software revision of the secondary image stored in
this device. This string will have a zero length if
the revision is unknown, invalid or not present. This
will also be reported in RMON2 probeSoftwareRev if this
is the software image currently running in the device."
::= { extremeSystemCommon 14 }
extremeImageToUseOnReboot OBJECT-TYPE
SYNTAX INTEGER { primary(1), secondary(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which image will be used
on next reboot."
::= { extremeSystemCommon 15 }
extremeSystemID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..126))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents the System ID of the Summit Switch."
::= { extremeSystemCommon 16 }
extremeSystemBoardID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..126))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents the Board ID of the Summit Switch."
::= { extremeSystemCommon 17 }
extremeSystemLeftBoardID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..126))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents the Left Board ID of the Summit Switch."
::= { extremeSystemCommon 18 }
extremeSystemRightBoardID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..126))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This represents the Right Board ID of the Summit Switch."
::= { extremeSystemCommon 19 }
-- Add variables to report power supply data
extremeInputPowerVoltage OBJECT-TYPE
SYNTAX PowerValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The input power voltage at which the system is currently operating."
::= { extremeSystemCommon 20 }
extremePowerStatus OBJECT-TYPE
SYNTAX INTEGER { notPresent(1), presentOK(2), presentNotOK(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operational status of the power supply to a device."
::= { extremeSystemCommon 21 }
extremePowerAlarm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm state of the power supply to a device.
Alarm state indicates either fan failure or overtemperature
condition."
::= { extremeSystemCommon 22 }
extremeRmonEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this to true will cause the agent to
start collecting RMON statistics."
::= { extremeSystemCommon 23 }
-- OID extremeSystemCommon.24 has been deprecated and extremeCpuTasktable
-- has been moved to extremeSystemCommon.29 with new name extremeCpuTask2table
extremeBootROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software revision of the bootrom on the device.
This string will have a zero length if the revision is
unknown or invalid."
::= { extremeSystemCommon 25 }
extremeDot1dTpFdbTableEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Setting this to true will cause GetNext operations on the dot1dTpFdbTable to be allowed. Note that Get operations are always allowed."
::= { extremeSystemCommon 26 }
extremePowerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremePowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of status of all power supplies in the system."
::= { extremeSystemCommon 27 }
extremePowerSupplyEntry OBJECT-TYPE
SYNTAX ExtremePowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry indicating the status of a specific power supply."
INDEX { extremePowerSupplyNumber }
::= { extremePowerSupplyTable 1 }
ExtremePowerSupplyEntry ::=
SEQUENCE {
extremePowerSupplyNumber Integer32,
extremePowerSupplyStatus INTEGER,
extremePowerSupplyInputVoltage PowerValue,
extremePowerSupplySerialNumber DisplayString,
extremePowerSupplyEntPhysicalIndex Integer32,
extremePowerSupplyFan1Speed INTEGER,
extremePowerSupplyFan2Speed INTEGER,
extremePowerSupplySource INTEGER,
extremePowerSupplyInputPowerUsage Integer32,
extremePowerMonSupplyNumOutput Integer32,
extremePowerSupplyInputPowerUsageUnitMultiplier UnitMultiplier
}
extremePowerSupplyNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power supply number."
::= { extremePowerSupplyEntry 1 }
extremePowerSupplyStatus OBJECT-TYPE
SYNTAX INTEGER { notPresent(1), presentOK(2), presentNotOK(3), presentPowerOff(4)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the power supply."
::= { extremePowerSupplyEntry 2 }
extremePowerSupplyInputVoltage OBJECT-TYPE
SYNTAX PowerValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input voltage of the power supply"
::= { extremePowerSupplyEntry 3 }
extremePowerSupplySerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..126))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The serial number of the power supply unit."
::= { extremePowerSupplyEntry 4 }
extremePowerSupplyEntPhysicalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The entity index for this psu entity in the entityPhysicalTable
of the entity MIB."
::= { extremePowerSupplyEntry 5 }
extremePowerSupplyFan1Speed OBJECT-TYPE
SYNTAX INTEGER { notPresent(-1), noRPMInfo(-2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The speed (RPM) of Fan-1 in the power supply unit."
::= { extremePowerSupplyEntry 6 }
extremePowerSupplyFan2Speed OBJECT-TYPE
SYNTAX INTEGER { notPresent(-1), noRPMInfo(-2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The speed (RPM) of Fan-2 in the power supply unit."
::= { extremePowerSupplyEntry 7 }
extremePowerSupplySource OBJECT-TYPE
SYNTAX INTEGER { unknown(1),
ac(2),
dc(3),
externalPowerSupply(4),
internalRedundant(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The power supply unit input source."
::= { extremePowerSupplyEntry 8 }
extremePowerSupplyInputPowerUsage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Input power usage for the given psu slot. The value 0 in this field indicate the power usage is not supported or read failure."
