mibs/MIBS/fs/GBNServiceTACACS-MIB
2023-12-05 12:25:34 +01:00

113 lines
3.5 KiB
Plaintext

GBNServiceTACACS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32, IpAddress,
NOTIFICATION-TYPE FROM SNMPv2-SMI
DisplayString, MacAddress,
RowStatus, TruthValue FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
gbnServiceAAA FROM ADMIN-MASTER-MIB
;
gbnTacacsMib MODULE-IDENTITY
LAST-UPDATED "200905270000Z" -- May 27, 2009
ORGANIZATION "QTECH LLC"
CONTACT-INFO "Basil Budko
E-mail: budko@qtech.ru"
DESCRIPTION "admin tacacs Enterprise MIB definition."
REVISION "200905270000Z" -- May 27, 2009
DESCRIPTION "Initial MIB creation."
::= { gbnServiceAAA 3 }
------------------------------------------------------------------------------
-- Textual Conventions (i.e., these do not affect object encoding):
------------------------------------------------------------------------------
--
-- "DURABLE":
-- Objects that are saved across a system reset and/or power cycle
-- are noted as "DURABLE" for convenience in the DESCRIPTION
-- section of the object definition. Code must be explicitly
-- written to implement these DURABLE objects.
--
------------------------------------------------------------------------------
-- define groups in gbn-TACACS-MIB
PriServerIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ip address of primary tacacs+ server."
::= { gbnTacacsMib 1 }
SecServerIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ip address of secondary tacacs+ server."
::= { gbnTacacsMib 2 }
PriServerKey OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"key of primary tacacs+ server."
::= { gbnTacacsMib 3 }
SecServerKey OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"key of secondary tacacs+ server."
::= { gbnTacacsMib 4 }
PriServerPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"tcp port of primary tacacs+ server, range is from 1 to 65535, default is 49."
::= { gbnTacacsMib 5 }
SecServerPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"tcp port of secondary tacacs+ server, range is from 1 to 65535, default is 49."
::= { gbnTacacsMib 6 }
PriServerTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"timeout of connection to primary tacacs+ server, range is from 1 to 70, default is 5 seconds."
::= { gbnTacacsMib 7 }
SecServerTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"timeout of connection to secondary tacacs+ server, range is from 1 to 70, default is 5 seconds."
::= { gbnTacacsMib 8 }
--
-- END of gbn-TACACS-MIB
--
END