::= { extremePowerSupplyEntry 9 }
extremePowerMonSupplyNumOutput OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of output sensors in the power supply unit"
::= { extremePowerSupplyEntry 10 }
extremePowerSupplyInputPowerUsageUnitMultiplier OBJECT-TYPE
SYNTAX UnitMultiplier
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The magnitude of watts for the usage value in extremePowerSupplyInputPowerUsage."
::= { extremePowerSupplyEntry 11 }
extremeCpuAggregateUtilization OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The aggregate CPU utilization since
the time the start started executing."
::= { extremeSystemCommon 28 }
--
-- The CPU Task table lists all executing tasks
--
extremeCpuTask2Table OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeCpuTask2Entry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table of CPU tasks that are active."
::= { extremeSystemCommon 29 }
extremeCpuTask2Entry OBJECT-TYPE
SYNTAX ExtremeCpuTask2Entry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry in table of describes a single task."
INDEX { extremeCpuTask2CpuId, extremeCpuTask2Name }
::= { extremeCpuTask2Table 1 }
ExtremeCpuTask2Entry ::=
SEQUENCE {
extremeCpuTask2CpuId
Unsigned32,
extremeCpuTask2Name
DisplayString,
extremeCpuTask2Id
Unsigned32,
extremeCpuTask2Pc
Unsigned32,
extremeCpuTask2Status
DisplayString,
extremeCpuTask2Utilization
Unsigned32,
extremeCpuTask2MaxUtilization
Unsigned32
}
extremeCpuTask2CpuId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"CPU on which this task last executed or is executing.
The primary CPU has a value of 1."
::= { extremeCpuTask2Entry 1 }
extremeCpuTask2Name OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Name associated with the reported task id."
::= { extremeCpuTask2Entry 2 }
extremeCpuTask2Id OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Task identifier assigned by the operating system when
this task is spawned."
::= { extremeCpuTask2Entry 3 }
extremeCpuTask2Pc OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The value of the program counter for this task.
It indicates the address of the next instruction
that would be executed once the operating system
resumes this task."
::= { extremeCpuTask2Entry 4 }
extremeCpuTask2Status OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The current status of the task as reported by the
operating system."
::= { extremeCpuTask2Entry 5 }
extremeCpuTask2Utilization OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The current CPU utilization by this task. This
is the utilization when the task last executed."
::= { extremeCpuTask2Entry 6 }
extremeCpuTask2MaxUtilization OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The maximum CPU utilization by this task since
the time the start started executing. This value
may be cleared."
::= { extremeCpuTask2Entry 7 }
-- This object is included in an authentication failure trap.
-- The value of this object shall be valid only if the SNMP message
-- that failed authentication used IPv4 as the network protocol.
-- For all other protocols the value of this object shall be 0 in the
-- authentication failure trap.
extremeAuthFailSrcAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS accessible-for-notify
STATUS deprecated
DESCRIPTION
"The IP address of the originator of the bad SNMP
request that caused the generation of an authentication
failure trap."
::= { extremeSystemCommon 30 }
extremeCpuTransmitPriority OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
high(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The CPU transmit priority."
::= { extremeSystemCommon 31 }
extremeImageBooted OBJECT-TYPE
SYNTAX INTEGER { primary(1), secondary(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The image with which the switch was last booted, using which it is currently running."
::= { extremeSystemCommon 32 }
extremeMsmFailoverCause OBJECT-TYPE
SYNTAX INTEGER { never(1),
admin(2),
exception(3),
removal(4),
hwFailure(5),
watchdog(6),
keepalive(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cause of the last MSM failover. never(1) means an
MSM Failover has not occurred since the last reboot.
admin(2) means the failover was initiated by the user.
exception(3) means the former master MSM encountered a
software exception condition. removal(4) means the master
MSM was physically removed from the chassis. hwFailure(5)
means a diagnostic failure was detected in the master MSM.
watchdog(6) means that the master MSM hardware watchdog
timer expired. keepalive(7) means the master MSM failed to
respond to slave keepalive requests. The MSM failover will
have been hitless only in the admin(2) and exception(3)
cases "
::= { extremeSystemCommon 33 }
extremeImageTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeImageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about each software image."
::= { extremeSystemCommon 34 }
extremeImageEntry OBJECT-TYPE
SYNTAX ExtremeImageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing information about each software image."
INDEX { extremeImageNumber }
::= { extremeImageTable 1 }
ExtremeImageEntry ::= SEQUENCE {
extremeImageNumber INTEGER,
extremeMajorVersion Integer32,
extremeSubMajorVersion Integer32,
extremeMinorVersion Integer32,
extremeBuildNumber Integer32,
extremeTechnologyReleaseNumber Integer32,
extremeSustainingReleaseNumber Integer32,
extremeBranchRevisionNumber Integer32,
extremeImageType INTEGER,
extremeImageDescription DisplayString,
extremeImageSecurity INTEGER,
extremePatchVersion Integer32
}
extremeImageNumber OBJECT-TYPE
SYNTAX INTEGER {
cur(0),
pri(1),
sec(2),
curr(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique integer identifying the particular software
image."
::= { extremeImageEntry 1 }
extremeMajorVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ExtremeWare Release Major Version."
::= { extremeImageEntry 2 }
extremeSubMajorVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The ExtremeWare Release Sub-major Version."
::= { extremeImageEntry 3 }
extremeMinorVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ExtremeWare Release Minor Version."
::= { extremeImageEntry 4 }
extremeBuildNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ExtremeWare Build Number."
::= { extremeImageEntry 5 }
extremeTechnologyReleaseNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Technology Release version. This value is zero for
all but TR releases."
::= { extremeImageEntry 6 }
extremeSustainingReleaseNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Sustaining Release number for the ExtremeWare version."
::= { extremeImageEntry 7 }
extremeBranchRevisionNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The incremental build on specified branch."
::= { extremeImageEntry 8 }
extremeImageType OBJECT-TYPE
SYNTAX INTEGER {
trunk(0),
branch(1),
patch(2),
technology(3),
beta(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The branch type from which the image was built."
::= { extremeImageEntry 9 }
extremeImageDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique string that can be used to identify the specific patch,
technology, or development branch release."
::= { extremeImageEntry 10 }
extremeImageSecurity OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
nossh(1),
ssh(2)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Indicates whether image was built with ssh. This object
is deprecated, the ssh capability can be obtained from
the extremeImageSshCapability of the ImageFeatureTable"
::= { extremeImageEntry 11 }
extremePatchVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ExtremeWare Release Patch Version."
::= { extremeImageEntry 12 }
extremeImageFeatureTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeImageFeatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about the software features."
::= { extremeSystemCommon 35 }
extremeImageFeatureEntry OBJECT-TYPE
SYNTAX ExtremeImageFeatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing information about software features."
INDEX { extremeImageFeatureNumber }
::= { extremeImageFeatureTable 1 }
ExtremeImageFeatureEntry ::= SEQUENCE {
extremeImageFeatureNumber INTEGER,
extremeImageSshCapability INTEGER,
extremeImageUAACapability INTEGER
}
extremeImageFeatureNumber OBJECT-TYPE
SYNTAX INTEGER {
cur(0),
pri(1),
sec(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique integer identifying the particular software
image."
::= { extremeImageFeatureEntry 1 }
extremeImageSshCapability OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
nossh(1),
ssh(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether image has ssh capability."
::= { extremeImageFeatureEntry 2 }
extremeImageUAACapability OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
nouaa(1),
uaa(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether image has Wireless(UAA) components."
::= { extremeImageFeatureEntry 3 }
extremeSystemPowerState OBJECT-TYPE
SYNTAX INTEGER {
computing(1),
sufficientButNotRedundantPower(2),
redundantPowerAvailable(3),
insufficientPower(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of power available."
::= { extremeSystemCommon 36 }
extremeBootTime OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The boot time expressed in standard time_t value.
When interpreted as an absolute time value, it
represents the number of seconds elapsed since 00:00:00
on January 1, 1970, Coordinated Universal Time (UTC)"
::= {extremeSystemCommon 37}
extremePowerSupplyOutputPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremePowerSupplyOutputPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The output power supply table per power supply unit."
::= { extremeSystemCommon 38 }
extremePowerSupplyOutputPowerEntry OBJECT-TYPE
SYNTAX ExtremePowerSupplyOutputPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the power supply output table."
INDEX { extremePowerSupplyIndex, extremePowerSupplyOutputSensorIdx }
::= { extremePowerSupplyOutputPowerTable 1 }
ExtremePowerSupplyOutputPowerEntry ::=
SEQUENCE {
extremePowerSupplyIndex Integer32,
extremePowerSupplyOutputSensorIdx Integer32,
extremePowerSupplyOutputVoltage Integer32,
extremePowerSupplyOutputCurrent Integer32,
extremePowerSupplyOutputUnitMultiplier UnitMultiplier
}
extremePowerSupplyIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power supply unit slot index"
::= { extremePowerSupplyOutputPowerEntry 1 }
extremePowerSupplyOutputSensorIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power supply Sensor Index"
::= { extremePowerSupplyOutputPowerEntry 2 }
extremePowerSupplyOutputVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output voltage per sensor for the current psu slot no.
0 in this field tells the psu doesnt support output voltage reading or output voltage read error."
::= { extremePowerSupplyOutputPowerEntry 3 }
extremePowerSupplyOutputCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output current per sensor for the current psu slot no.
0 in this field tells the psu doesnt support output current reading or output current read error."
::= { extremePowerSupplyOutputPowerEntry 4 }
extremePowerSupplyOutputUnitMultiplier OBJECT-TYPE
SYNTAX UnitMultiplier
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The magnitude of volts and amps for the usage value in extremePowerSupplyOutputVoltage and
extremePowerSupplyOutputCurrent."
::= { extremePowerSupplyOutputPowerEntry 5 }
extremePowerSupplyUsageTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremePowerSupplyUsageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The power supply usage on each slot."
::= { extremeSystemCommon 39 }
extremePowerSupplyUsageEntry OBJECT-TYPE
SYNTAX ExtremePowerSupplyUsageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the power supply usage table."
INDEX { extremeSlotIndex }
::= { extremePowerSupplyUsageTable 1 }
ExtremePowerSupplyUsageEntry ::=
SEQUENCE {
extremeSlotIndex Integer32,
extremePowerSupplyUsageValue Integer32,
extremePowerSupplyUnitMultiplier UnitMultiplier
}
extremeSlotIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number in the chassis/stack based system."
::= { extremePowerSupplyUsageEntry 1 }
extremePowerSupplyUsageValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power Usage of the particular slot in the chassis or stack.The power usage is measured in milli-watts."
::= { extremePowerSupplyUsageEntry 2 }
extremePowerSupplyUnitMultiplier OBJECT-TYPE
SYNTAX UnitMultiplier
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The magnitude of watts for the usage value in extremePowerSupplyUsageValue."
::= { extremePowerSupplyUsageEntry 3 }
extremeSystemPowerUsageValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current power usage of the system.In stack mode this variables tells total power usage
of the entire system."
::= { extremeSystemPowerUsage 1 }
extremeSystemPowerUsageUnitMultiplier OBJECT-TYPE
SYNTAX UnitMultiplier
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The magnitude of watts for the usage value in extremeSystemPowerUsageValue."
::= { extremeSystemPowerUsage 2 }
extremeSystemPowerMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeSystemPowerMonitorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The output power supply table per power supply unit."
::= { extremeSystemCommon 41 }
extremeSystemPowerMonitorEntry OBJECT-TYPE
SYNTAX ExtremeSystemPowerMonitorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the power supply output table."
INDEX { extremeSystemPowerMonitorIndex1 }
::= { extremeSystemPowerMonitorTable 1 }
ExtremeSystemPowerMonitorEntry ::=
SEQUENCE {
extremeSystemPowerMonitorIndex1 Integer32,
extremeSystemPowerMonitorPollInterval INTEGER,
extremeSystemPowerMonitorReportChanges INTEGER,
extremeSystemPowerMonitorChangeThreshold Integer32
}
extremeSystemPowerMonitorIndex1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reserved can be used for future expansion. currently set to zero."
::= { extremeSystemPowerMonitorEntry 1 }
extremeSystemPowerMonitorPollInterval OBJECT-TYPE
SYNTAX INTEGER (0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure how often input power is measured. it is configured in seconds. default value is 60 seconds.
if 0 is configured then the input power measurement is disabled"
::= { extremeSystemPowerMonitorEntry 2 }
extremeSystemPowerMonitorReportChanges OBJECT-TYPE
SYNTAX INTEGER {
none(1),
log(2),
trap(3),
logandtrap(4)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"configure report-changes has none or log or trap or log-and-trap, by default none is configured"
::= { extremeSystemPowerMonitorEntry 3 }
extremeSystemPowerMonitorChangeThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"configure input power change-threshold to initiate report-changes action.
By default 2 watts is configured, this field is configured in watts. "
::= { extremeSystemPowerMonitorEntry 4 }
---
--- Reboot Time Control Table Objects
---
extremeRebootTable OBJECT-TYPE
SYNTAX SEQUENCE OF RebootTimeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This group of objects use to initiate a device reboot or
contain details of the last reboot operation of the switch
modules or nodes."
::= { extremeSystemCommon 42 }
rebootTimeEntry OBJECT-TYPE
SYNTAX RebootTimeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This group of objects use to initiate a device reboot or
contain details of the last reboot operation of the switch
modules or nodes."
INDEX { extremeRebootSlotId }
::= { extremeRebootTable 1 }
RebootTimeEntry ::=
SEQUENCE {
extremeRebootSlotId
INTEGER,
extremeRebootNodeAddress
MacAddress,
extremeRebootModuleSlotId
DisplayString,
extremeRebootSlotNumber
INTEGER,
extremeRebootAsStandby
INTEGER,
extremeRebootStackTopology
INTEGER,
extremeRebootMonth
INTEGER,
extremeRebootDay
INTEGER,
extremeRebootYear
INTEGER,
extremeRebootHour
INTEGER,
extremeRebootMinute
INTEGER,
extremeRebootSeconds
INTEGER,
extremeRebootCancel
INTEGER,
extremeRebootImmediate
INTEGER,
extremeRebootRowStatus
RowStatus
}
extremeRebootSlotId OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the MSM/MM module number of a switch or the slot number currently being
used by the active stack node."
::= { rebootTimeEntry 1 }
extremeRebootNodeAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the MAC address of the SummitStack node to be rebooted.
NOTE: This object is valid only for Summit X250e and X450
series switches, and SummitStack."
::= { rebootTimeEntry 2 }
extremeRebootModuleSlotId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies A or B for an MSM/MM module.
- A specifies the MSM/MM installed in slot A.
- B specifies the MSM/MM installed in slot B.
Note: The modules that can be rebooted are management switch fabric
modules(MSM) and management modules(MM). This object is valid only
on modular switches."
::= { rebootTimeEntry 3 }
extremeRebootSlotNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the slot number currently being used by the active stack
node that is to be rebooted.
Note: This variable is available only on SummitStack."
::= { rebootTimeEntry 4 }
extremeRebootAsStandby OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies that all stack nodes that are to be rebooted
are to operate as if configured to not be master-capable.
NOTE: This object is valid only for Summit X250e
and X450 series switches and SummitStack."
::= { rebootTimeEntry 5 }
extremeRebootStackTopology OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies that the entire SummitStack is to be rebooted
whether or not nodes are active.
NOTE: This object is valid only for Summit X250e and
X450 series switches and SummitStack. "
::= { rebootTimeEntry 6 }
extremeRebootMonth OBJECT-TYPE
SYNTAX INTEGER (1..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the month that the reboot is scheduled to start."
::= { rebootTimeEntry 7 }
extremeRebootDay OBJECT-TYPE
SYNTAX INTEGER (1..31)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the day that the reboot is scheduled to start."
::= { rebootTimeEntry 8 }
extremeRebootYear OBJECT-TYPE
SYNTAX INTEGER (2003..2036)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the year that the reboot is scheduled to start."
::= { rebootTimeEntry 9 }
extremeRebootHour OBJECT-TYPE
SYNTAX INTEGER (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the hour that the reboot is scheduled to start."
::= { rebootTimeEntry 10 }
extremeRebootMinute OBJECT-TYPE
SYNTAX INTEGER (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the number of minutes that the reboot is scheduled to start."
::= { rebootTimeEntry 11 }
extremeRebootSeconds OBJECT-TYPE
SYNTAX INTEGER (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the number of seconds that the reboot is scheduled to start."
::= { rebootTimeEntry 12 }
extremeRebootCancel OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Cancels a previously scheduled reboot.
Note: This object, when enabled, override all objects associated with
a reboot request."
::= { rebootTimeEntry 13 }
extremeRebootImmediate OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates that a reboot should be executed on the target device immediately."
::= { rebootTimeEntry 14 }
extremeRebootRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The existence state of this reboot request. This object
follows the row status behavior."
::= { rebootTimeEntry 15 }
-- The Download Image Data Structure contains information
-- regarding the current state of EXOS image down load requests.
extremeDownloadImageTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeDownloadImageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This group of objects contain details of the last
or the current download image operation of the switch
modules or nodes."
::= { extremeSystemCommon 43 }
extremeDownloadImageEntry OBJECT-TYPE
SYNTAX ExtremeDownloadImageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This group of objects contain details of the last
or the current download image operation of one of the switch
modules or nodes."
INDEX { extremeDownloadImageSlotId }
::= { extremeDownloadImageTable 1 }
ExtremeDownloadImageEntry ::=
SEQUENCE {
extremeDownloadImageSlotId
INTEGER,
extremeDownloadImageStatus
INTEGER,
extremeDownloadImageFilename
DisplayString,
extremeDownloadImagePartition
INTEGER,
extremeDownloadImageHostName
DisplayString,
extremeDownloadImageIpaddress
DisplayString,
extremeDownloadImageStartTime
DisplayString,
extremeDownloadImageMemorycard
INTEGER,
extremeDownloadImageInstall
INTEGER,
extremeDownloadSlotNumber
INTEGER,
extremeDownloadModuleSlotId
DisplayString,
extremeDownloadRowStatus
RowStatus,
extremeDownloadBlockSize
INTEGER
}
extremeDownloadImageSlotId OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the MSM/MM module number of a switch or the slot number currently being
used by the active stack node."
DEFVAL { 0 }
::= { extremeDownloadImageEntry 1 }
extremeDownloadImageStatus OBJECT-TYPE
SYNTAX INTEGER {
downloadInProgress(1),
downloadOperationSuccess(2),
downloadNotPrimary(3),
downloadNameLengthError(4),
downloadInvalidFileType(5),
downloadActivePartitionError(6),
downloadIllegalHostname(7),
downloadFailed(8),
downloadInvalidIpaddr(9),
downloadMemAllocFailed(10),
downloadNotInActiveTop(11),
downloadMissingFileName(12),
downloadIllegalFileName(13),
downloadOperationTimeout(14),
downloadInvalidRowStatus(15)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the status of the current down load operation."
::= { extremeDownloadImageEntry 2 }
extremeDownloadImageFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the file name of the downloading EXOS image."
::= { extremeDownloadImageEntry 3 }
extremeDownloadImagePartition OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies which partition the image should be saved
to primary or secondary. Select primary to save the
image to the primary partition and secondary to save
the image to the secondary partition.
Note: Beginning with ExtremeXOS 12.1, an ExtremeXOS core
image must be installed on the alternate (nonactive)
partition. If a user tries to install on an active partition,
the error message [Error: Image can only be installed
to the non-active partition.] is displayed."
::= { extremeDownloadImageEntry 4 }
extremeDownloadImageHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the hostname of the TFTP server from which the
image should be obtained."
::= { extremeDownloadImageEntry 5 }
extremeDownloadImageIpaddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the IP address of the TFTP server from which the
image should be obtained."
::= { extremeDownloadImageEntry 6 }
extremeDownloadImageStartTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the start time (date and time) of the current down load operation."
::= { extremeDownloadImageEntry 7 }
extremeDownloadImageMemorycard OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(0)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies that the image should be obtained from a removable
storage device, which can be a compact flash card or a USB 2.0
storage device."
::= { extremeDownloadImageEntry 8 }
extremeDownloadImageInstall OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(0)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies to start the install process after the successful download of
the image."
::= { extremeDownloadImageEntry 9 }
extremeDownloadSlotNumber OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the slot number currently being used by the active stack
node that is to be rebooted.
Note: This variable is available only on stackable switches in a stack."
::= { extremeDownloadImageEntry 10 }
extremeDownloadModuleSlotId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies A or B for an MSM/MM module.
- A specifies the MSM/MM installed in slot A.
- B specifies the MSM/MM installed in slot B.
Note: The modules that can be rebooted are management switch fabric
modules(MSM) and management modules(MM). This object is valid only
on modular switches."
::= { extremeDownloadImageEntry 11 }
extremeDownloadRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The existence state of this download image request. This object
follows the row status behavior."
::= { extremeDownloadImageEntry 12 }
extremeDownloadBlockSize OBJECT-TYPE
SYNTAX INTEGER (24..65000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the TFTP block-size to download image from the server"
DEFVAL { 1400 }
::= { extremeDownloadImageEntry 13}
-- The Install Image Data Structure contains information
-- regarding the current state of EXOS image install requests.
extremeInstallImageTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeInstallImageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This group of objects contain details of the last
or the current install image operation of the switch
modules or nodes."
::= { extremeSystemCommon 44 }
extremeInstallImageEntry OBJECT-TYPE
SYNTAX ExtremeInstallImageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This group of objects contain details of the last
or the current install image operation of one of the switch
modules or nodes."
INDEX { extremeInstallImageSlotId }
::= { extremeInstallImageTable 1 }
ExtremeInstallImageEntry ::=
SEQUENCE {
extremeInstallImageSlotId
INTEGER,
extremeInstallImageStatus
INTEGER,
extremeInstallImageFilename
DisplayString,
extremeInstallImagePartition
INTEGER,
extremeInstallImageStartTime
DisplayString,
extremeInstallImageReboot
INTEGER,
extremeInstallImageModuleSlotId
DisplayString,
extremeInstallImageSlotNumber
INTEGER,
extremeInstallImageRowStatus
RowStatus
}
extremeInstallImageSlotId OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the MSM/MM module number of a switch or the slot number currently being
used by the active stack node."
DEFVAL { 0 }
::= { extremeInstallImageEntry 1 }
extremeInstallImageStatus OBJECT-TYPE
SYNTAX INTEGER {
installInProgress(1),
installOperationSuccess(2),
installOperationPending(3),
installNameLengthError(4),
installInvalidFileType(5),
installActivePartitionError(6),
installDwnloadSlotMismatch(7),
installFailed(8),
installNotPrimary(9),
installMemAllocFailed(10),
installNotInActiveTop(11),
installMissingFileName(12),
installIllegalFileName(13),
installOperationTimeout(14),
installOperBackupTimeout(15),
installInvalidRowStatus(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the status of the current install image operation."
::= { extremeInstallImageEntry 2 }
extremeInstallImageFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the software image file."
::= { extremeInstallImageEntry 3 }
extremeInstallImagePartition OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies which partition the image should be saved
to: primary or secondary. Select primary to save the
image to the primary partition and secondary to save
the image to the secondary partition.
Note: Beginning with ExtremeXOS 12.1, an ExtremeXOS core
image must be installed on the alternate (nonactive)
partition. If a user tries to install on an active partition,
the error message [Error: Image can only be installed
to the non-active partition.] is displayed."
::= { extremeInstallImageEntry 4 }
extremeInstallImageStartTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the start time of the current install operation."
::= { extremeInstallImageEntry 5 }
extremeInstallImageReboot OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies to reboot the switch after the image is installed."
::= { extremeInstallImageEntry 6 }
extremeInstallImageModuleSlotId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies A or B for an MSM/MM module.
- A specifies the MSM/MM installed in slot A.
- B specifies the MSM/MM installed in slot B.
Note: The modules that can be rebooted are management switch fabric
modules(MSM) and management modules(MM). This object is valid only
on modular switches."
::= { extremeInstallImageEntry 7 }
extremeInstallImageSlotNumber OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the slot number currently being used by the active stack
node that is to be rebooted.
Note: This variable is available only on stackable switches in a stack."
::= { extremeInstallImageEntry 8 }
extremeInstallImageRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The existence state of this install image request. This object
follows the row status behavior."
::= { extremeInstallImageEntry 9 }
--
-- Trap Support Objects.
--
extremeLoadInstallTrap OBJECT IDENTIFIER
::= { extremeSystemCommon 45 }
-- The following are support objects for the Configuration Management traps.
loadInstallControl OBJECT IDENTIFIER ::= { extremeLoadInstallTrap 1 }
loadInstallTraps OBJECT IDENTIFIER ::= { extremeLoadInstallTrap 2 }
downloadImageTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates whether the system produces the
downloadImageTrap notification. A no(2) value will prevent
notifications from being generated by this system."
::= { loadInstallControl 1 }
installImageTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates whether the system produces the
extremeInstallImageTrap notification. A no(2) value will prevent
notifications from being generated by this system."
::= { loadInstallControl 2 }
downloadImageTrap NOTIFICATION-TYPE
OBJECTS {
extremeDownloadImageSlotId,
extremeDownloadImageStatus,
extremeDownloadImageFilename,
extremeDownloadImagePartition,
extremeDownloadImageStartTime
}
STATUS current
DESCRIPTION
"This notification indicates the status of the last/current
download operation."
::= { loadInstallTraps 1 }
installImageTrap NOTIFICATION-TYPE
OBJECTS {
extremeInstallImageSlotId,
extremeInstallImageStatus,
extremeInstallImageFilename,
extremeInstallImagePartition,
extremeInstallImageStartTime
}
STATUS current
DESCRIPTION
"This notification indicates the status of the last/current
install operation."
::= { loadInstallTraps 2 }
-- This object shall be present in an authentication failure trap.
extremeAuthFailSrcAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object indicates the address type of the
address contained in extremeAuthFailSrcAddr."
::= { extremeSystemCommon 50 }
-- This object shall be present in an authentication failure trap.
extremeAuthFailSrcAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The address of the originator of the SNMP message that
could not be authenticated."
::= { extremeSystemCommon 51 }
-- This object shall be present in an authentication failure trap.
extremeAuthFailSrcAddressVrName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The VR from which the SNMP message that could
not be authenticated was received from."
::= { extremeSystemCommon 52 }
---------------------------------------------------------------------------
-- Objects specific to Chassis products
extremeChassisGroup OBJECT IDENTIFIER ::= { extremeSystem 2}
extremeMasterMSMSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The extremeSlotNumber of the master MSM module."
::= { extremeChassisGroup 1 }
extremeChassisPortsPerSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of ports that can be accomodated
in a single slot. This number would change to accomodate
blades with higher port density than current ones."
::= { extremeChassisGroup 3 }
extremeSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtremeSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about each slot in the
chassis."
::= { extremeChassisGroup 2 }
extremeSlotEntry OBJECT-TYPE
SYNTAX ExtremeSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing information about the module in
each slot of the chassis."
INDEX { extremeSlotNumber }
::= { extremeSlotTable 1 }
ExtremeSlotEntry ::= SEQUENCE {
extremeSlotNumber Integer32,
extremeSlotName DisplayString,
extremeSlotModuleConfiguredType INTEGER,
extremeSlotModuleInsertedType INTEGER,
extremeSlotModuleState INTEGER,
extremeSlotModuleSerialNumber DisplayString
}
extremeSlotNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique integer identifying the particular slot
in the chassis."
::= { extremeSlotEntry 1 }
extremeSlotName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A name identifying the particular slot in the chassis."
::= { extremeSlotEntry 2 }
extremeSlotModuleConfiguredType OBJECT-TYPE
SYNTAX SlotType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured module type for the given slot.
At startup, the module-type is none(1). It is
possible to configure the module-type even if there
is no module in the slot. If the current module in the
slot is different than the requested configured module-type,
then the current configuration for the module is erased and
the card will be restarted. The new configured module-type
will be recorded. Since the configured module type is different
than the actual module type, a moduleMismatch trap will be sent,
and the extremeSlotModuleState for that module will show a
mismatch(3). Setting this variable to none(1) will clear the
previously assigned module-type of this slot, and all
configuration information related to the slot will be erased."
::= { extremeSlotEntry 3 }
extremeSlotModuleInsertedType OBJECT-TYPE
SYNTAX SlotType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module type inserted into the slot. It is possible
to have a slot inserted into the slot even though
extremeSlotConfiguredType is none(1)."
::= { extremeSlotEntry 4 }
extremeSlotModuleState OBJECT-TYPE
SYNTAX INTEGER {
notPresent(1),
testing(2),
mismatch(3),
failed(4),
operational(5),
powerdown(6),
unknown(7),
present(8),
poweron(9),
post(10),
downloading(11),
booting(12),
offline(13),
initializing(14),
invalid(100)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of the module inserted in this slot."
::= { extremeSlotEntry 5 }
extremeSlotModuleSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of the module inserted in this slot."
::= { extremeSlotEntry 6 }
extremeSystemHealthCheck OBJECT IDENTIFIER
::= { extremeSystem 3 }
extremeHealthCheckErrorType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
cpuPacket(2),
backplane(3),
hardwareFail(4),
pbusChecksum(5)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The error reported in the system health check trap"
::= { extremeSystemHealthCheck 1 }
extremeHealthCheckAction OBJECT-TYPE
SYNTAX INTEGER {
syslogOnly(1),
healthCheckTrap(2),
ioModuleDown(3),
systemDown(4),
autoRecovery(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The action/alarm level configured for health check."
::= { extremeSystemHealthCheck 2 }
extremeHealthCheckMaxRetries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of times a module restart will be attempted if it fails.
If extremeHealthCheckAction is not autorecovery(5), then this value is zero."
::= { extremeSystemHealthCheck 3 }
-- ===========================================================================
extremeSystemThresholds OBJECT IDENTIFIER
::= { extremeSystem 4 }
extremeCpuUtilRisingThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Rising threshold for CPU Aggregation utilization trap"
::= { extremeSystemThresholds 1 }
extremeCpuTaskUtilPair OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS deprecated
DESCRIPTION
"TaskName/CPU_% Util pair reported in CPU Utilization trap"
::= { extremeSystemThresholds 2 }
extremeSystemNotifications OBJECT IDENTIFIER ::= { extremeSystem 6 }
extremeSystemTrapsPrefix OBJECT IDENTIFIER ::= { extremeSystemNotifications 0 }
extremeSystemPowerStatus NOTIFICATION-TYPE
OBJECTS { sysDescr, extremeSystemPowerState }
STATUS current
DESCRIPTION
"Change in status of System Power
The trap will not be generated for discovering state."
::= { extremeSystemTrapsPrefix 1 }
extremeGenericTrap NOTIFICATION-TYPE
OBJECTS {severity, eventName, message}
STATUS current
DESCRIPTION
"Some event took place in the system"
::= { extremeSystemTrapsPrefix 2 }
extremeGenericTrapParams OBJECT IDENTIFIER
::= { extremeSystem 7 }
severity OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
error(2),
warning(3),
notice(4),
info(5),
debug-summary(6),
debug-verbose(7),
debug-data(8)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The severity of the message being sent. "
::= {extremeGenericTrapParams 1}
eventName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..40))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The event name being sent."
::= {extremeGenericTrapParams 2}
message OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..256))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The message being sent"
::= {extremeGenericTrapParams 3}
extremePsuPowerStatus NOTIFICATION-TYPE
OBJECTS { sysDescr, extremePowerSupplyNumber, extremePowerSupplyStatus }
STATUS current
DESCRIPTION
"Trap to indicate change in status of Power Supply."
::= { extremeSystemTrapsPrefix 3 }
extremeSystemPowerUsageNotification NOTIFICATION-TYPE
OBJECTS { sysUpTime, sysDescr, extremeSystemPowerUsageValue, extremeSystemPowerUsageUnitMultiplier }
STATUS current
DESCRIPTION
"Whenever the power usage is increased/decreased by the configured
threshold value then the power usage trap is generated if the trap is enabled.."
::= { extremeSystemTrapsPrefix 4 }
extremeSaveConfiguration OBJECT-TYPE
SYNTAX INTEGER {
saveToPrimary(1),
saveToSecondary(2),
saveToCurrent(3),
factoryDefault(4),
saveToFile(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set, the device will copy the contents
of the configuration database to a buffer and save it to the
persistent store specified by the value of the object. The
save is performed asynchronously, and the snmp agent will
continue to respond to only gets while the save is
taking place. A network management application may use the
extremeSaveStatus object to determine when the asynchronous
save operation has completed and can respond to sets. When
this object is set to value saveToFile(5), the file name should
be indicated with the object extremeSaveConfigurationFileName.
factoryDefault(4) is a read-only value for this object."
::= { extremeSystemCommon 3 }
extremeSaveStatus OBJECT-TYPE
SYNTAX INTEGER { saveInProgress(1), saveNotInProgress(2), saveNotReady(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object will return the status of a save operation invoked
by setting the extremeSaveConfiguration object. A network
management application can read this object to determine that a
save operation has completed."
::= { extremeSystemCommon 4 }
extremeCurrentConfigInUse OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2),
other(3),
factoryDefault(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows which NVRAM configuration store was used at last boot."
::= { extremeSystemCommon 5 }
extremeConfigToUseOnReboot OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2),
other(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which NVRAM configuration store will be used
on next reboot."
::= { extremeSystemCommon 6 }
extremeSaveConfigurationFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This object is set, along the object extremSaveConfiguration
option with value 5.This object indicates the file name to be used
while saving the file. On reading it returns the current selected
config."
::= { extremeSystemCommon 48 }
extremeUseOnRebootFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This object is set, along the object extremeConfigToUseOnReboot
option with value 3.This object indicates the file name to be used
while saving the file"
::= { extremeSystemCommon 49 }
extremeAutoSave OBJECT IDENTIFIER
::= { extremeSystemCommon 53 }
extremeAutoSaveConfigurationFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This object indicates the file name to be used when configuration
is automatically saved. On reading it returns the file name currently
being used for automatic configuration saves."
::= { extremeAutoSave 1 }
extremeAutoSaveConfigurationEnabled OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable automatic configuration save. On reading it returns the current
state of automatic configuration save."
::= { extremeAutoSave 2 }
extremeAutoSaveConfigurationTimeInterval OBJECT-TYPE
SYNTAX INTEGER (2..1440)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure how often configuration is automatically saved. It is configured
in minutes."
::= { extremeAutoSave 3 }
END